1
|
Ömeroğlu MK, Hekimoğlu HC. Evaluation of colour stability, water sorption and solubility of no-cap flowable bulk fill resin composites. BMC Oral Health 2025; 25:604. [PMID: 40253330 PMCID: PMC12009527 DOI: 10.1186/s12903-025-05902-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2025] [Accepted: 03/28/2025] [Indexed: 04/21/2025] Open
Abstract
BACKGROUND The aim of this study is to investigate the colour stability, water absorption, and solubility values of low viscosity bulk fill resin composites that do not require an additional layer in comparison with high viscosity and low viscosity bulk fill resin composites used as a base. METHODS In the present study, four different bulk fill resin composites were used: Charisma Bulk Flow One (Kulzer), Estelite Bulk Fill Flowable (Tokuyama), X-tra Base (VOCO), Filtek One Bulk Fill (3M ESPE). The resin composites were prepared as disc-shaped samples with a diameter of 5 mm and a thickness of 4 mm, then polymerized using a LED light device (Elipar DeepCureS, 3M ESPE). The samples were kept in artificial saliva and coffee solution for 28 days to determine water absorption, solubility levels and ∆E values, with measurements taken on days 7, 14, 21 and 28. Water absorption and solubility levels were calculated based on ISO4049:2009 specification, and mean colour change values were calculated based on CIEDE2000 formula. Repeated Measures ANOVA, along with post hoc Bonferroni, Tamhane, and Adjusted Bonferroni tests, were used for the statistical evaluation of the data (p < 0.05). RESULTS Among all composite groups at all time intervals, Charisma Bulk Flow One composite showed the highest water absorption, solubility, and discolouration values. CONCLUSION The water absorption, solubility and discolouration values of the resin composites used in this study were affected by the amount of filler in the resin structure. The clinical applicability of low-viscosity bulk-fill resin composites that do not require an additional capping layer should be carefully reassessed.
Collapse
Affiliation(s)
- Merve Kütük Ömeroğlu
- Faculty of Dentistry, Department of Restorative Dentistry, Istanbul Okan University, Istanbul, Turkey.
| | | |
Collapse
|
2
|
Elkhatib AA, Elwardani GE. Changes in optical properties of aesthetic paediatric restorative materials following exposure to beverages: In-vitro study. Eur Arch Paediatr Dent 2025; 26:159-167. [PMID: 39775793 DOI: 10.1007/s40368-024-00986-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2024] [Accepted: 12/05/2024] [Indexed: 01/11/2025]
Abstract
PURPOSE Optical properties of recent aesthetic restorative materials must maintain an acceptable appearance throughout their functional lifetime. This study aimed to assess the changes in translucency and colour of recent resin-based restorative materials after exposure to beverages commonly consumed by children. METHODS An experimental in-vitro study on 48 discs specimens prepared from; Group I: Filtek Z250 XT (Nanohybrid), Group II: Cention N (Alkasite bulkfill), and Group III: SDR flow Plus (Flowable bulkfill). The prepared disc specimens were randomly assigned into 4 subgroups (n = 12) according to the immersion solution: Subgroup A (control): distilled water, B: Coca-Cola, C: chocolate milk, and D: Orange juice. Translucency and colour measurements were done before immersion (baseline) and on day 30 of exposure. Statistical analysis involved Two Way Repeated Measures ANOVA and Kruskal-Wallis test. RESULTS The statistical analysis revealed that the restorative material, immersion time, and immersion solution had a significant effect on the change in translucency (p < 0.0001*, p < 0.0001*, p = 0.001*, respectively). Regarding colour changes, different immersion solutions had a statistically significant effect on Filtek Z250 XT and Cention N (p < 0.0001*). Distilled water and Coca-Cola were found to have a significant effect on colour change for all restorative materials investigated (p < 0.0001*, p = 0.003*). CONCLUSION the optical properties of resin-based restorative materials used in paediatric dentistry were notably affected by prolonged exposure to beverages commonly consumed by children.
Collapse
Affiliation(s)
- A A Elkhatib
- Pediatric Dentistry and Dental Public Health Department, Faculty of Oral and Dental Medicine, Kafrelsheikh University, Kafrelsheikh, Egypt.
| | - G E Elwardani
- Pediatric Dentistry and Dental Public Health Department.Faculty of Dentistry, Alexandria University, Alexandria, Egypt
- Alexandria University Main Hospitals, Alexandria, Egypt
| |
Collapse
|
3
|
Kazak M, Toz Akalin T, Esen F. Comparison of Water Sorption and Water Solubility Properties of Current Restorative Materials with Different Contents. Eur J Dent 2025; 19:248-254. [PMID: 39293490 PMCID: PMC11750316 DOI: 10.1055/s-0044-1789270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/20/2024] Open
Abstract
OBJECTIVES This study aimed to investigate and compare water sorption and solubility properties of current restorative materials with different contents. MATERIALS AND METHODS Alkasite, self-adhesive restorative material (Cention N, Ivoclar Vivadent AG, Schaan, Liechtenstein), bulk-fill glass hybrid restorative material (EQUIA Forte HT, GC Corp., Tokyo, Japan), nanohybrid universal composite material (OptiShade, Kerr Dental, United States), and bulk-fill composite material (Filtek One Bulk Fill Restorative, 3M ESPE, St. Paul, Minnesota, United States) were used. Samples (n = 6) were prepared (2 × 10 mm) according to the ISO 4049 standards. Water sorption and solubility values were calculated according to the ISO 4049 standards. STATISTICAL ANALYSIS One-way ANOVA, Tukey's post-hoc, Tamhane's T2 post-hoc, Pearson's correlation, and independent samples t-tests were used for statistical analysis (p < 0.05). RESULTS Group EQUIA Forte HT significantly showed the highest water sorption values (57.278 ± 3.174), while Group Filtek One Bulk Fill Restorative exhibited the lowest (4.429 ± 0.174; p < 0.05). The water sorption values for Group Cention N were 5.000 ± 0.542. Group EQUIA Forte HT significantly had the lowest water solubility values (-99.799 ± 1.909), while Group Cention N (-2.966 ± 0.402) significantly exhibited the highest (p < 0.05). There was no significant correlation between water sorption and solubility values for each material (p > 0.05). CONCLUSION The bulk-fill nano-filled composite resin material was successful in terms of water sorption while the bulk-fill glass hybrid restorative system in terms of water solubility. Alkasite can be recommended to be used as a base material due to its high solubility feature. Monomer, filler type, and amount had an impact on the water sorption and solubility properties of the tested materials.
Collapse
Affiliation(s)
- Magrur Kazak
- Department of Restorative Dentistry, Bahcesehir University School of Dental Medicine, Istanbul, Türkiye
- Department of Therapeutic Dentistry, BAU International University School of Medicine and Health Science, Batumi, Georgia
| | - Tugba Toz Akalin
- Department of Restorative Dentistry, Istinye University Faculty of Dentistry, Istanbul, Türkiye
| | - Fevzi Esen
- Department of Health Information Systems, University of Health Sciences, Institution of Hamidiye Medical Sciences, Istanbul, Türkiye
| |
Collapse
|
4
|
Deng H, Liu F, He J. The Effect of Inorganic Filler Content on the Properties of BPA-Free Bulk-Fill Dental Resin Composites. MATERIALS (BASEL, SWITZERLAND) 2024; 17:5040. [PMID: 39459745 PMCID: PMC11509294 DOI: 10.3390/ma17205040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2024] [Revised: 10/10/2024] [Accepted: 10/14/2024] [Indexed: 10/28/2024]
Abstract
This study aimed to enhance the performance of dental resin composites (DRCs) by increasing the content of inorganic fillers while addressing potential health risks associated with Bisphenol A (BPA). To achieve this, the BPA-based resin monomer Bis-GMA was replaced with BPA-free Bis-EFMA. The study then explored the impact of varying inorganic filler contents on the physiochemical properties of Bis-EFMA-based bulk-fill dental resin composites (BF-DRCs). Four distinct Bis-EFMA-based BF-DRCs were formulated, each with different inorganic filler contents ranging from 70 wt% to 76 wt%. The study tested the depth of cure (DOC), double-bond conversion (DC), water sorption (WS), solubility (SL), and cytotoxicity of the system. It notably investigated the effects of increasing filler content on mechanical properties through flexural strength (FS), flexural modulus (FM), Vickers microhardness (VHN), and wear resistance, as well as the impact on polymerization shrinkage, including volumetric shrinkage (VS) and shrinkage stress (SS). To assess the commercial application potential of Bis-EFMA-based BF-DRC, the research used the commercially available BF-DRC Filtek Bulk-Fill Posterior (FBF) as a control. The results indicated that a higher filler content did not affect the DOC of Bis-EFMA-based BF-DRCs. Inorganic fillers at higher concentrations significantly enhanced overall mechanical properties while significantly reducing volumetric shrinkage (VS; p < 0.05). When the concentration of inorganic fillers in the resin system reached 76 wt%, most of the performance of the Bis-EFMA-based BF-DRC surpassed that of the commercial control FBF, except for FS, FM, and SS. These findings highlight the potential of Bis-EFMA-based BF-DRC as a long-term restorative material for dental applications.
Collapse
Affiliation(s)
| | | | - Jingwei He
- School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641, China; (H.D.); (F.L.)
| |
Collapse
|
5
|
Öztürk ANS, Harorli OT. Bulk-fill composite in challenging cavities: conversion rate, solubility, and water absorption analysis. Odontology 2024; 112:718-728. [PMID: 38085386 DOI: 10.1007/s10266-023-00873-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 11/06/2023] [Indexed: 07/25/2024]
Abstract
In a deep, curved cavity, polymerization of a bulk fill composite can be challenging. The aim of this study was to investigate the solubility, water absorption, and conversion rate of bulk-fill composite samples prepared using molds with various slope angles. Bulk-fill composite resin (Filtek One Bulk Fill) was placed into cylindrical Teflon molds with a depth of 4 mm, angled at varying degrees (90°, 75°, 60°, 45°). Two different LED light-curing units (VALO Cordless, iLed Curing Light) were used to cure the samples. Polymerizations were performed at three different distances (0 mm, 2 mm, and 4 mm). Five samples per group were used, resulting in a total of 24 groups. The Fourier Transform Infrared Spectrometer was utilized to evaluate the conversion levels of the samples. Water sorption and solubility values were determined by storing the composites in distilled water at 37 °C for 21 days. The VALO light-curing unit applied closest to samples inserted in a 90° angulation mold had the highest mean degree of conversion (41.55%), while iLED light-curing unit group that applied from 4 mm to the samples inserted in a 45° angulation mold had the lowest mean conversion (8.97%). The angle of the cavity and the distance at which the light-curing unit is applied significantly affected bulk-fill composite resin conversion. In addition, the choice of light-curing unit impacted the conversion levels. However, with the tested conditions, the water sorption and solubility values of polymerized composite resin samples remain unaffected by these factors.
Collapse
Affiliation(s)
- Asu Nur Sandıkçı Öztürk
- Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University, 07070, Antalya, Turkey
| | - Osman Tolga Harorli
- Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University, 07070, Antalya, Turkey.
| |
Collapse
|
6
|
Gil-Pozo A, Astudillo-Rubio D, Ferrando Cascales Á, Inchingolo F, Hirata R, Sauro S, Delgado-Gaete A. Effect of gastric acids on the mechanical properties of conventional and CAD/CAM resin composites - An in-vitro study. J Mech Behav Biomed Mater 2024; 155:106565. [PMID: 38718723 DOI: 10.1016/j.jmbbm.2024.106565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 04/29/2024] [Accepted: 04/30/2024] [Indexed: 05/28/2024]
Abstract
OBJECTIVES Dental erosion in patients with gastroesophageal reflux disease (GERD) is a current and frequent condition that may compromise the mechanical properties and clinical durability of resin-based composites (RBCs). This study assessed the mechanical properties of conventional and computer-aided design/computer-aided manufacturing (CAD/CAM) RBCs subsequent to simulated gastric acid aging. MATERIALS AND METHOD Three conventional and three CAD/CAM composites were assessed. They were divided into an experimental group (exposed to simulated gastric acid aging) and a control group (no aging). Both groups were analyzed for Vickers microhardness (VHN), wear and flexural strength over a period of six months. The failure rate probability for each RBC was calculated through the Weibull cumulative distribution function (m). Statistical analysis was conducted using repeated measures ANOVA, 3-way ANOVA, a non-parametric Kruskal-Wallis and U Mann-Whitney tests (α = 0.05). RESULTS The mechanical properties of all the RBCs dropped significantly after aging (p < 0.05). Lower VHN and flexural strength values, along with greater wear values were evident in the experimental groups, though the effects of the treatment varied between RBCs. The Weibull m of all the RBCs decreased over time. CONCLUSION Conventional RBCs might show greater reduction in mechanical properties compared to CAD/CAM RBCs when exposed to gastric acid attack. Thus, CAD/CAM composites may represent a suitable choice for the treatment of patients presenting erosive issues.
Collapse
Affiliation(s)
- Alexandra Gil-Pozo
- Division of Prosthodontics, School of Dentistry, Universidad Católica de Cuenca, 010107, Cuenca, Ecuador.
| | - Daniela Astudillo-Rubio
- Division of Prosthodontics, School of Dentistry, Universidad Católica de Cuenca, 010107, Cuenca, Ecuador.
| | - Álvaro Ferrando Cascales
- Department of Biomaterials Engineering, Faculty of Medicine, UCAM, Universidad Católica de Murcia, Campus de los Jerónimos, 135 Guadalupe, 30107, Murcia, Spain.
| | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", 70124, Bari, Italy.
| | - Ronaldo Hirata
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, 10010, USA.
| | - Salvatore Sauro
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Ciencias de la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo ss/n, Alfara del Patriarca, 46115, Valencia, Spain.
| | - Andrés Delgado-Gaete
- Division of Prosthodontics, School of Dentistry, Universidad Católica de Cuenca, 010107, Cuenca, Ecuador.
| |
Collapse
|
7
|
Bai X, Chen Y, Zhou T, Pow EHN, Tsoi JKH. The chemical and optical stability evaluation of injectable restorative materials under wet challenge. J Dent 2024; 146:105031. [PMID: 38710315 DOI: 10.1016/j.jdent.2024.105031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/08/2024] [Accepted: 04/27/2024] [Indexed: 05/08/2024] Open
Abstract
OBJECTIVES To investigate and compare the chemical and optical stability of four restorative composite materials: two injectable resins, one flowable resin and one compomer. METHODS Two injectable nano-filled composite resins: G-aenial Universal (GU) and Beautifil Injectable XSL (BI), a flowable composite resin: Filtek Supreme Flowable (FS) and a compomer: Dyract Flow (DF), in A2 shade were tested and compared. Water sorption and solubility were conducted according to ISO4049:2019 standard; ICP-OES and F-ion selective electrode were used to test the elemental release; Degree of conversion (DC) was obtained by using FTIR; water contact angle was obtained by static sessile drop method, and a spectrophotometer was used for optical properties (ΔE⁎, ΔL⁎ and TP). SPSS 28.0 was used for statistical analysis and the significant level was pre-set as α = 0.05. RESULTS GU performed the best in water sorption and solubility, FS had the lowest elemental release, the best colour stability, and the highest DCIM and DC24-h. DF, the compomer had the lowest, and GU and BI, the injectable composites had the largest water contact angle, respectively. Correlations were found between water sorption and water solubility. CONCLUSIONS The four composite restorative materials showed different chemical and optical behaviours. Overall, composite resins performed better than compomer, while additional laboratory and in vivo tests are necessary to obtain a more comprehensive comparison between injectable and flowable composite resins. Wsp and Wsl are influenced by many common factors, and the values are highly positively related. CLINICAL SIGNIFICANCE A comprehensive understanding of materials is crucial before selecting materials for clinical practice. Composite resins rather than compomers are recommended because of their exceptional properties, which make them eligible for a wide range of clinical applications and an elongated lifespan.
Collapse
Affiliation(s)
- Xuedong Bai
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Yanning Chen
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Tianyu Zhou
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Edmond Ho Nang Pow
- Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - James Kit Hon Tsoi
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China.
| |
Collapse
|
8
|
da Silva FAS, Paschoini VL, Cortez TV, Corona SAM, Souza-Gabriel AE. Physicochemical and mechanical properties of preheated composite resins for luting ceramic laminates. Odontology 2024; 112:773-781. [PMID: 38305943 DOI: 10.1007/s10266-023-00880-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Accepted: 11/28/2023] [Indexed: 02/03/2024]
Abstract
This study analyzed and compared the physicochemical and mechanical properties of preheated resin composite with light-cured resin cement for luting indirect restorations. 210 specimens of resin cement/resin composite were prepared according to preheating treatment heated (Htd) or not (NHtd). Light-cured resin cement (Variolink Veneer, Ivoclar), and resin composite (Microhybrid-Z100, 3 M; Nanohybrid-Empress direct, Ivoclar; and Bulk fill-Filtek One, 3 M) were used (n = 10). Resin cement specimens were not preheated. The response variables were (n = 10): film thickness, microhardness, liquid sorption and solubility. Data were analyzed by 2-way ANOVA and Tukey HSD post-test (α = 0.05). Bulk fill NHtd resin had the highest film thickness values (p < 0.001). Microhybrid and nanohybrid Htd resins had the smallest thicknesses and did not differ from the cement (p > 0.05). The highest microhardness values were found for Bulk fill NHtd and Bulk fill Htd resins. The nanohybrid and microhybrid Htd resins showed the lowest microhardness values, with no difference in cement (p > 0.05). For liquid sorption, there was no significant difference between the groups (p = 0.1941). The microhybrid Htd resin showed higher solubility values than the other materials (p = 0.0023), but it did not differ statistically from resin cement (p > 0.05). Preheating composite resins reduced the film thickness. After heating, nanohybrid and Bulk fill resins retained stable microhardness, sorption, and solubility values.
Collapse
Affiliation(s)
- Fabio Augusto Soares da Silva
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Av. Café S/N, Ribeirão Preto, São Paulo, 14040-904, Brazil
| | - Vitoria Leite Paschoini
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Av. Café S/N, Ribeirão Preto, São Paulo, 14040-904, Brazil.
| | - Thiago Vinicius Cortez
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Av. Café S/N, Ribeirão Preto, São Paulo, 14040-904, Brazil
| | - Silmara Aparecida Milori Corona
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Av. Café S/N, Ribeirão Preto, São Paulo, 14040-904, Brazil
| | - Aline Evangelista Souza-Gabriel
- Department of Restorative Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Av. Café S/N, Ribeirão Preto, São Paulo, 14040-904, Brazil
| |
Collapse
|
9
|
Porojan L, Toma FR, Gherban MI, Vasiliu RD, Matichescu A. Surface Topography of Thermoplastic Appliance Materials Related to Sorption and Solubility in Artificial Saliva. Biomimetics (Basel) 2024; 9:379. [PMID: 39056820 PMCID: PMC11274910 DOI: 10.3390/biomimetics9070379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 06/07/2024] [Accepted: 06/15/2024] [Indexed: 07/28/2024] Open
Abstract
(1) Background: PETG (polyethylene terephthalate glycol) is a transparent, inexpensive, and versatile thermoplastic biomaterial, and it is increasingly being used for a variety of medical applications in dentistry, orthopedics, tissue engineering, and surgery. It is known to have remarkable properties such as tensile strength, high ductility, and resistance to chemical insults and heat, but it can be affected by various environmental conditions. The aim of the present study was to evaluate the topographical characteristics of four thermoplastic dental appliance materials in relation to water sorption in simulated oral environments (artificial saliva samples with different pH values). (2) Methods: The following four types of PETG clear thermoplastic materials were selected for the present study: Leone (L), Crystal (C), Erkodur (E), and Duran (D). In relation to the desiccation and water-uptake stages, their water sorption (Wsp) and solubility (Wsl) were calculated, and the surface topographies were analyzed on two length scales. The surface roughness was determined using a contact profilometer, and nanoroughness measurements were generated by three-dimensional profiles using an atomic force microscope (AFM). Statistical analyses (one-way ANOVA and unpaired and paired Student t-tests) were performed. (3) Results: After saliva immersion, the weights of all samples increased, and the highest sorption was recorded in a basic environment. Among the materials, the water uptake for the L samples was the highest, and for E, it was the lowest. In relation to water solubility, significant values were registered for both the L and C samples' materials. After immersion and desiccation, a decreasing trend in microroughness was observed. The AFM high-resolution images reflected more irregular surfaces related to saliva immersion. (4) Conclusions: The sorption rates recorded in water-based artificial saliva were higher for basic pH levels, with significant differences between the samples. There were also significant differences related to the behaviors of the materials included in the study. In relation to roughness, on a microscale, the surfaces tended to be smoother after the saliva immersions, and on a nanoscale, they became more irregular.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| | - Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| | - Mihaela Ionela Gherban
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| | - Roxana Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| | - Anamaria Matichescu
- Department of Preventive, Community Dentistry and Oral Health, Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babes” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania;
| |
Collapse
|
10
|
Thadathil Varghese J, Raju R, Farrar P, Prentice L, Prusty BG. Comparative analysis of self-cure and dual cure-dental composites on their physico-mechanical behaviour. Aust Dent J 2024; 69:124-138. [PMID: 38131257 DOI: 10.1111/adj.13004] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/30/2023] [Indexed: 12/23/2023]
Abstract
BACKGROUND Clinical practitioners may have become familiar with the rapid transformation of dental composites. However, they may not scientifically understand the factors influencing the mechanical and physical properties. Scientific knowledge of filler-resin interaction can significantly improve clinical understanding of resin composites. Several independent studies have examined the mechanical and physico-mechanical properties of dental resin composites; however, no comprehensive study has examined the influence of fillers and resin materials on the physico-mechanical properties of both self-cure and dual-cure composites. METHODS This study performed investigations on the physico-mechanical behaviour of four commercially available dual-cure dental composites (Bioactive, Fill Up!, Surefil One, Cention N) and two commercially available self-cure dental composites (Stela Capsule and Stela Automix). Test specimens for flexural and compressive strength, microhardness, fracture toughness, and hydrolytic behaviour were prepared and tested as per respective standards. The data sets were statistically analysed using one-way ANOVA and Tukey's post-hoc comparison. RESULTS There was a substantial variation in flexural strength and modulus values in this study, ranging from 32.0 to 113.4 MPa and 2.36 to 12.07 GPa, respectively. Similarly, there were significant differences in compressive strength between the materials in this study, ranging from 119.3 to 223.5 MPa. The highest fracture toughness value was found to be 1.41 MPa.m0.5, while the lowest value was 0.43 MPa.m0.5. Variations in surface microhardness were significant (24.11-68.0 N/mm2), which correlated with the filler content. Water sorption and solubility demonstrated high variations among materials, with Surefil One exceeding ISO 4049 thresholds significantly. CONCLUSIONS A linear correlation can be established between surface microhardness (HV) and flexural and compressive moduli, as well as filler content (wt.%). However, both flexural and compressive strengths are impacted by the resin's constituent monomers and the resin-filler matrix's cross-linking capability. Additionally, factors such as filler size, shape, and the cross-linking ability of the resin-filler matrix play a crucial role in fracture toughness and the propagation of cracks within the restoration. Also, resin monomers and filler particle size affect the hydrolytic degradation characteristics of composites, which can also affect their mechanical properties. © 2023 Australian Dental Association.
Collapse
Affiliation(s)
- J Thadathil Varghese
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - R Raju
- ARC Centre for Automated Manufacture of Advanced Composites, School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales, Australia
| | - P Farrar
- SDI Limited, Bayswater, Victoria, Australia
| | - L Prentice
- SDI Limited, Bayswater, Victoria, Australia
| | - B G Prusty
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales, Australia
- ARC Centre for Automated Manufacture of Advanced Composites, School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales, Australia
- Australian Composites Manufacturing CRC Ltd. (ACM CRC), University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
11
|
Thanoon H, Silikas N, Watts DC. Effect of polymerisation protocols on water sorption, solubility and hygroscopic expansion of fast-cure bulk-fill composite. Dent Mater 2024; 40:951-957. [PMID: 38734487 DOI: 10.1016/j.dental.2024.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 04/30/2024] [Accepted: 04/30/2024] [Indexed: 05/13/2024]
Abstract
OBJECTIVE This study examines the effect of two light-curing protocols from a LED polywave light curing unit (LCU) on water sorption, solubility, and hygroscopic expansion of fast and conventional bulk-fill resin-based composites (RBCs) aged in distilled water for 120 d. METHODS Three bulk-fill RBCs materials were studied: Tetric PowerFill® (fast photo-polymerised composite) (TPF), Tetric EvoCeram bulk-fill (EVO), and GrandioSo x-tra bulk-fill (GSO) (conventional photo-polymerised composites). Specimens were prepared within a 3D-printed resin mold (8-mm diameter x 4-mm height) and light-cured from one side only with 2 modes of polywave LCU (Bluephase® PowerCure): 3 s mode and for 20 s in "Standard" mode. Water sorption and solubility were measured at fixed time intervals for 120 d of distilled water storage, then reconditioned to dry to measure desorption for 75 d, all at 37 ± 1 °C. Hygroscopic (volumetric) expansion was recorded at the same time intervals up to 120 d. Data were analysed through SPSS using Two-way ANOVA, One-way ANOVA, independent t-tests, and Tukey's post-hoc correction tests (p < 0.05). RESULTS TPF, when irradiated for 3 s demonstrated minimal water sorption (0.83%), solubility (1.01 μg/mm3), and least volumetric expansion (1.64%) compared to EVO and GSO. While EVO showed the highest water sorption (1.03%) and solubility (1.95 μg/mm3) at 3 s. GSO had the lowest sorption (0.67%) and (0.56%) in 3 s and 20 s protocols, respectively. Nevertheless, all the sorption and solubility data were within the ISO 4049 limits. SIGNIFICANCE For TPF, fast (3 s) polymerisation did not increase either water sorption or solubility, compared with 20 s irradiation. However, with the two comparative bulk-fill composites, fast cure increased water sorption by 15-25% and more than doubled solubility. These findings were consistent with the lesser volumetric expansions observed for Tetric PowerFill at both the fast and standard protocols, indicating its relative stability across polymerisation protocols.
Collapse
Affiliation(s)
- Halah Thanoon
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Department of Restorative Dentistry, College of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
| | - Nikolaos Silikas
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK
| | - David C Watts
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Photon Science Institute, University of Manchester, Manchester, UK.
| |
Collapse
|
12
|
Néma V, Kunsági-Máté S, Őri Z, Kiss T, Szabó P, Szalma J, Fráter M, Lempel E. Relation between internal adaptation and degree of conversion of short-fiber reinforced resin composites applied in bulk or layered technique in deep MOD cavities. Dent Mater 2024; 40:581-592. [PMID: 38368136 DOI: 10.1016/j.dental.2024.02.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 01/08/2024] [Accepted: 02/12/2024] [Indexed: 02/19/2024]
Abstract
OBJECTIVE The purpose was to evaluate the degree of conversion (DC), internal adaptation (IA) and closed porosity (CP) of short-fiber reinforced resin composites (SFRC) associated with layered or bulk restorative procedures in deep MOD cavities. METHODS Eighty third molars with standardized MOD cavities (5-mm-depth, 2.5-mm-width) were randomly divided into four groups and restored as follows: 1) bulk SFRC; 2) layered SFRC; 3) flowable bulk-fill resin-based composites (RBC); 4) layered conventional RBC. After one-month wet storage the samples were subjected to micro-computed tomography measurements and scanning electron microscopy to assess the IA and CP. Micro-Raman spectroscopy was used to determine the DC in different depths. Data were subjected to ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics (p < 0.05). Pearson correlation coefficient was determined to assess the relationship among the parameters of interest. RESULTS Gap/total interface volume ratio ranged between 0.22-0.47%. RBCs applied in bulk revealed significantly lower gap volume (p < 0.001) and CP (p < 0.05). Each group showed complete detachment on the pulpal and partial on the lateral walls, except for group3. While the highest DC% was achieved by the conventional RBC (87.2%), followed by the flowable bulk-fill (81.2%), SFRC provided the best bottom to top DC ratio (bulk: 96.4%, layered: 98.7%). The effect of factors studied (RBC type, filling technique) on IA and DC was significant (p < 0.001). SIGNIFICANCE Bulk placement of RBCs exhibited lower interfacial gap volume and achieved satisfactory DC without significant correlation between these parameters. Incremental insertion of SFRC had no advantage over bulk placement in terms of IA and DC.
Collapse
Affiliation(s)
- Viktória Néma
- Department of Operative and Esthetic Dentistry, Faculty of Dentistry, University of Szeged, Tisza Lajos Blvd 64-66, 6720 Szeged, Hungary
| | - Sándor Kunsági-Máté
- Department of Organic and Pharmacological Chemistry, University of Pécs Medical School, Faculty of Pharmacy, Honvéd street 1, 7624 Pécs, Hungary; János Szentágothai Research Center, University of Pécs, Ifjúság Street 12, 7624 Pécs, Hungary
| | - Zsuzsanna Őri
- Department of Nutritional Sciences and Dietetics, University of Pécs, Faculty of Health Sciences, Vörösmarty Street 4, 7621 Pécs, Hungary; Department of Physical Chemistry and Materials Science, University of Pécs, Faculty of Sciences, Ifjúság Street 6, 7624 Pécs, Hungary
| | - Tamás Kiss
- Department of Pharmacology and Pharmacotherapy, University of Pécs Medical School, Szigeti Street 12, 7624 Pécs, Hungary
| | - Péter Szabó
- János Szentágothai Research Center, University of Pécs, Ifjúság Street 12, 7624 Pécs, Hungary
| | - József Szalma
- Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Tüzér Street 1, 7623 Pécs, Hungary
| | - Márk Fráter
- Department of Operative and Esthetic Dentistry, Faculty of Dentistry, University of Szeged, Tisza Lajos Blvd 64-66, 6720 Szeged, Hungary
| | - Edina Lempel
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Tüzér Street 1, 7623 Pécs, Hungary.
| |
Collapse
|
13
|
Shu F, Chen H, Zhang Z, Dun Z, Lv W, Sun W, Liu M. Shear Bond Strength to Enamel, Mechanical Properties and Cellular Studies of Fiber-Reinforced Composites Modified by Depositing SiO 2 Nanofilms on Quartz Fibers via Atomic Layer Deposition. Int J Nanomedicine 2024; 19:2113-2136. [PMID: 38476282 PMCID: PMC10929249 DOI: 10.2147/ijn.s446584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 02/13/2024] [Indexed: 03/14/2024] Open
Abstract
Introduction Poor interfacial bonding between the fibers and resin matrix in fiber-reinforced composites (FRCs) is a significant drawback of the composites. To enhance the mechanical properties of FRC, fibers were modified by depositing SiO2 nanofilms via the atomic layer deposition (ALD) technique. This study aims to evaluate the effect of ALD treatment of the fibers on the mechanical properties of the FRCs. Methods The quartz fibers were modified by depositing different cycles (50, 100, 200, and 400) of SiO2 nanofilms via the ALD technique and FRCs were proposed from the modified fibers. The morphologies, surface characterizations of nanofilms, mechanical properties, and cytocompatibility of FRCs were systematically investigated. Moreover, the shear bond strength (SBS) of FRCs to human enamel was also evaluated. Results The SEM and SE results showed that the ALD-deposited SiO2 nanofilms have good conformality and homogeneity. According to the results of FTIR and TGA, SiO2 nanofilms and quartz fiber surfaces had good chemical combinations. Three-point bending tests with FRCs showed that the deposited SiO2 nanofilms effectively improved FRCs' strength and Group D underwent 100 deposition cycles and had the highest flexural strength before and after aging. Furthermore, the strength of the FRCs demonstrated a crescendo-decrescendo tendency with SiO2 nanofilm thickness increasing. The SBS results also showed that Group D had outstanding performance. Moreover, the results of cytotoxicity experiments such as cck8, LDH and Elisa, etc., showed that the FRCs have good cytocompatibility. Conclusion Changing the number of ALD reaction cycles affects the mechanical properties of FRCs, which may be related to the stress relaxation and fracture between SiO2 nanofilm layers and the built-up internal stresses in the nanofilms. Eventually, the SiO2 nanofilms could enhance the FRCs' mechanical properties and performance to enamel by improving the interfacial bonding strength, and have good cytocompatibility.
Collapse
Affiliation(s)
- Fei Shu
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Nanjing Medical University, Jiangsu Province Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing, People’s Republic of China
| | - Hong Chen
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Nanjing Medical University, Jiangsu Province Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing, People’s Republic of China
| | - Zhihao Zhang
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Nanjing Medical University, Jiangsu Province Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing, People’s Republic of China
| | - Zhiyue Dun
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Nanjing Medical University, Jiangsu Province Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing, People’s Republic of China
| | - Weijin Lv
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Nanjing Medical University, Jiangsu Province Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing, People’s Republic of China
| | - Wangxinyue Sun
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Nanjing Medical University, Jiangsu Province Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing, People’s Republic of China
| | - Mei Liu
- Department of Prosthodontics, The Affiliated Stomatological Hospital of Nanjing Medical University, Jiangsu Province Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing, People’s Republic of China
| |
Collapse
|
14
|
Alshabib A, Silikas N, Watts DC. Properties of model E-glass fiber composites with varying matrix monomer ratios. Dent Mater 2024; 40:441-450. [PMID: 38129191 DOI: 10.1016/j.dental.2023.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 12/08/2023] [Accepted: 12/08/2023] [Indexed: 12/23/2023]
Abstract
OBJECTIVE To evaluate properties of fiber-reinforced-composites (FRC) containing Bis-EMA/UDMA monomers but identical dispersed phase (60% wt BaSi glass power +10% wt E-glass fibre). METHODS A control (Group A), monomer mixture comprising 60% Bis-GMA, 30% TEGDMA, and 10% PMMA (typical FRC monomers) was used. The following monomer mass fractions were mixed: 50% bis-GMA plus 50% of different ratios of Bis-EMA+UDMA to produce consistent formulations (Groups B-E) of workable viscosities was also studied. Flexural strength (FS), fracture toughness (KIC), water sorption (SP), solubility (SL) and hygroscopic expansion (HE) were measured. FS and KIC specimens were stored for 1, 7 d, and 30 d in water at 37 °C. SP/SL specimens were water-immersed for 168d, weighed at intervals, then dried for 84 d at 37 °C. To analyze differences in FS, and KIC, a two-way ANOVA and Tukey post-hoc tests (α = 0.05) were conducted. For SP/SL, and HE, one-way ANOVA with subsequent Tukey post-hoc tests (α = 0.05) were utilized. RESULTS FS and KIC for groups A, D, E decreased progressively after 1 d. Groups B and C (highest amounts of Bis-EMA) did not decrease significantly. The modified matrix composites performed significantly better than the control group for SP and HE. The control group outperformed the experimental composites only for SL with up to 250% higher SL for group E (6.9 μg/mm) but still below the maximum permissible threshold of 7.5 μg/mm. SIGNIFICANCE EXPERIMENTAL: composites with highest amounts of Bis-EMA showed improved hydrolytic stability and overall enhancement in several clinically-relevant properties. This makes them potential candidates for alternative matrices to a semi-interpenetrating network in fiber-reinforced composites.
Collapse
Affiliation(s)
- Abdulrahman Alshabib
- Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| | - Nikolaos Silikas
- Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK
| | - David C Watts
- Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK.
| |
Collapse
|
15
|
da Silva EM, Amaral CM, Jardim RN, Barbosa MP, Rabello TB. Influence of Specimen Dimension, Water Immersion Protocol, and Surface Roughness on Water Sorption and Solubility of Resin-Based Restorative Materials. MATERIALS (BASEL, SWITZERLAND) 2024; 17:984. [PMID: 38473457 DOI: 10.3390/ma17050984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 02/16/2024] [Accepted: 02/18/2024] [Indexed: 03/14/2024]
Abstract
The evaluation of water sorption and solubility is pivotal for the development of new resin-based restorative materials with the potential for clinical application. The purpose of the present study was to evaluate the influence of the specimen dimension, water immersion protocol, and surface roughness on the water sorption and solubility of three resin-based restorative materials. Disk-shaped specimens of 15 mm × 1 mm, 10 mm × 1 mm, and 6 mm × 1 mm were produced with a composite resin (Z100), a resin cement (RelyX ARC), and an adhesive system (Single Bond 2-SB2). The specimens were immersed in distilled water according to four protocols: ISO (all the specimens for each group were vertically immersed in 50 mL); IV-10 (the specimens were individually and vertically immersed in 10 mL); IH-10 (the specimens were individually and horizontally immersed in 10 mL); and IH-2 (the specimens were individually and horizontally immersed in 2 mL). The surface roughness (Sa and Sp) was evaluated using an atomic force microscope, and the degree of conversion was determined using FT-IR spectrometry. The specimen dimension and water immersion protocol had no effect on water sorption and solubility. For the three resin-based restorative materials, Sp was higher than Sa. The degree of conversion was not influenced by the specimen dimension. The variations in the specimen dimension and water immersion protocol compared to those determined by ISO 4049 did not prevent the comparison between the values of water sorption and solubility obtained for a given resin-based restorative material.
Collapse
Affiliation(s)
- Eduardo Moreira da Silva
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Cristiane Mariote Amaral
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Renata Nunes Jardim
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Marianna Pires Barbosa
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói 24040-110, Brazil
| | - Tiago Braga Rabello
- Faculdade de Odontologia, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-902, Brazil
| |
Collapse
|
16
|
Pinheiro ACP, Aires OV, Gasperini MRC, Lima LCD, Shimokawa CAK, Turbino ML. The effect of tooth bleaching using violet LED (405-410 nm) on the properties of resin-based composites. Photodiagnosis Photodyn Ther 2023; 44:103883. [PMID: 37944626 DOI: 10.1016/j.pdpdt.2023.103883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 10/30/2023] [Accepted: 11/03/2023] [Indexed: 11/12/2023]
Abstract
BACKGROUND The objective of this study was to evaluate the effect of bleaching techniques, including or not the use of violet light (405-410 nm), on resin-based composites' color, surface roughness, nanohardness, and elastic modulus. METHODS Ninety-six disk-shaped specimens (12 mm x 2 mm; n = 12) were prepared using Filtek Z350 XT (Z350) and IPS Empress Direct (ED) resin-based composites. After 24 h, specimens were stained in red wine for 28 days. After staining, specimens were divided into four experimental groups: 40 % Hydrogen Peroxide (HP); Violet Light (VL); 40 % Hydrogen Peroxide associated with Violet Light (HP+VL), and a control group - no treatment (NT). Specimens were evaluated at six experimental times: initial (24 h after light curing); after staining and after the 1st, 2nd, 3rd, and 4th bleaching sessions regarding the color change (ΔE00, L*, a*, b*, and WID); roughness (Ra), nanohardness and elastic modulus (GPa). Two-way analysis of variance for repeated measures was performed (α=0.05 %). RESULTS There was a statistically significant difference between staining and the 1st bleaching session for all ED groups (p<0.05). After the last bleaching session, there were no differences between the experimental and the control groups of both resin-based composites. Bleaching using violet light did not change the roughness, nanohardness and elastic modulus of the tested resin-based composites (p>0.05). CONCLUSIONS Although hydrogen peroxide and violet light remove pigments from resin-based composites without affecting their surface roughness, nanohardness, and elastic modulus, the color change was similar to the one obtained by immersion in distilled water.
Collapse
Affiliation(s)
- Amanda Cavalcante Pereira Pinheiro
- Department of Restorative Dentistry, University of São Paulo, School of Dentistry, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil
| | - Olívia Vieira Aires
- Department of Restorative Dentistry, University of São Paulo, School of Dentistry, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil
| | - Mariana Rossi Carneiro Gasperini
- Department of Restorative Dentistry, University of São Paulo, School of Dentistry, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil
| | - Leonardo Custódio de Lima
- Department of Restorative Dentistry, University of São Paulo, School of Dentistry, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil
| | - Carlos Alberto Kenji Shimokawa
- Department of Restorative Dentistry, University of São Paulo, School of Dentistry, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil.
| | - Míriam Lacalle Turbino
- Department of Restorative Dentistry, University of São Paulo, School of Dentistry, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil
| |
Collapse
|
17
|
Thanyasiri S, Naruphontjirakul P, Padunglappisit C, Mirchandani B, Young AM, Panpisut P. Assessment of physical/mechanical properties and cytotoxicity of dual-cured resin cements containing Sr-bioactive glass nanoparticles and calcium phosphate. Dent Mater J 2023; 42:806-817. [PMID: 37880134 DOI: 10.4012/dmj.2023-127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2023]
Abstract
The aim was to develop dual-cured resin cements containing Sr-bioactive glass nanoparticles (Sr-BGNPs; 5 or 10 wt%) and monocalcium phosphate monohydrate (MCPM; 3 or 6 wt%). Effects of additives on degree of monomer conversion (DC), biaxial flexural strength/modulus, shear bond strength (SBS), mass/volume change, color stability, ion release, and cytotoxicity were examined. Controls included material without reactive fillers and Panavia SA Plus (PV). Experimental cements showed higher DC than PV regardless of light activation (p<0.05). Mean SBS and color stability were comparable between experimental cements and PV. Cell viability upon the exposure to sample extracts of experimental cements was 80%-92%. High additive concentrations led to lower strength and modulus than PV (p<0.05). The additives increased mass change, reduced color stability, and promoted ion release. The experimental resin cements demonstrated acceptable mechanical/chemical properties and cytotoxicity. The additives reduced the strength but provided ion release, a desirable action to prevent recurrent caries.
Collapse
Affiliation(s)
| | - Parichart Naruphontjirakul
- Biological Engineering Program, Faculty of Engineering, King Mongkut's University of Technology Thonburi
| | | | - Bharat Mirchandani
- Faculty of Dentistry, Datta Meghe Institute of Higher Education & Research
| | - Anne M Young
- Division of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, Royal Free Hospital
| | - Piyaphong Panpisut
- Faculty of Dentistry, Thammasat University
- Thammasat University Research Unit in Dental and Bone Substitute Biomaterials, Thammasat University
| |
Collapse
|
18
|
Derigi LP, Barros LS, Sugii MM, Turssi CP, França F, Basting RT, Vieira WF. Effect of Commercial Mouth Rinses on Physical Properties of Conventional and Bulk-fill Resin Composites. Oper Dent 2023; 48:720-731. [PMID: 37881067 DOI: 10.2341/23-041-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/10/2023] [Indexed: 10/27/2023]
Abstract
OBJECTIVE To evaluate the effects of commercial mouth rinses on color, roughness, sorption (SR), and solubility (SL) of resin composites. METHODS AND MATERIALS Disc-shaped specimens (stage I: 6 mm × 2 mm; stage II: 10 mm × 1.5 mm) were made from the following resin composites (n=10): conventional nanofilled (Filtek Z350XT, 3M Oral Care), conventional nanohybrid (Luna, SDI), bulk-fill nanofilled (Filtek One Bulk-Fill, 3M Oral Care), and bulk-fill nanohybrid (Aura Bulk-Fill, SDI) exposed to distilled water (control), blue mouth rinse without alcohol (Colgate Total 12 Clean Mint, Colgate-Palmolive), or blue mouth rinse with alcohol and essential oil (Listerine Tartar Control, Johnson & Johnson). In stage I, tests were performed at the baseline, and after the immersion in solution time points to evaluate coordinates of the CIEL*a*b* system (ΔL*, Δa*, Δb*), general color change (ΔEab, ΔE00, and ΔSGU), and surface roughness (Ra). In stage II, SR and SL were evaluated (ISO 4049:2019) after immersion in the solutions for 7 days. The results were evaluated by generalized linear models (Ra, SR), Kruskal-Wallis, and Dunn tests (color, SL), with α = 0.05. RESULTS There were no significative differences for Ra between the solutions. Both mouth rinses promoted significantly negative ΔL* (Luna), Δa* (Filtek One Bulk-fill), and Δb* (all materials except conventional nanofilled resin composite). Mouth rinse without alcohol promoted significantly negative Δa* on all resin composites tested. Both mouth rinses promoted higher ΔEab and ΔE00 for bulk-fill resin composites compared to control. Mouth rinse with alcohol caused higher ΔSGU for bulk-fill nanofilled resin composite. It also promoted greater SR in all the resin composites compared with mouth rinse without alcohol and higher SR in nanohybrid resin composites compared with control. Both mouth rinses promoted higher SL values in Luna and differed significantly from control. CONCLUSIONS The physical properties were manufacturer dependent and mediated by mouth rinses. The mouth rinses promoted color changes in the resin composites, pointing out that bulk-fill resin composites were more affected by these effects, especially when the mouth rinse contained essential oil and alcohol.
Collapse
Affiliation(s)
- L P Derigi
- Leonardo Pinheiro Derigi, MSc student, Faculdade São Leopoldo Mandic, Campinas, SP, Brazil
| | - L S Barros
- Leonardo Santos Barros, MSc student, Faculdade São Leopoldo Mandic, Campinas, SP, Brazil
| | - M M Sugii
- Mari Miura Sugii, DDS, MSc, PhD, professor, Groningen University Medical Center, University of Groningen, Groningen, Netherlands
| | - C P Turssi
- Cecilia Pedroso Turssi, DDS, MSc, PhD, professor, Faculdade São Leopoldo Mandic, Campinas, SP, Brazil
| | - Fmg França
- Fabiana Mantovani Gomes França, DDS, MSc, PhD, professor, Faculdade São Leopoldo Mandic, Campinas, SP, Brazil
| | - R T Basting
- Roberta Tarkany Basting, DDS, MSc, PhD, professor, Faculdade São Leopoldo Mandic, Campinas, SP, Brazil
| | - W F Vieira
- *Waldemir Francisco Vieira-Junior, DDS, MSc, PhD, professor, Faculdade São Leopoldo Mandic, Campinas, SP, Brazil
| |
Collapse
|
19
|
Lukomska-Szymanska M, Radwanski M, Kharouf N, Mancino D, Tassery H, Caporossi C, Inchingolo F, de Almeida Neves A, Chou YF, Sauro S. Evaluation of Physical-Chemical Properties of Contemporary CAD/CAM Materials with Chromatic Transition "Multicolor". MATERIALS (BASEL, SWITZERLAND) 2023; 16:4189. [PMID: 37297323 PMCID: PMC10254467 DOI: 10.3390/ma16114189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 05/31/2023] [Accepted: 06/03/2023] [Indexed: 06/12/2023]
Abstract
The use of materials for computer-aided design/computer-aided manufacturing (CAD/CAM) has been rapidly increasing in daily practice. However, one of the main issues regarding modern CAD/CAM materials is their aging in the oral environment, which may lead to significant changes in their overall properties. The aim of this study was to compare the flexural strength, water sorption, cross-link density (softening ratio%), surface roughness, and SEM analysis of three modern CAD/CAM "multicolor" composites. Grandio (Grandio disc multicolor-VOCO GmbH, Cuxhaven, Germany), Shofu (Shofu Block HC-Shofu Inc., Kyoto, Japan), and Vita (Vita Enamic multiColor-Vita Zahnfabrik, Bad Sackingen, Germany) were tested in this study. They were prepared in stick-shaped specimens and submitted to different tests after several aging protocols, such as thermocycling and mechanical cycle loading challenge. Further disc-shaped specimens were also created and tested for water sorption, cross-link density, surface roughness, and SEM ultramorphology, before and after storage in an ethanol-based solution. For flexural strength and ultimate tensile strength, Grandio showed the greatest values both at baseline and after aging (p < 0.05). Grandio and Vita Enamic presented the highest modulus of elasticity and the lowest water sorption (p < 0.05). A significant reduction (p < 0.05) in microhardness after ethanol storage (softening ratio%) was observed especially in Shofu. Grandio had the lowest roughness parameters compared to the other tested CAD/CAM materials, while ethanol storage significantly increased the Ra and RSm values in Shofu (p < 0.05). Despite the comparable modulus of elasticity of Vita and Grandio, this latter showed greater flexural strength and ultimate tensile strength both at baseline and after aging. Hence, Grandio and Vita Enamic may be employed for the anterior teeth and for those restorations requiring load-bearing capacity. Conversely, aging seems to affect several properties of Shofu, so its use for permanent restorations should be well-pondered based on the clinical situation.
Collapse
Affiliation(s)
| | - Mateusz Radwanski
- Department of Endodontics, Medical University of Lodz, 251 Pomorska Str., 92-213 Lodz, Poland;
| | - Naji Kharouf
- Department of Endodontics and Conservative Dentistry, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France; (N.K.)
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Strasbourg University, 67000 Strasbourg, France
| | - Davide Mancino
- Department of Endodontics and Conservative Dentistry, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France; (N.K.)
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Strasbourg University, 67000 Strasbourg, France
| | - Herve Tassery
- Ecole de Médecine Dentaire de Marseille, Université d’Aix-Marseille, 13385 Marseille, France
- Laboratoire Bioinginierie et Nanoscience, LBN, Université de Montpellier, 545 Pr JL Viala, 34090 Montpellier, France
| | | | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70124 Bari, Italy
| | - Aline de Almeida Neves
- Department of Pediatric Dentistry and Orthodontics, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-853, Brazil
| | - Yu Fu Chou
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Ciencias de la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo s/n, Alfara del Patriarca, 46115 Valencia, Spain
| | - Salvatore Sauro
- Independent Researcher, Roma, 65B, 00030 Labico, Italy
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Ciencias de la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo s/n, Alfara del Patriarca, 46115 Valencia, Spain
| |
Collapse
|
20
|
Popescu AD, Tuculina MJ, Diaconu OA, Gheorghiță LM, Nicolicescu C, Cumpătă CN, Petcu C, Abdul-Razzak J, Rîcă AM, Voinea-Georgescu R. Effects of Dental Bleaching Agents on the Surface Roughness of Dental Restoration Materials. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1067. [PMID: 37374271 DOI: 10.3390/medicina59061067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 05/27/2023] [Accepted: 05/30/2023] [Indexed: 06/29/2023]
Abstract
Background and Objectives: This study aimed to evaluate the surface roughness evolution of several finished and polished composites when bleaching materials are applied. The research was conducted on four microhybrid or nanofilled composites that are used in dental restorations. Materials and Methods: For each composite type, 5 samples were selected for control, 5 samples were subjected to the bleaching protocol "office bleach" with 40% hydrogen peroxide, and 5 other samples were subjected to the "home bleach" protocol with 16% carbamide peroxide, resulting in a total number of 60 samples. The surfaces of all the samples were tested for roughness, and the values of the most relevant parameter (Ra), were collected. Comparisons between composites and samples were performed using one-way ANOVA (in Statistical Package for Social Sciences). Results: After the bleaching protocol with 40% hydrogen peroxide gel, it was found that the roughness of the group increased considerably compared to the control group, so the highest roughness was found at GC Gradia direct anterior group, and the lowest value was registered for the 3M ESPE Valux Plus group. Following the bleaching protocol with 16% carbamide peroxide (home bleach), it was noted that the sample surfaces were not as affected. In this case, the lowest roughness was found at 3M ESPE Valux Plus group, and the highest roughness was registered for the GC G-aenial anterior group. Following the interpretation of the results, all four types of dental composites tested showed significant surface roughness differences between the groups subjected to bleaching protocols and those kept as control (p < 0.05). Conclusions: The surfaces of the samples were affected by the bleaching protocols by increasing the roughness compared to the control samples.
Collapse
Affiliation(s)
- Alexandru Dan Popescu
- Department of Endodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
| | - Mihaela Jana Tuculina
- Department of Endodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
| | - Oana Andreea Diaconu
- Department of Endodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
| | - Lelia Mihaela Gheorghiță
- Department of Endodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
| | - Claudiu Nicolicescu
- Department of Engineering and Management of the Technological Systems, Faculty of Mechanics, University of Craiova, 1 Calugareni, 220037 Drobeta-Turnu Severin, Romania
| | - Cristian Niky Cumpătă
- Faculty of Dental Medicine, University Titu Maiorescu of Bucharest, 031593 Bucharest, Romania
| | - Cristiana Petcu
- Department of Prosthodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
| | - Jaqueline Abdul-Razzak
- Department of Infant Care-Pediatrics-Neonatology & Doctoral School, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
| | - Ana Maria Rîcă
- Department of Endodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
| | | |
Collapse
|
21
|
Muradbegovic A, Par M, Panduric V, Zugec P, Tauböck TT, Attin T, Tarle Z, Marovic D. Water-Induced Changes in Experimental Resin Composites Functionalized with Conventional (45S5) and Customized Bioactive Glass. J Funct Biomater 2023; 14:298. [PMID: 37367262 DOI: 10.3390/jfb14060298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 05/19/2023] [Accepted: 05/25/2023] [Indexed: 06/28/2023] Open
Abstract
The aim of the study was to evaluate microhardness, mass changes during 1-year water immersion, water sorption/solubility, and calcium phosphate precipitation of experimental composites functionalized with 5-40 wt% of two types of bioactive glass (BG): 45S5 or a customized low-sodium fluoride-containing formulation. Vickers microhardness was evaluated after simulated aging (water storage and thermocycling), water sorption and solubility were tested according to ISO 4049, and calcium phosphate precipitation was studied by scanning electron microscopy, energy dispersive X-ray spectroscopy, and Fourier-transform infrared spectroscopy. For the composites containing BG 45S5, a significant reduction in microhardness was observed with increasing BG amount. In contrast, 5 wt% of the customized BG resulted in statistically similar microhardness to the control material, while higher BG amounts (20 and 40 wt%) resulted in a significant improvement in microhardness. Water sorption was more pronounced for composites containing BG 45S5, increasing 7-fold compared to the control material, while the corresponding increase for the customized BG was only 2-fold. Solubility increased with higher amounts of BG, with an abrupt increase at 20 and 40 wt% of BG 45S5. Calcium phosphate was precipitated by all composites with BG amounts of 10 wt% or more. The improved properties of the composites functionalized with the customized BG indicate better mechanical, chemical, and dimensional stability without compromising the potential for calcium phosphate precipitation.
Collapse
Affiliation(s)
- Alen Muradbegovic
- Muradbegović Dental Clinic, Malkočeva 3, 75000 Tuzla, Bosnia and Herzegovina
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Vlatko Panduric
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Paula Zugec
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Tobias T Tauböck
- Department of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland
| | - Thomas Attin
- Department of Conservative and Preventive Dentistry, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland
| | - Zrinka Tarle
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Danijela Marovic
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| |
Collapse
|
22
|
Gauthier R, Abouelleil H, Boussès Y, Brulat-Bouchard N, Colon P, Chenal JM, Tillier Y, Grosgogeat B. Experimental Investigation of Dental Composites Degradation After Early Water Exposure. J Biomech Eng 2023; 145:1150160. [PMID: 36350265 DOI: 10.1115/1.4056197] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 11/01/2022] [Indexed: 11/10/2022]
Abstract
While dental composite long-term aging has already been studied in the past, no data exist about the early aging while it might be detrimental regarding the composites' longevity. This study aims to better understand the effects of early water exposure on dental composites. Dental resin composites with different fillers ratio were subjected to water exposure during 24 h, 1 week, or 1 month. After photopolymerization, the samples were stored at different conditions, whether in wet or dry condition (W, D, respectively) and in wet conditions after a first 24 h storage in dry conditions (DW). Three-point bending tests were performed to measure the flexural modulus. The samples were then subjected to a sorption/desorption protocol. While the matrix alone did not undergo any mechanical degradation with exposure time, the composites matrices presented a decrease in elastic modulus. This decrease was the highest for the matrix with nonsilanized fillers. Interestingly, the DW condition was detrimental for all the samples. Regarding the sample with nonsilanized fillers in DW for 1 month presented an elastic modulus lower than the matrix alone. These results were assigned to the sorption capacity of the polymer matrix, suggesting that the diffusion mechanisms and the nature of water molecules are determinant in the composite degradation. This study showed that dental composite early degradation mechanisms after water exposure are involved in the polymer matrix postpolymerization process as soon as after 24 h. Such mechanisms are detrimental in terms of the dental composite efficiency and have to be understood.
Collapse
Affiliation(s)
- Rémy Gauthier
- MATEIS, CNRS, INSA de Lyon, Université Claude Bernard Lyon 1, Univ Lyon, UMR5510, Villeurbanne F-69621, France
| | - Hazem Abouelleil
- Laboratoire des Multimatériaux et Interfaces, UMR CNRS 5615, Université Claude Bernard Lyon 1, Univ Lyon, Villeurbanne F-69622, France; Faculté d'Odontologie, Université Claude Bernard Lyon 1, Univ Lyon, Lyon 69008, France
| | - Yoan Boussès
- CEMEF Centre de Mise En Forme des Matériaux, UMR CNRS 7635, MINES ParisTech, PSL Research University, Sophia Antipolis 06904, France
| | - Nathalie Brulat-Bouchard
- CEMEF Centre de Mise En Forme des Matériaux, UMR CNRS 7635, MINES ParisTech, PSL Research University, Sophia Antipolis 06904, France; UFR d'Odontologie Nice Côte d'Azur, Université Nice Sophia Antipolis, Nice 06300, France
| | - Pierre Colon
- Laboratoire des Multimatériaux et Interfaces, UMR CNRS 5615, Université Claude Bernard Lyon 1, Univ Lyon, Villeurbanne F-69622, France; Assistance Publique-Hôpitaux de Paris, Hôpital Rothschild, Service D'odontologie, Faculté Dentaire, Université de Paris, Paris 75012, France
| | - Jean-Marc Chenal
- MATEIS, CNRS, INSA de Lyon, Université Claude Bernard Lyon 1, Univ Lyon, UMR5510, Villeurbanne F-69621, France
| | - Yannick Tillier
- CEMEF Centre de Mise En Forme des Matériaux, UMR CNRS 7635, MINES ParisTech, PSL Research University, Sophia Antipolis 06904, France
| | - Brigitte Grosgogeat
- Laboratoire des Multimatériaux et Interfaces, UMR CNRS 5615, Université Claude Bernard Lyon 1, Univ Lyon, Villeurbanne F-69622, France; Faculté d'Odontologie, Université Claude Bernard Lyon 1, Univ Lyon, Lyon 69008, France; Hospices Civils de Lyon, Service d'Odontologie, Lyon 69007, France
| |
Collapse
|
23
|
Islam MS, Nassar M, Elsayed MA, Jameel DB, Ahmad TT, Rahman MM. In Vitro Optical and Physical Stability of Resin Composite Materials with Different Filler Characteristics. Polymers (Basel) 2023; 15:polym15092121. [PMID: 37177267 PMCID: PMC10180670 DOI: 10.3390/polym15092121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 04/22/2023] [Accepted: 04/26/2023] [Indexed: 05/15/2023] Open
Abstract
The objective of this study was to compare the physical and optical stability of resin composite materials with different filler characteristics. Ninety-six resin composite blocks (6 mm × 6 mm × 2 mm) were prepared using four different types of resin composite, divided into four groups. Specimens from the same material were randomly divided into four groups (n = 6) and allocated for Vickers hardness (VH), water sorption, solubility (WS/SL), and staining and aging challenges tests. One-way ANOVA showed significant differences in microhardness (p = 0.0001), WS (p = 0.0001), and SL (p = 0.003) among the tested groups. Beautifil II LS recorded the highest hardness, and CharmFil®Flow had the lowest value. Beautifil Injectable X and II LS showed negative WS, whereas the other groups had positive values. All groups showed positive SL. Repeated measures ANOVA showed significant color parameter alteration in the tested groups (p = 0.0001). All groups showed significant color shifting after one week of the staining challenge. Repeated measures ANOVA showed a significant color parameter (p = 0.0001) and weight (p = 0.001) alteration after the aging challenge. The optical and physical stability of resin composites may vary according to filler characteristics. Clinicians should choose the composite as per the desired outcome.
Collapse
Affiliation(s)
- Md Sofiqul Islam
- RAK College of Dental Sciences, RAK Medical and Health Sciences University, Ras Al-Khaimah P.O. Box 12973, United Arab Emirates
| | - Mohannad Nassar
- Department of Preventive and Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah P.O. Box 27272, United Arab Emirates
| | - Mohamed Ahmed Elsayed
- RAK College of Dental Sciences, RAK Medical and Health Sciences University, Ras Al-Khaimah P.O. Box 12973, United Arab Emirates
- Department of Endodontics, Faculty of Dentistry, Assiut University, Assiut 71515, Egypt
| | - Dania Burhan Jameel
- RAK College of Dental Sciences, RAK Medical and Health Sciences University, Ras Al-Khaimah P.O. Box 12973, United Arab Emirates
| | - Thana Tariq Ahmad
- RAK College of Dental Sciences, RAK Medical and Health Sciences University, Ras Al-Khaimah P.O. Box 12973, United Arab Emirates
| | - Muhammed Mustahsen Rahman
- RAK College of Dental Sciences, RAK Medical and Health Sciences University, Ras Al-Khaimah P.O. Box 12973, United Arab Emirates
| |
Collapse
|
24
|
Tian J, Wu Z, Wang Y, Han C, Zhou Z, Guo D, Lin Y, Ye Z, Fu J. Multifunctional dental resin composite with antibacterial and remineralization properties containing nMgO-BAG. J Mech Behav Biomed Mater 2023; 141:105783. [PMID: 36996527 DOI: 10.1016/j.jmbbm.2023.105783] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 03/10/2023] [Accepted: 03/13/2023] [Indexed: 03/15/2023]
Abstract
The inherent characteristics of resin composite can lead to micro-leakage after polymerization shrinkage. The bacteria invasion through edge micro-leakage and attachment onto the material surface can cause secondary caries, reducing the service life of resin composites. In this study, magnesium oxide nanoparticles (nMgO) as an inorganic antimicrobial agent and bioactive glass (BAG) as a remineralization agent were simultaneously incorporated into the resin composite. With the addition of both nMgO and BAG, the resin composite showed an excellent antimicrobial effect compared to the resin composite with nMgO or BAG only. The remineralization capacity of demineralized dentin increased with the increasing content of BAG. Vickers hardness, compressive strength, and flexural strength of the resin composite with nMgO-BAG were not significantly affected compared to the ones with the same total filler amount but with BAG only. The depth of cure and water sorption values of the resin composite showed an increasing trend with the increasing total amount of nMgO and BAG fillers. This developed multifunctional resin composite is expected to reduce bacterial invasion and promote remineralization of early caries damage.
Collapse
Affiliation(s)
- Jing Tian
- Department of Prosthodontics, The Affiliated Hospital of Qingdao University, Qingdao, China; School of Stomatology, Qingdao University, Qingdao, China
| | - Zhongyuan Wu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yuan Wang
- Department of Prosthodontics, The Affiliated Hospital of Qingdao University, Qingdao, China; School of Stomatology, Qingdao University, Qingdao, China
| | - Chunhua Han
- Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Zixuan Zhou
- Department of Prosthodontics, The Affiliated Hospital of Qingdao University, Qingdao, China; School of Stomatology, Qingdao University, Qingdao, China
| | - Di Guo
- Department of Prosthodontics, The Affiliated Hospital of Qingdao University, Qingdao, China; School of Stomatology, Qingdao University, Qingdao, China
| | - Yifan Lin
- Division of Paediatric Dentistry and Orthodontics, Faculty of Dentistry, The University of Hong Kong, China
| | - Zhou Ye
- Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, China.
| | - Jing Fu
- Department of Prosthodontics, The Affiliated Hospital of Qingdao University, Qingdao, China; School of Stomatology, Qingdao University, Qingdao, China.
| |
Collapse
|
25
|
Kudo H, Wakabayashi K, Sasaki JI, Tamiya S, Ishigaki S. Fracture strength and behavior of resin-faced CAD/CAM anterior crowns. Dent Mater J 2023; 42:86-91. [PMID: 36288943 DOI: 10.4012/dmj.2022-127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The fracture strength and behavior of a novel resin-faced computer-aided design/computer-aided manufacturing (CAD/CAM) crown were investigated to evaluate application to the anterior teeth. Resin-faced CAD/CAM crowns were fabricated by arranging a resin composite on a frame prepared from a CAD/CAM resin block. The fracture strength was evaluated after 24 h of complete polymerization (day 0) and after water immersion for 30 days (day 30). Uniaxial loading was applied to the center point between the incisal edge and cingulum (loading point 1) or at 1.5 mm from the incisal edge (loading point 2). There was no significant difference in the fracture strength of the resin-faced CAD/CAM crowns between day 0 and 30 at loading point 1. At loading point 2, they exhibited decreased fracture strength after water immersion; however, the mean strength was still >1 kN. This novel crown showed good mechanical properties to serve as a prosthesis for the anterior teeth.
Collapse
Affiliation(s)
- Hiroki Kudo
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| | | | - Jun-Ichi Sasaki
- Department of Biomaterials Science, Osaka University Graduate School of Dentistry
| | - Shingo Tamiya
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| | - Shoichi Ishigaki
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry
| |
Collapse
|
26
|
Color Stability of Resin Cements after Water Aging. Polymers (Basel) 2023; 15:polym15030655. [PMID: 36771956 PMCID: PMC9919001 DOI: 10.3390/polym15030655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2022] [Revised: 01/23/2023] [Accepted: 01/24/2023] [Indexed: 01/31/2023] Open
Abstract
The color stability of resin cements plays a key role in the achievement of esthetically-pleasant restorations. Resin luting materials can be mainly divided into two main classes: adhesive (relying on previous application of adhesive systems) or self-adhesive (also known as one-step cements). The different chemical compositions determine their physio-mechanical characteristics which, in turns, influence their color stability. To evaluate the color variations of different dual-cured resin cements after water aging, 80 disc-shaped specimens (15 mm in diameter and 1.2 mm thick) were obtained from the following resin cements (n = 10): (1) Maxcem Elite Universal, MCU (Kerr); (2) RelyX Universal, RXU (3M); (3) Calibra Ceram, CAL (Dentsply); (4) Multilink, MUL (Ivoclar-Vivadent); (5) Panavia V5, PAN (Kuraray); (6) Calibra Universal, CUN (Dentsply); (7) SpeedCEM Plus, SCP (Ivoclar); and (8) Panavia SA, PSA (Kuraray). After light-polymerization, the specimens were measured with a spectrophotometer and CIELab* values were recorded. The specimens were then placed in a digitally controlled thermostatic water bath at 60° for 30 days and afterwards the color measurements were repeated. Color differences were calculated for each specimen before and after water-aging procedures with ΔEab formula and the data were statistically analyzed (p < 0.05). The type of cement statistically influenced the ΔEab (p < 0.05), with MCU showing the lowest color variations (4.3 ± 0.7) whereas RXU and PSA the highest (16.9 ± 1.6 and 16.8 ± 1.2, respectively). No differences were observed between CAL, CUN and SCP (p = 0.05). Color stability is related to the chemical composition of the resinous luting materials, thus material dependent.
Collapse
|
27
|
Saha S, Roy S. Metallic Dental Implants Wear Mechanisms, Materials, and Manufacturing Processes: A Literature Review. MATERIALS (BASEL, SWITZERLAND) 2022; 16:ma16010161. [PMID: 36614500 PMCID: PMC9821388 DOI: 10.3390/ma16010161] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Revised: 11/29/2022] [Accepted: 12/13/2022] [Indexed: 06/12/2023]
Abstract
OBJECTIVES From the treatment of damaged teeth to replacing missing teeth, dental biomaterials cover the scientific interest of many fields. Dental biomaterials are one of the implants whose effective life depends vastly on their material and manufacturing techniques. The purpose of this review is to summarize the important aspects for metallic dental implants from biomedical, mechanical and materials science perspectives. The review article will focus on five major aspects as mentioned below. Tooth anatomy: Maximizing the implant performance depends on proper understanding of human tooth anatomy and the failure behavior of the implants. Major parts from tooth anatomy including saliva characteristics are explored in this section. Wear mechanisms: The prominent wear mechanisms having a high impact on dental wear are abrasive, adhesive, fatigue and corrosion wear. To imitate the physiological working condition of dental implants, reports on the broad range of mastication force and various composition of artificial saliva have been included in this section, which can affect the tribo-corrosion behavior of dental implants. Dental implants classifications: The review paper includes a dedicated discussion on major dental implants types and their details for better understanding their applicability and characteristics. Implant materials: As of today, the most established dental implant materials are SS316L, cobalt chrome alloy and titanium. Detailed discussion on their material properties, microstructures, phase transformations and chemical compositions have been discussed here. Manufacturing techniques: In terms of different production methods, the lost wax casting method as traditional manufacturing is considered. Selective Laser Melting (SLM) and Directed Energy Deposition (DED) as additive manufacturing techniques (AM) have been discussed. For AM, the relationships between process-property-performance details have been explored briefly. The effectiveness of different manufacturing techniques was compared based on porosity distribution, mechanical and biomechanical properties. SUMMARY Despite having substantial research available on dental implants, there is a lack of systematic reviews to present a holistic viewpoint combining state-of-the-art from biomedical, mechanical, materials science and manufacturing perspectives. This review article attempts to combine a wide variety of analyzing approaches from those interdisciplinary fields to deliver deeper insights to researchers both in academia and industry to develop next-generation dental implants.
Collapse
|
28
|
Yıldız P, Güneş Ünlü D, Talay Çevlik E, Üşümez A. Removal of lithium disilicate veneers with Er,Cr:YSGGL laser: now? Or after ageing? Lasers Med Sci 2022; 38:12. [PMID: 36539658 DOI: 10.1007/s10103-022-03689-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Accepted: 11/08/2022] [Indexed: 12/24/2022]
Abstract
This study was purposed to assess the impact of ageing and resin cements polymerized with different modes on the removal time of lithium disilicate (LiSi) ceramics using Er,Cr:YSGG laser. Ninety LiSi slabs (6 × 6 × 1 mm) were cemented to freshly extracted bovine teeth using cements polymerized with different modes (light-curing (LC), dual-curing (DC), self-curing (SC)). The specimens were divided into subgroups according to ageing conditions (no thermal cycling, 5000 or 30,000 thermal cycling). After that, Er,Cr:YSGG laser was applied until LiSi slabs were debonded; the removal time was recorded. Vickers microhardness test, SEM and EDS analyses were performed for specimens with the longest exposure time to laser application in the groups. One uncemented sample was also used as a control. Data were analyzed with two-way ANOVA and Tukey post hoc test. Ageing and cement polymerization mode significantly affected the removal time of LiSi specimens. The removal time for the self-curing resin cement group (22.67 ± 12.68 s) was significantly longer than for cements polymerized with other methods (LC = 10.833 ± 7.28 s, DC = 12.0 ± 7.96 s). Removal time was significantly reduced after ageing in all polymerization modes; however, there were no significant differences between 5000 (11.83 ± 7.52 s) and 30,000 (11.83 ± 7.26 s) thermal cycling groups. Self-curing resin cements had prolonged the laser-aided removal time for LiSi ceramics. It can be concluded that Er,Cr:YSGG laser-aided removal of LiSi veneers after clinical use can be done more faster than its immediate removal.
Collapse
Affiliation(s)
- Pınar Yıldız
- Department of Prosthodontics, Faculty of Dentistry, Nuh Naci Yazgan University, Kayseri, 38040, Turkey.
| | - Damla Güneş Ünlü
- Department of Prosthodontics, Faculty of Dentistry, Nuh Naci Yazgan University, Kayseri, 38040, Turkey
| | - Esra Talay Çevlik
- Department of Prosthodontics, Faculty of Dentistry, Adnan Menderes University, Aydın, Turkey
| | - Aslıhan Üşümez
- Division of Prosthodontics, Dentalplus Implant Clinics, Istanbul, Turkey
| |
Collapse
|
29
|
HATIRLI H, TONGA G, BOYRAZ Ş. WATER SORPTION, SOLUBILITY AND COLOR STABILITY OF DIFFERENT BULK-FILL RESTORATIVE MATERIALS. CUMHURIYET DENTAL JOURNAL 2022. [DOI: 10.7126/cumudj.1116211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Objectives: The aim of this study was to evaluate the color stability, water sorption and solubility of recent bulk-fill restorative materials.
Materials and Methods: Seventy disc shaped specimens (height:1mm, diameter:15mm) were prepared with a micro-hybrid composite resin (Z250; Filtek Z250, 3M ESPE), two resin-based bulk-fill (Filtek One Bulk Fill, 3M ESPE and EBF; Estelite Bulk-Fill Flow, Tokuyama Dental), glass ionomer-based restorative (Equia FF; Equia Forte Fil, GC Dental), self-cure and light-cure alkasite (CN; Cention N, Ivoclar Vivadent) and indirect composite resin (Gradia P; Gradia Plus, GC Dental) (n=10). Baseline color measurements were performed and mass of the samples (m1) were noted. Color measurements were repeated after 24 h and 28 days immersion of the specimens in water. After the 28-days immersion, mass was noted as m2. Specimens were kept in desiccators and final mass (m3) were recorded. The color change (ΔE00) water absorption (WSP) and water solubility (WSL) of the specimens were calculated.
Results: After 28-days immersion, Gradia P showed significantly lower water sorption than EBF and Equia FF groups (p0.05). The lowest solubility was observed in Z250and Gradia P. The lowest (ΔE00) was observed in self-cured CN group (p
Collapse
Affiliation(s)
- Hüseyin HATIRLI
- TOGU Diş Hekimliği Fakültesi Restoratif Diş Tedavisi Anabilidalı
| | - Gülşah TONGA
- TOGU Diş Hekimliği Fakültesi Restoratif Diş Tedavisi Anabilidalı
| | - Şura BOYRAZ
- Yozgat Bozok Üniversitesi Diş Hekimliği Fakültesi Restoratif Diş Tedavisi Anabilimdalı
| |
Collapse
|
30
|
Zhang X, Ma X, Liao M, Liu F, Wei Q, Shi Z, Mai S, He J. Properties of Bis-GMA free bulk-filled resin composite based on high refractive index monomer Bis-EFMA. J Mech Behav Biomed Mater 2022; 134:105372. [DOI: 10.1016/j.jmbbm.2022.105372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 07/10/2022] [Accepted: 07/14/2022] [Indexed: 12/01/2022]
|
31
|
Huang W, Ren L, Cheng Y, Xu M, Luo W, Zhan D, Sano H, Fu J. Evaluation of the Color Stability, Water Sorption, and Solubility of Current Resin Composites. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15196710. [PMID: 36234048 PMCID: PMC9572228 DOI: 10.3390/ma15196710] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 09/12/2022] [Accepted: 09/19/2022] [Indexed: 05/13/2023]
Abstract
This study aims to assess the color stability, water sorption, and solubility of 11 resin composites as commercially available dental products. Twenty samples (10 mm in diameter and 2 mm in thickness) of each material were fabricated using a customized silicone mold, followed by immersion in each of curry, coffee, wine, and distilled water for 28 days (n = 5). Baseline shade and color changes (ΔE) were measured using a reflection spectrophotometer. The CIE L*, a*, b* system was used to evaluate the color changes. Five samples of each resin composite were applied to test water sorption and solubility according to ISO 4049:2009. As a result, the ∆E values were significantly influenced by each of the three factors (composition of material, solution, time) and the interactions between them (p < 0.001). Highest resistance to discoloration was achieved by Ceram.X One Universal (CXU), followed by Magnafill Putty (MP). Generally, microhybrid composites showed fewer color changes than nanohybrid composites and giomers. DX. Universal and Filtek Z350 XT showed the highest ΔE values in all colorants. All materials tested in this study fulfilled the criteria of ISO 4049:2009; CXU and MP had the lowest water sorption and solubility. The Pearson test showed statistically significant positive correlations between water sorption and ΔE and between solubility and ΔE.
Collapse
Affiliation(s)
- Wenkai Huang
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Disease, Shenyang 110002, China
| | - Ling Ren
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Disease, Shenyang 110002, China
| | - Yuyao Cheng
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Disease, Shenyang 110002, China
| | - Minghua Xu
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Disease, Shenyang 110002, China
| | - Wenji Luo
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Disease, Shenyang 110002, China
| | - Desong Zhan
- Department of Dental Materials Science, School and Hospital of Stomatology, China Medical University, Shenyang 110002, China
| | - Hidehiko Sano
- Department of Restorative Dentistry, Division of Oral Health Science, Faculty of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Kita-ku, Sapporo 060-8586, Japan
| | - Jiale Fu
- Department of Dental Materials Science, School and Hospital of Stomatology, China Medical University, Shenyang 110002, China
- Correspondence: ; Tel.: +86-15524002489
| |
Collapse
|
32
|
Klarić N, Macan M, Par M, Tarle Z, Marović D. Effect of Rapid Polymerization on Water Sorption and Solubility of Bulk-fill Composites. Acta Stomatol Croat 2022; 56:235-245. [PMID: 36382210 PMCID: PMC9635498 DOI: 10.15644/asc56/3/2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Indexed: 03/16/2025] Open
Abstract
OBJECTIVES The aim of the study was to examine the impact of rapid high-intensity polymerization on water sorption and solubility of a new generation of bulk-fill composite materials. MATERIAL AND METHODS Five materials were tested: a conventional composite Filtek Z250 (3M, St. Paul, USA) and four bulk-fill composites, Filtek One Bulk Fill (3M), Tetric PowerFill (Ivoclar Vivadent, Schaan, Liechtenstein), Tetric PowerFlow (Ivoclar Vivadent), SDR Plus (Dentsply, Konstanz, Germany). Composite specimens with a 9-mm diameter and a 2-mm height (n = 6) were polymerized with a high-intensity curing unit (Bluephase® PowerCure, Ivoclar Vivadent). The control group was polymerized for a total of 40 s on both sides (1193 mW / cm2) and 3s group for 3 s on one side (3053 mW/cm2). Water sorption and solubility were measured by ISO 4049 method up to 30 days of immersion. The results were statistically analyzed using one-way ANOVA with Tukey post-hoc correction. Different polymerization protocols for the same material were compared by t-test (p <0.05). RESULTS The 3s polymerization protocol increased the solubility of all materials. Filtek One Bulk Fill showed the highest water sorption and solubility values, and Tetric PowerFlow proved to be a stable material with low values of tested parameters. During immersion, a saturation of specimens was achieved in low-viscosity bulk-fill composites within two weeks, while in other materials it was not achieved within 30 days, or more, following the immersion. CONCLUSIONS Rapid polymerization caused an increase in solubility, which could affect the biocompatibility of the investigated materials not intended for the 3s curing. SDR Plus and Filtek One Bulk Fill should not be polymerized with rapid high-intensity curing due to increased solubility that exceeds ISO 4049:2009 limits.
Collapse
Affiliation(s)
- Nikolina Klarić
- Private Dental Practice, Petrovaradinska 7b, Zagreb, Croatia
| | - Matea Macan
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University Zagreb, Gunduliceva 5, Zagreb, Croatia
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University Zagreb, Gunduliceva 5, Zagreb, Croatia
| | - Zrinka Tarle
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University Zagreb, Gunduliceva 5, Zagreb, Croatia
| | - Danijela Marović
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University Zagreb, Gunduliceva 5, Zagreb, Croatia
| |
Collapse
|
33
|
de Oliveira NG, Espíndola-Castro LF, Rocha JC, de Barros Albuquerque AP, de Melo Rêgo MJB, de Melo Monteiro GQ, de Vasconcelos Carvalho M. Influence of the self-adhering strategy on microhardness, sorption, solubility, color stability, and cytotoxicity compared to bulk-fill and conventional resin composites. Clin Oral Investig 2022; 26:6663-6670. [PMID: 35916952 DOI: 10.1007/s00784-022-04624-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 07/11/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVES To analyze and compare, in vitro, the microhardness, sorption, solubility, color stability, and cytotoxicity of three types of resin composites: self-adhesive (SARC) (Dyad Flow (DF)/Kerr), bulk-fill (Filtek Bulk Fill Flow (FBF)/3 M ESPE), and conventional (Filtek Z350XT Flow (Z350)/3 M ESPE). MATERIALS AND METHODS Thirty cylindrical specimens were prepared using a split metal mold (15 mm × 1 mm), divided into 3 groups (n = 10) according to the material used. Vickers hardness (VH) was calculated from three indentations (300gf/15 s) per specimen. The sorption and solubility were measured according to the ISO 4049:2009 specification after storing in distilled water for 7 days. The color of each resin composite was measured using a portable digital spectrophotometer according to the CIELAB system. After a 7-day immersion in coffee, the color variation (∆E) was calculated. Following the ISO 10993:2012, the cytotoxicity in Vero cells was evaluated through the MTT assay. The results were analyzed using the Kruskal-Wallis test to compare the studied groups. The Wilcoxon test was used to compare the assessments in each studied group. For cytotoxicity analysis, the data were compared by the ANOVA test (α = 0.05). RESULTS DF showed the lowest VH (28.67), highest sorption (0.543 µg/mm3) and solubility (1.700 µg/mm3), and higher ∆E after 7 days of coffee immersion (p = 0.008). The resin composites studied were considered non-cytotoxic. CONCLUSIONS The SARC presented inferior mechanical and physical-chemical properties than bulk-fill and conventional resin composites, with comparable cytotoxicity against Vero cells. CLINICAL RELEVANCE The simplification of the clinical protocol of SARC can minimize the number of possible failures during the restorative technique. However, considering their inferior physical and mechanical properties, their coverage with materials of higher mechanical properties and physical-chemical stability should be considered.
Collapse
Affiliation(s)
- Natália Gomes de Oliveira
- Dental School, University of Pernambuco (FOP/UPE), Avenida Professor Luís Freire, 700, Cidade Universitária, Recife, PE, 50740-540, Brazil.
| | - Luís Felipe Espíndola-Castro
- Dental School, University of Pernambuco (FOP/UPE), Avenida Professor Luís Freire, 700, Cidade Universitária, Recife, PE, 50740-540, Brazil
| | - Julliana Carvalho Rocha
- Dental School, University of Pernambuco (Campus Arcoverde), Estrada Para Sítio Deserto, Arcoverde, PE, 1940, Brazil
| | | | - Moacyr Jesus Barreto de Melo Rêgo
- Biochemistry Department, Federal University of Pernambuco, Avenida Professor Moraes Rego, 1235, Cidade Universitária, Recife, PE, Brazil
| | - Gabriela Queiroz de Melo Monteiro
- Dental School, University of Pernambuco (FOP/UPE), Avenida Professor Luís Freire, 700, Cidade Universitária, Recife, PE, 50740-540, Brazil
| | - Marianne de Vasconcelos Carvalho
- Dental School, University of Pernambuco (FOP/UPE), Avenida Professor Luís Freire, 700, Cidade Universitária, Recife, PE, 50740-540, Brazil
| |
Collapse
|
34
|
An Evaluation of the Hydrolytic Stability of Selected Experimental Dental Matrices and Composites. MATERIALS 2022; 15:ma15145055. [PMID: 35888521 PMCID: PMC9322899 DOI: 10.3390/ma15145055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/08/2022] [Accepted: 07/17/2022] [Indexed: 01/27/2023]
Abstract
Materials with potential use as dental restoration should be evaluated in an aggressive environment. Such accelerated aging is widely used in other industries and allows the assessment of service life. In the presented study, three neat resins (UDMA/Bis-GMA/TEGDMA 70/10/20 wt.%, UDMA/Bis-GMA/TEGDMA 40/40/20 wt.% and UDMA/Bis-EMA/TEGDMA 40/40/20 wt.%) and three composites based on these matrices were tested before and after aging protocols (I-7500 cycles, 5 °C and 55 °C, water and 7 days, 60 °C, 0.1 M NaOH; II-5 days, 55 °C, water and 7 days, 60 °C, 0.1 M NaOH). Flexural strength (FS), diametral tensile strength (DTS) and hardness (HV) were determined. Applied aging protocols resulted in a decrease in the value of the FS, DTS and HV. Larger changes were noticed for the neat resins. Materials in which the content of bis-GMA was lower or substituted by bis-EMA showed better resistance to degradation. The choice of mixtures with monomers characterized by lower sorption values may favorably affect hydrolytic stability. It was shown that for composites there was a drastic decrease in hardness, which suggests a more superficial effect of the used protocols. However, degradation of the surface layer can result in a growing problem over time given that the mastication processes are an inherent element in the oral environment.
Collapse
|
35
|
Marovic D, Par M, Posavec K, Marić I, Štajdohar D, Muradbegović A, Tauböck TT, Attin T, Tarle Z. Long-Term Assessment of Contemporary Ion-Releasing Restorative Dental Materials. MATERIALS (BASEL, SWITZERLAND) 2022; 15:4042. [PMID: 35744101 PMCID: PMC9227571 DOI: 10.3390/ma15124042] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 06/02/2022] [Accepted: 06/03/2022] [Indexed: 02/05/2023]
Abstract
The objective was to evaluate new commercially available ion-releasing restorative materials and compare them to established anti-cariogenic materials. Four materials were tested: alkasite Cention (Ivoclar Vivadent) in self-cure or light-cure mode, giomer Beautifil II (Shofu), conventional glass-ionomer Fuji IX (GC), and resin composite Tetric EvoCeram (Ivoclar Vivadent) as a control. Flexural strength, flexural modulus, and Weibull modulus were measured one day, three months, and after three months with accelerated aging in ethanol. Water sorption and solubility were evaluated for up to one year. Degree of conversion was measured during 120 min for self-cured and light-cured Cention. In this study, Beautifil II was the ion-releasing material with the highest flexural strength and modulus and with the best resistance to aging. Alkasite Cention showed superior mechanical properties to Fuji IX. Weibull analysis showed that the glass-ionomer had the least reliable distribution of mechanical properties with the highest water sorption. The solubility of self-cured alkasite exceeded the permissible values according to ISO 4049. Degree of conversion of light-cured Cention was higher than in self-cure mode. The use of alkasite Cention is recommended only in the light-cure mode.
Collapse
Affiliation(s)
- Danijela Marovic
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia; (D.M.); (D.Š.); (Z.T.)
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia; (D.M.); (D.Š.); (Z.T.)
| | - Karlo Posavec
- Private Dental Practice, Dr. Ivana Novaka 28, 40000 Čakovec, Croatia;
| | - Ivana Marić
- Private Dental Practice, Odranska 10, 10000 Zagreb, Croatia;
| | - Dominik Štajdohar
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia; (D.M.); (D.Š.); (Z.T.)
| | - Alen Muradbegović
- Private Dental Practice, Malkočeva 3, 75000 Tuzla, Bosnia and Herzegovina;
| | - Tobias T. Tauböck
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland; (T.T.T.); (T.A.)
| | - Thomas Attin
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland; (T.T.T.); (T.A.)
| | - Zrinka Tarle
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia; (D.M.); (D.Š.); (Z.T.)
| |
Collapse
|
36
|
Photopolymerizable dental composite resins with lower shrinkage stress and improved hydrolytic and hygroscopic behavior with a urethane monomer used as an additive. J Mech Behav Biomed Mater 2022; 130:105189. [DOI: 10.1016/j.jmbbm.2022.105189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 03/14/2022] [Accepted: 03/18/2022] [Indexed: 11/15/2022]
|
37
|
Tanthanuch S, Kukiattrakoon B, Jantaravisoot J, Chanaphai C, Areewong C, Ampawa N. Degradability of bulk-fill resin composites after cyclic immersion in different distilled alcoholic beverages. J ESTHET RESTOR DENT 2022; 34:661-669. [PMID: 34837668 DOI: 10.1111/jerd.12848] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 11/18/2021] [Accepted: 11/18/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To investigate effect of distilled alcoholic beverages on surface hardness, roughness, and erosion of bulk-fill resin composites. MATERIALS AND METHODS Sixty eight specimens of each bulk-fill resin composite (Filtek One Bulk Fill Restorative, SonicFill 2, and Tetric N-Ceram Bulk Fill) were prepared. Baseline data of surface hardness and roughness value were recorded. The specimens were divided into five groups: vodka, whisky, tequila, brandy, and deionized water (served as a control). Specimens were then alternately immersed in 25 ml of a storage agent for 5 s and in 25 ml of artificial saliva for 5 s over 10 cycles. This process was repeated for 14 days. After immersion, specimens were subjected to evaluation of surface hardness, roughness, and erosion on days 7 and 14. The data were statistically analyzed by two-way repeated analysis of variance, Tukey's honestly significant difference, and a t test (p < 0.05). RESULTS Distilled alcoholic beverages caused significant hardness decrement, roughness and erosion increment (p < 0.05), where the greatest degradation was found in brandy group. Tetric N-Ceram Bulk Fill had the most significant decrement in hardness and increment in roughness and erosion than the other resin composites (p < 0.05). CONCLUSION Distilled alcoholic beverages affected hardness, roughness, and erosion of all the bulk-fill resin composites. CLINICAL SIGNIFICANCE Regarding the bulk-fill resin composites tested, Filtek One Bulk Fill Restorative was the most appropriate restorative material in patients who consume distilled alcoholic beverages.
Collapse
Affiliation(s)
- Saijai Tanthanuch
- Department of Conservative Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| | - Boonlert Kukiattrakoon
- Department of Conservative Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
- Dental Materials Research Unit (Second phase), Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| | - Janejira Jantaravisoot
- Department of Conservative Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| | - Chonnikan Chanaphai
- Department of Conservative Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| | - Chutikarn Areewong
- Department of Conservative Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| | - Nuthamol Ampawa
- Department of Conservative Dentistry, Faculty of Dentistry, Prince of Songkla University, Songkhla, Thailand
| |
Collapse
|
38
|
Szczesio-Wlodarczyk A, Fronczek M, Ranoszek-Soliwoda K, Grobelny J, Sokolowski J, Bociong K. The First Step in Standardizing an Artificial Aging Protocol for Dental Composites—Evaluation of Basic Protocols. Molecules 2022; 27:molecules27113511. [PMID: 35684448 PMCID: PMC9182013 DOI: 10.3390/molecules27113511] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 05/24/2022] [Accepted: 05/25/2022] [Indexed: 01/27/2023] Open
Abstract
The clinical performance of a dental restoration is strongly influenced by the complex and dynamically-changing oral environment; however, no standard procedure exists to evaluate this lifetime. This research provides an in-depth analysis of the effect of different aging procedures on the flexural strength (FS), diametral tensile strength (DTS) and hardness (HV) of selected dental materials (Resin F, Flow-Art and Arkon). Material structure was evaluated by scanning electron microscopy. It was found that each aging protocol had some influence on the tested properties, with continual erosion and degradation being observed. Greater mechanical degradation was observed for Resin F (neat resin) after the applied aging protocols, suggesting that a resin matrix is more susceptible for degradation. The most aggressive aging protocol was Protocol 5: 0.1 M NaOH, seven days, 60 °C. Further studies on the effect of artificial aging on dental materials should include a study of the thermal and chemical factors. A standardized aging procedure is crucial for improving the resistance of dental resin composite to oral conditions and their clinical performance.
Collapse
Affiliation(s)
- Agata Szczesio-Wlodarczyk
- University Laboratory of Materials Research, Medical University of Lodz, 92-213 Lodz, Poland
- Correspondence: ; Tel.: +48-42-272-54
| | - Magdalena Fronczek
- “DynamoLab” Academic Laboratory of Movement and Human Physical Performance, Medical University of Lodz, 92-213 Lodz, Poland;
- Department of Health Sciences, Medical University of Mazovia, 02-091 Warszawa, Poland
| | - Katarzyna Ranoszek-Soliwoda
- Department of Materials Technology and Chemistry, Faculty of Chemistry, University of Lodz, 90-236 Lodz, Poland; (K.R.-S.); (J.G.)
| | - Jarosław Grobelny
- Department of Materials Technology and Chemistry, Faculty of Chemistry, University of Lodz, 90-236 Lodz, Poland; (K.R.-S.); (J.G.)
| | - Jerzy Sokolowski
- Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland; (J.S.); (K.B.)
| | - Kinga Bociong
- Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland; (J.S.); (K.B.)
| |
Collapse
|
39
|
Physical and Mechanical Properties of Bulk-Fill, Conventional, and Flowable Resin Composites Stored Dry and Wet. Int J Dent 2022; 2022:7946239. [PMID: 35186087 PMCID: PMC8853813 DOI: 10.1155/2022/7946239] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 12/14/2021] [Accepted: 01/05/2022] [Indexed: 11/21/2022] Open
Abstract
Surface degradation, margin, and bulk fracture are common reasons that necessitate replacement of resin composite restorations. The purpose of this study was to determine filler weight (FW), fracture toughness (FT), Vickers hardness (VHN), sorption/solubility (S/S), and colour change (ΔE) of four resin composites in dry and wet conditions. Four resin composites of shade A2 were investigated: Aura bulk-fill (AB) (SDI), Tetric Evoceram (TE) (Ivoclar), G-ænial Universal Flo (GUF) (GC), and GC Kalore (GCK) (GC). For FT, VHN, and ΔE, the specimens were prepared, divided into 2 groups, and stored dry or immersed in distilled water. The specimens were subdivided into three subgroups and stored for 1, 7, and 60 days and then subjected to the relevant tests. Six fractured remnants were weighed for each material to measure FW%. To test S/S, ISO 4049 was used. The data were analysed using ANOVA and Tukey's test. There was an inverse correlation between FW and FT. A significantly higher FT was found for GUF. There were no significant differences between conditions in materials except for AB. The highest VHN was found for GCK and AB. After 1 and 7 days, a significant difference was observed in S/S between all materials with the highest values for GUF. There was a correlation between sorption and solubility. The material, the media, and aging have an influence on the properties of resin composites. It is important to emphasise that each material should be used for a specific clinical need based on their properties.
Collapse
|
40
|
Marovic D, Par M, Macan M, Klarić N, Plazonić I, Tarle Z. Aging-Dependent Changes in Mechanical Properties of the New Generation of Bulk-Fill Composites. MATERIALS 2022; 15:ma15030902. [PMID: 35160848 PMCID: PMC8839328 DOI: 10.3390/ma15030902] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 01/18/2022] [Accepted: 01/21/2022] [Indexed: 11/19/2022]
Abstract
This study evaluated the behavior of a new generation of bulk-fill resin composites after prolonged exposure to an aqueous environment and accelerated aging in ethanol. Six bulk-fill materials were tested (Tetric PowerFill, Filtek One Bulk Fill Restorative, Tetric EvoCeram Bulk Fill, Fill-Up!, Tetric PowerFlow, SDR Plus Bulk Fill Flowable) and compared to two conventional reference materials (Tetric EvoCeram and Tetric EvoFlow). Flexural strength, modulus, and Weibull parameters were examined at three time points: 1 day, 30 days, and 30 days followed by ethanol immersion. Degree of conversion after 30 days, water sorption, and solubility up to 90 days were also investigated. Filtek One Bulk Fill had the highest flexural strength and modulus among the tested materials, followed by Tetric PowerFill and SDR plus. Flexural strength and modulus of high-viscosity bulk-fill materials showed higher stability after accelerated aging in ethanol compared to their low-viscosity counterparts and reference materials. After 30 days, the degree of conversion was above 80% for all tested materials. Dual-cure material Fill-Up! was the best-cured material. The water sorption was highest for Fill-Up!, Filtek One Bulk Fill Restorative, and Tetric EvoFlow, while solubility was highest for Tetric EvoCeram. After aging in water and ethanol, new generation high-viscosity bulk-fill materials showed better mechanical properties than low-viscosity bulk-fill and conventional composites under extended light curing conditions.
Collapse
Affiliation(s)
- Danijela Marovic
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia; (M.M.); (I.P.); (Z.T.)
- Correspondence: (D.M.); (M.P.); Tel.: +385-1489-9203 (M.P.)
| | - Matej Par
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia; (M.M.); (I.P.); (Z.T.)
- Correspondence: (D.M.); (M.P.); Tel.: +385-1489-9203 (M.P.)
| | - Matea Macan
- Private Dental Practice, 10000 Zagreb, Croatia;
| | | | | | - Zrinka Tarle
- Department of Endodontics and Restorative Dental Medicine, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia; (M.M.); (I.P.); (Z.T.)
| |
Collapse
|
41
|
Vidal ML, Pecho OE, Collares K, Brandeburski S, Bona AD. Color Change of Resin-based Composites After In Vitro Bleaching Protocols: A Systematic Review and Meta-analysis. Oper Dent 2022; 47:149-162. [PMID: 35029690 DOI: 10.2341/20-234-lit] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/26/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To systematically review the literature on color stability of resin-based composites (RBC) after in vitro bleaching protocols and to assess the influence of bleaching protocols by meta-regression analysis on RBC color stability, and the association with clinical and experimental characteristics. METHODS The electronic search was conducted in MEDLINE/PubMed, Scopus, and Web of Science databases and included English language studies that evaluated and reported color differences (CIELAB values) of RBC after in vitro bleaching procedures using hydrogen peroxide and/or carbamide peroxide. RESULTS Database search for color change of RBC after bleaching retrieved 1335 eligible papers after removing duplicates. After initial screening, 66 articles were assessed for full-text reading with final inclusion of 23 published papers. A meta-regression analysis showed that storage time (p≤0.01), color measuring device (p≤0.01), and background color (p≤0.01) had influenced on color changes of RBC. The bleaching protocol (bleaching agent and time of application) did not influence on color changes of RBC (p>0.01). CONCLUSIONS There is evidence that RBC change color after bleaching, but the change is not clinically significant.
Collapse
Affiliation(s)
- M L Vidal
- Marina Lermenn Vidal, DDS, MS, PhD, Postgraduate Program in Dentistry, Dental School, University of Passo Fundo, Brazil
| | - O E Pecho
- Oscar E. Pecho, DDS, PhD, Postgraduate Program in Dentistry, Dental School, University of Passo Fundo, Brazil
| | - K Collares
- Kauê Collares, DDS, PhD, Postgraduate Program in Dentistry, Dental School, University of Passo Fundo, Brazil
| | - Sbn Brandeburski
- Suzane Boa Nova Brandeburski, DDS, MS, PhD, Postgraduate Program in Dentistry, Dental School, University of Passo Fundo, Brazil
| | - A Della Bona
- *Alvaro Della Bona, DDS, MMedSci, PhD, Postgraduate Program in Dentistry, Dental School, University of Passo Fundo, Brazil
| |
Collapse
|
42
|
Alhotan A, Yates J, Zidan S, Haider J, Jurado CA, Silikas N. Behaviour of PMMA Resin Composites Incorporated with Nanoparticles or Fibre following Prolonged Water Storage. NANOMATERIALS 2021; 11:nano11123453. [PMID: 34947803 PMCID: PMC8707186 DOI: 10.3390/nano11123453] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 12/15/2021] [Indexed: 11/25/2022]
Abstract
When PMMA denture base acrylics are exposed to oral environments for prolonged periods, the denture base absorbs water, which has a negative influence on the denture material and the degree to which the denture base will be clinically effective. This study assessed the water sorption, desorption, and hygroscopic expansion processes within PMMA denture-base resins reinforced with nanoparticles or fibre in comparison to the non-reinforced PMMA. The surfaces of the fillers were modified using a silane coupling agent (y-MPS) before mixing with PMMA. Group C consisted of specimens of pure PMMA whereas groups Z, T, and E consisted of PMMA specimens reinforced with ZrO2, TiO2 nanoparticles, or E-glass fibre, respectively. The reinforced groups were subdivided into four subgroups according to the percentage filler added to the PMMA resin by weight (1.5%, 3.0%, 5.0%, or 7.0%). Five specimens in disc shape (25 ± 1 mm × 2.0 ± 0.2 mm) were tested for each group. To assess water sorption and hygroscopic expansion, specimens from each group were individually immersed in water at 37 ± 1 °C for 180 days. The samples were then desorbed for 28 days at 37 ± 1 °C, to measure solubility. Water sorption and solubility were calculated using an electronic balance in accordance with ISO Standard 20795-1, and hygroscopic expansion was measured using a laser micrometre. Statistical analysis was undertaken at a p ≤ 0.05 significance level using a one-way ANOVA followed by Tukey post-hoc tests. The results demonstrated that the values of sorption (Wsp), mass sorption (Ms%), and % expansion within the tested groups reached equilibrium within 180 days. A noticeable difference was observed in groups Z and E for (Wsp)/(Ms%) compared to the Group C, but this was not significant. However, the difference between Group C and Group T for these measurements was significant. Non-significant differences also existed between each respective reinforced group and the control group in terms of hygroscopic expansion % values. During the 28-day desorption period, there were no differences in the values of solubility (Wsl)/mass desorption (Md%) between Group C and each of the reinforced tested groups. The findings indicate that the inclusion of ZrO2 nanoparticles or E-glass fibres does not increase the water solubility/sorption of the PMMA. However, modifying the PMMA with TiO2 did significantly increase the water sorption level.
Collapse
Affiliation(s)
- Abdulaziz Alhotan
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK; (J.Y.); (J.H.); (N.S.)
- Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh 11454, Saudi Arabia
- Correspondence:
| | - Julian Yates
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK; (J.Y.); (J.H.); (N.S.)
| | - Saleh Zidan
- Department of Dental Materials, Faculty of Dentistry, Sebha University, Sebha 18758, Libya;
| | - Julfikar Haider
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK; (J.Y.); (J.H.); (N.S.)
- Department of Engineering, Manchester Metropolitan University, Manchester M1 5GD, UK
| | - Carlos Alberto Jurado
- Woody L. Hunt School of Dental Medicine, Texas Tech University Health Sciences Centre El Paso, 5001 El Paso Drive, El Paso, TX 79905, USA;
| | - Nikolaos Silikas
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK; (J.Y.); (J.H.); (N.S.)
| |
Collapse
|
43
|
Alamoush RA, Salim NA, Silikas N, Satterthwaite JD. Long-term hydrolytic stability of CAD/CAM composite blocks. Eur J Oral Sci 2021; 130:e12834. [PMID: 34897842 DOI: 10.1111/eos.12834] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 09/29/2021] [Indexed: 01/17/2023]
Abstract
This study aimed to assess water sorption and solubility of CAD/CAM composite blocks compared to CAD/CAM ceramic after 8 months storage in water and artificial saliva. Eight CAD/CAM blocks were investigated: Five resin-composite blocks (RCBs), one polymer-infiltrated ceramic network (PICN) block, one ceramic-filled polyetheretherketone (PEEK) block, and one feldspathic ceramic block. One hundred and twelve specimens were prepared comprising 14 specimens of each of the eight materials. From each group of specimens, seven randomly selected specimens were immersed in 10 mL of water, while the other seven specimens were immersed in artificial saliva. All specimens were stored at 37°C and weighed at various time intervals. The data were analysed via repeat measures ANOVA, one-way ANOVA and Tukey's post hoc test (α = 0.05 for all tests). Sorption values (mean [SD]) in water were within the range -1.21 (0.4) to 39.3 (2.1) μg/mm3 and in artificial saliva between -0.7 (0.2) and 41.6 (1.3) μg/mm3 . Solubility values in water were between -0.43 (0.08) and 0.34 (0.18) μg/mm3 and in artificial saliva between -0.53 (0.07) μg/mm3 and 0.33 (0.2) μg/mm3 . CAD/CAM composite blocks were hydrolytically stable under long-term storage (according to ISO 4949:2009), although not as stable as ceramic. Water sorption of CAD/CAM composite blocks was dependent on the resin-matrix and was influenced by the filler weight %.
Collapse
Affiliation(s)
- Rasha A Alamoush
- Prosthodontics Department, School of Dentistry, University of Jordan, Amman, Jordan.,Dentistry, School of Medical Sciences, The University of Manchester, Manchester, UK
| | - Nesreen A Salim
- Prosthodontics Department, School of Dentistry, University of Jordan, Amman, Jordan
| | - Nick Silikas
- Dentistry, School of Medical Sciences, The University of Manchester, Manchester, UK
| | | |
Collapse
|
44
|
Flexural Property of a Composite Biomaterial in Three Applications. JOURNAL OF COMPOSITES SCIENCE 2021. [DOI: 10.3390/jcs5100282] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Resin composite is widely used in the dental field in clinics as a biomaterial. For example, it has been used as a composite material, a type of biomaterial, to repair caries and restore masticatory function, and as a luting agent to adhere the restoration to the tooth substrate. In order to demonstrate its function, we have measured the mechanical strength. From such basic research, we explain the potential of a dental material through the measurement of flexural strength and modulus of elasticity. In this research, we introduce commercial products that are actually used as composite materials suitable for tooth substrate and provide readers with their properties based on flexural strength and modulus of elasticity. In clinical performance, it might be advisable to delay polishing when a composite material is used for a luting material, a filling material and a core build-up material, as the flexural strength and the flexural modulus of elasticity were improved after 1 day of storage, and flexural strength and characteristics are considered as important mechanical properties of oral biomaterials.
Collapse
|
45
|
Karaca MK, Kam Hepdeniz O, Esencan Turkaslan B, Gurdal O. The effect of functionalized titanium dioxide nanotube reinforcement on the water sorption and water solubility properties of flowable bulk-fill composite resins. Odontology 2021; 110:313-328. [PMID: 34643837 DOI: 10.1007/s10266-021-00664-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Accepted: 10/04/2021] [Indexed: 02/19/2023]
Abstract
The aim of this study was to investigate the effects of titanium dioxide nanotube addition on the water sorption and water solubility values of different composite resins. Titanium dioxide nanotubes were synthesized from titanium dioxide powder in anatase form and in 13 nm diameter by hydrothermal process and then functionalized with methacrylic acid. Characterization of the nanotubes was performed by scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray diffraction and Fourier transform infrared spectroscopy. A flowable composite resin (Filtek Ultimate Flowable) and four flowable bulk-fill composite resins (Filtek Bulk Fill Flowable, SDR Bulk Fill Flowable, Venus Bulk Fill, X-tra Base) were tested. Two groups of each composite resin were prepared: groups of the resins without nanotubes; groups of the resins reinforced with 1.0 wt% functionalized titanium dioxide nanotube. Sorption and solubility in water were assessed according to ISO 4049 standards after 1, 7, 14, 21 days immersion periods. Data were analyzed using Mann-Whitney U and Kruskal-Wallis H tests (p < 0.05). Long cylindrical tubular structures with a diameter of 41.09-72.49 nm were observed in electron microscopy analysis. The band at 1636 cm - 1 showed the existence of the vinyl (C=C) bond of methacrylic acid coordinated to the nanotubes in Fourier transform infrared spectroscopy analysis. None of the materials tested in this study exceeded the maximum sorption and solubility values established by ISO. Regarding the water solubility, negative values were obtained. TiO2 nanotube reinforcement decreased the water sorption and solubility values significantly at different evaluation periods in all composite resins except for Venus (p < 0.05).
Collapse
Affiliation(s)
| | - Ozge Kam Hepdeniz
- Faculty of Dentistry, Department of Restorative Dentistry, Suleyman Demirel University, Isparta, Turkey.
| | - Banu Esencan Turkaslan
- Faculty of Engineering, Department of Chemical Engineering, Suleyman Demirel University, Isparta, Turkey
| | - Osman Gurdal
- Faculty of Medicine, Department of Biostatistics and Medical Informatics, Suleyman Demirel University, Isparta, Turkey
| |
Collapse
|
46
|
Gornig DC, Maletz R, Ottl P, Warkentin M. Influence of artificial aging: mechanical and physicochemical properties of dental composites under static and dynamic compression. Clin Oral Investig 2021; 26:1491-1504. [PMID: 34453210 PMCID: PMC8817055 DOI: 10.1007/s00784-021-04122-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 08/01/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The aim of the study was to evaluate the influence of filler content, degradation media and time on the mechanical properties of different dental composites after in vitro aging. MATERIALS AND METHODS Specimens (1 mm3) of three commercially available composites (GrandioSO®, Arabesk Top®, Arabesk Flow®) with respect to their filler content were stored in artificial aging media: artificial saliva, ethanol (60%), lactic acid (pH 5) and citric acid (pH 5). Parameters (Vickers microhardness, compressive strength, elastic modulus, water sorption and solubility) were determined in their initial state (control group, n = 3 for microhardness, n = 5 for the other parameters) and after 14, 30, 90 and 180 days (n = 3 for microhardness, n = 5 for the other parameters for each composite group, time point and media). Specimens were also characterized with dynamic-mechanical-thermal analysis (compression tests, F = ± 7 N; f = 0.5 Hz, 1 Hz and 3.3 Hz; t = 0-170 °C). RESULTS Incorporation of fillers with more than 80 w% leads to significantly better mechanical properties under static and dynamic compression tests and a better water sorption behavior, even after chemical degradation. The influence of degradation media and time is of subordinate importance for chemical degradation. CONCLUSION Although the investigated composites have a similar matrix, they showed different degradation behavior. Since dentine and enamel occur only in small layer thickness, a test specimen geometry with very small dimensions is recommended for direct comparison. Moreover, the use of compression tests to determine the mechanical parameters for the development of structure-compatible and functionally adapted composites makes sense as an additional standard. Clinical relevance Preferential use of highly filled composites for occlusal fillings is recommended.
Collapse
Affiliation(s)
- D. C. Gornig
- Dres. Irina & Thorsten Brandt, Orthodontic Practice, Wiesbaden, Germany
| | - R. Maletz
- Department of Material Science and Medical Engineering, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, Rostock, Germany
| | - P. Ottl
- Department of Prosthodontics and Material Science, Faculty of Medicine, University of Rostock, Rostock, Germany
| | - M. Warkentin
- Department of Material Science and Medical Engineering, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, Rostock, Germany
| |
Collapse
|
47
|
Evaluation of the Water Sorption and Solubility Behavior of Different Polymeric Luting Materials. Polymers (Basel) 2021; 13:polym13172851. [PMID: 34502891 PMCID: PMC8434010 DOI: 10.3390/polym13172851] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 08/19/2021] [Accepted: 08/20/2021] [Indexed: 11/28/2022] Open
Abstract
Objective: The study evaluated the water sorption (WSP) and water solubility (WSL) characteristics of different luting agents over a 180-day water storage period. Materials and Methods: Nine luting materials, i.e., conventional resin cement: Panavia F (PF), Rely X ARC (RA), self-adhesive resin cement: Rely X Unicem (RU), Breez (BZ), Maxcem Elite (MX), BisCem (BC) and resin-modified glass ionomer cement: FujiCem (FC), FujiPlus (FP) Rely X luting plus (RL) were assessed and fifty-two-disc specimens of each material were fabricated. All specimens were desiccated until a constant weight (W0) was reached. Thirteen specimens for each luting material were then randomly assigned to one of the four water immersion periods (7, 30, 90, and 180 days). After each period, the specimens were removed from the water and weighed to get W1. The samples were again desiccated for a second time and W2 was measured. Both WSP and WSL were determined by the following equations: WSP (%) = (W1 − W2) × 100/W0 and WSL (%) = (W0 − W2) × 100/W0. Assessments were performed following ISO standards. ANOVA was used to assess the effect of luting agent and time period on water sorption and solubility. Pair-wise comparisons were adjusted using Tukey’s multiple comparison procedure. A significance level of 0.05 was used for all statistical tests. Results: The highest mean WSP and WSL (WSP/WSL) were demonstrated by resin-modified glass-ionomers (RL 18.32/3.25, FC 17.08/4.83, and FP 14.14/1.99), while resin luting agents showed lower WSP and WSL results (PF 1.6/0.67 and RA 1.76/0.46), respectively. The self-adhesive agents exhibited a wide range of WSP and WSL values (RU 1.86/0.13, BZ 4.66/0.93, and MX 3.68/1.11). Self-adhesive cement showed lower WSP and WSL compared with the resin-modified glass-ionomers (p < 0.05). All the materials reached equilibrium after 90-days. Conclusions: Resin-based luting materials have the lowest sorption and solubility. Rely X Unicem self-adhesive luting materials were comparable to resin luting materials for WSL and WSP. Resin-modified glass-ionomer showed the highest water sorption and solubility compared with both resin and self-adhesive materials.
Collapse
|
48
|
Gallo C, Thomas SS, Selinger AJ, Hof F, Bohne C. Mechanism of a Disassembly-Driven Sensing System Studied by Stopped-Flow Kinetics. J Org Chem 2021; 86:10782-10787. [PMID: 34260247 DOI: 10.1021/acs.joc.1c00959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We carried out steady-state and stopped-flow photophysical measurements to determine the kinetics of a discrete disassembly driven turn-on fluorescent system. On and off rates for both DimerDye1 assembly and nicotine binding were determined. Relative rates for these competing processes provide insight on how this system can be optimized for sensing applications. Kinetics studies in artificial saliva showed that moving to more complex media has minimal effects on the sensing ability of the system.
Collapse
Affiliation(s)
- Cara Gallo
- Department of Chemistry and Centre for Advanced Materials and Related Technologies (CAMTEC), University of Victoria, P.O. Box 1700 STN CSC, Victoria, BC V8W 2Y2, Canada
| | - Suma S Thomas
- Department of Chemistry and Centre for Advanced Materials and Related Technologies (CAMTEC), University of Victoria, P.O. Box 1700 STN CSC, Victoria, BC V8W 2Y2, Canada
| | - Allison J Selinger
- Department of Chemistry and Centre for Advanced Materials and Related Technologies (CAMTEC), University of Victoria, P.O. Box 1700 STN CSC, Victoria, BC V8W 2Y2, Canada
| | - Fraser Hof
- Department of Chemistry and Centre for Advanced Materials and Related Technologies (CAMTEC), University of Victoria, P.O. Box 1700 STN CSC, Victoria, BC V8W 2Y2, Canada
| | - Cornelia Bohne
- Department of Chemistry and Centre for Advanced Materials and Related Technologies (CAMTEC), University of Victoria, P.O. Box 1700 STN CSC, Victoria, BC V8W 2Y2, Canada
| |
Collapse
|
49
|
Anti-bacterial and anti-microbial aging effects of resin-based sealant modified by quaternary ammonium monomers. J Dent 2021; 112:103767. [PMID: 34363889 DOI: 10.1016/j.jdent.2021.103767] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 07/23/2021] [Accepted: 07/26/2021] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVES Pit and fissure sealant is used in the prevention of dental caries. However, commercial pit and fissure sealant lacks persistent antibacterial properties. Dimethylaminododecyl methacrylate (DMADDM) was added to pit and fissure sealants to give it sustainable antibacterial properties and anti-microbial aging properties. METHODS Resin-based sealant was used as a control. Novel sealants were made with DMADDM. Atomic force microscope observation, curing depth, cytotoxicity, lactic acid measurement, hardness and microleakage were measured. Saliva-derived biofilms were grown on sealants. Biofilm metabolic activity, lactic acid production and biomass accumulation were measured. RESULTS Incorporating DMADDM did not increase the cytotoxicity or change the physical properties when the mass fraction of the DMADDM was 2.5-10%. The modification decreased the amount of bacterial biofilm, metabolic activity, lactic acid production and exopolysaccharide (EPS) in the saliva biofilms. It also provided anti-microbial aging properties. CONCLUSION The incorporation of DMADDM improved the antibacterial and anti-microbial aging effects of the material. It demonstrated a sustained antibacterial effect. The antibacterial and anti-microbial aging modification might be a potential choice for future clinical applications to inhibit dental caries, especially for children at high caries risk. CLINICAL SIGNIFICANCE The antibacterial and anti-microbial aging modification might be a potential choice for future clinical applications to prevent dental caries, especially for individuals at high caries risk.
Collapse
|
50
|
Ritto FP, da Silva EM, Borges ALS, Borges MAP, Sampaio-Filho HR. Fabrication and characterization of low-shrinkage dental composites containing montmorillonite nanoclay. Odontology 2021; 110:35-43. [PMID: 34156565 DOI: 10.1007/s10266-021-00629-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Accepted: 06/14/2021] [Indexed: 11/25/2022]
Abstract
Dental composites are aesthetic materials widely used in Dentistry for replacing hard dental tissues lost due to caries or traumas. The aim of this study was to fabricate low-shrinkage dental composite charged with nanoclay fillers (montmorillonite Cloisite®-MMT) and evaluate their cytotoxicity and physicomechanical properties. Four dental composites were produced from the same organic matrix: Bis-GMA/TEGDMA (30 wt.%). The filler system was constituted of BaSi, SiO2, and MMT in the following concentrations (wt.%): 93.8/6.2/0, 89.1/5.9/5, 86.7/5.8/7.5, and 84.4/5.6/10 (E0: 0; E5: 5%; E7.5: 7.5%; E10: 10% of MMT nanoclays). The following properties were tested: in vitro cytotoxicity, flexural strength, elastic modulus, volumetric shrinkage, water sorption, water solubility, and hygroscopic expansion. Scanning electron microscopy was used to characterize composites' topography. Data were analyzed by one-way ANOVA and Tukey's HSD post hoc test (p < 0.05). MMT nanoclays did not affect the cytotoxicity. E5 and E7.5 groups showed a significant decrease in polymerization shrinkage while maintained the overall physicomechanical properties. The inclusion of 5 and 7.5 wt.% of MMT nanoclays allowed the fabrication of dental composites with low cytotoxicity and low polymerization shrinkage, without jeopardizing the overall behaviour of their physicomechanical properties (flexural strength, elastic modulus, water sorption, water solubility, and hygroscopic expansion). These aspects suggest that the usage of MMT nanoclays could be an effective strategy to formulate new dental composites with clinical applicability.
Collapse
Affiliation(s)
- Fernanda Pitta Ritto
- Department of Operative Dentistry, College of Dentistry, Oklahoma University, Oklahoma, USA
| | - Eduardo Moreira da Silva
- Analytical Laboratory of Restorative Biomaterials-LABiom-R, Faculdade de Odontologia, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil
| | - Alexandre Luiz Souto Borges
- Department of Dental Materials and Prosthodontics, School of Dentistry, São Paulo State University-UNESP, São Jose Dos Campos, SP, Brazil
| | - Márcio Antônio Paraizo Borges
- Department of Operative Dentistry, IOPUC, Rua Marquês de São Vicente, 389-Gávea, Rio de Janeiro, RJ, 22451-047, Brazil.
| | | |
Collapse
|