1
|
Agathokleous S, Kedwell K, Casado C, Asbach C, Fonseca AS, Liisberg JB, Jensen SB, Jensen KA, Rodríguez JA, Karanasiou A, Lehmann M, Moreno T. Air quality in a bus depot and a way of improving it: effect of using air purifiers. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2025; 375:126310. [PMID: 40288630 DOI: 10.1016/j.envpol.2025.126310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2025] [Revised: 04/15/2025] [Accepted: 04/24/2025] [Indexed: 04/29/2025]
Abstract
This study assessed airborne particulate matter and black carbon concentrations and their distribution inside a restricted bus depot over two campaigns. Particles with a diameter <2.5 μm were evenly distributed across the depot, influenced by limited bus activity and the depot's spacious layout with three entrances and one exit, facilitating particle dispersion. Their average baseline concentration was 25.2 μg m-3, 4.6 times higher than outdoor levels, primarily driven by bus emissions and maintenance activities. Number concentrations of particles smaller than 0.3 μm (0.01-0.3 μm) averaged 1.3 × 103 particles cm-3, while larger particles (0.3-10 μm) averaged 33 × 100 particles cm-3. Black carbon averaged 1.3 μg m-3. Concentration peaks occurred from 23:00-9:00 and 16:00-18:00 due to bus activities, maintenance, and soil resuspension. The impact of air purifiers on air quality was also investigated focusing on their location, number, and air volume flow for optimal results. APs operating at half air volume flow and placed within 6 m of the measurement equipment achieved reductions of up to 45.2 % for PM2.5 and 73.6 % for particles sized 0.3-10 μm. However, air purifiers were much less effective for particles <0.3 μm. Crossed airflows and higher air volume flow decreased effectiveness due to turbulence and particle resuspension. This study underscores the need for optimized air purifiers placement, air volume flow settings, and operational strategies to mitigate air pollution in (semi-)closed transport environments like bus depots, improving air quality and health for passengers and workers.
Collapse
Affiliation(s)
- S Agathokleous
- Institute of Environmental Assessment and Water Research (IDAEA), CSIC, Barcelona, 08034, Spain; Dept. of Natural Resources and Environment, Industrial and TIC Engineering (EMIT-UPC), Manresa, 08242, Spain
| | - K Kedwell
- MANN+HUMMEL GmbH, Ludwigsburg, 71636, Germany
| | - C Casado
- CARTIF Technology Centre, Valladolid, 47151, Spain
| | - C Asbach
- Institute of Energy and Environmental Technoloy e. V. (IUTA), Duisburg, 47229, Germany
| | - A S Fonseca
- The National Research Centre for the Working Environment (NFA), 2100, Denmark
| | - J B Liisberg
- The National Research Centre for the Working Environment (NFA), 2100, Denmark
| | - S B Jensen
- The National Research Centre for the Working Environment (NFA), 2100, Denmark
| | - K A Jensen
- The National Research Centre for the Working Environment (NFA), 2100, Denmark
| | - J A Rodríguez
- Urban Buses of Valladolid, S.A. (AUVASA), Valladolid, 47008, Spain
| | - A Karanasiou
- Institute of Environmental Assessment and Water Research (IDAEA), CSIC, Barcelona, 08034, Spain
| | - M Lehmann
- MANN+HUMMEL GmbH, Ludwigsburg, 71636, Germany
| | - T Moreno
- Institute of Environmental Assessment and Water Research (IDAEA), CSIC, Barcelona, 08034, Spain.
| |
Collapse
|
2
|
Zhang JL, Liao GY, Lin HY, Xie JA, Li WC, Chen HC, Wu DW, Juan HL, Kuo JY, Chen PS. Enhancing indoor air quality and cardiopulmonary health in patients with asthma by photocatalytic oxidation and filters air cleaner. JOURNAL OF HAZARDOUS MATERIALS 2025; 482:136573. [PMID: 39581037 DOI: 10.1016/j.jhazmat.2024.136573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2024] [Revised: 10/23/2024] [Accepted: 11/17/2024] [Indexed: 11/26/2024]
Abstract
BACKGROUND Air purifiers can enhance indoor air quality and health outcomes, and studies have primarily focused on filters and particulate matter (PM) in households. Photocatalytic oxidation (PCO) is a promising technique for eliminating gaseous pollutants and bioaerosols. However, no field study was conducted in household. Therefore, this study evaluated the effects of the PCO and PCO + filters intervention on indoor air pollutants and cardiopulmonary endpoints in households. METHODS A randomized, double-blind crossover clinical trial was conducted. Indoor air pollutants, including PM, bioaerosols, and gaseous pollutants and cardiopulmonary endpoints including lung function, fractional exhaled nitric oxide (FeNO), respiratory symptoms, and blood pressure were assessed before and after intervention. FINDINGS This was the first study to evaluate the effects of PCO and PCO + filters interventions on indoor air pollutants and cardiopulmonary health in households. Indoor total volatile organic compounds (TVOC) and sulfur dioxides (SO2) significantly reduced after PCO intervention, however, we also observed the significant reduction in percentage of predicted values of forced vital capacity (FVC%) and forced expiratory volume in 3 s (FEV3%) and increased in FeNO after 13 days of PCO intervention. The PCO + filters intervention significantly reduced the levels of indoor PM1, PM2.5, PM4, PM10, total suspended particulate matter, ultrafine particles, airborne bacteria, fungi, endotoxin, mites, TVOC, nitrogen dioxide, and SO2, and marginal reduction in carbon monoxide. However, indoor carbon dioxide significantly increased after PCO/PCO + filters intervention. As for cardiopulmonary health, FVC%, and FEV1 % marginally increased 7 days after the PCO + filters intervention.
Collapse
Affiliation(s)
- Jia Lin Zhang
- Department of Public Health, College of Health Science, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC
| | - Guan-Yu Liao
- Department of Public Health, College of Health Science, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC
| | - Hong-Yi Lin
- Department of Public Health, College of Health Science, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC
| | - Jie-An Xie
- Department of Public Health, College of Health Science, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC
| | - Wan-Chen Li
- Department of Public Health, College of Health Science, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC
| | - Huang-Chi Chen
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan, ROC
| | - Da Wei Wu
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan, ROC
| | - Huai-Lei Juan
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan, ROC
| | - Jia-Yu Kuo
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan, ROC
| | - Pei-Shih Chen
- Department of Public Health, College of Health Science, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC; Institute of Environmental Engineering, College of Engineering, National Sun Yat-Sen University, Kaohsiung City, Taiwan, ROC; Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung City 807, Taiwan, ROC; Research Center for Precision Environmental Medicine, Kaohsiung Medical University, Kaohsiung City, Taiwan, ROC; Institute of Wildlife Conservation, College of Veterinary Medicine, National Pingtung University of Science and Technology, Pingtung City, Taiwan, ROC.
| |
Collapse
|
3
|
Kang J, Kim H, Jung JY, Huh JY, Ji HW, Lee SJ, Kim HC, Lee SW. Association between exposure to specific PM 2.5 constituents and environment, lifestyle, and clinical parameters in patients with COPD. INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH 2024:1-13. [PMID: 38909289 DOI: 10.1080/09603123.2024.2368724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 06/11/2024] [Indexed: 06/24/2024]
Abstract
This study investigated the correlation between the individual chemical constituents of particulate matter 2.5 μm (PM2.5) and respiratory parameters as well as the living environment and daily behaviors in patients with chronic obstructive pulmonary disease (COPD). Data were obtained from prospective COPD panel conducted in South Korea. Following collection via a microPEM, 18 metallic elements were determined using energy-dispersive X-ray fluorescence spectroscopy. All participants completed detailed questionnaires on living environments and lifestyle practices. Eighty-nine stable COPD patients (mean age 68.1 years; 94.4% male) were analyzed. Several constituents (titanium, aluminum, bromine, and silicone) were significantly associated with respiratory outcomes. Copper and manganese concentrations were significantly associated with the living environment. Increased ventilation time and air purifier operation were associated with lower concentrations of copper, silicone, barium, and titanium. These findings suggest varying relationships between PM2.5 constituents and clinical parameters in COPD patients, providing a basis for personalized interventions and future research.
Collapse
Affiliation(s)
- Jieun Kang
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Republic of Korea
| | - Hajeong Kim
- Division of Pulmonary, Allergy and Critical Care Medicine, Department of Internal Medicine, Hallym University Kangdong Sacred Heart Hospital, Seoul, Republic of Korea
| | - Ji Ye Jung
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jin-Young Huh
- Division of Pulmonary, Allergy and Critical Care Medicine, Chung-Ang University Gwangmyeong Medical Center, Gwangmyeong, Korea
| | - Hyun Woo Ji
- Division of Pulmonology, Department of Internal Medicine, National Health Insurance Service Ilsan Hospital, Goyang, Republic of Korea
| | - Seon-Jin Lee
- Environmental Disease Research Center, Korea Research Institute of Bioscience and Biotechnology, Daejeon, Republic of Korea
| | - Hwan-Cheol Kim
- Department of Occupational and Environmental Medicine, Inha University Hospital, Inha University College of Medicine, Incheon, Republic of Korea
| | - Sei Won Lee
- Department of Pulmonary and Critical Care Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
4
|
McIntyre AM, Scammell MK, Kinney PL, Khosla K, Benton L, Bongiovanni R, McCannon J, Milando CW. Portable Air Cleaner Usage and Particulate Matter Exposure Reduction in an Environmental Justice Community: A Pilot Study. ENVIRONMENTAL HEALTH INSIGHTS 2024; 18:11786302241258587. [PMID: 38863688 PMCID: PMC11165963 DOI: 10.1177/11786302241258587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 05/12/2024] [Indexed: 06/13/2024]
Abstract
Particulate matter (PM) exposure is associated with adverse health outcomes, including respiratory illness. A large fraction of exposure to airborne contaminants occurs in the home. This study, conducted over 5 months in a community with high asthma rates (Chelsea, MA, USA), investigated the use of portable air cleaners (PACs) to reduce indoor PM. Seven asthma-affected households participated, receiving a PAC (Austin Air Health Mate HEPA filter), a QuantAQ sensor to measure PM1, PM2.5, PM10 (µg/m3), and a HOBO plug-load data logger to track PAC usage. Results describe hourly and daily PM concentrations and PAC usage for each household. Hourly average PM concentrations decreased when PACs were turned on (vs. when they were turned off) across households during the study period: PM1 decreased by 0.46 µg/m3, PM2.5 decreased by 0.69 µg/m3, and PM10 decreased by 3.22 µg/m3. PAC usage varied for each household, including constant usage in one household and only usage at certain times of day in others. Higher filtration settings led to lower PM, with significant reductions in some, but not all, homes. Our findings highlight some difficulties in implementing household PAC interventions, yet also provide evidence to support household-level interventions to reduce PM and other indoor sources of air pollution. We also highlight academic-community partnerships as contributing to evidence-based solutions.
Collapse
Affiliation(s)
- Alina M McIntyre
- Department of Environmental Health, Boston University School of Public Health, Boston, MA, USA
| | - Madeleine K Scammell
- Department of Environmental Health, Boston University School of Public Health, Boston, MA, USA
| | - Patrick L Kinney
- Department of Environmental Health, Boston University School of Public Health, Boston, MA, USA
| | - Kiran Khosla
- Department of Environmental Health, Boston University School of Public Health, Boston, MA, USA
| | | | | | | | - Chad W Milando
- Department of Environmental Health, Boston University School of Public Health, Boston, MA, USA
| |
Collapse
|
5
|
Ebrahimifakhar A, Poursadegh M, Hu Y, Yuill DP, Luo Y. A systematic review and meta-analysis of field studies of portable air cleaners: Performance, user behavior, and by-product emissions. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 912:168786. [PMID: 38008326 DOI: 10.1016/j.scitotenv.2023.168786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 11/08/2023] [Accepted: 11/20/2023] [Indexed: 11/28/2023]
Abstract
Indoor air quality is important for the health of building occupants, and public interest in controlling indoor airborne pathogens increased dramatically with the COVID-19 pandemic. Pollutant concentrations can be controlled locally using portable air cleaners (sometimes called air purifiers), which allow occupants to apply air cleaning technology to meet their needs in the location and times that they find appropriate. This paper provides a systematic review of scientific literature that describes field studies of the effectiveness of portable air cleaners. Over 500 papers were considered, and 148 were reviewed in detail, to extract 35 specific research results (e.g., particulate removal performance) or characteristics (e.g., type of building). These were aggregated to provide an overview of results and approaches to this type of research, and to provide meta-analyses of the results. The review includes: descriptions of the geographical location of the research; rate of publications over time; types of buildings and occupants in the field study; types of air cleaner technology being tested; pollutants being measured; resulting pollutant removal effectiveness; patterns of usage and potential barriers to usage by occupants; and the potential for by-product emissions in some air cleaner technologies. An example result is that 83 of the 148 papers measured reductions in fine particulates (PM2.5) and found a mean reduction of 49 % with standard deviation of 20 %. The aggregated results were approximately normally distributed, ranging from finding no significant reduction up to a maximum above 90 % reduction. Sixteen of the 148 papers considered gaseous pollutants, such as volatile organic compounds, nitrogen dioxide, and ozone; 36 papers considered biological pollutants, such as bacteria, viruses, pollen, fungi, etc. An important challenge, common to several studies, is that occupants run the air cleaners for shorter periods and on low airflow rate settings, because of concerns about noise, drafts, and electricity cost, which significantly reduces air cleaning effectiveness.
Collapse
Affiliation(s)
- Amir Ebrahimifakhar
- Delos Labs, Delos, New York, NY 10014, USA; Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA.
| | - Mehrdad Poursadegh
- Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA.
| | - Yifeng Hu
- Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA; Buildings and Transportation Science Division, Oak Ridge National Laboratory, Oak Ridge, TN 37830, USA.
| | - David P Yuill
- Durham School of Architectural Engineering and Construction, University of Nebraska - Lincoln, 1110 S. 67th Street, Omaha, NE 68182, USA.
| | - Yu Luo
- Department of Applied Physics and Applied Mathematics, Columbia University, 500 W. 120th Street, New York, NY 10027, USA.
| |
Collapse
|
6
|
Chen CF, Hsu CH, Chang YJ, Lee CH, Lee DL. Efficacy of HEPA Air Cleaner on Improving Indoor Particulate Matter 2.5 Concentration. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:11517. [PMID: 36141811 PMCID: PMC9516965 DOI: 10.3390/ijerph191811517] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 09/09/2022] [Accepted: 09/12/2022] [Indexed: 06/16/2023]
Abstract
High-efficiency particulate air (HEPA) filters is a potential tool used to remove fine particles and improve indoor air quality. This study aims to analyze the real-world efficacy of portable HEPA air cleaners in a household environment. Laser light dispersion PM2.5 sensors are used to continuously monitor the indoor and outdoor PM2.5 level before and after HEPA air cleaner filtration. Overall, HEPA air cleaners significantly reduce the indoor PM2.5 level (33.5 ± 10.3 vs. 17.2 ± 10.7 µg/m3, mean difference (MD) = -16.3 µg/m3, p < 0.001) and indoor/outdoor PM2.5% (76.3 ± 16.8 vs. 38.6 ± 19.8%, MD = -37.7%, p < 0.001). The efficacy to reduce PM2.5 is strongest in three machines with medium-flow setting group (indoor PM2.5 MD: -26.5 µg/m3, indoor/outdoor PM2.5 percentage MD: -56.4%). Multiple linear regression demonstrates that outdoor PM2.5, machine number, airflow speed, and window ventilation are significant factors associated with indoor PM2.5 concentrations (R = 0.879) and percentage of the indoor/outdoor PM2.5 ratio (R = 0.808). HEPA air cleaners can effectively improve indoor PM2.5 air pollution. Adequate air cleaner machine numbers, appropriate airflow, and window ventilation limitations are important to achieve the best efficacy of the HEPA air cleaner.
Collapse
Affiliation(s)
- Chiu-Fan Chen
- Division of Chest Medicine, Kaohsiung Veterans General Hospital, Kaohsiung 813, Taiwan
| | - Chun-Hsiang Hsu
- Division of Chest Medicine, Kaohsiung Veterans General Hospital, Kaohsiung 813, Taiwan
| | - Yu-Jung Chang
- Kaohsiung and Pingtung Branch, National Health Insurance Administration, Ministry of Health and Welfare, Kaohsiung 801, Taiwan
| | - Chao-Hsien Lee
- Department of Nursing, Meiho University, Pingtung 912, Taiwan
| | - David Lin Lee
- Division of Chest Medicine, Kaohsiung Veterans General Hospital, Kaohsiung 813, Taiwan
- Department of Medicine, National Yang-Ming University, Taipei 112, Taiwan
| |
Collapse
|
7
|
Fazlzadeh M, Hassanvand MS, Nabizadeh R, Shamsipour M, Salarifar M, Naddafi K. Effect of portable air purifier on indoor air quality: reduced exposure to particulate matter and health risk assessment. ENVIRONMENTAL MONITORING AND ASSESSMENT 2022; 194:638. [PMID: 35925421 DOI: 10.1007/s10661-022-10255-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 06/28/2022] [Indexed: 06/15/2023]
Abstract
We sought to investigate the impact of air purifiers in the removal of particular matter (PM)10, PM2.5, PM1, and particle number concentration (PNC) in the indoor air of dormitories located at Iran's largest medical university, Tehran University of Medical Sciences. Twelve rooms were selected and randomly assigned to two rooms: sham air purifier system deployed room (SR) and true air purifier system deployed room (TR). All study samples were drawn simultaneously from assigned rooms using portable GRIMM dust monitors for 24 h. The PM monitors of air were positioned in the middle of each room next to the air purifier at the height of the breathing zone (1.5 m in height). The mean PM10, PM2.5, PM1, and PNC removal efficiency in rooms with and without a smoker were measured to be 40.7 vs 83.8%, 31.2 vs 78.4%, 29.9 vs 72.3%, and 44.3 vs 75.6%, respectively. The results showed that smoking is an important influencing factor on the indoor air quality; smoking lowered the removal efficiency of PM10, PM2.5, PM1, and PNC by 43%, 47%, 43%, and 31%, respectively. An air purifier could decline the PM10 and PM2.5 even lower than the WHO 24-h guideline level in non-smoker rooms. This study revealed that using household air purifiers in rooms with smokers and non-smokers significantly reduces the non-carcinogenic risks of exposure to PM10 and PM2.5.
Collapse
Affiliation(s)
- Mehdi Fazlzadeh
- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
- Center for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammad Sadegh Hassanvand
- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
- Center for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
| | - Ramin Nabizadeh
- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
- Center for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
| | - Mansour Shamsipour
- Department of Research Methodology and Data Analysis, Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
- Center for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran
| | - Mojtaba Salarifar
- Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Kazem Naddafi
- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
- Center for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
8
|
Yang X, Wang Q, Han F, Dong B, Wen B, Li L, Ruan H, Zhang S, Kong J, Zhi H, Wang C, Wang J, Zhang M, Xu D. Pulmonary Benefits of Intervention with Air Cleaner among Schoolchildren in Beijing: A Randomized Double-Blind Crossover Study. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:7185-7193. [PMID: 34491046 DOI: 10.1021/acs.est.1c03146] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
We conducted a crossover study employing air cleaner intervention among 125 schoolchildren aged 9-12 years in a boarding school in Beijing, China. The PM concentrations were monitored, and 27 biomarkers were analyzed. We used the linear mixed-effects model to evaluate the association of intervention/time-weighted PM concentrations with biomarkers. The outcomes showed that air cleaner intervention was associated with FeNO, exhaled breath condensate (EBC) IL-1β, and IL-6, which decreased by 12.57%, 10.83%, and 4.33%, respectively. Similar results were observed in the associations with PMs. Lag 1 day PMs had the strongest relationship with biomarkers, and significant changes were observed in biomarkers such as FEV1, FeNO, EBC 8-iso, and MCP-1. Boys showed higher percentage changes than girls, and the related biomarkers were FeNO, EBC 4-HNE, IL-1β, IL-6, and MCP-1. The results showed that biomarkers such as FeNO, EBC IL-6, MCP-1, and 4-HNE could sensitively reflect the early abnormal response of the respiratory system under short-term PM exposure among healthy schoolchildren and indicated that (1) air cleaners exert a protective effect on children's respiratory system. (2) PM had lag and cumulative effect, lag 1 day had the greatest effect. (3) The boys were more sensitive than the girls.
Collapse
Affiliation(s)
- Xiaoyan Yang
- Key Laboratory of Environment and Human Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
- Department of Environmental Toxicology, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
| | - Qin Wang
- Key Laboratory of Environment and Human Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
- Department of Air Quality and Health Monitoring, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
| | - Feng Han
- National Institute of Occupational Health and Poison Control, Chinese Center for Disease Control and Prevention, Beijing 100050, China
| | - Bin Dong
- Institute of Child and Adolescent Health, School of Public Health, Peking University, Beijing 100191, China
| | - Bo Wen
- Institute of Child and Adolescent Health, School of Public Health, Peking University, Beijing 100191, China
| | - Li Li
- Key Laboratory of Environment and Human Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
- Department of Environmental Toxicology, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
| | - Hongjie Ruan
- Key Laboratory of Environment and Human Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
- Department of Environmental Toxicology, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
| | - Shaoping Zhang
- Key Laboratory of Environment and Human Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
- Department of Environmental Toxicology, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
| | - Jian Kong
- Key Laboratory of Environment and Human Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
- Department of Environmental Toxicology, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
| | - Hong Zhi
- Key Laboratory of Environment and Human Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
- Department of Environmental Toxicology, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
| | - Chong Wang
- Key Laboratory of Environment and Human Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
- Department of Environmental Toxicology, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
| | - Jun Wang
- Key Laboratory of Environment and Human Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
- Department of Environmental Chemistry, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
| | - Ming Zhang
- Key Laboratory of Environment and Human Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
- Department of Environmental Toxicology, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
| | - Dongqun Xu
- Key Laboratory of Environment and Human Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
| |
Collapse
|
9
|
He L, Norris C, Cui X, Li Z, Barkjohn KK, Teng Y, Fang L, Lin L, Wang Q, Zhou X, Hong J, Li F, Zhang Y, Schauer JJ, Black M, Bergin MH, Zhang JJ. Oral cavity response to air pollutant exposure and association with pulmonary inflammation and symptoms in asthmatic children. ENVIRONMENTAL RESEARCH 2022; 206:112275. [PMID: 34710437 DOI: 10.1016/j.envres.2021.112275] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 09/28/2021] [Accepted: 10/22/2021] [Indexed: 06/13/2023]
Abstract
Exposure to fine particulate matter (PM2.5) and ozone (O3) may lead to inflammation and oxidative damage in the oral cavity, which is hypothesized to contribute to the worsening of airway inflammation and asthma symptoms. In this panel study of 43 asthmatic children aged 5-13 years old, each child had 4 clinic visits with a 2-week interval between two consecutive visits. At each visit, saliva samples were collected and subsequently analyzed for interleukin 6 (IL-6) and eosinophil cationic protein (ECP) as biomarkers of inflammation and malondialdehyde (MDA) as a biomarker of oxidative stress in the oral cavity. At each visit, children were measured for fractional exhaled nitric oxide (FeNO) as a marker of pulmonary inflammation. Asthma symptoms of these children were measured using the Childhood Asthma Control Test (C-ACT). We found that an interquartile range (IQR) increase in 24-h average personal exposure to PM2.5 measured 1 and 2 days prior was associated with increased salivary IL-6 concentration by 3.0% (95%CI: 0.2%-6.0%) and 4.2% (0.7%-8.0%), respectively. However, we did not find a clear association between personal O3 exposure and any of the salivary biomarkers, except for a negative association between salivary MDA and O3 exposure measured 1 day prior. An IQR increase in salivary IL-6 concentration was associated with significantly increased FeNO by 28.8% (4.3%-53.4%). In addition, we found that increasing salivary IL-6 concentrations were associated with decreased individual and total C-ACT scores, indicating the worsening of asthma symptoms. We estimated that 13.2%-22.2% of the associations of PM2.5 exposure measured 1 day prior with FeNO and C-ACT scores were mediated by salivary IL-6. These findings suggest that the induction of inflammation in the oral cavity may have played a role in linking air pollution exposure with the worsening of airway inflammation and asthma symptoms.
Collapse
Affiliation(s)
- Linchen He
- Nicholas School of the Environment, Duke University, Durham, NC, USA; Duke Global Health Institute, Duke University, Durham, NC, USA.
| | - Christina Norris
- Department of Civil and Environmental Engineering, Duke University, Durham, NC, USA.
| | - Xiaoxing Cui
- Nicholas School of the Environment, Duke University, Durham, NC, USA.
| | - Zhen Li
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China.
| | - Karoline K Barkjohn
- Department of Civil and Environmental Engineering, Duke University, Durham, NC, USA.
| | - Yanbo Teng
- Duke Kunshan University, Kunshan, Jiangsu Province, China.
| | - Lin Fang
- Department of Building Science, Tsinghua University, Beijing, China; Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China.
| | - Lili Lin
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China.
| | - Qian Wang
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China.
| | - Xiaojian Zhou
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China.
| | - Jianguo Hong
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China.
| | - Feng Li
- Department of Pulmonary Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.
| | - Yinping Zhang
- Department of Building Science, Tsinghua University, Beijing, China; Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China.
| | - James J Schauer
- Department of Civil and Environmental Engineering, College of Engineering, University of Wisconsin-Madison, Madison, WI, USA.
| | | | - Michael H Bergin
- Department of Civil and Environmental Engineering, Duke University, Durham, NC, USA.
| | - Junfeng Jim Zhang
- Nicholas School of the Environment, Duke University, Durham, NC, USA; Duke Global Health Institute, Duke University, Durham, NC, USA; Duke Kunshan University, Kunshan, Jiangsu Province, China.
| |
Collapse
|
10
|
Low-Cost Sensors for Air Quality Monitoring - the Current State of the Technology and a Use Overview. CHEMISTRY-DIDACTICS-ECOLOGY-METROLOGY 2022. [DOI: 10.2478/cdem-2021-0003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Abstract
In recent years the monitoring of air quality using cheap sensors has become an interesting alternative to conventional analytical techniques. Apart from vast price differences conventional techniques need to be performed by the trained personnel of commercial or research laboratories. Sensors capable of measuring dust, ozone, nitrogen and sulphur oxides, or other air pollutants are relatively simple electronic devices, which are comparable in size to a mobile phone. They provide the general public with the possibility to monitor air quality which can contribute to various projects that differ in regional scale, commercial funding or community-base. In connection with the low price of sensors arises the question of the quality of measured data. This issue is addressed by a number of studies focused on comparing the sensor data with the data of reference measurements. Sensory measurement is influenced by the monitored analyte, type and design of the particular sensor, as well as by the measurement conditions. Currently sensor networks serve as an additional source of information to the network of air quality monitoring stations, where the density of the network provides concentration trends in the area that may exceed specific measured values of pollutant concentrations and low uncertainty of reference measurements. The constant development of all types of sensors is leading to improvements and the difference in data quality between sensors and conventional monitoring techniques may be reduced.
Collapse
|
11
|
Zhu Y, Song X, Wu R, Fang J, Liu L, Wang T, Liu S, Xu H, Huang W. A review on reducing indoor particulate matter concentrations from personal-level air filtration intervention under real-world exposure situations. INDOOR AIR 2021; 31:1707-1721. [PMID: 34374125 DOI: 10.1111/ina.12922] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 06/28/2021] [Accepted: 07/30/2021] [Indexed: 05/28/2023]
Abstract
Improving air quality in indoor environments where people live is of importance to protect human health. In this systematic review, we assessed the effectiveness of personal-level use of air filtration units in reducing indoor particulate matters (PM) concentrations under real-world situations following systematic review guidelines. A total of 54 articles were included in the review, in which 20 randomized controlled/crossover trials that reported the changes in indoor fine PM (PM2.5 ) concentrations were quantitatively assessed in meta-analysis. Standardized mean differences (SMDs) were calculated for changes in indoor PM concentrations following air filtration interventions. Moderate-to-large reductions of 11%-82% in indoor PM2.5 concentrations were observed with SMD of -1.19 (95% CI: -1.50, -0.88). The reductions in indoor PM concentrations varied by geographical locations, filtration technology employed, indoor environmental characteristics, and air pollution sources. Most studies were graded with low-to-moderate risk of bias; however, the overall certainty of evidence for indoor PM concentration reductions was graded at very low level. Considering the effectiveness of indoor air filtration under practical uses, socio-economic disparities across study populations, and costs of air filter replacement over time, our results highlight the importance of reducing air pollution exposure at the sources.
Collapse
Affiliation(s)
- Yutong Zhu
- Department of Occupational and Environmental Health, Peking University School of Public Health, and Peking University Institute of Environmental Medicine, Beijing, China
- Key Laboratory of Molecular Cardiovascular Sciences of Ministry of Education, Health Science Center, Peking University, Beijing, China
| | - Xiaoming Song
- Department of Occupational and Environmental Health, Peking University School of Public Health, and Peking University Institute of Environmental Medicine, Beijing, China
- Key Laboratory of Molecular Cardiovascular Sciences of Ministry of Education, Health Science Center, Peking University, Beijing, China
| | - Rongshan Wu
- Department of Occupational and Environmental Health, Peking University School of Public Health, and Peking University Institute of Environmental Medicine, Beijing, China
- State Key Laboratory of Environmental Criteria and Risk Assessment, State Environmental Protection Key Laboratory of Ecological Effect and Risk Assessment of Chemicals, Chinese Research Academy of Environmental Sciences, Beijing, China
| | - Jiakun Fang
- Department of Occupational and Environmental Health, Peking University School of Public Health, and Peking University Institute of Environmental Medicine, Beijing, China
- Key Laboratory of Molecular Cardiovascular Sciences of Ministry of Education, Health Science Center, Peking University, Beijing, China
| | - Lingyan Liu
- Department of Occupational and Environmental Health, Peking University School of Public Health, and Peking University Institute of Environmental Medicine, Beijing, China
- Key Laboratory of Molecular Cardiovascular Sciences of Ministry of Education, Health Science Center, Peking University, Beijing, China
| | - Tong Wang
- Department of Occupational and Environmental Health, Peking University School of Public Health, and Peking University Institute of Environmental Medicine, Beijing, China
- Key Laboratory of Molecular Cardiovascular Sciences of Ministry of Education, Health Science Center, Peking University, Beijing, China
| | - Shuo Liu
- Department of Occupational and Environmental Health, Peking University School of Public Health, and Peking University Institute of Environmental Medicine, Beijing, China
- Section of Environmental Health, Department of Public Health, University of Copenhagen, Copenhagen, Denmark
| | - Hongbing Xu
- Department of Occupational and Environmental Health, Peking University School of Public Health, and Peking University Institute of Environmental Medicine, Beijing, China
- Key Laboratory of Molecular Cardiovascular Sciences of Ministry of Education, Health Science Center, Peking University, Beijing, China
| | - Wei Huang
- Department of Occupational and Environmental Health, Peking University School of Public Health, and Peking University Institute of Environmental Medicine, Beijing, China
- Key Laboratory of Molecular Cardiovascular Sciences of Ministry of Education, Health Science Center, Peking University, Beijing, China
| |
Collapse
|
12
|
Shi J, Zhao Y, Xue L, Li G, Wu S, Guo X, Wang B, Huang J. Urinary metabolites of polycyclic aromatic hydrocarbons after short-term fine particulate matter exposure: A randomized crossover trial of air filtration. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2021; 285:117258. [PMID: 33964555 DOI: 10.1016/j.envpol.2021.117258] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 04/01/2021] [Accepted: 04/24/2021] [Indexed: 06/12/2023]
Abstract
Research on the relationship between short-term exposure to fine particulate matter (PM2.5) and urinary metabolites of polycyclic aromatic hydrocarbons (PAHs) is sparse in the nonoccupationally exposed populations. A quasi-experimental observation of haze events nested within a randomized crossover trial of alternative 1-week real or sham indoor air filtration was conducted to evaluate the associations of urinary monohydroxy-PAHs (OH-PAHs) with short-term exposure to PM2.5 and PM2.5-bound PAHs. The study was conducted among 57 healthy college students in Beijing, China. PM2.5-bound PAHs and urinary OH-PAHs were quantified using gas chromatography coupled with a triple-quadrupole tandem mass spectrometer. Linear mixed-effect models were applied to evaluate the association of urinary OH-PAHs with time-weighted personal PM2.5 and PM2.5-bound PAHs, controlling for potentially confounding variables. The results demonstrated that air filtration could markedly reduce external exposure to PM2.5 and PM2.5-bound parent, nitrated, and oxygenated PAHs. In the intervention trial, the urinary concentrations of 2-hydroxyfluorene (2-OH-FLU) and 9-hydroxyphenanthrene (9-OH-PHE) were elevated significantly by 16.5% (95% CI, 2.1%, 33.1%) and 37.9% (95% CI, 8.4%, 75.4%), respectively, in association with a doubling increase in personal PM2.5 exposure. Urinary 9-OH-PHE was also significantly positively associated with the increase in the sum of PM2.5-bound parent PAHs. Furthermore, the levels of urinary OH-PAHs such as 2-OH-FLU and 9-OH-PHE in the haze events were elevated by 31.1% (95% CI, 8.7%, 53.4%) and 73.5% (95% CI, 16.0%, 131.0%), respectively, in association with a doubling increase in personal PM2.5 exposure. The findings indicated that urinary 2-OH-FLU and 9-OH-PHE could serve as potential internal exposure biomarkers for assessing short-term PM2.5 exposure in nonoccupational populations.
Collapse
Affiliation(s)
- Jiazhang Shi
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing, PR China
| | - Yan Zhao
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing, PR China
| | - Lijun Xue
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing, PR China
| | - Guoxing Li
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing, PR China
| | - Shaowei Wu
- Department of Occupational and Environmental Health, School of Public Health, Xi'an Jiaotong University Health Science Center, Xi'an, PR China
| | - Xinbiao Guo
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing, PR China
| | - Bin Wang
- Institute of Reproductive and Child Health, Peking University, Beijing, PR China; Department of Epidemiology and Biostatistics, School of Public Health, Peking University, Beijing, PR China
| | - Jing Huang
- Department of Occupational and Environmental Health Sciences, School of Public Health, Peking University, Beijing, PR China.
| |
Collapse
|
13
|
Yang YY, Fan L, Wang J, Zhu YD, Li X, Wang XQ, Yan X, Li L, Zhang YJ, Yang WJ, Yao XY, Wang XL. Characterization and exposure assessment of household fine particulate matter pollution in China. INDOOR AIR 2021; 31:1391-1401. [PMID: 33876854 DOI: 10.1111/ina.12843] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Revised: 04/07/2021] [Accepted: 04/08/2021] [Indexed: 06/12/2023]
Abstract
Household fine particulate matter (PM2.5 ) pollution greatly impacts residents' health. To explore the current national situation of household PM2.5 pollution in China, a study was conducted based on literature published from 1998 to 2018. After extracting data from the literature in conformity with the requirements, the nationwide household-weighted mean concentration of household PM2.5 (HPL) was calculated. Subgroup analyses of spatial, geographic, and temporal differences were also done. The estimated overall HPL in China was 132.2 ± 117.7 μg/m3 . HPL in the rural area (164.3 ± 104.5 μg/m3 ) was higher than that in the urban area (123.9 ± 122.3 μg/m3 ). For HPLs of indoor sampling sites, the kitchen was the highest, followed by the bedroom and living room. There were significant differences of geographic distributions. The HPLs in the South were higher than the North in four seasons. The inhaled dose of household PM2.5 among school-age children differed from provinces with the highest dose up to 5.9 μg/(kg·d). Countermeasures should be carried out to reduce indoor pollution and safeguard health urgently.
Collapse
Affiliation(s)
- Yu-Yan Yang
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Lin Fan
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Jiao Wang
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Yuan-Duo Zhu
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Xu Li
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Xin-Qi Wang
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Xu Yan
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Li Li
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Yu-Jing Zhang
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Wen-Jing Yang
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Xiao-Yuan Yao
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Xian-Liang Wang
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| |
Collapse
|
14
|
Yuk H, Yang S, Wi S, Kang Y, Kim S. Verification of particle matter generation due to deterioration of building materials as the cause of indoor fine dust. JOURNAL OF HAZARDOUS MATERIALS 2021; 416:125920. [PMID: 34492852 DOI: 10.1016/j.jhazmat.2021.125920] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 04/13/2021] [Accepted: 04/15/2021] [Indexed: 06/13/2023]
Abstract
Particles of fine dust are pollutants that adversely affect indoor air quality and exacerbate human respiratory diseases. The aging of the building was pointed out as a source of fine dust indoors. The aging of buildings has various causes of deterioration. During various deterioration, friction adversely affects the building floor finish. In this study, an accelerated friction deterioration device was used to confirm the generation of fine dust particles through the frictional deterioration of floor finishes in buildings. The study found that the concentration of fine dust particles attributed to deteriorating flooring was 327 mg/m3 in PM2.5 and 4828 mg/m3 in PM10 and confirmed that particle distribution differs depending on the surface of the flooring. Particles of 10 µm or less were observed through particle analysis. The study confirmed that fine dust particles did not diffuse in a specific direction and that the detected fine dust particles could be attributed to deterioration. Further research is needed on the detection of fine dust in degraded building finishing materials.
Collapse
Affiliation(s)
- Hyeonseong Yuk
- Department of Architecture and Architectural Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Sungwoong Yang
- Department of Architecture and Architectural Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Seunghwan Wi
- Department of Architecture and Architectural Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Yujin Kang
- Department of Architecture and Architectural Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Sumin Kim
- Department of Architecture and Architectural Engineering, Yonsei University, Seoul 03722, Republic of Korea.
| |
Collapse
|
15
|
He L, Norris C, Cui X, Li Z, Barkjohn KK, Teng Y, Fang L, Lin L, Wang Q, Zhou X, Hong J, Li F, Zhang Y, Schauer JJ, Black M, Bergin MH, Zhang JJ. Role of endogenous melatonin in pathophysiologic and oxidative stress responses to personal air pollutant exposures in asthmatic children. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 773:145709. [PMID: 33940766 DOI: 10.1016/j.scitotenv.2021.145709] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 01/29/2021] [Accepted: 02/03/2021] [Indexed: 06/12/2023]
Abstract
BACKGROUND Heightening oxidative stress and inflammation is an important pathophysiological mechanism underlying air pollution health effects in people with asthma. Melatonin can suppress oxidative stress and inflammation in pulmonary and circulatory systems. However, the role of melatonin in the oxidative stress and physiological responses to air pollution exposure has not been examined in children with asthma. METHODS In this panel study of 43 asthmatic children (5-13 years old), each child had 4 clinic visits with a 2-week interval between two consecutive visits. At each visit, urine samples were collected and subsequently analyzed for 6-sulfatoxymelatonin (aMT6s) as a surrogate of circulating melatonin and for malondialdehyde (MDA) and 8-hydroxy-2'-deoxyguanosine (8-OHdG) as two biomarkers of systemic oxidative stress. At each clinic visit, children were measured for pulmonary function and fractional exhaled nitric oxide (FeNO, a marker of pulmonary inflammation). None of the children reported to have taking melatonin supplementation. Concentrations of indoor and ambient PM2.5 and ozone (O3) were combined with individual time-activity data to calculate personal air pollutant exposures. RESULTS We found that interquartile range increases in urinary MDA and 8-OHdG concentrations were associated with significantly increased urinary aMT6s concentrations by 73.4% (95% CI: 52.6% to 97.0%) and 41.7% (22.8% to 63.4%), respectively. Increases in daily personal exposure to O3 and to PM2.5 were each associated with increased urinary aMT6s concentrations. Increasing urinary aMT6s concentrations were associated with decreased FeNO and resonant frequency, indicating improved airway inflammation and lung elasticity, respectively. CONCLUSION The results suggest that systemic oxidative stress heightened by air pollution exposure may stimulate melatonin excretion as a defense mechanism to alleviate the adverse effects.
Collapse
Affiliation(s)
- Linchen He
- Nicholas School of the Environment, Duke University, Durham, NC, USA; Duke Global Health Institute, Duke University, Durham, NC, USA
| | - Christina Norris
- Department of Civil and Environmental Engineering, Duke University, Durham, NC, USA
| | - Xiaoxing Cui
- Nicholas School of the Environment, Duke University, Durham, NC, USA
| | - Zhen Li
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Karoline K Barkjohn
- Department of Civil and Environmental Engineering, Duke University, Durham, NC, USA
| | - Yanbo Teng
- Duke Kunshan University, Kunshan, Jiangsu Province, China
| | - Lin Fang
- Department of Building Science, Tsinghua University, Beijing, China; Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - Lili Lin
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Qian Wang
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Xiaojian Zhou
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Jianguo Hong
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Feng Li
- Department of Pulmonary Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yinping Zhang
- Department of Building Science, Tsinghua University, Beijing, China; Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - James J Schauer
- Department of Civil and Environmental Engineering, College of Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | | | - Michael H Bergin
- Department of Civil and Environmental Engineering, Duke University, Durham, NC, USA
| | - Junfeng Jim Zhang
- Nicholas School of the Environment, Duke University, Durham, NC, USA; Duke Global Health Institute, Duke University, Durham, NC, USA; Duke Kunshan University, Kunshan, Jiangsu Province, China.
| |
Collapse
|
16
|
Fermo P, Artíñano B, De Gennaro G, Pantaleo AM, Parente A, Battaglia F, Colicino E, Di Tanna G, Goncalves da Silva Junior A, Pereira IG, Garcia GS, Garcia Goncalves LM, Comite V, Miani A. Improving indoor air quality through an air purifier able to reduce aerosol particulate matter (PM) and volatile organic compounds (VOCs): Experimental results. ENVIRONMENTAL RESEARCH 2021; 197:111131. [PMID: 33865819 DOI: 10.1016/j.envres.2021.111131] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 03/29/2021] [Accepted: 04/01/2021] [Indexed: 05/04/2023]
Abstract
The adverse effects of fine particulate matter (PM) and many volatile organic compounds (VOCs) on human health are well known. Fine particles are, in fact, those most capable of penetrating in depth into the respiratory system. People spend most of their time indoors where concentrations of some pollutants are sometimes higher than outdoors. Therefore, there is the need to ensure a healthy indoor environment and for this purpose the use of an air purifier can be a valuable aid especially now since it was demonstrated that indoor air quality has a high impact on spreading of viral infections such as that due to SARS-COVID19. In this study, we tested a commercial system that can be used as an air purifier. In particular it was verified its efficiency in reducing concentrations of PM10 (particles with aerodynamic diameter less than 10 μm), PM2.5 (particles with aerodynamic diameter less than 2.5 μm), PM1 (particles with aerodynamic diameter less than 1 μm), and particles number in the range 0.3 μm-10 μm. Furthermore, its capacity in reducing VOCs concentration was also checked. PM measurements were carried out by means of a portable optical particle counter (OPC) instrument simulating the working conditions typical of a household environment. In particular we showed that the tested air purifier significantly reduced both PM10 and PM2.5 by 16.8 and 7.25 times respectively that corresponds to a reduction of about 90% and 80%. A clear reduction of VOCs concentrations was also observed since a decrease of over 50% of these gaseous substances was achieved.
Collapse
Affiliation(s)
- Paola Fermo
- Department of Chemistry, University of Milan, Milan, 20133, Italy; Italian Society of Environmental Medicine, (SIMA), Milan, 20123, Italy.
| | - Begoña Artíñano
- Centre for Energy, Environment and Technologies (CIEMAT), Madrid, Spain
| | - Gianluigi De Gennaro
- Italian Society of Environmental Medicine, (SIMA), Milan, 20123, Italy; Department of Biology, University "Aldo Moro" of Bari, Bari, Italy
| | | | - Alessandro Parente
- Université Libre de Bruxelles, Ecole Polytechnique de Bruxelles, Bruxelles, Belgium
| | | | | | - Gianluca Di Tanna
- The George Institute for Global Health, Faculty of Medicine, University of New South Wales, Sydney, Australia
| | | | | | | | | | - Valeria Comite
- Department of Chemistry, University of Milan, Milan, 20133, Italy
| | - Alessandro Miani
- Italian Society of Environmental Medicine, (SIMA), Milan, 20123, Italy; Department of Environmental Science and Policy, University of Milan, Milan, Italy
| |
Collapse
|
17
|
Cheek E, Guercio V, Shrubsole C, Dimitroulopoulou S. Portable air purification: Review of impacts on indoor air quality and health. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 766:142585. [PMID: 33121763 DOI: 10.1016/j.scitotenv.2020.142585] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 09/16/2020] [Accepted: 09/18/2020] [Indexed: 05/22/2023]
Abstract
A systematic literature review was carried out to examine the impact of portable air purifiers (PAPs) on indoor air quality (PM2.5) and health, focussing on adults and children in indoor environments (homes, schools and offices). Analysed studies all showed reductions in PM2.5 of between 22.6 and 92.0% with the use of PAPs when compared to the control. Associations with health impacts found included those on blood pressure, respiratory parameters and pregnancy outcomes. Changes in clinical biochemical markers were also identified. However, evidence for such associations was limited and inconsistent. Health benefits from a reduction in PM2.5 would be expected as the cumulative body of scientific evidence from various cohort studies shows positive impacts of long-term reduction in PM2.5 concentrations. The current evidence demonstrates that using a PAP results in short-term reductions in PM2.5 in the indoor environment, which has the potential to offer health benefits.
Collapse
Affiliation(s)
- Emily Cheek
- Air Quality and Public Health Group, Environmental Hazards and Emergencies Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Harwell Campus, Didcot, Oxfordshire, United Kingdom
| | - Valentina Guercio
- Air Quality and Public Health Group, Environmental Hazards and Emergencies Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Harwell Campus, Didcot, Oxfordshire, United Kingdom
| | - Clive Shrubsole
- Air Quality and Public Health Group, Environmental Hazards and Emergencies Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Harwell Campus, Didcot, Oxfordshire, United Kingdom
| | - Sani Dimitroulopoulou
- Air Quality and Public Health Group, Environmental Hazards and Emergencies Department, Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Harwell Campus, Didcot, Oxfordshire, United Kingdom.
| |
Collapse
|
18
|
He L, Norris C, Cui X, Li Z, Barkjohn KK, Brehmer C, Teng Y, Fang L, Lin L, Wang Q, Zhou X, Hong J, Li F, Zhang Y, Schauer JJ, Black M, Bergin MH, Zhang JJ. Personal Exposure to PM 2.5 Oxidative Potential in Association with Pulmonary Pathophysiologic Outcomes in Children with Asthma. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:3101-3111. [PMID: 33555874 DOI: 10.1021/acs.est.0c06114] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Fine particulate matter (PM2.5) with a higher oxidative potential has been thought to be more detrimental to pulmonary health. We aim to investigate the associations between personal exposure to PM2.5 oxidative potential and pulmonary outcomes in asthmatic children. We measured each of the 43 asthmatic children 4 times for airway mechanics, lung function, airway inflammation, and asthma symptom scores. Coupling measured indoor and outdoor concentrations of PM2.5 mass, constituents, and oxidative potential with individual time-activity data, we calculated 24 h average personal exposures 0-3 days prior to a health outcome measurement. We found that increases in daily personal exposure to PM2.5 oxidative potential were significantly associated with increased small, large, and total airway resistance, increased airway impedance, decreased lung function, and worsened scores of individual asthma symptoms and the total symptom score. Among the PM2.5 constituents, organic matters largely of indoor origin contributed the greatest to PM2.5 oxidative potential. Given that the variability in PM2.5 oxidative potential was a stronger driver than PM2.5 mass for the variability in the respiratory health outcomes, it is suggested to reduce PM2.5 oxidative potential, particularly by reducing the organic matter constituent of indoor PM2.5, as a targeted source control strategy in asthma management.
Collapse
Affiliation(s)
- Linchen He
- Nicholas School of the Environment, Duke University, Durham, North Carolina 27708, United States
- Duke Global Health Institute, Duke University, Durham, North Carolina 27708, United States
| | - Christina Norris
- Department of Civil and Environmental Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Xiaoxing Cui
- Nicholas School of the Environment, Duke University, Durham, North Carolina 27708, United States
| | - Zhen Li
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 200240, People's Republic of China
| | - Karoline K Barkjohn
- Department of Civil and Environmental Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Collin Brehmer
- Department of Civil and Environmental Engineering, College of Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706,United States
| | - Yanbo Teng
- Duke Kunshan University, Kunshan, Jiangsu Province 215316, People's Republic of China
| | - Lin Fang
- Department of Building Science, Tsinghua University, Beijing, People's Republic of China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, People's Republic of China
| | - Lili Lin
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 200240, People's Republic of China
| | - Qian Wang
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 200240, People's Republic of China
| | - Xiaojian Zhou
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 200240, People's Republic of China
| | - Jianguo Hong
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 200240, People's Republic of China
| | - Feng Li
- Department of Pulmonary Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Yinping Zhang
- Department of Building Science, Tsinghua University, Beijing, People's Republic of China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, People's Republic of China
| | - James J Schauer
- Department of Civil and Environmental Engineering, College of Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706,United States
| | - Marilyn Black
- Underwriters Laboratories, Inc, Marietta, Georgia 30067, United States
| | - Michael H Bergin
- Department of Civil and Environmental Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Junfeng Jim Zhang
- Nicholas School of the Environment, Duke University, Durham, North Carolina 27708, United States
- Duke Global Health Institute, Duke University, Durham, North Carolina 27708, United States
- Duke Kunshan University, Kunshan, Jiangsu Province 215316, People's Republic of China
| |
Collapse
|
19
|
Thomas E, Brown J. Using Feedback to Improve Accountability in Global Environmental Health and Engineering. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:90-99. [PMID: 33305578 DOI: 10.1021/acs.est.0c04115] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Engineered environmental health interventions and services in low-income and resource-limited settings-such as water supply and treatment, sanitation, and cleaner household energy services-have had a less than expected record of sustainability and have sometimes not delivered on their potential to improve health. These interventions require both effectively functioning technologies as well as supporting financial, political, and human resource systems, and may depend on user behaviors as well as professionalized service delivery to reduce harmful exposures. In this perspective, we propose that the application of smarter, more actionable monitoring and decision support systems and aligned financial incentives can enhance accountability between donors, implementers, service providers, governments, and the people who are the intended beneficiaries of development programming. Made possible in part by new measurement techniques, including emerging sensor technologies, rapid impact evaluation, citizen science, and performance-based contracting, such systems have the potential to propel the development of solutions that can work over the long-term, allowing the benefits of environmental health improvements to be sustained in settings where they are most critical by improving trust and mutual accountability among stakeholders.
Collapse
Affiliation(s)
- Evan Thomas
- Mortenson Center in Global Engineering University of Colorado Boulder 4001 Discovery Drive, Suite N290 Boulder, Colorado, 80303 United States
| | - Joe Brown
- Department of Environmental Sciences and Engineering Gillings School of Global Public Health University of North Carolina at Chapel Hill Chapel Hill, North Carolina 27599 United States
| |
Collapse
|
20
|
Barkjohn KK, Norris C, Cui X, Fang L, Zheng T, Schauer JJ, Li Z, Zhang Y, Black M, Zhang JJ, Bergin MH. Real-time measurements of PM 2.5 and ozone to assess the effectiveness of residential indoor air filtration in Shanghai homes. INDOOR AIR 2021; 31:74-87. [PMID: 32649780 DOI: 10.1111/ina.12716] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 05/08/2020] [Accepted: 06/26/2020] [Indexed: 06/11/2023]
Abstract
Portable air cleaners are increasingly used in polluted areas in an attempt to reduce human exposure; however, there has been limited work characterizing their effectiveness at reducing exposure. With this in mind, we recruited forty-three children with asthma from suburban Shanghai and deployed air cleaners (with HEPA and activated carbon filters) in their bedrooms. During both 2-week filtration and non-filtration periods, low-cost PM2.5 and O3 air monitors were used to measure pollutants indoors, outdoors, and for personal exposure. Indoor PM2.5 concentrations were reduced substantially with the use of air cleaners, from 34 ± 17 to 10 ± 8 µg/m3 , with roughly 80% of indoor PM2.5 estimated to come from outdoor sources. Personal exposure to PM2.5 was reduced from 40 ± 17 to 25 ± 14 µg/m3 . The more modest reductions in personal exposure and high contribution of outdoor PM2.5 to indoor concentrations highlight the need to reduce outdoor PM2.5 and/or to clean indoor air in multiple locations. Indoor O3 concentrations were generally low (mean = 8±4 ppb), and no significant difference was seen by filtration status. The concentrations of pollutants and the air cleaner effectiveness were highly variable over time and across homes, highlighting the usefulness of real-time air monitors for understanding individual exposure reduction strategies.
Collapse
Affiliation(s)
| | - Christina Norris
- Civil and Environmental Engineering, Duke University, Durham, NC, USA
| | - Xiaoxing Cui
- Nicholas School of the Environment, Duke University, Durham, NC, USA
| | - Lin Fang
- School of Architecture, Tsinghua University, Beijing, China
| | - Tongshu Zheng
- Civil and Environmental Engineering, Duke University, Durham, NC, USA
| | - James J Schauer
- Civil and Environmental Engineering, University of Wisconsin at Madison, Madison, WI, USA
| | - Zhen Li
- Shanghai First People's Hospital, Shanghai Shi, China
| | - Yinping Zhang
- School of Architecture, Tsinghua University, Beijing, China
| | | | - Junfeng Jim Zhang
- Nicholas School of the Environment, Duke University, Durham, NC, USA
| | - Michael H Bergin
- Civil and Environmental Engineering, Duke University, Durham, NC, USA
| |
Collapse
|
21
|
Allen RW, Barn P. Individual- and Household-Level Interventions to Reduce Air Pollution Exposures and Health Risks: a Review of the Recent Literature. Curr Environ Health Rep 2020; 7:424-440. [PMID: 33241434 PMCID: PMC7749091 DOI: 10.1007/s40572-020-00296-z] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/04/2020] [Indexed: 02/06/2023]
Abstract
PURPOSE OF REVIEW We reviewed recent peer-reviewed literature on three categories of individual- and household-level interventions against air pollution: air purifiers, facemasks, and behavior change. RECENT FINDINGS High-efficiency particulate air/arresting (HEPA) filter air purifier use over days to weeks can substantially reduce fine particulate matter (PM2.5) concentrations indoors and improve subclinical cardiopulmonary health. Modeling studies suggest that the population-level benefits of HEPA filter air purification would often exceed costs. Well-fitting N95 and equivalent respirators can reduce PM2.5 exposure, with several randomized crossover studies also reporting improvements in subclinical cardiovascular health. The health benefits of other types of face coverings have not been tested and their effectiveness in reducing exposure is highly variable, depends largely on fit, and is unrelated to cost. Behavior modifications may reduce exposure, but there has been little research on health impacts. There is now substantial evidence that HEPA filter air purifiers reduce indoor PM2.5 concentrations and improve subclinical health indicators. As a result, their use is being recommended by a growing number of government and public health organizations. Several studies have also reported subclinical cardiovascular health benefits from well-fitting respirators, while evidence of health benefits from other types of facemasks and behavior changes remains very limited. In situations when emissions cannot be controlled at the source, such as during forest fires, individual- or household-level interventions may be the primary option. In most cases, however, such interventions should be supplemental to emission reduction efforts that benefit entire communities.
Collapse
Affiliation(s)
- Ryan W Allen
- Faculty of Health Sciences, Simon Fraser University, Burnaby, BC, Canada.
| | - Prabjit Barn
- Legacy for Airway Health, Vancouver Coastal Health, Vancouver, BC, Canada
| |
Collapse
|
22
|
Park S, Ra SW, Kang SY, Kim HC, Lee SW. Effect of particulate matter exposure on patients with COPD and risk reduction through behavioural interventions: the protocol of a prospective panel study. BMJ Open 2020; 10:e039394. [PMID: 33168558 PMCID: PMC7654133 DOI: 10.1136/bmjopen-2020-039394] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
INTRODUCTION Patients with chronic obstructive pulmonary disease (COPD) are vulnerable to particulate matter (PM) exposure which can increase acute exacerbations and hospitalisation. Interventions to avoid PM exposure are important but evidence-based guidance is lacking. This study aims to assess the impact of PM on lung function, quality of life and exacerbations in patients with COPD using a panel design study; it will also provide evidence for interventional measures to reduce harm from PM exposure. METHODS AND ANALYSIS A prospective panel study of patients with COPD aged ≥40 years will be conducted. Patients will be required to have a forced expiratory volume in one second <80% of the predicted value at enrolment. A total of 120 patients from three different regions will be enrolled, 60 from the metropolitan area, 30 from an industrialised area and 30 from a clean rural area. Clinical outcomes will be assessed through COPD assessment test scores, the St. George's Respiratory Questionnaire for patients with COPD and pulmonary function testing. Indoor and outdoor PM in the patients' environments will be measured using gravimetric and light scattering platforms. To estimate the individual dose of PM exposure, a time-activity diary, Geographic Information System and land use regression model will be combined in every season for 1 year. The correlation between PM exposure and the health status of patients with COPD will be evaluated. In addition, 40 patients with the lowest score of life behaviour score to reduce environmental PM exposure will be randomised to a control or intervention group, who will receive in-depth education on risk-reducing behaviours. ETHICS AND DISSEMINATION This study was approved by the Institutional Review Board of each site. The participants received comprehensive information and provided informed consent. The result of this study will be discussed in the form of conference presentations and peer-reviewed publications. TRIAL REGISTRATION NUMBER NCT04020237.
Collapse
Affiliation(s)
- Shinhee Park
- Pulmonary, Allergy and Critical Care medicine, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Republic of Korea
| | - Seung Won Ra
- Department of Internal Medicine, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Republic of Korea
| | - Sung Yoon Kang
- Department of Internal Medicine, Gachon University Gil Medical Center, Incheon, Republic of Korea
| | - Hwan-Cheol Kim
- Department of Occupational and Environmental Medicine, Inha University College of Medicine, Incheon, Republic of Korea
| | - Sei Won Lee
- Department of Pulmonology and Critical Care Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
23
|
Barkjohn KK, Norris C, Cui X, Fang L, He L, Schauer JJ, Zhang Y, Black M, Zhang J, Bergin MH. Children's microenvironmental exposure to PM 2.5 and ozone and the impact of indoor air filtration. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2020; 30:971-980. [PMID: 32963288 DOI: 10.1038/s41370-020-00266-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Revised: 09/04/2020] [Accepted: 09/11/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND In highly polluted urban areas, personal exposure to PM2.5 and O3 occur daily in various microenvironments. Identifying which microenvironments contribute most to exposure can pinpoint effective exposure reduction strategies and mitigate adverse health impacts. METHODS This work uses real-time sensors to assess the exposures of children with asthma (N = 39) in Shanghai, quantifying microenvironmental exposure to PM2.5 and O3. An air cleaner was deployed in participants' bedrooms where we hypothesized exposure could be most efficiently reduced. Monitoring occurred for two 48-h periods: one with bedroom filtration (portable air cleaner with HEPA and activated carbon filters) and the other without. RESULTS Children spent 91% of their time indoors with the majority spent in their bedroom (47%). Without filtration, the bedroom and classroom environments were the largest contributors to PM2.5 exposure. With filtration, bedroom PM2.5 exposure was reduced by 75% (45% of total exposure). Although filtration status did not impact O3, the largest contribution of O3 exposure also came from the bedroom. CONCLUSIONS Actions taken to reduce bedroom PM2.5 and O3 concentrations can most efficiently reduce total exposure. As real-time pollutant monitors become more accessible, similar analyses can be used to evaluate new interventions and optimize exposure reductions for a variety of populations.
Collapse
Affiliation(s)
- Karoline K Barkjohn
- Duke University, Civil and Environmental Engineering, 121 Hudson Hall, Box 90287, Durham, NC, 27708, USA.
| | - Christina Norris
- Duke University, Civil and Environmental Engineering, 121 Hudson Hall, Box 90287, Durham, NC, 27708, USA
| | - Xiaoxing Cui
- Duke University, Nicholas School of the Environment, 9 Circuit Dr, Durham, NC, 27710, USA
| | - Lin Fang
- Tsinghua University, School of Architecture, Beijing, 100084, China
| | - Linchen He
- Duke University, Nicholas School of the Environment, 9 Circuit Dr, Durham, NC, 27710, USA
| | - James J Schauer
- University of Wisconsin at Madison, Civil and Environmental Engineering, 1415 Engineering Dr, Madison, WI, 53706, USA
| | - Yinping Zhang
- Tsinghua University, School of Architecture, Beijing, 100084, China
| | - Marilyn Black
- Underwriters Laboratories Inc., 2211 Newmarket Parkway, Marietta, GA, 30067, USA
| | - Junfeng Zhang
- Duke University, Nicholas School of the Environment, 9 Circuit Dr, Durham, NC, 27710, USA
| | - Michael H Bergin
- Duke University, Civil and Environmental Engineering, 121 Hudson Hall, Box 90287, Durham, NC, 27708, USA
| |
Collapse
|
24
|
He L, Cui X, Li Z, Teng Y, Barkjohn KK, Norris C, Fang L, Lin L, Wang Q, Zhou X, Hong J, Li F, Zhang Y, Schauer JJ, Black M, Bergin MH, Zhang JJ. Malondialdehyde in Nasal Fluid: A Biomarker for Monitoring Asthma Control in Relation to Air Pollution Exposure. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:11405-11413. [PMID: 32822160 DOI: 10.1021/acs.est.0c02558] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Fine particulate matter (PM2.5) and ozone (O3) may exert oxidative damage in the nose, which is hypothesized to be associated with worsened asthma symptoms. This study, hence, is to explore whether an oxidative stress biomarker, malondialdehyde (MDA) in the nasal fluid, has the potential to aid personalized asthma control. In a panel study of 43 asthmatic children, 5-13 years old, each child was measured 4 times with a 2-week interval between consecutive clinic visits. At each visit, nasal fluid and urine samples were collected, and fractional exhaled nitric oxide (FeNO) was measured as a biomarker of pulmonary inflammation. In addition to nasal MDA, urinary MDA and 8-hydroxy-2'-deoxyguanosine (8-OHdG) were measured as biomarkers of systemic oxidative stress. We also assessed asthma symptoms using the Childhood Asthma-Control Test (C-ACT). We found that interquartile range (IQR) increases in 24 h average personal PM2.5 exposure (22.2-33.5 μg/m3), estimated 0 to 5 days prior to a clinic visit, were associated with increased nasal MDA concentrations by 38.6-54.9%. Similarly, IQR increases in 24 h average personal O3 exposure (7.7-8.2 ppb) estimated 2 to 4 days prior were associated with increased nasal MDA by 22.1-69.4%. Only increased PM2.5 exposure was associated with increased FeNO. Increased nasal MDA concentration was associated with decreased total and individual C-ACT scores, indicating worsening of asthma symptoms. However, no significant associations were observed between urinary MDA or 8-OHdG and C-ACT scores. The results confirm that oxidative stress plays an important role in linking air pollution exposure and adverse respiratory health effects. These findings support that MDA in the nasal fluid may serve as a useful biomarker for monitoring asthma status, especially in relation to PM2.5 and O3 exposures, two known risk factors of asthma exacerbation.
Collapse
Affiliation(s)
- Linchen He
- Nicholas School of the Environment, Duke University, Durham, North Carolina 27708, United States
- Global Health Institute, Duke University, Durham, North Carolina 27708, United States
| | - Xiaoxing Cui
- Nicholas School of the Environment, Duke University, Durham, North Carolina 27708, United States
| | - Zhen Li
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Yanbo Teng
- Global Health Research Center, Duke Kunshan University, Kunshan, Jiangsu Province 215316, China
| | - Karoline K Barkjohn
- Department of Civil and Environmental Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Christina Norris
- Department of Civil and Environmental Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Lin Fang
- Department of Building Science, Tsinghua University, Beijing 100084, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing 100084, China
| | - Lili Lin
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Qian Wang
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Xiaojian Zhou
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Jianguo Hong
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Feng Li
- Department of Pulmonary Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai 200030, China
| | - Yinping Zhang
- Department of Building Science, Tsinghua University, Beijing 100084, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing 100084, China
| | - James J Schauer
- Department of Civil and Environmental Engineering, College of Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States
| | - Marilyn Black
- Underwriters Laboratories, Inc, Marietta, Georgia 30067, United States
| | - Michael H Bergin
- Department of Civil and Environmental Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Junfeng Jim Zhang
- Nicholas School of the Environment, Duke University, Durham, North Carolina 27708, United States
- Global Health Institute, Duke University, Durham, North Carolina 27708, United States
- Global Health Research Center, Duke Kunshan University, Kunshan, Jiangsu Province 215316, China
| |
Collapse
|
25
|
Airborne Aerosols and Human Health: Leapfrogging from Mass Concentration to Oxidative Potential. ATMOSPHERE 2020. [DOI: 10.3390/atmos11090917] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The mass concentration of atmospheric particulate matter (PM) has been systematically used in epidemiological studies as an indicator of exposure to air pollutants, connecting PM concentrations with a wide variety of human health effects. However, these effects can be hardly explained by using one single parameter, especially because PM is formed by a complex mixture of chemicals. Current research has shown that many of these adverse health effects can be derived from the oxidative stress caused by the deposition of PM in the lungs. The oxidative potential (OP) of the PM, related to the presence of transition metals and organic compounds that can induce the production of reactive oxygen and nitrogen species (ROS/RNS), could be a parameter to evaluate these effects. Therefore, estimating the OP of atmospheric PM would allow us to evaluate and integrate the toxic potential of PM into a unique parameter, which is related to emission sources, size distribution and/or chemical composition. However, the association between PM and particle-induced toxicity is still largely unknown. In this commentary article, we analyze how this new paradigm could help to deal with some unanswered questions related to the impact of atmospheric PM over human health.
Collapse
|
26
|
Trifonov SV, Velichko VV, Tikhomirova NA, Shikhov VN, Morozov EA, Tikhomirov AA. Deep Physical-Chemical Purification of Gas Medium in Artificial Ecosystems. DOKL BIOCHEM BIOPHYS 2020; 492:112-116. [PMID: 32632585 DOI: 10.1134/s1607672920030059] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2019] [Revised: 02/07/2020] [Accepted: 02/11/2020] [Indexed: 11/23/2022]
Abstract
The results of experiments on application of a newly developed facility for oxidation of volatile organic compounds on a platinum catalyst are presented. The feasibility of using this method in artificial ecosystems as a whole and in mass exchange of closed biological-technical life support systems in particular is shown. The possibility of deep purification of gas emitted from the reactor of physical-chemical processing of organic wastes is demonstrated. Wheat growing experiment on using the facility for oxidation of volatile organic compounds in a sealed chamber was performed. No adverse effect of probable toxic oxidation products on wheat plants during a 4-day experiment was determined.
Collapse
Affiliation(s)
- S V Trifonov
- Institute of Biophysics, Siberian Branch, Russian Academy of Sciences, Krasnoyarsk, Russia. .,Reshetnev Siberian State University of Science and Technology, Krasnoyarsk, Russia.
| | - V V Velichko
- Institute of Biophysics, Siberian Branch, Russian Academy of Sciences, Krasnoyarsk, Russia.,Reshetnev Siberian State University of Science and Technology, Krasnoyarsk, Russia
| | - N A Tikhomirova
- Institute of Biophysics, Siberian Branch, Russian Academy of Sciences, Krasnoyarsk, Russia
| | - V N Shikhov
- Institute of Biophysics, Siberian Branch, Russian Academy of Sciences, Krasnoyarsk, Russia
| | - E A Morozov
- Institute of Biophysics, Siberian Branch, Russian Academy of Sciences, Krasnoyarsk, Russia
| | - A A Tikhomirov
- Institute of Biophysics, Siberian Branch, Russian Academy of Sciences, Krasnoyarsk, Russia.,Reshetnev Siberian State University of Science and Technology, Krasnoyarsk, Russia
| |
Collapse
|
27
|
He L, Li Z, Teng Y, Cui X, Barkjohn KK, Norris C, Fang L, Lin L, Wang Q, Zhou X, Hong J, Li F, Zhang Y, Schauer JJ, Black M, Bergin MH, Zhang JJ. Associations of personal exposure to air pollutants with airway mechanics in children with asthma. ENVIRONMENT INTERNATIONAL 2020; 138:105647. [PMID: 32172043 DOI: 10.1016/j.envint.2020.105647] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 02/28/2020] [Accepted: 03/08/2020] [Indexed: 06/10/2023]
Abstract
BACKGROUND The importance of airway mechanics has been increasingly recognized in pediatric asthma. However, no studies have examined responses of airway mechanics to air pollution exposure in asthmatic children. METHODS In this panel study involving indoor air filtration manipulation that created a large gradient of personal exposure to PM2.5, the airway mechanics and lung function of 43 asthmatic children 5-13 years old in a suburb of Shanghai were measured four times within 3 consecutive months. Concentrations of indoor and outdoor PM2.5 and ozone were coupled with individual time-activity data to calculate personal exposures. Linear mixed effects models were used to examine the relationships of personal exposure with indicators of airway mechanics and lung function, respectively. RESULTS An interquartile range (IQR) increase in 24-hour average PM2.5 personal exposure (30.3 µg/m3) in the prior day was associated with significant increases in small airway resistance (R5-R20) of 15.8%, total airway resistance (R5) of 6.3%, and airway inflammation (FeNO) of 9.6%. These associations were stronger in children with lower blood eosinophil counts (<450/µL). No significant associations were found between personal PM2.5 exposure and lung function. Low-level ozone exposure (daily maximum 8-hour exposure range 1.1-56.4 ppb) was not significantly associated with any of the outcomes. CONCLUSION Changes in personal PM2.5 exposure, partly enhanced by air filtration, were associated with significant changes in airway resistance and inflammation in children with asthma. These findings suggest the importance of reducing PM2.5 exposure, via personal air quality management, in improving airflow limitation in the airways, especially the small airways.
Collapse
Affiliation(s)
- Linchen He
- Nicholas School of the Environment and Duke Global Health Institute, Duke University, Durham, NC, USA; Duke Global Health Institute, Duke University, Durham, NC, USA
| | - Zhen Li
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yanbo Teng
- Global Health Research Center, Duke Kunshan University, Kunshan, Jiangsu Province, China
| | - Xiaoxing Cui
- Nicholas School of the Environment and Duke Global Health Institute, Duke University, Durham, NC, USA
| | - Karoline K Barkjohn
- Department of Civil and Environmental Engineering, Duke University, Durham, NC, USA
| | - Christina Norris
- Department of Civil and Environmental Engineering, Duke University, Durham, NC, USA
| | - Lin Fang
- Department of Building Science, Tsinghua University, Beijing, China; Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - Lili Lin
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Qian Wang
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Xiaojian Zhou
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Jianguo Hong
- Department of Pediatrics, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Feng Li
- Department of Pulmonary Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yinping Zhang
- Department of Building Science, Tsinghua University, Beijing, China; Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - James J Schauer
- Department of Civil and Environmental Engineering, College of Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | | | - Michael H Bergin
- Department of Civil and Environmental Engineering, Duke University, Durham, NC, USA
| | - Junfeng Jim Zhang
- Nicholas School of the Environment and Duke Global Health Institute, Duke University, Durham, NC, USA; Duke Global Health Institute, Duke University, Durham, NC, USA; Global Health Research Center, Duke Kunshan University, Kunshan, Jiangsu Province, China.
| |
Collapse
|
28
|
Liu M, Barkjohn KK, Norris C, Schauer JJ, Zhang J, Zhang Y, Hu M, Bergin M. Using low-cost sensors to monitor indoor, outdoor, and personal ozone concentrations in Beijing, China. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2020; 22:131-143. [PMID: 31714569 DOI: 10.1039/c9em00377k] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
High concentrations of ground-level ozone (O3) have been measured outdoors across China but there are limited measurements of O3 in microenvironments, including in homes, and for personal exposure. This highlights the need for cheaper methods to accurately make these measurements and to better capture fine-scale spatial variability in O3 across cities. With this in mind, we conducted a pilot study at six homes in Beijing, China, over 12 days to evaluate the use of portable, low-cost, time-resolved monitors for measuring O3 indoors and outdoors. We also assessed personal exposure for one adult in each home for two 48 hour periods using backpack-mounted monitors. Prior to and following sampling we collocated all monitors with a reference analyzer; we used data from these colocations to generate linear calibrations which we applied to all monitor data. Calibration slopes did not change significantly over the study although some intercepts differed. The average limit of detection (LOD) was 7.0 ppb, average root mean square error was 16.7 ppb, mean absolute error was 13.3 ppb and normalized root mean square error was 33%. Performance varied substantially between sensors, underscoring the importance of monitor-specific calibrations and determinations of measurement error. Outdoor concentrations varied spatially, with home-specific peak hourly averages of 32-165 ppb; indoor concentrations ranged from below the LOD to 15 ppb. Hour-averaged personal exposure was generally higher than O3 indoors, and at times exceeded ambient O3 indicating contributions to personal exposure from ambient sources of O3 away from the home. This work illustrates the feasibility of using these monitors to characterize distributions of O3 spatially and temporally when differences in concentrations are large, and outlines considerations for using these monitors to measure personal exposure.
Collapse
Affiliation(s)
- Meichen Liu
- Duke University, Civil and Environmental Engineering, Durham, NC, USA.
| | | | - Christina Norris
- Duke University, Civil and Environmental Engineering, Durham, NC, USA.
| | - James J Schauer
- University of Wisconsin at Madison, Civil and Environmental Engineering, Madison, Wisconsin, USA
| | - Junfeng Zhang
- Duke University, Nicholas School of the Environment, Durham, NC, USA
| | - Yinping Zhang
- Tsinghua University, School of Architecture, Beijing, China
| | - Min Hu
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing, 100871, China and Beijing Innovation Center for Engineering Sciences and Advanced Technology, Peking University, Beijing, 100871, China
| | - Michael Bergin
- Duke University, Civil and Environmental Engineering, Durham, NC, USA.
| |
Collapse
|
29
|
Fermo P, Comite V, Falciola L, Guglielmi V, Miani A. Efficiency of an Air Cleaner Device in Reducing Aerosol Particulate Matter (PM) in Indoor Environments. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 17:ijerph17010018. [PMID: 31861409 PMCID: PMC6982241 DOI: 10.3390/ijerph17010018] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Revised: 12/13/2019] [Accepted: 12/15/2019] [Indexed: 12/26/2022]
Abstract
Indoor air quality (IAQ) in household environments is mandatory since people spend most of their time in indoor environments. In order to guarantee a healthy environment, air purification devices are often employed. In the present work, a commercial household vacuum cleaner has been tested in order to verify its efficiency in reducing the mass concentration and particle number of aerosol particulate matter (PM). The efficiency has been tested measuring, while the instrument was working, PM10 (particles with aerodynamic diameter less than 10 μm), PM2.5 (particles with aerodynamic diameter less than 2.5 μm), PM1 (particles with aerodynamic diameter less than 1 μm), and 7 size-fractions in the range between 0.3 and >10 μm. Measurements have been carried out by means of a portable optical particle counter instrument and simulating the working conditions typical of a household environment. It has been found that the tested commercial device significantly reduces both PM concentrations and particle number, especially in the finest fraction, i.e., particles in the range 0.3–0.5 μm, allowing an improvement of indoor air quality.
Collapse
Affiliation(s)
- Paola Fermo
- Dipartimento di Chimica, Università degli Studi di Milano, 20133 Milano, Italy
- SIMA (Società Italiana di Medicina Ambientale), Via Monte Leone 2, 20149 Milano, Italy
- Correspondence: ; Tel.: +39-02-5031-4246
| | - Valeria Comite
- Dipartimento di Chimica, Università degli Studi di Milano, 20133 Milano, Italy
| | - Luigi Falciola
- Dipartimento di Chimica, Università degli Studi di Milano, 20133 Milano, Italy
- SIMA (Società Italiana di Medicina Ambientale), Via Monte Leone 2, 20149 Milano, Italy
| | - Vittoria Guglielmi
- Dipartimento di Chimica, Università degli Studi di Milano, 20133 Milano, Italy
| | - Alessandro Miani
- SIMA (Società Italiana di Medicina Ambientale), Via Monte Leone 2, 20149 Milano, Italy
- Dipartimento di Scienze e Politiche Ambientali, Università degli Studi di Milano, 20133 Milano, Italy
| |
Collapse
|
30
|
Lowther SD, Jones KC, Wang X, Whyatt JD, Wild O, Booker D. Particulate Matter Measurement Indoors: A Review of Metrics, Sensors, Needs, and Applications. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:11644-11656. [PMID: 31512864 DOI: 10.1021/acs.est.9b03425] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Many populations spend ∼90% of their time indoors, with household particulate matter being linked to millions of premature deaths worldwide. Particulate matter is currently measured using particle mass, particle number, and particle size distribution metrics, with other metrics, such as particle surface area, likely to be of increasing importance in the future. Particulate mass is measured using gravimetric methods, tapered element oscillating microbalances, and beta attenuation instruments and is best suited to use in compliance monitoring, trend analysis, and high spatial resolution measurements. Particle number concentration is measured by condensation particle counters, optical particle counters, and diffusion chargers. Particle number measurements are best suited to source characterization, trend analysis and ultrafine particle investigations. Particle size distributions are measured by gravimetric impactors, scanning mobility particle sizers, aerodynamic particle sizers, and fast mobility particle sizers. Particle size distribution measurements are most useful in source characterization and particulate matter property investigations, but most measurement options remain expensive and intrusive. However, we are on the cusp of a revolution in indoor air quality monitoring and management. Low-cost sensors have potential to facilitate personalized information about indoor air quality (IAQ), allowing citizens to reduce exposures to PM indoors and to resolve potential dichotomies between promoting healthy IAQ and energy efficient buildings. Indeed, the low cost will put this simple technology in the hands of citizens who wish to monitor their own IAQ in the home or workplace, to inform lifestyle decisions. Low-cost sensor networks also look promising as the solution to measuring spatial distributions of PM indoors, however, there are important sensor/data quality, technological, and ethical barriers to address with this technology. An improved understanding of epidemiology is essential to identify which metrics correlate most with health effects, allowing indoor specific PM standards to be developed and to inform the future of experimental applications.
Collapse
Affiliation(s)
- Scott D Lowther
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , United Kingdom
- State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry , Chinese Academy of Sciences , 511 Kehua Rd , Tianhe, Guangzhou 510640 , China
| | - Kevin C Jones
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , United Kingdom
| | - Xinming Wang
- State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry , Chinese Academy of Sciences , 511 Kehua Rd , Tianhe, Guangzhou 510640 , China
| | - J Duncan Whyatt
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , United Kingdom
| | - Oliver Wild
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , United Kingdom
| | - Douglas Booker
- NAQTS, Lancaster Environment Centre , Lancaster University , Lancaster , LA14YQ , United Kingdom
| |
Collapse
|
31
|
Norris C, Fang L, Barkjohn KK, Carlson D, Zhang Y, Mo J, Li Z, Zhang J, Cui X, Schauer JJ, Davis A, Black M, Bergin MH. Sources of volatile organic compounds in suburban homes in Shanghai, China, and the impact of air filtration on compound concentrations. CHEMOSPHERE 2019; 231:256-268. [PMID: 31129407 DOI: 10.1016/j.chemosphere.2019.05.059] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2019] [Revised: 05/03/2019] [Accepted: 05/07/2019] [Indexed: 06/09/2023]
Abstract
Air pollution in China is an ongoing concern, with subsets of the population (e.g., asthmatic children) especially susceptible to the associated health effects. In addition, people spend the majority of their time indoors, where pollutant composition may differ from the better characterized ambient environment. Although volatile organic compounds (VOCs) present health risks and have high concentrations indoors, their sources have not been thoroughly quantified in typical homes in suburban China. Similarly lacking is an understanding of how well a purifier with high efficiency particulate air and activated carbon filters can remove VOCs in a real-world setting in China. In this study, we a) quantified total VOCs (TVOC) and 900 + individual VOCs in 20 homes in China, b) identified potential sources of VOCs, and c) evaluated impacts of filtration. We used non-negative matrix factorization, a variable reduction technique, to identify sources. TVOC and individual compounds had higher concentrations indoors than outdoors (mean [range] indoors, filtration with pre-filter only: 302 [56-793] μg m-3; outdoors, entire study: 92 [26-629] μg m-3), indicating prevalent sources indoors. Many compounds detected have not, to our knowledge, been measured in homes in China. Some compounds (e.g., octanal, heptanal, ⍺-cedrene) were specific to the indoor environment, a few were ubiquitous (e.g., acetaldehyde, formaldehyde), and others were detected infrequently. These compounds may originate from consumer products, solvents, vehicle emissions, a hexane source, wooden products, and cooking. Filtration may improve air quality indoors by lowering concentrations of some VOCs, and, specifically, contributions related to solvents and consumer products.
Collapse
Affiliation(s)
- Christina Norris
- Duke University, Civil and Environmental Engineering, 121 Hudson Hall, Durham, NC, 27708, USA.
| | - Lin Fang
- Tsinghua University, School of Architecture, Beijing, 100084, China; Beijing Key Lab of Indoor Air Quality Evaluation and Control, Beijing, 100084, China
| | - Karoline K Barkjohn
- Duke University, Civil and Environmental Engineering, 121 Hudson Hall, Durham, NC, 27708, USA
| | - David Carlson
- Duke University, Civil and Environmental Engineering, 121 Hudson Hall, Durham, NC, 27708, USA
| | - Yinping Zhang
- Tsinghua University, School of Architecture, Beijing, 100084, China; Beijing Key Lab of Indoor Air Quality Evaluation and Control, Beijing, 100084, China
| | - Jinhan Mo
- Tsinghua University, School of Architecture, Beijing, 100084, China; Beijing Key Lab of Indoor Air Quality Evaluation and Control, Beijing, 100084, China
| | - Zhen Li
- Department of Pediatrics, Shanghai General Hospital, Shanghai, 201620, China
| | - Junfeng Zhang
- Duke University, Nicholas School of the Environment, 9 Circuit Dr., Durham, NC, 27710, USA
| | - Xiaoxing Cui
- Duke University, Nicholas School of the Environment, 9 Circuit Dr., Durham, NC, 27710, USA
| | - James J Schauer
- University of Wisconsin at Madison, Civil and Environmental Engineering, 1415 Engineering Dr., Madison, WI, 53706, USA
| | - Aika Davis
- Underwriters Laboratories Inc., Chemical Safety, 2211 Newmarket Parkway, Suite 106, Marietta, GA, 30067, USA
| | - Marilyn Black
- Underwriters Laboratories Inc., Chemical Safety, 2211 Newmarket Parkway, Suite 106, Marietta, GA, 30067, USA
| | - Michael H Bergin
- Duke University, Civil and Environmental Engineering, 121 Hudson Hall, Durham, NC, 27708, USA
| |
Collapse
|
32
|
Cao M, Gu F, Rao C, Fu J, Zhao P. Improving the electrospinning process of fabricating nanofibrous membranes to filter PM2.5. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 666:1011-1021. [PMID: 30970468 DOI: 10.1016/j.scitotenv.2019.02.207] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Revised: 02/13/2019] [Accepted: 02/13/2019] [Indexed: 05/12/2023]
Abstract
To mitigate PM2.5 emissions is becoming a pressing concern, because these particles pose a threat to public health. Evidence shows that bead-free nanofiber with diameter of <100 nm is more likely to capture the PM2.5, however, currently it is impossible to fabricate bead-free nanofiber with such diameter without introduction of other substances. To fabricate bead-free polyacrylonitrile (PAN) nanofibers with diameter of <100 nm, we improved the electrospinning process of membrane fabrication via design of experiment (DOE), and we then used these nanofibers to filter PM2.5 emissions from burning cigarettes and fused deposition modeling (FDM) three-dimensional (3D) printing. The DOE was based on a L27 (313) orthodoxy array, which consists of six controllable factors, that is, the concentration of solution, the spinning voltage, the rotating speed, the tip-to-collector distance, the flow rate of the syringe pump, and the electrospinning temperature, each of them has three levels. The results showed that the nanofibers of the least diameter (i.e., 77 nm) can be fabricated under the following condition: 8 wt% PAN solution, 12 kV voltage, 5000 r/min, 12 cm tip-to-collector distance, 0.6 ml/h flow rate, and 50 °C electrospinning temperature. Range analysis and analysis of variance (ANOVA) showed that the concentration of PAN solution has the most significant effect on the diameter, and their values are positively correlated. An examination in a two-chamber filtering device showed the PAN membrane with the least fiber diameter has a PM2.5 filtration efficiency of 99.26%. A filtration test on standard FDM 3D printing process showed the membrane has a PM2.5 removal efficiency of 81.16%. This work could mitigate PM2.5 emissions from cigarette tobacco and FDM 3D printing, and it would be used to other scenarios, such as industrial and traffic emissions.
Collapse
Affiliation(s)
- Mingyi Cao
- The State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China; The Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Fu Gu
- The State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China; Department of Industrial and System Engineering, Zhejiang University, Hangzhou 310027, China; National Institute of Innovation Management, Zhejiang University, Hangzhou 310027, China
| | - Chengchen Rao
- The State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China; The Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Jianzhong Fu
- The State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China; The Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Peng Zhao
- The State Key Laboratory of Fluid Power and Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China; The Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China.
| |
Collapse
|