Strohmaier-Nguyen D, Horn C, Baeumner AJ. NT-proBNP detection with a one-step magnetic lateral flow channel assay. Anal Bioanal Chem 2024:10.1007/s00216-024-05223-x. [PMID: 38459191 DOI: 10.1007/s00216-024-05223-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 02/07/2024] [Accepted: 02/13/2024] [Indexed: 03/10/2024]
Abstract
Point-of-care sensors targeting blood marker analysis must be designed to function with very small volumes since acquiring a blood sample through a simple, mostly pain-free finger prick dramatically limits the sample size and comforts the patient. Therefore, we explored the potential of converting a conventional lateral flow assay (LFA) for a significant biomarker into a self-contained and compact polymer channel-based LFA to minimize the sample volume while maintaining the analytical merits. Our primary objective was to eliminate the use of sample-absorbing fleece and membrane materials commonly present in LFAs. Simultaneously, we concentrated on developing a ready-to-deploy one-step LFA format, characterized by dried reagents, facilitating automation and precise sample transport through a pump control system. We targeted the detection of the heart failure biomarker NT-proBNP in only 15 µL human whole blood and therefore implemented strategies that ensure highly sensitive detection. The biosensor combines streptavidin-functionalized magnetic beads (MNPs) as a 3D detection zone and fluorescence nanoparticles as signal labels in a sandwich-based immunoassay. Compared to the currently commercialized LFA, our biosensor demonstrates comparable analytical performance with only a tenth of the sample volume. With a detection limit of 43.1 pg∙mL-1 and a mean error of 18% (n ≥ 3), the biosensor offers high sensitivity and accuracy. The integration of all-dried long-term stable reagents further enhances the convenience and stability of the biosensor. This lateral flow channel platform represents a promising advancement in point-of-care diagnostics for heart failure biomarkers, offering a user-friendly and sensitive platform for rapid and reliable testing with low finger-prick blood sample volumes.
Collapse
Affiliation(s)
- Dan Strohmaier-Nguyen
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053, Regensburg, Germany
| | - Carina Horn
- Roche Diagnostics GmbH, 68305, Mannheim, Germany
| | - Antje J Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053, Regensburg, Germany.
| |
Collapse
|
2
|
Uygun M, Doganci E, Tasdelen MA, Gurek AG. One‐pot photoinduced synthesis of dansyl containing acrylamide hydrogels and their chemosensing properties. J Appl Polym Sci 2019. [DOI: 10.1002/app.47096] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- M. Uygun
- Department of ChemistryGebze Technical University 41400 Kocaeli Turkey
| | - E. Doganci
- Department of Chemistry and Chemical Processing TechKocaeli University 41140 Kocaeli Turkey
| | - M. A. Tasdelen
- Faculty of Engineering, Department of Polymer EngineeringYalova University 77100 Yalova Turkey
| | - A. G. Gurek
- Department of ChemistryGebze Technical University 41400 Kocaeli Turkey
| |
Collapse
|
3
|
Henderson CJ, Pumford E, Seevaratnam DJ, Daly R, Hall EAH. Gene to diagnostic: Self immobilizing protein for silica microparticle biosensor, modelled with sarcosine oxidase. Biomaterials 2019; 193:58-70. [PMID: 30562636 DOI: 10.1016/j.biomaterials.2018.12.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Revised: 11/07/2018] [Accepted: 12/07/2018] [Indexed: 02/08/2023]
Abstract
A rational design approach is proposed for a multifunctional enzyme reagent for point-of-care diagnostics. The biomaterial reduces downstream isolation steps and eliminates immobilization coupling chemicals for integration in a diagnostic platform. Fusion constructs combined the central functional assay protein (e.g. monomeric sarcosine oxidase, mSOx, horseradish peroxidase, HRP), a visualizing protein (e.g. mCherry) and an in-built immobilization peptide (e.g. R5). Monitoring protein expression in E.coli was facilitated by following the increase in mCherry fluorescence, which could be matched to a color card, indicating when good protein expression has occurred. The R5 peptide (SSKKSGSYSGSKGSKRRIL) provided inbuilt affinity for silica and an immobilization capability for a silica based diagnostic, without requiring additional chemical coupling reagents. Silica particles extracted from beach sand were used to collect protein from crude protein extract with 85-95% selective uptake. The silica immobilized R5 proteins were stable for more than 2 months at room temperature. The Km for the silica-R52-mCh-mSOx-R5-6H was 16.5 ± 0.9 mM (compared with 16.5 ± 0.4 mM, 16.3 ± 0.3 mM, and 16.1 ± 0.4 mM for R52-mCh-mSOx-R5-6H, mSOx-R5-6H and mSOx-6H respectively in solution). The use of the "silica-enzymes" in sarcosine and peroxide assays was shown, and a design using particle sedimentation through the sample was examined. Using shadowgraphy and particle image velocimetry the particle trajectory through the sample was mapped and an hourglass design with a narrow waist shown to give good control of particle position. The hourglass biosensor was demonstrated for sarcosine assay in the clinically useful range of 2.5-10 μM in both a dynamic and end point measurement regime.
Collapse
Affiliation(s)
- Cassi J Henderson
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, Cambridge, CB3 0AS, UK; Department of Engineering, University of Cambridge, Charles Babbage Road, Cambridge, CB3 0FS, UK
| | - Elizabeth Pumford
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, Cambridge, CB3 0AS, UK
| | - Dushanth J Seevaratnam
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, Cambridge, CB3 0AS, UK
| | - Ronan Daly
- Department of Engineering, University of Cambridge, Charles Babbage Road, Cambridge, CB3 0FS, UK
| | - Elizabeth A H Hall
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, Cambridge, CB3 0AS, UK.
| |
Collapse
|
4
|
Xiong X, Tang Y, Zhao J, Zhao S. Oligonucleotide-stabilized fluorescent silver nanoclusters for the specific and sensitive detection of biotin. Analyst 2017; 141:1499-505. [PMID: 26750716 DOI: 10.1039/c5an02307f] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
A novel biotin fluorescent probe based on oligonucleotide-stabilized silver nanoclusters (DNA-AgNCs) was synthesized by employing a biotinylated cytosine-rich sequence as a synthesized template. The fluorescence properties of the DNA-AgNCs are related to the modified position of the DNA. When biotin is linked to the middle thymine base of the DNA sequence, the DNA-AgNCs emit the strongest fluorescence. Moreover, the stability of the DNA-AgNCs was affected by avidin through biotin-avidin binding, quenching the fluorescence of the DNA-AgNCs. In contrast, if free biotin is further introduced into this system, the quenching is apparently weakened by competition, leading to the restoration of fluorescence. This phenomenon can be utilized for the detection of biotin. Under the optimal conditions, the fluorescence recovery is linearly proportional to the concentration of biotin in the range of 10 nM-1.0 μM with a detection limit of 6.0 nM. This DNA-AgNCs probe with excellent fluorescent properties is sensitive and selective for the detection of biotin and has been applied for the determination of biotin in wheat flour.
Collapse
Affiliation(s)
- Xiaoli Xiong
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, 610068, China
| | - Yan Tang
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, 610068, China
| | - Jingjin Zhao
- Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources, Guangxi Normal University, Guilin, 541004, China.
| | - Shulin Zhao
- Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources, Guangxi Normal University, Guilin, 541004, China.
| |
Collapse
|
5
|
Structural Characterization of the Avidin Interactions with Fluorescent Pyrene-Conjugates: 1-Biotinylpyrene and 1-Desthiobiotinylpyrene. Molecules 2016; 21:molecules21101270. [PMID: 27689976 PMCID: PMC6274289 DOI: 10.3390/molecules21101270] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Revised: 09/07/2016] [Accepted: 09/17/2016] [Indexed: 11/28/2022] Open
Abstract
Avidin is a tetrameric protein that belongs to the calycin superfamily. It has been studied mainly because of its extraordinary affinity to biotin, which led to a wide range of applications based on the avidin-biotin system. In the present study, we report the first crystal structures of avidin in a complex with two novel fluorescent pyrene derivatives: 1-biotinylpyrene (B9P) and 1-desthiobiotinylpyrene (D9P). The crystal structures were solved by molecular replacement using the coordinates of avidin molecule as a starting model and the final models of avidin/B9P and avidin/D9P were refined to resolutions of 2.0 Å and 2.1 Å, respectively. Our data reveal changes in loop conformation as well as in overall fold and quaternary arrangement of the avidin upon the binding of these fluorescent probes. Moreover, the crystal structures allowed analysis of the details of the interactions between the protein and the pyrene derivatives. Structural description of the complexes will contribute to the design of conjugates for expanding the capabilities of avidin–biotin technology.
Collapse
|
6
|
Leary TF, Manafirasi S, Maldarelli C. Mass transfer in the biomolecular binding of a target against probe molecules on the surface of microbeads sequestered in wells in a microfluidic cell. LAB ON A CHIP 2015; 15:459-77. [PMID: 25408192 DOI: 10.1039/c4lc01185f] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Diagnostic tools which screen the binding interactions of a protein target against a display of biomolecular probes to identify molecules which bind the target are central to cell proteomic studies, and to diagnostic assays. Here, we study a microfluidic design for screening interactions in which the probe molecules are hosted on microbeads sequestered in wells arranged at the bottom of a microfluidic flow channel. Assays are undertaken by streaming an analyte solution with a fluorescently labelled target through the cell, and identifying the fluorescing beads. Numerical simulations are first constructed for the analyte flow over the microbeads in the well array, and the increase in the target concentration on the microbead surface. The binding profile is expressed as a function of the ratio of the convective to the diffusive transport rates (Peclet number or Pe), and the ratio of the kinetic to the diffusive rates (Damkohler number, Da). For any Pe, as Da becomes small enough, the transport is determined by the intrinsic kinetic binding rate. As Pe increases, a thin concentration boundary layer develops over the top surface of the microbead because of the convective flow, and target binds more rapidly. However, the relatively stagnant layers of liquid in the well provide a diffusion barrier which slows the target transport, and for any Da and Pe the transport is slower than equivalent patches of probes arranged on the channel wall. Experiments are also undertaken at high Pe, using the binding of fluorescently labelled NeutrAvidin as a target to probes of its binding partner, biotin, on the microbead surface. The binding profile is compared to the simulations to measure the kinetic rate constant, and this comparison shows that the transport in the cell is not kinetically limited because of the diffusion barriers created by the stagnant liquid layer in the well. Simulations and experiments on microbeads which are only partially recessed in the well demonstrate an increase in the mass transfer rate as more of the microbead surface intersects the flow and the diffusion limitation due to the stagnant layer of liquid surrounding the bottom part of the microbead is minimized.
Collapse
Affiliation(s)
- Thomas F Leary
- Levich Institute and Department of Chemical Engineering, The City College of the City University of New York, New York, New York 10031, USA.
| | | | | |
Collapse
|
7
|
Sun Q, Qian J, Tian H, Duan L, Zhang W. Rational design of biotinylated probes: fluorescent turn-on detection of (strept)avidin and bioimaging in cancer cells. Chem Commun (Camb) 2014; 50:8518-21. [DOI: 10.1039/c4cc03315a] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
8
|
HEO J. Spatial Distance Effect of Bienzymes on the Efficiency of Sequential Reactions in a Microfluidic Reactor Packed with Enzyme-immobilized Microbeads. ANAL SCI 2014; 30:991-7. [DOI: 10.2116/analsci.30.991] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Jinseok HEO
- Department of Chemistry, The State University of New York College at Buffalo
| |
Collapse
|
9
|
Chen X, Shojaei-Zadeh S, Gilchrist ML, Maldarelli C. A lipobead microarray assembled by particle entrapment in a microfluidic obstacle course and used for the display of cell membrane receptors. LAB ON A CHIP 2013; 13:3041-3060. [PMID: 23748734 DOI: 10.1039/c3lc50083g] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Platforms which can display cell membrane ligands and receptors as a microarray library of probes for screening against a target are essential tools in drug discovery, biomarker identification, and pathogen detection. Membrane receptors and ligands require their native bilayer environment to retain their selectivity and binding affinity, and this complicates displaying them in a microarray platform. In this study, a design is developed in which the probes are first incorporated in supported lipid bilayers formed around micron-sized particles (lipobeads), and the microbeads themselves are then arrayed on a surface by hydrodynamic capture in a microfluidic obstacle course of traps. The traps are "V" shaped open enclosures, which are arranged in a wide channel of a microfluidic device, and capture the lipobeads (slightly smaller than the channel height) as they are streamed through the course. Screening assays are undertaken directly in the device after assembly, by streaming a fluorescently labeled target through the device and detecting the bead fluorescence. Conditions are first established for which the supported bilayers on the bead surface remain intact during the capture and assay steps, using fluorescent tags in the bilayer to infer bilayer integrity. Numerical calculations of the hydrodynamic drag coefficient on the entrapped beads are presented in conjunction with the stability experiments to develop criteria for the bilayer stability as a function of the screening assay perfusion rate. Simulations of the flow streamlines are also presented to quantify the trapping efficiency of the obstacle course. Screening assays are illustrated, assaying fluorescently labeled NeutrAvidin with biotin, and labeled cholera toxin with its ganglioside binding ligand, GM1. Sequential capturing of sets of lipobeads (one at a time, and with each set bearing a different probe), followed by indexing the bead positions after each set is entrapped, allows for the construction of an indexed array of multiple probes without the need for particle encoding and is illustrated using the NeutrAvidin-biotin pair. Finally, the lipobead platform is used for quantitatively measuring the kinetic rate constants for the binding of a probe (biotin) to a target (NeutrAvidin).
Collapse
Affiliation(s)
- Xiaoxiao Chen
- Levich Institute and Department of Chemical Engineering, The City College of the City University of New York, New York, New York 10031, USA
| | | | | | | |
Collapse
|
10
|
Wang C, Jalikop SV, Hilgenfeldt S. Efficient manipulation of microparticles in bubble streaming flows. BIOMICROFLUIDICS 2012; 6:12801-1280111. [PMID: 22662069 PMCID: PMC3365321 DOI: 10.1063/1.3654949] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2011] [Accepted: 10/01/2011] [Indexed: 05/05/2023]
Abstract
Oscillating microbubbles of radius 20-100 μm driven by ultrasound initiate a steady streaming flow around the bubbles. In such flows, microparticles of even smaller sizes (radius 1-5 μm) exhibit size-dependent behaviors: particles of different sizes follow different characteristic trajectories despite density-matching. Adjusting the relative strengths of the streaming flow and a superimposed Poiseuille flow allows for a simple tuning of particle behavior, separating the trajectories of particles with a size resolution on the order of 1 μm. Selective trapping, accumulation, and release of particles can be achieved. We show here how to design bubble microfluidic devices that use these concepts to filter, enrich, and preconcentrate particles of selected sizes, either by concentrating them in discrete clusters (localized both stream- and spanwise) or by forcing them into narrow, continuous trajectory bundles of strong spanwise localization.
Collapse
Affiliation(s)
- Cheng Wang
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
| | | | | |
Collapse
|
11
|
Abstract
In flow cytometry, the quantitation of fluorophore-tagged ligands and receptors on cells or at particulate surfaces is achieved by the use of standard beads of known calibration. To the best of our knowledge, only those calibration beads based on fluorescein, EGFP, phycoerythyrin and allophycocyanine are readily available from commercial sources. Because fluorophore-based standards are specific to the selected fluorophore tag, their applicability is limited to the spectral region of resonance. Since quantum dots can be photo-excited over a continuous and broad spectral range governed by their size, it is possible to match the spectral range and width (absorbance and emission) of a wide range of fluorophores with appropriate quantum dots. Accordingly, quantitation of site coverage of the target fluorophores can be readily achieved using quantum dots whose emission spectra overlaps with the target fluorophore.This chapter focuses on the relevant spectroscopic concepts and molecular assembly of quantum dot fluorescence calibration beads. We first examine the measurement and applicability of spectroscopic parameters, ε, φ, and %T to fluorescence calibration standards, where ε is the absorption coefficient of the fluorophore, φ is the quantum yield of the fluorophore, and %T is the percent fraction of emitted light that is transmitted by the bandpass filter at the detector PMT. The modular construction of beads decorated with discrete quantities of quantum dots with defined spectroscopic parameters is presented in the context of a generalizable approach to calibrated measurements of fluorescence in flow cytometry.
Collapse
Affiliation(s)
- Tione Buranda
- Department of Pathology and Cancer Center, University of New Mexico School of Medicine, Albuquerque, NM, USA.
| | | | | |
Collapse
|
12
|
Chemburu S, Fenton K, Lopez GP, Zeineldin R. Biomimetic silica microspheres in biosensing. Molecules 2010; 15:1932-57. [PMID: 20336023 PMCID: PMC6257317 DOI: 10.3390/molecules15031932] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2010] [Revised: 03/16/2010] [Accepted: 03/17/2010] [Indexed: 11/16/2022] Open
Abstract
Lipid vesicles spontaneously fuse and assemble into a lipid bilayer on planar or spherical silica surfaces and other substrates. The supported lipid bilayers (SLBs) maintain characteristics of biological membranes, and are thus considered to be biomembrane mimetic systems that are stable because of the underlying substrate. Examples of their shared characteristics with biomembranes include lateral fluidity, barrier formation to ions and molecules, and their ability to incorporate membrane proteins into them. Biomimetic silica microspheres consisting of SLBs on solid or porous silica microspheres have been utilized for different biosensing applications. The advantages of such biomimetic microspheres for biosensing include their increased surface area to volume ratio which improves the detection limits of analytes, and their amenability for miniaturization, multiplexing and high throughput screening. This review presents examples and formats of using such biomimetic solid or porous silica microspheres in biosensing.
Collapse
Affiliation(s)
- Sireesha Chemburu
- Center for Biomedical Engineering, University of New Mexico, Albuquerque, NM 87131, USA
| | - Kyle Fenton
- Center for Biomedical Engineering, University of New Mexico, Albuquerque, NM 87131, USA
| | - Gabriel P. Lopez
- Center for Biomedical Engineering, University of New Mexico, Albuquerque, NM 87131, USA
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
- Department of Mechanical Engineering & Materials Science, Duke University, Durham, NC 27708, USA
| | - Reema Zeineldin
- Department of Pharmaceutical Sciences, Massachusetts College of Pharmacy and Health Sciences, 19 Foster Street, Worcester, MA 01608, USA
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +1-508-373-5762; Fax: +1- 508-890-5618
| |
Collapse
|
13
|
Bally M, Vörös J, Takeuchi S. Multilayers of hydrogels loaded with microparticles: a fast and simple approach for microarray manufacturing. LAB ON A CHIP 2010; 10:372-378. [PMID: 20091010 DOI: 10.1039/b916071j] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We present a novel and simple approach towards the creation of arrays of biomolecules for the multiplexed detection of biological interactions. Microarrays were obtained by cutting stacked layers of biofunctionalized polystyrene particle layers embedded in a permeable agarose matrix. Microparticles were therefore the vehicles for biorecognition. The three-dimensional constructs were obtained by consecutive dipping steps in a pre-gel solution. Our strategy enables the rapid manufacturing of a large number of array copies in a flexible manner and without any specialized instrumentation. Model binding assays for the detection of rabbit and mouse IgG were performed as a proof of concept using a fluorescence microscope for read-out. The limits of detection were in the low picomolar range for the sandwich assay while 1 IgG out of 50,000 background proteins could be detected in a reverse phase assay. Thus, without any assay optimization, sensitivities comparable to the ones usually observed for standard fluorescence-based assays were achieved with the particle/hydrogel array.
Collapse
Affiliation(s)
- Marta Bally
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH and University Zurich, 8092 Zurich, Switzerland
| | | | | |
Collapse
|
14
|
Thompson JA, Bau HH. Microfluidic, bead-based assay: Theory and experiments. J Chromatogr B Analyt Technol Biomed Life Sci 2010; 878:228-36. [PMID: 19766545 PMCID: PMC2818129 DOI: 10.1016/j.jchromb.2009.08.050] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2009] [Revised: 08/28/2009] [Accepted: 08/31/2009] [Indexed: 11/19/2022]
Abstract
Microbeads are frequently used as a solid support for biomolecules such as proteins and nucleic acids in heterogeneous microfluidic assays. However, relatively few studies investigate the binding kinetics on modified bead surfaces in a microfluidics context. In this study, a customized hot embossing technique is used to stamp microwells in a thin plastic substrate where streptavidin-coated agarose beads are selectively placed and subsequently immobilized within a conduit. Biotinylated quantum dots are used as a label to monitor target analyte binding to the bead's surface. Three-dimensional finite element simulations are carried out to model the binding kinetics on the bead's surface. The model accounts for surface exclusion effects resulting from a single quantum dot occluding multiple receptor sites. The theoretical predictions are compared and favorably agree with experimental observations. The theoretical simulations provide a useful tool to predict how varying parameters affect microbead reaction kinetics and sensor performance. This study enhances our understanding of bead-based microfluidic assays and provides a design tool for developers of point-of-care, lab-on-chip devices for medical diagnosis, food and water quality inspection, and environmental monitoring.
Collapse
Affiliation(s)
- Jason A. Thompson
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Haim H. Bau
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
15
|
McKenzie KG, Lafleur LK, Lutz BR, Yager P. Rapid protein depletion from complex samples using a bead-based microfluidic device for the point of care. LAB ON A CHIP 2009; 9:3543-8. [PMID: 20024034 DOI: 10.1039/b913806d] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Translation of sample preparation methods to point-of-care formats has remained a challenge. We present a plastic laminate microfluidic device for protein depletion from human plasma using ligand immobilized porous beads stored dry within a novel, pneumatically-driven mixer. The card design accelerated the protein depletion process from hours to minutes. Using immunoglobulin G as a model protein, we have successfully shown protein removal efficiency from spiked buffer between 70-80% and from diluted human plasma samples between 66-77%. Low non-specific binding of our downstream target ligand, immunoglobulin M, was observed with the spiked buffer and diluted human plasma samples. For future device optimization, the physical limitations to rapid protein removal on card were also explored. Bench-top experiments with improved mixing efficiency and a lower sample dilution factor achieved 99% IgG removal using the same amount of mixing time. This design can easily be adapted for depletion of other high abundance or interfering proteins by inclusion of other ligand immobilized beads.
Collapse
Affiliation(s)
- Katherine G McKenzie
- Department of Bioengineering, University of Washington, Box 355061, Foege N530J, Seattle, WA 98195-5061, USA.
| | | | | | | |
Collapse
|
16
|
Yun KS, Lee D, Kim HS, Yoon E. Microfluidic chips designed for measuring biomolecules through a microbead-based quantum dot fluorescence assay. Methods Mol Biol 2009; 544:53-67. [PMID: 19488693 DOI: 10.1007/978-1-59745-483-4_5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
This chapter introduces the demonstration of specific antibody detection by using a microbead-based assay with quantum dot (QD) fluorescence on a polydimethylsiloxane (PDMS) microfluidic chip. The microfluidic chip is designed to isolate a single microbead where the binding reaction of antibodies occurs on the surface. The microfluidic chip is fabricated on a glass substrate using a transparent silicone elastomer, PDMS, for easy access of monitoring and flexible gate operations to capture the single microbead. For antibody detection, a sequence of functionalized assays has been performed in the fabricated chip, including the capturing of microbeads, antibody injection into a microchamber, quantum dot injection, and fluorescence detection. Various concentrations of human IgG antibodies have been introduced to bind to a single microbead captured and isolated inside a designated microchamber in a small volume of 75 pL. Fluorescence detection is monitored using a CCD camera after the second binding with the QDs conjugated with anti-human IgG. In this experiment, a human IgG antibody concentration below 0.1 microg/mL has been successfully detected.
Collapse
Affiliation(s)
- Kwang-Seok Yun
- Department of Electronic Engineering, Sogang University, Seoul, Mapo-gu, Korea.
| | | | | | | |
Collapse
|
17
|
Biosensors based on release of compounds upon disruption of lipid bilayers supported on porous microspheres. Biointerphases 2008; 3:38. [DOI: 10.1116/1.2918743] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
18
|
Zeineldin R, Piyasena ME, Sklar LA, Whitten D, Lopez GP. Detection of membrane biointeractions based on fluorescence superquenching. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2008; 24:4125-4131. [PMID: 18302435 DOI: 10.1021/la703575r] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Assays for biointeractions of molecules with supported lipid bilayers using fluorescence superquenching are described. A conjugated cationic polymer was adsorbed on to silica microspheres, which were then coated with an anionic lipid bilayer. The lipid bilayer attenuated superquenching by acting as a barrier between the conjugated polymer and its quencher. Biointeractions of the lipid bilayer with a membrane lytic peptide, melittin, were detected and quantitated by superquenching of the conjugated polyelectrolyte in flow cytometric and microfluidic bioassays. A higher sensitivity for detecting melittin lysis of the lipid bilayer at lower concentrations and shorter times for melittin action was found using flow cytometry in this study in comparison to other existing methods. This study combined the sensitivity of superquenching and flow cytometry to detect biointeractions with a lipid bilayer, which serves as a platform for developing functional assays for sensor applications, lipid enzymology, and investigations of molecular interactions. In addition, this study demonstrated proof-of-concept for using superquenching detected as a result of lipid bilayer disruption in a microfluidic format.
Collapse
Affiliation(s)
- Reema Zeineldin
- Center for Biomedical Engineering, Department of Chemical & Nuclear Engineering, University of New Mexico, Albuquerque, NM 87131, USA
| | | | | | | | | |
Collapse
|
19
|
Basabe-Desmonts L, Benito-López F, Gardeniers HJGE, Duwel R, van den Berg A, Reinhoudt DN, Crego-Calama M. Fluorescent sensor array in a microfluidic chip. Anal Bioanal Chem 2007; 390:307-15. [PMID: 18034337 DOI: 10.1007/s00216-007-1720-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2007] [Revised: 10/09/2007] [Accepted: 10/23/2007] [Indexed: 01/09/2023]
Abstract
Miniaturization and automation are highly important issues for the development of high-throughput processes. The area of micro total analysis systems (muTAS) is growing rapidly and the design of new schemes which are suitable for miniaturized analytical devices is of great importance. In this paper we report the immobilization of self-assembled monolayers (SAMs) with metal ion sensing properties, on the walls of glass microchannels. The parallel combinatorial synthesis of sensing SAMs in individually addressable microchannels towards the generation of optical sensor arrays and sensing chips has been developed. [figure: see text] The advantages of microfluidic devices, surface chemistry, parallel synthesis, and combinatorial approaches have been merged to integrate a fluorescent chemical sensor array in a microfluidic chip. Specifically, five different fluorescent self-assembled monolayers have been created on the internal walls of glass microchannels confined in a microfluidic chip.
Collapse
Affiliation(s)
- Lourdes Basabe-Desmonts
- Department of Supramolecular Chemistry and Technology, MESA+ Institute for Nanotechnology, University of Twente, P.O. Box 217, 7500 AE, Enschede, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
20
|
Ferrance JP. Gellan beads as a transparent media for protein immobilization and affinity capture. J Chromatogr A 2007; 1165:86-92. [PMID: 17706234 DOI: 10.1016/j.chroma.2007.07.062] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2007] [Revised: 07/06/2007] [Accepted: 07/23/2007] [Indexed: 11/21/2022]
Abstract
Gellan gum beads are presented as a novel substrate for protein immobilization and immobilized protein activity measurements. The optical transparency of the gellan beads down to 200 nm provides a method for direct quantitation of the amount of protein immobilized onto the beads. The ability to utilize these beads in a non-aqueous activation step allowed for a fourfold increase in the amount of protein immobilized, and this method was used to immobilize Protein A onto gellan beads at a final yield of 1.42+/-0.07 mg of Protein A/g of beads. The optical transparency also allowed for detection of the activity of the immobilized Protein A simply by measuring the absorbance of the beads following capture of rabbit IgG. This activity measurement method was compared with a traditional method utilizing the amount of protein remaining in solution after the IgG capture step. The traditional method yielded an activity measurement of 10.9+/-0.2 mg IgG/mg of Protein A, while the absorbance method showed an activity of only 7.5+/-0.3 mg IgG/mg of Protein A. The difference can be explained by the more direct measurement used in the absorbance method. The optical transparency of the beads was also evaluated in a fluorescence based IgG capture experiment, showing that detection of fluorescent IgG captured on the beads was possible with no interference from the beads.
Collapse
Affiliation(s)
- Jerome P Ferrance
- Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22904, USA.
| |
Collapse
|
21
|
Abstract
During the process of self-association, reaching a thermodynamic equilibrium state in dilute solution is usually very fast, taking at most seconds for small organic (such as surfactants) solutions and hours for polymer solutions. It is very rare that days are necessary for soluble small organic molecules to reach thermodynamic stability in dilute solutions. This work reports such an unusually slow association of two polymerizable organic molecules, HOOC(CH2)3CCCC(CH2)3COOH and (EtO)3Si(CH2)3NH2, in their common solvent. The self-organization process of above complexes spanned several minutes to several days, depending on their concentrations. The morphologies of resultant aggregates, ranging from vesicles to solid spheres and to hollow spheres, were also tunable by varying the molar ratios of two precursors. Enriched functional COOH/NH2 groups on the aggregate surface can attach various antibodies, which endow the nanaoparticles with great potential applications as targeted drug-delivery vehicles. In addition, as-synthesized hybrid aggregates could be further stabilized by either addition reaction of diacetylenic acid or hydrolysis and condensation reactions of 3-aminopropyltriethoxysilane. In particular, the derived polydiacetylenic aggregates demonstrate a thermochromatic property and may be applied as sensing materials. Those novel phenomena, along with the simplicity in the preparation of aggregates, make the system promising in addressing related theoretical problems and practical applications.
Collapse
Affiliation(s)
- Huisheng Peng
- Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
| |
Collapse
|
22
|
Wu Y, Campos SK, Lopez GP, Ozbun MA, Sklar LA, Buranda T. The development of quantum dot calibration beads and quantitative multicolor bioassays in flow cytometry and microscopy. Anal Biochem 2007; 364:180-92. [PMID: 17397793 PMCID: PMC2018651 DOI: 10.1016/j.ab.2007.02.006] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2006] [Revised: 02/06/2007] [Accepted: 02/07/2007] [Indexed: 11/21/2022]
Abstract
The use of fluorescence calibration beads has been the hallmark of quantitative flow cytometry. It has enabled the direct comparison of interlaboratory data as well as quality control in clinical flow cytometry. In this article, we describe a simple method for producing color-generalizable calibration beads based on streptavidin functionalized quantum dots. Based on their broad absorption spectra and relatively narrow emission, which is tunable on the basis of dot size, quantum dot calibration beads can be made for any fluorophore that matches their emission color. In an earlier publication, we characterized the spectroscopic properties of commercial streptavidin functionalized dots (Invitrogen). Here we describe the molecular assembly of these dots on biotinylated beads. The law of mass action is used to readily define the site densities of the dots on the beads. The applicability of these beads is tested against the industry standard, namely commercial fluorescein calibration beads. The utility of the calibration beads is also extended to the characterization surface densities of dot-labeled epidermal growth factor ligands as well as quantitative indicators of the binding of dot-labeled virus particles to cells.
Collapse
Affiliation(s)
- Yang Wu
- Department of Pathology and Cancer Center, University of New Mexico, Albuquerque, NM 87131, USA
| | | | | | | | | | | |
Collapse
|
23
|
Basabe-Desmonts L, Reinhoudt DN, Crego-Calama M. Design of fluorescent materials for chemical sensing. Chem Soc Rev 2007; 36:993-1017. [PMID: 17534482 DOI: 10.1039/b609548h] [Citation(s) in RCA: 614] [Impact Index Per Article: 36.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
There is an enormous demand for chemical sensors for many areas and disciplines. High sensitivity and ease of operation are two main issues for sensor development. Fluorescence techniques can easily fulfill these requirements and therefore fluorescent-based sensors appear as one of the most promising candidates for chemical sensing. However, the development of sensors is not trivial; material science, molecular recognition and device implementation are some of the aspects that play a role in the design of sensors. The development of fluorescent sensing materials is increasingly captivating the attention of the scientists because its implementation as a truly sensory system is straightforward. This critical review shows the use of polymers, sol-gels, mesoporous materials, surfactant aggregates, quantum dots, and glass or gold surfaces, combined with different chemical approaches for the development of fluorescent sensing materials. Representative examples have been selected and they are commented here.
Collapse
Affiliation(s)
- Lourdes Basabe-Desmonts
- Department of Supramolecular Chemistry and Technology, MESA+ Institute for Nanotechnology, University of Twente, P. O. Box 217, 7500 AE Enschede, The Netherlands
| | | | | |
Collapse
|
24
|
Peoples MC, Phillips TM, Karnes HT. A capillary-based microfluidic instrument suitable for immunoaffinity chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2006; 848:200-7. [PMID: 17097929 DOI: 10.1016/j.jchromb.2006.10.032] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2006] [Revised: 10/10/2006] [Accepted: 10/16/2006] [Indexed: 11/15/2022]
Abstract
The analysis of biological samples to produce clinical or research data often requires measurement of analytes from complex biological matrices and limited volumes. Miniaturized analytical systems capable of minimal sample consumption and reduced analysis times have been employed to meet this need. The small footprint of this technology offers the potential for portability and patient point-of-care testing. A prototype microfluidic system has been developed and is presented for potential rapid assessment of clinical samples. The system has been designed for immunoaffinity chromatography as a means of separating analytes of interest from biological matrices. The instrument is capable of sub-microliter sample injection and detection of labeled antigens by long wavelength laser-induced fluorescence (LIF). The laboratory-constructed device is assembled from an array of components including two syringe pumps, a nano-gradient mixing chip, a micro-injector, a diode laser, and a separation capillary column made from a polymer/silica (PEEKsil) tube. An in-house program written with LabVIEW software controls the syringe pumps to perform step gradient elution and collects the LIF signal as a chromatogram. Initial columns were packed with silica beads to evaluate the system. Optimization of the device has been achieved by measuring flow accuracy with respect to column length and particle size. Syringe size and pressure effects have also been used to characterize the capability of the pumps. Based on test results, a 200-microm x 25-mm column packed with 1-microm silica beads was chosen for use with a 500-microL syringe. The system was tested for mixer proportioning by pumping different compositions of buffer and fluorescent dye solutions in a stepwise fashion. A linear response was achieved for increasing concentrations of fluorescent dye by online mixing (R2=0.9998). The effectiveness of an acidic gradient was confirmed by monitoring pH post-column and measuring premixed solutions offline. Finally, assessment of detectability was achieved by injecting fluorescent dye solutions and measuring the signal from the LIF detector. The limit of detection for the system with these solutions was 10.0 pM or 10.0 amol on-column. As proof-of-principle, immunoaffinity chromatography was demonstrated with immobilized rabbit anti-goat IgG and a fluorescent dye-goat IgG conjugate as a model antigen.
Collapse
Affiliation(s)
- Michael C Peoples
- Department of Pharmaceutics, Virginia Commonwealth University Medical Center, P.O. Box 980533, Richmond, VA 23298-0533, USA
| | | | | |
Collapse
|
25
|
Cao YC, Liu TC, Hua XF, Zhu XX, Wang HQ, Huang ZL, Zhao YD, Liu MX, Luo QM. Quantum dot optical encoded polystyrene beads for DNA detection. JOURNAL OF BIOMEDICAL OPTICS 2006; 11:054025. [PMID: 17092174 DOI: 10.1117/1.2358957] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
A novel multiplex analysis technology based on quantum dot (QD) optical encoded beads was studied. Carboxyl functionalized polystyrene beads, about 100 microm in size, were precisely encoded by the various ratios of two types of QDs whose emission wavelengths are 576 and 628 nm, respectively. Then the different encoded beads were covalently immobilized with different probes in the existing of sulfo-NHS and 1-[3-(Dimethylamino) propyl]-3-ethylcarbodiimide methiodide, and the probe density could reach to 3.1 mmol/g. These probe-linked encoded beads were used to detect the target DNA sequences in complex DNA solution by hybridization. Hybridization was visualized using fluorescein isothiocynate-labeled DNA sequences. The results show that the QDs and target signals can be obviously identified from a single-bead-level spectrum. This technology can detect DNA targets effectively with a detection limit of 0.2 microg/mL in complex solution.
Collapse
Affiliation(s)
- Yuan-Cheng Cao
- Key Laboratory of Biomedical Photonics of Ministry of Education, HuBei Bioinformatics and Molecular Imaging Key Laboratory, Huazhong University of Science and Technology, College of Life Science and Technology, Wuhan, HuBei, China 430074
| | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Huang TT, Mosier NS, Ladisch MR. Surface engineering of microchannel walls for protein separation and directed microfluidic flow. J Sep Sci 2006; 29:1733-42. [PMID: 16970182 DOI: 10.1002/jssc.200600150] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The preparation of surfaces in microfluidic devices that selectively retain proteins may be difficult to implement due to the incompatibility of derivatization methods with microdevice fabrication techniques. This review describes recently reported developments in simple and rapid methods for engineering the surface chemistries of microchannels based on construction of press-fit microdevices. These devices are fabricated by placing a glass fiber on a PDMS film and pressing the film on a silicon wafer or a microscope slide that has been derivatized with octadecyltrichlorosilane (ODS). The film adheres to the slide and forms an elliptically shaped channel around the fiber. The combination of surface wettability of a hydrophilic glass microfiber and the surrounding hydrophobic microchannel surfaces directs a narrow boundary layer of liquid next to the fiber in order to bring the sample in contact with the separation media and results in selective retention of proteins. This phenomenon may be exploited to enable microscale separation applications since there are a wide variety of fibers available with different chemistries. These may be used to rapidly fabricate microchannels that serve as stationary phases for separation at a microscale. The fundamental properties of such devices are discussed.
Collapse
Affiliation(s)
- Tom T Huang
- Laboratory of Renewable Resources Engineering, Purdue University, West Lafayette, IN, USA
| | | | | |
Collapse
|
27
|
Piyasena ME, Buranda T, Wu Y, Huang J, Sklar LA, Lopez GP. Near-simultaneous and real-time detection of multiple analytes in affinity microcolumns. Anal Chem 2006; 76:6266-73. [PMID: 15516117 DOI: 10.1021/ac049260f] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A miniaturized immunoassay system based on beads in poly(dimethylsiloxane) microchannels for analyzing multiple analytes has been developed. The method involves real-time detection of soluble molecules binding to receptor-bearing microspheres, sequestered in affinity column format inside a microfluidic channel. Identification and quantitation of analytes occurs via direct fluorescence measurements or fluorescence resonance energy transfer. A preliminary account of this work based on single-analyte format has been published in this journal (Buranda, T.; Huang, J.; Perez-Luna, V. H.; Schreyer, B.; Sklar, L. A.; Lopez, G. P. Anal. Chem. 2002, 74, 1149-1156). We have extended the work to a multianalyte model system composed of discrete segments of beads that bear distinct receptors. Near-simultaneous and real-time detection of diverse analytes is demonstrated. The importance of this work is established in the exploration of important factors related to the design, assessment, and utility of affinity microcolumn sensors. First, beads derivatized with surface chemistry suitable for the attachment of fluorescently labeled biomolecules of interest are prepared and characterized in terms of functionality and receptor site densities by flow cytometry. Second, calibrated beads are incorporated in microfluidic channels. The analytical device that emerges replicates the basic elements of affinity chromatography with the advantages of microscale and real-time direct measurement of bound analyte on beads rather than the indirect determination from eluted sample typical of affinity chromatography. In addition, the two-compartment analysis of the assay data as demonstrated in single-analyte columns provides a template upon which the dynamics of multiple-analyte assays can be characterized using existing theoretical models and be tested experimentally. The assay can potentially detect subfemtomole quantities of protein with high signal-to-noise ratio and a large dynamic range spanning nearly 4 orders of magnitude in analyte concentration in microliter to submicroliter volumes of analyte fluid. The approach has the potential to be generalized to a host of bioaffinity assay methods including analysis of protein complexes (e.g., biomolecular indicators of diseases). Proof-of-principle analytes include FLAG peptide and carcinoembryonic antigen detected at physiologically relevant concentration levels.
Collapse
Affiliation(s)
- Menake E Piyasena
- Cancer Center and Department of Pathology, University of New Mexico School of Medicine, Albuquerque, New Mexico 87131, USA
| | | | | | | | | | | |
Collapse
|
28
|
Fitzpatrick E, McBride S, Yavelow J, Najmi S, Zanzucchi P, Wieder R. Microfluidic Techniques for Single-Cell Protein Expression Analysis. Clin Chem 2006; 52:1080-8. [PMID: 16556686 DOI: 10.1373/clinchem.2005.059014] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
Background: The analysis of single cells obtained from needle aspirates of tumors is constrained by the need for processing. To this end, we investigated two microfluidic approaches to measure the expression of surface proteins in single cancer cells or in small populations (<50 cells).
Methods: One approach involved indirect fluorescence labeling of cell-surface proteins and channeling of cells in a microfluidic device past a fluorescence detector for signal quantification and analysis. A second approach channeled cells in a microfluidic device over detection zones coated with ligands to surface proteins and measured rates of passage and of retardation based on transient interactions between surface proteins and ligands.
Results: The fluorescence device detected expression of integrin α5 induced by basic fibroblast growth factor (FGF-2) treatment in MCF-7 cells and that of Her-2/neu in SK-BR-3 cells compared with controls. Experiments measuring passage retardation showed significant differences in passage rates between FGF-2–treated and untreated MCF-7 cells over reaction regions coated with fibronectin and antibody to integrin α5β1 compared with control regions. Blocking peptides reversed the retardation, demonstrating specificity.
Conclusions: Immunofluorescence detection in a microfluidic channel demonstrates the potential for assaying surface protein expression in a few individual cells and will permit the development of future iterations not requiring cell handling. The flow retardation device represents the first application of this technology for assessing cell-surface protein expression in cancer cells and may provide a way for analyzing expression profiles of single cells without preanalytical manipulation.
Collapse
Affiliation(s)
- Ethan Fitzpatrick
- Department of Biology, Rider University, Lawrenceville, NJ 07103, USA
| | | | | | | | | | | |
Collapse
|
29
|
Jin R, Cao YC, Thaxton CS, Mirkin CA. Glass-bead-based parallel detection of DNA using composite Raman labels. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2006; 2:375-80. [PMID: 17193054 DOI: 10.1002/smll.200500322] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Affiliation(s)
- Rongchao Jin
- Department of Chemistry and International Institute for Nanotechnology, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208, USA
| | | | | | | |
Collapse
|
30
|
Pumera M, Merkoçi A, Alegret S. New materials for electrochemical sensing VII. Microfluidic chip platforms. Trends Analyt Chem 2006. [DOI: 10.1016/j.trac.2005.08.005] [Citation(s) in RCA: 111] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
31
|
de Jong LAA, Uges DRA, Franke JP, Bischoff R. Receptor–ligand binding assays: Technologies and Applications. J Chromatogr B Analyt Technol Biomed Life Sci 2005; 829:1-25. [PMID: 16253574 DOI: 10.1016/j.jchromb.2005.10.002] [Citation(s) in RCA: 127] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2005] [Revised: 09/26/2005] [Accepted: 10/02/2005] [Indexed: 02/06/2023]
Abstract
Receptor-ligand interactions play a crucial role in biological systems and their measurement forms an important part of modern pharmaceutical development. Numerous assay formats are available that can be used to screen and quantify receptor ligands. In this review, we give an overview over both radioactive and non-radioactive assay technologies with emphasis on the latter. While radioreceptor assays are fast, easy to use and reproducible, their major disadvantage is that they are hazardous to human health, produce radioactive waste, require special laboratory conditions and are thus rather expensive on a large scale. This has led to the development of non-radioactive assays based on optical methods like fluorescence polarization, fluorescence resonance energy transfer or surface plasmon resonance. In light of their application in high-throughput screening environments, there has been an emphasis on so called "mix-and-measure" assays that do not require separation of bound from free ligand. The advent of recombinant production of receptors has contributed to the increased availability of specific assays and some aspects of the expression of recombinant receptors will be reviewed. Applications of receptor-ligand binding assays described in this review will relate to screening and the quantification of pharmaceuticals in biological matrices.
Collapse
Affiliation(s)
- Lutea A A de Jong
- Department of Analytical Biochemistry, University Centre for Pharmacy, A. Deusinglaan 1, 9713 AV Groningen, The Netherlands.
| | | | | | | |
Collapse
|
32
|
Bao N, Zhang Q, Xu JJ, Chen HY. Fabrication of poly(dimethylsiloxane) microfluidic system based on masters directly printed with an office laser printer. J Chromatogr A 2005; 1089:270-5. [PMID: 16130797 DOI: 10.1016/j.chroma.2005.07.001] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Applications of poly(dimethylsiloxane) (PDMS)-based microfluidic systems are more popular nowadays. Previous fabrication methods of the masters for PDMS microchannels require complicated steps and/or special device. In this paper, we demonstrated that the toner printed on the transparency film with the office laser printer (1200 dpi) can be used as the positive relief of the masters. The transparency film was printed in two steps in order to obtain the same printing quality for the crossed lines. With the laser-printed master, the depth of the fabricated PDMS microchannels was ca. 10 microm and the smallest width was ca. 60 microm. Surface characteristics of the PDMS/PDMS microchannels were performed with SEM. Their electrokinetic properties were investigated by the aids of the measurement of electroosmotic flow (EOF) and the Ohm's curve. Using the PDMS/PDMS microchip CE systems, electroactive biological molecules and non-electroactive inorganic ions were well separated, respectively. This simple approach could make it easy to carry out the studies of PDMS microfluidic systems in more general labs without special devices.
Collapse
Affiliation(s)
- Ning Bao
- The Key Lab of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093, PR China
| | | | | | | |
Collapse
|
33
|
Wu Y, Simons PC, Lopez GP, Sklar LA, Buranda T. Dynamics of fluorescence dequenching of ostrich-quenched fluorescein biotin: A multifunctional quantitative assay for biotin. Anal Biochem 2005; 342:221-8. [PMID: 15913533 DOI: 10.1016/j.ab.2005.03.046] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2005] [Revised: 03/02/2005] [Accepted: 03/28/2005] [Indexed: 11/23/2022]
Abstract
We describe a simple and rapid quantitative assay for biotin and biotin conjugates. The assay is based on the kinetic analysis of the enhancement of fluorescence of streptavidin/fluorescein biotin complexes in the presence of biotin. The kinetic response of fluorescence enhancement is proportional to the concentration of biotin. Standard calibration curves based on the kinetic response are obtained and detection limits of approximately 10(-9)M are established. Because the assay is amenable for use in small volumes of 5-50 microL or bead-based assays, the detection limits can be extended to the femtomole range. Since the assay depends on kinetic analysis, routine quantitation can be achieved without reference to standard curves. The dynamic aspects allow the assay to be extended to a broader range of applications including its use as an indicator of reagent mixing in laminar-flow assays carried out in microfluidic devices.
Collapse
Affiliation(s)
- Yang Wu
- Department of Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, NM 87131, USA
| | | | | | | | | |
Collapse
|
34
|
Chung WJ, Kim MS, Cho S, Park SS, Kim JH, Kim YK, Kim BG, Lee YS. Microaffinity purification of proteins based on photolytic elution: Toward an efficient microbead affinity chromatography on a chip. Electrophoresis 2005; 26:694-702. [PMID: 15690422 DOI: 10.1002/elps.200410005] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A bead affinity chromatography system, which was based on the photolytic elution method, was integrated into a glass-silicon microchip to purify specific target proteins. CutiCore beads, which were coupled with a photo-cleavable ligand, such as biotin and an RNA aptamer, were introduced into a filter chamber in the microchip. The protein mixture containing target protein labeled with fluorescein isothiocyanate (FITC) was then passed through the packed affinity beads in the microchamber by pressure-driven flow. During the process, the adsorbed protein on the bead was monitored by fluorescence. The concentrated target protein on the affinity bead was released by simple irradiation with UV light at a wavelength of 360 nm, and subsequently eluted with the phosphate buffer flow. The eluted target protein was quantitatively detected via the fluorescence intensity measurements at the downstream of the capillary connected to the outlet of the microchip. The microaffinity purification allowed for a successful method for the identification of specific target proteins from a protein mixture. In addition, the feasibility of this system for use as a diagnosis chip was demonstrated.
Collapse
Affiliation(s)
- Woo-Jae Chung
- School of Chemical Engineering, Seoul National University, Kwanak-Gu, Seoul, Korea
| | | | | | | | | | | | | | | |
Collapse
|
35
|
Li C, Lee KH. Affinity depletion of albumin from human cerebrospinal fluid using Cibacron-blue-3G-A-derivatized photopatterned copolymer in a microfluidic device. Anal Biochem 2004; 333:381-8. [PMID: 15450816 DOI: 10.1016/j.ab.2004.06.007] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2004] [Indexed: 10/26/2022]
Abstract
In the context of proteomic research, affinity separations for the prefractionation of complex mixtures, such as cell lysates or human tissues, have become increasingly important. Microfluidic devices have shown significant potential to achieve fast analysis and low sample consumption. Here, we demonstrate the use of a microfluidic device to achieve affinity capture of albumin from human cerebrospinal fluid. Traditional photolithography and wet etching techniques were used to fabricate devices from borosilicate glass wafers. Monolithic porous polymer was prepared in a microfluidic channel by photopolymerization of glycidyl methacrylate and trimethylolpropane trimethacrylate. After derivatization with Cibacron-blue-3G-A, the modified polymer was used to achieve affinity capture of lysozyme and human albumin. Both fluorescence detection and matrix-assisted laser desorption ionization time of flight mass spectrometry were used to validate the results.
Collapse
Affiliation(s)
- Chen Li
- School of Chemical and Biomolecular Engineering, Cornell University, Ithaca, NY 14853, USA
| | | |
Collapse
|
36
|
Wang Z, El-Ali J, Engelund M, Gotsaed T, Perch-Nielsen IR, Mogensen KB, Snakenborg D, Kutter JP, Wolff A. Measurements of scattered light on a microchip flow cytometer with integrated polymer based optical elements. LAB ON A CHIP 2004; 4:372-7. [PMID: 15269807 DOI: 10.1039/b400663a] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Flow cytometry is widely used for analyzing microparticles, such as cells and bacteria. In this paper, we report an innovative microsystem, in which several different optical elements (waveguides, lens and fiber-to-waveguide couplers) are integrated with microfluidic channels to form a complete microchip flow cytometer. All the optical elements, the microfluidic system, and the fiber-to-waveguide couplers were defined in one layer of polymer (SU-8, negative photoresist) by standard photolithography. With only a single mask procedure required, all the fabrication and packaging processes can be finished in one day. Polystyrene beads were measured in the microchip flow cytometer, and three signals (forward scattering, large angle scattering and extinction) were measured simultaneously for each bead. To our knowledge this is the first time forward scattered light and incident light extinction were measured in a microsystem using integrated optics. The microsystem can be applied for analyzing different kinds of particles and cells, and can easily be integrated with other microfluidic components.
Collapse
Affiliation(s)
- Z Wang
- MIC-Dept. of Micro and Nanotechnology, Technical University of Denmark, Building 345e, DK-2800 Kgs, Lyngby, Denmark.
| | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Malmstadt N, Hoffman AS, Stayton PS. "Smart" mobile affinity matrix for microfluidic immunoassays. LAB ON A CHIP 2004; 4:412-5. [PMID: 15269814 DOI: 10.1039/b315394k] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
There is a current need for simple methods for immobilizing biomolecules within microfluidic channels. Here, a technique is reported for reversibly immobilizing immunoassay components in a channel zone that can be simply controlled by integrated heating elements. Latex beads were modified with the temperature-responsive polymer poly(N-isopropylacrylamide)(PNIPAAm) and co-modified with biotinylated poly(ethylene glycol)(PEG). PNIPAAm undergoes a hydrophilic-to-hydrophobic transition when the temperature is raised above the lower critical solution temperature (LCST)( approximately 28 degrees C in the solutions used here). This reversible transition drives the aggregation and dis-aggregation of the modified beads in heated zones within poly(ethylene terephthalate)(PET) microchannels. Biotinylated monoclonal antibodies for the drug digoxin were bound via streptavidin to the biotin-PEG-coated beads. These antibody-functionalized beads were then reversibly immobilized by aggregation and hydrophobic adhesion to the surface of PET microfluidic channels in response to a thermal stimulus. The antibodies on the beads immobilized in the channel were shown to bind digoxin and a competitor fluorescent ligand from a flow stream in a quantitative competitive assay format that reported the digoxin concentration. The antibodies could be replenished for each immunoassay trial, using the reversible, temperature-controlled immobilization process. This technique allows reagent immobilization immediately prior to an analytical procedure, following the removal of previously utilized beads, guaranteeing fresh and active immobilized biomolecules. Furthermore, it provides a simple approach to multiplexing through the simultaneous or sequential injection of different antibody-coated bead species, potentially at multiple sites in the integrated device channels.
Collapse
Affiliation(s)
- Noah Malmstadt
- Department of Bioengineering, University of Washington, Seattle, WA 98195, USA
| | | | | |
Collapse
|
38
|
Vervoort N, Billen J, Gzil P, Baron GV, Desmet G. Importance and Reduction of the Sidewall-Induced Band-Broadening Effect in Pressure-Driven Microfabricated Columns. Anal Chem 2004; 76:4501-7. [PMID: 15283594 DOI: 10.1021/ac049930h] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The influence of the detailed design of the sidewall region upon the over-all band-broadening in microfabricated packed-bed or collocated monolithic support structure (COMOSS) columns has been investigated using computational fluid dynamics (CFD) simulation techniques. It is shown that, under unretained solute conditions, very small structural variations of the order of only 5% of the particle diameter can give rise to a 4-fold increase of the band-broadening. A comprehensive study has been made to quantify this effect as a function of the fluid velocity, the particle diameter, the channel widths, and of course, the sidewall region design. Because the sidewall effect can be fully attributed to a mismatch between the flow rates in the column center and in the sidewall region, it is fortunately also quite straightforward to avoid it. A very simple design, yielding band-broadening values identical to that of a hypothetical sidewall-less column for all possible values of the flow velocity, the particle diameter, or the channel width is proposed.
Collapse
Affiliation(s)
- Nico Vervoort
- Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, 1050 Brussels, Belgium.
| | | | | | | | | |
Collapse
|
39
|
Ali MF, Kirby R, Goodey AP, Rodriguez MD, Ellington AD, Neikirk DP, McDevitt JT. DNA hybridization and discrimination of single-nucleotide mismatches using chip-based microbead arrays. Anal Chem 2004; 75:4732-9. [PMID: 14674448 DOI: 10.1021/ac034106z] [Citation(s) in RCA: 117] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The development of a chip-based sensor array composed of individually addressable agarose microbeads has been demonstrated for the rapid detection of DNA oligonucleotides. Here, a "plug and play" approach allows for the simple incorporation of various biotinylated DNA capture probes into the bead-microreactors, which are derivatized in each case with avidin docking sites. The DNA capture probe containing microbeads are selectively arranged in micromachined cavities localized on silicon wafers. The microcavities possess trans-wafer openings, which allow for both fluid flow through the microreactors/analysis chambers and optical access to the chemically sensitive microbeads. Collectively, these features allow the identification and quantitation of target DNA analytes to occur in near real time using fluorescence changes that accompany binding of the target sample. The unique three-dimensional microenvironment within the agarose bead and the microfluidics capabilities of the chip structure afford a fully integrated package that fosters rapid analyses of solutions containing complex mixtures of DNA oligomers. These analyses can be completed at room temperature through the use of appropriate hybridization buffers. For applications requiring analysis of < or = 10(2) different DNA sequences, the hybridization times and point mutation selectivity factors exhibited by this bead array method exceed in many respects the operational characteristics of the commonly utilized planar DNA chip technologies. The power and utility of this microbead array DNA detection methodology is demonstrated here for the analysis of fluids containing a variety of similar 18-base oligonucleotides. Hybridization times on the order of minutes with point mutation selectivity factors greater than 10000 and limit of detection values of approximately 10(-13) M are obtained readily with this microbead array system.
Collapse
Affiliation(s)
- Mehnaaz F Ali
- Department of Chemistry & Biochemistry, Center for Nano- and Molecular Science and Technology, Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, USA
| | | | | | | | | | | | | |
Collapse
|
40
|
Huang TT, Geng T, Akin D, Chang WJ, Sturgis J, Bashir R, Bhunia AK, Robinson JP, Ladisch MR. Micro-assembly of functionalized particulate monolayer on C18-derivatized SiO2 surfaces. Biotechnol Bioeng 2003; 83:416-27. [PMID: 12800136 DOI: 10.1002/bit.10680] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This work describes a simple approach to immobilize functionalized colloidal microstructures onto a C(18)-coated SiO(2) substrate via specific or non-specific bio-mediated interactions. Biotinylated bovine serum albumin pre-adsorbed onto a C(18) surface was used to mediate the surface assembly of streptavidin-coated microbeads (2.8 microm), while a bare C(18) surface was used to immobilize anti-Listeria antibody-coated microbeads (2.8 microm) through hydrophobic interactions. For a C(18) surface pre-adsorbed with bovine serum albumin, hydrophobic polystyrene microbeads (0.8 microm) and positively charged dimethylamino microbeads (0.8 microm) were allowed to self-assemble onto the surface. A monolayer with high surface coverage was observed for both polystyrene and dimethylamino microbeads. The adsorption characteristics of Escherichia coli and Listeria monocytogenes on these microbead-based surfaces were studied using fluorescence microscopy. Both streptavidin microbeads pre-adsorbed with biotinylated anti-Listeria antibody and anti-Listeria antibody-coated microbeads showed specific capture of L. monocytogenes, while polystyrene and dimethylamino microbeads captured both E. coli and L. monocytogenes non-specifically. The preparation of microbead-based surfaces for the construction of microfluidic devices for separation, detection, or analysis of specific biological species is discussed.
Collapse
Affiliation(s)
- Tom T Huang
- School of Chemical Engineering and Laboratory of Renewable Resources Engineering, Purdue University, West Lafayette, Indiana 47907, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Affinity separations using microfabricated microfluidic devices:In situ photopolymerization and use in protein separations. BIOTECHNOL BIOPROC E 2003. [DOI: 10.1007/bf02942272] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
42
|
Malmstadt N, Yager P, Hoffman AS, Stayton PS. A smart microfluidic affinity chromatography matrix composed of poly(N-isopropylacrylamide)-coated beads. Anal Chem 2003; 75:2943-9. [PMID: 12964737 DOI: 10.1021/ac034274r] [Citation(s) in RCA: 113] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The efficient upstream processing of complex biological or environmental samples for subsequent biochemical analysis remains a challenge in many analytical systems. New microfluidic platforms that provide multidiagnostic capabilities on single chips face a similar challenge in getting specific analytes purified or contaminants removed in different fluid streams. Here, stimuli-responsive polymers have been used to construct "smart" beads that can be reversibly immobilized on microfluidic channel walls to capture and release targets. The 100-nm latex beads were surface-modified with the temperature-sensitive polymer poly(N-isopropylacrylamide) (PNIPAAm). At room temperature, a suspension of these beads flows through a microfluidic channel constructed of poly(ethylene terephthalate). However, when the temperature in the channel is raised above the lower critical solution temperature (LCST) of PNIPAAm, the beads aggregate and adhere to the walls of the channel. The adhered beads are stable for long durations on the channel walls (demonstrated up to 70 min) in the presence of flow. The beads were further modified with the affinity moiety biotin, which tightly binds streptavidin. The dual-modified beads were adhered to the channel walls and functioned as a chromatographic affinity separation matrix, capable of binding streptavidin that was flowed through the microfluidic channel. Upon the reverse thermal stimulation to below the PNIPAAm LCST, the beads and captured streptavidin were observed to quickly dissolve and elute from the channel walls. This temperature-responsive affinity chromatography matrix can thus be flowed into a column and aggregated via temperature change, followed by the controlled release of affinity-captured targets back into the microfluidic flow stream.
Collapse
Affiliation(s)
- Noah Malmstadt
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA
| | | | | | | |
Collapse
|
43
|
Vykoukal J, Vykoukal DM, Sharma S, Becker FF, Gascoyne PRC. Dielectrically Addressable Microspheres Engineered Using Self-Assembled Monolayers. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2003; 19:2425-2433. [PMID: 20686640 PMCID: PMC2913622 DOI: 10.1021/la0264318] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
We have used self-assembled monolayer techniques to produce a new class of microspheres with specifically engineered dielectric properties to enable their dielectrophoretic manipulation and identification in microsystems. Dielectrophoresis is an electrokinetic phenomenon that exploits frequency-dependent polarizability differences between a particle and its suspending medium to drive the movement of the particle toward or away from the high-field regions of an inhomogeneous electric field. While dielectrophoretic methods have been used extensively for cell manipulation, separation, and identification, we wished to extend the applicability of dielectrophoresis to molecular analysis by developing a panel of dielectric microspheres or "handles". Dielectric shell theory was used to model the dielectrophoretic response for a biomimetic particle composed of a thin insulating shell over a conductive interior. We specifically sought to modulate the specific capacitance, and thereby the dielectric properties, of the particle by controlling the thickness of the insulating layer. Such a structure was fabricated by covering a gold-coated polystyrene core particle with self-assembled monolayers of alkanethiol and phospholipid. To test the prediction that the carbon chain length of these layers should dictate the dielectric properties of the particles, we constructed a panel of six microsphere types with shell compositions ranging from a C(9) alkanethiol monolayer to a C(32) hybrid bilayer membrane. These microsphere populations were distinguishable and manipulatable by dielectrophoresis in a characteristic, frequency-dependent manner as predicted by theory. Experimentally derived specific membrane capacitance values were inversely related to the insulating shell thickness and agreed with published capacitance values for planar layers of similar thicknesses. These proof of principle studies are the first to demonstrate that the dielectric properties of particles can be specifically engineered to allow their dielectrophoretic manipulation and are a first step toward the development of bead-based dielectrophoretic microsystems for multiplexed molecular separation and analysis.
Collapse
Affiliation(s)
- Jody Vykoukal
- To whom correspondence should be addressed. E-mail: . Phone: 713-792-7607. Fax: 713-792-5940
| | | | | | | | | |
Collapse
|
44
|
Stevens PW, Wang CHJ, Kelso DM. Immobilized particle arrays: coalescence of planar- and suspension-array technologies. Anal Chem 2003; 75:1141-6. [PMID: 12641234 DOI: 10.1021/ac020580d] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Combining positive attributes of planar arrays and suspension arrays, immobilized particle arrays offer a new format in which immobilized submicrometer particles are arrayed on hydrogel-coated slides, providing 100+ assay replicates within each spot. This research describes how to prepare immobilized protein arrays and how to assay the binding of labeled target molecules to the arrayed capture probes. The assay system exhibits an intrinsic dynamic range of two to three decades, with coefficients of variation from 5 to 10%. For antibody-antigen binding, target capture appears to be reaction rate limited. For labeled antibody binding to antigen on the immobilized particles, the detection limit is approximately 0.5 ng/mL. When antibodies on the immobilized particles exhibit multivalent binding of target molecules, the detection limit is approximately 0.01 ng/mL. For protein arrays, potential advantages of this format are improved coating of the capture reagent, an increased number of options for protein presentation, reduced mass transport effects, and higher density multiplexing.
Collapse
Affiliation(s)
- Priscilla Wilkins Stevens
- Department of Biomedical Engineering, Robert R. McCormick School of Engineering and Applied Science, Northwestern University, 2145 Sheridan Road, Evanston, Illinois 60208-3107, USA
| | | | | |
Collapse
|
45
|
Auroux PA, Iossifidis D, Reyes DR, Manz A. Micro total analysis systems. 2. Analytical standard operations and applications. Anal Chem 2002; 74:2637-52. [PMID: 12090654 DOI: 10.1021/ac020239t] [Citation(s) in RCA: 815] [Impact Index Per Article: 37.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Pierre-Alain Auroux
- Department of Chemistry, Imperial College of Science, Technology and Medicine, London, UK
| | | | | | | |
Collapse
|