1
|
Wang YQ, Wang HC, Xiao ZJ, Bu LJ, Li J, Feng XC, Liang B, Liu WZ, Sun FY, Zhou SQ, Wang AJ. Machine learning strategy secures urban smart drinking water treatment plant through incremental advances. WATER RESEARCH 2025; 280:123541. [PMID: 40156974 DOI: 10.1016/j.watres.2025.123541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2024] [Revised: 03/14/2025] [Accepted: 03/21/2025] [Indexed: 04/01/2025]
Abstract
The integration of machine learning into urban drinking water treatment plants (DWTPs) offers a transformative pathway to ensure drinking water safety while promoting the development of smart, low-carbon cities. However, the effectiveness of these systems is frequently hindered by challenges related to data security and reliability, including imprecise control logic, sensor inconsistencies, and data transmission errors. In this study, we introduce a novel progressive Step-by-Step (SBS) machine learning strategy, initially applied to precise disinfectant dosage control in drinking water treatment and subsequently extended to enhance the data security of the entire water supply system. Among eight evaluated methods, the deep neural network integrated with the SBS strategy demonstrated superior performance. In a real-world DWTP, the SBS model significantly outperformed manual fuzzy control, reducing disinfectant dosage by 22.0 % and effluent turbidity by 16.0 %. Furthermore, through simulations of extreme data-missing scenarios and the application of SBS-based corrections, the robustness and security of DWTPs were maintained. The integration of the SBS strategy has the potential to significantly improve emergency management in urban water systems and elevate the intelligence of water supply networks. This approach not only strengthens urban resilience but also supports the safe and sustainable evolution of smart urban water systems.
Collapse
Affiliation(s)
- Yu-Qi Wang
- State Key Laboratory of Urban Water Resource and Environment, School of Eco-Environment, Harbin Institute of Technology Shenzhen, Shenzhen 518055, China
| | - Hong-Cheng Wang
- State Key Laboratory of Urban Water Resource and Environment, School of Eco-Environment, Harbin Institute of Technology Shenzhen, Shenzhen 518055, China.
| | - Zi-Jie Xiao
- Department of Chemical Engineering, KU Leuven, 3001 Leuven, Belgium
| | - Ling-Jun Bu
- Hunan Engineering Research Center of Water Security Technology and Application, College of Civil Engineering, Hunan University, Changsha 410082, China
| | - Jiuling Li
- Australian Centre for Water and Environmental Biotechnology, The University of Queensland, St. Lucia, Brisbane QLD 4072, Australia
| | - Xiao-Chi Feng
- State Key Laboratory of Urban Water Resource and Environment, School of Eco-Environment, Harbin Institute of Technology Shenzhen, Shenzhen 518055, China
| | - Bin Liang
- State Key Laboratory of Urban Water Resource and Environment, School of Eco-Environment, Harbin Institute of Technology Shenzhen, Shenzhen 518055, China
| | - Wen-Zong Liu
- State Key Laboratory of Urban Water Resource and Environment, School of Eco-Environment, Harbin Institute of Technology Shenzhen, Shenzhen 518055, China
| | - Fei-Yun Sun
- State Key Laboratory of Urban Water Resource and Environment, School of Eco-Environment, Harbin Institute of Technology Shenzhen, Shenzhen 518055, China
| | - Shi-Qing Zhou
- Department of Chemical Engineering, KU Leuven, 3001 Leuven, Belgium
| | - Ai-Jie Wang
- State Key Laboratory of Urban Water Resource and Environment, School of Eco-Environment, Harbin Institute of Technology Shenzhen, Shenzhen 518055, China
| |
Collapse
|
2
|
Morvan C, Nekoua MP, Mbani CJ, Debuysschere C, Alidjinou EK, Hober D. Enteroviruses in Water: Epidemiology, Detection and Inactivation. Environ Microbiol 2025; 27:e70109. [PMID: 40390239 PMCID: PMC12089693 DOI: 10.1111/1462-2920.70109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2025] [Revised: 04/03/2025] [Accepted: 05/06/2025] [Indexed: 05/21/2025]
Abstract
Enteroviruses are small non-enveloped RNA viruses commonly found in environmental water samples. Worldwide analysis of water provides evidence of the broad distribution of enteroviruses. In addition to their medical importance, they are used as markers of faecal contamination of water. This review focuses on water-borne human enteroviruses and their transmission. Methods for detecting enteroviruses in water are also presented as well as current strategies to control these enteric viruses in water.
Collapse
Affiliation(s)
- Corentin Morvan
- Laboratoire de Virologie ULR3610Université de Lille, CHU LilleLilleFrance
| | - Magloire P. Nekoua
- Laboratoire de Virologie ULR3610Université de Lille, CHU LilleLilleFrance
| | - Chaldam J. Mbani
- Laboratoire de Virologie ULR3610Université de Lille, CHU LilleLilleFrance
| | - Cyril Debuysschere
- Laboratoire de Virologie ULR3610Université de Lille, CHU LilleLilleFrance
| | | | - Didier Hober
- Laboratoire de Virologie ULR3610Université de Lille, CHU LilleLilleFrance
| |
Collapse
|
3
|
Wan D, Yu C, Zhao Y, Song G, Mi W, Zhu Y, Liu C, Bi Y. Photodegradation mechanism of organic contaminants mediated by chlorinated algal organic matter. WATER RESEARCH 2025; 281:123674. [PMID: 40280008 DOI: 10.1016/j.watres.2025.123674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2025] [Revised: 03/22/2025] [Accepted: 04/16/2025] [Indexed: 04/29/2025]
Abstract
Algal organic matter (AOM) significantly influences the photochemical behavior of dissolved organic matter in aquatic environments. This study investigated the effects of chlorination on the photophysical and photochemical properties of AOM derived from Microcystis aeruginosa, compared these alterations with those observed for natural organic matter (NOM), and examined their impact on the photodegradation of organic contaminants, with a particular focus on N,N‑diethyl-m-toluamide (DEET) as a model substrate. The results demonstrated that chlorination substantially altered the photochemical reactivity of AOM. AOM and NOM exhibit distinct reactivities, reflecting their varied molecular compositions and functional groups. Specifically, chlorination reduced the aromaticity (SUVA254 decreased by ∼42 %) and molecular weight (decreased by ∼30 %) of AOM, resulting in a shift of fluorescence peaks to lower wavelengths. It also enhanced the formation of singlet oxygen (1O2) and hydroxyl radical (•OH). Chlorinated extracellular organic matter (EOM) exhibited a remarkable increase in •OH quantum yield, with a 200-fold enhancement at a high free available chlorine (FAC) dose (FAC/TOC ratio of 2.0). The photodegradation of DEET, involved H-abstraction and hydroxylation by •OH, was significantly accelerated in chlorinated EOM, highlighting the critical role of chlorinated AOM in driving photosensitized degradation processes. The findings emphasized the role of chlorination in altering AOM's photochemical properties, with significant implications for the enhanced transformation of contaminants in natural and engineered aquatic systems.
Collapse
Affiliation(s)
- Dong Wan
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, PR China
| | - Chengjie Yu
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, PR China
| | - Yafei Zhao
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, PR China
| | - Gaofei Song
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, PR China
| | - Wujuan Mi
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, PR China
| | - Yuxuan Zhu
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, PR China
| | - Changzi Liu
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, PR China
| | - Yonghong Bi
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, PR China.
| |
Collapse
|
4
|
Jeon EB, Roy A, Park SY. Application of sodium hypochlorite for human norovirus and hepatitis A virus inactivation in groundwater. Appl Environ Microbiol 2024; 90:e0140524. [PMID: 39480096 PMCID: PMC11577748 DOI: 10.1128/aem.01405-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Accepted: 09/26/2024] [Indexed: 11/02/2024] Open
Abstract
In this study, the effect of sodium hypochlorite (10-200 ppm of Cl2) on the inactivation of human norovirus (HuNV) GII.4 and hepatitis A virus (HAV) in groundwater was investigated using propidium monoazide (PMA)/reverse transcription quantitative real-time PCR (RT-qPCR). Initially, 4.00 log10 genome copies/μL of HuNV GII.4 or 5.50 log10 genome copies/μL of HAV were artificially inoculated in groundwater. The titers of HuNV GII.4 and HAV decreased significantly (P < 0.05) with increasing Cl2 concentrations. Groundwater was treated with 10, 30, 50, 100, 150, and 200 ppm of Cl2, and the viable HuNV GII.4 was significantly (P < 0.05) reduced to 3.28 (0.21-log reduction), 3.18 (0.31-log reduction), 3.01 (0.48 log reduction), 2.75 (0.74 log reduction), 2.54 (0.95 log reduction), and 2.34 (1.15 log reduction) log10 genome copies/μL, respectively. The viable HAV was also significantly (P < 0.05) reduced to 4.99 (0.23 log reduction), 4.76 (0.46 log reduction), 4.55 (0.67 log reduction), 4.21 (1.01-log reduction), 3.89 (1.33 log reduction), and 3.64 (1.58 log reduction) log10 genome copies/μL, respectively. The decimal reduction times (D values) (1-log10 genome reduction) of HuNV GII.4 and HAV infectivity in groundwater were predicted as 116.7 and 98.9 ppm of Cl2, respectively, using the first-order kinetics model (HuNV GII.4: y = -0.0054x + 3.3585, correlation coefficient (R2) = 0.97; HAV: y = -0.0091x + 5.0470, R2 = 0.97). The result specifically suggests that 150- to 200-ppm Cl2 can potentially be used for the inactivation of >1-log10 genome copy/μL HuNV GII.4 and HAV in groundwater.IMPORTANCEGroundwater represents a vital component of the global water supply, serving as a crucial source of potable water for humans. It serves as a source of potable water for up to 50% of the global population and accounts for 43% of all water used for irrigation. It thus follows that the sustainable management of groundwater represents a pivotal solution. However, the regrowth of pathogens in water that is not treated with chlorine or where proper residual chlorine is not maintained represents a risk to public health.
Collapse
Affiliation(s)
- Eun Bi Jeon
- Department of Seafood Science and Technology, Institute of Marine Industry, Gyeongsang National University, Tongyeong, South Korea
| | - Anamika Roy
- Department of Seafood Science and Technology, Institute of Marine Industry, Gyeongsang National University, Tongyeong, South Korea
| | - Shin Young Park
- Department of Seafood Science and Technology, Institute of Marine Industry, Gyeongsang National University, Tongyeong, South Korea
| |
Collapse
|
5
|
Chaplin M, Leung K, Szczuka A, Hansen B, Rockey NC, Henderson JB, Wigginton KR. Linear Mixed Model of Virus Disinfection by Free Chlorine to Harmonize Data Collected across Broad Environmental Conditions. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:12260-12271. [PMID: 38923944 PMCID: PMC11238732 DOI: 10.1021/acs.est.4c02885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 05/30/2024] [Accepted: 05/31/2024] [Indexed: 06/28/2024]
Abstract
Despite the critical importance of virus disinfection by chlorine, our fundamental understanding of the relative susceptibility of different viruses to chlorine and robust quantitative relationships between virus disinfection rate constants and environmental parameters remains limited. We conducted a systematic review of virus inactivation by free chlorine and used the resulting data set to develop a linear mixed model that estimates chlorine inactivation rate constants for viruses based on experimental conditions. 570 data points were collected in our systematic review, representing 82 viruses over a broad range of environmental conditions. The harmonized inactivation rate constants under reference conditions (pH = 7.53, T = 20 °C, [Cl-] < 50 mM) spanned 5 orders of magnitude, ranging from 0.0196 to 1150 L mg-1 min-1, and uncovered important trends between viruses. Whereas common surrogate bacteriophage MS2 does not serve as a conservative chlorine disinfection surrogate for many human viruses, CVB5 was one of the most resistant viruses in the data set. The model quantifies the role of pH, temperature, and chloride levels across viruses, and an online tool allows users to estimate rate constants for viruses and conditions of interest. Results from the model identified potential shortcomings in current U.S. EPA drinking water disinfection requirements.
Collapse
Affiliation(s)
- Mira Chaplin
- Civil
and Environmental Engineering, University
of Michigan, 1351 Beal Ave., Ann Arbor, Michigan 48109-2138, United States
| | - Kaming Leung
- Civil
and Environmental Engineering, University
of Michigan, 1351 Beal Ave., Ann Arbor, Michigan 48109-2138, United States
| | - Aleksandra Szczuka
- Civil
and Environmental Engineering, University
of Michigan, 1351 Beal Ave., Ann Arbor, Michigan 48109-2138, United States
| | - Brianna Hansen
- Civil
and Environmental Engineering, University
of Michigan, 1351 Beal Ave., Ann Arbor, Michigan 48109-2138, United States
| | - Nicole C. Rockey
- Civil
and Environmental Engineering, Duke University, Durham, North Carolina, 27708, United States
| | - James B. Henderson
- Department
of Internal Medicine, University of Michigan
Medical School, NCRC Bldg. 16 #471C, 2800 Plymouth Rd., Ann
Arbor, Michigan 48109-2138, United States
| | - Krista R. Wigginton
- Civil
and Environmental Engineering, University
of Michigan, 1351 Beal Ave., Ann Arbor, Michigan 48109-2138, United States
| |
Collapse
|
6
|
Singh R, Ryu J, Park SS, Kim S, Kim K. Monitoring viruses and beta-lactam resistance genes through wastewater surveillance during a COVID-19 surge in Suwon, South Korea. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 922:171223. [PMID: 38417514 DOI: 10.1016/j.scitotenv.2024.171223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/20/2024] [Accepted: 02/21/2024] [Indexed: 03/01/2024]
Abstract
The present study reports data on a long-term campaign for monitoring SARS-CoV-2, norovirus, hepatitis A virus, and beta-lactam resistance genes in wastewater samples from a wastewater treatment plant during COVID-19 surge in Suwon, South Korea. Real-time digital PCR (RT-dPCR) assays indicated 100 % occurrence of all but hepatitis A virus and blaNDM gene in influent wastewater samples. CDC-N1 assay detected SARS-CoV-2 in all influent samples with an average log-transformed concentration of 5.1 ± 0.39 and the highest level at 6.02 gene copies/L. All samples were also positive for norovirus throughout the study with a mean concentration 5.67 ± 0.65 log10 gene copies/L. On the contrary, all treated wastewater (effluent) tested negative for both viruses' genetic materials. Furthermore, plasmid-mediated AmpC β-lactamases (PABLs) genes blaDHA, blaACC, and blaFOX, extended-spectrum β-lactamases (ESBLs) genes blaTEM and blaCTX, and Klebsiella pneumoniae carbapenemase (blaKPC) gene were measured at average concentrations of 7.05 ± 0.26, 5.60 ± 0.35, 7.82 ± 0.43, 8.38 ± 0.20, 7.64 ± 0.29, and 7.62 ± 0.41 log10 gene copies/L wastewater, respectively. Beta-lactam resistance genes showed strong correlations (r), the highest being 0.86 for blaKPC - blaFOX, followed by 0.82 for blaTEM - blaCTX and 0.79 for blaTEM - blaDHA. SARS-CoV-2 RNA occurrence in the wastewater was strongly associated (r = 0.796) with COVID-19 cases in the catchment during the initial study period of six months. A positive association of the SARS-CoV-2 RNA with the prevalence of COVID-19 cases showed a promising role of community-scale monitoring of pathogens to provide considerable early signals of infection dynamics. High concentrations of beta-lactam resistance genes in wastewater indicated a high concern for one of the biggest global health threats in South Korea and the need to find control measures. Moreover, antibiotic-resistance genes in treated wastewater flowing through water bodies and agricultural environments indicate further dissemination of antibiotic resistance traits and increasing microbial antibiotic resistance.
Collapse
Affiliation(s)
- Rajendra Singh
- Department of Biological and Environmental Science, Dongguk University, 32 Dongguk-ro, Ilsandong-gu, Goyang, Gyeonggi-do, South Korea
| | - Jaewon Ryu
- Department of Biological and Environmental Science, Dongguk University, 32 Dongguk-ro, Ilsandong-gu, Goyang, Gyeonggi-do, South Korea
| | - Sung Soo Park
- Department of Biological and Environmental Science, Dongguk University, 32 Dongguk-ro, Ilsandong-gu, Goyang, Gyeonggi-do, South Korea
| | - Sungpyo Kim
- Department of Environmental Systems Engineering, Korea University, 2511 Sejong-ro, Sejong City 30019, Republic of Korea
| | - Keugtae Kim
- Department of Biological and Environmental Science, Dongguk University, 32 Dongguk-ro, Ilsandong-gu, Goyang, Gyeonggi-do, South Korea.
| |
Collapse
|
7
|
Zhang M, Leong MW, Mitch WA, Blish CA, Boehm A. Persistence and free chlorine disinfection of human coronaviruses and their surrogates in water. Appl Environ Microbiol 2024; 90:e0005524. [PMID: 38511945 PMCID: PMC11022552 DOI: 10.1128/aem.00055-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Accepted: 02/28/2024] [Indexed: 03/22/2024] Open
Abstract
The coronavirus disease 2019 pandemic illustrates the importance of understanding the behavior and control of human pathogenic viruses in the environment. Exposure via water (drinking, bathing, and recreation) is a known route of transmission of viruses to humans, but the literature is relatively void of studies on the persistence of many viruses, especially coronaviruses, in water and their susceptibility to chlorine disinfection. To fill that knowledge gap, we evaluated the persistence and free chlorine disinfection of human coronavirus OC43 (HCoV-OC43) and its surrogates, murine hepatitis virus (MHV) and porcine transmissible gastroenteritis virus (TGEV), in drinking water and laboratory buffer using cell culture methods. The decay rate constants of human coronavirus and its surrogates in water varied, depending on virus and water matrix. In drinking water without disinfectant addition, MHV showed the largest decay rate constant (estimate ± standard error, 2.25 ± 0.09 day-1) followed by HCoV-OC43 (0.99 ± 0.12 day-1) and TGEV (0.65 ± 0.06 day-1), while in phosphate buffer without disinfectant addition, HCoV-OC43 (0.51 ± 0.10 day-1) had a larger decay rate constant than MHV (0.28 ± 0.03 day-1) and TGEV (0.24 ± 0.02 day-1). Upon free chlorine disinfection, the inactivation rates of coronaviruses were independent of free chlorine concentration and were not affected by water matrix, though they still varied between viruses. TGEV showed the highest susceptibility to free chlorine disinfection with the inactivation rate constant of 113.50 ± 7.50 mg-1 min-1 L, followed by MHV (81.33 ± 4.90 mg-1 min-1 L) and HCoV-OC43 (59.42 ± 4.41 mg-1 min-1 L). IMPORTANCE This study addresses an important knowledge gap on enveloped virus persistence and disinfection in water. Results have immediate practical applications for shaping evidence-based water policies, particularly in the development of disinfection strategies for pathogenic virus control.
Collapse
Affiliation(s)
- Mengyang Zhang
- Department of Civil and Environmental Engineering, School of Engineering and Doerr School of Sustainability, Stanford University, Stanford, California, USA
| | - Michelle Wei Leong
- Department of Medicine, Stanford University School of Medicine, Stanford, California, USA
| | - William A. Mitch
- Department of Civil and Environmental Engineering, School of Engineering and Doerr School of Sustainability, Stanford University, Stanford, California, USA
| | - Catherine A. Blish
- Department of Medicine, Stanford University School of Medicine, Stanford, California, USA
| | - Alexandria Boehm
- Department of Civil and Environmental Engineering, School of Engineering and Doerr School of Sustainability, Stanford University, Stanford, California, USA
| |
Collapse
|
8
|
Jiao M, Luo Y, Zhang F, Wang L, Chang J, Croué JP, Zhang T. Transformation of 6PPDQ during disinfection: Kinetics, products, and eco-toxicity assessment. WATER RESEARCH 2024; 250:121070. [PMID: 38159542 DOI: 10.1016/j.watres.2023.121070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 12/22/2023] [Accepted: 12/23/2023] [Indexed: 01/03/2024]
Abstract
N-phenyl-N'-(1,3-dimethyl butyl)-p-phenylenediamine-quinone (6PPDQ) currently arouses broad concerns because of its acute lethality to coho salmon and rainbow trout at environmentally relevant concentrations and the wide occurrence in runoff-impacted water. Investigation on the fate and transformation of 6PPDQ in various treatment processes is necessary for its risk assessment and control. Here, we explored the transformation of 6PPDQ during disinfection with its precursor 6PPD as a reference, focusing on kinetics, products, and toxicity variation. 6PPDQ readily reacted with hypochlorite and chlorine dioxide with second-order rate constants of 2580 ± 143 M-1 s-1 and 614 ± 52 M-1 s-1 (pH 7.0 and 25 °C), which are slightly lower than the reactions of 6PPD. We tentatively identified thirteen transformation products for 6PPDQ and eight for 6PPD in reaction with the two disinfectants. It seems that the quinone ring of 6PPDQ and the p-phenylenediamine moiety of 6PPD are reactive sites. The transformation of these compounds probably proceeds through Cl-substitution, ring cleavage, hydroxylation, and amine oxidation and hydrolysis. Tests with zebrafish embryos revealed that the transformation products of 6PPDQ could have higher eco-toxicity than the parent compound, while the toxicity of the 6PPD products remained nearly unchanged. The increased toxicity of 6PPDQ during disinfection highlights the necessity to substantially reduce its content before the disinfection of runoff-impacted water.
Collapse
Affiliation(s)
- Meng Jiao
- Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yiwen Luo
- Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Fan Zhang
- Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lihong Wang
- Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Jing Chang
- Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Jean-Philippe Croué
- Institut de Chimie des Milieux et des Matériaux IC2MP UMR 7285 CNRS, Université de Poitiers, France
| | - Tao Zhang
- Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
| |
Collapse
|
9
|
Wan D, Song G, Mi W, Tu X, Zhao Y, Bi Y. Insights into the Enhanced Photogeneration of Hydroxyl Radicals from Chlorinated Dissolved Organic Matter. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:805-815. [PMID: 38156625 DOI: 10.1021/acs.est.3c08257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
Free available chlorine has been and is being applied in global water treatment and readily reacts with dissolved organic matter (DOM) in aquatic environments, leading to the formation of chlorinated products. Chlorination enhances the photoreactivity of DOM, but the influence of chlorinated compounds on the photogeneration of hydroxyl radicals (•OH) has remained unexplored. In this study, a range of chlorinated carboxylate-substituted phenolic model compounds were employed to assess their •OH photogeneration capabilities. These compounds demonstrated a substantial capacity for •OH production, exhibiting quantum yields of 0.1-5.9 × 10-3 through direct photolysis under 305 nm and 0.2-9.5 × 10-3 through a triplet sensitizer (4-benzoylbenzoic acid)-inducing reaction under 365 nm LED irradiation. Moreover, the chlorinated compounds exhibited higher light absorption and •OH quantum yields compared to those of their unchlorinated counterparts. The •OH photogeneration capacity of these compounds exhibited a positive correlation with their triplet state one-electron oxidation potentials. Molecular-level compositional analysis revealed that aromatic structures rich in hydroxyl and carboxyl groups (e.g., O/C > 0.5 with H/C < 1.5) within DOM serve as crucial sources of •OH, and chlorination of these compounds significantly enhances their capacity to generate •OH upon irradiation. This study provides novel insights into the enhanced photogeneration of •OH from chlorinated DOM, which is helpful for understanding the fate of trace pollutants in chlorinated waters.
Collapse
Affiliation(s)
- Dong Wan
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, P. R. China
| | - Gaofei Song
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, P. R. China
| | - Wujuan Mi
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, P. R. China
| | - Xiaojie Tu
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, P. R. China
| | - Yafei Zhao
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, P. R. China
| | - Yonghong Bi
- Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan 430072, P. R. China
| |
Collapse
|
10
|
Foster AR, Haas CN, Gerba CP, Pepper IL. Effectiveness of monochloramine for inactivation of coronavirus in reclaimed water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 906:167634. [PMID: 37806580 DOI: 10.1016/j.scitotenv.2023.167634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 10/04/2023] [Accepted: 10/05/2023] [Indexed: 10/10/2023]
Abstract
Fecal shedding of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by infected persons into wastewater was documented early during the COVID-19 pandemic, thereby stimulating inquiries into the effectiveness of municipal wastewater treatment processes for the reduction of infectious viruses. In wastewater treatment plants, free chlorine has traditionally been the disinfectant utilized due to its low cost and high efficacy. However, regulations limiting disinfection by-products have prompted a shift to chloramination in many areas of the United States. While studies regarding the effectiveness of free chlorine against many viral agents are abundant, the efficacy of monochloramine (NH2Cl) has been less well researched. This study aimed to determine the effectiveness of pre-formed monochloramine for disinfection of human coronavirus 229E (HCoV-229E) in both phosphate-buffered saline (PBS) and reclaimed water from a water reclamation plant in Tucson, Arizona. Reclaimed water was sampled over the course of six months (August 2020 to November 2020), and dosed with monochloramine at 3 mg/L. An additional 1 mg/L free ammonia was added to simulate the operational conditions of the treatment plant. Viability was determined using MRC-5 host cell monolayers, using the TCID50 assay method. An average Ct99.9 (concentration of disinfectant multiplied by the contact time to achieve a 99.9 % reduction of the target organism) of 176 mg*min/L monochloramine was determined. No significant difference in inactivation rate was observed between the dosed reclaimed water and phosphate buffered saline (PBS). These data indicate that monochloramine is an effective disinfectant for coronaviruses. They also indicate that the water matrix type did not significantly impact the disinfection efficacy of monochloramine against HCoV-229E in reclaimed wastewater compared to PBS.
Collapse
Affiliation(s)
- Aidan R Foster
- Water & Energy Sustainable Technology (WEST) Center, University of Arizona, Tucson, AZ, USA.
| | - Charles N Haas
- Department of Civil, Architectural and Environmental Engineering, Drexel University, Philadelphia, PA, USA.
| | - Charles P Gerba
- Water & Energy Sustainable Technology (WEST) Center, University of Arizona, Tucson, AZ, USA.
| | - Ian L Pepper
- Water & Energy Sustainable Technology (WEST) Center, University of Arizona, Tucson, AZ, USA.
| |
Collapse
|
11
|
Torii S, David SC, Larivé O, Cariti F, Kohn T. Observed Kinetics of Enterovirus Inactivation by Free Chlorine Are Host Cell-Dependent. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:18483-18490. [PMID: 36649532 DOI: 10.1021/acs.est.2c07048] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Virucidal efficacies of disinfectants are typically assessed by infectivity assay utilizing a single type of host cell. Enteroviruses infect multiple host cells via various entry routes, and each entry route may be impaired differently by a given disinfectant. Yet, it is unknown how the choice of host cells affects the observed inactivation kinetics. Here, we evaluated the inactivation kinetics of echovirus 11 (E11) by free chlorine, ultraviolet (UV) irradiation, and heat, using three different host cells (BGMK, RD, and A549). Inactivation rates were independent of the host cell for treatment of E11 by UV or heat. Conversely, E11 inactivation by free chlorine occurred 2-fold faster when enumerated on BGMK cells compared with RD and A549 cells. Host cell-dependent inactivation kinetics by free chlorine were also observed for echovirus 7, 9, and 13, and coxsackievirus A9. E11 inactivation by free chlorine was partly caused by a loss in host cell attachment, which was most pronounced for BGMK cells. BGMK cells lack the attachment receptor CD55 and a key subunit of the uncoating receptor β2M, which may contribute to the differential inactivation kinetics for this cell type. Consequently, inactivation kinetics of enteroviruses should be assessed using host cells with different receptor profiles.
Collapse
Affiliation(s)
- Shotaro Torii
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015Lausanne, Switzerland
| | - Shannon Christa David
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015Lausanne, Switzerland
| | - Odile Larivé
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015Lausanne, Switzerland
| | - Federica Cariti
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015Lausanne, Switzerland
| | - Tamar Kohn
- Laboratory of Environmental Chemistry, School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), CH-1015Lausanne, Switzerland
| |
Collapse
|
12
|
Rashed AO, Huynh C, Merenda A, Rodriguez-Andres J, Kong L, Kondo T, Razal JM, Dumée LF. Dry-spun carbon nanotube ultrafiltration membranes tailored by anti-viral metal oxide coatings for human coronavirus 229E capture in water. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING 2023; 11:110176. [PMID: 37234558 PMCID: PMC10201849 DOI: 10.1016/j.jece.2023.110176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/21/2023] [Accepted: 05/20/2023] [Indexed: 05/28/2023]
Abstract
Although waterborne virus removal may be achieved using separation membrane technologies, such technologies remain largely inefficient at generating virus-free effluents due to the lack of anti-viral reactivity of conventional membrane materials required to deactivating viruses. Here, a stepwise approach towards simultaneous filtration and disinfection of Human Coronavirus 229E (HCoV-229E) in water effluents, is proposed by engineering dry-spun ultrafiltration carbon nanotube (CNT) membranes, coated with anti-viral SnO2 thin films via atomic layer deposition. The thickness and pore size of the engineered CNT membranes were fine-tuned by varying spinnable CNT sheets and their relative orientations on carbon nanofibre (CNF) porous supports to reach thicknesses less than 1 µm and pore size around 28 nm. The nanoscale SnO2 coatings were found to further reduce the pore size down to ∼21 nm and provide more functional groups on the membrane surface to capture the viruses via size exclusion and electrostatic attractions. The synthesized CNT and SnO2 coated CNT membranes were shown to attain a viral removal efficiency above 6.7 log10 against HCoV-229E virus with fast water permeance up to ∼4 × 103 and 3.5 × 103 L.m-2.h-1.bar-1, respectively. Such high performance was achieved by increasing the dry-spun CNT sheets up to 60 layers, orienting successive 30 CNT layers at 45°, and coating 40 nm SnO2 on the synthesized membranes. The current study provides an efficient scalable fabrication scheme to engineer flexible ultrafiltration CNT-based membranes for cost-effective filtration and inactivation of waterborne viruses to outperform the state-of-the-art ultrafiltration membranes.
Collapse
Affiliation(s)
- Ahmed O Rashed
- Deakin University, Geelong, Institute for Frontier Materials, 3216 Waurn Ponds, Victoria, Australia
| | - Chi Huynh
- LINTEC OF AMERICA, INC. Nano-Science and Technology Center, 2900 E. Plano Pkwy. Suite 100, Plano, TX 75074, United States
| | - Andrea Merenda
- School of Science, RMIT University, 124 La Trobe Street, Melbourne, VIC 3000, Australia
| | | | - Lingxue Kong
- Deakin University, Geelong, Institute for Frontier Materials, 3216 Waurn Ponds, Victoria, Australia
| | - Takeshi Kondo
- LINTEC OF AMERICA, INC. Nano-Science and Technology Center, 2900 E. Plano Pkwy. Suite 100, Plano, TX 75074, United States
| | - Joselito M Razal
- Deakin University, Geelong, Institute for Frontier Materials, 3216 Waurn Ponds, Victoria, Australia
| | - Ludovic F Dumée
- Khalifa University, Department of Chemical Engineering, Abu Dhabi, United Arab Emirates
- Research and Innovation Center on CO2 and Hydrogen, Khalifa University, Abu Dhabi, United Arab Emirates
- Center for Membrane and Advanced Water Technology, Khalifa University, Abu Dhabi, United Arab Emirates
| |
Collapse
|
13
|
Chen Z, Shi Q, Xu M, Yan H, Cao K, Mao Y, Wu Y, Hu HY. Quantitative models and potential surrogates for rapid evaluation and surveillance of chlorine disinfection efficacy in reclaimed water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 866:161372. [PMID: 36621502 DOI: 10.1016/j.scitotenv.2022.161372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 12/29/2022] [Accepted: 12/31/2022] [Indexed: 06/17/2023]
Abstract
Chlorine disinfection has become the most widely applied and indispensable technology in wastewater treatment and reuse to mitigate microbial risk and guarantee water safety. However, owing to complexities and high concentrations of contaminants in reclaimed water, rapid evaluation of chlorine disinfection efficacy is a crucial but challenging issue. Based on intensive experimental and statistical analyses, this study has established kinetic models and potential surrogates for rapid indication of the inactivation of microbial indicators and opportunistic pathogens during chlorine disinfection in different reclaimed waters. Overall, the constructed Selleck models performed very well to simulate log removal values (LRVs) of fecal coliforms, Pseudomonas aeruginosa and heterotrophic plate counts in all reclaimed water samples (R2 = 0.877-0.990). Moreover, total and Peak A fluorescence intensity as well as fluorescence integral intensities in Regions II and IV were found to have high response sensitivities during the chlorination process. Nevertheless, their effectiveness to act as potential surrogates of LRVs of microbial indicators needs to be further validated. The results from this study can provide valuable information on microbial safety surveillance of disinfection toward sustainable and long-term water reuse.
Collapse
Affiliation(s)
- Zhuo Chen
- State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou 510070, PR China; Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Qi Shi
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Meiying Xu
- State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou 510070, PR China
| | - Han Yan
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China.
| | - Kefan Cao
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Yu Mao
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Yinhu Wu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China.
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China; Research Institute for Environmental Innovation (Suzhou), Tsinghua, Jiangsu, Suzhou, 215163, PR China
| |
Collapse
|
14
|
Gandhi J, Prakash H. Photo-disinfection Processes for Bacterial Inactivation and Underlying Principles for Water Constituents’ Impact: A Review. CHEMICAL ENGINEERING JOURNAL ADVANCES 2023. [DOI: 10.1016/j.ceja.2023.100482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2023] Open
|
15
|
Forés E, Mejías-Molina C, Ramos A, Itarte M, Hundesa A, Rusiñol M, Martínez-Puchol S, Esteve-Bricullé P, Espejo-Valverde A, Sirés I, Calvo M, Araujo RM, Girones R. Evaluation of pathogen disinfection efficiency of electrochemical advanced oxidation to become a sustainable technology for water reuse. CHEMOSPHERE 2023; 313:137393. [PMID: 36442679 DOI: 10.1016/j.chemosphere.2022.137393] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 11/04/2022] [Accepted: 11/24/2022] [Indexed: 06/16/2023]
Abstract
Water treatment and reuse is gaining acceptance as a strategy to fight against water contamination and scarcity, but it usually requires complex treatments to ensure safety. Consequently, the electrochemical advanced processes have emerged as an effective alternative for water remediation. The main objective here is to perform a systematic study that quantifies the efficiency of a laboratory-scale electrochemical system to inactivate bacteria, bacterial spores, protozoa, bacteriophages and viruses in synthetic water, as well as in urban wastewater once treated in a wetland for reuse in irrigation. A Ti|RuO2-based plate and Si|BDD thin-film were comparatively employed as the anode, which was combined with a stainless-steel cathode in an undivided cell operating at 12 V. Despite the low resulting current density (<15 mA/cm2), both anodes demonstrated the production of oxidants in wetland effluent water. The disinfection efficiency was high for the bacteriophage MS2 (T99 in less than 7.1 min) and bacteria (T99 in about 30 min as maximum), but limited for CBV5 and TuV, spores and amoebas (T99 in more than 300 min). MS2 presented a rapid exponential inactivation regardless of the anode and bacteria showed similar sigmoidal curves, whereas human viruses, spores and amoebas resulted in linear profiles. Due the different sensitivity of microorganisms, different models must be considered to predict their inactivation kinetics. On this basis, it can be concluded that evaluating the viral inactivation from inactivation profiles determined for bacteria or some bacteriophages may be misleading. Therefore, neither bacteria nor bacteriophages are suitable models for the disinfection of water containing enteric viruses. The electrochemical treatment added as a final disinfection step enhances the inactivation of microorganisms, which could contribute to safe water reuse for irrigation. Considering the calculated low energy consumption, decentralized water treatment units powered by photovoltaic modules might be a near reality.
Collapse
Affiliation(s)
- Eva Forés
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Cristina Mejías-Molina
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Arantxa Ramos
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Marta Itarte
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Ayalkibet Hundesa
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Marta Rusiñol
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Sandra Martínez-Puchol
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Pau Esteve-Bricullé
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Alejandro Espejo-Valverde
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Ignasi Sirés
- Laboratori d'Electroquímica dels Materials i del Medi Ambient, Departament de Ciència de Materials i Química Física, Secció de Química Física, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1-11, 08028, Barcelona, Spain
| | - Miquel Calvo
- Secció d'Estadística, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain
| | - Rosa M Araujo
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Rosina Girones
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain.
| |
Collapse
|
16
|
Zhang Y, Huang K, Chen X, Wei M, Yu X, Su H, Gan P, Yu K. Inactivation of Ciliate Uronema Marinum under UV/Peroxydisulfate Advanced Disinfection System in Marine Water. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2022.122563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
17
|
Bi X, Liu D, Wang L, Huo Y, Fu ML, Sun W, Yuan B. Inactivation and genome damage of rotavirus and a human norovirus surrogate by monochloramine treatment and sequential application with UV. WATER RESEARCH 2022; 226:119309. [PMID: 36369682 DOI: 10.1016/j.watres.2022.119309] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 10/25/2022] [Accepted: 10/27/2022] [Indexed: 06/16/2023]
Abstract
The inactivation efficacy by monochloramine for disinfecting gastroenteritis-causing rotaviruses (RV) and Tulane viruses (TV), a surrogate for noroviruses, were evaluated in this study. In addition, the strategies for improving the disinfection efficiency of monochloramine by raising the temperature and sequentially implementing UV irradiation were investigated. The results showed that monochloramine was more effective in the inactivation of TV than RV. Additionally, the inactivation rate constants of RV and TV by monochloramine at 35 °C were improved approximately by 46% and 100%, respectively, compared to those at 25 °C. Moreover, applying UV irradiation before monochloramine enhanced the inactivation efficacy of RV and TV by 63% and 72% compared to monochloramine alone (UV: 6 mJ/cm2, NH2Cl: 60 ppm × min). Furthermore, the synergistic effect was observed during the RV inactivation by the sequential process. Especially, higher than 0.5 log10 reductions of RV VP1 genome contributed to the synergistic effect in sequential treatment, while less than 0.1 log10 reductions of RV VP1 genome were observed during UV alone (13 mJ/cm2) or monochloramine alone (94 ppm × min). The genome damage might be the primary mechanism of generating synergy in sequential treatment for the inactivation of RV. By comparison, no synergistic effect was discovered for the inactivation of TV due to high susceptibility to monochloramine and UV. The findings on the inactivation efficacy and mechanism for improvement will contribute to a wide application of monochloramine for virus inactivation in water treatment and distribution systems.
Collapse
Affiliation(s)
- Xiaochao Bi
- Xiamen Key Laboratory of Municipal and Industrial Solid Waste Utilization and Pollution Control, College of Civil Engineering, Huaqiao University, Xiamen, Fujian 361021, PR China
| | - Decai Liu
- Xiamen Key Laboratory of Municipal and Industrial Solid Waste Utilization and Pollution Control, College of Civil Engineering, Huaqiao University, Xiamen, Fujian 361021, PR China
| | - Lu Wang
- Xiamen Key Laboratory of Municipal and Industrial Solid Waste Utilization and Pollution Control, College of Civil Engineering, Huaqiao University, Xiamen, Fujian 361021, PR China
| | - Yang Huo
- Research Centre for Municipal Wastewater Treatment and Water Quality Protection, Northeast Normal University, Changchun 130117, China
| | - Ming-Lai Fu
- Xiamen Key Laboratory of Municipal and Industrial Solid Waste Utilization and Pollution Control, College of Civil Engineering, Huaqiao University, Xiamen, Fujian 361021, PR China.
| | - Wenjie Sun
- Department of Atmospheric and Hydrologic Science, St. Cloud State University, 720 4th Avenue South, St. Cloud, MN 56301, USA
| | - Baoling Yuan
- Xiamen Key Laboratory of Municipal and Industrial Solid Waste Utilization and Pollution Control, College of Civil Engineering, Huaqiao University, Xiamen, Fujian 361021, PR China; Key Laboratory of Songliao Aquatic Environment, Ministry of Education, Jilin Jianzhu University, Changchun 130118, PR China.
| |
Collapse
|
18
|
Deere D, Ryan U. Current assumptions for quantitative microbial risk assessment (QMRA) of Norovirus contamination of drinking water catchments due to recreational activities: an update. JOURNAL OF WATER AND HEALTH 2022; 20:1543-1557. [PMID: 36308498 DOI: 10.2166/wh.2022.114] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Contamination of drinking water from Norovirus (NoV) and other waterborne viruses is a major public health concern globally. Increasingly, quantitative microbial risk assessment (QMRA) is being used to assess the various risks from waterborne pathogens and evaluate control strategies. As urban populations grow and expand, there is increasing demand for recreational activities in drinking water catchments. QMRA relies on context-specific data to map out the pathways by which viruses can enter water and be transferred to drinking water consumers and identify risk factors and appropriate controls. This review examines the current evidence base and assumptions for QMRA analysis of NoV and other waterborne viral pathogens and recommends numerical values based on the most recent evidence to better understand the health risks associated with recreators in Australian drinking water sources; these are broadly applicable to all drinking water sources where recreational access is allowed. Key issues include the lack of an agreed upon data and dose-response models for human infectious NoV genotypes, faecal shedding by bathers, the extent of NoV infectivity and aggregation, resistance (secretor status) to NoV and the extent of secondary transmission.
Collapse
Affiliation(s)
- Dan Deere
- Water Futures and Water Research Australia, Sydney, Australia
| | - Una Ryan
- Harry Butler Institute, Murdoch University, Perth, Australia E-mail:
| |
Collapse
|
19
|
Lanrewaju AA, Enitan-Folami AM, Sabiu S, Swalaha FM. A review on disinfection methods for inactivation of waterborne viruses. Front Microbiol 2022; 13:991856. [PMID: 36212890 PMCID: PMC9539188 DOI: 10.3389/fmicb.2022.991856] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 08/29/2022] [Indexed: 11/13/2022] Open
Abstract
Water contamination is a global health problem, and the need for safe water is ever-growing due to the public health implications of unsafe water. Contaminated water could contain pathogenic bacteria, protozoa, and viruses that are implicated in several debilitating human diseases. The prevalence and survival of waterborne viruses differ from bacteria and other waterborne microorganisms. In addition, viruses are responsible for more severe waterborne diseases such as gastroenteritis, myocarditis, and encephalitis among others, hence the need for dedicated attention to viral inactivation. Disinfection is vital to water treatment because it removes pathogens, including viruses. The commonly used methods and techniques of disinfection for viral inactivation in water comprise physical disinfection such as membrane filtration, ultraviolet (UV) irradiation, and conventional chemical processes such as chlorine, monochloramine, chlorine dioxide, and ozone among others. However, the production of disinfection by-products (DBPs) that accompanies chemical methods of disinfection is an issue of great concern due to the increase in the risks of harm to humans, for example, the development of cancer of the bladder and adverse reproductive outcomes. Therefore, this review examines the conventional disinfection approaches alongside emerging disinfection technologies, such as photocatalytic disinfection, cavitation, and electrochemical disinfection. Moreover, the merits, limitations, and log reduction values (LRVs) of the different disinfection methods discussed were compared concerning virus removal efficiency. Future research needs to merge single disinfection techniques into one to achieve improved viral disinfection, and the development of medicinal plant-based materials as disinfectants due to their antimicrobial and safety benefits to avoid toxicity is also highlighted.
Collapse
Affiliation(s)
| | | | - Saheed Sabiu
- Department of Biotechnology and Food Science, Durban University of Technology, Durban, South Africa
| | - Feroz Mahomed Swalaha
- Department of Biotechnology and Food Science, Durban University of Technology, Durban, South Africa
| |
Collapse
|
20
|
Jenns K, Sassi HP, Zhou R, Cullen PJ, Carter D, Mai-Prochnow A. Inactivation of foodborne viruses: Opportunities for cold atmospheric plasma. Trends Food Sci Technol 2022. [DOI: 10.1016/j.tifs.2022.04.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
21
|
Tubatsi G, Kebaabetswe LP. Detection of Enteric Viruses from Wastewater and River Water in Botswana. FOOD AND ENVIRONMENTAL VIROLOGY 2022; 14:157-169. [PMID: 35150381 DOI: 10.1007/s12560-022-09513-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Accepted: 02/04/2022] [Indexed: 06/14/2023]
Abstract
Waterborne diseases remain a public health concern in developing countries where many lack access to safe water. Water testing mainly uses bacterial indicators to assess water quality, which may not fully indicate the threat from other non-bacterial pathogens like enteric viruses. This study was done to ascertain and establish the viral load, the temporal and spatial distribution of rotavirus A and norovirus (GI and GII) in sewage and river water samples. A total of 45 samples of raw and treated sewage, and surface water, were collected from a sludge activated wastewater treatment plant in Gaborone, and after treatment from the Notwane River, Botswana, over a period of 9 months (February 2016 to October 2016). Viruses were concentrated using polyethylene glycol/NaCl precipitation. Virus detection was performed using real-time polymerase chain reaction (RT-PCR). Rotavirus A was the most prevalent (84.4% positive samples), followed by Norovirus GI (48.9% positive samples), and Norovirus GII 46.7% positive samples). Detected viral loads went up to 104 genome copies per liter (copies/L) for all the viruses. The enteric viruses were detected in all the study sites with highest detection from site S1 (inlet). There was no significant association between physicochemical parameters and viral loads, except for pH which showed significant relationship with rotavirus and norovirus GII (p ≤ 0.05). This is the first study in Botswana to highlight the occurrence and quantification of the enteric viruses in treated and untreated wastewater, as well as surface water.
Collapse
Affiliation(s)
- Gosaitse Tubatsi
- Department of Biological Sciences and Biotechnology, Botswana International University of Science and Technology, P/Bag 16, Palapye, Botswana
| | - Lemme P Kebaabetswe
- Department of Biological Sciences and Biotechnology, Botswana International University of Science and Technology, P/Bag 16, Palapye, Botswana.
| |
Collapse
|
22
|
Xu X, Zuo J, Wan Q, Cao R, Xu H, Li K, Huang T, Wen G, Ma J. Effective inactivation of fungal spores by the combined UV/PAA: Synergistic effect and mechanisms. JOURNAL OF HAZARDOUS MATERIALS 2022; 430:128515. [PMID: 35739689 DOI: 10.1016/j.jhazmat.2022.128515] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Revised: 02/15/2022] [Accepted: 02/17/2022] [Indexed: 06/15/2023]
Abstract
Peracetic acid (PAA) can effectively inactivate fungi in water, while may pose a potential risk of regrowth after disinfection. The inactivation kinetic and mechanism of fungal spores by combined UV and PAA (UV/PAA) was investigated in this study. The results showed that synergistic factor of the inactivation of A. niger and A. flavus was 1.44 and 1.37, which indicated significant synergistic effect of UV/PAA. The k of A. niger and A. flavus was similar at pH 5.0 and 7.0, while decreased 60.00% and 39.13% at pH 9.0 compared with that at pH 7.0. The effect of HA concentration on the inactivation efficiency of fungal spores by UV/PAA was negative, while the effect of PAA concentration was positive. The membrane permeabilized cell of A. niger and A. flavus caused by UV/PAA was 17.0% and 31.7%, which was higher than that caused by PAA and UV alone. The changes of morphology of fungal spores and the leakage of intracellular material indicated that the damage of cell structure caused by UV/PAA system was more serious than that of UV or PAA alone. In addition, the four parts that contributed in UV/PAA system was in the following order: UV > radical > PAA > synergistic effect. The inactivation efficiency of combined UV and chlorine (UV/Cl2) was higher than that of UV/PAA. Furthermore, the typical order of the inactivation efficiency in different matrix was: phosphate buffer solution > surface water > secondary effluent. The regrowth potential of fungal spores after UV/PAA treatment was significantly lower than that by PAA alone, indicating that UV/PAA could decrease the microbial regrowth potential after PAA disinfection alone.
Collapse
Affiliation(s)
- Xiangqian Xu
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an 710055, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Jie Zuo
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an 710055, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Qiqi Wan
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an 710055, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Ruihua Cao
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an 710055, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Huining Xu
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an 710055, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Kai Li
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an 710055, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Tinglin Huang
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an 710055, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Gang Wen
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an 710055, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an 710055, China.
| | - Jun Ma
- School of Environment, Harbin Institute of Technology, China
| |
Collapse
|
23
|
Greaves J, Fischer RJ, Shaffer M, Bivins A, Holbrook MG, Munster VJ, Bibby K. Sodium hypochlorite disinfection of SARS-CoV-2 spiked in water and municipal wastewater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 807:150766. [PMID: 34627890 PMCID: PMC8497957 DOI: 10.1016/j.scitotenv.2021.150766] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 09/30/2021] [Accepted: 09/30/2021] [Indexed: 05/20/2023]
Abstract
Infectious severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has the potential to be collected in wastewater from mucus, sputum, and feces of infected individuals, raising questions about the appropriate handling and treatment of the resulting wastewater. Current evidence indicates the likelihood of waterborne SARS-CoV-2 transmission is low; nonetheless, confirming the efficacy of disinfection against SARS-CoV-2 is prudent to ensure multiple barriers of protection for infectious SARS-CoV-2 that could be present in municipal and hospital wastewater. Sodium hypochlorite (free chlorine) is widely used for pathogen control in water disinfection applications. In the current study, we investigated the inactivation of SARS-CoV-2 in DI water and municipal wastewater primary influent by sodium hypochlorite (free chlorine) addition. Our results showed rapid disinfection of SARS-CoV-2, with less than 1 mg-min/L required for >3 log10 TCID50 reduction in DI water. More than 5 mg-min/L was required for 3 log10 TCID50 reduction in primary influent, suggesting potential shielding of the virus by suspended solids. These results are consistent with expected virus inactivation by free chlorine and suggest the adequacy of free chlorine disinfection for inactivation of infectious SARS-CoV-2 in water matrices.
Collapse
Affiliation(s)
- Justin Greaves
- Department of Civil & Environmental Engineering & Earth Sciences, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Robert J Fischer
- Laboratory of Virology, Rocky Mountain Laboratories (RML), National Institutes of Health, Hamilton, MT 59840, USA
| | - Marlee Shaffer
- Department of Civil & Environmental Engineering & Earth Sciences, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Aaron Bivins
- Department of Civil & Environmental Engineering & Earth Sciences, University of Notre Dame, Notre Dame, IN 46556, USA
| | - Myndi G Holbrook
- Laboratory of Virology, Rocky Mountain Laboratories (RML), National Institutes of Health, Hamilton, MT 59840, USA
| | - Vincent J Munster
- Laboratory of Virology, Rocky Mountain Laboratories (RML), National Institutes of Health, Hamilton, MT 59840, USA
| | - Kyle Bibby
- Department of Civil & Environmental Engineering & Earth Sciences, University of Notre Dame, Notre Dame, IN 46556, USA.
| |
Collapse
|
24
|
Qiao Z, Ye Y, Szczuka A, Harrison KR, Dodd MC, Wigginton KR. Reactivity of Viral Nucleic Acids with Chlorine and the Impact of Virus Encapsidation. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:218-227. [PMID: 34905340 DOI: 10.1021/acs.est.1c04239] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Free chlorine disinfection is widely applied to inactivate viruses by reacting with their biomolecules, which include nucleic acids, proteins, and lipids. Knowing the reactivities of viral genomes with free chlorine and the protection that encapsidation provides would ultimately help predict virus susceptibility to the disinfectant. The relative reactivities of different viral genome types and the impact of viral higher order structure with free chlorine are poorly characterized. Here, we studied the reactivity of viral genomes representing four genome types from virus particles with diverse structures, namely, (+)ssRNA (MS2), dsRNA (φ6), ssDNA (φX174), and dsDNA (T3) with free chlorine. We compared the reactivities of these viral nucleic acids when they were suspended in phosphate buffer solutions (naked forms) and when they were in the native virus particles (encapsidated forms). The reactivities of nucleic acids were tracked by polymerase chain reaction (PCR)-based assays. The naked dsDNA of T3 was the least reactive with free chlorine, with an average second order rate constant normalized by the number of bases in the measured regions (in M-1 s-1 b-1) that was 34×, 65×, and 189× lower than those of the dsRNA of φ6, ssRNA of MS2, and ssDNA of φX174, respectively. Moreover, different regions in the ssRNA genome of MS2 and the dsRNA genome of φ6 exhibited statistically different reaction kinetics. The genomes within virus particles reacted slower than the naked genomes overall, but the extent of these differences varied among the four viruses. The results on viral nucleic acid reactivity help explain different susceptibilities of viruses to inactivation by free chlorine and also provide a valuable comparison of the susceptibilities of different nucleic acids to oxidants.
Collapse
Affiliation(s)
- Zhong Qiao
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Yinyin Ye
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Department of Civil, Structural, and Environmental Engineering, University at Buffalo, Buffalo, New York 14260, United States
| | - Aleksandra Szczuka
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Katherine R Harrison
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Michael C Dodd
- Department of Civil and Environmental Engineering, University of Washington, Seattle, Washington 98195, United States
| | - Krista R Wigginton
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
25
|
Chen C, Guo L, Yang Y, Oguma K, Hou LA. Comparative effectiveness of membrane technologies and disinfection methods for virus elimination in water: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 801:149678. [PMID: 34416607 PMCID: PMC8364419 DOI: 10.1016/j.scitotenv.2021.149678] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 07/20/2021] [Accepted: 08/11/2021] [Indexed: 05/22/2023]
Abstract
The pandemic of the 2019 novel coronavirus disease (COVID-19) has brought viruses into the public horizon. Since viruses can pose a threat to human health in a low concentration range, seeking efficient virus removal methods has been the research hotspots in the past few years. Herein, a total of 1060 research papers were collected from the Web of Science database to identify technological trends as well as the research status. Based on the analysis results, this review elaborates on the state-of-the-art of membrane filtration and disinfection technologies for the treatment of virus-containing wastewater and drinking water. The results evince that membrane and disinfection methods achieve a broad range of virus removal efficiency (0.5-7 log reduction values (LRVs) and 0.09-8 LRVs, respectively) that is attributable to the various interactions between membranes or disinfectants and viruses having different susceptibility in viral capsid protein and nucleic acid. Moreover, this review discusses the related challenges and potential of membrane and disinfection technologies for customized virus removal in order to prevent the dissemination of the waterborne diseases.
Collapse
Affiliation(s)
- Chao Chen
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
| | - Lihui Guo
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
| | - Yu Yang
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
| | - Kumiko Oguma
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| | - Li-An Hou
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, No.19, Xinjiekouwai Street, Haidian District, Beijing 100875, China; Xi'an High-Tech Institute, Xi'an 710025, China.
| |
Collapse
|
26
|
Iakovides IC, Manoli K, Karaolia P, Michael-Kordatou I, Manaia CM, Fatta-Kassinos D. Reduction of antibiotic resistance determinants in urban wastewater by ozone: Emphasis on the impact of wastewater matrix towards the inactivation kinetics, toxicity and bacterial regrowth. JOURNAL OF HAZARDOUS MATERIALS 2021; 420:126527. [PMID: 34329111 DOI: 10.1016/j.jhazmat.2021.126527] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 06/24/2021] [Accepted: 06/25/2021] [Indexed: 06/13/2023]
Abstract
This study investigated the impact of bench-scale ozonation on the inactivation of total cultivable and antibiotic-resistant bacteria (faecal coliforms, Escherichia coli, Pseudomonas aeruginosa, Enterococcus spp., and total heterotrophs), and the reduction of gene markers (16S rRNA and intl1) and antibiotic resistance genes (qacEΔ1, sul1, aadA1 and dfrA1) indigenously present in wastewater effluents treated by membrane bioreactor (MBR) or conventional activated sludge (CAS). The Chick-Watson model-predicted ozone exposure (CT) requirements, showed that higher CT values were needed for CAS- than MBR-treated effluents to achieve a 3-log reduction of each microbial group, i.e., ~30 and 10 gO3 min gDOC-1 respectively. Ozonation was efficient in inactivating the examined antibiotic-resistant bacteria, and no bacterial regrowth was observed after 72 h. The genes abundance decreased significantly by ozone, but an increase in their abundance was detected 72 h after storage of the treated samples. A very low removal of DOC was achieved and at the same time phyto- and eco-toxicity increased after the ozonation treatment in both wastewater matrices. The gene abundance, regrowth and toxicity results of this study may be of high environmental significance for comprehensive evaluation of ozone and may guide future studies in assessing these parameters for other oxidants/disinfectants.
Collapse
Affiliation(s)
- I C Iakovides
- Department of Civil and Environmental Engineering, School of Engineering, University of Cyprus, P.O. Box 20537, 1678 Nicosia, Cyprus; Nireas-International Water Research Centre, University of Cyprus, P.O. Box 20537, 1678 Nicosia, Cyprus
| | - K Manoli
- Department of Civil and Environmental Engineering, School of Engineering, University of Cyprus, P.O. Box 20537, 1678 Nicosia, Cyprus; Nireas-International Water Research Centre, University of Cyprus, P.O. Box 20537, 1678 Nicosia, Cyprus
| | - P Karaolia
- Nireas-International Water Research Centre, University of Cyprus, P.O. Box 20537, 1678 Nicosia, Cyprus
| | - I Michael-Kordatou
- Nireas-International Water Research Centre, University of Cyprus, P.O. Box 20537, 1678 Nicosia, Cyprus
| | - C M Manaia
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua de Diogo Botelho 1327, 4169-005 Porto, Portugal
| | - D Fatta-Kassinos
- Department of Civil and Environmental Engineering, School of Engineering, University of Cyprus, P.O. Box 20537, 1678 Nicosia, Cyprus; Nireas-International Water Research Centre, University of Cyprus, P.O. Box 20537, 1678 Nicosia, Cyprus.
| |
Collapse
|
27
|
Chen L, Deng Y, Dong S, Wang H, Li P, Zhang H, Chu W. The occurrence and control of waterborne viruses in drinking water treatment: A review. CHEMOSPHERE 2021; 281:130728. [PMID: 34010719 PMCID: PMC8084847 DOI: 10.1016/j.chemosphere.2021.130728] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 04/21/2021] [Accepted: 04/25/2021] [Indexed: 05/04/2023]
Abstract
As the coronavirus disease 2019 continues to spread globally, its culprit, the severe acute respiratory syndrome coronavirus 2 has been brought under scrutiny. In addition to inhalation transmission, the possible fecal-oral viral transmission via water/wastewater has also been brought under the spotlight, necessitating a timely global review on the current knowledge about waterborne viruses in drinking water treatment system - the very barrier that intercepts waterborne pathogens to terminal water users. In this article we reviewed the occurrence, concentration methods, and control strategies, also, treatment performance on waterborne viruses during drinking water treatment were summarized. Additionally, we emphasized the potential of applying the quantitative microbial risk assessment to guide drinking water treatment to mitigate the viral exposure risks, especially when the unregulated novel viral pathogens are of concern. This review paves road for better control of viruses at drinking water treatment plants to protect public health.
Collapse
Affiliation(s)
- Li Chen
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| | - Yang Deng
- Department of Earth and Environmental Studies, Montclair State University, Montclair, NJ, USA
| | - Shengkun Dong
- Key LLaboratory of Water Cycle and Water Security in Southern China of Guangdong Higher Education Institute, School of Civil Engineering, Sun Yat-sen University, Guangdong, China
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| | - Pan Li
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| | - Huaiyu Zhang
- Central and Southern China Institute of Municipal Engineering Design and Research, Hubei, China
| | - Wenhai Chu
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China.
| |
Collapse
|
28
|
Balachandran S, Charamba LVC, Manoli K, Karaolia P, Caucci S, Fatta-Kassinos D. Simultaneous inactivation of multidrug-resistant Escherichia coli and enterococci by peracetic acid in urban wastewater: Exposure-based kinetics and comparison with chlorine. WATER RESEARCH 2021; 202:117403. [PMID: 34274900 DOI: 10.1016/j.watres.2021.117403] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 06/23/2021] [Accepted: 06/29/2021] [Indexed: 06/13/2023]
Abstract
The presence of antibiotic resistance in wastewater sparked a great interest in investigating the inactivation of antibiotic-resistant bacteria by disinfecting agents. In this study, the inactivation kinetics of multidrug-resistant E. coli and enterococci by an emerging environmentally-friendly disinfectant, peracetic acid (PAA), in wastewater and phosphate buffer at pH 6.5 and pH 7.5, were characterized. It was demonstrated that the inactivation of the studied multidrug-resistant bacteria was governed by their exposure to PAA, i.e., integral of the PAA concentration over time (integral CT or ICT). Both regimes of the PAA inactivation of bacteria, i.e., initial resistance followed by a faster inactivation, were described well by an ICT-based Chick-Watson inactivation kinetic model. In wastewater at pH 7.5, the model-predicted ICT requirements showed that the multidrug-resistant enterococci were less susceptible to PAA than E. coli, e.g., to achieve a 3-log reduction, an ICT of 32.7 mg min/L and 23.4 mg min/L was needed, respectively. No regrowth of the studied bacteria was observed after 72 h from PAA disinfection at 25 ± 1 °C. Soluble constituents of wastewater decreased the PAA inactivation of both multidrug-resistant bacteria, i.e., higher inactivation was observed in phosphate buffer than wastewater at the same pH of 7.5. In phosphate buffer, a lower pH of 6.5 resulted in higher inactivation of multidrug-resistant E. coli compared with pH 7.5, but it did not affect the PAA inactivation of multidrug-resistant enterococci. A comparison with the most commonly used chemical disinfectant, chlorine, showed higher inactivation of both multidrug-resistant bacteria by chlorine and higher chlorine decay than PAA. The results of the present study may have implications in designing a PAA disinfection process, aiming at controlling antibiotic resistance, in terms of selecting a suitable fecal indicator and optimizing disinfectant dosing.
Collapse
Affiliation(s)
- Sanjana Balachandran
- Institute of Urban Water Management, Department of Hydrosciences, Technische Universität Dresden (TU Dresden), Zellescher Weg 18, 01069 Dresden, Germany
| | - Livia V C Charamba
- Institute of Urban Water Management, Department of Hydrosciences, Technische Universität Dresden (TU Dresden), Zellescher Weg 18, 01069 Dresden, Germany
| | - Kyriakos Manoli
- Nireas-International Water Research Center, University of Cyprus, P.O. Box 20537, CY-1678 Nicosia, Cyprus; Department of Civil and Environmental Engineering, University of Cyprus, P.O. Box 20537, CY-1678 Nicosia, Cyprus.
| | - Popi Karaolia
- Nireas-International Water Research Center, University of Cyprus, P.O. Box 20537, CY-1678 Nicosia, Cyprus
| | - Serena Caucci
- Institute for Integrated Management of Material Fluxes and of Resources (UNU-FLORES), United Nations University, Ammonstrasse 74, 01067 Dresden, Germany
| | - Despo Fatta-Kassinos
- Nireas-International Water Research Center, University of Cyprus, P.O. Box 20537, CY-1678 Nicosia, Cyprus; Department of Civil and Environmental Engineering, University of Cyprus, P.O. Box 20537, CY-1678 Nicosia, Cyprus.
| |
Collapse
|
29
|
Kerviel A, Zhang M, Altan-Bonnet N. A New Infectious Unit: Extracellular Vesicles Carrying Virus Populations. Annu Rev Cell Dev Biol 2021; 37:171-197. [PMID: 34270326 DOI: 10.1146/annurev-cellbio-040621-032416] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Viral egress and transmission have long been described to take place through single free virus particles. However, viruses can also shed into the environment and transmit as populations clustered inside extracellular vesicles (EVs), a process we had first called vesicle-mediated en bloc transmission. These membrane-cloaked virus clusters can originate from a variety of cellular organelles including autophagosomes, plasma membrane, and multivesicular bodies. Their viral cargo can be multiples of nonenveloped or enveloped virus particles or even naked infectious genomes, but egress is always nonlytic, with the cell remaining intact. Here we put forth the thesis that EV-cloaked viral clusters are a distinct form of infectious unit as compared to free single viruses (nonenveloped or enveloped) or even free virus aggregates. We discuss how efficient and prevalent these infectious EVs are in the context of virus-associated diseases and highlight the importance of their proper detection and disinfection for public health. Expected final online publication date for the Annual Review of Cell and Developmental Biology, Volume 37 is October 2021. Please see http://www.annualreviews.org/page/journal/pubdates for revised estimates.
Collapse
Affiliation(s)
- Adeline Kerviel
- Laboratory of Host-Pathogen Dynamics, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892, USA;
| | - Mengyang Zhang
- Laboratory of Host-Pathogen Dynamics, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892, USA; .,Department of Civil and Environmental Engineering, The George Washington University, Washington, DC 20052, USA
| | - Nihal Altan-Bonnet
- Laboratory of Host-Pathogen Dynamics, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892, USA;
| |
Collapse
|
30
|
Wan D, Wang H, Sharma VK, Selvinsimpson S, Dai H, Luo F, Wang C, Chen Y. Mechanistic Investigation of Enhanced Photoreactivity of Dissolved Organic Matter after Chlorination. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:8937-8946. [PMID: 34165279 DOI: 10.1021/acs.est.1c02704] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Chlorine is commonly used in disinfection processes in wastewater treatment plants prior to discharge of the effluents into receiving waters. Effluent organic matter and humic substances constitute up to 90% of dissolved organic matter (DOM) in receiving water, which induces photogeneration of reactive species (RS) such as excited triplet state of DOM (3DOM*), singlet oxygen (1O2), and hydroxyl radical (•OH). The RS plays an important role in the attenuation of trace pollutants. However, the effect of chlorine disinfection on the photoreactivity of the DOM has remained unclear. Here, we investigated the physicochemical properties and subsequent RS variation after chlorination of DOM. Solid-state 13C cross-polarization/magic angle-spinning NMR and Fourier transform ion cyclotron resonance mass spectrometry verified that the aromaticity, electron-donating capacity (EDC), and average molecular weight of DOM decreased markedly after chlorination. It was found for the first time that the photoproduction of 3DOM*, 1O2, and •OH increased markedly after chlorination of DOM upon irradiation of simulated sunlight. The quantum yields of 3DOM*, 1O2, and •OH were positively correlated with E2/E3 (ratio of the absorbance at 254 to 365 nm) while negatively correlated with EDC before and after chlorination. These findings highlight the synergetic effect of chlorine disinfection on the photosensitization of DOM under irradiation of sunlight, which will promote the removal of trace pollutants in surface waters.
Collapse
Affiliation(s)
- Dong Wan
- School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, P. R. China
| | - Haiyue Wang
- School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, P. R. China
| | - Virender K Sharma
- Department of Environmental and Occupational Health, School of Public Health, Texas A&M University, College Station, Texas 77843, United States
| | | | - Hongliang Dai
- School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, P. R. China
| | - Fan Luo
- School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, P. R. China
| | - Chengjun Wang
- College of Resources and Environmental Science, South-Central University for Nationalities, Wuhan 430074, P. R. China
| | - Yong Chen
- School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, P. R. China
| |
Collapse
|
31
|
Bandala ER, Kruger BR, Cesarino I, Leao AL, Wijesiri B, Goonetilleke A. Impacts of COVID-19 pandemic on the wastewater pathway into surface water: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 774:145586. [PMID: 33607440 PMCID: PMC7862925 DOI: 10.1016/j.scitotenv.2021.145586] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 01/27/2021] [Accepted: 01/28/2021] [Indexed: 05/16/2023]
Abstract
With global number of cases 106 million and death toll surpassing 2.3 million as of mid-February 2021, the COVID-19 pandemic is certainly one of the major threats that humankind have faced in modern history. As the scientific community navigates through the overwhelming avalanche of information on the multiple health impacts caused by the pandemic, new reports start to emerge on significant ancillary effects associated with the treatment of the virus. Besides the evident health impacts, other emerging impacts related to the COVID-19 pandemic, such as water-related impacts, merits in-depth investigation. This includes strategies for the identification of these impacts and technologies to mitigate them, and to prevent further impacts not only in water ecosystems, but also in relation to human health. This paper has critically reviewed currently available knowledge on the most significant potential impacts of the COVID-19 pandemic on the wastewater pathway into surface water, as well as technologies that may serve to counteract the major threats posed, key perspectives and challenges. Additionally, current knowledge gaps and potential directions for further research and development are identified. While the COVID-19 pandemic is an ongoing and rapidly evolving situation, compiling current knowledge of potential links between wastewater and surface water pathways as related to environmental impacts and relevant associated technologies, as presented in this review, is a critical step to guide future research in this area.
Collapse
Affiliation(s)
- Erick R Bandala
- Division of Hydrologic Sciences, Desert Research Institute, 755 E. Flamingo Road, Las Vegas, NV 89119, USA.
| | - Brittany R Kruger
- Division of Hydrologic Sciences, Desert Research Institute, 755 E. Flamingo Road, Las Vegas, NV 89119, USA
| | - Ivana Cesarino
- São Paulo State University (UNESP), School of Agriculture, Botucatu, Brazil
| | - Alcides L Leao
- São Paulo State University (UNESP), School of Agriculture, Botucatu, Brazil
| | - Buddhi Wijesiri
- Faculty of Engineering, Queensland University of Technology (QUT), Brisbane, Australia
| | - Ashantha Goonetilleke
- Faculty of Engineering, Queensland University of Technology (QUT), Brisbane, Australia
| |
Collapse
|
32
|
Zhang M, Ghosh S, Kumar M, Santiana M, Bleck CKE, Chaimongkol N, Altan-Bonnet N, Shuai D. Emerging Pathogenic Unit of Vesicle-Cloaked Murine Norovirus Clusters is Resistant to Environmental Stresses and UV 254 Disinfection. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:6197-6205. [PMID: 33856208 DOI: 10.1021/acs.est.1c01763] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
An individual virion was long believed to act as an independent infectious unit in virology, until the recent discovery of vesicle-cloaked virus clusters which has greatly challenged this central paradigm. Vesicle-cloaked virus clusters (also known as viral vesicles) are phospholipid-bilayer encapsulated fluid sacs that contain multiple virions or multiple copies of viral genomes. Norovirus is a global leading causative agent of gastroenteritis, and the reported prevalence of vesicle-cloaked norovirus clusters in stool has raised concerns whether the current disinfection, sanitation, and hygiene practices can effectively control environmental pollution by these pathogenic units. In this study, we have demonstrated that vesicle-cloaked murine norovirus (MNV-1) clusters were highly persistent under temperature variation (i.e., freeze-thaw) and they were partially resistant to detergent decomposition. MNV-1 vesicles were 1.89-3.17-fold more infectious in vitro than their free virus counterparts. Most importantly, MNV-1 vesicles were up to 2.16-times more resistant to UV254 disinfection than free MNV-1 at a low viral load in vitro. Interestingly, with the increase of the viral load, free MNV-1 and MNV-1 vesicles showed equivalent resistance to UV254 disinfection. We show that the increased multiplicity of infection provided by vesicles is in part responsible for these attributes. Our study, for the first time, sheds light on the environmental behavior of vesicle-cloaked virus clusters as unique emerging pathogenic units. Our study highlights the need to revisit current paradigms of disinfection, sanitation, and hygiene practices for protecting public health.
Collapse
Affiliation(s)
- Mengyang Zhang
- Department of Civil and Environmental Engineering, The George Washington University, Washington, District of Columbia 20052, United States
- Laboratory of Host-Pathogen Dynamics, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892, United States
| | - Sourish Ghosh
- Laboratory of Host-Pathogen Dynamics, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892, United States
| | - Manish Kumar
- Laboratory of Host-Pathogen Dynamics, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892, United States
| | - Marianita Santiana
- Laboratory of Host-Pathogen Dynamics, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892, United States
| | - Christopher K E Bleck
- Electron Microcopy Core, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892, United States
| | - Natthawan Chaimongkol
- Laboratory of Infectious Diseases, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, Maryland 20892, United States
| | - Nihal Altan-Bonnet
- Laboratory of Host-Pathogen Dynamics, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland 20892, United States
| | - Danmeng Shuai
- Department of Civil and Environmental Engineering, The George Washington University, Washington, District of Columbia 20052, United States
| |
Collapse
|
33
|
Majumder A, Gupta AK, Ghosal PS, Varma M. A review on hospital wastewater treatment: A special emphasis on occurrence and removal of pharmaceutically active compounds, resistant microorganisms, and SARS-CoV-2. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING 2021; 9:104812. [PMID: 33251108 PMCID: PMC7680650 DOI: 10.1016/j.jece.2020.104812] [Citation(s) in RCA: 100] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 11/10/2020] [Accepted: 11/18/2020] [Indexed: 05/05/2023]
Abstract
The hospital wastewater imposes a potent threat to the security of human health concerning its high vulnerability towards the outbreak of several diseases. Furthermore, the outbreak of COVID-19 pandemic demanded a global attention towards monitoring viruses and other infectious pathogens in hospital wastewater and their removal. Apart from that, the presence of various recalcitrant organics, pharmaceutically active compounds (PhACs), etc. imparts a complex pollution load to water resources and ecosystem. In this review, an insight into the occurrence, persistence and removal of drug-resistant microorganisms and infectious viruses as well as other micro-pollutants have been documented. The performance of various pilot/full-scale studies have been evaluated in terms of removal of biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), PhACs, pathogens, etc. It was found that many biological processes, such as membrane bioreactor, activated sludge process, constructed wetlands, etc. provided more than 80% removal of BOD, COD, TSS, etc. However, the removal of several recalcitrant organic pollutants are less responsive to those processes and demands the application of tertiary treatments, such as adsorption, ozone treatment, UV treatment, etc. Antibiotic-resistant microorganisms, viruses were found to be persistent even after the treatment of hospital wastewater, and high dose of chlorination or UV treatment was required to inactivate them. This article circumscribes the various emerging technologies, which have been used to treat PhACs and pathogens. The present review also emphasized the global concern of the presence of SARS-CoV-2 RNA in hospital wastewater and its removal by the existing treatment facilities.
Collapse
Affiliation(s)
- Abhradeep Majumder
- School of Environmental Science and Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Ashok Kumar Gupta
- Environmental Engineering Division, Department of Civil Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Partha Sarathi Ghosal
- School of Water Resources, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Mahesh Varma
- Environmental Engineering Division, Department of Civil Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
34
|
Canh VD, Torii S, Furumai H, Katayama H. Application of Capsid Integrity (RT-)qPCR to Assessing Occurrence of Intact Viruses in Surface Water and Tap Water in Japan. WATER RESEARCH 2021; 189:116674. [PMID: 33279831 DOI: 10.1016/j.watres.2020.116674] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 10/29/2020] [Accepted: 11/23/2020] [Indexed: 05/05/2023]
Abstract
Capsid integrity (RT-)qPCR has recently been developed to discriminate between intact forms from inactivated forms of viruses, but its applicability to identifying integrity of viruses in drinking water has remained limited. In this study, we investigated the application of capsid integrity (RT-)qPCR using cis-dichlorodiammineplatinum (CDDP) with sodium deoxycholate (SD) pretreatment (SD-CDDP-(RT-)qPCR) to detect intact viruses in surface water and tap water. A total of 63 water samples (surface water, n = 20; tap water, n = 43) were collected in the Kanto region in Japan and quantified by conventional (RT)-qPCR and SD-CDDP-(RT-)qPCR for pepper mild mottle virus (PMMoV) and seven other viruses pathogenic to humans (Aichivirus (AiV), noroviruses of genotypes I and II, enterovirus, adenovirus type 40 and 41, and JC and BK polyomaviruses). In surface water, PMMoV (100%) was more frequently detected than other human pathogenic viruses (30%-60%), as determined by conventional (RT-)qPCR. SD-CDDP-(RT-)qPCR also revealed that intact PMMoV (95%) was more common than intact human pathogenic viruses (20%-45%). In the tap water samples, most of the target viruses were not detected by conventional (RT-)qPCR, except for PMMoV (9%) and AiV (5%). PMMoV remained positive (5%), whereas no AiV was detected when tested by SD-CDDP-(RT-)qPCR, indicating that some PMMoV had an intact capsid, whereas AiV had damaged capsids. The presence of AiV in the absence of PMMoV in tap water produced from groundwater may demonstrate the limitation of PMMoV as a viral indicator in groundwater. In addition to being abundant in surface water, PMMoV was detected in tap water, including PMMoV with intact capsids. Thus, the absence of intact PMMoV may be used to guarantee the viral safety of tap water produced from surface water.
Collapse
Affiliation(s)
- Vu Duc Canh
- Department of Urban Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| | - Shotaro Torii
- Department of Urban Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Hiroaki Furumai
- Research Center for Water Environment Technology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Hiroyuki Katayama
- Department of Urban Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| |
Collapse
|
35
|
Torii S, Itamochi M, Katayama H. Inactivation kinetics of waterborne virus by ozone determined by a continuous quench flow system. WATER RESEARCH 2020; 186:116291. [PMID: 32836147 DOI: 10.1016/j.watres.2020.116291] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 08/07/2020] [Accepted: 08/09/2020] [Indexed: 05/22/2023]
Abstract
Ozone has a strong oxidation power that allows effective inactivation of waterborne viruses. Few studies have accurately measured the kinetic relationship between virus inactivation and ozone exposure, because the high reactivity of ozone makes it difficult to measure them simultaneously. A continuous quench flow system (CQFS) is a possible solution for analyzing such a fast reaction; however, previous studies reported that CQFS provided different results of inactivation rate constants from the batch system. The objectives of this study were (1) to develop a CQFS to evaluate the kinetics of microbial inactivation accurately, (2) to evaluate the inactivation rate constants of waterborne virus by ozone, and (3) to compare the results with previous studies. The results indicated that the simple plug flow assumption in the reaction tube of CQFS led to underestimation of the rate constants. The accurate measurement of rate constants was achieved by the pseudo-first-order reaction model that takes the residence time distribution (RTD; i.e., the laminar flow assumption) into account. The results of inactivation experiments suggested that the resistance of viruses were getting higher in the following order: Qβ < MS2, fr, GA < CVB5 Faulkner, φX-174, PV1 Sabin, CVB3 Nancy. The environmental isolates of CVB3 and CVB5 had a 2-fold higher resistance compared with their lab strains. Predicted CT values for 4-log inactivation ranged from 0.018 mg sec L-1 (Qβ) to 0.31 mg sec L-1 (CVB3 Environmental strain). The required CT values for 4-log PV1 inactivation was 0.15 mg sec L-1, which was 166-fold smaller than those reported in the United States Environmental Protection Agency guidance manuals. The overestimation in previous studies was due to the sparse assumption of RTD in the reactor. Consequently, the required ozone CT values for virus inactivation should be reconsidered to minimize the health risks and environmental costs in water treatment.
Collapse
Affiliation(s)
- Shotaro Torii
- Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, Japan.
| | - Masae Itamochi
- Department of Virology, Toyama Institute of Health, 17-1 Nakataikoyama, Imizu-shi, Toyama, Japan
| | - Hiroyuki Katayama
- Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, Japan
| |
Collapse
|
36
|
Maffettone R, Manoli K, Santoro D, Passalacqua KD, Wobus CE, Sarathy S. Performic Acid Disinfection of Municipal Secondary Effluent Wastewater: Inactivation of Murine Norovirus, Fecal Coliforms, and Enterococci. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:12761-12770. [PMID: 32835477 DOI: 10.1021/acs.est.0c05144] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Performic acid (PFA) is an emerging disinfectant to inactivate bacterial and viral microorganisms in wastewater. In this study, the inactivation kinetics of murine norovirus (MNV) by PFA, in phosphate buffer and municipal secondary effluent wastewater, are reported for the first time. PFA decay followed first-order kinetics and the inactivation of MNV was governed by the exposure of microorganisms to PFA, i.e., the integral of the PFA concentration over time (integral CT or ICT). The extension of the Chick-Watson model, in the ICT domain, described well the reduction of MNV by PFA, with determined ICT-based inactivation rate constants, kd, of 1.024 ± 0.038 L/(mg·min) and 0.482 ± 0.022 L/(mg·min) in phosphate buffer and wastewater, respectively, at pH 7.2. Furthermore, the simultaneous PFA inactivation of MNV and fecal indicators indigenously present in wastewater such as fecal coliforms and enterococci showed that 1-log reduction could be achieved with ICT of 2, 1.5, and 3.5 mg·min/L, respectively. When compared with the most commonly used peracid disinfectant of municipal wastewater, peracetic acid (PAA), the ICT requirements determined using the fitted ICT-based kinetic models were ∼20 times higher for PAA than PFA, indicating a much stronger inactivation power of the PFA molecule.
Collapse
Affiliation(s)
- Roberta Maffettone
- Department of Chemical and Biochemical Engineering, University of Western Ontario, London, Ontario N6A 5B9, Canada
- Trojan Technologies, London, Ontario N5 V 4T7, Canada
| | - Kyriakos Manoli
- Department of Chemical and Biochemical Engineering, University of Western Ontario, London, Ontario N6A 5B9, Canada
- Trojan Technologies, London, Ontario N5 V 4T7, Canada
| | - Domenico Santoro
- Department of Chemical and Biochemical Engineering, University of Western Ontario, London, Ontario N6A 5B9, Canada
- USP Technologies, London, Ontario N5 V 4T7, Canada
| | - Karla D Passalacqua
- Department of Microbiology and Immunology, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Christiane E Wobus
- Department of Microbiology and Immunology, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Siva Sarathy
- Department of Chemical and Biochemical Engineering, University of Western Ontario, London, Ontario N6A 5B9, Canada
- Trojan Technologies, London, Ontario N5 V 4T7, Canada
| |
Collapse
|