1
|
Konar S, Leung S, Tay ML, Coleman B, Dalbeth N, Cornish J, Naot D, Musson DS. Novel In Vitro Platform for Studying the Cell Response to Healthy and Diseased Tendon Matrices. ACS Biomater Sci Eng 2024; 10:3293-3305. [PMID: 38666422 DOI: 10.1021/acsbiomaterials.4c00414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2024]
Abstract
Current in vitro models poorly represent the healthy or diseased tendon microenvironment, limiting the translation of the findings to clinics. The present work aims to establish a physiologically relevant in vitro tendon platform that mimics biophysical aspects of a healthy and tendinopathic tendon matrix using a decellularized bovine tendon and to characterize tendon cells cultured using this platform. Bovine tendons were subjected to various decellularization techniques, with the efficacy of decellularization determined histologically. The biomechanical and architectural properties of the decellularized tendons were characterized using an atomic force microscope. Tendinopathy-mimicking matrices were prepared by treating the decellularized tendons with collagenase for 3 h or collagenase-chondroitinase (CC) for 1 h. The tendon tissue collected from healthy and tendinopathic patients was characterized using an atomic force microscope and compared to that of decellularized matrices. Healthy human tendon-derived cells (hTDCs) from the hamstring tendon were cultured on the decellularized matrices for 24 or 48 h, with cell morphology characterized using f-actin staining and gene expression characterized using real-time PCR. Tendon matrices prepared by freeze-thawing and 48 h nuclease treatment were fully decellularized, and the aligned structure and tendon stiffness (1.46 MPa) were maintained. Collagenase treatment prepared matrices with a disorganized architecture and reduced stiffness (0.75 MPa), mimicking chronic tendinopathy. Treatment with CC prepared matrices with a disorganized architecture without altering stiffness, mimicking early tendinopathy (1.52 MPa). hTDCs on a healthy tendon matrix were elongated, and the scleraxis (SCX) expression was maintained. On tendinopathic matrices, hTDCs had altered morphological characteristics and lower SCX expression. The expression of genes related to actin polymerization, matrix degradation and remodeling, and immune cell invasion were higher in hTDCs on tendinopathic matrices. Overall, the present study developed a physiological in vitro system to mimic healthy tendons and early and late tendinopathy, and it can be used to better understand tendon cell characteristics in healthy and diseased states.
Collapse
Affiliation(s)
- Subhajit Konar
- Department of Nutrition and Dietetics, University of Auckland, Auckland 1142, New Zealand
| | - Sophia Leung
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland 1142, New Zealand
| | - Mei Lin Tay
- Department of Surgery, University of Auckland, Auckland 1142, New Zealand
| | - Brendan Coleman
- Department of Orthopaedics, Middlemore Hospital, Auckland 1640, New Zealand
| | - Nicola Dalbeth
- Department of Medicine, University of Auckland, Auckland 1142, New Zealand
| | - Jillian Cornish
- Department of Medicine, University of Auckland, Auckland 1142, New Zealand
| | - Dorit Naot
- Department of Nutrition and Dietetics, University of Auckland, Auckland 1142, New Zealand
| | - David S Musson
- Department of Nutrition and Dietetics, University of Auckland, Auckland 1142, New Zealand
| |
Collapse
|
2
|
A Carnitine-Containing Product Improves Aspects of Post-Exercise Recovery in Adult Horses. Animals (Basel) 2023; 13:ani13040657. [PMID: 36830444 PMCID: PMC9951645 DOI: 10.3390/ani13040657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 02/03/2023] [Accepted: 02/10/2023] [Indexed: 02/16/2023] Open
Abstract
Strenuous exercise can cause tissue damage, leading to an extended recovery period. To counteract delayed post-exercise recovery, a commercial product containing L-carnitine (AID) was tested in adult horses performing consecutive exercise tests to exhaustion. Fit Thoroughbreds were administered an oral bolus of placebo (CON) or AID prior to performing an exercise test to exhaustion (D1). The heart rate (HR) and fetlock kinematics were captured throughout the exercise test. Blood was collected before, 10 min and 1, 4 and 6 h relative to exercise for the quantification of cytokine (IL1β, IL8, IL10, TNFa) gene expression and lactate concentration. Horses performed a second exercise test 48 h later (D2), with all biochemical and physiological measures repeated. The results demonstrate that the horses receiving AID retained a greater (p < 0.05) amount of flexion in the front fetlock on D2 than the horses given CON. The horses presented a reduced (p < 0.05) rate of HR decline on D2 compared to that on D1. The expression of IL1β, IL8 and IL10 increased at 1 h post-exercise on D1 and returned to baseline by 6 h; the cytokine expression pattern was not duplicated on D2. These results provide evidence of disrupted cytokine expression, HR recovery and joint mobility in response to consecutive bouts of exhaustive exercise. Importantly, AID may accelerate recovery through an undetermined mechanism.
Collapse
|
3
|
Graça AL, Gomez-Florit M, Gomes ME, Docheva D. Tendon Aging. Subcell Biochem 2023; 103:121-147. [PMID: 37120467 DOI: 10.1007/978-3-031-26576-1_7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/01/2023]
Abstract
Tendons are mechanosensitive connective tissues responsible for the connection between muscles and bones by transmitting forces that allow the movement of the body, yet, with advancing age, tendons become more prone to degeneration followed by injuries. Tendon diseases are one of the main causes of incapacity worldwide, leading to changes in tendon composition, structure, and biomechanical properties, as well as a decline in regenerative potential. There is still a great lack of knowledge regarding tendon cellular and molecular biology, interplay between biochemistry and biomechanics, and the complex pathomechanisms involved in tendon diseases. Consequently, this reflects a huge need for basic and clinical research to better elucidate the nature of healthy tendon tissue and also tendon aging process and associated diseases. This chapter concisely describes the effects that the aging process has on tendons at the tissue, cellular, and molecular levels and briefly reviews potential biological predictors of tendon aging. Recent research findings that are herein reviewed and discussed might contribute to the development of precision tendon therapies targeting the elderly population.
Collapse
Affiliation(s)
- Ana Luísa Graça
- 3B's Research Group, I3Bs-Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, Guimarães, Portugal
- ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - Manuel Gomez-Florit
- Health Research Institute of the Balearic Islands (IdISBa), Palma de Mallorca, Spain
| | - Manuela Estima Gomes
- 3B's Research Group, I3Bs-Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, Guimarães, Portugal
- ICVS/3B's-PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - Denitsa Docheva
- Department of Musculoskeletal Tissue Regeneration, Orthopaedic Hospital König-Ludwig-Haus, University of Würzburg, Würzburg, Germany.
| |
Collapse
|
4
|
Cushman DM, Petrin Z, Cummings K, Eby SF, English J, Teramoto M. Sonographic Screening of Distance Runners for the Development of Future Achilles and Patellar Tendon Pain. Clin J Sport Med 2022; 32:493-500. [PMID: 34759186 PMCID: PMC9085961 DOI: 10.1097/jsm.0000000000000984] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Accepted: 09/30/2021] [Indexed: 02/04/2023]
Abstract
OBJECTIVE The 2 primary aims of this study were to identify ultrasonographic tendon abnormalities in asymptomatic runners and to examine the likelihood of developing pain in runners with ultrasound abnormalities compared with those without abnormalities. DESIGN Longitudinal, prospective cohort study. SETTING 2019 Salt Lake City Marathon. PARTICIPANTS Recreational half-marathon and full-marathon runners. ASSESSMENT OF RISK FACTORS The Achilles and patellar tendons of asymptomatic runners were examined with ultrasound imaging before a running event. Runners were monitored for self-reported outcomes of pain in the examined tendons at 1, 3, 6, and 12 months after the event. MAIN OUTCOME MEASURES Development of pain based on the presence of asymptomatic tendon abnormalities. RESULTS One hundred thirty-eight runners (36.2 ± 12.0 years, 49.3% men, and 31.2% full-marathon runners) were included. Ultrasound abnormalities of the Achilles and patellar tendons were identified in 24.6% and 39.1% of the runners before the race, respectively. Ultrasound abnormalities were significantly associated with approximately a 3-fold increase [hazard ratio (HR) = 2.55, P = 0.004] in the hazard of developing pain in the Achilles tendon and patellar tendon (HR = 1.67, P = 0.042) over the year after the race. Positive and negative predictive values of developing pain over the year were 34.1% and 87.2%, respectively, for abnormal findings in the Achilles tendon, and 22.9% and 85.0%, respectively, for the patellar tendon. CONCLUSIONS The presence of ultrasonographic abnormalities is associated with increased development of pain in the Achilles and patellar tendons within 1 year of a marathon or half marathon.
Collapse
Affiliation(s)
- Daniel M Cushman
- Division of Physical Medicine & Rehabilitation, University of Utah, Salt Lake City, Utah
| | - Ziva Petrin
- Department of Physical Medicine & Rehabilitation, Rutgers New Jersey Medical School, Bellevue, Washington
| | - Keith Cummings
- Proliance Orthopaedics & Sports Medicine, Bellevue, Washington; and
| | - Sarah F Eby
- Division of Physical Medicine & Rehabilitation, University of Utah, Salt Lake City, Utah
| | - Joy English
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah
| | - Masaru Teramoto
- Division of Physical Medicine & Rehabilitation, University of Utah, Salt Lake City, Utah
| |
Collapse
|
5
|
Abstract
Tendons are collagen-rich musculoskeletal tissues that possess the mechanical strength needed to transfer forces between muscles and bones. The mechanical development and function of tendons are impacted by collagen crosslinks. However, there is a limited understanding of how collagen crosslinking is regulated in tendon during development and aging. Therefore, the objective of the present review was to highlight potential regulators of enzymatic and non-enzymatic collagen crosslinking and how they impact tendon function. The main collagen crosslinking enzymes include lysyl oxidase (LOX) and the lysyl oxidase-like isoforms (LOXL), whereas non-enzymatic crosslinking is mainly mediated by the formation of advanced glycation end products (AGEs). Regulators of the LOX and LOXL enzymes may include mechanical stimuli, mechanotransducive cell signaling pathways, sex hormones, transforming growth factor (TGF)β family, hypoxia, and interactions with intracellular or extracellular proteins. AGE accumulation in tendon is due to diabetic conditions and aging, and can be mediated by diet and mechanical stimuli. The formation of these enzymatic and non-enzymatic collagen crosslinks plays a major role in tendon biomechanics and in the mechanisms of force transfer. A more complete understanding of how enzymatic and non-enzymatic collagen crosslinking is regulated in tendon will better inform tissue engineering and regenerative therapies aimed at restoring the mechanical function of damaged tendons.
Collapse
Affiliation(s)
- A.J. Ellingson
- Chemical and Biological Engineering, University of Idaho, Moscow, ID, USA
| | - N.M. Pancheri
- Chemical and Biological Engineering, University of Idaho, Moscow, ID, USA
| | - N.R. Schiele
- Chemical and Biological Engineering, University of Idaho, Moscow, ID, USA,Address for correspondence: Nathan R. Schiele, Chemical and Biological Engineering, University of Idaho, 875 Perimeter Dr. MS 0904, Moscow, ID, USA. Telephone number: 208 8859063
| |
Collapse
|
6
|
Chatterjee M, Muljadi PM, Andarawis-Puri N. The role of the tendon ECM in mechanotransduction: disruption and repair following overuse. Connect Tissue Res 2022; 63:28-42. [PMID: 34030531 DOI: 10.1080/03008207.2021.1925663] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Purpose: Tendon overuse injuries are prevalent conditions with limited therapeutic options to halt disease progression. The specialized extracellular matrix (ECM) both enables joint function and mediates mechanical signals to tendon cells, driving biological responses to exercise or injury. With overuse, tendon ECM composition and structure changes at multiple scales, disrupting mechanotransduction and resulting in inadequate repair and disease progression. This review highlights the multiscale ECM changes that occur with tendon overuse and corresponding effects on cell-matrix interactions and cellular response to load.Results: Different functional joint requirements and tendon types experience a wide range of loading profiles, creating varied downstream mechanical stimuli. Distinct ECM structure and mechanical properties within the fascicle matrix, interfascicle matrix, and enthesis and their varied disruption with overuse are considered. The pericellular matrix (PCM) comprising the microscale tendon cell environment has a unique composition that changes with overuse injury and exercise, suggesting an important role in mechanotransduction and promoting repair. Cell-matrix interactions are mediated by structures including cilia, integrins, connexins and cytoskeleton that signal downstream homeostasis, adaptation, or repair. ECM disruption with tendon overuse may cause altered mechanical loading and cell-matrix interactions, resulting in mechanobiological understimulation, apoptosis, and ineffective repair. Current interventions to promote repair of tendon overuse injuries including exercise, targeting cell signaling, and modulating inflammation are considered.Conclusion: Future therapeutics should be assessed with regard of their effects on multiscale mechanotransduction in addition to joint function, with consideration of the central role of ECM.
Collapse
Affiliation(s)
- Monideepa Chatterjee
- Nancy E. And Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Patrick M Muljadi
- Nancy E. And Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Nelly Andarawis-Puri
- Nancy E. And Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA.,Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, New York, USA.,Hospital for Special Surgery, New York, New York, USA
| |
Collapse
|
7
|
Ali OJ, Ehrle A, Comerford EJ, Canty-Laird EG, Mead A, Clegg PD, Maddox TW. Intrafascicular chondroid-like bodies in the ageing equine superficial digital flexor tendon comprise glycosaminoglycans and type II collagen. J Orthop Res 2021; 39:2755-2766. [PMID: 33580534 DOI: 10.1002/jor.25002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 12/24/2020] [Accepted: 01/29/2021] [Indexed: 02/04/2023]
Abstract
The superficial digital flexor tendon (SDFT) is considered functionally equivalent to the human Achilles tendon. Circular chondroid depositions scattered amongst the fascicles of the equine SDFT are rarely reported. The purpose of this study was the detailed characterization of intrafascicular chondroid-like bodies (ICBs) in the equine SDFT, and the assessment of the effect of ageing on the presence and distribution of these structures. Ultrahigh field magnetic resonance imaging (9.4T) series of SDFT samples of young (1-9 years) and aged (17-25 years) horses were obtained, and three-dimensional reconstruction of ICBs was performed. Morphological evaluation of the ICBs included histology, immunohistochemistry and transmission electron microscopy. The number, size, and position of ICBs was determined and compared between age groups. There was a significant difference (p = .008) in the ICB count between young and old horses with ICBs present in varying number (13-467; median = 47, mean = 132.6), size and distribution in the SDFT of aged horses only. There were significantly more ICBs in the tendon periphery when compared with the tendon core region (p = .010). Histological characterization identified distinctive cells associated with increased glycosaminoglycan and type II collagen extracellular matrix content. Ageing and repetitive strain frequently cause tendon micro-damage before the development of clinical tendinopathy. Documentation of the presence and distribution of ICBs is a first step towards improving our understanding of the impact of these structures on the viscoelastic properties, and ultimately their effect on the risk of age-related tendinopathy in energy-storing tendons.
Collapse
Affiliation(s)
- Othman J Ali
- Department of Musculoskeletal Biology and Ageing Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK.,Department of Surgery and Theriogenology, College of Veterinary Medicine, University of Sulaimani, Sulaymaniyah, Sulaymaniyah, Iraq.,Department of Medical Laboratory Science, Komar University of Science and Technology, Sulaymaniyah, Kurdistan Region, Iraq
| | - Anna Ehrle
- Department of Musculoskeletal Biology and Ageing Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK
| | - Eithne J Comerford
- Department of Musculoskeletal Biology and Ageing Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK.,Institute of Infection, Veterinary and Ecological Sciences, University of Liverpool, Neston, UK.,The Medical Research Council Versus Arthritis Centre for Integrated Research into Musculoskeletal Ageing (CIMA), Institute of Ageing and Chronic Disease, Faculty of Health and Life Science, University of Liverpool, Liverpool, UK
| | - Elizabeth G Canty-Laird
- Department of Musculoskeletal Biology and Ageing Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK.,The Medical Research Council Versus Arthritis Centre for Integrated Research into Musculoskeletal Ageing (CIMA), Institute of Ageing and Chronic Disease, Faculty of Health and Life Science, University of Liverpool, Liverpool, UK
| | - Ashleigh Mead
- Institute of Infection, Veterinary and Ecological Sciences, University of Liverpool, Neston, UK
| | - Peter D Clegg
- Department of Musculoskeletal Biology and Ageing Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK.,Institute of Infection, Veterinary and Ecological Sciences, University of Liverpool, Neston, UK.,The Medical Research Council Versus Arthritis Centre for Integrated Research into Musculoskeletal Ageing (CIMA), Institute of Ageing and Chronic Disease, Faculty of Health and Life Science, University of Liverpool, Liverpool, UK
| | - Thomas W Maddox
- Department of Musculoskeletal Biology and Ageing Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK.,Institute of Infection, Veterinary and Ecological Sciences, University of Liverpool, Neston, UK
| |
Collapse
|
8
|
Cushman DM, Petrin Z, Eby S, Clements ND, Haight P, Snitily B, Teramoto M. Ultrasound evaluation of the patellar tendon and Achilles tendon and its association with future pain in distance runners. PHYSICIAN SPORTSMED 2021; 49:410-419. [PMID: 33153352 PMCID: PMC8648045 DOI: 10.1080/00913847.2020.1847004] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Objectives: To examine whether asymptomatic ultrasonographic abnormalities in the Achilles and patellar tendons in runners are associated with an increased risk of pain development.Methods: This is a longitudinal, prospective cohort study with 139 runners recruited at a half and full marathon race. Ultrasound examination of the Achilles and patellar tendons was performed bilaterally the day prior to the race. Self-reported injury data were collected at 1, 3, 6 and 12 months. 104 (74.8%) runners were included in the data analysis.Results: Ultrasonographic tendon abnormalities were found in 24.1% of the Achilles and in 23.1% of the patellar tendons prior to the race. Runners with tendon abnormality were 2-3 times more likely to develop pain within 12 months than those without (relative risk = 3.14, p = 0.010 for Achilles; relative risk = 2.52, p = 0.008 for patellar tendon). After adjusting for gender, age, years of running, average miles per week of running over a year, and pre-race pain, runners with ultrasound abnormality were about 3 times (hazard ratio = 2.89, p = 0.039 for Achilles; hazard ratio = 2.73, p = 0.030 for patellar tendon) more likely to develop pain after the race. Tendon delamination was most strongly associated with pain in both the Achilles (relative risk = 6.00; p = 0.001) and patellar tendons (relative risk = 3.81; p = 0.001).Conclusions: Structural changes in asymptomatic tendons were found in almost 25% of runners. Presence of structural changes was associated with increased development of Achilles and patellar tendon pain within one year.
Collapse
Affiliation(s)
- Daniel M Cushman
- University of Utah Division of Physical Medicine & Rehabilitation
| | - Ziva Petrin
- Rutgers New Jersey Medical School, Department of Physical Medicine & Rehabilitation
| | - Sarah Eby
- University of Utah Division of Physical Medicine & Rehabilitation
| | - Nathan D. Clements
- University of Texas, San Antonio, Department of Physical Medicine & Rehabilitation
| | | | | | - Masaru Teramoto
- University of Utah Division of Physical Medicine & Rehabilitation
| |
Collapse
|
9
|
Patel D, Zamboulis DE, Spiesz EM, Birch HL, Clegg PD, Thorpe CT, Screen HR. Structure-function specialisation of the interfascicular matrix in the human achilles tendon. Acta Biomater 2021; 131:381-390. [PMID: 34271169 PMCID: PMC8388240 DOI: 10.1016/j.actbio.2021.07.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 06/14/2021] [Accepted: 07/08/2021] [Indexed: 01/24/2023]
Abstract
Tendon consists of highly aligned collagen-rich fascicles surrounded by interfascicular matrix (IFM). Some tendons act as energy stores to improve locomotion efficiency, but such tendons commonly obtain debilitating injuries. In equine tendons, energy storing is achieved primarily through specialisation of the IFM. However, no studies have investigated IFM structure-function specialisation in human tendons. Here, we compare the human positional anterior tibial tendon and energy storing Achilles tendons, testing the hypothesis that the Achilles tendon IFM has specialised composition and mechanical properties, which are lost with ageing. Data demonstrate IFM specialisation in the energy storing Achilles, with greater elasticity and fatigue resistance than in the positional anterior tibial tendon. With ageing, alterations occur predominantly to the proteome of the Achilles IFM, which are likely responsible for the observed trends towards decreased fatigue resistance. Knowledge of these key energy storing specialisations and their changes with ageing offers crucial insight towards developing treatments for tendinopathy. Statement of significance Developing effective therapeutics or preventative measures for tendon injury necessitates the understanding of healthy tendon function and mechanics. By establishing structure-function relationships in human tendon and determining how these are affected by ageing, potential targets for therapeutics can be identified. In this study, we have used a combination of mechanical testing, immunolabelling and proteomics analysis to study structure-function specialisations in human tendon. We demonstrate that the interfascicular matrix is specialised for energy storing in the Achilles tendon, and that its proteome is altered with ageing, which is likely responsible for the observed trends towards decreased fatigue resistance. Knowledge of these key energy storing specialisations and their changes with ageing offers crucial insight towards developing treatments and preventative approaches for tendinopathy.
Collapse
|
10
|
Wagner FC, Reese S, Gerlach K, Böttcher P, Mülling CKW. Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy. BMC Vet Res 2021; 17:223. [PMID: 34172051 PMCID: PMC8229380 DOI: 10.1186/s12917-021-02914-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Accepted: 05/24/2021] [Indexed: 01/20/2023] Open
Abstract
Background Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim of this study was to develop a clamping device that enables repetitive cyclic tensile testing of equine superficial digital flexor tendon for at least 60 loading cycles and for 5 min. Results A novel cryo-clamp was developed and built. Healthy and collagenase-treated pony SDFTs were mounted in the custom-made cryo-clamp for the proximal tendon end and a special clamping device for the short pastern bone (os coronale). Simultaneously with tensile testing, we used a biplanar high-speed fluoroscopy system (FluoKin) to track tendon movement. The FluoKin system was additionally validated in precision measurements. During the cyclic tensile tests of the SDFTs, the average maximal force measured was 325 N and 953 N for a length variation of 2 and 4 % respectively. The resulting stress averaged 16 MPa and 48 MPa respectively, while the modulus of elasticity was 828 MPa and 1212 MPa respectively. Length variation of the metacarpal region was, on average, 4.87 % higher after incubation with collagenase. The precision of the FluoKin tracking was 0.0377 mm, defined as the standard deviation of pairwise intermarker distances embedded in rigid bodies. The systems accuracy was 0.0287 mm, which is the difference between the machined and mean measured distance. Conclusion In this study, a good performing clamping technique for equine tendons under repetitive cyclic loading conditions is described. The presented cryo-clamps were tested up to 50 min duration and up to the machine maximal capacity of 10 kN. With the possibility of repetitive loading a stabilization of the time-force-curve and changes of hysteresis and creep became obvious after a dozen cycles, which underlines the necessity of repetitive cyclical testing. Furthermore, biplanar high-speed fluoroscopy seems an appropriate and highly precise measurement tool for analysis of tendon behaviour under repetitive load in equine SDFTs. Supplementary Information The online version contains supplementary material available at 10.1186/s12917-021-02914-w.
Collapse
Affiliation(s)
- Franziska C Wagner
- Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 43, 04103, Leipzig, Germany.
| | - Sven Reese
- Chair of Anatomy, Histology and Embryology, Department of Veterinary Sciences, LMU Munich, Veterinärstraße 13, 80539, Munich, Germany
| | - Kerstin Gerlach
- Department for Horses, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 21, 04103, Leipzig, Germany
| | - Peter Böttcher
- Small Animal Clinic, Department of Veterinary Medicine, Freie Universität Berlin, Oertzenweg 19 b, 14163, Berlin, Germany
| | - Christoph K W Mülling
- Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 43, 04103, Leipzig, Germany
| |
Collapse
|
11
|
O'Brien C, Marr N, Thorpe C. Microdamage in the equine superficial digital flexor tendon. Equine Vet J 2021; 53:417-430. [PMID: 32772396 DOI: 10.1111/evj.13331] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Revised: 06/02/2020] [Accepted: 07/30/2020] [Indexed: 12/24/2022]
Abstract
The forelimb superficial digital flexor tendon (SDFT) is an energy-storing tendon that is highly susceptible to injury during activities such as galloping and jumping, such that it is one of the most commonly reported causes of lameness in the performance horse. This review outlines the biomechanical and biothermal effects of strain on the SDFT and how these contribute to the accumulation of microdamage. The effect of age-related alterations on strain response and subsequent injury risk is also considered. Given that tendon is a slowly healing and poorly regenerative tissue, prompt detection of early stages of pathology in vivo and timely adaptations to training protocols are likely to have a greater outcome than advances in treatment. Early screening tools and detection protocols could subsequently be of benefit in identifying subclinical signs of degeneration during the training programme. This provides an opportunity for preventative strategies to be implemented to minimise incidences of SDFT injury and reduce recovery periods in elite performance horses. Therefore, this review will focus on the modalities available to implement early screening and prevention protocols as opposed to methods to diagnose and treat injuries.
Collapse
Affiliation(s)
| | - Neil Marr
- Department of Comparative Biomedical Sciences, Royal Veterinary College, London, UK
| | - Chavaunne Thorpe
- Department of Comparative Biomedical Sciences, Royal Veterinary College, London, UK
| |
Collapse
|
12
|
Marr N, Hopkinson M, Hibbert AP, Pitsillides AA, Thorpe CT. Bimodal Whole-Mount Imaging of Tendon Using Confocal Microscopy and X-ray Micro-Computed Tomography. Biol Proced Online 2020; 22:13. [PMID: 32624710 PMCID: PMC7329428 DOI: 10.1186/s12575-020-00126-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 06/21/2020] [Indexed: 12/25/2022] Open
Abstract
Background Three-dimensional imaging modalities for optically dense connective tissues such as tendons are limited and typically have a single imaging methodological endpoint. Here, we have developed a bimodal procedure utilising fluorescence-based confocal microscopy and x-ray micro-computed tomography for the imaging of adult tendons to visualise and analyse extracellular sub-structure and cellular composition in small and large animal species. Results Using fluorescent immunolabelling and optical clearing, we visualised the expression of the novel cross-species marker of tendon basement membrane, laminin-α4 in 3D throughout whole rat Achilles tendons and equine superficial digital flexor tendon 5 mm segments. This revealed a complex network of laminin-α4 within the tendon core that predominantly localises to the interfascicular matrix compartment. Furthermore, we implemented a chemical drying process capable of creating contrast densities enabling visualisation and quantification of both fascicular and interfascicular matrix volume and thickness by x-ray micro-computed tomography. We also demonstrated that both modalities can be combined using reverse clarification of fluorescently labelled tissues prior to chemical drying to enable bimodal imaging of a single sample. Conclusions Whole-mount imaging of tendon allowed us to identify the presence of an extensive network of laminin-α4 within tendon, the complexity of which cannot be appreciated using traditional 2D imaging techniques. Creating contrast for x-ray micro-computed tomography imaging of tendon using chemical drying is not only simple and rapid, but also markedly improves on previously published methods. Combining these methods provides the ability to gain spatio-temporal information and quantify tendon substructures to elucidate the relationship between morphology and function.
Collapse
Affiliation(s)
- Neil Marr
- Comparative Biomedical Sciences, Royal Veterinary College, Royal College Street, London, UK
| | - Mark Hopkinson
- Comparative Biomedical Sciences, Royal Veterinary College, Royal College Street, London, UK
| | - Andrew P Hibbert
- Comparative Biomedical Sciences, Royal Veterinary College, Royal College Street, London, UK
| | - Andrew A Pitsillides
- Comparative Biomedical Sciences, Royal Veterinary College, Royal College Street, London, UK
| | - Chavaunne T Thorpe
- Comparative Biomedical Sciences, Royal Veterinary College, Royal College Street, London, UK
| |
Collapse
|
13
|
Zuskov A, Freedman BR, Gordon JA, Sarver JJ, Buckley MR, Soslowsky LJ. Tendon Biomechanics and Crimp Properties Following Fatigue Loading Are Influenced by Tendon Type and Age in Mice. J Orthop Res 2020; 38:36-42. [PMID: 31286548 PMCID: PMC6917867 DOI: 10.1002/jor.24407] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Accepted: 06/25/2019] [Indexed: 02/04/2023]
Abstract
In tendon, type-I collagen assembles together into fibrils, fibers, and fascicles that exhibit a wavy or crimped pattern that uncrimps with applied tensile loading. This structural property has been observed across multiple tendons throughout aging and may play an important role in tendon viscoelasticity, response to fatigue loading, healing, and development. Previous work has shown that crimp is permanently altered with the application of fatigue loading. This opens the possibility of evaluating tendon crimp as a clinical surrogate of tissue damage. The purpose of this study was to determine how fatigue loading in tendon affects crimp and mechanical properties throughout aging and between tendon types. Mouse patellar tendons (PT) and flexor digitorum longus (FDL) tendons were fatigue loaded while an integrated plane polariscope simultaneously assessed crimp properties at P150 and P570 days of age to model mature and aged tendon phenotypes (N = 10-11/group). Tendon type, fatigue loading, and aging were found to differentially affect tendon mechanical and crimp properties. FDL tendons had higher modulus and hysteresis, whereas the PT showed more laxity and toe region strain throughout aging. Crimp frequency was consistently higher in FDL compared with PT throughout fatigue loading, whereas the crimp amplitude was cycle dependent. This differential response based on tendon type and age further suggests that the FDL and the PT respond differently to fatigue loading and that this response is age-dependent. Together, our findings suggest that the mechanical and structural effects of fatigue loading are specific to tendon type and age in mice. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:36-42, 2020.
Collapse
Affiliation(s)
- Andrey Zuskov
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
- Department of Orthopaedic Surgery, Wake Forest School of Medicine, Winston-Salem, NC, USA
| | - Benjamin R. Freedman
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA
| | - Joshua A. Gordon
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
| | - Joseph J. Sarver
- Department of Biomedical Engineering, Drexel University, Philadelphia, PA, USA
| | - Mark R. Buckley
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, USA
| | - Louis J. Soslowsky
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
14
|
Muench JR, Thelen DG, Henak CR. Interfibrillar shear behavior is altered in aging tendon fascicles. Biomech Model Mechanobiol 2019; 19:841-849. [PMID: 31707625 DOI: 10.1007/s10237-019-01251-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Accepted: 11/04/2019] [Indexed: 12/11/2022]
Abstract
Tendon elongation involves both stretching and sliding between adjacent fascicles and fibers. Hence, age-related changes in tendon matrix properties may alter sliding behavior and thereby affect injury thresholds. The objective of this study was to investigate the effects of age on interfibrillar shear behavior in partial cut tendon fascicles. Cine microscopic imaging was used to track deformation patterns of intact and partial cut fascicles from mature (9 months, n = 10) and aged (32 months, n = 10) rat tail tendons. Finite element (FE) models coupled with experimental data provided insight into age-related changes in tissue constitutive properties that could give rise to age-dependent behavior. Intact fascicles from aged tendons exhibited a 28% lower linear region modulus and reduced toe region when compared to fascicles from mature tendons. Partial cut tendon fascicles consistently exhibited a shearing plane that extended longitudinally from the tip of the cut. Both mature and aged fascicles exhibited distinct failure that was observable in differential displacement across the shearing plane. However, aged fascicles exhibited 11-20% higher grip-to-grip strain at failure and tended to exhibit more variable and greater differential displacement at failure, when compared to mature fascicles. FE models suggest that this age-related change in shear behavior arises from a reduction in interfibrillar shear modulus with age. These data suggest that aging alters interfibrillar failure mechanisms and hence may contribute to the increased propensity for injury that is commonly seen in older tendons.
Collapse
Affiliation(s)
- Jared R Muench
- Department of Mechanical Engineering, University of Wisconsin-Madison, 3031 Mechanical Engineering Building, 1513 University Avenue, Madison, WI, 53706, USA
| | - Darryl G Thelen
- Department of Mechanical Engineering, University of Wisconsin-Madison, 3031 Mechanical Engineering Building, 1513 University Avenue, Madison, WI, 53706, USA.,Department of Biomedical Engineering, University of Wisconsin-Madison, 1550 Engineering Drive, Madison, WI, USA.,Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI, USA
| | - Corinne R Henak
- Department of Mechanical Engineering, University of Wisconsin-Madison, 3031 Mechanical Engineering Building, 1513 University Avenue, Madison, WI, 53706, USA. .,Department of Biomedical Engineering, University of Wisconsin-Madison, 1550 Engineering Drive, Madison, WI, USA. .,Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI, USA.
| |
Collapse
|
15
|
Lee AH, Elliott DM. Multi-Scale Loading and Damage Mechanisms of Plantaris and Rat Tail Tendons. J Orthop Res 2019; 37:1827-1837. [PMID: 30977538 PMCID: PMC6790141 DOI: 10.1002/jor.24309] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2018] [Revised: 02/21/2019] [Accepted: 03/13/2019] [Indexed: 02/04/2023]
Abstract
Tendinopathy, degeneration of the tendon that leads to pain and dysfunction, is common in both sports and occupational settings, but multi-scale mechanisms for tendinopathy are still unknown. We recently showed that micro-scale sliding (shear) is responsible for both load transfer and damage mechanisms in the rat tail tendon; however, the rat tail tendon is a specialized non-load-bearing tendon, and thus the load transfer and damage mechanisms are still unknown for load-bearing tendons. The objective of this study was to investigate the load transfer and damage mechanisms of load-bearing tendons using the rat plantaris tendon. We demonstrated that micro-scale sliding is a key component for both mechanisms in the plantaris tendon, similar to the tail tendon. Namely, the micro-scale sliding was correlated with applied strain, demonstrating that load was transferred via micro-scale sliding in the plantaris and tail tendons. In addition, while the micro-scale strain fully recovered, the micro-scale sliding was non-recoverable and strain-dependent, and correlated with tissue-scale mechanical parameters. When the applied strain was normalized, the % magnitudes of non-recoverable sliding was similar between the plantaris and tail tendons. Statement of clinical significance: Understanding the mechanisms responsible for the pathogenesis and progression of tendinopathy can improve prevention and rehabilitation strategies and guide therapies and the design of engineered constructs. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1827-1837, 2019.
Collapse
Affiliation(s)
| | - Dawn M. Elliott
- Corresponding author: Tel.: +1 302 831 1295, Address: 161 Colburn Lab, 150 Academy Street, Newark, DE 19716, United States., (D.M. Elliott)
| |
Collapse
|
16
|
Karathanasopoulos N, Ganghoffer JF. Exploiting Viscoelastic Experimental Observations and Numerical Simulations to Infer Biomimetic Artificial Tendon Fiber Designs. Front Bioeng Biotechnol 2019; 7:85. [PMID: 31134193 PMCID: PMC6513967 DOI: 10.3389/fbioe.2019.00085] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Accepted: 04/05/2019] [Indexed: 11/18/2022] Open
Abstract
Designing biomimetic artificial tendons requires a thorough, data-based understanding of the tendon's inner material properties. The current work exploits viscoelastic experimental observations at the tendon fascicle scale, making use of mechanical and data analysis methods. More specifically, based on reported elastic, volumetric and relaxation fascicle scale properties, we infer most probable, mechanically compatible material attributes at the fiber scale. In particular, the work provides pairs of elastic and viscous fiber-scale moduli, which can reproduce the upper scale tendon mechanics. The computed range of values for the fiber-scale tendon viscosity attest to the substantial stress relaxation capabilities of tendons. More importantly, the reported mechanical parameters constitute a basis for the design of tendon-specific restoration materials, such as fiber-based, engineering scaffolds.
Collapse
|
17
|
Titan A, Andarawis-Puri N. Tendinopathy: Investigating the Intersection of Clinical and Animal Research to Identify Progress and Hurdles in the Field. JBJS Rev 2018; 4:01874474-201610000-00002. [PMID: 27792676 DOI: 10.2106/jbjs.rvw.15.00088] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Biological treatments, surgical interventions, and rehabilitation exercises have been successfully used to treat tendinopathy, but the development of effective treatments has been hindered by the lack of mechanistic data regarding the pathogenesis of the disease. While insightful, clinical studies are limited in their capacity to provide data regarding the pathogenesis of tendinopathies, emphasizing the value of animal models and cell culture studies to fill this essential gap in knowledge. Clinical pathological findings from imaging studies or histological analysis are not universal across patients with tendinopathy and have not been clearly associated with the onset of symptoms. There are several unresolved controversies, including the cellular changes that accompany the tendinopathic disease state and the role of inflammation. Additional research is needed to correlate the manifestations of the disease with its pathogenesis, with the goal of reaching a field-wide consensus on the pathology of the disease state. Such a consensus will allow standardized clinical practices to more effectively diagnose and treat tendinopathy.
Collapse
Affiliation(s)
- Ashley Titan
- Leni and Peter W. May Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, New York, NY
| | | |
Collapse
|
18
|
Freedman BR, Rodriguez AB, Leiphart RJ, Newton JB, Ban E, Sarver JJ, Mauck RL, Shenoy VB, Soslowsky LJ. Dynamic Loading and Tendon Healing Affect Multiscale Tendon Properties and ECM Stress Transmission. Sci Rep 2018; 8:10854. [PMID: 30022076 PMCID: PMC6052000 DOI: 10.1038/s41598-018-29060-y] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Accepted: 06/26/2018] [Indexed: 12/15/2022] Open
Abstract
The extracellular matrix (ECM) is the primary biomechanical environment that interacts with tendon cells (tenocytes). Stresses applied via muscle contraction during skeletal movement transfer across structural hierarchies to the tenocyte nucleus in native uninjured tendons. Alterations to ECM structural and mechanical properties due to mechanical loading and tissue healing may affect this multiscale strain transfer and stress transmission through the ECM. This study explores the interface between dynamic loading and tendon healing across multiple length scales using living tendon explants. Results show that macroscale mechanical and structural properties are inferior following high magnitude dynamic loading (fatigue) in uninjured living tendon and that these effects propagate to the microscale. Although similar macroscale mechanical effects of dynamic loading are present in healing tendon compared to uninjured tendon, the microscale properties differed greatly during early healing. Regression analysis identified several variables (collagen and nuclear disorganization, cellularity, and F-actin) that directly predict nuclear deformation under loading. Finite element modeling predicted deficits in ECM stress transmission following fatigue loading and during healing. Together, this work identifies the multiscale response of tendon to dynamic loading and healing, and provides new insight into microenvironmental features that tenocytes may experience following injury and after cell delivery therapies.
Collapse
Affiliation(s)
- Benjamin R Freedman
- McKay Orthopedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA.,Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA, USA.,John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA.,Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA, USA
| | - Ashley B Rodriguez
- McKay Orthopedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
| | - Ryan J Leiphart
- McKay Orthopedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA.,Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA, USA
| | - Joseph B Newton
- McKay Orthopedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA.,Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA, USA
| | - Ehsan Ban
- Department of Materials Science and Engineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA, USA.,Center for Engineering Mechanobiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Joseph J Sarver
- Department of Biomedical Engineering, Drexel University, Philadelphia, PA, USA
| | - Robert L Mauck
- McKay Orthopedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA.,Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA, USA
| | - Vivek B Shenoy
- Department of Materials Science and Engineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA, USA.,Center for Engineering Mechanobiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Louis J Soslowsky
- McKay Orthopedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA. .,Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|
19
|
Spiesz EM, Thorpe CT, Thurner PJ, Screen HRC. Structure and collagen crimp patterns of functionally distinct equine tendons, revealed by quantitative polarised light microscopy (qPLM). Acta Biomater 2018; 70:281-292. [PMID: 29409868 PMCID: PMC5894809 DOI: 10.1016/j.actbio.2018.01.034] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Revised: 01/19/2018] [Accepted: 01/24/2018] [Indexed: 01/15/2023]
Abstract
Structure-function relationships in tendons are directly influenced by the arrangement of collagen fibres. However, the details of such arrangements in functionally distinct tendons remain obscure. This study demonstrates the use of quantitative polarised light microscopy (qPLM) to identify structural differences in two major tendon compartments at the mesoscale: fascicles and interfascicular matrix (IFM). It contrasts functionally distinct positional and energy storing tendons, and considers changes with age. Of particular note, the technique facilitates the analysis of crimp parameters, in which cutting direction artefact can be accounted for and eliminated, enabling the first detailed analysis of crimp parameters across functionally distinct tendons. IFM shows lower birefringence (0.0013 ± 0.0001 [−]), as compared to fascicles (0.0044 ± 0.0005 [−]), indicating that the volume fraction of fibres must be substantially lower in the IFM. Interestingly, no evidence of distinct fibre directional dispersions between equine energy storing superficial digital flexor tendons (SDFTs) and positional common digital extensor tendons (CDETs) were noted, suggesting either more subtle structural differences between tendon types or changes focused in the non-collagenous components. By contrast, collagen crimp characteristics are strongly tendon type specific, indicating crimp specialisation is crucial in the respective mechanical function. SDFTs showed much finer crimp (21.1 ± 5.5 µm) than positional CDETs (135.4 ± 20.1 µm). Further, tendon crimp was finer in injured tendon, as compared to its healthy equivalents. Crimp angle differed strongly between tendon types as well, with average of 6.5 ± 1.4° in SDFTs and 13.1 ± 2.0° in CDETs, highlighting a substantially tighter crimp in the SDFT, likely contributing to its effective recoil capacity. Statement of Significance This is the first study to quantify birefringence in fascicles and interfascicular matrix of functionally distinct energy storing and positional tendons. It adopts a novel method – quantitative polarised light microscopy (qPLM) to measure collagen crimp angle, avoiding artefacts related to the direction of histological sectioning, and provides the first direct comparison of crimp characteristics of functionally distinct tendons of various ages. A comparison of matched picrosirius red stained and unstained tendons sections identified non-homogenous staining effects, and leads us to recommend that only unstained sections are analysed in the quantitative manner. qPLM is successfully used to assess birefringence in soft tissue sections, offering a promising tool for investigating the structural arrangements of fibres in (soft) tissues and other composite materials.
Collapse
Affiliation(s)
- Ewa M Spiesz
- School of Engineering and Materials Science, Queen Mary University of London, Mile End Rd, London E1 4NS, United Kingdom; Department of Bionanoscience, Kavli Institute of Nanoscience, Delft University of Technology, Van der Maasweg 9, 2629 HZ Delft, The Netherlands.
| | - Chavaunne T Thorpe
- School of Engineering and Materials Science, Queen Mary University of London, Mile End Rd, London E1 4NS, United Kingdom; Comparative Biomedical Sciences, Royal Veterinary College, Royal College Street, London NW1 0TU, United Kingdom.
| | - Philipp J Thurner
- Institute of Lightweight Design and Structural Biomechanics, TU Wien, Getreidemarkt 9, A-1060 Vienna, Austria.
| | - Hazel R C Screen
- School of Engineering and Materials Science, Queen Mary University of London, Mile End Rd, London E1 4NS, United Kingdom.
| |
Collapse
|
20
|
Slane LC, Bogaerts S, Thelen DG, Scheys L. Nonuniform Deformation of the Patellar Tendon During Passive Knee Flexion. J Appl Biomech 2018; 34:14-22. [PMID: 28787221 DOI: 10.1123/jab.2017-0067] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The purpose of this study was to evaluate localized patterns of patellar tendon deformation during passive knee flexion. Ultrasound radiofrequency data were collected from the patellar tendons of 20 healthy young adults during knee flexion over a range of motion of 50°-90° of flexion. A speckle tracking approach was used to compute proximal and distal tendon displacements and elongations. Nonuniform tissue displacements were visible in the proximal tendon (P < .001), with the deep tendon undergoing more distal displacement than the superficial tendon. In the distal tendon, more uniform tendon motion was observed. Spatial variations in percent elongation were also observed, but these varied along the length of the tendon (P < .002), with the proximal tendon remaining fairly isometric while the distal tendon underwent slight elongation. These results suggest that even during passive flexion the tendon undergoes complex patterns of deformation. Proximal tendon nonuniformity may arise from its complex anatomy where the deep tendon inserts onto the patella and the superficial tendon extends to the quadriceps tendon. Such heterogeneity is not captured in whole tendon average assessments, emphasizing the relevance of considering localized tendon mechanics, which may be key to understanding tendon behavior and precursors to injury and disease.
Collapse
|
21
|
Turlo AJ, Ashraf Kharaz Y, Clegg PD, Anderson J, Peffers MJ. Donor age affects proteome composition of tenocyte-derived engineered tendon. BMC Biotechnol 2018; 18:2. [PMID: 29338716 PMCID: PMC5771075 DOI: 10.1186/s12896-018-0414-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2017] [Accepted: 01/03/2018] [Indexed: 12/27/2022] Open
Abstract
Background The concept of tissue engineering is to deliver to the injury site biological scaffolds carrying functional cells that will enhance healing response. The preferred cell source is autologous in order to reduce immune response in the treated individual. However, in elderly patients age-related changes in synthetic activity of the implanted cells and subsequent alterations in tissue protein content may affect therapeutic outcomes. In this study we investigated the effect of donor age on proteome composition of tenocyte-derived tendon tissue-engineered constructs. Results Liquid chromatography tandem mass spectrometry was used to assess the proteome of tissue-engineered constructs derived from young and old equine tenocytes. Ageing was associated with altered extracellular matrix composition, especially accumulation of collagens (type I, III and XIV), and lower cytoskeletal turnover. Proteins involved in cell responsiveness to mechanical stimuli and cell-extracellular matrix interaction (calponin 1, palladin, caldesmon 1, cortactin) were affected. Conclusions This study demonstrated significant changes in proteome of engineered tendon derived from young and old tenocytes, indicating the impact of donor age on composition of autologous constructs. Electronic supplementary material The online version of this article (10.1186/s12896-018-0414-5) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Agnieszka J Turlo
- Department of Pathology and Veterinary Diagnostics, Faculty of Veterinary Medicine, Warsaw University of Life Science, ul. Nowoursynowska 159c, 02-776, Warsaw, Poland.
| | - Yalda Ashraf Kharaz
- Institute of Ageing and Chronic Disease, University of Liverpool, William Duncan Building, 6 West Derby Street, Liverpool, L7 8TX, UK
| | - Peter D Clegg
- Institute of Ageing and Chronic Disease, University of Liverpool, William Duncan Building, 6 West Derby Street, Liverpool, L7 8TX, UK
| | - James Anderson
- Institute of Ageing and Chronic Disease, University of Liverpool, William Duncan Building, 6 West Derby Street, Liverpool, L7 8TX, UK
| | - Mandy J Peffers
- Institute of Ageing and Chronic Disease, University of Liverpool, William Duncan Building, 6 West Derby Street, Liverpool, L7 8TX, UK
| |
Collapse
|
22
|
Fascicles and the interfascicular matrix show decreased fatigue life with ageing in energy storing tendons. Acta Biomater 2017; 56:58-64. [PMID: 28323176 PMCID: PMC5486374 DOI: 10.1016/j.actbio.2017.03.024] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2016] [Revised: 02/09/2017] [Accepted: 03/14/2017] [Indexed: 12/27/2022]
Abstract
Tendon is composed of rope-like fascicles bound together by interfascicular matrix (IFM). The IFM is critical for the function of energy storing tendons, facilitating sliding between fascicles to allow these tendons to cyclically stretch and recoil. This capacity is required to a lesser degree in positional tendons. We have previously demonstrated that both fascicles and IFM in energy storing tendons have superior fatigue resistance compared with positional tendons, but the effect of ageing on the fatigue properties of these different tendon subunits has not been determined. Energy storing tendons become more injury-prone with ageing, indicating reduced fatigue resistance, hence we tested the hypothesis that the decline in fatigue life with ageing in energy storing tendons would be more pronounced in the IFM than in fascicles. We further hypothesised that tendon subunit fatigue resistance would not alter with ageing in positional tendons. Fascicles and IFM from young and old energy storing and positional tendons were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results show that both IFM and fascicles from the SDFT exhibit a similar magnitude of reduced fatigue life with ageing. By contrast, the fatigue life of positional tendon subunits was unaffected by ageing. The age-related decline in fatigue life of tendon subunits in energy storing tendons is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms resulting in this reduced fatigue life will aid in the development of treatments and interventions to prevent age-related tendinopathy. Statement of Significance Understanding the effect of ageing on tendon-structure function relationships is crucial for the development of effective preventative measures and treatments for age-related tendon injury. In this study, we demonstrate for the first time that the fatigue resistance of the interfascicular matrix decreases with ageing in energy storing tendons. This is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms that result in this reduced fatigue resistance will aid in the development of treatments and interventions to prevent age-related tendinopathy.
Collapse
|
23
|
Thompson MS, Bajuri MN, Khayyeri H, Isaksson H. Mechanobiological modelling of tendons: Review and future opportunities. Proc Inst Mech Eng H 2017; 231:369-377. [DOI: 10.1177/0954411917692010] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Tendons are adapted to carry large, repeated loads and are clinically important for the maintenance of musculoskeletal health in an increasing, actively ageing population, as well as in elite athletes. Tendons are known to adapt to mechanical loading. Also, their healing and disease processes are highly sensitive to mechanical load. Computational modelling approaches developed to capture this mechanobiological adaptation in tendons and other tissues have successfully addressed many important scientific and clinical issues. The aim of this review is to identify techniques and approaches that could be further developed to address tendon-related problems. Biomechanical models are identified that capture the multi-level aspects of tendon mechanics. Continuum whole tendon models, both phenomenological and microstructurally motivated, are important to estimate forces during locomotion activities. Fibril-level microstructural models are documented that can use these estimated forces to detail local mechanical parameters relevant to cell mechanotransduction. Cell-level models able to predict the response to such parameters are also described. A selection of updatable mechanobiological models is presented. These use mechanical signals, often continuum tissue level, along with rules for tissue change and have been applied successfully in many tissues to predict in vivo and in vitro outcomes. Signals may include scalars derived from the stress or strain tensors, or in poroelasticity also fluid velocity, while adaptation may be represented by changes to elastic modulus, permeability, fibril density or orientation. So far, only simple analytical approaches have been applied to tendon mechanobiology. With the development of sophisticated computational mechanobiological models in parallel with reporting more quantitative data from in vivo or clinical mechanobiological studies, for example, appropriate imaging, biochemical and histological data, this field offers huge potential for future development towards clinical applications.
Collapse
Affiliation(s)
- Mark S Thompson
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK
| | - M Nazri Bajuri
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK
- Faculty of Biosciences & Medical Engineering, Universiti Teknologi Malaysia, Johor Bahru, Malaysia
| | - Hanifeh Khayyeri
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| |
Collapse
|
24
|
Slane LC, Bogaerts S, Mihejeva I, Scheys L. Evidence of patellar tendon buckling during passive knee extension. Knee 2016; 23:801-6. [PMID: 27424277 DOI: 10.1016/j.knee.2016.06.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 06/05/2016] [Accepted: 06/15/2016] [Indexed: 02/02/2023]
Abstract
PURPOSE The purpose of this study was to investigate and describe buckling of the patellar tendon. METHODS Healthy young adults (28±4years, 10F/10M) underwent passive knee flexion/extension during the simultaneous measurement of knee angle and collection of cine ultrasound from the patellar tendon. Patellar tendon buckling was observed visually in ultrasound images, and the corresponding knee angle at which evidence of buckling disappeared was identified. RESULTS All subjects showed evidence of distal buckling which occurred on average at 23±8° flexion. Proximal buckling was only observed in fourteen subjects (10F/4M) at an average of 15±8°. Buckling patterns varied between subjects, but with high within-subject consistency. Buckling magnitude increased with age (p=0.03) and decreased with more weekly exercise (p=0.02). DISCUSSION The patellar tendon exhibited significant buckling in knee extension suggesting that buckling is a component of healthy knee function. Like tendon crimp, buckling may serve as a protective mechanism, allowing the tissue to unwrinkle prior to undergoing pure strain. The links between increased buckling magnitude and both age and reduced activity suggest that excessive buckling may be maladaptive, though future work is necessary to elucidate this relationship. Buckling is relevant to consider when estimating tendon length, as buckling can lead to significant underestimation of resting length and thus overestimation of strain. CONCLUSION This study demonstrates the complexity of tendon behavior even in healthy adults undergoing passive motion, suggesting that buckling may be relevant to an improved understanding of tendon health and pathology.
Collapse
Affiliation(s)
- Laura Chernak Slane
- KU Leuven, Institute for Orthopaedic Research and Training, Oude Markt 13, 3000 Leuven, Belgium.
| | - Stijn Bogaerts
- KU Leuven, Institute for Orthopaedic Research and Training, Oude Markt 13, 3000 Leuven, Belgium; University Hospitals Leuven, Campus Pellenberg, Weligerveld 1 Blok 1, 3212 Pellenberg, Belgium
| | - Irina Mihejeva
- KU Leuven, Institute for Orthopaedic Research and Training, Oude Markt 13, 3000 Leuven, Belgium
| | - Lennart Scheys
- KU Leuven, Institute for Orthopaedic Research and Training, Oude Markt 13, 3000 Leuven, Belgium; University Hospitals Leuven, Campus Pellenberg, Weligerveld 1 Blok 1, 3212 Pellenberg, Belgium
| |
Collapse
|
25
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HR. Fascicles and the interfascicular matrix show adaptation for fatigue resistance in energy storing tendons. Acta Biomater 2016; 42:308-315. [PMID: 27286677 PMCID: PMC5015572 DOI: 10.1016/j.actbio.2016.06.012] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Revised: 05/06/2016] [Accepted: 06/07/2016] [Indexed: 11/27/2022]
Abstract
Tendon is composed of rope-like fascicles, bound together by interfascicular matrix (IFM). Our previous work shows that the IFM is critical for tendon function, facilitating sliding between fascicles to allow tendons to stretch. This function is particularly important in energy storing tendons, which experience extremely high strains during exercise, and therefore require the capacity for considerable inter-fascicular sliding and recoil. This capacity is not required in positional tendons. Whilst we have previously described the quasi-static properties of the IFM, the fatigue resistance of the IFM in functionally distinct tendons remains unknown. We therefore tested the hypothesis that fascicles and IFM in the energy storing equine superficial digital flexor tendon (SDFT) are more fatigue resistant than those in the positional common digital extensor tendon (CDET). Fascicles and IFM from both tendon types were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results demonstrated that both fascicles and IFM from the energy storing SDFT were able to resist a greater number of cycles before failure than those from the positional CDET. Further, SDFT fascicles and IFM exhibited less hysteresis over the course of testing than their counterparts in the CDET. This is the first study to assess the fatigue resistance of the IFM, demonstrating that IFM has a functional role within tendon and contributes significantly to tendon mechanical properties. These data provide important advances into fully characterising tendon structure-function relationships. Statement of Significance Understanding tendon-structure function relationships is crucial for the development of effective preventative measures and treatments for tendon injury. In this study, we demonstrate for the first time that the interfascicular matrix is able to withstand a high degree of cyclic loading, and is specialised for improved fatigue resistance in energy storing tendons. These findings highlight the importance of the interfascicular matrix in the function of energy storing tendons, and potentially provide new avenues for the development of treatments for tendon injury which specifically target the interfascicular matrix.
Collapse
|
26
|
Connizzo BK, Han L, Birk DE, Soslowsky LJ. Collagen V-heterozygous and -null supraspinatus tendons exhibit altered dynamic mechanical behaviour at multiple hierarchical scales. Interface Focus 2016; 6:20150043. [PMID: 26855746 DOI: 10.1098/rsfs.2015.0043] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Tendons function using a unique set of mechanical properties governed by the extracellular matrix and its ability to respond to varied multi-axial loads. Reduction of collagen V expression, such as in classic Ehlers-Danlos syndrome, results in altered fibril morphology and altered macroscale mechanical function in both clinical and animal studies, yet the mechanism by which changes at the fibril level lead to macroscale functional changes has not yet been investigated. This study addresses this by defining the multiscale mechanical response of wild-type, collagen V-heterozygous and -null supraspinatus tendons. Tendons were subjected to mechanical testing and analysed for macroscale properties, as well as microscale (fibre re-alignment) and nanoscale (fibril deformation and sliding) responses. In many macroscale parameters, results showed a dose-dependent response with severely decreased properties in the null group. In addition, both heterozygous and null groups responded to load faster than in wild-type tendons via earlier fibre re-alignment and fibril stretch. However, the heterozygous group exhibited increased fibril sliding, while the null group exhibited no fibril sliding. These studies demonstrate that dynamic responses play an important role in determining overall function and that collagen V is a critical regulator in the development of these relationships.
Collapse
Affiliation(s)
- Brianne K Connizzo
- McKay Orthopaedic Research Laboratory , University of Pennsylvania , 424 Stemmler Hall, 36th and Hamilton Walk, Philadelphia, PA 19104-6081 , USA
| | - Lin Han
- School of Biomedical Engineering, Science and Health Systems , Drexel University , 3141 Chestnut Street, Philadelphia, PA 19104 , USA
| | - David E Birk
- Department of Molecular Pharmacology and Physiology , Morsani College of Medicine, University of South Florida , Tampa, FL 33612 , USA
| | - Louis J Soslowsky
- McKay Orthopaedic Research Laboratory , University of Pennsylvania , 424 Stemmler Hall, 36th and Hamilton Walk, Philadelphia, PA 19104-6081 , USA
| |
Collapse
|
27
|
Influence of Ageing on Tendon Homeostasis. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2016; 920:247-60. [DOI: 10.1007/978-3-319-33943-6_24] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
28
|
Thorpe CT, Spiesz EM, Chaudhry S, Screen HRC, Clegg PD. Science in brief: recent advances into understanding tendon function and injury risk. Equine Vet J 2015; 47:137-40. [PMID: 25644766 DOI: 10.1111/evj.12346] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- C T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, UK
| | | | | | | | | |
Collapse
|
29
|
Williamson KA, Lee KJ, Humphreys WJE, Comerford EJV, Clegg PD, Canty‐Laird EG. Restricted differentiation potential of progenitor cell populations obtained from the equine superficial digital flexor tendon (SDFT). J Orthop Res 2015; 33:849-58. [PMID: 25877997 PMCID: PMC4657492 DOI: 10.1002/jor.22891] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2014] [Accepted: 03/02/2015] [Indexed: 02/04/2023]
Abstract
The aim of this study was to characterize stem and progenitor cell populations from the equine superficial digital flexor tendon, an energy-storing tendon with similarities to the human Achilles tendon, which is frequently injured. Using published methods for the isolation of tendon-derived stem/progenitor cells by low-density plating we found that isolated cells possessed clonogenicity but were unable to fully differentiate towards mesenchymal lineages using trilineage differentiation assays. In particular, adipogenic differentiation appeared to be restricted, as assessed by Oil Red O staining of stem/progenitor cells cultured in adipogenic medium. We then assessed whether differential adhesion to fibronectin substrates could be used to isolate a population of cells with broader differentiation potential. However we found little difference in the stem and tenogenic gene expression profile of these cells as compared to tenocytes, although the expression of thrombospondin-4 was significantly reduced in hypoxic conditions. Tendon-derived stem/progenitor cells isolated by differential adhesion to fibronectin had a similar differentiation potential to cells isolated by low density plating, and when grown in either normoxic or hypoxic conditions. In summary, we have found a restricted differentiation potential of cells isolated from the equine superficial digital flexor tendon despite evidence for stem/progenitor-like characteristics.
Collapse
Affiliation(s)
- Kate Ann Williamson
- Department of Musculoskeletal BiologyInstitute of Ageing and Chronic DiseaseLeahurst CampusUniversity of LiverpoolChester High RoadNestonCH64 7TEUnited Kingdom
| | - Katie Joanna Lee
- Department of Musculoskeletal BiologyInstitute of Ageing and Chronic DiseaseLeahurst CampusUniversity of LiverpoolChester High RoadNestonCH64 7TEUnited Kingdom
| | | | - Eithne Josephine Veronica Comerford
- Department of Musculoskeletal BiologyInstitute of Ageing and Chronic DiseaseLeahurst CampusUniversity of LiverpoolChester High RoadNestonCH64 7TEUnited Kingdom
- School of Veterinary ScienceLeahurst CampusUniversity of LiverpoolChester High RoadNestonCH64 7TEUnited Kingdom
| | - Peter David Clegg
- Department of Musculoskeletal BiologyInstitute of Ageing and Chronic DiseaseLeahurst CampusUniversity of LiverpoolChester High RoadNestonCH64 7TEUnited Kingdom
- School of Veterinary ScienceLeahurst CampusUniversity of LiverpoolChester High RoadNestonCH64 7TEUnited Kingdom
- The MRC‐Arthritis Research UK Centre for Integrated research into Musculoskeletal Ageing (CIMA)LiverpoolL69 3GAUnited Kingdom
| | - Elizabeth Gail Canty‐Laird
- Department of Musculoskeletal BiologyInstitute of Ageing and Chronic DiseaseLeahurst CampusUniversity of LiverpoolChester High RoadNestonCH64 7TEUnited Kingdom
- The MRC‐Arthritis Research UK Centre for Integrated research into Musculoskeletal Ageing (CIMA)LiverpoolL69 3GAUnited Kingdom
| |
Collapse
|
30
|
Freedman BR, Zuskov A, Sarver JJ, Buckley MR, Soslowsky LJ. Evaluating changes in tendon crimp with fatigue loading as an ex vivo structural assessment of tendon damage. J Orthop Res 2015; 33:904-10. [PMID: 25773654 PMCID: PMC4416993 DOI: 10.1002/jor.22875] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Accepted: 02/13/2015] [Indexed: 02/04/2023]
Abstract
The complex structure of tendons relates to their mechanical properties. Previous research has associated the waviness of collagen fibers (crimp) during quasi-static tensile loading to tensile mechanical properties, but less is known about the role of fatigue loading on crimp properties. In this study (IACUC approved), mouse patellar tendons were fatigue loaded while an integrated plane polariscope simultaneously assessed crimp properties. We demonstrate a novel structural mechanism whereby tendon crimp amplitude and frequency are altered with fatigue loading. In particular, fatigue loading increased the crimp amplitude across the tendon width and length, and these structural alterations were shown to be both region and load dependent. The change in crimp amplitude was strongly correlated to mechanical tissue laxity (defined as the ratio of displacement and gauge length relative to the first cycle of fatigue loading assessed at constant load throughout testing), at all loads and regions evaluated. Together, this study highlights the role of fatigue loading on tendon crimp properties as a function of load applied and region evaluated, and offers an additional structural mechanism for mechanical alterations that may lead to ultimate tendon failure.
Collapse
Affiliation(s)
- Benjamin R. Freedman
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Joseph J. Sarver
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA,Department of Biomedical Engineering, Drexel University, Philadelphia, PA, USA
| | - Mark R. Buckley
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA,Department of Biomedical Engineering, University of Rochester, Rochester, NY, USA
| | - Louis J. Soslowsky
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
31
|
Mouthuy PA, Zargar N, Hakimi O, Lostis E, Carr A. Fabrication of continuous electrospun filaments with potential for use as medical fibres. Biofabrication 2015; 7:025006. [PMID: 25987265 DOI: 10.1088/1758-5090/7/2/025006] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Soft tissue injuries represent a substantial and growing social and economic burden. Medical fibres are commonly used to repair these injuries during surgery. Patient's outcomes are, however, not promising with around 40% of surgical repairs failing within the first few months after surgery due to poor tissue regeneration. The application of nanofibrous filaments and yarns as medical fibres and scaffolds has been suggested to improve soft tissue regeneration and enhance the quality of the repair. However, due to a lack of robustness and reliability of the current fabrication methods, continuous nanofibrous filaments cannot be manufactured and scaled up in industrial settings and are not currently available for clinical use. We have developed a robust and automated method that enables the manufacture of continuous electrospun filaments and which has the potential to be integrated into existing textile production lines. The technology uses a wire guide to form submicrofibres in a dense, narrow mesh which can be detached as a long and continuous thread. The thread can then be stretched and used to create multifilament yarns which can imitate the hierarchical architecture of tissues such as tendons and ligaments. Electrospun polydioxanone yarns produced by this method showed improved cellular proliferation and adhesion when compared to medical monofilament fibres in current clinical use. In vivo, the electrospun yarns showed a good safety profile with mild foreign body reaction and complete degradation within 5 months after implantation. These results suggest that this filament collection method has the potential to become a useful platform for the fabrication of future medical textiles.
Collapse
Affiliation(s)
- Pierre-Alexis Mouthuy
- Botnar Institute of Musculoskeletal Sciences, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
| | | | | | | | | |
Collapse
|
32
|
Freedman BR, Bade ND, Riggin CN, Zhang S, Haines PG, Ong KL, Janmey PA. The (dys)functional extracellular matrix. BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR CELL RESEARCH 2015; 1853:3153-64. [PMID: 25930943 DOI: 10.1016/j.bbamcr.2015.04.015] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2015] [Revised: 04/11/2015] [Accepted: 04/13/2015] [Indexed: 10/23/2022]
Abstract
The extracellular matrix (ECM) is a major component of the biomechanical environment with which cells interact, and it plays important roles in both normal development and disease progression. Mechanical and biochemical factors alter the biomechanical properties of tissues by driving cellular remodeling of the ECM. This review provides an overview of the structural, compositional, and mechanical properties of the ECM that instruct cell behaviors. Case studies are reviewed that highlight mechanotransduction in the context of two distinct tissues: tendons and the heart. Although these two tissues demonstrate differences in relative cell-ECM composition and mechanical environment, they share similar mechanisms underlying ECM dysfunction and cell mechanotransduction. Together, these topics provide a framework for a fundamental understanding of the ECM and how it may vary across normal and diseased tissues in response to mechanical and biochemical cues. This article is part of a Special Issue entitled: Mechanobiology.
Collapse
Affiliation(s)
- Benjamin R Freedman
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Nathan D Bade
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Corinne N Riggin
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Sijia Zhang
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Philip G Haines
- Division of Cardiovascular Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Katy L Ong
- Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, PA, USA
| | - Paul A Janmey
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA; Department of Physiology, University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|
33
|
Thorpe CT, Godinho MSC, Riley GP, Birch HL, Clegg PD, Screen HRC. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons. J Mech Behav Biomed Mater 2015; 52:85-94. [PMID: 25958330 PMCID: PMC4655227 DOI: 10.1016/j.jmbbm.2015.04.009] [Citation(s) in RCA: 94] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Revised: 02/27/2015] [Accepted: 04/07/2015] [Indexed: 11/23/2022]
Abstract
While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Fascicle sliding enables high levels of extension in energy storing tendons. Sliding mechanics are governed by the interfascicular matrix (IFM). We assessed IFM extension and recovery. IFM elasticity and recovery are greater in energy storing tendons. The IFM plays an important role in the function of energy storing tendons.
Collapse
Affiliation(s)
- Chavaunne T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS UK.
| | - Marta S C Godinho
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS UK
| | - Graham P Riley
- School of Biological Sciences, University of East Anglia, Norwich Research Park, Norwich NR4 7TJ, UK
| | - Helen L Birch
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore HA7 4LP, UK
| | - Peter D Clegg
- Department of Musculoskeletal Biology, Institute of Ageing and Chronic Disease, University of Liverpool, Leahurst Campus, Neston CH64 7TE, UK
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS UK
| |
Collapse
|
34
|
Thorpe CT, Chaudhry S, Lei II, Varone A, Riley GP, Birch HL, Clegg PD, Screen HRC. Tendon overload results in alterations in cell shape and increased markers of inflammation and matrix degradation. Scand J Med Sci Sports 2014; 25:e381-91. [DOI: 10.1111/sms.12333] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/05/2014] [Indexed: 12/22/2022]
Affiliation(s)
- C. T. Thorpe
- Institute of Bioengineering; School of Engineering and Materials Science; Queen Mary University of London; London UK
| | - S. Chaudhry
- Institute of Bioengineering; School of Engineering and Materials Science; Queen Mary University of London; London UK
| | - I. I. Lei
- Institute of Bioengineering; School of Engineering and Materials Science; Queen Mary University of London; London UK
| | - A. Varone
- Institute of Bioengineering; School of Engineering and Materials Science; Queen Mary University of London; London UK
| | - G. P. Riley
- School of Biological Sciences; University of East Anglia; Norwich UK
| | - H. L. Birch
- Institute of Orthopaedics and Musculoskeletal Science; University College London; Stanmore UK
| | - P. D. Clegg
- Department of Musculoskeletal Biology; Institute of Ageing and Chronic Disease; University of Liverpool; Neston UK
| | - H. R. C. Screen
- Institute of Bioengineering; School of Engineering and Materials Science; Queen Mary University of London; London UK
| |
Collapse
|
35
|
Lamas LP, Main RP, Hutchinson JR. Ontogenetic scaling patterns and functional anatomy of the pelvic limb musculature in emus (Dromaius novaehollandiae). PeerJ 2014; 2:e716. [PMID: 25551028 PMCID: PMC4277488 DOI: 10.7717/peerj.716] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2014] [Accepted: 12/10/2014] [Indexed: 11/30/2022] Open
Abstract
Emus (Dromaius novaehollandiae) are exclusively terrestrial, bipedal and cursorial ratites with some similar biomechanical characteristics to humans. Their growth rates are impressive, as their body mass increases eighty-fold from hatching to adulthood whilst maintaining the same mode of locomotion throughout life. These ontogenetic characteristics stimulate biomechanical questions about the strategies that allow emus to cope with their rapid growth and locomotion, which can be partly addressed via scaling (allometric) analysis of morphology. In this study we have collected pelvic limb anatomical data (muscle architecture, tendon length, tendon mass and bone lengths) and calculated muscle physiological cross sectional area (PCSA) and average tendon cross sectional area from emus across three ontogenetic stages (n = 17, body masses from 3.6 to 42 kg). The data were analysed by reduced major axis regression to determine how these biomechanically relevant aspects of morphology scaled with body mass. Muscle mass and PCSA showed a marked trend towards positive allometry (26 and 27 out of 34 muscles respectively) and fascicle length showed a more mixed scaling pattern. The long tendons of the main digital flexors scaled with positive allometry for all characteristics whilst other tendons demonstrated a less clear scaling pattern. Finally, the two longer bones of the limb (tibiotarsus and tarsometatarsus) also exhibited positive allometry for length, and two others (femur and first phalanx of digit III) had trends towards isometry. These results indicate that emus experience a relative increase in their muscle force-generating capacities, as well as potentially increasing the force-sustaining capacities of their tendons, as they grow. Furthermore, we have clarified anatomical descriptions and provided illustrations of the pelvic limb muscle–tendon units in emus.
Collapse
Affiliation(s)
- Luis P Lamas
- Structure and Motion Laboratory, Department of Comparative Biomedical Sciences, The Royal Veterinary College , Hatfield , United Kingdom
| | - Russell P Main
- Department of Basic Medical Sciences, College of Veterinary Medicine, Purdue University , West Lafayette, IN , USA
| | - John R Hutchinson
- Structure and Motion Laboratory, Department of Comparative Biomedical Sciences, The Royal Veterinary College , Hatfield , United Kingdom
| |
Collapse
|
36
|
Szczesny SE, Elliott DM. Incorporating plasticity of the interfibrillar matrix in shear lag models is necessary to replicate the multiscale mechanics of tendon fascicles. J Mech Behav Biomed Mater 2014; 40:325-338. [PMID: 25262202 DOI: 10.1016/j.jmbbm.2014.09.005] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2014] [Revised: 08/26/2014] [Accepted: 09/02/2014] [Indexed: 11/18/2022]
Abstract
Despite current knowledge of tendon structure, the fundamental deformation mechanisms underlying tendon mechanics and failure are unknown. We recently showed that a shear lag model, which explicitly assumed plastic interfibrillar load transfer between discontinuous fibrils, could explain the multiscale fascicle mechanics, suggesting that fascicle yielding is due to plastic deformation of the interfibrillar matrix. However, it is unclear whether alternative physical mechanisms, such as elastic interfibrillar deformation or fibril yielding, also contribute to fascicle mechanical behavior. The objective of the current work was to determine if plasticity of the interfibrillar matrix is uniquely capable of explaining the multiscale mechanics of tendon fascicles including the tissue post-yield behavior. This was examined by comparing the predictions of a continuous fibril model and three separate shear lag models incorporating an elastic, plastic, or elastoplastic interfibrillar matrix with multiscale experimental data. The predicted effects of fibril yielding on each of these models were also considered. The results demonstrated that neither the continuous fibril model nor the elastic shear lag model can successfully predict the experimental data, even if fibril yielding is included. Only the plastic or elastoplastic shear lag models were capable of reproducing the multiscale tendon fascicle mechanics. Differences between these two models were small, although the elastoplastic model did improve the fit of the experimental data at low applied tissue strains. These findings suggest that while interfibrillar elasticity contributes to the initial stress response, plastic deformation of the interfibrillar matrix is responsible for tendon fascicle post-yield behavior. This information sheds light on the physical processes underlying tendon failure, which is essential to improve our understanding of tissue pathology and guide the development of successful repair.
Collapse
Affiliation(s)
- Spencer E Szczesny
- Department of Bioengineering, University of Pennsylvania, 240 Skirkanich Hall, 210 South 33rd St, Philadelphia, PA 19104, United States.
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, 125 East Delaware Avenue, Newark, DE 19716, United States.
| |
Collapse
|
37
|
Fang F, Sawhney AS, Lake SP. Different regions of bovine deep digital flexor tendon exhibit distinct elastic, but not viscous, mechanical properties under both compression and shear loading. J Biomech 2014; 47:2869-77. [DOI: 10.1016/j.jbiomech.2014.07.026] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2014] [Revised: 07/16/2014] [Accepted: 07/22/2014] [Indexed: 11/30/2022]
|
38
|
Shepherd JH, Riley GP, Screen HRC. Early stage fatigue damage occurs in bovine tendon fascicles in the absence of changes in mechanics at either the gross or micro-structural level. J Mech Behav Biomed Mater 2014; 38:163-72. [PMID: 25001495 PMCID: PMC4148183 DOI: 10.1016/j.jmbbm.2014.06.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2014] [Revised: 06/01/2014] [Accepted: 06/04/2014] [Indexed: 12/04/2022]
Abstract
Many tendon injuries are believed to result from repetitive motion or overuse, leading to the accumulation of micro-damage over time. In vitro fatigue loading can be used to characterise damage during repeated use and investigate how this may relate to the aetiology of tendinopathy. This study considered the effect of fatigue loading on fascicles from two functionally distinct bovine tendons: the digital extensor and deep digital flexor. Micro-scale extension mechanisms were investigated in fascicles before or after a period of cyclic creep loading, comparing two different measurement techniques – the displacement of a photo-bleached grid and the use of nuclei as fiducial markers. Whilst visual damage was clearly identified after only 300 cycles of creep loading, these visual changes did not affect either gross fascicle mechanics or fascicle microstructural extension mechanisms over the 900 fatigue cycles investigated. However, significantly greater fibre sliding was measured when observing grid deformation rather than the analysis of nuclei movement. Measurement of microstructural extension with both techniques was localised and this may explain the absence of change in microstructural deformation in response to fatigue loading. Alternatively, the data may demonstrate that fascicles can withstand a degree of matrix disruption with no impact on mechanics. Whilst use of a photo-bleached grid to directly measure the collagen is the best indicator of matrix deformation, nuclei tracking may provide a better measure of the strain perceived directly by the cells. Tendon fascicle gross mechanics and micro-scale deformation investigated after fatigue loading. Fascicles can withstand a degree of matrix disruption without impact on mechanics. More fibre sliding was observed measuring grid deformation than tracking nuclei. Nuclei tracking may better represent the strains experienced by cells than grid deformation.
Collapse
Affiliation(s)
- Jennifer H Shepherd
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, Mile End Road, E1 4NS, UK
| | - Graham P Riley
- School of Biological Sciences, University of East Anglia, UK
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, Mile End Road, E1 4NS, UK.
| |
Collapse
|
39
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HR. Effect of fatigue loading on structure and functional behaviour of fascicles from energy-storing tendons. Acta Biomater 2014; 10:3217-24. [PMID: 24747261 DOI: 10.1016/j.actbio.2014.04.008] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Revised: 03/07/2014] [Accepted: 04/08/2014] [Indexed: 11/26/2022]
Abstract
Tendons can broadly be categorized according to their function: those that act purely to position the limb and those that have an additional function as energy stores. Energy-storing tendons undergo many cycles of large deformations during locomotion, and so must be able to extend and recoil efficiently, rapidly and repeatedly. Our previous work has shown rotation in response to applied strain in fascicles from energy-storing tendons, indicating the presence of helical substructures which may provide greater elasticity and recovery. In the current study, we assessed how preconditioning and fatigue loading affect the ability of fascicles from the energy-storing equine superficial digital flexor tendon to extend and recoil. We hypothesized that preconditioned samples would exhibit changes in microstructural strain response, but would retain their ability to recover. We further hypothesized that fatigue loading would result in sample damage, causing further alterations in extension mechanisms and a significant reduction in sample recovery. The results broadly support these hypotheses: preconditioned samples showed some alterations in microstructural strain response, but were able to recover following the removal of load. However, fatigue loaded samples showed visual evidence of damage and exhibited further alterations in extension mechanisms, characterized by decreased rotation in response to applied strain. This was accompanied by increased hysteresis and decreased recovery. These results suggest that fatigue loading results in a compromised helix substructure, reducing the ability of energy-storing tendons to recoil. A decreased ability to recoil may lead to an impaired response to further loading, potentially increasing the likelihood of injury.
Collapse
|
40
|
Szczesny SE, Edelstein RS, Elliott DM. DTAF dye concentrations commonly used to measure microscale deformations in biological tissues alter tissue mechanics. PLoS One 2014; 9:e99588. [PMID: 24915570 PMCID: PMC4051763 DOI: 10.1371/journal.pone.0099588] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2014] [Accepted: 05/16/2014] [Indexed: 11/18/2022] Open
Abstract
Identification of the deformation mechanisms and specific components underlying the mechanical function of biological tissues requires mechanical testing at multiple levels within the tissue hierarchical structure. Dichlorotriazinylaminofluorescein (DTAF) is a fluorescent dye that is used to visualize microscale deformations of the extracellular matrix in soft collagenous tissues. However, the DTAF concentrations commonly employed in previous multiscale experiments (≥2000 µg/ml) may alter tissue mechanics. The objective of this study was to determine whether DTAF affects tendon fascicle mechanics and if a concentration threshold exists below which any observed effects are negligible. This information is valuable for guiding the continued use of this fluorescent dye in future experiments and for interpreting the results of previous work. Incremental strain testing demonstrated that high DTAF concentrations (≥100 µg/ml) increase the quasi-static modulus and yield strength of rat tail tendon fascicles while reducing their viscoelastic behavior. Subsequent multiscale testing and modeling suggests that these effects are due to a stiffening of the collagen fibrils and strengthening of the interfibrillar matrix. Despite these changes in tissue behavior, the fundamental deformation mechanisms underlying fascicle mechanics appear to remain intact, which suggests that conclusions from previous multiscale investigations of strain transfer are still valid. The effects of lower DTAF concentrations (≤10 µg/ml) on tendon mechanics were substantially smaller and potentially negligible; nevertheless, no concentration was found that did not at least slightly alter the tissue behavior. Therefore, future studies should either reduce DTAF concentrations as much as possible or use other dyes/techniques for measuring microscale deformations.
Collapse
Affiliation(s)
- Spencer E. Szczesny
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Rachel S. Edelstein
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware, United States of America
| | - Dawn M. Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware, United States of America
| |
Collapse
|