1
|
Imran KM, Gannon J, Morrison HA, Tupik JD, Tintera B, Nagai-Singer MA, Ivester H, Madanick JM, Hendricks-Wenger A, Uh K, Luyimbazi DT, Edwards M, Coutermarsh-Ott S, Eden K, Byron C, Clark-Deener S, Lee K, Vlaisavljevich E, Allen IC. Successful In Situ Targeting of Pancreatic Tumors in a Novel Orthotopic Porcine Model Using Histotripsy. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:2361-2370. [PMID: 37596154 PMCID: PMC10529075 DOI: 10.1016/j.ultrasmedbio.2023.07.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 07/26/2023] [Accepted: 07/28/2023] [Indexed: 08/20/2023]
Abstract
OBJECTIVE New therapeutic strategies and paradigms are direly needed to treat pancreatic cancer. The absence of a suitable pre-clinical animal model of pancreatic cancer is a major limitation to biomedical device and therapeutic development. Traditionally, pigs have proven to be ideal models, especially in the context of designing human-sized instruments, perfecting surgical techniques and optimizing clinical procedures for use in humans. However, pig studies have typically focused on healthy tissue assessments and are limited to general safety evaluations because of the inability to effectively model human tumors. METHODS Here, we establish an orthotopic porcine model of human pancreatic cancer using RAG2/IL2RG double-knockout immunocompromised pigs and treat the tumors ex vivo and in vivo with histotripsy. RESULTS Using these animals, we describe the successful engraftment of Panc-1 human pancreatic cancer cell line tumors and characterize their development. To illustrate the utility of these animals for therapeutic development, we determine for the first time, the successful targeting of in situ pancreatic tumors using histotripsy. Treatment with histotripsy resulted in partial ablation in vivo and reduction in collagen content in both in vivo tumor in pig pancreas and ex vivo patient tumor. CONCLUSION This study presents a first step toward establishing histotripsy as a non-invasive treatment method for pancreatic cancer and exposes some of the challenges of ultrasound guidance for histotripsy ablation in the pancreas. Simultaneously, we introduce a highly robust model of pancreatic cancer in a large mammal model that could be used to evaluate a variety biomedical devices and therapeutic strategies.
Collapse
Affiliation(s)
- Khan Mohammad Imran
- Graduate Program in Translational Biology, Medicine and Health, Virginia Polytechnic Institute and State University, Roanoke, VA, USA; Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Jessica Gannon
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
| | - Holly A Morrison
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Juselyn D Tupik
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Benjamin Tintera
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA; Virginia Tech Carilion School of Medicine, Roanoke, VA, USA
| | - Margaret A Nagai-Singer
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Hannah Ivester
- Graduate Program in Translational Biology, Medicine and Health, Virginia Polytechnic Institute and State University, Roanoke, VA, USA; Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Justin Markov Madanick
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Alissa Hendricks-Wenger
- Graduate Program in Translational Biology, Medicine and Health, Virginia Polytechnic Institute and State University, Roanoke, VA, USA; Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA; Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA; DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Knoxville, TN, USA
| | - Kyungjun Uh
- Division of Animal Science, College of Agriculture Food and Natural Resources, University of Missouri, Columbia, MO, USA
| | - David T Luyimbazi
- Department of Surgery, Carilion Clinic and Virginia Tech Carilion School of Medicine, Roanoke, VA, USA
| | - Michael Edwards
- Department of Small Animal Clinical Sciences, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Sheryl Coutermarsh-Ott
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Kristin Eden
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Christopher Byron
- Department of Large Animal Clinical Sciences, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Sherrie Clark-Deener
- Department of Large Animal Clinical Sciences, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA
| | - Kiho Lee
- Division of Animal Science, College of Agriculture Food and Natural Resources, University of Missouri, Columbia, MO, USA
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
| | - Irving C Allen
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Blacksburg, VA, USA.
| |
Collapse
|
2
|
Koukas E, Papoutsakis A, Gavaises M. Numerical investigation of shock-induced bubble collapse dynamics and fluid-solid interactions during shock-wave lithotripsy. ULTRASONICS SONOCHEMISTRY 2023; 95:106393. [PMID: 37031534 PMCID: PMC10114246 DOI: 10.1016/j.ultsonch.2023.106393] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 03/14/2023] [Accepted: 03/28/2023] [Indexed: 06/19/2023]
Abstract
In this paper we investigate the bubble collapse dynamics under shock-induced loading near soft and rigid bio-materials, during shock wave lithotripsy. A novel numerical framework was developed, that employs a Diffuse Interface Method (DIM) accounting for the interaction across fluid-solid-gas interfaces. For the resolution of the extended variety of length scales, due to the dynamic and fine interfacial structures, an Adaptive Mesh Refinement (AMR) framework for unstructured grids was incorporated. This multi-material multi-scale approach aims to reduce the numerical diffusion and preserve sharp interfaces. The presented numerical framework is validated for cases of bubble dynamics, under high and low ambient pressure ratios, shock-induced collapses, and wave transmission problems across a fluid-solid interface, against theoretical and numerical results. Three different configurations of shock-induced collapse applications near a kidney stone and soft tissue have been simulated for different stand-off distances and bubble attachment configurations. The obtained results reveal the detailed collapse dynamics, jet formation, solid deformation, rebound, primary and secondary shock wave emissions, and secondary collapse that govern the near-solid collapse and penetration mechanisms. Significant correlations of the problem configuration to the overall collapse mechanisms were found, stemming from the contact angle/attachment of the bubble and from the properties of solid material. In general, bubbles with their center closer to the kidney stone surface produce more violent collapses. For the soft tissue, the bubble movement prior to the collapse is of great importance as new structures can emerge which can trap the liquid jet into induced crevices. Finally, the tissue penetration is examined for these cases and a novel tension-driven tissue injury mechanism is elucidated, emanating from the complex interaction of the bubble/tissue interaction during the secondary collapse phase of an entrapped bubble in an induced crevice with the liquid jet.
Collapse
Affiliation(s)
- Evangelos Koukas
- Department of Mechanical Engineering and Aeronautics, School of Mathematics, Computer Science and Engineering, City University of London, Northampton Square, EC1V 0HB London, UK.
| | - Andreas Papoutsakis
- Department of Engineering, School of Physics Engineering and Computer Science (SPECS), University of Hertfordshire, College Lane Campus, AL10 9AB Hatfield, UK
| | - Manolis Gavaises
- Department of Mechanical Engineering and Aeronautics, School of Mathematics, Computer Science and Engineering, City University of London, Northampton Square, EC1V 0HB London, UK
| |
Collapse
|
3
|
Imran KM, Ganguly A, Paul T, Powar M, Vlaisavljevich E, Cho CS, Allen IC. Magic bubbles: utilizing histotripsy to modulate the tumor microenvironment and improve systemic anti-tumor immune responses. Int J Hyperthermia 2023; 40:2244206. [PMID: 37580047 PMCID: PMC10430775 DOI: 10.1080/02656736.2023.2244206] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 07/28/2023] [Accepted: 07/29/2023] [Indexed: 08/16/2023] Open
Abstract
Focused Ultrasound (FUS) is emerging as a promising primary and adjunct therapy for the treatment of cancer. This includes histotripsy, which is a noninvasive, non-ionizing, non-thermal ultrasound guided ablation modality. As histotripsy has progressed from bench-to-bedside, it has become evident that this therapy has benefits beyond local tumor ablation. Specifically, histotripsy has the potential to shift the local tumor microenvironment from immunologically 'cold' to 'hot'. This is associated with the production of damage associated molecular patterns, the release of a selection of proinflammatory mediators, and the induction of inflammatory forms of cell death in cells just outside of the treatment zone. In addition to the induction of this innate immune response, histotripsy can also improve engagement of the adaptive immune system and promote systemic anti-tumor immunity targeting distal tumors and metastatic lesions. These tantalizing observations suggest that, in settings of widely metastatic disease burden, selective histotripsy of a limited number of accessible tumors could be a means of maximizing responsiveness to systemic immunotherapy. More work is certainly needed to optimize treatment strategies that best synergize histotripsy parameters with innate and adaptive immune responses. Likewise, rigorous clinical studies are still necessary to verify the presence and repeatability of these phenomena in human patients. As this technology nears regulatory approval for clinical use, it is our expectation that the insights and immunomodulatory mechanisms summarized in this review will serve as directional guides for rational clinical studies to validate and optimize the potential immunotherapeutic role of histotripsy tumor ablation.
Collapse
Affiliation(s)
- Khan M. Imran
- Graduate Program in Translational Biology, Medicine and Health, Virginia Tech, Roanoke, VA, USA
| | - Anutosh Ganguly
- Department of Surgery, University of Michigan Medical School, Ann Arbor, MI, USA
| | - Tamalika Paul
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Virginia Tech, Blacksburg, VA, USA
| | - Manali Powar
- Graduate Program in Translational Biology, Medicine and Health, Virginia Tech, Roanoke, VA, USA
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA, USA
- Institute for Critical and Applied Science Center for Engineered Health, Virginia Tech, Blacksburg, VA, USA
| | - Clifford S. Cho
- Department of Surgery, University of Michigan Medical School, Ann Arbor, MI, USA
- Research Service, Ann Arbor VA Healthcare, Ann Arbor, MI, USA
| | - Irving C. Allen
- Graduate Program in Translational Biology, Medicine and Health, Virginia Tech, Roanoke, VA, USA
- Department of Biomedical Sciences and Pathobiology, Virginia-Maryland College of Veterinary Medicine, Virginia Tech, Blacksburg, VA, USA
- Institute for Critical and Applied Science Center for Engineered Health, Virginia Tech, Blacksburg, VA, USA
- Virginia Tech Carilion School of Medicine, Roanoke, VA, USA
| |
Collapse
|
4
|
de Andrade MO, Haqshenas R, Pahk KJ, Saffari N. Mechanisms of nuclei growth in ultrasound bubble nucleation. ULTRASONICS SONOCHEMISTRY 2022; 88:106091. [PMID: 35839705 PMCID: PMC9287806 DOI: 10.1016/j.ultsonch.2022.106091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 06/20/2022] [Accepted: 07/04/2022] [Indexed: 06/15/2023]
Abstract
This paper interrogates the intersections between bubble dynamics and classical nucleation theory (CNT) towards constructing a model that describes intermediary nucleation events between the extrema of cavitation and boiling. We employ Zeldovich's hydrodynamic approach to obtain a description of bubble nuclei that grow simultaneously via hydrodynamic excitation by the acoustic field and vapour transport. By quantifying the relative dominance of both mechanisms, it is then possible to discern the extent to which viscosity, inertia, surface tension and vapour transport shape the growth of bubble nuclei through non-dimensional numbers that naturally arise within the theory. The first non-dimensional number Φ12/Φ2 is analogous to the Laplace number, representing the balance between surface tension and inertial constraints to viscous effects. The second non-dimensional number δ represents how enthalpy transport into the bubble can reduce nucleation rates by cooling the surrounding liquid. This formulation adds to the current understanding of ultrasound bubble nucleation by accounting for bubble dynamics during nucleation, quantifying the physical distinctions between "boiling" and "cavitation" bubbles through non-dimensional parameters, and outlining the characteristic timescales of nucleation according to the growth mechanism of bubbles throughout the histotripsy temperature range. We observed in our simulations that viscous effects control the process of ultrasound nucleation in water-like media throughout the 0-120 °C temperature range, although this dominance decreases with increasing temperatures. Enthalpy transport was found to reduce nucleation rates for increasing temperatures. This effect becomes significant at temperatures above 30 °C and favours the creation of fewer nuclei that are larger in size. Conversely, negligible enthalpy transport at lower temperatures can enable the nucleation of dense clusters of small nuclei, such as cavitation clouds. We find that nuclei growth as modelled by the Rayleigh-Plesset equation occurs over shorter timescales than as modelled by vapour-dominated growth. This suggests that the first stage of bubble nuclei growth is hydrodynamic, and vapour transport effects can only be observed over longer timescales. Finally, we propose that this framework can be used for comparison between different experiments in bubble nucleation, towards standardisation and dosimetry of protocols.
Collapse
Affiliation(s)
| | - Reza Haqshenas
- UCL Mechanical Engineering, University College London, London, United Kingdom
| | - Ki Joo Pahk
- Department of Biomedical Engineering, Kyung Hee University, Yongin, Republic of Korea
| | - Nader Saffari
- UCL Mechanical Engineering, University College London, London, United Kingdom
| |
Collapse
|
5
|
Braunstein L, Brüningk SC, Rivens I, Civale J, Haar GT. Characterization of Acoustic, Cavitation, and Thermal Properties of Poly(vinyl alcohol) Hydrogels for Use as Therapeutic Ultrasound Tissue Mimics. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1095-1109. [PMID: 35337687 DOI: 10.1016/j.ultrasmedbio.2022.02.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 01/19/2022] [Accepted: 02/06/2022] [Indexed: 06/14/2023]
Abstract
The thermal and mechanical effects induced in tissue by ultrasound can be exploited for therapeutic applications. Tissue-mimicking materials (TMMs), reflecting different soft tissue properties, are required for experimental evaluation of therapeutic potential. In the study described here, poly(vinyl alcohol) (PVA) hydrogels were characterized. Hydrogels prepared using different concentrations (5%-20% w/w) and molecular weights of PVA ± cellulose scatterers (2.5%-10% w/w) were characterized acoustically (sound speed, attenuation) as a function of temperature (25°C-45°C), thermally (thermal conductivity, specific heat capacity) and in terms of their cavitation thresholds. Results were compared with measurements in fresh sheep tissue (kidney, liver, spleen). Sound speed depended most strongly on PVA concentration, and attenuation, on cellulose content. For the range of formulations investigated, the PVA gel acoustic properties (sound speed: 1532 ± 17 to 1590 ± 9 m/s, attenuation coefficient: 0.08 ± 0.01 to 0.37 ± 0.02 dB/cm) fell within those measured in fresh tissue. Cavitation thresholds for 10% PVA hydrogels (50% occurrence: 4.1-5.4 MPa, 75% occurrence: 5.4-8.2 MPa) decreased with increasing cellulose content. In summary, PVA cellulose composite hydrogels may be suitable mimics of acoustic, cavitation and thermal properties of soft tissue for a number of therapeutic ultrasound applications.
Collapse
Affiliation(s)
- Lisa Braunstein
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom.
| | - Sarah C Brüningk
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom; Machine Learning & Computational Biology Lab, Department of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland; SIB Swiss Institute of Bioinformatics, Lausanne, Switzerland
| | - Ian Rivens
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - John Civale
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Gail Ter Haar
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
6
|
Jeong MK, Choi MJ, Kwon SJ. High-spatial-resolution, instantaneous passive cavitation imaging with temporal resolution in histotripsy: a simulation study. Ultrasonography 2022; 41:566-577. [PMID: 35535468 PMCID: PMC9262664 DOI: 10.14366/usg.21153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 02/22/2022] [Indexed: 11/08/2022] Open
Abstract
Purpose In histotripsy, a shock wave is transmitted, and the resulting inertial bubble cavitation that disrupts tissue is used for treatment. Therefore, it is necessary to detect when cavitation occurs and track the position of cavitation occurrence using a new passive cavitation (PC) imaging method. Methods An integrated PC image, which is constructed by collecting the focused signals at all times, does not provide information on when cavitation occurs and has poor spatial resolution. To solve this problem, we constructed instantaneous PC images by applying delay and sum beamforming at instantaneous time instants. By calculating instantaneous PC images at all data acquisition times, the proposed method can detect cavitation when it occurs by using the property that when signals from the cavitation are focused, their amplitude becomes large, and it can obtain a high-resolution PC image by masking out side lobes in the vicinity of cavitation. Results Ultrasound image simulation confirmed that the proposed method has higher resolution than conventional integrated PC imaging and showed that it can determine the position and time of cavitation occurrence as well as the signal strength. Conclusion Since the proposed novel PC imaging method can detect each cavitation separately when the incidence of cavitations is low, it can be used to monitor the treatment process of shock wave therapy and histotripsy, in which cavitation is an important mechanism of treatment.
Collapse
Affiliation(s)
- Mok Kun Jeong
- Department of Electronic Engineering, Daejin University, Pocheon, Korea
| | - Min Joo Choi
- Department of Medicine, Jeju National University, Jeju, Korea
| | - Sung Jae Kwon
- Division of IT Convergence Engineering, Daejin University, Pocheon, Korea
| |
Collapse
|
7
|
Spratt JS, Rodriguez M, Schmidmayer K, Bryngelson SH, Yang J, Franck C, Colonius T. Characterizing viscoelastic materials via ensemble-based data assimilation of bubble collapse observations. JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS 2021; 152:104455. [PMID: 34092810 PMCID: PMC8177475 DOI: 10.1016/j.jmps.2021.104455] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Viscoelastic material properties at high strain rates are needed to model many biological and medical systems. Bubble cavitation can induce such strain rates, and the resulting bubble dynamics are sensitive to the material properties. Thus, in principle, these properties can be inferred via measurements of the bubble dynamics. Estrada et al. (2018) demonstrated such bubble-dynamic high-strain-rate rheometry by using least-squares shooting to minimize the difference between simulated and experimental bubble radius histories. We generalize their technique to account for additional uncertainties in the model, initial conditions, and material properties needed to uniquely simulate the bubble dynamics. Ensemble-based data assimilation minimizes the computational expense associated with the bubble cavitation model, providing a more efficient and scalable numerical framework for bubble-collapse rheometry. We test an ensemble Kalman filter (EnKF), an iterative ensemble Kalman smoother (IEnKS), and a hybrid ensemble-based 4D-Var method (En4D-Var) on synthetic data, assessing their estimations of the viscosity and shear modulus of a Kelvin-Voigt material. Results show that En4D-Var and IEnKS provide better moduli estimates than EnKF. Applying these methods to the experimental data of Estrada et al. (2018) yields similar material property estimates to those they obtained, but provides additional information about uncertainties. In particular, the En4D-Var yields lower viscosity estimates for some experiments, and the dynamic estimators reveal a potential mechanism that is unaccounted for in the model, whereby the apparent viscosity is reduced in some cases due to inelastic behavior, possibly in the form of material damage occurring at bubble collapse.
Collapse
Affiliation(s)
- Jean-Sebastien Spratt
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA 91125, USA
| | - Mauro Rodriguez
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA 91125, USA
| | - Kevin Schmidmayer
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA 91125, USA
| | - Spencer H. Bryngelson
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA 91125, USA
| | - Jin Yang
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Christian Franck
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Tim Colonius
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA 91125, USA
| |
Collapse
|
8
|
Jiang Z, Dickinson RJ, Hall TL, Choi JJ. A PZT-PVDF Stacked Transducer for Short-Pulse Ultrasound Therapy and Monitoring. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2164-2171. [PMID: 33591915 DOI: 10.1109/tuffc.2021.3059715] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Therapeutic ultrasound technologies using microbubbles require a feedback control system to perform the treatment in a safe and effective manner. Current feedback control technologies utilize the microbubble's acoustic emissions to adjust the treatment acoustic parameters. Typical systems use two separated transducers: one for transmission and the other for reception. However, separating the transmitter and receiver leads to foci misalignment. This limitation could be resolved by arranging the transmitter and receiver in a stacked configuration. Taking advantage of an increasing number of short-pulse-based therapeutic methods, we have constructed a lead zirconate titanate-polyvinylidene fluoride (PZT-PVDF) stacked transducer design that allows the transmission and reception of short-pulse ultrasound from the same location. Our design had a piston transmitter composed of a PZT disk (1 MHz, 12.7 mm in diameter), a backing layer, and two matching layers. A layer of PVDF ( [Formula: see text] in thickness, 12.7 mm in diameter) was placed at the front surface of the transmitter for reception. Transmission and reception from the same location were demonstrated in pulse-echo experiments where PZT transmitted a pulse and both PZT and PVDF received the echo. The echo signal received by the PVDF was [Formula: see text] shorter than the signal received by the PZT. Reception of broadband acoustic emissions using the PVDF was also demonstrated in experiments where microbubbles were exposed to ultrasound pulses. Thus, we have shown that our PZT-PVDF stack design has unique transmission and reception features that could be incorporated into a multielement array design that improves focal superimposing, transmission efficiency, and reception sensitivity.
Collapse
|
9
|
Edsall C, Khan ZM, Mancia L, Hall S, Mustafa W, Johnsen E, Klibanov AL, Durmaz YY, Vlaisavljevich E. Bubble Cloud Behavior and Ablation Capacity for Histotripsy Generated from Intrinsic or Artificial Cavitation Nuclei. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:620-639. [PMID: 33309443 PMCID: PMC8514340 DOI: 10.1016/j.ultrasmedbio.2020.10.020] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2020] [Revised: 10/26/2020] [Accepted: 10/28/2020] [Indexed: 05/04/2023]
Abstract
The study described here examined the effects of cavitation nuclei characteristics on histotripsy. High-speed optical imaging was used to compare bubble cloud behavior and ablation capacity for histotripsy generated from intrinsic and artificial cavitation nuclei (gas-filled microbubbles, fluid-filled nanocones). Results showed a significant decrease in the cavitation threshold for microbubbles and nanocones compared with intrinsic-nuclei controls, with predictable and well-defined bubble clouds generated in all cases. Red blood cell experiments showed complete ablations for intrinsic and nanocone phantoms, but only partial ablation in microbubble phantoms. Results also revealed a lower rate of ablation in artificial-nuclei phantoms because of reduced bubble expansion (and corresponding decreases in stress and strain). Overall, this study demonstrates the potential of using artificial nuclei to reduce the histotripsy cavitation threshold while highlighting differences in the bubble cloud behavior and ablation capacity that need to be considered in the future development of these approaches.
Collapse
Affiliation(s)
- Connor Edsall
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA.
| | - Zerin Mahzabin Khan
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Lauren Mancia
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Sarah Hall
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Waleed Mustafa
- Department of Biomedical Engineering, Istanbul Medipol University, Beykoz/İstanbul, Turkey
| | - Eric Johnsen
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Alexander L Klibanov
- Cardiovascular Division, Department of Medicine, University of Virginia, Charlottesville, Virginia
| | - Yasemin Yuksel Durmaz
- Department of Biomedical Engineering, Istanbul Medipol University, Beykoz/İstanbul, Turkey; Regenerative and Restorative Medicine Research Center (REMER), Istanbul Medipol University, Beykoz/İstanbul, Turkey
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA; ICTAS Center for Engineered Health, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
| |
Collapse
|
10
|
Montoya Mira J, Wu L, Sabuncu S, Sapre A, Civitci F, Ibsen S, Esener S, Yildirim A. Gas-Stabilizing Sub-100 nm Mesoporous Silica Nanoparticles for Ultrasound Theranostics. ACS OMEGA 2020; 5:24762-24772. [PMID: 33015494 PMCID: PMC7528327 DOI: 10.1021/acsomega.0c03377] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 08/28/2020] [Indexed: 05/22/2023]
Abstract
Recent studies have demonstrated that gas-stabilizing particles can generate cavitating micron-sized bubbles when exposed to ultrasound, offering excellent application potential, including ultrasound imaging, drug delivery, and tumor ablation. However, the majority of the reported gas-stabilizing particles are relatively large (>200 nm), and smaller particles require high acoustic pressures to promote cavitation. Here, this paper reports the preparation of sub-100 nm gas-stabilizing nanoparticles (GSNs) that can initiate cavitation at low acoustic intensities, which can be delivered using a conventional medical ultrasound imaging system. The highly echogenic GSNs (F127-hMSN) were prepared by carefully engineering the surfaces of ∼50 nm mesoporous silica nanoparticles. It was demonstrated that the F127-hMSNs could be continuously imaged with ultrasound in buffer or biological solutions or agarose phantoms for up to 20 min. Also, the F127-hMSN can be stored in phosphate-buffered saline for at least a month with no loss in ultrasound responsiveness. The particles significantly degraded when diluted in simulated body fluids, indicating possible biodegradation of the F127-hMSNs in vivo. Furthermore, at ultrasound imaging conditions, F127-hMSNs did not cause detectable cell death, supporting the potential safety of these particles. Finally, strong cavitation activity generation by the F127-hMSNs under high-intensity focused ultrasound insonation was demonstrated and applied to effectively ablate cancer cells.
Collapse
Affiliation(s)
- Jose Montoya Mira
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
- Biomedical Engineering, School of Medicine, Oregon Health and Science University, Portland, Oregon 97239, United States
| | - Lucy Wu
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
| | - Sinan Sabuncu
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
| | - Ajay Sapre
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
| | - Fehmi Civitci
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
| | - Stuart Ibsen
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
- Biomedical Engineering, School of Medicine, Oregon Health and Science University, Portland, Oregon 97239, United States
| | - Sadik Esener
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
- Biomedical Engineering, School of Medicine, Oregon Health and Science University, Portland, Oregon 97239, United States
| | - Adem Yildirim
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
| |
Collapse
|
11
|
Rathod VT. A Review of Acoustic Impedance Matching Techniques for Piezoelectric Sensors and Transducers. SENSORS (BASEL, SWITZERLAND) 2020; 20:E4051. [PMID: 32708159 PMCID: PMC7411934 DOI: 10.3390/s20144051] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 07/06/2020] [Accepted: 07/16/2020] [Indexed: 01/28/2023]
Abstract
The coupling of waves between the piezoelectric generators, detectors, and propagating media is challenging due to mismatch in the acoustic properties. The mismatch leads to the reverberation of waves within the transducer, heating, low signal-to-noise ratio, and signal distortion. Acoustic impedance matching increases the coupling largely. This article presents standard methods to match the acoustic impedance of the piezoelectric sensors, actuators, and transducers with the surrounding wave propagation media. Acoustic matching methods utilizing active and passive materials have been discussed. Special materials such as nanocomposites, metamaterials, and metasurfaces as emerging materials have been presented. Emphasis is placed throughout the article to differentiate the difference between electric and acoustic impedance matching and the relation between the two. Comparison of various techniques is made with the discussion on capabilities, advantages, and disadvantages. Acoustic impedance matching for specific and uncommon applications has also been covered.
Collapse
Affiliation(s)
- Vivek T Rathod
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA
| |
Collapse
|
12
|
Burks SR, Lorsung RM, Nagle ME, Tu TW, Frank JA. Focused ultrasound activates voltage-gated calcium channels through depolarizing TRPC1 sodium currents in kidney and skeletal muscle. Theranostics 2019; 9:5517-5531. [PMID: 31534500 PMCID: PMC6735402 DOI: 10.7150/thno.33876] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Accepted: 05/09/2019] [Indexed: 12/26/2022] Open
Abstract
Pulsed focused ultrasound (pFUS) technology is being developed for clinical neuro/immune modulation and regenerative medicine. Biological signal transduction of pFUS forces can require mechanosensitive or voltage-gated plasma membrane ion channels. Previous studies suggested pFUS is capable of activating either channel type, but their mechanistic relationship remains ambiguous. We demonstrated pFUS bioeffects increased mesenchymal stem cell tropism (MSC) by altering molecular microenvironments through cyclooxygenase-2 (COX2)-dependent pathways. This study explored specific relationships between mechanosensitive and voltage-gated Ca2+ channels (VGCC) to initiate pFUS bioeffects that increase stem cell tropism. Methods: Murine kidneys and hamstring were given pFUS (1.15 or 1.125 MHz; 4MPa peak rarefactional pressure) under ultrasound or magnetic resonance imaging guidance. Cavitation and tissue displacement were measure by hydrophone and ultrasound radiofrequency data, respectively. Elastic modeling was performed from displacement measurements. COX2 expression and MSC tropism were evaluated in the presence of pharmacological ion channel inhibitors or in transient-receptor-potential-channel-1 (TRPC1)-deficient mice. Immunohistochemistry and co-immunoprecipitation examined physical channel relationships. Fluorescent ionophore imaging of cultured C2C12 muscle cells or TCMK1 kidney cells probed physiological interactions. Results: pFUS induced tissue deformations resulting in kPa-scale forces suggesting mechanical activation of pFUS-induced bioeffects. Inhibiting VGCC or TRPC1 in vivo blocked pFUS-induced COX2 upregulation and MSC tropism to kidneys and muscle. A TRPC1/VGCC complex was observed in plasma membranes. VGCC or TRPC1 suppression blocked pFUS-induced Ca2+ transients in TCMK1 and C2C12 cells. Additionally, Ca2+ transients were blocked by reducing transmembrane Na+ potentials and observed Na+ transients were diminished by genetic TRPC1 suppression. Conclusion: This study suggests that pFUS acoustic radiation forces mechanically activate a Na+-containing TRPC1 current upstream of VGCC rather than directly opening VGCC. The electrogenic function of TRPC1 provides potential mechanistic insight into other pFUS techniques for physiological modulation and optimization strategies for clinical implementation.
Collapse
|
13
|
Li Y, Hall TL, Xu Z, Cain CA. Enhanced Shock Scattering Histotripsy With Pseudomonopolar Ultrasound Pulses. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:1185-1197. [PMID: 30990430 PMCID: PMC6659739 DOI: 10.1109/tuffc.2019.2911289] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Shock scattering histotripsy involves a complex interaction between positive and negative phases of an acoustic burst to initiate a robust cavitation bubble cloud. To more precisely study these effects and optimize shock scattering histotripsy therapy, we constructed a frequency compounding transducer to generate pseudomonopolar ultrasound pulses. The transducer consisted of 113 individual piezoelectric elements with various resonant frequencies (250 kHz, 500 kHz, 750 kHz, 1 MHz, 1.5 MHz, 2 MHz, and 3 MHz). For each resonant frequency, an extremely short pulse could be generated. Pseudomonopolar peak positive pulses were generated by aligning the principal peak positive pressures of individual frequency components temporally, so that they added constructively, and destructive interference occurred outside the peak-positive-overlapped temporal window. After inverting the polarity of the excitation signals, pseudomonopolar peak negative pulses were generated similarly by aligning principal peak negative pressures. Decoupling the positive and negative acoustic phases could have significant advantages for therapeutic applications enhancing precision and avoiding cavitation at tissue interfaces by using mostly positive pressure pulses. For example, we show that 16 shock scattering bubble clouds can be generated using only peak positive pulses following a single peak negative pulse that initiates a pressure release "seed cloud" from which the first shock front is "scattered." Subsequent positive only pulses result in a precise elongated lesion within red blood cell phantoms.
Collapse
|
14
|
Berlinda Law SK, Zhou Y. High-Intensity Focused Ultrasound Ablation by the Dual-Frequency Excitation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:18-25. [PMID: 30334792 DOI: 10.1109/tuffc.2018.2876331] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
High-intensity focused ultrasound (HIFU) has emerged as an effective and noninvasive therapeutic modality for cancer and solid tumor. Despite its promising clinical outcomes and the approval of the Food and Drug Administration of many countries, the ablation time of a large target is long, so enhancement of the lesion production is highly desired. In this study, dual-frequency (or amplitude modulation) excitation was evaluated both numerically and experimentally, and its performance was compared with that using single-frequency excitation at the same power output. The nonlinear wave propagation model was used to simulate the acoustic field of HIFU exposure, the Gilmore model was used to determine the induced bubble dynamics, and then absorbed acoustic energy and bubble-enhanced heating were put into the BioHeat equation to calculate the temperature elevation. HIFU-produced lesion in the bovine serum albumin-embedded polyacrylamide was recorded photographically. It is found that dual-frequency excitation (3.16 + 3.20MHz) can increase the lesion area by 35%-65% compared to single-frequency excitation (3.18 MHz) at the same power output. The lesion enhancement increases with the pulse repetition frequency, duty cycle, and modulation depth and decreases with the frequency difference. In summary, dual-frequency excitation can increase the bubble cavitation and the associated heating for HIFU ablation for large lesion production.
Collapse
|
15
|
Suarez Escudero D, Goudot G, Vion M, Tanter M, Pernot M. 2D and 3D real-time passive cavitation imaging of pulsed cavitation ultrasound therapy in moving tissues. Phys Med Biol 2018; 63:235028. [PMID: 30520419 DOI: 10.1088/1361-6560/aaef68] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Pulsed cavitation ultrasound therapy (PCUT) is an effective non-invasive therapeutic approach in various medical indications that relies on the mechanical effects generated by cavitation bubbles. Even though limited by the poor contrast, conventional ultrasound B-Mode imaging has been widely used for the guidance and monitoring of the therapeutic procedure, allowing the visualization of the cavitation bubble cloud. However, the visualization of the bubble cloud is often limited in deep organs such as the liver and the heart and remains moreover completely subjective for the operator. Our goal is to develop a new imaging mode to better identify the cavitation cloud. Active and passive cavitation imaging methods have been developed but none of them has been able to locate the cavitation bubble created by PCUT in real-time and in moving organs. In this paper we propose a passive ultrasound imaging approach combined with a spatiotemporal singular value decomposition filter to detect and map the bubble cloud with high sensitivity and high contrast. In moving applications at a maximal motion speed of 10 mm s-1, the contrast-to-noise ratio for passive cavitation imaging is up to 10 times higher than for active cavitation imaging, with a temporal resolution of about 100 ms. The mapping of the bubble cloud can be overlaid in real-time to the conventional B-Mode, which permits to locate the cavitation phenomena in relation to the anatomic image. Finally, we extend the technique to volumetric imaging and show its feasibility on moving phantoms.
Collapse
Affiliation(s)
- Daniel Suarez Escudero
- Institut Langevin, ESPCI ParisTech, CNRS UMR 7587, INSERM U979, Paris 7, 17 rue Moreau, 75012 Paris, France. Cardiawave SA, 29 rue du Faubourg Saint Jacques, 75014, Paris, France
| | | | | | | | | |
Collapse
|
16
|
Yildirim A, Shi D, Roy S, Blum NT, Chattaraj R, Cha JN, Goodwin AP. Nanoparticle-Mediated Acoustic Cavitation Enables High Intensity Focused Ultrasound Ablation Without Tissue Heating. ACS APPLIED MATERIALS & INTERFACES 2018; 10:36786-36795. [PMID: 30339360 PMCID: PMC6702128 DOI: 10.1021/acsami.8b15368] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
While thermal ablation of various solid tumors has been demonstrated using high intensity focused ultrasound (HIFU), the therapeutic outcomes of this technique are still unsatisfactory because of common recurrence of thermally ablated cancers and treatment side effects due to the high ultrasound intensity and acoustic pressure requirements. More precise ablation of tumors can be achieved by generating cavitating bubbles in the tissue using shorter pulses with higher acoustic pressures, which induce mechanical damage rather than thermal. However, it has remained as a challenge to safely deliver the acoustic pressures required for mechanical ablation of solid tumors. Here, we report a method to achieve mechanical ablation at lower acoustic pressures by utilizing phospholipid-stabilized hydrophobic mesoporous silica nanoparticles (PL-hMSN). The PL-hMSNs act as seeds for nucleation of cavitation events and thus significantly reduce the peak negative pressures and spatial-average temporal-average HIFU intensities needed to achieve mechanical ablation. Substantial mechanical damage was observed in the red blood cell or tumor spheroid containing tissue mimicking phantoms at PL-hMSN concentrations as low as 10 μg mL-1, after only 5 s of HIFU treatment with peak negative pressures ∼11 MPa and duty cycles ∼0.01%. Even the application of HIFU (peak negative pressure of 16.8 MPa and duty cycle of 0.017%) for 1 min in the presence of PL-hMSN (200 μg mL-1) did not cause any detectable temperature increase in tissue-mimicking phantoms. In addition, the mechanical effects of cavitation promoted by PL-hMSNs were observed up to 0.5 mm from the center of the cavitation events. This method may thus also improve delivery of therapeutics or nanoparticles to tumor environments with limited macromolecular transport.
Collapse
Affiliation(s)
- Adem Yildirim
- Department of Chemical and Biological Engineering, University of Colorado Boulder. Boulder, Colorado 80303, United States
- (Adem Yildirim):
| | - Dennis Shi
- Department of Chemical and Biological Engineering, University of Colorado Boulder. Boulder, Colorado 80303, United States
| | - Shambojit Roy
- Department of Chemical and Biological Engineering, University of Colorado Boulder. Boulder, Colorado 80303, United States
| | - Nicholas T. Blum
- Department of Chemical and Biological Engineering, University of Colorado Boulder. Boulder, Colorado 80303, United States
| | - Rajarshi Chattaraj
- Department of Mechanical Engineering, University of Colorado Boulder. Boulder, Colorado 80309, United States
| | - Jennifer N. Cha
- Department of Chemical and Biological Engineering, University of Colorado Boulder. Boulder, Colorado 80303, United States
| | - Andrew P. Goodwin
- Department of Chemical and Biological Engineering, University of Colorado Boulder. Boulder, Colorado 80303, United States
- Corresponding Author (Andrew P. Goodwin):
| |
Collapse
|
17
|
Han M, Wang N, Guo S, Chang N, Lu S, Wan M. Nakagami-m parametric imaging for characterization of thermal coagulation and cavitation erosion induced by HIFU. ULTRASONICS SONOCHEMISTRY 2018; 45:78-85. [PMID: 29705328 DOI: 10.1016/j.ultsonch.2018.03.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Revised: 03/13/2018] [Accepted: 03/15/2018] [Indexed: 06/08/2023]
Abstract
Nowadays, both thermal and mechanical ablation techniques of HIFU associated with cavitation have been developed for noninvasive treatment. A specific challenge for the successful clinical implementation of HIFU is to achieve real-time imaging for the evaluation and determination of therapy outcomes such as necrosis or homogenization. Ultrasound Nakagami-m parametric imaging highlights the degrading shadowing effects of bubbles and can be used for tissue characterization. The aim of this study is to investigate the performance of Nakagami-m parametric imaging for evaluating and differentiating thermal coagulation and cavitation erosion induced by HIFU. Lesions were induced in basic bovine serum albumin (BSA) phantoms and ex vivo porcine livers using a 1.6 MHz single-element transducer. Thermal and mechanical lesions induced by two types of HIFU sequences respectively were evaluated using Nakagami-m parametric imaging and ultrasound B-mode imaging. The lesion sizes estimated using Nakagami-m parametric imaging technique were all closer to the actual sizes than those of B-mode imaging. The p-value obtained from the t-test between the mean m values of thermal coagulation and cavitation erosion was smaller than 0.05, demonstrating that the m values of thermal lesions were significantly different from that of mechanical lesions, which was confirmed by ex vivo experiments and histologic examination showed that different changes result from HIFU exposure, one of tissue dehydration resulting from the thermal effect, and the other of tissue homogenate resulting from mechanical effect. This study demonstrated that Nakagami-m parametric imaging is a potential real-time imaging technique for evaluating and differentiating thermal coagulation and cavitation erosion.
Collapse
Affiliation(s)
- Meng Han
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Na Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Shifang Guo
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Nan Chang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Shukuan Lu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China.
| |
Collapse
|
18
|
Bigelow TA, Thomas CL, Wu H, Itani KMF. Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh Samples Under Varying Pulse Durations. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64. [PMID: 28650808 PMCID: PMC5819746 DOI: 10.1109/tuffc.2017.2718841] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Prior studies demonstrated that histotripsy generated by high-intensity tone bursts to excite a bubble cloud adjacent to a medical implant can destroy the bacteria biofilm responsible for the infection. The goal of this paper was to treat Staphylococcus aureus (S. aureus) biofilms on surgical mesh samples while varying the number of cycles in the tone burst to minimize collateral tissue damage while maximizing therapy effectiveness. S. aureus biofilms were grown on 1-cm square surgical mesh samples. The biofilms were then treated in vitro using a spherically focused transducer (1.1 MHz, 12.9-cm focal length, 12.7-cm diameter) using either a sham exposure or histotripsy pulses with tone burst durations of 3, 5, or 10 cycles (pulse repetition frequency of 333 Hz, peak compressional pressure of 150 MPa, peak rarefactional pressure of 17 MPa). After treatment, the number of colony forming units (CFUs) on the mesh and the surrounding gel was independently determined. The number of CFUs remaining on the mesh for the sham exposure (4.8 ± 0.9-log10) (sample mean ± sample standard deviation-log10 from 15 observations) was statistically significantly different from the 3-cycle (1.9 ± 1.5-log10), 5-cycle (2.2 ± 1.1-log10), and 10-cycle exposures (1 ± 1.5-log10) with an average reduction in the number of CFUs of 3.1-log10. The numbers of CFUs released into the gel for both the sham and exposure groups were the same within a bound of 0.86-log10, but this interval was too large to deduce the fate of the bacteria in the biofilm following the treatment.
Collapse
|
19
|
Seo J, Kim YS. Ultrasound imaging and beyond: recent advances in medical ultrasound. Biomed Eng Lett 2017; 7:57-58. [PMID: 30603151 PMCID: PMC6208470 DOI: 10.1007/s13534-017-0030-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2017] [Revised: 04/09/2017] [Accepted: 04/10/2017] [Indexed: 11/30/2022] Open
Affiliation(s)
- Jongbum Seo
- Department of Biomedical Engineering, Yonsei University, 304 Medical Industry Techno Tower, Wonju, Gangwon 220-710 Republic of Korea
| | - Young-sun Kim
- Uterine Fibroid Integrated Management Center, MINT Intervention Hospital, Seoul, 26493 Republic of Korea
| |
Collapse
|
20
|
Kubota R, Yamashita Y, Kenmotsu T, Yoshikawa Y, Yoshida K, Watanabe Y, Imanaka T, Yoshikawa K. Double-Strand Breaks in Genome-Sized DNA Caused by Ultrasound. Chemphyschem 2017; 18:959-964. [PMID: 28170150 PMCID: PMC5413823 DOI: 10.1002/cphc.201601325] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Indexed: 11/10/2022]
Abstract
DNA double-strand breaks (DSBs) caused by ultrasound were evaluated in a quantitative manner by single-molecule fluorescence microscopy. We compared the effect of time-interval (or pulse) sonication to that of continuous wave (CW) sonication at a fixed frequency of 30 kHz. Pulses caused fewer DSBs than CW sonication under the same total input ultrasound energy when the pulse repetition period was above the order of a second. In contrast, pulses caused more DSBs than CW sonication for pulse widths shorter than a second. These effect of ultrasound on DNA were interpreted in terms of the time-dependent decay in the probability of breakage during the duration of a pulse. We propose a simple phenomenological model by considering a characteristic decay in the probability of DSBs during single-pulse sonication, which reproduces the essence of the experimental trend. In addition, a data analysis revealed a characteristic scaling behavior between the number of pulses and the number of DSBs.
Collapse
Affiliation(s)
- Rinko Kubota
- Faculty of Life and Medical Sciences, Doshisha University, Tatara-Miyakodani, Kyotanabe, Kyoto, 610-0321, Japan
| | - Yusuke Yamashita
- Faculty of Life and Medical Sciences, Doshisha University, Tatara-Miyakodani, Kyotanabe, Kyoto, 610-0321, Japan
| | - Takahiro Kenmotsu
- Faculty of Life and Medical Sciences, Doshisha University, Tatara-Miyakodani, Kyotanabe, Kyoto, 610-0321, Japan
| | - Yuko Yoshikawa
- Faculty of Life and Medical Sciences, Doshisha University, Tatara-Miyakodani, Kyotanabe, Kyoto, 610-0321, Japan
| | - Kenji Yoshida
- Center for Frontier Medical Engineering, Chiba University, Chiba, 263-0022, Japan
| | - Yoshiaki Watanabe
- Faculty of Life and Medical Sciences, Doshisha University, Tatara-Miyakodani, Kyotanabe, Kyoto, 610-0321, Japan
| | - Tadayuki Imanaka
- Research Organization of Science and Technology, Ritsumeikan University, Kusatsu, 525-8577, Japan
| | - Kenichi Yoshikawa
- Faculty of Life and Medical Sciences, Doshisha University, Tatara-Miyakodani, Kyotanabe, Kyoto, 610-0321, Japan
| |
Collapse
|
21
|
Lafond M, Prieur F, Chavrier F, Mestas JL, Lafon C. Numerical study of a confocal ultrasonic setup for cavitation creation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 141:1953. [PMID: 28372123 DOI: 10.1121/1.4978061] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Acoustic cavitation has found a wide range of applications in the last few decades. For potential applications involving cavitation, the acoustic characteristics of a confocal ultrasonic setup are studied: two high-intensity focused ultrasound transducers are mounted so that their focal points overlap. A mathematical simulator is developed that takes into account nonlinear propagation, absorption, and diffraction. Each one of these physical effects is solved in the frequency domain for successive planes. Comparing the confocal setup with equivalent single transducer setups, it is shown that, with the confocal configuration, nonlinear distortion of the waveform is reduced, resulting in a greater peak rarefactional pressure and a lower peak positive pressure. Furthermore, additional features are investigated for confocal configurations such as a greater spatial stability for the focal point, which can be maintained while increasing the pressure level, and a focal region consisting of interference acting as an acoustic trap.
Collapse
Affiliation(s)
- Maxime Lafond
- Institut National de la Santé et de la Recherche Médicale, U1032, Laboratory of Therapeutic Applications of Ultrasound, 151 Cours Albert Thomas, Lyon, F-69003, France
| | - Fabrice Prieur
- Institut National de la Santé et de la Recherche Médicale, U1032, Laboratory of Therapeutic Applications of Ultrasound, 151 Cours Albert Thomas, Lyon, F-69003, France
| | - Françoise Chavrier
- Institut National de la Santé et de la Recherche Médicale, U1032, Laboratory of Therapeutic Applications of Ultrasound, 151 Cours Albert Thomas, Lyon, F-69003, France
| | - Jean-Louis Mestas
- Institut National de la Santé et de la Recherche Médicale, U1032, Laboratory of Therapeutic Applications of Ultrasound, 151 Cours Albert Thomas, Lyon, F-69003, France
| | - Cyril Lafon
- Institut National de la Santé et de la Recherche Médicale, U1032, Laboratory of Therapeutic Applications of Ultrasound, 151 Cours Albert Thomas, Lyon, F-69003, France
| |
Collapse
|
22
|
Yin H, Chang N, Xu S, Wan M. Sonoluminescence characterization of inertial cavitation inside a BSA phantom treated by pulsed HIFU. ULTRASONICS SONOCHEMISTRY 2016; 32:158-164. [PMID: 27150756 DOI: 10.1016/j.ultsonch.2016.02.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 02/28/2016] [Accepted: 02/29/2016] [Indexed: 06/05/2023]
Abstract
The aim of this study was to investigate the inertial cavitation inside a phantom treated by pulsed HIFU (pHIFU). Basic bovine serum albumin (BSA) phantoms without any inherent ultrasound contrast agents (UCAs) or phase-shift nano-emulsions (PSNEs) were used. During the treatment, sonoluminescence (SL) recordings were performed to characterize the spatial distribution of inertial cavitation adjacent to the focal region. High-speed photographs and thermal coagulations, comparing with the SL results, were also recorded and presented. A series of pulse parameters (pulse duration (PD) was between 1 and 23 cycles and pulse repetition frequency (PRF) was between 0.5kHz and 100kHz) were performed to make a systematic investigation under certain acoustic power (APW). Continuous HIFU (cHIFU) investigation was also performed to serve as control group. It was found that, when APW was 19.5W, pHIFU with short PD was much easier to form SL adjacent to the focal region inside the phantom, while it was difficult for cHIFU to generate cavitation bubbles. With appropriate PD and PRF, the residual bubbles of the previous pulses could be stimulated by the incident pulses to oscillate in a higher level and even violently collapse, resulting to enhanced physical thermogenesis. The experimental results showed that the most violent inertial cavitation occurs when PD was set to 6 cycles (5μs) and PRF to 10kHz, while the highest level of thermal coagulation was observed when PD was set to 10 cycles. The cavitational and thermal characteristics were in good correspondence, exhibiting significant potentiality regarding to inject-free cavitation bubble enhanced thermal ablation under lower APW, compared to the conventional thermotherapy.
Collapse
Affiliation(s)
- Hui Yin
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, PR China
| | - Nan Chang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, PR China
| | - Shanshan Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, PR China
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, PR China.
| |
Collapse
|
23
|
Shi A, Huang P, Guo S, Zhao L, Jia Y, Zong Y, Wan M. Precise spatial control of cavitation erosion in a vessel phantom by using an ultrasonic standing wave. ULTRASONICS SONOCHEMISTRY 2016; 31:163-172. [PMID: 26964937 DOI: 10.1016/j.ultsonch.2015.12.016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2015] [Revised: 12/20/2015] [Accepted: 12/21/2015] [Indexed: 06/05/2023]
Abstract
In atherosclerotic inducement in animal models, the conventionally used balloon injury is invasive, produces excessive vessel injuries at unpredictable locations and is inconvenient in arterioles. Fortunately, cavitation erosion, which plays an important role in therapeutic ultrasound in blood vessels, has the potential to induce atherosclerosis noninvasively at predictable sites. In this study, precise spatial control of cavitation erosion for superficial lesions in a vessel phantom was realised by using an ultrasonic standing wave (USW) with the participation of cavitation nuclei and medium-intensity ultrasound pulses. The superficial vessel erosions were restricted between adjacent pressure nodes, which were 0.87 mm apart in the USW field of 1 MHz. The erosion positions could be shifted along the vessel by nodal modulation under a submillimetre-scale accuracy without moving the ultrasound transducers. Moreover, the cavitation erosion of the proximal or distal wall could be determined by the types of cavitation nuclei and their corresponding cavitation pulses, i.e., phase-change microbubbles with cavitation pulses of 5 MHz and SonoVue microbubbles with cavitation pulses of 1 MHz. Effects of acoustic parameters of the cavitation pulses on the cavitation erosions were investigated. The flow conditions in the experiments were considered and discussed. Compared to only using travelling waves, the proposed method in this paper improves the controllability of the cavitation erosion and reduces the erosion depth, providing a more suitable approach for vessel endothelial injury while avoiding haemorrhage.
Collapse
Affiliation(s)
- Aiwei Shi
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Peixuan Huang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Shifang Guo
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Lu Zhao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Yingjie Jia
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Yujin Zong
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China.
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China.
| |
Collapse
|
24
|
Suarez Castellanos IM, Balteanu B, Singh T, Zderic V. Therapeutic Modulation of Calcium Dynamics Using Ultrasound and Other Energy-Based Techniques. IEEE Rev Biomed Eng 2016; 9:177-191. [DOI: 10.1109/rbme.2016.2555760] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
25
|
Lafond M, Mestas JL, Prieur F, Chettab K, Geraci S, Clézardin P, Lafon C. Unseeded Inertial Cavitation for Enhancing the Delivery of Chemotherapies: A Safety Study. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:220-231. [PMID: 26478278 DOI: 10.1016/j.ultrasmedbio.2015.08.019] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2015] [Revised: 08/26/2015] [Accepted: 08/27/2015] [Indexed: 06/05/2023]
Abstract
Acoustic cavitation can improve local drug delivery in tumors. Without injected external nucleation agents, initiating inertial cavitation requires high negative pressures, which can lead to biological damage. In the present study, unseeded inertial cavitation was obtained in vivo using confocal beams, and the effect of these exposure conditions was assessed on drug structure and activity, shallow tissues and growth of breast tumors. No change was observed in the structure and cytotoxicity of doxorubicin. Experiments were conducted on healthy rats, exposing the thigh and abdomen. Histologic analyses at 72 h and 2 weeks post-treatment demonstrated a modest impact on tissues. Syngeneic 4 T1 breast tumors in mice were sonicated. Immunohistochemical analyses showed that ultrasound did not impact vascular density, proliferation and apoptosis of cancer cells. In addition, ultrasound did not negatively modify cancer cell spreading to the lungs and bone marrow. This provides evidence that these particular parameters can be used safely in vivo.
Collapse
Affiliation(s)
- Maxime Lafond
- Inserm, U1032, LabTAU, Lyon, F-69003, France; Université de Lyon, Lyon, F-69003, France.
| | - Jean-Louis Mestas
- Inserm, U1032, LabTAU, Lyon, F-69003, France; Université de Lyon, Lyon, F-69003, France; Caviskills SAS, Vaulx-En-Velin, F-69120, France
| | - Fabrice Prieur
- Inserm, U1032, LabTAU, Lyon, F-69003, France; Université de Lyon, Lyon, F-69003, France
| | - Kamel Chettab
- Inserm, U1052, Centre de Recherche de Cancérologie de Lyon, Lyon, F-69003, France
| | - Sandra Geraci
- Inserm, U1033, Lyon, F-69003, France; UFR de Médecine Lyon-Est, Lyon, F-69372, France
| | - Philippe Clézardin
- Inserm, U1033, Lyon, F-69003, France; UFR de Médecine Lyon-Est, Lyon, F-69372, France
| | - Cyril Lafon
- Inserm, U1032, LabTAU, Lyon, F-69003, France; Université de Lyon, Lyon, F-69003, France; Caviskills SAS, Vaulx-En-Velin, F-69120, France
| |
Collapse
|
26
|
Zhang X, Jin L, Vlaisavljevich E, Owens GE, Gurm HS, Cain CA, Xu Z. Noninvasive thrombolysis using microtripsy: a parameter study. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:2092-105. [PMID: 26670850 PMCID: PMC4824290 DOI: 10.1109/tuffc.2015.007268] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Histotripsy fractionates soft tissue by well-controlled acoustic cavitation using microsecond-long, high-intensity ultrasound pulses. The feasibility of using histotripsy as a noninvasive, drug-free, and image-guided thrombolysis method has been shown previously. A new histotripsy approach, termed microtripsy, has recently been investigated for the thrombolysis application to improve treatment accuracy and avoid potential vessel damage. In this study, we investigated the effects of pulse repetition frequency (PRF) on microtripsy thrombolysis. Microtripsy thrombolysis treatments using different PRFs (5, 50, and 100 Hz) and doses (20, 50, and 100 pulses) were performed on blood clots in an in vitro vessel flow model. To quantitatively evaluate the microtripsy thrombolysis effect, the location of focal cavitation, the incident rate of pre-focal cavitation on the vessel wall, the size and location of the resulting flow channel, and the generated clot debris particles were measured. The results demonstrated that focal cavitation was always well confined in the vessel lumen without contacting the vessel wall for all PRFs. Pre-focal cavitation on the front vessel wall was never observed at 5Hz PRF, but occasionally observed at PRFs of 50 Hz (1.2%) and 100 Hz (5.4%). However, the observed pre-focal cavitation was weak and did not significantly affect the focal cavitation. Results further demonstrated that, although the extent of clot fractionation per pulse was the highest at 5 Hz PRF at the beginning of treatment (<20 pulses), 100 Hz PRF generated the largest flow channels with a much shorter treatment time. Finally, results showed fewer large debris particles were generated at a higher PRF. Overall, the results of this study suggest that a higher PRF (50 or 100 Hz) may be a better choice for microtripsy thrombolysis to use clinically due to the larger resulting flow channel, shorter treatment time, and smaller debris particles.
Collapse
Affiliation(s)
- Xi Zhang
- Department of Biomedical Engineering, University of Michigan, Ann
Arbor, MI, USA
| | - Lifang Jin
- Department of Biomedical Engineering, University of Michigan, Ann
Arbor, MI, USA
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering, University of Michigan, Ann
Arbor, MI, USA
| | - Gabe E. Owens
- Department of Biomedical Engineering, University of Michigan, Ann
Arbor, MI, USA
- Department of Pediatrics and Communicable Diseases, University of
Michigan, Ann Arbor, MI, USA
| | - Hitinder S. Gurm
- Department of Internal Medicine, University of Michigan, Ann Arbor,
MI, USA
| | - Charles A. Cain
- Department of Biomedical Engineering, University of Michigan, Ann
Arbor, MI, USA
| | - Zhen Xu
- Department of Biomedical Engineering, University of Michigan, Ann
Arbor, MI, USA
- Department of Pediatrics and Communicable Diseases, University of
Michigan, Ann Arbor, MI, USA
| |
Collapse
|
27
|
Wang YU, Chen YN, Zhang W, Yang YU, Bai WK, Shen E, Hu B. Upregulation of ULK1 expression in PC-3 cells following tumor protein P53 transfection by sonoporation. Oncol Lett 2015; 11:699-704. [PMID: 26870270 DOI: 10.3892/ol.2015.3946] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2014] [Accepted: 08/07/2015] [Indexed: 11/06/2022] Open
Abstract
The aim of the present study was to investigate whether ultrasound combined with microbubbles was able to enhance liposome-mediated transfection of genes into human prostate cancer cells, and to examine the association between autophagy and tumor protein P53 (P53). An MTT assay was used to evaluate cell viability, while flow cytometry and fluorescence microscopy were used to measure gene transfection efficiency. Autophagy was observed using transmission electron microscopy. Reverse transcription-polymerase chain reaction (RT-PCR) and western blot analysis were used to assess the expression of autophagy-associated genes. The results of the present study revealed that cell viability was significantly reduced following successfully enhanced transfection of P53 by ultrasound combined with microbubbles. In addition, serine/threonine-protein kinase ULK1 levels were simultaneously upregulated. Castration-resistant prostate cancer is difficult to treat and is investigated in the present study. P53 has a significant role in a number of key biological functions, including DNA repair, apoptosis, cell cycle, autophagy, senescence and angiogenesis. Prior to the present study, to the best of our knowledge, increased transfection efficiency and reduced side effects have been difficult to achieve. Ultrasound is considered to be a 'gentle' technique that may be able to achieve increased transfection efficiency and reduced side effects. The results of the present study highlight a potential novel therapeutic strategy for the treatment of prostate cancer.
Collapse
Affiliation(s)
- Y U Wang
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, P.R. China
| | - Yi-Ni Chen
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, P.R. China
| | - Wei Zhang
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, P.R. China
| | - Y U Yang
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, P.R. China
| | - Wen-Kun Bai
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, P.R. China
| | - E Shen
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, P.R. China
| | - Bing Hu
- Department of Ultrasound in Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, P.R. China
| |
Collapse
|
28
|
Vlaisavljevich E, Aydin O, Yuksel Durmaz Y, Lin KW, Fowlkes B, ElSayed M, Xu Z. Effects of Ultrasound Frequency on Nanodroplet-Mediated Histotripsy. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2135-47. [PMID: 25959056 DOI: 10.1016/j.ultrasmedbio.2015.04.007] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Revised: 04/02/2015] [Accepted: 04/07/2015] [Indexed: 05/13/2023]
Abstract
Nanodroplet-mediated histotripsy (NMH) is a targeted ultrasound ablation technique combining histotripsy with nanodroplets that can be selectively delivered to tumor cells for targeted tumor ablation. In a previous study, it was reported that by use of extremely short, high-pressure pulses, histotripsy cavitation bubbles were generated in regions containing nanodroplets at significantly lower pressure (∼10.8 MPa) than without nanodroplets (∼28 MPa) at 500 kHz. Furthermore, it was hypothesized that lower frequency would improve the effectiveness of NMH by increasing the size of the focal region, increasing bubble expansion, and decreasing the cavitation threshold. In this study, we investigated the effects of ultrasound frequency (345 kHz, 500 kHz, 1.5 MHz, and 3 MHz) on NMH. First, the NMH cavitation threshold was measured in tissue phantoms with and without nanodroplets, with results indicating that the NMH threshold was significantly below the histotripsy intrinsic threshold at all frequencies. Results also indicated that the NMH threshold decreased at lower frequency, ranging from 7.4 MPa at 345 kHz to 13.2 MPa at 3 MHz. In the second part of this study, the effects of frequency on NMH bubble expansion were investigated, with results indicating larger expansion at lower frequency, even at a lower pressure. In the final part of this study, the ability of perfluoropentane-encapsulated nanodroplets to act as sustainable cavitation nuclei over multiple pulses was investigated, with results indicating that the nanodroplets are destroyed by the cavitation process and only function as cavitation nuclei for the first few pulses, with this effect being most pronounced at higher frequencies. Overall, the results of this study support our hypothesis that using a lower frequency will improve the effectiveness of NMH by increasing the size of the focal region, increasing bubble expansion and decreasing the cavitation threshold.
Collapse
Affiliation(s)
- Eli Vlaisavljevich
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Omer Aydin
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Yasemin Yuksel Durmaz
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Department of Biomedical Engineering, Istanbul Medipol University, Istanbul, Turkey
| | - Kuang-Wei Lin
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Brian Fowlkes
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA
| | - Mohamed ElSayed
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Macromolecular Science and Engineering Program, University of Michigan, Ann Arbor, Michigan, USA
| | - Zhen Xu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Division of Pediatric Cardiology, Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan, USA.
| |
Collapse
|
29
|
Prieur F, Zorgani A, Catheline S, Souchon R, Mestas JL, Lafond M, Lafon C. Observation of a cavitation cloud in tissue using correlation between ultrafast ultrasound images. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:1256-64. [PMID: 26168172 DOI: 10.1109/tuffc.2014.006905] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The local application of ultrasound is known to improve drug intake by tumors. Cavitating bubbles are one of the contributing effects. A setup in which two ultrasound transducers are placed confocally is used to generate cavitation in ex vivo tissue. As the transducers emit a series of short excitation bursts, the evolution of the cavitation activity is monitored using an ultrafast ultrasound imaging system. The frame rate of the system is several thousands of images per second, which provides several tens of images between consecutive excitation bursts. Using the correlation between consecutive images for speckle tracking, a decorrelation of the imaging signal appears due to the creation, fast movement, and dissolution of the bubbles in the cavitation cloud. By analyzing this area of decorrelation, the cavitation cloud can be localized and the spatial extent of the cavitation activity characterized.
Collapse
|
30
|
Vlaisavljevich E, Lin KW, Maxwell A, Warnez MT, Mancia L, Singh R, Putnam AJ, Fowlkes B, Johnsen E, Cain C, Xu Z. Effects of ultrasound frequency and tissue stiffness on the histotripsy intrinsic threshold for cavitation. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1651-67. [PMID: 25766571 PMCID: PMC4426049 DOI: 10.1016/j.ultrasmedbio.2015.01.028] [Citation(s) in RCA: 119] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2014] [Revised: 01/26/2015] [Accepted: 01/26/2015] [Indexed: 05/04/2023]
Abstract
Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Previous work has indicated that a cavitation cloud can be formed by a single pulse with one high-amplitude negative cycle, when the negative pressure amplitude directly exceeds a pressure threshold intrinsic to the medium. We hypothesize that the intrinsic threshold in water-based tissues is determined by the properties of the water inside the tissue, and changes in tissue stiffness or ultrasound frequency will have a minimal impact on the histotripsy intrinsic threshold. To test this hypothesis, the histotripsy intrinsic threshold was investigated both experimentally and theoretically. The probability of cavitation was measured by subjecting tissue phantoms with adjustable mechanical properties and ex vivo tissues to a histotripsy pulse of 1-2 cycles produced by 345-kHz, 500-kHz, 1.5-MHz and 3-MHz histotripsy transducers. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured versus pressure amplitude. The results revealed that the intrinsic threshold (the negative pressure at which probability = 0.5) is independent of stiffness for Young's moduli (E) <1 MPa, with only a small increase (∼2-3 MPa) in the intrinsic threshold for tendon (E = 380 MPa). Additionally, results for all samples revealed only a small increase of ∼2-3 MPa when the frequency was increased from 345 kHz to 3 MHz. The intrinsic threshold was measured to be between 24.7 and 30.6 MPa for all samples and frequencies tested in this study. Overall, the results of this study indicate that the intrinsic threshold to initiate a histotripsy bubble cloud is not significantly affected by tissue stiffness or ultrasound frequency in the hundreds of kilohertz to megahertz range.
Collapse
Affiliation(s)
- Eli Vlaisavljevich
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
| | - Kuang-Wei Lin
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Adam Maxwell
- Department of Urology, University of Washington, Seattle, Washington, USA
| | - Matthew T Warnez
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Lauren Mancia
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Rahul Singh
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Andrew J Putnam
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Brian Fowlkes
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA
| | - Eric Johnsen
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Charles Cain
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Zhen Xu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA; Division of Pediatric Cardiology, Department of Pediatrics and Communicable Diseases, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
31
|
Hu H, Xu S, Yuan Y, Liu R, Wang S, Wan M. Spatial-temporal ultrasound imaging of residual cavitation bubbles around a fluid-tissue interface in histotripsy. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 137:2563-2572. [PMID: 25994689 DOI: 10.1121/1.4919286] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Cavitation is considered as the primary mechanism of soft tissue fragmentation (histotripsy) by pulsed high-intensity focused ultrasound. The residual cavitation bubbles have a dual influence on the histotripsy pulses: these serve as nuclei for easy generation of new cavitation, and act as strong scatterers causing energy "shadowing." To monitor the residual cavitation bubbles in histotripsy, an ultrafast active cavitation imaging method with relatively high signal-to-noise ratio and good spatial-temporal resolution was proposed in this paper, which combined plane wave transmission, minimum variance beamforming, and coherence factor weighting. The spatial-temporal evolutions of residual cavitation bubbles around a fluid-tissue interface in histotripsy under pulse duration (PD) of 10-40 μs and pulse repetition frequency (PRF) of 0.67-2 kHz were monitored by this method. The integrated bubble area curves inside the tissue interface were acquired from the bubble image sequence, and the formation process of histotripsy damage was estimated. It was observed that the histotripsy efficiency decreased with both longer PDs and higher PRFs. A direct relationship with a coefficient of 1.0365 between histotripsy lesion area and inner residual bubble area was found. These results can assist in monitoring and optimization of the histotripsy treatment further.
Collapse
Affiliation(s)
- Hong Hu
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Shanshan Xu
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Yuan Yuan
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Runna Liu
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Supin Wang
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| |
Collapse
|
32
|
Vlaisavljevich E, Lin KW, Warnez MT, Singh R, Mancia L, Putnam AJ, Johnsen E, Cain C, Xu Z. Effects of tissue stiffness, ultrasound frequency, and pressure on histotripsy-induced cavitation bubble behavior. Phys Med Biol 2015; 60:2271-92. [PMID: 25715732 DOI: 10.1088/0031-9155/60/6/2271] [Citation(s) in RCA: 86] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Histotripsy is an ultrasound ablation method that controls cavitation to fractionate soft tissue. In order to effectively fractionate tissue, histotripsy requires cavitation bubbles to rapidly expand from nanometer-sized initial nuclei into bubbles often larger than 50 µm. Using a negative pressure high enough to initiate a bubble cloud and expand bubbles to a sufficient size, histotripsy has been shown capable of completely fractionating soft tissue into acelluar debris resulting in effective tissue removal. Previous work has shown that the histotripsy process is affected by tissue mechanical properties with stiffer tissues showing increased resistance to histotripsy fractionation, which we hypothesize to be caused by impeded bubble expansion in stiffer tissues. In this study, the hypothesis that increases in tissue stiffness cause a reduction in bubble expansion was investigated both theoretically and experimentally. High speed optical imaging was used to capture a series of time delayed images of bubbles produced inside mechanically tunable agarose tissue phantoms using histotripsy pulses produced by 345 kHz, 500 kHz, 1.5 MHz, and 3 MHz histotripsy transducers. The results demonstrated a significant decrease in maximum bubble radius (Rmax) and collapse time (tc) with both increasing Young's modulus and increasing frequency. Furthermore, results showed that Rmax was not increased by raising the pressure above the intrinsic threshold. Finally, this work demonstrated the potential of using a dual-frequency strategy to modulate the expansion of histotripsy bubbles. Overall, the results of this study improve our understanding of how tissue stiffness and ultrasound parameters affect histotripsy-induced bubble behavior and provide a rational basis to tailor acoustic parameters for treatment of the specific tissues of interest.
Collapse
Affiliation(s)
- Eli Vlaisavljevich
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Darnell SE, Hall TL, Tomlins SA, Cheng X, Ives KA, Roberts WW. Histotripsy of the Prostate in a Canine Model: Characterization of Post-Therapy Inflammation and Fibrosis. J Endourol 2015; 29:810-5. [PMID: 25566880 DOI: 10.1089/end.2014.0585] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
INTRODUCTION Histotripsy is a nonthermal, noninvasive, pulsed ultrasound technology that homogenizes tissue within the targeted volume. From previous experiments, it appeared that the resultant fibrotic response from histotripsy was limited compared with the typical tissue response seen after thermoablation. The objective of this study was to characterize the inflammatory response and quantify patterns of collagen deposition 6 weeks after in vivo canine prostate histotripsy. METHODS Histotripsy was applied to the left half of eight canine prostates to produce an intraparenchymal zone of tissue homogenization. Six weeks after treatment, prostates were harvested, sectioned, and stained with hematoxylin and eosin for histologic evaluation, CD3, CD20, and Mac387 immunohistochemistry to characterize the inflammatory components, and picrosirius red staining to identify collagen. RESULTS Seven of eight treated prostates exhibited only minimal residual inflammation. Visual microscopic analysis of picrosirius red slides revealed a band of dense collagen (0.5 mm wide) immediately adjacent to the cavity produced by histotripsy. This was surrounded by a second band (1 mm wide) of less dense collagen interspersed among glandular architecture. A lobar distribution of epithelial atrophy and basal cell hyperplasia reminiscent of periurethral glands and ducts was apparent surrounding the margin of the treatment cavities. Tissue loss (-31%) was apparent on the treated side of all prostates while four demonstrated a net decrease in collagen content. CONCLUSIONS In vivo histotripsy of canine prostate produced a decrease in prostate volume coupled with a limited inflammatory and fibrotic response. A narrow (1.5 mm) band of fibrosis around the empty, reepithelialized treatment cavity was observed 6 weeks after treatment. In four cases, an overall reduction in collagen content was measured. Further studies are planned to correlate these histologic findings with alteration in mechanical tissue properties and to explore histotripsy strategies for treatment of benign prostatic hyperplasia that optimize tissue volume removal with minimization of fibrosis.
Collapse
Affiliation(s)
- Sarah E Darnell
- 1 Department of Biomedical Engineering, University of Michigan , Ann Arbor, Michigan
| | - Timothy L Hall
- 1 Department of Biomedical Engineering, University of Michigan , Ann Arbor, Michigan
| | - Scott A Tomlins
- 2 Department of Pathology, University of Michigan , Ann Arbor, Michigan
| | - Xu Cheng
- 3 Department of Urology, University of Michigan , Ann Arbor, Michigan
| | - Kimberly A Ives
- 1 Department of Biomedical Engineering, University of Michigan , Ann Arbor, Michigan
| | - William W Roberts
- 3 Department of Urology, University of Michigan , Ann Arbor, Michigan
| |
Collapse
|
34
|
Xu J, Bigelow TA, Davis G, Avendano A, Shrotriya P, Bergler K, Hu Z. Dependence of ablative ability of high-intensity focused ultrasound cavitation-based histotripsy on mechanical properties of agar. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 136:3018. [PMID: 25480051 DOI: 10.1121/1.4898426] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Cavitation-based histotripsy uses high-intensity focused ultrasound at low duty factor to create bubble clouds inside tissue to liquefy a region, and provides better fidelity to planned lesion coordinates and the ability to perform real-time monitoring. The goal of this study was to identify the most important mechanical properties for predicting lesion dimensions, among these three: Young's modulus, bending strength, and fracture toughness. Lesions were generated inside tissue-mimicking agar, and correlations were examined between the mechanical properties and the lesion dimensions, quantified by lesion volume and by the width and length of the equivalent bubble cluster. Histotripsy was applied to agar samples with varied properties. A cuboid of 4.5 mm width (lateral to focal plane) and 6 mm depth (along beam axis) was scanned in a raster pattern with respective step sizes of 0.75 and 3 mm. The exposure at each treatment location was either 15, 30, or 60 s. Results showed that only Young's modulus influenced histotripsy's ablative ability and was significantly correlated with lesion volume and bubble cluster dimensions. The other two properties had negligible effects on lesion formation. Also, exposure time differentially affected the width and depth of the bubble cluster volume.
Collapse
Affiliation(s)
- Jin Xu
- Department of Mechanical Engineering, Iowa State University, Black Engineering Hall, Ames, Iowa 50011
| | - Timothy A Bigelow
- Department of Electrical and Computer Engineering, Iowa State University, Coover Hall, Ames, Iowa 50011
| | - Gabriel Davis
- Department of Mechanical Engineering, Iowa State University, Black Engineering Hall, Ames, Iowa 50011
| | - Alex Avendano
- Department of Mechanical Engineering, Iowa State University, Black Engineering Hall, Ames, Iowa 50011
| | - Pranav Shrotriya
- Department of Mechanical Engineering, Iowa State University, Black Engineering Hall, Ames, Iowa 50011
| | - Kevin Bergler
- Department of Mechanical Engineering, Iowa State University, Black Engineering Hall, Ames, Iowa 50011
| | - Zhong Hu
- Department of Electrical and Computer Engineering, Iowa State University, Coover Hall, Ames, Iowa 50011
| |
Collapse
|
35
|
Liberman A, Wu Z, Barback CV, Viveros RD, Wang J, Ellies LG, Mattrey RF, Trogler WC, Kummel AC, Blair SL. Hollow iron-silica nanoshells for enhanced high intensity focused ultrasound. J Surg Res 2014; 190:391-8. [PMID: 24972734 PMCID: PMC4141695 DOI: 10.1016/j.jss.2014.05.009] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2014] [Revised: 03/27/2014] [Accepted: 05/02/2014] [Indexed: 12/30/2022]
Abstract
BACKGROUND High intensity-focused ultrasound (HIFU) is an alterative ablative technique currently being investigated for local treatment of breast cancer and fibroadenomas. Current HIFU therapies require concurrent magnetic resonance imaging monitoring. Biodegradable 500 nm perfluoropentane-filled iron-silica nanoshells have been synthesized as a sensitizing agent for HIFU therapies, which aid both mechanical and thermal ablation of tissues. In low duty cycle high-intensity applications, rapid tissue damage occurs from mechanical rather than thermal effects, which can be monitored closely by ultrasound obviating the need for concurrent magnetic resonance imaging. MATERIALS AND METHODS Iron-silica nanoshells were synthesized by a sol-gel method on polystyrene templates and calcined to yield hollow nanoshells. The nanoshells were filled with perfluoropentane and injected directly into excised human breast tumor, and intravenously (IV) into healthy rabbits and Py8119 tumor-bearing athymic nude mice. HIFU was applied at 1.1 MHz and 3.5 MPa at a 2% duty cycle to achieve mechanical ablation. RESULTS Ex vivo in excised rabbit livers, the time to visually observable damage with HIFU was 20 s without nanoshells and only 2 s with nanoshells administered IV before sacrifice. Nanoshells administered IV into nude mice with xenograft tumors were activated in vivo by HIFU 24 h after administration. In this xenograft model, applied HIFU resulted in a 13.6 ± 6.1 mm(3) bubble cloud with the IV injected particles and no bubble cloud without particles. CONCLUSIONS Iron-silica nanoshells can reduce the power and time to perform HIFU ablative therapy and can be monitored by ultrasound during low duty cycle operation.
Collapse
Affiliation(s)
- Alexander Liberman
- Materials Science and Engineering Program, University of California, San Diego
| | - Zhe Wu
- Department of Radiology, University of California, San Diego
| | | | - Robert D Viveros
- Department of Nanoengineering, University of California, San Diego
| | - James Wang
- Department of Nanoengineering, University of California, San Diego
| | - Lesley G Ellies
- Department of Pathology, University of California, San Diego
| | - Robert F Mattrey
- Department of Radiology, University of California, San Diego; Moores Cancer Center, University of California, San Diego
| | - William C Trogler
- Department of Chemistry and Biochemistry, University of California, San Diego
| | - Andrew C Kummel
- Department of Chemistry and Biochemistry, University of California, San Diego
| | - Sarah L Blair
- Moores Cancer Center, University of California, San Diego; Department of Surgery, University of California, San Diego.
| |
Collapse
|
36
|
Riesberg G, Bigelow TA, Stessman DJ, Spalding MH, Yao L, Wang T, Xu J. Flow rate and duty cycle effects in lysis of Chlamydomonas reinhardtii using high-energy pulsed focused ultrasound. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 135:3632-3638. [PMID: 24916410 DOI: 10.1121/1.4874627] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
To consider microalgae lipid biofuel as a viable energy source, it is a necessity to maximize algal cell lysis, lipid harvest, and thus biofuel production versus the energy used to lyse the cells. Previous techniques have been to use energy consumptive ultrasound waves in the 10-40 kHz range in a stationary exposure environment. This study evaluated the potential of using 1.1 MHz ultrasound pulses in a new flow through type chamber on Chlamydomonas reinhardtii as a model organism for cell breakage. The ultrasound was generated using a spherically focused transducer with a focal length of 6.34 cm and an active diameter of 6.36 cm driven by 20 cycle sine-wave tone bursts at varied pulse repetition frequencies. First, variations in flow rate were examined at a constant duty cycle of 3.6%. After assessing flow rates, the duty cycle was varied to further explore the dependence on the tone burst parameters. Cell lysis was assessed by quantifying protein and chlorophyll release into the supernatant as well as by lipid extractability. Appropriate flow rates with higher duty cycles led to statistically significant increases in cell lysis relative to controls and other exposure conditions.
Collapse
Affiliation(s)
- Grant Riesberg
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011
| | - Timothy A Bigelow
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011
| | - Dan J Stessman
- Department of Genetics, Development, and Cell Biology, Iowa State University, Ames, Iowa 50011
| | - Martin H Spalding
- Department of Genetics, Development, and Cell Biology, Iowa State University, Ames, Iowa 50011
| | - Linxing Yao
- Department of Food Science and Human Nutrition, Iowa State University, Ames, Iowa 50011
| | - Tong Wang
- Department of Food Science and Human Nutrition, Iowa State University, Ames, Iowa 50011
| | - Jin Xu
- John Brown University, Siloam Springs, Arkansas 72761
| |
Collapse
|
37
|
Bigelow TA, Xu J, Stessman DJ, Yao L, Spalding MH, Wang T. Lysis of Chlamydomonas reinhardtii by high-intensity focused ultrasound as a function of exposure time. ULTRASONICS SONOCHEMISTRY 2014; 21:1258-1264. [PMID: 24355286 DOI: 10.1016/j.ultsonch.2013.11.014] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2013] [Accepted: 11/25/2013] [Indexed: 06/03/2023]
Abstract
Efficient lysis of microalgae for lipid extraction is an important concern when processing biofuels. Historically, ultrasound frequencies in the range of 10-40 kHz have been utilized for this task. However, greater efficiencies might be achievable if higher frequencies could be used. In our study, we evaluated the potential of using 1.1 MHz ultrasound to lyse microalgae for biofuel production while using Chlamydomonas reinhardtii as a model organism. The ultrasound was generated using a spherically focused transducer with a focal length of 6.34 cm and an active diameter of 6.36 cm driven by 20 cycle sine-wave tone bursts at a pulse repetition frequency of 2 kHz (3.6% duty cycle). The time-average acoustic power output was 26.2 W while the spatial-peak-pulse-average intensity (ISPPA) for each tone burst was 41 kW/cm(2). The peak compressional and rarefactional pressures at the focus were 102 and 17 MPa, respectively. The exposure time was varied for the different cases in the experiments from 5s to 9 min and cell lysis was assessed by quantifying the percentage of protein and chlorophyll release into the supernate as well as the lipid extractability. Free radical generation and lipid oxidation for the different ultrasound exposures were also determined. We found that there was a statistically significant increase in lipid extractability for all of the exposures compared to the control. The longer exposures also completely fragmented the cells releasing almost all of the protein and chlorophyll into the supernate. The cavitation activity did not significantly increase lipid oxidation while there was a minor trend of increased free radical production with increased ultrasound exposure.
Collapse
Affiliation(s)
- Timothy A Bigelow
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; Department of Electrical and Computer Engineering, Iowa State University, Ames, IA 50011, USA.
| | - Jin Xu
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; Department of Engineering, John Brown University, Siloam Springs, AR 72761, USA
| | - Dan J Stessman
- Department of Genetics, Development, and Cell Biology, Iowa State University, Ames, IA 50011, USA
| | - Linxing Yao
- Department of Food Science and Human Nutrition, Iowa State University, Ames, IA 50011, USA
| | - Martin H Spalding
- Department of Genetics, Development, and Cell Biology, Iowa State University, Ames, IA 50011, USA
| | - Tong Wang
- Department of Food Science and Human Nutrition, Iowa State University, Ames, IA 50011, USA
| |
Collapse
|
38
|
Lin KW, Kim Y, Maxwell AD, Wang TY, Hall TL, Xu Z, Fowlkes JB, Cain CA. Histotripsy beyond the intrinsic cavitation threshold using very short ultrasound pulses: microtripsy. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:251-65. [PMID: 24474132 PMCID: PMC3966303 DOI: 10.1109/tuffc.2014.6722611] [Citation(s) in RCA: 114] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Histotripsy produces tissue fractionation through dense energetic bubble clouds generated by short, high-pressure, ultrasound pulses. Conventional histotripsy treatments have used longer pulses from 3 to 10 cycles, wherein the lesion-producing bubble cloud generation depends on the pressure-release scattering of very high peak positive shock fronts from previously initiated, sparsely distributed bubbles (the shock-scattering mechanism). In our recent work, the peak negative pressure (P-) for generation of dense bubble clouds directly by a single negative half cycle, the intrinsic threshold, was measured. In this paper, the dense bubble clouds and resulting lesions (in red blood cell phantoms and canine tissues) generated by these supra-intrinsic threshold pulses were studied. A 32-element, PZT-8, 500-kHz therapy transducer was used to generate very short (<2 cycles) histotripsy pulses at a pulse repetition frequency (PRF) of 1 Hz and P- from 24.5 to 80.7 MPa. The results showed that the spatial extent of the histotripsy-induced lesions increased as the applied P- increased, and the sizes of these lesions corresponded well to the estimates of the focal regions above the intrinsic cavitation threshold, at least in the lower pressure regime (P- = 26 to 35 MPa). The average sizes for the smallest reproducible lesions were approximately 0.9 × 1.7 mm (lateral × axial), significantly smaller than the -6-dB beamwidth of the transducer (1.8 × 4.0 mm). These results suggest that, using the intrinsic threshold mechanism, well-confined and microscopic lesions can be precisely generated and their spatial extent can be estimated based on the fraction of the focal region exceeding the intrinsic cavitation threshold. Because the supra-threshold portion of the negative half cycle can be precisely controlled, lesions considerably less than a wavelength are easily produced, hence the term microtripsy.
Collapse
|
39
|
Tomizawa M, Shinozaki F, Motoyoshi Y, Sugiyama T, Yamamoto S, Sueishi M. Sonoporation: Gene transfer using ultrasound. World J Methodol 2013; 3:39-44. [PMID: 25237622 PMCID: PMC4145571 DOI: 10.5662/wjm.v3.i4.39] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2013] [Revised: 12/04/2013] [Accepted: 12/12/2013] [Indexed: 02/06/2023] Open
Abstract
Genes can be transferred using viral or non-viral vectors. Non-viral methods that use plasmid DNA and short interference RNA (siRNA) have advantages, such as low immunogenicity and low likelihood of genomic integration in the host, when compared to viral methods. Non-viral methods have potential merit, but their gene transfer efficiency is not satisfactory. Therefore, new methods should be developed. Low-frequency ultrasound irradiation causes mechanical perturbation of the cell membrane, allowing the uptake of large molecules in the vicinity of the cavitation bubbles. The collapse of these bubbles generates small transient holes in the cell membrane and induces transient membrane permeabilization. This formation of small pores in the cell membrane using ultrasound allows the transfer of DNA/RNA into the cell. This phenomenon is known as sonoporation and is a gene delivery method that shows great promise as a potential new approach in gene therapy. Microbubbles lower the threshold of cavity formation. Complexes of therapeutic genes and microbubbles improve the transfer efficiency of genes. Diagnostic ultrasound is potentially a suitable sonoporator because it allows the real-time monitoring of irradiated fields.
Collapse
Affiliation(s)
- Minoru Tomizawa
- Minoru Tomizawa, Department of Gastroenterology, National Hospital Organization Shimoshizu Hospital, 934-5 Shikawatashi, Yotsukaido City, Chiba 284-0003, Japan
| | - Fuminobu Shinozaki
- Minoru Tomizawa, Department of Gastroenterology, National Hospital Organization Shimoshizu Hospital, 934-5 Shikawatashi, Yotsukaido City, Chiba 284-0003, Japan
| | - Yasufumi Motoyoshi
- Minoru Tomizawa, Department of Gastroenterology, National Hospital Organization Shimoshizu Hospital, 934-5 Shikawatashi, Yotsukaido City, Chiba 284-0003, Japan
| | - Takao Sugiyama
- Minoru Tomizawa, Department of Gastroenterology, National Hospital Organization Shimoshizu Hospital, 934-5 Shikawatashi, Yotsukaido City, Chiba 284-0003, Japan
| | - Shigenori Yamamoto
- Minoru Tomizawa, Department of Gastroenterology, National Hospital Organization Shimoshizu Hospital, 934-5 Shikawatashi, Yotsukaido City, Chiba 284-0003, Japan
| | - Makoto Sueishi
- Minoru Tomizawa, Department of Gastroenterology, National Hospital Organization Shimoshizu Hospital, 934-5 Shikawatashi, Yotsukaido City, Chiba 284-0003, Japan
| |
Collapse
|
40
|
Schade GR, Styn NR, Ives KA, Hall TL, Roberts WW. Prostate histotripsy: evaluation of prostatic urethral treatment parameters in a canine model. BJU Int 2013; 113:498-503. [PMID: 24176120 DOI: 10.1111/bju.12333] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To assess the impact of histotripsy treatment parameters (pulse number and pulse-repetition frequency [PRF]) on the efficiency of histotripsy induced homogenisation of the prostatic urethra. MATERIALS AND METHODS In all, 34 transabdominal prostate histotripsy treatments were applied along a perpendicular plane traversing the prostatic urethra of 21 dogs. Prostate histotripsy was applied with (i) escalating pulse number with fixed PRF or (ii) at fixed pulse number with varying PRFs. The development of urethral homognisation ≤14 days of histotripsy was evaluated endoscopically and confirmed histologically. RESULTS Within 14 days of histotripsy 50%, 83%, 83%, and 100% of dogs receiving 12 500, 25 000, 50 000, and 100 000 pulses/mm of treatment path (delivered at 500 Hz PRF), respectively developed prostatic urethral disintegration. Delivery of 100 000 pulses/mm was required to achieve urethral disintegration in all dogs within 24 h of histotripsy treatment. Increasing histotripsy PRF from 50 to 500 to 2000 Hz while applying a constant dose of 25 000 pulses/mm treatment was associated with increased rate of urethral disintegration (50% vs 75% vs 100% at 14 days, respectively). CONCLUSIONS Increasing the number of histotripsy pulses and/or increasing the PRF of histotripsy treatment applied to the urethra may improve the rate and efficiency of prostatic urethral disintegration in the canine model. This understanding will aid in the development of treatment strategies for prostate histotripsy for benign prostatic hyperplasia in human trials.
Collapse
Affiliation(s)
- George R Schade
- Department of Urology, University of Michigan, Ann Arbor, MI, USA
| | | | | | | | | |
Collapse
|
41
|
Allam CL, Wilkinson JE, Cheng X, Ives KA, Hall TL, Roberts WW. Histotripsy effects on the bladder trigone: functional and histologic consequences in the canine model. J Endourol 2013; 27:1267-71. [PMID: 23731213 DOI: 10.1089/end.2013.0234] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Histotripsy is an extracorporeal therapeutic ultrasound (US) technology, where high-amplitude acoustic energy is applied to targeted tissue. Previous research has demonstrated the feasibility, safety, and effectiveness of histotripsy tissue homogenization and debulking of the prostate in the canine model. Before translating this technology for human use, it is prudent to examine the susceptibility of critical periprostatic structures to cavitation injury in the event of histotripsy mistargeting. In this study, we sought to characterize the tissue effects and biologic response of directly treating the bladder trigone with histotripsy. MATERIALS AND METHODS In eight anesthetized canines, 750,000 histotripsy pulses were applied uniformly across a 2×1.5-cm area encompassing the bladder trigone and ureteral orifices. Prostate and bladder trigone were harvested immediately after treatment (2 subjects) or at 14 days (6 subjects). Flexible cystourethroscopy, US imaging, and creatinine levels were obtained at intervals until harvest, 14 days after treatment. In one control subject, harvested at 2 days, the same treatment algorithm was applied to the prostate. RESULTS Transrectal US imaging revealed a cavitation bubble cloud on the surface of the bladder trigone and progressive development of tissue edema during treatment. Flexible cystourethroscopy immediately after treatment confirmed edema and erythema of the trigone. In the six subjects survived 2 weeks after treatment, one incidence of transient, self-limited ureteral obstruction was noted based on hydronephrosis and creatinine levels. At harvest, ureteral orifices were confirmed patent by passage of a guide wire. Histologic evaluation revealed hemorrhage acutely with mild localized fibrosis at 14 days. CONCLUSIONS In this study, designed along the lines of a worst-case, destructive testing scenario, direct targeting of the bladder trigone with supratherapeutic histotripsy failed to induce significant tissue damage or clinical complication. These results are reassuring and will guide treatment strategy in upcoming human clinical trials of histotripsy treatment for benign prostatic hyperplasia.
Collapse
|
42
|
Zhou Y, Gao XW. Variations of bubble cavitation and temperature elevation during lesion formation by high-intensity focused ultrasound. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 134:1683-1694. [PMID: 23927209 DOI: 10.1121/1.4812895] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
High-intensity focused ultrasound (HIFU) is emerging as an effective therapeutic modality in both thermal ablations for solid tumor/cancer and soft-tissue fragmentation. Mechanical and thermal effects, which play an important role in the HIFU treatment simultaneously, are dependent on the operating parameters and may vary with the progress of therapy. Mechanical erosion in the shape of a "squid," a "dumbbell" lesion with both mechanical and thermal lesions, or a "tadpole" lesion with mechanical erosion at the center and thermal necrosis on the boundary in the transparent gel phantom could be produced correspondingly with the pulse duration of 5-30 ms, which is much longer than histotripsy burst but shorter than the time for tissue boiling, and pulse repetition frequency (PRF) of 0.2-5 Hz. Meanwhile, variations of bubble cavitation (both inertial and stable cavitation) and temperature elevation in the focal region (i.e., z = -2.5, 0, and 2.5 mm) were measured by passive cavitation detection (PCD) and thermocouples during the therapeutic procedure, respectively. Stable cavitation increased with the pulse duration, PRF, and the number of pulses delivered. However, inertial cavitation was found to increase initially and then decrease with long pulse duration and high PRF. Temperature in the pre-focal region is always higher than those at the focal and post-focal position in all tests. Great variations of PCD signals and temperature elevation are due to the generation and persistence of large bubble, which is resistant to collapse and occurs with the increase of pulse duration and PRF. Similar lesion pattern and variations were also observed in ex vivo porcine kidneys. Hyperechoes in the B-mode ultrasound image were comparable to the shape and size of lesions in the dissected tissue. Thermal lesion volume increased with the increase of pulse duration and PRF, but mechanical erosion reached its maximum volume with the pulse duration of 20 ms and PRF of 1 Hz. Altogether, bubble cavitation and thermal field vary with the progress of HIFU treatment with different sonication parameters, which provide insights into the interaction of ultrasound burst with the induced bubbles for both soft tissue fractionation and enhancement in thermal accumulation. Appropriate synergy and monitoring of mechanical and thermal effects would broaden the HIFU application and enhance its efficiency as well as safety.
Collapse
Affiliation(s)
- Yufeng Zhou
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798.
| | | |
Collapse
|
43
|
Xu J, Bigelow TA, Nagaraju R. Precision control of lesions by high-intensity focused ultrasound cavitation-based histotripsy through varying pulse duration. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2013; 60:1401-1411. [PMID: 25004507 DOI: 10.1109/tuffc.2013.2712] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The goal of this experimental study was to explore the feasibility of acquiring controllable precision through varying pulse duration for lesions generated by cavitation-based histotripsy. Histotripsy uses high-intensity focused ultrasound (HIFU) at low duty factor to create energetic bubble clouds inside tissue to liquefy a region. It uses cavitation-mediated mechanical effects while minimizing heating, and has the advantages of real-time monitoring and lesion fidelity to treatment planning. In our study, histotripsy was applied to three groups of tissue-mimicking agar samples of different stiffnesses (29.4 ± 5.3, 44.8 ± 5.9, and 66.4 ± 7.1 kPa). B-mode imaging was used first to quantify bubble cluster dimensions in both water and agar. Then, a 4.5-mm-wide square (lateral to the focal plane) was scanned in a raster pattern with a step size of 0.75 mm in agar histotripsy experiments to estimate equivalent bubble cluster dimensions based on the histotripsyinduced damage. The 15-s exposure at each treatment location comprised 5000 sine-wave tone bursts at a spatial-peak pulseaverage intensity of 41.1 kW/cm2, with peak compressional and rarefactional pressures of 102 and 17 MPa, respectively. The results showed that bubble cluster width and length increased with pulse duration and decreased with agar stiffness. Therefore, a significant improvement in histotripsy precision could be achieved by reducing the pulse duration.
Collapse
|
44
|
Abstract
PURPOSE OF REVIEW Transurethral resection of the prostate has long been held as the gold standard for treatment of benign prostatic hyperplasia (BPH); however, there have been significant innovations in other less invasive alternative treatments for BPH in recent years. Our purpose is to present emerging surgical treatment modalities which have been presented in the last 12 months. RECENT FINDINGS We report recent results in different treatment options for BPH. The concept of stenting the urethra has already been introduced nearly 20 years ago in urology and like intraprostatic injection of botulinum toxin it has found application in urological treatment of bladder outlet obstruction. The prostatic urethral lift procedure is a novel surgical minimal invasive approach needing long-term results. Intraprostatic injections with NX-1207 and histotripsy fractionation of prostate tissue are treatment modalities, which are currently under evaluation for a clinical application in humans. SUMMARY Anaesthesia-free outpatient capability, lack of sexual side-effects and avoidance of actual surgery are attractive to patient and clinician alike. Some of the presented treatments may establish in clinical practice as a suitable treatment alternative to transurethral resection of the prostate and medical therapy.
Collapse
|
45
|
Xu J, Bigelow TA, Lee H. Effect of pulse repetition frequency and scan step size on the dimensions of the lesions formed in agar by HIFU histotripsy. ULTRASONICS 2013; 53:889-896. [PMID: 23339995 DOI: 10.1016/j.ultras.2012.12.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2011] [Revised: 12/18/2012] [Accepted: 12/19/2012] [Indexed: 06/01/2023]
Abstract
Histotripsy uses high-intensity focused ultrasound pulses at low duty cycle to generate energetic bubble clouds inside tissue to fractionate a region. As a potential tumor treatment modality, this cavitation-based non-invasive technique has the advantages of easy monitoring and sharp borders. Aiming at therapy efficiency, we experimentally investigated the effects of pulse repetition frequency (PRF) and lateral scan step size on the dimensions of lesions formed through HIFU histotripsy in agar mimicking tissue in terms of mechanical (not acoustical) properties. The single-element spherically focused source (1.1 MHz, 6.34 cm focal length, f/1) was excited to reach the peak compressional and rarefactional pressures of ~102 and 17 MPa, respectively. A targeted rectangular block of 4.5 mm wide (lateral) and 6mm deep (axial) was scanned in a raster pattern with a constant axial step size of 3mm. The lateral step size was varied between 375, 750, 1500, 2250 and 4500 μm. Pulses at each treatment location consisted of 5000 20-cycle sine wave tone bursts with the PRF of 167, 333 or 1000 Hz. Results suggested that the bubble activity region could extend beyond the -3 dB region and that refining the lateral scan mesh and/or increasing PRF enlarged the lesion extent. The 1500 μm-333 Hz and the 1500 μm-1 kHz conditions were in a more favorable position to be viewed as optimal with regard to lesion volume generation rate, bubble activity region width, and the potential for thermal damage.
Collapse
Affiliation(s)
- Jin Xu
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA
| | | | | |
Collapse
|
46
|
Maxwell AD, Cain CA, Hall TL, Fowlkes JB, Xu Z. Probability of cavitation for single ultrasound pulses applied to tissues and tissue-mimicking materials. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:449-65. [PMID: 23380152 PMCID: PMC3570716 DOI: 10.1016/j.ultrasmedbio.2012.09.004] [Citation(s) in RCA: 198] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2012] [Revised: 06/12/2012] [Accepted: 09/05/2012] [Indexed: 05/04/2023]
Abstract
In this study, the negative pressure values at which inertial cavitation consistently occurs in response to a single, two-cycle, focused ultrasound pulse were measured in several media relevant to cavitation-based ultrasound therapy. The pulse was focused into a chamber containing one of the media, which included liquids, tissue-mimicking materials, and ex vivo canine tissue. Focal waveforms were measured by two separate techniques using a fiber-optic hydrophone. Inertial cavitation was identified by high-speed photography in optically transparent media and an acoustic passive cavitation detector. The probability of cavitation (P(cav)) for a single pulse as a function of peak negative pressure (p(-)) followed a sigmoid curve, with the probability approaching one when the pressure amplitude was sufficient. The statistical threshold (defined as P(cav) = 0.5) was between p(-) = 26 and 30 MPa in all samples with high water content but varied between p(-) = 13.7 and >36 MPa in other media. A model for radial cavitation bubble dynamics was employed to evaluate the behavior of cavitation nuclei at these pressure levels. A single bubble nucleus with an inertial cavitation threshold of p(-) = 28.2 megapascals was estimated to have a 2.5 nm radius in distilled water. These data may be valuable for cavitation-based ultrasound therapy to predict the likelihood of cavitation at various pressure levels and dimensions of cavitation-induced lesions in tissue.
Collapse
Affiliation(s)
- Adam D Maxwell
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
| | | | | | | | | |
Collapse
|
47
|
Xu J, Bigelow TA, Riesberg GM. Impact of preconditioning pulse on lesion formation during high-intensity focused ultrasound histotripsy. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1918-1929. [PMID: 22929656 DOI: 10.1016/j.ultrasmedbio.2012.06.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2012] [Revised: 06/11/2012] [Accepted: 06/25/2012] [Indexed: 06/01/2023]
Abstract
Therapeutic applications with high-intensity focused ultrasound (HIFU) fall into two classifications-one using thermal effect for coagulation or ablation while generally avoiding cavitation and the other using cavitation-mediated mechanical effects while suppressing heating. Representative of the latter, histotripsy uses HIFU at low duty factor to create energetic bubble clouds inside tissue to liquefy a region and has the advantages in real-time monitoring and lesion fidelity to treatment planning. We explored the impact of a preconditioning/heating pulse on histotripsy lesion formation in porcine muscle samples. During sonication, a targeted square region 9 mm wide (lateral to the focal plane) was scanned in a raster pattern with a step size of 0.75 mm. The 20-s exposure at each treatment location consisted of a 5-s duration preconditioning burst at spatial-peak intensities from 0-1386 W/cm² followed by 5000 tone bursts at high intensity (with spatial-peak pulse-average intensity of 47.34 kW/cm², spatial-peak temporal-average intensity of 284 W/cm², peak compressional pressure of 102 MPa and peak rarefactional pressure of 17 MPa). The temperature increase for all exposures was measured using a thermal imager immediately after each exposure. Lesion volume increased with increasing amplitude of the preconditioning pulse until coagulation was observed, but lesion width/area did not change significantly with the amplitude. In addition, the lesion dimensions became smaller when the global tissue temperature was raised before applying the histotripsy pulsing sequence. Therefore, the benefit of the preconditioning pulse was not caused by global heating.
Collapse
Affiliation(s)
- Jin Xu
- Department of Mechanical Engineering, Iowa State University, Ames, IA, USA
| | | | | |
Collapse
|
48
|
Schade GR, Keller J, Ives K, Cheng X, Rosol TJ, Keller E, Roberts WW. Histotripsy focal ablation of implanted prostate tumor in an ACE-1 canine cancer model. J Urol 2012; 188:1957-64. [PMID: 22999534 DOI: 10.1016/j.juro.2012.07.006] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2012] [Indexed: 10/27/2022]
Abstract
PURPOSE Histotripsy is a nonthermal ablative focused ultrasound technology with possible future applications for prostate cancer focal therapy. We used the ACE-1 prostate tumor model and evaluated the feasibility of treating prostate tumors with histotripsy. MATERIALS AND METHODS A total of 10 immunosuppressed (cyclosporine treated) canine subjects received transrectal ultrasound guided percutaneous intraprostatic injection of ACE-1 canine prostate cancer cells. Prostates were serially imaged with transrectal ultrasound to monitor tumor growth. Subjects were sham treated (3) or underwent transabdominal histotripsy of the prostate, which targeted implanted tumor and adjacent parenchyma using a 750 kHz piezoelectric ultrasound therapy transducer. Prostates were examined histologically to confirm tumor and the histotripsy treatment effect. RESULTS ACE-1 tumors were visualized on transrectal ultrasound in all 10 subjects within 2 weeks of tumor injection. Lesions demonstrated growth in the prostatic capsule, glandular lobules, fibrous septa and periurethral stroma with significant desmoplastic reaction and areas of central necrosis on histology. Lymph node and/or pulmonary metastases developed in 4 subjects. Ultrasound tumor localization and initiation of cavitation during histotripsy therapy were feasible in all treated subjects. Histologically there was evidence of homogenization of tumor and prostatic parenchyma in all 4 acute subjects with necrosis and hemorrhage in the 3 chronic subjects. CONCLUSIONS This study shows the feasibility of histotripsy destruction of prostate tumors in a canine ACE-1 model. It suggests a potential role for histotripsy based focal therapy for prostate cancer. Further studies are needed to better characterize the effects of histotripsy on malignant tissues.
Collapse
Affiliation(s)
- George R Schade
- Department of Urology, University of Michigan, Ann Arbor, Michigan 48109, USA
| | | | | | | | | | | | | |
Collapse
|
49
|
Styn NR, Hall TL, Fowlkes JB, Cain CA, Roberts WW. Histotripsy of Renal Implanted VX-2 Tumor in a Rabbit Model: Investigation of Metastases. Urology 2012; 80:724-9. [DOI: 10.1016/j.urology.2012.06.020] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2012] [Revised: 05/11/2012] [Accepted: 06/12/2012] [Indexed: 12/01/2022]
|
50
|
Schade GR, Hall TL, Roberts WW. Urethral-sparing histotripsy of the prostate in a canine model. Urology 2012; 80:730-5. [PMID: 22840869 DOI: 10.1016/j.urology.2012.05.027] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2012] [Revised: 04/18/2012] [Accepted: 05/19/2012] [Indexed: 11/19/2022]
Abstract
OBJECTIVE To evaluate the feasibility and healing response to urethral-sparing prostate histotripsy using a canine model of benign prostatic hypertrophy. METHODS Histotripsy was performed on 10 canines using a 750-kHz piezoelectric ultrasound transducer targeting the prostatic parenchyma while avoiding the urethra. Periprocedure prostatic urethral integrity was evaluated with serial cystourethroscopy. Evolution of histotripsy treatment effect and subjects' response to urethral sparing was evaluated with serial ultrasound and laboratory evaluation, respectively. The dogs were euthanized acutely or chronically and findings were confirmed histologically. RESULTS Bilateral treatment was possible in 8/10 subjects, whereas unilateral treatment was performed in 2/10. Failure to spare the urethra was observed in 2/18 treatments-one acutely and one chronically, despite normal cystourethroscopy for the first week. Modest prostatic volume reduction was seen in subjects survived to 8 weeks post histotripsy. Laboratory studies revealed transient perioperative increases in mean white blood cell count, C-reactive protein, and lactate dehydrogenase. On histology, 80% of successful urethral sparing treatment cavities were completely epithelialized, containing simple fluid with minimal cellular debris at 8 weeks despite no communication with the urethra. CONCLUSION Urethral-sparing histotripsy of the prostate is feasible and well tolerated in a canine model, resulting in modest volume reduction and prompt resorption of homogenized tissue debris. Human studies to evaluate the clinical utility and symptomatic response of urethral sparing are needed.
Collapse
Affiliation(s)
- George R Schade
- Department of Urology, University of Michigan, Ann Arbor, MI 48109, USA
| | | | | |
Collapse
|