1
|
Hou Y, Nanduri D, Granley J, Weiland JD, Beyeler M. Axonal stimulation affects the linear summation of single-point perception in three Argus II users. J Neural Eng 2024; 21:026031. [PMID: 38457841 PMCID: PMC11003296 DOI: 10.1088/1741-2552/ad31c4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 02/20/2024] [Accepted: 03/08/2024] [Indexed: 03/10/2024]
Abstract
Objective.Retinal implants use electrical stimulation to elicit perceived flashes of light ('phosphenes'). Single-electrode phosphene shape has been shown to vary systematically with stimulus parameters and the retinal location of the stimulating electrode, due to incidental activation of passing nerve fiber bundles. However, this knowledge has yet to be extended to paired-electrode stimulation.Approach.We retrospectively analyzed 3548 phosphene drawings made by three blind participants implanted with an Argus II Retinal Prosthesis. Phosphene shape (characterized by area, perimeter, major and minor axis length) and number of perceived phosphenes were averaged across trials and correlated with the corresponding single-electrode parameters. In addition, the number of phosphenes was correlated with stimulus amplitude and neuroanatomical parameters: electrode-retina and electrode-fovea distance as well as the electrode-electrode distance to ('between-axon') and along axon bundles ('along-axon'). Statistical analyses were conducted using linear regression and partial correlation analysis.Main results.Simple regression revealed that each paired-electrode shape descriptor could be predicted by the sum of the two corresponding single-electrode shape descriptors (p < .001). Multiple regression revealed that paired-electrode phosphene shape was primarily predicted by stimulus amplitude and electrode-fovea distance (p < .05). Interestingly, the number of elicited phosphenes tended to increase with between-axon distance (p < .05), but not with along-axon distance, in two out of three participants.Significance.The shape of phosphenes elicited by paired-electrode stimulation was well predicted by the shape of their corresponding single-electrode phosphenes, suggesting that two-point perception can be expressed as the linear summation of single-point perception. The impact of the between-axon distance on the perceived number of phosphenes provides further evidence in support of the axon map model for epiretinal stimulation. These findings contribute to the growing literature on phosphene perception and have important implications for the design of future retinal prostheses.
Collapse
Affiliation(s)
- Yuchen Hou
- Department of Computer Science, University of California, Santa Barbara, CA, United States of America
- Department of Psychological & Brain Sciences, University of California, Santa Barbara, CA, United States of America
| | - Devyani Nanduri
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America
| | - Jacob Granley
- Department of Computer Science, University of California, Santa Barbara, CA, United States of America
| | - James D Weiland
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States of America
| | - Michael Beyeler
- Department of Computer Science, University of California, Santa Barbara, CA, United States of America
- Department of Psychological & Brain Sciences, University of California, Santa Barbara, CA, United States of America
| |
Collapse
|
2
|
Hou Y, Nanduri D, Granley J, Weiland JD, Beyeler M. Axonal stimulation affects the linear summation of single-point perception in three Argus II users. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.07.21.23292908. [PMID: 37546858 PMCID: PMC10402233 DOI: 10.1101/2023.07.21.23292908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
Purpose Retinal implants use electrical stimulation to elicit perceived flashes of light ("phosphenes"). Single-electrode phosphene shape has been shown to vary systematically with stimulus parameters and the retinal location of the stimulating electrode, due to incidental activation of passing nerve fiber bundles. However, this knowledge has yet to be extended to paired-electrode stimulation. Methods We retrospectively analyzed 3548 phosphene drawings made by three blind participants implanted with an Argus II Retinal Prosthesis. Phosphene shape (characterized by area, perimeter, major and minor axis length) and number of perceived phosphenes were averaged across trials and correlated with the corresponding single-electrode parameters. In addition, the number of phosphenes was correlated with stimulus amplitude and neuroanatomical parameters: electrode-retina and electrode-fovea distance as well as the electrode-electrode distance to ("between-axon") and along axon bundles ("along-axon"). Statistical analyses were conducted using linear regression and partial correlation analysis. Results Simple regression revealed that each paired-electrode shape descriptor could be predicted by the sum of the two corresponding single-electrode shape descriptors (p < .001). Multiple regression revealed that paired-electrode phosphene shape was primarily predicted by stimulus amplitude and electrode-fovea distance (p < .05). Interestingly, the number of elicited phosphenes tended to increase with between-axon distance (p < .05), but not with along-axon distance, in two out of three participants. Conclusions The shape of phosphenes elicited by paired-electrode stimulation was well predicted by the shape of their corresponding single-electrode phosphenes, suggesting that two-point perception can be expressed as the linear summation of single-point perception. The notable impact of the between-axon distance on the perceived number of phosphenes provides further evidence in support of the axon map model for epiretinal stimulation. These findings contribute to the growing literature on phosphene perception and have important implications for the design of future retinal prostheses.
Collapse
Affiliation(s)
- Yuchen Hou
- Department of Computer Science, University of California, Santa Barbara, CA
- Department of Psychological & Brain Sciences, University of California, Santa Barbara, CA
| | - Devyani Nanduri
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI
| | - Jacob Granley
- Department of Computer Science, University of California, Santa Barbara, CA
| | - James D Weiland
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI
| | - Michael Beyeler
- Department of Computer Science, University of California, Santa Barbara, CA
- Department of Psychological & Brain Sciences, University of California, Santa Barbara, CA
| |
Collapse
|
3
|
Yang R, Zhao P, Wang L, Feng C, Peng C, Wang Z, Zhang Y, Shen M, Shi K, Weng S, Dong C, Zeng F, Zhang T, Chen X, Wang S, Wang Y, Luo Y, Chen Q, Chen Y, Jiang C, Jia S, Yu Z, Liu J, Wang F, Jiang S, Xu W, Li L, Wang G, Mo X, Zheng G, Chen A, Zhou X, Jiang C, Yuan Y, Yan B, Zhang J. Assessment of visual function in blind mice and monkeys with subretinally implanted nanowire arrays as artificial photoreceptors. Nat Biomed Eng 2023:10.1038/s41551-023-01137-8. [PMID: 37996614 DOI: 10.1038/s41551-023-01137-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Accepted: 10/17/2023] [Indexed: 11/25/2023]
Abstract
Retinal prostheses could restore image-forming vision in conditions of photoreceptor degeneration. However, contrast sensitivity and visual acuity are often insufficient. Here we report the performance, in mice and monkeys with induced photoreceptor degeneration, of subretinally implanted gold-nanoparticle-coated titania nanowire arrays providing a spatial resolution of 77.5 μm and a temporal resolution of 3.92 Hz in ex vivo retinas (as determined by patch-clamp recording of retinal ganglion cells). In blind mice, the arrays allowed for the detection of drifting gratings and flashing objects at light-intensity thresholds of 15.70-18.09 μW mm-2, and offered visual acuities of 0.3-0.4 cycles per degree, as determined by recordings of visually evoked potentials and optomotor-response tests. In monkeys, the arrays were stable for 54 weeks, allowed for the detection of a 10-μW mm-2 beam of light (0.5° in beam angle) in visually guided saccade experiments, and induced plastic changes in the primary visual cortex, as indicated by long-term in vivo calcium imaging. Nanomaterials as artificial photoreceptors may ameliorate visual deficits in patients with photoreceptor degeneration.
Collapse
Affiliation(s)
- Ruyi Yang
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Peng Zhao
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Liyang Wang
- Department of Ophthalmology, Zhongshan Hospital, Fudan University, Shanghai, P. R. China
| | - Chenli Feng
- Department of Ophthalmology, Zhongshan Hospital, Fudan University, Shanghai, P. R. China
| | - Chen Peng
- Laboratory of Advanced Materials, Department of Chemistry, Fudan University, Shanghai, P. R. China
| | - Zhexuan Wang
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Yingying Zhang
- Key Laboratory of Brain Functional Genomics (Ministry of Education), East China Normal University, Shanghai, P. R. China
| | - Minqian Shen
- Department of Ophthalmology, Zhongshan Hospital, Fudan University, Shanghai, P. R. China
| | - Kaiwen Shi
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Shijun Weng
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Chunqiong Dong
- Department of Ophthalmology, Zhongshan Hospital, Fudan University, Shanghai, P. R. China
| | - Fu Zeng
- Key Laboratory of Brain Functional Genomics (Ministry of Education), East China Normal University, Shanghai, P. R. China
| | - Tianyun Zhang
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Xingdong Chen
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Shuiyuan Wang
- Shanghai Key Lab for Future Computing Hardware and System, School of Microelectronics, Fudan University, Shanghai, P. R. China
| | - Yiheng Wang
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Yuanyuan Luo
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Qingyuan Chen
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Yuqing Chen
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Chengyong Jiang
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Shanshan Jia
- School of Computer Science, Institute for Artificial Intelligence, Peking University, Beijing, P.R. China
| | - Zhaofei Yu
- School of Computer Science, Institute for Artificial Intelligence, Peking University, Beijing, P.R. China
| | - Jian Liu
- School of Computer Science, University of Birmingham, Birmingham, UK
| | - Fei Wang
- Department of Hand Surgery, the National Clinical Research Center for Aging and Medicine, Huashan Hospital, Fudan University, Shanghai, P. R. China
| | - Su Jiang
- Department of Hand Surgery, the National Clinical Research Center for Aging and Medicine, Huashan Hospital, Fudan University, Shanghai, P. R. China
| | - Wendong Xu
- Department of Hand Surgery, the National Clinical Research Center for Aging and Medicine, Huashan Hospital, Fudan University, Shanghai, P. R. China
- Department of Hand and Upper Extremity Surgery, Jing'an District Central Hospital, Fudan University, Shanghai, P.R. China
| | - Liang Li
- Center of Brain Sciences, Beijing Institute of Basic Medical Sciences, Beijing, P. R. China
| | - Gang Wang
- Center of Brain Sciences, Beijing Institute of Basic Medical Sciences, Beijing, P. R. China
| | - Xiaofen Mo
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Gengfeng Zheng
- Laboratory of Advanced Materials, Department of Chemistry, Fudan University, Shanghai, P. R. China
| | - Aihua Chen
- Key Laboratory of Brain Functional Genomics (Ministry of Education), East China Normal University, Shanghai, P. R. China
| | - Xingtao Zhou
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China
| | - Chunhui Jiang
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China.
| | - Yuanzhi Yuan
- Department of Ophthalmology, Zhongshan Hospital, Fudan University, Shanghai, P. R. China.
- Zhongshan Hospital (Xiamen), Fudan University, Xiamen, P.R. China.
| | - Biao Yan
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China.
| | - Jiayi Zhang
- State Key Laboratory of Medical Neurobiology, MOE Frontiers Center for Brain Science, Institutes of Brain Science, Institute for Medical and Engineering Innovation, Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, P. R. China.
| |
Collapse
|
4
|
Moorthy VM, Rathnasami JD, Srivastava VM. Design Optimization and Characterization with Fabrication of Nanomaterials-Based Photo Diode Cell for Subretinal Implant Application. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:934. [PMID: 36903812 PMCID: PMC10005570 DOI: 10.3390/nano13050934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 02/28/2023] [Accepted: 03/02/2023] [Indexed: 06/18/2023]
Abstract
An ultrathin nano photodiode array fabricated in a flexible substrate can be an ideal therapeutic replacement for degenerated photoreceptor cells damaged by Age-related Macula Degeneration (AMD) and Retinitis Pigmentosa (RP), such as retinal infections. Silicon-based photodiode arrays have been attempted as artificial retinas. Considering the difficulties caused by hard silicon subretinal implants, researchers have diverted their attention towards organic photovoltaic cells-based subretinal implants. Indium-Tin Oxide (ITO) has been a favorite choice as an anode electrode. A mix of poly(3-hexylthiophene) and [6,6]-phenyl C61-butyric acid methyleste (P3HT: PCBM) has been utilized as an active layer in such nanomaterial-based subretinal implants. Though encouraging results have been obtained during the trial of such retinal implants, the need to replace ITO with a suitable transparent conductive electrode will be a suitable substitute. Further, conjugated polymers have been used as active layers in such photodiodes and have shown delamination in the retinal space over time despite their biocompatibility. This research attempted to fabricate and characterize Bulk Hetero Junction (BHJ) based Nano Photo Diode (NPD) utilizing Graphene-polyethylene terephthalate (G-PET)/semiconducting Single-Wall Carbon Nano Tubes (s-SWCNT): fullerene (C60) blend/aluminium (Al) structure to determine the issues in the development of subretinal prosthesis. An effective design approach adopted in this analysis has resulted in developing an NPD with an Efficiency of 10.1% in a non-ITO-driven NPD structure. Additionally, the results show that the efficiency can be further improved by increasing active layer thickness.
Collapse
Affiliation(s)
- Vijai M. Moorthy
- Department of Electronic Engineering, Howard College, University of KwaZulu-Natal, Durban 4041, South Africa
| | - Joseph D. Rathnasami
- Department of Electronics and Instrumentation Engineering, Faculty of Engineering and Technology, Annamalai University, Chidambaram 608 002, India
| | - Viranjay M. Srivastava
- Department of Electronic Engineering, Howard College, University of KwaZulu-Natal, Durban 4041, South Africa
| |
Collapse
|
5
|
Flexible ultrasound-induced retinal stimulating piezo-arrays for biomimetic visual prostheses. Nat Commun 2022; 13:3853. [PMID: 35788594 PMCID: PMC9253314 DOI: 10.1038/s41467-022-31599-4] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Accepted: 06/22/2022] [Indexed: 12/29/2022] Open
Abstract
Electronic visual prostheses, or biomimetic eyes, have shown the feasibility of restoring functional vision in the blind through electrical pulses to initiate neural responses artificially. However, existing visual prostheses predominantly use wired connections or electromagnetic waves for powering and data telemetry, which raises safety concerns or couples inefficiently to miniaturized implant units. Here, we present a flexible ultrasound-induced retinal stimulating piezo-array that can offer an alternative wireless artificial retinal prosthesis approach for evoking visual percepts in blind individuals. The device integrates a two-dimensional piezo-array with 32-pixel stimulating electrodes in a flexible printed circuit board. Each piezo-element can be ultrasonically and individually activated, thus, spatially reconfigurable electronic patterns can be dynamically applied via programmable ultrasound beamlines. As a proof of concept, we demonstrate the ultrasound-induced pattern reconstruction in ex vivo murine retinal tissue, showing the potential of this approach to restore functional, life-enhancing vision in people living with blindness.
Collapse
|
6
|
Italiano ML, Guo T, Lovell NH, Tsai D. Improving the spatial resolution of artificial vision using midget retinal ganglion cell populations modelled at the human fovea. J Neural Eng 2022; 19. [PMID: 35609556 DOI: 10.1088/1741-2552/ac72c2] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 05/24/2022] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Retinal prostheses seek to create artificial vision by stimulating surviving retinal neurons of patients with profound vision impairment. Notwithstanding tremendous research efforts, the performance of all implants tested to date has remained rudimentary, incapable of overcoming the threshold for legal blindness. To maximize the perceptual efficacy of retinal prostheses, a device must be capable of controlling retinal neurons with greater spatiotemporal precision. Most studies of retinal stimulation were derived from either non-primate species or the peripheral primate retina. We investigated if artificial stimulation could leverage the high spatial resolution afforded by the neural substrates at the primate fovea and surrounding regions to achieve improved percept qualities. APPROACH We began by developing a new computational model capable of generating anatomically accurate retinal ganglion cell (RGC) populations within the human central retina. Next, multiple RGC populations across the central retina were stimulated in-silico to compare clinical and recently proposed neurostimulation configurations based on their ability to improve perceptual efficacy and reduce activation thresholds. MAIN RESULTS Our model uniquely upholds eccentricity-dependent characteristics such as RGC density and dendritic field diameter, whilst incorporating anatomically accurate features such as axon projection and three-dimensional RGC layering, features often forgone in favor of reduced computational complexity. Following epiretinal stimulation, the RGCs in our model produced response patterns in shapes akin to the complex percepts reported in clinical trials. Our results also demonstrated that even within the neuron-dense central retina, epiretinal stimulation using a multi-return hexapolar electrode arrangement could reliably achieve spatially focused RGC activation and could achieve single-cell excitation in 74% of all tested locations. SIGNIFICANCE This study establishes an anatomically accurate three-dimensional model of the human central retina and demonstrates the potential for an epiretinal hexapolar configuration to achieve consistent, spatially confined retinal responses, even within the neuron-dense foveal region. Our results promote the prospect and optimization of higher spatial resolution in future epiretinal implants.
Collapse
Affiliation(s)
- Michael Lewis Italiano
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Sydney, New South Wales, 2052, AUSTRALIA
| | - Tianruo Guo
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Sydney, New South Wales, 2052, AUSTRALIA
| | - Nigel H Lovell
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Sydney, New South Wales, 2052, AUSTRALIA
| | - David Tsai
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Sydney, New South Wales, 2052, AUSTRALIA
| |
Collapse
|
7
|
Avraham D, Yitzhaky Y. Simulating the perceptual effects of electrode-retina distance in prosthetic vision. J Neural Eng 2022; 19. [PMID: 35561665 DOI: 10.1088/1741-2552/ac6f82] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2022] [Accepted: 05/13/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Retinal prostheses aim to restore some vision in retinitis pigmentosa and age-related macular degeneration blind patients. Many spatial and temporal aspects have been found to affect prosthetic vision. Our objective is to study the impact of the space-variant distance between the stimulating electrodes and the surface of the retina on prosthetic vision and how to mitigate this impact. APPROACH A prosthetic vision simulation was built to demonstrate the perceptual effects of the electrode-retina distance (ERD) with different random spatial variations, such as size, brightness, shape, dropout, and spatial shifts. Three approaches for reducing the ERD effects are demonstrated: electrode grouping (quads), ERD-based input-image enhancement, and object scanning with and without phosphene persistence. A quantitative assessment for the first two approaches was done based on experiments with 20 subjects and three vision-based computational image similarity metrics. MAIN RESULTS The effects of various ERDs on phosphenes' size, brightness, and shape were simulated. Quads, chosen according to the ERDs, effectively elicit phosphenes without exceeding the safe charge density limit, whereas single electrodes with large ERD cannot do so. Input-image enhancement reduced the ERD effects effectively. These two approaches significantly improved ERD-affected prosthetic vision according to the experiment and image similarity metrics. A further reduction of the ERD effects was achieved by scanning an object while moving the head. SIGNIFICANCE ERD has multiple effects on perception with retinal prostheses. One of them is vision loss caused by the incapability of electrodes with large ERD to evoke phosphenes. The three approaches presented in this study can be used separately or together to mitigate the impact of ERD. A consideration of our approaches in reducing the perceptual effects of the ERD may help improve the perception with current prosthetic technology and influence the design of future prostheses.
Collapse
Affiliation(s)
- David Avraham
- Department of Electro-Optical Engineering, Ben-Gurion University of the Negev, 1 Ben-Gurion Blvd., Beer-Sheva, 84105, ISRAEL
| | - Yitzhak Yitzhaky
- Electro-Optical Engineering, School of Engineering, Ben-Gurion University of the Negev, 1 Ben-Gurion Blvd., Beer-Sheva, Southern, 84105, ISRAEL
| |
Collapse
|
8
|
Salas MA, Bell J, Niketeghad S, Oswalt D, Bosking W, Patel U, Dorn JD, Yoshor D, Greenberg R, Bari A, Pouratian N. Sequence of visual cortex stimulation affects phosphene brightness in blind subjects. Brain Stimul 2022; 15:605-614. [DOI: 10.1016/j.brs.2022.03.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 03/12/2022] [Accepted: 03/29/2022] [Indexed: 11/02/2022] Open
|
9
|
Song X, Qiu S, Shivdasani MN, Zhou F, Liu Z, Ma S, Chai X, Chen Y, Cai X, Guo T, Li L. An in-silico analysis of electrically-evoked responses of midget and parasol retinal ganglion cells in different retinal regions. J Neural Eng 2022; 19. [PMID: 35255486 DOI: 10.1088/1741-2552/ac5b18] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Accepted: 03/07/2022] [Indexed: 11/12/2022]
Abstract
BACKGROUND Visual outcomes provided by present retinal prostheses that primarily target retinal ganglion cells (RGCs) through epiretinal stimulation remain rudimentary, partly due to the limited knowledge of retinal responses under electrical stimulation. Better understanding of how different retinal regions can be quantitatively controlled with high spatial accuracy, will be beneficial to the design of micro-electrode arrays (MEAs) and stimulation strategies for next-generation wide-view, high-resolution epiretinal implants. METHODS A computational model was developed to assess neural activity at different eccentricities (2 mm and 5 mm) within the human retina. This model included midget and parasol RGCs with anatomically accurate cell distribution and cell-specific morphological information. We then performed in silico investigations of region-specific RGC responses to epiretinal electrical stimulation using varied electrode sizes (5 µm - 210 µm diameter), emulating both commercialized retinal implants and recently-developed prototype devices. RESULTS Our model of epiretinal stimulation predicted RGC population excitation analogous to the complex percepts reported in human subjects. Following this, our simulations suggest that midget and parasol RGCs have characteristic regional differences in excitation under preferred electrode sizes. Relatively central (2 mm) regions demonstrated higher number of excited RGCs but lower overall activated receptive field (RF) areas under the same stimulus amplitudes (two-way ANOVA, p < 0.05). Furthermore, the activated RGC numbers per unit active RF area (number-RF ratio) were significantly higher in central than in peripheral regions, and higher in the midget than in the parasol population under all tested electrode sizes (two-way ANOVA, p < 0.05). Our simulations also suggested that smaller electrodes exhibit a higher range of controllable stimulation parameters to achieve pre-defined performance of RGC excitation. ..
Collapse
Affiliation(s)
- Xiaoyu Song
- , Shanghai Jiao Tong University, Dongchuan Road, Shanghai Minhang District No. 800, Shanghai, 200240, CHINA
| | - Shirong Qiu
- Shanghai Jiao Tong University, Dongchuan Road, Shanghai Minhang District No. 800, Shanghai, 200240, CHINA
| | - Mohit N Shivdasani
- Graduate School of Biomedical Engineering, University of New South Wales, Lower Ground, Samuels Building (F25), Kensington, New South Wales, 2052, AUSTRALIA
| | - Feng Zhou
- Shanghai Jiao Tong University, Dongchuan Road, Shanghai Minhang District No. 800, Shanghai, 200240, CHINA
| | - Zhengyang Liu
- Shanghai Jiao Tong University, Dongchuan Road, Shanghai Minhang District No. 800, Shanghai, 200240, CHINA
| | - Saidong Ma
- Shanghai Jiao Tong University, Dongchuan Road, Shanghai Minhang District No. 800, Shanghai, 200240, CHINA
| | - Xinyu Chai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, Shanghai, 200240, CHINA
| | - Yao Chen
- Department of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200040, Shanghai, 200240, CHINA
| | - Xuan Cai
- Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai, Shanghai, 200233, CHINA
| | - Tianruo Guo
- the University of New South Wales, Lower Ground, Samuels Building (F25), Sydney, 2052, AUSTRALIA
| | - Liming Li
- Shanghai Jiao Tong University, Dongchuan Road, Shanghai Minhang District No. 800, Shanghai, 200240, CHINA
| |
Collapse
|
10
|
Xu Y, Pang S. Microelectrode Array With Integrated Pneumatic Channels for Dynamic Control of Electrode Position in Retinal Implants. IEEE Trans Neural Syst Rehabil Eng 2021; 29:2292-2298. [PMID: 34705653 DOI: 10.1109/tnsre.2021.3123754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Retinal prostheses are biomedical devices that directly utilize electrical stimulation to create an artificial vision to help patients with retinal diseases such as retinitis pigmentosa. A major challenge in the microelectrode array (MEA) design for retinal prosthesis is to have a close topographical fit on the retinal surface. The local retinal topography can cause the electrodes in certain areas to have gaps up to several hundred micrometers from the retinal surface, resulting in impaired, or totally lost electrode functions in specific areas of the MEA. In this manuscript, an MEA with dynamically controlled electrode positions was proposed to reduce the electrode-retina distance and eliminate areas with poor contact after implantation. The MEA prototype had a polydimethylsiloxane and polyimide hybrid flexible substrate with gold interconnect lines and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate electrodes. Ring shaped counter electrodes were placed around the main electrodes to measure the distance between the electrode and the model retinal surface in real time. The results showed that this MEA design could reduce electrode-retina distance up to [Formula: see text] with 200 kPa pressure. Meanwhile, the impedance between the main and counter electrodes increased with smaller electrode-model retinal surface distance. Thus, the change of electrode-counter electrode impedance could be used to measure the separation gap and to confirm successful electrode contact without the need of optical coherence tomography scan. The amplitude of the stimulation signal on the model retinal surface with originally poor contact could be significantly improved after pressure was applied to reduce the gap.
Collapse
|
11
|
Moleirinho S, Whalen AJ, Fried SI, Pezaris JS. The impact of synchronous versus asynchronous electrical stimulation in artificial vision. J Neural Eng 2021; 18. [PMID: 33900206 DOI: 10.1088/1741-2552/abecf1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Accepted: 03/09/2021] [Indexed: 11/12/2022]
Abstract
Visual prosthesis devices designed to restore sight to the blind have been under development in the laboratory for several decades. Clinical translation continues to be challenging, due in part to gaps in our understanding of critical parameters such as how phosphenes, the electrically-generated pixels of artificial vision, can be combined to form images. In this review we explore the effects that synchronous and asynchronous electrical stimulation across multiple electrodes have in evoking phosphenes. Understanding how electrical patterns influence phosphene generation to control object binding and perception of visual form is fundamental to creation of a clinically successful prosthesis.
Collapse
Affiliation(s)
- Susana Moleirinho
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America
| | - Andrew J Whalen
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America
| | - Shelley I Fried
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America.,Boston VA Healthcare System, Boston, MA, United States of America
| | - John S Pezaris
- Department of Neurosurgery, Massachusetts General Hospital, Boston, MA, United States of America.,Department of Neurosurgery, Harvard Medical School, Boston, MA, United States of America
| |
Collapse
|
12
|
Abbasi B, Rizzo JF. Advances in Neuroscience, Not Devices, Will Determine the Effectiveness of Visual Prostheses. Semin Ophthalmol 2021; 36:168-175. [PMID: 33734937 DOI: 10.1080/08820538.2021.1887902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Background: Innovations in engineering and neuroscience have enabled the development of sophisticated visual prosthetic devices. In clinical trials, these devices have provided visual acuities as high as 20/460, enabled coarse navigation, and even allowed for reading of short words. However, long-term commercial viability arguably rests on attaining even better vision and more definitive improvements in tasks of daily living and quality of life. Purpose: Here we review technological and biological obstacles in the implementation of visual prosthetics. Conclusions: Research in the visual prosthetic field has tackled significant technical challenges, including biocompatibility, signal spread through neural tissue, and inadvertent activation of passing axons; however, significant gaps in knowledge remain in the realm of neuroscience, including the neural code of vision and visual plasticity. We assert that further optimization of prosthetic devices alone will not provide markedly improved visual outcomes without significant advances in our understanding of neuroscience.
Collapse
Affiliation(s)
- Bardia Abbasi
- Neuro-Ophthalmology Service, Department of Ophthalmology, Massachusetts Eye and Ear and Harvard Medical School, Boston, MA, USA
| | - Joseph F Rizzo
- Neuro-Ophthalmology Service, Department of Ophthalmology, Massachusetts Eye and Ear and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
13
|
Gauvain G, Akolkar H, Chaffiol A, Arcizet F, Khoei MA, Desrosiers M, Jaillard C, Caplette R, Marre O, Bertin S, Fovet CM, Demilly J, Forster V, Brazhnikova E, Hantraye P, Pouget P, Douar A, Pruneau D, Chavas J, Sahel JA, Dalkara D, Duebel J, Benosman R, Picaud S. Optogenetic therapy: high spatiotemporal resolution and pattern discrimination compatible with vision restoration in non-human primates. Commun Biol 2021; 4:125. [PMID: 33504896 PMCID: PMC7840970 DOI: 10.1038/s42003-020-01594-w] [Citation(s) in RCA: 52] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Accepted: 12/09/2020] [Indexed: 01/06/2023] Open
Abstract
Vision restoration is an ideal medical application for optogenetics, because the eye provides direct optical access to the retina for stimulation. Optogenetic therapy could be used for diseases involving photoreceptor degeneration, such as retinitis pigmentosa or age-related macular degeneration. We describe here the selection, in non-human primates, of a specific optogenetic construct currently tested in a clinical trial. We used the microbial opsin ChrimsonR, and showed that the AAV2.7m8 vector had a higher transfection efficiency than AAV2 in retinal ganglion cells (RGCs) and that ChrimsonR fused to tdTomato (ChR-tdT) was expressed more efficiently than ChrimsonR. Light at 600 nm activated RGCs transfected with AAV2.7m8 ChR-tdT, from an irradiance of 1015 photons.cm−2.s−1. Vector doses of 5 × 1010 and 5 × 1011 vg/eye transfected up to 7000 RGCs/mm2 in the perifovea, with no significant immune reaction. We recorded RGC responses from a stimulus duration of 1 ms upwards. When using the recorded activity to decode stimulus information, we obtained an estimated visual acuity of 20/249, above the level of legal blindness (20/400). These results lay the groundwork for the ongoing clinical trial with the AAV2.7m8 - ChR-tdT vector for vision restoration in patients with retinitis pigmentosa. Gauvain et al demonstrate that optogenetic therapy using the AAV2.7m8- ChR-tdT construct can partially restore vision in non-human primates to levels above those considered legally-blind. This study enables the identification of the most suitable construct for ongoing clinical trials attempting vision restoration in patients with retinitis pigmentosa.
Collapse
Affiliation(s)
- Gregory Gauvain
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France.
| | - Himanshu Akolkar
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France.,Department of Ophthalmology, University Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Antoine Chaffiol
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France
| | - Fabrice Arcizet
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France
| | - Mina A Khoei
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France
| | - Mélissa Desrosiers
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France
| | - Céline Jaillard
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France
| | - Romain Caplette
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France
| | - Olivier Marre
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France
| | - Stéphane Bertin
- CHNO des Quinze-Vingts, INSERM-DGOS CIC 1423, 28 rue de Charenton, F-75012, Paris, France
| | - Claire-Maelle Fovet
- Département des Sciences du Vivant (DSV), MIRcen, Institut d'imagerie Biomédicale (I2BM), Commissariat à l'Energie Atomique et aux Energies Alternatives (CEA), 92260, Fontenay-aux-Roses, France
| | - Joanna Demilly
- Département des Sciences du Vivant (DSV), MIRcen, Institut d'imagerie Biomédicale (I2BM), Commissariat à l'Energie Atomique et aux Energies Alternatives (CEA), 92260, Fontenay-aux-Roses, France
| | - Valérie Forster
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France
| | - Elena Brazhnikova
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France
| | - Philippe Hantraye
- Département des Sciences du Vivant (DSV), MIRcen, Institut d'imagerie Biomédicale (I2BM), Commissariat à l'Energie Atomique et aux Energies Alternatives (CEA), 92260, Fontenay-aux-Roses, France
| | - Pierre Pouget
- ICM, UMRS 1127 UPMC - U 1127 INSERM - UMR 7225 CNRS, Paris, France
| | - Anne Douar
- Gensight Biologics, 74 rue du faubourg Saint Antoine, F-75012, Paris, France
| | - Didier Pruneau
- Gensight Biologics, 74 rue du faubourg Saint Antoine, F-75012, Paris, France
| | - Joël Chavas
- Gensight Biologics, 74 rue du faubourg Saint Antoine, F-75012, Paris, France
| | - José-Alain Sahel
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France.,Department of Ophthalmology, University Pittsburgh Medical Center, Pittsburgh, PA, USA.,CHNO des Quinze-Vingts, INSERM-DGOS CIC 1423, 28 rue de Charenton, F-75012, Paris, France
| | - Deniz Dalkara
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France
| | - Jens Duebel
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France
| | - Ryad Benosman
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France.,Department of Ophthalmology, University Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Serge Picaud
- Sorbonne Université, INSERM, CNRS, Institut de la Vision, 17 rue Moreau, F-75012, Paris, France.
| |
Collapse
|
14
|
Park JH, Tan JSY, Wu H, Dong Y, Yoo J. 1225-Channel Neuromorphic Retinal-Prosthesis SoC With Localized Temperature-Regulation. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2020; 14:1230-1240. [PMID: 33156793 DOI: 10.1109/tbcas.2020.3036091] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A 1225-Channel Neuromorphic Retinal Prosthesis (RP) SoC is presented. Existing RP SoCs directly convert light intensity to electrical stimulus, which limit the adoption of delicate stimulus patterns to increase visual acuity. Moreover, a conventional centralized image processor leads to the local hot spot that poses a risk to the nearby retinal cells. To solve these issues, the proposed SoC adopts a distributed Neuromorphic Image Processor (NMIP) located within each pixel that extracts the outline of the incoming image, which reduces current dispersion and stimulus power compared with light-intensity proportional stimulus pattern. A spike-based asynchronous digital operation results in the power consumption of 56.3 nW/Ch without local temperature hot spot. At every 5×5 pixels, the localized (49-point) temperature-regulation circuit limits the temperature increase of neighboring retinal cells to less than 1 °C, and the overall power consumption of the SoC to be less than that of the human eye. The 1225-channel SoC fabricated in 0.18 μm 1P6M CMOS occupies 15mm2 while consuming 2.7 mW, and is successfully verified with image reconstruction demonstration.
Collapse
|
15
|
Song X, Guo T, Shivdasani MN, Dokos S, Lovell NH, Li X, Qiu S, Li T, Zheng S, Li L. Creation of virtual channels in the retina using synchronous and asynchronous stimulation - a modelling study. J Neural Eng 2020; 17. [PMID: 33086210 DOI: 10.1088/1741-2552/abc3a9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 10/21/2020] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Implantable retinal prostheses aim to provide artificial vision to those suffering from retinal degenerative diseases by electrically stimulating the remaining retinal neurons using a multi-electrode array. The spatial resolution of these devices can be improved by creation of so-called virtual channels (VCs) that are commonly achieved through synchronized stimulation of multiple electrodes. It is largely unclear though if VCs can be created using asynchronous stimulation, which was the primary aim of this study. APPROACH A computational model of multi-layered retina and epi-retinal dual-electrode stimulation was developed to simulate the neural activity of populations of retinal ganglion cells (RGCs) using the VC strategy under both synchronous and asynchronous stimulation conditions. MAIN RESULTS Our simulation suggests that VCs can be created using asynchronous stimulation. VC performance under both synchronous and asynchronous stimulation conditions can be improved by optimizing stimulation parameters such as current intensity, current ratio (α) between two electrodes, electrode spacing and the stimulation waveform. In particular, two VC performance measures; (1) linear displacement of the centroid of RGC activation, and (2) the RGC activation size consistency as a function of different current ratios α, have comparable performance under asynchronous and synchronous stimulation with appropriately selected stimulation parameters. SIGNIFICANCE Our findings support the possibility of creating VCs in the retina under both synchronous and asynchronous stimulation conditions. The results provide theoretical evidence for future retinal prosthesis designs with higher spatial resolution and power efficiency whilst reducing the number of current sources required to achieve these outcomes.
Collapse
Affiliation(s)
- Xiaoyu Song
- , Shanghai Jiao Tong University, Shanghai, 200240, CHINA
| | - Tianruo Guo
- GSBME, UNSW, Sydney, New South Wales, 2052, AUSTRALIA
| | - Mohit N Shivdasani
- Graduate School of Biomedical Engineering, University of New South Wales, Lower Ground, Samuels Building (F25), Kensington, New South Wales, AUSTRALIA
| | - Socrates Dokos
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney 2052, New South Wales, Sydney, New South Wales, 2052, AUSTRALIA
| | - Nigel H Lovell
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Sydney, 2052, AUSTRALIA
| | - Xinxin Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, CHINA
| | - Shirong Qiu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, CHINA
| | - Tong Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, CHINA
| | - Shiwei Zheng
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, CHINA
| | - Liming Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, Shanghai, CHINA
| |
Collapse
|
16
|
Ayton LN, Rizzo JF, Bailey IL, Colenbrander A, Dagnelie G, Geruschat DR, Hessburg PC, McCarthy CD, Petoe MA, Rubin GS, Troyk PR. Harmonization of Outcomes and Vision Endpoints in Vision Restoration Trials: Recommendations from the International HOVER Taskforce. Transl Vis Sci Technol 2020; 9:25. [PMID: 32864194 PMCID: PMC7426586 DOI: 10.1167/tvst.9.8.25] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Accepted: 12/08/2019] [Indexed: 01/05/2023] Open
Abstract
Translational research in vision prosthetics, gene therapy, optogenetics, stem cell and other forms of transplantation, and sensory substitution is creating new therapeutic options for patients with neural forms of blindness. The technical challenges faced by each of these disciplines differ considerably, but they all face the same challenge of how to assess vision in patients with ultra-low vision (ULV), who will be the earliest subjects to receive new therapies. Historically, there were few tests to assess vision in ULV patients. In the 1990s, the field of visual prosthetics expanded rapidly, and this activity led to a heightened need to develop better tests to quantify end points for clinical studies. Each group tended to develop novel tests, which made it difficult to compare outcomes across groups. The common lack of validation of the tests and the variable use of controls added to the challenge of interpreting the outcomes of these clinical studies. In 2014, at the bi-annual International “Eye and the Chip” meeting of experts in the field of visual prosthetics, a group of interested leaders agreed to work cooperatively to develop the International Harmonization of Outcomes and Vision Endpoints in Vision Restoration Trials (HOVER) Taskforce. Under this banner, more than 80 specialists across seven topic areas joined an effort to formulate guidelines for performing and reporting psychophysical tests in humans who participate in clinical trials for visual restoration. This document provides the complete version of the consensus opinions from the HOVER taskforce, which, together with its rules of governance, will be posted on the website of the Henry Ford Department of Ophthalmology (www.artificialvision.org). Research groups or companies that choose to follow these guidelines are encouraged to include a specific statement to that effect in their communications to the public. The Executive Committee of the HOVER Taskforce will maintain a list of all human psychophysical research in the relevant fields of research on the same website to provide an overview of methods and outcomes of all clinical work being performed in an attempt to restore vision to the blind. This website will also specify which scientific publications contain the statement of certification. The website will be updated every 2 years and continue to exist as a living document of worldwide efforts to restore vision to the blind. The HOVER consensus document has been written by over 80 of the world's experts in vision restoration and low vision and provides recommendations on the measurement and reporting of patient outcomes in vision restoration trials.
Collapse
Affiliation(s)
- Lauren N Ayton
- Department of Optometry and Vision Sciences and Department of Surgery (Ophthalmology), The University of Melbourne, Parkville, Australia.,Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia
| | - Joseph F Rizzo
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
| | - Ian L Bailey
- School of Optometry, University of California-Berkeley, Berkeley, CA, USA
| | - August Colenbrander
- Smith-Kettlewell Eye Research Institute and California Pacific Medical Center, San Francisco, CA, USA
| | - Gislin Dagnelie
- Lions Vision Research and Rehabilitation Center, Johns Hopkins Wilmer Eye Institute, Baltimore, MD, USA
| | - Duane R Geruschat
- Lions Vision Research and Rehabilitation Center, Johns Hopkins Wilmer Eye Institute, Baltimore, MD, USA
| | - Philip C Hessburg
- Detroit Institute of Ophthalmology, Henry Ford Health System, Grosse Pointe Park, MI, USA
| | - Chris D McCarthy
- Department of Computer Science & Software Engineering, Swinburne University of Technology, Melbourne, Australia
| | | | - Gary S Rubin
- University College London Institute of Ophthalmology, London, UK
| | - Philip R Troyk
- Armour College of Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | | |
Collapse
|
17
|
Shim S, Eom K, Jeong J, Kim SJ. Retinal Prosthetic Approaches to Enhance Visual Perception for Blind Patients. MICROMACHINES 2020; 11:E535. [PMID: 32456341 PMCID: PMC7281011 DOI: 10.3390/mi11050535] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 05/22/2020] [Accepted: 05/22/2020] [Indexed: 12/14/2022]
Abstract
Retinal prostheses are implantable devices that aim to restore the vision of blind patients suffering from retinal degeneration, mainly by artificially stimulating the remaining retinal neurons. Some retinal prostheses have successfully reached the stage of clinical trials; however, these devices can only restore vision partially and remain insufficient to enable patients to conduct everyday life independently. The visual acuity of the artificial vision is limited by various factors from both engineering and physiological perspectives. To overcome those issues and further enhance the visual resolution of retinal prostheses, a variety of retinal prosthetic approaches have been proposed, based on optimization of the geometries of electrode arrays and stimulation pulse parameters. Other retinal stimulation modalities such as optics, ultrasound, and magnetics have also been utilized to address the limitations in conventional electrical stimulation. Although none of these approaches have been clinically proven to fully restore the function of a degenerated retina, the extensive efforts made in this field have demonstrated a series of encouraging findings for the next generation of retinal prostheses, and these could potentially enhance the visual acuity of retinal prostheses. In this article, a comprehensive and up-to-date overview of retinal prosthetic strategies is provided, with a specific focus on a quantitative assessment of visual acuity results from various retinal stimulation technologies. The aim is to highlight future directions toward high-resolution retinal prostheses.
Collapse
Affiliation(s)
- Shinyong Shim
- Department of Electrical and Computer Engineering, College of Engineering, Seoul National University, Seoul 08826, Korea;
- Inter-university Semiconductor Research Center, College of Engineering, Seoul National University, Seoul 08826, Korea
| | - Kyungsik Eom
- Department of Electronics Engineering, College of Engineering, Pusan National University, Busan 46241, Korea
| | - Joonsoo Jeong
- School of Biomedical Convergence Engineering, College of Information and Biomedical Engineering, Pusan National University, Yangsan 50612, Korea
| | - Sung June Kim
- Department of Electrical and Computer Engineering, College of Engineering, Seoul National University, Seoul 08826, Korea;
- Inter-university Semiconductor Research Center, College of Engineering, Seoul National University, Seoul 08826, Korea
- Institute on Aging, College of Medicine, Seoul National University, Seoul 08826, Korea
| |
Collapse
|
18
|
Chen J, Poulaki V, Kim SJ, Eldred WD, Kane S, Gingerich M, Shire DB, Jensen R, DeWalt G, Kaplan HJ, Rizzo JF. Implantation and Extraction of Penetrating Electrode Arrays in Minipig Retinas. Transl Vis Sci Technol 2020; 9:19. [PMID: 32821491 PMCID: PMC7401973 DOI: 10.1167/tvst.9.5.19] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Accepted: 12/31/2019] [Indexed: 12/12/2022] Open
Abstract
Purpose This work was motivated by the goals of demonstrating methods to fabricate and implant large numbers of penetrating arrays into the retina and the feasibility of extraction. Methods Arrays of inactive, three-dimensional (3D) SU-8 structures were microfabricated onto 13-µm polyimide substrates. Standard vitreoretinal surgical techniques were used with an ab externo approach for subretinal implantation of arrays in 12 mini-pigs. In the first three surgeries, different post-geometries were explored, while a preferred design (128-µm tall, 30-µm diameter, 200-µm spacing) was used for the remaining nine implantations. Two arrays were extracted. Funduscopy, optical coherence tomography (OCT) and immunohistochemistry of the retinae were performed. The unoperated eyes and tissue far from implantation served as controls. A thirteenth pig was implanted with a planar array. Results Ten implant surgeries had no significant complication, and two arrays were successfully extracted. One retinal tear occurred after implantation due to too long posts in an early surgery. In “successful” cases, OCT showed close apposition of the arrays to the retina and integration of the posts, the tops of which were positioned at the junction of the inner plexiform and ganglion cells, without significant gliosis. Conclusions These results provide a proof-of-concept that relatively large numbers of 3D posts can be implanted into, and extracted from, the retina of mini-pigs. Our surgical numbers were relatively small, especially for the extractions, and our conclusions must be viewed with that limitation. Our methods are applicable for human surgeries. Translational Relevance This study provides results of implantation and extraction of relatively large numbers of 3D posts from the retina of minipig eyes. If similar technology were used in humans, a 3D array of this type should lower perceptual thresholds, provide safer long-term stimulation, and perhaps provide better perceptual outcomes.
Collapse
Affiliation(s)
- Jinghua Chen
- Department of Ophthalmology, University of Florida, College of Medicine, Gainesville, FL, USA
| | - Vasiliki Poulaki
- Boston VA Healthcare System, Ophthalmology, Jamaica Plain, Boston, MA, USA
| | - Seong-Joon Kim
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| | | | | | | | | | - Ralph Jensen
- Boston VA Healthcare System, Ophthalmology, Jamaica Plain, Boston, MA, USA
| | - Gloria DeWalt
- Department of Biology, Boston University, Boston, MA, USA
| | - Henry J Kaplan
- Department of Ophthalmology and Visual Sciences, University of Louisville, Louisville, KY, USA
| | - Joseph F Rizzo
- Department of Ophthalmology, Harvard Medical School and the Massachusetts Eye and Ear, Boston, MA, USA
| |
Collapse
|
19
|
Spatiotemporal integration of visual stimuli and its relevance to the use of a divisional power supply scheme for retinal prosthesis. PLoS One 2020; 15:e0228861. [PMID: 32084146 PMCID: PMC7034871 DOI: 10.1371/journal.pone.0228861] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2019] [Accepted: 01/25/2020] [Indexed: 11/19/2022] Open
Abstract
A wireless photovoltaic retinal prosthesis is currently being studied with the aim of providing prosthetic vision to patients with retinitis pigmentosa (RP) and age-related macular degeneration (AMD). The major challenge of a photovoltaic device is its limited power efficiency. Our retinal prosthetic design implements a unique divisional power supply scheme (DPSS) system that provides the electrical power generated by all of the solar cells to only a subset of electrodes at any moment in time. The aim of the present study was to systematically characterize the spatiotemporal integration performance of the system under various DPSS conditions using human subjects and a psychophysical approach. A 16x16 pixels LED array controlled by Arduino was used to simulate the output signal of the DPSS design, and human performance under different visual stimulations at various update frequencies was then used to assess the spatiotemporal capability of retinal prostheses. The results showed that the contrast polarity of the image, image brightness, and division number influenced the lower limit of the update frequency of the DPSS system, while, on the other hand, visual angle, ambient light level, and stimulation order did not affect performance significantly. Pattern recognition by visual persistence with spatiotemporal integration of multiple frames of sparse dots is a feasible approach in retinal prosthesis design. These findings provide an insight into how to optimize a photovoltaic retinal prosthesis using a DPSS design with an appropriate update frequency for reliable pattern recognition. This will help the development of a wireless device able to restore vision to RP and AMD patients in the future.
Collapse
|
20
|
An update on retinal prostheses. Clin Neurophysiol 2019; 131:1383-1398. [PMID: 31866339 DOI: 10.1016/j.clinph.2019.11.029] [Citation(s) in RCA: 84] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 11/13/2019] [Accepted: 11/14/2019] [Indexed: 11/23/2022]
Abstract
Retinal prostheses are designed to restore a basic sense of sight to people with profound vision loss. They require a relatively intact posterior visual pathway (optic nerve, lateral geniculate nucleus and visual cortex). Retinal implants are options for people with severe stages of retinal degenerative disease such as retinitis pigmentosa and age-related macular degeneration. There have now been three regulatory-approved retinal prostheses. Over five hundred patients have been implanted globally over the past 15 years. Devices generally provide an improved ability to localize high-contrast objects, navigate, and perform basic orientation tasks. Adverse events have included conjunctival erosion, retinal detachment, loss of light perception, and the need for revision surgery, but are rare. There are also specific device risks, including overstimulation (which could cause damage to the retina) or delamination of implanted components, but these are very unlikely. Current challenges include how to improve visual acuity, enlarge the field-of-view, and reduce a complex visual scene to its most salient components through image processing. This review encompasses the work of over 40 individual research groups who have built devices, developed stimulation strategies, or investigated the basic physiology underpinning retinal prostheses. Current technologies are summarized, along with future challenges that face the field.
Collapse
|
21
|
A model of ganglion axon pathways accounts for percepts elicited by retinal implants. Sci Rep 2019; 9:9199. [PMID: 31235711 PMCID: PMC6591412 DOI: 10.1038/s41598-019-45416-4] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Accepted: 06/04/2019] [Indexed: 11/09/2022] Open
Abstract
Degenerative retinal diseases such as retinitis pigmentosa and macular degeneration cause irreversible vision loss in more than 10 million people worldwide. Retinal prostheses, now implanted in over 250 patients worldwide, electrically stimulate surviving cells in order to evoke neuronal responses that are interpreted by the brain as visual percepts ('phosphenes'). However, instead of seeing focal spots of light, current implant users perceive highly distorted phosphenes that vary in shape both across subjects and electrodes. We characterized these distortions by asking users of the Argus retinal prosthesis system (Second Sight Medical Products Inc.) to draw electrically elicited percepts on a touchscreen. Using ophthalmic fundus imaging and computational modeling, we show that elicited percepts can be accurately predicted by the topographic organization of optic nerve fiber bundles in each subject's retina, successfully replicating visual percepts ranging from 'blobs' to oriented 'streaks' and 'wedges' depending on the retinal location of the stimulating electrode. This provides the first evidence that activation of passing axon fibers accounts for the rich repertoire of phosphene shape commonly reported in psychophysical experiments, which can severely distort the quality of the generated visual experience. Overall our findings argue for more detailed modeling of biological detail across neural engineering applications.
Collapse
|
22
|
Zeng Q, Zhao S, Yang H, Zhang Y, Wu T. Micro/Nano Technologies for High-Density Retinal Implant. MICROMACHINES 2019; 10:E419. [PMID: 31234507 PMCID: PMC6630275 DOI: 10.3390/mi10060419] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Revised: 06/14/2019] [Accepted: 06/21/2019] [Indexed: 01/10/2023]
Abstract
During the past decades, there have been leaps in the development of micro/nano retinal implant technologies, which is one of the emerging applications in neural interfaces to restore vision. However, higher feedthroughs within a limited space are needed for more complex electronic systems and precise neural modulations. Active implantable medical electronics are required to have good electrical and mechanical properties, such as being small, light, and biocompatible, and with low power consumption and minimal immunological reactions during long-term implantation. For this purpose, high-density implantable packaging and flexible microelectrode arrays (fMEAs) as well as high-performance coating materials for retinal stimulation are crucial to achieve high resolution. In this review, we mainly focus on the considerations of the high-feedthrough encapsulation of implantable biomedical components to prolong working life, and fMEAs for different implant sites to deliver electrical stimulation to targeted retinal neuron cells. In addition, the functional electrode materials to achieve superior stimulation efficiency are also reviewed. The existing challenge and future research directions of micro/nano technologies for retinal implant are briefly discussed at the end of the review.
Collapse
Affiliation(s)
- Qi Zeng
- Shenzhen Institutes of Advanced Technology (SIAT), Chinese Academy of Sciences (CAS), Shenzhen 518055, China.
| | - Saisai Zhao
- Shenzhen Institutes of Advanced Technology (SIAT), Chinese Academy of Sciences (CAS), Shenzhen 518055, China.
| | - Hangao Yang
- Shenzhen Institutes of Advanced Technology (SIAT), Chinese Academy of Sciences (CAS), Shenzhen 518055, China.
| | - Yi Zhang
- Shenzhen CAS-Envision Medical Technology Co. Ltd., Shenzhen 518100, China.
| | - Tianzhun Wu
- Shenzhen Institutes of Advanced Technology (SIAT), Chinese Academy of Sciences (CAS), Shenzhen 518055, China.
| |
Collapse
|
23
|
Manfredi G, Colombo E, Barsotti J, Benfenati F, Lanzani G. Photochemistry of Organic Retinal Prostheses. Annu Rev Phys Chem 2019; 70:99-121. [DOI: 10.1146/annurev-physchem-042018-052445] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Organic devices are attracting considerable attention as prostheses for the recovery of retinal light sensitivity lost to retinal degenerative disease. The biotic/abiotic interface created when light-sensitive polymers and living tissues are placed in contact allows excitation of a response in blind laboratory rats exposed to visual stimuli. Although polymer retinal prostheses have proved to be efficient, their working mechanism is far from being fully understood. In this review article, we discuss the results of the studies conducted on these kinds of polymer devices and compare them with the data found in the literature for inorganic retinal prostheses, where the working mechanisms are better comprehended. This comparison, which tries to set some reference values and figures of merit, is intended for use as a starting point to determine the direction for further investigation.
Collapse
Affiliation(s)
- Giovanni Manfredi
- Center for Nano Science and Technology, Istituto Italiano di Tecnologia, 20133 Milan, Italy;,
| | - Elisabetta Colombo
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, 16132 Genoa, Italy;,
| | - Jonathan Barsotti
- Center for Nano Science and Technology, Istituto Italiano di Tecnologia, 20133 Milan, Italy;,
| | - Fabio Benfenati
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, 16132 Genoa, Italy;,
- Department of Experimental Medicine, University of Genoa, 16132 Genoa, Italy
| | - Guglielmo Lanzani
- Center for Nano Science and Technology, Istituto Italiano di Tecnologia, 20133 Milan, Italy;,
- Department of Physics, Politecnico di Milano, 20133 Milan, Italy
| |
Collapse
|
24
|
Wang L, Sharifian F, Napp J, Nath C, Pollmann S. Cross-task perceptual learning of object recognition in simulated retinal implant perception. J Vis 2018; 18:22. [PMID: 30593067 DOI: 10.1167/18.13.22] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
The perception gained by retina implants (RI) is limited, which asks for a learning regime to improve patients' visual perception. Here we simulated RI vision and investigated if object recognition in RI patients can be improved and maintained through training. Importantly, we asked if the trained object recognition can be generalized to a new task context, and to new viewpoints of the trained objects. For this purpose, we adopted two training tasks, a labelling task where participants had to choose the correct label out of other distracting labels for the presented object, and a reverse labelling task where participants had to choose the correct object out of other distracting objects to match the presented label. Our results showed that, despite of the task order, recognition performance was improved in both tasks and lasted at least for a week. The improved object recognition, however, can be transferred only from the labelling task to the reverse labelling task but not vice versa. Additionally, the trained object recognition can be transferred to new viewpoints of the trained objects only in the labelling task but not in the reverse labelling task. Training with the labelling task is therefore recommended for RI patients to achieve persistent and flexible visual perception.
Collapse
Affiliation(s)
- Lihui Wang
- Department of Psychology, Otto-von-Guericke University Magdeburg, Germany.,Center for Behavioral Brain Sciences, Otto-von-Guericke University Magdeburg, Germany
| | - Fariba Sharifian
- Department of Psychology, Otto-von-Guericke University Magdeburg, Germany.,Department of Cognitive Psychology, Institute of Cognitive Neuroscience, Faculty of Psychology, Ruhr University Bochum, Germany
| | - Jonathan Napp
- Department of Psychology, Otto-von-Guericke University Magdeburg, Germany
| | - Carola Nath
- Department of Psychology, Otto-von-Guericke University Magdeburg, Germany
| | - Stefan Pollmann
- Department of Psychology, Otto-von-Guericke University Magdeburg, Germany.,Center for Behavioral Brain Sciences, Otto-von-Guericke University Magdeburg, Germany
| |
Collapse
|
25
|
Bareket L, Barriga-Rivera A, Zapf MP, Lovell NH, Suaning GJ. Progress in artificial vision through suprachoroidal retinal implants. J Neural Eng 2018; 14:045002. [PMID: 28541930 DOI: 10.1088/1741-2552/aa6cbb] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Retinal implants have proven their ability to restore visual sensation to people with degenerative retinopathy, characterized by photoreceptor cell death and the retina's inability to sense light. Retinal bionics operate by electrically stimulating the surviving neurons in the retina, thus triggering the transfer of visual sensory information to the brain. Suprachoroidal implants were first investigated in Australia in the 1950s. In this approach, the neuromodulation hardware is positioned between the sclera and the choroid, thus providing significant surgical and safety benefits for patients, with the potential to maintain residual vision combined with the artificial input from the device. Here we review the latest advances and state of the art devices for suprachoroidal prostheses, highlight future technologies and discuss challenges and perspectives towards improved rehabilitation of vision.
Collapse
Affiliation(s)
- Lilach Bareket
- Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia
| | | | | | | | | |
Collapse
|
26
|
Yang CY, Tsai D, Guo T, Dokos S, Suaning GJ, Morley JW, Lovell NH. Differential electrical responses in retinal ganglion cell subtypes: effects of synaptic blockade and stimulating electrode location. J Neural Eng 2018; 15:046020. [PMID: 29737971 DOI: 10.1088/1741-2552/aac315] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Visual prostheses have shown promising results in restoring visual perception to blind patients. The ability to differentially activate retinal ganglion cell (RGC) subtypes could further improve the efficacy of these medical devices. APPROACH Using whole-cell patch clamp, we investigated membrane potential differences between ON and OFF RGCs in the mouse retina when their synaptic inputs were blocked by synaptic blockers, and examined the differences in stimulation thresholds under such conditions. By injecting intracellular current, we further confirmed the relationship between RGC stimulation thresholds and resting membrane potentials (RMPs). In addition, we investigated the effects of stimulating electrode location on the differences in stimulation thresholds between ON and OFF RGCs. MAIN RESULTS With synaptic blockade, ON RGCs became significantly more hyperpolarized (from -61.8 ± 1.4 mV to -70.8 ± 1.6 mV), while OFF RGCs depolarized slightly (from -60.5 ± 0.7 mV to -58.6 ± 0.9 mV). RGC stimulation thresholds were negatively correlated with their RMPs (Pearson r value: -0.5154; p-value: 0.0042). Thus, depriving ON RGCs of synaptic inputs significantly increased their thresholds (from 14.7 ± 1.3 µA to 22.3 ± 2.1 µA) over those of OFF RGCs (from 13.2 ± 0.7 µA to 13.1 ± 1.1 µA). However, with control solution, ON and OFF RGC stimulation thresholds were not significantly different. Finally, placement of the stimulating electrode away from the axon enhanced differences in stimulation thresholds between ON and OFF RGCs, facilitating preferential activation of OFF RGCs. SIGNIFICANCE Since ON and OFF RGCs have antagonistic responses to natural light, achieving differential RGC activation could convey more natural visual information, leading to better visual prosthesis outcomes.
Collapse
Affiliation(s)
- Chih Yu Yang
- Graduate School of Biomedical Engineering, UNSW, Sydney, NSW 2052, Australia
| | | | | | | | | | | | | |
Collapse
|
27
|
Watterson WJ, Montgomery RD, Taylor RP. Modeling the Improved Visual Acuity Using Photodiode Based Retinal Implants Featuring Fractal Electrodes. Front Neurosci 2018; 12:277. [PMID: 29740278 PMCID: PMC5928399 DOI: 10.3389/fnins.2018.00277] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Accepted: 04/10/2018] [Indexed: 11/23/2022] Open
Abstract
Electronically restoring vision to patients blinded by severe retinal degenerations is rapidly becoming a realizable feat through retinal implants. Upon receiving an implant, previously blind patients can now detect light, locate objects, and determine object motion direction. However, the restored visual acuity (VA) is still significantly below the legal blindness level (VA < 20/200). The goal of this research is to optimize the inner electrode geometry in photovoltaic subretinal implants in order to restore vision to a VA better than blindness level. We simulated neural stimulation by 20 μm subretinal photovoltaic implants featuring square or fractal inner electrodes by: (1) calculating the voltage generated on the inner electrode based on the amount of light entering the photodiode, (2) mapping how this voltage spreads throughout the extracellular space surrounding retinal bipolar neurons, and (3) determining if these extracellular voltages are sufficient for neural stimulation. By optimizing the fractal inner electrode geometry, we show that all neighboring neurons can be stimulated using an irradiance of 12 mW/mm2, while the optimized square only stimulates ~10% of these neurons at an equivalent irradiance. The 20 μm fractal electrode can thus theoretically restore VA up to 20/80, if other limiting factors common to retinal degenerations, such as glia scarring and rewiring of retinal circuits, could be reduced. For the optimized square to stimulate all neighboring neurons, the irradiance has to be increased by almost 300%, which is very near the maximum permissible exposure safety limit. This demonstration that fractal electrodes can stimulate targeted neurons for long periods using safe irradiance levels highlights the possibility for restoring vision to a VA better than the blindness level using photodiode-based retinal implants.
Collapse
Affiliation(s)
| | | | - Richard P Taylor
- Physics Department, University of Oregon, Eugene, OR, United States
| |
Collapse
|
28
|
Implantation, removal and replacement of subretinal electronic implants for restoration of vision in patients with retinitis pigmentosa. Curr Opin Ophthalmol 2018. [PMID: 29528862 DOI: 10.1097/icu.0000000000000467] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE OF REVIEW The purpose of this review is to provide an update on the efforts to restore vision through subretinal implants in patients with degenerative retinal diseases. In addition to the current technique and its latest improvements, it will focus on the surgical technique of implantation as well as explantation and reimplantation. RECENT FINDINGS The durability of the current subretinal implant RETINA IMPLANT Alpha AMS has increased substantially compared with the predecessor model RETINA IMPLANT Alpha IMS. According to validated examinations in the laboratory, a median lifetime of 4.7 years will be reached in clinical use; in similar examinations, the previous model has reached only 8 months. Visual function has slightly increased. The surgical technique for subretinal implants is complex and demanding for ophthalmic surgeons, as it is multifaceted and combines novel surgical steps in areas, which are not commonly entered such as the suprachoroidal and the subretinal space. The surgical approach for implantation has matured considerably and has led to successful implantation in 64 patient cases. Surgical challenges are now mainly encountered with the exact subfoveal positioning of the device. The explantation procedure is relatively straight-forward because the implant can be withdrawn in a reverse direction along the already existent subretinal path. Reimplantations, however, are more challenging because some degree of scar tissue may exist along the path of the chip and around the scleral trapdoor. Nevertheless, reimplantations have now been carried out successfully in four patients. SUMMARY The new RETINA IMPLANT Alpha AMS shows significantly improved durability compared with the predecessor model RETINA IMPLANT Alpha IMS. The subretinal implant offers excellent visual results but requires experienced surgeons. Explantation of devices is straight-forward, and reimplantations are challenging but have been successful in four patients.
Collapse
|
29
|
Spencer TC, Fallon JB, Shivdasani MN. Creating virtual electrodes with 2D current steering. J Neural Eng 2018; 15:035002. [DOI: 10.1088/1741-2552/aab1b8] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
30
|
Im M, Werginz P, Fried SI. Electric stimulus duration alters network-mediated responses depending on retinal ganglion cell type. J Neural Eng 2018; 15:036010. [PMID: 29415876 DOI: 10.1088/1741-2552/aaadc1] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
OBJECTIVE To improve the quality of artificial vision that arises from retinal prostheses, it is important to bring electrically-elicited neural activity more in line with the physiological signaling patterns that arise normally in the healthy retina. Our previous study reported that indirect activation produces a closer match to physiological responses in ON retinal ganglion cells (RGCs) than in OFF cells (Im and Fried 2015 J. Physiol. 593 3677-96). This suggests that a preferential activation of ON RGCs would shape the overall retinal response closer to natural signaling. Recently, we found that changes to the rate at which stimulation was delivered could bias responses towards a stronger ON component (Im and Fried 2016a J. Neural Eng. 13 025002), raising the possibility that changes to other stimulus parameters can similarly bias towards stronger ON responses. Here, we explore the effects of changing stimulus duration on the responses in ON and OFF types of brisk transient (BT) and brisk sustained (BS) RGCs. APPROACH We used cell-attached patch clamp to record RGC spiking in the isolated rabbit retina. Targeted RGCs were first classified as ON or OFF type by their light responses, and further sub-classified as BT or BS types by their responses to both light and electric stimuli. Spiking in targeted RGCs was recorded in response to electric pulses with durations varying from 5 to100 ms. Stimulus amplitude was adjusted at each duration to hold total charge constant for all experiments. MAIN RESULTS We found that varying stimulus durations modulated responses differentially for ON versus OFF cells: in ON cells, spike counts decreased significantly with increasing stimulus duration while in OFF cells the changes were more modest. The maximum ratio of ON versus OFF responses occurred at a duration of ~10 ms. The difference in response strength for BT versus BS cells was much larger in ON cells than in OFF cells. SIGNIFICANCE The stimulation rates preferred by subjects during clinical trials are similar to the rates that maximize the ON/OFF response ratio in in vitro testing (Im and Fried 2016a J. Neural Eng. 13 025002). Here, we determine the stimulus duration that produces the strongest bias towards ON responses and speculate that it will further enhance clinical effectiveness.
Collapse
Affiliation(s)
- Maesoon Im
- Department of Ophthalmology, Henry Ford Health System, 1 Ford Place, Detroit, MI 48202, United States of America. Department of Anatomy and Cell Biology, Wayne State University School of Medicine, 540 East Canfield Street, Detroit, MI 48201, United States of America. Department of Electrical and Computer Engineering, Wayne State University College of Engineering, 5050 Anthony Wayne Drive, Detroit, MI 48202, United States of America. Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, 50 Blossom Street, Boston, MA 02114, United States of America
| | | | | |
Collapse
|
31
|
Chen Y, Fu J, Chu D, Li R, Xie Y. An image-processing strategy to extract important information suitable for a low-size stimulus pattern in a retinal prosthesis. BIOMED ENG-BIOMED TE 2017; 62:591-598. [PMID: 28258971 DOI: 10.1515/bmt-2016-0049] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2016] [Accepted: 11/01/2016] [Indexed: 11/15/2022]
Abstract
BACKGROUND A retinal prosthesis is designed to help the blind to obtain some sight. It consists of an external part and an internal part. The external part is made up of a camera, an image processor and an RF transmitter. The internal part is made up of an RF receiver, implant chip and microelectrode. METHODS Currently, the number of microelectrodes is in the hundreds, and we do not know the mechanism for using an electrode to stimulate the optic nerve. A simple hypothesis is that the pixels in an image correspond to the electrode. The images captured by the camera should be processed by suitable strategies to correspond to stimulation from the electrode. Thus, it is a question of how to obtain the important information from the image captured in the picture. Here, we use the region of interest (ROI), a useful algorithm for extracting the ROI, to retain the important information, and to remove the redundant information. RESULTS This paper explains the details of the principles and functions of the ROI. Because we are investigating a real-time system, we need a fast processing ROI as a useful algorithm to extract the ROI. Thus, we simplified the ROI algorithm and used it in an outside image-processing digital signal processing (DSP) system of the retinal prosthesis. CONCLUSION The results show that our image-processing strategies are suitable for a real-time retinal prosthesis and can eliminate redundant information and provide useful information for expression in a low-size image.
Collapse
|
32
|
Nuzzi R, Tridico F. Glaucoma: Biological Trabecular and Neuroretinal Pathology with Perspectives of Therapy Innovation and Preventive Diagnosis. Front Neurosci 2017; 11:494. [PMID: 28928631 PMCID: PMC5591842 DOI: 10.3389/fnins.2017.00494] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2017] [Accepted: 08/22/2017] [Indexed: 12/14/2022] Open
Abstract
Glaucoma is a common degenerative disease affecting retinal ganglion cells (RGC) and optic nerve axons, with progressive and chronic course. It is one of the most important reasons of social blindness in industrialized countries. Glaucoma can lead to the development of irreversible visual field loss, if not treated. Diagnosis may be difficult due to lack of symptoms in early stages of disease. In many cases, when patients arrive at clinical evaluation, a severe neuronal damage may have already occurred. In recent years, newer perspective in glaucoma treatment have emerged. The current research is focusing on finding newer drugs and associations or better delivery systems in order to improve the pharmacological treatment and patient compliance. Moreover, the application of various stem cell types with restorative and neuroprotective intent may be found appealing (intravitreal autologous cellular therapy). Advances are made also in terms of parasurgical treatment, characterized by various laser types and techniques. Moreover, recent research has led to the development of central and peripheral retinal rehabilitation (featuring residing cells reactivation and replacement of defective elements), as well as innovations in diagnosis through more specific and refined methods and inexpensive tests.
Collapse
Affiliation(s)
- Raffaele Nuzzi
- Eye Clinic Section, Department of Surgical Sciences, University of Turin, Ophthalmic HospitalTurin, Italy
| | - Federico Tridico
- Eye Clinic Section, Department of Surgical Sciences, University of Turin, Ophthalmic HospitalTurin, Italy
| |
Collapse
|
33
|
Irons JL, Gradden T, Zhang A, He X, Barnes N, Scott AF, McKone E. Face identity recognition in simulated prosthetic vision is poorer than previously reported and can be improved by caricaturing. Vision Res 2017; 137:61-79. [PMID: 28688907 DOI: 10.1016/j.visres.2017.06.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2017] [Revised: 04/15/2017] [Accepted: 06/08/2017] [Indexed: 10/19/2022]
Abstract
The visual prosthesis (or "bionic eye") has become a reality but provides a low resolution view of the world. Simulating prosthetic vision in normal-vision observers, previous studies report good face recognition ability using tasks that allow recognition to be achieved on the basis of information that survives low resolution well, including basic category (sex, age) and extra-face information (hairstyle, glasses). Here, we test within-category individuation for face-only information (e.g., distinguishing between multiple Caucasian young men with hair covered). Under these conditions, recognition was poor (although above chance) even for a simulated 40×40 array with all phosphene elements assumed functional, a resolution above the upper end of current-generation prosthetic implants. This indicates that a significant challenge is to develop methods to improve face identity recognition. Inspired by "bionic ear" improvements achieved by altering signal input to match high-level perceptual (speech) requirements, we test a high-level perceptual enhancement of face images, namely face caricaturing (exaggerating identity information away from an average face). Results show caricaturing improved identity recognition in memory and/or perception (degree by which two faces look dissimilar) down to a resolution of 32×32 with 30% phosphene dropout. Findings imply caricaturing may offer benefits for patients at resolutions realistic for some current-generation or in-development implants.
Collapse
Affiliation(s)
- Jessica L Irons
- Research School of Psychology, Australian National University, Australia; ARC Centre for Cognition and Its Disorders, Australian National University, Australia.
| | - Tamara Gradden
- Research School of Psychology, Australian National University, Australia
| | - Angel Zhang
- Research School of Psychology, Australian National University, Australia
| | - Xuming He
- National Information and Communication Technology Australia (NICTA), Australia; College of Engineering and Computer Science, Australian National University, Australia; Data61, CSIRO, Australia
| | - Nick Barnes
- National Information and Communication Technology Australia (NICTA), Australia; College of Engineering and Computer Science, Australian National University, Australia; Bionic Vision Australia, Australia; Data61, CSIRO, Australia
| | - Adele F Scott
- National Information and Communication Technology Australia (NICTA), Australia; Bionic Vision Australia, Australia; Data61, CSIRO, Australia
| | - Elinor McKone
- Research School of Psychology, Australian National University, Australia; ARC Centre for Cognition and Its Disorders, Australian National University, Australia.
| |
Collapse
|
34
|
Mills JO, Jalil A, Stanga PE. Electronic retinal implants and artificial vision: journey and present. Eye (Lond) 2017; 31:1383-1398. [PMID: 28548648 DOI: 10.1038/eye.2017.65] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2016] [Accepted: 01/20/2017] [Indexed: 02/07/2023] Open
Abstract
Retinitis pigmentosa and age-related macular degeneration are two significant causes of severe visual dysfunction. In both, the retinal photoreceptors degenerate, preventing successful conversion of light into electrical energy that is interpreted in the visual cortex as visual function. Artificial vision or visual function began over two centuries ago with the idea of creating artificial light pulses, or phosphenes, through cortical stimulation. The pursuit is now on to improve artificial visual function. Two retinal implants appear the most likely to succeed in the future having undergone multicentre human trials: the Argus II electronic epiretinal device (Second Sight Medical Products, CA, USA) and Alpha-IMS electronic subretinal device (Retina Implant AG, Germany). The trial results to date are encouraging with visual improvement and acceptable safety profiles reported for both devices. At present, the visual function generated by either device does not offer high enough resolution or acuity for a patient to regain a fully functional life. Despite this, both devices not only have the potential, but have actually improved the vision-related quality of life in a significant number of patients implanted. With this in mind, the economic argument is clear. Provided device-life is long enough, its cost should be acceptable for the obtained improvement in the quality of life. The aim of this Review Article is to assist those readers that may be considering offering any of these devices as a treatment for blindness in Retinitis Pigmentosa.
Collapse
Affiliation(s)
- J O Mills
- Manchester Royal Eye Hospital, Manchester, UK.,Manchester Vision Regeneration (MVR) Lab at Manchester Royal Eye Hospital, NIHR/ Wellcome Trust Manchester CRF, Manchester Royal Eye Hospital, Manchester, UK
| | - A Jalil
- Manchester Royal Eye Hospital, Manchester, UK.,Manchester Vision Regeneration (MVR) Lab at Manchester Royal Eye Hospital, NIHR/ Wellcome Trust Manchester CRF, Manchester Royal Eye Hospital, Manchester, UK
| | - P E Stanga
- Manchester Royal Eye Hospital, Manchester, UK.,Manchester Vision Regeneration (MVR) Lab at Manchester Royal Eye Hospital, NIHR/ Wellcome Trust Manchester CRF, Manchester Royal Eye Hospital, Manchester, UK.,Manchester Academic Health Science Centre and Centre for Ophthalmology and Vision Research, Institute of Human Development, University of Manchester, Manchester, UK
| |
Collapse
|
35
|
Barriga-Rivera A, Guo T, Yang CY, Abed AA, Dokos S, Lovell NH, Morley JW, Suaning GJ. High-amplitude electrical stimulation can reduce elicited neuronal activity in visual prosthesis. Sci Rep 2017; 7:42682. [PMID: 28209965 PMCID: PMC5314337 DOI: 10.1038/srep42682] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Accepted: 01/13/2017] [Indexed: 12/13/2022] Open
Abstract
Retinal electrostimulation is promising a successful therapy to restore functional vision. However, a narrow stimulating current range exists between retinal neuron excitation and inhibition which may lead to misperformance of visual prostheses. As the conveyance of representation of complex visual scenes may require neighbouring electrodes to be activated simultaneously, electric field summation may contribute to reach this inhibitory threshold. This study used three approaches to assess the implications of relatively high stimulating conditions in visual prostheses: (1) in vivo, using a suprachoroidal prosthesis implanted in a feline model, (2) in vitro through electrostimulation of murine retinal preparations, and (3) in silico by computing the response of a population of retinal ganglion cells. Inhibitory stimulating conditions led to diminished cortical activity in the cat. Stimulus-response relationships showed non-monotonic profiles to increasing stimulating current. This was observed in vitro and in silico as the combined response of groups of neurons (close to the stimulating electrode) being inhibited at certain stimulating amplitudes, whilst other groups (far from the stimulating electrode) being recruited. These findings may explain the halo-like phosphene shapes reported in clinical trials and suggest that simultaneous stimulation in retinal prostheses is limited by the inhibitory threshold of the retinal ganglion cells.
Collapse
Affiliation(s)
| | - Tianruo Guo
- Graduate School of Biomedical Engineering, UNSW, Sydney, 2052, Australia
| | - Chih-Yu Yang
- Graduate School of Biomedical Engineering, UNSW, Sydney, 2052, Australia
| | - Amr Al Abed
- Graduate School of Biomedical Engineering, UNSW, Sydney, 2052, Australia
| | - Socrates Dokos
- Graduate School of Biomedical Engineering, UNSW, Sydney, 2052, Australia
| | - Nigel H Lovell
- Graduate School of Biomedical Engineering, UNSW, Sydney, 2052, Australia
| | - John W Morley
- School of Medicine, Western Sydney University, Sydney, 2753, Australia.,School of Medical Science, UNSW, Sydney, 2052, Australia
| | - Gregg J Suaning
- Graduate School of Biomedical Engineering, UNSW, Sydney, 2052, Australia.,Sydney Medical School, University of Sydney, 2000, Australia
| |
Collapse
|
36
|
Abstract
Choroid supplies the major blood supply to the eye, especially the outer retinal structures. Its understanding has significantly improved with the advent of advanced imaging modalities such as enhanced depth imaging technique and the newer swept source optical coherence tomography. Recent literature reports the findings of choroidal changes, quantitative as well as qualitative, in various chorioretinal disorders. This review article describes applications of choroidal imaging in the management of common diseases such as age-related macular degeneration, high myopia, central serous chorioretinopathy, chorioretinal inflammatory diseases, and tumors. This article briefly discusses future directions in choroidal imaging including angiography.
Collapse
Affiliation(s)
- Jay Chhablani
- Smt. Kanuri Santhamma Retina Vitreous Centre, L. V. Prasad Eye Institute, Hyderabad, Telangana, India
| | | |
Collapse
|
37
|
Jung SW, Shin JY, Pi K, Goo YS, Cho DID. Neuron Stimulation Device Integrated with Silicon Nanowire-Based Photodetection Circuit on a Flexible Substrate. SENSORS 2016; 16:s16122035. [PMID: 27916963 PMCID: PMC5191016 DOI: 10.3390/s16122035] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2016] [Revised: 11/07/2016] [Accepted: 11/25/2016] [Indexed: 11/28/2022]
Abstract
This paper proposes a neural stimulation device integrated with a silicon nanowire (SiNW)-based photodetection circuit for the activation of neurons with light. The proposed device is comprised of a voltage divider and a current driver in which SiNWs are used as photodetector and field-effect transistors; it has the functions of detecting light, generating a stimulation signal in proportion to the light intensity, and transmitting the signal to a micro electrode. To show the applicability of the proposed neural stimulation device as a high-resolution retinal prosthesis system, a high-density neural stimulation device with a unit cell size of 110×110 μm and a resolution of 32×32 was fabricated on a flexible film with a thickness of approximately 50 μm. Its effectiveness as a retinal stimulation device was then evaluated using a unit cell in an in vitro animal experiment involving the retinal tissue of retinal Degeneration 1 (rd1) mice. Experiments wherein stimulation pulses were applied to the retinal tissues successfully demonstrate that the number of spikes in neural response signals increases in proportion to light intensity.
Collapse
Affiliation(s)
- Suk Won Jung
- ISRC/ASRI, Department of Electrical and Computer Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea.
- Human Care System Research Center, Convergence System R&D Division, Korea Electronics Technology Institute, 25 Saenari-ro, Bundang-gu, Seongnam-si, Gyeonggi-do 13509, Korea.
| | - Jong Yoon Shin
- ISRC/ASRI, Department of Electrical and Computer Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea.
| | - Kilwha Pi
- ISRC/ASRI, Department of Electrical and Computer Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea.
| | - Yong Sook Goo
- Department of Physiology, College of Medicine, Chungbuk National University, 1 Chungdae-ro, Seowon-gu, Cheongju, Chungbuk 28644, Korea.
| | - Dong-Il Dan Cho
- ISRC/ASRI, Department of Electrical and Computer Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea.
| |
Collapse
|
38
|
Halupka KJ, Shivdasani MN, Cloherty SL, Grayden DB, Wong YT, Burkitt AN, Meffin H. Prediction of cortical responses to simultaneous electrical stimulation of the retina. J Neural Eng 2016; 14:016006. [DOI: 10.1088/1741-2560/14/1/016006] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
39
|
Eleftheriou CG, Zimmermann JB, Kjeldsen HD, David-Pur M, Hanein Y, Sernagor E. Carbon nanotube electrodes for retinal implants: A study of structural and functional integration over time. Biomaterials 2016; 112:108-121. [PMID: 27760395 PMCID: PMC5123641 DOI: 10.1016/j.biomaterials.2016.10.018] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Revised: 10/08/2016] [Accepted: 10/11/2016] [Indexed: 12/15/2022]
Abstract
The choice of electrode material is of paramount importance in neural prosthetic devices. Electrodes must be biocompatible yet able to sustain repetitive current injections in a highly corrosive environment. We explored the suitability of carbon nanotube (CNT) electrodes to stimulate retinal ganglion cells (RGCs) in a mouse model of outer retinal degeneration. We investigated morphological changes at the bio-hybrid interface and changes in RGC responses to electrical stimulation following prolonged in vitro coupling to CNT electrodes. We observed gradual remodelling of the inner retina to incorporate CNT assemblies. Electrophysiological recordings demonstrate a progressive increase in coupling between RGCs and the CNT electrodes over three days, characterized by a gradual decrease in stimulation thresholds and increase in cellular recruitment. These results provide novel evidence for time-dependent formation of viable bio-hybrids between CNTs and the retina, demonstrating that CNTs are a promising material for inclusion in retinal prosthetic devices.
Collapse
Affiliation(s)
- Cyril G Eleftheriou
- Institute of Neuroscience, Faculty of Medical Sciences, Newcastle University, Framlington Place, Newcastle-upon-Tyne, NE2 4HH, United Kingdom
| | - Jonas B Zimmermann
- Institute of Neuroscience, Faculty of Medical Sciences, Newcastle University, Framlington Place, Newcastle-upon-Tyne, NE2 4HH, United Kingdom
| | - Henrik D Kjeldsen
- Institute of Neuroscience, Faculty of Medical Sciences, Newcastle University, Framlington Place, Newcastle-upon-Tyne, NE2 4HH, United Kingdom
| | - Moshe David-Pur
- School of Electrical Engineering, Tel-Aviv University, Ramat-Aviv, Tel-Aviv, 69978, Israel
| | - Yael Hanein
- School of Electrical Engineering, Tel-Aviv University, Ramat-Aviv, Tel-Aviv, 69978, Israel
| | - Evelyne Sernagor
- Institute of Neuroscience, Faculty of Medical Sciences, Newcastle University, Framlington Place, Newcastle-upon-Tyne, NE2 4HH, United Kingdom.
| |
Collapse
|
40
|
Roux S, Matonti F, Dupont F, Hoffart L, Takerkart S, Picaud S, Pham P, Chavane F. Probing the functional impact of sub-retinal prosthesis. eLife 2016; 5. [PMID: 27549126 PMCID: PMC4995098 DOI: 10.7554/elife.12687] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Accepted: 07/07/2016] [Indexed: 11/27/2022] Open
Abstract
Retinal prostheses are promising tools for recovering visual functions in blind patients but, unfortunately, with still poor gains in visual acuity. Improving their resolution is thus a key challenge that warrants understanding its origin through appropriate animal models. Here, we provide a systematic comparison between visual and prosthetic activations of the rat primary visual cortex (V1). We established a precise V1 mapping as a functional benchmark to demonstrate that sub-retinal implants activate V1 at the appropriate position, scalable to a wide range of visual luminance, but with an aspect-ratio and an extent much larger than expected. Such distorted activation profile can be accounted for by the existence of two sources of diffusion, passive diffusion and activation of ganglion cells’ axons en passant. Reverse-engineered electrical pulses based on impedance spectroscopy is the only solution we tested that decreases the extent and aspect-ratio, providing a promising solution for clinical applications. DOI:http://dx.doi.org/10.7554/eLife.12687.001 One of the most common causes of blindness is a disorder called retinitis pigmentosa. In a healthy eye, the surface at the back of the eye – called the retina – contains cells called photoreceptors that detect light and convert it into electrical signals for the brain to process. In people with retinitis pigmentosa, these photoreceptor cells die off gradually, which leads to loss of vision. The only treatment available for retinitis pigmentosa is to have an artificial retina implanted into the eye. The artificial retina consists of an array of tiny electrodes, which take over from the damaged photoreceptors and generate electrical signals. The person with the implant perceives these electrical signals as bright flashes called “phosphenes”. However, the phosphenes are too large and imprecise to provide the person with vision that is good enough for tasks such as walking unaided or reading. To find out why artificial retinas produce such poor resolution, Roux et al. compared how a rat’s brain responds to either natural visual stimuli or activation of implanted an array of micro-electrodes. Both the micro-electrodes and the natural stimuli activated the same areas of the brain. However, the micro-electrodes produced larger and more elongated patterns of activation. This is because the electrical currents generated by the micro-electrodes diffused throughout the retinal tissue and activated other neurons besides those intended. To overcome this problem, Roux et al. tested different ways of stimulating the micro-electrodes in order to identify those that induce the desired patterns of brain activity. This approach – known as reverse engineering – did indeed improve the performance of the micro-electrode array. The next step is to extend these findings, which were obtained in healthy rats, to non-human primates or animal models of retinitis pigmentosa to better understand the condition in humans. In addition, combining the current approach with other existing techniques should further improve the vision that can be achieved with artificial retinas. DOI:http://dx.doi.org/10.7554/eLife.12687.002
Collapse
Affiliation(s)
- Sébastien Roux
- Institut de Neurosciences de la Timone, CNRS, Aix-Marseille Université, Marseille, France
| | - Frédéric Matonti
- Institut de Neurosciences de la Timone, CNRS, Aix-Marseille Université, Marseille, France.,Ophthalmology Department, Aix Marseille Université, Hôpital Nord,Hôpital de la Timone, Marseille, France
| | - Florent Dupont
- CEA-LETI, Grenoble, France.,Université Grenoble Alpes, Grenoble, France
| | - Louis Hoffart
- Institut de Neurosciences de la Timone, CNRS, Aix-Marseille Université, Marseille, France.,Ophthalmology Department, Aix Marseille Université, Hôpital Nord,Hôpital de la Timone, Marseille, France
| | - Sylvain Takerkart
- Institut de Neurosciences de la Timone, CNRS, Aix-Marseille Université, Marseille, France
| | - Serge Picaud
- Inserm, UMRS-986, Institut de la vision, Paris, France
| | - Pascale Pham
- CEA-LETI, Grenoble, France.,Université Grenoble Alpes, Grenoble, France
| | - Frédéric Chavane
- Institut de Neurosciences de la Timone, CNRS, Aix-Marseille Université, Marseille, France
| |
Collapse
|
41
|
Yue L, Weiland JD, Roska B, Humayun MS. Retinal stimulation strategies to restore vision: Fundamentals and systems. Prog Retin Eye Res 2016; 53:21-47. [DOI: 10.1016/j.preteyeres.2016.05.002] [Citation(s) in RCA: 173] [Impact Index Per Article: 21.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Revised: 05/13/2016] [Accepted: 05/21/2016] [Indexed: 11/28/2022]
|
42
|
Properties of Retinal Precursor Cells Grown on Vertically Aligned Multiwalled Carbon Nanotubes Generated for the Modification of Retinal Implant-Embedded Microelectrode Arrays. J Ophthalmol 2016; 2016:2371021. [PMID: 27200182 PMCID: PMC4856943 DOI: 10.1155/2016/2371021] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Accepted: 04/04/2016] [Indexed: 12/27/2022] Open
Abstract
Background. To analyze the biocompatibility of vertically aligned multiwalled carbon nanotubes (MWCNT), used as nanomodification to optimize the properties of prostheses-embedded microelectrodes that induce electrical stimulation of surviving retinal cells. Methods. MWCNT were synthesized on silicon wafers. Their growth was achieved by iron particles (Fe) or mixtures of iron-platinum (Fe-Pt) and iron-titanium (Fe-Ti) acting as catalysts. Viability, growth, adhesion, and gene expression of L-929 and retinal precursor (R28) cells were analyzed after nondirect and direct contact. Results. Nondirect contact had almost no influence on cell growth, as measured in comparison to reference materials with defined levels of cytotoxicity. Both cell types exhibited good proliferation properties on each MWCNT-coated wafer. Viability ranged from 95.9 to 99.8%, in which better survival was observed for nonfunctionalized MWCNT generated with the Fe-Pt and Fe-Ti catalyst mixtures. R28 cells grown on the MWCNT-coated wafers showed a decreased gene expression associated with neural and glial properties. Expression of the cell cycle-related genes CCNC, MYC, and TP53 was slightly downregulated. Cultivation on plasma-treated MWCNT did not lead to additional changes. Conclusions. All tested MWCNT-covered slices showed good biocompatibility profiles, confirming that this nanotechnology is a promising tool to improve prostheses bearing electrodes which connect with retinal tissue.
Collapse
|
43
|
Im M, Fried SI. Temporal properties of network-mediated responses to repetitive stimuli are dependent upon retinal ganglion cell type. J Neural Eng 2016; 13:025002. [PMID: 26905231 PMCID: PMC4931047 DOI: 10.1088/1741-2560/13/2/025002] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To provide artificially-elicited vision that is temporally dynamic, retinal prosthetic devices will need to repeatedly stimulate retinal neurons. However, given the diversity of physiological types of retinal ganglion cells (RGCs) as well as the heterogeneity of their responses to electric stimulation, temporal properties of RGC responses have not been adequately investigated. Here, we explored the cell type dependence of network-mediated RGC responses to repetitive electric stimulation at various stimulation rates. APPROACH We examined responses of ON and OFF types of RGCs in the rabbit retinal explant to five consecutive stimuli with varying inter-stimulus intervals (10-1000 ms). Each stimulus was a 4 ms long monophasic sinusoidal cathodal current, which was applied epiretinally via a conical electrode. Spiking activity of targeted RGCs was recorded using a cell-attached patch electrode. MAIN RESULTS ON and OFF cells had distinct responses to repetitive stimuli. Consistent with earlier studies, OFF cells always generated reduced responses to subsequent stimuli compared to responses to the first stimulus. In contrast, a new stimulus to ON cells suppressed all pending/ongoing responses from previous stimuli and initiated its own response that was remarkably similar to the response from a single stimulus in isolation. This previously unreported 'reset' behavior was observed exclusively and consistently in ON cells. These contrasts between ON and OFF cells created a range of stimulation rates (4-7 Hz) that maximized the ratio of the responses arising in ON versus OFF cells. SIGNIFICANCE Previous clinical testing reported that subjects perceive bright phosphenes (ON responses) and also prefer stimulation rates of 5-7 Hz. Our results suggest that responses of ON cells are weak at high rates of stimulation (> ∼7 Hz) due to the reset while responses of OFF cells are strong at low rates (< ∼4 Hz) due to reduced desensitization, both reducing the ratio of ON to OFF responses. In combination with previous results indicating that responses in ON cells more closely match physiological patterns (Im and Fried 2015 J. Physiol. 593 3577-96), our results offer a potential reason for the user preference of intermediate rates (5-7 Hz).
Collapse
Affiliation(s)
- Maesoon Im
- VA Boston Healthcare System, 150 South Huntington Avenue, Boston, MA 02130
- Department of Neurosurgery, Massachusetts General Hospital and Harvard Medical School, 50 Blossom Street, Boston, MA 02114
| | - Shelley I. Fried
- VA Boston Healthcare System, 150 South Huntington Avenue, Boston, MA 02130
- Department of Neurosurgery, Massachusetts General Hospital and Harvard Medical School, 50 Blossom Street, Boston, MA 02114
| |
Collapse
|
44
|
Wong YT, Halupka K, Kameneva T, Cloherty SL, Grayden DB, Burkitt AN, Meffin H, Shivdasani MN. Spectral distribution of local field potential responses to electrical stimulation of the retina. J Neural Eng 2016; 13:036003. [DOI: 10.1088/1741-2560/13/3/036003] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
45
|
Abstract
This review focuses on a description of the Argus II retinal prosthesis system (Argus II; Second Sight Medical Products, Sylmar, CA) that was approved for humanitarian use by the FDA in 2013 in patients with retinitis pigmentosa with bare or no light perception vision. The article describes the components of Argus II, the studies on the implant, and future directions.
Collapse
Affiliation(s)
| | - Alex Yuan
- a Cole Eye Institute, Cleveland Clinic Foundation , Cleveland , Ohio , USA
| |
Collapse
|
46
|
Chhablani J, Jonnadula GB, Srinivasa Rao P, Venkata A, Jalali S. Choroidal thickness profile in Retinitis Pigmentosa - Correlation with outer retinal structures. Saudi J Ophthalmol 2015; 30:9-13. [PMID: 26949351 PMCID: PMC4759516 DOI: 10.1016/j.sjopt.2015.09.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2014] [Revised: 08/12/2015] [Accepted: 09/14/2015] [Indexed: 11/21/2022] Open
Abstract
Purpose To compare the choroidal thickness (CT) of subjects with Retinitis Pigmentosa (RP) with age-matched healthy subjects and to correlate the visual acuity with retinal parameters including central macular thickness (CMT), inner segment/outer segment junction (IS/OS junction) integrity, external limiting membrane (ELM) integrity and choroidal thickness in subjects with RP. Methods Eighty-eight eyes (69 patients) with typical RP and 188 eyes of 104 healthy subjects were enrolled between September 2012 and January 2013. All subjects underwent a comprehensive ocular examination including choroidal imaging using enhanced depth imaging with spectral domain optical coherence tomography. Outcome measures were CT difference between RP and age-matched healthy subjects; and correlation of various factors such CMT, IS/OS junction integrity, ELM integrity, and CT with visual acuity. Results Among RP subjects, mean age was 31.39 ± 13.4 years with a mean BCVA of 0.99 ± 0.94 logMAR. Mean spherical equivalent was −0.6 ± 1.6D. Mean CMT was 148.48 ± 119 μm. Mean subfoveal CT was 296.9 ± 72 μm. Mean IS/OS and ELM integrity was 42.2 ± 46.6% and 43.75 ± 45.7%, respectively. The mean age was 40.0 ± 13.5 years with a mean spherical equivalent of 0.18 ± 0.6D for the normal age-matched healthy group. Mean subfoveal CT was 283.1 ± 47.8 μm. CT at various locations in patients of various ages in the RP group did not show any statistical significant difference (P = ≫0.05) in comparison with age-matched healthy subjects. On multivariate regression, ELM percentage integrity had the strongest association with best corrected visual acuity, followed by IS/OS junction percentage integrity. Subfoveal choroidal thickness had very weak correlation with visual acuity as well other retinal parameters. There was a significant difference in the outer retinal structure integrity (p = 0.002) and CMT (p = 0.02) between the eyes with good (⩾20/200) and poor vision (<20/200), but not in subfoveal choroidal thickness (p = 0.3). Conclusions Our study results did not show any significant difference in choroidal thickness between subjects with RP and age-matched healthy subjects. Choroidal thickness correlated better with the age but not with the vision or outer retinal structures in eyes with RP. Outer retinal structure integrity and CMT had a better correlation with visual acuity.
Collapse
Affiliation(s)
- Jay Chhablani
- Smt. Kanuri Santhamma Retina Vitreous Centre, L.V. Prasad Eye Institute, Kallam Anji Reddy Campus, L.V. Prasad Marg, Banjara Hills, Hyderabad 500 034, Andhra Pradesh, India
- Corresponding author.
| | - Ganesh Babu Jonnadula
- Smt. Kanuri Santhamma Retina Vitreous Centre, L.V. Prasad Eye Institute, Kallam Anji Reddy Campus, L.V. Prasad Marg, Banjara Hills, Hyderabad 500 034, Andhra Pradesh, India
| | - P. Srinivasa Rao
- L.V. Prasad Eye Institute, Kode Venkatadri Chowdary Campus, Tadigadapa, Vijayawada 521137, Andhra Pradesh, India
| | - Amarnath Venkata
- Smt. Kanuri Santhamma Retina Vitreous Centre, L.V. Prasad Eye Institute, Kallam Anji Reddy Campus, L.V. Prasad Marg, Banjara Hills, Hyderabad 500 034, Andhra Pradesh, India
| | - Subhadra Jalali
- Smt. Kanuri Santhamma Retina Vitreous Centre, L.V. Prasad Eye Institute, Kallam Anji Reddy Campus, L.V. Prasad Marg, Banjara Hills, Hyderabad 500 034, Andhra Pradesh, India
| |
Collapse
|
47
|
Fine I, Boynton GM. Pulse trains to percepts: the challenge of creating a perceptually intelligible world with sight recovery technologies. Philos Trans R Soc Lond B Biol Sci 2015; 370:20140208. [PMID: 26240423 PMCID: PMC4528820 DOI: 10.1098/rstb.2014.0208] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/13/2015] [Indexed: 11/12/2022] Open
Abstract
An extraordinary variety of sight recovery therapies are either about to begin clinical trials, have begun clinical trials, or are currently being implanted in patients. However, as yet we have little insight into the perceptual experience likely to be produced by these implants. This review focuses on methodologies, such as optogenetics, small molecule photoswitches and electrical prostheses, which use artificial stimulation of the retina to elicit percepts. For each of these technologies, the interplay between the stimulating technology and the underlying neurophysiology is likely to result in distortions of the perceptual experience. Here, we describe some of these potential distortions and discuss how they might be minimized either through changes in the encoding model or through cortical plasticity.
Collapse
Affiliation(s)
- Ione Fine
- Department of Psychology, University of Washington, Seattle, WA, USA
| | | |
Collapse
|
48
|
Properties of electrically evoked potentials activated by optic nerve stimulation with penetrating electrodes of different modes in rabbits. Graefes Arch Clin Exp Ophthalmol 2015; 253:2171-80. [DOI: 10.1007/s00417-015-3121-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Revised: 07/16/2015] [Accepted: 07/18/2015] [Indexed: 10/23/2022] Open
|
49
|
Yan Y, Sui X, Liu W, Lu Y, Cao P, Ma Z, Chen Y, Chai X, Li L. Spatial characteristics of evoked potentials elicited by a MEMS microelectrode array for suprachoroidal-transretinal stimulation in a rabbit. Graefes Arch Clin Exp Ophthalmol 2015; 253:1515-28. [PMID: 25981117 DOI: 10.1007/s00417-015-3027-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2014] [Revised: 03/26/2015] [Accepted: 04/20/2015] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Suprachoroidal-transretinal stimulation (STS) can potentially restore vision. This study investigated the spatial characteristics of cortical electrical evoked potentials (EEPs) elicited by STS. METHODS A 4 × 4 thin-film platinum microelectrode stimulating array (200 μm electrode diameter and 400 μm center-to-center distance) was fabricated by a micro-electro-mechanical systems (MEMS) techniques and implanted into the suprachoroidal space of albino rabbits. RESULTS The current threshold to elicit reliable EEPs by a single electrode was 41.6 ± 12.6 μA, corresponding to a 66.2 ± 20.1 μC · cm(-2) charge density per phase, which was lower than the reported safety limits. Spatially differentiated cortical responses could be evoked by STS through different rows or columns of electrical stimulation; furthermore, shifts in the location of the maximum cortical activities were consistent with cortical visuotopic maps; increasing the number of simultaneously stimulating electrodes increased the response amplitudes of EEPs and expanded the spatial spread as well. In addition, long-term implantation and electrical stimulation of the MEMS electrode array in suprachoroidal space are necessary to evaluate systematically the safety and biocompatibility of this approach. CONCLUSIONS This study indicates that the STS approach by a MEMS-based platinum electrode array is a feasible alternative for visual restoration, and relatively high spatial discrimination may be achieved.
Collapse
Affiliation(s)
- Yan Yan
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China,
| | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Matonti F, Roux S, Denis D, Picaud S, Chavane F. [Blindness and visual rehabilitation]. J Fr Ophtalmol 2015; 38:93-102. [PMID: 25595628 DOI: 10.1016/j.jfo.2014.06.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2014] [Revised: 06/23/2014] [Accepted: 06/30/2014] [Indexed: 10/24/2022]
Abstract
Blindness and visual impairment are a major public health problem all over the world and in all societies. A large amount of basic science and clinical research aims to rehabilitate patients and help them become more independent. Various methods are explored from cell and molecular therapy to prosthetic interfaces. We review the various treatment alternatives, describing their results and their limitations.
Collapse
Affiliation(s)
- F Matonti
- Service d'ophtalmologie, hôpital Nord, chemin de Bourrely, 13915 Marseille cedex 20, France; Équipe InViBe, institut de neurosciences de la Timone, UMR 7289 CNRS, Aix-Marseille université, 13402 Marseille cedex 20, France.
| | - S Roux
- Équipe InViBe, institut de neurosciences de la Timone, UMR 7289 CNRS, Aix-Marseille université, 13402 Marseille cedex 20, France
| | - D Denis
- Service d'ophtalmologie, hôpital Nord, chemin de Bourrely, 13915 Marseille cedex 20, France; Équipe InViBe, institut de neurosciences de la Timone, UMR 7289 CNRS, Aix-Marseille université, 13402 Marseille cedex 20, France
| | - S Picaud
- Inserm, U968, CNRS, UMR 7210, institut de la vision, UPMC université Paris 06, 75012 Paris, France
| | - F Chavane
- Équipe InViBe, institut de neurosciences de la Timone, UMR 7289 CNRS, Aix-Marseille université, 13402 Marseille cedex 20, France
| |
Collapse
|