1
|
Nieuwenburg SA, Bruisten SM, Heijman T, Vermeulen W, van Dam AP, Schim van der Loeff MF, de Vries HJC. Use of Home-Based Self-Collected Dried Blood Spots to Test for Syphilis, Human Immunodeficiency Virus, Hepatitis C and B Virus Infections and Measuring Creatinine Concentration. Sex Transm Dis 2024; 51:283-288. [PMID: 38430511 DOI: 10.1097/olq.0000000000001941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2024]
Abstract
INTRODUCTION Home-based self-collected dried blood spot (DBS) sampling could simplify sexual health and preexposure prophylaxis care and reduce sexually transmitted infections (STIs) clinic visits for men who have sex with men (MSM). We compared the performance of DBS to venipuncture collected blood samples to test four STIs and creatinine concentration. METHODS We invited MSM clients of the Amsterdam STI clinic to participate. Routinely collected peripheral blood was tested for syphilis treponemal antibody, HIV (HIV Ag/Ab), HCV (antibodies), HBV (HBsAg) and creatinine concentration. Participants received a home kit for DBS sampling, a return envelope and a questionnaire to evaluate the acceptability, feasibility and usability of DBS, measured on 5-point Likert scales, 1 representing complete disagreement and 5 complete agreement. We assessed sensitivity and specificity of DBS versus peripheral blood-based testing. RESULTS In 2020 to 2021, we included 410 participants; 211 (51.5%) returned a completed DBS card, 117 (28.5%) returned a partially filled card and 82 (20.0%) did not return a card. The sensitivity for syphilis was 90.8% and the specificity 84.3%. For both HIV Ag/Ab and HBsAg, the sensitivity and specificity were 100.0%. The sensitivity for HCV antibody was 80.0%, and the specificity was 99.2%. The DBS creatinine concentration was a mean of 5.3 μmol/L higher than in venipuncture obtained plasma. Participants' median willingness to take a future DBS was 4 (interquartile range, 3-5). DISCUSSION Dried blood spot may be an acceptable method among MSM for STI testing and creatinine follow-up during preexposure prophylaxis use. However, collecting enough blood on DBS cards was a challenge, and sensitivities for syphilis and HCV serology were too low.
Collapse
Affiliation(s)
| | | | - T Heijman
- From the Department of Infectious Diseases, Public Health Service Amsterdam, Amsterdam, the Netherlands
| | - W Vermeulen
- From the Department of Infectious Diseases, Public Health Service Amsterdam, Amsterdam, the Netherlands
| | | | | | | |
Collapse
|
2
|
Mane A, Agarwal R, Bajpai M, Sane S, Vidhate P, Rakshit P, Madan P, Gogia H, Abraham P, Kabra S, Gupta E. Validation of dried blood spot for serological diagnosis of Hepatitis B and C: a multicentric study. Diagn Microbiol Infect Dis 2024; 108:116108. [PMID: 38000329 DOI: 10.1016/j.diagmicrobio.2023.116108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 10/06/2023] [Accepted: 10/12/2023] [Indexed: 11/26/2023]
Abstract
The present study aimed to determine diagnostic performance of dried blood spot (DBS) for the detection of Hepatitis B surface antigen (HBsAg) and Hepatitis C virus antibodies (anti-HCV) using CLIA at 3 different laboratories across India. DBS can serve as a simple and convenient alternative to plasma/serum for HBsAg detection. However for anti-HCV, site-specific validation of the assay is warranted.
Collapse
Affiliation(s)
- Arati Mane
- Division of Microbiology, ICMR- NARI, Pune, India
| | - Reshu Agarwal
- Department of Clinical Virology, Institute of Liver and Biliary Sciences, New Delhi, India
| | - Meenu Bajpai
- Department of Transfusion Medicine, Institute of Liver and Biliary Sciences, New Delhi, India
| | - Suvarna Sane
- Division of Epidemiology and Biostatistics, ICMR- NARI, Pune, India
| | - Pallavi Vidhate
- Division of Epidemiology and Biostatistics, ICMR- NARI, Pune, India
| | | | - Preeti Madan
- National Centre for Disease Control, New Delhi, India
| | - Hema Gogia
- National Centre for Disease Control, New Delhi, India
| | - Priya Abraham
- Department of Virology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Sandhya Kabra
- National Centre for Disease Control, New Delhi, India
| | - Ekta Gupta
- Department of Clinical Virology, Institute of Liver and Biliary Sciences, New Delhi, India.
| |
Collapse
|
3
|
Virtudazo MCC, Aquino JB, Arellano RNB, Fortes RA, Kaw RC, Tantengco OAG. The role of dried blood spot tests in the detection of hepatitis B infection: A systematic review. J Viral Hepat 2024; 31:35-46. [PMID: 37789709 DOI: 10.1111/jvh.13890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 09/23/2023] [Indexed: 10/05/2023]
Abstract
Hepatitis B remains a public health problem worldwide despite vaccine availability. Although the existing diagnostic tools help detect the infection, logistics support and limited resources and technologies affect their usefulness and reliability in developing countries. This systematic review evaluated the performance of dried blood spots (DBS) as a collection and storage tool for diagnosing an hepatitis B virus (HBV) infection. A comprehensive search using OVID, Scopus and CINAHL databases was performed to collate articles published up to April 2023 that detected Hepatitis B infections using DBS. Five reviewers independently performed identification, screening, quality assessment and data extraction. A qualitative synthesis of the included studies was conducted. Of the 402 articles, 78 met the inclusion criteria. The results show that most studies focused on populations with known HBV, HCV and/or HIV status. Approximately half (49%) of the included studies utilized the Whatman Protein Saver Card for DBS collection. The DBS samples were then predominantly stored in room temperature conditions. In line with this, storage conditions influenced the concentration and stability of the analyte from the DBS samples, affecting the accuracy of downstream diagnostic methods. ELISA methods, using hepatitis B surface antigen (HBsAg) as an HBV marker, were the most widely used diagnostic tool for detecting HBV infection in DBS samples. The simplicity and cost-effectiveness of the ELISA technique highlight its potential to be used in low-resource settings. In line with this, the detection of HBsAg using an ELISA immunoassay had higher sensitivity (85.6%-100%), and specificity (95%-100%) ranges as compared to other target molecules and methods. Although this review only performed a qualitative analysis, DBS offers a promising method for collecting and storing blood samples; however, the standardization of sampling, storing conditions and diagnostic techniques is required to ensure sustainable application.
Collapse
Affiliation(s)
| | - Jericho B Aquino
- Department of Biology, College of Arts and Sciences, University of the Philippines Manila, Manila, Philippines
| | - Rose Nicole B Arellano
- Department of Biology, College of Arts and Sciences, University of the Philippines Manila, Manila, Philippines
| | - Robert A Fortes
- Department of Biology, College of Arts and Sciences, University of the Philippines Manila, Manila, Philippines
| | - Raphaela C Kaw
- Department of Biology, College of Arts and Sciences, University of the Philippines Manila, Manila, Philippines
| | - Ourlad Alzeus G Tantengco
- Department of Biology, College of Arts and Sciences, University of the Philippines Manila, Manila, Philippines
- Department of Physiology, College of Medicine, University of the Philippines Manila, Manila, Philippines
- Department of Biology, College of Science, De La Salle University, Manila, Philippines
| |
Collapse
|
4
|
McAuliffe G, Gerber A, Chhibber A, Fisher M, Saxton P, Fisher T, Blakiston M, Forster R. Evaluating the sensitivity and specificity of dried blood spots for serological testing of HIV, syphilis, hepatitis B and C Elecsys assays on the Roche Cobas system. Pathology 2023; 55:1000-1003. [PMID: 37690864 DOI: 10.1016/j.pathol.2023.06.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 06/05/2023] [Accepted: 06/16/2023] [Indexed: 09/12/2023]
Abstract
This study was performed to validate a dried blood spot (DBS) method for the serological screening of HIV, syphilis, hepatitis B and C. It included 250 paired DBS and serum samples and 116 unpaired DBS samples from 366 unique patients from two laboratories between 8 October and 2 November 2021. As determined by original test request, these were tested using a DBS method for HIV Ag/Ab (n=216), anti-treponemal Ab (n=166), hepatitis B sAg (n=100), and hepatitis C Ab (n=100) Elecsys assays on the Roche Cobas automated platform. Using the manufacturer's (serum) cut-off for reactivity ('positivity'), the sensitivity and specificity of DBS testing compared with serum were: for HIV Ag/Ab 100% and 100%, for anti-treponemal Ab 68.3% and 100%, for hepatitis B sAg 95.9% and 100%, and for hepatitis C Ab 84.0% and 100%, respectively. Adjusting the assay cut-off using receiver operator curve analysis increased sensitivity of DBS testing for anti-treponemal Ab to 90.0%, hepatitis B sAg to 97.9% and hepatitis C Ab to 94.0% whilst maintaining specificity of 98.8%, 100% and 100%, respectively. With optimisation of assay cut-off, DBS can perform comparably with serum for serological testing for HIV, syphilis, hepatitis B and C and may be a valuable tool in increasing access to testing in New Zealand.
Collapse
Affiliation(s)
- Gary McAuliffe
- Labtests, Carbine Road, Mount Wellington, Auckland, New Zealand; LabPLUS, Te Whatu Ora, Te Toka Tumai, Grafton, Auckland, New Zealand.
| | - Adri Gerber
- Labtests, Carbine Road, Mount Wellington, Auckland, New Zealand
| | - Aakash Chhibber
- LabPLUS, Te Whatu Ora, Te Toka Tumai, Grafton, Auckland, New Zealand
| | | | - Peter Saxton
- University of Auckland, Grafton, Auckland, New Zealand
| | - Tony Fisher
- University of Auckland, Grafton, Auckland, New Zealand
| | - Matt Blakiston
- Labtests, Carbine Road, Mount Wellington, Auckland, New Zealand; LabPLUS, Te Whatu Ora, Te Toka Tumai, Grafton, Auckland, New Zealand
| | - Rose Forster
- Labtests, Carbine Road, Mount Wellington, Auckland, New Zealand; University of Auckland, Grafton, Auckland, New Zealand
| |
Collapse
|
5
|
Vanroye F, Van den Bossche D, Vercauteren K. Prospective Laboratory Evaluation of the cobas Plasma Separation Card for HIV and Treponema pallidum Antibody Analysis. Sex Transm Dis 2023; 50:764-769. [PMID: 37824788 DOI: 10.1097/olq.0000000000001863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2023]
Abstract
BACKGROUND The cobas Plasma Separation Card (PSC; Roche Diagnostics) was developed for HIV viral load testing. This study evaluates the performance of HIV and Treponema pallidum (Tp) antibody (Ab) detection on PSCs as an alternative to dried blood spots (DBSs). METHODS EDTA whole blood samples were collected from HIV-positive (n = 100), HIV-negative (n = 50), Tp-positive (n = 100), and Tp-negative patients (n = 50) and spotted on DBS and PSC. Antibody detection performance was evaluated for HIV Ab using the Genscreen ULTRA HIV Ag-Ab test (Bio-Rad) and for Tp Ab using the Syphilis Total Ab test (Bio-Rad). Plasma was used as a reference specimen. RESULTS Receiver operating characteristic curve analysis for DBS and PSC generated areas under the curve (AUC + 95% confidence interval) of 0.985 (0.960-1.000) and 0.987 (0.973-1.000) for HIV Ab and 1.000 (1.000-1.000) and 0.996 (0.983-1.000) for Tp Ab, respectively. Receiver operating characteristic areas under the curve were not significantly different between DBS and PSC for HIV or TP Ab. At selected cutoff values rendering at least 99% sensitivity for HIV Ab detection, the specificity was 96% on DBS and 68% on PSC. For Tp Ab detection at 90% sensitivity, 100% specificity is reached on both DBS and PSC (exceeding the required 95%). However, the median quantitative HIV and Tp Ab signal of positive samples significantly decreased in PSC compared with DBS and plasma. CONCLUSIONS Although receiver operating characteristic analysis does not seem to indicate significant differences in performance between DBS and PSC, the significant reduction in quantitative Ab detection signal dictates card composition optimization before its use for HIV and Tp Ab detection can be advised.
Collapse
Affiliation(s)
- Fien Vanroye
- From the Clinical Reference Laboratory/AIDS Reference Laboratory
| | | | | |
Collapse
|
6
|
Troyano-Hernáez P, Herrador P, Gea F, Romero-Hernández B, Reina G, Albillos A, Galán JC, Holguín Á. Impact of storage time in dried blood samples (DBS) and dried plasma samples (DPS) for point-of-care hepatitis C virus (HCV) RNA quantification and HCV core antigen detection. Microbiol Spectr 2023; 11:e0174823. [PMID: 37655908 PMCID: PMC10581200 DOI: 10.1128/spectrum.01748-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Accepted: 07/03/2023] [Indexed: 09/02/2023] Open
Abstract
The scale-up of hepatitis C virus (HCV) diagnosis and treatment requires affordable and simple tools to improve access to care, especially in low- and middle-income settings with limited infrastructure or high-risk populations. Dried blood and plasma samples (DBS and DPS) are useful alternative for hepatitis C detection in settings lacking adequate infrastructure. We evaluated the performance of DBS and DPS vs plasma in a point-of-care HCV RNA quantitative assay (Xpert HCV Viral Load-Cepheid), and compared HCV core antigen (HCVcAg) detection by the Architect HCV core antigen assay (Abbott) in DBS vs serum. The dried samples were stored at room temperature for different storage times to reproduce the time from sampling to testing in settings with centralized diagnosis or when testing mobile populations. HCV RNA quantification in DBS and DPS presented 100% sensitivity and specificity and a high correlation for up to 3 months of storage. HCV viremia showed a mean decrease of 0.5 log10 IU/mL (DBS) and 0.3 log10 IU/mL (DPS) for storage times up to 1 month. Architect HCVcAg detection presented high sensitivity/specificity (96%/100%) in DBS tested immediately after sampling, decreasing to 86% sensitivity after 7 days of storage. However, sensitivity increased when an optimized cut-off was applied for each storage time. We conclude that DBS and DPS are suitable samples for HCV RNA detection and quantification, being DPS more reliable for shorter storage times. DBS can be also used for HCVcAg qualitative detection and the sensitivity can be increased when adjusting the cut-off values. IMPORTANCE Hepatitis C infection remains a global burden despite the effectiveness of antivirals. In the WHO roadmap to accomplish HCV elimination by 2030, HCV diagnosis is one of the main targets. However, identifying patients in resource-limited settings and high-risk populations with limited access to healthcare remains a challenge and requires innovative approaches that allow decentralized testing. The significance of our research is in verifying the good performance of dried samples for HCV diagnosis using two different diagnostics assays and considering the effect of room temperature storage in this sample format. We confirmed dried samples are an interesting alternative for HCV screening and reflex testing in resource-limited settings or high-risk populations.
Collapse
Affiliation(s)
- Paloma Troyano-Hernáez
- Microbiology Department, HIV-1 Molecular Epidemiology Laboratory, Ramón y Cajal University Hospital-Ramón y Cajal Institute for Health Research (IRYCIS) and RITIP-CoRISpe, Madrid, Spain
| | - Pedro Herrador
- Microbiology Department, HIV-1 Molecular Epidemiology Laboratory, Ramón y Cajal University Hospital-Ramón y Cajal Institute for Health Research (IRYCIS) and RITIP-CoRISpe, Madrid, Spain
- Microbiology Department, Ramón y Cajal University Hospital-Ramón y Cajal Institute for Health Research (IRYCIS), Madrid, Spain
| | - Francisco Gea
- Gastroenterology Department, Ramón y Cajal University Hospital-Ramón y Cajal Institute for Health Research (IRYCIS), Madrid, Spain
| | - Beatriz Romero-Hernández
- Microbiology Department, Ramón y Cajal University Hospital-Ramón y Cajal Institute for Health Research (IRYCIS), Madrid, Spain
- Biomedical Research Center in Epidemiology and Public Health (CIBERESP), Madrid, Spain
| | - Gabriel Reina
- Microbiology Department, Clínica Universidad de Navarra, Pamplona, Spain
- ISTUN, Institute of Tropical Health, Universidad de Navarra, Pamplona, Spain
- IdiSNA, Navarra Institute for Health Research, Pamplona, Spain
| | - Agustín Albillos
- Gastroenterology Department, Ramón y Cajal University Hospital-Ramón y Cajal Institute for Health Research (IRYCIS), Madrid, Spain
- Biomedical Research Center on Liver and Digestive Diseases (CIBEREHD), Madrid, Spain
- University of Alcalá, Madrid, Spain
| | - Juan Carlos Galán
- Microbiology Department, Ramón y Cajal University Hospital-Ramón y Cajal Institute for Health Research (IRYCIS), Madrid, Spain
- Biomedical Research Center in Epidemiology and Public Health (CIBERESP), Madrid, Spain
| | - África Holguín
- Microbiology Department, HIV-1 Molecular Epidemiology Laboratory, Ramón y Cajal University Hospital-Ramón y Cajal Institute for Health Research (IRYCIS) and RITIP-CoRISpe, Madrid, Spain
- Microbiology Department, Ramón y Cajal University Hospital-Ramón y Cajal Institute for Health Research (IRYCIS), Madrid, Spain
- Biomedical Research Center in Epidemiology and Public Health (CIBERESP), Madrid, Spain
| |
Collapse
|
7
|
Modified ARCHITECT ® serologic assays enable plasma-level performance from dried blood spot samples. Biotechniques 2022; 73:193-203. [PMID: 36240056 DOI: 10.2144/btn-2022-0082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Dried blood spots (DBSs) provide an alternative sample input for serologic testing. We evaluated DBSs for the ARCHITECT® hepatitis B surface antigen (HBsAg) NEXT, hepatitis B e-antigen (HBeAg), anti-hepatitis B core antigen (anti-HBc II), HIV antigen/antibody (Ag/Ab) Combo and AdviseDx SARS-CoV-2 IgG II assays. Assay performance with DBSs was assessed with or without assay modification and compared with on-market assay with plasma samples. DBS stability was also determined. HBsAg NEXT and HIV Ag/Ab Combo assays using DBSs showed sensitivity and specificity comparable to that of on-market assays. Modified HBeAg, anti-HBc II and SARS-CoV-2 IgG II DBS assays achieved performance comparable to on-market assays. Use of DBSs as input for high-throughput serologic assays is expected to have significant implications for improving population surveillance and increasing access to diagnostic testing.
Collapse
|
8
|
Shaver ZM, Anderson M, Bhebhe L, Baruti K, Chogaa WT, Ngidi J, Mbangiwa T, Taua M, Setlhare DR, Melamu P, Phinius BB, Musonda R, Mine M, Moyo S, Gaseitsiwe S. Decreased hepatitis B virus vaccine response among HIV-positive infants compared with HIV-negative infants in Botswana. AIDS 2022; 36:755-762. [PMID: 35113045 PMCID: PMC7614825 DOI: 10.1097/qad.0000000000003183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES We sought to determine vaccine antibody titres and the prevalence of hepatitis B surface antigen (HBsAg) in both HIV-positive and HIV-negative infants born to HIV-positive mothers in Botswana. DESIGN This was a retrospective cross-sectional study using 449 archived dried blood spot samples from both HIV-positive and HIV-negative infants collected between 2016 and 2018. METHODS We screened dried blood spot samples for HBsAg and determined hepatitis B surface antibody titres. We determined hepatitis B virus (HBV) genotypes by amplifying 415 base-pairs of the surface region. RESULTS HIV-positive infants mounted a significantly lower immune response to the HBV vaccine (P < 0.001). Furthermore, a lower proportion of HIV-positive infants had protective hepatitis B surface antibody titres (74.5%) than HIV-negative infants (89.2%) (P < 0.001). HIV-positive infants were older and 50.9% of them had completed vaccination (P = 0.018). Of the 449 infant samples tested, three (0.67%) were positive for HBsAg. Of the three HBsAg-positive infants, two had protective titres (>10 mIU/ml). Two of the three HBV-positive infants were infected with genotype D3 and had no drug-resistance or escape mutations. CONCLUSION Vaccine response was lower among HIV-positive infants compared with HIV-negative infants. HBV infections were observed in both HIV-positive and HIV-negative infants in Botswana. Studies to investigate additional preventive strategies to reduce HBV mother-to-child transmission are recommended.
Collapse
Affiliation(s)
| | | | | | - Kabo Baruti
- Botswana Harvard AIDS Institute Partnership, Gaborone
- University of Botswana, Department of Biological Sciences, Gabarone, Botswana
| | - Wonderful T. Chogaa
- Botswana Harvard AIDS Institute Partnership, Gaborone
- Division of Human Genetics, Department of Pathology, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa
| | - Julia Ngidi
- Botswana Harvard AIDS Institute Partnership, Gaborone
- National Health Laboratory, Ministry of Health and Wellness, Gaborone, Botswana
| | | | - Modiri Taua
- Botswana Harvard AIDS Institute Partnership, Gaborone
- National Health Laboratory, Ministry of Health and Wellness, Gaborone, Botswana
| | - Ditiro R. Setlhare
- Botswana Harvard AIDS Institute Partnership, Gaborone
- National Health Laboratory, Ministry of Health and Wellness, Gaborone, Botswana
| | - Pinkie Melamu
- Botswana Harvard AIDS Institute Partnership, Gaborone
| | | | | | - Madisa Mine
- Botswana Harvard AIDS Institute Partnership, Gaborone
- National Health Laboratory, Ministry of Health and Wellness, Gaborone, Botswana
| | - Sikhulile Moyo
- Botswana Harvard AIDS Institute Partnership, Gaborone
- Department of Immunology and Infectious Diseases, Harvard T.H. Chan School of Public Health, Boston, Massachusetts, USA
| | - Simani Gaseitsiwe
- Botswana Harvard AIDS Institute Partnership, Gaborone
- Department of Immunology and Infectious Diseases, Harvard T.H. Chan School of Public Health, Boston, Massachusetts, USA
| |
Collapse
|
9
|
Evaluation of hepatitis C virus antibody assay using dried blood spot samples. Sci Rep 2022; 12:3763. [PMID: 35260691 PMCID: PMC8904514 DOI: 10.1038/s41598-022-07821-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 02/22/2022] [Indexed: 01/05/2023] Open
Abstract
Early diagnosis of hepatitis C virus (HCV) infection is essential for prompt initiation of treatment and prevention of transmission, yet several logistical barriers continue to limit access to HCV testing. Dried blood spot (DBS) technology involves a simple fingerstick that eliminates the need for trained personnel, and DBS can be stored and transported at room temperature. We evaluated the use of DBS whole blood samples in the modified Abbott ARCHITECT anti-HCV assay, comparing assay performance against the standard assay run using DBS and venous plasma samples. 144 HCV positive and 104 HCV negative matched venous plasma and whole blood specimens were selected from a retrospective study with convenience sampling in Cameroon. Results obtained using a modified volume DBS assay were highly correlated to the results of the standard assay run with plasma on clinical samples and dilution series (R2 = 0.71 and 0.99 respectively). The ARCHITECT Anti-HCV assay with input volume modification more accurately detects HCV antibodies in DBS whole blood samples with 100% sensitivity and specificity, while the standard assay had 90.97% sensitivity. The use of DBS has the potential to expand access to HCV testing to underserved or marginalized populations with limited access to direct HCV care.
Collapse
|
10
|
Bezerra CS, Portilho MM, Barbosa JR, de Azevedo CP, Mendonça ACDF, da Cruz JNM, Frota CC, do Lago BV, Villar LM. Dried blood spot sampling for hepatitis B virus quantification, sequencing and mutation detection. Sci Rep 2022; 12:1651. [PMID: 35102169 PMCID: PMC8803841 DOI: 10.1038/s41598-022-05264-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Accepted: 01/10/2022] [Indexed: 02/06/2023] Open
Abstract
Hepatitis B virus (HBV) diagnosis is performed on serum samples, but the access to this diagnosis is difficult in low-income regions. The use of dried blood spot (DBS) samples does not require special structure for collection, storage or transport. This study evaluates the use of DBS for detection, quantification and sequencing of HBV DNA using in-house techniques. Two study groups were included: 92 HBsAg + individuals and 49 negative controls. Serum and DBS samples were submitted to quantitative and qualitative in-house PCR for S/pol genes, sequencing and phylogenetic analyses. Total of 84 serum samples were successfully amplified. Of them, 63 paired DBS were also positive in qualitative PCR. Qualitative PCR in DBS presented a sensitivity of 75% and specificity of 100% (Kappa = 0.689). Quantitative PCR in DBS presented a detection limit of 852.5 copies/mL (250 IU/mL), sensitivity of 77.63% and specificity of 100% (Kappa = 0.731). A total of 63 serum samples and 36 DBS samples were submitted to sequencing, revealing the circulation of genotypes A (65.08%), D (4.8%), E (3.2%) and F (27%) with 100% of correspondence between serum and DBS. All sequenced samples displayed polymorphisms in HBsAg gene. An HIV-coinfected patient presented the rtM204V/I-rtL180M double resistance mutation in serum and DBS. In conclusion, DBS is an alternative to detect, quantify and characterize HBV DNA, being a possibility of increasing diagnosis in low-income settings, closing gaps in HBV control.
Collapse
|
11
|
Carty PG, McCarthy M, O'Neill SM, De Gascun CF, Harrington P, O'Neill M, Smith SM, Teljeur C, Ryan M. Laboratory-based testing for hepatitis C infection using dried blood spot samples: A systematic review and meta-analysis of diagnostic accuracy. Rev Med Virol 2021; 32:e2320. [PMID: 34957630 DOI: 10.1002/rmv.2320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 12/11/2021] [Accepted: 12/13/2021] [Indexed: 11/10/2022]
Abstract
The use of dried blood spot (DBS) samples can facilitate the implementation of reflex testing by circumventing the need for centrifugation and freezing of venous blood samples. This systematic review assessed the accuracy of using DBS samples to diagnose chronic hepatitis C virus (HCV) infection. A comprehensive search was undertaken to identify articles published up to July 2020 evaluating the diagnostic accuracy of anti-HCV, HCV-RNA and HCV core antigen tests using DBS. Screening, data extraction, quality appraisal and Grading of Recommendations, Assessment, Development and Evaluations certainty of the evidence assessment were performed independently by two reviewers. Meta-analysis, meta-regression and sensitivity analyses were conducted. The evidence demonstrates that laboratory-based anti-HCV and HCV-RNA tests using DBS samples have high diagnostic accuracy. All comparisons were between DBS and venous samples. For the detection of anti-HCV, sensitivity was 95% (95% CI: 92%-97%) and specificity was 99% ([95% CI: 98%-99%]; n = 25; I2 = 81%; moderate certainty). For the detection of HCV-RNA, the sensitivity was 95% (95% CI: 93%-97%) and specificity was 97% ([95% CI: 94%-98%]; n = 20; I2 = 52%; moderate certainty). The sensitivity of HCV core antigen tests was 86% (95% CI: 79%-91%) and specificity was 98% ([95% CI: 94%-99%]; n = 5; I2 = 37%; low certainty) compared with HCV-RNA (the gold standard for detecting chronic HCV). DBS samples could facilitate diagnosis of chronic HCV infection as the necessary sequential tests (anti-HCV and then HCV-RNA or HCV core antigen) can be undertaken using the same blood sample. This could reduce loss of patient follow-up and support international efforts towards HCV elimination in both high and low prevalence settings.
Collapse
Affiliation(s)
- Paul G Carty
- Faculty of Medicine & Health Sciences, RCSI University of Medicine and Health Sciences, Dublin, Ireland.,Health Information and Quality Authority, Dublin, Ireland
| | | | | | - Cillian F De Gascun
- National Virus Reference Laboratory, University College Dublin, Dublin, Ireland
| | | | | | - Susan M Smith
- Department of General Practice, Health Research Board Centre for Primary Care Research, Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Conor Teljeur
- Health Information and Quality Authority, Dublin, Ireland
| | - Mairin Ryan
- Health Information and Quality Authority, Dublin, Ireland.,Department of Pharmacology & Therapeutics, Trinity College Dublin, Trinity Health Sciences, St James's Hospital, Dublin, Ireland
| |
Collapse
|
12
|
Cook A, Faustini S, Williams L, Cunningham A, Drayson M, Shields A, Kay D, Taylor L, Plant T, Huissoon A, Wallis G, Beck S, Jossi S, Perez-Toledo M, Newby M, Allen J, Crispin M, Harding S, Richter A. Validation of a combined ELISA to detect IgG, IgA and IgM antibody responses to SARS-CoV-2 in mild or moderate non-hospitalised patients. J Immunol Methods 2021; 494:113046. [PMID: 33775672 PMCID: PMC7997147 DOI: 10.1016/j.jim.2021.113046] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 03/18/2021] [Accepted: 03/20/2021] [Indexed: 12/16/2022]
Abstract
BACKGROUND Frequently SARS-CoV-2 results in mild or moderate disease with potentially lower concentrations of antibodies compared to those that are hospitalised. Here, we validated an ELISA using SARS-CoV-2 trimeric spike glycoprotein, with targeted detection of IgG, IgA and IgM (IgGAM) using serum and dried blood spots (DBS) from adults with mild or moderate disease. METHODS Targeting the SARS-CoV-2 trimeric spike, a combined anti-IgG, IgA and IgM serology ELISA assay was developed using 62 PCR-confirmed non-hospitalised, mild or moderate COVID-19 samples, ≥14 days post symptom onset and 624 COVID-19 negative samples. The assay was validated using 73 PCR-confirmed non-hospitalised, mild or moderate COVID-19 samples, ≥14 days post symptom onset and 359 COVID-19 negative serum samples with an additional 81 DBSs. The assay was further validated in 226 PCR-confirmed non-hospitalised, mild or moderate COVID-19 samples, ≥14 days post symptom onset and 426 COVID-19 negative clinical samples. RESULTS A sensitivity and specificity of 98.6% (95% CI, 92.6-100.0), 98.3% (95% CI, 96.4-99.4), respectively, was observed following validation of the SARS-CoV-2 ELISA. No cross-reactivities with endemic coronaviruses or other human viruses were observed, and no change in results were recorded for interfering substances. The assay was stable at temperature extremes and components were stable for 15 days once opened. A matrix comparison showed DBS to correlate with serum results. Clinical validation of the assay reported a sensitivity of 94.7% (95% CI, 90.9-97.2%) and a specificity of 98.4% (95% CI, 96.6-99.3%). CONCLUSIONS The human anti-IgGAM SARS-CoV-2 ELISA provides accurate and sensitive detection of SARS-CoV-2 antibodies in non-hospitalised adults with mild or moderate disease. The use of dried blood spots makes the assay accessible to the wider community.
Collapse
Affiliation(s)
- A.M. Cook
- The Binding Site Group Ltd, 8 Calthorpe Road, Birmingham B15 1QT, UK
| | - S.E. Faustini
- Clinical Immunology Service, University of Birmingham College of Medical and Dental Sciences, Birmingham B15 2TT, UK
| | - L.J. Williams
- The Binding Site Group Ltd, 8 Calthorpe Road, Birmingham B15 1QT, UK,Corresponding author at: The Binding Site Group, 8 Calthorpe Road, Birmingham B15 1QT, UK
| | - A.F. Cunningham
- Institute of Immunology and Immunotherapy, University of Birmingham, Birmingham B15 2TT, UK
| | - M.T. Drayson
- Clinical Immunology Service, University of Birmingham College of Medical and Dental Sciences, Birmingham B15 2TT, UK
| | - A.M. Shields
- Clinical Immunology Service, University of Birmingham College of Medical and Dental Sciences, Birmingham B15 2TT, UK,University Hospitals Birmingham, NHS Foundation Trust, Birmingham B15 2GW, UK
| | - D. Kay
- The Binding Site Group Ltd, 8 Calthorpe Road, Birmingham B15 1QT, UK
| | - L. Taylor
- The Royal Wolverhampton NHS Trust, Wolverhampton Road, Wolverhampton, West Midlands WV10 0QP, UK
| | - T. Plant
- Clinical Immunology Service, University of Birmingham College of Medical and Dental Sciences, Birmingham B15 2TT, UK
| | - A. Huissoon
- Institute of Immunology and Immunotherapy, University of Birmingham, Birmingham B15 2TT, UK,University Hospitals Birmingham, NHS Foundation Trust, Birmingham B15 2GW, UK
| | - G. Wallis
- The Binding Site Group Ltd, 8 Calthorpe Road, Birmingham B15 1QT, UK
| | - S. Beck
- University Hospitals Birmingham, NHS Foundation Trust, Birmingham B15 2GW, UK
| | - S.E. Jossi
- Institute of Immunology and Immunotherapy, University of Birmingham, Birmingham B15 2TT, UK
| | - M. Perez-Toledo
- Institute of Immunology and Immunotherapy, University of Birmingham, Birmingham B15 2TT, UK
| | - M.L. Newby
- School of Biological Sciences, University of Southampton, Southampton SO17 1BJ, UK
| | - J.D. Allen
- School of Biological Sciences, University of Southampton, Southampton SO17 1BJ, UK
| | - M. Crispin
- School of Biological Sciences, University of Southampton, Southampton SO17 1BJ, UK
| | - S. Harding
- The Binding Site Group Ltd, 8 Calthorpe Road, Birmingham B15 1QT, UK
| | - A.G. Richter
- Clinical Immunology Service, University of Birmingham College of Medical and Dental Sciences, Birmingham B15 2TT, UK,University Hospitals Birmingham, NHS Foundation Trust, Birmingham B15 2GW, UK
| |
Collapse
|
13
|
Turgeon CT, Sanders KA, Rinaldo P, Granger D, Hilgart H, Matern D, Theel ES. Validation of a multiplex flow immunoassay for detection of IgG antibodies against SARS-CoV-2 in dried blood spots. PLoS One 2021; 16:e0252621. [PMID: 34048503 PMCID: PMC8162624 DOI: 10.1371/journal.pone.0252621] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Accepted: 05/18/2021] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Dried blood spots (DBS) are an established specimen type for clinical testing given their low cost, ease of collection and storage, and convenient shipping capabilities through the postal system. These attributes are complementary to the expansion of SARS-CoV-2 serologic testing, which may be used to inform community seroprevalence rates. METHODS The Luminex xMAP SARS-CoV-2 Multi-Antigen assay utilizes magnetic beads labeled with three viral antigens (nucleocapsid [NC], receptor binding domain [RBD], spike S1 subunit) to detect anti-viral IgG-class antibodies, and has Food and Drug Administration (FDA) Emergency Use Authorization (EUA) for use in serum and plasma. This assay was modified for use with DBS and validated against paired sera tested by one of two reference assays: the Roche Diagnostics Elecsys anti-SARS-CoV-2 ECLIA or the Euroimmun anti-SARS-CoV-2 IgG ELISA. RESULTS 159 paired DBS and serum specimens analyzed using the modified Luminex xMAP assay on DBS and the reference methods on serum showed an overall concordance of 96.9% (154/159). Use of multivariate pattern recognition software (CLIR) for post-analytical interpretation of the Luminex xMAP DBS assay results, instead of manufacturer provided interpretive thresholds, increased overall qualitative result concordance to 99.4% (158/159) between the modified Luminex xMAP DBS and reference results. CONCLUSIONS Use of DBS for detection of antibodies against SARS-CoV-2 provides comparable results to those obtained using serum. DBS concordance was improved with multivariate pattern recognition software (CLIR). We demonstrate that DBS are a reliable specimen type for SARS-CoV-2 antibody detection using the modified Luminex xMAP assay.
Collapse
Affiliation(s)
- Coleman T. Turgeon
- Divisions of Laboratory Genetics and Genomics and Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Karen A. Sanders
- Divisions of Laboratory Genetics and Genomics and Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Piero Rinaldo
- Divisions of Laboratory Genetics and Genomics and Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Dane Granger
- Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Heather Hilgart
- Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Dietrich Matern
- Divisions of Laboratory Genetics and Genomics and Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Elitza S. Theel
- Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, United States of America
| |
Collapse
|
14
|
Brinc D, Biondi MJ, Li D, Sun H, Capraru C, Smookler D, Zahoor MA, Casey J, Kulasingam V, Feld JJ. Evaluation of Dried Blood Spot Testing for SARS-CoV-2 Serology Using a Quantitative Commercial Assay. Viruses 2021; 13:962. [PMID: 34067361 PMCID: PMC8224688 DOI: 10.3390/v13060962] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 05/10/2021] [Accepted: 05/19/2021] [Indexed: 12/22/2022] Open
Abstract
Dried blood spots (DBS) are commonly used for serologic testing for viruses and provide an alternative collection method when phlebotomy and/or conventional laboratory testing are not readily available. DBS collection could be used to facilitate widespread testing for SARS-CoV-2 antibodies to document past infection, vaccination, and potentially immunity. We investigated the characteristics of Roche's Anti-SARS-CoV-2 (S) assay, a quantitative commercial assay for antibodies against the spike glycoprotein. Antibody levels were reduced relative to plasma following elution from DBS. Quantitative results from DBS samples were highly correlated with values from plasma (r2 = 0.98), allowing for extrapolation using DBS results to accurately estimate plasma antibody levels. High concordance between plasma and fingerpick DBS was observed in PCR-confirmed COVID-19 patients tested 90 days or more after the diagnosis (45/46 matched; 1/46 mismatched plasma vs. DBS). The assessment of antibody responses to SARS-CoV-2 using DBS may be feasible using a quantitative anti-S assay, although false negatives may rarely occur in those with very low antibody levels.
Collapse
Affiliation(s)
- Davor Brinc
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON M5S 1A8, Canada; (D.B.); (V.K.)
- Department of Clinical Biochemistry, University Health Network, Toronto, ON M5G 2C4, Canada;
| | - Mia J. Biondi
- Viral Hepatitis Care Network (VIRCAN) Study Group, Toronto Centre for Liver Disease, Toronto, ON M5G 2C, Canada; (M.J.B.); (C.C.); (D.S.); (M.A.Z.); (J.C.)
| | - Daniel Li
- Institute of Medical Science, University of Toronto, Toronto, ON M5S 1A8, Canada;
| | - Heng Sun
- Department of Clinical Biochemistry, University Health Network, Toronto, ON M5G 2C4, Canada;
| | - Camelia Capraru
- Viral Hepatitis Care Network (VIRCAN) Study Group, Toronto Centre for Liver Disease, Toronto, ON M5G 2C, Canada; (M.J.B.); (C.C.); (D.S.); (M.A.Z.); (J.C.)
| | - David Smookler
- Viral Hepatitis Care Network (VIRCAN) Study Group, Toronto Centre for Liver Disease, Toronto, ON M5G 2C, Canada; (M.J.B.); (C.C.); (D.S.); (M.A.Z.); (J.C.)
| | - Muhammad Atif Zahoor
- Viral Hepatitis Care Network (VIRCAN) Study Group, Toronto Centre for Liver Disease, Toronto, ON M5G 2C, Canada; (M.J.B.); (C.C.); (D.S.); (M.A.Z.); (J.C.)
| | - Julia Casey
- Viral Hepatitis Care Network (VIRCAN) Study Group, Toronto Centre for Liver Disease, Toronto, ON M5G 2C, Canada; (M.J.B.); (C.C.); (D.S.); (M.A.Z.); (J.C.)
| | - Vathany Kulasingam
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON M5S 1A8, Canada; (D.B.); (V.K.)
- Department of Clinical Biochemistry, University Health Network, Toronto, ON M5G 2C4, Canada;
| | - Jordan J. Feld
- Viral Hepatitis Care Network (VIRCAN) Study Group, Toronto Centre for Liver Disease, Toronto, ON M5G 2C, Canada; (M.J.B.); (C.C.); (D.S.); (M.A.Z.); (J.C.)
- Institute of Medical Science, University of Toronto, Toronto, ON M5S 1A8, Canada;
| |
Collapse
|
15
|
Anderson M, Holzmayer V, Vallari A, Taylor R, Moy J, Cloherty G. Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assays. J Clin Virol 2021; 141:104855. [PMID: 34144453 PMCID: PMC8111886 DOI: 10.1016/j.jcv.2021.104855] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 04/22/2021] [Accepted: 05/04/2021] [Indexed: 12/31/2022]
Abstract
Serologic testing for SARS-CoV-2 antibodies can be used to confirm diagnosis, estimate seroprevalence, screen convalescent plasma donors, and assess vaccine efficacy. Dried blood spot (DBS) samples have been used for serology testing of various diseases in resource-limited settings. We examined the use of DBS samples and capillary blood (fingerstick) plasma collected in Microtainer tubes for SARS-CoV-2 testing with the automated Abbott ARCHITECT™ SARS-CoV-2 IgG and IgM assays and use of venous whole blood with a prototype PANBIO™ rapid point-of-care lateral flow SARS-CoV-2 IgG assay. The ARCHITECT™ SARS-CoV-2 IgG assay was initially optimized for use with DBS, venous and capillary plasma, and venous whole blood collected from patients with symptoms and PCR-confirmed COVID-19 and negative asymptomatic controls. Linearity and reproducibility was confirmed with 3 contrived DBS samples, along with sample stability and signal recovery after 14 days. ARCHITECT™ SARS-CoV-2 IgG and IgM assay results showed high concordance between fingerstick DBS and venous DBS samples, and between fingerstick DBS and venous whole blood samples (n = 61). Fingerstick plasma collected in Microtainer tubes (n = 109) showed 100% concordant results (R2=0.997) with matched patient venous plasma on the ARCHITECT™ SARS-CoV-2 IgG assay. High concordance of assay results (92.9% positive, 100% negative) was also observed for the PANBIO™ SARS-CoV-2 IgG assay compared to the ARCHITECT™ SARS-CoV-2 IgG assay run with matched venous plasma (n = 61). Fingerstick DBS and plasma samples are easy and inexpensive to collect and, along with the use of rapid point-of-care testing platforms, will expand access to SARS-CoV-2 serology testing, particularly in resource-limited areas.
Collapse
Affiliation(s)
- Mark Anderson
- Abbott Laboratories, Abbott Diagnostics Division, 100 Abbott Park Road, Bldg. AP20, Abbott Park, IL 60064-3500, United States
| | - Vera Holzmayer
- Abbott Laboratories, Abbott Diagnostics Division, 100 Abbott Park Road, Bldg. AP20, Abbott Park, IL 60064-3500, United States
| | - Ana Vallari
- Abbott Laboratories, Abbott Diagnostics Division, 100 Abbott Park Road, Bldg. AP20, Abbott Park, IL 60064-3500, United States
| | - Russell Taylor
- Abbott Laboratories, Abbott Diagnostics Division, 100 Abbott Park Road, Bldg. AP20, Abbott Park, IL 60064-3500, United States
| | - James Moy
- Rush University Medical Center, Chicago, Illinois, United States
| | - Gavin Cloherty
- Abbott Laboratories, Abbott Diagnostics Division, 100 Abbott Park Road, Bldg. AP20, Abbott Park, IL 60064-3500, United States.
| |
Collapse
|
16
|
Transfusion-Transmitted Infections and associated risk factors at the Northern Zone Blood Transfusion Center in Tanzania: A study of blood donors between 2017 and 2019. PLoS One 2021; 16:e0249061. [PMID: 33760870 PMCID: PMC7990303 DOI: 10.1371/journal.pone.0249061] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2021] [Accepted: 03/10/2021] [Indexed: 12/03/2022] Open
Abstract
Background Blood transfusion saves many people every year that would otherwise have died. The present study aimed to provide an update and insightful information regarding prevalence of the common Transfusion-Transmitted Infections (TTIs) and associated factors among blood donors in Tanzania. Methods This was a cross-sectional study involving retrospectively collected data of blood donors from the Tanzania Northern Zone Blood Transfusion Center between 2017 and 2019. Descriptive statistics were performed to describe characteristics of the blood donors. Univariable and multivariable logistic regression analyses were performed to determine association between prevalence of TTIs and socio-demographic factors. P-value <0.05 was considered statistically significant. Results A total of 101, 616 blood donors were included in the present study of which 85,053(83.7%) were males while 16,563 (16.3%) were females. Of all participants, the majority 45,400 (44.7%) were aged between 18 and 25 years; 79,582 (78.3%) were voluntary non-remunerated donors while 22,034 (21.7%) were replacement donors. The vast majority of them 99,626 (98%) were first time blood donors while 1990 (2%) were multiple donors. The overall prevalence of TTIs was 10.1% (10,226 out of 101,616) of which the leading was HBV accounting for 5.1% (5,264 out of 101,616). Being a replacement donor was associated with all the four types of TTIs: HIV (AOR = 1.22, 95% CI = 1.10–1.35), HBV (AOR = 1.35, 95% CI = 1.27–1.44), HCV (AOR = 1.28, 95% CI = 1.12–1.46), and syphilis (AOR = 1.33, 95% CI = 1.20–1.48). Conclusions Our study has demonstrated that Tanzania has relatively high prevalence of TTIs compared to some countries in Sub-Saharan Africa. HBV infection seems to be the most common infection among blood donors and replacement blood donors are at a higher risk of harboring the commonest TTIs among blood donors.
Collapse
|
17
|
Amini F, Auma E, Hsia Y, Bilton S, Hall T, Ramkhelawon L, Heath PT, Le Doare K. Reliability of dried blood spot (DBS) cards in antibody measurement: A systematic review. PLoS One 2021; 16:e0248218. [PMID: 33720928 PMCID: PMC7959368 DOI: 10.1371/journal.pone.0248218] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Accepted: 02/23/2021] [Indexed: 02/06/2023] Open
Abstract
Background Increasingly, vaccine efficacy studies are being recommended in low-and-middle-income countries (LMIC), yet often facilities are unavailable to take and store infant blood samples correctly. Dried blood spots (DBS), are useful for collecting blood from infants for diagnostic purposes, especially in low-income settings, as the amount of blood required is miniscule and no refrigeration is required. Little is known about their utility for antibody studies in children. This systematic review aims to investigate the correlation of antibody concentrations against infectious diseases in DBS in comparison to serum or plasma samples that might inform their use in vaccine clinical trials. Methods and findings We searched MEDLINE, Embase and the Cochrane library for relevant studies between January 1990 to October 2020 with no language restriction, using PRISMA guidelines, investigating the correlation between antibody concentrations in DBS and serum or plasma samples, and the effect of storage temperature on DBS diagnostic performance. We included 40 studies in this systematic review. The antibody concentration in DBS and serum/plasma samples reported a good pooled correlation, (r2 = 0.86 (ranged 0.43 to 1.00)). Ten studies described a decline of antibody after 28 days at room temperature compared to optimal storage at -20°C, where antibodies were stable for up to 200 days. There were only five studies of anti-bacterial antibodies. Conclusions There is a good correlation between antibody concentrations in DBS and serum/plasma samples, supporting the wider use of DBS in vaccine and sero-epidemiological studies, but there is limited data on anti-bacterial antibodies. The correct storage of DBS is critical and may be a consideration for longer term storage.
Collapse
Affiliation(s)
- Fahimah Amini
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
- * E-mail:
| | - Erick Auma
- Department of Biology, University of Lyon, Université Claude Bernard Lyon, ENS de Lyon, CNRS, UMR, Lyon, France
| | - Yingfen Hsia
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
- School of Pharmacy, Queen’s University Belfast, Belfast, United Kingdom
| | - Sam Bilton
- St Georges University Hospitals NHS Foundation Trust, Tooting, London, United Kingdom
| | - Tom Hall
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
| | - Laxmee Ramkhelawon
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
| | - Paul T. Heath
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
- St Georges University Hospitals NHS Foundation Trust, Tooting, London, United Kingdom
| | - Kirsty Le Doare
- Paediatric Infectious Disease Research Group, Institute for Infection and Immunity, St. George’s University of London, London, United Kingdom
- St Georges University Hospitals NHS Foundation Trust, Tooting, London, United Kingdom
- Pathogen Immunology Group, Public Health England, Porton Down, United Kingdom
| |
Collapse
|
18
|
Martínez-Campreciós J, Rando-Segura A, Buti M, Rodrigo-Velásquez F, Riveiro-Barciela M, Barreira-Díaz A, Álvarez-López P, Salmerón P, Palom A, Tabernero D, Palomo N, Nindia A, Barbosa G, López E, Ferreira V, Saiago N, Kuchta A, Ferrer-Costa R, Esteban R, Molina I, Rodríguez-Frías F. Reflex viral load testing in dried blood spots generated by plasma separation card allows the screening and diagnosis of chronic viral hepatitis. J Virol Methods 2021; 289:114039. [PMID: 33338545 DOI: 10.1016/j.jviromet.2020.114039] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 12/03/2020] [Accepted: 12/06/2020] [Indexed: 02/07/2023]
Abstract
Dried blood spots (DBS) have been proposed as an alternative diagnostic technique for chronic viral hepatitis. The aim of this observational study was to correlate serologic HBV, HCV, and HDV status and reflex the respective viral load testing by PSC-DBS samples from capillary blood vs conventional plasma samples in patients with chronic viral hepatitis. Besides, we apply these tests in a prospective study for chronic viral hepatitis diagnosis in a rural region of sub-Saharan Africa. In total, 124 HBsAg-positive patients, 75 anti-HCV positive, 2 with HBV-HCV coinfection, and 13 anti-HDV positive were included. PSC-DBS sensitivity/specificity was 98.4 %/96.2 % for HBsAg detection, 98.7 %/100 % for anti-HCV, and 84.6 %/100 % for anti-HDV. HCV-RNA was quantified in all viremic patients using DBS. Only 42 of 78 (53.8 %) samples with HBV-DNA viremia were quantifiable by DBS. Sensitivity increased to 95.7 % in patients with HBV-DNA levels >2000 IU/mL. There was a high correlation between DBS and venous blood. The prevalence of HBsAg among the 93 individuals tested in Angola was 11 %, and 60 % of cases had detectable HBV-DNA viremia. As a conclusion, PSC-DBS is useful for chronic viral hepatitis screening and reflex molecular diagnosis showing globally high sensitivities and correlation with conventional blood samples.
Collapse
Affiliation(s)
- Joan Martínez-Campreciós
- Liver Unit, Internal Medicine Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Vall d'Hebron Barcelona Hospital Campus, Passeig Vall d'Hebron 119-129, 080335 Barcelona, Spain; Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain
| | - Ariadna Rando-Segura
- Vall d'Hebron Barcelona Hospital Campus, Passeig Vall d'Hebron 119-129, 080335 Barcelona, Spain; Department of Microbiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain
| | - María Buti
- Liver Unit, Internal Medicine Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Vall d'Hebron Barcelona Hospital Campus, Passeig Vall d'Hebron 119-129, 080335 Barcelona, Spain; CIBERehd, Instituto Carlos II, Spain.
| | - Fernando Rodrigo-Velásquez
- Vall d'Hebron Barcelona Hospital Campus, Passeig Vall d'Hebron 119-129, 080335 Barcelona, Spain; Department of Microbiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain
| | - Mar Riveiro-Barciela
- Liver Unit, Internal Medicine Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Vall d'Hebron Barcelona Hospital Campus, Passeig Vall d'Hebron 119-129, 080335 Barcelona, Spain; CIBERehd, Instituto Carlos II, Spain
| | - Ana Barreira-Díaz
- Liver Unit, Internal Medicine Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Vall d'Hebron Barcelona Hospital Campus, Passeig Vall d'Hebron 119-129, 080335 Barcelona, Spain
| | - Patricia Álvarez-López
- Liver Unit, Internal Medicine Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Vall d'Hebron Barcelona Hospital Campus, Passeig Vall d'Hebron 119-129, 080335 Barcelona, Spain
| | - Paula Salmerón
- Vall d'Hebron Barcelona Hospital Campus, Passeig Vall d'Hebron 119-129, 080335 Barcelona, Spain; Department of Microbiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain
| | - Adriana Palom
- Liver Unit, Internal Medicine Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Vall d'Hebron Barcelona Hospital Campus, Passeig Vall d'Hebron 119-129, 080335 Barcelona, Spain
| | - David Tabernero
- CIBERehd, Instituto Carlos II, Spain; Liver Pathology Unit, Biochemistry and Microbiology Departments, Hospital Universitari Vall d'Hebron, Barcelona, Spain
| | - Nieves Palomo
- Liver Unit, Internal Medicine Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Vall d'Hebron Barcelona Hospital Campus, Passeig Vall d'Hebron 119-129, 080335 Barcelona, Spain
| | | | | | - Eva López
- Hospital Nossa Senhora da Paz, Cubal, Angola
| | - Vicelma Ferreira
- Hospital General de Benguela, Universidade Katyavla Bwila, Benguela, Angola
| | - Nelsa Saiago
- Hospital General de Benguela, Universidade Katyavla Bwila, Benguela, Angola
| | | | - Roser Ferrer-Costa
- Biochemistry Department, Clinical Laboratories Hospital Universitari Vall d'Hebron, Spain
| | - Rafael Esteban
- Liver Unit, Internal Medicine Department, Hospital Universitari Vall d'Hebron, Barcelona, Spain; Vall d'Hebron Barcelona Hospital Campus, Passeig Vall d'Hebron 119-129, 080335 Barcelona, Spain; CIBERehd, Instituto Carlos II, Spain
| | - Israel Molina
- Infectious Diseases Department, Hospital Universitari Vall d'Hebron, PROSICS Barcelona, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Francisco Rodríguez-Frías
- CIBERehd, Instituto Carlos II, Spain; Biochemistry Department, Clinical Laboratories Hospital Universitari Vall d'Hebron, Spain; Liver Pathology Unit, Biochemistry and Microbiology Departments, Hospital Universitari Vall d'Hebron, Barcelona, Spain
| |
Collapse
|
19
|
Prabdial‐Sing N, Gaelejwe L, Makhathini L, Thaver J, Manamela MJ, Malfeld S, Spearman CW, Sonderup M, Scheibe A, Young K, Hausler H, Puren AJ. The performance of hepatitis C virus (HCV) antibody point-of-care tests on oral fluid or whole blood and dried blood spot testing for HCV serology and viral load among individuals at higher risk for HCV in South Africa. Health Sci Rep 2021; 4:e229. [PMID: 33614978 PMCID: PMC7876859 DOI: 10.1002/hsr2.229] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 11/10/2020] [Accepted: 12/04/2020] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND AND AIMS To enhance screening and diagnosis in those at-risk of hepatitis C virus (HCV), efficient and improved sampling and testing is required. We investigated the performance of point-of-care (POC) tests and dried blood spots (DBS) for HCV antibody and HCV RNA quantification in individuals at higher risk for HCV (people who use and inject drugs, sex workers and men who have sex with men) in seven South African cities. METHODS Samples were screened on the OraQuick HCV POC test (471 whole blood and 218 oral fluid); 218 whole blood and DBS paired samples were evaluated on the ARCHITECT HCV antibody (Abbott) and HCV viral load (COBAS Ampliprep/COBAS TaqMan version 2) assays. For HCV RNA quantification, 107 dB were analyzed with and without normalization coefficients. RESULTS POC on either whole blood or oral fluid showed an overall sensitivity of 98.5% (95% CI 97.4-99.5), specificity of 98.2% (95% CI 98.8-100) and accuracy of 98.4% (95% CI 96.5-99.3). On the antibody immunoassay, DBS showed a sensitivity of 96.0% (95% CI 93.4-98.6), specificity of 97% (95% CI 94.8-99.3) and accuracy of 96.3% (95% CI 93.8-98.8). A strong correlation (R 2 = 0.90) between viral load measurements for DBS and plasma samples was observed. After normalization, DBS viral load results showed an improved bias from 0.5 to 0.16 log10 IU/mL. CONCLUSION The POC test performed sufficiently well to be used for HCV screening in at-risk populations. DBS for diagnosis and quantification was accurate and should be considered as an alternative sample to test. POC and DBS can help scale up hepatitis services in the country, in light of our elimination goals.
Collapse
Affiliation(s)
- Nishi Prabdial‐Sing
- Centre for Vaccines and ImmunologyNational Institute for Communicable DiseasesJohannesburgSouth Africa
- Faculty of Health SciencesUniversity of WitwatersrandJohannesburgSouth Africa
| | - Lucinda Gaelejwe
- Centre for Vaccines and ImmunologyNational Institute for Communicable DiseasesJohannesburgSouth Africa
- Faculty of Health SciencesUniversity of WitwatersrandJohannesburgSouth Africa
| | - Lillian Makhathini
- Centre for Vaccines and ImmunologyNational Institute for Communicable DiseasesJohannesburgSouth Africa
| | - Jayendrie Thaver
- Centre for Vaccines and ImmunologyNational Institute for Communicable DiseasesJohannesburgSouth Africa
| | - Morubula Jack Manamela
- Centre for Vaccines and ImmunologyNational Institute for Communicable DiseasesJohannesburgSouth Africa
| | - Susan Malfeld
- Centre for Vaccines and ImmunologyNational Institute for Communicable DiseasesJohannesburgSouth Africa
| | - C. Wendy Spearman
- Division of Hepatology, Department of Medicine, Faculty of Health SciencesUniversity of Cape TownCape TownSouth Africa
| | - Mark Sonderup
- Division of Hepatology, Department of Medicine, Faculty of Health SciencesUniversity of Cape TownCape TownSouth Africa
| | - Andrew Scheibe
- TB HIV CareCape TownSouth Africa
- Department of Family MedicineUniversity of PretoriaPretoriaSouth Africa
| | | | | | - Adrian J. Puren
- Centre for Vaccines and ImmunologyNational Institute for Communicable DiseasesJohannesburgSouth Africa
- Faculty of Health SciencesUniversity of WitwatersrandJohannesburgSouth Africa
| |
Collapse
|
20
|
Carpentieri D, Colvard A, Petersen J, Marsh W, David-Dirgo V, Huentelman M, Pirrotte P, Sivakumaran TA. Mind the Quality Gap When Banking on Dry Blood Spots. Biopreserv Biobank 2021; 19:136-142. [PMID: 33567235 DOI: 10.1089/bio.2020.0131] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
Dry blood spots (DBS) offer many advantages over other blood banking protocols due to the reduction of time and equipment needed for collection and the ease of processing, storage, and shipment. In addition, the sample size makes it a very attractive method when considering the banking of small pediatric samples. On that note, the Centers for Disease Control and Prevention (CDC) preanalytical standards for DBS are commonly used in the worldwide mass spectrometry-based inborn errors of metabolism screening programs. However, these guidelines may not apply for analytes and protocols not included in these programs. In fact, the availability of leftover samples and the ongoing interest in protocols outside this scenario are providing us with new DBS biobanking insights. Herein, we review the literature for indicators that should be considered in the design of prospective fit for purpose DBS biobanks, especially for those focused mostly on pediatric and OMIC platforms.
Collapse
Affiliation(s)
- David Carpentieri
- Department of Pathology and Laboratory Medicine, Clinical Genomics, Phoenix Children's Hospital, Phoenix, Arizona, USA
| | - Amber Colvard
- Department of Pathology, Clinical Genomics, Phoenix Children's Hospital, Phoenix, Arizona, USA
| | - Jackie Petersen
- Department of Pathology, Clinical Genomics, Phoenix Children's Hospital, Phoenix, Arizona, USA
| | - William Marsh
- Department of Biorepository, Mayo Clinic, Phoenix, Arizona, USA
| | - Victoria David-Dirgo
- Collaborative Center for Translational Mass Spectrometry, The Translational Genomics Research Institute, Phoenix, Arizona, USA
| | - Matt Huentelman
- Neurogenomics Division, The Translational Genomics Research Institute, Phoenix, Arizona, USA
| | - Patrick Pirrotte
- Collaborative Center for Translational Mass Spectrometry, The Translational Genomics Research Institute, Phoenix, Arizona, USA
| | - T A Sivakumaran
- Department of Pathology, Clinical Genomics, Phoenix Children's Hospital, Phoenix, Arizona, USA
| |
Collapse
|
21
|
Ma J, He L, Chen K, Wang Y, Ren Y, Xing W, Jiang Y. Comparative study on anti-HCV testing using plasma, dried plasma spots (DPS), and dried blood spots (DBS). BIOSAFETY AND HEALTH 2021. [DOI: 10.1016/j.bsheal.2020.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
22
|
Dried Blood Spot in Laboratory: Directions and Prospects. Diagnostics (Basel) 2020; 10:diagnostics10040248. [PMID: 32340321 PMCID: PMC7235996 DOI: 10.3390/diagnostics10040248] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 04/16/2020] [Accepted: 04/21/2020] [Indexed: 12/14/2022] Open
Abstract
Over the past few years, dried blood spot (DBS) technology has become a convenient tool in both qualitative and quantitative biological analysis. DBS technology consists of a membrane carrier (MC) on the surface of which a biomaterial sample becomes absorbed. Modern analytical, immunological or genomic methods can be employed for analysis after drying the sample. DBS has been described as the most appropriate method for biomaterial sampling due to specific associated inherent advantages, including the small volumes of biomaterials required, the absence of a need for special conditions for samples’ storage and transportation, improved stability of analytes and reduced risk of infection resulting from contaminated samples. This review illustrates information on the current state of DBS technology, which can be useful and helpful for biomedical researchers. The prospects of using this technology to assess the metabolomic profile, assessment, diagnosis of communicable diseases are demonstrated.
Collapse
|
23
|
Ma J, Ren Y, He L, He X, Xing W, Jiang Y. An efficient method for simultaneously screening for HIV, syphilis, and HCV based on one dried blood spot sample. Antiviral Res 2020; 181:104775. [PMID: 32246944 DOI: 10.1016/j.antiviral.2020.104775] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 02/23/2020] [Accepted: 03/13/2020] [Indexed: 12/29/2022]
Abstract
OBJECTIVE The aim of this study was to optimize the parameters of a dried blood spot (DBS)-based ELISA method to simultaneously screen for anti-HIV, anti-hepatitis C virus (HCV) and anti-treponema pallidum (TP) antibodies, and investigate the assay performance. METHODS Experiments were performed to establish optimized parameters for a DBS-based ELISA method to simultaneously screen for anti-HIV, anti-HCV, and anti-TP antibodies. Then, 429 paired plasma and DBS samples were collected to evaluate the performance of the assay with optimized parameters. Plasma test results were used as the reference standard. RESULTS The optimized assay conditions were: blood volume, 70-100 μL; DBS size, whole spot; eluent volume, 500 μL; eluent, PBS with 1‰ Tween20; elution time, 4 h; elution temperature, room temperature. The overall prevalence of HIV, HCV, and TP was 6.06% (95% confidence interval [CI]: 4.07-8.87%), 27.74% (95% CI: 23.60-32.28%), and 14.92% (95% CI: 11.75-18.73%). The clinical sensitivity of the assay for anti-HIV, anti-HCV, and anti-TP antibodies was 88.46%, 98.32%, and 92.19%, respectively. The assay was 100% specificity for each analyte. The assay positive predictive value for each analyte was 100%, and the negative predictive values were >98%. Of the 429 samples, 9 DBS results were different than the plasma results; in these samples the plasma signal-to-cutoff rations were low (range, 1.40-7.81). CONCLUSION The DBS-based ELISA method demonstrated good performance for simultaneously screening for anti-HIV, anti-HCV, and anti-TP antibodies. DBS samples are a promising method to screen for HIV, HCV, and TP infections. IMPORTANCE DBS samples are a promising alternative to plasma samples, with the advantages of good sample stability, smaller blood volume, simpler storage, and easier transport. DBS sample testing is used for the diagnosis of a wide variety of pathogens, including HIV, hepatitis B virus (HBV), and hepatitis C virus (HCV). The performance of DBS samples for the serological diagnosis of HIV, HCV, and Treponema pallidum (TP) has been demonstrated to be good in many studies, and therefore DBS is regarded as an ideal choice to screen for HIV, HCV, and TP infections, especially in difficult-access or resource-limited settings. There is no generally accepted procedure for sample collection and processing of DBS samples and there are few studies on simultaneous detection of anti-HIV, anti-HCV and anti-TP using a single DBS.
Collapse
Affiliation(s)
- Jieqiong Ma
- National HIV/HCV Reference Laboratory, National Center for AIDS/STD Control and Prevention, China CDC, Beijing, China
| | - Yanan Ren
- National HIV/HCV Reference Laboratory, National Center for AIDS/STD Control and Prevention, China CDC, Beijing, China
| | - Lin He
- National HIV/HCV Reference Laboratory, National Center for AIDS/STD Control and Prevention, China CDC, Beijing, China
| | - Xiaoxia He
- National HIV/HCV Reference Laboratory, National Center for AIDS/STD Control and Prevention, China CDC, Beijing, China
| | - Wenge Xing
- National HIV/HCV Reference Laboratory, National Center for AIDS/STD Control and Prevention, China CDC, Beijing, China
| | - Yan Jiang
- National HIV/HCV Reference Laboratory, National Center for AIDS/STD Control and Prevention, China CDC, Beijing, China.
| |
Collapse
|
24
|
Cruz HM, de Paula VS, Cruz JCM, do Ó KMR, Milagres FAP, Bastos FI, Mota JCD, Cruz MS, Andrade TMD, Pollo-Flores P, Leal E, Motta-Castro ARC, Ivantes CAP, Bezerra CS, Barbosa JR, da Cruz JNM, Lewis-Ximenez LL, Villar LM. Evaluation of accuracy of hepatitis B virus antigen and antibody detection and relationship between epidemiological factors using dried blood spot. J Virol Methods 2019; 277:113798. [PMID: 31837375 DOI: 10.1016/j.jviromet.2019.113798] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Revised: 10/15/2019] [Accepted: 12/10/2019] [Indexed: 02/07/2023]
Abstract
Dried blood spots (DBS) testing might increase the access for Hepatitis B virus (HBV) diagnosis, but little is known about the performance of these assays in real life conditions. This study aims to evaluate the diagnostic accuracy of HBsAg, anti-HBc and anti-HBs detection in DBS in clinical settings and field studies and to evaluate demographic and risk behaviour according the presence of HBsAg and anti-HBc. Paired sera and DBS samples were obtained from 2309 individuals from 3 groups, defined as follows: G1: clinical setting (n = 5-19), G2: general population (n = 1305) and G3: vulnerable individuals that could be more exposed to blood contact (n = 485). Sera and DBS were tested using commercial enzyme immunoassay (EIA), with some modifications added. Using DBS samples, the specificity values were above 90 % for HBsAg and anti-HBc in all groups and for anti-HBs range from 58.6%-85%. HBsAg testing had the best performance in GI (sensitivity = 84.4 %) and among those samples that the paired serum also presented anti-HBc marker (sensitivity = 91.6 %). High sensitivity of anti-HBc testing in DBS samples was observed in GI (80.8 %) and among HBV active cases (HBsAg+/anti-HBc+) (98.4 %). Testing of anti-HBs in DBS showed the highest sensitivity in GIII (65.5 %), in previous HBV exposed and cured individuals and when serum titers were above 100 IU/mL (86.7 %). DBS samples could be used for screening and prevalence studies for HBsAg and anti-HBc, particularly in clinical settings and among HBV active cases in field studies.
Collapse
Affiliation(s)
- Helena Medina Cruz
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Rio de Janeiro, Brazil
| | | | | | | | | | - Francisco Inácio Bastos
- Institute of Communication and Scientific Information & Technology for Health, Oswaldo Cruz Foundation, Rio de Janeiro, Brazil
| | - Jurema Corrêa da Mota
- Institute of Communication and Scientific Information & Technology for Health, Oswaldo Cruz Foundation, Rio de Janeiro, Brazil
| | - Marcelo Santos Cruz
- Institute of Psychiatry, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | | | - Priscila Pollo-Flores
- Antonio Pedro University Hospital, Federal Fluminense University, Rio de Janeiro, Brazil
| | - Erotildes Leal
- Federal University of Rio de Janeiro, Faculty of Medicine, Rio de Janeiro, Brazil
| | | | | | - Cristianne Sousa Bezerra
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Rio de Janeiro, Brazil; Instituto Federal de Ciencia e Tecnologia do Ceará, Brazil
| | - Jakeline Ribeiro Barbosa
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Rio de Janeiro, Brazil; FIOCRUZ, Brasilia, Brazil
| | | | | | - Livia Melo Villar
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Rio de Janeiro, Brazil.
| |
Collapse
|
25
|
Parr JB, Lodge EK, Holzmayer V, Pepin J, Frost EH, Fried MW, McGivern DR, Lemon SM, Keeler C, Emch M, Mwandagalirwa K, Tshefu A, Fwamba F, Muwonga J, Meshnick SR, Cloherty G. An Efficient, Large-Scale Survey of Hepatitis C Viremia in the Democratic Republic of the Congo Using Dried Blood Spots. Clin Infect Dis 2019; 66:254-260. [PMID: 29048459 DOI: 10.1093/cid/cix771] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2017] [Accepted: 08/24/2017] [Indexed: 02/07/2023] Open
Abstract
Background Efficient viral load testing is needed for hepatitis C (HCV) surveillance and diagnosis. HCV viral load testing using dried blood spots (DBSs), made with a single drop of finger-prick whole blood on filter paper, is a promising alternative to traditional serum- or plasma-based approaches. Methods We adapted the Abbott Molecular m2000 instrument for high-throughput HCV viremia testing using DBSs with simple specimen processing and applied these methods to estimate the national burden of infection in the Democratic Republic of the Congo (DRC). We tested DBSs collected during the 2013-2014 DRC Demographic and Health Survey, including 1309 adults ≥40 years of age. HCV-positive samples underwent targeted sequencing, genotyping, and phylogenetic analyses. Results This high-throughput screening approach reliably identified HCV RNA extracted from DBSs prepared using whole blood, with a 95% limit of detection of 1196 (95% confidence interval [CI], 866-2280) IU/mL for individual 6-mm punches and 494 (95% CI, 372-1228) IU/mL for larger 12-mm punches. Fifteen infections were identified among samples from the DRC Demographic and Health Survey; the weighted country-wide prevalence of HCV viremia was 0.9% (95% CI, 0.3%-1.6%) among adults ≥40 years of age and 0.7% (95% CI, .6%-.8%) among human immunodeficiency virus-infected subjects. All successfully genotyped cases were due to genotype 4 infection. Conclusions DBS-based HCV testing represents a useful tool for the diagnosis and surveillance of HCV viremia and can easily be incorporated into specimen referral systems. Among adults ≥40 years of age in the DRC, 100000-200000 may have active infection and be eligible for treatment.
Collapse
Affiliation(s)
- Jonathan B Parr
- Division of Infectious Diseases, Department of Medicine, University of North Carolina, Chapel Hill
| | - Evans K Lodge
- School of Medicine, University of North Carolina, Chapel Hill
| | | | | | | | - Michael W Fried
- Division of Gastroenterology, Department of Medicine, University of North Carolina, Chapel Hill
| | - David R McGivern
- Division of Infectious Diseases, Department of Medicine, University of North Carolina, Chapel Hill
| | - Stanley M Lemon
- Division of Infectious Diseases, Department of Medicine, University of North Carolina, Chapel Hill
| | - Corinna Keeler
- Department of Geography, University of North Carolina, Chapel Hill
| | - Michael Emch
- Department of Geography, University of North Carolina, Chapel Hill.,Gillings School of Global Public Health, Department of Epidemiology, University of North Carolina, Chapel Hill
| | - Kashamuka Mwandagalirwa
- Gillings School of Global Public Health, Department of Epidemiology, University of North Carolina, Chapel Hill.,Kinshasa School of Public Health, Kinshasa, Democratic Republic of Congo
| | - Antoinette Tshefu
- Kinshasa School of Public Health, Kinshasa, Democratic Republic of Congo
| | - Franck Fwamba
- National AIDS Control Program, Kinshasa, Democratic Republic of Congo
| | - Jérémie Muwonga
- National AIDS Control Program, Kinshasa, Democratic Republic of Congo
| | - Steven R Meshnick
- Gillings School of Global Public Health, Department of Epidemiology, University of North Carolina, Chapel Hill
| | | |
Collapse
|
26
|
Villar LM, Cruz HM, Deodato RM, Miguel JC, da Silva EF, Flores GL, Lewis-Ximenez LL. Usefulness of automated assays for detecting hepatitis B and C markers in dried blood spot samples. BMC Res Notes 2019; 12:523. [PMID: 31429797 PMCID: PMC6700985 DOI: 10.1186/s13104-019-4547-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Accepted: 08/07/2019] [Indexed: 12/28/2022] Open
Abstract
Objective Dried blood spots (DBSs) can be used as an alternative to serum samples because they are easily collected and can be transported without refrigeration to reference laboratories for diagnosis. The present study was performed to evaluate the utility of electrochemiluminescence immunoassay “ECLIA” for anti-HCV, HBsAg and anti-HBc detection from DBS samples. Results Anti-HCV was detected in 103 DBS samples from 108 paired, positive serum and undetected in 364 DBS samples from 366 paired, negative specimens, giving a sensitivity of 95.4% and a specificity of 99.4%. HBsAg was detected in 67 DBS samples out of 71 positive, paired serum and was undetected among 295 DBS samples from 298 paired, negative specimens, giving a sensitivity and specificity of 94.4% and 99%, respectively. Anti-HBc was detected in 160 DBS samples from 185 paired, positive serum specimens and undetected in 349 DBS samples from 357 paired, negative serum specimens, giving a sensitivity of 86.5% and a specificity of 97.8%. Overall, the Kappa index indicated a high agreement between results obtained for the serum and DBS samples (k: 0.95, 0.93 and 0.86 for anti-HCV, HBsAg, anti-HBc, respectively). In conclusion, the ECLIA test could be used for detecting hepatitis B and C markers in DBS.
Collapse
Affiliation(s)
- Livia Melo Villar
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, FIOCRUZ, Hélio and Peggy Pereira Pavilion - Ground Floor - Office B09, FIOCRUZ Av. Brasil, 4365 - Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil.
| | - Helena Medina Cruz
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, FIOCRUZ, Hélio and Peggy Pereira Pavilion - Ground Floor - Office B09, FIOCRUZ Av. Brasil, 4365 - Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil
| | - Raissa Martins Deodato
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, FIOCRUZ, Hélio and Peggy Pereira Pavilion - Ground Floor - Office B09, FIOCRUZ Av. Brasil, 4365 - Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil
| | - Juliana Custódio Miguel
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, FIOCRUZ, Hélio and Peggy Pereira Pavilion - Ground Floor - Office B09, FIOCRUZ Av. Brasil, 4365 - Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil
| | - Elisangela Ferreira da Silva
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, FIOCRUZ, Hélio and Peggy Pereira Pavilion - Ground Floor - Office B09, FIOCRUZ Av. Brasil, 4365 - Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil
| | - Geane Lopes Flores
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, FIOCRUZ, Hélio and Peggy Pereira Pavilion - Ground Floor - Office B09, FIOCRUZ Av. Brasil, 4365 - Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil
| | - Lia Laura Lewis-Ximenez
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, FIOCRUZ, Hélio and Peggy Pereira Pavilion - Ground Floor - Office B09, FIOCRUZ Av. Brasil, 4365 - Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil
| |
Collapse
|
27
|
de Mendoza C, Bautista JM, Pérez-Benavente S, Kwawu R, Fobil J, Soriano V, Díez A. Screening for retroviruses and hepatitis viruses using dried blood spots reveals a high prevalence of occult hepatitis B in Ghana. Ther Adv Infect Dis 2019; 6:2049936119851464. [PMID: 31205689 PMCID: PMC6535694 DOI: 10.1177/2049936119851464] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Accepted: 04/12/2019] [Indexed: 12/17/2022] Open
Abstract
Background: Recent advances in antiviral therapy show potential for a cure and/or control of most human infections caused by hepatitis viruses and retroviruses. However, medical success is largely dependent on the identification of the large number of people unaware of these infections, especially in developing countries. Dried blood spots (DBS) have been demonstrated to be a good tool for collecting, storing and transporting clinical specimens from rural areas and limited-resource settings to laboratory facilities, where viral infections can be more reliably diagnosed. Methods: The seroprevalence and virological characterization of hepatitis B virus (HBV) and hepatitis C virus (HCV), as well as human retroviruses (HIV-1, HIV-2, human T-cell leukaemia virus type 1 [HTLV-1] and human T-cell leukaemia virus type 2 [HTLV-2]), were investigated in clinical specimens collected from DBS in Ghana. Results: A total of 305 consecutive DBS were collected. A high prevalence of chronic HBV (8.5%) and occult hepatitis B (14.2%) was found, whereas rates were lower for HIV-1, HTLV-1 and HCV (3.2%, 1.3% and 0.6%, respectively). HIV-2 and HTLV-2 were absent. CRF02_AG was the predominant HIV-1 subtype, whereas genotype E was the most frequent HBV variant. Conclusions: DBS are helpful in the diagnosis and virological characterization of hepatitis and retrovirus infections in resource-limited settings. The high rate of hepatitis B in Ghana, either overt or occult, is noteworthy and confirms recent findings from other sub-Saharan countries. This should encourage close clinical follow up and antiviral treatment assessment in this population, as well as universal HBV vaccine campaigns.
Collapse
Affiliation(s)
- Carmen de Mendoza
- Department of Biochemistry and Molecular Biology, Complutense University of Madrid, Faculty of Veterinary Sciences Avda. Puerta de Hierro, s/n. Ciudad Universitaria 28040 - MADRID-Spain
| | - José M Bautista
- Research Institute Hospital 12 de Octubre, Madrid, Spain, and Department of Biochemistry and Molecular Biology, Complutense University, Madrid, Spain
| | | | - Roger Kwawu
- Our Lady of Grace Hospital, Breman-Asikuma, Ghana
| | - Julius Fobil
- School of Public Health, University of Ghana, Accra, Ghana
| | | | - Amalia Díez
- Research Institute Hospital 12 de Octubre, Madrid, Spain, and Department of Biochemistry and Molecular Biology, Complutense University, Madrid, Spain
| |
Collapse
|
28
|
Vázquez-Morón S, Ardizone Jiménez B, Jiménez-Sousa MA, Bellón JM, Ryan P, Resino S. Evaluation of the diagnostic accuracy of laboratory-based screening for hepatitis C in dried blood spot samples: A systematic review and meta-analysis. Sci Rep 2019; 9:7316. [PMID: 31086259 PMCID: PMC6514168 DOI: 10.1038/s41598-019-41139-8] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Accepted: 02/27/2019] [Indexed: 12/25/2022] Open
Abstract
The dried blood spot (DBS) is increasingly used for the hepatitis C virus (HCV) screening. Our objective was to perform a meta-analysis of the methodology for HCV screening in DBS samples, particularly in the type of diagnostic assay used. We performed a meta-analysis of all eligible studies published to date (March 2018). The literature search revealed 26 studies: 21 for detection of anti-HCV antibodies and 10 for detection of HCV-RNA. Statistical analyses were performed using Meta-DiSc and STATA (MIDAS module). For detection of HCV antibodies, pooled diagnostic accuracy measures were as follows: sensitivity 96.1%, specificity 99.2%, positive likelihood ratio (PLR) 105, negative likelihood ratio (NLR) 0.04, diagnostic odds ratio (DOR) 2692.9, and summary receiver operating characteristic (SROC) 0.997 ± 0.001. For detection of HCV-RNA, the pooled diagnostic accuracy measures were as follows: sensitivity 97.8%, specificity 99.2%, PLR 44.8, NLR 0.04, DOR 1966.9, and SROC 0.996 ± 0.013. Similar values of pooled diagnostic accuracy measures were found according to the type of anti-HCV antibody detection assay (enzyme-linked immunosorbent assay, rapid diagnostic test, and chemiluminescence assays) and HCV-RNA detection assay (real-time polymerase chain reaction and transcription-mediated amplification). The analysis of external validity showed a high negative predicted value (NPV) for both approaches, but a low positive predicted value (PPV) when prevalence was < 10%, particularly in HCV-RNA tests. Finally, this meta-analysis is subject to limitations, especially publication bias and significant heterogeneity between studies. In conclusion, HCV screening in DBS samples has an outstanding diagnostic performance, with no relevant differences between the techniques used. However, external validity may be limited when the HCV prevalence is low.
Collapse
Affiliation(s)
- Sonia Vázquez-Morón
- Unidad de Infección Viral e Inmunidad. Centro Nacional de Microbiología - Instituto de Salud Carlos III, Majadahonda, Spain
| | - Beatriz Ardizone Jiménez
- Unidad de Infección Viral e Inmunidad. Centro Nacional de Microbiología - Instituto de Salud Carlos III, Majadahonda, Spain
| | - María A Jiménez-Sousa
- Unidad de Infección Viral e Inmunidad. Centro Nacional de Microbiología - Instituto de Salud Carlos III, Majadahonda, Spain
| | - José M Bellón
- Hospital General Universitario Gregorio Marañón, Madrid, Spain.,Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain
| | - Pablo Ryan
- Hospital Universitario Infanta Leonor (HUIL). Vallecas, Madrid, Spain
| | - Salvador Resino
- Unidad de Infección Viral e Inmunidad. Centro Nacional de Microbiología - Instituto de Salud Carlos III, Majadahonda, Spain.
| |
Collapse
|
29
|
Jackson K, Holgate T, Tekoaua R, Nicholson S, Littlejohn M, Locarnini S. Evaluation of dried blood spots for hepatitis B and D serology and nucleic acid testing. J Med Virol 2019; 94:642-648. [PMID: 30977903 DOI: 10.1002/jmv.25485] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Revised: 03/21/2019] [Accepted: 04/07/2019] [Indexed: 12/11/2022]
Abstract
Areas with the highest burden of hepatitis B virus (HBV) infection are often low-middle-income countries with limited access to diagnosis due to isolation, affordability, and/or feasibility. Dried blood spots (DBSs) provide an alternative for remote areas where collection and transportation of serum is impractical. In this study, the application of DBS for serological and molecular detection of HBV and hepatitis D virus (HDV) was evaluated. Hepatitis B surface antigen was detected in 87 of 91 (95.6%) DBS. Seventeen of 21 (81%) had detectable HBeAg and 52 of 71 (73.2%) were anti-HBe positive. Anti-HD was detectable in 11 of 12 (91.6%) spiked control DBS after an initial failure to detect in patient DBS. HBV DNA was detected from 50 of 70 (71.4%) DBS with serum loads greater than 200 IU/mL in an in-house assay and 18 of 24 (75%) DBS with loads exceeding 389 IU/mL in a commercial assay. Using linear regression, HBV DNA loads from DBS were able to predict serum loads in 46 of 50 (92%) samples to within 1 log of actual serum load. HDV RNA was detected in 42 of 47 (89%) DBS with serum levels greater than 7200 IU/mL. DBSs are recommended for diagnosis of HBV, monitoring, and detection of high loads in pregnant women where peripheral blood testing remains unfeasible. Detection of HDV RNA from DBS may prove useful in endemic areas.
Collapse
Affiliation(s)
- Kathy Jackson
- Victorian Infectious Diseases Reference Laboratory, Royal Melbourne Hospital and WHO Regional Reference Laboratory for Hepatitis B/D, at The Peter Doherty Institute for Infection and Immunity, Melbourne, Victoria, Australia
| | - Thomas Holgate
- Victorian Infectious Diseases Reference Laboratory, Royal Melbourne Hospital and WHO Regional Reference Laboratory for Hepatitis B/D, at The Peter Doherty Institute for Infection and Immunity, Melbourne, Victoria, Australia
| | - Rosemary Tekoaua
- Tungaru Central Hospital, Ministry of Health and Medical Services, Tarawa, Republic of Kiribati
| | - Suellen Nicholson
- Victorian Infectious Diseases Reference Laboratory, Royal Melbourne Hospital and WHO Regional Reference Laboratory for Hepatitis B/D, at The Peter Doherty Institute for Infection and Immunity, Melbourne, Victoria, Australia
| | - Margaret Littlejohn
- Victorian Infectious Diseases Reference Laboratory, Royal Melbourne Hospital and WHO Regional Reference Laboratory for Hepatitis B/D, at The Peter Doherty Institute for Infection and Immunity, Melbourne, Victoria, Australia
| | - Stephen Locarnini
- Victorian Infectious Diseases Reference Laboratory, Royal Melbourne Hospital and WHO Regional Reference Laboratory for Hepatitis B/D, at The Peter Doherty Institute for Infection and Immunity, Melbourne, Victoria, Australia
| |
Collapse
|
30
|
Applicability of Oral Fluid and Dried Blood Spot for Hepatitis B Virus Diagnosis. Can J Gastroenterol Hepatol 2019; 2019:5672795. [PMID: 31058110 PMCID: PMC6463598 DOI: 10.1155/2019/5672795] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2018] [Accepted: 02/03/2019] [Indexed: 12/12/2022] Open
Abstract
Hepatitis B virus (HBV) is one of the major causes of chronic liver disease worldwide; however most of individuals are not aware about the infection. Oral fluid and dried blood spot (DBS) samples may be an alternative to serum to HBV diagnosis to increase the access to diagnosis in remote areas or high-risk groups. The main objective of this review is to give an insight about the usefulness of oral fluid and DBS for detecting HBV markers. Several groups have evaluated the detection of HBsAg, anti-HBc, and anti-HBs markers in oral fluid and DBS samples demonstrating 13 to 100% of sensitivity and specificity according different groups, sample collectors, and diagnosis assays. In the same way, HBV DNA detection using oral fluid and DBS samples demonstrate different values of sensitivity according type of collection, studied group, extraction, and detection methods. Thus, serological and molecular diagnostic tests demonstrated good performance for detecting HBV using oral fluid and DBS according some characteristics and could be useful to increase the access to the diagnosis of HBV.
Collapse
|
31
|
Evaluation of the Aptima HCV Quant Dx Assay Using Serum and Dried Blood Spots. J Clin Microbiol 2019; 57:JCM.00030-19. [PMID: 30760534 DOI: 10.1128/jcm.00030-19] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2019] [Accepted: 02/06/2019] [Indexed: 01/19/2023] Open
Abstract
Hepatitis C virus (HCV) RNA quantitation is the primary method by which active HCV infections are identified and the response to direct-acting antiviral therapy is monitored. This study describes the evaluation of the Aptima HCV Quant Dx assay (Aptima HCV) performed on the Panther system. The clinical performance of Aptima HCV was compared to that of the Cobas AmpliPrep/Cobas TaqMan HCV test v2.0 (CAP/CTM). Overall agreement was 84.9% (186/219) with a kappa statistic of 0.755 (standard error, 0.037; 95% confidence interval [CI], 0.682 to 0.828). Passing-Bablok regression of log10 IU/ml values revealed a regression line of Y = 1.163 × X - 0.991 (95% CI of the slope, 1.103 to 1.221, and intercept, -1.341 to -0.642). The 95% lower limit of detection (LLOD) for Aptima HCV on dried blood spot (DBS) samples was calculated to be 2.43 log10 IU/ml (267 IU/ml; 95% CI, 2.31 to 2.73 log10 IU/ml [204 to 540 IU/ml]). A comparison of Aptima HCV testing on paired DBS and serum specimens collected from patients at the time of routine blood collection for CAP/CTM demonstrated an overall agreement of 90.1% (82/91) with a kappa statistic of 0.657 (standard error, 0.101; 95% CI, 0.458 to 0.855). In conclusion, Aptima HCV provides a suitable alternative for HCV RNA testing on serum and DBS samples.
Collapse
|
32
|
Ghosh R, Hazarika NK. Detection of anti-hepatitis C virus and hepatitis C virus RNA in dried blood spot specimens using Whatman No. 1 filter paper. Indian J Med Microbiol 2018; 36:230-235. [PMID: 30084416 DOI: 10.4103/ijmm.ijmm_17_238] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Purpose Dried blood spot (DBS) specimen simplifies blood collection, processing, storage and shipment and may reduce the cost of testing for hepatitis C virus (HCV) infection. We wanted to see if DBS using a cheap filter paper is reliable alternative to serum for detection of anti-HCV and HCV RNA. Materials and Methods At a tertiary care hospital in Northeast India, we collected 91 paired DBS and serum specimens from patients at risk of HCV infection from July 2014 to June 2015. DBS was collected on Whatman No. 1 filter paper. After processing, the specimens were subjected to anti-HCV detection by a third-generation Enzyme-Linked Immunosorbent Assay (ELISA). The reactive DBS and serum specimens were further subjected to HCV RNA detection by polymerase chain reaction. The results were analysed in paired screen-positive study design. Results Anti-HCV was detected in 9 (9.9%) DBS specimens and 10 (10.9%) serum specimens. There was statistically significant (P < 0.0001) correlation between the optical density values of DBS and serum specimens (Pearson r = 0.9181, 95% confidence interval: 0.8781-0.9453). HCV RNA was detected in 5/9 (55.6%) reactive DBS and 9/10 (90.0%) reactive serum specimens. There was no correlation between HCV RNA levels in the DBS and the serum specimens. The relative sensitivity rate and the relative false-positive rate of DBS anti-HCV ELISA were 0.89 and 1.00, respectively. Conclusions DBS using Whatman No. 1 filter paper is quite reliable as serum for detection of anti-HCV. It can be useful in effective surveillance. However, it is not suitable for confirmation of chronic HCV infection.
Collapse
Affiliation(s)
- Ritapa Ghosh
- Vadodara Institute of Neurological Sciences, Vadodara, Gujarat; Department of Microbiology, Gauhati Medical College and Hospital, Guwahati, Assam, India
| | - Naba Kumar Hazarika
- Department of Microbiology, Gauhati Medical College and Hospital, Guwahati; Lab Operations, HLL Hindlabs Diagnostic Centre, Assam, India
| |
Collapse
|
33
|
Kenmoe S, Tagnouokam PAN, Nde CK, Mella-Tamko GF, Njouom R. Using dried blood spot for the detection of HBsAg and anti-HCV antibodies in Cameroon. BMC Res Notes 2018; 11:818. [PMID: 30446000 PMCID: PMC6240176 DOI: 10.1186/s13104-018-3931-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Accepted: 11/14/2018] [Indexed: 12/24/2022] Open
Abstract
Objective Dried blood spots (DBS) offer multiple benefits for collecting, storing and shipping whole blood samples. Our objective was to compare, for the first time in Africa, the performance of DBS with respect to plasma in the detection of Hepatitis B surface antigen (HBsAg) and antibodies to Hepatitis C Virus (anti-HCV) using Architect, Abbott Diagnostics. Results DBS had a sensitivity of 99%, a specificity of 100%, a positive predictive value of 99%, a negative predictive value of 100% and a kappa index of 0.99 for the detection of HBsAg. For anti-HCV detection, the sensitivity, specificity, positive predictive value, negative predictive value and kappa index were 99%, 98%, 98%, 99%, and 0.97, respectively. This study confirms that DBS may be a reliable alternative specimen type for HBV and HCV diagnosis.
Collapse
Affiliation(s)
- Sebastien Kenmoe
- Virology Department, Centre Pasteur du Cameroun, 451 Rue 2005, Yaoundé 2, P.O.Box 1274, Yaounde, Cameroon
| | | | | | | | - Richard Njouom
- Virology Department, Centre Pasteur du Cameroun, 451 Rue 2005, Yaoundé 2, P.O.Box 1274, Yaounde, Cameroon.
| |
Collapse
|
34
|
Derks L, Gassowski M, Nielsen S, An der Heiden M, Bannert N, Bock CT, Bremer V, Kücherer C, Ross S, Wenz B, Marcus U, Zimmermann R. Risk behaviours and viral infections among drug injecting migrants from the former Soviet Union in Germany: Results from the DRUCK-study. THE INTERNATIONAL JOURNAL OF DRUG POLICY 2018; 59:54-62. [PMID: 30005420 DOI: 10.1016/j.drugpo.2018.06.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Revised: 04/25/2018] [Accepted: 06/11/2018] [Indexed: 12/12/2022]
Abstract
BACKGROUND High prevalence of drug use and injection-related risk behaviours have been reported among former Soviet Union (FSU)-migrants. To investigate hepatitis C (HCV) and HIV seroprevalence and related risk behaviours in this subgroup in Germany, we compared first generation FSU-migrants and native Germans using data from a sero-behavioural survey of people who inject drugs (PWID). METHODS Current injectors were recruited using respondent-driven sampling in eight German cities in 2011-2014. Questionnaire-based interviews were conducted and dried blood spots collected and tested for anti-HCV, HCV-RNA, and anti-HIV1/2. Descriptive and multivariable analyses (MVA) were performed. RESULTS A total of 208 FSU-born and 1318 native German PWID were included in the analysis. FSU-migrants were younger than Germans (median age: 33 vs. 39 years), and more often male (83.1% vs. 75.9%, p = 0.022). HCV seroprevalence was 74.5% in FSU-migrants vs. 64.6% in Germans (p = 0.006), HIV seroprevalence was 5.8% and 4.6%, respectively (p = 0.443). The proportion of FSU-migrants reporting injecting-related risk behaviours was higher than among Germans: injecting daily (39.4% vs. 30.2%, p = 0.015), with friends (39.2% vs. 31.2%, p = 0.038), cocaine (32.7% vs. 23.8%, p = 0.044), more than one drug (18.2% vs. 9.6%, p = 0.006), and sharing filters/cookers (35.5% vs. 28.0%, p = 0.045). No statistically significant differences were observed in HIV/HCV testing rates (range: 50.7%-65.6%), opioid substitution treatment (43.9% vs. 50.5%), and access to clean needles/syringes (89.8% vs. 90.3%). In MVA, risk for HCV-infection was increased in male FSU-migrants compared to German males (OR 3.32, p = 0.006), no difference was identified between female FSU-migrants and German females (OR: 0.83, p = 0.633). CONCLUSION Male FSU-migrants were at highest risk of being HCV infected. Therefore, targeted actions are needed to ensure access and acceptance of harm reduction measures, including HCV-testing and -treatment for this subpopulation of PWID.
Collapse
Affiliation(s)
- Lineke Derks
- Department for Infectious Disease Epidemiology, Division for HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin, Germany
| | - Martyna Gassowski
- Department for Infectious Disease Epidemiology, Division for HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin, Germany
| | - Stine Nielsen
- Department for Infectious Disease Epidemiology, Division for HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin, Germany; Charité University Medicine, Berlin, Germany
| | - Matthias An der Heiden
- Department for Infectious Disease Epidemiology, Division for HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin, Germany
| | - Norbert Bannert
- Department of Infectious Diseases, Division for HIV and other Retroviruses, Robert Koch Institute, Berlin, Germany
| | - Claus-Thomas Bock
- Department of Infectious Diseases, Division for Viral Gastroenteritis and Hepatitis Pathogens and Enteroviruses, Robert Koch Institute, Berlin, Germany
| | - Viviane Bremer
- Department for Infectious Disease Epidemiology, Division for HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin, Germany
| | - Claudia Kücherer
- Department for Infectious Disease Epidemiology, Division for HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin, Germany
| | - Stefan Ross
- Institute of Virology, National Reference Centre for Hepatitis C, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Benjamin Wenz
- Department for Infectious Disease Epidemiology, Division for HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin, Germany
| | - Ulrich Marcus
- Department for Infectious Disease Epidemiology, Division for HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin, Germany
| | - Ruth Zimmermann
- Department for Infectious Disease Epidemiology, Division for HIV/AIDS, STI and Blood-borne Infections, Robert Koch Institute, Berlin, Germany.
| | | |
Collapse
|
35
|
Mahajan S, Choudhary MC, Kumar G, Gupta E. Evaluation of dried blood spot as an alternative sample collection method for hepatitis C virus RNA quantitation and genotyping using a commercial system. Virusdisease 2018; 29:141-146. [PMID: 29911146 PMCID: PMC6003055 DOI: 10.1007/s13337-018-0441-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2017] [Accepted: 02/26/2018] [Indexed: 01/05/2023] Open
Abstract
Dried blood spot (DBS) is a minimally invasive sampling method suitable for sample collection, storage and transportation in resource limited areas. Aim of this study was to compare the diagnostic utility of DBS with plasma sample for HCV RNA quantitation and genotyping using commercial systems. Plasma and DBS card spotted samples were collected from 95 HCV seropositive patients. Both types of samples were subjected to HCV RNA by real-time PCR (Abbott m2000rt, USA). Genotyping was performed using Abbott HCV genotype II kit (Abbott diagnostics, USA) in samples with viral load > 3 log10 IU/ml. In both plasma and DBS, 14 (14.7%) samples were negative and 81 (85.3%) were positive for HCV RNA. Median viral load in plasma (3.78; range 0-7.43) log10 IU/ml was comparable to DBS (3.93; range 0-7.24) log10 IU/ml. DBS demonstrated sensitivity and specificity of 97.5 and 85.7% respectively, with positive predictive value (PPV) of 97.5% and negative predictive value (NPV) of 85.7%. DBS showed good correlation (r2 = 0.866) and agreement (93.5%) with plasma. Genotyping in 20 patients showed 100% concordance between DBS and plasma samples. DBS showed good sensitivity and specificity as a sampling method for HCV RNA quantitation and genotyping.
Collapse
Affiliation(s)
- Supriya Mahajan
- Department of Clinical Virology, Institute of Liver and Biliary Sciences, D – 1, Vasant Kunj, New Delhi, 110070 India
| | - Manish Chandra Choudhary
- Department of Clinical Virology, Institute of Liver and Biliary Sciences, D – 1, Vasant Kunj, New Delhi, 110070 India
| | - Guresh Kumar
- Department of Clinical Research, Institute of Liver and Biliary Sciences, New Delhi, India
| | - Ekta Gupta
- Department of Clinical Virology, Institute of Liver and Biliary Sciences, D – 1, Vasant Kunj, New Delhi, 110070 India
| |
Collapse
|
36
|
Saludes V, Folch C, Morales-Carmona A, Ferrer L, Fernàndez-López L, Muñoz R, Jiménez M, Loureiro E, Fernández-Dávila P, Bascuñana E, Casabona J, Martró E. Community-based screening of hepatitis C with a one-step RNA detection algorithm from dried-blood spots: Analysis of key populations in Barcelona, Spain. J Viral Hepat 2018; 25:236-244. [PMID: 29053912 DOI: 10.1111/jvh.12809] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Accepted: 08/15/2017] [Indexed: 12/30/2022]
Abstract
Alternative strategies are required to enhance the diagnosis of silent hepatitis C virus (HCV) infections in key populations at risk. Among them, HCV prevalence and bio-behavioural data are scarce for HIV-negative men who have sex with men (MSM) and men and trans-women sex workers. We sought to describe and assess the potential benefits of a community-based one-step HCV screening and confirmatory strategy for these populations in Barcelona. The screening strategy based on a real-time RT-PCR assay for HCV-RNA detection in dried-blood spots (DBS) was validated and implemented in addition to an antibody point-of-care test in a community centre. HCV prevalence was assessed, and bio-behavioural data were collected. The molecular assay was precise, reproducible, sensitive and specific. Four HIV-negative MSM reported being currently infected (0.75% HCV self-reported prevalence). Implementation of DBS testing was easy, and acceptability was >95%, but no silent HCV case was diagnosed (N = 580). High-risk sexual practices and drug use for sex were reported frequently. HIV prevalence was 4.7% in MSM and 10% in sex workers. Self-reported prevalence of other STIs ranged from 11.3% to 36.2%. In conclusion, HCV-RNA testing in DBS showed a good performance, but the assessed one-step strategy does not seem beneficial in this setting. Although no silent HCV infections were detected, the observed high-risk behaviours and prevalence of other STIs suggest that HCV spread should be periodically monitored among these populations in Barcelona by means of behavioural surveillance, rapid antibody testing and molecular confirmation in DBS.
Collapse
Affiliation(s)
- V Saludes
- Microbiology Service, Germans Trias i Pujol University Hospital, Germans Trias i Pujol Health Sciences Research Institute (IGTP), Badalona, Spain.,Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain
| | - C Folch
- Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain.,Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | | | - L Ferrer
- Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain.,Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | - L Fernàndez-López
- Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain.,Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | - R Muñoz
- Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | - M Jiménez
- Microbiology Service, Germans Trias i Pujol University Hospital, Germans Trias i Pujol Health Sciences Research Institute (IGTP), Badalona, Spain
| | - E Loureiro
- Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain.,Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | - P Fernández-Dávila
- Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain.,Research Department, Stop Sida, Barcelona, Spain
| | - E Bascuñana
- Microbiology Service, Germans Trias i Pujol University Hospital, Germans Trias i Pujol Health Sciences Research Institute (IGTP), Badalona, Spain
| | - J Casabona
- Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain.,Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | - E Martró
- Microbiology Service, Germans Trias i Pujol University Hospital, Germans Trias i Pujol Health Sciences Research Institute (IGTP), Badalona, Spain.,Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain
| |
Collapse
|
37
|
Papatheodoridis GV, Hatzakis A, Cholongitas E, Baptista-Leite R, Baskozos I, Chhatwal J, Colombo M, Cortez-Pinto H, Craxi A, Goldberg D, Gore C, Kautz A, Lazarus JV, Mendão L, Peck-Radosavljevic M, Razavi H, Schatz E, Tözün N, van Damme P, Wedemeyer H, Yazdanpanah Y, Zuure F, Manns MP. Hepatitis C: The beginning of the end-key elements for successful European and national strategies to eliminate HCV in Europe. J Viral Hepat 2018; 25 Suppl 1:6-17. [PMID: 29508946 DOI: 10.1111/jvh.12875] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Accepted: 12/14/2017] [Indexed: 12/12/2022]
Abstract
Hepatitis C virus (HCV) infection is a major public health problem in the European Union (EU). An estimated 5.6 million Europeans are chronically infected with a wide range of variation in prevalence across European Union countries. Although HCV continues to spread as a largely "silent pandemic," its elimination is made possible through the availability of the new antiviral drugs and the implementation of prevention practices. On 17 February 2016, the Hepatitis B & C Public Policy Association held the first EU HCV Policy Summit in Brussels. This summit was an historic event as it was the first high-level conference focusing on the elimination of HCV at the European Union level. The meeting brought together the main stakeholders in the field of HCV: clinicians, patient advocacy groups, representatives of key institutions and regional bodies from across European Union; it served as a platform for one of the most significant disease elimination campaigns in Europe and culminated in the presentation of the HCV Elimination Manifesto, calling for the elimination of HCV in Europe by 2030. The launch of the Elimination Manifesto provides a starting point for action in order to make HCV and its elimination in Europe an explicit public health priority, to ensure that patients, civil society groups and other relevant stakeholders will be directly involved in developing and implementing HCV elimination strategies, to pay particular attention to the links between hepatitis C and social marginalization and to introduce a European Hepatitis Awareness Week.
Collapse
Affiliation(s)
- G V Papatheodoridis
- Medical School of National, Kapodistrian University of Athens, Athens, Greece
| | - A Hatzakis
- Medical School of National, Kapodistrian University of Athens, Athens, Greece
| | - E Cholongitas
- Medical School of National, Kapodistrian University of Athens, Athens, Greece
| | - R Baptista-Leite
- Institute of Health Sciences, Católica University of Portugal, Lisbon, Portugal.,Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, The Netherlands
| | | | - J Chhatwal
- Massachusetts General Hospital' s, Institute for Technology Assessment and Harvard Medical School, Boston, MA, USA
| | - M Colombo
- Clinical and Research Center Humanitas, Rozzano, Italy
| | - H Cortez-Pinto
- European Association for the Study of the Liver, Geneva, Switzerland.,Faculdade de Medicina, Universidade de Lisbon, Lisbon, Portugal
| | - A Craxi
- University of Palermo, Palermo, Italy
| | - D Goldberg
- School of Health and Life Sciences, Glasgow Caledonian University, Glasgow, Scotland, UK
| | - C Gore
- Hepatitis C Trust, World Hepatitis Alliance, London, UK
| | - A Kautz
- Leberhilfe Projekt gUG, Cologne, Germany
| | - J V Lazarus
- Barcelonai Institute for Global Health (ISGlobal), Hospital Clínic, University of Barcelona, Barcelona, Spain.,CHIP, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | - L Mendão
- Portuguese Activist Group for HIV/AIDS Treatment, Lisbon, Portugal.,European AIDS Treatment Group, Brussels, Belgium
| | | | - H Razavi
- Center for Disease Analysis, Lafayette, CO, USA
| | - E Schatz
- Correlation Network, Amsterdam, The Netherlands
| | - N Tözün
- Acibadem Mehmet Ali Aydinlar University, Istanbul, Turkey
| | - P van Damme
- Antwerp University, Antwerp, Belgium.,Viral Hepatitis Prevention Board, Antwerp, Belgium
| | | | | | - F Zuure
- Department of Infectious Diseases Research and Prevention, Public Health Service of Amsterdam, Amsterdam, The Netherlands.,Department of Internal Medicine, Amsterdam Infection and Immunity Institute (AI&II), Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - M P Manns
- Hannover Medical School, Hannover, Germany
| |
Collapse
|
38
|
García-Cisneros S, Olamendi-Portugal ML, Herrera-Ortiz A, Conde-González CJ, Lopez-Gatell H, Sánchez-Alemán MA. [Detection of antibodies against HIV from dry blood samples on filter paper]. SALUD PUBLICA DE MEXICO 2018; 59:602-603. [PMID: 29451623 DOI: 10.21149/8751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Señor editor: En los últimos años se ha incrementado el uso de muestras de sangre seca en papel filtro (dried blood spots, DBS) para detectar anticuerpos contra virus de la hepatitis C (VHC), virus dengue y VIH, entre otros...
Collapse
Affiliation(s)
- Santa García-Cisneros
- Centro de Investigación sobre Enfermedades Infecciosas, Instituto Nacional de Salud Pública. Cuernavaca, Morelos, México
| | - Ma Leonidez Olamendi-Portugal
- Centro de Investigación sobre Enfermedades Infecciosas, Instituto Nacional de Salud Pública. Cuernavaca, Morelos, México
| | - Antonia Herrera-Ortiz
- Centro de Investigación sobre Enfermedades Infecciosas, Instituto Nacional de Salud Pública. Cuernavaca, Morelos, México
| | - Carlos J Conde-González
- Centro de Investigación en Salud Poblacional, Instituto Nacional de Salud Pública. Cuernavaca, Morelos, México
| | - Hugo Lopez-Gatell
- Centro de Investigación sobre Enfermedades Infecciosas, Instituto Nacional de Salud Pública. Cuernavaca, Morelos, México
| | - Miguel A Sánchez-Alemán
- Centro de Investigación sobre Enfermedades Infecciosas, Instituto Nacional de Salud Pública. Cuernavaca, Morelos, México
| |
Collapse
|
39
|
Vázquez-Morón S, Ryan P, Ardizone-Jiménez B, Martín D, Troya J, Cuevas G, Valencia J, Jimenez-Sousa MA, Avellón A, Resino S. Evaluation of dried blood spot samples for screening of hepatitis C and human immunodeficiency virus in a real-world setting. Sci Rep 2018; 8:1858. [PMID: 29382904 PMCID: PMC5789840 DOI: 10.1038/s41598-018-20312-5] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Accepted: 01/15/2018] [Indexed: 01/05/2023] Open
Abstract
Both hepatitis C virus (HCV) infection and human immunodeficiency virus (HIV) infection are underdiagnosed, particularly in low-income countries and in difficult-to-access populations. Our aim was to develop and evaluate a methodology for the detection of HCV and HIV infection based on capillary dry blood spot (DBS) samples taken under real-world conditions. We carried out a cross-sectional study of 139 individuals (31 healthy controls, 68 HCV-monoinfected patients, and 40 HCV/HIV-coinfected patients). ELISA was used for anti-HCV and anti-HIV antibody detection; and SYBR Green RT-PCR was used for HCV-RNA detection. The HIV serological analysis revealed 100% sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The HCV serological analysis revealed a sensitivity of 92.6%, specificity of 100%, PPV of 100%, and NPV of 79.5%. Finally, the HCV-RNA detection test revealed a detection limit of 5 copies/µl with an efficiency of 100% and sensitivity of 99.1%, specificity of 100%, PPV of 100%, and NPV of 96.9%. In conclusion, our methodology was able to detect both HCV infection and HIV infection from the same DBS sample with good diagnostic performance. Screening for HCV and HIV using DBS might be a key strategy in the implementation of national programs for the control of both infections.
Collapse
Affiliation(s)
- Sonia Vázquez-Morón
- Laboratorio de Referencia e Investigación en Hepatitis Víricas, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain.
| | - Pablo Ryan
- Hospital Universitario Infanta Leonor (HUIL), Vallecas, Madrid, Spain
| | - Beatriz Ardizone-Jiménez
- Laboratorio de Referencia e Investigación en Hepatitis Víricas, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
| | | | - Jesus Troya
- Hospital Universitario Infanta Leonor (HUIL), Vallecas, Madrid, Spain
| | - Guillermo Cuevas
- Hospital Universitario Infanta Leonor (HUIL), Vallecas, Madrid, Spain
| | | | - María A Jimenez-Sousa
- Laboratorio de Referencia e Investigación en Hepatitis Víricas, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
| | - Ana Avellón
- Laboratorio de Referencia e Investigación en Hepatitis Víricas, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
| | - Salvador Resino
- Laboratorio de Referencia e Investigación en Hepatitis Víricas, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
| |
Collapse
|
40
|
Affiliation(s)
- Kapil Gupta
- Department of Biochemistry, Adesh Institute of Medical Sciences and Research, Bathinda, Punjab, India
| | - Rajiv Mahajan
- Department of Pharmacology, Adesh Institute of Medical Sciences and Research, Bathinda, Punjab, India
| |
Collapse
|
41
|
Lange B, Cohn J, Roberts T, Camp J, Chauffour J, Gummadi N, Ishizaki A, Nagarathnam A, Tuaillon E, van de Perre P, Pichler C, Easterbrook P, Denkinger CM. Diagnostic accuracy of serological diagnosis of hepatitis C and B using dried blood spot samples (DBS): two systematic reviews and meta-analyses. BMC Infect Dis 2017; 17:700. [PMID: 29143672 PMCID: PMC5688450 DOI: 10.1186/s12879-017-2777-y] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Dried blood spots (DBS) are a convenient tool to enable diagnostic testing for viral diseases due to transport, handling and logistical advantages over conventional venous blood sampling. A better understanding of the performance of serological testing for hepatitis C (HCV) and hepatitis B virus (HBV) from DBS is important to enable more widespread use of this sampling approach in resource limited settings, and to inform the 2017 World Health Organization (WHO) guidance on testing for HBV/HCV. METHODS We conducted two systematic reviews and meta-analyses on the diagnostic accuracy of HCV antibody (HCV-Ab) and HBV surface antigen (HBsAg) from DBS samples compared to venous blood samples. MEDLINE, EMBASE, Global Health and Cochrane library were searched for studies that assessed diagnostic accuracy with DBS and agreement between DBS and venous sampling. Heterogeneity of results was assessed and where possible a pooled analysis of sensitivity and specificity was performed using a bivariate analysis with maximum likelihood estimate and 95% confidence intervals (95%CI). We conducted a narrative review on the impact of varying storage conditions or limits of detection in subsets of samples. The QUADAS-2 tool was used to assess risk of bias. RESULTS For the diagnostic accuracy of HBsAg from DBS compared to venous blood, 19 studies were included in a quantitative meta-analysis, and 23 in a narrative review. Pooled sensitivity and specificity were 98% (95%CI:95%-99%) and 100% (95%CI:99-100%), respectively. For the diagnostic accuracy of HCV-Ab from DBS, 19 studies were included in a pooled quantitative meta-analysis, and 23 studies were included in a narrative review. Pooled estimates of sensitivity and specificity were 98% (CI95%:95-99) and 99% (CI95%:98-100), respectively. Overall quality of studies and heterogeneity were rated as moderate in both systematic reviews. CONCLUSION HCV-Ab and HBsAg testing using DBS compared to venous blood sampling was associated with excellent diagnostic accuracy. However, generalizability is limited as no uniform protocol was applied and most studies did not use fresh samples. Future studies on diagnostic accuracy should include an assessment of impact of environmental conditions common in low resource field settings. Manufacturers also need to formally validate their assays for DBS for use with their commercial assays.
Collapse
Affiliation(s)
- Berit Lange
- Division of Infectious Diseases, Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, Freiburg, Germany. .,Centre for Chronic Immunodeficiency, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, Freiburg, Germany.
| | - Jennifer Cohn
- Department of Infectious Diseases, University of Pennsylvania, PA, Philadelphia, USA
| | | | - Johannes Camp
- Division of Infectious Diseases, Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, Freiburg, Germany
| | | | - Nina Gummadi
- School of Medicine, Boston University, Boston, USA
| | - Azumi Ishizaki
- Global Hepatitis Programme, HIV Department, World Health Organization, Geneva, Switzerland
| | | | - Edouard Tuaillon
- Pathogenesis and Control of Chronic Infections UMR 1058 INSERM/Université Montpellier/Etablissement Français du Sang, INSERM, 34394, Montpellier Cedex 5, France.,Centre Hospitalier Universitaire (CHU) de Montpellier, Département de bactériologie-virologie, Montpellier, France
| | - Philippe van de Perre
- Pathogenesis and Control of Chronic Infections UMR 1058 INSERM/Université Montpellier/Etablissement Français du Sang, INSERM, 34394, Montpellier Cedex 5, France.,Centre Hospitalier Universitaire (CHU) de Montpellier, Département de bactériologie-virologie, Montpellier, France
| | - Christine Pichler
- Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Philippa Easterbrook
- Global Hepatitis Programme, HIV Department, World Health Organization, Geneva, Switzerland
| | | |
Collapse
|
42
|
Lange B, Roberts T, Cohn J, Greenman J, Camp J, Ishizaki A, Messac L, Tuaillon E, van de Perre P, Pichler C, Denkinger CM, Easterbrook P. Diagnostic accuracy of detection and quantification of HBV-DNA and HCV-RNA using dried blood spot (DBS) samples - a systematic review and meta-analysis. BMC Infect Dis 2017; 17:693. [PMID: 29143616 PMCID: PMC5688458 DOI: 10.1186/s12879-017-2776-z] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND The detection and quantification of hepatitis B (HBV) DNA and hepatitis C (HCV) RNA in whole blood collected on dried blood spots (DBS) may facilitate access to diagnosis and treatment of HBV and HCV infection in resource-poor settings. We evaluated the diagnostic performance of DBS compared to venous blood samples for detection and quantification of HBV-DNA and HCV-RNA in two systematic reviews and meta-analyses on the diagnostic accuracy of HBV DNA and HCV RNA from DBS compared to venous blood samples. METHODS We searched MEDLINE, Embase, Global Health, Web of Science, LILAC and Cochrane library for studies that assessed diagnostic accuracy with DBS. Heterogeneity was assessed and where appropriate pooled estimates of sensitivity and specificity were generated using bivariate analyses with maximum likelihood estimates and 95% confidence intervals. We also conducted a narrative review on the impact of varying storage conditions or different cut-offs for detection from studies that undertook this in a subset of samples. The QUADAS-2 tool was used to assess risk of bias. RESULTS In the quantitative synthesis for diagnostic accuracy of HBV-DNA using DBS, 521 citations were identified, and 12 studies met the inclusion criteria. Overall quality of studies was rated as low. The pooled estimate of sensitivity and specificity for HBV-DNA was 95% (95% CI: 83-99) and 99% (95% CI: 53-100), respectively. In the two studies that reported on cut-offs and limit of detection (LoD) - one reported a sensitivity of 98% for a cut-off of ≥2000 IU/ml and another reported a LoD of 914 IU/ml using a commercial assay. Varying storage conditions for individual samples did not result in a significant variation of results. In the synthesis for diagnostic accuracy of HCV-RNA using DBS, 15 studies met the inclusion criteria, and this included six additional studies to a previously published review. The pooled sensitivity and specificity was 98% (95% CI:95-99) and 98% (95% CI:95-99.0), respectively. Varying storage conditions resulted in a decrease in accuracy for quantification but not for reported positivity. CONCLUSIONS These findings show a high level of diagnostic performance for the use of DBS for HBV-DNA and HCV-RNA detection. However, this was based on a limited number and quality of studies. There is a need for development of standardized protocols by manufacturers on the use of DBS with their assays, as well as for larger studies on use of DBS conducted in different settings and with varying storage conditions.
Collapse
Affiliation(s)
- Berit Lange
- Division of Infectious Diseases, Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
- Centre for Chronic Immunodeficiency, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| | | | - Jennifer Cohn
- Department of Infectious Diseases, University of Pennsylvania, Philadelphia, PA, USA
| | - Jamie Greenman
- Department of Infectious Diseases, University of Pennsylvania, Philadelphia, PA, USA
| | - Johannes Camp
- Division of Infectious Diseases, Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Azumi Ishizaki
- Global Hepatitis Programme, HIV Department, World Health Organization, Geneva, Switzerland
| | - Luke Messac
- Department of Infectious Diseases, University of Pennsylvania, Philadelphia, PA, USA
| | - Edouard Tuaillon
- Pathogenesis and Control of Chronic Infections UMR 1058, INSERM/Université Montpellier/Etablissement Français du Sang, INSERM, 34394, Cedex 5, Montpellier, France
- Centre Hospitalier Universitaire (CHU) de Montpellier, département de bactériologie-virologie, Montpellier, France
| | - Philippe van de Perre
- Pathogenesis and Control of Chronic Infections UMR 1058, INSERM/Université Montpellier/Etablissement Français du Sang, INSERM, 34394, Cedex 5, Montpellier, France
- Centre Hospitalier Universitaire (CHU) de Montpellier, département de bactériologie-virologie, Montpellier, France
| | - Christine Pichler
- Division of Infectious Diseases, Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | | | - Philippa Easterbrook
- Global Hepatitis Programme, HIV Department, World Health Organization, Geneva, Switzerland
| |
Collapse
|
43
|
Haussig JM, Nielsen S, Gassowski M, Bremer V, Marcus U, Wenz B, Bannert N, Bock CT, Zimmermann R. A large proportion of people who inject drugs are susceptible to hepatitis B: Results from a bio-behavioural study in eight German cities. Int J Infect Dis 2017; 66:5-13. [PMID: 29097248 DOI: 10.1016/j.ijid.2017.10.008] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Revised: 10/10/2017] [Accepted: 10/14/2017] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND People who inject drugs (PWID) are at high risk of hepatitis B virus (HBV) infection by sharing needles and drug use paraphernalia. In Germany, no routine surveillance of HBV prevalence and vaccination coverage among PWID exists. METHODS Socio-demographic and behavioural data were collected between 2011 and 2014 through face-to-face interviews, during a bio-behavioural survey of PWID recruited in eight German cities. Dried blood spots (DBS) prepared with capillary blood were tested for HBV markers. Factors associated with past/current HBV infection and vaccination status were analysed by univariable and multivariable analysis using logistic regression. The validity of self-reported HBV infection and vaccination status was analysed by comparison to the laboratory results. RESULTS Among 2077 participants, the prevalence of current HBV infection was 1.1%, of past HBV infection was 24%, and of vaccine-induced HBV antibodies was 32%. No detectable HBV antibodies were found in 43%. HBV infection status was significantly associated with study city, age, years of injecting, use of stimulants, migration status, and homelessness; HBV vaccination status was significantly associated with study city, age, and level of education. Correct infection status was reported by 71% and correct vaccination status by 45%. CONCLUSIONS HBV seroprevalence among PWID was about five times higher than in the general population in Germany, confirming PWID as an important risk group. Targeted information campaigns on HBV and HBV prevention for PWID and professionals in contact with PWID need to be intensified. Routinely offered HBV vaccination during imprisonment and opioid substitution therapy would likely improve vaccination rates among PWID.
Collapse
Affiliation(s)
- J M Haussig
- Postgraduate Training for Applied Epidemiology (PAE), Robert Koch Institute, Berlin, Germany; European Programme for Intervention Epidemiology Training (EPIET), European Centre for Disease Prevention and Control, Stockholm, Sweden; Department for Infectious Disease Epidemiology, Robert Koch Institute, Berlin, Germany
| | - S Nielsen
- Department for Infectious Disease Epidemiology, Robert Koch Institute, Berlin, Germany; Charité University Medicine, Berlin, Germany
| | - M Gassowski
- Department for Infectious Disease Epidemiology, Robert Koch Institute, Berlin, Germany
| | - V Bremer
- Department for Infectious Disease Epidemiology, Robert Koch Institute, Berlin, Germany
| | - U Marcus
- Department for Infectious Disease Epidemiology, Robert Koch Institute, Berlin, Germany
| | - B Wenz
- Department for Infectious Disease Epidemiology, Robert Koch Institute, Berlin, Germany
| | - N Bannert
- Department of Infectious Diseases, Robert Koch Institute, Berlin, Germany
| | - C T Bock
- Department of Infectious Diseases, Robert Koch Institute, Berlin, Germany
| | - R Zimmermann
- Department for Infectious Disease Epidemiology, Robert Koch Institute, Berlin, Germany.
| | | |
Collapse
|
44
|
van Loo IHM, Dukers-Muijrers NHTM, Heuts R, van der Sande MAB, Hoebe CJPA. Screening for HIV, hepatitis B and syphilis on dried blood spots: A promising method to better reach hidden high-risk populations with self-collected sampling. PLoS One 2017; 12:e0186722. [PMID: 29053737 PMCID: PMC5650165 DOI: 10.1371/journal.pone.0186722] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Accepted: 10/08/2017] [Indexed: 01/28/2023] Open
Abstract
Introduction Many people at high risk for sexually transmitted infections (STIs), e.g., men who have sex with men (MSM), are not optimally reached by current sexual health care systems with testing. To facilitate testing by home-based sampling or sampling in outreach setting we evaluated dried blood spots (DBS), a method for self-collected blood sampling for serological screening of HIV, hepatitis B (HBV) and syphilis. The aims of this study were to assess the acceptability and feasibility of self-collected DBS and to compare the test results for screening of HIV, HBV and syphilis from DBS with blood drawn by venous puncture. Methods DBS were collected from men who have sex with men (MSM), visiting the STI clinic of the public health service South Limburg (n = 183) and HIV positive and HBV positive patients (n = 34), visiting the outpatient clinics of the Maastricht University Medical Centre in the period January 2012–April 2015. The 93 first participating MSM visiting the STI clinic were asked to fill in a questionnaire about the feasibility and acceptability about self-collection of DBS in a setting without going to a health care facility and were asked to collect the DBS themselves. Serological screening tests for HIV (HIV combi PT, Roche), HBV (HBsAg, Roche) and syphilis (Treponema pallidum Ig, Biokit 3.0) were performed on DBS and on blood drawn by venous puncture, which was routinely taken for screening. Results In total 217 participants were included in the study with a median age of 40 years (range between 17–80). Of MSM 84% agreed that it was clear and easy to do the finger-prick, while 53% agreed that it was clear and easy to apply the blood onto the DBS card. Also, 80% of MSM would use the bloodspot test again. In 91% (198) of DBS, sufficient material was collected to perform the three tests. No difference was observed in DBS quality between self-collected DBS and health care worker collected DBS. For HIV (n = 195 DBS-serum pairs) sensitivity and specificity were 100%. For HBV the sensitivity for HBsAg (n = 202) was 90% and specificity was 99%. For syphilis (n = 191) the sensitivity of the DBS was 93% with a specificity of 99%. Analysis of the DBS of HIV positive participants (n = 38) did show similar test performance for HBV and syphilis as in HIV negatives. Conclusion DBS is an acceptable self-sampling method for MSM, as there was no difference in DBS quality in self-collected and health care worker collected DBS. Test performance, i.e., its high sensitivity (>90%) and specificity (>99%) measures show that DBS is a valid alternative for venous blood puncture. Especially when DBS is combined with home-collected sampling for Chlamydia trachomatis and Neisseria gonorrhoeae, complete STI screening can be done in outreach setting and/or home-collected sampling in MSM.
Collapse
Affiliation(s)
- Inge H. M. van Loo
- Department of Medical Microbiology, Maastricht University Medical Centre, Maastricht, The Netherlands
- Care and Public Health Research Institute (CAPHRI), Maastricht University, Maastricht, The Netherlands
- * E-mail:
| | - Nicole H. T. M. Dukers-Muijrers
- Department for Sexual Health, Infectious Diseases and Environmental Health, Public Health Service South Limburg, Geleen, The Netherlands
| | - Rosalie Heuts
- Department of Medical Microbiology, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Marianne A. B. van der Sande
- Centre Infectious Disease Control, National Institute for Public Health and the Environment, Bilthoven, The Netherlands
- Julius Center, University Medical Center Utrecht, Utrecht, The Netherlands
- Institute of Tropical Medicine, Antwerp, Belgium
| | - Christian J. P. A. Hoebe
- Department of Medical Microbiology, Maastricht University Medical Centre, Maastricht, The Netherlands
- Care and Public Health Research Institute (CAPHRI), Maastricht University, Maastricht, The Netherlands
- Department for Sexual Health, Infectious Diseases and Environmental Health, Public Health Service South Limburg, Geleen, The Netherlands
| |
Collapse
|
45
|
Muzembo BA, Mbendi NC, Nakayama SF. Systematic review with meta-analysis: performance of dried blood spots for hepatitis C antibodies detection. Public Health 2017; 153:128-136. [PMID: 29035801 DOI: 10.1016/j.puhe.2017.08.008] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2017] [Revised: 07/10/2017] [Accepted: 08/21/2017] [Indexed: 12/30/2022]
Abstract
OBJECTIVES Dried blood spots (DBS) specimens can be used for hepatitis C virus (HCV) infection screening in cases where serum specimens are difficult to obtain. However, uncertainties surround the sensitivity and specificity of DBS for HCV antibodies (anti-HCV) serology testing. We aimed to evaluate the accuracy of DBS use to screen for HCV infection. STUDY DESIGN We carried out a systematic review and meta-analysis. METHODS Medline and EMBASE databases were searched for articles published between 1989 and November 2016. We included studies comparing DBS to plasma/serum specimens to detect anti-HCV in adults. Two authors extracted data and assessed the quality of the studies using an adapted standards for reporting diagnostic accuracy studies (STARD) and independently checked the data for accuracy. Meta-analysis was computed with the bivariate and the hierarchical summary receiver-operating characteristic models. RESULTS Twelve studies (3307 specimens) were analyzed, where 11 of them evaluated the anti-HCV using enzyme immunoassays (EIAs), and the remaining one used rapid diagnostic tests. The studies were mostly case-controls (83.3%) and from developed countries (66.7%). The overall pooled sensitivity (95% confidence interval; CI) and specificity (95% CI) of DBS to detect anti-HCV was 98.1% (96.1-99.1%) and 99.7% (98.9-99.9%), respectively. In studies using EIAs, the pooled sensitivity and specificity were 97.3% (94.3-98.8%) and 99.6% (98.5-99.9%), respectively. Considering only studies using EIAs, sensitivity analysis excluding one study carried out in people who inject drugs showed the pooled sensitivity of 97.8% (96.2-98.8%) and specificity of 99.5% (98.5-99.9%). CONCLUSIONS In testing for anti-HCV by means of EIAs, the efficacy of DBS is found to be similar or slightly lower than that of serum specimens. However, the risk of finding negative and positive results that are both false when using DBS remains present. Therefore, further work including optimal storage and processing methodologies are recommended. This is to help establish consensus guidelines for use of DBS specimens for anti-HCV screening.
Collapse
Affiliation(s)
- B A Muzembo
- Center for Health and Environmental Risk Research, National Institute for Environmental Studies, Tsukuba, Japan.
| | - N C Mbendi
- Gastroenterology Department, Kinshasa University, Kinshasa, DR Congo
| | - S F Nakayama
- Center for Health and Environmental Risk Research, National Institute for Environmental Studies, Tsukuba, Japan
| |
Collapse
|
46
|
No significant HTLV seroprevalence in German people who inject drugs. PLoS One 2017; 12:e0183496. [PMID: 28829831 PMCID: PMC5567501 DOI: 10.1371/journal.pone.0183496] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Accepted: 08/04/2017] [Indexed: 12/28/2022] Open
Abstract
Background Although human T-lymphotropic virus (HTLV) is transmitted via the same routes as human immunodeficiency virus (HIV), its worldwide seroprevalence differs drastically because HTLV is transmitted mainly via infected cells rather than free virus. The sharing of needles and other equipment places people who inject drugs (PWID) at particularly high-risk for such blood-borne diseases. Methods To validate the methodology used to process and analyze the dried blood spots (DBS) utilized in the study, dried serum spots (DSS) with dilutions of sera from known HTLV infected individuals were analyzed by ELISA and Western blot. DBS collected between 2011 and 2015 from 2,077 PWID in eight German cities recruited by respondent-driven sampling were tested for HTLV-specific antibodies. Results The validation demonstrated that the use of DSS allowed identification of samples with even low titers of HTLV-specific antibodies, although a confirmatory Western blot with an additional venous blood sample would often be required. Despite numerous HIV and HCV positive individuals being identified within the study population, none tested positive for HTLV. Conclusion While the HIV and HCV prevalences in German PWID are comparable to those in other European countries, the very low prevalence of HTLV reflects the situation in the general population.
Collapse
|
47
|
Flores GL, Cruz HM, Potsch DV, May SB, Brandão-Mello CE, Pires MMA, Pilotto JH, Lewis-Ximenez LL, Lampe E, Villar LM. Evaluation of HBsAg and anti-HBc assays in saliva and dried blood spot samples according HIV status. J Virol Methods 2017; 247:32-37. [PMID: 28506632 DOI: 10.1016/j.jviromet.2017.05.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 04/22/2017] [Accepted: 05/09/2017] [Indexed: 02/07/2023]
Abstract
Influence of HIV status in HBV markers detection in saliva and dried blood spots (DBS) was not well established. This study aims to evaluate the performance of optimized commercial immunoassay for identifying HBsAg and anti-HBc in saliva and DBS according HIV status. A sum of 535 individuals grouped as HIV+, HBV+, HIV/HBV+ and HIV/HBV- were recruited where 347 and 188 were included for HBsAg and anti-HBc evaluation, respectively. Serum, DBS collected in Whatman 903 paper and saliva obtained using salivette device were analyzed using EIA. Increased sample volume and ROC curve analysis for cut off determination were used for DBS and saliva testing. HBsAg detection in saliva and DBS exhibited sensitivities of 80.9% and 85.6% and specificities of 86.8% and 96.3%. Sensitivity of anti-HBc in saliva and DBS were 82.4% and 76.9% and specificities in saliva and DBS were 96.9% and 91.7%. Low sensitivities were observed for HBsAg (62%) and anti-HBc (47%) detection in saliva of HIV/HBV+ individuals. OD values were also lower for HBsAg detection in DBS and saliva of HIV/HBV+ individuals compared to their serum samples. Statistical significance was found for sensitivities in HBsAg detection between saliva and DBS demonstrating high sensitivity for DBS specimens. In conclusion, HIV status or antiretroviral treatment appears to interfere in the performance of HBsAg and anti-HBc detection in DBS and saliva samples using the adapted commercial EIA.
Collapse
Affiliation(s)
- Geane Lopes Flores
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil
| | - Helena Medina Cruz
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil
| | - Denise Vigo Potsch
- Clementino Fraga Filho Hospital, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Silvia Beatriz May
- Clementino Fraga Filho Hospital, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | | | | | - Jose Henrique Pilotto
- Nova Iguaçu General Hospital & AIDS and Molecular Immunology Laboratory, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil
| | | | - Elisabeth Lampe
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil
| | - Livia Melo Villar
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil.
| |
Collapse
|
48
|
Fernandes SC, Walz JA, Wilson DJ, Brooks JC, Mace CR. Beyond Wicking: Expanding the Role of Patterned Paper as the Foundation for an Analytical Platform. Anal Chem 2017; 89:5654-5664. [PMID: 28406607 DOI: 10.1021/acs.analchem.6b03860] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
While a number of assays for soluble analytes have been developed using paper-based microfluidic devices, the detection and analysis of blood cells has remained an outstanding challenge. In this Feature, we discuss how the properties of paper determine the performance of paper-based microfluidic devices and permit the design of cellular assays, which can ultimately impact disparities in healthcare that exist in limited-resource settings.
Collapse
Affiliation(s)
- Syrena C Fernandes
- Department of Chemistry, Tufts University , 62 Talbot Avenue, Medford, Massachusetts 02155, United States
| | - Jenna A Walz
- Department of Chemistry, Tufts University , 62 Talbot Avenue, Medford, Massachusetts 02155, United States
| | - Daniel J Wilson
- Department of Chemistry, Tufts University , 62 Talbot Avenue, Medford, Massachusetts 02155, United States
| | - Jessica C Brooks
- Department of Chemistry, Tufts University , 62 Talbot Avenue, Medford, Massachusetts 02155, United States
| | - Charles R Mace
- Department of Chemistry, Tufts University , 62 Talbot Avenue, Medford, Massachusetts 02155, United States
| |
Collapse
|
49
|
Kyle JE, Casey CP, Stratton KG, Zink EM, Kim YM, Zheng X, Monroe ME, Weitz KK, Bloodsworth KJ, Orton DJ, Ibrahim YM, Moore RJ, Lee CG, Pedersen C, Orwoll E, Smith RD, Burnum-Johnson KE, Baker ES. Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2017; 31:447-456. [PMID: 27958645 PMCID: PMC5292309 DOI: 10.1002/rcm.7808] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 11/27/2016] [Accepted: 12/08/2016] [Indexed: 05/17/2023]
Abstract
RATIONALE The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as the smaller blood volume required, storage at room temperature, and ability to sample in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. METHODS Here we analyzed the stability of polar metabolites and lipids in DBS samples collected in 2000-2001 and stored at room temperature. The identified and statistically significant molecules were then compared to matched serum samples stored at -80°C to determine if the DBS samples could be effectively used in a longitudinal study following metabolic disease. RESULTS A total of 400 polar metabolites and lipids were identified in the serum and DBS samples using gas chromatograph/mass spectrometry (GC/MS), liquid chromatography (LC)/MS, and LC/ion mobility spectrometry-MS (LC/IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant metabolite was conserved in a case-control study of older diabetic males with low amounts of high-density lipoproteins and high body mass indices, triacylglycerides and glucose levels when compared to non-diabetic patients with normal levels, indicating that degradation in the DBS samples affects polar metabolite quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, 36 statistically significant lipids correlated in both sample types. CONCLUSIONS The difference in the number of statistically significant polar metabolites and lipids indicated that the lipids did not degrade to as great of a degree as the polar metabolites in the DBS samples and lipid quantitation was still possible. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Jennifer E. Kyle
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Cameron P. Casey
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Kelly G. Stratton
- National Security Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Erika M. Zink
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Young-Mo Kim
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Xueyun Zheng
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Matthew E. Monroe
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Karl K. Weitz
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Kent J. Bloodsworth
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Daniel J. Orton
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Yehia M. Ibrahim
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Ronald J. Moore
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | - Christine G. Lee
- Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland, OR
- Research Service, Portland Veterans Affairs Medical Center, Portland, OR
| | - Catherine Pedersen
- Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland, OR
| | - Eric Orwoll
- Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland, OR
| | - Richard D. Smith
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| | | | - Erin S. Baker
- Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA
| |
Collapse
|
50
|
Flores GL, Cruz HM, Marques VA, Villela-Nogueira CA, Potsch DV, May SB, Brandão-Mello CE, Pires MMA, Pilotto JH, Pollo-Flores P, Esberard EBC, Ivantes C, Lewis-Ximenez LL, Lampe E, Villar LM. Performance of ANTI-HCV testing in dried blood spots and saliva according to HIV status. J Med Virol 2017; 89:1435-1441. [PMID: 28165155 DOI: 10.1002/jmv.24777] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 12/19/2016] [Accepted: 01/18/2017] [Indexed: 12/15/2022]
Abstract
The use of saliva and dried blood spots (DBS) could increase access to HCV diagnosis for high-risk populations, such as HIV-infected individuals, but the performance of these assays has not been well established in this group. This study aims to evaluate HIV status, particularly TCD4+ cell count and viral load, in the performance of anti-HCV testing using DBS and saliva. A total of 961 individuals classified as HCV+, HIV+, or HIV/HCV+, as well as negative controls, donated serum, DBS, and saliva samples for anti-HCV testing using a commercial enzyme immunoassay. Sample volume was modified for DBS and saliva, and an ROC curve was used for cut-off determination in saliva. Anti-HCV sensitivities were greater than 93% using DBS and saliva in the HCV+ group, while they were 83.3% and 95.6% for HCV/HIV+ individuals for DBS and saliva assays, respectively. Specificity varied from 91.7% to 100% using saliva and DBS in HIV monoinfected and control subjects. When only anti-HCV/HCV RNA+ serum samples, that is, true positives, were considered, the sensitivities were 98.3% and 100% for DBS and saliva, respectively, in the HCV+ group and 91.6% and 94.8% for DBS and saliva, respectively, in the HIV/HCV+ group. High absorbance values were observed among those presenting with HCV RNA in serum and low HIV viral load (less than 50 copies/mL). In conclusion, DBS and saliva samples could be used for anti-HCV detection, particularly to identify active HCV cases, but low sensitivity was observed for anti-HCV testing using DBS in the HIV/HCV+ group.
Collapse
Affiliation(s)
- Geane Lopes Flores
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil
| | - Helena Medina Cruz
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil
| | | | | | - Denise Vigo Potsch
- Clementino Fraga Filho Hospital, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Silvia Beatriz May
- Clementino Fraga Filho Hospital, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | | | | | - Jose Henrique Pilotto
- Nova Iguaçu General Hospital & AIDS and Molecular Immunology Laboratory, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil
| | | | | | | | | | - Elisabeth Lampe
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil
| | - Livia Melo Villar
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil
| |
Collapse
|