1
|
Platonova AA, Aleksandrova PV, Alekseeva AI, Kudryavtseva SP, Zotov AK, Zaytsev KI, Dolganov KB, Reshetov IV, Kurlov VN, Dolganova IN. Feasibility of Monitoring Tissue Properties During Microcirculation Disorder Using a Compact Fiber-Based Probe With Sapphire Tip. JOURNAL OF BIOPHOTONICS 2024; 17:e202400368. [PMID: 39354878 DOI: 10.1002/jbio.202400368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Revised: 09/10/2024] [Accepted: 09/13/2024] [Indexed: 10/03/2024]
Abstract
One of the urgent tasks of modern medicine is to detect microcirculation disorder during surgery to avoid possible consequences like tissue hypoxia, ischemia, and necrosis. To address this issue, in this article, we propose a compact probe with sapphire tip and optical sensing based on the principle of spatially resolved diffuse reflectance analysis. It allows for intraoperative measurement of tissue effective attenuation coefficient and its alteration during the changes of tissue condition, caused by microcirculation disorder. The results of experimental studies using (1) a tissue-mimicking phantom based on lipid emulsion and hemoglobin and (2) a model of hindlimb ischemia performed in a rat demonstrated the ability to detect rapid changes of tissue attenuation confirming the feasibility of the probe to sense the stressful exposure. Due to a compact design of the probe, it could be useful for rather wide surgical operations and diagnostic purposes as an auxiliary instrument.
Collapse
Affiliation(s)
- Alina A Platonova
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | - Polina V Aleksandrova
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | - Anna I Alekseeva
- Avtsyn Research Institute of Human Morphology of FSBSI "Petrovsky National Research Centre of Surgery", Moscow, Russia
| | - Sophya P Kudryavtseva
- Sechenov First Moscow State Medical University, N.V. Sklifosovskiy Institute of Clinical Medicine, Moscow, Russia
| | - Arsen K Zotov
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
- Osipyan Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia
| | - Kirill I Zaytsev
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | - Kirill B Dolganov
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | - Igor V Reshetov
- Sechenov First Moscow State Medical University, Institute for Cluster Oncology, Moscow, Russia
| | - Vladimir N Kurlov
- Osipyan Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia
| | - Irina N Dolganova
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
- Osipyan Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia
| |
Collapse
|
2
|
Mireles M, Morales-Dalmau J, Johansson JD, Vidal-Rosas EE, Vilches C, Martínez-Lozano M, Sanz V, de Miguel I, Casanovas O, Quidant R, Durduran T. Non-invasive and quantitative in vivo monitoring of gold nanoparticle concentration and tissue hemodynamics by hybrid optical spectroscopies. NANOSCALE 2019; 11:5595-5606. [PMID: 30860518 DOI: 10.1039/c8nr08790c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Owing to their unique combination of chemical and physical properties, inorganic nanoparticles show a great deal of potential as suitable agents for early diagnostics and less invasive therapies. Yet, their translation to the clinic has been hindered, in part, by the lack of non-invasive methods to quantify their concentration in vivo while also assessing their effect on the tissue physiology. In this work, we demonstrate that diffuse optical techniques, employing near-infrared light, have the potential to address this need in the case of gold nanoparticles which support localized surface plasmons. An orthoxenograft mouse model of clear cell renal cell carcinoma was non-invasively assessed by diffuse reflectance and correlation spectroscopies before and over several days following a single intravenous tail vein injection of polyethylene glycol-coated gold nanorods (AuNRs-PEG). Our platform enables to resolve the kinetics of the AuNR-PEG uptake by the tumor in quantitative agreement with ex vivo inductively coupled plasma mass spectroscopy. Furthermore, it allows for the simultaneous monitoring of local tissue hemodynamics, enabling us to conclude that AuNRs-PEG do not significantly alter the animal physiology. We note that the penetration depth of this current probe was a few millimeters but can readily be extended to centimeters, hence gaining clinical relevance. This study and the methodology presented here complement the nanomedicine toolbox by providing a flexible platform, extendable to other absorbing agents that can potentially be translated to human trials.
Collapse
Affiliation(s)
- Miguel Mireles
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Barcelona, Spain.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Portable Near-Infrared Technologies and Devices for Noninvasive Assessment of Tissue Hemodynamics. JOURNAL OF HEALTHCARE ENGINEERING 2019; 2019:3750495. [PMID: 30891170 PMCID: PMC6390246 DOI: 10.1155/2019/3750495] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 12/24/2018] [Accepted: 01/14/2019] [Indexed: 12/29/2022]
Abstract
Tissue hemodynamics, including the blood flow, oxygenation, and oxygen metabolism, are closely associated with many diseases. As one of the portable optical technologies to explore human physiology and assist in healthcare, near-infrared diffuse optical spectroscopy (NIRS) for tissue oxygenation measurement has been developed for four decades. In recent years, a dynamic NIRS technology, namely, diffuse correlation spectroscopy (DCS), has been emerging as a portable tool for tissue blood flow measurement. In this article, we briefly describe the basic principle and algorithms for static NIRS and dynamic NIRS (i.e., DCS). Then, we elaborate on the NIRS instrumentation, either commercially available or custom-made, as well as their applications to physiological studies and clinic. The extension of NIRS/DCS from spectroscopy to imaging was depicted, followed by introductions of advanced algorithms that were recently proposed. The future prospective of the NIRS/DCS and their feasibilities for routine utilization in hospital is finally discussed.
Collapse
|
4
|
Zirak P, Gregori-Pla C, Blanco I, Fortuna A, Cotta G, Bramon P, Serra I, Mola A, Solà-Soler J, Giraldo-Giraldo BF, Durduran T, Mayos M. Characterization of the microvascular cerebral blood flow response to obstructive apneic events during night sleep. NEUROPHOTONICS 2018; 5:045003. [PMID: 30681667 PMCID: PMC6215085 DOI: 10.1117/1.nph.5.4.045003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2018] [Accepted: 10/10/2018] [Indexed: 05/09/2023]
Abstract
Obstructive apnea causes periodic changes in cerebral and systemic hemodynamics, which may contribute to the increased risk of cerebrovascular disease of patients with obstructive sleep apnea (OSA) syndrome. The improved understanding of the consequences of an apneic event on the brain perfusion may improve our knowledge of these consequences and then allow for the development of preventive strategies. Our aim was to characterize the typical microvascular, cortical cerebral blood flow (CBF) changes in an OSA population during an apneic event. Sixteen patients (age 58 ± 8 years , 75% male) with a high risk of severe OSA were measured with a polysomnography device and with diffuse correlation spectroscopy (DCS) during one night of sleep with 1365 obstructive apneic events detected. All patients were later confirmed to suffer from severe OSA syndrome with a mean of 83 ± 15 apneas and hypopneas per hour. DCS has been shown to be able to characterize the microvascular CBF response to each event with a sufficient contrast-to-noise ratio to reveal its dynamics. It has also revealed that an apnea causes a peak increase of microvascular CBF ( 30 ± 17 % ) at the end of the event followed by a drop ( - 20 ± 12 % ) similar to what was observed in macrovascular CBF velocity of the middle cerebral artery. This study paves the way for the utilization of DCS for further studies on these populations.
Collapse
Affiliation(s)
- Peyman Zirak
- ICFO-Institut de Ciències Fotòniques, Barcelona Institute of Science and Technology, Barcelona, Spain
| | - Clara Gregori-Pla
- ICFO-Institut de Ciències Fotòniques, Barcelona Institute of Science and Technology, Barcelona, Spain
- Address all correspondence to: Clara Gregori-Pla, E-mail:
| | - Igor Blanco
- ICFO-Institut de Ciències Fotòniques, Barcelona Institute of Science and Technology, Barcelona, Spain
| | - Ana Fortuna
- Hospital de la Santa Creu i Sant Pau, Department of Respiratory Medicine, Sleep Unit, Barcelona, Spain
| | - Gianluca Cotta
- ICFO-Institut de Ciències Fotòniques, Barcelona Institute of Science and Technology, Barcelona, Spain
| | - Pau Bramon
- ICFO-Institut de Ciències Fotòniques, Barcelona Institute of Science and Technology, Barcelona, Spain
| | - Isabel Serra
- Centre de Recerca Matemàtica (CRM), Bellaterra, Spain
| | - Anna Mola
- Hospital de la Santa Creu i Sant Pau, Department of Respiratory Medicine, Sleep Unit, Barcelona, Spain
| | - Jordi Solà-Soler
- Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, Department of Automatic Control (ESAII), Barcelona, Spain
- The Barcelona Institute of Science and Technology, Institute for Bioengineering of Catalonia (IBEC), Barcelona, Spain
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain
| | - Beatriz F. Giraldo-Giraldo
- Universitat Politècnica de Catalunya (UPC)-Barcelona Tech, Department of Automatic Control (ESAII), Barcelona, Spain
- The Barcelona Institute of Science and Technology, Institute for Bioengineering of Catalonia (IBEC), Barcelona, Spain
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, Barcelona Institute of Science and Technology, Barcelona, Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), Barcelona, Spain
| | - Mercedes Mayos
- Hospital de la Santa Creu i Sant Pau, Department of Respiratory Medicine, Sleep Unit, Barcelona, Spain
- CIBER Enfermedades Respiratorias (CibeRes) (CB06/06), Madrid, Spain
| |
Collapse
|
5
|
Proctor AR, Ramirez GA, Han S, Liu Z, Bubel TM, Choe R. Validation of diffuse correlation spectroscopy sensitivity to nicotinamide-induced blood flow elevation in the murine hindlimb using the fluorescent microsphere technique. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-9. [PMID: 29595019 PMCID: PMC5873645 DOI: 10.1117/1.jbo.23.3.035006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Accepted: 03/06/2018] [Indexed: 05/15/2023]
Abstract
Nicotinamide has been shown to affect blood flow in both tumor and normal tissues, including skeletal muscle. Intraperitoneal injection of nicotinamide was used as a simple intervention to test the sensitivity of noninvasive diffuse correlation spectroscopy (DCS) to changes in blood flow in the murine left quadriceps femoris skeletal muscle. DCS was then compared with the gold-standard fluorescent microsphere (FM) technique for validation. The nicotinamide dose-response experiment showed that relative blood flow measured by DCS increased following treatment with 500- and 1000-mg / kg nicotinamide. The DCS and FM technique comparison showed that blood flow index measured by DCS was correlated with FM counts quantified by image analysis. The results of this study show that DCS is sensitive to nicotinamide-induced blood flow elevation in the murine left quadriceps femoris. Additionally, the results of the comparison were consistent with similar studies in higher-order animal models, suggesting that mouse models can be effectively employed to investigate the utility of DCS for various blood flow measurement applications.
Collapse
Affiliation(s)
- Ashley R. Proctor
- University of Rochester, Department of Biomedical Engineering, Rochester, New York, United States
| | - Gabriel A. Ramirez
- University of Rochester, Department of Biomedical Engineering, Rochester, New York, United States
| | - Songfeng Han
- University of Rochester, Institute of Optics, Rochester, New York, United States
| | - Ziping Liu
- University of Rochester, Department of Biomedical Engineering, Rochester, New York, United States
| | - Tracy M. Bubel
- University of Rochester, Center for Visual Science, Rochester, New York, United States
| | - Regine Choe
- University of Rochester, Department of Biomedical Engineering, Rochester, New York, United States
- University of Rochester, Department of Electrical and Computer Engineering, Rochester, New York, United States
- Address all correspondence to: Regine Choe, E-mail:
| |
Collapse
|
6
|
N-acetylcysteine effects on a murine model of chronic critical limb ischemia. Biochim Biophys Acta Mol Basis Dis 2018; 1864:454-463. [DOI: 10.1016/j.bbadis.2017.10.027] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2017] [Revised: 10/02/2017] [Accepted: 10/23/2017] [Indexed: 01/01/2023]
|
7
|
Shaul O, Fanrazi-Kahana M, Meitav O, Pinhasi GA, Abookasis D. Application of spatially modulated near-infrared structured light to study changes in optical properties of mouse brain tissue during heatstress. APPLIED OPTICS 2017; 56:8880-8886. [PMID: 29131171 DOI: 10.1364/ao.56.008880] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Accepted: 10/05/2017] [Indexed: 05/23/2023]
Abstract
Heat stress (HS) is a medical emergency defined by abnormally elevated body temperature that causes biochemical, physiological, and hematological changes. The goal of the present research was to detect variations in optical properties (absorption, reduced scattering, and refractive index coefficients) of mouse brain tissue during HS by using near-infrared (NIR) spatial light modulation. NIR spatial patterns with different spatial phases were used to differentiate the effects of tissue scattering from those of absorption. Decoupling optical scattering from absorption enabled the quantification of a tissue's chemical constituents (related to light absorption) and structural properties (related to light scattering). Technically, structured light patterns at low and high spatial frequencies of six wavelengths ranging between 690 and 970 nm were projected onto the mouse scalp surface while diffuse reflected light was recorded by a CCD camera positioned perpendicular to the mouse scalp. Concurrently to pattern projection, brain temperature was measured with a thermal camera positioned slightly off angle from the mouse head while core body temperature was monitored by thermocouple probe. Data analysis demonstrated variations from baseline measurements in a battery of intrinsic brain properties following HS.
Collapse
|
8
|
Pagliazzi M, Sekar SKV, Colombo L, Martinenghi E, Minnema J, Erdmann R, Contini D, Mora AD, Torricelli A, Pifferi A, Durduran T. Time domain diffuse correlation spectroscopy with a high coherence pulsed source: in vivo and phantom results. BIOMEDICAL OPTICS EXPRESS 2017; 8:5311-5325. [PMID: 29188122 PMCID: PMC5695972 DOI: 10.1364/boe.8.005311] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2017] [Revised: 10/12/2017] [Accepted: 10/24/2017] [Indexed: 05/18/2023]
Abstract
Diffuse correlation spectroscopy (DCS), combined with time-resolved reflectance spectroscopy (TRS) or frequency domain spectroscopy, aims at path length (i.e. depth) resolved, non-invasive and simultaneous assessment of tissue composition and blood flow. However, while TRS provides a path length resolved data, the standard DCS does not. Recently, a time domain DCS experiment showed path length resolved measurements for improved quantification with respect to classical DCS, but was limited to phantoms and small animal studies. Here, we demonstrate time domain DCS for in vivo studies on the adult forehead and the arm. We achieve path length resolved DCS by means of an actively mode-locked Ti:Sapphire laser that allows high coherence pulses, thus enabling adequate signal-to-noise ratio in relatively fast (~1 s) temporal resolution. This work paves the way to the translation of this approach to practical in vivo use.
Collapse
Affiliation(s)
- M. Pagliazzi
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
| | | | - L. Colombo
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | - E. Martinenghi
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | - J. Minnema
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
| | | | - D. Contini
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | - A. Dalla Mora
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | - A. Torricelli
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, 20133 Milano, Italy
| | - A. Pifferi
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, 20133 Milano, Italy
| | - T. Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), 08015 Barcelona, Spain
| |
Collapse
|
9
|
Han S, Proctor AR, Vella JB, Benoit DSW, Choe R. Non-invasive diffuse correlation tomography reveals spatial and temporal blood flow differences in murine bone grafting approaches. BIOMEDICAL OPTICS EXPRESS 2016; 7:3262-3279. [PMID: 27699097 PMCID: PMC5030009 DOI: 10.1364/boe.7.003262] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2016] [Revised: 07/30/2016] [Accepted: 07/31/2016] [Indexed: 05/16/2023]
Abstract
Longitudinal blood flow during murine bone graft healing was monitored non-invasively using diffuse correlation tomography. The system utilized spatially dense data from a scanning set-up, non-linear reconstruction, and micro-CT anatomical information. Weekly in vivo measurements were performed. Blood flow changes in autografts, which heal successfully, were localized to graft regions and consistent across mice. Poor healing allografts showed heterogeneous blood flow elevation and high inter-subject variabilities. Allografts with tissue-engineered periosteum showed responses intermediate to both autografts and allografts, consistent with healing observed. These findings suggest that spatiotemporal blood flow changes can be utilized to differentiate the degree of bone graft healing.
Collapse
Affiliation(s)
- Songfeng Han
- Institute of Optics, University of Rochester, Rochester, NY 14627, USA
| | - Ashley R. Proctor
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
| | - Joseph B. Vella
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
- Department of Orthopaedics and Center for Musculoskeletal Research, University of Rochester Medical Center, Rochester, NY 14642, USA
- Department of Otolaryngology-Head and Neck Surgery, University of Rochester Medical Center, Rochester, NY 14642, USA
| | - Danielle S. W. Benoit
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
- Department of Orthopaedics and Center for Musculoskeletal Research, University of Rochester Medical Center, Rochester, NY 14642, USA
- Department of Chemical Engineering, University of Rochester, Rochester, NY 14627, USA
- Department of Biomedical Genetics, University of Rochester Medical Center, Rochester, NY 14642, USA
| | - Regine Choe
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY 14627, USA
| |
Collapse
|
10
|
Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues. Nat Commun 2016; 7:12121. [PMID: 27358000 PMCID: PMC4931322 DOI: 10.1038/ncomms12121] [Citation(s) in RCA: 166] [Impact Index Per Article: 18.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Accepted: 05/31/2016] [Indexed: 01/09/2023] Open
Abstract
Light propagating in tissue attains a spectrum that varies with location due to wavelength-dependent fluence attenuation, an effect that causes spectral corruption. Spectral corruption has limited the quantification accuracy of optical and optoacoustic spectroscopic methods, and impeded the goal of imaging blood oxygen saturation (sO2) deep in tissues; a critical goal for the assessment of oxygenation in physiological processes and disease. Here we describe light fluence in the spectral domain and introduce eigenspectra multispectral optoacoustic tomography (eMSOT) to account for wavelength-dependent light attenuation, and estimate blood sO2 within deep tissue. We validate eMSOT in simulations, phantoms and animal measurements and spatially resolve sO2 in muscle and tumours, validating our measurements with histology data. eMSOT shows substantial sO2 accuracy enhancement over previous optoacoustic methods, potentially serving as a valuable tool for imaging tissue pathophysiology.
Collapse
|
11
|
Johansson JD, Mireles M, Morales-Dalmau J, Farzam P, Martínez-Lozano M, Casanovas O, Durduran T. Scanning, non-contact, hybrid broadband diffuse optical spectroscopy and diffuse correlation spectroscopy system. BIOMEDICAL OPTICS EXPRESS 2016; 7:481-98. [PMID: 26977357 PMCID: PMC4771466 DOI: 10.1364/boe.7.000481] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Revised: 12/19/2015] [Accepted: 01/13/2016] [Indexed: 05/24/2023]
Abstract
A scanning system for small animal imaging using non-contact, hybrid broadband diffuse optical spectroscopy (ncDOS) and diffuse correlation spectroscopy (ncDCS) is presented. The ncDOS uses a two-dimensional spectrophotometer retrieving broadband (610-900 nm) spectral information from up to fifty-seven source-detector distances between 2 and 5 mm. The ncDCS data is simultaneously acquired from four source-detector pairs. The sample is scanned in two dimensions while tracking variations in height. The system has been validated with liquid phantoms, demonstrated in vivo on a human fingertip during an arm cuff occlusion and on a group of mice with xenoimplanted renal cell carcinoma.
Collapse
Affiliation(s)
- Johannes D. Johansson
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Sciences and Technology, 08860, Castelldefels (Barcelona), Spain
| | - Miguel Mireles
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Sciences and Technology, 08860, Castelldefels (Barcelona), Spain
| | - Jordi Morales-Dalmau
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Sciences and Technology, 08860, Castelldefels (Barcelona), Spain
| | - Parisa Farzam
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Sciences and Technology, 08860, Castelldefels (Barcelona), Spain
| | - Mar Martínez-Lozano
- Program Against Cancer Therapeutic Resistance (ProCURE), Catalan Institute of Oncology, Bellvitge Biomedical Research Institute–IDIBELL, 08908, L’Hospitalet de Llobregat (Barcelona), Spain
| | - Oriol Casanovas
- Program Against Cancer Therapeutic Resistance (ProCURE), Catalan Institute of Oncology, Bellvitge Biomedical Research Institute–IDIBELL, 08908, L’Hospitalet de Llobregat (Barcelona), Spain
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Sciences and Technology, 08860, Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), 08015 Barcelona, Spain
| |
Collapse
|
12
|
Evaluation of the clinical relevance and limitations of current pre-clinical models of peripheral artery disease. Clin Sci (Lond) 2015; 130:127-50. [DOI: 10.1042/cs20150435] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Peripheral artery disease (PAD) has recognized treatment deficiencies requiring the discovery of novel interventions. This article describes current animal models of PAD and discusses their advantages and disadvantages. There is a need for models which more directly simulate the characteristics of human PAD, such as acute-on-chronic presentation, presence of established risk factors and impairment of physical activity.
Collapse
|
13
|
Han S, Hoffman MD, Proctor AR, Vella JB, Mannoh EA, Barber NE, Kim HJ, Jung KW, Benoit DSW, Choe R. Non-Invasive Monitoring of Temporal and Spatial Blood Flow during Bone Graft Healing Using Diffuse Correlation Spectroscopy. PLoS One 2015; 10:e0143891. [PMID: 26625352 PMCID: PMC4666601 DOI: 10.1371/journal.pone.0143891] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Accepted: 11/10/2015] [Indexed: 01/15/2023] Open
Abstract
Vascular infiltration and associated alterations in microvascular blood flow are critical for complete bone graft healing. Therefore, real-time, longitudinal measurement of blood flow has the potential to successfully predict graft healing outcomes. Herein, we non-invasively measure longitudinal blood flow changes in bone autografts and allografts using diffuse correlation spectroscopy in a murine femoral segmental defect model. Blood flow was measured at several positions proximal and distal to the graft site before implantation and every week post-implantation for a total of 9 weeks (autograft n = 7 and allograft n = 10). Measurements of the ipsilateral leg with the graft were compared with those of the intact contralateral control leg. Both autografts and allografts exhibited an initial increase in blood flow followed by a gradual return to baseline levels. Blood flow elevation lasted up to 2 weeks in autografts, but this duration varied from 2 to 6 weeks in allografts depending on the spatial location of the measurement. Intact contralateral control leg blood flow remained at baseline levels throughout the 9 weeks in the autograft group; however, in the allograft group, blood flow followed a similar trend to the graft leg. Blood flow difference between the graft and contralateral legs (ΔrBF), a parameter defined to estimate graft-specific changes, was elevated at 1–2 weeks for the autograft group, and at 2–4 weeks for the allograft group at the proximal and the central locations. However, distal to the graft, the allograft group exhibited significantly greater ΔrBF than the autograft group at 3 weeks post-surgery (p < 0.05). These spatial and temporal differences in blood flow supports established trends of delayed healing in allografts versus autografts.
Collapse
Affiliation(s)
- Songfeng Han
- Institute of Optics, University of Rochester, Rochester, New York, United States of America
| | - Michael D. Hoffman
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
- Department of Orthopaedics and Center for Musculoskeletal Research, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Ashley R. Proctor
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
| | - Joseph B. Vella
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
- Department of Orthopaedics and Center for Musculoskeletal Research, University of Rochester Medical Center, Rochester, New York, United States of America
- Department of Otolaryngology-Head and Neck Surgery, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Emmanuel A. Mannoh
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
| | - Nathaniel E. Barber
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
| | - Hyun Jin Kim
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
| | - Ki Won Jung
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
| | - Danielle S. W. Benoit
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
- Department of Orthopaedics and Center for Musculoskeletal Research, University of Rochester Medical Center, Rochester, New York, United States of America
- Department of Chemical Engineering, University of Rochester, Rochester, New York, United States of America
- Department of Biomedical Genetics, University of Rochester Medical Center, Rochester, New York, United States of America
| | - Regine Choe
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
- Department of Electrical and Computer Engineering, University of Rochester, New York, United States of America
- * E-mail:
| |
Collapse
|
14
|
Kogler AS, Bilfinger TV, Galler RM, Mesquita RC, Cutrone M, Schenkel SS, Yodh AG, Floyd TF. Fiber-optic Monitoring of Spinal Cord Hemodynamics in Experimental Aortic Occlusion. Anesthesiology 2015; 123:1362-73. [PMID: 26418696 PMCID: PMC4679520 DOI: 10.1097/aln.0000000000000883] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Spinal cord ischemia occurs frequently during thoracic aneurysm repair. Current methods based on electrophysiology techniques to detect ischemia are indirect, non-specific, and temporally slow. In this article, the authors report the testing of a spinal cord blood flow and oxygenation monitor, based on diffuse correlation and optical spectroscopies, during aortic occlusion in a sheep model. METHODS Testing was carried out in 16 Dorset sheep. Sensitivity in detecting spinal cord blood flow and oxygenation changes during aortic occlusion, pharmacologically induced hypotension and hypertension, and physiologically induced hypoxia/hypercarbia was assessed. Accuracy of the diffuse correlation spectroscopy measurements was determined via comparison with microsphere blood flow measurements. Precision was assessed through repeated measurements in response to pharmacologic interventions. RESULTS The fiber-optic probe can be placed percutaneously and is capable of continuously measuring spinal cord blood flow and oxygenation preoperatively, intraoperatively, and postoperatively. The device is sensitive to spinal cord blood flow and oxygenation changes associated with aortic occlusion, immediately detecting a decrease in blood flow (-65 ± 32%; n = 32) and blood oxygenation (-17 ± 13%, n = 11) in 100% of trials. Comparison of spinal cord blood flow measurements by the device with microsphere measurements led to a correlation of R = 0.49, P < 0.01, and the within-sheep coefficient of variation was 9.69%. Finally, diffuse correlation spectroscopy is temporally more sensitive to ischemic interventions than motor-evoked potentials. CONCLUSION The first-generation spinal fiber-optic monitoring device offers a novel and potentially important step forward in the monitoring of spinal cord ischemia.
Collapse
Affiliation(s)
- Angela S. Kogler
- Department of Anesthesiology, Stony Brook University Medical Center, Stony Brook, NY
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY
| | - Thomas V. Bilfinger
- Department of Surgery, Stony Brook University Medical Center, Stony Brook, NY
| | - Robert M. Galler
- Department of Neurological Surgery, Stony Brook University Medical Center, Stony Brook, NY
| | - Rickson C. Mesquita
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA
- Institute of Physics, University of Campinas, Campinas, SP, Brazil
| | - Michael Cutrone
- Department of Anesthesiology, Stony Brook University Medical Center, Stony Brook, NY
| | - Steven S. Schenkel
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA
| | - Arjun G. Yodh
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA
| | - Thomas F. Floyd
- Department of Anesthesiology, Stony Brook University Medical Center, Stony Brook, NY
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY
| |
Collapse
|
15
|
Majmundar AJ, Lee DSM, Skuli N, Mesquita RC, Kim MN, Yodh AG, Nguyen-McCarty M, Li B, Simon MC. HIF modulation of Wnt signaling regulates skeletal myogenesis in vivo. Development 2015; 142:2405-12. [PMID: 26153230 DOI: 10.1242/dev.123026] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Accepted: 06/01/2015] [Indexed: 12/19/2022]
Abstract
Deeper insight into the molecular pathways that orchestrate skeletal myogenesis should enhance our understanding of, and ability to treat, human skeletal muscle disease. It is now widely appreciated that nutrients, such as molecular oxygen (O2), modulate skeletal muscle formation. During early stages of development and regeneration, skeletal muscle progenitors reside in low O2 environments before local blood vessels and differentiated muscle form. Moreover, low O2 availability (hypoxia) impedes progenitor-dependent myogenesis in vitro through multiple mechanisms, including activation of hypoxia inducible factor 1α (HIF1α). However, whether HIF1α regulates skeletal myogenesis in vivo is not known. Here, we explored the role of HIF1α during murine skeletal muscle development and regeneration. Our results demonstrate that HIF1α is dispensable during embryonic and fetal myogenesis. However, HIF1α negatively regulates adult muscle regeneration after ischemic injury, implying that it coordinates adult myogenesis with nutrient availability in vivo. Analyses of Hif1a mutant muscle and Hif1a-depleted muscle progenitors further suggest that HIF1α represses myogenesis through inhibition of canonical Wnt signaling. Our data provide the first evidence that HIF1α regulates skeletal myogenesis in vivo and establish a novel link between HIF and Wnt signaling in this context.
Collapse
Affiliation(s)
- Amar J Majmundar
- Abramson Family Cancer Research Institute, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA 19104, USA Department of Cell and Developmental Biology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - David S M Lee
- Abramson Family Cancer Research Institute, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA 19104, USA Howard Hughes Medical Institute, 421 Curie Blvd., Philadelphia, PA 19104, USA
| | - Nicolas Skuli
- Institut National de la Santé et de la Recherche Médicale Unité 1037, Institut Claudius Regaud, Toulouse 31052, France
| | - Rickson C Mesquita
- Department of Physics & Astronomy, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Meeri N Kim
- Department of Physics & Astronomy, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Arjun G Yodh
- Department of Physics & Astronomy, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Michelle Nguyen-McCarty
- Abramson Family Cancer Research Institute, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA 19104, USA Department of Cell and Developmental Biology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Bo Li
- Program in Cancer Biology, Affiliated Guangzhou Women and Children's Hospital, Zhongshan School of Medicine, Sun Yat-Sen University, Guangzhou 510080, China Department of Biochemistry, Zhongshan School of Medicine, Sun Yat-Sen University, Guangzhou 510080, China
| | - M Celeste Simon
- Abramson Family Cancer Research Institute, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA 19104, USA Department of Cell and Developmental Biology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA 19104, USA Howard Hughes Medical Institute, 421 Curie Blvd., Philadelphia, PA 19104, USA
| |
Collapse
|
16
|
Han S, Johansson J, Mireles M, Proctor AR, Hoffman MD, Vella JB, Benoit DSW, Durduran T, Choe R. Non-contact scanning diffuse correlation tomography system for three-dimensional blood flow imaging in a murine bone graft model. BIOMEDICAL OPTICS EXPRESS 2015; 6. [PMID: 26203392 PMCID: PMC4505720 DOI: 10.1364/boe.6.002695] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
A non-contact galvanometer-based optical scanning system for diffuse correlation tomography was developed for monitoring bone graft healing in a murine femur model. A linear image reconstruction algorithm for diffuse correlation tomography was tested using finite-element method based simulated data and experimental data from a femur or a tube suspended in a homogeneous liquid phantom. Finally, the non-contact system was utilized to monitor in vivo blood flow changes prior to and one week after bone graft transplantation within murine femurs. Localized blood flow changes were observed in three mice, demonstrating a potential for quantification of longitudinal blood flow associated with bone graft healing.
Collapse
Affiliation(s)
- Songfeng Han
- Institute of Optics, University of Rochester, Rochester, NY 14627, USA
| | - Johannes Johansson
- ICFO- Institut de Ciències Fotòniques, 08860, Castelldefels (Barcelona), Spain
| | - Miguel Mireles
- ICFO- Institut de Ciències Fotòniques, 08860, Castelldefels (Barcelona), Spain
| | - Ashley R. Proctor
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
| | - Michael D. Hoffman
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
- Department of Orthopaedics and Center for Musculoskeletal Research, University of Rochester Medical Center, Rochester, NY 14642, USA
| | - Joseph B. Vella
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
- Department of Orthopaedics and Center for Musculoskeletal Research, University of Rochester Medical Center, Rochester, NY 14642, USA
- Department of Otolaryngology-Head and Neck Surgery, University of Rochester Medical Center, Rochester, NY 14642, USA
| | - Danielle S. W. Benoit
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
- Department of Orthopaedics and Center for Musculoskeletal Research, University of Rochester Medical Center, Rochester, NY 14642, USA
- Department of Chemical Engineering, University of Rochester, Rochester, NY 14627, USA
- Department of Biomedical Genetics, University of Rochester Medical Center, Rochester, NY 14642, USA
| | - Turgut Durduran
- ICFO- Institut de Ciències Fotòniques, 08860, Castelldefels (Barcelona), Spain
| | - Regine Choe
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY 14627, USA
| |
Collapse
|
17
|
Continuous optical monitoring of cerebral hemodynamics during head-of-bed manipulation in brain-injured adults. Neurocrit Care 2015; 20:443-53. [PMID: 23653267 DOI: 10.1007/s12028-013-9849-7] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
INTRODUCTION Head-of-bed manipulation is commonly performed in the neurocritical care unit to optimize cerebral blood flow (CBF), but its effects on CBF are rarely measured. This pilot study employs a novel, non-invasive instrument combining two techniques, diffuse correlation spectroscopy (DCS) for measurement of CBF and near-infrared spectroscopy (NIRS) for measurement of cerebral oxy- and deoxy-hemoglobin concentrations, to monitor patients during head-of-bed lowering. METHODS Ten brain-injured patients and ten control subjects were monitored continuously with DCS and NIRS while the head-of-bed was positioned first at 30° and then at 0°. Relative CBF (rCBF) and concurrent changes in oxy- (ΔHbO2), deoxy- (ΔHb), and total-hemoglobin concentrations (ΔTHC) from left/right frontal cortices were monitored for 5 min at each position. Patient and control response differences were assessed. RESULTS rCBF, ΔHbO2, and ΔTHC responses to head lowering differed significantly between brain-injured patients and healthy controls (P < 0.02). For patients, rCBF changes were heterogeneous, with no net change observed in the group average (0.3 ± 28.2 %, P = 0.938). rCBF increased in controls (18.6 ± 9.4 %, P < 0.001). ΔHbO2, ΔHb, and ΔTHC increased with head lowering in both groups, but to a larger degree in brain-injured patients. rCBF correlated moderately with changes in cerebral perfusion pressure (R = 0.40, P < 0.001), but not intracranial pressure. CONCLUSION DCS/NIRS detected differences in CBF and oxygenation responses of brain-injured patients versus controls during head-of-bed manipulation. This pilot study supports the feasibility of continuous bedside measurement of cerebrovascular hemodynamics with DCS/NIRS and provides the rationale for further investigation in larger cohorts.
Collapse
|
18
|
Baker WB, Parthasarathy AB, Busch DR, Mesquita RC, Greenberg JH, Yodh AG. Modified Beer-Lambert law for blood flow. BIOMEDICAL OPTICS EXPRESS 2014; 5:4053-75. [PMID: 25426330 PMCID: PMC4242038 DOI: 10.1364/boe.5.004053] [Citation(s) in RCA: 154] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2014] [Revised: 10/14/2014] [Accepted: 10/15/2014] [Indexed: 05/18/2023]
Abstract
We develop and validate a Modified Beer-Lambert law for blood flow based on diffuse correlation spectroscopy (DCS) measurements. The new formulation enables blood flow monitoring from temporal intensity autocorrelation function data taken at single or multiple delay-times. Consequentially, the speed of the optical blood flow measurement can be substantially increased. The scheme facilitates blood flow monitoring of highly scattering tissues in geometries wherein light propagation is diffusive or non-diffusive, and it is particularly well-suited for utilization with pressure measurement paradigms that employ differential flow signals to reduce contributions of superficial tissues.
Collapse
Affiliation(s)
- Wesley B. Baker
- Dept. Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104,
USA
| | | | - David R. Busch
- Dept. Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104,
USA
- Div. of Neurology, Children’s Hospital of Philadelphia, Philadelphia, PA 19104,
USA
| | - Rickson C. Mesquita
- Institute of Physics, University of Campinas, Campinas, SP 13083-859,
Brazil
| | - Joel H. Greenberg
- Dept. Neurology, University of Pennsylvania, Philadelphia, PA 19104,
USA
| | - A. G. Yodh
- Dept. Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104,
USA
| |
Collapse
|
19
|
Torricelli A, Contini D, Mora AD, Pifferi A, Re R, Zucchelli L, Caffini M, Farina A, Spinelli L. Neurophotonics: non-invasive optical techniques for monitoring brain functions. FUNCTIONAL NEUROLOGY 2014; 29:223-30. [PMID: 25764252 PMCID: PMC4370435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The aim of this review is to present the state of the art of neurophotonics, a recently founded discipline lying at the interface between optics and neuroscience. While neurophotonics also includes invasive techniques for animal studies, in this review we focus only on the non-invasive methods that use near infrared light to probe functional activity in the brain, namely the fast optical signal, diffuse correlation spectroscopy, and functional near infrared spectroscopy methods. We also present an overview of the physical principles of light propagation in biological tissues, and of the main physiological sources of signal. Finally, we discuss the open issues in models, instrumentation, data analysis and clinical approaches.
Collapse
Affiliation(s)
| | - Davide Contini
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
| | | | | | - Rebecca Re
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
| | | | - Matteo Caffini
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Andrea Farina
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale per le Ricerche, Milan, Italy
| | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale per le Ricerche, Milan, Italy
| |
Collapse
|
20
|
Farzam P, Lindner C, Weigel UM, Suarez M, Urbano-Ispizua A, Durduran T. Noninvasive characterization of the healthy human manubrium using diffuse optical spectroscopies. Physiol Meas 2014; 35:1469-91. [DOI: 10.1088/0967-3334/35/7/1469] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
21
|
Zhang X, Cheng R, Rowe D, Sethu P, Daugherty A, Yu G, Shin HY. Shear-sensitive regulation of neutrophil flow behavior and its potential impact on microvascular blood flow dysregulation in hypercholesterolemia. Arterioscler Thromb Vasc Biol 2014; 34:587-93. [PMID: 24458712 DOI: 10.1161/atvbaha.113.302868] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVE Shear stress-induced pseudopod retraction is an anti-inflammatory measure that minimizes neutrophil activity and is regulated by membrane cholesterol. We tested the hypothesis that a hypercholesterolemic impairment of shear mechanotransduction alters the neutrophil flow behavior leading to microvascular dysfunction. APPROACH AND RESULTS We examined the shear effects on the flow behavior of human leukocytes. When subjected to shearing during cone-plate viscometry, leukocyte suspensions exhibited parallel time-dependent reductions in viscosity and pseudopod activity. Shear-induced reductions in suspension viscosity were attenuated by membrane cholesterol enrichment. We also showed that enhanced pseudopod activity of leukocyte suspensions in 10% hematocrit significantly (P<0.05) raised the flow resistance of microvascular mimics. These results implicate an impaired neutrophil pseudopod retraction response to shear in hypercholesterolemic microvascular dysfunction. We confirmed this using near-infrared diffuse correlation spectroscopy to assess skeletal muscle blood flow regulation in the hindlimbs of mice subjected to reactive hyperemia. Using a custom protocol for the mouse, we extrapolated an adjusted peak flow and time to adjusted peak flow to quantify the early phase of the blood flow recovery response during reactive hyperemia when shear mechanobiology likely has a maximal impact. Compared with mice on normal diet, hypercholesterolemic mice exhibited significantly (P<0.05) reduced adjusted peak flow and prolonged time to adjusted peak flow which correlated (r=0.4 and r=-0.3, respectively) with neutrophil shear responsiveness and were abrogated by neutropenia. CONCLUSIONS These results provide the first evidence that the neutrophils contribute to tissue blood flow autoregulation. Moreover, a deficit in the neutrophil responsiveness to shear may be a feature of hypercholesterolemia-related microvascular dysfunction.
Collapse
Affiliation(s)
- Xiaoyan Zhang
- From the Department of Biomedical Engineering, University of Kentucky, Lexington (X.Z., R.C., D.R., G.Y., H.Y.S); Math, Science, and Technology Center, Paul L. Dunbar High School, Lexington, KY (D.R.); Division of Cardiovascular Disease, University of Alabama at Birmingham (P.S.); and Saha Cardiovascular Research Center, University of Kentucky, Lexington (A.D.)
| | | | | | | | | | | | | |
Collapse
|
22
|
Durduran T, Yodh AG. Diffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement. Neuroimage 2014; 85 Pt 1:51-63. [PMID: 23770408 PMCID: PMC3991554 DOI: 10.1016/j.neuroimage.2013.06.017] [Citation(s) in RCA: 321] [Impact Index Per Article: 29.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2013] [Revised: 05/10/2013] [Accepted: 06/06/2013] [Indexed: 12/25/2022] Open
Abstract
Diffuse correlation spectroscopy (DCS) uses the temporal fluctuations of near-infrared (NIR) light to measure cerebral blood flow (CBF) non-invasively. Here, we provide a brief history of DCS applications in the brain with an emphasis on the underlying physical ideas, common instrumentation and validation. Then we describe recent clinical research that employs DCS-measured CBF as a biomarker of patient well-being, and as an indicator of hemodynamic and metabolic responses to functional stimuli.
Collapse
Affiliation(s)
- Turgut Durduran
- ICFO- Institut de Ciències Fotòniques, Mediterranean Technology Park, 08860 Castelldefels, Barcelona, Spain.
| | | |
Collapse
|
23
|
Mesquita RC, D’Souza A, Bilfinger TV, Galler RM, Emanuel A, Schenkel SS, Yodh AG, Floyd TF. Optical monitoring and detection of spinal cord ischemia. PLoS One 2013; 8:e83370. [PMID: 24358279 PMCID: PMC3865183 DOI: 10.1371/journal.pone.0083370] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2013] [Accepted: 11/01/2013] [Indexed: 12/14/2022] Open
Abstract
Spinal cord ischemia can lead to paralysis or paraparesis, but if detected early it may be amenable to treatment. Current methods use evoked potentials for detection of spinal cord ischemia, a decades old technology whose warning signs are indirect and significantly delayed from the onset of ischemia. Here we introduce and demonstrate a prototype fiber optic device that directly measures spinal cord blood flow and oxygenation. This technical advance in neurological monitoring promises a new standard of care for detection of spinal cord ischemia and the opportunity for early intervention. We demonstrate the probe in an adult Dorset sheep model. Both open and percutaneous approaches were evaluated during pharmacologic, physiological, and mechanical interventions designed to induce variations in spinal cord blood flow and oxygenation. The induced variations were rapidly and reproducibly detected, demonstrating direct measurement of spinal cord ischemia in real-time. In the future, this form of hemodynamic spinal cord diagnosis could significantly improve monitoring and management in a broad range of patients, including those undergoing thoracic and abdominal aortic revascularization, spine stabilization procedures for scoliosis and trauma, spinal cord tumor resection, and those requiring management of spinal cord injury in intensive care settings.
Collapse
Affiliation(s)
- Rickson C. Mesquita
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
- Institute of Physics, University of Campinas, Campinas, São Paulo, Brazil
| | - Angela D’Souza
- Department of Anesthesiology, Stony Brook University Medical Center, Stony Brook, New York, United States of America
- Department of Biomedical Engineering, Stony Brook University Medical Center, Stony Brook, New York, United States of America
| | - Thomas V. Bilfinger
- Department of Surgery, Stony Brook University Medical Center, Stony Brook, New York, United States of America
| | - Robert M. Galler
- Department of Neurosurgery, Stony Brook University Medical Center, Stony Brook, New York, United States of America
| | - Asher Emanuel
- Department of Anesthesiology, Stony Brook University Medical Center, Stony Brook, New York, United States of America
| | - Steven S. Schenkel
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Arjun G. Yodh
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Thomas F. Floyd
- Department of Anesthesiology, Stony Brook University Medical Center, Stony Brook, New York, United States of America
- Department of Biomedical Engineering, Stony Brook University Medical Center, Stony Brook, New York, United States of America
- * E-mail:
| |
Collapse
|
24
|
Cheng R, Zhang X, Daugherty A, Shin H, Yu G. Noninvasive quantification of postocclusive reactive hyperemia in mouse thigh muscle by near-infrared diffuse correlation spectroscopy. APPLIED OPTICS 2013; 52:7324-30. [PMID: 24216586 DOI: 10.1364/ao.52.007324] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Many vasculature-related diseases affecting skeletal muscle function have been studied in mouse models. Noninvasive quantification of muscle blood flow responses during postocclusive reactive hyperemia (PORH) is often used to evaluate vascular function in human skeletal muscles. However, blood flow measurements during PORH in small skeletal muscles of mice are rare due to the lack of appropriate technologies coupled with the challenge of measurement setup resulting from the lack of large enough test sites. In this study, we explored adapting diffuse correlation spectroscopy (DCS) for noninvasive measurement of the relative changes of blood flow (rBF) in mouse thigh muscles during PORH. A small fiber-optic probe was designed and glued on the mouse thigh to reduce the motion artifact induced by the occlusion procedure. Arterial occlusion was created by tying a polyvinyl chloride (PVC) tube around the mouse thigh while the muscle rBF was continuously monitored by DCS to ensure the success of the occlusion. After 5 min, the occlusion was rapidly released by severing the PVC tube using a cautery pen. Typical rBF responses during PORH were observed in all mice (n=7), which are consistent with those observed by arterial-spin-labeled magnetic resonance imaging (ASL-MRI) as reported in the literature. On average, rBF values from DCS during occlusion were lower than 10% (3.1±2.2%) of the baseline values (assigning 100%), indicating the success of arterial occlusion in all mice. Peak values of rBF during PORH measured by the DCS (357.6±36.3%) and ASL-MRI (387.5±150.0%) were also similar whereas the values of time-to-peak (the time duration from the end of occlusion to the peak rBF) were quite different (112.6±35.0 s versus 48.0±27.0 s). Simultaneous measurements by these two techniques are needed to identify the factors that may cause such discrepancy. This study highlights the utility of DCS technology to quantitatively evaluate tissue blood flow responses during PORH in mouse skeletal muscles. DCS holds promise as valuable tool to assess blood flow regulation in mouse models with a variety of vascular diseases (e.g., hypercholesterolemia, diabetes, peripheral artery disease).
Collapse
|
25
|
Poole KM, Tucker-Schwartz JM, Sit WW, Walsh AJ, Duvall CL, Skala MC. Quantitative optical imaging of vascular response in vivo in a model of peripheral arterial disease. Am J Physiol Heart Circ Physiol 2013; 305:H1168-80. [PMID: 23955718 PMCID: PMC3798791 DOI: 10.1152/ajpheart.00362.2013] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2013] [Accepted: 08/13/2013] [Indexed: 12/20/2022]
Abstract
The mouse hind limb ischemia (HLI) model is well established for studying collateral vessel formation and testing therapies for peripheral arterial disease, but there is a lack of quantitative techniques for intravitally analyzing blood vessel structure and function. To address this need, non-invasive, quantitative optical imaging techniques were developed to assess the time-course of recovery in the mouse HLI model. Hyperspectral imaging and optical coherence tomography (OCT) were used to non-invasively image hemoglobin oxygen saturation and microvessel morphology plus blood flow, respectively, in the anesthetized mouse after induction of HLI. Hyperspectral imaging detected significant increases in hemoglobin saturation in the ischemic paw as early as 3 days after femoral artery ligation (P < 0.01), and significant increases in distal blood flow were first detected with OCT 14 days postsurgery (P < 0.01). Intravital OCT images of the adductor muscle vasculature revealed corkscrew collateral vessels characteristic of the arteriogenic response to HLI. The hyperspectral imaging and OCT data significantly correlated with each other and with laser Doppler perfusion imaging (LDPI) and tissue oxygenation sensor data (P < 0.01). However, OCT measurements acquired depth-resolved information and revealed more sustained flow deficits following surgery that may be masked by more superficial measurements (LDPI, hyperspectral imaging). Therefore, intravital OCT may provide a robust biomarker for the late stages of ischemic limb recovery. This work validates non-invasive acquisition of both functional and morphological data with hyperspectral imaging and OCT. Together, these techniques provide cardiovascular researchers an unprecedented and comprehensive view of the temporal dynamics of HLI recovery in living mice.
Collapse
Affiliation(s)
- Kristin M Poole
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee
| | | | | | | | | | | |
Collapse
|
26
|
Ouma GO, Rodriguez E, Muthumani K, Weiner DB, Wilensky RL, Mohler ER. In vivo electroporation of constitutively expressed HIF-1α plasmid DNA improves neovascularization in a mouse model of limb ischemia. J Vasc Surg 2013; 59:786-93. [PMID: 23850058 DOI: 10.1016/j.jvs.2013.04.043] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2013] [Revised: 04/09/2013] [Accepted: 04/17/2013] [Indexed: 01/09/2023]
Abstract
OBJECTIVE Hypoxia-inducible factor-1 alpha (HIF-1α) is a transcription factor that stimulates angiogenesis during tissue ischemia. In vivo electroporation (EP) enhances tissue DNA transfection. We hypothesized that in vivo EP of plasmid DNA encoding a constitutively expressed HIF-1α gene enhances neovascularization compared with intramuscular (IM) injection alone. METHODS Left femoral artery ligation was performed in mice assigned to three groups: (1) HIF-EP (n = 13); (2) HIF-IM (n = 14); and (3) empty plasmid (pVAX)-EP (n = 12). A single dose of HIF-1α or pVAX DNA (20 μL of 5 μg/μL each) was injected into the ischemic adductor muscle followed by EP (groups one and three). Mice in group two received IM injection of HIF-1α plasmid DNA alone. From preligation to days 0, 3, 7, 14, and 21 postligation, limb perfusion recovery quantified by laser Doppler perfusion imager, limb function, and limb necrosis were measured. On day 21, the surviving mice (4-5 per group) were sacrificed and adductor muscle tissues stained for necrosis using hematoxylin and eosin, capillary density (anti-CD31 antibodies), and collateral vessels via anti-α-smooth muscle actin antibodies. RESULTS In vivo EP of HIF-1α DNA significantly improved limb perfusion (HIF-EP: 1.03 ± 0.15 vs HIF-IM: 0.78 ± 0.064; P < .05, vs pVAX-EP: 0.41 ± 0.019; P < .001), limb functional recovery (HIF-EP: 3.5 ± 0.58 vs HIF-IM, 2.4 ± 1.14; P < .05, vs pVAX-EP: 2.4 ± 1.14; P < .001), and limb autoamputation on day 21 (HIF-EP: 77% ± 12% vs HIF-IM: 43% ± 14%; P < .05 vs pVAX-EP: 17% ± 11%; P < .01). Adductor muscle tissue necrosis decreased (HIF-EP: 20.7% ± 1.75% vs HIF-IM: 44% ± 3.73; P < .001, vs pVAX-EP: 60.05% ± 2.17%; P < .0001), capillary density increased (HIF-EP: 96.83 ± 5.72 vessels/high-powered field [hpf] vs HIF-IM: 62.87 ± 2.0 vessels/hpf; P < .001, vs pVAX-EP: 39.37 ± 2.76 vessels/hpf; P < .0001), collateral vessel formation increased (HI-EP: 76.33 ± 1.94 vessels/hpf vs HIF-IM: 37.5 ± 1.56 vessels/hpf; P < .0001, vs pVAX-EP: 18.5 ± 1.34 vessels/hpf; P < .00001), and the vessels were larger (HIF-EP: 15,521.67 ± 1298.16 μm(2) vs HIF-IM: 7788.87 ± 392.04 μm(2); P < .001 vs pVAX-EP: 4640.25 ± 614.01 μm(2); P < .0001). CONCLUSIONS In vivo EP-mediated delivery of HIF-1α plasmid DNA improves neovascularization in a mouse model of limb ischemia and is a potentially suitable nonviral, noninvasive intervention to facilitate therapeutic angiogenesis in critical limb ischemia.
Collapse
Affiliation(s)
- Geoffrey O Ouma
- Department of Medicine, Cardiovascular Division, Vascular Medicine Section, Perelman School of Medicine at the University of Pennsylvania and University of Pennsylvania Health System, Philadelphia, Pa.
| | - Eduardo Rodriguez
- Department of Surgery, Perelman School of Medicine at the University of Pennsylvania and University of Pennsylvania Health System, Philadelphia, Pa
| | - Karuppiah Muthumani
- Department of Pathology and Laboratory Medicine, Perelman School of Medicine at the University of Pennsylvania and University of Pennsylvania Health System, Philadelphia, Pa
| | - David B Weiner
- Department of Pathology and Laboratory Medicine, Perelman School of Medicine at the University of Pennsylvania and University of Pennsylvania Health System, Philadelphia, Pa
| | - Robert L Wilensky
- Cardiovascular Division, Hospitial of the University of Pennsylvania and Cardiovascular Institute, Perelman School of Medicine at the University of Pennsylvania and University of Pennsylvania Health System, Philadelphia, Pa
| | - Emile R Mohler
- Department of Medicine, Cardiovascular Division, Vascular Medicine Section, Perelman School of Medicine at the University of Pennsylvania and University of Pennsylvania Health System, Philadelphia, Pa
| |
Collapse
|
27
|
Mesquita RC, Schenkel SS, Minkoff DL, Lu X, Favilla CG, Vora PM, Busch DR, Chandra M, Greenberg JH, Detre JA, Yodh AG. Influence of probe pressure on the diffuse correlation spectroscopy blood flow signal: extra-cerebral contributions. BIOMEDICAL OPTICS EXPRESS 2013; 4:978-94. [PMID: 23847725 PMCID: PMC3704102 DOI: 10.1364/boe.4.000978] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2013] [Revised: 05/13/2013] [Accepted: 05/14/2013] [Indexed: 05/03/2023]
Abstract
A pilot study explores relative contributions of extra-cerebral (scalp/skull) versus brain (cerebral) tissues to the blood flow index determined by diffuse correlation spectroscopy (DCS). Microvascular DCS flow measurements were made on the head during baseline and breath-holding/hyperventilation tasks, both with and without pressure. Baseline (resting) data enabled estimation of extra-cerebral flow signals and their pressure dependencies. A simple two-component model was used to derive baseline and activated cerebral blood flow (CBF) signals, and the DCS flow indices were also cross-correlated with concurrent Transcranial Doppler Ultrasound (TCD) blood velocity measurements. The study suggests new pressure-dependent experimental paradigms for elucidation of blood flow contributions from extra-cerebral and cerebral tissues.
Collapse
Affiliation(s)
- Rickson C. Mesquita
- Department of Physics & Astronomy, University of Pennsylvania, 3231 Walnut St., Philadelphia, PA 19104, USA
- Institute of Physics, University of Campinas, 777 Sergio Buarque de Holanda St., Campinas, SP 13083-859, Brazil
| | - Steven S. Schenkel
- Department of Physics & Astronomy, University of Pennsylvania, 3231 Walnut St., Philadelphia, PA 19104, USA
| | - David L. Minkoff
- Department of Physics & Astronomy, University of Pennsylvania, 3231 Walnut St., Philadelphia, PA 19104, USA
| | - Xiangping Lu
- Department of Neurology, University of Pennsylvania, 3400 Spruce St., Philadelphia, PA 19104, USA
| | - Christopher G. Favilla
- Department of Neurology, University of Pennsylvania, 3400 Spruce St., Philadelphia, PA 19104, USA
| | - Patrick M. Vora
- Department of Physics & Astronomy, University of Pennsylvania, 3231 Walnut St., Philadelphia, PA 19104, USA
| | - David R. Busch
- Department of Physics & Astronomy, University of Pennsylvania, 3231 Walnut St., Philadelphia, PA 19104, USA
- Department of Pediatrics, Division of Neurology, Children’s Hospital of Philadelphia, 34th St. & Civic Center Blvd., Philadelphia, PA 19104, USA
| | - Malavika Chandra
- Department of Physics & Astronomy, University of Pennsylvania, 3231 Walnut St., Philadelphia, PA 19104, USA
| | - Joel H. Greenberg
- Department of Neurology, University of Pennsylvania, 3400 Spruce St., Philadelphia, PA 19104, USA
| | - John A. Detre
- Department of Neurology, University of Pennsylvania, 3400 Spruce St., Philadelphia, PA 19104, USA
- Department of Radiology, University of Pennsylvania, 3400 Spruce St., Philadelphia, PA 19104, USA
| | - A. G. Yodh
- Department of Physics & Astronomy, University of Pennsylvania, 3231 Walnut St., Philadelphia, PA 19104, USA
| |
Collapse
|
28
|
Mesquita RC, Putt M, Chandra M, Yu G, Xing X, Han SW, Lech G, Shang Y, Durduran T, Zhou C, Yodh AG, Mohler ER. Diffuse optical characterization of an exercising patient group with peripheral artery disease. JOURNAL OF BIOMEDICAL OPTICS 2013; 18:57007. [PMID: 23708193 PMCID: PMC3662991 DOI: 10.1117/1.jbo.18.5.057007] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2012] [Revised: 04/07/2013] [Accepted: 04/19/2013] [Indexed: 05/19/2023]
Abstract
Peripheral artery disease (PAD) is a common condition with high morbidity. While measurement of tissue oxygen saturation (S(t)O(2)) has been demonstrated, this is the first study to assess both S(t)O(2) and relative blood flow (rBF) in the extremities of PAD patients. Diffuse optics is employed to measure hemodynamic response to treadmill and pedal exercises in 31 healthy controls and 26 patients. For S(t)O(2), mild and moderate/severe PAD groups show pronounced differences compared with controls. Pre-exercise mean S(t)O(2) is lower in PAD groups by 9.3% to 10.6% compared with means of 63.5% to 66.2% in controls. For pedal, relative rate of return of S(t)O(2) to baseline is more rapid in controls (p < 0.05). Patterns of rBF also differ among groups. After both exercises, rBF tend to occur at depressed levels among severe PAD patients compared with healthy (p < 0.05); post-treadmill, rBF tend to occur at elevated levels among healthy compared with severe PAD patients (p < 0.05). Additionally, relative rate of return to baseline S(t)O(2) is more rapid among subjects with reduced levels of depression in rBF (p = 0.041), even after adjustment for ankle brachial index. This suggests a physiologic connection between rBF and oxygenation that can be measured using diffuse optics, and potentially employed as an evaluative tool in further studies.
Collapse
Affiliation(s)
- Rickson C Mesquita
- University of Pennsylvania, Department of Physics and Astronomy, Philadelphia, PA 19104, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Joshi RV, Nelson CE, Poole KM, Skala MC, Duvall CL. Dual pH- and temperature-responsive microparticles for protein delivery to ischemic tissues. Acta Biomater 2013; 9:6526-34. [PMID: 23402764 PMCID: PMC3702271 DOI: 10.1016/j.actbio.2013.01.041] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2012] [Revised: 01/10/2013] [Accepted: 01/29/2013] [Indexed: 01/10/2023]
Abstract
Injectable "smart" microspheres that are sensitive to both temperature and pH have been fabricated and tested for controlled delivery of therapeutic proteins to ischemic skeletal muscle. A library of copolymers composed of N-isopropyl acrylamide (NIPAAm), propyl acrylic acid (PAA), and butyl acrylate (BA) was used to fabricate microspheres using a double emulsion method, and an optimal formulation made from copolymers composed of 57 mol.% NIPAAm, 18 mol.% PAA and 25 mol.% BA copolymers was identified. At 37°C and pH representative of ischemic muscle (i.e. pH 5.2-7.2), these microspheres produced sustained, diffusion-controlled release, and at normal, physiological pH (i.e. pH 7.4), they underwent dissolution and rapid clearance. Delivery of fibroblast growth factor 2 was used to confirm that protein bioactivity was retained following microsphere encapsulation/release based on a dose-dependent increase in NIH3T3 fibroblast proliferation in vitro. Microsphere-loaded or free Cy5.5-labeled albumin was injected into ischemic and control gastrocnemii of mice following unilateral induction of hind limb ischemia to model peripheral arterial disease. In the ischemic limb at days 3.5 and 7, there was higher local retention of the protein delivered via microspheres relative to injected free protein (p<0.05). However, clearance of protein delivered via microspheres was equivalent to free protein at later time points that correspond to ischemic recovery in this model. Finally, histological analysis of the gastrocnemius revealed that the polymeric microspheres did not produce any microscopic signs of toxicity near the injection site. These combined results suggest that the pH- and temperature-responsive microspheres presented herein are a promising technological platform for controlled protein delivery to ischemic tissue.
Collapse
|
30
|
Dong L, He L, Lin Y, Shang Y, Yu G. Simultaneously extracting multiple parameters via fitting one single autocorrelation function curve in diffuse correlation spectroscopy. IEEE Trans Biomed Eng 2012. [PMID: 23193446 DOI: 10.1109/tbme.2012.2226885] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Near-infrared diffuse correlation spectroscopy (DCS) has recently been employed for noninvasive acquisition of blood flow information in deep tissues. Based on the established correlation diffusion equation, the light intensity autocorrelation function detected by DCS is determined by a blood flow index αD(B), tissue absorption coefficient μ(a), reduced scattering coefficient μ'(s), and a coherence factor β. This study is designed to investigate the possibility of extracting multiple parameters such as μ(a), μ'(s), β, and αD(B) through fitting one single autocorrelation function curve and evaluate the performance of different fitting methods. For this purpose, computer simulations, tissue-like phantom experiments, and in vivo tissue measurements were utilized. The results suggest that it is impractical to simultaneously fit αD(B) and μ(a) or αD(B) and μ'(s) from one single autocorrelation function curve due to the large crosstalk between these paired parameters. However, simultaneously fitting β and αD(B) is feasible and generates more accurate estimation with smaller standard deviation compared to the conventional two-step fitting method (i.e., first calculating β and then fitting αD(B)). The outcomes from this study provide a crucial guidance for DCS data analysis.
Collapse
Affiliation(s)
- Lixin Dong
- Center for Biomedical Engineering, University of Kentucky College of Engineering, Lexington, KY 40506, USA.
| | | | | | | | | |
Collapse
|
31
|
Abstract
The vascular network delivers oxygen (O(2)) and nutrients to all cells within the body. It is therefore not surprising that O(2) availability serves as a primary regulator of this complex organ. Most transcriptional responses to low O(2) are mediated by hypoxia-inducible factors (HIFs), highly conserved transcription factors that control the expression of numerous angiogenic, metabolic, and cell cycle genes. Accordingly, the HIF pathway is currently viewed as a master regulator of angiogenesis. HIF modulation could provide therapeutic benefit for a wide array of pathologies, including cancer, ischemic heart disease, peripheral artery disease, wound healing, and neovascular eye diseases. Hypoxia promotes vessel growth by upregulating multiple pro-angiogenic pathways that mediate key aspects of endothelial, stromal, and vascular support cell biology. Interestingly, recent studies show that hypoxia influences additional aspects of angiogenesis, including vessel patterning, maturation, and function. Through extensive research, the integral role of hypoxia and HIF signaling in human disease is becoming increasingly clear. Consequently, a thorough understanding of how hypoxia regulates angiogenesis through an ever-expanding number of pathways in multiple cell types will be essential for the identification of new therapeutic targets and modalities.
Collapse
Affiliation(s)
- Bryan L Krock
- Abramson Family Cancer Research Institute, University of Pennsylvania, Philadelphia, PA, USA
| | | | | |
Collapse
|
32
|
Skuli N, Majmundar AJ, Krock BL, Mesquita RC, Mathew LK, Quinn ZL, Runge A, Liu L, Kim MN, Liang J, Schenkel S, Yodh AG, Keith B, Simon MC. Endothelial HIF-2α regulates murine pathological angiogenesis and revascularization processes. J Clin Invest 2012; 122:1427-43. [PMID: 22426208 PMCID: PMC3314446 DOI: 10.1172/jci57322] [Citation(s) in RCA: 157] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2011] [Accepted: 02/03/2012] [Indexed: 12/12/2022] Open
Abstract
Localized tissue hypoxia is a consequence of vascular compromise or rapid cellular proliferation and is a potent inducer of compensatory angiogenesis. The oxygen-responsive transcriptional regulator hypoxia-inducible factor 2α (HIF-2α) is highly expressed in vascular ECs and, along with HIF-1α, activates expression of target genes whose products modulate vascular functions and angiogenesis. However, the mechanisms by which HIF-2α regulates EC function and tissue perfusion under physiological and pathological conditions are poorly understood. Using mice in which Hif2a was specifically deleted in ECs, we demonstrate here that HIF-2α expression is required for angiogenic responses during hindlimb ischemia and for the growth of autochthonous skin tumors. EC-specific Hif2a deletion resulted in increased vessel formation in both models; however, these vessels failed to undergo proper arteriogenesis, resulting in poor perfusion. Analysis of cultured HIF-2α-deficient ECs revealed cell-autonomous increases in migration, invasion, and morphogenetic activity, which correlated with HIF-2α-dependent expression of specific angiogenic factors, including delta-like ligand 4 (Dll4), a Notch ligand, and angiopoietin 2. By stimulating Dll4 signaling in cultured ECs or restoring Dll4 expression in ischemic muscle tissue, we rescued most of the HIF-2α-dependent EC phenotypes in vitro and in vivo, emphasizing the critical role of Dll4/Notch signaling as a downstream target of HIF-2α in ECs. These results indicate that HIF-1α and HIF-2α fulfill complementary, but largely nonoverlapping, essential functions in pathophysiological angiogenesis.
Collapse
MESH Headings
- Adaptor Proteins, Signal Transducing
- Angiopoietin-2/genetics
- Angiopoietin-2/physiology
- Animals
- Basic Helix-Loop-Helix Transcription Factors/deficiency
- Basic Helix-Loop-Helix Transcription Factors/genetics
- Basic Helix-Loop-Helix Transcription Factors/physiology
- Calcium-Binding Proteins
- Cell Hypoxia
- Cell Movement
- Cells, Cultured/cytology
- Collateral Circulation/physiology
- Endothelial Cells/metabolism
- Hindlimb/blood supply
- Hypoxia-Inducible Factor 1, alpha Subunit/deficiency
- Hypoxia-Inducible Factor 1, alpha Subunit/genetics
- Hypoxia-Inducible Factor 1, alpha Subunit/physiology
- Intracellular Signaling Peptides and Proteins/genetics
- Intracellular Signaling Peptides and Proteins/physiology
- Ischemia/physiopathology
- Membrane Proteins/genetics
- Membrane Proteins/physiology
- Mice
- Mice, Inbred C57BL
- Mice, Knockout
- Mice, Transgenic
- Neovascularization, Pathologic/physiopathology
- Neovascularization, Physiologic/physiology
- Receptors, Notch/physiology
- Recombinant Fusion Proteins/physiology
- Recovery of Function
- Skin Neoplasms/blood supply
- Skin Neoplasms/chemically induced
- Wound Healing/physiology
Collapse
Affiliation(s)
- Nicolas Skuli
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Amar J. Majmundar
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Bryan L. Krock
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Rickson C. Mesquita
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Lijoy K. Mathew
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Zachary L. Quinn
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Anja Runge
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Liping Liu
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Meeri N. Kim
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Jiaming Liang
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Steven Schenkel
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Arjun G. Yodh
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Brian Keith
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - M. Celeste Simon
- Howard Hughes Medical Institute,
Abramson Family Cancer Research Institute,
School of Medicine,
Department of Physics and Astronomy,
Department of Cancer Biology, and
Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
33
|
Yu G. Near-infrared diffuse correlation spectroscopy in cancer diagnosis and therapy monitoring. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:010901. [PMID: 22352633 PMCID: PMC3380819 DOI: 10.1117/1.jbo.17.1.010901] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2011] [Revised: 11/08/2011] [Accepted: 11/14/2011] [Indexed: 05/19/2023]
Abstract
A novel near-infrared (NIR) diffuse correlation spectroscopy (DCS) for tumor blood flow measurement is introduced in this review paper. DCS measures speckle fluctuations of NIR diffuse light in tissue, which are sensitive to the motions of red blood cells. DCS offers several attractive new features for tumor blood flow measurement such as noninvasiveness, portability, high temporal resolution, and relatively large penetration depth. DCS technology has been utilized for continuous measurement of tumor blood flow before, during, and after cancer therapies. In those pilot investigations, DCS hemodynamic measurements add important new variables into the mix for differentiation of benign from malignant tumors and for prediction of treatment outcomes. It is envisaged that with more clinical applications in large patient populations, DCS might emerge as an important method of choice for bedside management of cancer therapy, and it will certainly provide important new information about cancer physiology that may be of use in diagnosis.
Collapse
Affiliation(s)
- Guoqiang Yu
- University of Kentucky, Center for Biomedical Engineering, Lexington, Kentucky 40506-0070, USA.
| |
Collapse
|
34
|
Majmundar AJ, Skuli N, Mesquita RC, Kim MN, Yodh AG, Nguyen-McCarty M, Simon MC. O(2) regulates skeletal muscle progenitor differentiation through phosphatidylinositol 3-kinase/AKT signaling. Mol Cell Biol 2012; 32:36-49. [PMID: 22006022 PMCID: PMC3255700 DOI: 10.1128/mcb.05857-11] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2011] [Accepted: 10/09/2011] [Indexed: 12/11/2022] Open
Abstract
Skeletal muscle stem/progenitor cells, which give rise to terminally differentiated muscle, represent potential therapies for skeletal muscle diseases. Delineating the factors regulating these precursors will facilitate their reliable application in human muscle repair. During embryonic development and adult regeneration, skeletal muscle progenitors reside in low-O(2) environments before local blood vessels and differentiated muscle form. Prior studies established that low O(2) levels (hypoxia) maintained muscle progenitors in an undifferentiated state in vitro, although it remained unclear if progenitor differentiation was coordinated with O(2) availability in vivo. In addition, the molecular signals linking O(2) to progenitor differentiation are incompletely understood. Here we show that the muscle differentiation program is repressed by hypoxia in vitro and ischemia in vivo. Surprisingly, hypoxia can significantly impair differentiation in the absence of hypoxia-inducible factors (HIFs), the primary developmental effectors of O(2). In order to maintain the undifferentiated state, low O(2) levels block the phosphatidylinositol 3-kinase/AKT pathway in a predominantly HIF1α-independent fashion. O(2) deprivation affects AKT activity by reducing insulin-like growth factor I receptor sensitivity to growth factors. We conclude that AKT represents a key molecular link between O(2) and skeletal muscle differentiation.
Collapse
Affiliation(s)
- Amar J. Majmundar
- Abramson Family Cancer Research Institute
- Department of Cell and Developmental Biology
| | - Nicolas Skuli
- Abramson Family Cancer Research Institute
- Department of Cell and Developmental Biology
| | - Rickson C. Mesquita
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Meeri N. Kim
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Arjun G. Yodh
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | | - M. Celeste Simon
- Abramson Family Cancer Research Institute
- Department of Cell and Developmental Biology
- Howard Hughes Medical Institute, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
35
|
Mesquita RC, Durduran T, Yu G, Buckley EM, Kim MN, Zhou C, Choe R, Sunar U, Yodh AG. Direct measurement of tissue blood flow and metabolism with diffuse optics. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2011; 369:4390-406. [PMID: 22006897 PMCID: PMC3263785 DOI: 10.1098/rsta.2011.0232] [Citation(s) in RCA: 121] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Diffuse optics has proven useful for quantitative assessment of tissue oxy- and deoxyhaemoglobin concentrations and, more recently, for measurement of microvascular blood flow. In this paper, we focus on the flow monitoring technique: diffuse correlation spectroscopy (DCS). Representative clinical and pre-clinical studies from our laboratory illustrate the potential of DCS. Validation of DCS blood flow indices in human brain and muscle is presented. Comparison of DCS with arterial spin-labelled MRI, xenon-CT and Doppler ultrasound shows good agreement (0.50<r<0.95) over a wide range of tissue types and source detector distances, corroborating the potential of the method to measure perfusion non-invasively and in vivo at the microvasculature level. All-optical measurements of cerebral oxygen metabolism in both rat brain, following middle cerebral artery occlusion, and human brain, during functional activation, are also described. In both situations, the use of combined DCS and diffuse optical spectroscopy/near-infrared spectroscopy to monitor changes in oxygen consumption by the tissue is demonstrated. Finally, recent results spanning from gene expression-induced angiogenic response to stroke care and cancer treatment monitoring are discussed. Collectively, the research illustrates the capability of DCS to quantitatively monitor perfusion from bench to bedside, providing results that match up both with literature findings and with similar experiments performed with other techniques.
Collapse
Affiliation(s)
- Rickson C Mesquita
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Shang Y, Chen L, Toborek M, Yu G. Diffuse optical monitoring of repeated cerebral ischemia in mice. OPTICS EXPRESS 2011; 19:20301-15. [PMID: 21997041 PMCID: PMC3495871 DOI: 10.1364/oe.19.020301] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2011] [Revised: 09/09/2011] [Accepted: 09/09/2011] [Indexed: 05/18/2023]
Abstract
Occlusions of bilateral common carotid arteries (bi-CCA) in mice are popular models for the investigation of transient forebrain ischemia. Currently available technologies for assessing cerebral blood flow (CBF) and oxygenation in ischemic mice have limitations. This study tests a novel near-infrared diffuse correlation spectroscopy (DCS) flow-oximeter for monitoring both CBF and cerebral oxygenation in mice undergoing repeated transient forebrain ischemia. Concurrent flow measurements in a mouse brain were first conducted for validation purposes; DCS measurement was found highly correlated with laser Doppler measurement (R2 = 0.94) and less susceptible to motion artifacts. With unique designs in experimental protocols and fiber-optic probes, we have demonstrated high sensitivities of DCS flow-oximeter in detecting the regional heterogeneity of CBF responses in different hemispheres and global changes of both CBF and cerebral oxygenation across two hemispheres in mice undergoing repeated 2-minute bi-CCA occlusions over 5 days. More than 75% CBF reductions were found during bi-CCA occlusions in mice, which may be considered as a threshold to determine a successful bi-CCA occlusion. With the progress of repeated 2-minute bi-CCA occlusions over days, a longitudinal decline in the magnitudes of CBF reduction was observed, indicating the brain adaptation to cerebral ischemia through the repeated preconditioning.
Collapse
Affiliation(s)
- Yu Shang
- Center for Biomedical Engineering, University of Kentucky, Lexington, Kentucky 40506,
USA
| | - Lei Chen
- Department of Neurosurgery, University of Kentucky, Lexington, Kentucky 40536,
USA
| | - Michal Toborek
- Department of Neurosurgery, University of Kentucky, Lexington, Kentucky 40536,
USA
| | - Guoqiang Yu
- Center for Biomedical Engineering, University of Kentucky, Lexington, Kentucky 40506,
USA
| |
Collapse
|
37
|
Irwin D, Dong L, Shang Y, Cheng R, Kudrimoti M, Stevens SD, Yu G. Influences of tissue absorption and scattering on diffuse correlation spectroscopy blood flow measurements. BIOMEDICAL OPTICS EXPRESS 2011; 2:1969-85. [PMID: 21750773 PMCID: PMC3130582 DOI: 10.1364/boe.2.001969] [Citation(s) in RCA: 92] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2011] [Revised: 06/13/2011] [Accepted: 06/14/2011] [Indexed: 05/19/2023]
Abstract
In this study we evaluate the influences of optical property assumptions on near-infrared diffuse correlation spectroscopy (DCS) flow index measurements. The optical properties, absorption coefficient (µ(a)) and reduced scattering coefficient (µ(s)'), are independently varied using liquid phantoms and measured concurrently with the flow index using a hybrid optical system combining a dual-wavelength DCS flow device with a commercial frequency-domain tissue-oximeter. DCS flow indices are calculated at two wavelengths (785 and 830 nm) using measured µ(a) and µ(s)' or assumed constant µ(a) and µ(s)'. Inaccurate µ(s)' assumptions resulted in much greater flow index errors than inaccurate µ(a). Underestimated/overestimated µ(s)' from -35%/+175% lead to flow index errors of +110%/-80%, whereas underestimated/overestimated µ(a) from -40%/+150% lead to -20%/+40%, regardless of the wavelengths used. Examination of a clinical study involving human head and neck tumors indicates up to +280% flow index errors resulted from inter-patient optical property variations. These findings suggest that studies involving significant µ(a) and µ(s)' changes should concurrently measure flow index and optical properties for accurate extraction of blood flow information.
Collapse
Affiliation(s)
- Daniel Irwin
- Center for Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Lixin Dong
- Center for Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Yu Shang
- Center for Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Ran Cheng
- Center for Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| | - Mahesh Kudrimoti
- Department of Radiation Medicine, University of Kentucky Chandler Hospital, Lexington, KY 40536, USA
| | - Scott D. Stevens
- Department of Radiology, University of Kentucky Chandler Hospital, Lexington, KY 40536, USA
| | - Guoqiang Yu
- Center for Biomedical Engineering, University of Kentucky, Lexington, KY 40506, USA
| |
Collapse
|
38
|
Diop M, Verdecchia K, Lee TY, St Lawrence K. Calibration of diffuse correlation spectroscopy with a time-resolved near-infrared technique to yield absolute cerebral blood flow measurements. BIOMEDICAL OPTICS EXPRESS 2011; 2:2068-81. [PMID: 21750781 PMCID: PMC3130590 DOI: 10.1364/boe.2.002068] [Citation(s) in RCA: 91] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/19/2011] [Revised: 06/23/2011] [Accepted: 06/25/2011] [Indexed: 05/18/2023]
Abstract
A primary focus of neurointensive care is the prevention of secondary brain injury, mainly caused by ischemia. A noninvasive bedside technique for continuous monitoring of cerebral blood flow (CBF) could improve patient management by detecting ischemia before brain injury occurs. A promising technique for this purpose is diffuse correlation spectroscopy (DCS) since it can continuously monitor relative perfusion changes in deep tissue. In this study, DCS was combined with a time-resolved near-infrared technique (TR-NIR) that can directly measure CBF using indocyanine green as a flow tracer. With this combination, the TR-NIR technique can be used to convert DCS data into absolute CBF measurements. The agreement between the two techniques was assessed by concurrent measurements of CBF changes in piglets. A strong correlation between CBF changes measured by TR-NIR and changes in the scaled diffusion coefficient measured by DCS was observed (R(2) = 0.93) with a slope of 1.05 ± 0.06 and an intercept of 6.4 ± 4.3% (mean ± standard error).
Collapse
Affiliation(s)
- Mamadou Diop
- Imaging Program, Lawson Health Research Institute, London, Ontario N6A 4V2, Canada
- Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 3K7, Canada
| | - Kyle Verdecchia
- Imaging Program, Lawson Health Research Institute, London, Ontario N6A 4V2, Canada
- Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 3K7, Canada
| | - Ting-Yim Lee
- Imaging Program, Lawson Health Research Institute, London, Ontario N6A 4V2, Canada
- Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 3K7, Canada
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6G 2V4, Canada
| | - Keith St Lawrence
- Imaging Program, Lawson Health Research Institute, London, Ontario N6A 4V2, Canada
- Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 3K7, Canada
| |
Collapse
|