1
|
Abdelmissih S, Ahmed Rashed L, Sharif Ismail Negm M, Mohamed Sayed W, Mahmoud HM, Elmorsy S. Dabigatran Combined With Benztropine Ameliorates Cobalt Chloride-Induced Parkinsonism in Rats, Restores Protease-Activated Receptor 1 (PAR1), and Mitigates Oxidative Stress. Cureus 2025; 17:e80486. [PMID: 40225545 PMCID: PMC11991752 DOI: 10.7759/cureus.80486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/12/2025] [Indexed: 04/15/2025] Open
Abstract
BACKGROUND The presumed implication of thromboembolic and oxidative stress pathways in parkinsonism guided the current research toward the exploration of the anticoagulant dabigatran etexilate (DE) as a thrombin inhibitor in the cobalt chloride (CoCl2)-induced parkinsonism (CIP) model, a model of significance to industrial toxins-related health issues. METHODS Oral CoCl2 (12.5 mg/kg) was administered daily for 60 days, with the introduction of benztropine mesylate (BM) (10 mg/kg) and/or DE (3 mg/kg) on day 31. Rearing, postural instability, and pasta handling were evaluated, followed by histopathologic examination of the substantia nigra (SN) and striatum (STR). The expressions of brain dopamine receptor 2 (D2 ), adenosine receptor 1 (A1) and 2A (A2A), and protease-activated receptor 1 (PAR1), as well as the brain levels of dopamine (DA), endothelin 1 (ET1), malondialdehyde (MDA), and glutathione (GSH), were assessed. RESULTS BM+DE restored the number of rears to the control level, compared to being reduced in the CIP model. BM+DE restored the first, second, third, and average displacement distances to the control level, compared to being reduced in the CIP model. BM+DE was superior to either BM or DE in restoring the time to finish eating pasta and the number of adjustments of forepaws while eating to control levels after being affected in the CIP model. BM+DE restored DA to the control level and was superior to DE in restoring D2 to the control level. BM+DE was superior to BM in restoring A1 and A2A , increasing A1/A2A beyond the control level. BM+DE was superior to BM in restoring PAR1 and ET1 to control levels. BM+DE was superior to BM in restoring MDA to the control level and was superior to both BM and DE in increasing GSH beyond the control level. BM+DE exhibited the highest percentage of preserved neurons in SN, which was negatively correlated with MDA. CONCLUSION BM+DE offers a therapeutic potential for parkinsonism triggered by chronic exposure to CoCl2. The implication of thrombin-related factors and oxidative stress in the modulation of the dopaminergic-adenosinergic crosstalk is plausible.
Collapse
Affiliation(s)
- Sherine Abdelmissih
- Department of Medical Pharmacology, Faculty of Medicine Kasr Al-Ainy, Cairo University, Cairo, EGY
| | - Laila Ahmed Rashed
- Department of Medical Biochemistry and Molecular Biology, Faculty of Medicine Kasr Al-Ainy, Cairo University, Cairo, EGY
| | | | - Walaa Mohamed Sayed
- Department of Anatomy and Embryology, Faculty of Medicine Kasr Al-Ainy, Cairo University, Cairo, EGY
| | - Hesham M Mahmoud
- Department of Medical Pharmacology, Faculty of Medicine Kasr Al-Ainy, Cairo University, Cairo, EGY
| | - Soha Elmorsy
- Department of Medical Pharmacology, Faculty of Medicine Kasr Al-Ainy, Cairo University, Cairo, EGY
| |
Collapse
|
2
|
Ji C, Chen Y, Si M, Chen X. The impact of biocorrosion and titanium ions release on peri-implantitis. Clin Oral Investig 2025; 29:155. [PMID: 39998661 DOI: 10.1007/s00784-025-06186-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2024] [Accepted: 01/20/2025] [Indexed: 02/27/2025]
Abstract
OBJECTIVES Biofilm accumulation is considered the primary cause of peri-implant inflammation. Still, metallosis caused by an increased concentration of titanium ions at the site of peri-implantitis site cannot be ignored. Whether titanium ions alone or in concert with bacterial biofilm trigger inflammation and bone destruction in peri-implant tissues remains unproven. MATERIALS AND METHODS Articles were retrieved from PubMed/Medline, Web of Science. All studies focusing on titanium ions release in peri-implant reactions were included and evaluated. RESULTS Titanium implants are considered non-inert and may release titanium ions in the intraoral microenvironment, the most important of which is the acidic environment created by bacterial biofilms. Although the correlation between titanium ion release and the incidence or progression of peri-implantitis is controversial, several studies have confirmed the potential role of titanium ions. Diffusion or entry of titanium ions into the circulation may be a scavenging effect on local titanium ions but can cause systemic adverse effects. However, existing measures are not yet able to balance reducing biocorrosion and maintaining osteogenic results, and the exploration of new materials requires long-term clinical data. CONCLUSIONS Titanium ions have potential impacts on peri-implant tissue and systemic circulation. Titanium ions are closely associated with bacterial biofilms in the occurrence and development of periimplantitis. The preventive strategies for the release and action of titanium ions remain to be explored. CLINICAL RELEVANCE Our findings may provide the hope of shedding light on the pathogenesis of peri-implantitis and its treatment.
Collapse
Affiliation(s)
- Chonghao Ji
- Stomatology Hospital, School of Stomatology, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Zhejiang University School of Medicine, Cancer Center of Zhejiang University, Hangzhou, China
| | - Yaqian Chen
- Stomatology Hospital, School of Stomatology, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Zhejiang University School of Medicine, Cancer Center of Zhejiang University, Hangzhou, China
| | - Misi Si
- Stomatology Hospital, School of Stomatology, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Zhejiang University School of Medicine, Cancer Center of Zhejiang University, Hangzhou, China.
| | - Xiaoyan Chen
- Stomatology Hospital, School of Stomatology, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Zhejiang University School of Medicine, Cancer Center of Zhejiang University, Hangzhou, China.
| |
Collapse
|
3
|
Ciatti C, Andriollo L, Asti C, Morsia D, Quattrini F, Cosentino M, Bordini B. The role of femoral head size in metal-on-metal hip arthroplasty: analysis of a cohort of 3813 patients with long term follow-up. Arch Orthop Trauma Surg 2024; 144:4809-4818. [PMID: 39496883 PMCID: PMC11582203 DOI: 10.1007/s00402-024-05567-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Accepted: 09/09/2024] [Indexed: 11/06/2024]
Abstract
Metal-on-metal (MoM) large headed arthroplasties were suggested to decrease failure rates by means of reduced volumetric wear and enhanced implant stability. However, they caused high rates of revisions due to adverse reaction to metal debris, osteolysis, pseudotumor growth, and other issues. The study aims to present the long-term outcomes of MoM arthroplasties on a large cohort of patients, evaluating the impact of head sizes on survival rate. All data were retrieved from the regional joint register (Registro dell'Implantologia Protesica Ortopedica, RIPO, Italy). We include in the study all patient who underwent cementless MoM total hip arthroplasties (THAs) between 2000 and 2020, dividing them in two subgroups according to head size (<36 mm, ≥36 mm). Failures were recorded up to December 31, 2020. Patients lost to follow-up were excluded. A total of 3813 THAs met the inclusion/exclusion criteria. The average follow-up period is 12.4 years (0-21 years). 178/1625 (or 11.0%) small head MoM THAs and 265/2188 large head ones failed by the end of follow up. Large diameter heads reported lower survival rate (p-value < 0.001), with unexpected higher dislocation rate (1.0 vs. 0.4%). Moreover, large head size was found to increases the risk of metallosis (p-value < 0.0001). Gender, patient's age and the use of modular neck were not correlated with higher failure rates. MoM implants implants do not have the same reliability as other couplings, considering the significantly greater failure/complication rates. However, the knowledge of risks linked to head size is fundamental for establishing the right type of follow-up to the patient and recognize any complications early.
Collapse
Affiliation(s)
- Corrado Ciatti
- University of Parma, Parma, Italy.
- Orthopaedics and Traumatology Department, Guglielmo da Saliceto Hospital, Via Taverna 49, Piacenza, Italy.
| | - Luca Andriollo
- Sezione di Chirurgia Protesica ad Indirizzo Robotico - Unità di Traumatologia dello Sport, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy
- Università Cattolica del Sacro Cuore, Roma, Italy
- Artificial Intelligence Center, Alma Mater Europea University, Vienna, Austria
| | - Chiara Asti
- Orthopaedics and Traumatology Department, Guglielmo da Saliceto Hospital, Via Taverna 49, Piacenza, Italy
| | - Davide Morsia
- University of Parma, Parma, Italy
- Orthopaedics and Traumatology Department, Guglielmo da Saliceto Hospital, Via Taverna 49, Piacenza, Italy
| | - Fabrizio Quattrini
- University of Parma, Parma, Italy
- Orthopaedics and Traumatology Department, Guglielmo da Saliceto Hospital, Via Taverna 49, Piacenza, Italy
| | - Monica Cosentino
- Medical Technology Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Barbara Bordini
- Medical Technology Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
4
|
Richter-Bisson ZW, Nie HY, Hedberg YS. Serum protein albumin and chromium: Mechanistic insights into the interaction between ions, nanoparticles, and protein. Int J Biol Macromol 2024; 278:134845. [PMID: 39159799 DOI: 10.1016/j.ijbiomac.2024.134845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2024] [Revised: 08/14/2024] [Accepted: 08/16/2024] [Indexed: 08/21/2024]
Abstract
The interaction of human proteins and metal species, both ions and nanoparticles, is poorly understood despite their growing importance. These materials are the by-products of corrosion processes and are of relevance for food and drug manufacturing, nanomedicine, and biomedical implant corrosion. Here, we study the interaction of Cr(III) ions and chromium oxide nanoparticles with bovine serum albumin in physiological conditions. This study combined electrophoretic mobility measurements, spectroscopy, and time-of-flight secondary ion mass spectrometry with principal component analysis. It was determined that neither metal species resulted in global albumin unfolding. The Cr(III) ions interacted strongly with amino acids found in previously discovered metal binding sites, but also were most strongly implicated in the interaction with negatively charged acid residues, suggesting an electrostatic interaction. Bovine serum albumin (BSA) was found to bind to the Cr2O3 nanoparticles in a preferential orientation, due to electrostatic interactions between the positive amino acid residues and the negative chromium oxide nanoparticle surface. These findings ameliorate our understanding of the interaction between trivalent chromium ions and nanoparticles, and biological macromolecules.
Collapse
Affiliation(s)
| | - Heng-Yong Nie
- Surface Science Western, Western University, London, ON N6G 0J3, Canada; Department of Physics and Astronomy, Western University, London, ON N6A 3K7, Canada
| | - Yolanda Susanne Hedberg
- Department of Chemistry, Western University, London, ON N6A 5B7, Canada; Surface Science Western, Western University, London, ON N6G 0J3, Canada; Lawson Health Research Institute, London, ON N6C 2R5, Canada.
| |
Collapse
|
5
|
Zhong Q, Pan X, Chen Y, Lian Q, Gao J, Xu Y, Wang J, Shi Z, Cheng H. Prosthetic Metals: Release, Metabolism and Toxicity. Int J Nanomedicine 2024; 19:5245-5267. [PMID: 38855732 PMCID: PMC11162637 DOI: 10.2147/ijn.s459255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 05/13/2024] [Indexed: 06/11/2024] Open
Abstract
The development of metallic joint prostheses has been ongoing for more than a century alongside advancements in hip and knee arthroplasty. Among the materials utilized, the Cobalt-Chromium-Molybdenum (Co-Cr-Mo) and Titanium-Aluminum-Vanadium (Ti-Al-V) alloys are predominant in joint prosthesis construction, predominantly due to their commendable biocompatibility, mechanical strength, and corrosion resistance. Nonetheless, over time, the physical wear, electrochemical corrosion, and inflammation induced by these alloys that occur post-implantation can cause the release of various metallic components. The released metals can then flow and metabolize in vivo, subsequently causing potential local or systemic harm. This review first details joint prosthesis development and acknowledges the release of prosthetic metals. Second, we outline the metallic concentration, biodistribution, and elimination pathways of the released prosthetic metals. Lastly, we discuss the possible organ, cellular, critical biomolecules, and significant signaling pathway toxicities and adverse effects that arise from exposure to these metals.
Collapse
Affiliation(s)
- Qiang Zhong
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Xin Pan
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Yuhang Chen
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Qiang Lian
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Jian Gao
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Yixin Xu
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Jian Wang
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Zhanjun Shi
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| | - Hao Cheng
- Department of Orthopedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong Province, People’s Republic of China
| |
Collapse
|
6
|
Tigani D, Solito L, Stallone S, Leonida CM, Dieterich T, Taverniti F, Banci L, Melucci G. Dual Mobility Hip Arthroplasty: Innovative Technological Advances. PROSTHESIS 2024; 6:393-400. [DOI: 10.3390/prosthesis6020029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
Abstract
The use of 3D-printed highly porous titanium acetabular cups in total hip arthroplasty (THA) is increasing. The porosity and mechanical properties of such highly porous titanium structures mimic those of natural cancellous bone, possibly allowing biological implant fixation to be improved. Recently, a 3D-printed highly porous Dual Mobility (DM) monobloc construct fully manufactured using Ti6Al4V alloy, with a titanium–niobium nitride (TiNbN) ceramic coating on the articular side to allow articulation against the mobile liner by improving the titanium vs. polyethylene tribological behavior, was introduced in THA. To the best of our knowledge, this is the first highly porous titanium monobloc DM implant on the market. The reasons for using a Ti alloy highly porous DM are multifarious: to prevent any possible adverse reactions due to the corrosion of Cobalt–Chromium–Molybdenum Alloy (CoCrMo) and Stainless Steel (SS) implants and to improve implant primary and secondary stability, particularly in cases of poor bone quality. Finally, with the introduction of an inner TiNbN ceramic coating surface, it was possible to overcome the poor tribological quality of titanium. Another interesting characteristic is this material’s higher implant radiolucency, which might facilitate the radiographic assessment of cup orientation, which can, in turn, facilitate the detection of any intraprosthetic dislocation (IPD) and the measurement of polyethylene wear, which is very important in the study of the durability of THA.
Collapse
Affiliation(s)
- Domenico Tigani
- U.O.C. Ortopedia e Traumatologia, Ospedale Maggiore “C.A. Pizzardi”, 40133 Bologna, Italy
| | - Ludovica Solito
- U.O.C. Ortopedia e Traumatologia, Ospedale Maggiore “C.A. Pizzardi”, 40133 Bologna, Italy
| | - Stefano Stallone
- U.O.C. Ortopedia e Traumatologia, Ospedale Maggiore “C.A. Pizzardi”, 40133 Bologna, Italy
| | - Corrado Maria Leonida
- U.O.C. Ortopedia e Traumatologia, Ospedale Maggiore “C.A. Pizzardi”, 40133 Bologna, Italy
| | - Tommaso Dieterich
- U.O.C. Ortopedia e Traumatologia, Ospedale Maggiore “C.A. Pizzardi”, 40133 Bologna, Italy
| | - Francesco Taverniti
- U.O.C. Ortopedia e Traumatologia, Ospedale Maggiore “C.A. Pizzardi”, 40133 Bologna, Italy
| | - Lorenzo Banci
- Clinical Research—Permedica Orthopaedics, 23807 Merate, Italy
| | - Giuseppe Melucci
- U.O.C. Ortopedia e Traumatologia, Ospedale Maggiore “C.A. Pizzardi”, 40133 Bologna, Italy
| |
Collapse
|
7
|
Al-Khatib Y, Tyas B, Kalson NS, Agni N, Bhutani P, Petheram T, Carluke I, Partington P. Quantification and severity grading of femoral vessel compression by adverse reactions to metal debris in metal-on-metal total hip arthroplasty. Hip Int 2024; 34:215-220. [PMID: 37545332 DOI: 10.1177/11207000231190738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/08/2023]
Abstract
INTRODUCTION Metal-on-metal (MoM) total hip arthroplasty (THA) may cause adverse reactions to metal debris (ARMD). ARMD causing femoral vessel compression with serious complications has been described in case reports, but the rate of compression by ARMD is not known. This study aims to investigate the rate, and quantify the severity, of femoral vessel compression in MoM hips with ARMD lesions. METHODS Patients under surveillance for MoM THA investigated with MRI were studied. In patients with confirmed ARMD, femoral artery (FA) and vein (FV) diameters were measured at the point of maximal compression and compared to contralateral vessels. The primary outcome measure was presence or absence of compression. Cases were then classified by compression ratios. Secondary outcome measures were rates of deep vein thrombosis, revision surgery and time to ARMD from index procedure. RESULTS MRI scans for 436 patients with MoM THA were screened. Of these, 211/436 (48.4%) showed evidence of ARMD. Measurements were obtained on 133/211 (63.0%) patients. The FV was compressed in 102/133 (76.7%) and FA in 58/133 (43.6%), while 31/133 (23.3%) patients had no compression. In FVs, 42 demonstrated mild compression, 39 moderate and 21 severe. In FAs, none were severely compressed, 6 were moderate and 52 showed mild compression. There were 3 DVT cases, 2 in patients with moderate FV compression and 1 in patients without FV compression. Revision rates were highest in patients with severe FV compression (14/21, 66.7%). The mean time for MRI-diagnosed ARMD from index procedure was 8 years and 1 month (range 11 months-14.5 years). CONCLUSIONS Extra-luminal compression of the femoral vessels was found in >75% of patients with ARMD. Although it is not clear whether revision for femoral vessel compression is required, quantification of FV compression may be useful for surgeons and radiologists considering revision for ARMD.
Collapse
Affiliation(s)
| | - Ben Tyas
- Trauma and Orthopaedics, Health Education North East, Newcastle Upon Tyne, UK
| | - Nicholas S Kalson
- Department of Orthopaedics, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| | - Nickil Agni
- Department of Orthopaedics, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| | - Priyesh Bhutani
- Department of Radiology, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| | - Timothy Petheram
- Department of Orthopaedics, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| | - Ian Carluke
- Department of Orthopaedics, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| | - Paul Partington
- Department of Orthopaedics, Northumbria Healthcare NHS Foundation Trust, Newcastle Upon Tyne, UK
| |
Collapse
|
8
|
Regis D, Lugani G, Valentini A, Sandri A, Ambrosini C, Bagnis F, Dorigotti A, Negri S, Magnan B. Mid-term clinical and radiographic outcome of metal-on-metal hip resurfacing through an anterolateral approach. Musculoskelet Surg 2023; 107:439-446. [PMID: 37285004 DOI: 10.1007/s12306-023-00789-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Accepted: 05/17/2023] [Indexed: 06/08/2023]
Abstract
PURPOSE The aim of this retrospective study was to evaluate the medium-term clinical and radiographic results of current generation metal-on-metal resurfacing prostheses performed through anterolateral approach. MATERIALS AND METHODS Fifty-seven hips in 52 patients underwent resurfacing arthroplasty. Two patients died from unrelated causes, leaving 55 hips in 35 males (3 bilateral) and 15 females (2 bilateral), with a mean age at surgery of 56.2 years (range, 27-70 years). Clinical and radiographic assessment was carried out preoperatively and at follow-up in all the survived cases. The cumulative survival rate was determined according to the method of Kaplan-Meier. RESULTS At a mean follow-up of 5.2 years (range, 1.8-9.1 years), 2 HRs of the same female patient were revised because of early loosening of the acetabular component. Deep venous thrombosis and transient femoral nerve palsy occurred both in 1 case. No specific complications of HR were observed. Average Harris hip score improved significantly from 59.8 points (range, 30.4-90.6) preoperatively to 93.7 points (range, 53-100) at the latest examination. Neck narrowing showed an average of 3.27%, but it never exceeded 10%. Nonprogressive acetabular radiolucencies and osteolysis were detected both in 2 hips. A high rate of patients (32, 60.4%) developed heterotopic ossifications, although low-grade in most cases (27, 84.4%). The cumulative survival rate at 9.1 years with revision for any reason as the end point was 93.0%. CONCLUSIONS The early clinical and radiographic results of modern metal-on-metal hip resurfacing performed through an anterolateral approach are promising, but longer-term follow-up studies are necessary.
Collapse
Affiliation(s)
- D Regis
- Department of Orthopaedic and Trauma Surgery, Azienda Ospedaliera Universitaria Integrata di Verona, Piazzale A Stefani 1, 37126, Verona, Italy.
| | - G Lugani
- Department of Orthopaedic and Trauma Surgery, Azienda Ospedaliera Universitaria Integrata di Verona, Piazzale A Stefani 1, 37126, Verona, Italy
| | - A Valentini
- Department of Orthopaedics and Traumatology, Ospedale Valli del Noce, Viale de Gasperi 31, 38023, Cles, Italy
| | - A Sandri
- Department of Orthopaedic and Trauma Surgery, Azienda Ospedaliera Universitaria Integrata di Verona, Piazzale A Stefani 1, 37126, Verona, Italy
| | - C Ambrosini
- Department of Orthopaedic and Trauma Surgery, Azienda Ospedaliera Universitaria Integrata di Verona, Piazzale A Stefani 1, 37126, Verona, Italy
| | - F Bagnis
- Department of Orthopaedic and Trauma Surgery, Azienda Ospedaliera Universitaria Integrata di Verona, Piazzale A Stefani 1, 37126, Verona, Italy
| | - A Dorigotti
- Department of Orthopaedic and Trauma Surgery, Azienda Ospedaliera Universitaria Integrata di Verona, Piazzale A Stefani 1, 37126, Verona, Italy
| | - S Negri
- Department of Orthopaedic and Trauma Surgery, Azienda Ospedaliera Universitaria Integrata di Verona, Piazzale A Stefani 1, 37126, Verona, Italy
| | - B Magnan
- Department of Orthopaedic and Trauma Surgery, Azienda Ospedaliera Universitaria Integrata di Verona, Piazzale A Stefani 1, 37126, Verona, Italy
| |
Collapse
|
9
|
Ude CC, Schmidt SJ, Laurencin S, Shah S, Esdaille J, Kan HM, Holt BD, Arnold AM, Wolf ME, Nair LS, Sydlik SA, Laurencin CT. Hyaluronic acid-British anti-Lewisite as a safer chelation therapy for the treatment of arthroplasty-related metallosis. Proc Natl Acad Sci U S A 2023; 120:e2309156120. [PMID: 37903261 PMCID: PMC10636327 DOI: 10.1073/pnas.2309156120] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Accepted: 09/17/2023] [Indexed: 11/01/2023] Open
Abstract
Cobalt-containing alloys are useful for orthopedic applications due to their low volumetric wear rates, corrosion resistance, high mechanical strength, hardness, and fatigue resistance. Unfortunately, these prosthetics release significant levels of cobalt ions, which was only discovered after their widespread implantation into patients requiring hip replacements. These cobalt ions can result in local toxic effects-including peri-implant toxicity, aseptic loosening, and pseudotumor-as well as systemic toxic effects-including neurological, cardiovascular, and endocrine disorders. Failing metal-on-metal (MoM) implants usually necessitate painful, risky, and costly revision surgeries. To treat metallosis arising from failing MoM implants, a synovial fluid-mimicking chelator was designed to remove these metal ions. Hyaluronic acid (HA), the major chemical component of synovial fluid, was functionalized with British anti-Lewisite (BAL) to create a chelator (BAL-HA). BAL-HA effectively binds cobalt and rescues in vitro cell vitality (up to 370% of cells exposed to IC50 levels of cobalt) and enhances the rate of clearance of cobalt in vivo (t1/2 from 48 h to 6 h). A metallosis model was also created to investigate our therapy. Results demonstrate that BAL-HA chelator system is biocompatible and capable of capturing significant amounts of cobalt ions from the hip joint within 30 min, with no risk of kidney failure. This chelation therapy has the potential to mitigate cobalt toxicity from failing MoM implants through noninvasive injections into the joint.
Collapse
Affiliation(s)
- Chinedu C. Ude
- The Cato T. Laurencin Institute for Regenerative Engineering, University of Connecticut, Farmington, CT06030
- Department of Orthopaedic Surgery, University of Connecticut Health, Farmington, CT06030
| | - Stephen J. Schmidt
- Department of Chemistry, Carnegie Mellon University, Pittsburgh, PA15213
| | - Samuel Laurencin
- The Cato T. Laurencin Institute for Regenerative Engineering, University of Connecticut, Farmington, CT06030
- Department of Orthopaedic Surgery, University of Connecticut Health, Farmington, CT06030
| | - Shiv Shah
- The Cato T. Laurencin Institute for Regenerative Engineering, University of Connecticut, Farmington, CT06030
- Department of Orthopaedic Surgery, University of Connecticut Health, Farmington, CT06030
- Department of Chemical and Biomolecular Engineering, University of Connecticut, Storrs, CT06269
| | - Jayson Esdaille
- The Cato T. Laurencin Institute for Regenerative Engineering, University of Connecticut, Farmington, CT06030
- Department of Orthopaedic Surgery, University of Connecticut Health, Farmington, CT06030
| | - Ho-Man Kan
- The Cato T. Laurencin Institute for Regenerative Engineering, University of Connecticut, Farmington, CT06030
- Department of Orthopaedic Surgery, University of Connecticut Health, Farmington, CT06030
| | - Brian D. Holt
- Department of Chemistry, Carnegie Mellon University, Pittsburgh, PA15213
| | - Anne M. Arnold
- Department of Chemistry, Carnegie Mellon University, Pittsburgh, PA15213
| | - Michelle E. Wolf
- Department of Chemistry, Carnegie Mellon University, Pittsburgh, PA15213
| | - Lakshmi S. Nair
- The Cato T. Laurencin Institute for Regenerative Engineering, University of Connecticut, Farmington, CT06030
- Department of Orthopaedic Surgery, University of Connecticut Health, Farmington, CT06030
- Department of Chemical and Biomolecular Engineering, University of Connecticut, Storrs, CT06269
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT06269
- Department of Materials Science and Engineering, University of Connecticut, Storrs, CT06269
- Institute of Materials Science, University of Connecticut, Storrs, CT06269
| | - Stefanie A. Sydlik
- Department of Chemistry, Carnegie Mellon University, Pittsburgh, PA15213
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA15213
| | - Cato T. Laurencin
- The Cato T. Laurencin Institute for Regenerative Engineering, University of Connecticut, Farmington, CT06030
- Department of Orthopaedic Surgery, University of Connecticut Health, Farmington, CT06030
- Department of Chemical and Biomolecular Engineering, University of Connecticut, Storrs, CT06269
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT06269
- Department of Materials Science and Engineering, University of Connecticut, Storrs, CT06269
- Institute of Materials Science, University of Connecticut, Storrs, CT06269
- Department of Craniofacial Sciences, School of Dental Medicine, University of Connecticut Health, Farmington, CT06030
| |
Collapse
|
10
|
Richter-Bisson ZW, Doktor A, Hedberg YS. Serum Albumin Aggregation Facilitated by Cobalt and Chromium Metal Ions. ACS APPLIED BIO MATERIALS 2023; 6:3832-3841. [PMID: 37610418 DOI: 10.1021/acsabm.3c00463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
The interaction of serum proteins with cobalt (Co) and chromium (Cr) ions is poorly understood, but it is suspected to result in protein aggregation, which may alter the corrosion process of biomedical CoCr alloys or result in adverse health effects. Here, we study the aggregation ability and mechanism of bovine serum albumin (BSA) induced or accelerated by aqueous Co(II) and Cr(III) ions. The metal salts were selected by chemical speciation modeling, and they did not affect the pH or precipitate under simulated physiological conditions (150 mM NaCl and pH 7.3). The counterion of Cr(III) influenced the binding to BSA only at physiologically irrelevant low ionic strength. This study used a variety of spectroscopic and light scattering methods. It was determined that both metal ions and an equimolar mixture of metal ions have the potential to induce protein aggregation. Melting curves collected by circular dichroism spectroscopy indicate that Co(II) significantly reduced BSA's melting temperature when compared with Cr(III) or an equimolar mixture of Co(II) and Cr(III), both of which increased the melting temperature of BSA. The metal ions in solution preferentially interacted with BSA, resulting in the depletion of metal ions from the surrounding protein-free solution. Finally, this study suggests that the likely mechanism for Co(II)- and Cr(III)-induced BSA aggregation is salt bridging between protein molecules.
Collapse
Affiliation(s)
| | - Aleksandra Doktor
- Department of Chemistry, Western University, London, ON N6A 5B7, Canada
| | - Yolanda Susanne Hedberg
- Department of Chemistry, Western University, London, ON N6A 5B7, Canada
- Surface Science Western, Western University, London, ON N6G 0J3, Canada
- Lawson Health Research Institute, London, ON N6C2R5, Canada
| |
Collapse
|
11
|
Migliorini F, Pilone M, Bell A, Merfort R, Giorgino R, Maffulli N. Serum cobalt and chromium concentration following total hip arthroplasty: a Bayesian network meta-analysis. Sci Rep 2023; 13:6918. [PMID: 37106086 PMCID: PMC10140036 DOI: 10.1038/s41598-023-34177-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 04/25/2023] [Indexed: 04/29/2023] Open
Abstract
The present systematic review investigated the concentration of chromium (Cr) and cobalt (Co) in serum in patients who have undergone total hip arthroplasty (THA). The first outcome of interest was to investigate the mean concentration in serum of Cr and Co using different material combinations and to verify whether their concentrations change significantly using different patterns of head and liner in THA. The second outcome of interest was to investigate whether the time elapsed from the index surgery to the follow-up, BMI, sex, and side exert an influence on the mean concentration of Cr and Co in serum in patients who have undergone THA. The following material combinations were investigated (head-liner): Ceramic-Co Cr (CoCr), CoCr-CoCr, CoCr-Polyethylene, CoCr high carbide-CoCr high carbide. Data from 2756 procedures were retrieved. The mean length of follow-up was 69.3 ± 47.7 months. The ANOVA test evidenced good comparability in age, length of follow-up, BMI, and sex (P > 0.1). In patients who have undergone THA, the mean concentration in the serum of Co ranged between 0.5 µg/L and 3.5 µg/L, and the mean concentration of Cr from 0.6 to 2.6 µg/L. The difference in the concentration of Co and Cr in serum is strictly related to the implant configuration, with the coupling CoCr-CoCr showing the highest and CoCr-Polyethylene showing the lowest concentration. Patient characteristics, BMI, sex, side and the time elapsed from the index surgery to the last follow-up did not exert a significant influence on the concentration of Co and Cr in serum in patients who have undergone total hip arthroplasty (THA).
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, 52152, Simmerath, Germany.
| | - Marco Pilone
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy
- Residency Program in Orthopedics and Traumatology, University of Milan, Milan, Italy
| | - Andreas Bell
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, 52152, Simmerath, Germany
| | - Ricarda Merfort
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Riccardo Giorgino
- Residency Program in Orthopedics and Traumatology, University of Milan, Milan, Italy
| | - Nicola Maffulli
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy
- School of Pharmacy and Bioengineering, Faculty of Medicine, Keele University, ST4 7QB, Stoke On Trent, England
- Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Queen Mary University of London, Mile End Hospital, E1 4DG, London, England
| |
Collapse
|
12
|
Costales TG, Greenwell PH, Shield W, Chapman DM, Griffin WL, Dalury DF. Poor Patient Follow-up After Metal-on-Metal Total Hip Arthroplasty. Orthopedics 2022; 45:e196-e200. [PMID: 35245138 DOI: 10.3928/01477447-20220225-03] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Routine follow-up approximately every 2 to 5 years after total hip arthroplasty (THA) is a common practice. However, although patients are informed of the importance of follow-up, our mean follow-up rate for patients after standard non-metal-on-metal (MOM) THA is only 19%. The US Food and Drug Administration has released several statements on the importance of follow-up every 2 years after MOM THA. With the potential risks of MOM THA apparently widely known, we report on our ability to obtain timely follow-up at 2 separate centers. Two separate centers performed 570 MOM THA procedures between 2002 and 2010. An attempt was made to reach every patient by either telephone or letter to obtain ion levels, radiographs, and examinations. Repeat telephone calls and/or letters to those not reached were made annually. Patients were told of the unique importance of follow-up at each contact. Of the patients, 43% had not been seen within the past 5 years, and only 26% had been seen within the past 2 years. Only 61% had their first measurement of ion levels, and only 30% of patients had a second set of measurement of ion levels. A total of 48 revisions occurred in this group, and 36 patients died. Despite the apparent widespread dissemination of information regarding the potential risks of MOM THA and concerted efforts to contact patients for follow-up, we have been able to achieve a follow-up rate of only 26%. This rate is only marginally better than the mean follow-up for non-MOM THA in our practices. The implications of this poor follow-up are unknown. [Orthopedics. 2022;45(4):e196-e200.].
Collapse
|
13
|
Abdel Hamid OI, Attia ME, Hirshon JM, El-Shinawi M, El-Hussaini M, El-Setouhy M. Psychiatric Disorders and Genotoxicity Following Primary Metal on Polyethylene Total Hip Arthroplasty and Their Correlation to Cobalt/Chromium Levels. Drug Healthc Patient Saf 2022; 14:97-111. [PMID: 35880007 PMCID: PMC9308046 DOI: 10.2147/dhps.s360643] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 07/04/2022] [Indexed: 11/23/2022] Open
Abstract
Introduction Hip arthroplasty (HA) using implantable metal components is among the commonest orthopedic interventions. However, it can be followed by several complications following corrosion and the release of metal ions. Several studies proved that damaged genomic DNA may contribute to the pathophysiology of mental disorders. Aim The current work aims to evaluate the psychiatric disorders in metal on polyethylene hip arthroplasty (MOP-HA) patients and its correlation to cobalt/chromium (Co/Cr) levels and genotoxicity. Methods The work was a longitudinal follow-up study including 34 adults with unilateral primary MOP-HA meeting the inclusion and exclusion criteria. Preoperatively, 6, 12-months-postoperatively, patients were examined for cognitive impairment using mini-mental-state-examination (MMSE), depression using major-depressive-inventory (MDI), and blood samples were collected for estimation of Co/Cr, detection of genotoxicity by single-cell-gel-electrophoresis (comet assay) and serum 8-hydroxy-2'-deoxyguanosine (8-OHdG). Results Cognitive impairment was reported in 18.5% and 14.8% at 6-months, and 12-months postoperative, respectively. Depressive disorder was recorded in 22.2% at 6-months and 14.8% at 12-months postoperative. The marginal homogeneity tests proved a non-significant difference. There was a non-significant difference in preoperative, 6-months, 12-months postoperative MMSE, and MDI scores. There were significantly increased Co/Cr levels at 6-months postoperative. The levels decreased at 12-months postoperative, however, still significantly higher than preoperative values. There was a significant increase in serum 8-OHdG and the levels were positively correlated to cobalt levels at both 6 and 12-months-postoperative. There was a non-significant difference among preoperative, 6-months, and 12-months postoperative comet assay measurements. Conclusion From previous findings, we can conclude that will-functioning MOP hip arthroplasty can induce increased ion levels and positively correlated increase in biochemical markers of genotoxicity (8-OHdG).
Collapse
Affiliation(s)
- Omaima I Abdel Hamid
- Forensic Medicine and Clinical Toxicology Department, Faculty of Medicine, Zagazig University, Zagazig, Egypt
| | - Mohamed E Attia
- Orthopedics Departments, Faculty of Medicine, Zagazig University, Zagazig, Egypt
| | - Jon M Hirshon
- Department of Emergency Medicine, University of Maryland, School of Medicine, Baltimore, MD, USA
- Department of Epidemiology and Public Health, University of Maryland, School of Medicine, Baltimore, MD, USA
| | - Mohamed El-Shinawi
- Department of General Surgery, Faculty of Medicine, Ain Shams University, Cairo, Egypt
- Galala University, Galala City, Suez, Egypt
| | - Moustafa El-Hussaini
- Department of Community, Environmental and Occupational Medicine, Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | - Maged El-Setouhy
- Department of Community, Environmental and Occupational Medicine, Faculty of Medicine, Ain Shams University, Cairo, Egypt
- Department of Family and Community Medicine, Faculty of Medince, Jazan University, Jazan, Kingdom of Saudi Arabia
| |
Collapse
|
14
|
Agarwala S, Vijayvargiya M. Predictive factors affecting long-term survivorship of ASR metal-on-metal total hip arthroplasty. SICOT J 2021; 7:51. [PMID: 34668856 PMCID: PMC8527991 DOI: 10.1051/sicotj/2021040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 07/14/2021] [Indexed: 12/30/2022] Open
Abstract
INTRODUCTION We present the outcome of 154 ASR (Articular Surface Replacement) hips performed at the P.D Hinduja Hospital and Medical Research Centre in terms of revision rate, metal ion levels, and factors affecting survivorship. Further, determined the importance of serial metal ion estimation over single value with poorly functioning arthroplasties. METHODS A retrospective study of 154 ASR arthroplasties (136 patients) performed from April 2005 till March 2010 was conducted. Ninety-seven patients were available for final analysis. All patients were assessed for symptoms, radiographs, blood metal (chromium and cobalt), metal artefact reduction sequence (MARS), magnetic resonance imaging (MRI), and computerized tomography (CT). RESULTS Female gender, smaller femoral head, patients with a rising level of metal ion levels were more likely to have revision surgery. However, abnormal acetabular inclination/anteversion was not associated with the occurrence of raised metal ion levels, ARMD (adverse reaction to metal debris) or revision surgery. Patients with raised metal ion levels were more likely to have periprosthetic lucency, ARMD, and revision surgery. Median metal levels increased initially for the first three years. Still, patients who required revision surgery continued to have a metal ion rise until the point when revision surgery was performed. In contrast, patients who had a fall in metal ion levels did not require revision. CONCLUSION A single metal ion value is less predictive of failing arthroplasties; instead, a rising trend of metal ion levels can better delineate arthroplasties which will require revision. ASR hips whose blood ion levels fell after an initial rise and showed a declining trend did well.
Collapse
Affiliation(s)
- Sanjay Agarwala
- Chief of Surgery and Director Professional Services, P.D Hinduja Hospital and Medical Research Centre, 400016 Mumbai, India
| | - Mayank Vijayvargiya
- Junior Consultant, Department of Orthopedics, P.D Hinduja Hospital and Medical Research Centre, 400016 Mumbai, India
| |
Collapse
|
15
|
Eichenbaum G, Wilsey JT, Fessel G, Qiu QQ, Perkins L, Hasgall P, Monnot A, More SL, Egnot N, Sague J, Marcello S, Connor K, Scutti J, Christian WV, Coplan PM, Wright J, Hastings B, Katz LB, Vreeke M, Calistri-Yeh M, Faiola B, Purushothaman B, Nevelos J, Bashiri M, Christensen JB, Kovochich M, Unice K. An integrated benefit-risk assessment of cobalt-containing alloys used in medical devices: Implications for regulatory requirements in the European Union. Regul Toxicol Pharmacol 2021; 125:105004. [PMID: 34256083 DOI: 10.1016/j.yrtph.2021.105004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 05/27/2021] [Accepted: 07/09/2021] [Indexed: 11/15/2022]
Abstract
In 2017, the European Union (EU) Committee for Risk Assessment (RAC) recommended the classification of metallic cobalt (Co) as Category 1B with respect to its carcinogenic and reproductive hazard potential and Category 2 for mutagenicity but did not evaluate the relevance of these classifications for patients exposed to Co-containing alloys (CoCA) used in medical devices. CoCA are inherently different materials from Co metal from a toxicological perspective and thus require a separate assessment. CoCA are biocompatible materials with a unique combination of properties including strength, durability, and a long history of safe use that make them uniquely suited for use in a wide-range of medical devices. Assessments were performed on relevant preclinical and clinical carcinogenicity and reproductive toxicity data for Co and CoCA to meet the requirements under the EU Medical Device Regulation triggered by the ECHA re-classification (adopted in October 2019 under the 14th Adaptation to Technical Progress to CLP) and to address their relevance to patient safety. The objective of this review is to present an integrated overview of these assessments, a benefit-risk assessment and an examination of potential alternative materials. The data support the conclusion that the exposure to CoCA in medical devices via clinically relevant routes does not represent a hazard for carcinogenicity or reproductive toxicity. Additionally, the risk for the adverse effects that are known to occur with elevated Co concentrations (e.g., cardiomyopathy) are very low for CoCA implant devices (infrequent reports often reflecting a unique catastrophic failure event out of millions of patients) and negligible for CoCA non-implant devices (not measurable/no case reports). In conclusion, the favorable benefit-risk profile also in relation to possible alternatives presented herein strongly support continued use of CoCA in medical devices.
Collapse
Affiliation(s)
- Gary Eichenbaum
- Johnson & Johnson, 410 George St, New Brunswick, NJ, 08901, USA
| | - Jared T Wilsey
- Smith & Nephew, 1450 E Brooks Rd, Memphis, TN, 38116, USA
| | - Gion Fessel
- Smith & Nephew, Oberneuhofstasse 10D, 6340, Baar, Switzerland
| | - Qing-Qing Qiu
- Stryker, 2825 Airview Boulevard, Kalamazoo, MI, 49002, USA
| | - Laura Perkins
- Abbott Vascular, 3200 Lakeside Dr, Santa Clara, CA, 95054, USA
| | | | - Andrew Monnot
- Cardno ChemRisk, 235 Pine Street Suite 2300, San Francisco, CA, 94104, USA
| | - Sharlee L More
- Cardno ChemRisk, 6720 S Macadam Ave Suite 150, Portland, OR, 97219, USA
| | - Natalie Egnot
- Cardno ChemRisk, 20 Stanwix Street Suite 505, Pittsburgh, PA, 15222, USA
| | - Jorge Sague
- Stryker, 2825 Airview Boulevard, Kalamazoo, MI, 49002, USA
| | | | - Kevin Connor
- Boston Scientific, 100 Boston Scientific Way, Marlborough, MA, 01752, USA
| | - James Scutti
- Boston Scientific, 100 Boston Scientific Way, Marlborough, MA, 01752, USA
| | | | - Paul M Coplan
- Johnson & Johnson, 410 George St, New Brunswick, NJ, 08901, USA; University of Pennsylvania, Perelman School of Medicine, Philadelphia, PA, 19104, USA
| | - John Wright
- Johnson & Johnson, 410 George St, New Brunswick, NJ, 08901, USA
| | - Bob Hastings
- Johnson & Johnson, 410 George St, New Brunswick, NJ, 08901, USA
| | - Laurence B Katz
- LifeScan Global Corporation, 20 Valley Stream Parkway, Malvern, PA, 19355, USA
| | - Mark Vreeke
- Edwards Lifesciences, One Edwards Way, Irvine, CA, 92614, USA
| | | | - Brenda Faiola
- Becton Dickinson, 1 Becton Drive, Franklin Lakes, NJ, 07417, USA; Rho, Inc., 2635 E NC Hwy 54, Durham, NC, 27713, USA
| | | | - Jim Nevelos
- Stryker, 2825 Airview Boulevard, Kalamazoo, MI, 49002, USA
| | - Mehran Bashiri
- Stryker Neurovascular, 47900 Bayside Parkway, Fremont, CA, 94538, USA
| | | | - Michael Kovochich
- Cardno ChemRisk, 30 North LaSalle St Suite 3910, Chicago, Illinois, 60602-2590, USA
| | - Kenneth Unice
- Cardno ChemRisk, 20 Stanwix Street Suite 505, Pittsburgh, PA, 15222, USA.
| |
Collapse
|
16
|
Badhe RV, Akinfosile O, Bijukumar D, Barba M, Mathew MT. Systemic toxicity eliciting metal ion levels from metallic implants and orthopedic devices - A mini review. Toxicol Lett 2021; 350:213-224. [PMID: 34252509 DOI: 10.1016/j.toxlet.2021.07.004] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 06/19/2021] [Accepted: 07/07/2021] [Indexed: 12/28/2022]
Abstract
The metal/metal alloy-based implants and prostheses are in use for over a century, and the rejections, revisions, and metal particle-based toxicities were reported concurrently. Complications developed due to metal ions, metal debris, and organo-metallic particles in orthopedic patients have been a growing concern in recent years. It was reported that local and systemic toxicity caused by such released products from the implants is one of the major reasons for implant rejection and revision. Even though the description of environmental metal toxicants and safety limits for their exposure to humans were well established in the literature, an effort was not adequately performed in the case of implant-based metal toxicology. Since the metal ion concentration in serum acts as a possible indicator of the systemic toxicity, this review summarizes the reported human serum safe limits, toxic limits, and concentration range (μg/L, ppb, etc.) for mild to severe symptoms of six (cardiac, hepatic, neuro, nephron, dermal and endocrine) systemic toxicities for twelve most commonly used metallic implants. It also covers the widely used metal ion quantification techniques and systemic toxicity treatments reported.
Collapse
Affiliation(s)
- Ravindra V Badhe
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Obakanyin Akinfosile
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Divya Bijukumar
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | | | - Mathew T Mathew
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA.
| |
Collapse
|
17
|
Jenkinson MRJ, Meek RMD, Tate R, MacMillan S, Grant MH, Currie S. Cobalt-induced cardiomyopathy - do circulating cobalt levels matter? Bone Joint Res 2021; 10:340-347. [PMID: 34053230 PMCID: PMC8242681 DOI: 10.1302/2046-3758.106.bjr-2020-0414.r2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Elevated levels of circulating cobalt ions have been linked with a wide range of systemic complications including neurological, endocrine, and cardiovascular symptoms. Case reports of patients with elevated blood cobalt ions have described significant cardiovascular complications including cardiomyopathy. However, correlation between the actual level of circulating cobalt and extent of cardiovascular injury has not previously been performed. This review examines evidence from the literature for a link between elevated blood cobalt levels secondary to metal-on-metal (MoM) hip arthroplasties and cardiomyopathy. Correlation between low, moderate, and high blood cobalt with cardiovascular complications has been considered. Elevated blood cobalt at levels over 250 µg/l have been shown to be a risk factor for developing systemic complications and published case reports document cardiomyopathy, cardiac transplantation, and death in patients with severely elevated blood cobalt ions. However, it is not clear that there is a hard cut-off value and cardiac dysfunction may occur at lower levels. Clinical and laboratory research has found conflicting evidence of cobalt-induced cardiomyopathy in patients with MoM hips. Further work needs to be done to clarify the link between severely elevated blood cobalt ions and cardiomyopathy. Cite this article: Bone Joint Res 2021;10(6):340–347.
Collapse
Affiliation(s)
| | | | - Rothwell Tate
- Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow, UK
| | | | - M Helen Grant
- Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - Susan Currie
- Biomedical Engineering, University of Strathclyde, Glasgow, UK
| |
Collapse
|
18
|
Kuitunen I, Eskelinen A, Skyttä ET, Huhtala H, Artama M. Congenital anomalies in the offspring of women with total hip replacement: a nationwide register study in Finland. Hip Int 2021; 31:348-353. [PMID: 32093490 DOI: 10.1177/1120700020904689] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Few previous studies have analysed the possible teratogenic effect of maternal total hip replacement (THR) on congenital anomalies. The aim of this study was to estimate the risk of major congenital anomalies in the offspring of women with THR. Furthermore, we compared the risks based on type of implant (metal-on-metal [MoM]/non-MoM). METHODS The study population for this register-based cohort study was gathered from six Finnish national registers. All fertile-aged females who underwent THR from 1980 to 2007 and three reference females for each THR patient without THR were selected. THR operation day was the start of the follow-up for both groups. Information on pregnancies, induced abortions (IA) and congenital anomalies was gathered for the years 1987-2007 and the proportions of congenital anomalies were compared. RESULTS In the THR group, 2429 women had 256 pregnancies, 205 (80.1%) deliveries and 51 (19.9%) IAs. In the reference group, 7276 women had 1670 pregnancies, 1443 (86.4%) deliveries and 236 (13.6%) IAs. There was no difference in the incidence of major anomalies between the THR (3.5%, n = 9) and the reference group (3.6%, n = 60), p = 0.91. In the THR group, there was no difference in the risk of major anomalies between the patients with a MoM-THR (10.5%, 2/19) and those with a non-MoM (2.9%, 7/241) (OR 3.93, 95% confidence interval 0.76-20.2; p = 0.13). CONCLUSIONS Reassuringly, maternal THR does not appear to increase the risk of major congenital anomalies or pregnancies ending due to suspected foetal anomalies. Studies with larger study populations are needed to further assess the risk of anomalies in the offspring of women having MoM-THR.
Collapse
Affiliation(s)
- Ilari Kuitunen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | | | | | - Heini Huhtala
- Faculty of Social Sciences, Tampere University, Tampere, Finland
| | - Miia Artama
- Faculty of Social Sciences, Tampere University, Tampere, Finland.,The National Institute of Health and Welfare (THL), Tampere, Finland
| |
Collapse
|
19
|
Course of Metal Ions after a Revision of Malfunctioning Metal-on-Metal Total Hip Prostheses. ACTA ACUST UNITED AC 2021; 57:medicina57020115. [PMID: 33525335 PMCID: PMC7912175 DOI: 10.3390/medicina57020115] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 01/25/2021] [Accepted: 01/26/2021] [Indexed: 12/16/2022]
Abstract
The present research evaluated the course of cobalt and chromium in the blood and urine after the revision of metal-on-metal with a ceramic-on-polyethylene total hip arthroplasty. Seven patients were enrolled for hip prosthesis revision owing to ascertained damage of the implant. Metals in the blood and urine were evaluated before and after the hip revision. The double measurement before the total hip revision revealed high levels of metal ions (on average, 88.1 µg/L of cobalt in the blood, 399.0 µg/g of creatinine cobalt in the urine, 46.8 µg/L of chromium in the blood, and 129.6 µg/g of creatinine chromium in the urine at the first measurements), with an increasing trend between the first and second dosage. Within a week after the hip revision, the levels of metal ions significantly decreased by approximately half. Four to six months after the operation, the cobalt levels were found near to the reference values, whereas the chromium levels reached 25% of the values measured before the revision. The revision of malfunctioning metal-on-metal implants produced a dramatic decrease of metal ions in biological fluids, although it did not completely rescue the chromium level.
Collapse
|
20
|
Büchner M, Cook RB, Dommann-Scherrer C, Meier C, Dommann A, Wahl P. It's worth cleaning - The examination of the female taper could identify a particular cause of trunnionosis at revision 16 years after total hip arthroplasty. J Mech Behav Biomed Mater 2021; 115:104304. [PMID: 33445103 DOI: 10.1016/j.jmbbm.2020.104304] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 11/28/2020] [Accepted: 12/29/2020] [Indexed: 11/18/2022]
Abstract
Adverse reaction to metal debris (ARMD) is an issue in metal-on-metal (MoM) total hip replacements (THR). It mainly affects large-head MoM THR, whereas 28-32 mm MoM pairings are associated with low long-term revision rates. However, the bearing surface is not necessarily the only cause of metal debris. This report documents with advanced analysis of the retrievals a particular cause of trunnionosis in late failure of a small diameter MoM THR and illustrates the importance of cleaning of the taper when seating the head in THR. A 65-year-old patient was revised due to ARMD 16 years after small diameter MoM THR. Debridement and exchange of the inlay and the head had been performed through an anterior approach. While the cup and the outer surface of the head were accessible to direct analysis by an optical coordinate measuring machine, the female taper had to be analysed indirectly by measuring an imprint. Wear from the cup and the head was within expected low ranges. The analysis of the female taper identified bone fragments, which contributed to trunnionosis. Failure due to ARMD after MoM THR is not necessarily caused by the bearing, but can be due to trunnionosis. Bone fragments within the taper contact in this case highlight the importance of meticulous cleaning of the taper before seating the head, to avoid trunnionosis.
Collapse
Affiliation(s)
- Mara Büchner
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
| | - Richard B Cook
- National Centre for Advanced Tribology at Southampton, University of Southampton, Southampton, United Kingdom
| | | | - Christoph Meier
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
| | - Alex Dommann
- EMPA Swiss Federal Laboratories for Material Science and Technology, St. Gallen, Switzerland; ARTORG Centre for Biomedical Engineering Research, University of Berne, Berne, Switzerland
| | - Peter Wahl
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.
| |
Collapse
|
21
|
Pozzuoli A, Berizzi A, Crimì A, Belluzzi E, Frigo AC, Conti GD, Nicolli A, Trevisan A, Biz C, Ruggieri P. Metal Ion Release, Clinical and Radiological Outcomes in Large Diameter Metal-on-Metal Total Hip Arthroplasty at Long-Term Follow-Up. Diagnostics (Basel) 2020; 10:diagnostics10110941. [PMID: 33198180 PMCID: PMC7698262 DOI: 10.3390/diagnostics10110941] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 11/10/2020] [Accepted: 11/11/2020] [Indexed: 02/08/2023] Open
Abstract
Total hip arthroplasty (THA) with metal-on-metal (MoM) bearings have shown problems of biocompatibility linked to metal ion release at the local level causing an adverse reaction to metal debris (ARMD) and at a systemic level. The aim of this study was to evaluate clinical and radiological outcomes, and metal ion concentrations in the blood and urine of patients who underwent THA with the LIMA Met-Met hip system. Patients with ceramic-on-ceramic (CoC) bearings were included as a control group. In this study, 68 patients were enrolled: 34 with MoM THAs and 34 with CoC THAs. Patients were evaluated clinically (Harris Hip Score, SF-36) and radiologically at a median of 7.4 years after surgery. Whole blood and urinary cobalt and chromium levels were also assessed. Both types of implants were comparable in terms of clinical and functional results. Ion levels were significantly higher in the MoM group compared with CoC group 7 years after surgery. No correlations were found between metal ion levels and patient demographics, functional and radiological outcomes, and prosthesis features. Patient monitoring is thus advised to establish if prosthesis revision is necessary, especially in the case of MoM THA.
Collapse
Affiliation(s)
- Assunta Pozzuoli
- Laboratory of Musculoskeletal Pathology and Oncology, Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy
- Correspondence: (A.P.); (E.B.); Tel.: +39-0498213348 (A.P. & E.B.)
| | - Antonio Berizzi
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Alberto Crimì
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Elisa Belluzzi
- Laboratory of Musculoskeletal Pathology and Oncology, Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy
- Correspondence: (A.P.); (E.B.); Tel.: +39-0498213348 (A.P. & E.B.)
| | - Anna Chiara Frigo
- Epidemiology and Public Health Unit, Department of Cardiac Thoracic Vascular Sciences and Public Health, Biostatistics, University of Padova, Via Loredan 18, 35131 Padova, Italy;
| | - Giorgio De Conti
- Department of Radiology, University Hospital of Padova, Via Giustiniani 2, 35128 Padova, Italy;
| | - Annamaria Nicolli
- Laboratory of Industrial Toxicology, Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (A.N.); (A.T.)
| | - Andrea Trevisan
- Laboratory of Industrial Toxicology, Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (A.N.); (A.T.)
| | - Carlo Biz
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Pietro Ruggieri
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| |
Collapse
|
22
|
Taterra D, Skinningsrud B, Pękala PA, Tomaszewska IM, Marycz K, Radomski MW, Tomaszewski KA. In vitro effects of cobalt and chromium nanoparticles on human platelet function. Nanotoxicology 2020; 15:52-65. [PMID: 33147415 DOI: 10.1080/17435390.2020.1841845] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Nanoparticles (NPs) are released from orthopedic and neurosurgical prostheses and can interact with a number of blood components once in the bloodstream. Potential toxic effects of Co and Cr NPs on blood platelets have not been thoroughly investigated. The aim of this study was to analyze the effect of Co and Cr NPs on platelet function in vitro. The ability of the tested NPs to induce platelet activation and aggregation was measured using light transmission aggregometry, flow cytometry, and quartz crystal balance with dissipation (QCM-D). This was confirmed by transmission electron microscopy (TEM), scanning electron microscopy, and optical and immunofluorescence microscopy. Perfusion of QCM-D sensor crystals with platelet-rich-plasma in the presence of Co 28 nm, CoO 50 nm, Co2O3 50 nm, Co3O4 30-50nm, Cr 35-45nm, Cr2O3 60 nm NPs (0.5-5.0 µg/mL) resulted in significant changes in frequency and dissipation, indicating that these NPs caused platelet microaggregation. Transmission electron microscopy also revealed that Cr NPs led to platelet swelling and lysis. Our study shows that both Co and Cr NPs affect platelet function in vitro with two distinct mechanisms. While Co NPs result in standard platelet aggregation, Cr NPs cause both platelet aggregation and decreased platelet membrane integrity and lysis. Based on these findings, monitoring serum NP levels and platelet-mediated hemostasis can be advised in patients with metal-on-metal Co-Cr prostheses.
Collapse
Affiliation(s)
- Dominik Taterra
- Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland.,International Evidence-Based Anatomy Working Group, Krakow, Poland
| | - Bendik Skinningsrud
- Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland.,International Evidence-Based Anatomy Working Group, Krakow, Poland
| | - Przemysław A Pękala
- Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland.,International Evidence-Based Anatomy Working Group, Krakow, Poland
| | - Iwona M Tomaszewska
- Department of Medical Education, Jagiellonian University Medical College, Krakow, Poland
| | - Krzysztof Marycz
- International Institute of Translational Medicine, Malin, Poland.,Faculty of Biology and Animal Science, Department of Experimental Biology, University of Environmental and Life Sciences Wroclaw, Wroclaw, Poland.,Faculty of Veterinary Medicine, Clinic for Horses - Department for Surgery, Justus-Liebig-University, Gießen, Germany
| | - Marek W Radomski
- Department of Anatomy, Physiology and Pharmacology, College of Medicine, University of Saskatchewan, Saskatoon, Canada
| | - Krzysztof A Tomaszewski
- Department of Anatomy, Jagiellonian University Medical College, Krakow, Poland.,Faculty of Medicine and Health Sciences, Andrzej Frycz Modrzewski Krakow University, Krakow, Poland.,Scanmed St. Raphael Hospital, Krakow, Poland
| |
Collapse
|
23
|
Hall DJ, Pourzal R, Jacobs JJ. What Surgeons Need to Know About Adverse Local Tissue Reaction in Total Hip Arthroplasty. J Arthroplasty 2020; 35:S55-S59. [PMID: 32005621 PMCID: PMC7239747 DOI: 10.1016/j.arth.2020.01.016] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 01/07/2020] [Indexed: 02/01/2023] Open
Abstract
Adverse local tissue reactions (ALTRs) were first associated with patients with failed metal-on-metal surface replacements and total hip arthroplasty (THA). However, an increasing number of cases of ALTR in metal-on-polyethylene (MOP) THA patients is being reported. Clinically, ALTR appears as benign, aseptic masses or bursae in the periprosthetic tissues. Histopathologically, ALTRs are distinguished by an intense lymphocyte infiltrate, destruction of the synovial surfaces, widespread necrosis, and fibrin exudate. Tribocorrosion of modular junctions appears to be the cause of ALTR in MOP patients. The various tribocorrosion damage modes occurring at modular junctions produce metal ions and a diversity of particulates in relation to size, chemical composition, and structure. The mechanisms by which these various products of tribocorrosion lead to ALTR are still a matter of considerable research. This review clarifies what constitutes ALTR, its relationship to implant factors, and highlights current methods for diagnosis and management of patients with ALTR in the setting of MOP THA.
Collapse
Affiliation(s)
- Deborah J Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Joshua J Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| |
Collapse
|
24
|
Sengodan V, Doddihithlu S. Analysis of hematological metal element levels in orthopedic patients with implants. J Nat Sci Biol Med 2020. [DOI: 10.4103/jnsbm.jnsbm_120_19] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
25
|
Harrison-Brown M, Scholes C, Field C, McQuilty R, Farah SB, Nizam I, Kerr D, Kohan L. Limited penetration of cobalt and chromium ions into the cerebrospinal fluid following metal on metal arthroplasty: a cross-sectional analysis. Clin Toxicol (Phila) 2019; 58:233-240. [PMID: 31298064 DOI: 10.1080/15563650.2019.1636993] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Background: The purpose of this study was to determine the concentration of cobalt (Co) and chromium (Cr) ions in synovial fluid, blood plasma and cerebrospinal fluid (CSF) of patients with metal-on-metal (MoM) implants, and to assess the relationship between implant history and patient characteristics with ion concentrations in CSF.Methods: An observational, non-randomised cross-sectional study was conducted with patients presenting to a single surgeon for treatment of degenerative conditions of the hip and knee. Blood and fluid samples were collected intraoperatively and analysed for proteins and trace elements.Results: Overall, the presence of an implant was associated with significantly higher Co and Cr concentrations in plasma (controls 5-115 nmol/L Co, 5-232 nmol/L Cr; well-functioning implant recipients 5-469 nmol/L Co, 5-608 nmol/L Cr; hip revisions 6-546 nmol/L Co, 5-573 nmol/L Cr), and for Cr concentrations in CSF (controls 5-24 nmol/L; well-functioning implant recipients 6-36 nmol/L, hip revisions 7-32 nmol/L). In absolute terms, <1% of the levels observed in the joint fluid and <15% of plasma metals appeared in the CSF. Multivariable regression models suggested different transfer mechanisms of Co and Cr to the CSF, with the presence of an implant not associated with ion levels.Conclusion: The presence of MoM implants is associated with significantly higher plasma levels of Co and Cr but not CSF levels, and the CSF/plasma ratio appears to be influenced by the plasma concentration in a nonlinear fashion. Co and Cr may be transferred to the CSF by different mechanisms, and their concentrations appears dependent on other factors yet to be identified. Although higher levels of plasma ions are associated with above average CSF metal concentrations, the thresholds for neurotoxicity remain unclear and require further study.
Collapse
Affiliation(s)
| | | | | | - Robert McQuilty
- Department of Chemical Pathology, Royal Prince Alfred Hospital, Sydney, Australia
| | - Sami B Farah
- Joint Orthopaedic Centre, Sydney, Australia.,A. M. Orthopaedics, Sydney, Australia
| | | | | | | |
Collapse
|
26
|
Pijls BG, Meessen JMTA, Tucker K, Stea S, Steenbergen L, Marie Fenstad A, Mäkelä K, Cristian Stoica I, Goncharov M, Overgaard S, de la Torre JA, Lübbeke A, Rolfson O, Nelissen RGHH. MoM total hip replacements in Europe: a NORE report. EFORT Open Rev 2019; 4:423-429. [PMID: 31210979 PMCID: PMC6549109 DOI: 10.1302/2058-5241.4.180078] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
The purpose of this paper is to determine the prevalence of metal-on-metal (MoM) total hip replacement (THR) in European registries, to assess the incidence of revision surgery and to describe the national follow-up guidelines for patients with MoM THR including resurfacings. Eleven registries of the Network of Orthopaedic Registries of Europe (NORE) participated totalling 54 434 resurfacings and 58 498 large stemmed MoM THRs. The resurfacings and stemmed large head MoM had higher pooled revision rates at five years than the standard total hip arthroplasties (THA): 6.0%, 95% confidence interval (CI) 5.3 to 6.8 for resurfacings; 6.9%, 95% CI 4.4 to 9.4 for stemmed large head MoM; and 3.0%, 95% CI 2.5 to 3.6 for conventional THA. The resurfacings and stemmed large head MoM had higher pooled revision rates at ten years than the standard THAs: 12.1%, 95% CI 11.0 to 13.3 for resurfacings; 15.5%, 95% CI 9.0 to 22 for stemmed large head MoM; and 5.1%, 95% CI 3.8 to 6.4 for conventional THA. Although every national registry reports slightly different protocols for follow-up, these mostly consist of annual assessments of cobalt and chromium levels in blood and MRI (MARS) imaging.
Cite this article: EFORT Open Rev 2019;4 DOI: 10.1302/2058-5241.4.180078
Collapse
Affiliation(s)
- Bart G Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | | | - Keith Tucker
- Implant Performance Committee, England and Wales National Joint Registry, ODEP, Beyond Compliance and MHRA Expert Advisory Group for MoM Prostheses, London, UK
| | | | - Liza Steenbergen
- Dutch Arthroplasty Register (Landelijke Registratie Orthopedische Implantaten, LROI), 's- Hertogenbosch, The Netherlands
| | - Anne Marie Fenstad
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Keijo Mäkelä
- Department of Orthopedics and Traumatology, Turku University Hospital, Turku, Finland
| | | | - Maxim Goncharov
- VJRR, Russian Scientific Research Institute of Traumatology and Orthopedics, St Petersburg, Russia
| | - Søren Overgaard
- Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark
| | - Jorge Arias de la Torre
- Departament de Salut, Agència de Qualitat i Avaluació Sanitàries de Catalunya (AQuAS), Barcelona, Spain.,CIBER Epidemiología y Salud Pública (CIBERESP), Madrid, Spain.,Instituto de Biomedicina (IBIOMED). Universidad de León, León, Spain
| | - Anne Lübbeke
- Division of Orthopaedic Surgery and Traumatology, Geneva University Hospitals, Geneva, Switzerland.,Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
| | - Ola Rolfson
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
27
|
Bhalekar RM, Smith SL, Joyce TJ. Hip simulator testing of the taper-trunnion junction and bearing surfaces of contemporary metal-on-cross-linked-polyethylene hip prostheses. J Biomed Mater Res B Appl Biomater 2019; 108:156-166. [PMID: 30924612 DOI: 10.1002/jbm.b.34374] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 02/18/2019] [Accepted: 03/11/2019] [Indexed: 12/28/2022]
Abstract
Adverse reaction to metal debris released from the taper-trunnion junction of modular metal-on-polyethylene (MoP) total hip replacements (THRs) is an issue of contemporary concern. Therefore, a hip simulator was used to investigate material loss, if any, at both the articulating and taper-trunnion surfaces of five 32-mm metal-on-cross-linked-polyethylene THRs for 5 million cycles (Mc) with a sixth joint serving as a dynamically loaded soak control. Commercially available cobalt-chromium-molybdenum femoral heads articulating against cross-linked polyethylene (XLPE) acetabular liners were mounted on 12/14 titanium (Ti6Al4V) trunnions. Weight loss (mg) was measured gravimetrically and converted into volume loss (mm3 ) for heads, liners, and trunnions at regular intervals. Additionally, posttest volumetric wear measurements of the femoral tapers were obtained using a coordinate measuring machine (CMM). The surface roughness (Sa) of femoral tapers was measured posttest. After 5 Mc, the mean volumetric wear rate for XLPE liners was 2.74 ± 0.74 mm3 /Mc. The CMM measurements confirmed material loss from the femoral taper with the mean volumetric wear rate of 0.045 ± 0.024 mm3 /Mc. The Sa on the worn area of the femoral taper showed a significant increase (p < 0.001) compared with the unworn area. No other long-term hip simulator tests have investigated wear from the taper-trunnion junction of contemporary MoP THRs. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 108B:156-166, 2020.
Collapse
Affiliation(s)
- Rohan M Bhalekar
- School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, England, UK
| | - Simon L Smith
- School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, England, UK
| | - Thomas J Joyce
- School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, England, UK
| |
Collapse
|
28
|
Kovochich M, Finley BL, Novick R, Monnot AD, Donovan E, Unice KM, Fung ES, Fung D, Paustenbach DJ. Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: a state-of-the-art review. Crit Rev Toxicol 2019; 48:853-901. [DOI: 10.1080/10408444.2018.1563048] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
29
|
Reiner T, Bader N, Panzram B, Bülhoff M, Omlor G, Kretzer JP, Raiss P, Zeifang F. In vivo blood metal ion levels in patients after total shoulder arthroplasty. J Shoulder Elbow Surg 2019; 28:539-546. [PMID: 30518478 DOI: 10.1016/j.jse.2018.08.027] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 08/17/2018] [Accepted: 08/19/2018] [Indexed: 02/01/2023]
Abstract
BACKGROUND Products from metal wear have been identified as a potential cause of adverse local tissue reactions and implant failure in total hip arthroplasty. However, the role of metal ion exposure in patients after total shoulder replacement is unclear. The objective of the present study was to determine in vivo blood metal ion levels of cobalt, chromium, and titanium in patients after anatomic total shoulder arthroplasty (TSA) or reverse TSA. METHODS A consecutive series of patients after anatomic TSA or reverse TSA was evaluated retrospectively. After exclusion of patients with additional metal implants, 40 patients with unilateral anatomic TSA (n = 20) or reverse TSA (n = 20) were available for whole-blood metal ion analysis at a mean follow-up of 28 ± 9.6 months. Twenty-three healthy individuals without metal implants served as a control group. RESULTS Mean cobalt ion concentrations were 0.18 µg/L (range, 0.1-0.66 µg/L), 0.15 µg/L (range, 0.03-0.48 µg/L), and 0.11 µg/L (range, 0.03-0.19 µg/L), mean chromium ion levels were 0.48 µg/L (range, 0.17-2.41 µg/L), 0.31 µg/L (range, 0.09-1.26 µg/L), and 0.14 µg/L (range, 0.04-0.99 µg/L), and mean titanium ion concentrations were 1.31 µg/L (range, 0.75-4.52 µg/L), 0.84 µg/L (range, 0.1-1.64 µg/L), and 0.62 µg/L (range, 0.32-2.14 µg/L) in the reverse TSA group, the anatomic TSA group, and the control group, respectively. CONCLUSIONS TSA resulted in elevated metal ion levels compared with healthy controls, although overall metal ion concentrations measured in this study were relatively low. The role of local metal ion exposure in patients with total shoulder replacements should be further investigated.
Collapse
Affiliation(s)
- Tobias Reiner
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany.
| | - Nina Bader
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Benjamin Panzram
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Matthias Bülhoff
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Georg Omlor
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Jan P Kretzer
- Laboratory of Biomechanics and Implant Research, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| | - Patric Raiss
- OCM (Orthopädische Chirurgie München) Clinic for Orthopedic Surgery, Munich, Germany
| | - Felix Zeifang
- Centre for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, Heidelberg, Germany
| |
Collapse
|
30
|
Abdel Karim M, Andrawis J, Bengoa F, Bracho C, Compagnoni R, Cross M, Danoff J, Della Valle CJ, Foguet P, Fraguas T, Gehrke T, Goswami K, Guerra E, Ha YC, Klaber I, Komnos G, Lachiewicz P, Lausmann C, Levine B, Leyton-Mange A, McArthur BA, Mihalič R, Neyt J, Nuñez J, Nunziato C, Parvizi J, Perka C, Reisener MJ, Rocha CH, Schweitzer D, Shivji F, Shohat N, Sierra RJ, Suleiman L, Tan TL, Vasquez J, Ward D, Wolf M, Zahar A. Hip and Knee Section, Diagnosis, Algorithm: Proceedings of International Consensus on Orthopedic Infections. J Arthroplasty 2019; 34:S339-S350. [PMID: 30348566 DOI: 10.1016/j.arth.2018.09.018] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
31
|
Filippini T, Cilloni S, Malavolti M, Violi F, Malagoli C, Tesauro M, Bottecchi I, Ferrari A, Vescovi L, Vinceti M. Dietary intake of cadmium, chromium, copper, manganese, selenium and zinc in a Northern Italy community. J Trace Elem Med Biol 2018; 50:508-517. [PMID: 29548610 DOI: 10.1016/j.jtemb.2018.03.001] [Citation(s) in RCA: 102] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Revised: 02/26/2018] [Accepted: 03/02/2018] [Indexed: 02/06/2023]
Abstract
This study provides the dietary intakes of six trace elements (cadmium, chromium, copper, manganese, selenium and zinc), generally characterized by both nutritional and toxicological features depending on their exposure. Being diet the most relevant source of exposure to trace elements in non-professionally exposed subjects, we measured content of these trace elements in foods composing the typical Italian diet using inductively coupled plasma-mass spectrometry, and assessing dietary habits using a validated semi-quantitative food frequency questionnaire we eventually estimated dietary daily intake of trace elements in a Northern Italian community. In the 890 analyzed food samples, the main contributors to cadmium intake are cereals, vegetables and sweets, while cereals, beverages and vegetable are to primary source of manganese. The primary contributors for copper are cereals, fresh fruits and vegetables, while for chromium are beverages, cereals and meat. The main source of selenium intake are cereals and meat, followed by fish, seafood and milk and dairy products, while of zinc intake are meat, cereals, milk and dairy products. In our Italian population sample, the estimated median (interquartile range) dietary daily intakes are 5.00 (3.17-7.65), 56.70 (36.08-86.70) and 66.53 (40.04-101.32) μg/day for cadmium, chromium and selenium, and corresponding figures are 0.98 (0.61-1.49), 2.34 (1.46-3.52) and 8.50 (5.21-12.48) mg/day for copper, manganese and zinc. The estimated intakes are generally within the average intake reported in other European populations, and in such cases well above the daily dietary intakes recommended by national international agencies, avoiding the risk of excess or deficiency. The present estimated intake data can be used to examine a specific trace element of interest and would afford enhanced health protection from those trace elements characterized by both nutritional and toxicological effects.
Collapse
Affiliation(s)
- Tommaso Filippini
- CREAGEN, Environmental, Genetic and Nutritional Epidemiology Research Center, Section of Public Health - Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 287 Via Campi, 41125 Modena, Italy
| | - Silvia Cilloni
- CREAGEN, Environmental, Genetic and Nutritional Epidemiology Research Center, Section of Public Health - Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 287 Via Campi, 41125 Modena, Italy
| | - Marcella Malavolti
- CREAGEN, Environmental, Genetic and Nutritional Epidemiology Research Center, Section of Public Health - Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 287 Via Campi, 41125 Modena, Italy
| | - Federica Violi
- CREAGEN, Environmental, Genetic and Nutritional Epidemiology Research Center, Section of Public Health - Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 287 Via Campi, 41125 Modena, Italy
| | - Carlotta Malagoli
- CREAGEN, Environmental, Genetic and Nutritional Epidemiology Research Center, Section of Public Health - Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 287 Via Campi, 41125 Modena, Italy
| | - Marina Tesauro
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Italy
| | - Ilaria Bottecchi
- CREAGEN, Environmental, Genetic and Nutritional Epidemiology Research Center, Section of Public Health - Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 287 Via Campi, 41125 Modena, Italy
| | - Angela Ferrari
- CREAGEN, Environmental, Genetic and Nutritional Epidemiology Research Center, Section of Public Health - Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 287 Via Campi, 41125 Modena, Italy
| | | | - Marco Vinceti
- CREAGEN, Environmental, Genetic and Nutritional Epidemiology Research Center, Section of Public Health - Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 287 Via Campi, 41125 Modena, Italy; Department of Epidemiology, Boston University School of Public Health, Boston, MA, USA.
| |
Collapse
|
32
|
Spiegelberg BG, Lanting BA, Howard JL, Teeter MG, Naudie DD. Surface integrity of polyethylene liners following trunnionosis of a dual modular neck total hip implant. Hip Int 2018; 28:629-635. [PMID: 29756511 DOI: 10.1177/1120700018754336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND There has been a trend in the evolution of total hip arthroplasty towards increased modularity; with this increase in modularity come some potentially harmful consequences. Modularity at the neck shaft junction has been linked to corrosion, adverse reaction to metal debris and pseudotumour formation. AIM The aim of this retrieval study is to assess whether the surface integrity of the polyethylene (PE) liner is affected by metal wear debris in a single implant design series of THA revised for trunnionosis. METHODS A retrieval analysis of thirty dual-taper modular neck hip prostheses was performed; the mean time from implantation to revision was 2.7 years (1.02-6.2). PE liners were analysed using a scanning electron microscope with an energy dispersive spectrometer to assess for metal particles embedded on the liner surface. Serum metal ion levels and inflammatory markers were also analysed. RESULTS There were small numbers of metal particles present on the PE liners. The mean number of metal particles per liner was four and the particles varied in size from 0.5 µm to 122 µm mean 16 µm. All patients had elevated metal ion levels: cobalt 6.02 µg/l, chromium 1.22 µg/l, titanium 3.11 µg/l. The cobalt:chromium ratio was 7.55:1. Inflammatory markers were also marginally raised (ESR 17; CRP 10). CONCLUSION These results suggest that retention of PE liners may be reasonable when performing isolated revision of the femoral component in cases of failure at the modular neck stem junction, especially when the inner diameter of the liner is already optimised for head size and stability.
Collapse
Affiliation(s)
- Ben Gi Spiegelberg
- 1 Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, University of Western Ontario, London, ON, Canada
| | - Brent A Lanting
- 1 Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, University of Western Ontario, London, ON, Canada
| | - James L Howard
- 1 Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, University of Western Ontario, London, ON, Canada
| | - Matthew G Teeter
- 2 Medical Biophysics and Surgery, Schulich School of Medicine and Dentistry, University of Western Ontario, London, ON, Canada
| | - Douglas Dr Naudie
- 1 Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, University of Western Ontario, London, ON, Canada
| |
Collapse
|
33
|
D'Angelo F, Tanas D, Gallazzi E, Zagra L. Adverse reaction to metal debris after small-head diameter metal-on-metal total hip arthroplasty: an increasing concern. Hip Int 2018; 28:35-42. [PMID: 30755124 DOI: 10.1177/1120700018812993] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION: Failures due to adverse reaction to metal debris (ARMD) have become an area of common focus among surgeons performing hip replacements. Several authors have reported data on the prevalence of these masses, in both symptomatic and asymptomatic patients after either large-diameter head metal-on-metal (MoM) total hip arthroplasty (THA) or hip resurfacing arthroplasty, with a large variability of rate. To our knowledge, few data are reported on the association of this lesion with the use of small-head diameter MoM. METHODS: 15 hips that were revised for ARMD in small-head MoM THA were included in this study. We focused our attention on the difficulties of diagnosis and treatment and also on the histologic aspects of the harvested pathologic tissue. RESULTS: The histological examination of our cases showed a presence of lymphocytic infiltrate suggesting a delayed hypersensitivity reaction to the metal of type IV (ALVAL), but different from each other in term of the prevalence of the cellular component. Osteolysis and severe soft tissue damage were also observed. Revision resulted in remission of the lesion and successful implant. CONCLUSIONS: Our observation suggests that the evidence of ARMD should be considered even in case of small-head MoM arthroplasty and therefore these patients should be followed scrupulously with 2nd level diagnostic tools such as magnetic resonance imaging with metal artifact reduction sequence (MARS-MRI) and metal ion levels at least once. Further investigations are necessary to establish the real prevalence of this phenomenon in the whole population of small-head MoM THAs.
Collapse
Affiliation(s)
- Fabio D'Angelo
- 1 Department of Biotechnologies and Life Sciences, Division of Orthopaedics and Traumatology, University of Insubria, Italy
| | - Davide Tanas
- 1 Department of Biotechnologies and Life Sciences, Division of Orthopaedics and Traumatology, University of Insubria, Italy
| | - Enrico Gallazzi
- 2 Hip Department, I.R.C.C.S. Galeazzi Orthopaedic Institute, Milan, Italy
| | - Luigi Zagra
- 3 IRCCS Istituto Ortopedico Galeazzi, Hip Department, Milan, Italy
| |
Collapse
|
34
|
Tashjian RZ, Chalmers PN. Future Frontiers in Shoulder Arthroplasty and the Management of Shoulder Osteoarthritis. Clin Sports Med 2018; 37:609-630. [DOI: 10.1016/j.csm.2018.05.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
35
|
Pisanu F, Doria C, Andreozzi M, Bartoli M, Saderi L, Sotgiu G, Tranquilli Leali P. Pleomorphic clinical spectrum of metallosis in total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2018; 43:85-96. [PMID: 30269183 DOI: 10.1007/s00264-018-4176-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Accepted: 09/18/2018] [Indexed: 12/22/2022]
Abstract
PURPOSE To summarize the biological effects of metal debris from hip arthroplasties which characterize a polymorphic clinical spectrum of local and remote manifestation. METHODS Retrospective study. Patient, implant, and surgical characteristics were collected, including implant survival, clinical manifestations, cause of arthroplasty revision or implant failure, and peri- and intra-operative complications. The primary endpoint was implant survivorship. Hip revision arthroplasty was decided considering clinical signs and symptoms, abnormal imaging (XR, MR, TC, echotomography, scintigraphy), and blood metal ion level. An ad hoc electronic form was used to collect demographic, epidemiological, and clinical variables. In-between group comparisons of quantitative variables were performed with the Student t test and the Mann-Whitney for parametric and non-parametric variables, respectively. Logistic regression analyses were carried out to assess the relationship between clinical and radiographic characteristics and stem and cup revision. Radiographic measurements of implant positioning validity and reliability were assessed using Krippendorff's alpha reliability coefficient. The statistical software STATA version 15 (StatsCorp, TX) was used to perform statistical computations. RESULTS In this MoM THA series, the most incident cause of implant failure was ARMD in 11 out of 14 (78.6%) patients. All clinical failure manifestations, revision surgery highlights, and intra-operative findings are reported. CONCLUSIONS The local adverse reactions include lesions of different clinical relevance from small asymptomatic soft tissue lesions to dramatic osteolysis, necrosis, effusion, and growing masses which can cause secondary pathological effects. Symptoms of systemic toxicity are rarely described but may have been largely unreported in literature. Despite the extensive literature on the topic, the patient's management is still uncertain and challenging. Every metallic implant (e.g., screws, plates, spinal instrumentations) has a potential local or systemic adverse effect. Organizing a national registry of arthroplasty should be mandatory, in order to collect data about the patients, the surgery, the implanted device (with a careful post-marketing tracking), and the follow-up for all the procedures performed at a national level. The data collected in the registry will allow to analyze the implant survival and to better recognize the undesirable and sometimes unexpected effects of different biomaterials on the whole body.
Collapse
Affiliation(s)
| | - Carlo Doria
- Università degli Studi di Sassari, Sassari, Italy
| | | | | | - Laura Saderi
- Università degli Studi di Sassari, Sassari, Italy
| | | | | |
Collapse
|
36
|
Lison D, van den Brule S, Van Maele-Fabry G. Cobalt and its compounds: update on genotoxic and carcinogenic activities. Crit Rev Toxicol 2018; 48:522-539. [PMID: 30203727 DOI: 10.1080/10408444.2018.1491023] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
This article summarizes recent experimental and epidemiological data on the genotoxic and carcinogenic activities of cobalt compounds. Emphasis is on the respiratory system, but endogenous exposure from Co-containing alloys used in endoprostheses, and limited data on nanomaterials and oral exposures are also considered. Two groups of cobalt compounds are differentiated on the basis of their mechanisms of toxicity: (1) those essentially involving the solubilization of Co(II) ions, and (2) metallic materials for which both surface corrosion and release of Co(II) ions act in concert. For both groups, identified genotoxic and carcinogenic mechanisms are non-stochastic and thus expected to exhibit a threshold. Cobalt compounds should, therefore, be considered as genotoxic carcinogens with a practical threshold. Accumulating evidence indicates that chronic inhalation of cobalt compounds can induce respiratory tumors locally. No evidence of systemic carcinogenicity upon inhalation, oral or endogenous exposure is available. The scarce data available for Co-based nanosized materials does not allow deriving a specific mode of action or assessment for these species.
Collapse
Affiliation(s)
- D Lison
- Louvain Centre for Toxicology and Applied Pharmacology (LTAP), Catholic University of Louvain, Brussels, Belgium
| | - S van den Brule
- Louvain Centre for Toxicology and Applied Pharmacology (LTAP), Catholic University of Louvain, Brussels, Belgium
| | - G Van Maele-Fabry
- Louvain Centre for Toxicology and Applied Pharmacology (LTAP), Catholic University of Louvain, Brussels, Belgium
| |
Collapse
|
37
|
Ferko MA, Catelas I. Effects of metal ions on caspase-1 activation and interleukin-1β release in murine bone marrow-derived macrophages. PLoS One 2018; 13:e0199936. [PMID: 30138321 PMCID: PMC6107125 DOI: 10.1371/journal.pone.0199936] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Accepted: 06/15/2018] [Indexed: 02/07/2023] Open
Abstract
Ions released from metal implants have been associated with adverse tissue reactions and are therefore a major concern. Studies with macrophages have shown that cobalt, chromium, and nickel ions can activate the NLRP3 inflammasome, a multiprotein complex responsible for the activation of caspase-1 (a proteolytic enzyme converting pro-interleukin [IL]-1β to mature IL-1β). However, the mechanism(s) of inflammasome activation by metal ions remain largely unknown. The objectives of the present study were to determine if, in macrophages: 1. caspase-1 activation and IL-1β release induced by metal ions are oxidative stress-dependent; and 2. IL-1β release induced by metal ions is NF-κB signaling pathway-dependent. Lipopolysaccharide (LPS)-primed murine bone marrow-derived macrophages (BMDM) were exposed to Co2+ (6-48 ppm), Cr3+ (100-500 ppm), or Ni2+ (12-96 ppm), in the presence or absence of a caspase-1 inhibitor (Z-WEHD-FMK), an antioxidant (L-ascorbic acid [L-AA]), or an NF-κB inhibitor (JSH-23). Culture supernatants were analyzed for caspase-1 by western blotting and/or IL-1β release by ELISA. Immunoblotting revealed the presence of caspase-1 (p20 subunit) in supernatants of BMDM incubated with Cr3+, but not with Ni2+ or Co2+. When L-AA (2 mM) was present with Cr3+, the caspase-1 p20 subunit was undetectable and IL-1β release decreased down to the level of the negative control, thereby demonstrating that caspase-1 activation and IL-1β release induced by Cr3+ was oxidative stress-dependent. ELISA demonstrated that Cr3+ induced the highest release of IL-1β, while Co2+ had no or limited effects. In the presence of Ni2+, the addition of L-AA (2 mM) also decreased IL-1β release, below the level of the negative control, suggesting that IL-1β release induced by Ni2+ was also oxidative stress-dependent. Finally, when present during both priming with LPS and activation with Cr3+, JSH-23 blocked IL-1β release, demonstrating NF-κB involvement. Overall, this study showed that while both Cr3+ and Ni2+ may be inducing inflammasome activation, Cr3+ is likely a more potent activator, acting through oxidative stress and the NF-κB signaling pathway.
Collapse
Affiliation(s)
| | - Isabelle Catelas
- Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada
- Department of Surgery, University of Ottawa, Ottawa, Ontario, Canada
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
38
|
Kapnisis K, Constantinou M, Kyrkou M, Nikolaou P, Anayiotos A, Constantinides G. Nanotribological response of a-C:H coated metallic biomaterials: the cases of stainless steel, titanium, and niobium. J Appl Biomater Funct Mater 2018; 16:230-240. [PMID: 29974806 DOI: 10.1177/2280800018782840] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Background Wear and corrosion have been identified as two of the major forms of medical implant failures. This study aims to improve the surface, protective and tribological characteristics of bare metals used for medical implants, so as to improve scratch resistance and increase lifetime. Methods Hydrogenated amorphous carbon (a-C:H) films were deposited, using plasma enhanced chemical vapor deposition (PECVD), on stainless steel (SS), titanium (Ti) and niobium (Nb) metal plates. Nanomechanical and nanotribological responses were investigated before and after a-C:H deposition. Film thickness and density were quantified through X-ray reflectivity, and surface morphology before and after deposition were measured using atomic force microscopy, whereas the tribomechanical characteristics were probed using instrumented indentation. Results and conclusions Films of approximately 40 nm in thickness and density of 1.7 g/cm3 were deposited. The a-C:H films reduce the roughness and coefficient of friction while improving the tribomechanical response compared with bare metals for Ti, SS and Nb plates. The very good tribomechanical properties of a-C:H make it a promising candidate material for protective coating on metallic implants.
Collapse
Affiliation(s)
- Konstantinos Kapnisis
- 1 Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Lemesos, Cyprus
| | - Marios Constantinou
- 1 Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Lemesos, Cyprus.,2 Research Unit for Nanostructured Materials Systems, Cyprus University of Technology, Lemesos, Cyprus
| | - Maria Kyrkou
- 1 Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Lemesos, Cyprus
| | - Petros Nikolaou
- 1 Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Lemesos, Cyprus.,2 Research Unit for Nanostructured Materials Systems, Cyprus University of Technology, Lemesos, Cyprus
| | - Andreas Anayiotos
- 1 Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Lemesos, Cyprus
| | - Georgios Constantinides
- 1 Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Lemesos, Cyprus.,2 Research Unit for Nanostructured Materials Systems, Cyprus University of Technology, Lemesos, Cyprus
| |
Collapse
|
39
|
Persson A, Eisler T, Bodén H, Krupic F, Sköldenberg O, Muren O. Revision for Symptomatic Pseudotumor After Primary Metal-on-Polyethylene Total Hip Arthroplasty with a Standard Femoral Stem. J Bone Joint Surg Am 2018; 100:942-949. [PMID: 29870445 DOI: 10.2106/jbjs.17.00616] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Pseudotumor formation following total hip arthroplasty (THA) is a well-known complication mainly associated with metal-on-metal (MoM) bearings and taper corrosion on modular-neck femoral stems. The purpose of this study was to determine the prevalence of revision surgery for symptomatic pseudotumors in a large cohort of patients treated with primary THA with a standard stem and a non-MoM articulation. METHODS We included 2,102 patients treated with a total of 2,446 THAs from 1999 until May 2016 in a prospective, observational cohort study. All patients underwent THA with the same uncemented, non-modular-neck femoral stem and metal-on-polyethylene (MoP) (n = 2,409) or ceramic-on-polyethylene (n = 37) articulation. All patients were followed by means of a combination of surgical and medical chart review, follow-up visits, and the Swedish Hip Arthroplasty Register. Metal artifact reduction sequence magnetic resonance imaging (MARS MRI) was used for diagnosis of the pseudotumors, and serum metal ion levels and inflammatory marker levels were measured for all patients who underwent a revision due to pseudotumor. RESULTS The prevalence of revision for symptomatic pseudotumor formation was 0.5% (13 cases) at a mean follow-up time of 7 years. The incidence rate was 0.9 case per 1,000 person-years. All 13 revisions were done in patients with an MoP articulation. CONCLUSIONS This study demonstrated a 0.5% prevalence of revision due to symptomatic pseudotumor formation in a cohort of patients who underwent THA with a non-MoM construct. Surgeons should be aware that symptomatic pseudotumor formation requiring revision surgery is a tangible complication even after standard MoP THA. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Anders Persson
- Department of Orthopaedics, Danderyd University Hospital, Karolinska Institute at Danderyd University Hospital, Stockholm, Sweden
| | - Thomas Eisler
- Department of Orthopaedics, Danderyd University Hospital, Karolinska Institute at Danderyd University Hospital, Stockholm, Sweden
| | - Henrik Bodén
- Department of Orthopaedics, Danderyd University Hospital, Karolinska Institute at Danderyd University Hospital, Stockholm, Sweden
| | - Ferid Krupic
- Department of Orthopaedics and Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Olof Sköldenberg
- Department of Orthopaedics, Danderyd University Hospital, Karolinska Institute at Danderyd University Hospital, Stockholm, Sweden
| | - Olav Muren
- Department of Orthopaedics, Danderyd University Hospital, Karolinska Institute at Danderyd University Hospital, Stockholm, Sweden
| |
Collapse
|
40
|
Comparison of Postoperative Complications Following Metal-on-Metal Total Hip Arthroplasty With Other Hip Bearings in Medicare Population. J Arthroplasty 2018; 33:1826-1832. [PMID: 29510952 DOI: 10.1016/j.arth.2018.01.066] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2016] [Revised: 01/18/2018] [Accepted: 01/25/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The use of metal-on-metal (MoM) hip bearings has declined in the recent years due to strong evidence of their high complication rates and early failure. Hip implants with highly cross-linked polyethylene liners and ceramic bearings have become the modern implants of choice. We sought to determine if MoM implants are associated with higher complication and revision rates when compared to other hip bearings in the Medicare population. METHODS We retrospectively reviewed a Medicare database (2005-2011) for patients who underwent a primary total hip arthroplasty with a MoM, metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), or ceramic-on-ceramic (CoC) implant (minimum 2 years of follow-up). Patient comorbidities and medical/surgical complication rates were analyzed at various time points postoperatively. RESULTS We identified 288,118 patients, including 81,520 patients with a MoM implant, 162,881 with MoP, 33,819 with CoP, and 9898 with CoC implant. Surgical complication rates were higher for MoM implants including infection, osteolysis/polywear, mechanical complications, and need for hip irrigation and debridement. Overall revision rates were significantly higher for MoM implants (5.28%) compared to MoP (4.28%, odds ratio [OR] 1.26, P < .001) and CoP (3.52%, OR 1.55, P < .001) but only by one to two percent. MoM revision rates were similar to CoC implants (4.94%, OR 1.00, P = .096). CONCLUSIONS MoM implants were associated with higher revision rates (5.28%) compared to MoP (4.28%) and CoP (3.52%) implants in the Medicare population. Both complication and revision rates were comparable to CoC implants.
Collapse
|
41
|
Sessa G, Testa G, Gioitta Iachino S, Costarella L, Puma Pagliarello C, Ferrante M, Grasso A, Pavone V. Potential presence of metals in patients treated with metal-metal coupling prostheses for hip arthroplasty at 7 and 10 years of follow-up. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2018; 28:637-643. [PMID: 29356908 DOI: 10.1007/s00590-018-2129-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Accepted: 01/07/2018] [Indexed: 10/18/2022]
Abstract
BACKGROUND Beginning in 2008, metal-on-metal prostheses have been in the spotlight owing to much higher revision rates than expected. Adverse local tissue reactions have been well described in the literature as potential complications. METHODS Between 2012 and 2013, 13 patients with metal-on-metal total hip replacements were evaluated clinically and radiologically and with laboratory samples. The same tests were repeated between 2015 and 2016 on eight patients to assess any changes. In the laboratory assessment, we searched for chromium, cobalt, molybdenum, and nickel in blood and urine samples over 24 h. RESULTS Clinical assessment has shown good score in all patients except one. On a second examination, between 2015 and 2016, all patients obtained results similar to those obtained in the first assessment, except a patient, who reported a recent fall. In the radiological assessment between 2012 and 2013, results were optimal, apart from a case of aseptic mobilization. The patients reassessed 3 years after the first examination showed radiological results similar to those previously obtained, apart from a patient, who showed signals of mobilization. Metal levels found in their blood decreased in most cases after 3 years. Urine levels of nickel increased in five subjects, and chromium levels increased in four, but levels of cobalt and molybdenum decreased in four patients. CONCLUSION It could be hypothesized that the decreasing trend of metal ion levels is associated with a stable wear status. On the contrary, a progressive increase in metal ion levels must be considered as early proof of implant loosening.
Collapse
Affiliation(s)
- Giuseppe Sessa
- Department of General Surgery and Medical Surgical Specialties, Section of Orthopaedics and Traumatology, University Hospital Policlinico-Vittorio Emanuele, University of Catania, Catania, Italy
| | - Gianluca Testa
- Department of General Surgery and Medical Surgical Specialties, Section of Orthopaedics and Traumatology, University Hospital Policlinico-Vittorio Emanuele, University of Catania, Catania, Italy.
| | - Salvatore Gioitta Iachino
- Department of General Surgery and Medical Surgical Specialties, Section of Orthopaedics and Traumatology, University Hospital Policlinico-Vittorio Emanuele, University of Catania, Catania, Italy
| | - Luciano Costarella
- Department of General Surgery and Medical Surgical Specialties, Section of Orthopaedics and Traumatology, University Hospital Policlinico-Vittorio Emanuele, University of Catania, Catania, Italy
| | - Calogero Puma Pagliarello
- Department of General Surgery and Medical Surgical Specialties, Section of Orthopaedics and Traumatology, University Hospital Policlinico-Vittorio Emanuele, University of Catania, Catania, Italy
| | - Margherita Ferrante
- Department of Medical, Surgical and Advanced Technologies 'G.F. Ingrassia', University of Catania, Catania, Italy
| | - Alfina Grasso
- Department of Medical, Surgical and Advanced Technologies 'G.F. Ingrassia', University of Catania, Catania, Italy
| | - Vito Pavone
- Department of General Surgery and Medical Surgical Specialties, Section of Orthopaedics and Traumatology, University Hospital Policlinico-Vittorio Emanuele, University of Catania, Catania, Italy
| |
Collapse
|
42
|
Sonntag R, Feige K, Dos Santos CB, Kretzer JP. Hard Chrome-Coated and Fullerene-Doped Metal Surfaces in Orthopedic Bearings. MATERIALS 2017; 10:ma10121449. [PMID: 29261128 PMCID: PMC5744384 DOI: 10.3390/ma10121449] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 12/05/2017] [Accepted: 12/19/2017] [Indexed: 12/12/2022]
Abstract
Metal-on-metal bearings for total hip replacements have been introduced as an alternative to polyethylene in young and more active patients. These have, however, been shown to be prone to implant malpositioning and have been limited by some specific design features. In that context, coatings present an option to increase wear resistance by keeping the high fracture strength of the metal substrate. A custom-made electroplating setup was designed for the coating of CoCr substrates using (a) an industrial standard chromium electrolyte; (b) a custom-made hexavalent chromium (Cr6+) electrolyte with a reduced chromium trioxide (CrO3) content, both without solid additives and (c) with the addition of fullerene (C60) nanoparticles; and (d) a trivalent chromium (Cr3+) electrolyte with C60 addition. All coatings showed an increase in microhardness compared with the metal substrate. Trivalent coatings were thinner (10 µm) than the hexavalent coatings (23–40 µm) and resulted in increased roughness and crack density. Wear was found to be reduced for the hexavalent chromium coatings by 70–84% compared with the CoCr–CoCr reference bearing while the trivalent chromium coating even increased wear by more than 300%. The addition of fullerenes to the electrolyte did not show any further tribological effect.
Collapse
Affiliation(s)
- Robert Sonntag
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany.
| | - Katja Feige
- Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Department Electroplating, 70569 Stuttgart, Germany.
| | - Claudia Beatriz Dos Santos
- Institute of Industrial Manufacturing and Management IFF, University of Stuttgart, 70569 Stuttgart, Germany.
| | - Jan Philippe Kretzer
- Laboratory of Biomechanics and Implant Research, Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany.
| |
Collapse
|
43
|
Ho JH, Leikin JB, Dargan PI, Archer JRH, Wood DM, Brent J. Metal-on-Metal Hip Joint Prostheses: a Retrospective Case Series Investigating the Association of Systemic Toxicity with Serum Cobalt and Chromium Concentrations. J Med Toxicol 2017; 13:321-328. [PMID: 28900863 PMCID: PMC5711759 DOI: 10.1007/s13181-017-0629-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 08/09/2017] [Accepted: 08/17/2017] [Indexed: 12/19/2022] Open
Abstract
INTRODUCTION There have been concerns about prosthesis failure and the potential for systemic toxicity due to release of cobalt and chromium from metal-on-metal hip joint prostheses (MoM-HP). There is conflicting evidence on whether there is a correlation between higher cobalt and chromium concentrations and systemic toxicity. METHODS We undertook a retrospective review of consecutive patients with MoM-HP referred for outpatient review in toxicology clinics in London, UK, and in the USA recorded in the Toxicology Investigators Consortium (ToxIC) Registry from June 2011 to June 2015. RESULTS Thirty-one cases were identified; the median (IQR) serum cobalt concentration was 10.0 (3.8-32.8) mcg/L, and the median (IQR) serum chromium concentration was 6.9 (3.7-18.7) mcg/L. Twenty-three (74.2%) had symptoms, most commonly lethargy, hearing loss, and tinnitus. The odds ratios of symptomatic/asymptomatic patients for metal ion concentrations above/below 7 mcg/L were 1.87 (95% CI 0.37-9.57, p = 0.45) and 0.60 (95% CI 0.10-3.50, p = 0.57) for cobalt and chromium, respectively. Two (6.5%) patients with systemic cobalt toxicity had median (IQR) serum cobalt concentrations significantly higher than those without systemic features (630.4 [397.6-863.2] mcg/L versus 9.8 [2.9-16.4] mcg/L; p = 0.017). However, overall, there were no differences between cobalt (p = 0.38) or chromium (p = 0.92) concentrations between symptomatic and asymptomatic patients and no clinical features or investigation results correlated with cobalt or chromium concentration. CONCLUSION Two (6.5%) of 31 individuals referred for assessment of MoM-HP were diagnosed with systemic cobalt toxicity. However, despite a high prevalence of reported symptoms, neither symptoms nor investigation results correlated with serum cobalt or chromium concentrations.
Collapse
Affiliation(s)
- James H Ho
- Clinical Toxicology, Guy's and St Thomas' NHS Foundation Trust and King's Health Partners, Westminster Bridge Road, London, SE1 7EH, UK
| | - Jerrold B Leikin
- Medical Toxicology, Glenbrook Hospital, NorthShore University Health System-OMEGA, Glenview, IL, USA
- Pritzker School of Medicine, University of Chicago, Chicago, IL, USA
| | - Paul I Dargan
- Clinical Toxicology, Guy's and St Thomas' NHS Foundation Trust and King's Health Partners, Westminster Bridge Road, London, SE1 7EH, UK.
- Faculty of Life Sciences and Medicine, King's College London, London, UK.
| | - John R H Archer
- Clinical Toxicology, Guy's and St Thomas' NHS Foundation Trust and King's Health Partners, Westminster Bridge Road, London, SE1 7EH, UK
- Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - David M Wood
- Clinical Toxicology, Guy's and St Thomas' NHS Foundation Trust and King's Health Partners, Westminster Bridge Road, London, SE1 7EH, UK
- Faculty of Life Sciences and Medicine, King's College London, London, UK
| | - Jeffrey Brent
- School of Medicine, University of Colorado, Aurora, CO, USA
| |
Collapse
|
44
|
Fung ES, Monnot A, Kovochich M, Unice KM, Tvermoes BE, Galbraith D, Finley BL, Paustenbach DJ. Characteristics of Cobalt-Related Cardiomyopathy in Metal Hip Implant Patients: An Evaluation of 15 Published Reports. Cardiovasc Toxicol 2017; 18:206-220. [PMID: 29188590 DOI: 10.1007/s12012-017-9433-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Over 300,000 hip replacements occurred in the USA in 2010, and the frequency is likely increasing annually. Blood Cobalt (Co) concentrations in patients with well-functioning cobalt-chromium (Co-Cr) hip implants are usually elevated above background concentrations relative to the general population. Excessive Co exposure, in rare cases, can result in cardiomyopathy. The purpose of this review was to identify cases of cardiomyopathy in metal-containing hip implant patients and to evaluate the possible cause of each patient's cardiomyopathy. We evaluated 15 cases published between 2009 and 2016, and, based on a review of the preexisting risk factors, blood Co concentrations, and histopathological information published for each patient, they were stratified into one of four categories regarding the association between Co exposure and the development of cardiomyopathy: (1) Co was causal (five cases); (2) Co was contributory (two cases); (3) Co was possibly contributory (six cases); and (4) Co was non-causal (two cases). In all 15 cases, blood Co concentrations (14-6521 μg/L) were elevated beyond levels associated with the majority of metal-containing implant patients (0.1-10 μg/L), and, in many cases, there was evidence of a malfunctioning implant. The data indicate that individuals with well-functioning implants, even those with preexisting risk factors, are at no risk of developing cardiac effects. We conclude that blood Co measurements are informative, but should be interpreted with caution, and in context of other factors evaluated in this analysis. The mere presence of elevated Co is not sufficient to indicate causation for a patient's cardiomyopathy.
Collapse
Affiliation(s)
- Ernest S Fung
- Cardno ChemRisk, 65 Enterprise, Suite 150, Aliso Viejo, CA, 92656, USA
| | - Andrew Monnot
- Cardno ChemRisk, 101 2nd St. Suite 700, San Francisco, CA, 94105, USA
| | - Michael Kovochich
- Cardno ChemRisk, 65 Enterprise, Suite 150, Aliso Viejo, CA, 92656, USA.
| | - Kenneth M Unice
- Cardno ChemRisk, 20 Stanwix St. Suite 505, Pittsburgh, PA, 15222, USA
| | - Brooke E Tvermoes
- Cardno ChemRisk, 4940 Pearl East Circle Suite 100, Boulder, CO, 80301, USA.,IBM, Boulder, CO, USA
| | - David Galbraith
- Cardno ChemRisk, 101 2nd St. Suite 700, San Francisco, CA, 94105, USA
| | - Brent L Finley
- Cardno ChemRisk, 231 Front St. Suite 212, Brooklyn, NY, 11201, USA
| | | |
Collapse
|
45
|
Granchi D, Savarino LM, Ciapetti G, Baldini N. Biological effects of metal degradation in hip arthroplasties. Crit Rev Toxicol 2017; 48:170-193. [PMID: 29130357 DOI: 10.1080/10408444.2017.1392927] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Metals and metal alloys are the most used materials in orthopedic implants. The focus is on total hip arthroplasty (THA) that, though well tolerated, may be associated with local and remote adverse effects in the medium-long term. This review aims to summarize data on the biological consequences of the metal implant degradation that have been attributed predominantly to metal-on-metal (MoM) THA. Local responses to metals consist of a broad clinical spectrum ranging from small asymptomatic tissue lesions to severe destruction of bone and soft tissues, which are designated as metallosis, adverse reactions to metal debris (ARMD), aseptic lymphocytic vasculitis associated lesion (ALVAL), and pseudotumors. In addition, the dissemination of metal particles and ions throughout the body has been associated with systemic adverse effects, including organ toxicity, cancerogenesis, teratogenicity, and immunotoxicity. As proved by the multitude of studies in this field, metal degradation may increase safety issues associated with THA, especially with MoM hip systems. Data collection regarding local, systemic and long-term effects plays an essential role to better define any safety risks and to generate scientifically based recommendations.
Collapse
Affiliation(s)
- Donatella Granchi
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Lucia Maria Savarino
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Gabriela Ciapetti
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Nicola Baldini
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy.,b Department of Biomedical and Neuromotor Science , University of Bologna , Bologna , Italy
| |
Collapse
|
46
|
Fortmann C, Göen T, Krüger M, Ure BM, Petersen C, Kübler JF. Trace metal release after minimally-invasive repair of pectus excavatum. PLoS One 2017; 12:e0186323. [PMID: 29023602 PMCID: PMC5638555 DOI: 10.1371/journal.pone.0186323] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2017] [Accepted: 09/18/2017] [Indexed: 11/18/2022] Open
Abstract
Background Several studies have shown a high incidence of metal allergy after minimally-invasive repair of pectus excavatum (MIRPE). We postulated that MIRPE is associated with a significant release of trace metal ions, possibly causing the allergic symptoms. Methods We evaluated the concentration with chromium, cobalt and nickel in blood, urine and tissue in patients prior to MIRPE and in patients who underwent an explantation of the stainless-steel bar(s) after three years. Results Our study group consisted of 20 patients (mean age 19 years) who had bar explantation and our control group included 20 patients (mean age 16 years) prior to MIRPE. At the time of bar removal we detected significantly elevated concentrations of chromium and nickel in the tissue compared to patients prior to the procedure (p<0,001). We also found a significant increase in the levels of chromium in urine and nickel in blood in patients three years post MIRPE (p<0,001). Four patients temporarily developed symptoms of metal allergy, all had elevated metal values in blood and urine at explantation. Conclusions Minimally-invasive repair of pectus excavatum can lead to a significant trace metal exposure.
Collapse
Affiliation(s)
- Caroline Fortmann
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
- * E-mail:
| | - Thomas Göen
- Institute and Outpatient Clinic of Occupational, Social and Environmental Medicine, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany
| | - Marcus Krüger
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Benno M. Ure
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Claus Petersen
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| | - Joachim F. Kübler
- Department of Pediatric Surgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|
47
|
Ochi H, Baba T, Homma Y, Matsumoto M, Watari T, Ozaki Y, Kobayashi H, Kaneko K. Total hip arthroplasty via the direct anterior approach with a dual mobility cup for displaced femoral neck fracture in patients with a high risk of dislocation. SICOT J 2017; 3:56. [PMID: 28984572 PMCID: PMC5629867 DOI: 10.1051/sicotj/2017048] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Accepted: 08/30/2017] [Indexed: 02/06/2023] Open
Abstract
Introduction: Although total hip arthroplasty (THA) is superior to bipolar hemiarthroplasty (BHA) for displaced femoral neck fracture in terms of hip pain, function and reoperation rate, THA has a higher rate of dislocation. The direct anterior approach (DAA) and a dual mobility cup (DMC) are associated with lower rates of dislocation. The aim of this study was to investigate the outcomes of THA compared with BHA, and in those patients who had a THA we investigated those with a DMC (DMC-THA) and compared them with those had a single conventional cup (Single cup-THA). Materials: A total of 89 patients living independently were included between 2009 and 2015. We assessed patient characteristics, peri- and post-operative outcomes, walking ability and one-year mortality. Adjusted odds ratios (Adjusted ORs) were estimated for decrease of walking ability and one-year mortality using a logistic regression model with adjustment for potential confounders such as age, neuromuscular diseases with weakness, duration of surgery, perioperative blood loss and preoperative walking ability. Results: BHA (20 patients) versus THA (69 patients): There was no significant difference in the walking ability in either group. Multivariable logistic regression analysis demonstrated a significant association with one-year mortality in both groups [THA Adjusted ORs 0.088 (95% CI 0.0007–0.69); p = 0.020]. Single cup-THA (36 patients) versus DMC-THA (33 patients): The DMC-THA group had significantly greater age and more patients with neuromuscular diseases with weakness compared with the Single cup-THA group. Multivariable logistic regression analysis demonstrated no significant difference in the decrease of walking ability and in the one-year mortality between the groups. There were no post operative dislocations in any group. Discussion: THA via the DAA is one of the best treatments for displaced femoral neck fracture with a low risk of dislocation. THA via the DAA with a DMC is a safe and effective treatment for the patients with a high risk of dislocation.
Collapse
Affiliation(s)
- Hironori Ochi
- Department of Orthopedic Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan
| | - Tomonori Baba
- Department of Orthopedic Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan
| | - Yasuhiro Homma
- Department of Orthopedic Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan
| | - Mikio Matsumoto
- Department of Orthopedic Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan
| | - Taiji Watari
- Department of Orthopedic Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan
| | - Yu Ozaki
- Department of Orthopedic Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan
| | - Hideo Kobayashi
- Department of Orthopedic Surgery, Sanikukai Hospital, 3-20-2 Taihei, Sumida-ku, Tokyo 130-0012, Japan
| | - Kazuo Kaneko
- Department of Orthopedic Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan
| |
Collapse
|
48
|
Campbell P, Ebramzadeh E. ARMD and Presumed Dangerous!: Commentary on an article by Gulraj S. Matharu, BSc(Hons), MRCS, MRes, et al.: "Blood Metal Ion Thresholds to Identify Patients with Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris. An External Multicenter Validation Study of Birmingham Hip Resurfacing and Corail-Pinnacle Implants". J Bone Joint Surg Am 2017; 99:e100. [PMID: 28926394 DOI: 10.2106/jbjs.17.00701] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
49
|
Adverse reaction to metal debris in a consecutive series of DUROM™ hip resurfacing: pseudotumour incidence and metal ion concentration. Hip Int 2017; 27:343-348. [PMID: 28218371 DOI: 10.5301/hipint.5000468] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/08/2016] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The aim of this study was to evaluate the incidence of adverse reactions to metal debris (ARMD) in a consecutive series of DUROM™ Hip Resurfacing Arthroplasty (HRA) at mid-term follow-up. METHODS Between October 2003 and March 2007 a total of 134 consecutive DUROM™ HRA in 121 patients were performed at our institution. Follow-up could be obtained in 101 unrevised patients (83%) at a mean time of 8.51 ± 0.97 years postoperatively and included patient-related outcome measurement, plain radiographs, MARS-MRI as well as whole blood metal ion assessment. RESULTS 17 (16.5%) out of 103 hips revealed pseudotumour occurrence in MRI investigation, 1 (10.6%) with a diameter of ≥2 cm. Higher incidence of pseudotumours was found patients with femoral component size <50 mm. 38 patients had elevated cobalt levels, 36 of them (35%) in the range of 2-7 μg/l and 2 patients (1.9%) at a rate of >7 μg/l. In contrast to cobalt determination, only elevated chromium values showed a positive association with pseudotumour occurrence and size. DISCUSSION A significant proportion of patients developed pseudotumours and metal ion elevation in a consecutive cohort of DUROM™ HRA after mid-term follow-up. The incidence, however, seems not to differ from results of other well performing resurfacing brands; clinical relevance of our findings is unclear. Regarding potential local as well as systemic effects of metal particle release, close follow-up of patients is essential, even with clinically well-performing implants.
Collapse
|
50
|
Li D, Tong W, Liu D, Zou Y, Zhang C, Xu W. Astaxanthin mitigates cobalt cytotoxicity in the MG-63 cells by modulating the oxidative stress. BMC Pharmacol Toxicol 2017; 18:58. [PMID: 28738843 PMCID: PMC5525213 DOI: 10.1186/s40360-017-0166-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2016] [Accepted: 07/14/2017] [Indexed: 12/11/2022] Open
Abstract
Background With the re-popularity of metal-on-metal (MoM) bearing in recent years, the cobalt toxicity has been a cause for concern in the total hip replacement surgery by both physicians and patients. Methods MG-63 cell line was cultured in vitro and incubated with cobalt (II) chloride (CoCl2) and/or with astaxanthin (ASX) for 24 h. MTT assay was conducted to evaluate the cell viability after cobalt exposure and ASX treatment. Fluorescence-activated cell sorting (FACS) analysis was performed to examine the reactive oxygen species (ROS) level. Quantitative real-time polymerase chain reaction (PCR) was adopted to determine the mRNA levels of related targets. And western blot analysis was used to examine the protein expressions. One-way ANOVA with posttest Newman-Keuls multiple comparisons was adopted to analysis all the obtained data. Results In the current study, ASX exhibited significant protective effect against the Co(II)-induced cytotoxicity in MG-63 cell line. We also found that ASX protected the cells against Co-induced apoptosis by regulating the expression of Bcl-2 family proteins. Besides, heme oxygenase 1 (HO-1) could be activated by Co exposure; ASX treatment significantly inhibited HO-1 activation, suppressing the oxidative stress induced by Co exposure. Moreover, c-Jun N-terminal Kinase (JNK) phosphorylation was shown to participate in the signaling pathway of the protective effect of ASX. However, knockdown of JNK expression by siRNA transfection or JNK inhibitor SP600125 treatment did not affect the protective effect of ASX against cobalt cytotoxicity in MG-63 cells. Conclusions ASX mitigated cobalt cytotoxicity in the MG-63 cells by modulating the oxidative stress. And ASX could be a promising therapy against cobalt toxicity in the hip articulation surgery. Electronic supplementary material The online version of this article (doi:10.1186/s40360-017-0166-1) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Dahe Li
- Department of Orthopedics, The Eighty-eighth Military Hospital, Tai'an, 271000, China
| | - Wenwen Tong
- Department of Orthopedics, Shanghai Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Denghui Liu
- Department of Orthopedics, Shanghai Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Yuming Zou
- Department of Orthopedics, Shanghai Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Chen Zhang
- Department of Orthopedics, Shanghai Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Weidong Xu
- Department of Orthopedics, Shanghai Changhai Hospital, Naval Medical University, Shanghai, 200433, China.
| |
Collapse
|