1
|
Wårdell K, Klint E, Milos P, Richter J. One-Insertion Stereotactic Brain Biopsy Using In Vivo Optical Guidance-A Case Study. Oper Neurosurg (Hagerstown) 2023; 25:176-182. [PMID: 37083519 PMCID: PMC10313274 DOI: 10.1227/ons.0000000000000722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 02/21/2023] [Indexed: 04/22/2023] Open
Abstract
BACKGROUND Stereotactic neurosurgical brain biopsies are afflicted with risks of inconclusive results and hemorrhage. Such complications can necessitate repeated trajectories and prolong surgical time. OBJECTIVE To develop and introduce a 1-insertion stereotactic biopsy kit with direct intraoperative optical feedback and to evaluate its applicability in 3 clinical cases. METHODS An in-house forward-looking probe with optical fibers was designed to fit the outer cannula of a side-cutting biopsy kit. A small aperture was made at the tip of the outer cannula and the edges aligned with the optical probe inside. Stereotactic biopsies were performed using the Leksell Stereotactic System. Optical signals were measured in millimeter steps along the preplanned trajectory during the insertion. At the region with the highest 5-aminolevulinic acid (5-ALA)-induced fluorescence, the probe was replaced by the inner cannula, and tissue samples were taken. The waiting time for pathology diagnosis was noted. RESULTS Measurements took 5 to 10 minutes, and the surgeon received direct visual feedback of intraoperative 5-ALA fluorescence, microcirculation, and tissue gray-whiteness. The 5-ALA fluorescence corroborated with the pathological findings which had waiting times of 45, 50, and 75 minutes. Because only 1 trajectory was required and the patient could be prepared for the end of surgery immediately after sampling, this shortened the total surgical time. CONCLUSION A 1-insertion stereotactic biopsy procedure with real-time optical guidance has been presented and successfully evaluated in 3 clinical cases. The method can be modified for frameless navigation and thus has great potential to improve safety and diagnostic yield for both frameless and frame-based neurosurgical biopsy procedures.
Collapse
Affiliation(s)
- Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Elisabeth Klint
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Peter Milos
- Department of Neurosurgery and Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Johan Richter
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
- Department of Neurosurgery and Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
2
|
Klint E, Richter J, Wårdell K. Combined Use of Frameless Neuronavigation and In Situ Optical Guidance in Brain Tumor Needle Biopsies. Brain Sci 2023; 13:brainsci13050809. [PMID: 37239281 DOI: 10.3390/brainsci13050809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 05/10/2023] [Accepted: 05/13/2023] [Indexed: 05/28/2023] Open
Abstract
Brain tumor needle biopsies are performed to retrieve tissue samples for neuropathological analysis. Although preoperative images guide the procedure, there are risks of hemorrhage and sampling of non-tumor tissue. This study aimed to develop and evaluate a method for frameless one-insertion needle biopsies with in situ optical guidance and present a processing pipeline for combined postoperative analysis of optical, MRI, and neuropathological data. An optical system for quantified feedback on tissue microcirculation, gray-whiteness, and the presence of a tumor (protoporphyrin IX (PpIX) accumulation) with a one-insertion optical probe was integrated into a needle biopsy kit that was used for frameless neuronavigation. In Python, a pipeline for signal processing, image registration, and coordinate transformation was set up. The Euclidian distances between the pre- and postoperative coordinates were calculated. The proposed workflow was evaluated on static references, a phantom, and three patients with suspected high-grade gliomas. In total, six biopsy samples that overlapped with the region of the highest PpIX peak without increased microcirculation were taken. The samples were confirmed as being tumorous and postoperative imaging was used to define the biopsy locations. A 2.5 ± 1.2 mm difference between the pre- and postoperative coordinates was found. Optical guidance in frameless brain tumor biopsies could offer benefits such as quantified in situ indication of high-grade tumor tissue and indications of increased blood flow along the needle trajectory before the tissue is removed. Additionally, postoperative visualization enables the combined analysis of MRI, optical, and neuropathological data.
Collapse
Affiliation(s)
- Elisabeth Klint
- Department of Biomedical Engineering, Linköping University, 581 85 Linköping, Sweden
| | - Johan Richter
- Department of Biomedical Engineering, Linköping University, 581 85 Linköping, Sweden
- Department of Neurosurgery, Linköping University Hospital, 581 85 Linköping, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, 581 85 Linköping, Sweden
| |
Collapse
|
3
|
Nordin T, Blomstedt P, Hemm S, Wårdell K. How Sample Size Impacts Probabilistic Stimulation Maps in Deep Brain Stimulation. Brain Sci 2023; 13:brainsci13050756. [PMID: 37239228 DOI: 10.3390/brainsci13050756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 04/25/2023] [Accepted: 04/28/2023] [Indexed: 05/28/2023] Open
Abstract
Probabilistic stimulation maps of deep brain stimulation (DBS) effect based on voxel-wise statistics (p-maps) have increased in literature over the last decade. These p-maps require correction for Type-1 errors due to multiple testing based on the same data. Some analyses do not reach overall significance, and this study aims to evaluate the impact of sample size on p-map computation. A dataset of 61 essential tremor patients treated with DBS was used for the investigation. Each patient contributed with four stimulation settings, one for each contact. From the dataset, 5 to 61 patients were randomly sampled with replacement for computation of p-maps and extraction of high- and low-improvement volumes. For each sample size, the process was iterated 20 times with new samples generating in total 1140 maps. The overall p-value corrected for multiple comparisons, significance volumes, and dice coefficients (DC) of the volumes within each sample size were evaluated. With less than 30 patients (120 simulations) in the sample, the variation in overall significance was larger and the median significance volumes increased with sample size. Above 120 simulations, the trends stabilize but present some variations in cluster location, with a highest median DC of 0.73 for n = 57. The variation in location was mainly related to the region between the high- and low-improvement clusters. In conclusion, p-maps created with small sample sizes should be evaluated with caution, and above 120 simulations in single-center studies are probably required for stable results.
Collapse
Affiliation(s)
- Teresa Nordin
- Department of Biomedical Engineering, Linköping University, 58185 Linköping, Sweden
| | - Patric Blomstedt
- Department of Clinical Science, Neuroscience, Umeå University, 90185 Umeå, Sweden
| | - Simone Hemm
- Department of Biomedical Engineering, Linköping University, 58185 Linköping, Sweden
- Institute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland, 4132 Muttenz, Switzerland
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, 58185 Linköping, Sweden
| |
Collapse
|
4
|
Milos P, Haj-Hosseini N, Hillman J, Wårdell K. 5-ALA fluorescence in randomly selected pediatric brain tumors assessed by spectroscopy and surgical microscope. Acta Neurochir (Wien) 2023; 165:71-81. [PMID: 36242636 PMCID: PMC9840574 DOI: 10.1007/s00701-022-05360-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 08/25/2022] [Indexed: 01/20/2023]
Abstract
PURPOSE Fluorescence-guided surgery applying 5-aminolevulinic acid (5-ALA) in high-grade gliomas is an established method in adults. In children, results have so far been ambiguous. The aim of this study was to investigate 5-ALA-induced fluorescence in pediatric brain tumors by using the surgical microscope and a spectroscopic hand-held probe. METHODS Fourteen randomly selected children (age 4-17) with newly MRI-verified brain tumors were included. No selection was based on the suspected diagnosis prior to surgery. All patients received 5-ALA (20 mg /kg) either orally or via a gastric tube prior to surgery. Intratumoral fluorescence was detected with the microscope and the probe. Moreover, fluorescence in the skin of the forearm was measured. Histopathology samples revealed seven low-grade gliomas, four medulloblastomas, one diffuse intrinsic pontine glioma, one glioblastoma and one atypical meningioma. Blood samples were analyzed, and potential clinical side effects were monitored. RESULTS Microscopically, vague fluorescence was visible in two patients. Intratumoral fluorescence could be detected in five patients with the probe, including the two patients with vague microscopic fluorescence. Three of the oldest children had PpIX fluorescence in the skin. Nine children did not show any fluorescence in the tumor or in the skin. No clinical side effects or laboratory adverse events were observed. CONCLUSION Fluorescence could not be used to guide surgery in this study, neither with the surgical microscope nor with the hand-held probe. In nine children, no fluorescence was discerned and children with noticeable fluorescence were all older than nine years. 5-ALA was considered safe to apply in children.
Collapse
Affiliation(s)
- Peter Milos
- Department of Neurosurgery and Department of Biomedical and Clinical Sciences, Linköping University, Linköping University Hospital, 581 85, Linköping, Sweden.
| | - Neda Haj-Hosseini
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Jan Hillman
- Department of Neurosurgery and Department of Biomedical and Clinical Sciences, Linköping University, Linköping University Hospital, 581 85, Linköping, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| |
Collapse
|
5
|
Wahl J, Klint E, Hallbeck M, Hillman J, Wårdell K, Ramser K. Impact of preprocessing methods on the Raman spectra of brain tissue. Biomed Opt Express 2022; 13:6763-6777. [PMID: 36589553 PMCID: PMC9774863 DOI: 10.1364/boe.476507] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 11/04/2022] [Accepted: 11/10/2022] [Indexed: 06/01/2023]
Abstract
Delineating cancer tissue while leaving functional tissue intact is crucial in brain tumor resection. Despite several available aids, surgeons are limited by preoperative or subjective tools. Raman spectroscopy is a label-free optical technique with promising indications for tumor tissue identification. To allow direct comparisons between measurements preprocessing of the Raman signal is required. There are many recognized methods for preprocessing Raman spectra; however, there is no universal standard. In this paper, six different preprocessing methods were tested on Raman spectra (n > 900) from fresh brain tissue samples (n = 34). The sample cohort included both primary brain tumors, such as adult-type diffuse gliomas and meningiomas, as well as metastases of breast cancer. Each tissue sample was classified according to the CNS WHO 2021 guidelines. The six methods include both direct and iterative polynomial fitting, mathematical morphology, signal derivative, commercial software, and a neural network. Data exploration was performed using principal component analysis, t-distributed stochastic neighbor embedding, and k-means clustering. For each of the six methods, the parameter combination that explained the most variance in the data, i.e., resulting in the highest Gap-statistic, was chosen and compared to the other five methods. Depending on the preprocessing method, the resulting clusters varied in number, size, and associated spectral features. The detected features were associated with hemoglobin, neuroglobin, carotenoid, water, and protoporphyrin, as well as proteins and lipids. However, the spectral features seen in the Raman spectra could not be unambiguously assigned to tissue labels, regardless of preprocessing method. We have illustrated that depending on the chosen preprocessing method, the spectral appearance of Raman features from brain tumor tissue can change. Therefore, we argue both for caution in comparing spectral features from different Raman studies, as well as the importance of transparency of methodology and implementation of the preprocessing. As discussed in this study, Raman spectroscopy for in vivo guidance in neurosurgery requires fast and adaptive preprocessing. On this basis, a pre-trained neural network appears to be a promising approach for the operating room.
Collapse
Affiliation(s)
- Joel Wahl
- Department of Engineering Sciences and Mathematics, Luleå University of Technology, 971 87, Luleå, Sweden
| | - Elisabeth Klint
- Department of Biomedical Engineering, Linköping University, 581 85 Linköping, Sweden
| | - Martin Hallbeck
- Department of Clinical Pathology and Biomedical and Clinical Sciences, Linköping University, 581 85 Linköping, Sweden
| | - Jan Hillman
- Department of Neurosurgery and Biomedical and Clinical Sciences, Linköping University, 581 85 Linköping, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, 581 85 Linköping, Sweden
| | - Kerstin Ramser
- Department of Engineering Sciences and Mathematics, Luleå University of Technology, 971 87, Luleå, Sweden
| |
Collapse
|
6
|
Mauritzon S, Ginstman F, Hillman J, Wårdell K. Analysis of laser Doppler flowmetry long-term recordings for investigation of cerebral microcirculation during neurointensive care. Front Neurosci 2022; 16:1030805. [PMID: 36408392 PMCID: PMC9671599 DOI: 10.3389/fnins.2022.1030805] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Accepted: 10/18/2022] [Indexed: 11/19/2023] Open
Abstract
Cerebral blood flow is monitored in the neurointensive care unit (NICU) to avoid further brain damage caused by secondary insults following subarachnoid hemorrhage and brain trauma. Current techniques are mainly snap-shot based and focus on larger vessels. However, continuous monitoring of the smaller vessels may help detect the onset of secondary insults at an earlier stage. In this study, long-term measurements of brain microcirculation with laser Doppler flowmetry (LDF) were performed and evaluated. The aim was to identify and describe physiological signal variations and separate these from movement artifacts. Fiberoptic probes for subcortical LDF recordings of perfusion and total light intensity (TLI) were implanted in three patients with subarachnoid hemorrhage. Data were successfully collected and visualized in real-time over 4 days, resulting in 34, 12, and 8.5 h per patient. Visual observation, wavelet transforms, moving medians, and peak envelopes were used to identify and describe movement artifacts and physiological changes. Artifacts occurred in <5% of the total recording time and could be identified through signal processing. Identified physiological signal patterns included a slowly increasing perfusion trend over hours, vasomotion mainly at 2 cycles/min both in the perfusion and the TLI, and rapid, synchronized changes in the TLI and the perfusion on 38 occasions. Continuous LDF recordings indicating changes in the microvascular blood flow can increase the understanding of the microcirculation in the injured brain. In the long run, this may become a complement for the detection of secondary insults at an earlier stage than possible with today's techniques.
Collapse
Affiliation(s)
- Stina Mauritzon
- Neuroengineering Lab, Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Fredrik Ginstman
- Department of Neurosurgery and Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Jan Hillman
- Department of Neurosurgery and Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Karin Wårdell
- Neuroengineering Lab, Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| |
Collapse
|
7
|
Richter J, Klint E, Wårdell K. P07.12.B Brain Biopsy with Optical Guidance. Neuro Oncol 2022. [DOI: 10.1093/neuonc/noac174.144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Accurate stereotactic biopsies of brain tumors are imperative for diagnosis and decisions on therapy. Repetitive needle insertions owing to inconclusive tissue samples enhance increased risks of brain lesioning, hemorrhage and prolonged procedure. Previously we reported on frame-based stereotactic biopsies with a combined 5-ALA fluorescence and laser Doppler flowmetry detection system[1]. The system has now been adapted to frameless navigation with a modified biopsy needle and a new registration system[2].
Material and Methods
Planning was effected with the Medtronic Stealth System. The optical probe was inserted inside the outer cannula of the biopsy needle, which had an opening at the tip, enabling optical measurements ahead of the needle in real-time while manually forwarding it along the trajectory to the target. Fluorescence spectra, microvascular blood flow, and tissue grayness were recorded during insertion. The biopsies were taken where the fluorescence indicated tumor tissue; the optical probe was replaced by the inner cannula. The diagnoses were compared with the fluorescence signals.
Results
In the 9 examined patients the fluorescence measurements and pathological diagnosis of high-grade gliomas or lymphomas matched. Only one needle insertion was necessary. The optical measurements along the trajectory took 5-10 min to the target, the pathological diagnosis was reported after 30-70 min. The probe provided direct feedback of increased blood flow along the trajectory and of malignant tissue in the vicinity of the target.
Conclusion
The optical probe can detect tumor before any tissue is retrieved. If fluorescence is registered, pathological tissue is safely identified. The method can increase the precision and safety of the biopsy and shorten the procedure. The new multimodal probe and the improved registration unit will be tested with other stereotactic and navigation systems and at other neurosurgical centers.
Also, the parallel project on fluorescence guided resection of high-grade gliomas is continued[3].
References
[1] Johan Richter, Neda Haj-Hosseini, Peter Milos, Martin Hallbeck, Karin Wårdell, (2021), Optical Brain Biopsy with a Fluorescence and Vessel Tracing Probe, Operative Neurosurgery, 217-224, 21(4) [2] Elisabeth Klint, Stina Mauritzon, Bengt Ragnemalm, Johan Richter, Karin Wårdell, (2021), FluoRa - a System for Combined Fluorescence and Microcirculation Measurements in Brain Tumor Surgery, Annual International Conference of the IEEE , 1512-1515 [3] Johan Richter, Neda Haj-Hosseini, Martin Hallbeck, Karin Wårdell, (2017), Combination of hand-held probe and microscopy for fluorescence guided surgery in the brain tumor marginal zone, Photodiagnosis and Photodynamic Therapy, 184-192, 18
Collapse
Affiliation(s)
- J Richter
- Neurosurgical Department, Universitetssjukhuset, Linköping University , Linköping , Sweden
| | - E Klint
- Department of Biomedical Engineering; Linköping University , Linköping , Sweden
| | - K Wårdell
- Department of Biomedical Engineering; Linköping University , Linköping , Sweden
| |
Collapse
|
8
|
Nordin T, Vogel D, Österlund E, Johansson J, Blomstedt P, Fytagoridis A, Hemm S, Wårdell K. Probabilistic maps for deep brain stimulation - Impact of methodological differences. Brain Stimul 2022; 15:1139-1152. [PMID: 35987327 DOI: 10.1016/j.brs.2022.08.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 08/11/2022] [Accepted: 08/11/2022] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Group analysis of patients with deep brain stimulation (DBS) has the potential to help understand and optimize the treatment of patients with movement disorders. Probabilistic stimulation maps (PSM) are commonly used to analyze the correlation between tissue stimulation and symptomatic effect but are applied with different methodological variations. OBJECTIVE To compute a group-specific MRI template and PSMs for investigating the impact of PSM model parameters. METHODS Improvement and occurrence of dizziness in 68 essential tremor patients implanted in caudal zona incerta were analyzed. The input data includes the best parameters for each electrode contact (screening), and the clinically used settings. Patient-specific electric field simulations (n = 488) were computed for all DBS settings. The electric fields were transformed to a group-specific MRI template for analysis and visualization. The different comparisons were based on PSMs representing occurrence (N-map), mean improvement (M-map), weighted mean improvement (wM-map), and voxel-wise t-statistics (p-map). These maps were used to investigate the impact from input data (clinical/screening settings), clustering methods, sampling resolution, and weighting function. RESULTS Screening or clinical settings showed the largest impacts on the PSMs. The average differences of wM-maps were 12.4 and 18.2% points for the left and right sides respectively. Extracting clusters based on wM-map or p-map showed notable variation in volumes, while positioning was similar. The impact on the PSMs was small from weighting functions, except for a clear shift in the positioning of the wM-map clusters. CONCLUSION The distribution of the input data and the clustering method are most important to consider when creating PSMs for studying the relationship between anatomy and DBS outcome.
Collapse
Affiliation(s)
- Teresa Nordin
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden.
| | - Dorian Vogel
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden; Institute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland
| | - Erik Österlund
- Department of Clinical Neuroscience, Neurosurgery, Karolinska Institute, Stockholm, Sweden
| | - Johannes Johansson
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Patric Blomstedt
- Department of Clinical Science, Neuroscience, Umeå University, Umeå, Sweden
| | - Anders Fytagoridis
- Department of Clinical Neuroscience, Neurosurgery, Karolinska Institute, Stockholm, Sweden
| | - Simone Hemm
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden; Institute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| |
Collapse
|
9
|
Wårdell K, Nordin T, Vogel D, Zsigmond P, Westin CF, Hariz M, Hemm S. Deep Brain Stimulation: Emerging Tools for Simulation, Data Analysis, and Visualization. Front Neurosci 2022; 16:834026. [PMID: 35478842 PMCID: PMC9036439 DOI: 10.3389/fnins.2022.834026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Accepted: 03/01/2022] [Indexed: 01/10/2023] Open
Abstract
Deep brain stimulation (DBS) is a well-established neurosurgical procedure for movement disorders that is also being explored for treatment-resistant psychiatric conditions. This review highlights important consideration for DBS simulation and data analysis. The literature on DBS has expanded considerably in recent years, and this article aims to identify important trends in the field. During DBS planning, surgery, and follow up sessions, several large data sets are created for each patient, and it becomes clear that any group analysis of such data is a big data analysis problem and has to be handled with care. The aim of this review is to provide an update and overview from a neuroengineering perspective of the current DBS techniques, technical aids, and emerging tools with the focus on patient-specific electric field (EF) simulations, group analysis, and visualization in the DBS domain. Examples are given from the state-of-the-art literature including our own research. This work reviews different analysis methods for EF simulations, tractography, deep brain anatomical templates, and group analysis. Our analysis highlights that group analysis in DBS is a complex multi-level problem and selected parameters will highly influence the result. DBS analysis can only provide clinically relevant information if the EF simulations, tractography results, and derived brain atlases are based on as much patient-specific data as possible. A trend in DBS research is creation of more advanced and intuitive visualization of the complex analysis results suitable for the clinical environment.
Collapse
Affiliation(s)
- Karin Wårdell
- Neuroengineering Lab, Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Teresa Nordin
- Neuroengineering Lab, Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Dorian Vogel
- Neuroengineering Lab, Department of Biomedical Engineering, Linköping University, Linköping, Sweden
- Institute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland
| | - Peter Zsigmond
- Department of Neurosurgery and Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Carl-Fredrik Westin
- Neuroengineering Lab, Department of Biomedical Engineering, Linköping University, Linköping, Sweden
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, United States
| | - Marwan Hariz
- Unit of Functional Neurosurgery, UCL Queen Square Institute of Neurology, London, United Kingdom
- Department of Clinical Sciences, Neuroscience, Ume University, Umeå, Sweden
| | - Simone Hemm
- Neuroengineering Lab, Department of Biomedical Engineering, Linköping University, Linköping, Sweden
- Institute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland
| |
Collapse
|
10
|
Naesström M, Johansson J, Hariz M, Bodlund O, Wårdell K, Blomstedt P. Distribution of electric field in patients with obsessive compulsive disorder treated with deep brain stimulation of the bed nucleus of stria terminalis. Acta Neurochir (Wien) 2022; 164:193-202. [PMID: 34652518 PMCID: PMC8761125 DOI: 10.1007/s00701-021-04991-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Accepted: 08/26/2021] [Indexed: 12/20/2022]
Abstract
Background Deep brain stimulation (DBS) is being investigated as a treatment for therapy-refractory obsessive compulsive disorder (OCD). Many different brain targets are being trialled. Several of these targets such as the ventral striatum (including the nucleus accumbens (NAc)), the ventral capsule, the inferior thalamic peduncle, and the bed nucleus of stria terminalis (BNST)) belong to the same network, are anatomically very close to one another, or even overlap. Data is still missing on how various stimulation parameters in a given target will affect surrounding anatomical areas and impact the clinical outcome of DBS. Methods In a pilot study of eleven participants with DBS of the BNST, we investigate through patient-specific simulation of electric field, which anatomical areas are affected by the electric field, and if this can be related to the clinical results. Our study combined individual patient’s stimulation parameters at 12- and 24-month follow-up with image data from the preoperative MRI and postoperative CT. These data were used to calculate the distribution of electric field and create individual anatomical models of the field of stimulation. Results The individual electric stimulation fields by stimulation in the BNST were similar at both the 12- and 24-month follow-up, involving mainly anterior limb of the internal capsule (ALIC), genu of the internal capsule (IC), BNST, fornix, anteromedial globus pallidus externa (GPe), and the anterior commissure. A statistical significant correlation (p < 0.05) between clinical effect measured by the Yale-Brown Obsessive Compulsive Scale and stimulation was found at the 12-month follow-up in the ventral ALIC and anteromedial GPe. Conclusions Many of the targets under investigation for OCD are in anatomical proximity. As seen in our study, off-target effects are overlapping. Therefore, DBS in the region of ALIC, NAc, and BNST may perhaps be considered to be stimulation of the same target.
Collapse
Affiliation(s)
- Matilda Naesström
- Division of Psychiatry, Department of Clinical Sciences, Umeå University, 90187, Umeå, Sweden.
| | - Johannes Johansson
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Marwan Hariz
- Unit of Deep Brain Stimulation, Department of Clinical Sciences, Umeå University, Umeå, Sweden
- Unit of Functional Neurosurgery, UCL Institute of Neurology, Queen Square, London, UK
| | - Owe Bodlund
- Division of Psychiatry, Department of Clinical Sciences, Umeå University, 90187, Umeå, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Patric Blomstedt
- Unit of Deep Brain Stimulation, Department of Clinical Sciences, Umeå University, Umeå, Sweden
| |
Collapse
|
11
|
Stenmark Persson R, Nordin T, Hariz GM, Wårdell K, Forsgren L, Hariz M, Blomstedt P. Deep Brain Stimulation of Caudal Zona Incerta for Parkinson's Disease: One-Year Follow-Up and Electric Field Simulations. Neuromodulation 2021; 25:935-944. [PMID: 34313376 DOI: 10.1111/ner.13500] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Revised: 06/04/2021] [Accepted: 06/29/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To evaluate the effects of bilateral caudal zona incerta (cZi) deep brain stimulation (DBS) for Parkinson's disease (PD) one year after surgery and to create anatomical improvement maps based on patient-specific simulation of the electric field. MATERIALS AND METHODS We report the one-year results of bilateral cZi-DBS in 15 patients with PD. Patients were evaluated on/off medication and stimulation using the Unified Parkinson's Disease Rating Scale (UPDRS). Main outcomes were changes in motor symptoms (UPDRS-III) and quality of life according to Parkinson's Disease Questionnaire-39 (PDQ-39). Secondary outcomes included efficacy profile according to sub-items of UPDRS-III, and simulation of the electric field distribution around the DBS lead using the finite element method. Simulations from all patients were transformed to one common magnetic resonance imaging template space for creation of improvement maps and anatomical evaluation. RESULTS Median UPDRS-III score off medication improved from 40 at baseline to 21 on stimulation at one-year follow-up (48%, p < 0.0005). PDQ-39 summary index did not change but the subdomains activities of daily living (ADL) and stigma improved (25%, p < 0.03 and 75%, p < 0.01), whereas communication worsened (p < 0.03). For UPDRS-III sub-items, stimulation alone reduced median tremor score by 9 points, akinesia by 3, and rigidity by 2 points at one-year follow-up in comparison to baseline (90%, 25%, and 29% respectively, p < 0.01). Visual analysis of the anatomical improvement maps based on simulated electrical fields showed no evident relation with the degree of symptom improvement and neither did statistical analysis show any significant correlation. CONCLUSIONS Bilateral cZi-DBS alleviates motor symptoms, especially tremor, and improves ADL and stigma in PD patients one year after surgery. Improvement maps may be a useful tool for visualizing the spread of the electric field. However, there was no clear-cut relation between anatomical location of the electric field and the degree of symptom relief.
Collapse
Affiliation(s)
| | - Teresa Nordin
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Gun-Marie Hariz
- Department of Clinical Science, Neuroscience, Umeå University, Umeå, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Lars Forsgren
- Department of Clinical Science, Neuroscience, Umeå University, Umeå, Sweden
| | - Marwan Hariz
- Department of Clinical Science, Neuroscience, Umeå University, Umeå, Sweden.,Unit of Functional Neurosurgery, UCL Queen Square Institute of Neurology, London, UK
| | - Patric Blomstedt
- Department of Clinical Science, Neuroscience, Umeå University, Umeå, Sweden
| |
Collapse
|
12
|
Richter J, Haj-Hosseini N, Milos P, Hallbeck M, Wårdell K. Optical Brain Biopsy with a Fluorescence and Vessel Tracing Probe. Oper Neurosurg (Hagerstown) 2021; 21:217-224. [PMID: 34192763 PMCID: PMC8440062 DOI: 10.1093/ons/opab216] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 04/29/2021] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Accurate stereotactic biopsies of brain tumors are imperative for diagnosis and tailoring of the therapy. Repetitive needle insertions enhance risks of brain lesioning, hemorrhage, and complications due to prolonged procedure. OBJECTIVE To investigate clinical benefits of a combined 5-aminolaevulinic acid (5-ALA) fluorescence and laser Doppler flowmetry system for the detection of malignant brain tumor and blood vessels in stereotactic biopsies. METHODS Planning of targets and trajectories was followed by optical measurements in 20 patients, using the Leksell Stereotactic System and a manual insertion device. Fluorescence spectra, microvascular blood flow, and tissue grayness were recorded each millimeter along the paths. Biopsies were taken at preplanned positions. The diagnoses were compared with the fluorescence signals. The recordings were plotted against measurement positions and compared. Sites indicating a risk of hemorrhage were counted as well as the time for the procedures. RESULTS Signals were recorded along 28 trajectories, and 78 biopsies were collected. The final diagnosis showed 17 glioblastomas, 2 lymphomas, and 1 astrocytoma grade III. Fluorescence was seen along 23 of the paths with 4 having the peak of 5-ALA fluorescence 3 mm or more from the precalculated target. There was increased microcirculation in 40 of 905 measured positions. The measurement time for each trajectory was 5 to 10 min. CONCLUSION The probe provided direct feedback of increased blood flow along the trajectory and of malignant tissue in the vicinity of the target. The method can increase the precision and the safety of the biopsy procedure and reduce time.
Collapse
Affiliation(s)
- Johan Richter
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden.,Department of Neurosurgery, Linköping University, Linköping, Sweden.,Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Neda Haj-Hosseini
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Peter Milos
- Department of Neurosurgery, Linköping University, Linköping, Sweden.,Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - Martin Hallbeck
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.,Department of Clinical Pathology, Linköping University, Linköping, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| |
Collapse
|
13
|
Alonso F, Zsigmond P, Wårdell K. Influence of Virchow-Robin spaces on the electric field distribution in subthalamic nucleus deep brain stimulation. Clin Neurol Neurosurg 2021; 204:106596. [PMID: 33813373 DOI: 10.1016/j.clineuro.2021.106596] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 10/12/2020] [Accepted: 03/02/2021] [Indexed: 10/22/2022]
Abstract
Patient MRI from DBS implantations in the subthalamic nucleus (STN) were reviewed and it was found that around 10% had Virchow-Robin spaces (VRS). Patient-specific models were developed to evaluate changes in the electric field (EF) around DBS leads. The patients (n = 7) were implanted bilaterally either with the standard voltage-controlled lead 3389 or with the directional current-controlled lead 6180. The EF distribution was evaluated by comparing simulations using patient-specific models with homogeneous models without VRS. The EF, depicted with an isocontour of 0.2 V/mm, showed a deformation in the presence of the VRS around the DBS lead. For patient-specific models, the radial extension of the EF isocontours was enlarged regardless of the operating mode or the DBS lead used. The location of the VRS in relation to the active contact and the stimulation amplitude, determined the changes in the shape and extension of the EF. It is concluded that it is important to take the patients' brain anatomy into account as the high conductivity in VRS will alter the electric field if close to the DBS lead. This can be a cause of unexpected side effects.
Collapse
Affiliation(s)
- Fabiola Alonso
- Department of Biomedical Engineering, Linköping University, Sweden
| | - Peter Zsigmond
- Department of Neurosurgery and Department of Biomedical and Clinical Sciences, Linköping University, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Sweden; Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden
| |
Collapse
|
14
|
Göransson N, Johansson JD, Wårdell K, Zsigmond P. Postoperative Lead Movement after Deep Brain Stimulation Surgery and the Change of Stimulation Volume. Stereotact Funct Neurosurg 2020; 99:221-229. [PMID: 33326986 DOI: 10.1159/000511406] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Accepted: 08/25/2020] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Lead movement after deep brain stimulation may occur and influence the affected volume of stimulation. The aim of the study was to investigate differences in lead position between the day after surgery and approximately 1 month postoperatively and also simulate the electric field (EF) around the active contacts in order to investigate the impact of displacement on affected volume. METHODS Twenty-three patients with movement disorders underwent deep brain stimulation surgery (37 leads). Computed tomography at the 2 time points were co-fused respectively with the stereotactic images in Surgiplan. The coordinates (x, y, and z) of the lead tips were compared between the 2 dates. Eleven of these patients were selected for the EF simulation in Comsol Multiphysics. Postoperative changes of EF spread in the tissue due to conductivity changes in perielectrode space and due to displacement were evaluated by calculating the coverage coefficient and the Sørensen-Dice coefficient. RESULTS There was a significant displacement (mean ± SD) on the left lead: x (0.44 ± 0.72, p < 0.01), y (0.64 ± 0.54, p < 0.001), and z (0.62 ± 0.71, p < 0.001). On the right lead, corresponding values were: x (-0.11 ± 0.61, ns), y (0.71 ± 0.54, p < 0.001), and z (0.49 ± 0.81, p < 0.05). The anchoring technique was a statistically significant variable associated with displacement. No correlation was found between bilateral (n = 14) versus unilateral deep brain stimulation, gender (n = 17 male), age <60 years (n = 8), and calculated air volume. The simulated stimulation volume was reduced after 1 month because of the perielectrode space. When considering perielectrode space and displacement, the volumes calculated the day after surgery and approximately 1 month later were partly overlapped. CONCLUSION The left lead tip displayed a tendency to move lateral, anterior, and inferior and the right a tendency to move anterior and inferior. The anchoring technique was associated to displacement. New brain territory was affected due to the displacement despite considering the reduced stimulated volume after 1 month. Postoperative changes in perielectrode space and small lead movements are reasons for delaying programming to 4 weeks following surgery.
Collapse
Affiliation(s)
- Nathanael Göransson
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden, .,Department of Neurosurgery and Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden,
| | - Johannes D Johansson
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden
| | - Peter Zsigmond
- Department of Neurosurgery and Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
15
|
Vogel D, Shah A, Coste J, Lemaire JJ, Wårdell K, Hemm S. Anatomical brain structures normalization for deep brain stimulation in movement disorders. Neuroimage Clin 2020; 27:102271. [PMID: 32446242 PMCID: PMC7240191 DOI: 10.1016/j.nicl.2020.102271] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 04/09/2020] [Accepted: 04/20/2020] [Indexed: 11/25/2022]
Abstract
Non-linear iterative structural normalization method focused on the deep brain. Multi-modality image data from deep brain stimulation patients. Comparison of ANTS, FNIRT and DRAMMS for the non-linear registrations using different settings for each. Evaluation of the registration tools based on the analysis of 58 structures of the deep brain segmented manually by a single expert. ANTS was identified as the best performing non-linear registration tool.
Deep brain stimulation (DBS) therapy requires extensive patient-specific planning prior to implantation to achieve optimal clinical outcomes. Collective analysis of patient’s brain images is promising in order to provide more systematic planning assistance. In this paper the design of a normalization pipeline using a group specific multi-modality iterative template creation process is presented. The focus was to compare the performance of a selection of freely available registration tools and select the best combination. The workflow was applied on 19 DBS patients with T1 and WAIR modality images available. Non-linear registrations were computed with ANTS, FNIRT and DRAMMS, using several settings from the literature. Registration accuracy was measured using single-expert labels of thalamic and subthalamic structures and their agreement across the group. The best performance was provided by ANTS using the High Variance settings published elsewhere. Neither FNIRT nor DRAMMS reached the level of performance of ANTS. The resulting normalized definition of anatomical structures were used to propose an atlas of the diencephalon region defining 58 structures using data from 19 patients.
Collapse
Affiliation(s)
- Dorian Vogel
- Institute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland, Hofackerstrasse 30, 4132 Muttenz, Switzerland; Department of Biomedical Engineering, Linköping University, SE-581 85 Linköping, Sweden.
| | - Ashesh Shah
- Institute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland, Hofackerstrasse 30, 4132 Muttenz, Switzerland.
| | - Jérôme Coste
- Université Clermont Auvergne, CNRS, SIGMA Clermont, Institut Pascal, F-63000 Clermont-Ferrand, France; Service de Neurochirurgie, Hôpital Gabriel-Montpied, Centre Hospitalier Universitaire de Clermont-Ferrand, 58 rue Montalembert, F-63003 Clermont-Ferrand Cedex 1, France.
| | - Jean-Jacques Lemaire
- Université Clermont Auvergne, CNRS, SIGMA Clermont, Institut Pascal, F-63000 Clermont-Ferrand, France; Service de Neurochirurgie, Hôpital Gabriel-Montpied, Centre Hospitalier Universitaire de Clermont-Ferrand, 58 rue Montalembert, F-63003 Clermont-Ferrand Cedex 1, France.
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, SE-581 85 Linköping, Sweden.
| | - Simone Hemm
- Institute for Medical Engineering and Medical Informatics, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland, Hofackerstrasse 30, 4132 Muttenz, Switzerland; Department of Biomedical Engineering, Linköping University, SE-581 85 Linköping, Sweden.
| |
Collapse
|
16
|
Zsigmond P, Wårdell K. Optical Measurements during Asleep Deep Brain Stimulation Surgery along Vim-Zi Trajectories. Stereotact Funct Neurosurg 2020; 98:55-61. [PMID: 32079023 DOI: 10.1159/000505708] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Accepted: 12/31/2019] [Indexed: 11/19/2022]
Abstract
BACKGROUND Optics can be used for guidance in deep brain stimulation (DBS) surgery. The aim was to use laser Doppler flowmetry (LDF) to investigate the intraoperative optical trajectory along the ventral intermediate nucleus (VIM) and zona incerta (Zi) regions in patients with essential tremor during asleep DBS surgery, and whether the Zi region could be identified. METHODS A forward-looking LDF guide was used for creation of the trajectory for the DBS lead, and the microcirculation and tissue greyness, i.e., total light intensity (TLI) was measured along 13 trajectories. TLI trajectories and the number of high-perfusion spots were investigated at 0.5-mm resolution in the last 25 mm from the targets. RESULTS All implantations were done without complications and with significant improvement of tremor (p < 0.01). Out of 798 measurements, 12 tissue spots showed high blood flow. The blood flow was significantly higher in VIM than in Zi (p < 0.001). The normalized mean TLI curve showed a significant (p < 0.001) lower TLI in the VIM region than in the Zi region. CONCLUSION Zi DBS performed asleep appears to be safe and effective. LDF monitoring provides direct in vivomeasurement of the microvascular blood flow in front of the probe, which can help reduce the risk of hemorrhage. LDF can differentiate between the grey substance in the thalamus and the transmission border entering the posterior subthalamic area where the tissue consists of more white matter tracts.
Collapse
Affiliation(s)
- Peter Zsigmond
- Departments of Neurosurgery and Clinical and Experimental Medicine, Linköping University, Linköping, Sweden,
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| |
Collapse
|
17
|
Shah A, Vogel D, Alonso F, Lemaire JJ, Pison D, Coste J, Wårdell K, Schkommodau E, Hemm S. Stimulation maps: visualization of results of quantitative intraoperative testing for deep brain stimulation surgery. Med Biol Eng Comput 2020; 58:771-784. [PMID: 32002754 PMCID: PMC7156362 DOI: 10.1007/s11517-020-02130-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Accepted: 01/06/2020] [Indexed: 11/27/2022]
Abstract
Deep brain stimulation (DBS) is an established therapy for movement disorders such as essential tremor (ET). Positioning of the DBS lead in the patient's brain is crucial for effective treatment. Extensive evaluations of improvement and adverse effects of stimulation at different positions for various current amplitudes are performed intraoperatively. However, to choose the optimal position of the lead, the information has to be "mentally" visualized and analyzed. This paper introduces a new technique called "stimulation maps," which summarizes and visualizes the high amount of relevant data with the aim to assist in identifying the optimal DBS lead position. It combines three methods: outlines of the relevant anatomical structures, quantitative symptom evaluation, and patient-specific electric field simulations. Through this combination, each voxel in the stimulation region is assigned one value of symptom improvement, resulting in the division of stimulation region into areas with different improvement levels. This technique was applied retrospectively to five ET patients in the University Hospital in Clermont-Ferrand, France. Apart from identifying the optimal implant position, the resultant nine maps show that the highest improvement region is frequently in the posterior subthalamic area. The results demonstrate the utility of the stimulation maps in identifying the optimal implant position. Graphical abstract.
Collapse
Affiliation(s)
- Ashesh Shah
- Institute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland
| | - Dorian Vogel
- Institute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Fabiola Alonso
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Jean-Jacques Lemaire
- CNRS, SIGMA Clermont, Institut Pascal, Université Clermont Auvergne, Clermont-Ferrand, France
- Service de Neurochirurgie, Hôpital Gabriel-Montpied, Centre Hospitalier Universitaire de Clermont-Ferrand, Clermont-Ferrand, France
| | - Daniela Pison
- Institute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland
| | - Jérôme Coste
- CNRS, SIGMA Clermont, Institut Pascal, Université Clermont Auvergne, Clermont-Ferrand, France
- Service de Neurochirurgie, Hôpital Gabriel-Montpied, Centre Hospitalier Universitaire de Clermont-Ferrand, Clermont-Ferrand, France
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Erik Schkommodau
- Institute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland
| | - Simone Hemm
- Institute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland.
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden.
| |
Collapse
|
18
|
Nordin T, Zsigmond P, Pujol S, Westin CF, Wårdell K. White matter tracing combined with electric field simulation - A patient-specific approach for deep brain stimulation. Neuroimage Clin 2019; 24:102026. [PMID: 31795055 PMCID: PMC6880013 DOI: 10.1016/j.nicl.2019.102026] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 09/04/2019] [Accepted: 10/02/2019] [Indexed: 11/23/2022]
Abstract
OBJECTIVE Deep brain stimulation (DBS) in zona incerta (Zi) is used for symptom alleviation in essential tremor (ET). Zi is positioned along the dentato-rubro-thalamic tract (DRT). Electric field simulations with the finite element method (FEM) can be used for estimation of a volume where the stimulation affects the tissue by applying a fixed isolevel (VDBS). This work aims to develop a workflow for combined patient-specific electric field simulation and white matter tracing of the DRT, and to investigate the influence on the VDBS from different brain tissue models, lead design and stimulation modes. The novelty of this work lies in the combination of all these components. METHOD Patients with ET were implanted in Zi (lead 3389, n = 3, voltage mode; directional lead 6172, n = 1, current mode). Probabilistic reconstruction from diffusion MRI (dMRI) of the DRT (n = 8) was computed with FSL Toolbox. Brain tissue models were created for each patient (two homogenous, one heterogenous isotropic, one heterogenous anisotropic) and the respective VDBS (n = 48) calculated from the Comsol Multiphysics FEM simulations. The DRT and VDBS were visualized with 3DSlicer and superimposed on the preoperative T2 MRI, and the common volumes calculated. Dice Coefficient (DC) and level of anisotropy were used to evaluate and compare the brain models. RESULT Combined patient-specific tractography and electric field simulation was designed and evaluated, and all patients showed benefit from DBS. All VDBS overlapped the reconstructed DRT. Current stimulation showed prominent difference between the tissue models, where the homogenous grey matter deviated most (67 < DC < 69). Result from heterogenous isotropic and anisotropic models were similar (DC > 0.95), however the anisotropic model consistently generated larger volumes related to a greater extension of the electric field along the DBS lead. Independent of tissue model, the steering effect of the directional lead was evident and consistent. CONCLUSION A workflow for patient-specific electric field simulations in combination with reconstruction of DRT was successfully implemented. Accurate tissue classification is essential for electric field simulations, especially when using the current control stimulation. With an accurate targeting and tractography reconstruction, directional leads have the potential to tailor the electric field into the desired region.
Collapse
Affiliation(s)
- Teresa Nordin
- Department of Biomedical Engineering, Linköping University, Sweden.
| | - Peter Zsigmond
- Department of Neurosurgery and Clinical and Experimental Medicine, Linköping University, Sweden
| | - Sonia Pujol
- Laboratory of Mathematics in Imaging, Brigham and Women's Hospital, Harvard Medical School, USA; Surgical Planning Laboratory, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, USA
| | - Carl-Fredrik Westin
- Laboratory of Mathematics in Imaging, Brigham and Women's Hospital, Harvard Medical School, USA
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Sweden
| |
Collapse
|
19
|
Latorre MA, Wårdell K. A comparison between single and double cable neuron models applicable to deep brain stimulation. Biomed Phys Eng Express 2019. [DOI: 10.1088/2057-1976/aafdd9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
20
|
|
21
|
Haj-Hosseini N, Richter JCO, Milos P, Hallbeck M, Wårdell K. 5-ALA fluorescence and laser Doppler flowmetry for guidance in a stereotactic brain tumor biopsy. Biomed Opt Express 2018; 9:2284-2296. [PMID: 29760987 PMCID: PMC5946788 DOI: 10.1364/boe.9.002284] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Revised: 03/27/2018] [Accepted: 04/09/2018] [Indexed: 05/21/2023]
Abstract
A fiber optic probe was developed for guidance during stereotactic brain biopsy procedures to target tumor tissue and reduce the risk of hemorrhage. The probe was connected to a setup for the measurement of 5-aminolevulinic acid (5-ALA) induced fluorescence and microvascular blood flow. Along three stereotactic trajectories, fluorescence (n = 109) and laser Doppler flowmetry (LDF) (n = 144) measurements were done in millimeter increments. The recorded signals were compared to histopathology and radiology images. The median ratio of protoporphyrin IX (PpIX) fluorescence and autofluorescence (AF) in the tumor was considerably higher than the marginal zone (17.3 vs 0.9). The blood flow showed two high spots (3%) in total. The proposed setup allows simultaneous and real-time detection of tumor tissue and microvascular blood flow for tracking the vessels.
Collapse
Affiliation(s)
| | - Johan C. O. Richter
- Department of Biomedical Engineering, Linköping University, Sweden
- Department of Neurosurgery, Linköping University Hospital, County Council Östergötland, Linköping, Sweden
| | - Peter Milos
- Department of Neurosurgery, Linköping University Hospital, County Council Östergötland, Linköping, Sweden
| | - Martin Hallbeck
- Department of Clinical Pathology and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Sweden
| |
Collapse
|
22
|
Alonso F, Vogel D, Johansson J, Wårdell K, Hemm S. Electric Field Comparison between Microelectrode Recording and Deep Brain Stimulation Systems-A Simulation Study. Brain Sci 2018; 8:brainsci8020028. [PMID: 29415442 PMCID: PMC5836047 DOI: 10.3390/brainsci8020028] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 01/30/2018] [Accepted: 02/01/2018] [Indexed: 12/24/2022] Open
Abstract
The success of deep brain stimulation (DBS) relies primarily on the localization of the implanted electrode. Its final position can be chosen based on the results of intraoperative microelectrode recording (MER) and stimulation tests. The optimal position often differs from the final one selected for chronic stimulation with the DBS electrode. The aim of the study was to investigate, using finite element method (FEM) modeling and simulations, whether lead design, electrical setup, and operating modes induce differences in electric field (EF) distribution and in consequence, the clinical outcome. Finite element models of a MER system and a chronic DBS lead were developed. Simulations of the EF were performed for homogenous and patient-specific brain models to evaluate the influence of grounding (guide tube vs. stimulator case), parallel MER leads, and non-active DBS contacts. Results showed that the EF is deformed depending on the distance between the guide tube and stimulating contact. Several parallel MER leads and the presence of the non-active DBS contacts influence the EF distribution. The DBS EF volume can cover the intraoperatively produced EF, but can also extend to other anatomical areas. In conclusion, EF deformations between stimulation tests and DBS should be taken into consideration as they can alter the clinical outcome.
Collapse
Affiliation(s)
- Fabiola Alonso
- Department of Biomedical Engineering, Linköping University, 58185 Linköping, Sweden.
| | - Dorian Vogel
- Department of Biomedical Engineering, Linköping University, 58185 Linköping, Sweden.
- Institute for Medical and Analytical Technologies, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland FHNW, 4132 Muttenz, Switzerland.
| | - Johannes Johansson
- Department of Biomedical Engineering, Linköping University, 58185 Linköping, Sweden.
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, 58185 Linköping, Sweden.
| | - Simone Hemm
- Department of Biomedical Engineering, Linköping University, 58185 Linköping, Sweden.
- Institute for Medical and Analytical Technologies, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland FHNW, 4132 Muttenz, Switzerland.
| |
Collapse
|
23
|
Zsigmond P, Hemm-Ode S, Wårdell K. Optical Measurements during Deep Brain Stimulation Lead Implantation: Safety Aspects. Stereotact Funct Neurosurg 2018; 95:392-399. [DOI: 10.1159/000484944] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Accepted: 11/01/2017] [Indexed: 11/19/2022]
|
24
|
Rejmstad P, Haj-Hosseini N, Åneman O, Wårdell K. Optical monitoring of cerebral microcirculation in neurointensive care. Med Biol Eng Comput 2017; 56:1201-1210. [PMID: 29218511 PMCID: PMC6013533 DOI: 10.1007/s11517-017-1725-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Accepted: 09/14/2017] [Indexed: 11/29/2022]
Abstract
Continuous optical monitoring of local cerebral microcirculation could benefit neurointensive care patients treated for subarachnoid hemorrhage (SAH). The aim of the study was to evaluate laser Doppler flowmetry (LDF) and diffuse reflectance spectroscopy (DRS) for long-term monitoring of brain microcirculation and oxygen saturation (SO2) in the neurointensive care unit (NICU). A fiber optic probe was designed for intraparenchymal use and connected to LDF and DRS for assessment of the local blood flow (perfusion and tissue reflectance (TLI)) and SO2 in the brain. The optically monitored parameters were compared with conventional NICU monitors and Xe-CT. The LDF signals were low with median and 25 to 75% interquartiles of perfusion = 70 (59 to 83) a.u. and TLI = 2.0 (1.0 to 2.4) a.u. and showed correlation with the NICU monitors in terms of heart rate. Median and interquartiles of SO2 were 17.4 (15.7 to 19.8) %. The lack of correlation between local perfusion and cerebral perfusion pressure indicated intact cerebral autoregulation. The systems were capable of monitoring both local perfusion and SO2 with stable signals in the NICU over 4 days. Further clinical studies are required to evaluate the optical systems’ potential for assessing the onset of secondary brain injury.
Collapse
Affiliation(s)
- Peter Rejmstad
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden.
| | - Neda Haj-Hosseini
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Oscar Åneman
- Department of Neurosurgery, Linköping University Hospital, Linköping, Sweden.,Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| |
Collapse
|
25
|
Black D, Hahn HK, Kikinis R, Wårdell K, Haj-Hosseini N. Auditory display for fluorescence-guided open brain tumor surgery. Int J Comput Assist Radiol Surg 2017; 13:25-35. [PMID: 28929305 DOI: 10.1007/s11548-017-1667-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2017] [Accepted: 09/07/2017] [Indexed: 02/02/2023]
Abstract
PURPOSE Protoporphyrin (PpIX) fluorescence allows discrimination of tumor and normal brain tissue during neurosurgery. A handheld fluorescence (HHF) probe can be used for spectroscopic measurement of 5-ALA-induced PpIX to enable objective detection compared to visual evaluation of fluorescence. However, current technology requires that the surgeon either views the measured values on a screen or employs an assistant to verbally relay the values. An auditory feedback system was developed and evaluated for communicating measured fluorescence intensity values directly to the surgeon. METHODS The auditory display was programmed to map the values measured by the HHF probe to the playback of tones that represented three fluorescence intensity ranges and one error signal. Ten persons with no previous knowledge of the application took part in a laboratory evaluation. After a brief training period, participants performed measurements on a tray of 96 wells of liquid fluorescence phantom and verbally stated the perceived measurement values for each well. The latency and accuracy of the participants' verbal responses were recorded. The long-term memorization of sound function was evaluated in a second set of 10 participants 2-3 and 7-12 days after training. RESULTS The participants identified the played tone accurately for 98% of measurements after training. The median response time to verbally identify the played tones was 2 pulses. No correlation was found between the latency and accuracy of the responses, and no significant correlation with the musical proficiency of the participants was observed on the function responses. Responses for the memory test were 100% accurate. CONCLUSION The employed auditory display was shown to be intuitive, easy to learn and remember, fast to recognize, and accurate in providing users with measurements of fluorescence intensity or error signal. The results of this work establish a basis for implementing and further evaluating auditory displays in clinical scenarios involving fluorescence guidance and other areas for which categorized auditory display could be useful.
Collapse
Affiliation(s)
- David Black
- Medical Image Computing, University of Bremen, Bremen, Germany.
- Jacobs University, Bremen, Germany.
- Fraunhofer MEVIS, Bremen, Germany.
| | - Horst K Hahn
- Jacobs University, Bremen, Germany
- Fraunhofer MEVIS, Bremen, Germany
| | - Ron Kikinis
- Medical Image Computing, University of Bremen, Bremen, Germany
- Fraunhofer MEVIS, Bremen, Germany
- Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| | - Neda Haj-Hosseini
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden
| |
Collapse
|
26
|
Akbarian-Tefaghi L, Akram H, Johansson J, Zrinzo L, Kefalopoulou Z, Limousin P, Joyce E, Hariz M, Wårdell K, Foltynie T. Refining the Deep Brain Stimulation Target within the Limbic Globus Pallidus Internus for Tourette Syndrome. Stereotact Funct Neurosurg 2017; 95:251-258. [PMID: 28787721 DOI: 10.1159/000478273] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2017] [Accepted: 06/08/2017] [Indexed: 11/19/2022]
Abstract
BACKGROUND Deep brain stimulation (DBS) in patients with severe, refractory Tourette syndrome (TS) has demonstrated promising but variable results thus far. The thalamus and anteromedial globus pallidus internus (amGPi) have been the most commonly stimulated sites within the cortico-striato thalamic circuit, but an optimal target is yet to be elucidated. OBJECTIVES This study of 15 patients with long-term amGPi DBS for severe TS investigated whether a specific anatomical site within the amGPi correlated with optimal clinical outcome for the measures of tics, obsessive compulsive behaviour (OCB), and mood. METHODS Validated clinical assessments were used to measure tics, OCB, quality of life, anxiety, and depression before DBS and at the latest follow-up (17-82 months). Electric field simulations were created for each patient using information on electrode location and individual stimulation parameters. A subsequent regression analysis correlated these patient-specific simulations to percentage changes in outcome measures in order to identify any significant voxels related to clinical improvement. RESULTS A region within the ventral limbic GPi, specifically on the medial medullary lamina in the pallidum at the level of the AC-PC, was significantly associated with improved tics but not mood or OCB outcome. CONCLUSIONS This study adds further support to the application of DBS in a tic-related network, though factors such as patient sample size and clinical heterogeneity remain as limitations and replication is required.
Collapse
Affiliation(s)
- Ladan Akbarian-Tefaghi
- Unit of Functional Neurosurgery, Sobell Department of Motor Neuroscience, UCL Institute of Neurology, London, UK
| | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Rejmstad P, Zsigmond P, Wårdell K. Oxygen saturation estimation in brain tissue using diffuse reflectance spectroscopy along stereotactic trajectories. Opt Express 2017; 25:8192-8201. [PMID: 28380934 DOI: 10.1364/oe.25.008192] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Diffuse reflectance spectroscopy (DRS) can be used to estimate oxygen saturation (SO2) of hemoglobin and blood fraction (fB) in brain tissue. The aim of the study was to investigate the SO2 and fB in different positions along deep brain stimulation (DBS) trajectories and in specific target regions using DRS and a novel algorithm. DRS measurements were done at 166 well-defined anatomical positions in relation to stereotactic DBS-implantation along 20 trajectories toward 4 DBS targets (STN, Vim, GPi and Zi). The measurements were dived into groups (gray, white and light gray matter) related to anatomical position, and DBS targets, before comparison and statistical analysis. The median SO2 in gray, white and light gray matter were 52%, 24% and 20%, respectively. Median fB in gray matter (3.9%) was different from values in white (1.0%, p < 0.05) and light gray (0.9%, p < 0.001) matter. No significant difference in median SO2 and fB was found between DBS target regions. The novel algorithm allows for quick and reliable estimation of SO2 and fB in human brain tissue.
Collapse
|
28
|
Rejmstad P, Johansson JD, Haj-Hosseini N, Wårdell K. A method for monitoring of oxygen saturation changes in brain tissue using diffuse reflectance spectroscopy. J Biophotonics 2017; 10:446-455. [PMID: 27094015 DOI: 10.1002/jbio.201500334] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Revised: 02/26/2016] [Accepted: 03/22/2016] [Indexed: 05/09/2023]
Abstract
Continuous measurement of local brain oxygen saturation (SO2 ) can be used to monitor the status of brain trauma patients in the neurocritical care unit. Currently, micro-oxygen-electrodes are considered as the "gold standard" in measuring cerebral oxygen pressure (pO2 ), which is closely related to SO2 through the oxygen dissociation curve (ODC) of hemoglobin, but with the drawback of slow in response time. The present study suggests estimation of SO2 in brain tissue using diffuse reflectance spectroscopy (DRS) for finding an analytical relation between measured spectra and the SO2 for different blood concentrations. The P3 diffusion approximation is used to generate a set of spectra simulating brain tissue for various levels of blood concentrations in order to estimate SO2 . The algorithm is evaluated on optical phantoms mimicking white brain matter (blood volume of 0.5-2%) where pO2 and temperature is controlled and on clinical data collected during brain surgery. The suggested method is capable of estimating the blood fraction and oxygen saturation changes from the spectroscopic signal and the hemoglobin absorption profile.
Collapse
Affiliation(s)
- Peter Rejmstad
- Department of Biomedical Engineering, Linköping University, 581 83, LINKÖPING, Sweden
| | - Johannes D Johansson
- Department of Biomedical Engineering, Linköping University, 581 83, LINKÖPING, Sweden
| | - Neda Haj-Hosseini
- Department of Biomedical Engineering, Linköping University, 581 83, LINKÖPING, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, 581 83, LINKÖPING, Sweden
| |
Collapse
|
29
|
Richter JCO, Haj-Hosseini N, Hallbeck M, Wårdell K. Combination of hand-held probe and microscopy for fluorescence guided surgery in the brain tumor marginal zone. Photodiagnosis Photodyn Ther 2017; 18:185-192. [PMID: 28223144 DOI: 10.1016/j.pdpdt.2017.01.188] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Revised: 12/23/2016] [Accepted: 01/03/2017] [Indexed: 11/26/2022]
Abstract
BACKGROUND Visualization of the tumor is crucial for differentiating malignant tissue from healthy brain during surgery, especially in the tumor marginal zone. The aim of the study was to introduce a fluorescence spectroscopy-based hand-held probe (HHF-probe) for tumor identification in combination with the fluorescence guided resection surgical microscope (FGR-microscope), and evaluate them in terms of diagnostic performance and practical aspects of fluorescence detection. MATERIAL AND METHODS Eighteen operations were performed on 16 patients with suspected high-grade glioma. The HHF-probe and the FGR-microscope were used for detection of protoporphyrin (PpIX) fluorescence induced by 5-aminolevulinic acid (5-ALA) and evaluated against histopathological analysis and visual grading done through the FGR-microscope by the surgeon. A ratio of PpIX fluorescence intensity to the autofluorescence intensity (fluorescence ratio) was used to quantify the spectra detected by the probe. RESULTS Fluorescence ratio medians (range 0 - 40) measured by the probe were related to the intensity of the fluorescence in the FGR-microscope, categorized as "none" (0.3, n=131), "weak" (1.6, n=34) and "strong" (5.4, n=28). Of 131 "none" points in the FGR-microscope, 88 (67%) exhibited fluorescence with the HHF-probe. For the tumor marginal zone, the area under the receiver operator characteristics (ROC) curve was 0.49 for the FGR-microscope and 0.65 for the HHF-probe. CONCLUSIONS The probe was integrated in the established routine of tumor resection using the FGR-microscope. The HHF-probe was superior to the FGR-microscope in sensitivity; it detected tumor remnants after debulking under the FGR-microscope. The combination of the HHF-probe and the FGR-microscope was beneficial especially in the tumor marginal zone.
Collapse
Affiliation(s)
- Johan C O Richter
- Department of Biomedical Engineering, Linköping University, Sweden; Department of Neurosurgery Linköping University Hospital, Region Östergötland, Linköping, Sweden.
| | | | - Martin Hallbeck
- Department of Clinical Pathology and Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Sweden
| |
Collapse
|
30
|
Hemm S, Pison D, Alonso F, Shah A, Coste J, Lemaire JJ, Wårdell K. Patient-Specific Electric Field Simulations and Acceleration Measurements for Objective Analysis of Intraoperative Stimulation Tests in the Thalamus. Front Hum Neurosci 2016; 10:577. [PMID: 27932961 PMCID: PMC5122591 DOI: 10.3389/fnhum.2016.00577] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Accepted: 11/01/2016] [Indexed: 11/25/2022] Open
Abstract
Despite an increasing use of deep brain stimulation (DBS) the fundamental mechanisms of action remain largely unknown. Simulation of electric entities has previously been proposed for chronic DBS combined with subjective symptom evaluations, but not for intraoperative stimulation tests. The present paper introduces a method for an objective exploitation of intraoperative stimulation test data to identify the optimal implant position of the chronic DBS lead by relating the electric field (EF) simulations to the patient-specific anatomy and the clinical effects quantified by accelerometry. To illustrate the feasibility of this approach, it was applied to five patients with essential tremor bilaterally implanted in the ventral intermediate nucleus (VIM). The VIM and its neighborhood structures were preoperatively outlined in 3D on white matter attenuated inversion recovery MR images. Quantitative intraoperative clinical assessments were performed using accelerometry. EF simulations (n = 272) for intraoperative stimulation test data performed along two trajectories per side were set-up using the finite element method for 143 stimulation test positions. The resulting EF isosurface of 0.2 V/mm was superimposed to the outlined anatomical structures. The percentage of volume of each structure’s overlap was calculated and related to the corresponding clinical improvement. The proposed concept has been successfully applied to the five patients. For higher clinical improvements, not only the VIM but as well other neighboring structures were covered by the EF isosurfaces. The percentage of the volumes of the VIM, of the nucleus intermediate lateral of the thalamus and the prelemniscal radiations within the prerubral field of Forel increased for clinical improvements higher than 50% compared to improvements lower than 50%. The presented new concept allows a detailed and objective analysis of a high amount of intraoperative data to identify the optimal stimulation target. First results indicate agreement with published data hypothesizing that the stimulation of other structures than the VIM might be responsible for good clinical effects in essential tremor. (Clinical trial reference number: Ref: 2011-A00774-37/AU905)
Collapse
Affiliation(s)
- Simone Hemm
- Institute for Medical and Analytical Technologies, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland FHNWMuttenz, Switzerland; Department of Biomedical Engineering, Linköping UniversityLinköping, Sweden
| | - Daniela Pison
- Institute for Medical and Analytical Technologies, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland FHNW Muttenz, Switzerland
| | - Fabiola Alonso
- Department of Biomedical Engineering, Linköping University Linköping, Sweden
| | - Ashesh Shah
- Institute for Medical and Analytical Technologies, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland FHNW Muttenz, Switzerland
| | - Jérôme Coste
- Université Clermont Auvergne, Université d'Auvergne, EA 7282, Image Guided Clinical Neurosciences and Connectomics (IGCNC)Clermont-Ferrand, France; Service de Neurochirurgie, Hôpital Gabriel-Montpied, Centre Hospitalier Universitaire de Clermont-FerrandClermont-Ferrand, France
| | - Jean-Jacques Lemaire
- Université Clermont Auvergne, Université d'Auvergne, EA 7282, Image Guided Clinical Neurosciences and Connectomics (IGCNC)Clermont-Ferrand, France; Service de Neurochirurgie, Hôpital Gabriel-Montpied, Centre Hospitalier Universitaire de Clermont-FerrandClermont-Ferrand, France
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University Linköping, Sweden
| |
Collapse
|
31
|
Alonso F, Latorre MA, Göransson N, Zsigmond P, Wårdell K. Investigation into Deep Brain Stimulation Lead Designs: A Patient-Specific Simulation Study. Brain Sci 2016; 6:brainsci6030039. [PMID: 27618109 PMCID: PMC5039468 DOI: 10.3390/brainsci6030039] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 08/29/2016] [Accepted: 08/30/2016] [Indexed: 11/16/2022] Open
Abstract
New deep brain stimulation (DBS) electrode designs offer operation in voltage and current mode and capability to steer the electric field (EF). The aim of the study was to compare the EF distributions of four DBS leads at equivalent amplitudes (3 V and 3.4 mA). Finite element method (FEM) simulations (n = 38) around cylindrical contacts (leads 3389, 6148) or equivalent contact configurations (leads 6180, SureStim1) were performed using homogeneous and patient-specific (heterogeneous) brain tissue models. Steering effects of 6180 and SureStim1 were compared with symmetric stimulation fields. To make relative comparisons between simulations, an EF isolevel of 0.2 V/mm was chosen based on neuron model simulations (n = 832) applied before EF visualization and comparisons. The simulations show that the EF distribution is largely influenced by the heterogeneity of the tissue, and the operating mode. Equivalent contact configurations result in similar EF distributions. In steering configurations, larger EF volumes were achieved in current mode using equivalent amplitudes. The methodology was demonstrated in a patient-specific simulation around the zona incerta and a "virtual" ventral intermediate nucleus target. In conclusion, lead design differences are enhanced when using patient-specific tissue models and current stimulation mode.
Collapse
Affiliation(s)
- Fabiola Alonso
- Department of Biomedical Engineering, Linköping University, Linköping 58185, Sweden.
| | - Malcolm A Latorre
- Department of Biomedical Engineering, Linköping University, Linköping 58185, Sweden.
| | - Nathanael Göransson
- Department of Biomedical Engineering, Linköping University, Linköping 58185, Sweden.
- Department of Neurosurgery, Linköping University Hospital, Region Östergötland, Linköping 58185, Sweden.
| | - Peter Zsigmond
- Department of Neurosurgery, Linköping University Hospital, Region Östergötland, Linköping 58185, Sweden.
- Department of Clinical and Experimental Medicine, Linköping University, Linköping 58185, Sweden.
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping 58185, Sweden.
| |
Collapse
|
32
|
Wårdell K, Hemm-Ode S, Rejmstad P, Zsigmond P. High-Resolution Laser Doppler Measurements of Microcirculation in the Deep Brain Structures: A Method for Potential Vessel Tracking. Stereotact Funct Neurosurg 2016; 94:1-9. [PMID: 26795207 DOI: 10.1159/000442894] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2015] [Accepted: 11/30/2015] [Indexed: 11/19/2022]
Abstract
BACKGROUND Laser Doppler flowmetry (LDF) can be used to measure cerebral microcirculation in relation to stereotactic deep brain stimulation (DBS) implantations. OBJECTIVE To investigate the microcirculation and total light intensity (TLI) corresponding to tissue grayness in DBS target regions with high-resolution LDF recordings, and to define a resolution which enables detection of small vessels. METHODS Stereotactic LDF measurements were made prior to DBS implantation with 0.5-mm steps in the vicinity to 4 deep brain targets (STN, GPi, Vim, Zi) along 20 trajectories. The Mann-Whitney U test was used to compare the microcirculation and TLI between targets, and the measurement resolution (0.5 vs. 1 mm). The numbers of high blood flow spots along the trajectories were calculated. RESULTS There was a significant difference (p < 0.05) in microcirculation between the targets. High blood flow spots were present at 15 out of 510 positions, 7 along Vim and GPi trajectories, respectively. There was no statistical difference between resolutions even though both local blood flow and TLI peaks could appear at 0.5-mm steps. CONCLUSIONS LDF can be used for online tracking of critical regions presenting blood flow and TLI peaks, possibly relating to vessel structures and thin laminas along stereotactic trajectories.
Collapse
Affiliation(s)
- Karin Wårdell
- Department of Biomedical Engineering, Linkx00F6;ping University, Linkx00F6;ping, Sweden
| | | | | | | |
Collapse
|
33
|
Latorre MA, Chan ADC, Wårdell K. A physical action potential generator: design, implementation and evaluation. Front Neurosci 2015; 9:371. [PMID: 26539072 PMCID: PMC4611155 DOI: 10.3389/fnins.2015.00371] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2015] [Accepted: 09/22/2015] [Indexed: 11/13/2022] Open
Abstract
The objective was to develop a physical action potential generator (Paxon) with the ability to generate a stable, repeatable, programmable, and physiological-like action potential. The Paxon has an equivalent of 40 nodes of Ranvier that were mimicked using resin embedded gold wires (Ø = 20 μm). These nodes were software controlled and the action potentials were initiated by a start trigger. Clinically used Ag-AgCl electrodes were coupled to the Paxon for functional testing. The Paxon's action potential parameters were tunable using a second order mathematical equation to generate physiologically relevant output, which was accomplished by varying the number of nodes involved (1–40 in incremental steps of 1) and the node drive potential (0–2.8 V in 0.7 mV steps), while keeping a fixed inter-nodal timing and test electrode configuration. A system noise floor of 0.07 ± 0.01 μV was calculated over 50 runs. A differential test electrode recorded a peak positive amplitude of 1.5 ± 0.05 mV (gain of 40x) at time 196.4 ± 0.06 ms, including a post trigger delay. The Paxon's programmable action potential like signal has the possibility to be used as a validation test platform for medical surface electrodes and their attached systems.
Collapse
Affiliation(s)
- Malcolm A Latorre
- Department of Biomedical Engineering, Linköping University Linköping, Sweden
| | - Adrian D C Chan
- Department of Systems and Computer Engineering, Carleton University Ottawa, ON, Canada
| | - Karin Wårdell
- Department of Biomedical Engineering, Linköping University Linköping, Sweden
| |
Collapse
|
34
|
Wårdell K, Kefalopoulou Z, Diczfalusy E, Andersson M, Åström M, Limousin P, Zrinzo L, Hariz M. Deep Brain Stimulation of the Pallidum Internum for Gilles de la Tourette Syndrome: A Patient-Specific Model-Based Simulation Study of the Electric Field. Neuromodulation 2014; 18:90-6. [DOI: 10.1111/ner.12248] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2014] [Revised: 08/05/2014] [Accepted: 08/25/2014] [Indexed: 11/29/2022]
Affiliation(s)
- Karin Wårdell
- Department of Biomedical Engineering; Linköping University; Linköping Sweden
| | - Zinovia Kefalopoulou
- Unit of Functional Neurosurgery; Institute of Neurology; University College London; London UK
| | - Elin Diczfalusy
- Department of Biomedical Engineering; Linköping University; Linköping Sweden
| | - Mats Andersson
- Department of Biomedical Engineering; Linköping University; Linköping Sweden
| | - Mattias Åström
- Department of Biomedical Engineering; Linköping University; Linköping Sweden
| | - Patricia Limousin
- Unit of Functional Neurosurgery; Institute of Neurology; University College London; London UK
| | - Ludvic Zrinzo
- Unit of Functional Neurosurgery; Institute of Neurology; University College London; London UK
| | - Marwan Hariz
- Unit of Functional Neurosurgery; Institute of Neurology; University College London; London UK
- Department of Clinical Neuroscience; Umeå University; Umeå Sweden
| |
Collapse
|
35
|
Wårdell K, Zsigmond P, Richter J, Hemm S. Relationship between laser Doppler signals and anatomy during deep brain stimulation electrode implantation toward the ventral intermediate nucleus and subthalamic nucleus. Neurosurgery 2013. [PMID: 23190636 DOI: 10.1227/neu.0b013e31827e5821] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Deep brain stimulation (DBS) requires precise and safe navigation to the chosen target. Optical measurements allow monitoring of gray-white tissue boundaries (total light intensity [TLI]) and microvascular blood flow during stereotactic procedures. OBJECTIVE To establish the link between TLI/blood flow and anatomy along trajectories toward the ventral intermediate nucleus (Vim) and subthalamic nucleus (STN). METHODS Stereotactic laser Doppler measurements were obtained with millimeter precision from the cortex toward the Vim (n = 13) and STN (n = 9). Optical trajectories of TLI and blood flow were created and compared with anatomy by superimposing the Schaltenbrandt-Wahren atlas on the patients' pre- and postoperative images. Measurements were divided into anatomic subgroups and compared statistically. RESULTS Typical TLI trajectories with well-defined anatomic regions could be identified for the Vim and STN. TLI was significantly lower (P < .001) and microvascular blood flow significantly higher (P = .01) in the Vim targets. Of 1285 sites, 38 showed blood flow peaks, 27 of them along the Vim trajectories. High blood flow was more common close to the sulci and in the vicinity of the caudate/putamen. Along 1 Vim trajectory, a slight bleeding was suspected during insertion of the probe and confirmed with postoperative computed tomography. CONCLUSION Laser Doppler is useful for intraoperative guidance during DBS implantation because simultaneous measurement of tissue grayness and microvascular blood flow can be done along the trajectory with millimeter precision. Typical but different TLI trajectories were found for the Vim and STN.
Collapse
Affiliation(s)
- Karin Wårdell
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden.
| | | | | | | |
Collapse
|
36
|
Diczfalusy E, Dizdar N, Zsigmond P, Kullman A, Loyd D, Wårdell K. Simulations and visualizations for interpretation of brain microdialysis data during deep brain stimulation. Annu Int Conf IEEE Eng Med Biol Soc 2013; 2012:6438-41. [PMID: 23367403 DOI: 10.1109/embc.2012.6347468] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Microdialysis of the basal ganglia was used in parallel to deep brain stimulation (DBS) for patients with Parkinson's disease. The aim of this study was to patient-specifically simulate and visualize the maximum tissue volume of influence (TVI(max)) for each microdialysis catheter and the electric field generated around each DBS electrode. The finite element method (FEM) was used for the simulations. The method allowed mapping of the anatomical origin of the microdialysis data and the electric stimulation for each patient. It was seen that the sampling and stimulation targets differed among the patients, and the results will therefore be used in the future interpretation of the biochemical data.
Collapse
Affiliation(s)
- Elin Diczfalusy
- Department of Biomedical Engineering, Linköping University, Sweden.
| | | | | | | | | | | |
Collapse
|
37
|
Johansson JD, Wårdell K. Intracerebral quantitative chromophore estimation from reflectance spectra captured during deep brain stimulation implantation. J Biophotonics 2013; 6:435-45. [PMID: 22927367 DOI: 10.1002/jbio.201200055] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2012] [Revised: 06/20/2012] [Accepted: 07/09/2012] [Indexed: 05/02/2023]
Abstract
Quantification of blood fraction (f(blood)), blood oxygenation (S(O2)), melanin, lipofuscin and oxidised and reduced Cytochrome aa 3 and c was done from diffuse reflectance spectra captured in cortex, white matter, globus pallidus internus (GPi) and subthalamus during stereotactic implantations of 29 deep brain stimulation (DBS) electrodes with the aim of investigating whether the chromophores can give physiological information about the targets for DBS. Double-sided Mann-Whitney U-tests showed more lipofuscin in GPi compared to white matter and subthalamus (p < 0.05). Compared to the other structures, f(blood) was significantly higher in cortex (p < 0.05) and S(O2) lower in GPi (p < 0.05). Median values and range for f(blood) were 1.0 [0.2-6.0]% in the cortex, 0.3 [0.1-8.2]% in white matter, 0.2 [0.1-0.8]% in the GPi and 0.2 [0.1-11.7]% in the subthalamus. Corresponding values for S(O2) was 20 [0-81]% in the cortex, 29 [0-78]% in white matter, 0 [0-0]% in the GPi and 0 [0-92]% in the subthalamus. In conclusion, the measurements indicate very low oxygenation and blood volume for DBS patients, especially in the GPi. It would be of great interest to investigate whether this is due to the disease, the normal situation or an artefact of doing invasive measurements.
Collapse
|
38
|
Diczfalusy E, Andersson M, Wårdell K. A diffusion tensor-based finite element model of microdialysis in the deep brain. Comput Methods Biomech Biomed Engin 2013; 18:201-12. [DOI: 10.1080/10255842.2013.789103] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
39
|
Rejmstad P, Åkesson G, Hillman J, Wårdell K. A laser Doppler system for monitoring of intracerebral microcirculation. Annu Int Conf IEEE Eng Med Biol Soc 2013; 2012:1988-91. [PMID: 23366307 DOI: 10.1109/embc.2012.6346346] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A two-channel standard laser Doppler perfusion monitor has been adapted for intracerebral measurements. Software developed in Labview makes it possible to present the microvascular perfusion, total light intensity (TLI), heart rate and trend curves in real-time during surgery. A custom-made optical probe was designed in order to enable easy fixation during brain surgery. The constructed brain probe was evaluated and compared to a standard probe. Both probes presented similar feasibility when used for the skin recordings. In addition, evaluation was done in one patient in relation to tumor resection. Stable perfusion and TLI signals were immediately recorded when the probe was positioned in cerebral tissue. Movement artifacts were clearly seen when the probe was moved to a new site. Recordings in cortex and tumor border showed higher perfusion and lower TLI compared to measurements in subcortical white matter. The calculated heart rate estimate agreed well with the noted value from the electrocardiographic patient monitoring system.
Collapse
Affiliation(s)
- Peter Rejmstad
- Department of Biomedical Engineering, Linköping University, Sweden.
| | | | | | | |
Collapse
|
40
|
Fytagoridis A, Åström M, Wårdell K, Blomstedt P. Stimulation-induced side effects in the posterior subthalamic area: Distribution, characteristics and visualization. Clin Neurol Neurosurg 2013; 115:65-71. [DOI: 10.1016/j.clineuro.2012.04.015] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2011] [Revised: 04/14/2012] [Accepted: 04/26/2012] [Indexed: 11/24/2022]
|
41
|
Hemm-Ode S, Wårdell K. Correlation between laser Doppler measurements and anatomy during deep brain stimulation surgery. BIOMED ENG-BIOMED TE 2012. [DOI: 10.1515/bmt-2012-4327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
42
|
Hirabayashi H, Hariz MI, Wårdell K, Blomstedt P. Impact of Parameters of Radiofrequency Coagulation on Volume of Stereotactic Lesion in Pallidotomy and Thalamotomy. Stereotact Funct Neurosurg 2012; 90:307-15. [DOI: 10.1159/000338249] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2011] [Accepted: 02/29/2012] [Indexed: 11/19/2022]
|
43
|
Åström M, Lemaire JJ, Wårdell K. Influence of heterogeneous and anisotropic tissue conductivity on electric field distribution in deep brain stimulation. Med Biol Eng Comput 2011; 50:23-32. [DOI: 10.1007/s11517-011-0842-z] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2011] [Accepted: 11/07/2011] [Indexed: 11/27/2022]
|
44
|
Diczfalusy E, Zsigmond P, Dizdar N, Kullman A, Loyd D, Wårdell K. A model for simulation and patient-specific visualization of the tissue volume of influence during brain microdialysis. Med Biol Eng Comput 2011; 49:1459-69. [DOI: 10.1007/s11517-011-0841-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2011] [Accepted: 10/22/2011] [Indexed: 01/06/2023]
|
45
|
Richter JCO, Haj-Hosseini N, Andersson-Engel S, Wårdell K. Fluorescence spectroscopy measurements in ultrasonic navigated resection of malignant brain tumors. Lasers Surg Med 2011; 43:8-14. [PMID: 21254137 DOI: 10.1002/lsm.21022] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND AND OBJECTIVE Glioblastoma multiforme is a highly malignant primary brain tumor. It has no border but at best a marginal zone, however, invisible to the surgeon. An optical touch pointer (OTP) enabling differentiation of healthy and tumor tissue by means of fiber-optic fluorescence spectroscopy has been developed. In combination with an ultrasonic navigation system, the OTP may be used for demarcation of resectable tumor tissue. The aim of the study was to evaluate the clinical performance of OTP during surgery of malignant brain tumors. STUDY DESIGN/MATERIALS AND METHODS Nine patients were operated on with the standard surgical procedure, including white light microscopy and navigation. A total of 5 mg/kg bodyweight of 5-amino-levulin acid was orally administrated before surgery. The OTP was calibrated into the ultrasound-based navigation system and measurements were performed in tumor core and along the tumor border. The ratio between the protoporphyrin IX fluorescence at 635 nm and the autofluorescence was used for quantifications of data. Biopsies (n = 20), ultrasound images (n = 30), and visual inspection (n = 180) were compared to the fluorescence ratio. RESULTS/CONCLUSION Healthy and tumor tissue could be identified and differentiated with the OTP (P < 0.001). The fluorescence ratio in average was 0 outside the tumor and low in the gliotic edema zone around the tumor. It increased in the marginal zone and was highest in the solid tumor tissue. In the necrotic tissue, in the center of the tumor, the ratio in average was 0. The OTP can be used in combination with ultrasound-based navigation and may help to determine whether to resect otherwise not identifiable tissue.
Collapse
Affiliation(s)
- Johan C O Richter
- Department of Biomedical Engineering, Linköping University, Linköping 58185, Sweden.
| | | | | | | |
Collapse
|
46
|
Haj-Hosseini N, Richter J, Andersson-Engels S, Wårdell K. Optical touch pointer for fluorescence guided glioblastoma resection using 5-aminolevulinic acid. Lasers Surg Med 2010; 42:9-14. [PMID: 20077492 DOI: 10.1002/lsm.20868] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND AND OBJECTIVE Total tumor resection in patients with glioblastoma multiforme (GBM) is difficult to achieve due to the tumor's infiltrative way of growing and morphological similarity to the surrounding functioning brain tissue. The diagnosis is usually subjectively performed using a surgical microscope. The objective of this study was to develop and evaluate a hand-held optical touch pointer using a fluorescence spectroscopy system to quantitatively distinguish healthy from malignant brain tissue intraoperatively. STUDY DESIGN/MATERIALS AND METHODS A fluorescence spectroscopy system with pulsed modulation was designed considering optimum energy delivery to the tissue, minimal photobleaching of PpIX and omission of the ambient light background in the operating room (OR). 5-Aminolevulinic acid (5-ALA) of 5 mg/kg body weight was given to the patients with a presumed GBM prior to surgery. During the surgery a laser pulse at 405 nm was delivered to the tissue. PpIX in glioblastoma tumor cells assigned with peaks at 635 and 704 nm was detected using a fiber optical probe. RESULTS/CONCLUSION By using the pulsed fluorescence spectroscopy, PpIX fluorescence is quantitatively detected in the GBM. An effective suppression of low power lamp background from the recorded spectra in addition to a significant reduction of high power surgical lights is achieved.
Collapse
Affiliation(s)
- Neda Haj-Hosseini
- Department of Biomedical Engineering, Linköping University, Linköping 58185, Sweden.
| | | | | | | |
Collapse
|
47
|
Aström M, Tripoliti E, Hariz MI, Zrinzo LU, Martinez-Torres I, Limousin P, Wårdell K. Patient-specific model-based investigation of speech intelligibility and movement during deep brain stimulation. Stereotact Funct Neurosurg 2010; 88:224-33. [PMID: 20460952 PMCID: PMC3214825 DOI: 10.1159/000314357] [Citation(s) in RCA: 82] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2009] [Accepted: 03/04/2010] [Indexed: 11/19/2022]
Abstract
BACKGROUND/AIMS Deep brain stimulation (DBS) is widely used to treat motor symptoms in patients with advanced Parkinson's disease. The aim of this study was to investigate the anatomical aspects of the electric field in relation to effects on speech and movement during DBS in the subthalamic nucleus. METHODS Patient-specific finite element models of DBS were developed for simulation of the electric field in 10 patients. In each patient, speech intelligibility and movement were assessed during 2 electrical settings, i.e. 4 V (high) and 2 V (low). The electric field was simulated for each electrical setting. RESULTS Movement was improved in all patients for both high and low electrical settings. In general, high-amplitude stimulation was more consistent in improving the motor scores than low-amplitude stimulation. In 6 cases, speech intelligibility was impaired during high-amplitude electrical settings. Stimulation of part of the fasciculus cerebellothalamicus from electrodes positioned medial and/or posterior to the center of the subthalamic nucleus was recognized as a possible cause of the stimulation-induced dysarthria. CONCLUSION Special attention to stimulation-induced speech impairments should be taken in cases when active electrodes are positioned medial and/or posterior to the center of the subthalamic nucleus.
Collapse
Affiliation(s)
- Mattias Aström
- Department of Biomedical Engineering, Linköping University, Linköping, Sweden.
| | | | | | | | | | | | | |
Collapse
|
48
|
Johansson JD, Fredriksson I, Wårdell K, Eriksson O. Simulation of reflected light intensity changes during navigation and radio-frequency lesioning in the brain. J Biomed Opt 2009; 14:044040. [PMID: 19725751 DOI: 10.1117/1.3210781] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
An electrode with adjacent optical fibers for measurements during navigation and radio frequency lesioning in the brain is modeled for Monte Carlo simulations of light transport in brain tissue. Relative reflected light intensity at 780 nm, I780, from this electrode and probes with identical fiber configuration are simulated using the intensity from native white matter as reference. Models are made of homogeneous native and coagulated gray, thalamus, and white matter as well as blood. Dual layer models, including models with a layer of cerebrospinal fluid between the fibers and the brain tissue, are also made. Simulated I780 was 0.16 for gray matter, 0.67 for coagulate gray matter, 0.36 for thalamus, 0.39 for coagulated thalamus, unity for white matter, 0.70 for coagulated white matter, and 0.24 for blood. Thalamic matter is also found to reflect more light than gray matter and less than white matter in clinical studies. In conclusion, the reflected light intensity can be used to differentiate between gray and white matter during navigation. Furthermore, coagulation of light gray tissue, such as the thalamus, might be difficult to detect using I780, but coagulation in darker gray tissue should result in a rapid increase of I780.
Collapse
Affiliation(s)
- Johannes D Johansson
- Linkoping University, Department of Biomedical Engineering, S-581 85 Linkoping, Sweden.
| | | | | | | |
Collapse
|
49
|
Johansson JD, Blomstedt P, Haj-Hosseini N, Bergenheim AT, Eriksson O, Wårdell K. Combined diffuse light reflectance and electrical impedance measurements as a navigation aid in deep brain surgery. Stereotact Funct Neurosurg 2009; 87:105-13. [PMID: 19223697 DOI: 10.1159/000202977] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
AIM The aim of this study is to assess reflected light intensity combined with impedance as a navigation aid during stereotactic neurosurgery. METHODS During creation of 21 trajectories for stereotactic implantation of deep brain stimulation electrodes in the globus pallidus internus or subthalamus (zona incerta or subthalamic nucleus), impedance at 512 kHz and reflected light intensity at 780 nm were measured continuously and simultaneously with a radio frequency electrode containing optical fibres. The signals were compared with the anatomy, determined from pre- and post-operative MRI and CT. The measurements were performed within minutes, and signal analysis was done post-operatively. RESULTS Reflected light intensity was low from the cortex, lateral ventricle, caudate nucleus and putamen; intermediate from the globus pallidus and thalamus; while it was high from the subcortical white matter, internal capsule and subthalamus. The electrical impedance was less consistent, but generally low in the cortex, intermediate in the subcortical white matter, putamen, globus pallidus and thalamus, and high in the internal capsule and subthalamus. CONCLUSION Reflected light intensity and electrical impedance give complementary information about passed tissue, and the combination seems promising as a navigation aid during stereotactic neurosurgery.
Collapse
|
50
|
Aström M, Zrinzo LU, Tisch S, Tripoliti E, Hariz MI, Wårdell K. Method for patient-specific finite element modeling and simulation of deep brain stimulation. Med Biol Eng Comput 2008; 47:21-8. [PMID: 18936999 DOI: 10.1007/s11517-008-0411-2] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2008] [Accepted: 09/26/2008] [Indexed: 11/30/2022]
Abstract
Deep brain stimulation (DBS) is an established treatment for Parkinson's disease. Success of DBS is highly dependent on electrode location and electrical parameter settings. The aim of this study was to develop a general method for setting up patient-specific 3D computer models of DBS, based on magnetic resonance images, and to demonstrate the use of such models for assessing the position of the electrode contacts and the distribution of the electric field in relation to individual patient anatomy. A software tool was developed for creating finite element DBS-models. The electric field generated by DBS was simulated in one patient and the result was visualized with isolevels and glyphs. The result was evaluated and it corresponded well with reported effects and side effects of stimulation. It was demonstrated that patient-specific finite element models and simulations of DBS can be useful for increasing the understanding of the clinical outcome of DBS.
Collapse
Affiliation(s)
- Mattias Aström
- Department of Biomedical Engineering, Linköping University, 58185 Linköping, Sweden.
| | | | | | | | | | | |
Collapse
|