1
|
Jie H, Wang Y, Zhao M, Wang X, Wang Z, Zeng L, Cao X, Xu T, Xia F, Liu Q. Automatic ultrasensitive lateral flow immunoassay based on a color-enhanced signal amplification strategy. Biosens Bioelectron 2024; 256:116262. [PMID: 38621340 DOI: 10.1016/j.bios.2024.116262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 02/27/2024] [Accepted: 03/29/2024] [Indexed: 04/17/2024]
Abstract
Lateral flow immunoassays (LFIAs) are an essential and widely used point-of-care test for medical diagnoses. However, commercial LFIAs still have low sensitivity and specificity. Therefore, we developed an automatic ultrasensitive dual-color enhanced LFIA (DCE-LFIA) by applying an enzyme-induced tyramide signal amplification method to a double-antibody sandwich LFIA for antigen detection. The DCE-LFIA first specifically captured horseradish peroxidase (HRP)-labeled colored microspheres at the Test line, and then deposited a large amount of tyramide-modified signals under the catalytic action of HRP to achieve the color superposition. A limit of detection (LOD) of 3.9 pg/mL and a naked-eye cut-off limit of 7.8 pg/mL were achieved for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleoprotein. Additionally, in the inactivated virus detections, LOD equivalent to chemiluminescence (0.018 TCID50/mL) was obtained, and it had excellent specificity under the interference of other respiratory viruses. High sensitivity has also been achieved for detection of influenza A, influenza B, cardiac troponin I, and human chorionic gonadotrophin using this DCE-LFIA, suggesting the assay is universally applicable. To ensure the convenience and stability in practical applications, we created an automatic device. It provides a new practical option for point-of-care test immunoassays, especially ultra trace detection and at-home testing.
Collapse
Affiliation(s)
- Huiyang Jie
- Department of Detection and Diagnosis Technology Research, Guangzhou National Laboratory, Guangzhou, Guangdong, 510000, PR China
| | - Yu Wang
- Department of Detection and Diagnosis Technology Research, Guangzhou National Laboratory, Guangzhou, Guangdong, 510000, PR China
| | - Meng Zhao
- Micro-nano Tech Center, Bioland Laboratory, Guangzhou, Guangdong, 510000, PR China
| | - Xiuzhen Wang
- Department of Detection and Diagnosis Technology Research, Guangzhou National Laboratory, Guangzhou, Guangdong, 510000, PR China
| | - Zhong Wang
- Department of Detection and Diagnosis Technology Research, Guangzhou National Laboratory, Guangzhou, Guangdong, 510000, PR China
| | - Lingliao Zeng
- Department of Detection and Diagnosis Technology Research, Guangzhou National Laboratory, Guangzhou, Guangdong, 510000, PR China
| | - Xiaobao Cao
- Department of Detection and Diagnosis Technology Research, Guangzhou National Laboratory, Guangzhou, Guangdong, 510000, PR China.
| | - Tao Xu
- Department of Detection and Diagnosis Technology Research, Guangzhou National Laboratory, Guangzhou, Guangdong, 510000, PR China; School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, 511436, PR China
| | - Fan Xia
- Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan, Hubei, 430074, PR China
| | - Qian Liu
- Department of Detection and Diagnosis Technology Research, Guangzhou National Laboratory, Guangzhou, Guangdong, 510000, PR China; School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, 511436, PR China.
| |
Collapse
|
2
|
Lane D, Allsopp R, Holmes CW, Slingsby OC, Jukes-Jones R, Bird P, Anderson NL, Razavi M, Yip R, Pearson TW, Pope M, Khunti K, Doykov I, Hällqvist J, Mills K, Skipp P, Carling R, Ng L, Shaw J, Gupta P, Jones DJL. A high throughput immuno-affinity mass spectrometry method for detection and quantitation of SARS-CoV-2 nucleoprotein in human saliva and its comparison with RT-PCR, RT-LAMP, and lateral flow rapid antigen test. Clin Chem Lab Med 2024; 62:1206-1216. [PMID: 38253336 DOI: 10.1515/cclm-2023-0243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 12/12/2023] [Indexed: 01/24/2024]
Abstract
OBJECTIVES Many reverse transcription polymerase chain reaction (RT-PCR) methods exist that can detect SARS-CoV-2 RNA in different matrices. RT-PCR is highly sensitive, although viral RNA may be detected long after active infection has taken place. SARS-CoV-2 proteins have shorter detection windows hence their detection might be more meaningful. Given salivary droplets represent a main source of transmission, we explored the detection of viral RNA and protein using four different detection platforms including SISCAPA peptide immunoaffinity liquid chromatography-mass spectrometry (SISCAPA-LC-MS) using polyclonal capture antibodies. METHODS The SISCAPA-LC MS method was compared to RT-PCR, RT-loop-mediated isothermal amplification (RT-LAMP), and a lateral flow rapid antigen test (RAT) for the detection of virus material in the drool saliva of 102 patients hospitalised after infection with SARS-CoV-2. Cycle thresholds (Ct) of RT-PCR (E gene) were compared to RT-LAMP time-to-positive (TTP) (NE and Orf1a genes), RAT optical densitometry measurements (test line/control line ratio) and to SISCAPA-LC-MS for measurements of viral protein. RESULTS SISCAPA-LC-MS showed low sensitivity (37.7 %) but high specificity (89.8 %). RAT showed lower sensitivity (24.5 %) and high specificity (100 %). RT-LAMP had high sensitivity (83.0 %) and specificity (100.0 %). At high initial viral RNA loads (<20 Ct), results obtained using SISCAPA-LC-MS correlated with RT-PCR (R2 0.57, p-value 0.002). CONCLUSIONS Detection of SARS-CoV-2 nucleoprotein in saliva was less frequent than the detection of viral RNA. The SISCAPA-LC-MS method allowed processing of multiple samples in <150 min and was scalable, enabling high throughput.
Collapse
Affiliation(s)
- Dan Lane
- The Department of Chemical Pathology and Metabolic Diseases, Leicester Royal Infirmary, University Hospitals of Leicester, Leicester, UK
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK
| | - Rebecca Allsopp
- Department of Genetics and Genome Biology, Leicester Cancer Research Centre, University of Leicester, Leicester, UK
| | - Christopher W Holmes
- Clinical Microbiology, Leicester Royal Infirmary, University Hospitals of Leicester NHS Trust, Leicester, UK
| | | | - Rebekah Jukes-Jones
- The Department of Chemical Pathology and Metabolic Diseases, Leicester Royal Infirmary, University Hospitals of Leicester, Leicester, UK
| | - Paul Bird
- Clinical Microbiology, Leicester Royal Infirmary, University Hospitals of Leicester NHS Trust, Leicester, UK
| | | | | | - Richard Yip
- SISCAPA Assay Technologies, Inc., Washington, DC, USA
| | | | - Matt Pope
- SISCAPA Assay Technologies, Inc., Washington, DC, USA
| | - Kamlesh Khunti
- Leicester Diabetes Centre, Leicester General Hospital, University of Leicester, Leicester, UK
| | - Ivan Doykov
- Genetics & Genomic Medicine Department, Translational Mass Spectrometry Research Group, UCL Institute of Child Health, London, UK
- Great Ormond Street Biomedical Research Centre, UCL Institute of Child Health, London, UK
| | - Jenny Hällqvist
- Genetics & Genomic Medicine Department, Translational Mass Spectrometry Research Group, UCL Institute of Child Health, London, UK
- Great Ormond Street Biomedical Research Centre, UCL Institute of Child Health, London, UK
| | - Kevin Mills
- Genetics & Genomic Medicine Department, Translational Mass Spectrometry Research Group, UCL Institute of Child Health, London, UK
- Great Ormond Street Biomedical Research Centre, UCL Institute of Child Health, London, UK
| | - Paul Skipp
- Centre for Proteomic Research, University of Southampton, Southampton, UK
| | - Rachel Carling
- Biochemical Sciences, Synnovis, Guys & St Thomas' NHSFT, London, UK
- GKT School Medical Education, Kings College London, London, UK
| | - Leong Ng
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK
- van Geest MS-OMICS Facility, University of Leicester, Leicester, UK
| | - Jacqui Shaw
- Department of Genetics and Genome Biology, Leicester Cancer Research Centre, University of Leicester, Leicester, UK
| | - Pankaj Gupta
- The Department of Chemical Pathology and Metabolic Diseases, Leicester Royal Infirmary, University Hospitals of Leicester, Leicester, UK
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK
| | - Donald J L Jones
- Department of Genetics and Genome Biology, Leicester Cancer Research Centre, University of Leicester, Leicester, UK
- van Geest MS-OMICS Facility, University of Leicester, Leicester, UK
| |
Collapse
|
3
|
Haghayegh F, Salahandish R, Hassani M, Sanati-Nezhad A. Highly Stable Buffer-Based Zinc Oxide/Reduced Graphene Oxide Nanosurface Chemistry for Rapid Immunosensing of SARS-CoV-2 Antigens. ACS Appl Mater Interfaces 2022; 14:10844-10855. [PMID: 35172574 DOI: 10.1021/acsami.1c24475] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The widespread and long-lasting effect of the COVID-19 pandemic has called attention to the significance of technological advances in the rapid diagnosis of SARS-CoV-2 virus. This study reports the use of a highly stable buffer-based zinc oxide/reduced graphene oxide (bbZnO/rGO) nanocomposite coated on carbon screen-printed electrodes for electrochemical immuno-biosensing of SARS-CoV-2 nuelocapsid (N-) protein antigens in spiked and clinical samples. The incorporation of a salt-based (ionic) matrix for uniform dispersion of the nanomixture eliminates multistep nanomaterial synthesis on the surface of the electrode and enables a stable single-step sensor nanocoating. The immuno-biosensor provides a limit of detection of 21 fg/mL over a linear range of 1-10 000 pg/mL and exhibits a sensitivity of 32.07 ohms·mL/pg·mm2 for detection of N-protein in spiked samples. The N-protein biosensor is successful in discriminating positive and negative clinical samples within 15 min, demonstrating its proof of concept used as a COVID-19 rapid antigen test.
Collapse
Affiliation(s)
- Fatemeh Haghayegh
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4, Canada
| | - Razieh Salahandish
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4, Canada
- Center for BioEngineering Research and Education, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| | - Mohsen Hassani
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4, Canada
| | - Amir Sanati-Nezhad
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4, Canada
- Center for BioEngineering Research and Education, University of Calgary, Calgary, Alberta T2N 1N4, Canada
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| |
Collapse
|
4
|
Bäuerl C, Randazzo W, Sánchez G, Selma-Royo M, García Verdevio E, Martínez L, Parra-Llorca A, Lerin C, Fumadó V, Crovetto F, Crispi F, Pérez-Cano FJ, Rodríguez G, Ruiz-Redondo G, Campoy C, Martínez-Costa C, Collado MC. SARS-CoV-2 RNA and antibody detection in breast milk from a prospective multicentre study in Spain. Arch Dis Child Fetal Neonatal Ed 2022; 107:216-221. [PMID: 34417223 DOI: 10.1101/2021.05.06.21256766] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Accepted: 07/12/2021] [Indexed: 05/21/2023]
Abstract
OBJECTIVES To develop and validate a specific protocol for SARS-CoV-2 detection in breast milk matrix and to determine the impact of maternal SARS-CoV-2 infection on the presence, concentration and persistence of specific SARS-CoV-2 antibodies. DESIGN AND PATIENTS This is a prospective, multicentre longitudinal study (April-December 2020) in 60 mothers with SARS-CoV-2 infection and/or who have recovered from COVID-19. A control group of 13 women before the pandemic were also included. SETTING Seven health centres from different provinces in Spain. MAIN OUTCOME MEASURES Presence of SARS-CoV-2 RNA in breast milk, targeting the N1 region of the nucleocapsid gene and the envelope (E) gene; presence and levels of SARS-CoV-2-specific immunoglobulins (Igs)-IgA, IgG and IgM-in breast milk samples from patients with COVID-19. RESULTS All breast milk samples showed negative results for presence of SARS-CoV-2 RNA. We observed high intraindividual and interindividual variability in the antibody response to the receptor-binding domain of the SARS-CoV-2 spike protein for each of the three isotypes IgA, IgM and IgG. Main Protease (MPro) domain antibodies were also detected in milk. 82.9% (58 of 70) of milk samples were positive for at least one of the three antibody isotypes, with 52.9% of these positive for all three Igs. Positivity rate for IgA was relatively stable over time (65.2%-87.5%), whereas it raised continuously for IgG (from 47.8% for the first 10 days to 87.5% from day 41 up to day 206 post-PCR confirmation). CONCLUSIONS Our study confirms the safety of breast feeding and highlights the relevance of virus-specific SARS-CoV-2 antibody transfer. This study provides crucial data to support official breastfeeding recommendations based on scientific evidence. Trial registration number NCT04768244.
Collapse
Affiliation(s)
- Christine Bäuerl
- Department of Biotechnology, Institute of Agrochemistry and Food Technology-National Research Council (IATA-CSIC), Paterna, Valencia, Spain
| | - Walter Randazzo
- Department of Preservation and Food Safety Technologies, Institute of Agrochemistry and Food Technology-National Research Council (IATA-CSIC), Paterna, Valencia, Spain
| | - Gloria Sánchez
- Department of Preservation and Food Safety Technologies, Institute of Agrochemistry and Food Technology-National Research Council (IATA-CSIC), Paterna, Valencia, Spain
| | - Marta Selma-Royo
- Department of Biotechnology, Institute of Agrochemistry and Food Technology-National Research Council (IATA-CSIC), Paterna, Valencia, Spain
| | - Elia García Verdevio
- Department of Gynecology and Obstetrics, Hospital Universitario Dr Peset, Valencia, Spain
| | - Laura Martínez
- Department of Paediatrics, Hospital Clínico Universitario de Valencia, Nutrition Research Group of INCLIVA, Valencia, Spain
| | - Anna Parra-Llorca
- Health Research Institute La Fe, Neonatal Research Group and University and Polytechnic Hospital La Fe, Division of Neonatology, Valencia, Spain
| | - Carles Lerin
- Department of Endocrinology, Institut de Recerca Sant Joan de Déu, Hospital Sant Joan de Déu, Barcelona, Spain
| | - Victoria Fumadó
- Department of Infectious and Imported Diseases, Paediatric Unit, Institut de Recerca Sant Joan de Déu, Hospital Sant Joan de Déu, Barcelona, Spain
| | - Francesca Crovetto
- BCNatal - Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Sant Joan de Déu and Hospital Clínic, University of Barcelona, CIBERER, Barcelona, Spain
| | - Fatima Crispi
- BCNatal - Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Sant Joan de Déu and Hospital Clínic, University of Barcelona, CIBERER, Barcelona, Spain
| | - Francisco J Pérez-Cano
- Department of Biochemistry and Physiology, Faculty of Pharmacy and Food Science, University of Barcelona, Barcelona, Spain
| | - Gerardo Rodríguez
- University of Zaragoza, Hospital Clínico Universitario Lozano Blesa, Zaragoza. Instituto de Investigación Sanitaria Aragón (IIS Aragón), Red de Salud Materno Infantil y del Desarrollo (SAMID), Zaragoza, Spain
| | - Gemma Ruiz-Redondo
- Department of Gynecology and Obstetrics, University Hospital Clinic "San Cecilio" - Health Sciences Technological Park (PTS), Granada, Spain
| | - Cristina Campoy
- Department of Paediatrics, University of Granada, Granada, Spain
| | - Cecilia Martínez-Costa
- Department of Paediatrics, Hospital Clínico Universitario de Valencia, Nutrition Research Group of INCLIVA, Valencia, Spain
| | - Maria Carmen Collado
- Department of Biotechnology, Institute of Agrochemistry and Food Technology-National Research Council (IATA-CSIC), Paterna, Valencia, Spain
| |
Collapse
|
5
|
Tuite AR, Fisman D, Abe KT, Rathod B, Pasculescu A, Colwill K, Gingras AC, Yi QL, O’Brien SF, Drews SJ. Estimating SARS-CoV-2 Seroprevalence in Canadian Blood Donors, April 2020 to March 2021: Improving Accuracy with Multiple Assays. Microbiol Spectr 2022; 10:e0256321. [PMID: 35196819 PMCID: PMC8865569 DOI: 10.1128/spectrum.02563-21] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Accepted: 01/14/2022] [Indexed: 01/30/2023] Open
Abstract
We have previously used composite reference standards and latent class analysis (LCA) to evaluate the performance of laboratory assays in the presence of tarnished gold standards. Here, we apply these techniques to repeated, cross-sectional study of Canadian blood donors, whose sera underwent parallel testing with four separate SARS-CoV-2 antibody assays. We designed a repeated cross-sectional design with random cross-sectional sampling of all available retention samples (n = 1500/month) for a 12 -month period from April 2020 until March 2021. Each sample was evaluated for SARS-CoV-2 IgG antibodies using four assays an Abbott Architect assay targeting the nucleocapsid antigen (Abbott-NP, Abbott, Chicago IL) and three in-house IgG ELISAs recognizing distinct recombinant viral antigens: full-length spike glycoprotein (Spike), spike glycoprotein receptor binding domain (RBD) and nucleocapsid (NP). We used two analytic approaches to estimate SAR-CoV-2 seroprevalence: a composite reference standard and LCA. Using LCA to estimate true seropositivity status based on the results of the four antibody tests, we estimated that seroprevalence increased from 0.8% (95% CI: 0.5-1.4%) in April 2020 to 6.3% (95% CI: 5.1-7.6%) in March 2021. Our study provides further support for the use of LCA in upcoming public health crises, epidemics, and pandemics when a gold standard assay may not be available or identifiable. IMPORTANCE Here, we describe an approach to estimating seroprevalence in a low prevalence setting when multiple assays are available and yet no known gold standard exists. Because serological studies identify cases through both diagnostic testing and surveillance, and otherwise silent, unrecognized infections, serological data can be used to estimate the true infection fatality ratio of a disease. However, seroprevalence studies rely on assays with imperfect sensitivity and specificity. Seroreversion (loss of antibody response) also occurs over time, and with the advent of vaccination, distinction of antibody response resulting from vaccination as opposed to antibody response due to infection has posed an additional challenge. Our approach indicates that seroprevalence on Canadian blood donors by the end of March 2021was less than 10%. Our study supports the use of latent class analysis in upcoming public health crises, epidemics, and pandemics when a gold standard assay may not be available or identifiable.
Collapse
Affiliation(s)
- Ashleigh R. Tuite
- Dalla Lana School of Public Health, University of Toronto, Toronto, Ontario, Canada
- Centre for Immunization Readiness, Public Health Agency of Canada, Ottawa, Ontario, Canada
| | - David Fisman
- Dalla Lana School of Public Health, University of Toronto, Toronto, Ontario, Canada
| | - Kento T. Abe
- Lunenfeld-Tanenbaum Research Institute at Mt. Sinai Hospital, Sinai Health, Toronto, Ontario, Canada
- Department of Molecular Genetics, University of Toronto, Toronto, Ontario, Canada
| | - Bhavisha Rathod
- Lunenfeld-Tanenbaum Research Institute at Mt. Sinai Hospital, Sinai Health, Toronto, Ontario, Canada
| | - Adrian Pasculescu
- Lunenfeld-Tanenbaum Research Institute at Mt. Sinai Hospital, Sinai Health, Toronto, Ontario, Canada
| | - Karen Colwill
- Lunenfeld-Tanenbaum Research Institute at Mt. Sinai Hospital, Sinai Health, Toronto, Ontario, Canada
| | - Anne-Claude Gingras
- Lunenfeld-Tanenbaum Research Institute at Mt. Sinai Hospital, Sinai Health, Toronto, Ontario, Canada
- Department of Molecular Genetics, University of Toronto, Toronto, Ontario, Canada
| | - Qi-Long Yi
- Epidemiology and Surveillance, Canadian Blood Services, Ottawa, Ontario, Canada
- School of Epidemiology and Public Health, University of Ottawa, Ottawa, Ontario, Canada
| | - Sheila F. O’Brien
- Epidemiology and Surveillance, Canadian Blood Services, Ottawa, Ontario, Canada
- School of Epidemiology and Public Health, University of Ottawa, Ottawa, Ontario, Canada
| | - Steven J. Drews
- Canadian Blood Services, Microbiology, Edmonton, Alberta, Canada
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
6
|
Abstract
Patients with chronic lung disease are vulnerable to getting severe diseases associated with SARS-CoV-2 infection. Here, we describe protocols for subculturing and differentiating primary normal human bronchial epithelial (NHBE) cells of patients with chronic obstructive lung disease. The differentiation of NHBE cells in air-liquid interface mimics an in vivo airway and provides an in vitro model for studying SARS-CoV-2 infection. We also describe a protocol for detecting proteins in the sectioned epithelium for detailing SARS-CoV-2 infection-induced pathobiology with a vertical view.
Collapse
Affiliation(s)
- Jaspreet Kaur Osan
- Department of Biomedical Sciences, University of North Dakota School of Medicine & Health Sciences, Grand Forks, ND 58202, USA
| | - Beth Ann DeMontigny
- Department of Biomedical Sciences, University of North Dakota School of Medicine & Health Sciences, Grand Forks, ND 58202, USA
| | - Masfique Mehedi
- Department of Biomedical Sciences, University of North Dakota School of Medicine & Health Sciences, Grand Forks, ND 58202, USA
| |
Collapse
|
7
|
Wang C, Cheng X, Liu L, Zhang X, Yang X, Zheng S, Rong Z, Wang S. Ultrasensitive and Simultaneous Detection of Two Specific SARS-CoV-2 Antigens in Human Specimens Using Direct/Enrichment Dual-Mode Fluorescence Lateral Flow Immunoassay. ACS Appl Mater Interfaces 2021; 13:40342-40353. [PMID: 34412466 PMCID: PMC8386037 DOI: 10.1021/acsami.1c11461] [Citation(s) in RCA: 60] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 08/12/2021] [Indexed: 05/18/2023]
Abstract
Sensitive point-of-care methods for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigens in clinical specimens are urgently needed to achieve rapid screening of viral infection. We developed a magnetic quantum dot-based dual-mode lateral flow immunoassay (LFIA) biosensor for the high-sensitivity simultaneous detection of SARS-CoV-2 spike (S) and nucleocapsid protein (NP) antigens, which is beneficial for improving the detection accuracy and efficiency of SARS-CoV-2 infection in the point-of-care testing area. A high-performance magnetic quantum dot with a triple-QD shell (MagTQD) nanotag was first fabricated and integrated into the LFIA system to provide superior fluorescence signals, enrichment ability, and detectability for S/NP antigen testing. Two detection modes were provided by the proposed MagTQD-LFIA. The direct mode was used for rapid screening or urgent detection of suspected samples within 10 min, and the enrichment mode was used for the highly sensitive and quantitative analysis of SARS-CoV-2 antigens in biological samples without the interference of the "hook effect." The simultaneous detection of SARS-CoV-2 S/NP antigens was conducted in one LFIA strip, and the detection limits for two antigens under direct and enrichment modes were 1 and 0.5 pg/mL, respectively. The MagTQD-LFIA showed high accuracy, specificity, and stability in saliva and nasal swab samples and is an efficient tool with flexibility to meet the testing requirements for SARS-CoV-2 antigens in various situations.
Collapse
Affiliation(s)
- Chongwen Wang
- College
of Life Sciences, Anhui Agricultural University, Hefei 230036, P. R. China
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
- Beijing
Key Laboratory of New Molecular Diagnosis Technologies for Infectious
Diseases, Beijing 100850, P. R. China
| | - Xiaodan Cheng
- College
of Life Sciences, Anhui Agricultural University, Hefei 230036, P. R. China
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
| | - Liyan Liu
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
| | - Xiaochang Zhang
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
| | - Xingsheng Yang
- College
of Life Sciences, Anhui Agricultural University, Hefei 230036, P. R. China
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
| | - Shuai Zheng
- College
of Life Sciences, Anhui Agricultural University, Hefei 230036, P. R. China
| | - Zhen Rong
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
| | - Shengqi Wang
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
- Beijing
Key Laboratory of New Molecular Diagnosis Technologies for Infectious
Diseases, Beijing 100850, P. R. China
| |
Collapse
|
8
|
Rusanen J, Kareinen L, Szirovicza L, Uğurlu H, Levanov L, Jääskeläinen A, Ahava M, Kurkela S, Saksela K, Hedman K, Vapalahti O, Hepojoki J. A Generic, Scalable, and Rapid Time-Resolved Förster Resonance Energy Transfer-Based Assay for Antigen Detection-SARS-CoV-2 as a Proof of Concept. mBio 2021; 12:e00902-21. [PMID: 34006662 PMCID: PMC8262888 DOI: 10.1128/mbio.00902-21] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 04/19/2021] [Indexed: 01/30/2023] Open
Abstract
The ongoing coronavirus disease 2019 (COVID-19) pandemic has seen an unprecedented increase in the demand for rapid and reliable diagnostic tools, leaving many laboratories scrambling for resources. We present a fast and simple assay principle for antigen detection and demonstrate its functionality by detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigens in nasopharyngeal swabs. The method is based on the detection of SARS-CoV-2 nucleoprotein (NP) and S protein (SP) via time-resolved Förster resonance energy transfer (TR-FRET) with donor- and acceptor-labeled polyclonal anti-NP and -SP antibodies. Using recombinant proteins and cell culture-grown SARS-CoV-2, the limits of detection were established as 25 pg of NP or 20 infectious units (IU) and 875 pg of SP or 625 IU. Testing reverse transcription-PCR (RT-PCR)-positive (n = 48, with cycle threshold [CT ] values from 11 to 30) or -negative (n = 96) nasopharyngeal swabs demonstrated that the assay yielded positive results for all samples with CT values of <25 and for a single RT-PCR-negative sample. Virus isolation from the RT-PCR-positive nasopharyngeal swabs showed a strong association between the presence of infectious virus and a positive antigen test result. The NP-based assay showed 97.4% (37/38) sensitivity and 100% (10/10) specificity in comparison with virus isolation and 77.1% (37/48) sensitivity and 99.0% (95/96) specificity in comparison with SARS-CoV-2 RT-PCR. The assay is performed in a buffer that neutralizes SARS-CoV-2 infectivity, and the assay is relatively simple to set up as an "in-house" test. Here, SARS-CoV-2 served as the model pathogen, but the assay principle is applicable to other viral infections, and the test format could easily be adapted to high-throughput testing.IMPORTANCE PCR is currently the gold standard for the diagnosis of many acute infections. While PCR and its variants are highly sensitive and specific, the time from sampling to results is measured in hours at best. Antigen tests directly detect parts of the infectious agent, which may enable faster diagnosis but often at lower sensitivity and specificity. Here, we describe a technique for rapid antigen detection and demonstrate the test format's potential using SARS-CoV-2 as the model pathogen. The 10-min test, performed in a buffer that readily inactivates SARS-CoV-2, from nasopharyngeal samples identified 97.4% (37/38) of the samples from which we could isolate the virus. This suggests that the test performs well in identifying patients potentially shedding the virus. Although SARS-CoV-2 served as the model pathogen to demonstrate proof of concept, the test principle itself would be applicable to a wide variety of infectious and perhaps also noninfectious diseases.
Collapse
Affiliation(s)
- Juuso Rusanen
- University of Helsinki, Faculty of Medicine, Medicum, Department of Virology, Helsinki, Finland
| | - Lauri Kareinen
- University of Helsinki, Faculty of Medicine, Medicum, Department of Virology, Helsinki, Finland
- University of Helsinki, Faculty of Veterinary Medicine, Department of Veterinary Biosciences, Helsinki, Finland
| | - Leonora Szirovicza
- University of Helsinki, Faculty of Medicine, Medicum, Department of Virology, Helsinki, Finland
| | - Hasan Uğurlu
- University of Helsinki, Faculty of Medicine, Medicum, Department of Virology, Helsinki, Finland
| | - Lev Levanov
- University of Helsinki, Faculty of Medicine, Medicum, Department of Virology, Helsinki, Finland
| | - Anu Jääskeläinen
- HUS Diagnostic Center, HUSLAB, Clinical Microbiology, University of Helsinki, Helsinki, Finland
- Helsinki University Hospital, Helsinki, Finland
| | - Maarit Ahava
- HUS Diagnostic Center, HUSLAB, Clinical Microbiology, University of Helsinki, Helsinki, Finland
- Helsinki University Hospital, Helsinki, Finland
| | - Satu Kurkela
- HUS Diagnostic Center, HUSLAB, Clinical Microbiology, University of Helsinki, Helsinki, Finland
- Helsinki University Hospital, Helsinki, Finland
| | - Kalle Saksela
- University of Helsinki, Faculty of Medicine, Medicum, Department of Virology, Helsinki, Finland
| | - Klaus Hedman
- University of Helsinki, Faculty of Medicine, Medicum, Department of Virology, Helsinki, Finland
- HUS Diagnostic Center, HUSLAB, Clinical Microbiology, University of Helsinki, Helsinki, Finland
- Helsinki University Hospital, Helsinki, Finland
| | - Olli Vapalahti
- University of Helsinki, Faculty of Medicine, Medicum, Department of Virology, Helsinki, Finland
- University of Helsinki, Faculty of Veterinary Medicine, Department of Veterinary Biosciences, Helsinki, Finland
- HUS Diagnostic Center, HUSLAB, Clinical Microbiology, University of Helsinki, Helsinki, Finland
- Helsinki University Hospital, Helsinki, Finland
| | - Jussi Hepojoki
- University of Helsinki, Faculty of Medicine, Medicum, Department of Virology, Helsinki, Finland
- University of Zürich, Vetsuisse Faculty, Institute of Veterinary Pathology, Zürich, Switzerland
| |
Collapse
|
9
|
Mahmoudinobar F, Britton D, Montclare JK. Protein-based lateral flow assays for COVID-19 detection. Protein Eng Des Sel 2021; 34:gzab010. [PMID: 33991088 PMCID: PMC8194834 DOI: 10.1093/protein/gzab010] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 03/23/2021] [Accepted: 03/31/2021] [Indexed: 12/20/2022] Open
Abstract
To combat the enduring and dangerous spread of COVID-19, many innovations to rapid diagnostics have been developed based on proteinprotein interactions of the SARS-CoV-2 spike and nucleocapsid proteins to increase testing accessibility. These antigen tests have most prominently been developed using the lateral flow assay (LFA) test platform which has the benefit of administration at point-of-care, delivering quick results, lower cost, and does not require skilled personnel. However, they have gained criticism for an inferior sensitivity. In the last year, much attention has been given to creating a rapid LFA test for detection of COVID-19 antigens that can address its high limit of detection while retaining the advantages of rapid antibodyantigen interaction. In this review, a summary of these proteinprotein interactions as well as the challenges, benefits, and recent improvements to protein based LFA for detection of COVID-19 are discussed.
Collapse
Affiliation(s)
- Farbod Mahmoudinobar
- Department of Chemical and Biomolecular Engineering New York University Tandon School of Engineering, Brooklyn, NY 11201, USA
| | - Dustin Britton
- Department of Chemical and Biomolecular Engineering New York University Tandon School of Engineering, Brooklyn, NY 11201, USA
| | - Jin Kim Montclare
- Department of Chemical and Biomolecular Engineering New York University Tandon School of Engineering, Brooklyn, NY 11201, USA
- Department of Chemistry New York University, New York, NY 10003, USA
- Department of Biomaterials New York University College of Dentistry, New York, NY 10010, USA
- Department of Radiology New York University Langone Health, New York, NY 10016, USA
| |
Collapse
|
10
|
Sil BK, Jahan N, Haq MA, Oishee MJ, Ali T, Khandker SS, Kobatake E, Mie M, Khondoker MU, Jamiruddin MR, Adnan N. Development and performance evaluation of a rapid in-house ELISA for retrospective serosurveillance of SARS-CoV-2. PLoS One 2021; 16:e0246346. [PMID: 33529223 PMCID: PMC7853452 DOI: 10.1371/journal.pone.0246346] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Accepted: 01/16/2021] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND In the ongoing pandemic situation of COVID-19, serological tests can complement the molecular diagnostic methods, and can be one of the important tools of sero-surveillance and vaccine evaluation. AIM To develop and evaluate a rapid SARS-CoV-2 specific ELISA for detection of anti-SARS-CoV2 IgG from patients' biological samples. METHODS In order to develop this ELISA, three panels of samples (n = 184) have been used: panel 1 (n = 19) and panel 2 (n = 60) were collected from RT-PCR positive patients within 14 and after 14 days of onset of clinical symptoms, respectively; whereas panel 3 consisted of negative samples (n = 105) collected either from healthy donors or pre-pandemic dengue patients. As a capturing agent full-length SARS-CoV2 specific recombinant nucleocapsid was immobilized. Commercial SARS-CoV2 IgG kit based on chemiluminescent assay was used for the selection of samples and optimization of the assay. The threshold cut-off point, inter-assay and intra-assay variations were determined. RESULTS The incubation/reaction time was set at a total of 30 minutes with the sensitivity of 84% (95% confidence interval, CI, 60.4%, 96.6%) and 98% (95% CI, 91.1%, 100.0%), for panel 1 and 2, respectively; with overall 94.9% sensitivity (95% CI 87.5%, 98.6%). Moreover, the clinical specificity was 97.1% (95% CI, 91.9%, 99.4%) with no cross reaction with dengue samples. The overall positive and negative predictive values are 96.2% (95% CI 89.2%, 99.2%) and 96.2% (95% CI, 90.6% 99.0%), respectively. In-house ELISA demonstrated 100% positive and negative percent agreement with Elecsys Anti-SARS-CoV-2, with Cohen's kappa value of 1.00 (very strong agreement), while comparing 13 positive and 17 negative confirmed cases. CONCLUSION The assay is rapid and can be applied as one of the early and retrospective sero-monitoring tools in all over the affected areas.
Collapse
Affiliation(s)
- Bijon Kumar Sil
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka, Bangladesh
- Department of Microbiology, Gono Bishwabidyalay, Savar, Dhaka, Bangladesh
| | - Nowshin Jahan
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka, Bangladesh
| | - Md. Ahsanul Haq
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka, Bangladesh
| | - Mumtarin Jannat Oishee
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka, Bangladesh
- Department of Microbiology, Gono Bishwabidyalay, Savar, Dhaka, Bangladesh
| | - Tamanna Ali
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka, Bangladesh
| | - Shahad Saif Khandker
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka, Bangladesh
| | - Eiry Kobatake
- Department of Life Science and Technology, Tokyo Institute of Technology, Yokohama, Japan
| | - Masayasu Mie
- Department of Life Science and Technology, Tokyo Institute of Technology, Yokohama, Japan
| | - Mohib Ullah Khondoker
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka, Bangladesh
- Gonoshasthaya Samaj Vittik Medical College, Savar, Dhaka, Bangladesh
| | - Mohd. Raeed Jamiruddin
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka, Bangladesh
- Department of Pharmacy, BRAC University, Dhaka, Bangladesh
| | - Nihad Adnan
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka, Bangladesh
- Department of Microbiology, Jahangirnagar University, Savar, Dhaka, Bangladesh
| |
Collapse
|
11
|
Young S, Taylor SN, Cammarata CL, Varnado KG, Roger-Dalbert C, Montano A, Griego-Fullbright C, Burgard C, Fernandez C, Eckert K, Andrews JC, Ren H, Allen J, Ackerman R, Cooper CK. Clinical Evaluation of BD Veritor SARS-CoV-2 Point-of-Care Test Performance Compared to PCR-Based Testing and versus the Sofia 2 SARS Antigen Point-of-Care Test. J Clin Microbiol 2020; 59:e02338-20. [PMID: 33023911 PMCID: PMC7771450 DOI: 10.1128/jcm.02338-20] [Citation(s) in RCA: 93] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 10/01/2020] [Indexed: 12/23/2022] Open
Abstract
The clinical performance of the BD Veritor System for Rapid Detection of SARS-CoV-2 nucleocapsid antigen (Veritor), a chromatographic immunoassay used for SARS-CoV-2 point-of-care testing, was evaluated using nasal specimens from individuals with COVID-19 symptoms. Two studies were completed to determine clinical performance. In the first study, nasal specimens and either nasopharyngeal or oropharyngeal specimens from 251 participants with COVID-19 symptoms (≤7 days from symptom onset [DSO], ≥18 years of age) were utilized to compare Veritor with the Lyra SARS-CoV-2 PCR assay (Lyra). In the second study, nasal specimens from 361 participants with COVID-19 symptoms (≤5 DSO, ≥18 years of age) were utilized to compare performance of Veritor to that of the Sofia 2 SARS Antigen FIA test (Sofia 2). The positive, negative, and overall percent agreement (PPA, NPA, and OPA, respectively) were the primary outcomes. In study 1, the PPA for Veritor, compared to Lyra, ranged from 81.8 to 87.5% across the 0 to 1 and 0 to 6 DSO ranges. In study 2, Veritor had PPA, NPA, and OPA values of 97.4, 98.1, and 98.1%, respectively, with Sofia 2. Discordant analysis showed one Lyra positive missed by Veritor and five Lyra positives missed by Sofia 2; one Veritor positive result was negative by Lyra. Veritor met FDA emergency use authorization (EUA) acceptance criteria for SARS-CoV-2 antigen testing for the 0 to 5 and 0 to 6 DSO ranges (PPA values of 83.9% and 82.4%, respectively). Veritor and Sofia 2 showed a high degree of agreement for SARS-CoV-2 detection. The Veritor test allows for more rapid COVID-19 testing utilizing easy-to-collect nasal swabs but demonstrated <100% PPA compared to PCR.
Collapse
Affiliation(s)
- Stephen Young
- Tricore Reference Laboratory, Albuquerque, New Mexico, USA
| | - Stephanie N Taylor
- Louisiana State University Health Sciences Center, New Orleans, Louisiana, USA
| | | | - Katey G Varnado
- Louisiana State University Health Sciences Center, New Orleans, Louisiana, USA
| | - Celine Roger-Dalbert
- Becton, Dickinson and Company, BD Life Sciences-Integrated Diagnostic Solutions, Sparks, Maryland, USA
| | - Amanda Montano
- Tricore Reference Laboratory, Albuquerque, New Mexico, USA
| | | | | | - Catherine Fernandez
- Becton, Dickinson and Company, BD Life Sciences-Integrated Diagnostic Solutions, San Diego, California, USA
| | - Karen Eckert
- Becton, Dickinson and Company, BD Life Sciences-Integrated Diagnostic Solutions, Sparks, Maryland, USA
| | - Jeffrey C Andrews
- Becton, Dickinson and Company, BD Life Sciences-Integrated Diagnostic Solutions, Sparks, Maryland, USA
| | - Huimiao Ren
- Becton, Dickinson and Company, BD Life Sciences-Integrated Diagnostic Solutions, San Diego, California, USA
| | | | - Ronald Ackerman
- Comprehensive Clinical Research, LLC, West Palm Beach, Florida, USA
| | - Charles K Cooper
- Becton, Dickinson and Company, BD Life Sciences-Integrated Diagnostic Solutions, Sparks, Maryland, USA
| |
Collapse
|