Machine Perfusion Deters Ischemia-Related Derangement of a Rodent Free Flap: Development of a Model. J Surg Res 2024; 295:203-213. [PMID: 38035871 DOI: 10.1016/j.jss.2023.10.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 09/12/2023] [Accepted: 10/27/2023] [Indexed: 12/02/2023]
Abstract
INTRODUCTION Machine perfusion can enable isolated support of composite tissues, such as free flaps. The goal of perfusion in this setting is to preserve tissues prior to transplantation or provide transient support at the wound bed. This study aimed to establish a rodent model of machine perfusion in a fasciocutaneous-free flap to serve as an affordable testbed and determine the potential of the developed support protocol to deter ischemia-related metabolic derangement. METHODS Rat epigastric-free flaps were harvested and transferred to a closed circuit that provides circulatory and respiratory support. Whole rat blood was recirculated for 8 h, while adjusting the flow rate to maintain arterial-like perfusion pressures. Blood samples were collected during support. Extracellular tissue lactate and glucose levels were characterized with a microdialysis probe and compared with warm ischemic, cold ischemic, and anastomosed-free flap controls. RESULTS Maintenance of physiologic arterial pressures (85-100 mmHg) resulted in average pump flow rates of 360-430 μL/min. Blood-based measurements showed maintained glucose and oxygen consumption throughout machine perfusion. Average normalized lactate to glucose ratio for the perfused flaps was 5-32-fold lower than that for the warm ischemic flap controls during hours 2-8 (P < 0.05). CONCLUSIONS We developed a rat model of ex vivo machine perfusion of a fasciocutaneous-free flap with maintained stable flow and tissue metabolic activity for 8 h. This model can be used to assess critical elements of support in this setting as well as explore other novel therapies and technologies to improve free tissue transfer.
Collapse
|
2
|
Epoxy silane sulfobetaine block copolymers for simple, aqueous thromboresistant coating on ambulatory assist lung devices. J Biomed Mater Res A 2024; 112:99-109. [PMID: 37929658 PMCID: PMC10629844 DOI: 10.1002/jbm.a.37619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 09/08/2023] [Accepted: 09/11/2023] [Indexed: 11/07/2023]
Abstract
Developing an ambulatory assist lung (AAL) for patients who need continuous extracorporeal membrane oxygenation has been associated with several design objectives, including the design of compact components, optimization of gas transfer efficiency, and reduced thrombogenicity. In an effort to address thrombogenicity concerns with currently utilized component biomaterials, a low molecular weight water soluble siloxane-functionalized zwitterionic sulfobetaine (SB-Si) block copolymer was coated on a full-scale AAL device set via a one pot aqueous circulation coating. All device parts including hollow fiber bundle, housing, tubing and cannular were successfully coated with increasing atomic compositions of the SB block copolymer and the coated surfaces showed a significant reduction of platelet deposition while gas exchange performance was sustained. However, water solubility of the SB-Si was unstable, and the coating method, including oxygen plasma pretreatment on the surfaces were considered inconsistent with the objective of developing a simple aqueous coating. Addressing these weaknesses, SB block copolymers were synthesized bearing epoxy or epoxy-silane groups with improved water solubility (SB-EP & SB-EP-Si) and no requirement for surface pretreatment (SB-EP-Si). An SB-EP-Si triblock copolymer showed the most robust coating capacity and stability without prior pretreatment to represent a simple aqueous circulation coating on an assembled full-scale AAL device.
Collapse
|
3
|
Subject-specific factors affecting particle residence time distribution of left atrial appendage in atrial fibrillation: A computational model-based study. Front Cardiovasc Med 2023; 10:1070498. [PMID: 36993996 PMCID: PMC10040531 DOI: 10.3389/fcvm.2023.1070498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 02/20/2023] [Indexed: 03/15/2023] Open
Abstract
BackgroundAtrial fibrillation (AF) is a prevalent arrhythmia, that causes thrombus formation, ordinarily in the left atrial appendage (LAA). The conventional metric of stroke risk stratification, CHA2DS2-VASc score, does not account for LAA morphology or hemodynamics. We showed in our previous study that residence time distribution (RTD) of blood-borne particles in the LAA and its associated calculated variables (i.e., mean residence time, tm, and asymptotic concentration, C∞) have the potential to improve CHA2DS2-VASc score. The purpose of this research was to investigate the effects of the following potential confounding factors on LAA tm and C∞: (1) pulmonary vein flow waveform pulsatility, (2) non-Newtonian blood rheology and hematocrit level, and (3) length of the simulation.MethodsSubject-Specific data including left atrial (LA) and LAA cardiac computed tomography, cardiac output (CO), heart rate, and hematocrit level were gathered from 25 AF subjects. We calculated LAA tm and C∞ based on series of computational fluid dynamics (CFD) analyses.ResultsBoth LAA tm and C∞ are significantly affected by the CO, but not by temporal pattern of the inlet flow. Both LAA tm and C∞ increase with increasing hematocrit level and both calculated indices are higher for non-Newtonian blood rheology for a given hematocrit level. Further, at least 20,000 s of CFD simulation is needed to calculate LAA tm and C∞ values reliably.ConclusionsSubject-specific LA and LAA geometries, CO, and hematocrit level are essential to quantify the subject-specific proclivity of blood cell tarrying inside LAA in terms of the RTD function.
Collapse
|
4
|
Design and In Vitro Evaluation of an Artificial Placenta Made From Hollow Fiber Membranes. ASAIO J 2023; 69:e86-e92. [PMID: 36716073 PMCID: PMC9897463 DOI: 10.1097/mat.0000000000001862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
For infants born at the border of viability, care practices and morbimortality rates vary widely between centers. Trends show significant improvement, however, with increasing gestational age and weight. For periviable infants, the goal of critical care is to bridge patients to improved outcomes. Current practice involves ventilator therapy, resulting in chronic lung injuries. Research has turned to artificial uterine environments, where infants are submerged in an artificial amniotic fluid bath and provided respiratory assistance via an artificial placenta. We have developed the Preemie-Ox, a hollow fiber membrane bundle that provides pumpless respiratory support via umbilical cord cannulation. Computational fluid dynamics was used to design an oxygenator that could achieve a carbon dioxide removal rate of 12.2 ml/min, an outlet hemoglobin saturation of 100%, and a resistance of less than 71 mmHg/L/min at a blood flow rate of 165 ml/min. A prototype was utilized to evaluate in-vitro gas exchange, resistance, and plasma-free hemoglobin generation. In-vitro gas exchange was 4% higher than predicted results and no quantifiable plasma-free hemoglobin was produced.
Collapse
|
5
|
Abstract
BACKGROUND A wearable artificial lung could improve lung transplantation outcomes by easing implementation of physical rehabilitation during long-term pretransplant respiratory support. The Modular Extracorporeal Lung Assist System (ModELAS) is a compact pumping artificial lung currently under development. This study evaluated the long-term in vivo performance of the ModELAS during venovenous support in awake sheep. Feedback from early trials and computational fluid dynamic analysis guided device design optimization along the way. METHODS The ModELAS was connected to healthy sheep via a dual-lumen cannula in the jugular vein. Sheep were housed in a fixed-tether pen while wearing the device in a holster during support. Targeted blood flow rate and support duration were 2-2.5 L/min and 28-30 days, respectively. Anticoagulation was maintained via systemic heparin. Device pumping and gas exchange performance and hematologic indicators of sheep physiology were measured throughout support. RESULTS Computational fluid dynamic-guided design modifications successfully decreased pump thrombogenicity from initial designs. For the optimized design, 4 of 5 trials advancing past early perioperative and cannula-related complications lasted the full month of support. Blood flow rate and CO2 removal in these trials were 2.1 ± 0.3 L/min and 139 ± 15 mL/min, respectively, and were stable during support. One trial ended after 22 days of support due to intradevice thrombosis. Support was well tolerated by the sheep with no signs of hemolysis or device-related organ impairment. CONCLUSIONS These results demonstrate the ability of the ModELAS to provide safe month-long support without consistent deterioration of pumping or gas exchange capabilities.
Collapse
|
6
|
Abstract
Extracorporeal CO2 removal (ECCO2R) can permit lung protective or noninvasive ventilation strategies in patients with chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). With evidence supporting ECCO2R growing, investigating factors which affect CO2 removal is necessary. Multiple factors are known to affect the CO2 removal rate (vCO2) which can complicate the interpretation of changes in vCO2; however, the effect of hematocrit on the vCO2 of artificial lungs has not been investigated. This in vitro study evaluates the relationship between hematocrit level and vCO2 within an ECCO2R device. In vitro gas transfer was measured in bovine blood in accordance with the ISO 7199 standard. Plasma and saline were used to hemodilute the blood to hematocrits between 33% and 8%. The vCO2 significantly decreased as the blood was hemodiluted with saline and plasma by 42% and 32%, respectively, between a hematocrit of 33% and 8%. The hemodilution method did not significantly affect the vCO2. In conclusion, the hematocrit level significantly affects vCO2 and should be taken into account when interpreting changes in the vCO2 of an ECCO2R device.
Collapse
|
7
|
In vivo testing of the low-flow CO 2 removal application of a compact, platform respiratory device. Intensive Care Med Exp 2020; 8:45. [PMID: 32804310 PMCID: PMC7429452 DOI: 10.1186/s40635-020-00329-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Accepted: 07/16/2020] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Non-invasive and lung-protective ventilation techniques may improve outcomes for patients with an acute exacerbation of chronic obstructive pulmonary disease or moderate acute respiratory distress syndrome by reducing airway pressures. These less invasive techniques can fail due to hypercapnia and require transitioning patients to invasive mechanical ventilation. Extracorporeal CO2 removal devices remove CO2 independent of the lungs thereby controlling the hypercapnia and permitting non-invasive or lung-protective ventilation techniques. We are developing the Modular Extracorporeal Lung Assist System as a platform technology capable of providing three levels of respiratory assist: adult and pediatric full respiratory support and adult low-flow CO2 removal. The objective of this study was to evaluate the in vivo performance of our device to achieve low-flow CO2 removal. METHODS The Modular Extracorporeal Lung Assist System was connected to 6 healthy sheep via a 15.5 Fr dual-lumen catheter placed in the external jugular vein. The animals were recovered and tethered within a pen while supported by the device for 7 days. The pump speed was set to achieve a targeted blood flow of 500 mL/min. The extracorporeal CO2 removal rate was measured daily at a sweep gas independent regime. Hematological parameters were measured pre-operatively and regularly throughout the study. Histopathological samples of the end organs were taken at the end of each study. RESULTS All animals survived the surgery and generally tolerated the device well. One animal required early termination due to a pulmonary embolism. Intra-device thrombus formation occurred in a single animal due to improper anticoagulation. The average CO2 removal rate (normalized to an inlet pCO2 of 45 mmHg) was 75.6 ± 4.7 mL/min and did not significantly change over the course of the study (p > 0.05). No signs of consistent hemolysis or end organ damage were observed. CONCLUSION These in vivo results indicate positive performance of the Modular Extracorporeal Lung Assist System as a low-flow CO2 removal device.
Collapse
|
8
|
Abstract
Background: Extracorporeal carbon dioxide removal may be used to manage hypercapnia, but compared to dialysis, it’s not widely available. A recent in vitro study showed that dialysis with low bicarbonate dialysates removes CO2. Objective: To show that bicarbonate dialysis removes CO2 in an animal model to validate in-vitro findings and quantify the effect on arterial pH. Methods: Male Sprague-Dawley hypercapnic rats were dialyzed with either a conventional dialysate (PrismasolTM) or a bicarbonate-free dialysate (Bicarb0). The effect of dialysis on standard blood gases and electrolytes was measured. Results: Partial pressure of CO2 and bicarbonate concentration in blood decreased significantly after exposure to Bicarb0 compared to PrismasolTM (filter outflow values 12.8 vs 81.1 mmHg; p < 0.01 for CO2 and 3.5 vs 22.0 mmol/L; p < 0.01 for bicarbonate). Total CO2 content of blood was reduced by 459 mL/L during dialysis with Bicarb0 (filter inflow 546 ± 91 vs filter outflow 87 ± 52 mL/L; p < 0.01), but was not significantly reduced with PrismasolTM. Conclusions: Bicarbonate dialysis removes CO2 at rates comparable to existing low-flow ECCO2R.
Collapse
|
9
|
Development of zwitterionic sulfobetaine block copolymer conjugation strategies for reduced platelet deposition in respiratory assist devices. J Biomed Mater Res B Appl Biomater 2018; 106:2681-2692. [PMID: 29424964 PMCID: PMC6085169 DOI: 10.1002/jbm.b.34085] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Revised: 01/04/2018] [Accepted: 01/19/2018] [Indexed: 01/22/2023]
Abstract
Respiratory assist devices, that utilize ∼2 m2 of hollow fiber membranes (HFMs) to achieve desired gas transfer rates, have been limited in their adoption due to such blood biocompatibility limitations. This study reports two techniques for the functionalization and subsequent conjugation of zwitterionic sulfobetaine (SB) block copolymers to polymethylpentene (PMP) HFM surfaces with the intention of reducing thrombus formation in respiratory assist devices. Amine or hydroxyl functionalization of PMP HFMs (PMP-A or PMP-H) was accomplished using plasma-enhanced chemical vapor deposition. The generated functional groups were conjugated to low molecular weight SB block copolymers with N-hydroxysuccinimide ester or siloxane groups (SBNHS or SBNHSi) that were synthesized using reversible addition fragmentation chain transfer polymerization. The modified HFMs (PMP-A-SBNHS or PMP-H-SBNHSi) showed 80-95% reduction in platelet deposition from whole ovine blood, stability under the fluid shear of anticipated operating conditions, and uninhibited gas exchange performance relative to non-modified HFMs (PMP-C). Additionally, the functionalization and SBNHSi conjugation technique was shown to reduce platelet deposition on polycarbonate and poly(vinyl chloride), two other materials commonly found in extracorporeal circuits. The observed thromboresistance and stability of the SB modified surfaces, without degradation of HFM gas transfer performance, indicate that this approach is promising for longer term pre-clinical testing in respiratory assist devices and may ultimately allow for the reduction of anticoagulation levels in patients being supported for extended periods. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2681-2692, 2018.
Collapse
|
10
|
Bench Validation of a Compact Low-Flow CO 2 Removal Device. Intensive Care Med Exp 2018; 6:34. [PMID: 30251223 PMCID: PMC6153260 DOI: 10.1186/s40635-018-0200-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Accepted: 09/07/2018] [Indexed: 01/03/2023] Open
Abstract
Background There is increasing evidence demonstrating the value of partial extracorporeal CO2 removal (ECCO2R) for the treatment of hypercapnia in patients with acute exacerbations of chronic obstructive pulmonary disease and acute respiratory distress syndrome. Mechanical ventilation has traditionally been used to treat hypercapnia in these patients, however, it has been well-established that aggressive ventilator settings can lead to ventilator-induced lung injury. ECCO2R removes CO2 independently of the lungs and has been used to permit lung protective ventilation to prevent ventilator-induced lung injury, prevent intubation, and aid in ventilator weaning. The Low-Flow Pittsburgh Ambulatory Lung (LF-PAL) is a low-flow ECCO2R device that integrates the fiber bundle (0.65 m2) and centrifugal pump into a compact unit to permit patient ambulation. Methods A blood analog was used to evaluate the performance of the pump at various impeller rotation rates. In vitro CO2 removal tested under normocapnic conditions and 6-h hemolysis testing were completed using bovine blood. Computational fluid dynamics and a mass-transfer model were also used to evaluate the performance of the LF-PAL. Results The integrated pump was able to generate flows up to 700 mL/min against the Hemolung 15.5 Fr dual lumen catheter. The maximum vCO2 of 105 mL/min was achieved at a blood flow rate of 700 mL/min. The therapeutic index of hemolysis was 0.080 g/(100 min). The normalized index of hemolysis was 0.158 g/(100 L). Conclusions The LF-PAL met pumping, CO2 removal, and hemolysis design targets and has the potential to enable ambulation while on ECCO2R.
Collapse
|
11
|
Time course of red blood cell intracellular pH recovery following short-circuiting in relation to venous transit times in rainbow trout, Oncorhynchus mykiss. Am J Physiol Regul Integr Comp Physiol 2018; 315:R397-R407. [PMID: 29641235 DOI: 10.1152/ajpregu.00062.2018] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Accumulating evidence is highlighting the importance of a system of enhanced hemoglobin-oxygen (Hb-O2) unloading for cardiovascular O2 transport in teleosts. Adrenergically stimulated sodium-proton exchangers (β-NHE) create H+ gradients across the red blood cell (RBC) membrane that are short-circuited in the presence of plasma-accessible carbonic anhydrase (paCA) at the tissues; the result is a large arterial-venous pH shift that greatly enhances O2 unloading from pH-sensitive Hb. However, RBC intracellular pH (pHi) must recover during venous transit (31-90 s) to enable O2 loading at the gills. The halftimes ( t1/2) and magnitudes of RBC β-adrenergic stimulation, short-circuiting with paCA and recovery of RBC pHi, were assessed in vitro, on rainbow trout whole blood, and using changes in closed-system partial pressure of O2 as a sensitive indicator for changes in RBC pHi. In addition, the recovery rate of RBC pHi was assessed in a continuous-flow apparatus that more closely mimics RBC transit through the circulation. Results indicate that: 1) the t1/2 of β-NHE short-circuiting is likely within the residence time of blood in the capillaries, 2) the t1/2 of RBC pHi recovery is 17 s and within the time of RBC venous transit, and 3) after short-circuiting, RBCs reestablish the initial H+ gradient across the membrane and can potentially undergo repeated cycles of short-circuiting and recovery. Thus, teleosts have evolved a system that greatly enhances O2 unloading from pH-sensitive Hb at the tissues, while protecting O2 loading at the gills; the resulting increase in O2 transport per unit of blood flow may enable the tremendous athletic ability of salmonids.
Collapse
|
12
|
Darcy Permeability of Hollow Fiber Membrane Bundles Made from Membrana Polymethylpentene Fibers Used in Respiratory Assist Devices. ASAIO J 2017; 62:329-31. [PMID: 26809086 DOI: 10.1097/mat.0000000000000348] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Hollow fiber membranes (HFMs) are used in blood oxygenators for cardiopulmonary bypass or in next generation artificial lungs. Flow analyses of these devices is typically done using computational fluid dynamics (CFD) modeling HFM bundles as porous media, using a Darcy permeability coefficient estimated from the Blake-Kozeny (BK) equation to account for viscous drag from fibers. We recently published how well this approach can predict Darcy permeability for fiber bundles made from polypropylene HFMs, showing the prediction can be significantly improved using an experimentally derived correlation between the BK constant (A) and bundle porosity (ε). In this study, we assessed how well our correlation for A worked for predicting the Darcy permeability of fiber bundles made from Membrana polymethylpentene (PMP) HFMs, which are increasingly being used clinically. Swatches in the porosity range of 0.4 to 0.8 were assessed in which sheets of fiber were stacked in parallel, perpendicular, and angled configurations. Our previously published correlation predicted Darcy within ±8%. A new correlation based on current and past measured permeability was determined: A = 497ε - 103; using this correlation measured Darcy permeability was within ±6%. This correlation varied from 8% to -3.5% of our prior correlation over the tested porosity range.
Collapse
|
13
|
An extracorporeal carbon dioxide removal (ECCO 2R) device operating at hemodialysis blood flow rates. Intensive Care Med Exp 2017; 5:41. [PMID: 28875449 PMCID: PMC5585119 DOI: 10.1186/s40635-017-0154-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Accepted: 08/21/2017] [Indexed: 01/21/2023] Open
Abstract
Background Extracorporeal carbon dioxide removal (ECCO2R) systems have gained clinical appeal as supplemental therapy in the treatment of acute and chronic respiratory injuries with low tidal volume or non-invasive ventilation. We have developed an ultra-low-flow ECCO2R device (ULFED) capable of operating at blood flows comparable to renal hemodialysis (250 mL/min). Comparable operating conditions allow use of minimally invasive dialysis cannulation strategies with potential for direct integration to existing dialysis circuitry. Methods A carbon dioxide (CO2) removal device was fabricated with rotating impellers inside an annular hollow fiber membrane bundle to disrupt blood flow patterns and enhance gas exchange. In vitro gas exchange and hemolysis testing was conducted at hemodialysis blood flows (250 mL/min). Results In vitro carbon dioxide removal rates up to 75 mL/min were achieved in blood at normocapnia (pCO2 = 45 mmHg). In vitro hemolysis (including cannula and blood pump) was comparable to a Medtronic Minimax oxygenator control loop using a time-of-therapy normalized index of hemolysis (0.19 ± 0.04 g/100 min versus 0.12 ± 0.01 g/100 min, p = 0.169). Conclusions In vitro performance suggests a new ultra-low-flow extracorporeal CO2 removal device could be utilized for safe and effective CO2 removal at hemodialysis flow rates using simplified and minimally invasive connection strategies.
Collapse
|
14
|
Extracorporeal CO 2 removal by hemodialysis: in vitro model and feasibility. Intensive Care Med Exp 2017; 5:20. [PMID: 28390055 PMCID: PMC5383917 DOI: 10.1186/s40635-017-0132-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Accepted: 03/30/2017] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND Critically ill patients with acute respiratory distress syndrome and acute exacerbations of chronic obstructive pulmonary disease often develop hypercapnia and require mechanical ventilation. Extracorporeal carbon dioxide removal can manage hypercarbia by removing carbon dioxide directly from the bloodstream. Respiratory hemodialysis uses traditional hemodialysis to remove CO2 from the blood, mainly as bicarbonate. In this study, Stewart's approach to acid-base chemistry was used to create a dialysate that would maintain blood pH while removing CO2 as well as determine the blood and dialysate flow rates necessary to remove clinically relevant CO2 volumes. METHODS Bench studies were performed using a scaled down respiratory hemodialyzer in bovine or porcine blood. The scaling factor for the bench top experiments was 22.5. In vitro dialysate flow rates ranged from 2.2 to 24 mL/min (49.5-540 mL/min scaled up) and blood flow rates were set at 11 and 18.7 mL/min (248-421 mL/min scaled up). Blood inlet CO2 concentrations were set at 50 and 100 mmHg. RESULTS Results are reported as scaled up values. The CO2 removal rate was highest at intermittent hemodialysis blood and dialysate flow rates. At an inlet pCO2 of 50 mmHg, the CO2 removal rate increased from 62.6 ± 4.8 to 77.7 ± 3 mL/min when the blood flow rate increased from 248 to 421 mL/min. At an inlet pCO2 of 100 mmHg, the device was able to remove up to 117.8 ± 3.8 mL/min of CO2. None of the test conditions caused the blood pH to decrease, and increases were ≤0.08. CONCLUSIONS When the bench top data is scaled up, the system removes a therapeutic amount of CO2 standard intermittent hemodialysis flow rates. The zero bicarbonate dialysate did not cause acidosis in the post-dialyzer blood. These results demonstrate that, with further development, respiratory hemodialysis can be a minimally invasive extracorporeal carbon dioxide removal treatment option.
Collapse
|
15
|
In vitro and in vivo evaluation of a novel integrated wearable artificial lung. J Heart Lung Transplant 2017; 36:806-811. [PMID: 28359655 DOI: 10.1016/j.healun.2017.02.025] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Revised: 01/19/2017] [Accepted: 02/24/2017] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Conventional extracorporeal membrane oxygenation (ECMO) is cumbersome and is associated with high morbidity and mortality. We are currently developing the Pittsburgh Ambulatory Assist Lung (PAAL), which is designed to allow for ambulation of lung failure patients during bridge to transplant or recovery. In this study, we investigated the in vitro and acute in vivo performance of the PAAL. METHODS The PAAL features a 1.75-inch-diameter, cylindrical, hollow-fiber membrane (HFM) bundle of stacked sheets, with a surface area of 0.65 m2 integrated with a centrifugal pump. The PAAL was tested on the bench for hydrodynamic performance, gas exchange and hemolysis. It was then tested in 40- to 60-kg adult sheep (n = 4) for 6 hours. The animals were cannulated with an Avalon Elite 27Fr dual-lumen catheter (DLC) inserted through the right external jugular into the superior vena cava (SVC), right atrium (RA) and inferior vena cava (IVC). RESULTS The PAAL pumped >250 mm Hg at 3.5 liters/min at a rotation speed of 2,100 rpm. Oxygenation performance met the target of 180 ml/min at 3.5 liters/min of blood flow in vitro, resulting in a gas-exchange efficiency of 278 ml/min/m2. The normalized index of hemolysis (NIH) for the PAAL and cannula was 0.054 g per 100 liters (n = 2) at 3.5 liters/min, as compared with 0.020 g per 100 liters (n = 2) for controls (DLC cannula and a Centrimag pump). Plasma-free hemoglobin (pfHb) was <20 mg/dl for all animals. Blood left the device 100% oxygenated in vivo and oxygenation reached 181 ml/min at 3.8 liters/min. CONCLUSION The PAAL met in vitro and acute in vivo performance targets. Five-day chronic sheep studies are planned for the near future.
Collapse
|
16
|
Abstract
The body responds to endotoxins by triggering the acute inflammatory response system to eliminate the threat posed by gram-negative bacteria (endotoxin) and restore health. However, an uncontrolled inflammatory response can lead to tissue damage, organ failure, and ultimately death; this is clinically known as sepsis. Mathematical models of acute inflammatory disease have the potential to guide treatment decisions in critically ill patients. In this work, an 8-state (8-D) differential equation model of the acute inflammatory response system to endotoxin challenge was developed. Endotoxin challenges at 3 and 12 mg/kg were administered to rats, and dynamic cytokine data for interleukin (IL)-6, tumor necrosis factor (TNF), and IL-10 were obtained and used to calibrate the model. Evaluation of competing model structures was performed by analyzing model predictions at 3, 6, and 12 mg/kg endotoxin challenges with respect to experimental data from rats. Subsequently, a model predictive control (MPC) algorithm was synthesized to control a hemoadsorption (HA) device, a blood purification treatment for acute inflammation. A particle filter (PF) algorithm was implemented to estimate the full state vector of the endotoxemic rat based on time series cytokine measurements. Treatment simulations show that: (i) the apparent primary mechanism of HA efficacy is white blood cell (WBC) capture, with cytokine capture a secondary benefit; and (ii) differential filtering of cytokines and WBC does not provide substantial improvement in treatment outcomes vs. existing HA devices.
Collapse
|
17
|
Letter to the Editor on: “Darcy permeability of hollow fiber bundles used in blood oxygenation devices” [J. Membr. Sci. 382 (2011) 238-242]. J Memb Sci 2015. [DOI: 10.1016/j.memsci.2015.09.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
18
|
A Neutrophil Phenotype Model for Extracorporeal Treatment of Sepsis. PLoS Comput Biol 2015; 11:e1004314. [PMID: 26468651 PMCID: PMC4607502 DOI: 10.1371/journal.pcbi.1004314] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2014] [Accepted: 05/01/2015] [Indexed: 11/18/2022] Open
Abstract
Neutrophils play a central role in eliminating bacterial pathogens, but may also contribute to end-organ damage in sepsis. Interleukin-8 (IL-8), a key modulator of neutrophil function, signals through neutrophil specific surface receptors CXCR-1 and CXCR-2. In this study a mechanistic computational model was used to evaluate and deploy an extracorporeal sepsis treatment which modulates CXCR-1/2 levels. First, a simplified mechanistic computational model of IL-8 mediated activation of CXCR-1/2 receptors was developed, containing 16 ODEs and 43 parameters. Receptor level dynamics and systemic parameters were coupled with multiple neutrophil phenotypes to generate dynamic populations of activated neutrophils which reduce pathogen load, and/or primed neutrophils which cause adverse tissue damage when misdirected. The mathematical model was calibrated using experimental data from baboons administered a two-hour infusion of E coli and followed for a maximum of 28 days. Ensembles of parameters were generated using a Bayesian parallel tempering approach to produce model fits that could recreate experimental outcomes. Stepwise logistic regression identified seven model parameters as key determinants of mortality. Sensitivity analysis showed that parameters controlling the level of killer cell neutrophils affected the overall systemic damage of individuals. To evaluate rescue strategies and provide probabilistic predictions of their impact on mortality, time of onset, duration, and capture efficacy of an extracorporeal device that modulated neutrophil phenotype were explored. Our findings suggest that interventions aiming to modulate phenotypic composition are time sensitive. When introduced between 3–6 hours of infection for a 72 hour duration, the survivor population increased from 31% to 40–80%. Treatment efficacy quickly diminishes if not introduced within 15 hours of infection. Significant harm is possible with treatment durations ranging from 5–24 hours, which may reduce survival to 13%. In severe sepsis, an extracorporeal treatment which modulates CXCR-1/2 levels has therapeutic potential, but also potential for harm. Further development of the computational model will help guide optimal device development and determine which patient populations should be targeted by treatment. Sepsis occurs when a patient develops a whole body immune response due to infection. In this condition, white blood cells called neutrophils circulate in an active state, seeking and eliminating invading bacteria. However, when neutrophils are activated, healthy tissue is inadvertently targeted, leading to organ damage and potentially death. Even though sepsis kills millions worldwide, there are still no specific treatments approved in the United States. This may be due to the complexity and diversity of the body’s immune response, which can be managed well using computational modeling. We have developed a computational model to predict how different levels of neutrophil activation impact survival in an overactive inflammatory conditions. The model was utilized to assess the effectiveness of a simulated experimental sepsis treatment which modulates neutrophil populations and activity. This evaluation determined that treatment timing plays a critical role in therapeutic effectiveness. When utilized properly the treatment drastically improves survival, but there is also risk of causing patient harm when introduced at the wrong time. We intend for this computational model to support and guide further development of sepsis treatments and help translate these preliminary results from bench to bedside.
Collapse
|
19
|
Acidic sweep gas with carbonic anhydrase coated hollow fiber membranes synergistically accelerates CO2 removal from blood. Acta Biomater 2015; 25:143-9. [PMID: 26159104 DOI: 10.1016/j.actbio.2015.07.007] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2015] [Revised: 06/26/2015] [Accepted: 07/05/2015] [Indexed: 11/16/2022]
Abstract
The use of extracorporeal carbon dioxide removal (ECCO2R) is well established as a therapy for patients suffering from acute respiratory failure. Development of next generation low blood flow (<500 mL/min) ECCO2R devices necessitates more efficient gas exchange devices. Since over 90% of blood CO2 is transported as bicarbonate (HCO3(-)), we previously reported development of a carbonic anhydrase (CA) immobilized bioactive hollow fiber membrane (HFM) which significantly accelerates CO2 removal from blood in model gas exchange devices by converting bicarbonate to CO2 directly at the HFM surface. This present study tested the hypothesis that dilute sulfur dioxide (SO2) in oxygen sweep gas could further increase CO2 removal by creating an acidic microenvironment within the diffusional boundary layer adjacent to the HFM surface, facilitating dehydration of bicarbonate to CO2. CA was covalently immobilized onto poly (methyl pentene) (PMP) HFMs through glutaraldehyde activated chitosan spacers, potted in model gas exchange devices (0.0151 m(2)) and tested for CO2 removal rate with oxygen (O2) sweep gas and a 2.2% SO2 in oxygen sweep gas mixture. Using pure O2 sweep gas, CA-PMP increased CO2 removal by 31% (258 mL/min/m(2)) compared to PMP (197 mL/min/m(2)) (P<0.05). Using 2.2% SO2 acidic sweep gas increased PMP CO2 removal by 17% (230 mL/min/m(2)) compared to pure oxygen sweep gas control (P<0.05); device outlet blood pH was 7.38 units. When employing both CA-PMP and 2.2% SO2 sweep gas, CO2 removal increased by 109% (411 mL/min/m(2)) (P<0.05); device outlet blood pH was 7.35 units. Dilute acidic sweep gas increases CO2 removal, and when used in combination with bioactive CA-HFMs has a synergistic effect to more than double CO2 removal while maintaining physiologic pH. Through these technologies the next generation of intravascular and paracorporeal respiratory assist devices can remove more CO2 with smaller blood contacting surface areas. STATEMENT OF SIGNIFICANCE A clinical need exists for more efficient respiratory assist devices which utilize low blood flow rates (<500 mL/min) to regulate blood CO2 in patients suffering from acute lung failure. Literature has demonstrated approaches to chemically increase hollow fiber membrane (HFM) CO2 removal efficiency by shifting equilibrium from bicarbonate to gaseous CO2, through either a bioactive carbonic anhydrase enzyme coating or bulk blood acidification with lactic acid. In this study we demonstrate a novel approach to local blood acidification using an acidified sweep gas in combination with a bioactive coating to more than double CO2 removal efficiency of HFM devices. To our knowledge, this is the first report assessing an acidic sweep gas to increase CO2 removal from blood using HFM devices.
Collapse
|
20
|
Kinetics of CO2 exchange with carbonic anhydrase immobilized on fiber membranes in artificial lungs. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2015; 26:193. [PMID: 26032115 PMCID: PMC5973791 DOI: 10.1007/s10856-015-5525-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Accepted: 05/14/2015] [Indexed: 05/12/2023]
Abstract
Artificial lung devices comprised of hollow fiber membranes (HFMs) coated with the enzyme carbonic anhydrase (CA), accelerate removal of carbon dioxide (CO2) from blood for the treatment of acute respiratory failure. While previous work demonstrated CA coatings increase HFM CO2 removal by 115 % in phosphate buffered saline (PBS), testing in blood revealed a 36 % increase compared to unmodified HFMs. In this work, we sought to characterize the CO2 mass transport processes within these biocatalytic devices which impede CA coating efficacy and develop approaches towards improving bioactive HFM efficiency. Aminated HFMs were sequentially reacted with glutaraldehyde (GA), chitosan, GA and afterwards incubated with a CA solution, covalently linking CA to the surface. Bioactive CA-HFMs were potted in model gas exchange devices (0.0119 m(2)) and tested for esterase activity and CO2 removal under various flow rates with PBS, whole blood, and solutions containing individual blood components (plasma albumin, red blood cells or free carbonic anhydrase). Results demonstrated that increasing the immobilized enzyme activity did not significantly impact CO2 removal rate, as the diffusional resistance from the liquid boundary layer is the primary impediment to CO2 transport by both unmodified and bioactive HFMs under clinically relevant conditions. Furthermore, endogenous CA within red blood cells competes with HFM immobilized CA to increase CO2 removal. Based on our findings, we propose a bicarbonate/CO2 disequilibrium hypothesis to describe performance of CA-modified devices in both buffer and blood. Improvement in CO2 removal rates using CA-modified devices in blood may be realized by maximizing bicarbonate/CO2 disequilibrium at the fiber surface via strategies such as blood acidification and active mixing within the device.
Collapse
|
21
|
Veno-venous extracorporeal CO2 removal for the treatment of severe respiratory acidosis. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2015; 19:176. [PMID: 25927222 PMCID: PMC4403910 DOI: 10.1186/s13054-015-0769-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
22
|
Effects of hemoadsorption with a novel adsorbent on sepsis: in vivo and in vitro study. Blood Purif 2015; 39:239-245. [PMID: 25833160 DOI: 10.1159/000381006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Accepted: 02/17/2015] [Indexed: 01/14/2023]
Abstract
BACKGROUND/AIMS Hemoadsorption may improve outcomes for sepsis by removing circulating cytokines. We tested a new sorbent used for hemoadsorption. METHODS CTR sorbent beads were filled into columns of three sizes: CTR0.5 (0.5 ml), CTR1 (1.0 ml) and CTR2 (2.0 ml) and tested using IL-6 capture in vitro. Next, rats were subjected to cecal ligation and puncture and randomly assigned to hemoadsorption with CTR0.5, CTR1, CTR2 or sham treatment. Plasma biomarkers were measured. RESULTS In vitro, IL-6 removal was accelerated with increasing bead mass. In vivo, TNF, IL-6, IL-10, high mobility group box1, and cystatin C were significantly lower 24 h after CTR2 treatment. Seven-day survival rate was 50, 64, 63, and 73% for the sham, CTR0.5, CTR1, CTR2, respectively. CONCLUSION CTR appeared to have a favorable effect on kidney function despite no immediate effects on cytokine removal. However, CTR2 beads did result in a late decrease of cytokines.
Collapse
|
23
|
Hollow fiber membrane modification with functional zwitterionic macromolecules for improved thromboresistance in artificial lungs. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2015; 31:2463-71. [PMID: 25669307 PMCID: PMC4391648 DOI: 10.1021/la504907m] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Respiratory assist devices seek optimized performance in terms of gas transfer efficiency and thromboresistance to minimize device size and reduce complications associated with inadequate blood biocompatibility. The exchange of gas with blood occurs at the surface of the hollow fiber membranes (HFMs) used in these devices. In this study, three zwitterionic macromolecules were attached to HFM surfaces to putatively improve thromboresistance: (1) carboxyl-functionalized zwitterionic phosphorylcholine (PC) and (2) sulfobetaine (SB) macromolecules (mPC or mSB-COOH) prepared by a simple thiol-ene radical polymerization and (3) a low-molecular weight sulfobetaine (SB)-co-methacrylic acid (MA) block copolymer (SBMAb-COOH) prepared by reversible addition-fragmentation chain transfer (RAFT) polymerization. Each macromolecule type was covalently immobilized on an aminated commercial HFM (Celg-A) by a condensation reaction, and HFM surface composition changes were analyzed by X-ray photoelectron spectroscopy. Thrombotic deposition on the HFMs was investigated after contact with ovine blood in vitro. The removal of CO2 by the HFMs was also evaluated using a model respiratory assistance device. The HFMs conjugated with zwitterionic macromolecules (Celg-mPC, Celg-mSB, and Celg-SBMAb) showed expected increases in phosphorus or sulfur surface content. Celg-mPC and Celg-SBMAb experienced rates of platelet deposition significantly lower than those of unmodified (Celg-A, >95% reduction) and heparin-coated (>88% reduction) control HFMs. Smaller reductions were seen with Celg-mSB. The CO2 removal rate for Celg-SBMAb HFMs remained comparable to that of Celg-A. In contrast, the rate of removal of CO2 for heparin-coated HFMs was significantly reduced. The results demonstrate a promising approach to modifying HFMs using zwitterionic macromolecules for artificial lung devices with improved thromboresistance without degradation of gas transfer.
Collapse
|
24
|
Modulation of chemokine gradients by apheresis redirects leukocyte trafficking to different compartments during sepsis, studies in a rat model. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2014; 18:R141. [PMID: 24992991 PMCID: PMC4227131 DOI: 10.1186/cc13969] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2014] [Accepted: 06/11/2014] [Indexed: 12/15/2022]
Abstract
Introduction Prior work suggests that leukocyte trafficking is determined by local chemokine gradients between the nidus of infection and the plasma. We recently demonstrated that therapeutic apheresis can alter immune mediator concentrations in the plasma, protect against organ injury, and improve survival. Here we aimed to determine whether the removal of chemokines from the plasma by apheresis in experimental peritonitis changes chemokine gradients and subsequently enhances leukocyte localization into the infected compartment, and away from healthy tissues. Methods In total, 76 male adult Sprague–Dawley rats weighing 400 g to 600 g were included in this study. Eighteen hours after inducing sepsis by cecal ligation and puncture, we randomized these rats to apheresis or sham treatment for 4 hours. Cytokines, chemokines, and leukocyte counts from blood, peritoneal cavity, and lung were measured. In a separate experiment, we labeled neutrophils from septic donor animals and injected them into either apheresis or sham-treated animals. All numeric data with normal distributions were compared with one-way analysis of variance, and numeric data not normally distributed were compared with the Mann–Whitney U test. Results Apheresis significantly removed plasma cytokines and chemokines, increased peritoneal fluid-to-blood chemokine (C-X-C motif ligand 1, ligand 2, and C-C motif ligand 2) ratios, and decreased bronchoalveolar lavage fluid-to-blood chemokine ratios, resulting in enhanced leukocyte recruitment into the peritoneal cavity and improved bacterial clearance, but decreased recruitment into the lung. Apheresis also reduced myeloperoxidase activity and histologic injury in the lung, liver, and kidney. These Labeled donor neutrophils exhibited decreased localization in the lung when infused into apheresis-treated animals. Conclusions Our results support the concept of chemokine gradient control of leukocyte trafficking and demonstrate the efficacy of apheresis to target this mechanism and reduce leukocyte infiltration into the lung.
Collapse
|
25
|
Effect of impeller design and spacing on gas exchange in a percutaneous respiratory assist catheter. Artif Organs 2014; 38:1007-17. [PMID: 24749994 DOI: 10.1111/aor.12308] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Providing partial respiratory assistance by removing carbon dioxide (CO2 ) can improve clinical outcomes in patients suffering from acute exacerbations of chronic obstructive pulmonary disease and acute respiratory distress syndrome. An intravenous respiratory assist device with a small (25 Fr) insertion diameter eliminates the complexity and potential complications associated with external blood circuitry and can be inserted by nonspecialized surgeons. The impeller percutaneous respiratory assist catheter (IPRAC) is a highly efficient CO2 removal device for percutaneous insertion to the vena cava via the right jugular or right femoral vein that utilizes an array of impellers rotating within a hollow-fiber membrane bundle to enhance gas exchange. The objective of this study was to evaluate the effects of new impeller designs and impeller spacing on gas exchange in the IPRAC using computational fluid dynamics (CFD) and in vitro deionized water gas exchange testing. A CFD gas exchange and flow model was developed to guide a progressive impeller design process. Six impeller blade geometries were designed and tested in vitro in an IPRAC device with 2- or 10-mm axial spacing and varying numbers of blades (2-5). The maximum CO2 removal efficiency (exchange per unit surface area) achieved was 573 ± 8 mL/min/m(2) (40.1 mL/min absolute). The gas exchange rate was found to be largely independent of blade design and number of blades for the impellers tested but increased significantly (5-10%) with reduced axial spacing allowing for additional shaft impellers (23 vs. 14). CFD gas exchange predictions were within 2-13% of experimental values and accurately predicted the relative improvement with impellers at 2- versus 10-mm axial spacing. The ability of CFD simulation to accurately forecast the effects of influential design parameters suggests it can be used to identify impeller traits that profoundly affect facilitated gas exchange.
Collapse
|
26
|
Abstract
For patients experiencing acute respiratory failure due to a severe exacerbation of chronic obstructive pulmonary disease (COPD), noninvasive positive pressure ventilation has been shown to significantly reduce mortality and hospital length of stay compared to respiratory support with invasive mechanical ventilation. Despite continued improvements in the administration of noninvasive ventilation (NIV), refractory hypercapnia and hypercapnic acidosis continue to prevent its successful use in many patients. Recent advances in extracorporeal gas exchange technology have led to the development of systems designed to be safer and simpler by focusing on the clinical benefits of partial extracorporeal carbon dioxide removal (ECCO2R), as opposed to full cardiopulmonary support. While the use of ECCO2R has been studied in the treatment of acute respiratory distress syndrome (ARDS), its use for acute hypercapnic respiratory during COPD exacerbations has not been evaluated until recently. This review will focus on literature published over the last year on the use of ECCO2R for removing extra CO2 in patients experiencing an acute exacerbation of COPD.
Collapse
|
27
|
Leukocyte capture and modulation of cell-mediated immunity during human sepsis: an ex vivo study. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2013; 17:R59. [PMID: 23531333 PMCID: PMC3672497 DOI: 10.1186/cc12587] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2012] [Accepted: 03/18/2013] [Indexed: 01/06/2023]
|
28
|
Hemoadsorption reprograms inflammation in experimental gram-negative septic peritonitis: insights from in vivo and in silico studies. Mol Med 2012; 18:1366-74. [PMID: 22751621 DOI: 10.2119/molmed.2012.00106] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2012] [Accepted: 06/21/2012] [Indexed: 12/22/2022] Open
Abstract
UNLABELLED Improper compartmentalization of the inflammatory response leads to systemic inflammation in sepsis. Hemoadsorption (HA) is an emerging approach to modulate sepsis-induced inflammation. We sought to define the effects of HA on inflammatory compartmentalization in Escherichia coli-induced fibrin peritonitis in rats. HYPOTHESIS HA both reprograms and recompartmentalizes inflammation in sepsis. Sprague Dawley male rats were subjected to E. coli peritonitis and, after 24 h, were randomized to HA or sham treatment (sepsis alone). Venous blood samples collected at 0, 1, 3 and 6 h (that is, 24-30 h of total experimental sepsis), and peritoneal samples collected at 0 and 6 h, were assayed for 14 cytokines along with NO(2)(-/)NO(3)(-). Bacterial counts were assessed in the peritoneal fluid at 0 and 6 h. Plasma tumor necrosis factor (TNF)-α, interleukin (IL)-6, CXCL-1, and CCL2 were significantly reduced in HA versus sham. Principal component analysis (PCA) suggested that inflammation in sham was driven by IL-6 and TNF-α, whereas HA-associated inflammation was driven primarily by TNF-α, CXCL-1, IL-10 and CCL2. Whereas -peritoneal bacterial counts, plasma aspartate transaminase levels and peritoneal IL-5, IL-6, IL-18, interferon (IFN)-γ and NO(2)(-)/NO(3)(-) were significantly lower, both CXCL-1 and CCL2 as well as the peritoneal-to-plasma ratios of TNF-α, CXCL-1 and CCL2 were significantly higher in HA versus sham, suggesting that HA-induced inflammatory recompartmentalization leads to the different inflammatory drivers discerned in part by PCA. In conclusion, this study demonstrates the utility of combined in vivo/in silico methods and suggests that HA exerts differential effects on mediator gradients between local and systemic compartments that ultimately benefit the host.
Collapse
|
29
|
Bench to bedside review: Extracorporeal carbon dioxide removal, past present and future. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2012; 16:232. [PMID: 23014710 PMCID: PMC3682237 DOI: 10.1186/cc11356] [Citation(s) in RCA: 88] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Acute respiratory distress syndrome (ARDS) has a substantial mortality rate and annually affects more than 140,000 people in the USA alone. Standard management includes lung protective ventilation but this impairs carbon dioxide clearance and may lead to right heart dysfunction or increased intracranial pressure. Extracorporeal carbon dioxide removal has the potential to optimize lung protective ventilation by uncoupling oxygenation and carbon dioxide clearance. The aim of this article is to review the carbon dioxide removal strategies that are likely to be widely available in the near future. Relevant published literature was identified using PubMed and Medline searches. Queries were performed by using the search terms ECCOR, AVCO2R, VVCO2R, respiratory dialysis, and by combining carbon dioxide removal and ARDS. The only search limitation imposed was English language. Additional articles were identified from reference lists in the studies that were reviewed. Several novel strategies to achieve carbon dioxide removal were identified, some of which are already commercially available whereas others are in advanced stages of development.
Collapse
|
30
|
Selective capture of anti-A antibodies from human blood using a novel integrated bead and hollow fiber module. J Biomed Mater Res B Appl Biomater 2012; 100:2114-21. [PMID: 22987735 DOI: 10.1002/jbm.b.32776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2011] [Revised: 02/13/2012] [Accepted: 06/28/2012] [Indexed: 11/06/2022]
Abstract
Anti-A/B antibody removal from blood in the peritransplantation period facilitates ABO-incompatible transplantation and significantly increases the donor pool. We have been developing an anti-A/B immunoadsorption device (BSAF), compatible with whole blood perfusion. The BSAF is based on integrated microfiltration hollow fibers with antibody capturing beads uniformly distributed within the fiber interstitial space. In this study we fabricated BSAF prototypes, appropriately scaled down from a conceptual clinical scale device. We then, for the first time, measured the time course of anti-A capture from blood samples recirculating through the scaled down BSAF devices. We observed a significant reduction in IgM (96% ± 5%, n = 5, p < 0.001), and IgG (81% ± 18%, n = 5, p < 0.05) anti-A antibody titers within 2 h. We did not observe a significant change between the initial and final values of hematocrit, total plasma protein concentration, plasma free hemoglobin concentration, and anti-B antibody titer over five experiments. In conclusion we showed that the BSAF modules selectively removed anti-A antibodies from blood in a simple one step process, without requiring a separate plasmapheresis unit.
Collapse
|
31
|
Respiratory dialysis with an active-mixing extracorporeal carbon dioxide removal system in a chronic sheep study. Intensive Care Med 2012; 38:1705-11. [PMID: 22926651 PMCID: PMC3447138 DOI: 10.1007/s00134-012-2651-8] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2012] [Accepted: 07/05/2012] [Indexed: 12/12/2022]
Abstract
PURPOSE The objective of this study was to demonstrate the safety and performance of a unique extracorporeal carbon dioxide removal system (Hemolung, ALung Technologies, Pittsburgh, PA) which incorporates active mixing to improve gas exchange efficiency, reduce exposure of blood to the circuit, and provide partial respiratory support at dialysis-like settings. METHODS An animal study was conducted using eight domestic crossbred sheep, 6-18 months of age and 49-115 kg in weight. The sheep were sedated and intubated, and a 15.5-Fr dual lumen catheter was inserted into the right jugular vein. The catheter was connected to the extracorporeal circuit primed with heparinized saline, and flow immediately initiated. The animals were then awakened and encouraged to stand. The animals were supported in a stanchion and monitored around the clock. Anticoagulation was maintained with heparin to achieve an aPTT of 46-70 s. RESULTS Measurements included blood flow rate through the device, carbon dioxide exchange rate, pump speed and sweep gas flow rate. Safety and biocompatibility measurements included but were not limited to plasma-free hemoglobin, hematocrit, white blood cell count, platelet count and fibrinogen. The Hemolung removed clinically significant amounts of carbon dioxide, more than 50 ml/min, at low blood flows of 350-450 ml/min, with minimal adverse effects. CONCLUSIONS The results of 8-day trials in awake and standing sheep supported by the Hemolung demonstrated that this device can consistently achieve clinically relevant levels of carbon dioxide removal without failure and without significant risk of adverse reactions.
Collapse
|
32
|
Immobilized Carbonic Anhydrase on Hollow Fiber Membranes Accelerates CO(2) Removal from Blood. J Memb Sci 2012; 404-404:25-31. [PMID: 22962517 DOI: 10.1016/j.memsci.2012.02.006] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Current artificial lungs and respiratory assist devices designed for carbon dioxide removal (CO(2)R) are limited in their efficiency due to the relatively small partial pressure difference across gas exchange membranes. To offset this underlying diffusional challenge, bioactive hollow fiber membranes (HFMs) increase the carbon dioxide diffusional gradient through the immobilized enzyme carbonic anhydrase (CA), which converts bicarbonate to CO(2) directly at the HFM surface. In this study, we tested the impact of CA-immobilization on HFM CO(2) removal efficiency and thromboresistance in blood. Fiber surface modification with radio frequency glow discharge (RFGD) introduced hydroxyl groups, which were activated by 1M CNBr while 1.5M TEA was added drop wise over the activation time course, then incubation with a CA solution covalently linked the enzyme to the surface. The bioactive HFMs were then potted in a model gas exchange device (0.0084 m(2)) and tested in a recirculation loop with a CO(2) inlet of 50mmHg under steady blood flow. Using an esterase activity assay, CNBr chemistry with TEA resulted in 0.99U of enzyme activity, a 3.3 fold increase in immobilized CA activity compared to our previous method. These bioactive HFMs demonstrated 108 ml/min/m(2) CO(2) removal rate, marking a 36% increase compared to unmodified HFMs (p < 0.001). Thromboresistance of CA-modified HFMs was assessed in terms of adherent platelets on surfaces by using lactate dehydrogenase (LDH) assay as well as scanning electron microscopy (SEM) analysis. Results indicated HFMs with CA modification had 95% less platelet deposition compared to unmodified HFM (p < 0.01). Overall these findings revealed increased CO(2) removal can be realized through bioactive HFMs, enabling a next generation of more efficient CO(2) removal intravascular and paracorporeal respiratory assist devices.
Collapse
|
33
|
Modeling competitive cytokine adsorption dynamics within hemoadsorption beads used to treat sepsis. J Chromatogr A 2011; 1218:8013-20. [PMID: 21962329 DOI: 10.1016/j.chroma.2011.09.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2011] [Revised: 08/07/2011] [Accepted: 09/05/2011] [Indexed: 10/17/2022]
Abstract
Extracorporeal blood purification is a promising therapeutic modality for sepsis, a potentially fatal, dysfunctional immunologic state caused by infection. Removal of inflammatory mediators such as cytokines from the blood may help attenuate hyper-inflammatory signaling during sepsis and improve patient outcomes. We are developing a hemoadsorption device to remove cytokines from the circulating blood using biocompatible, porous sorbent beads. In this work, we investigated whether competitive adsorption of serum solutes affects cytokine removal dynamics within the hemoadsorption beads. Confocal laser scanning microscopy (CLSM) was used to quantify intraparticle adsorption profiles of fluorescently labeled IL-6 in horse serum, and results were compared to predictions of a two component competitive adsorption model. Supraphysiologic IL-6 concentrations were necessary to obtain adequate CLSM signal, therefore unknown model parameters were fit to CLSM data at high IL-6 concentrations, and the fitted model was used to simulate cytokine adsorption behavior at physiologically relevant levels which were below the microscopy detection threshold. CLSM intraparticle IL-6 adsorption profiles agreed with predictions of the competitive adsorption model, indicating displacement of cytokine by high affinity serum solutes. However, competitive adsorption effects were predicted using the model to be negligible at physiologic cytokine concentrations associated with hemoadsorption therapy.
Collapse
|
34
|
Abstract
Many industrial and biomedical devices (e.g. blood oxygenators and artificial lungs) use bundles of hollow fiber membranes for separation processes. Analyses of flow and mass transport within the shell-side of the fiber bundles most often model the bundle for simplicity as a packed bed or porous media, using a Darcy permeability coefficient estimated from the Blake-Kozeny equation to account for viscous drag from the fibers. In this study, we developed a simple method for measuring the Darcy permeability of hollow fiber membrane bundles and evaluated how well the Blake-Kozeny (BK) equation predicted the Darcy permeability for these bundles. Fiber bundles were fabricated from commercially available Celgard® ×30-240 fiber fabric (300 μm outer diameter fibers @ 35 and 54 fibers/inch) and from a fiber fabric with 193 μm fibers (61 fibers/inch). The fiber bundles were mounted to the bottom of an acrylic tube and Darcy permeability was determined by measuring the elapsed time for a column of glycerol solution to flow through a fiber bundle. The ratio of the measured Darcy permeability to that predicted from the BK equation varied from 1.09 to 0.56. A comprehensive literature review suggested a modified BK equation with the "constant" correlated to porosity. This modification improved the predictions of the BK equation, with the ratio of measured to predicted permeability varying from 1.13 to 0.84.
Collapse
|
35
|
Acute removal of common sepsis mediators does not explain the effects of extracorporeal blood purification in experimental sepsis. Kidney Int 2011; 81:363-9. [PMID: 21918497 DOI: 10.1038/ki.2011.320] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The effect of extracorporeal blood purification on clinical outcomes in sepsis is assumed to be related to modulation of plasma cytokine concentrations. To test this hypothesis directly, we treated rats that had a cecal ligation followed by puncture (a standard model of sepsis) with a modest dose of extracorporeal blood purification that did not result in acute changes in a panel of common cytokines associated with inflammation (TNF-α, IL-1β, IL-6, and IL-10). Pre- and immediate post-treatment levels of these cytokines were unchanged compared to the sham therapy of extracorporeal circulation without blood purifying sorbent. The overall survival to 7 days, however, was significantly better in animals that received extracorporeal blood purification compared to those with a sham procedure. This panel of common plasma cytokines along with alanine aminotransferase and creatinine was significantly lower 72 h following extracorporeal blood purification compared to sham-treated rats. Thus, the effects of this procedure on organ function and survival do not appear to be due solely to immediate changes in the usual measured circulating cytokines. These results may have important implications for the design and conduct of future trials in sepsis including defining alternative targets for extracorporeal blood purification and other therapies.
Collapse
|
36
|
Characterizing accelerated capture of deoligomerized TNF within hemoadsorption beads used to treat sepsis. J Biomed Mater Res B Appl Biomater 2011; 98:47-53. [DOI: 10.1002/jbm.b.31830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2010] [Revised: 01/17/2011] [Accepted: 02/03/2011] [Indexed: 11/10/2022]
|
37
|
Specific antibody filter (SAF) binding capacity enhancement to remove anti-A antibodies. J Biomed Mater Res B Appl Biomater 2011; 95:475-80. [PMID: 20878917 DOI: 10.1002/jbm.b.31707] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Removal of Anti-A/B antibodies prior to ABO-incompatible transplantation can prevent hyperacute organ rejection. We are developing a specific antibody filter (SAF) device to selectively remove ABO blood group antibodies from the whole blood by utilizing immunoaffinity adsorption. The device consists of ultrafiltration hollow fiber membranes with synthetic antigens specific to bind blood group antibodies immobilized on the inner lumenal walls of the fibers. The aim of this study was to evaluate the effect of antigen molecular weight and surface activation process to increase the antibody binding capacity of the fiber membrane surface. A new higher molecular weight antigen Atri-pNSA-1000 compared with Atri-pNPA-30 (A-trisaccharide (Atri) conjugated to activated polymers of Mol. wt. 1000 kDa and 30 kDa, respectively) was employed to improve accessibility of the antigen to bind antibodies. Also, a cyanogen bromide (CNBr) based surface activation method mediated by TEA in neutral pH medium was used to enhance the number of active sites for antigen binding compared to a strong basic medium of NaOH. Using a CNBr/TEA activation method and by immobilizing Atri-pNSA-1000 antigen, an antibody binding capacity (∼0.01 monoclonal anti-A IgM nmol/cm(2)) was achieved on the fiber surface. This binding capacity was sufficient to reduce monoclonal antibody titer from 1:128 to final titer below 1:4 with a surface area to volume ratio that is similar to commercial dialysis device (∼1.1 m(2) surface area for an average body blood volume of 5 L).
Collapse
|
38
|
Selective improvement of tumor necrosis factor capture in a cytokine hemoadsorption device using immobilized anti-tumor necrosis factor. J Biomed Mater Res B Appl Biomater 2011; 96:127-33. [PMID: 21086427 PMCID: PMC3221482 DOI: 10.1002/jbm.b.31748] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Sepsis is a harmful hyper-inflammatory state characterized by overproduction of cytokines. Removal of these cytokines using an extracorporeal device is a potential therapy for sepsis. We are developing a cytokine adsorption device (CAD) filled with porous polymer beads which efficiently depletes middle-molecular weight cytokines from a circulating solution. However, removal of one of our targeted cytokines, tumor necrosis factor (TNF), has been significantly lower than other smaller cytokines. We addressed this issue by incorporating anti-TNF antibodies on the outer surface of the beads. We demonstrated that covalent immobilization of anti-TNF increases overall TNF capture from 55% (using unmodified beads) to 69%. Passive adsorption increases TNF capture to over 99%. Beads containing adsorbed anti-TNF showed no significant loss in their ability to remove smaller cytokines, as tested using interleukin-6 (IL-6) and interleukin-10 (IL-10). We also detail a novel method for quantifying surface-bound ligand on a solid substrate. This assay enabled us to rapidly test several methods of antibody immobilization and their appropriate controls using dramatically fewer resources. These new adsorbed anti-TNF beads provide an additional level of control over a device which previously was restricted to nonspecific cytokine adsorption. This combined approach will continue to be optimized as more information becomes available about which cytokines play the most important role in sepsis.
Collapse
|
39
|
Hemocompatibility assessment of carbonic anhydrase modified hollow fiber membranes for artificial lungs. Artif Organs 2010; 34:439-42. [PMID: 20633159 DOI: 10.1111/j.1525-1594.2009.00882.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Hollow fiber membrane (HFM)-based artificial lungs can require a large blood-contacting membrane surface area to provide adequate gas exchange. However, such a large surface area presents significant challenges to hemocompatibility. One method to improve carbon dioxide (CO(2)) transfer efficiency might be to immobilize carbonic anhydrase (CA) onto the surface of conventional HFMs. By catalyzing the dehydration of bicarbonate in blood, CA has been shown to facilitate diffusion of CO(2) toward the fiber membranes. This study evaluated the impact of surface modifying a commercially available microporous HFM-based artificial lung on fiber blood biocompatibility. A commercial poly(propylene) Celgard HFM surface was coated with a siloxane, grafted with amine groups, and then attached with CA which has been shown to facilitate diffusion of CO(2) toward the fiber membranes. Results following acute ovine blood contact indicated no significant reduction in platelet deposition or activation with the siloxane coating or the siloxane coating with grafted amines relative to base HFMs. However, HFMs with attached CA showed a significant reduction in both platelet deposition and activation compared with all other fiber types. These findings, along with the improved CO(2) transfer observed in CA modified fibers, suggest that its incorporation into HFM design may potentiate the design of a smaller, more biocompatible HFM-based artificial lung.
Collapse
|
40
|
A biohybrid artificial lung prototype with active mixing of endothelialized microporous hollow fibers. Biotechnol Bioeng 2010; 106:490-500. [PMID: 20091735 DOI: 10.1002/bit.22675] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Acute respiratory distress syndrome (ARDS) affects nearly 150,000 patients per year in the US, and is associated with high mortality ( approximately 40%) and suboptimal options for patient care. Mechanical ventilation and extracorporeal membrane oxygenation are limited to short-term use due to ventilator-induced lung injury and poor biocompatibility, respectively. In this report, we describe the development of a biohybrid lung prototype, employing a rotating endothelialized microporous hollow fiber (MHF) bundle to improve blood biocompatibility while MHF mixing could contribute to gas transfer efficiency. MHFs were surface modified with radio frequency glow discharge (RFGD) and protein adsorption to promote endothelial cell (EC) attachment and growth. The MHF bundles were placed in the biohybrid lung prototype and rotated up to 1,500 revolutions per minute (rpm) using speed ramping protocols to condition ECs to remain adherent on the fibers. Oxygen transfer, thrombotic deposition, and EC p-selectin expression were evaluated as indicators of biohybrid lung functionality and biocompatibility. A fixed aliquot of blood in contact with MHF bundles rotated at either 250 or 750 rpm reached saturating pO(2) levels more quickly with increased rpm, supporting the concept that fiber rotation would positively contribute to oxygen transfer. The presence of ECs had no effect on the rate of oxygen transfer at lower fiber rpm, but did provide some resistance with increased rpm when the overall rate of mass transfer was higher due to active mixing. RFGD followed by fibronectin adsorption on MHFs facilitated near confluent EC coverage with minimal p-selectin expression under both normoxic and hyperoxic conditions. Indeed, even subconfluent EC coverage on MHFs significantly reduced thrombotic deposition adding further support that endothelialization enhances, blood biocompatibility. Overall these findings demonstrate a proof-of-concept that a rotating endothelialized MHF bundle enhances gas transfer and biocompatibility, potentially producing safer, more efficient artificial lungs.
Collapse
|
41
|
IL-6 adsorption dynamics in hemoadsorption beads studied using confocal laser scanning microscopy. J Biomed Mater Res B Appl Biomater 2010; 92:390-6. [PMID: 19904819 DOI: 10.1002/jbm.b.31527] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Sepsis is characterized by a systemic inflammatory response caused by infection, and can result in organ failure and death. Removal of inflammatory mediators such as cytokines from the circulating blood is a promising treatment for severe sepsis. We are developing an extracorporeal hemoadsorption device to remove cytokines from the blood using biocompatible, polymer sorbent beads. In this study, we used confocal laser scanning microscopy (CLSM) to directly examine adsorption dynamics of a cytokine (IL-6) within hemoadsorption beads. Fluorescently labeled IL-6 was incubated with sorbent particles, and CLSM was used to quantify spatial adsorption profiles of IL-6 within the sorbent matrix. IL-6 adsorption was limited to the outer 15 microm of the sorbent particle over a relevant clinical time period, and intraparticle adsorption dynamics was modeled using classical adsorption/diffusion mechanisms. A single model parameter, alpha = q(max) K/D, was estimated by fitting CLSM intensity profiles to our mathematical model, where q(max) and K are Langmuir adsorption isotherm parameters, and D is the effective diffusion coefficient of IL-6 within the sorbent matrix. Given the large diameter of our sorbent beads (450 microm), less than 20% of available sorbent surface area participates in cytokine adsorption. Development of smaller beads may accelerate cytokine adsorption by maximizing available surface area per bead mass.
Collapse
|
42
|
High molecular weight blood group A trisaccharide-polyacrylamide glycoconjugates as synthetic blood group A antigens for anti-A antibody removal devices. J Biomed Mater Res B Appl Biomater 2009; 91:845-854. [PMID: 19582848 PMCID: PMC5944835 DOI: 10.1002/jbm.b.31466] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Specific immunoadsorption of blood group antibodies by synthetic antigens immobilized on support matrices in the peri-transplantation period provides a promising solution to hyperacute rejection risk following ABO-incompatible transplantation. In this study, we investigated binding interactions between anti-A antibodies and synthetic blood group A trisaccharide conjugated with polyacrylamide of different molecular weights (30 and 1000 kDa). The glycopolymers were equipped with biotin tags and deposited on streptavidin-coated sensor chips. The affinity and kinetics of anti-A antibodies binding to glycoconjugates were studied using surface plasmon resonance (SPR). The high molecular weight conjugate (Atri-PAA(1000)-biotin) enhanced antibody binding capacity by two to three fold compared with the low molecular weight conjugate (Atri-PAA(30)-biotin), whereas varying the carbohydrate content in Atri-PAA(1000)-biotin (20 mol % or 50 mol %) did not affect antibody binding capacity of the glycoconjugate. The obtained results suggest that immunoadsorption devices, especially hollow fiber-based antibody filters which are limited in available surface area for antigen immobilization, may greatly benefit from the new synthetic high molecular weight polyacrylamide glycoconjugates.
Collapse
|
43
|
Experimental validation of a theoretical model of cytokine capture using a hemoadsorption device. Ann Biomed Eng 2009; 37:2310-6. [PMID: 19680812 DOI: 10.1007/s10439-009-9780-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2009] [Accepted: 08/05/2009] [Indexed: 12/17/2022]
Abstract
Sepsis, a systemic inflammatory response in the presence of an infection, is characterized by overproduction of inflammatory mediators called cytokines. Removal of these cytokines using an extracorporeal hemoadsorption device is a potential therapy for sepsis. We are developing a cytokine adsorption device (CAD) filled with microporous polymer beads and have previously published a mathematical model which predicts the time course of cytokine removal by the device. The goal of this study was to show that the model can experimentally predict the rate of cytokine capture associated with key design and operational parameters of the CAD. We spiked IL-6, IL-10, and TNF into horse serum and perfused it through an appropriately scaled-down CAD and measured the change in concentration of the cytokines over time. These data were fit to the mathematical model to determine a single model parameter, Gamma( i ), which is only a function of the cytokine-polymer interaction and the cytokine effective diffusion coefficient in the porous matrix. We compared Gamma( i ) values, which by definition should not change between experiments. Our results indicate that the Gamma( i ) value for a specific cytokine was statistically independent of all other parameters in the model, including initial cytokine concentration, flow rate, serum reservoir volume, CAD size, and bead size. Our results also indicate that competitive adsorption of cytokines and other middle-molecular weight proteins, which is neglected in the model, does not affect the rate of removal of a given cytokine. The model of cytokine capture in the CAD developed in this study will be integrated with a systems model of sepsis to simulate the progression of sepsis in humans and to develop a therapeutic CAD design and intervention protocol that improves patient outcomes in sepsis.
Collapse
|
44
|
|
45
|
A unified mathematical model for the prediction of controlled release from surface and bulk eroding polymer matrices. Biomaterials 2008; 30:1657-64. [PMID: 19101031 DOI: 10.1016/j.biomaterials.2008.12.002] [Citation(s) in RCA: 95] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2008] [Accepted: 12/01/2008] [Indexed: 10/21/2022]
Abstract
A unified model has been developed to predict release not only from bulk eroding and surface eroding systems but also from matrices that transition from surface eroding to bulk eroding behavior during the course of degradation. This broad applicability is afforded by fundamental diffusion/reaction equations that can describe a wide variety of scenarios including hydration of and mass loss from a hydrolysable polymer matrix. Together, these equations naturally account for spatial distributions of polymer degradation rate. In this model paradigm, the theoretical minimal size required for a matrix to exhibit degradation under surface eroding conditions was calculated for various polymer types and then verified by empirical data from the literature. An additional set of equations accounts for dissolution- and/or degradation-based release, which are dependent upon hydration of the matrix and erosion of the polymer. To test the model's accuracy, predictions for agent egress were compared to experimental data from polyanhydride and polyorthoester implants that were postulated to undergo either dissolution-limited or degradation-controlled release. Because these predictions are calculated solely from readily attainable design parameters, it seems likely that this model could be used to guide the design controlled release formulations that produce a broad array of custom release profiles.
Collapse
|
46
|
A simple mathematical model of cytokine capture using a hemoadsorption device. Ann Biomed Eng 2008; 37:222-9. [PMID: 18949559 DOI: 10.1007/s10439-008-9587-8] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2008] [Accepted: 10/17/2008] [Indexed: 12/01/2022]
Abstract
Sepsis is a systemic response to infection characterized by increased production of inflammatory mediators including cytokines. Increased production of cytokines such as interleukin-6 (IL-6), interleukin-10 (IL-10), and tumor necrosis factor (TNF) can have deleterious effects. Removal of cytokines via adsorption onto porous polymer substrates using an extracorporeal device may be a potential therapy for sepsis. We are developing a cytokine adsorption device (CAD) containing microporous polymer beads that will be used to decrease circulating levels of IL-6, TNF, and IL-10. In this paper we present a mathematical model of cytokine adsorption within such a device. The model accounts for macroscale transport through the device and internal diffusion and adsorption within the microporous beads. The analysis results in a simple analytic expression for the removal rate of individual cytokines that depends on a single cytokine-polymer specific parameter, Gamma( i ). This model was fit to experimental data and the value of Gamma( i ) was determined via nonlinear regression for IL-6, TNF, and IL-10. The model agreed well with the experimental data on the time course of cytokine removal. The model of the CAD and the values of Gamma( i ) will be applied in mathematical models of the inflammatory process and treatment of patients with sepsis.
Collapse
|
47
|
RESPIRATORY DIALYSIS: A NEW THERAPY FOR CHRONIC OBSTRUCTIVE PULMONARY DISEASE. Chest 2008. [DOI: 10.1378/chest.134.4_meetingabstracts.s30002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
48
|
A novel flex-stretch-flow bioreactor for the study of engineered heart valve tissue mechanobiology. Ann Biomed Eng 2008; 36:700-12. [PMID: 18253834 DOI: 10.1007/s10439-008-9447-6] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2006] [Accepted: 01/22/2008] [Indexed: 11/26/2022]
Abstract
Tissue engineered heart valves (TEHV) have been observed to respond to mechanical conditioning in vitro by expression of activated myofibroblast phenotypes followed by improvements in tissue maturation. In separate studies, cyclic flexure, stretch, and flow (FSF) have been demonstrated to exhibit both independent and coupled stimulatory effects. Synthesis of these observations into a rational framework for TEHV mechanical conditioning has been limited, however, due to the functional complexity of tri-leaflet valves and the inherent differences of separate bioreactor systems. Toward quantifying the effects of individual mechanical stimuli similar to those that occur during normal valve function, a novel bioreactor was developed in which FSF mechanical stimuli can be applied to engineered heart valve tissues independently or in combination. The FSF bioreactor consists of two identically equipped chambers, each having the capacity to hold up to 12 rectangular tissue specimens (25 x 7.5 x 1 mm) via a novel "spiral-bound" technique. Specimens can be subjected to changes-in-curvature up to 50 mm(-1) and uniaxial tensile strains up to 75%. Steady laminar flow can be applied by a magnetically coupled paddlewheel system. Computational fluid dynamic (CFD) simulations were conducted and experimentally validated by particle image velocimetry (PIV). Tissue specimen wall shear stress profiles were predicted as a function of paddlewheel speed, culture medium viscosity, and the quasi-static state of specimen deformation (i.e., either undeformed or completely flexed). Velocity profiles predicted by 2D CFD simulations of the paddlewheel mechanism compared well with PIV measurements, and were used to determine boundary conditions in localized 3D simulations. For undeformed specimens, predicted inter-specimen variations in wall shear stress were on average +/-7%, with an average wall shear stress of 1.145 dyne/cm(2) predicted at a paddlewheel speed of 2000 rpm and standard culture conditions. In contrast, while the average wall shear stress predicted for specimens in the quasi-static flexed state was approximately 59% higher (1.821 dyne/cm(2)), flexed specimens exhibited a broad intra-specimen wall shear stress distribution between the convex and concave sides that correlated with specimen curvature, with peak wall shear stresses of approximately 10 dyne/cm(2). This result suggests that by utilizing simple flexed geometric configurations, the present system can also be used to study the effects of spatially varying shear stresses. We conclude that the present design provides a robust tool for the study of mechanical stimuli on in vitro engineered heart valve tissue formation.
Collapse
|
49
|
Monoclonal anti-A antibody removal by synthetic A antigen immobilized on specific antibody filters. Biotechnol Bioeng 2008; 99:876-83. [PMID: 17705231 DOI: 10.1002/bit.21621] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Removal of blood group anti-A and anti-B antibodies can prevent hyperacute organ rejection in ABO-incompatible transplantation. We are developing an extracorporeal-specific antibody filter (SAF) as an immunoadsorption device for direct removal of ABO blood group antibodies from whole blood, without the need for plasma separation and plasma exchange. A hollow fiber-based small scale SAF (mini-SAF) device was fabricated and synthetic A antigen, Atrisaccharide (Atri) conjugated to activated polyacrylic acid, was immobilized on the fiber lumen surface. Monoclonal antibody anti-A IgM were specifically removed up to 70% of initial antibodies using mini-SAF device. The monoclonal anti-A capture experiments on mini-SAF indicated that antibody removal relative to the initial concentration is independent of inlet concentration in the beginning; however, as the surface starts saturating with bound antibodies, removal becomes dependent on inlet concentration. No significant effect of flow rate on removal rate was observed. The radial diffusion and axial convection-based mathematical model developed for unsteady state antibody removal was in good agreement with the experimental data and showed that the antibody removal rate can be maximized by increasing the antibody-binding capacity of the SAF.
Collapse
|
50
|
A simple model framework for the prediction of controlled release from bulk eroding polymer matrices. ACTA ACUST UNITED AC 2008. [DOI: 10.1039/b718277e] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|