1
|
Electrically conductive synthetic vocal fold replicas for voice production research. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 142:EL63. [PMID: 28764459 PMCID: PMC5724742 DOI: 10.1121/1.4990540] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Accepted: 06/15/2017] [Indexed: 06/01/2023]
Abstract
A method of fabricating electrically conductive synthetic vocal fold replicas and monitoring their vibration via resistance measurement is presented. Normally non-conductive silicone replicas were coated with conductive graphite and subjected to long-term vibration tests. Synchronized resistance and imaging data using hemilarynx and full larynx configurations showed an inverse correlation between replica contact area and resistance during vibration, similar to clinical electroglottography (EGG) used to estimate vocal fold contact area. This method has potential for long-term replica vibration monitoring and studying basic physical relationships between resistance and contact area in vocal folds and vocal fold replicas.
Collapse
|
2
|
Evaluation of Bond Strength, Marginal Integrity, and Fracture Strength of Bulk- vs Incrementally-filled Restorations. THE JOURNAL OF ADHESIVE DENTISTRY 2017; 18:317-23. [PMID: 27419244 DOI: 10.3290/j.jad.a36516] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This study evaluated the effect of application technique and preparation size on the fracture strength (FS), microtensile bond strength (μTBS) and marginal integrity (MI) of direct resin composite restorations. MATERIALS AND METHODS Conservative (5 × 2 × 2 mm) or extended (5 × 4 × 2 mm) preparations below the cementoenamel junction were performed in 140 human maxillary premolars (n = 70 per group). After adhesive application (XP Bond), half of each group was restored with the bulk technique (one 4-mm increment of Surefill SDR Flow plus one 1-mm horizontal capping layer of TPH3 [Spectrum TPH3 resin composite]) and half incrementally (TPH3 in three horizontal incremental layers, 1.5 to 2 mm each), all using a metal matrix band. After storage (24 h at 37°C), the proximal surfaces of each tooth were polished with Sof-Lex disks. For FS measurement, 60 restorations were mounted in a universal testing machine and subjected to a compressive axial load applied parallel to the long axis of the tooth, running at a crosshead speed of 0.5 mm/min. For μTBS testing, 40 teeth were longitudinally sectioned to obtain resin-dentin bonded sticks from the cavity floor (bonded area: 0.8 mm2). Specimens were tested in tension at 0.5 mm/min. The external marginal integrity of both proximal surfaces was analyzed using SEM of epoxy resin replicas. The μTBS, marginal integrity, and fracture resistance data were subjected to two-way ANOVA, and Tukey's post-hoc test was used for pair-wise comparisons (a = 0.05). RESULTS Fracture resistance, microtensile bond strength, and marginal integrity values were not statistically significantly affected by application technique or preparation size (p = 0.71, p = 0.82, and p = 0.77, respectively). CONCLUSIONS The use of a bulk-fill flowable composite associated with a conventional resin composite as a final capping layer did not jeopardize the fracture strength, bond strength to dentin, or marginal integrity of posterior restorations.
Collapse
|
3
|
Abstract
Wear phenomena of ceramic inlays are not fully understood. The aim of the present study was to evaluate ceramic wear, antagonist enamel wear, and luting cement wear over 8 years. The two-fold null hypothesis was that there would be (1) no difference in wear behavior between ceramic and enamel, and (2) no influence of filler content of luting composites on composite wear. From 96 restorations, 36 Class II inlays from 16 participants were selected. For inlays with opposing enamel cusps (n = 17), replicas of inlays and enamel were scanned with a 3-D laser scanner. Luting gaps of inlays (n = 36) were analyzed with a profilometer, including 3-D data analysis. Ceramic and enamel wear increased between 4 and 8 years, with significantly higher values for enamel after 6 years (p < 0.05). Luting gap wear increased continuously up to 8 years (p < 0.05), with no influence of luting composites (p > 0.05) and location of teeth (p > 0.05).
Collapse
|
4
|
Abstract
Adhesive dentistry should effectively restore the peripheral seal of dentin after enamel removal. We hypothesize that non-rinsing, simplified, one-step self-etch adhesives are effective for minimizing dentin permeability after tooth preparation procedures. Crown preparations in vital human teeth were sealed with Adper Prompt, Xeno III, iBond, or One-Up Bond F. Epoxy resin replicas were produced from polyvinyl siloxane impressions for SEM examination. Dentin surfaces from extracted human teeth were bonded with these adhesives and connected to a fluid-transport model for permeability measurements and TEM examination. Dentinal fluid droplets were observed from adhesive surfaces in resin replicas of in vivo specimens. In vitro fluid conductance of dentin bonded with one-step self-etch adhesives was either similar to or greater than that of smear-layer-covered dentin. TEM revealed water trees within the adhesives that facilitate water movement across the polymerized, highly permeable adhesives. Both in vitro and in vivo results did not support the proposed hypothesis.
Collapse
|
5
|
Abstract
Fluid transudation through simplified dentin adhesives can occur in bonded vital crown dentin, since these adhesives behave as permeable membranes after polymerization. The effect of adhesive permeability in endodontically treated teeth is unknown. This study examined the hypothesis that in vivo fluid movement through simplified adhesives occurs when they are applied to root canals. Dowel spaces were prepared in endodontically treated teeth with single root canals. Six adhesives were applied to the intra-radicular dentin of canal walls. Impressions were obtained with polyvinyl siloxane, and replicas were fabricated with the use of polyether impression material. Replica hemisections were gold-coated for SEM examination. Fluid transudation was evident on the adhesive surfaces of all simplified total-etch and self-etch adhesives. Conversely, most of the specimens bonded with the control three-step total-etch adhesive were devoid of fluid droplets. Permeability of simplified adhesives results in water movement, even in root-treated dentin. This may adversely affect the coupling of auto-/dual-cured resin cements.
Collapse
|
6
|
Quantification of velocity reduction after flow diverter placement in intracranial aneurysm: An ex vivo study with 3D printed replicas. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:7300-3. [PMID: 26737977 DOI: 10.1109/embc.2015.7320077] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Phase contrast MRI (pcMRI) was used to measure flow before and after placement of a flow diverter (n = 3). Decreases from 18% to 31% in flow velocity were seen in the inflow jet of the aneurysms. Flow patterns were also compared. It was observed that the gross aneurysmal flow patterns were maintained after flow diverter placement despite decreased fluid velocities. All measurements were carried out in 3D printed aneurysm replicas.
Collapse
|
7
|
Marginal fit of indirect composite inlays using a new system for manual fabrication. EUROPEAN JOURNAL OF PAEDIATRIC DENTISTRY 2016; 17:223-226. [PMID: 27759412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This in vitro study compares a new system for manual chair side fabrication of indirect composite restorations, which uses silicone models after alginate impressions, to CAD/CAM-technology and laboratory manual production techniques. MATRIALS AND METHODS: and study design Each 10 composite inlays were fabricated using different types of production techniques: CAD/CAM- technology (A), the new inlay system (B), plaster model after alginate impression (C) or silicone impression (D). The inlays were adapted into a metal tooth and silicone replicas of the cement gaps were made and measured. Statistical analysis was performed using ANOVA and Tukey's test. Results and Statistics In group A the biggest marginal gaps (174.9μm ± 106.2μm) were found. In group B the gaps were significantly smaller (119.5 μm ± 90.6 μm) than in group A (p=0.035). Between groups C (64.6 μm ± 68.0μm) and D (58.2 μm ± 61.7 μm) no significant differences could be found (p=0.998), but the gaps were significantly smaller compared with group B. Conclusion Chairside manufacturing of composite inlays resulted in better marginal precision than CAD/CAM technology. In comparison to build restorations in a laboratory, the new system is a timesaving and inexpensive alternative. Nevertheless, production of indirect composite restorations in the dental laboratory showed the highest precision.
Collapse
|
8
|
Evaluation of the In Vitro Effects of Cervical Marginal Relocation Using Composite Resins on the Marginal Quality of CAD/CAM Crowns. THE JOURNAL OF ADHESIVE DENTISTRY 2016; 18:355-62. [PMID: 27419242 DOI: 10.3290/j.jad.a36514] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To evaluate the effect of cervical margin relocation (CMR) for crowns designed using CAD/CAM technology, and made of pre-cured resin or lithium disilicate, before and after thermomechanical loading. The test hypothesis was that the marginal quality of the crowns would not be influenced by the CMR with composite resins before or after thermomechanical loading. MATERIALS AND METHODS Standard crown preparations were created in 40 human molars. The margins were located in enamel, except for the mesial proximal box, where the cervical margin was 2.0 mm below the cementoenamel junction, with 4.0 mm in the buccolingual and 2.0 mm in the mesiodistal dimension. For the CMR technique, a 2-mm layer of conventional or flowable composite resin was applied to the mesial box. Using the Cerec CAD/CAM system, 40 standard crowns were prepared, and restorations were luted using a dual-curing adhesive cement. SEM analysis was performed using epoxy resin replicas before and after loading to assess the marginal quality of interfaces of the mesial proximal box with CMR/crown and the distal face of the tooth without CMR. Statistical differences between groups were analyzed using the Kruskal-Wallis test and Bonferroni's post-hoc test. RESULTS The null hypothesis was accepted, since no statistically significant differences were found in marginal quality before and after thermomechanical cycling (p > 0.05). CONCLUSION The implementation of CMR before and after thermomechanical cycling had no effect on the quality of cervical margins. To establish whether CMR is a suitable procedure for the adhesive luting of composite resin crowns in deep proximal boxes, additional studies are required.
Collapse
|
9
|
Influence of Cavity Margin Design and Restorative Material on Marginal Quality and Seal of Extended Class II Resin Composite Restorations In Vitro. THE JOURNAL OF ADHESIVE DENTISTRY 2016; 18:7-16. [PMID: 26814320 DOI: 10.3290/j.jad.a35520] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To investigate the influence of three cavity designs on the marginal seal of large Class II cavities restored with low-shrinkage resin composite limited to the enamel. MATERIALS AND METHODS One hundred twenty (120) intact human molars were randomly divided into 12 groups, with three different cavity designs: 1. undermined enamel, 2. box-shaped, and 3. proximal bevel. The teeth were restored with 1. an extra-low shrinkage (ELS) composite free of diluent monomers, 2. microhybrid composite (Herculite XRV), 3. nanohybrid composite (Filtek Supreme XTE), and 4. silorane-based composite (Filtek Silorane). After artificial aging by thermocycling and storage in physiological saline, epoxy resin replicas were prepared. To determine the integrity of the restorations' approximal margins, two methods were sequentially employed: 1. replicas were made of the 120 specimens and examined using SEM, and 2. the same 120 specimens were immersed in AgNO3 solution, and the dye penetration depth was observed with a light microscope. Statistical analysis was performed using the Kruskal-Wallis and the Dunn-Bonferroni tests. RESULTS After bevel preparation, SEM observations showed that restorations did not exhibit a higher percentage of continuous margin (SEM-analysis; p>0.05), but more leakage was found than with the other cavity designs (p<0.05). The lowest percentage of continuous margin was observed in ELS restorations (p<0.05). More fractured margins were observed in the undermined enamel cavity design groups (p<0.05). CONCLUSION Bevel preparation failed to improve margin quality in large Class II composite restorations and is no longer recommended. However, undermined enamel should be removed to prevent enamel fractures.
Collapse
|
10
|
The Accuracy of Fit of Crowns Made From Wax Patterns Produced Conventionally (Hand Formed) and Via CAD/CAM Technology. THE EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY 2016; 24:10-17. [PMID: 27039473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
OBJECTIVE The aim of this study was to compare the marginal and internal fit accuracy of crowns constructed using three different wax production methods; conventional, milled, and 3D printed and utilizing three different cement gap thicknesses. METHODS 15 identical stone dies were made for each method. Wax patterns were produced and then cast into metal crowns, which were assessed for differences in accuracy of both marginal and internal fit. Measurement points were 4 points per crown; occlusal, axial, marginal gap, and marginal discrepancy points. A silicone impression technique and conventional cementation technique were employed to facilitate the measurements. RESULTS There was no significant difference (p > 0.05) in accuracy between the digitally and manually produced crowns, with the 3D printed crowns being slightly more accurate. Whereas, statistically significant differences were noticed between the conventional versus printed groups, in occlusal and marginal gap points (p < 0.05). CONCLUSION The marginal and internal fit of 3D printed wax patterns is more accurate than the other two production methods. The milling of wax crowns is as accurate as the conventional hand carved production in terms of internal and marginal fit. The manufacturer recommended offset/die-spacer of 30 μm produced the most accurate internal and marginal fits.
Collapse
|
11
|
Marginal and Internal Fit of Conventional Metal-Ceramic and Lithium Disilicate CAD/CAM Crowns. INT J PROSTHODONT 2015; 28:519-21. [PMID: 26340013 DOI: 10.11607/ijp.4089] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This study aimed to evaluate and compare the marginal and internal gap widths of lithium disilicate computer-aided design / computer-assisted manufacture (LDC) crowns and conventionally produced porcelain-fused-to-metal (PFM) crowns. A convenience sample of 21 patients treated with a single restoration was selected. PFM and LDC crowns were fabricated for each selected abutment tooth, following traditional crown preparation. Silicone replicas were produced, and internal gaps and marginal gaps were measured. Internal gaps were significantly larger for the axial and occlusal surfaces of LDC crowns than for those of PFM crowns (P < .001). Marginal gaps were not significantly different (P > .05). Both LDC crowns and PFM crowns showed clinically acceptable marginal fit.
Collapse
|
12
|
Abstract
BACKGROUND Available literature analysis demonstrated smallness of studies of cranial base. OBJECTIVES The goal of the study was to analyse the medial fossa of the human cranium in the foetal period against other fossae. MATERIAL AND METHODS Survey material consisted of 110 human foetuses at a morphological age of 16-28 weeks of foetal life, CRL 98-220 mm. Anthropological, preparation method, reverse method and statistical analysis were utilized. The survey incorporated the following computer programmes: Renishaw, TraceSurf, AutoCAD, CATIA. The reverse method seems especially interesting (impression with polysiloxane (silicone elastomer of high adhesive power used in dentistry) with 18 D 4823 activator. Elicited impression accurately reflected complex shape of cranium base. RESULTS On assessing the relative rate of cranium medial fossa, the rate was found to be stable (linear model) for the whole of the analysed period and is 0.19%/week, which stands for the gradual and steady growth of the middle fossa in relation to the whole of the cranium base. At the same time, from the 16th till 28th week of foetal life, relative volume of the cranium middle fossa increases more intensively than cranium anterior fossa, whereas the cranium middle fossa volume as compared with the cranium posterior fossa is definitely slower. In the analysed period, the growth rate of the cranium base middle fossa was bigger in the 4th and 5th weeks than in the 6th and 7th weeks of foetal life. The investigations revealed cranium base asymmetry of the left side. Furthermore, the anterior fossae volume on the left side is significantly bigger than the one of the fossae on the right side. CONCLUSIONS Volume growth rate is more intensive in the 4th and 5th than in the 6th and 7th weeks of foetal life. In the examined period, the relative growth rate of cranium base middle fossa is 0.19%/week and it is stable - linear model. The study revealed correlations in the form of mathematical models, which enabled foetuses age assessment.
Collapse
|
13
|
Abstract
Sequential replica method facilitates in vivo imaging of plant surface and provides data sufficient for detailed computation of geometry and growth. It enables obtaining a series of high-resolution images visualizing details of the examined surface. Series of molds, made in dental polymer, representing the examined surface are used to obtain casts in epoxy resin, which are in turn observed by scanning electron microscopy, while the structure itself remains intact. Images obtained from casts can be further used for data extraction, comprising 3D reconstruction and computation of local geometry and cell growth parameters. The sequential replica method is a universal method and can be applied to image complex shapes of a range of structures, like meristems, flowers, stems, leaves, or various types of trichomes. Different plant species growing in various conditions can be studied.
Collapse
|
14
|
Combining fiber dissection, plastination, and tractography for neuroanatomical education: Revealing the cerebellar nuclei and their white matter connections. ANATOMICAL SCIENCES EDUCATION 2014; 7:47-55. [PMID: 23839938 DOI: 10.1002/ase.1385] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2013] [Revised: 05/23/2013] [Accepted: 06/10/2013] [Indexed: 06/02/2023]
Abstract
In recent years, there has been a growing interest in white matter anatomy of the human brain. With advances in brain imaging techniques, the significance of white matter integrity for brain function has been demonstrated in various neurological and psychiatric disorders. As the demand for interpretation of clinical and imaging data on white matter increases, the needs for white matter anatomy education are changing. Because cross-sectional images and formalin-fixed brain specimens are often insufficient in visualizing the complexity of three-dimensional (3D) white matter anatomy, obtaining a comprehensible conception of fiber tract morphology can be difficult. Fiber dissection is a technique that allows isolation of whole fiber pathways, revealing 3D structural and functional relationships of white matter in the human brain. In this study, we describe the use of fiber dissection in combination with plastination to obtain durable and easy to use 3D white matter specimens that do not require special care or conditions. The specimens can be used as a tool in teaching white matter anatomy and structural connectivity. We included four human brains and show a series of white matter specimens of both cerebrum and cerebellum focusing on the cerebellar nuclei and associated white matter tracts, as these are especially difficult to visualize in two-dimensional specimens and demonstrate preservation of detailed human anatomy. Finally, we describe how the integration of white matter specimens with radiological information of new brain imaging techniques such as diffusion tensor imaging tractography can be used in teaching modern neuroanatomy with emphasis on structural connectivity.
Collapse
|
15
|
Primary enamel permeability: a SEM evaluation in vivo. EUROPEAN JOURNAL OF PAEDIATRIC DENTISTRY 2012; 13:231-235. [PMID: 22971262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
AIM The aim of this study was to evaluate in vivo the occurrence of outward fluid flow on primary tooth sound enamel surface. MATERIALS AND METHODS Sixty primary upper canines from preadolescent patients (mean age 8.0±1.9) and 24 retained primary upper canines from adult subjects (mean age 35.0±1.8) were analysed. The enamel surface was gently polished and air dried for 10 s. An impression was immediately obtained by vinyl polyxiloxane. Replicas were then obtained by polyether impression material, gold coated and inspected under SEM. The hydrophobic vinyl polyxiloxane material enabled to obtain in situ a morphological image of the presence of droplets, most likely resulting from outward fluids flow through outer enamel. For each sample three different representative areas of 5μ² in the cervical, medium and incisal third were examined and droplets presence values was recorded. All data were analysed by by Fisher's exact test. RESULTS Primary enamel showed a substantial permeability expressed as droplets discharge on its surface. Droplets distribution covered, without any specific localisation, the entire enamel surface in all the samples. No signs of post-eruptive maturation with changes in droplets distribution were observed in samples from adult subjects. No statistically significant differences (P = 0.955) were noted in the percentage distribution of enamel area covered with droplets among the two group studied. CONCLUSION SEM evaluation of droplets distribution on enamel surface indicated a substantial enamel permeability in primary teeth, accordingly with histological features, without changes during aging. A relationship between enamel permeability, caries susceptibility and bonding procedures effectiveness could be hypothesised.
Collapse
|
16
|
In vivo effect of titanium tetrafluoride and sodium monofluorophosphate dentifrice on remineralization: a preliminary split-mouth clinical trial. GENERAL DENTISTRY 2012; 60:e249-e254. [PMID: 22782060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The aim of this preliminary, split-mouth clinical trial was to evaluate how incipient carious lesions on permanent tooth enamel were affected by 4% titanium tetrafluoride (TiF4) when used with a sodium monofluorophosphate (MFP) dentifrice. Eight children were selected for this study, providing 18 pairs of permanent anterior teeth with incipient carious lesions. TiF4 was applied once to half of the sample teeth, while all teeth were brushed with the MFP dentifrice for four weeks. Clinical (texture, size, and brightness) and illustrative (photos and scanning electronic microscope replica) evaluations were performed. Descriptive-statistical analysis of the data was performed by analyzing pairs of teeth, using statistical software. Remineralization occurred in 13 of the 18 pairs of teeth that received both forms of treatment; seven pairs were partially remineralized while six pairs showed total remineralization (McNemar test: p = 0.375). Teeth treated with both TiF4 and MFP showed a 74.5% reduction in lesion size, compared to a 67% reduction in teeth treated with the MFP dentifrice only. The results indicate that a single application of TiF4 in conjunction with toothbrushing with a fluoride-containing dentifrice was no more effective than the use of dentifrice alone for treating incipient carious lesions.
Collapse
|
17
|
Clinical wear rate of direct and indirect posterior composite resin restorations. INT J PERIODONT REST 2012; 32:e87-e94. [PMID: 22408783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The purpose of this randomized clinical trial was to determine the clinical wear behavior of three nanofilled composites (Filtek Supreme XT [FS], Tetric EvoCeram [TEC], and Aelite Aesthetic [AA]) with two indirect composites (Estenia [E] and Tescera ATL [TATL]) on permanent molar teeth. Fifty-four patients whose treatment plans included moderate Class I and/or II restorations on molar teeth were selected for inclusion in this study. Wear was measured by use of gypsum replicas at baseline and 6 and 12 months using three-dimensional scanning and rapid-form software to elucidate the wear mechanisms. For statistical analyses, one-way analysis of variance and the Scheffe test were used. Statistical results revealed that wear behavior of TATL was significantly different from that of AA (P < .05). No significant differences were detected between AA and E (P > .05) or between TEC, FS, and TATL composite resins (P > .05). The results showed similar clinical performance between the five composite resins evaluated. Therefore, composite resins may be indicated for the restoration of posterior teeth. However, the composition of the composite resin did affect the wear behavior of the composite material.
Collapse
|
18
|
A replica technique for studying the effect of fluoride solutions on enamel erosion. SWEDISH DENTAL JOURNAL 2012; 36:169-178. [PMID: 23421307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
UNLABELLED The aim of this in vitro study was to develop a replica technique aimed at reproducing an enamel surface exposed to erosive challenge. The replica technique was then used to compare the effect of treating enamel with different fluoride (F) solutions using an in vitro erosion model. Human molar teeth were split in two (total n=34 specimens), and half of each specimen was isolated with impression material. Part I: 10 specimens were exposed to either 0.18% or 1.8% citric acid, the impression material was removed and replicas were prepared. All specimens and replica models were analysed by profilometry and SEM. Part II: 24 specimens were treated with native 0.1 mol/L F-solutions (HF, SnF2, NaF and TiF4), the impression material was removed, and the specimens were then exposed to 1.8% citric acid. Replicas were prepared and analysed by profilometry and SEM. The median height difference between the F-treated areas and the non-treated areas for each F-solution was measured. SEM micrographs were analysed qualitatively blind bytwo of the authors. RESULTS Part I--Replicas showed good topographical reproduction of the tooth specimens. Part II--HF had a significantly greater erosion-inhibiting effect than the other fluoride solutions at 0.1 mol/L F as shown by profilometry. SEM revealed a clearly defined border between F-treated and non-treated surfaces only for specimens treated with HF- and TiF solutions. In conclusion, the present replica technique was able to differentiate between the effect of treating enamel with different fluorides against dental erosion in vitro. The technique should be tested further for possible use in situ and in vivo.
Collapse
|
19
|
Wear of dental sealing materials using the replication technique. EUROPEAN JOURNAL OF PAEDIATRIC DENTISTRY 2011; 12:95-98. [PMID: 21668279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
AIM The aim of the present study was an in vivo evaluation of the wear of different sealing materials using the replication technique. MATERIALS AND METHODS Four different sealing materials were randomly applied on 2 out of 4 caries-free permanent first molars of each patient. Impressions were taken at T0: before the sealing material was applied; T1: right after the application; T2: 6 months after the application, and T3: 1 year after the application. The impressions were then processed for scanning electron microscopy analysis of the wear of the examined materials. Statistical analysis was used to evaluate differences among and within the 4 groups. RESULTS At T2, the average ratio of residual material in all the groups was 62.37% ± 1.21%, while at T3 it was 49.63% ± 1.11%. At both T2 and T3 there were no statistically significant differences among the 4 groups examined (p=0.76 and p=0.50 respectively). Comparison within the same group at T2 and T3 showed that statistically significant differences were only detected in group D (p=0.015). CONCLUSION Sealing materials do not undergo a complete loss after 1 year of application, thus indicating that they are suitable for caries prevention.
Collapse
|
20
|
Surface characteristics of zirconia-based posterior restorations: clinical and scanning electron microscopic analysis. JOURNAL (CANADIAN DENTAL ASSOCIATION) 2011; 77:b31. [PMID: 21507284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
AIM The aim of this prospective clinical trial was to evaluate the performance of zirconia-based all-ceramic posterior fixed partial dentures (FPDs) after 4 years of clinical use. MATERIALS AND METHODS Fifteen patients who needed 3- or 4-unit posterior FPDs were enrolled in the study. One manufacturer fabricated all restorations, following established clinical protocols and using computer-aided design/computer-aided manufacturing technology and one veneering material. Survival and success were evaluated clinically. Impressions were taken immediately after definitive cementation and after 48 months. Gold-coated epoxy replicas of the restorations were analyzed with scanning electron microscopy (SEM). Surface alterations were also evaluated clinically. RESULTS After 48 months, the survival rate for the FPDs was 100%. Three restorations exhibited minor chipping, for a fracture rate of 20% after 4 years. Thirty (59%) of the 51 individual restoration units revealed clinically rough occlusal surfaces, a finding that was confirmed by SEM. CONCLUSION The placement of 3- and 4-unit zirconia-based posterior FPDs can be considered a reliable treatment modality for medium-term clinical use. However, surface alterations of the veneering ceramics were observed after 4 years and are of notable clinical concern.
Collapse
|
21
|
Nanohybrid composite vs. fine hybrid composite in extended class II cavities: clinical and microscopic results after 2 years. AMERICAN JOURNAL OF DENTISTRY 2009; 22:228-234. [PMID: 19824560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
PURPOSE To evaluate the clinical behavior of two different resin composites in Class II cavities over a period of 2 years in a controlled prospective split-mouth study. METHODS 30 subjects received 68 direct resin composite restorations (Grandio bonded with Solobond M: n=36, Tetric Ceram bonded with Syntac: n=32) by one dentist in a private practice. All restorations were replacement restorations, 24 cavities (35%) revealed no enamel at the bottom of the proximal box, in 33 cavities (48%) the proximal enamel width was < 0.5 mm. The restorations were examined according to modified USPHS criteria at baseline, and after 0.5, 1, and 2 years. At each recall, impressions were taken to prepare replicas. Replicas of 44 selected subjects were assessed for marginal quality under a stereo light microscope (SLM) at x130, and 22 replicas were assessed under a SEM at x200. RESULTS Both recall rate and survival rate were 100% after 2 years of clinical service. No significant difference was found between the restorative materials (P > 0.05; Mann-Whitney U-test). A significant deterioration was found over time for marginal integrity, tooth integrity, restoration integrity and proximal contact (P < 0.05; Friedman test). SLM and SEM analysis of restoration margins only revealed differences in the amount of detectable perfect margins, in favor of Tetric Ceram (P < 0.05). Both materials performed satisfactorily over the 2-year observation period.
Collapse
|
22
|
Cementogenesis examined from the viewpoint of microcirculation. INT J PERIODONT REST 2009; 29:267-275. [PMID: 19537466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The purpose of this study was to perform a three-dimensional observation, via microvascular corrosion casts, of the microcirculation system during deposition of cementum after flap surgery and to investigate the permeable structure of the vascular endothelium. Two stages of wound healing after flap surgery were confirmed based on successive vascular changes. The transition between these stages occurred 3 weeks after surgery, at which time new blood vessels disappeared and an early stage of accumulation of new cementum was apparent. Hence, fibrous repair occurred during the first stage, and repair of hard tissue (ie, formation of cementum) occurred during the second stage. These findings suggest that metabolic activity in cementogenesis is low, based on the condition of the blood vessels, and therefore new cementum is not easily formed.
Collapse
|
23
|
Marginal adaptation of root-end filling materials: an in vitro study with teeth and replicas. J Contemp Dent Pract 2009; 10:75-82. [PMID: 19279975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
AIM The purpose of this investigation was to evaluate the marginal adaptation of five root-end filling materials. METHODS AND MATERIALS Fifty human single-rooted teeth were resected 3 mm from the apex. Root-end cavities were then prepared using an ultrasonic tip and filled with one of the following materials: silver amalgam without zinc, white MTA-Angelus, white Portland cement (PC), Vitremer, and GC Fuji Ortho LC. The apical portion of the roots was then sectioned to obtain two 1 mm thick transversal sections. Epoxy resin replicas of these apical sections were fabricated for an analysis of marginal adaptation. Scanning electron microscopy (SEM) was used to determine gaps in the adaptation of the root-end filling materials at the interface between them and the dentin. The Kruskal-Wallis test and a multiple comparison test were used for statistical data analysis. The Spearman correlation coefficient was used to determine the correlation between the results found for teeth and replicas. RESULTS Materials containing calcium oxide (MTA and PC) showed similar results. Resin modified glass ionomer cements (GICs) presented similar variations in marginal adaptation, but Vitremer showed significantly greater marginal adaptation when compared to GC Fuji Ortho LC. CONCLUSION A positive and significant correlation was observed between marginal adaptation values found in the teeth and their replicas. CLINICAL SIGNIFICANCE The use of ionomers as root-end filling materials may improve clinical outcomes in periradicular surgery.
Collapse
|
24
|
Development of an in situ methodology for the clinical evaluation of dentine hypersensitivity occlusion ingredients. THE JOURNAL OF CLINICAL DENTISTRY 2009; 20:158-166. [PMID: 19902640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
OBJECTIVE The aim of these clinical studies was to evaluate an in situ dentine tubule occlusion model, and to determine the occluding effect from novel occluding agents on patent dentine tubules compared to a positive control (8% strontium acetate--Sensodyne Mint) and negative control (a non-occluding agent) after four days of brushing treatment. METHODS These two in situ clinical studies were of single-center, randomized, crossover, single-blind design. Healthy participants wore two lower intra-oral appliances retaining four dentine samples for four treatment days for each period of the study. Samples were power-brushed each day with the test product. Assessment utilized surface topological analysis with a replica-based methodology under scanning electron microscopy (SEM). RESULTS Both clinical trials demonstrated that the positive control (8% strontium acetate) occluded dentine tubules significantly better (p = 0.0007; p < 0.0009) than the negative controls in the two studies, respectively. The experimental occluding agents demonstrated varying degrees of success for occluding effect compared to the controls. CONCLUSION The methodology clearly demonstrates that this in situ clinical model can robustly and reproducibly detect the dentine tubular occlusive effects of positive and negative controls in the treatment of dentine hypersensitivity brushed on the dentine surface. Using this methodology, new occlusion agents for the relief of dentine hypersensitivity can be assessed for occlusive effects on dentine.
Collapse
|
25
|
Selective enamel etching reconsidered: better than etch-and-rinse and self-etch? THE JOURNAL OF ADHESIVE DENTISTRY 2008; 10:339-344. [PMID: 19058678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
PURPOSE This study evaluated the marginal quality of differently bonded direct resin composite restorations in enamel and dentin, before and after thermomechanical loading (TML). Special attention was focussed on the performance of selective enamel etching, etch-and-rinse, and self-etching adhesives. MATERIALS AND METHODS Eighty MO cavities with proximal margins beneath the cementoenamel junction were prepared in extracted human third molars. Direct resin composite restorations (Tetric EvoCeram, n=8) were placed with 4-step selective enamel etching (Syntac SE), 4-step etch-and-rinse (Syntac ER), 2-step etch-and-rinse (XP Bond, Scotchbond 1 XT/Single Bond Plus), 2-step self-etching (AdheSE, Clearfil SE Bond), 2-step self-etching with selective enamel etching (AdheSE SE, Clearfil SE Bond SE), and 2-step self-etching with etch-and-rinse (AdheSE TE, Clearfil SE Bond TE). Marginal gaps were analyzed using epoxy resin replicas under a scanning electron microscope at 200X magnification. RESULTS Initially, high percentages of gap-free margins were identified for all adhesives. After TML, the results were as follows: (A) Enamel margins: When phosphoric acid was used on enamel, results were constantly higher (approximately 90%) compared with two-step self-etchin adhesives (approximately 70%; p < 0.05). (B) Dentin margins: No statistical differences were found when etch-and-rinse and selective etch approaches were compared (59% to 64%; p > 0.05). When self-etching adhesives were used as per manufacturers' directions, dentin margins exhibited the best marginal quality (74% to 82%; p < 0.05). When self-etching adhesives were used under etch-and-rinse conditions, marginal quality in dentin was significantly reduced to 35% to 42% (p < 0.05). CONCLUSION Enamel bonding was generally more effective with phosphoric-acid etching. Enamel bonding performance of 2-step self-etching adhesives was improved when phosphoric acid was applied on enamel selectively.
Collapse
|
26
|
How can droplet formation occur in endodontically treated teeth during bonding procedures? THE JOURNAL OF ADHESIVE DENTISTRY 2008; 10:211-218. [PMID: 18652270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
PURPOSE The aim of this in vivo study was to clarify how blistering formation occurs along intraradicular dentin bonded interfaces. MATERIALS AND METHODS Patients were selected and post space was prepared in vivo in endodontically treated teeth. Post space was etched, dried with ethanol, and bonded with one of the following adhesive systems: All Bond 2, XP-Bond, Clearfil SE Bond, Xeno III. The four adhesives were considered as representative of each bonding system class. An additional group was prepared with phosphoric acid treatment + application of Pre-Bond unfilled resin of All Bond 2, without the use of the primer agent. Etching was avoided for self-etching materials. Replicas of the post space were taken (1) after post space preparation; (2) after etching, rinsing, and drying; (3) after ethanol drying, and (4) after adhesive application. Replicas were analyzed with SEM and blisters were counted by independent observers. Statistical analysis was performed with Kruskal-Wallis ANOVA and Dunn's multiple comparison tests at p = 0.05. RESULTS No blister formation occurred on replicas taken prior to adhesive application, while blister formation was evident in all replicas of bonded interfaces, irrespective of the adhesive system. No statistical difference in the number of droplets was found between All Bond 2, XP-Bond, and Clearfil SE Bond. Xeno III exhibited the highest number of blisters. Specimens bonded with Pre-Bond unfilled resin of All Bond 2 without primer application showed no blister formation. CONCLUSION This study revealed that blister formation occurs only if the priming agent of the adhesive system was applied, thus supporting the hypothesis that blistering occurs due to adhesive phase separation or insufficient solvent evaporation.
Collapse
|
27
|
The effects of ozone gas application on shear bond strength of orthodontic brackets to enamel. AMERICAN JOURNAL OF DENTISTRY 2008; 21:35-38. [PMID: 18435374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
PURPOSE To investigate the possibility that ozone may have an adverse effect on the bond strength of orthodontic brackets and to determine the area of residual adhesive on teeth after the debonding of brackets. METHODS 60 extracted premolars teeth were used in this study. Resin coated APC brackets (3M) were bonded according to the manufacturers' instructions. Bonded teeth were randomly divided into two groups. The teeth in Group 1 were subjected to a 10-second dosage of ozone from the HealOzone unit (Kavo) after etching and to a further 10 seconds of ozone after bonding the brackets using a 5 mm delivery cup. Teeth in Group 2 were used as a control. Debonding was carried out using a testing instrument at a cross-head speed of 1 mm/minute. RESULTS The Mann-Whitney test revealed no significant differences in shear bond strength between the two groups (P = 0.337). The mean shear bond strength (11.66 MPa) of Group 1 (subjected to ozone) was not significantly different than the mean shear bond strength (10.88 MPa) of Group 2 (not subjected to ozone). A Pearson Chi-square test of the Adhesive Remnant Index (ARI) revealed no significant difference in residual adhesive among the groups tested.
Collapse
|
28
|
Clinical performance and wear characteristics of veneered lithia-disilicate-based ceramic crowns. Dent Mater 2007; 24:667-73. [PMID: 17727943 PMCID: PMC2346544 DOI: 10.1016/j.dental.2007.06.033] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2007] [Accepted: 06/08/2007] [Indexed: 11/16/2022]
Abstract
OBJECTIVES The objectives of this study were to characterize the clinical performance and wear characteristics of lithia-disilicate-based ceramic crowns. METHODS Thirty posterior crowns were made using the heat-pressing technique and lithia-disilicate-based core ceramic. Subjects were recalled annually. The quality of crowns and adjacent gingival tissues were examined using nine criteria for acceptability. All crowns were examined and ranked from 4 (Excellent) to 1 (Unacceptable) for each criterion. Impressions were made for replica models at each appointment. Wear characteristics of dental ceramic and enamel were obtained by comparing the surface of the original model with the follow-up model using a laser scanner. RESULTS Twenty-nine subjects returned for the 1-year recall examination. The maximum clenching force for the 30 subjects ranged from 125 to 815 N. All clinical criteria were ranked good to excellent at the 1-year recall exam and no fractures were observed. The mean occlusal wear volumes for the ceramic crowns after 1 year were 0.19 (0.065)mm3 for premolar sites and 0.34 (0.08)mm3 for molar sites. The mean occlusal wear volumes of opposing enamel after 1 year were 0.21 (0.06)mm3 for premolar teeth and 0.50 (0.22)mm3 for molar teeth. The mean occlusal wear volume of ceramic molar crowns was significantly lower than the volume of enamel wear of the opposing teeth (p<or=0.05). CONCLUSIONS The quality of the overall prostheses and the gingival tissues were acceptable after 1 year. The mean occlusal wear volume of ceramic molar crowns was significantly lower than the enamel wear volume of the opposing teeth.
Collapse
|
29
|
Abstract
The botulinum toxin A (BTX-A) role on elimination of hyperkinetic wrinkles is consolidated, although relying on subjective methods of assessment. A prospective open-label study was performed on 10 patients to objectively analyze superficial skin texture changes caused by BTX-A in the glabellar area. Skin areas were reproduced by silicon replica technique at baseline, 1 month, and 6 months after treatment. Takahashi's parameters (roughness, anisotropy, microsulcus number, and width) were obtained from scanning electron microscopy (SEM) analysis and compared using the Wilcoxon signed rank test. SEM images showed skin texture changes, and software analysis gave parameters for statistical analysis, allowing an objective evaluation. Statistically significant parameter modifications were evidenced. BTX-A effectiveness in wrinkle treatment was confirmed, and no differences in skin texture parameters from baseline to toxin action end were noted.
Collapse
|
30
|
Abstract
The aim of this study was to visualize fluid movement through dental enamel in vivo. Fifty permanent upper central incisors, from subjects aged 10-70 yr, and 5 permanent central just-erupted incisors, from subjects aged 6-7 yr, were included in the study. An impression was obtained by vinyl polyxiloxane, and replicas were then obtained by polyether impression material. The hydrophobic vinyl polyxiloxane material yielded a morphological image in situ of outward fluid flow through tooth enamel. The study confirmed in vivo that enamel is a permeable substrate, as shown by the presence of droplets on its surface, and demonstrated that age and enamel permeability are closely related. Samples from subjects of different ages showed a decreasing number and size of droplets with increasing age: freshly erupted permanent teeth showed many droplets covering the entire enamel surface. Droplets in permanent teeth were prominent along enamel perikymata.
Collapse
|
31
|
Effect of simulated pulpal pressure on dentin permeability and adhesion of self-etch adhesives. Dent Mater 2007; 23:705-13. [PMID: 16904175 DOI: 10.1016/j.dental.2006.06.010] [Citation(s) in RCA: 97] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2006] [Accepted: 06/19/2006] [Indexed: 10/24/2022]
Abstract
OBJECTIVES Dentin bonds made with one-bottle etch-and-rinse and self-etch adhesives are affected by the formation of interfacial blisters, porosities and deterioration. The first objective of this study was to evaluate the fluid flow through resin-dentin interfaces created by self-etching adhesives applied to deep dentin using a replica technique and by directly measuring dentin permeability (P). The second objective was to examine the effect of intrapulpal pressure on the microtensile bond strength of these adhesives. METHODS A fluid-transport model was used to measure the fluid permeability (%P) through different adhesives. Impressions of bonded dentin were taken with a polyvinylsiloxane impression material to monitor fluid transudation from the surface of the adhesive. Positive replicas were fabricated for SEM examination. Two groups of resin-bonded specimens (pulpal pressure versus no pulpal pressure) were created for microtensile bond strength evaluation. Adhesive application was performed under 0 cm H(2)O. Pulpal pressure group was submitted to 20 cm H(2)O of pulpal pressure during build-up procedures. RESULTS Clearfil Protect Bond exhibited the lowest permeability and fewest numbers of fluid droplets over the surface of the bonded dentin. G-Bond and Clearfil-S3 Bond were more permeable than Clearfil Protect Bond. One Up Bond F was the most permeable adhesive. A highly significant correlation was observed between the relative permeability of these adhesives (%P) and the number of fluid droplets on the adhesive surfaces. The application of pulpal pressure significantly reduced bond strength. SIGNIFICANCE Resin-dentin bonds created by contemporary self-etch adhesives are susceptible to fluid permeation induced by pulpal pressure. HEMA-based adhesives showed the largest reductions in bond strengths after pulpal pressure application.
Collapse
|
32
|
Marginal adaptation after aging of a self-etching adhesive containing an antibacterial monomer. THE JOURNAL OF ADHESIVE DENTISTRY 2007; 9:311-7. [PMID: 17655071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
PURPOSE To evaluate the marginal adaptation of mixed Class V cavities restored with Clearfil Protect Bond (Kuraray), Clearfil SE Bond (Kuraray), and two experimental combinations of both marketed adhesives, after fatigue and water storage. MATERIALS AND METHODS Four groups (Clearfil Protect Bond, Clearfil SE Bond, Exp. 1 and Exp. 2) of Class V cavities were restored with a microhybrid restorative composite (Clearfil APX, Kuraray). The marginal quality of these restorations was quantified by evaluation of gold-coated epoxy replicas with scanning electron microscopy before loading, after loading, and after a 12-month period of water storage. Data from marginal adaptation along the total margin length, on enamel, and on dentin were analyzed with the Wilcoxon signed rank test for differences within a group and with Kruskal-Wallis in order to assess the differences between groups. The Bonferroni test was used for post-hoc comparisons, and the confidence level was set to 95%. RESULTS The mean percentages (+/-SD) of "continuous margin" of the total marginal length ranged from 79.5% (+/-13.3) to 62.2% (+/-10.4) and from 70% (+/-11) to 61% (+/-15.1) after loading and after storage, respectively. No significant differences could be detected amongthe different groups. However, the marginal adaptation of Clearfil Protect Bond remained the most stable of all materials tested, as no significant differences were detected between the percentages of continuous margins before loading, after loading, or after storage. CONCLUSIONS The use of an antibacterial adhesive system was as effective as the conventional two-step self-etching adhesive in the marginal adaptation of Class V restorations.
Collapse
|
33
|
New Tetrasilicate Cements as Retrograde Filling Material: An In Vitro Study on Fluid Penetration. J Endod 2007; 33:742-5. [PMID: 17509418 DOI: 10.1016/j.joen.2007.02.008] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2006] [Revised: 02/01/2007] [Accepted: 02/10/2007] [Indexed: 11/30/2022]
Abstract
We aimed to compare the apical sealing ability of two experimental retrograde root-filling cements and mineral trioxide aggregate using a fluid filtration method. X-ray diffraction (XRD) and X-ray fluorescence spectrometry (XRF) were used to evaluate structural and qualitative characteristics. Thirty single-rooted extracted teeth were treated, root-end prepared, and obturated using MTA and two experimental cements. Fluid filtration was measured during a 5-minute period after 4, 24, and 48 hours and 1, 2, and 12 weeks. The results were statistically compared by using a two-way analysis of variance (p < 0.05). The marginal adaptation was evaluated by using a SEM replica technique. XRD analyses showed similar patterns. XRF showed lower amounts of SiO(2) and FeO(3) in the experimental cements. All cements showed a reduced fluid flow rate over time. No significant differences were found between the cements. The SEM replica indicated a good marginal adaptation to dentinal walls. Both experimental cements showed suitable properties as retrograde root-filling materials.
Collapse
|
34
|
High-resolution quantitative visualization of glutamate and GABA receptors at central synapses. Curr Opin Neurobiol 2007; 17:387-93. [PMID: 17499496 DOI: 10.1016/j.conb.2007.04.012] [Citation(s) in RCA: 90] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2007] [Accepted: 04/27/2007] [Indexed: 01/28/2023]
Abstract
Glutamate and GABA are the main transmitters in the central nervous system and their effects are mediated by ionotropic and metabotropic receptors. Immunogold electron microscopy has revealed the quantitative localization of these receptors at 20-30nm resolution. SDS-digested freeze-fracture replica labeling (SDS-FRL), a newly developed immunogold method, provides an accurate estimate of molecule numbers. Here, we summarize the recent advances in quantitative receptor localization, including use of SDS-FRL analyses to determine numbers of AMPA-type glutamate receptors in the cerebellum. The two-dimensional view and high sensitivity of SDS-FRL have revealed small, irregularly shaped AMPA receptor clusters within cerebellar synapses.
Collapse
|
35
|
Anatomical and clinical study of lingual arterial chemoembolization for tongue carcinoma. ACTA ACUST UNITED AC 2007; 103:e1-5. [PMID: 17317232 DOI: 10.1016/j.tripleo.2006.11.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2006] [Revised: 10/02/2006] [Accepted: 11/09/2006] [Indexed: 01/23/2023]
Abstract
OBJECTIVE The aim of this study was to develop an alternative treatment approach using lingual artery chemoembolization for certain tongue carcinomas. STUDY DESIGN Fifty-three lingual artery, postmortem, cast human specimens were studied. Seventy-eight patients with tongue carcinoma were chemoembolized with Car-platinum microcapsules. RESULTS The deposition of the microcapsule embolism was approximately at the fifth- to the sixth-branch level of the deep lingual artery. The results complied with the anatomy, and the clinical outcomes were effective. CONCLUSIONS Lingual artery chemoembolization showed efficacy for curing carcinoma in the midmargin and midbody areas of the tongue, within the limitations of this study.
Collapse
|
36
|
Number and density of AMPA receptors in individual synapses in the rat cerebellum as revealed by SDS-digested freeze-fracture replica labeling. J Neurosci 2007; 27:2135-44. [PMID: 17314308 PMCID: PMC6673557 DOI: 10.1523/jneurosci.2861-06.2007] [Citation(s) in RCA: 146] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The number of AMPA receptor (AMPAR) is the major determinant of synaptic strength at glutamatergic synapses, but little is known about the absolute number and density of AMPARs in individual synapses. Using SDS-digested freeze-fracture replica labeling, which has high detection efficiency comparable with electrophysiological noise analysis for functional AMPAR, we analyzed three kinds of excitatory synapses in the molecular layer of the adult rat cerebellum. In parallel fiber (PF)-Purkinje cell (PC) synapses, we found large variability in the number (38.1 +/- 34.4 particles per synapse, mean +/- SD; range, 2-178 particles per synapse) and density (437 +/- 277 particles/microm2; range, 48-1210 particles/microm2) of immunogold-labeled AMPARs. Two-dimensional view and high sensitivity of this method revealed irregular-shaped small AMPAR clusters within synapses. Climbing fiber (CF)-PC synapses had higher number of AMPAR labeling (68.6 +/- 34.5 particles per synapse) than PF-PC and PF-interneuron synapses (36.8 +/- 14.4 particles per synapse). Furthermore, AMPAR density at CF-PC and PF-interneuron synapses was approximately five times higher and more uniform than that at PF-PC synapses. These results suggest input- and target-dependent regulation of AMPAR-mediated synaptic strength.
Collapse
|
37
|
Fractographic ceramic failure analysis using the replica technique. Dent Mater 2007; 23:1397-404. [PMID: 17270267 PMCID: PMC2077838 DOI: 10.1016/j.dental.2006.12.002] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2006] [Accepted: 12/06/2006] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To demonstrate the effectiveness of in vivo replicas of fractured ceramic surfaces for descriptive fractography as applied to the analysis of clinical failures. METHODS The fracture surface topography of partially failed veneering ceramic of a Procera Alumina molar and an In-Ceram Zirconia premolar were examined utilizing gold-coated epoxy poured replicas viewed using scanning electron microscopy. The replicas were inspected for fractographic features such as hackle, wake hackle, twist hackle, compression curl and arrest lines for determination of the direction of crack propagation and location of the origin. RESULTS For both veneering ceramics, replicas provided an excellent reproduction of the fractured surfaces. Fine details including all characteristic fracture features produced by the interaction of the advancing crack with the material's microstructure could be recognized. The observed features are indicators of the local direction of crack propagation and were used to trace the crack's progression back to its initial starting zone (the origin). Drawbacks of replicas such as artifacts (air bubbles) or imperfections resulting from inadequate epoxy pouring were noted but not critical for the overall analysis of the fractured surfaces. SIGNIFICANCE The replica technique proved to be easy to use and allowed an excellent reproduction of failed ceramic surfaces. It should be applied before attempting to remove any failed part remaining in situ as the fracture surface may be damaged during this procedure. These two case studies are intended as an introduction for the clinical researcher in using qualitative (descriptive) fractography as a tool for understanding fracture processes in brittle restorative materials and, secondarily, to draw conclusions as to possible design inadequacies in failed restorations.
Collapse
|
38
|
Buccal and palatal talon cusps with pulp extensions on a supernumerary primary tooth. Dentomaxillofac Radiol 2007; 35:469-72. [PMID: 17082342 DOI: 10.1259/dmfr/64715224] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
This paper reports an unusual occurrence of talon cusp on a supernumerary primary incisor, presenting on both labial and palatal sides. The tooth was scheduled for extraction due to its interference with the occlusion. Morphometric analysis of the taloned cusps was performed on digitized replicas of the tooth crown using open-source image analysis toolkit (ImageJ). Further non-destructive investigation of the taloned crown under cone-beam X-ray computed tomography revealed pulpal extensions in both talon cusps.
Collapse
|
39
|
Comparison of self-reported lifetime sun exposure with two methods of cutaneous microtopography. Am J Epidemiol 2007; 165:222-30. [PMID: 17101707 DOI: 10.1093/aje/kwk004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
There is currently no "gold standard" for measuring lifetime sun exposure. Exploration of alternatives to self-reports is important for examining illnesses related to ultraviolet light exposure. Using skin replicas obtained from 184 controls in a breast cancer case-control study (Toronto, Ontario, Canada, 2004-2005), the authors compared self-reported indicators of lifetime sun exposure with two measures of cutaneous microtopography, the Beagley-Gibson system and skin line counts. With the Beagley-Gibson system, significantly increased odds ratios were found for age (odds ratio (OR) = 1.10, 95% confidence interval (CI): 1.05, 1.16), spending 7 days outside per week during the summer (OR = 3.33, 95% CI: 1.48, 7.50), and lifetime number of sunlamp sessions. Significantly decreased odds ratios were found for having darker skin, ever giving birth, and ever using sunlamps. With the skin line count approach, significant positive associations were found for age (OR = 2.31, 95% CI: 1.23, 4.35), age squared, duration of working in outdoor jobs (OR = 0.88, 95% CI: 0.79, 0.98), and average number of outdoor activities per week at ages 20-29 years (OR = 1.05, 95% CI: 1.00, 1.10). While the Beagley-Gibson method was associated with more variables than the skin line count method, both methods require further refinement before graded skin replicas can be recommended as a substitute for self-report measures.
Collapse
|
40
|
Abstract
The aim of this study was to evaluate the marginal adaptation of class II ceromer (Targis, Vivadent) indirect inlay restorations under both in vivo and in vitro conditions. Twenty Targis inlays were produced for class II inlay cavities (13 mandibular and seven maxillary teeth) in 20 patients. The in vivo adaptation of the inlay to the tooth cavity was evaluated by means of silicone replica technique. For in vitro evaluation, 20 mesio-occluso-distal (MOD) Targis inlays were made in extracted upper molars. Half of the inlays were cemented with Variolink high-viscosity resin cement while the other half was cemented with Variolink Ultra. The replica specimens and in vitro samples were sectioned buccolingually and mesiodistally, and marginal adaptation was evaluated at both proximal and occlusal margins at 200x magnification under a light microscope. The data was analyzed with anova (P < 0.05). The in vivo mean film thickness values for occlusal and proximal locations were recorded as 73 and 132 microm respectively. In vitro mean marginal fit values were observed as 48 and 67 microm for occlusal and proximal margins of inlays luted with Variolink II high viscosity. The marginal fit values recorded under in vivo conditions were higher in magnitude than the measurements obtained under in vitro conditions. The use of a highly filled resin luting agent with an ultrasonic insertion technique did not cause an increase in marginal gap width of the inlay.
Collapse
|
41
|
Surface microtopographies of tropical sea stars: lack of an efficient physical defence mechanism against fouling. BIOFOULING 2007; 23:419-29. [PMID: 17899470 DOI: 10.1080/08927010701570071] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
The role of surface topography as a defence against fouling in tropical sea stars was investigated. The sea stars Linckia laevigata, Fromia indica, Cryptasterina pentagona and Archaster typicus are not fouled and have paxillae (modified ossicles with a median vertical pillar) on their aboral surfaces, which varied in diameter, height and distance depending on species and position on the aboral surface, providing unique and complex surface microtopographies for each species. The surfaces of the sea stars L. laevigata, F. indica and A. typicus were moderately wettable, with their mean seawater contact angles, calculated from captive bubble measurements, being 60.1 degrees, 70.3 degrees and 57.3 degrees, respectively. The seawater contact angle of C. pentagona could not be measured. To evaluate the effectiveness of the surface microtopographies in deterring the settlement of fouling organisms, field experiments with resin replicas of the four sea star species were conducted at three sites around Townsville, Australia, for 8 weeks during the dry and wet seasons. The fouling community and total fouling cover did not differ significantly between replicas of L. laevigata, F. indica, C. pentagona, A. typicus and control surfaces at any site during the dry season. Significant differences between fouling communities on the replicas of the sea stars and control surfaces were detected at two sites during the wet season. However, these differences were transitory, and the total fouling cover did not differ significantly between replicas of sea stars and control surfaces at two of the three sites. In contrast to recent literature on the effects of biofouling control by natural surfaces in the marine environment, the surface microtopographies of tropical sea stars alone were not effective in deterring the settlement and growth of fouling organisms.
Collapse
|
42
|
Transmission electron microscopy and scanning probe microscopy. METHODS OF BIOCHEMICAL ANALYSIS 2006; 37:73-115. [PMID: 7508542 DOI: 10.1002/9780470110584.ch2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
43
|
Clinical wear of posterior metal-free polymer crowns. One-year results from a randomized clinical trial. J Dent 2006; 35:246-52. [PMID: 17027139 DOI: 10.1016/j.jdent.2006.09.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2006] [Revised: 08/30/2006] [Accepted: 09/02/2006] [Indexed: 10/24/2022] Open
Abstract
OBJECTIVES The purpose of this randomized clinical trial was to evaluate the clinical wear behavior of posterior, metal-free polymer crowns, with and without a glass-fiber framework, and to compare it with that of metal-ceramic crowns. METHODS Eighty single crowns manufactured from a newly designed polymer composite were set in posterior teeth. Half of these received a glass-fiber framework (group 1) whereas half were prepared without framework stabilization (group 2). All polymer crowns were adhesively luted with resin cement. As the control group, 40 conventional metal-ceramic crowns were inserted with hybrid cement. Wear was measured, by use of gypsum replicas, at baseline and after 12 months, by use of a 3D laser scanner. Statistical analysis was performed using mixed-effects regression model analyses. RESULTS The mean total wear of posterior single crowns was -8.1 microm (+/-9.7 microm) in group 1, -7.0 microm (+/-9.1 microm) in group 2, and -3.4 microm (+/-6.3 microm) in the control group. Statistical analysis revealed wear behavior was significantly different from the control group for group 1 (p=0.014) and group 2 (p<0.01). No significant difference was detected between groups 1 and 2. Age, gender, and opposing teeth had no significant effect on wear behavior. CONCLUSIONS Within a 12-month observation period mean total wear of posterior polymer crowns with and without a glass-fiber framework was significantly greater than for metal-ceramic crowns. The selection of restorative materials should be based on knowledge of clinical wear in order to preserve occlusal stability.
Collapse
|
44
|
Dye staining gap test: an alternative method for assessing marginal gap formation in composite restorations. Acta Odontol Scand 2006; 64:141-5. [PMID: 16809190 DOI: 10.1080/00016350500474565] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate and compare marginal adaptation of composite restorations assessed by a dye staining method and by scanning electron microscopy (SEM) analysis. MATERIAL AND METHODS Twenty bovine incisors were selected and ground flat to expose dentin. Two cylindrical cavities were prepared on the central area of flattened surfaces. Single bond adhesive system was applied in accordance with the manufacturer's instructions and the cavities were filled with Filtek Z250 or Filtek Flow. The specimens were polished and replicas were obtained in epoxy resin. The replicas were observed by SEM for marginal quality/quantity evaluation. Caries detector was then applied on each specimen for 5 s to verify marginal adaptation through dye staining of the formed gaps on the outer margins. Images of the stained gaps were transferred to a computer measurement program to determine gap length. The length of the gap was expressed as the percentage of total length of the margins observed. Data were submitted to two-way ANOVA and Pearson correlation. RESULTS Filtek flow showed 36% and 34% and Filtek Z250 27% and 29% of gap in the margins when evaluated by SEM analysis and by the dye staining test, respectively. There was no difference between the composites, regardless of the evaluation technique. There was a strong positive correlation (r=0.83) between the results obtained with the tested methods to assess marginal gap. CONCLUSION Dye staining the gaps can be used with good reliability to evaluate the gap formation in composite restorations.
Collapse
|
45
|
Automated magnification calibration in transmission electron microscopy using Fourier analysis of replica images. Ultramicroscopy 2006; 106:255-60. [PMID: 16289852 DOI: 10.1016/j.ultramic.2005.08.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2005] [Revised: 08/08/2005] [Accepted: 08/30/2005] [Indexed: 11/15/2022]
Abstract
The magnification factor in transmission electron microscopy is not very precise, hampering for instance quantitative analysis of specimens. Calibration of the magnification is usually performed interactively using replica specimens, containing line or grating patterns with known spacing. In the present study, a procedure is described for automated magnification calibration using digital images of a line replica. This procedure is based on analysis of the power spectrum of Fourier transformed replica images, and is compared to interactive measurement in the same images. Images were used with magnification ranging from 1,000 x to 200,000 x. The automated procedure deviated on average 0.10% from interactive measurements. Especially for catalase replicas, the coefficient of variation of automated measurement was considerably smaller (average 0.28%) compared to that of interactive measurement (average 3.5%). In conclusion, calibration of the magnification in digital images from transmission electron microscopy may be performed automatically, using the procedure presented here, with high precision and accuracy.
Collapse
|
46
|
Abstract
OBJECTIVES The objective of this study was to examine the two-body wear resistance of nine different resin denture teeth and one experimental material. METHODS The two-body wear test was performed in a chewing simulator with an antagonistic Al(2)O(3) ball under an axial load of 40 N for 100,000 cycles. In each test series, an enamel sample was included as a reference. The wear was determined with an optical 3D surface profilometer. For statistical evaluation, SPSS for Windows was used. RESULTS The samples of Artiplus (18.7-SD 21.0) and e-Ha (21.2-SD 15.1) showed the lowest volumetric wear (in mm(3)x10(-3)) after 100,000 cycles. The difference from the other materials tested, except NC Veracia Posterior, was statistically significant (p=0.001-0.037). SR-Postaris-DCL (55.0-SD 6.8), SR-Orthosit-PE (61.1-SD 12.4) and Vitapan (72.1-SD 15.9) exhibited medium-sized wear values with low dispersion, whereas Orthognat (80.1-SD 31.6), Premium 8 (84.6-SD 31.4), NC Veracia Posterior (87.0-SD 52.7), SR-Orthotyp-PE (114.6-SD 28.0) and Trubyte Portrait (123.0-SD 45.6) showed high wear values with great variations. Statistically provable differences were found between SR-Orthotyp-PE and SR-Postaris-DCL (p=0.019) and also between SR-Orthotyp-PE and SR-Orthosit-PE (p=0.031). For enamel, a medium-sized wear value of 66.1-SD 76.8 was determined. SIGNIFICANCE The denture teeth examined showed differences in two-body wear resistance. The wear values determined were in some cases higher and in others lower than those of natural enamel. A definite connection between the wear resistance and the chemical composition of the materials could not be found in this investigation.
Collapse
|
47
|
Alzheimer paired helical filaments (PHFs) studied by high-resolution TEM: what can vertical Pt-C replication tell us about the organization of the pronase-digested PHF core? Microsc Res Tech 2006; 67:196-209. [PMID: 16103996 DOI: 10.1002/jemt.20198] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Untreated paired helical filaments (PHFs) and pronase-digested PHF-core filaments were stereoscopically imaged with a freeze-drying vertical platinum-carbon replication preparation method for TEM. The untreated PHF have an average wide region (W) = 22.8 +/- 2.4 nm, a narrow region (T) = 10.6 +/- 1.7 nm, and a helical turn period (L) = 78.6 +/- 13.4. The surfaces of the untreated PHF's fuzzy coat appears disorganized. The widths of the pronase-treated PHF-core filaments were significantly reduced (W(d) = 14.8 +/- 1.2 nm, T(d) = 5.7 +/- 1.0 nm, and L(d) = 75.4 +/- 17 nm). The surfaces of the untreated PHF contained approximately 1.1 nm strands, the same size as tau monomer ( approximately 1.0 nm). The pronase-digested PHF cores mostly contained approximately 1.6 +/- 0.3 nm strands although strand diameters ranged from 0.6-2.5 nm. The strands sometimes appear to be wrapped around the filament axis; less often, they appear to be roughly parallel to the PHF axis, and otherwise appear to be randomly oriented. Images of pronase-digested PHF core images are discussed in relation to the core's biochemical composition, its proposed beta structure, and structural subunit models. Images of the untreated and the pronase-digested PHF support a helical ribbon morphology.
Collapse
|
48
|
Comparative analysis of dental enamel polyvinylsiloxane impression and polyurethane casting methods for SEM research. Microsc Res Tech 2006; 69:246-52. [PMID: 16586485 DOI: 10.1002/jemt.20296] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Dental casting is a very common procedure for making high-quality replicas of paleo-anthropological remains. Replicas are frequently used, instead of original remains, to study both fossil and extant Primate teeth in morphological and metrical analyses. Several commercial products can be used in molds. This study analyzed SEM image resolution and enamel surface feature definition of tooth molds at various magnification levels and obtained, with both Coltène and 3M low-viscosity body polyvinylsiloxane impression, materials and polyurethane casts. Results, through comparison with the original teeth, show that both the negative molds and the positive casts are highly reliable in replicating enamel surfaces. However, positive cast quality is optimal for SEM observation only till the fourth consecutive replica from the original mold, especially at high SEM magnification levels.
Collapse
|
49
|
Abstract
This study tested the hypothesis that hybridization of intraradicular dentin eliminates interfacial gaps, thereby improving the coronal seal and retention of teeth restored with fiber posts. Post spaces were bonded with two types of fiber posts, using the corresponding etch-and-rinse adhesives and dual-cured resin cements. Longitudinal sections of the interfaces were examined for dentin hybridization in the coronal- and middle-thirds of the root canals. Resin replicas of these sections were evaluated for interfacial gap formation. Although intraradicular dentin hybridization was not compromised irrespective of whether the adhesives were light-cured before cementation, the universal occurrence of interfacial gaps along the hybrid layer surface or the post-cement interface reflects the challenge in bonding to post spaces with low compliance and high C-factors. The clinical success associated with bonded fiber posts is probably due predominantly to frictional retention.
Collapse
|
50
|
Molecular dynamics imaging in micropatterned living cells. Nat Methods 2005; 2:739-41. [PMID: 16179919 DOI: 10.1038/nmeth796] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2005] [Accepted: 08/26/2005] [Indexed: 11/09/2022]
Abstract
Micropatterning approaches using self-assembled monolayers of alkyl thiols on gold are not optimal for important imaging modalities in cell biology because of absorption of light and scattering of electrons by the gold layer. We report here an anisotropic solid microetching (ASOMIC) procedure that overcomes these limitations. The method allows molecular dynamics imaging by wide-field and total internal reflection fluorescence (TIRF) microscopy of living mammalian cells and correlative platinum replica electron microscopy.
Collapse
|