51
|
In-lab simulation of CAD/CAM grinding and intaglio surface treatments of 4YSZ monolithic restorations: Effect on its load-bearing capacity under fatigue. J Mech Behav Biomed Mater 2022; 134:105417. [PMID: 36049370 DOI: 10.1016/j.jmbbm.2022.105417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/09/2022] [Accepted: 08/11/2022] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To evaluate the effect of in-lab simulation of CAD/CAM grinding and intaglio surface treatments on the surface characteristics (topography and roughness) and fatigue behavior of adhesively luted 4YSZ simplified restorations. METHODS Ceramic discs (Ø = 10 mm, thickness = 1 mm) were randomly allocated into 6 groups considering: "In-lab simulation of CAD/CAM grinding" (ground or polished) and "intaglio surface treatments": Ctrl (without surface treatment), AlOx (aluminum oxide air abrasion) or GLZ (glaze spray application). The surface roughness of all samples was measured, the treated discs received a ceramic primer, were luted with resin cement onto a dentin analogue material (woven glass-reinforced epoxy resin) and tested under a cyclic fatigue test (step-stress approach, n = 15; 1.4 Hz, 10,000 cycles/step, step-size of 100N starting at 200N until failure). A complementary analysis was performed to corroborate the findings in the fatigue test that the glaze fill defects increase the mechanical properties of the ceramic. To do so, bars (n= 10; 1.0 × 1.0 × 12 mm; considering the groups: N-ID: non-indented; ID: indented; ID-GLZ: indented plus glaze spray application) were indented in a vickers hardness tester to produce a crack pattern, treated with glaze or not, and then submitted to flexural strength tests (FS). Fractographic and topographic analysis were performed. RESULTS In-lab simulation of CAD/CAM grinding decreased the fatigue failure load of the 4YSZ ceramic when comparing polished and ground groups, regardless of surface treatment. GLZ induced better fatigue performance compared to the air abrasion, regardless of the grinding condition (ground or polished surface). The results of the flexural strength test corroborated the findings in the fatigue test, as the ID-GLZ group presented superior FS than the ID group, however both had inferior FS than N-ID. There is an inverse association between roughness and fatigue failure load, as the higher the surface roughness, the lower the fatigue failure load. Failures in the fatigue and flexural strength tests started from the face subjected to tensile stresses. CONCLUSION In-lab simulation of CAD/CAM grinding had a detrimental effect on the fatigue behavior of 4YSZ and glaze spray induced better 4YSZ performance compared to the air abrasion. The intaglio surface treatments differently influenced the 4YSZ fatigue performance, however, only glaze spray can reverse the damage caused by the grinding.
Collapse
|
52
|
Guilardi LF, Pereira G, Giordani JC, Kleverlaan CJ, Valandro LF, Rippe MP. Cement Choice and the Fatigue Performance of Monolithic Zirconia Restorations. Oper Dent 2022; 47:461-472. [PMID: 35917240 DOI: 10.2341/20-143-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/21/2021] [Indexed: 11/23/2022]
Abstract
This study investigated the fatigue failure load of simplified monolithic yttria partially stabilized zirconia polycrystal restorations cemented to a dentin-like substrate using different luting systems. Disc-shaped ceramic (Zenostar T, 10 mm Ø × 0.7 mm thick) and dentin-like substrate (10 mm Ø × 2.8 mm thick) were produced and randomly allocated into eight groups, without or with thermocycling (TC=5-55°C/12,000×): "cement" (RelyX Luting 2 - glass ionomer cement [Ion], [Ion/TC]; RelyX U200 - self-adhesive resin cement [Self], [Self/TC]; Single Bond Universal+RelyX Ultimate - MDP-containing adhesive + resin cement [MDPAD + RC], [MDP-AD + RC/TC]; ED Primer II+Panavia F 2.0 - Primer + MDP-containing resin cement [PR + MDP-RC], [PR + MDP-RC/TC])). Each luting system was used as recommended by the manufacturer. Staircase methodology (20 Hz; 250,000 cycles) was applied for obtaining the fatigue failure loads. Fractographic characteristics were also assessed. At baseline, the Ion group presented the lowest fatigue load, although it was statistically similar to the Self group. The resin-based cement systems presented the highest fatigue performance, with the Ion group being only statistically equal to the Self group. Thermocycling influenced the groups differently. After aging, the MDP-AD + RC presented the highest mean, followed by the PR + MDP-RC and Self groups, while the Ion group had the lowest mean. Fractographic analysis depicted all failures as radial cracks starting at the zirconia intaglio surface. The luting system with MDP-containing adhesive applied prior to the resin cement presented the highest fatigue failure load after aging, presenting the best predictability of stable performance. Despite this, monolithic zirconia presents high load-bearing capability regardless of the luting agent.
Collapse
Affiliation(s)
- L F Guilardi
- Luis Felipe Guilardi, associate researcher, Post-Graduate Program in Oral Science (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - Gkr Pereira
- Gabriel Kalil Rocha Pereira, MsciD, PhD, adjunct professor, Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - J C Giordani
- João Carlos Giordani, undergraduate student, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - C J Kleverlaan
- Cornelis Johannes Kleverlaan, PhD, full professor, Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam, Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Noord-Holland, The Netherlands
| | - L F Valandro
- Luiz Felipe Valandro, MSciD, PhD, full professor, Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - M P Rippe
- *Marilia Pivetta Rippe, MSciD, PhD, adjunct professor, Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| |
Collapse
|
53
|
Mayinger F, Buser R, Laier M, Schönhoff LM, Kelch M, Hampe R, Stawarczyk B. Impact of the material and sintering protocol, layer thickness, and thermomechanical aging on the two-body wear and fracture load of 4Y-TZP crowns. Clin Oral Investig 2022; 26:6617-6628. [PMID: 35840737 DOI: 10.1007/s00784-022-04616-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 07/04/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVES The aim of this study is to investigate the influence of the material and corresponding sintering protocol, layer thickness, and aging on the two-body wear (2BW) and fracture load (FL) of 4Y-TZP crowns. MATERIALS AND METHODS Multi-layer 4Y-TZP crowns in three thicknesses (0.5 mm/1.0 mm/1.5 mm) were sintered by high-speed (Zolid RS) or conventional (Zolid Gen-X) sintering. 2BW of ceramic and enamel antagonist after aging (1,200,000 mechanical-, 6000 thermal-cycles) was determined by 3D-scanning before and after aging and subsequent matching to determine volume and height loss (6 subgroups, n = 16/subgroup). FL was examined initially and after aging (12 subgroups, n = 16/subgroup). Fractographic analyses were performed using light-microscope imaging. Global univariate analysis of variance, one-way ANOVA, linear regression, Spearman's correlation, Kolgomorov-Smirnov, Mann-Whitney U, and t test were computed (alpha = 0.05). Weibull moduli were determined. Fracture types were analyzed using Ciba Geigy table. RESULTS Material/sintering protocol did not influence 2BW (crowns: p = 0.908, antagonists: p = 0.059). High-speed sintered Zolid RS presented similar (p = 0.325-0.633) or reduced (p < 0.001-0.047) FL as Zolid Gen-X. Both 4Y-TZPs showed an increased FL with an increasing thickness (0.5(797.3-1429 N) < 1.0(2087-2634 N) < 1.5(2683-3715 N)mm; p < 0.001). For most groups, aging negatively impacted FL (p < 0.001-0.002). Five 0.5 mm specimens fractured, four showed cracks during and after aging. CONCLUSIONS High-speed sintered crowns with a minimum thickness of 1.0 mm showed sufficient mechanical properties to withstand masticatory forces, even after a simulated aging period of 5 years. CLINICAL RELEVANCE Despite the manufacturer indicating a thickness of 0.5 mm to be suitable for single crowns, a minimum thickness of 1.0 mm should be used to ensure long-term satisfactory results.
Collapse
Affiliation(s)
- Felicitas Mayinger
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany.
| | - Ramona Buser
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany.,Department of Reconstructive Dentistry and Gerodontology, University of Bern, Freiburgstrasse 7, 3007, Bern, Switzerland
| | - Maximilian Laier
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Lisa Marie Schönhoff
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Matthias Kelch
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Rüdiger Hampe
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, Dental School, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| |
Collapse
|
54
|
Baldi A, Carossa M, Comba A, Alovisi M, Femiano F, Pasqualini D, Berutti E, Scotti N. Wear Behaviour of Polymer-Infiltrated Network Ceramics, Lithium Disilicate and Cubic Zirconia against Enamel in a Bruxism-Simulated Scenario. Biomedicines 2022; 10:biomedicines10071682. [PMID: 35884986 PMCID: PMC9313215 DOI: 10.3390/biomedicines10071682] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 07/08/2022] [Accepted: 07/11/2022] [Indexed: 11/16/2022] Open
Abstract
The present study aimed to evaluate the wear rate of polymer-infiltrated network composites and ceramics against enamel in a bruxism-simulated scenario. Ninety-six (n = 96) molars were divided into six groups (n = 16) according to their occlusal material: group 1—a polymer-infiltrated network ceramic (PINC); group 2—a second polymer-infiltrated network ceramic (PINC2); group 3—nanohybrid resin-based composite (CO); group 4—cubic zirconia (ZR); group 5—lithium disilicate (LS); and group 6—sound enamel (EN). A laser scanner was used to digitalize all of the occlusal surfaces before and after a fatigue test, which was conducted with a chewing simulator set at 80 N and semicircular movement in order to simulate bruxist movement and loads. Statistical analysis of volume loss was performed with a one-way ANOVA and post hoc Bonferroni test. ZR had significantly inferior wear to PINC (p ≤ 0.01) and CO (p = 0.04). LS wore the antagonist enamel significantly more than PINC, CO, PINC2 and EN (p ≤ 0.01). On the other hand, ZR wore the antagonist enamel significantly more than CO (p ≤ 0.01) and PINC2 (p = 0.05). In conclusion, PINCs better preserved antagonist enamel at the expense of a higher wear of their own. LS causes significantly higher enamel wear compared with PINCs. ZR caused significantly higher enamel wear compared with CO and PINC2, but it was wear-resistant.
Collapse
Affiliation(s)
- Andrea Baldi
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| | - Massimo Carossa
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
- Correspondence:
| | - Allegra Comba
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| | - Mario Alovisi
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| | - Felice Femiano
- Restorative Dentistry, Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Study of Campania, “Luigi Vanvitelli”, Via De Crecchio 6, 83138 Naples, Italy;
| | - Damiano Pasqualini
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| | - Elio Berutti
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| | - Nicola Scotti
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (A.B.); (A.C.); (M.A.); (D.P.); (E.B.); (N.S.)
| |
Collapse
|
55
|
Ma Q, Ding Q, Zhang L, Sun Y, Xie Q. Surface characteristics and flexural strength of Porous-Surface designed zirconia manufactured via stereolithography. J Prosthodont 2022; 32:e81-e89. [PMID: 35778958 DOI: 10.1111/jopr.13565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 06/17/2022] [Indexed: 12/01/2022] Open
Abstract
PURPOSE To design and fabricate zirconia bars with porous surfaces using stereolithography and evaluate their surface characteristics and flexural strengths. METHODS Five groups of zirconia bars (20 mm × 4 mm × 2 mm) with interconnected porous surfaces were designed and manufactured: (i) 400-μm pore size and 50% porosity (D400-P50 group), (ii) 400-μm pore size and 30% porosity (D400-P30 group), (iii) 200-μm pore size and 50% porosity (D200-P50 group), (iv) 200-μm pore size and 30% porosity (D200-P30 group), and (v) 100-μm pore size and 30% porosity (D100-P30 group). Zirconia bars without a porous surface (NP) were used as controls. The surface topographies and pore structures were investigated using scanning electron microscopy and three-dimensional laser microscopy. The printed porosity was calculated using the Archimedes method. Fifteen specimens from each group were subjected to a three-point bending test according to the ISO 6872:2015 standard. A Weibull analysis was performed, and the fractured surfaces were examined using scanning electron microscopy. RESULTS Zirconia bars with porous surfaces were designed and successfully manufactured. The designed pore size, porosity, and shape of the printed pores were approximately achieved for all the porous surfaces. The flexural strength of the control group was significantly higher than those of the groups with porous surfaces (p < 0.001). For the same porosity, groups with a pore size of 400 μm exhibited a lower flexural strength than the other groups (p<0.001). Additionally, for the same pore-size design, the flexural strengths of group D400-P50 and D400-P30 exhibited no significant differences (p = 0.150), while the flexural strengths of D200-P30 were significantly higher than that of D200-P50 group (p = 0.043). The control group and D400-P50 group had higher Weibull moduli than the other groups. The fractography of the specimens with porous surfaces indicated more than one crack origin, mainly owing to defects, including pores and cracks. CONCLUSION Zirconia bars with porous surfaces were successfully designed and fabricated using the stereolithography technique. Although porous surfaces may be advantageous for osteogenesis, the porous-surface design can reduce the flexural strength of the printed zirconia bars. By reducing the pore size, controlling the porosity, and improving the printing accuracy, a higher strength can be achieved. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Quanquan Ma
- Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, China
| | - Qian Ding
- Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, China.,Foshan (Southern China) Institute for New Materials, Guangdong, China
| | - Lei Zhang
- Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, China
| | - Yuchun Sun
- Center of Digital Dentistry, Peking University School and Hospital of Stomatology, Beijing, China.,National Engineering Laboratory for Digital and Material Technology of Stomatology, Research Center of Engineering and Technology for Digital Dentistry, Beijing, China
| | - Qiufei Xie
- Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, China
| |
Collapse
|
56
|
Ordoñez Balladares A, Abad-Coronel C, Ramos JC, Martín Biedma BJ. Fracture Resistance of Sintered Monolithic Zirconia Dioxide in Different Thermal Units. MATERIALS 2022; 15:ma15072478. [PMID: 35407810 PMCID: PMC8999687 DOI: 10.3390/ma15072478] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 03/16/2022] [Accepted: 03/22/2022] [Indexed: 01/27/2023]
Abstract
The purpose of this study was to compare the fracture strength of monolithic zirconium dioxide subjected to a sintering process in two different furnaces: InFire HTC Speed and CEREC SpeedFire. Methods: Forty restorations were designed and machined using a computer aided design / computer aidded machine (CAD/CAM) system. The restorations were randomly assigned to two groups of 20 samples each, Group 1 for the SpeedFire furnace (fast sintering) and Group 2 for the InFire furnace (slow sintering). Each of the crowns was subjected to a maximum compression load recorded in Newtons (N) and a displacement control with a speed of 1 mm/min. Results: Group 1 presented an average of 1222.8 N and a standard deviation of 136.91 N. Group 2 obtained a mean of 1068.5 N and a standard deviation of 316.39 N. Conclusions: There were no significant differences between the two groups, and the mechanical strength of the material was not affected, which would imply a saving of clinical and laboratory time when performing rapid sintering on monolithic translucent zirconium dioxide restorations. However, rapidly sintered restorations have limited reliability.
Collapse
Affiliation(s)
- Andrea Ordoñez Balladares
- Faculty of Dentistry, Universidad de Guayaquil, Guayaquil 090514, Ecuador;
- Faculty of Dentistry, Universidad de Santiago de Compostela, 15782 Galicia, Spain;
| | - Cristian Abad-Coronel
- Department of Digital Dentistry and CAD/CAM Materials, Faculty of Dentistry, Universidad de Cuenca, Cuenca 010107, Ecuador
- Faculty of Dentistry, Universidad San Francisco de Quito, Quito 170901, Ecuador
- Correspondence:
| | - Joao Carlos Ramos
- Faculty of Medicine, Universidad de Coimbra, 3000-370 Coimbra, Portugal;
| | | |
Collapse
|
57
|
Sailer I, Karasan D, Todorovic A, Ligoutsikou M, Pjetursson BE. Prosthetic failures in dental implant therapy. Periodontol 2000 2022; 88:130-144. [PMID: 35103329 PMCID: PMC9305548 DOI: 10.1111/prd.12416] [Citation(s) in RCA: 96] [Impact Index Per Article: 32.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Both fixed and removable implant-supported prostheses are well-established methods for replacing missing teeth in partially or fully edentulous patients. Numerous systematic reviews have been performed in recent years to evaluate the survival and complication rates of implant-retained fixed dental prostheses and implant-retained overdentures, displaying high 5-year survival rates ranging from 97.1% for fixed dental prostheses to 95%-100% for implant-retained overdentures. However, the survival rates only represent the prostheses remaining in use for a defined follow-up time, and do not account for the potential prosthetic complications that may have arisen and influence the general success of the implant treatment. The most common technical complications of fixed implant-retained single crowns are crown fracture, fractures of ceramic implant abutments, and esthetic problems. The predominant technical complication at multiple-unit, implant-retained fixed dental prostheses is fracture/chipping of the veneering ceramic. Reported technical complications for implant-retained overdentures are overdenture fracture or chipping of the veneer materials, whereas mechanical complications include implant fracture, attachment failure, and attachment housing or insert complications. To reduce the risk of such failures, a comprehensive pretreatment diagnostic work-up is essential, including defining the prosthetic goal with the aid of a wax-up or set-up and the associated ideal, prosthetically oriented three-dimensional implant position. Furthermore, selection of the ideal type of prosthesis, including the respective implant components and materials, is important for clinical long-term treatment success.
Collapse
Affiliation(s)
- Irena Sailer
- Division of Fixed Prosthodontics and BiomaterialsUniversity Clinics for Dental MedicineUniversity of GenevaGenevaSwitzerland
| | - Duygu Karasan
- Division of Fixed Prosthodontics and BiomaterialsUniversity Clinics for Dental MedicineUniversity of GenevaGenevaSwitzerland
| | - Ana Todorovic
- Division of Fixed Prosthodontics and BiomaterialsUniversity Clinics for Dental MedicineUniversity of GenevaGenevaSwitzerland
- Division of ProsthodonticsFaculty of Dental MedicineUniversity of BelgradeBelgradeSerbia
| | - Maria Ligoutsikou
- Division of Fixed Prosthodontics and BiomaterialsUniversity Clinics for Dental MedicineUniversity of GenevaGenevaSwitzerland
| | - Bjarni Elvar Pjetursson
- Division of Fixed Prosthodontics and BiomaterialsUniversity Clinics for Dental MedicineUniversity of GenevaGenevaSwitzerland
- Department of Reconstructive DentistryFaculty of OdontologyUniversity of IcelandReykjavikIceland
| |
Collapse
|
58
|
Velho HC, Dapieve KS, Valandro LF, Pereira GKR, Venturini AB. Cyclic fatigue tests on non-anatomic specimens of dental ceramic materials: A scoping review. J Mech Behav Biomed Mater 2022; 126:104985. [PMID: 34861521 DOI: 10.1016/j.jmbbm.2021.104985] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 11/15/2021] [Accepted: 11/18/2021] [Indexed: 11/16/2022]
Abstract
The aim of the present scoping review was to identify and discuss the methods, testing parameters, and characteristics used to induce cyclic fatigue on non-anatomic dental ceramic specimens. In vitro studies written in English which evaluated commercially-available non-anatomic dental ceramic specimens subjected to mechanical cyclic fatigue were selected. The search was performed in the PubMed, Scopus and Web of Science databases. The initial search yielded 1,636 articles, of which 81 were included. Based on the collected data, most of the included studies evaluated dental ceramic specimens cemented to supporting substrate (n= 42; 51.9%); used step-stress (n= 35; 42.2%) accelerated fatigue test, loading frequencies above 10 Hz (n= 31, 35.6%), stainless steel (n = 28, 32.6%) load applicator with spherical shaped tip 40 mm diameter (n= 25, 30.9%); applied only axial loads (n= 77, 95.1%); and considered a wet testing environment (n= 65, 78.3%). The definition of test geometry, method, and testing parameters must be cautiously considered according to the study objective and the scenario that is simulated. Accelerated fatigue tests, load frequencies up to 20 Hz, a 40 mm stainless steel spherical load applicator and a wet testing environment are the major common defined parameters presented in the existing literature. More studies exploring the influence of such factors on fatigue mechanism are necessary.
Collapse
Affiliation(s)
- Helder Callegaro Velho
- MSciD and PhD Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| | - Kiara Serafini Dapieve
- MSciD and PhD Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| | - Luiz Felipe Valandro
- MSciD and PhD Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| | - Andressa Borin Venturini
- MSciD and PhD Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| |
Collapse
|
59
|
Molnár J, Fráter M, Sáry T, Braunitzer G, Vallittu PK, Lassila L, Garoushi S. Fatigue performance of endodontically treated molars restored with different dentin replacement materials. Dent Mater 2022; 38:e83-e93. [DOI: 10.1016/j.dental.2022.02.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 01/06/2022] [Accepted: 02/19/2022] [Indexed: 01/08/2023]
|
60
|
Garófalo SA, Wehner M, Dohrn A, Bilandžić MD, Roos C, Wierichs RJ, Meyer-Lueckel H, Aranha ACC, Esteves-Oliveira M. Increasing dental zirconia micro-retentive aspect through ultra-short pulsed laser microstructuring: study on flexural strength and crystal phase characterization. Clin Oral Investig 2022; 26:939-955. [PMID: 34402980 PMCID: PMC8791917 DOI: 10.1007/s00784-021-04077-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Accepted: 07/10/2021] [Indexed: 11/13/2022]
Abstract
OBJECTIVES Although ultra-short pulsed laser (USPL) microstructuring has previously improved zirconia bond-strength, it is yet unclear how different laser-machined surface microstructures and patterns may influence the material's mechanical properties. Therefore, the aim of this study was to assess the flexural strength of zirconia after different USPL settings creating three different geometrical patterns with structures in micrometer scale. METHODS One hundred sixty zirconia bars (3Y-TZP, 21 × 4 × 2.1 mm) were prepared and randomly divided into five groups (n = 32): no surface treatment (negative control-NC); sandblasting with Al2O3 (SB); and three laser groups irradiated with USPL (Nd:YVO4/1064 nm/2-34 J/cm2/12 ps): crossed-lines (LC), random-hatching (LR), and parallel-waves (LW). Bars were subjected to a four-point flexural test (1 mm/min) and crystal phase content changes were identified by X-ray diffraction. Surface roughness and topography were analyzed through 3D-laser-profilometry and SEM. Data were analyzed with parametric tests for roughness and Weibull for flexural strength (α = 5%). RESULTS LR (Mean[95%CI]: 852.0 MPa, [809.2-894.7]) was the only group that did not show a significantly different flexural strength than NC (819.8 MPa, [796.6-842.9]), (p > 0.05). All laser groups exhibited higher Weibull moduli than NC and SB, indicating higher reliability and homogeneity of the strength data. An increase of monoclinic phase peak was only observed for SB. CONCLUSION In conclusion, USPL created predictable, homogeneous, highly reproducible, and accurate surface microstructures on zirconia ceramic. The laser-settings of random-hatching (12 ps pulses) increased 3Y-TZP average surface roughness similarly to SB, while not causing deleterious crystal phase transformation or loss of flexural strength of the material. Furthermore, it has increased the Weibull modulus and consequently material's reliability. CLINICAL SIGNIFICANCE Picosecond laser microstructuring (LR conditions) of 3Y-TZP ceramic does not decrease its flexural strength, while increasing materials realiability and creating highly reproducible and accurate microstructures. These features may be of interest both for improving clinical survival of zirconia restorations as well as enhancing longevity of zirconia implants.
Collapse
Affiliation(s)
| | - Martin Wehner
- Fraunhofer Institute for Laser Technology (ILT), RWTH Aachen University, Aachen, Germany
| | - Andreas Dohrn
- Fraunhofer Institute for Laser Technology (ILT), RWTH Aachen University, Aachen, Germany
| | | | - Christian Roos
- Institute of Mineral Engineering (GHI), RWTH Aachen University, Aachen, Germany
| | - Richard Johannes Wierichs
- Department of Restorative, Preventive and Pediatric Dentistry, Zmk Bern, University of Bern, Bern, Switzerland
| | - Hendrik Meyer-Lueckel
- Department of Restorative, Preventive and Pediatric Dentistry, Zmk Bern, University of Bern, Bern, Switzerland
| | - Ana Cecilia Corrêa Aranha
- Special Laboratory of Lasers (LELO), Department of Restorative Dentistry, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Marcella Esteves-Oliveira
- Department of Restorative, Preventive and Pediatric Dentistry, Zmk Bern, University of Bern, Bern, Switzerland.
- Department of Cariology, Endodontology and Periodontology, University of Leipzig, Leipzig, Germany.
| |
Collapse
|
61
|
AlMutairi R, AlNahedh H, Maawadh A, Elhejazi A. Effects of Different Air Particle Abrasion Protocols on the Biaxial Flexural Strength and Fractography of High/Ultra-Translucent Zirconia. MATERIALS (BASEL, SWITZERLAND) 2021; 15:244. [PMID: 35009388 PMCID: PMC8745783 DOI: 10.3390/ma15010244] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/22/2021] [Accepted: 12/28/2021] [Indexed: 06/14/2023]
Abstract
In this study, the biaxial flexural strength (BFS) and fractography of high/ultra-translucent monolithic zirconia ceramics subjected to different mechanical surface pretreatments were evaluated. A total of 108 disc-shaped samples (12 mm diameter, 1.2 mm thickness) of three zirconia materials (5Y-ZP KATANA Zirconia UTML (ML), 3Y-TZP DD Bio ZX2 (DB), and 5Y-ZP DD cube X2 (DC)) were used. The BFS was investigated after subjecting the samples to surface treatment using air abrasion particles of two types (aluminum oxide or glass microbeads). The data were analyzed using two-way analysis of variance, followed by Scheffe's post hoc test for multiple comparisons. The mean ± standard deviation BFS for DB was highest after treatment with 50 µm Al2O3 (1626.05 ± 31.9 MPa), with lower values being observed following treatment with 50 µm glass microbeads (1399.53 ± 24.2 MPa) and in the control sample (1198.51 ± 21.1 MPa). The mean ± standard deviation (SD) BFSs for DC and ML were the highest in the control groups. Surface air abrasion with 50 µm Al2O3 particles and 2 bar pressure is recommended for 3Y-TZP translucent zirconia, while no abrasion of 5Y-ZP translucent zirconia ceramic.
Collapse
|
62
|
Relationships between fracture toughness, Y2O3 fraction and phases content in modern dental Yttria-doped zirconias. Ann Ital Chir 2021. [DOI: 10.1016/j.jeurceramsoc.2021.08.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
63
|
Fraga S, Pereira GKR, Guilardi LF, May LG, Valandro LF, Kleverlaan CJ. Influence of testing environment on static fatigue behavior of a glass and a polycrystalline ceramic. Braz Dent J 2021; 32:56-64. [PMID: 34755790 DOI: 10.1590/0103-6440202103961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 01/19/2021] [Indexed: 11/22/2022] Open
Abstract
It aims on evaluate the effect of the test environment on static fatigue behavior of lithium disilicate-based (LD), and yttrium oxide-stabilized zirconia (YSZ) ceramics. Specimens of LD (IPS e.max CAD, Ivoclar Vivadent) and YSZ (IPS e.max ZirCAD MO, 3 mol% Y2O3, Ivoclar Vivadent) were randomly allocated into three groups: tested in air, inert (paraffin oil, Sigma Aldrich) or distilled water. The static fatigue test (n=15) was performed using a piston-on-three ball assembly, adapted from ISO 6872, as follows: starting load 100 N for LD and 300 N for YSZ; loading application time set to 1 hour for each loading step; step size of 50 N for LD and 100 N for YSZ, applied successively until fracture. Data from static fatigue strength (MPa) and time to fracture (hours) were recorded. Fractographic analysis was executed. Survival analysis corroborates absence of influence of environment on static fatigue outcomes (fatigue strength, time to fracture and survival rates) for YSZ. For LD, specimens tested in air presented statistically superior survival rate and static fatigue strength (p= 0.025). In regards of time to fracture, LD tested in air were superior than when tested in distilled water (p=0.019) or inert (p=0.017) environments. No statistical differences for Weibull modulus were observed. Failures started on the tensile stress surface. Thus, the test environment did not affect slow crack growth (SCG) mechanisms during static fatigue test of YSZ ceramics, but it plays a significant role for the static fatigue behavior of lithium disilicate-based glass ceramics, indicating a high susceptibility to SCG.
Collapse
Affiliation(s)
- Sara Fraga
- Federal University of Rio Grande do Sul, Faculty of Dentistry, Department of Conservative Dentistry, Porto Alegre, RS, Brazil.
| | - Gabriel Kalil Rocha Pereira
- Federal University of Santa Maria, Faculty of Dentistry, Department of Restorative Dentistry, Santa Maria, RS, Brazil.
| | - Luís Felipe Guilardi
- Federal University of Santa Maria, Faculty of Dentistry, Department of Restorative Dentistry, Santa Maria, RS, Brazil.
| | - Liliana Gressler May
- Federal University of Santa Maria, Faculty of Dentistry, Department of Restorative Dentistry, Santa Maria, RS, Brazil.
| | - Luiz Felipe Valandro
- * Federal University of Santa Maria, Faculty of Dentistry, Department of Restorative Dentistry, Santa Maria, RS, Brazil.
| | - Cornelis Johannes Kleverlaan
- Academic Centre for Dentistry Amsterdam - ACTA, Department of Dental Materials Science, Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands.
| |
Collapse
|
64
|
Shelar P, Abdolvand H, Butler S. On the behaviour of zirconia-based dental materials: A review. J Mech Behav Biomed Mater 2021; 124:104861. [PMID: 34600431 DOI: 10.1016/j.jmbbm.2021.104861] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 09/23/2021] [Accepted: 09/24/2021] [Indexed: 11/28/2022]
Abstract
Zirconia-based dental materials are extensively used in clinical practice due to their tooth-like appearance, biofunctionality, biocompatibility, and affordability. However, premature clinical failures of veneering porcelains raise a concern about their integrity. Extensive studies have been performed over a decade to resolve this issue, but it is challenging to reference all information effectively. A single source identifying the significance of potential parameters on material performance has not previously been available. An evidence-based meta-narrative review technique was used to review the characteristic parameters that can affect the overall behaviour of zirconia-based materials. Keywords were chosen to assess manuscripts based on scientific coherence with this paper's research objective. Online keyword searches were carried out on ScienceDirect, PubMed, and SAGE databases for relevant published manuscripts from year 1985-2020.261 out of 3170 identified manuscripts were included. A total of 10 parameters were identified and classified into the material, manufacturing, and geometric aspects. The effect of every parameter was reviewed on the performance of the material. A discrepancy in findings was observed and is attributed to the fact that there is no standard methodology. This review acts as a single source that summarizes various parameters' contribution to zirconia-based dental materials' performance. This review facilitates manufacturing improvements by accounting for every parameter's effect on overall performance.
Collapse
Affiliation(s)
- Prashant Shelar
- Department of Mechanical & Materials Engineering, Western University, London, Ontario, Canada
| | - Hamidreza Abdolvand
- Department of Mechanical & Materials Engineering, Western University, London, Ontario, Canada
| | - Sheila Butler
- Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada.
| |
Collapse
|
65
|
Rodrigues CS, Dhital S, Kim J, May LG, Wolff MS, Zhang Y. Residual stresses explaining clinical fractures of bilayer zirconia and lithium disilicate crowns: A VFEM study. Dent Mater 2021; 37:1655-1666. [PMID: 34481666 DOI: 10.1016/j.dental.2021.08.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 08/24/2021] [Accepted: 08/25/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To understand the stress development in porcelain-veneered zirconia (PVZ) and porcelain-veneered lithium disilicate (PVLD) crowns with different veneer/core thickness ratios and cooling rates. To provide design guidelines for better performing bilayer restorations with the aid of Viscoelastic Finite Element Method (VFEM). METHODS The VFEM was validated by comparing the predicted residual stresses with experimental measurements. Then, the model was used to predict transient and residual stresses in the two bilayer systems. Models with two different veneer/core thickness ratios were prepared (2:1 and 1:1) and two cooling protocols were simulated (Fast: ∼300 °C/min, Slow: ∼30 °C/min) using the heat transfer module, followed by stress analysis in ABAQUS. The physical properties of zirconia, lithium disilicate, and the porcelains used for the simulations were determined as a function of temperature. RESULTS PVLD showed lower residual stresses than PVZ. The maximum tensile stresses in PVZ were observed in the cusp area, whereas those in PVLD were located in the central fossa. The 1:1 thickness ratio decreased stresses in both layers of PVZ. Slow cooling slightly decreased residual stresses in both systems. However, the cooling rate effect was more evident in transient stresses. SIGNIFICANCE Slow cooling is preferable for both systems. A thinner porcelain layer over zirconia lowers stresses throughout the restoration. The different stress distributions between PVZ and PVLD may affect their failure modes. Smaller mismatches in modulus, CTE, and specific heat between the constituents, and the use of low Tg porcelains can effectively reduce the deleterious transient and residual tensile stresses in bilayer restorations.
Collapse
Affiliation(s)
- Camila S Rodrigues
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University, 777 Eng. Francisco José Longo Av, 12245-000, São José dos Campos, SP, Brazil
| | - Sukirti Dhital
- Department of Civil and Environmental Engineering, University of Connecticut, 261 Glenbrook Rd., U-3037, Storrs, CT 06269, USA
| | - Jeongho Kim
- Department of Civil and Environmental Engineering, University of Connecticut, 261 Glenbrook Rd., U-3037, Storrs, CT 06269, USA
| | - Liliana Gressler May
- Department of Restorative Dentistry, School of Dentistry, Federal University of Santa Maria, 1000 Roraima Av., T Street, Building 26F, 97105-900, Santa Maria, RS, Brazil
| | - Mark S Wolff
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, 240 S. 40th Street, Philadelphia, PA 19104, USA
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, 240 S. 40th Street, Philadelphia, PA 19104, USA.
| |
Collapse
|
66
|
Grzebieluch W, Kowalewski P, Grygier D, Rutkowska-Gorczyca M, Kozakiewicz M, Jurczyszyn K. Printable and Machinable Dental Restorative Composites for CAD/CAM Application-Comparison of Mechanical Properties, Fractographic, Texture and Fractal Dimension Analysis. MATERIALS 2021; 14:ma14174919. [PMID: 34501009 PMCID: PMC8434230 DOI: 10.3390/ma14174919] [Citation(s) in RCA: 64] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 08/20/2021] [Accepted: 08/26/2021] [Indexed: 12/12/2022]
Abstract
Thanks to the continuous development of light-curing resin composites it is now possible to print permanent single-tooth restorations. The purpose of this study was to compare resin composites for milling -Gandio Blocks (GR), Brilliant Crios (CR) and Enamic (EN) with resin composite for 3D printing-Varseo Smile Crown plus (VSC). Three-point bending was used to measure flexural strength (σf) and flexural modulus (Ef). The microhardness was measured using a Vickers method, while fractographic, microstructural, texture and fractal dimension (FD) analyses were performed using SEM, optical microscope and picture analysis methods. The values of σf ranged from 118.96 (±2.81) MPa for EN to 186.02 (±10.49) MPa for GR, and the values of Ef ranged from 4.37 (±0.8) GPa for VSC to 28.55 (±0.34) GPa for EN. HV01 ranged from 25.8 (±0.7) for VSC to 273.42 (±27.11) for EN. The filler content ranged from 19-24 vol. % for VSC to 70-80 vol. % for GR and EN. The observed fractures are typical for brittle materials. The correlation between FD of materials microstructure and Ef was observed. σf of the printed resin depends on layers orientation and is significantly lower than σf of GR and CR. Ef of the printed material is significantly lower than Ef of blocks for milling.
Collapse
Affiliation(s)
- Wojciech Grzebieluch
- Laboratory for Digital Dentistry, Department of Conservative Dentistry Witch Endodontics, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland
- Correspondence: ; Tel.: +48-71-784-03-61
| | - Piotr Kowalewski
- Department of Fundamentals of Machine Design and Mechatronic Systems, Wroclaw University of Science and Technology, Lukasiewicza 7/9, 50-371 Wroclaw, Poland;
| | - Dominika Grygier
- Department of Vehicle Engineering, Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, Lukasiewicza 5, 50-371 Wroclaw, Poland; (D.G.); (M.R.-G.)
| | - Małgorzata Rutkowska-Gorczyca
- Department of Vehicle Engineering, Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, Lukasiewicza 5, 50-371 Wroclaw, Poland; (D.G.); (M.R.-G.)
| | - Marcin Kozakiewicz
- Department of Maxillofacial Surgery, Medical University of Lodz, 113 S. Zeromski Street, 90-549 Lodz, Poland;
| | - Kamil Jurczyszyn
- Department of Oral Surgery, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland;
| |
Collapse
|
67
|
Alberto Jurado C, Kaleinikova Z, Tsujimoto A, Alberto Cortés Treviño D, Seghi RR, Lee DJ. Comparison of Fracture Resistance for Chairside CAD/CAM Lithium Disilicate Crowns and Overlays with Different Designs. J Prosthodont 2021; 31:341-347. [PMID: 34297866 DOI: 10.1111/jopr.13411] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/21/2021] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To determine the fracture resistance of chairside computer-aided design and computer-assisted manufacturing (CAD/CAM) lithium disilicate full coverage crowns and two different designs of overlay restorations for premolars. MATERIALS AND METHODS CAD/CAM lithium disilicate (IPS e.max CAD for CEREC/HT A1 C14, Ivoclar Vivadent) restorations (15 specimens/group) with 1.5 mm occlusal thickness and 1.0 mm chamfer were designed and fabricated with a chairside CAD/CAM system (CEREC, Dentsply Sirona). The restorations were prepared in three different designs: (1) full coverage crowns, (2) overlays with the margin located 2 mm above the gingiva, and (3) overlays with the margin located 4 mm above the gingiva. Restorations were cemented using conventional resin luting cement (Multilink, Ivoclar Vivadent) with primer system (Monobond Plus, Ivoclar Vivadent) to resin printed dies, load cycled (2,000,000 load cycles at 1 Hz with 275 N force), and then finally loaded with a steel indenter until failure. Scanning electron microscopy observations of fractured surfaces were also conducted. Group results were analyzed with one-way analysis of variance, and the medians were evaluated independently with Kruskal-Wallis. RESULTS The fracture force of CAD/CAM lithium disilicate restorations was significantly different (p < 0.001) depending on the design of the restoration. Full coverage crowns showed significantly higher force to fracture (1018.8 N) than both types of overlays (p = 0.002 for overlay 2.0 mm and p < 0.001 for overlay 4.0 mm above gingiva). Among the two overlays, the restoration with the margin located 2 mm above the gingiva showed significantly higher fracture force (813.8 N) than the overlay with margin at 4 mm above the gingiva (436.1 N; p < 0.001). The fracture appearance of the crowns was much more complex than that of the overlay restorations. CONCLUSIONS Full coverage chairside CAD/CAM lithium disilicate premolar crown showed higher fracture resistance than overlay restorations. Overlays with the margin located 2 mm above the margin demonstrated higher resistance than those with the margin located 4 mm above the gingiva.
Collapse
Affiliation(s)
- Carlos Alberto Jurado
- Woody L. Hunt School of Dental Medicine, Texas Tech University Health Sciences Center El Paso, El Paso, TX
| | - Zinaida Kaleinikova
- Comprehensive Care Unit, A.T. Still University Arizona School of Dentistry & Oral Health, Mesa, AZ
| | - Akimasa Tsujimoto
- Department of Operative Dentistry, University of Iowa College of Dentistry, Iowa City, IA
| | | | - Robert R Seghi
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, OH
| | - Damian J Lee
- Advanced Prosthodontics Program, The Ohio State University College of Dentistry, Columbus, OH
| |
Collapse
|
68
|
Comparison of Mechanical Properties of Chairside CAD/CAM Restorations Fabricated Using a Standardization Method. MATERIALS 2021; 14:ma14113115. [PMID: 34204092 PMCID: PMC8200951 DOI: 10.3390/ma14113115] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 06/02/2021] [Accepted: 06/03/2021] [Indexed: 11/18/2022]
Abstract
The aim of this in vitro study was to investigate the fracture resistance, fracture failure pattern, and fractography of four types of chairside computer-aided design/computer-aided manufacturing (CAD/CAM) restoration materials in teeth and titanium abutments fabricated using a standardization method. An artificial mandibular left first premolar prepared for all-ceramic crown restoration was scanned. Forty extracted mandibular molars and cylindrical titanium specimens were milled into a standardized shape. A total of eighty CAD/CAM restoration blocks were milled into a crown and twenty pieces of each lithium disilicate (LS), polymer-infiltrated-ceramic-network (PICN), resin nano ceramic (RNC), and zirconia-reinforced lithium silicate (ZLS) materials were used. Crowns were bonded to abutments, and all specimens underwent thermal cycling treatment for 10,000 cycles. Fracture resistance was measured using a universal testing machine and fracture failure patterns were analyzed using optical microscopy and scanning electron microscopy. Statistical differences were analyzed using appropriate ANOVA, Tukey HSD post hoc tests, and independent sample t-tests (α = 0.05). The results indicated that, in both teeth abutments and titanium abutments, the fracture resistances showed significantly the highest values in LS and the second highest in ZLS (p < 0.05). The fracture resistances based on teeth abutments and titanium abutments were significantly different in all the CAD/CAM restoration materials (p < 0.05). There are statistically significant correlations between the types of materials and the types of abutments (p < 0.05). Each of the different materials showed different fracture failure patterns, and there was no noticeable difference in fractographic analysis. Lithium disilicates and zirconia-reinforced lithium silicates exhibited statistically high fracture resistance, indicating their suitability as restoration materials for natural teeth or implant abutments. There were no distinct differences in the fracture pattern based on the restoration and abutment materials showed that the fracture initiated at the groove where the ball indenter was toughed and propagated toward the axial wall.
Collapse
|
69
|
Saratti CM, Rocca GT, Durual S, Lohbauer U, Ferracane JL, Scherrer SS. Fractography of clinical failures of indirect resin composite endocrown and overlay restorations. Dent Mater 2021; 37:e341-e359. [DOI: 10.1016/j.dental.2021.02.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 01/28/2021] [Accepted: 02/05/2021] [Indexed: 10/22/2022]
|
70
|
Pilecco RO, Dalla-Nora F, Guilardi LF, Pereira GKR, de Andrade GS, de Melo RM, Valandro LF, Rippe MP. In-lab simulation of CAD/CAM milling of lithium disilicate glass-ceramic specimens: Effect on the fatigue behavior of the bonded ceramic. J Mech Behav Biomed Mater 2021; 121:104604. [PMID: 34087550 DOI: 10.1016/j.jmbbm.2021.104604] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 05/11/2021] [Accepted: 05/17/2021] [Indexed: 10/21/2022]
Abstract
The aim of this study was to evaluate the effect of in-lab simulation procedures performed on a lithium disilicate ceramic luted to a dentin-analogue material regarding the fatigue performance and topographic changes. Lithium disilicate ceramic (IPS e.max CAD) discs (Ø = 13.5 mm and 1.5 mm of thickness) were produced in different ways: milled in a CAD/CAM system (CAD/CAM - control group); mirror-polished (POL group); produced in-lab and ground with #60 silicon carbide paper (SiC group); with #60 wood sandpaper (WS group); with a fine diamond bur (DB group); or with a CAD/CAM bur adapted in a handpiece with a custom mandrel (MANDREL group). The ceramic discs were adhesively luted (Multilink N) onto dentin analogue discs (Ø = 12 mm and 2 mm of thickness) and fatigue testing (n = 19 discs) was performed by step-stress methodology (initial load of 200 N; step-size of 50 N; 10,000 cycles per step; 20 Hz). Surface roughness and contact angle analysis were also performed. According to Kaplan-Meier and post-hoc Mantel-Cox (log-rank), distinct fabrication methods affected the fatigue performance of bonded glass-ceramic discs (p< 0.001). The CAD/CAM group presented the lowest fatigue failure loads (1250 N) and number of cycles for failure (185,000), while the POL groups obtained the highest results (1752 N; 284,444 cycles). The in-lab groups had intermediate values (1355 - 1526 N; 206,052 - 238,684 cycles). Polished specimens presented the lowest roughness values (Ra = 0.041 μm), while the SiC (1.604 μm), WS (1.701 μm), and MANDREL (1.867 μm) groups showed statistically similar roughness values to the CAD/CAM group (1.738 μm). Despite differences before etching, the contact angle was similar among the milled and simulated groups after etching, except for the polished group. Even with some topographic similarities, the tested in-lab simulation methods were not able to mimic the milled specimens in terms of fatigue findings, leading to distinct magnitude of overestimations of the results.
Collapse
Affiliation(s)
- Rafaela Oliveira Pilecco
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Fernanda Dalla-Nora
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luís Felipe Guilardi
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Guilherme Schmitt de Andrade
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo, Brazil.
| | - Renata Marques de Melo
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology ICT/SJC, São Paulo State University - UNESP, São José dos Campos, São Paulo, Brazil.
| | - Luiz Felipe Valandro
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Marília Pivetta Rippe
- MSciD and PhD Graduate Programs in Oral Science - Prosthodontic Units, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
71
|
Schönhoff LM, Lümkemann N, Buser R, Hampe R, Stawarczyk B. Fatigue resistance of monolithic strength-gradient zirconia materials. J Mech Behav Biomed Mater 2021; 119:104504. [PMID: 33845296 DOI: 10.1016/j.jmbbm.2021.104504] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 03/24/2021] [Accepted: 03/29/2021] [Indexed: 11/18/2022]
Abstract
PURPOSE Evaluation of the effect of three different dynamic fatigue protocols on the fracture resistance of two monolithic strength-gradient zirconia materials. MATERIALS AND METHODS A total of 240 specimens (3 × 4 × 45 mm) was milled from two different layers (incisal and middle) of two types of strength-gradient zirconia blanks (IPS e. max ZirCAD MT Multi A2 vs. IPS e. max ZirCAD Prime A2), resulting in 60 specimens per material and layer group (IPS e. max ZirCAD MT Multi A2: incisal (MI), middle (MM); IPS e. max ZirCAD Prime A2: incisal (PI), middle (PM)). Each group was divided into one static (n = 15) and three dynamic fatigue protocols (N = 45, n = 15): i. 50 N increase every 5000 cycles ii. Increase by 5% of static fracture load every 5000 cycles iii. 10 N increase every 1000 cycles until facture. All specimens were loaded until facture in CeraTest 2 k. Kaplan-Meier, Log-Rank and Chi-squared-test as well as Weibull statistics were performed. A fractographic analysis was performed. The specimens were classified according to the number of crack origins and evaluated using the Ciba-Geigy table. RESULTS With regard to the fracture load, in the static loading MI and PI showed a higher fracture load and in dynamic fatigue protocol 2 PI showed a lower fracture load. The number of cycles until fracture only differed within three groups: MM and MI survived a higher number of cycles in dynamic fatigue protocol 2; PI survived a higher number of cycles in dynamic fatigue protocol 2 than in protocol 1. Within dynamic fatigue protocols, PM resisted the highest number of cycles in protocol 1 and 3 and MI in protocol 2. Comparing groups, Weibull modulus differed only within the static loading, with PI showing lower values than MM and MI. Within the material groups, MI showed higher values in static loading than in dynamic fatigue protocol 1 and 2, and PI showed higher values in the dynamic fatigue protocol 3 than in static loading. With regard to fracture patterns, no differences were found between the groups. CONCLUSIONS Dynamic fatigue protocols provide clinically relevant information on the long-term stability and reliability of monolithic strength-gradient zirconia materials. However, no definitive instructions for dynamic testing can be provided from this investigation.
Collapse
Affiliation(s)
- Lisa Marie Schönhoff
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Nina Lümkemann
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Ramona Buser
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Rüdiger Hampe
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany
| | - Bogna Stawarczyk
- Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336, Munich, Germany.
| |
Collapse
|
72
|
Chantler JGM, Judge RB, Palamara JEA, Abduo J. Influence of the application of a pre-sintered surface augmentation on zirconia and lithium disilicate bonding using an adhesive composite resin cement. Dent Mater 2021; 37:e382-e390. [PMID: 33775454 DOI: 10.1016/j.dental.2021.02.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 02/16/2021] [Accepted: 02/24/2021] [Indexed: 11/15/2022]
Abstract
OBJECTIVE The purpose of this laboratory study is to evaluate the application of a pre-sintered surface augmentation to zirconia (Zir) and lithium disilicate (LDS) ceramics on the delamination strength of adhesive resin cement. The applied surface augmentation was the ruling of lines to the pre-sintered surface of the ceramics. METHODS Ninety milled Zir and sixty pressed LDS specimens (3mm×0.5mm×25mm) were created and divided into five groups (n=30). Group 1: Zir no surface treatment (control Zir-NT); Group 2: Zir airborne particle abraded (Zir-APA) with 30μm CoJet; Group 3: Zir pre-sintered surface augmentation (Zir-SA); Group 4: LDS etched (control LDS-etched) and; Group 5: LDS with pre-sintered surface augmentation and etching (LDS-SA). A resin adhesive cement (3mm×1mm×8mm) was then applied and cured to the ceramic specimens. The delamination strength values of the resin cement from the ceramic were recorded. The delamination strength data were analysed statistically using one-way ANOVA and Turkey post hoc analysis. RESULTS The mean delamination strength and standard deviation, when comparing only the Zir-SA to the resin cement were statistically different (p<0.001); Zir-SA 63.42±11.85, Zir-NT 26.82±12.07, and Zir-APA 48.11±17.85MPa. Comparison between LDS groups were not significantly different (p=0.193); LDS-etched 33.49±16.07 and LDS-SA 28.83±10.15MPa. The delaminated Weibull modulus was highest for surface augmentation Zir specimens (m=13.56) but decreasing to less than half for Zir-APA (m=6.27) and Zir-NT (m=5.68). The Weibull values for the LDS-SA and LDS-etched specimens was 5.63 and 3.38 respectively. SIGNIFICANCE Incorporating the pre-sintered surface augmentation to zirconia improved the delamination strength and reliability of Zir to the resin cement but not for LDS.
Collapse
Affiliation(s)
| | - Roy B Judge
- Head of Prosthodontics, Melbourne Dental School, University of Melbourne, Melbourne, Victoria, Australia.
| | - Joseph E A Palamara
- Coordinator of Materials Science, Restorative Dentistry Department, Melbourne Dental School, University of Melbourne, Melbourne, Australia
| | - Jaafar Abduo
- Convenor of Postgraduate Diploma in Clinical Dentistry, Melbourne Dental School, University of Melbourne, Melbourne, Australia
| |
Collapse
|
73
|
Influence of surface treatments and cyclic fatigue on subsurface defects and mechanical properties of zirconia frameworks. Dent Mater 2021; 37:905-913. [PMID: 33691991 DOI: 10.1016/j.dental.2021.02.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 02/16/2021] [Accepted: 02/24/2021] [Indexed: 11/22/2022]
Abstract
OBJECTIVES To evaluate the effect of laser fused and air abraded fluorapatite particles on flexural strength σf and fracture toughness (KIC) of Yttria tetragonal zirconia polycrystal (Y-TZP). METHODS 160 polished Y-TZP bars received one of the following surface treatments: airborne particle abrasion (APA) with fluorapatite glass-ceramics (FGC), APA with tribochemical silica-coated alumina (CoJet), laser fused FGC using Nd:YAG Laser (FGC + Laser), while as-sintered polished specimens served as control. Initial flexural strength σfI was measured to half of the specimens, while the rest underwent cyclic fatigue (1,000,000 cycle of 15N load and 3 s contact time) followed by measuring residual flexural strength σfR. Fractographic analysis was performed and KIC was calculated. The effect of surface treatment and fatigue on flexural strength was statistically analysed using 2-way ANOVA (α = 0.05). Weibull probability was measured to assess the reliability of flexural strength. RESULTS The highest σf before or after the fatigue was reported for the control group while the lowest was for FGC + Laser group. Cyclic fatigue significantly decreased the flexural strength of all groups except for FGC + Laser group. There was no significant difference between the KIC between the control and FGC groups, however, a significant reduction of KIC was found in the CoJet group, while FGC + Laser reported the significant lowest value compared to all groups (P = 0.00). SIGNIFICANCE Fluorapatite glass-ceramic powder offers a promising alternative for particle abrasion of zirconia-based frameworks.
Collapse
|
74
|
Iijima N, Homma S, Nakano R, Hayashi S, Hirano T, Iijima T, Yajima Y. Fatigue properties of hollow zirconia implants. Dent Mater J 2021; 40:885-893. [PMID: 33692224 DOI: 10.4012/dmj.2020-248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The objective of this study was to clarify the fatigue behavior of hollow yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) specimens assuming its use for two-piece implants. The fatigue properties of a solid specimen (which simulated a one-piece implant) and 3 types of hollow specimens (which simulated two-piece implants) were evaluated. Specimens were either solid with a diameter of 4.0 mm (S) or hollow with an inner diameter of 3.0 mm and outer diameters of 4.0 mm (H0.5), 4.5 mm (H0.75), or 5.0 mm (H1.0). For each group, 25 specimens were prepared followed by blast and acid etch treatment. Static fracture and cyclic fatigue tests were conducted by modifying the methods provided in ISO6872. Fracture modes were determined by observing the surfaces under a scanning electron microscope. As a result, the cyclic fatigue load of S and H1.0 were similar, and hollow specimens with outer diameters greater than 0.75 mm displayed the ability to withstand molar occlusal forces.
Collapse
Affiliation(s)
- Noriko Iijima
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Shinya Homma
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Ryotaro Nakano
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Shota Hayashi
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Tomoki Hirano
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Toshihiko Iijima
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| | - Yasutomo Yajima
- Department of Oral and Maxillofacial Implantology, Tokyo Dental College
| |
Collapse
|
75
|
Spintzyk S, Geis-Gerstorfer J, Bourauel C, Keilig L, Lohbauer U, Brune A, Greuling A, Arnold C, Rues S, Adjiski R, Sawada T, Lümkemann N, Stawarczyk B, Ilie N, Frankenberger R, Dudek MC, Strickstrock M, Begand S. Biaxial flexural strength of zirconia: A round robin test with 12 laboratories. Dent Mater 2020; 37:284-295. [PMID: 33358016 DOI: 10.1016/j.dental.2020.11.016] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 09/02/2020] [Accepted: 11/21/2020] [Indexed: 11/16/2022]
Abstract
OBJECTIVE The aim of this interlaboratory round robin test was to prove the robustness of the DIN EN ISO 6872:2019 and to identify the influence of processing and testing variations. METHODS Each of the 12 laboratories participated (A-L) received 60 (n = 720) assigned zirconia specimens. All participants seperated the specimens from the blanks, sintered them, polished half of all specimens and performed the biaxial flexural test (DIN EN ISO 6872:2019). The surface roughness was determined by using tactile measuring device. Fractographic examination was performed under scanning-electron-microscopy (SEM). Data was analysed using Kolmogorov-Smirnov-, Kruskal-Wallis-, Mann-Whitney-U-test and two-parametric Weibull statistic (p < 0.05). RESULTS The results for both preparation methods (as-fired and polished) showed significant differences for some participants. The values for as-fired groups ranged between 513 (I) and 659 (E) MPa. H showed higher Weibull modulus than C, E and I. Within polished groups flexural strengths values from 465 (L) to 1212 (E) MPa were observed, with a tendency to clustered groups A, I, J, L (465-689 MPa) and remaining groups (877-1212 MPa). E presented the highest and H the lowest Weibull modulus. Within A and J, no impact of the preparation method on flexural strength values was observed. Within L, as-fired specimens showed higher flexural strength than polished ones. The flexural strength increase did only associate to a certain extent with measured surface roughness. Fractography showed defect populations depending on polishing techniques, associated to the strength level, especially for polished groups. Reduced strength is related to machining defects, regardless of the surface state. SIGNIFICANCE DIN EN ISO 6872:2019 can be seen as guidance to biaxial flexural strength testing but additional effort is necessary to ensure interlaboratory comparability. Calibrated furnaces and reliable sintering conditions are mandatory requirements together with detailed specifications on finishing or polishing procedures. Biaxial flexural testing is really a matter of understanding specimen preparation, alignment and mechanical testing by itself. DIN EN ISO 6872:2019 should further recommend reporting of mean surface roughness along with any biaxial flexural strength data. Fractography is a mandatory tool in interpretation and understanding of strength data.
Collapse
Affiliation(s)
- Sebastian Spintzyk
- University Hospital Tübingen, Section "Medical Materials Science & Technology", Osianderstr. 2-8, 72076 Tuebingen, Germany.
| | - Jürgen Geis-Gerstorfer
- University Hospital Tübingen, Section "Medical Materials Science & Technology", Osianderstr. 2-8, 72076 Tuebingen, Germany
| | - Christoph Bourauel
- University Hospital Bonn, Oral Technology, School of Dentistry, University of Bonn, Welschnonnenstr. 17, 53111 Bonn, Germany
| | - Ludger Keilig
- University Hospital Bonn, Oral Technology, School of Dentistry, University of Bonn, Welschnonnenstr. 17, 53111 Bonn, Germany
| | - Ulrich Lohbauer
- University of Erlangen-Nuremberg, Dental Clinic 1 - Operative Dentistry and Periodontology, Glueckstrasse 11, 91054 Erlangen, Germany
| | - Annike Brune
- Hannover Medical School, Clinic for Dental Prosthetics, Carl-Neuberg-Straße 1, 30625 Hannover, Germany
| | - Andreas Greuling
- Hannover Medical School, Clinic for Dental Prosthetics, Carl-Neuberg-Straße 1, 30625 Hannover, Germany
| | - Christin Arnold
- Department of Prosthodontics, School of Dental Medicine, Martin-Luther-University, Magdeburger Str. 16, 06112 Halle (Saale), Germany
| | - Stefan Rues
- Department of Prosthodontics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Ranko Adjiski
- Otto Schott Institute of Materials Research, Friedrich Schiller University Jena, Löbdergraben 32, 07743 Jena, Germany
| | - Tomofumi Sawada
- Department of Prosthodontics, University Hospital Tübingen, Osianderstr. 2, -8, 72076 Tübingen, Germany
| | - Nina Lümkemann
- Department of Prosthetic Dentistry, University Hospital, Dental School, Ludwig-Maximilians-University Munich, Goethestraße 70, 80336 Munich, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, University Hospital, Dental School, Ludwig-Maximilians-University Munich, Goethestraße 70, 80336 Munich, Germany
| | - Nicoleta Ilie
- Department of Operative Dentistry and Periodontology, University Hospital, Dental School, Ludwig-Maximilians-University Munich, Goethestraße 70, 80336 Munich, Germany
| | - Roland Frankenberger
- Department of Operative Dentistry, Endodontics and Pediatric Dentistry, Medical Center for Dentistry, University Medical Center Giessen and Marburg, Campus Marburg, Georg-Voigt-Str. 3, 35039 Marburg, Germany
| | - Marie-Christine Dudek
- Department of Operative Dentistry, Endodontics and Pediatric Dentistry, Medical Center for Dentistry, University Medical Center Giessen and Marburg, Campus Marburg, Georg-Voigt-Str. 3, 35039 Marburg, Germany
| | - Monika Strickstrock
- Faculty of Engineering and Computer Science, Material Science and Analysis, University of Applied Sciences Osnabrück, Albrechtstrasse 30, Osnabrück 49076, Germany
| | - Sabine Begand
- Fraunhofer Institute for Ceramics Technologies and Systems IKTS, Michael-Faraday-Str. 1, 07639 Hermsdorf, Germany
| |
Collapse
|
76
|
Dal Piva AMDO, Tribst JPM, Benalcázar Jalkh EB, Anami LC, Bonfante EA, Bottino MA. Minimal tooth preparation for posterior monolithic ceramic crowns: Effect on the mechanical behavior, reliability and translucency. Dent Mater 2020; 37:e140-e150. [PMID: 33246664 DOI: 10.1016/j.dental.2020.11.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 08/10/2020] [Accepted: 11/02/2020] [Indexed: 11/29/2022]
Abstract
OBJECTIVE Despite the increased use of monolithic crowns, their performance has yet to be determined when the minimal tooth preparation (MTP) principle is considered. The goal of this study was to evaluate the effect of MTP on the mechanical behavior, reliability and translucency of posterior monolithic ceramic crowns. METHODS Dentin analogues were machined using two preparation designs (0.5 or 1 mm reduction) to receive first molar crowns in order to evaluate the monolithic crown performance. Next, 126 crowns were divided (21/g) according to the material (High translucent zirconia - YZHT, Zirconia reinforced lithium silicate - ZLS and Hybrid ceramic - HC) and thickness (0.5 or 1 mm). Tensile stress concentration was calculated using the finite element method. The crowns were adhesivelly cemented and step stress fatigued to calculate reliability for missions at 600 and 1000 N. Translucency was analyzed in 10 discs of each material and thickness. RESULTS Higher stress concentration was found in thinner crowns and those with higher elastic modulus. YZHT crowns were suspended when fatigue reached 1500 N load, thus 1-parameter Weibull was used to analyze the data. Reliability was only affected by thickness at 1000 N. ZLS.5 showed lower survival than HC.5, which was similar to the groups that presented 100% survival. YZHT showed the highest strength and data scattering. ZLS1 (22.3 ± 1.4) presented higher translucency than HC1 (19.2 ± 0.6) and YZHT1 (12.0 ± 2.9), whereas ZLS.5 and HC.5 were similar to each other (26.5 ± 2.3, 26.7 ± 2.2) and superior to YZHT.5 (12.7 ± 1.2). SIGNIFICANCE HC.5 combined high reliability and translucency with low stress concentration, yielding better crown performance and tooth preservation.
Collapse
Affiliation(s)
- Amanda Maria de Oliveira Dal Piva
- PhD Graduate Program in Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, nº 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil.
| | - João Paulo Mendes Tribst
- PhD Graduate Program in Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, nº 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil.
| | - Ernesto Byron Benalcázar Jalkh
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry. Alameda Dr. Octávio Pinheiro Brisolla, 9-75, 17012-901, Bauru, SP, Brazil.
| | - Lilian Costa Anami
- PhD Graduate Program in Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, nº 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil.
| | - Estevam Augusto Bonfante
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry. Alameda Dr. Octávio Pinheiro Brisolla, 9-75, 17012-901, Bauru, SP, Brazil.
| | - Marco Antonio Bottino
- PhD Graduate Program in Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, nº 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil.
| |
Collapse
|
77
|
Juica D, Marcus N, Grandon F, Sanhueza V, Wendler M. Premature failure of a screw-retained ceramic single crown: A clinical report and fractographic analysis. J Prosthet Dent 2020; 127:32-37. [PMID: 33190861 DOI: 10.1016/j.prosdent.2020.06.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 06/15/2020] [Accepted: 06/15/2020] [Indexed: 10/23/2022]
Abstract
Screw-retained implant-supported ceramic restorations have shown increased rates of technical complications compared with their cemented counterparts, including fracture and chipping of the ceramic structures. The present clinical report identified the causes leading to the catastrophic failure of a screw-retained lithium disilicate veneered crown cemented to a zirconia abutment with a titanium base by using a systematic fractographic approach. A combination of occlusal overloading, a deficient design and inadequate material selection was identified as being responsible for the fracture. These findings highlight the importance of a thorough analysis of the anatomic conditions and loading scenario of screw-retained implant-supported restorations.
Collapse
Affiliation(s)
- Daniel Juica
- Graduate student, Postgraduate Program in Oral and Maxillofacial Implantology, Faculty of Dentistry, University of Concepción, Concepción, Chile
| | - Natalia Marcus
- Assistant Professor, Department of Restorative Dentistry, Faculty of Dentistry, University of Concepción, Concepción, Chile
| | - Fernando Grandon
- Assistant Professor, Department of Restorative Dentistry, Faculty of Dentistry, University of Concepción, Concepción, Chile
| | - Vilma Sanhueza
- Associate Professor, Universidad de Concepción, Instituto de Geología Económica Aplicada (GEA), Concepción, Chile
| | - Michael Wendler
- Assistant Professor, Department of Restorative Dentistry, Faculty of Dentistry, University of Concepción, Concepción, Chile.
| |
Collapse
|
78
|
Skjold A, Schriwer C, Gjerdet NR, Øilo M. Effect of artificial aging on high translucent dental zirconia: simulation of early failure. Eur J Oral Sci 2020; 128:526-534. [PMID: 33058363 DOI: 10.1111/eos.12739] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 09/04/2020] [Accepted: 09/10/2020] [Indexed: 01/02/2023]
Abstract
Higher yttria content enhances the translucency and appearance of dental zirconia materials. Alterations in material composition also affect mechanical properties. The aim of this study was to compare the fracture load after artificial short-term aging of monolithic, full-contour zirconia crowns with different amounts of yttria-stabilization. Sixty crowns (thirty super high translucent crowns (5Y-Z) and thirty high translucent crowns (3Y-Z)) were produced to fit a model of a premolar with a shallow chamfer preparation. The crowns were cemented with self-adhesive resin cement on composite abutments. For each zirconia type, three groups of crowns (n = 10) were allocated to: (i) cyclic loading (200 N, 1 Hz, 30,000 cycles), (ii) hydrothermal aging (3 × 20 min, 134°C 3.2 bar), or (iii) no treatment (control). Surviving crowns from the aging process were quasistatically loaded until fracture. The 3Y-Z crowns had statistically significantly higher fracture values (3,449 N) than the 5Y-Z crowns (1,938 N). The aging procedures did not affect load at fracture. Fractographic analysis showed that fractures started either at the crown margin or at the occlusal intaglio area. Higher yttria content leads to a reduction in material strength and damage tolerance, and this should be reflected in recommendations for clinical use.
Collapse
Affiliation(s)
- Anneli Skjold
- Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Bergen, Norway
| | - Christian Schriwer
- Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Bergen, Norway
| | - Nils R Gjerdet
- Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Bergen, Norway
| | - Marit Øilo
- Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Bergen, Norway
| |
Collapse
|
79
|
Fuchs F, Koenig A, Poppitz D, Hahnel S. Application of macro photography in dental materials science. J Dent 2020; 102:103495. [PMID: 33038439 DOI: 10.1016/j.jdent.2020.103495] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 09/15/2020] [Accepted: 10/03/2020] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVES The goal of this study was to show the potential of the inexpensive macro photography technique for application in various fields of contemporary dental materials science. The method was used for studying surface characteristics for fractographic evaluation, topography analysis, and for the measurement of optical properties such as translucency and opalescence. MATERIALS AND METHODS The variable test setup consisted of a digital camera with macro or microscopic objectives (combined with a lens tube and an objective adapter). The distance between object surface and objectives was controlled by an automatic stacking unit with a software-controlled mobile object slide. The exposure was carried out by LED light sources and a standard illuminant (D55). RESULTS Highly resolved pictures with fine details, high focal depth, flexible imaging by adjusting the illuminates in different angles, and the possibility of 3D topography imaging are the main reasons why macro photography proved to be a suitable imaging method for fractographic analyses. The automatic focal stacking technique was a powerful tool for imaging distinct topographies in high-resolution with nearly unlimited focal depth and 3D surface visualisation. Translucency as well as opalescence, measured with the macro photography produced differed from the measurements performed with a conventional spectrophotometer. CONCLUSIONS The modular structure of the cost-effective macro photography setup enables diverse applications such as identification of material groups, fractography analysis, and 3D surface visualisation. Quantification of colour, translucency, as well as opalescence under condition of the microscopic scale requires further research.
Collapse
Affiliation(s)
- Florian Fuchs
- Department of Prosthetic Dentistry and Dental Material Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany.
| | - Andreas Koenig
- Department of Prosthetic Dentistry and Dental Material Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany
| | - David Poppitz
- Institute of Chemical Technology, Leipzig University, Linnestraße 3, 04103 Leipzig, Germany
| | - Sebastian Hahnel
- Department of Prosthetic Dentistry and Dental Material Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany
| |
Collapse
|
80
|
Quantitative and qualitative analyses of ceramic chipping. J Mech Behav Biomed Mater 2020; 110:103928. [DOI: 10.1016/j.jmbbm.2020.103928] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 06/06/2020] [Accepted: 06/09/2020] [Indexed: 11/23/2022]
|
81
|
Miura S, Yamauchi S, Kasahara S, Katsuda Y, Fujisawa M, Egusa H. Clinical evaluation of monolithic zirconia crowns: a failure analysis of clinically obtained cases from a 3.5-year study. J Prosthodont Res 2020; 65:148-154. [PMID: 32938882 DOI: 10.2186/jpr.jpor_2019_643] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE The primary purpose of this study was to examine the clinical performance of monolithic zirconia single crowns in terms of short-term failure or complications. The secondary purpose was to detect the originating flaws of clinically failed monolithic zirconia crowns to find the causes of failure. METHODS A short-term prospective cohort study based on record evaluation and clinical examination of patients treated with tooth-supported monolithic zirconia crowns was performed in the Department of Fixed Prosthodontics, Tohoku University Hospital, Japan. The crowns were prepared during the follow-up period from April 2014 to July 2018. The 3.5-year cumulative success and survival rates were set as primary endpoints. Fractures of the crown or fragments were inspected under a scanning electron microscope for descriptive fractography. RESULTS During the study period, 40 monolithic zirconia crowns were placed. Four crowns experienced clinical complications, including: 1) fracture of the crown (two crowns), 2) abrasion of the crown (one crown), and 3) fracture of the antagonist tooth (one crown). The estimated Kaplan-Meier 3.5-year success and survival rates were 90.5% (95% confi dence interval [CI]: 73.1-97.1) and 92.8% (95% CI: 74.1-98.3), respectively. Fractography revealed that all fractures were initiated from the wear phase on the occlusal surface. CONCLUSIONS The results of this study suggest that the molar application of monolithic zirconia crowns requires detailed attention to interocclusal clearance and the restoration of the antagonist tooth.
Collapse
Affiliation(s)
- Shoko Miura
- Division of Fixed Prosthodontics, Department of Restorative & Biomaterials Sciences, Meikai University School of Dentistry, Sakado.,Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai
| | - Shinobu Yamauchi
- Department of Biomaterials, Nihon University School of Dentistry at Matsudo
| | - Shin Kasahara
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai
| | - Yusuke Katsuda
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai
| | - Masanori Fujisawa
- Division of Fixed Prosthodontics, Department of Restorative & Biomaterials Sciences, Meikai University School of Dentistry, Sakado
| | - Hiroshi Egusa
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai
| |
Collapse
|
82
|
Ghoul WE, Özcan M, Tribst JPM, Salameh Z. Fracture resistance, failure mode and stress concentration in a modified endocrown design. Biomater Investig Dent 2020; 7:110-119. [PMID: 32939455 PMCID: PMC7470158 DOI: 10.1080/26415275.2020.1801348] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Purpose The purpose of this study was to assess fracture resistance, failure mode and stress concentration of a modified endocrown preparation design, under axial and lateral forces. Materials and Methods Forty lower molars were divided into two groups (n = 20) and were restored with lithium disilicate glass-ceramic endocrowns following 2 preparation designs: Conventional, with circumferential butt margin 2 mm above the cemento–enamel junction; and Modified, by adding 2 grooves on the mesial side of the vestibular dentinal wall and on the distal side of the lingual dentinal wall. After cementation and thermomechanical cycling loading, half of the samples (n = 10) from each group were loaded axially and the other half (n = 10) was loaded laterally. Fracture resistance and failure modes were observed and the finite element analysis (FEA) was used to identify the stress concentration. Two-way ANOVA and Chi-square tests (α = 0.05) were used for in vitro data analyzes. Results Fracture resistance showed a statistically significant difference between conventional and modified preparations (p < .001), and between axial and lateral loadings (p < .001). Conventional preparation recorded 2914 N under axial loading and 1516 N under lateral loading, while modified preparation recorded 3329 N under axial loading and 1871 N under lateral loading. FEA showed that retention grooves have reduced the stress concentration under both loads for the tooth and the restoration. Conclusion Modified endocrown design showed higher fracture resistance than conventional endocrown. Lateral loading displayed a high percentage of severe fracture but under higher load to failure than the values reported for normal masticatory forces.
Collapse
Affiliation(s)
- Wiam El Ghoul
- Department of Prosthodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| | - Mutlu Özcan
- Division of Dental Biomaterials, Centre of Dental Medicine, Clinic of Reconstructive Dentistry, University of Zurich, Zurich, Switzerland
| | - Joao Paulo Mendes Tribst
- Department of Dental Materials and Prosthodontics, São Paulo State University, Institute of Science and Technology, São José dos Campos, Brazil
| | - Ziad Salameh
- Department of Prosthodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| |
Collapse
|
83
|
Naves LZ, Gerdolle DA, de Andrade OS, Markus Maria Gresnigt M. Seeing is believing? When scanning electron microscopy (SEM) meets clinical dentistry: The replica technique. Microsc Res Tech 2020; 83:1118-1123. [PMID: 32643268 DOI: 10.1002/jemt.23503] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 04/06/2020] [Accepted: 04/16/2020] [Indexed: 11/08/2022]
Abstract
In restorative dentistry, the in situ replication of intra-oral situations, is based on a non-invasive and non-destructive scanning electron microscopy (SEM) evaluation method. The technique is suitable for investigation restorative materials and dental hard- and soft-tissues, and its interfaces. Surface characteristics, integrity of interfaces (margins), or fracture analysis (chipping, cracks, etc.) with reliable resolution and under high magnification (from ×50 to ×5,000). Overall the current study aims to share detailed and reproducible information about the replica technique. Specific goals are: (a) to describe detailed each step involved in producing a replica of an intra-oral situation, (b) to validate an integrated workflow based on a rational sequence from visual examination, to macrophotography and SEM analysis using the replica technique; (c) to present three clinical cases documented using the technique. A compilation of three clinical situations/cases were analyzed here by means the replica technique showing a wide range of possibilities that can be reached and explored with the described technique. This guidance document will contribute to a more accurate use of the replica technique and help researchers and clinicians to understand and identify issues related to restorative procedures under high magnification.
Collapse
Affiliation(s)
- Lucas Zago Naves
- Department of Restorative Dentistry and Biomaterials, University Medical Center Groningen, The University of Groningen, Center for Dentistry and Oral Hygiene, Groningen, The Netherlands
| | | | | | - Marco Markus Maria Gresnigt
- Department of Restorative Dentistry and Biomaterials, University Medical Center Groningen, The University of Groningen, Center for Dentistry and Oral Hygiene, Groningen, The Netherlands.,Department of Special Dental Care, Martini Hospital, Groningen, The Netherlands
| |
Collapse
|
84
|
Oh WS. Cement Type (Adhesive vs. Conventional) May Not Affect Clinical Performance of Zirconia and Lithium Disilicate Tooth-Supported Crowns. J Evid Based Dent Pract 2020; 20:101415. [PMID: 32473801 DOI: 10.1016/j.jebdp.2020.101415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION Effect of cement type on the clinical performance and complications of zirconia and lithium disilicate tooth-supported crowns: A systematic review. Report of the Committee on Research in Fixed Prosthodontics of the American Academy of Fixed Prosthodontics. Maroulakos G, Thompson GA, Kontogiorgos ED. J Prosthet Dent 2019;121:754-65. SOURCE OF FUNDING Unknown. TYPE OF STUDY/DESIGN Systematic review.
Collapse
|
85
|
Wiedenmann F, Pfefferle R, Reichert A, Jerman E, Stawarczyk B. Impact of high-speed sintering, layer thickness and artificial aging on the fracture load and two-body wear of zirconia crowns. Dent Mater 2020; 36:846-853. [PMID: 32414506 DOI: 10.1016/j.dental.2020.04.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Revised: 03/18/2020] [Accepted: 04/13/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVE To investigate the impact of high-speed sintering, layer thickness and artificial aging in a chewing simulator on the fracture load (FL) and two-body wear (2BW) of 4Y-TZP crowns. METHODS 4Y-TZP crowns (Ceramill Zolid HT+, Amann Girrbach AG) in three different layer thicknesses (0.5, 1.0, 1.5; N=192, n=64/group) were manufactured using CAD/CAM technology and sintered at 1580°C (high-speed sintering) or 1450°C (control group). Specimens were polished in two-steps and bonded to standardized CoCr abutments with Multilink Automix (Ivoclar Vivadent). 2BW after 6000 thermo- and 1,200,000 chewing-cycles employing enamel antagonists was determined using best fit machining. FL was tested before and after artificial aging. Univariate ANOVAs, post hoc Scheffé, unpaired t-, Kruskal-Wallis- and Mann-Whitney-U-test were computed (p<0.05). RESULTS High-speed sintering resulted in less 2BW of the zirconia than the control group (p=0.013). High-speed sintering (p=0.001-0.006) and an increase in layer thickness (p<0.001-0.012) resulted in higher FL values, while artificial aging led to a reduction of FL (p<0.001). SIGNIFICANCE As high-speed sintering resulted in less two-body wear of the zirconia and comparable or even higher fracture load results than the control group, this cost- and time efficient alternative presents promising mechanical results.
Collapse
Affiliation(s)
- Felicitas Wiedenmann
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336 Munich, Germany.
| | - Regina Pfefferle
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336 Munich, Germany
| | - Axel Reichert
- Research & Development, Amann Girrbach GmbH, Herrschaftswiesen 1, 6842 Koblach, Austria
| | - Eva Jerman
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336 Munich, Germany
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336 Munich, Germany
| |
Collapse
|
86
|
Huang X, Zou L, Yao R, Wu S, Li Y. Effect of preparation design on the fracture behavior of ceramic occlusal veneers in maxillary premolars. J Dent 2020; 97:103346. [PMID: 32325176 DOI: 10.1016/j.jdent.2020.103346] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 03/27/2020] [Accepted: 04/15/2020] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVES The fracture strengths of four types of occlusal veneers and a traditional full crown ceramic restoration and the influence of preparation design on the stress of restorations were examined. METHODS Forty intact maxillary premolars randomly divided into five groups were prepared based on the demands of type O (occlusal surface coverage), OF (occlusal and lingual surface coverage), POF (occlusal, lingual, and mesial surface coverage), and POFP (occlusal, lingual, mesial, and distal surface coverage) veneers and full crown, and then restored by glass ceramic. Specimens were subjected to fracture resistance tests after cyclic loading. The fracture strengths and modes were analyzed statistically. The level of significance was set at α = 0.05. One maxillary premolar was prepared for type O, OF, POF, POFP veneer and full crown, and then scanned to establish finite element models. The mean fracture load was applied vertically to calculate the maximum principal stress on the ceramic. RESULTS Type O veneer showed higher fracture strength than type POF and POFP veneers (P < 0.05). Both type O and OF veneers exhibited higher fracture strength than full crown (P < 0.05). No significant difference in failure mode was observed. The maximum principal stress for type O, OF, POF, POFP veneers, and full crown increased progressively and concentrated at the bonding surface directly beneath the loading area. CONCLUSIONS Four types of occlusal veneer showed fracture strengths that considerably exceeded normal biting forces. They represent conservative alternatives to full crowns and present a viable treatment for severely worn teeth. CLINICAL SIGNIFICANCE The occlusal veneers with different preparation designs, including type O, OF, POF and POFP veneers, show higher fracture resistances than traditional full coverage crowns that considerably exceed the normal biting forces. Therefore, these represent conservative alternatives to crown restorations and present a viable treatment for restoring severely worn teeth.
Collapse
Affiliation(s)
- Xiaoqiong Huang
- Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, People's Republic of China.
| | - Leiyan Zou
- Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, People's Republic of China.
| | - Run Yao
- Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, People's Republic of China
| | - Shuyi Wu
- Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, People's Republic of China.
| | - Yan Li
- Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, People's Republic of China.
| |
Collapse
|
87
|
Survival Probability, Weibull Characteristics, Stress Distribution, and Fractographic Analysis of Polymer-Infiltrated Ceramic Network Restorations Cemented on a Chairside Titanium Base: An In Vitro and In Silico Study. MATERIALS 2020; 13:ma13081879. [PMID: 32316360 PMCID: PMC7216243 DOI: 10.3390/ma13081879] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Revised: 04/08/2020] [Accepted: 04/10/2020] [Indexed: 02/07/2023]
Abstract
Different techniques are available to manufacture polymer-infiltrated ceramic restorations cemented on a chairside titanium base. To compare the influence of these techniques in the mechanical response, 75 implant-supported crowns were divided in three groups: CME (crown cemented on a mesostructure), a two-piece prosthetic solution consisting of a crown and hybrid abutment; MC (monolithic crown), a one-piece prosthetic solution consisting of a crown; and MP (monolithic crown with perforation), a one-piece prosthetic solution consisting of a crown with a screw access hole. All specimens were stepwise fatigued (50 N in each 20,000 cycles until 1200 N and 350,000 cycles). The failed crowns were inspected under scanning electron microscopy. The finite element method was applied to analyze mechanical behavior under 300 N axial load. Log-Rank (p = 0.17) and Wilcoxon (p = 0.11) tests revealed similar survival probability at 300 and 900 N. Higher stress concentration was observed in the crowns’ emergence profiles. The MP and CME techniques showed similar survival and can be applied to manufacture an implant-supported crown. In all groups, the stress concentration associated with fractographic analysis suggests that the region of the emergence profile should always be evaluated due to the high prevalence of failures in this area.
Collapse
|
88
|
Fatigue degradation of bilayered ceramic structures under different biaxial loading schemes. J Mech Behav Biomed Mater 2020; 104:103651. [PMID: 32174409 DOI: 10.1016/j.jmbbm.2020.103651] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Revised: 01/21/2020] [Accepted: 01/21/2020] [Indexed: 11/22/2022]
|
89
|
LF G, P S, A W, de Jager N, GKR P, CJ K, MP R, LF V. Fatigue performance of distinct CAD/CAM dental ceramics. J Mech Behav Biomed Mater 2020; 103:103540. [DOI: 10.1016/j.jmbbm.2019.103540] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Revised: 11/13/2019] [Accepted: 11/14/2019] [Indexed: 02/02/2023]
|
90
|
Dartora NR, Maurício Moris IC, Poole SF, Bacchi A, Sousa-Neto MD, Silva-Sousa YT, Gomes EA. Mechanical behavior of endocrowns fabricated with different CAD-CAM ceramic systems. J Prosthet Dent 2020; 125:117-125. [PMID: 32057485 DOI: 10.1016/j.prosdent.2019.11.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 11/01/2019] [Accepted: 11/01/2019] [Indexed: 10/25/2022]
Abstract
STATEMENT OF PROBLEM The mechanical behavior of ceramic endocrowns is unclear. PURPOSE The purpose of this in vitro and 3-dimensional finite element analysis (3D-FEA) study was to evaluate the mechanical behavior of endodontically treated teeth restored with ceramic endocrowns made by using different computer-aided design and computer-aided manufacturing (CAD-CAM) systems. MATERIAL AND METHODS Sixty mandibular human molars were endodontically treated, prepared for endocrowns, and divided into 4 groups (n=15) according to the following various ceramic systems: leucite-based glass-ceramic (LC group), lithium disilicate-based glass-ceramic (LD group), glass-ceramic based on zirconia-reinforced lithium silicate (LSZ group), and monolithic zirconia (ZR group). After adhesive bonding, the specimens were subjected to thermomechanical loading and then to fracture resistance testing in a universal testing machine. The failure mode of the specimens was qualitatively evaluated. Three-dimensional FEA was performed to evaluate the stress distribution in each group. Data were analyzed by using a 1-way ANOVA and the Tukey HSD test (α=.05). RESULTS Statistically significant differences among the groups were observed (P<.05). The outcomes of the LC, LD, and LSZ groups were similar (1178 N, 1935 N, and 1859 N) but different from those of the ZR group (6333 N). The LC and LD groups had a higher ratio of restorable failures, while LSZ and ZR had more nonrestorable failures. Fractographic analysis indicated a regular failure pattern in the ZR group and irregular failure patterns in the other groups. Three-dimensional FEA revealed similar values and stress pattern distributions among the groups. CONCLUSIONS The mechanical performance of monolithic zirconia was better than that of the other ceramic endocrowns considered in this research; however, monolithic zirconia presented a higher rate of catastrophic tooth structure failure.
Collapse
Affiliation(s)
- Nereu Roque Dartora
- Postgraduate student, School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, Brazil
| | | | - Stephanie Francoi Poole
- Postgraduate student, School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, Brazil
| | - Ataís Bacchi
- Professsor, Meridional Faculty (IMED), School of Dentistry, Passo Fundo, Brazil
| | - Manoel Damião Sousa-Neto
- Professor, Department of Restorative Dentistry, Dental School of Ribeirão Preto, University of São Paulo (FORP-USP), Ribeirão Preto, Brazil
| | | | - Erica Alves Gomes
- Professor, School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, Brazil.
| |
Collapse
|
91
|
Vila-Nova TEL, Gurgel de Carvalho IH, Moura DMD, Batista AUD, Zhang Y, Paskocimas CA, Bottino MA, de Assunção E Souza RO. Effect of finishing/polishing techniques and low temperature degradation on the surface topography, phase transformation and flexural strength of ultra-translucent ZrO 2 ceramic. Dent Mater 2020; 36:e126-e139. [PMID: 32008750 DOI: 10.1016/j.dental.2020.01.004] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Revised: 11/24/2019] [Accepted: 01/14/2020] [Indexed: 01/25/2023]
Abstract
OBJECTIVE To investigate the effect of different surface finishing and polishing regimes and low temperature degradation on flexural strength, phase transformation and surface topography of ultra-translucent ZrO2 ceramic. METHODS 300 (n=15/group) of conventional zirconia (Z: Ice Zirkon Transluzent) and ultra-translucent zirconia (UT: Prettau Anterior) bar-specimens were made and divided according to the "Finishing/Polishing" - (C - Control, B - diamond rubber polishers, P - adjusting with burs, PB - adjusting with burs+diamond polishers, PG - adjusting with burs+glaze), "Low temperature Degradation (LTD)" (with or without a treatment at 127°C, 1.7bar/24h). Then, a 3-point mini flexural test was performed in a universal testing machine (1mm/min, 500kgf load cell). SEM, EDS, XDR, AFM, optical profilometry and Weibull analysis were performed. Data were analyzed by 3-way ANOVA and Tukey's post-test (5%). RESULTS Groups ZPBD (1670±253MPa), ZBD (1664±217MPa), and ZB (1655±3678MPa) showed significantly higher flexural strength than the UTPG group (372±56MPa). The Weibull modulus was significantly higher for the ZPD group compared to the UB, UCD, UPD and UPBD, while UTB, UTCD and UTPD had the lowest value. Monoclinic phases were observed only in the conventional zirconia groups and were more evident after LTD. Diamond rubber polishers presented less roughness for both zirconias. SIGNIFICANCE The use of diamond rubber polishers is the most suitable finishing/polishing method for zirconia ceramic restorations and that final glazing reduces the fracture resistance of these materials.
Collapse
Affiliation(s)
- Taciana Emília Leite Vila-Nova
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Av. Salgado Filho, 1787, Lagoa Nova, Natal, RN, CEP: 59056-000, Brazil.
| | - Isabelle Helena Gurgel de Carvalho
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Division of Prosthodontics, Av. Salgado Filho, 1787, Lagoa Nova, Natal, RN, 59056-000, Brazil.
| | - Dayanne Monielle Duarte Moura
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Division of Prosthodontics, Av. Salgado Filho, 1787, Lagoa Nova, Natal, RN, 59056-000, Brazil.
| | - André Ulisses Dantas Batista
- Federal University of Paraíba (UFPB), Department of Restorative Dentistry, Conj. Pres. Castelo Branco III, João Pessoa, PB, 58033-455, Brazil.
| | - Yu Zhang
- New York University College of Dentistry, Department of Biomaterials and Biomimetics, 433 First Avenue, Room 810, New York, NY, 10010, United States.
| | - Carlos Alberto Paskocimas
- Federal University of Rio Grande do Norte (UFRN), Department of Material Engineering, Av. Salgado Filho, 3000, Lagoa Nova, Natal, RN, Brazil.
| | - Marco Antonio Bottino
- São Paulo State University (UNESP), Institute of Science and Technology, Av Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, São José dos Campos, CEP: 12245-000, Brazil.
| | - Rodrigo Othávio de Assunção E Souza
- Adjunct Professor at Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Division of Prosthodontics, Av. Salgado Filho, 1787, Lagoa Nova, Natal, RN, 59056-000, Brazil.
| |
Collapse
|
92
|
Fontana PE, Bohrer TC, Wandscher VF, Valandro LF, Limberger IF, Kaizer OB. Effect of Ferrule Thickness on Fracture Resistance of Teeth Restored With a Glass Fiber Post or Cast Post. Oper Dent 2019; 44:E299-E308. [DOI: 10.2341/18-241-l] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Purpose:
To investigate the influence of ferrule thickness on fracture resistance after mechanical cycling of teeth restored with different intracanal posts.
Methods and Materials:
One hundred twenty bovine incisor teeth were randomized into six study groups, based on the intracanal post used (fiber post or cast post and core) and the presence and thickness of a ferrule (without ferrule, presence of 0.5-mm or 1-mm-thick ferrule, retaining unaltered 2-mm ferrule height). The root posts and the metal crowns were cemented using an adhesive cement. The samples were subjected to mechanical cycling (at 37°C, 45°, 130 N, 2.2 Hz, and 2 × 106 pulses). Afterward, they were subjected to a fracture load test at a speed of 0.5 mm/min and on a 45° slope until failure occurred. The failures were classified as favorable or unfavorable. The fracture resistance data were analyzed with two-way analysis of variance and Tukey test. The chi-square test was used to analyze the pattern of failure.
Results:
When considering the cast post and core, the 1-mm ferrule thickness group presented a higher resistance to fracture than did the group in which a ferrule was not used (p=0.001). When using a glass fiber post, the groups showed no differences in fracture resistance. Overall, 96.7% of the specimens survived the mechanical cycling. Of the fractures, 58.6% of the fractures were unfavorable, while 41.6% were favorable.
Conclusions:
A thicker ferrule statistically increased the fracture resistance only for cast post and core when it was at least 1 mm thick, despite causing more unfavorable failures. Thus, ferrule thickness should be considered when choosing different intracanal posts, to reduce the occurrence of unfavorable failures. In the absence of a ferrule, the use of a cast post and core presents more favorable failures, and in the presence of a 1-mm-thick ferrule, the use of a glass fiber post seems to be the best clinical decision.
Collapse
Affiliation(s)
- PE Fontana
- Patrícia Eliana Fontana, MSD, DDS graduate student in Oral Sciences (Prosthodontics), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| | - TC Bohrer
- Thaís Camponogara Bohrer, MSD, DDS graduate student in Oral Sciences (Prosthodontics), MSD, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| | - VF Wandscher
- Vinícius Felipe Wandscher, MSD, PhD, adjunct professor, Faculty of Odontology, Franciscan University (Prosthodontics Unit), Santa Maria, Brazil
| | - LF Valandro
- Luiz Felipe Valandro, MSD, PhD, associate professor, MDS Graduate Program in Oral Science (Prosthodontics-Biomaterials Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| | - IF Limberger
- Inácio F Limberger, PhD, associate professor, Faculty of Mechanical Engineering, Federal University of Santa Maria, Santa Maria, Brazil
| | - OB Kaizer
- Osvaldo Bazzan Kaizer, MSD, PhD, adjunct professor, MDS Graduate Program in Oral Science (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| |
Collapse
|
93
|
Tribst JPM, Dal Piva AMDO, Madruga CFL, Valera MC, Bresciani E, Bottino MA, de Melo RM. The impact of restorative material and ceramic thickness on CAD\CAM endocrowns. J Clin Exp Dent 2019; 11:e969-e977. [PMID: 31700569 PMCID: PMC6825739 DOI: 10.4317/jced.56002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 09/09/2019] [Indexed: 12/01/2022] Open
Abstract
Background Endocrown restorations as a conservative approach to restore endodontically treated teeth still need in vitro investigation under fatigue and made in different materials. This study evaluated the effect of restorative material and restoration thickness on the maximum fracture load of endocrowns subjected to cyclic loading. Material and Methods Sixty (60) third molar teeth received an endocrown preparation with three different heights of remaining dental tissue (1.5, 3.0 or 4.5 mm). A leucite-based ceramic (LEU) and a lithium disilicate (LD) based ceramic were selected to manufacture the CAD/CAM endocrown restorations, totaling 6 groups (n=10). The specimens were subjected to fatigue loading (200N, 2 x 106 cycles, water) and then to the single load to failure test (1 mm/min crosshead speed). Data were analyzed by using two-way ANOVA and Tukey tests (p< 0.05). Results All endocrowns survived the fatigue test. The thickness did not influence the restoration’s fracture load (p=0.548) instead the restorative material (p=0.003). LD showed higher mean values (1714.43 N)A than LEU (1313.47 N)B. Conclusions Endocrowns manufactured with CAD/CAM lithium disilicate blocks showed superior fracture load than the leucite-based blocks after mechanical fatigue. Nevertheless, both materials presented acceptable survival and fracture load as long as the material’s minimum thickness and the enamel adhesion are respected. Key words:Endocrown, CAD/CAM, Endodontically treated teeth, Failure load, Minimal intervention dentistry.
Collapse
Affiliation(s)
- João-Paulo-Mendes Tribst
- DDs, MSc, PhD Student in Prosthodontics, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| | - Amanda-Maria-de Oliveira Dal Piva
- DDs, MSc, PhD Student in Prosthodontics, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| | - Camila-Ferreira-Leite Madruga
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, n° 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Marcia-Carneiro Valera
- Department of Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, n° 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Eduardo Bresciani
- Department of Restorative Dentistry, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, n° 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Marco-Antonio Bottino
- DDs, MSc, PhD, Professor, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| | - Renata-Marques de Melo
- DDs, MSc, PhD, Researcher III, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| |
Collapse
|
94
|
Guilardi LF, Pereira GKR, Giordani JC, Kleverlaan CJ, Valandro LF, Rippe MP. Effect of zirconia surface treatment, resin cement and aging on the load-bearing capacity under fatigue of thin simplified full-contour Y-TZP restorations. J Mech Behav Biomed Mater 2019; 97:21-29. [DOI: 10.1016/j.jmbbm.2019.04.050] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 04/24/2019] [Accepted: 04/26/2019] [Indexed: 10/26/2022]
|
95
|
Suominen JM, Frankberg EJ, Vallittu PK, Levänen E, Vihinen J, Vastamäki T, Kari R, Lassila LVJ. Three-dimensional printing of zirconia: characterization of early stage material properties. Biomater Investig Dent 2019. [DOI: 10.1080/26415275.2019.1640608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
Affiliation(s)
- Jussi M. Suominen
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre - TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - Erkka J. Frankberg
- Materials Science and Environmental Engineering, Tampere University, Tampere, Finland
| | - Pekka K. Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre - TCBC, Institute of Dentistry, University of Turku, Turku, Finland
- City of Turku Welfare Division, University of Turku, Turku, Finland
| | - Erkki Levänen
- Materials Science and Environmental Engineering, Tampere University, Tampere, Finland
| | - Jorma Vihinen
- Automation Technology and Mechanical Engineering, Tampere University, Tampere, Finland
| | - Teemu Vastamäki
- Materials Science and Environmental Engineering, Tampere University, Tampere, Finland
| | - Risto Kari
- Materials Science and Environmental Engineering, Tampere University, Tampere, Finland
| | - Lippo V. J. Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre - TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| |
Collapse
|
96
|
Øilo M, Schriwer C, Flinn B, Gjerdet NR. Monolithic zirconia crowns – wall thickness, surface treatment and load at fracture. Biomater Investig Dent 2019. [DOI: 10.1080/26415275.2019.1642112] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
Affiliation(s)
- Marit Øilo
- Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Bergen, Norway
- Department of Materials Science and Engineering, University of Washington, Seattle, WA, USA
| | - Christian Schriwer
- Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Bergen, Norway
| | - Brian Flinn
- Department of Materials Science and Engineering, University of Washington, Seattle, WA, USA
| | - Nils Roar Gjerdet
- Department of Clinical Dentistry, Faculty of Medicine, University of Bergen, Bergen, Norway
| |
Collapse
|
97
|
Rohr N, Balmer M, Müller JA, Märtin S, Fischer J. Chewing simulation of zirconia implant supported restorations. J Prosthodont Res 2019; 63:361-367. [DOI: 10.1016/j.jpor.2019.02.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Revised: 02/01/2019] [Accepted: 02/13/2019] [Indexed: 11/28/2022]
|
98
|
Hampe R, Theelke B, Lümkemann N, Eichberger M, Stawarczyk B. Fracture Toughness Analysis of Ceramic and Resin Composite CAD/CAM Material. Oper Dent 2019; 44:E190-E201. [DOI: 10.2341/18-161-l] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objectives:
To evaluate and compare the fracture toughness of dental CAD/CAM materials of different material classes intended for in-office milling (glass ceramics, hybrid, resin composites) and the influence of aging on this property.
Methods and Materials:
The fracture toughness (critical intensity factor, KIc) values of 9 CAD/CAM restorative materials (Ambarino High-Class, Brilliant Crios, Cerasmart, exp. CAD/CAM composite, Katana Avencia, Lava Ultimate, VITA Enamic, IPS Empress CAD, and IPS e.max CAD) were determined using the SEVNB method in a four-point bending setup. Twenty bending bars of each material with a 4 × 3 cross and a minimum length of 12 mm were cut out of CAD/CAM milling blocks. Notching was done starting with a pre-cut and consecutive polishing and v-shaping with a razor blade, resulting in a final depth of v-shaped notches of between 0.8 and 1.2 mm. Half of the specimens were selected for initial fracture toughness measurements. The others were thermocycled in distilled water for 30,000× (5/55°C; 30-second dwell time) before testing. Specimen fracture surfaces were analyzed using confocal laser scanning microscopy.
Results:
All specimens for each material fractured into two fragments and showed the typical compression curl and brittle failure markings. Comparing initial KIc values, lithium disilicate ceramic IPS e.max CAD showed significantly the highest and leucite-reinforced ceramic IPS Empress CAD significantly the lowest KIc values (p<0.001). All tested CAD/CAM materials with a resin component ranged in the same KIc value group (p>0.999-0.060). After thermal cycling, the highest KIc values were measured for lithium disilicate ceramic IPS e.max CAD, followed by resin composite materials Ambarino High-Class (p<0.001-0.006) and hybrid material VITA Enamic (p<0.001-0.016), while the significantly lowest values were reflected for the resin composite materials Cerasmart, LAVA Ultimate (p<0.001-0.006), and Katana Avencia (p<0.001-0.009). The roughness of the fracture surfaces varied depending on the microstructure of the respective material. The ceramic surfaces showed the smoothest surfaces. The fracture surface of VITA Enamic revealed microstructural inhomogeneities and microcracks. For CAD/CAM resin composite materials, crack paths through the matrix and interfaces of matrix and fillers could be observed at the microstructure level.
Conclusions:
The materials tested show differences in fracture toughness typical for the class they belong to. With one exception (Ambarino High-Class), thermocycling affected the fracture toughness of materials with a resin component negatively, whereas the leucite and lithium disilicate ceramic showed stability.
Collapse
Affiliation(s)
- R Hampe
- Rüdiger Hampe, Dipl-Ing (FH), MSc, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - B Theelke
- Björn Theelke, Dipl-Ing (FH), School of Metallurgy and Materials, University of Birmingham, Birmingham, UK
| | - N Lümkemann
- Nina Lümkemann, MSc, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| | - M Eichberger
- Marlis Eichberger, CDT, Department of Prosthodontics, Dental School Ludwig-Maximilians-University, Munich, Germany
| | - B Stawarczyk
- Bogna Stawarczyk, PhD, Dr Dipl-Ing (FH), MSc, Department of Prosthetic Dentistry, University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
99
|
Alessandretti R, Ribeiro R, Borba M, Bona AD. Fracture Load and Failure Mode of CAD-on Ceramic Structures. Braz Dent J 2019; 30:380-384. [DOI: 10.1590/0103-6440201902574] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Accepted: 02/08/2019] [Indexed: 11/21/2022] Open
Abstract
Abstract This study evaluated the fracture load (Lf) and the failure mode of CAD-on (Ivoclar Vivadent) ceramic structures, testing the hypotheses that Lf of multilayer structures is governed by the veneering ceramic strength and that chipping is more frequent in multilayer than monolithic structures. Disc-shaped specimens were fabricated as follows: CAD-on- trilayer structure composed of Y-TZP (yttria stabilized tetragonal zirconia polycrystal- IPS e.max ZirCAD) infrastructure, fusion glass-ceramic (IPS e.max CAD Crystall/Connect) and lithium disilicate-based glass-ceramic (IPS e.max CAD); YLD- bilayer structure composed of Y-TZP infrastructure and fluorapatite layering ceramic (IPS e.max Ceram); LDC- monolithic lithium-disilicate glass-ceramic (IPS e.max CAD); and YZW- monolithic Y-TZP (Zenostar Zr Translucent). The specimens were loaded in compression until failure and fracture surfaces were evaluated using fractographic principles. Lf values were statistically analyzed using the Weibull statistics, Kruskal-Wallis and Dunn tests (a= 0.05). YZW (1329 N) and CAD-on (1085 N) showed the greatest Lf median values, followed by YLD (832 N) and LDC (421 N). All monolithic structures (LDC and YZW) fractured catastrophically and all YLD structures failed by chipping. The CAD-on technique seems to be a very promising fabrication process because it showed high Lf, similar to monolithic zirconia, and small chipping rate.
Collapse
|
100
|
van den Breemer C, Cune M, Özcan M, Naves L, Kerdijk W, Gresnigt M. Randomized clinical trial on the survival of lithium disilicate posterior partial restorations bonded using immediate or delayed dentin sealing after 3 years of function. J Dent 2019; 85:1-10. [DOI: 10.1016/j.jdent.2019.02.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 01/01/2019] [Accepted: 02/06/2019] [Indexed: 11/28/2022] Open
|