51
|
Gustave D, Mitchinson CJ, Succi PJ, Benitez B, Kwak M, Lanphere KR, Clasey JL, Bergstrom HC. Metabolic and Perceptual Responses to Constant Heart Rate Exercise at Vigorous Intensities in Women. Med Sci Sports Exerc 2024; 56:917-926. [PMID: 38233976 DOI: 10.1249/mss.0000000000003381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2024]
Abstract
PURPOSE This study quantified the metabolic demands (oxygen uptake (V̇O 2 )), power output adjustments, changes in the V̇O 2 /power output ratio, and perceptual responses (rating of perceived exertion (RPE)) during constant heart rate (HR) exercise performed within the vigorous intensity range (77%-95% HR peak ). METHODS Twelve women (mean ± SD age, 22 ± 4 yr) performed a graded exercise test to exhaustion to determine peak parameters, and three randomly ordered, constant HR trials to exhaustion or for 60 min at the lower (HR L = 77% HR peak ), middle (HR M = 86% HR peak ), and higher (HR H = 95% HR peak ) end of the vigorous intensity range. Time course of changes and patterns of responses were examined for V̇O 2 , power output, V̇O 2 /power output, and RPE for the composite and for each subject. RESULTS Across the HR L (time to exhaustion ( Tlim ) = 56.3 ± 9.9 min), HR M (51.8 ± 13.5 min), and HR H (27.2 ± 17.7 min) trials, V̇O 2 and power output decreased quadratically ( P < 0.05) relative to the initial value from 10% to 100% of Tlim , whereas the V̇O 2 /power output increased quadratically from 20% to 100% Tlim , and RPE increased linearly from 50% to 100% Tlim . The V̇O 2 and RPE, collapsed across time, for HR L (54.3% ± 3.3% V̇O 2peak , 11 ± 1.5 RPE) were lower than HR M (64.9% ± 4.5% V̇O 2peak , 14 ± 1.7 RPE), and both were lower than HR H (80.1% ± 4.1% V̇O 2peak , 17 ± 1.4 RPE). None of the 12 subjects at HR L , 6 at HR M , and 7 at HR H were within the vigorous V̇O 2 range. CONCLUSIONS The HR L was not sufficient to meet the desired metabolic intensity for vigorous exercise, whereas the middle to higher end of the range elicited a V̇O 2 within the prescribed range of only ~50%-60% of the subjects. This study indicated that exercise held constant at a percentage of HR peak cannot consistently be used to prescribe a desired metabolic stimulus.
Collapse
Affiliation(s)
- Djadmann Gustave
- Department of Kinesiology and Health Promotion, University of Kentucky, Lexington, KY
| | | | | | | | | | | | | | | |
Collapse
|
52
|
Peden DL, Rogers R, Mitchell EA, Taylor SM, Bailey SJ, Ferguson RA. Skeletal muscle mitochondrial correlates of critical power and W' in healthy active individuals. Exp Physiol 2024. [PMID: 38593224 DOI: 10.1113/ep091835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Accepted: 03/25/2024] [Indexed: 04/11/2024]
Abstract
The asymptote (critical power; CP) and curvature constant (W') of the hyperbolic power-duration relationship can predict performance within the severe-intensity exercise domain. However, the extent to which these parameters relate to skeletal muscle mitochondrial content and respiratory function is not known. Fifteen males (peak O2 uptake, 52.2 ± 8.7 mL kg-1 min-1; peak work rate, 366 ± 40 W; and gas exchange threshold, 162 ± 41 W) performed three to five constant-load tests to task failure for the determination of CP (246 ± 44 W) and W' (18.6 ± 4.1 kJ). Skeletal muscle biopsies were obtained from the vastus lateralis to determine citrate synthase (CS) activity, as a marker of mitochondrial content, and the ADP-stimulated respiration (P) and maximal electron transfer (E) through mitochondrial complexes (C) I-IV. The CP was positively correlated with CS activity (absolute CP, r = 0.881, P < 0.001; relative CP, r = 0.751, P = 0.001). The W' was not correlated with CS activity (P > 0.05). Relative CP was positively correlated with mass-corrected CI + IIE (r = 0.659, P = 0.038), with absolute CP being inversely correlated with CS activity-corrected CIVE (r = -0.701, P = 0.024). Relative W' was positively correlated with CS activity-corrected CI + IIP (r = 0.713, P = 0.021) and the phosphorylation control ratio (r = 0.661, P = 0.038). There were no further correlations between CP or W' and mitochondrial respiratory variables. These findings support the assertion that skeletal muscle mitochondrial oxidative capacity is positively associated with CP and that this relationship is strongly determined by mitochondrial content.
Collapse
Affiliation(s)
- Donald L Peden
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Robert Rogers
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Emma A Mitchell
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Suzanne M Taylor
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Stephen J Bailey
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Richard A Ferguson
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| |
Collapse
|
53
|
Langley JO, Langley B. The effect of advanced footwear technology on elite male marathon race speed. Eur J Appl Physiol 2024; 124:1143-1149. [PMID: 37922023 DOI: 10.1007/s00421-023-05341-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Accepted: 10/11/2023] [Indexed: 11/05/2023]
Abstract
PURPOSE The aim of this study was to explore the ergogenic effect of advanced footwear technology (AFT) upon world-class male marathon running speed. METHOD A retrospective analysis of 99 world-class male marathon runners' performances between 2012 and 2021 was undertaken, providing a sample size of 971 performances, split into two footwear groups: AFT (n = 299) and traditional (n = 672). Additionally, details regarding the year of the marathon performance and racecourse were extracted. A mixed model for repeated measures (MMRM) analysis were undertaken identifying athlete (Wald Z = 2.821; p = .005) and course (Wald Z = 4.111; p < 0.001) as significant contributors to the variance in marathon running speed and as such were included as random factors with footwear type set as a fixed factor. RESULTS World-class male marathon running speeds were significantly faster (p < 0.001) when running in AFT (5.441 m.s-1) when compared with traditional shoes (5.386 m.s-1) with a mean difference of 0.055 m.s-1 (95% CI 0.039-0.071 m.s-1), translating to an improvement in marathon speed of 1.0% or a 79 s improvement in marathon race time. CONCLUSION Our findings demonstrate an improvement in world-class male marathon running speed of 1% when running in AFT, a near identical degree of improvement to the male marathon world record ran in AFT. Whilst a 1% improvement in marathon running times associated with AFT is smaller than previously predicted utilizing laboratory-based models, this still reflects a significant degree of improvement at the elite level.
Collapse
Affiliation(s)
- Jamie Oliver Langley
- Department of Higher Education Sport, Loughborough College, Radmoor Road, Loughborough, Leicestershire, LE11 3BT, UK.
| | - Ben Langley
- Sport and Physical Activity, Edge Hill University, Ormskirk, Lancashire, L39 4QP, UK
| |
Collapse
|
54
|
Fekih N, Zghal F, Machfer A, Ben Hadj Hassen H, Zarizissi S, Bouzid MA. Peripheral fatigue regulation during knee extensor exercise in type 1 diabetes and consequences on the force-duration relationship. Eur J Appl Physiol 2024; 124:897-908. [PMID: 37733138 DOI: 10.1007/s00421-023-05318-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Accepted: 09/04/2023] [Indexed: 09/22/2023]
Abstract
PURPOSE This study aimed to examine if peripheral fatigue is adjusted during knee extensor (KE) exercise in order not to surpass a critical threshold patient with type 1 diabetes (T1D) and the consequences of this mechanism on the force-duration relationship. METHODS Eleven T1D individuals randomly performed two different sessions in which they performed 60 maximum voluntary contractions (MVC; 3 s contraction, 2 s relaxation). One trial was performed in the non-fatigued state (CTRL) and another after fatiguing neuromuscular stimulation of the KE (FNMES). Peripheral and central fatigue were quantified by the difference between pre and post exercise in quadriceps voluntary activation (ΔVA) and potentiated twitch (ΔPtw). Critical torque (CT) was determined as the average force of the last 12 contractions, whereas W' was calculated as the area above the CT. RESULTS Although FNMES led to a significant decrease in potentiated twitch (Ptw) before performing the 60-MVCs protocol (p < 0.05), ΔVA (∼ -7.5%), ΔPtw (∼ -39%), and CT (∼816 N) post-MVCs were similar between the two conditions. The difference in W' between CTRL and FNMES was correlated with the level of pre-fatigue induced in FNMES (r2 = 0.60). In addition, W' was correlated with ΔPtw (r2 = 0.62) in the CTRL session. CONCLUSION Correlative results in the present study indicate that regulating peripheral fatigue mechanisms at a critical threshold limit W'. Additionally, peripheral fatigue during KE exercise is limited to an individual threshold in T1D patients.
Collapse
Affiliation(s)
- Nadia Fekih
- Research Laboratory: Education, Motricité, Sport et Santé, EM2S, LR19JS01, High Institute of Sport and Physical Education, University of Sfax, Road of the Aerodrome, Km 3.5, BP 1068, 3000, Sfax, Tunisia
| | - Firas Zghal
- Faculté des Sciences du Sport, LAMHESS, Université Côte d'Azur, Nice, France
| | - Amal Machfer
- Research Laboratory: Education, Motricité, Sport et Santé, EM2S, LR19JS01, High Institute of Sport and Physical Education, University of Sfax, Road of the Aerodrome, Km 3.5, BP 1068, 3000, Sfax, Tunisia
| | - Hayfa Ben Hadj Hassen
- Research Laboratory: Education, Motricité, Sport et Santé, EM2S, LR19JS01, High Institute of Sport and Physical Education, University of Sfax, Road of the Aerodrome, Km 3.5, BP 1068, 3000, Sfax, Tunisia
| | - Slim Zarizissi
- Research Laboratory: Education, Motricité, Sport et Santé, EM2S, LR19JS01, High Institute of Sport and Physical Education, University of Sfax, Road of the Aerodrome, Km 3.5, BP 1068, 3000, Sfax, Tunisia
| | - Mohamed Amine Bouzid
- Research Laboratory: Education, Motricité, Sport et Santé, EM2S, LR19JS01, High Institute of Sport and Physical Education, University of Sfax, Road of the Aerodrome, Km 3.5, BP 1068, 3000, Sfax, Tunisia.
| |
Collapse
|
55
|
Short T, Yamada PM. Maximal Running Speed and Critical Speed Are Positively Related to Phase Angle in Healthy Young Adults. INTERNATIONAL JOURNAL OF EXERCISE SCIENCE 2024; 17:405-417. [PMID: 38665855 PMCID: PMC11042853 DOI: 10.70252/ythn9269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 03/15/2025]
Abstract
Phase Angle (PhA), derived from bioelectrical impedance analysis, is a measurement of cellular resistance to electrical current and a non-invasive tool to monitor neuromuscular performance. The relationship between PhA and components of athletic performance is not fully understood. The purpose of this study was to determine if maximal running speed, critical speed (CS), and/or D prime (D') derived from a 3-minute all-out-test (3MAOT) correlates to PhA, reactance (Xc), or resistance (R). Sixty-one (male n=35, female n=26) healthy young adults (23.4±3.9 years) completed bioelectrical impedance analysis (Inbody770) and a 3MAOT. The correlations between PhA, Xc, and R and 3MAOT results were evaluated using correlations. Simple and multiple linear-regressions were used to test if results from the 3MAOT (maximum running speed, CS, D') could predict PhA. Linear regression analysis indicated that maximum running speed and CS alone explained 32% and 9% of the variance in PhA, respectively (R2=0.32, p<0.05; R2=0.09, p<0.05). Multiple linear regression indicated that maximum running speed, CS, and D' explained 35% of the variance in PhA (R2=0.35; p<0.05). Only maximum running speed remained a significant predictor of PhA after controlling for age (β=0.45; p<0.05), but not after controlling for both age and sex (β=0.14; p>0.05). Since maximum running speed was a stronger predictor of PhA compared to CS (proxy for endurance performance), practitioners should use discernment when using PhA as a readiness tool to monitor endurance performance.
Collapse
Affiliation(s)
- Trevor Short
- Human Performance Laboratory, Department of Kinesiology & Rehabilitation Science, University of Hawai'i-Mānoa, Honolulu, HI, USA
| | - Paulette M Yamada
- Human Performance Laboratory, Department of Kinesiology & Rehabilitation Science, University of Hawai'i-Mānoa, Honolulu, HI, USA
| |
Collapse
|
56
|
Bowen M, Samozino P, Vonderscher M, Dutykh D, Morel B. Mathematical modeling of exercise fatigability in the severe domain: A unifying integrative framework in isokinetic condition. J Theor Biol 2024; 578:111696. [PMID: 38070705 DOI: 10.1016/j.jtbi.2023.111696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 11/15/2023] [Accepted: 12/04/2023] [Indexed: 12/22/2023]
Abstract
Muscle fatigue is the decay in the ability of muscles to generate force, and results from neural and metabolic perturbations. This article presents an integrative mathematical model that describes the decrease in maximal force capacity (i.e. fatigue) over exercises performed at intensities above the critical force Fc (i.e. severe domain). The model unifies the previous Critical Power Model and All-Out Model and can be applied to any exercise described by a changing force F over time. The assumptions of the model are (i) isokinetic conditions, an intensity domain of Fc
Collapse
Affiliation(s)
- M Bowen
- Laboratoire Interuniversitaire de Biologie de la Motricité LIBM, EA 7424, Savoie Mont Blanc University, F-7300, Chambéry, France.
| | - P Samozino
- Laboratoire Interuniversitaire de Biologie de la Motricité LIBM, EA 7424, Savoie Mont Blanc University, F-7300, Chambéry, France
| | - M Vonderscher
- Laboratoire Interuniversitaire de Biologie de la Motricité LIBM, EA 7424, Savoie Mont Blanc University, F-7300, Chambéry, France
| | - D Dutykh
- Mathematics Department, Khalifa University of Science and Technology, PO Box 127788, Abu Dhabi, United Arab Emirates; Causal Dynamics Pty Ltd, WA 6009, Perth, Australia
| | - B Morel
- Laboratoire Interuniversitaire de Biologie de la Motricité LIBM, EA 7424, Savoie Mont Blanc University, F-7300, Chambéry, France
| |
Collapse
|
57
|
Bartlett MF, Fitzgerald LF, Nagarajan R, Kent JA. Measurements of in vivo skeletal muscle oxidative capacity are lower following sustained isometric compared with dynamic contractions. Appl Physiol Nutr Metab 2024; 49:250-264. [PMID: 37906958 DOI: 10.1139/apnm-2023-0315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2023]
Abstract
Human skeletal muscle oxidative capacity can be quantified non-invasively using 31-phosphorus magnetic resonance spectroscopy (31P-MRS) to measure the rate constant of phosphocreatine (PCr) recovery (kPCr) following contractions. In the quadricep muscles, several studies have quantified kPCr following 24-30 s of sustained maximal voluntary isometric contraction (MVIC). This approach has the advantage of simplicity but is potentially problematic because sustained MVICs inhibit perfusion, which may limit muscle oxygen availability or increase the intracellular metabolic perturbation, and thus affect kPCr. Alternatively, dynamic contractions allow reperfusion between contractions, which may avoid limitations in oxygen delivery. To determine whether dynamic contraction protocols elicit greater kPCr than sustained MVIC protocols, we used a cross-sectional design to compare quadriceps kPCr in 22 young and 11 older healthy adults following 24 s of maximal voluntary: (1) sustained MVIC and (2) dynamic (MVDC; 120°·s-1, 1 every 2 s) contractions. Muscle kPCr was ∼20% lower following the MVIC protocol compared with the MVDC protocol (p ≤ 0.001), though this was less evident in older adults (p = 0.073). Changes in skeletal muscle pH (p ≤ 0.001) and PME accumulation (p ≤ 0.001) were greater following the sustained MVIC protocol, and pH (p ≤ 0.001) and PME (p ≤ 0.001) recovery were slower. These results demonstrate that (i) a brief, sustained MVIC yields a lower value for skeletal muscle oxidative capacity than an MVDC protocol of similar duration and (ii) this difference may not be consistent across populations (e.g., young vs. old). Thus, the potential effect of contraction protocol on comparisons of kPCr in different study groups requires careful consideration in the future.
Collapse
Affiliation(s)
- Miles F Bartlett
- Department of KinesiologyMuscle Physiology Laboratory, University of Massachusetts Amherst, MA 01003, USA
| | - Liam F Fitzgerald
- Department of KinesiologyMuscle Physiology Laboratory, University of Massachusetts Amherst, MA 01003, USA
| | - Rajakumar Nagarajan
- Human Magnetic Resonance Center, Institute for Applied Life Sciences (IALS), University of Massachusetts Amherst, MA 01003, USA
| | - Jane A Kent
- Department of KinesiologyMuscle Physiology Laboratory, University of Massachusetts Amherst, MA 01003, USA
| |
Collapse
|
58
|
Dorff A, Bradford C, Hunsaker A, Atkinson J, Rhees J, Leach OK, Gifford JR. Vascular dysfunction and the age-related decline in critical power. Exp Physiol 2024; 109:240-254. [PMID: 37934136 PMCID: PMC10988715 DOI: 10.1113/ep091571] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 10/18/2023] [Indexed: 11/08/2023]
Abstract
Ageing results in lower exercise tolerance, manifested as decreased critical power (CP). We examined whether the age-related decrease in CP occurs independently of changes in muscle mass and whether it is related to impaired vascular function. Ten older (63.1 ± 2.5 years) and 10 younger (24.4 ± 4.0 years) physically active volunteers participated. Physical activity was measured with accelerometry. Leg muscle mass was quantified with dual X-ray absorptiometry. The CP and maximum power during a graded exercise test (PGXT ) of single-leg knee-extension exercise were determined over the course of four visits. During a fifth visit, vascular function of the leg was assessed with passive leg movement (PLM) hyperaemia and leg blood flow and vascular conductance during knee-extension exercise at 10 W, 20 W, slightly below CP (90% CP) and PGXT . Despite not differing in leg lean mass (P = 0.901) and physical activity (e.g., steps per day, P = 0.735), older subjects had ∼30% lower mass-specific CP (old = 3.20 ± 0.94 W kg-1 vs. young = 4.60 ± 0.87 W kg-1 ; P < 0.001). The PLM-induced hyperaemia and leg blood flow and/or conductance were blunted in the old at 20 W, 90% CP and PGXT (P < 0.05). When normalized for leg muscle mass, CP was strongly correlated with PLM-induced hyperaemia (R2 = 0.52; P < 0.001) and vascular conductance during knee-extension exercise at 20 W (R2 = 0.34; P = 0.014) and 90% CP (R2 = 0.39; P = 0.004). In conclusion, the age-related decline in CP is not only an issue of muscle quantity, but also of impaired muscle quality that corresponds to impaired vascular function.
Collapse
Affiliation(s)
- Abigail Dorff
- Department of Exercise SciencesBrigham Young UniversityProvoUtahUSA
- Program of GerontologyBrigham Young UniversityProvoUtahUSA
| | - Christy Bradford
- Department of Exercise SciencesBrigham Young UniversityProvoUtahUSA
| | - Ashley Hunsaker
- Department of Exercise SciencesBrigham Young UniversityProvoUtahUSA
| | - Jake Atkinson
- Department of Exercise SciencesBrigham Young UniversityProvoUtahUSA
| | - Joshua Rhees
- Department of Exercise SciencesBrigham Young UniversityProvoUtahUSA
| | - Olivia K. Leach
- Department of Exercise SciencesBrigham Young UniversityProvoUtahUSA
- Program of GerontologyBrigham Young UniversityProvoUtahUSA
| | - Jayson R. Gifford
- Department of Exercise SciencesBrigham Young UniversityProvoUtahUSA
- Program of GerontologyBrigham Young UniversityProvoUtahUSA
| |
Collapse
|
59
|
Drake JP, Finke A, Ferguson RA. Modelling human endurance: power laws vs critical power. Eur J Appl Physiol 2024; 124:507-526. [PMID: 37563307 PMCID: PMC10858092 DOI: 10.1007/s00421-023-05274-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Accepted: 07/05/2023] [Indexed: 08/12/2023]
Abstract
The power-duration relationship describes the time to exhaustion for exercise at different intensities. It is believed to be a "fundamental bioenergetic property of living systems" that this relationship is hyperbolic. Indeed, the hyperbolic (a.k.a. critical-power) model which formalises this belief is the dominant tool for describing and predicting high-intensity exercise performance, e.g. in cycling, running, rowing or swimming. However, the hyperbolic model is now the focus of a heated debate in the literature because it unrealistically represents efforts that are short (< 2 min) or long (> 15 min). We contribute to this debate by demonstrating that the power-duration relationship is more adequately represented by an alternative, power-law model. In particular, we show that the often-observed good fit of the hyperbolic model between 2 and 15 min should not be taken as proof that the power-duration relationship is hyperbolic. Rather, in this range, a hyperbolic function just happens to approximate a power law fairly well. We also prove mathematical results which suggest that the power-law model is a safer tool for pace selection than the hyperbolic model and that the former more naturally models fatigue than the latter.
Collapse
Affiliation(s)
- Jonah P Drake
- Department of Mathematical Sciences, School of Science, Loughborough University, Loughborough, LE11 3TU, UK.
| | - Axel Finke
- Department of Mathematical Sciences, School of Science, Loughborough University, Loughborough, LE11 3TU, UK
| | - Richard A Ferguson
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, LE11 3TU, UK
| |
Collapse
|
60
|
Tripp TR, McDougall RM, Frankish BP, Wiley JP, Lun V, MacInnis MJ. Contraction intensity affects NIRS-derived skeletal muscle oxidative capacity but not its relationships to mitochondrial protein content or aerobic fitness. J Appl Physiol (1985) 2024; 136:298-312. [PMID: 38059287 DOI: 10.1152/japplphysiol.00342.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 11/16/2023] [Accepted: 12/02/2023] [Indexed: 12/08/2023] Open
Abstract
To further refine the near-infrared spectroscopy (NIRS)-derived measure of skeletal muscle oxidative capacity in humans, we sought to determine whether the exercise stimulus intensity affected the τ value and/or influenced the magnitude of correlations with in vitro measures of mitochondrial content and in vivo indices of exercise performance. Males (n = 12) and females (n = 12), matched for maximal aerobic fitness per fat-free mass, completed NIRS-derived skeletal muscle oxidative capacity tests for the vastus lateralis following repeated contractions at 40% (τ40) and 100% (τ100) of maximum voluntary contraction, underwent a skeletal muscle biopsy of the same muscle, and performed multiple intermittent isometric knee extension tests to task failure to establish critical torque (CT). The value of τ100 (34.4 ± 7.0 s) was greater than τ40 (24.2 ± 6.9 s, P < 0.001), but the values were correlated (r = 0.688; P < 0.001). The values of τ40 (r = -0.692, P < 0.001) and τ100 (r = -0.488, P = 0.016) correlated with myosin heavy chain I percentage and several markers of mitochondrial content, including COX II protein content in whole muscle (τ40: r = -0.547, P = 0.006; τ100: r = -0.466, P = 0.022), type I pooled fibers (τ40: r = -0.547, P = 0.006; τ100: r = -0.547, P = 0.006), and type II pooled fibers (τ40: r = -0.516, P = 0.009; τ100: r = -0.635, P = 0.001). The value of τ40 (r = -0.702, P < 0.001), but not τ100 (r = -0.378, P = 0.083) correlated with critical torque (CT); however, neither value correlated with W' (τ40: r = 0.071, P = 0.753; τ100: r = 0.054, P = 0.812). Overall, the NIRS method of assessing skeletal muscle oxidative capacity is sensitive to the intensity of skeletal muscle contraction but maintains relationships to whole body fitness, isolated limb critical intensity, and mitochondrial content regardless of intensity.NEW & NOTEWORTHY Skeletal muscle oxidative capacity measured using near-infrared spectroscopy (NIRS) was lower following high-intensity compared with low-intensity isometric knee extension contractions. At both intensities, skeletal muscle oxidative capacity was correlated with protein markers of mitochondrial content (in whole muscle and pooled type I and type II muscle fibers) and critical torque. These findings highlight the importance of standardizing contraction intensity while using the NIRS method with isometric contractions and further demonstrate its validity.
Collapse
Affiliation(s)
- Thomas R Tripp
- Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
| | | | | | - J Preston Wiley
- Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
- Faculty of Kinesiology, University of Calgary Sport Medicine Centre, Calgary, Alberta, Canada
| | - Victor Lun
- Faculty of Kinesiology, University of Calgary Sport Medicine Centre, Calgary, Alberta, Canada
| | - Martin J MacInnis
- Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
61
|
Berger NJA, Best R, Best AW, Lane AM, Millet GY, Barwood M, Marcora S, Wilson P, Bearden S. Limits of Ultra: Towards an Interdisciplinary Understanding of Ultra-Endurance Running Performance. Sports Med 2024; 54:73-93. [PMID: 37751076 DOI: 10.1007/s40279-023-01936-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/05/2023] [Indexed: 09/27/2023]
Abstract
Ultra-endurance running (UER) poses extreme mental and physical challenges that present many barriers to completion, let alone performance. Despite these challenges, participation in UER events continues to increase. With the relative paucity of research into UER training and racing compared with traditional endurance running distance (e.g., marathon), it follows that there are sizable improvements still to be made in UER if the limitations of the sport are sufficiently understood. The purpose of this review is to summarise our current understanding of the major limitations in UER. We begin with an evolutionary perspective that provides the critical background for understanding how our capacities, abilities and limitations have come to be. Although we show that humans display evolutionary adaptations that may bestow an advantage for covering large distances on a daily basis, these often far exceed the levels of our ancestors, which exposes relative limitations. From that framework, we explore the physiological and psychological systems required for running UER events. In each system, the factors that limit performance are highlighted and some guidance for practitioners and future research are shared. Examined systems include thermoregulation, oxygen delivery and utilisation, running economy and biomechanics, fatigue, the digestive system, nutritional and psychological strategies. We show that minimising the cost of running, damage to lower limb tissue and muscle fatigability may become crucial in UER events. Maintaining a sustainable core body temperature is critical to performance, and an even pacing strategy, strategic heat acclimation and individually calculated hydration all contribute to sustained performance. Gastrointestinal issues affect almost every UER participant and can be due to a variety of factors. We present nutritional strategies for different event lengths and types, such as personalised and evidence-based approaches for varying types of carbohydrate, protein and fat intake in fluid or solid form, and how to avoid flavour fatigue. Psychology plays a vital role in UER performance, and we highlight the need to be able to cope with complex situations, and that specific long and short-term goal setting improves performance. Fatigue in UER is multi-factorial, both physical and mental, and the perceived effort or level of fatigue have a major impact on the ability to continue at a given pace. Understanding the complex interplay of these limitations will help prepare UER competitors for the different scenarios they are likely to face. Therefore, this review takes an interdisciplinary approach to synthesising and illuminating limitations in UER performance to assist practitioners and scientists in making informed decisions in practice and applicable research.
Collapse
Affiliation(s)
- Nicolas J A Berger
- School of Health and Life Sciences, Teesside University, Middlesbrough, UK.
| | - Russ Best
- Centre for Sport Science and Human Performance, Wintec, Hamilton, New Zealand
| | - Andrew W Best
- Department of Biology, Massachusetts College of Liberal Arts, North Adams, MA, USA
| | - Andrew M Lane
- Faculty of Education Health and Wellbeing, University of Wolverhampton, Walsall, UK
| | - Guillaume Y Millet
- Univ Lyon, UJM Saint-Etienne, Inter-University Laboratory of Human Movement Biology, Saint Etienne, France
- Institut Universitaire de France (IUF), Paris, France
| | - Martin Barwood
- Department of Sport, Health and Nutrition, Leeds Trinity University Horsforth, Leeds, UK
| | - Samuele Marcora
- Department of Biomedical and Neuromotor Sciences, University of Bologna, Bologna, Italy
| | - Patrick Wilson
- Department of Human Movement Sciences, Old Dominion University, Norfolk, VA, USA
| | - Shawn Bearden
- Department of Biological Sciences, Idaho State University, Pocatello, ID, USA
| |
Collapse
|
62
|
Scott BE, Burden R, Dekerle J. Stroke-Specific Swimming Critical Speed Testing: Balancing Feasibility and Scientific Rigour. J Hum Kinet 2024; 90:239-251. [PMID: 38380294 PMCID: PMC10875687 DOI: 10.5114/jhk/170882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 08/09/2022] [Indexed: 02/22/2024] Open
Abstract
This study aimed to assess the reliability of a two-distance critical speed protocol in the specialist strokes of national-level swimmers and understand the practical feasibility of extending the protocol to increase its validity. Thirty-two national-level swimmers (butterfly n = 7; backstroke n = 8; breaststroke n = 7; front crawl n = 10) swum three 200-m and three 400-m performance trials over a three-week period. Critical speed and supra-critical speed distance capacity were computed from the linear modelling of the distance-time relationship. Swimmers were subsequently asked whether they felt they could or would want to complete an 800-m trial as part of a three-distance critical speed protocol to enhance validity. Both 200-m and 400-m performances (coefficient of variation of < 2%) and derived critical speed (typical error of ≤ 0.04 m·s-1; coefficient of variation of < 4%) were reliable for all strokes, while supra-critical speed distance capacity (typical error from 4 to 9 m; coefficient of variation from 13 to 45%) was not reliable. Response rates to the follow-up questions were 100%. Few butterfly swimmers said they felt they could complete an 800-m performance trial (39%), with more positive responses for breaststroke (71%), backstroke (100%), and front crawl swimmers (100%). Butterfly swimmers were significantly less likely to say they could or would want to complete an 800-m trial than backstroke and front crawl swimmers (p < 0.05). Including a third distance 800-m trial to increase critical speed validity would not be acceptable to butterfly swimmers, would be challenging to breaststroke swimmers, but would be acceptable to front crawl and backstroke swimmers.
Collapse
Affiliation(s)
- Ben E. Scott
- Fatigue and Exercise Laboratory, School of Sport and Health Sciences, University of Brighton, Eastbourne, UK
- English Institute of Sport, Loughborough University, Loughborough, UK
- British Swimming, Loughborough University, Loughborough, UK
| | - Richard Burden
- English Institute of Sport, Loughborough University, Loughborough, UK
- School of Sport, Exercise and Health Sciences, National Centre for Sport and Exercise Medicine, Loughborough University, Loughborough, UK
- School of Sport, Health and Applied Science, St Mary’s University, Twickenham, UK
| | - Jeanne Dekerle
- Fatigue and Exercise Laboratory, School of Sport and Health Sciences, University of Brighton, Eastbourne, UK
| |
Collapse
|
63
|
van Rassel CR, Sales KM, Ajayi OO, Nagai K, MacInnis MJ. A Comparison of Critical Speed and Critical Power in Runners Using Stryd Running Power. Int J Sports Physiol Perform 2024; 19:84-87. [PMID: 37898480 DOI: 10.1123/ijspp.2023-0260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 09/05/2023] [Accepted: 09/30/2023] [Indexed: 10/30/2023]
Abstract
PURPOSE Although running traditionally relies on critical speed (CS) as an indicator of critical intensity, portable inertial measurement units offer a potential solution for estimating running mechanical power to assess critical power (CP) in runners. The purpose of this study was to determine whether CS and CP differ when assessed using the Stryd device, a portable inertial measurement unit, and if 2 running bouts are sufficient to determine CS and CP. METHODS On an outdoor running track, 10 trained runners (V˙O2max, 59.0 [4.2] mL·kg-1·min-1) performed 3 running time trials (TT) between 1200 and 4400 m on separate days. CS and CP were derived from 2-parameter hyperbolic speed-time and power-time models, respectively, using 2 (CS2TT and CP2TT) and 3 (CS3TT and CP3TT) TTs. Subsequently, runners performed constant-intensity running for 800 m at their calculated CS3TT and CP3TT. RESULTS Running at the calculated CS3TT speed (3.88 [0.44] m·s-1) elicited an average Stryd running power (271 [28] W) not different from the calculated CP3TT (270 [28]; P = .940; d = 0.02), with excellent agreement between the 2 values (intraclass correlation coefficient = .980). The CS2TT (3.97 [0.42] m·s-1) was not higher than CS3TT (3.89 [0.44] m·s-1; P = .178; d = 0.46); however, CP2TT (278 [29] W) was greater than CP3TT (P = .041; d = 0.75). CONCLUSION The running intensities at CS and CP were similar, supporting the use of running power (Stryd) as a metric of aerobic fitness and exercise prescription, and 2 trials provided a reasonable, albeit higher, estimate of CS and CP.
Collapse
Affiliation(s)
| | - Kate M Sales
- Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| | | | - Koki Nagai
- Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada
| | | |
Collapse
|
64
|
Vrdoljak D, Foretić N, Drviš I, Ivančev V, Perić M, Dujić Ž. Do freedivers and spearfishermen differ in local muscle oxygen saturation and anaerobic power? J Sports Med Phys Fitness 2024; 64:21-29. [PMID: 37902796 DOI: 10.23736/s0022-4707.23.15185-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2023]
Abstract
BACKGROUND Freediving is defined as an activity where athletes repetitively dive and are exposed to long efforts with limited oxygen consumption. Therefore, anaerobic features are expected to be an important facet of diving performance. This study aimed to investigate differences in anaerobic capacity and local muscle oxygenation in spearfisherman and freedivers. METHODS The sample of participants included 17 male athletes (nine freedivers, and eight spearfishermen), with an average age of 37.0±8.8 years, training experience of 10.6±9.5 years, body mass of 82.5±9.5 kg and height of 184.2±5.7 cm. Anthropometric characteristics included: body mass, body height, seated height, and body fat percentage. Wingate anaerobic test was conducted, during which local muscle oxygenation was measured with a NIRS device (Moxy monitor). Wingate power outputs were measured (peak power [W/kg] and average power [W/kg]), together with muscle oxygenation variables (baseline oxygen saturation [%], desaturation slope [%/s], minimum oxygen saturation [%], half time recovery [s], and maximum oxygen saturation [%]). RESULTS The differences were not obtained between freedivers and spearfisherman in power outputs (peak power (9.24±2.08 spearfisherman; 10.68±1.04 freedivers; P=0.14); average power (6.85±0.95 spearfisherman; 7.44±0.60 freedivers; P=0.15) and muscle oxygenation parameters. However, analysis of effect size showed a moderate effect in training experience (0.71), PP (0.89), AP (0.75), Desat slope mVLR (0.66), half time recovery mVLR (0.90). CONCLUSIONS The non-existence of differences between freedivers and spearfishermen indicates similar training adaptations to the anaerobic demands. However, the results show relatively low anaerobic capacities of our divers that could serve as an incentive for the further development of these mechanisms.
Collapse
Affiliation(s)
- Dario Vrdoljak
- Faculty of Kinesiology, University of Split, Split, Croatia -
| | - Nikola Foretić
- Faculty of Kinesiology, University of Split, Split, Croatia
- High Performance Sport Center, Croatian Olympic Committee, Zagreb, Croatia
| | - Ivan Drviš
- Faculty of Kinesiology, University of Zagreb, Zagreb, Croatia
| | | | - Mia Perić
- Faculty of Kinesiology, University of Split, Split, Croatia
| | - Željko Dujić
- School of Medicine, University of Split, Split, Croatia
| |
Collapse
|
65
|
Short T, Stickley C, Freemyer B, Takata A, Yamada PM. Stance Time and Impact Loading Rates are Significant Predictors of Critical Speed During a 3-Minute All-Out Running Test. INTERNATIONAL JOURNAL OF EXERCISE SCIENCE 2024; 17:115-128. [PMID: 38665850 PMCID: PMC11042890 DOI: 10.70252/uutg9352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 03/15/2025]
Abstract
The addition of wearable technology during a 3-minute all-out overground running test (3MAOT) could provide additional insights to guide training and coaching strategies. The purpose of this study was to explore the relationships between critical speed (CS) and biomechanical parameters (cadence, stride length, vertical oscillation, stance time, form power, leg spring stiffness, and impact loading rate), and changes in biomechanical parameters throughout the 3MAOT. Sixty-three (male, n=37, female, n=26) recreationally active college-aged (23.4±3.9 years) subjects completed a 3MAOT while wearing a Stryd foot-pod. The correlations between CS and biomechanical parameters were evaluated using Pearson coefficients. Stepwise multiple linear regressions were used to test if biomechanical parameters could predict CS. Stance time and impact loading rate explained 69% and 63% of the variance in CS, respectively (R2=0.69, p<0.05; R2=0.63, p<0.05). Step-wise multiple linear regression analysis indicated that vertical oscillation, stance time, form power, leg spring stiffness, and impact loading rate explained 90% of the variance in CS (R2=0.90, p<0.05). Throughout the 3MAOT, changes in cadence (-29%), stride length (57%), vertical oscillation (-8%), stance time (82%), form power (-5%), leg spring stiffness (-24%), and impact loading rate (-48%) were observed. Interventions such as auditory cueing or training designed to improve CS should focus on maintaining large impact loading rates and short stance times, and efforts should be made to enhance an athlete's ability to maintain cadence, leg spring stiffness, vertical oscillation, and form power throughout the 3MAOT.
Collapse
Affiliation(s)
- Trevor Short
- Human Performance Laboratory, Department of Kinesiology & Rehabilitation Science, University of Hawai'i-Mānoa, Honolulu, HI, USA
| | - Christopher Stickley
- Human Performance Laboratory, Department of Kinesiology & Rehabilitation Science, University of Hawai'i-Mānoa, Honolulu, HI, USA
| | - Bret Freemyer
- Human Performance Laboratory, Department of Kinesiology & Rehabilitation Science, University of Hawai'i-Mānoa, Honolulu, HI, USA
| | - Andrew Takata
- Human Performance Laboratory, Department of Kinesiology & Rehabilitation Science, University of Hawai'i-Mānoa, Honolulu, HI, USA
| | - Paulette M Yamada
- Human Performance Laboratory, Department of Kinesiology & Rehabilitation Science, University of Hawai'i-Mānoa, Honolulu, HI, USA
| |
Collapse
|
66
|
Behnia M, Sietsema KE. Utility of Cardiopulmonary Exercise Testing in Chronic Obstructive Pulmonary Disease: A Review. Int J Chron Obstruct Pulmon Dis 2023; 18:2895-2910. [PMID: 38089541 PMCID: PMC10710955 DOI: 10.2147/copd.s432841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 10/17/2023] [Indexed: 12/18/2023] Open
Abstract
Chronic obstructive pulmonary disease (COPD) is a disease defined by airflow obstruction with a high morbidity and mortality and significant economic burden. Although pulmonary function testing is the cornerstone in diagnosis of COPD, it cannot fully characterize disease severity or cause of dyspnea because of disease heterogeneity and variable related and comorbid conditions affecting cardiac, vascular, and musculoskeletal systems. Cardiopulmonary exercise testing (CPET) is a valuable tool for assessing physical function in a wide range of clinical conditions, including COPD. Familiarity with measurements made during CPET and its potential to aid in clinical decision-making related to COPD can thus be useful to clinicians caring for this population. This review highlights pulmonary and extrapulmonary impairments that can contribute to exercise limitation in COPD. Key elements of CPET are identified with an emphasis on measurements most relevant to COPD. Finally, clinical applications of CPET demonstrated to be of value in the COPD setting are identified. These include quantifying functional capacity, differentiating among potential causes of symptoms and limitation, prognostication and risk assessment for operative procedures, and guiding exercise prescription.
Collapse
Affiliation(s)
- Mehrdad Behnia
- Pulmonary and Critical Care, University of Central Florida, Orlando, FL, USA
| | - Kathy E Sietsema
- The Lundquist Institute for Biomedical Innovation, Harbor-UCLA Medical Center, Torrance, CA, USA
| |
Collapse
|
67
|
Coates AM, Joyner MJ, Little JP, Jones AM, Gibala MJ. A Perspective on High-Intensity Interval Training for Performance and Health. Sports Med 2023; 53:85-96. [PMID: 37804419 PMCID: PMC10721680 DOI: 10.1007/s40279-023-01938-6] [Citation(s) in RCA: 49] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/12/2023] [Indexed: 10/09/2023]
Abstract
Interval training is a simple concept that refers to repeated bouts of relatively hard work interspersed with recovery periods of easier work or rest. The method has been used by high-level athletes for over a century to improve performance in endurance-type sports and events such as middle- and long-distance running. The concept of interval training to improve health, including in a rehabilitative context or when practiced by individuals who are relatively inactive or deconditioned, has also been advanced for decades. An important issue that affects the interpretation and application of interval training is the lack of standardized terminology. This particularly relates to the classification of intensity. There is no common definition of the term "high-intensity interval training" (HIIT) despite its widespread use. We contend that in a performance context, HIIT can be characterized as intermittent exercise bouts performed above the heavy-intensity domain. This categorization of HIIT is primarily encompassed by the severe-intensity domain. It is demarcated by indicators that principally include the critical power or critical speed, or other indices, including the second lactate threshold, maximal lactate steady state, or lactate turnpoint. In a health context, we contend that HIIT can be characterized as intermittent exercise bouts performed above moderate intensity. This categorization of HIIT is primarily encompassed by the classification of vigorous intensity. It is demarcated by various indicators related to perceived exertion, oxygen uptake, or heart rate as defined in authoritative public health and exercise prescription guidelines. A particularly intense variant of HIIT commonly termed "sprint interval training" can be distinguished as repeated bouts performed with near-maximal to "all out" effort. This characterization coincides with the highest intensity classification identified in training zone models or exercise prescription guidelines, including the extreme-intensity domain, anaerobic speed reserve, or near-maximal to maximal intensity classification. HIIT is considered an essential training component for the enhancement of athletic performance, but the optimal intensity distribution and specific HIIT prescription for endurance athletes is unclear. HIIT is also a viable method to improve cardiorespiratory fitness and other health-related indices in people who are insufficiently active, including those with cardiometabolic diseases. Research is needed to clarify responses to different HIIT strategies using robust study designs that employ best practices. We offer a perspective on the topic of HIIT for performance and health, including a conceptual framework that builds on the work of others and outlines how the method can be defined and operationalized within each context.
Collapse
Affiliation(s)
- Alexandra M Coates
- Department of Kinesiology, McMaster University, 1280 Main St West, Hamilton, ON, L8S 4K1, Canada
| | - Michael J Joyner
- Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN, USA
| | - Jonathan P Little
- School of Health and Exercise Sciences, University of British Columbia, Kelowna, BC, Canada
| | - Andrew M Jones
- Sport and Health Sciences, University of Exeter, Exeter, UK
| | - Martin J Gibala
- Department of Kinesiology, McMaster University, 1280 Main St West, Hamilton, ON, L8S 4K1, Canada.
| |
Collapse
|
68
|
Chorley A, Marwood S, Lamb KL. A dynamic model of the bi-exponential reconstitution and expenditure of W' in trained cyclists. Eur J Sport Sci 2023; 23:2368-2378. [PMID: 37470470 DOI: 10.1080/17461391.2023.2238679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
ABSTRACTThe aim of this study was to investigate the effects of different recovery power outputs on the reconstitution of W' and to develop a dynamic bi-exponential model of W' during depletion and reconstitution. Ten trained cyclists (mass 71.7 ± 8.4 kg; V̇O2max 60.0 ± 6.3 ml·kg-1·min-1) completed three incremental ramps (20 W·min-1) to the limit of tolerance on each of six occasions with recovery durations of 30 and 240 s. Recovery power outputs varied between 50 W (LOW); 60% of critical power (CP) (MOD) and 85% of CP (HVY). W' reconstitution was measured following each recovery and fitted to a bi-exponential model. Amplitude and time constant (τ) parameters were then determined via regression analysis accounting for relative intensity and duration to produce a dynamic model of W'. W' reconstitution slowed disproportionately as recovery power output increased (p < 0.001) and increased with recovery duration (p < 0.001). The amplitudes of each recovery component were strongly correlated to W' reconstitution after 240 s at HVY (r = 0.95), whilst τ parameters were found to be related to the fractional difference between recovery power and CP. The predictive capacity of the resultant model was assessed against experimental data with no differences found between predicted and experimental values of W' reconstitution (p > 0.05). The dynamic bi-exponential model of W' accounting for varying recovery intensities closely described W' kinetics in trained cyclists facilitating real-time decisions about pacing and tactics during competition. The model can be customised for individuals from known CP and W' and a single additional test session.HighlightsA dynamic bi-exponential model of W' accounting for both varying power output and duration.Individual customisation of the model can be achieved with a single specific test session.W' reconstitution slows disproportionally with increasing intensity after repeated bouts.
Collapse
Affiliation(s)
- Alan Chorley
- Department of Sport and Exercise Sciences, University of Chester, Chester, UK
| | - Simon Marwood
- School of Health Sciences, Liverpool Hope University, Liverpool, UK
| | - Kevin L Lamb
- Department of Sport and Exercise Sciences, University of Chester, Chester, UK
| |
Collapse
|
69
|
Nolte S, Rein R, Quittmann OJ. Data Processing Strategies to Determine Maximum Oxygen Uptake: A Systematic Scoping Review and Experimental Comparison with Guidelines for Reporting. Sports Med 2023; 53:2463-2475. [PMID: 37603201 PMCID: PMC10687136 DOI: 10.1007/s40279-023-01903-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/26/2023] [Indexed: 08/22/2023]
Abstract
BACKGROUND Gas exchange data from maximum oxygen uptake ([Formula: see text]) testing typically require post-processing. Different processing strategies may lead to varying [Formula: see text] values affecting their interpretation. However, the exact processing strategies used in the literature have yet to be systematically investigated. Previous research investigated differences across methods at the group level only. METHODS Out of a random sample, we investigated 242 recently published articles that measured [Formula: see text] during ramp tests. Reported data processing methods and their rationale were extracted. We compared the most common processing strategies on a data set of 72 standardized exercise tests in trained athletes. RESULTS Half of the included studies did not report their data processing strategy and almost all articles failed to provide a rationale for the particular strategy chosen. Most studies use binned time averages to determine [Formula: see text], with a minority using moving time or moving breath averages. The processing strategies found in the literature can lead to mean differences in [Formula: see text] of more than 5% (range 0-7%) with considerable variation at the individual level. CONCLUSIONS We advise researchers to change their processing strategy and use moving averages or digital filters instead of binned averages. Researchers should report their data processing strategy used to determine [Formula: see text]. We provide a reporting checklist of seven items that can function as a template for reporting.
Collapse
Affiliation(s)
- Simon Nolte
- Institute of Movement and Neurosciences, German Sport University Cologne, Cologne, Germany.
| | - Robert Rein
- Institute of Exercise Training and Sport Informatics, German Sport University Cologne, Cologne, Germany
| | - Oliver Jan Quittmann
- Institute of Movement and Neurosciences, German Sport University Cologne, Cologne, Germany
| |
Collapse
|
70
|
McDougall RM, Tripp TR, Frankish BP, Doyle-Baker PK, Lun V, Wiley JP, Aboodarda SJ, MacInnis MJ. The influence of skeletal muscle mitochondria and sex on critical torque and performance fatiguability in humans. J Physiol 2023; 601:5295-5316. [PMID: 37902588 DOI: 10.1113/jp284958] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 10/04/2023] [Indexed: 10/31/2023] Open
Abstract
Critical torque (CT) represents the highest oxidative steady state for intermittent knee extensor exercise, but the extent to which it is influenced by skeletal muscle mitochondria and sex is unclear. Vastus lateralis muscle biopsy samples were collected from 12 females and 12 males -matched for relative maximal oxygen uptake normalized to fat-free mass (FFM) (F: 57.3 (7.5) ml (kg FFM)-1 min-1 ; M: 56.8 (7.6) ml (kg FFM)-1 min-1 ; P = 0.856) - prior to CT determination and performance fatiguability trials. Males had a lower proportion of myosin heavy chain (MHC) I isoform (40.6 (18.4)%) compared to females (59.5 (18.9)%; P = 0.021), but MHC IIa and IIx isoform distributions and protein markers of mitochondrial content were not different between sexes (P > 0.05). When normalized to maximum voluntary contraction (MVC), the relative CT (F: 42.9 (8.3)%; M: 37.9 (9.0)%; P = 0.172) and curvature constant, W' (F: 26.6 (11.0) N m s (N m)-1 ; M: 26.4 (6.5) N m s (N m)-1 ; P = 0.962) were not significantly different between sexes. All protein biomarkers of skeletal muscle mitochondrial content, as well as the proportion of MHC I isoform, positively correlated with relative CT (0.48 < r < 0.70; P < 0.05), and the proportion of MHC IIx isoform correlated positively with relative W' (r = 0.57; P = 0.007). Indices of performance fatiguability were not different between males and females for MVC- and CT-controlled trials (P > 0.05). Greater mitochondrial protein abundance was associated with attenuated declines in potentiated twitch torque for exercise at 60% MVC (P < 0.05); however, the influence of mitochondrial protein abundance on performance fatiguability was reduced when exercise was prescribed relative to CT. Whether these findings translate to whole-body exercise requires additional research. KEY POINTS: The quadriceps critical torque represents the highest intensity of intermittent knee extensor exercise for which an oxidative steady state is attainable, but its relationship with skeletal muscle mitochondrial protein abundance is unknown. Matching males and females for maximal oxygen uptake relative to fat-free mass facilitates investigations of sex differences in exercise physiology, but studies that have compared critical torque and performance fatiguability during intermittent knee extensor exercise have not ensured equal aerobic fitness between sexes. Skeletal muscle mitochondrial protein abundance was correlated with critical torque and fatigue resistance for exercise prescribed relative to maximum voluntary contraction but not for exercise performed relative to the critical torque. Differences between sexes in critical torque, skeletal muscle mitochondrial protein abundance and performance fatiguability were not statistically significant. Our results suggest that skeletal muscle mitochondrial protein abundance may contribute to fatigue resistance by influencing the critical intensity of exercise.
Collapse
Affiliation(s)
| | - Thomas R Tripp
- Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
| | | | | | - Victor Lun
- Faculty of Kinesiology, University of Calgary Sport Medicine Centre, University of Calgary, Calgary, Alberta, Canada
| | - J Preston Wiley
- Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
- Faculty of Kinesiology, University of Calgary Sport Medicine Centre, University of Calgary, Calgary, Alberta, Canada
| | - S Jalal Aboodarda
- Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
| | - Martin J MacInnis
- Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
71
|
Miller P, Perez N, Farrell JW. Acute Oxygen Consumption Response to Fast Start High-Intensity Intermittent Exercise. Sports (Basel) 2023; 11:238. [PMID: 38133105 PMCID: PMC10747366 DOI: 10.3390/sports11120238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 11/10/2023] [Accepted: 11/28/2023] [Indexed: 12/23/2023] Open
Abstract
The current investigation compared the acute oxygen consumption (VO2) response of two high-intensity interval exercises (HIIE), fast start (FSHIIE), and steady power (SPHIIE), which matched w prime (W') depletion. Eight cyclists completed an incremental max test and a three-minute all-out test (3MT) to determine maximal oxygen consumption (VO2max), critical power (CP), and W'. HIIE sessions consisted of 3 X 4 min intervals interspersed by 3 min of active recovery, with W' depleted by 60% (W'target) within each working interval. SPHIIE depleted the W'target consistently throughout the 3 min intervals, while FSHIIE depleted the W'target by 50% within the first minute, with the remaining 50% depleted evenly across the remainder of the interval. The paired samples t-test revealed no differences in the percentage of training time spent above 90% of VO2max (PT ≥ 90% VO2max) between SPHIIE and FSHIIE with an average of 25.20% and 26.07%, respectively. Pairwise comparisons indicated a difference between minute 1 peak VO2, minute 2, and minute 3, while no differences were present between minutes 2 and 3. The results suggest that when HIIE formats are matched based on W' expenditure, there are no differences in PT ≥ 90% VO2max or peak VO2 during each interval.
Collapse
Affiliation(s)
| | | | - John W. Farrell
- Clinical Biomechanics and Exercise Physiology Laboratory, Texas State University, San Marcos, TX 78666, USA; (P.M.)
| |
Collapse
|
72
|
Hunter SK, S Angadi S, Bhargava A, Harper J, Hirschberg AL, D Levine B, L Moreau K, J Nokoff N, Stachenfeld NS, Bermon S. The Biological Basis of Sex Differences in Athletic Performance: Consensus Statement for the American College of Sports Medicine. Med Sci Sports Exerc 2023; 55:2328-2360. [PMID: 37772882 DOI: 10.1249/mss.0000000000003300] [Citation(s) in RCA: 49] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/30/2023]
Abstract
ABSTRACT Biological sex is a primary determinant of athletic performance because of fundamental sex differences in anatomy and physiology dictated by sex chromosomes and sex hormones. Adult men are typically stronger, more powerful, and faster than women of similar age and training status. Thus, for athletic events and sports relying on endurance, muscle strength, speed, and power, males typically outperform females by 10%-30% depending on the requirements of the event. These sex differences in performance emerge with the onset of puberty and coincide with the increase in endogenous sex steroid hormones, in particular testosterone in males, which increases 30-fold by adulthood, but remains low in females. The primary goal of this consensus statement is to provide the latest scientific knowledge and mechanisms for the sex differences in athletic performance. This review highlights the differences in anatomy and physiology between males and females that are primary determinants of the sex differences in athletic performance and in response to exercise training, and the role of sex steroid hormones (particularly testosterone and estradiol). We also identify historical and nonphysiological factors that influence the sex differences in performance. Finally, we identify gaps in the knowledge of sex differences in athletic performance and the underlying mechanisms, providing substantial opportunities for high-impact studies. A major step toward closing the knowledge gap is to include more and equitable numbers of women to that of men in mechanistic studies that determine any of the sex differences in response to an acute bout of exercise, exercise training, and athletic performance.
Collapse
Affiliation(s)
- Sandra K Hunter
- Exercise Science Program, Department of Physical Therapy, and Athletic and Human Performance Center, Marquette University, Milwaukee, WI
| | | | - Aditi Bhargava
- Department of Obstetrics and Gynecology, Center for Reproductive Sciences, University of California, San Francisco, CA
| | - Joanna Harper
- Loughborough University, Loughborough, UNITED KINGDOM
| | - Angelica Lindén Hirschberg
- Department of Women's and Children's Health, Karolinska Institutet, and Department of Gynecology and Reproductive Medicine, Karolinska University Hospital, Stockholm, SWEDEN
| | - Benjamin D Levine
- Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital Dallas, and the Department of Internal Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, Dallas, TX
| | - Kerrie L Moreau
- Department of Medicine, Division of Geriatric Medicine, University of Colorado Anschutz Medical Campus, and Eastern Colorado Health Care System, Geriatric Research Education and Clinical Center, Aurora, CO
| | - Natalie J Nokoff
- Department of Pediatrics, Section of Endocrinology, University of Colorado Anschutz Medical Campus, Aurora, CO
| | - Nina S Stachenfeld
- The John B. Pierce Laboratory and Department of Obstetrics, Gynecology and Reproductive Sciences, Yale School of Medicine, New Haven, CT
| | - Stéphane Bermon
- Health and Science Department, World Athletics, Monaco and the LAMHESS, University Côte d'Azur, Nice, FRANCE
| |
Collapse
|
73
|
Veith DD, Linde MB, Wiggins CC, Zhao KD, Garlanger KL. Intervention Design of High-Intensity Interval Training in Individuals With Spinal Cord Injury: Narrative Review and Future Perspectives. Top Spinal Cord Inj Rehabil 2023; 29:1-15. [PMID: 38076494 PMCID: PMC10704212 DOI: 10.46292/sci22-00045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Background Individuals with spinal cord injury (SCI) have lower levels of physical activity compared to the nondisabled population. Exercise guidelines recommend moderate or vigorous exercise to improve cardiovascular health and reduce cardiometabolic risk factors in persons with SCI. High-intensity interval training (HIIT) is a popular exercise choice and encompasses brief periods of vigorous exercise paired with intermittent periods of recovery. Objectives This review describes the available literature on HIIT for individuals with SCI, including differences in protocol design and suggested areas of further investigation. Methods Our institution's library system performed the comprehensive search. The primary keywords and phrases used to search included spinal cord injury, high-intensity interval training, tetraplegia, paraplegia, and several other related terms. Results Initially 62 records were screened, and 36 were deemed outside the scope of this review. Twenty-six studies published between 2001 and 2021 fulfilled the eligibility criteria and were divided among two researchers for review and analysis. All records required persons with SCI and a standardized HIIT intervention. Study design varied widely with respect to mode of exercise, prescribed intensity, duration of performance intervals, and session duration. This variability necessitates further investigation into the specifics of a HIIT prescription and the associated outcomes for persons with SCI. Conclusion Standardization of HIIT protocols may lead to more robust conclusions regarding its effects on cardiorespiratory fitness as well as mitigation of cardiometabolic risk factors. Meta-analyses will eventually be needed on proper dosing and session parameters to improve cardiorespiratory fitness and cardiometabolic risk factors.
Collapse
Affiliation(s)
- Daniel D. Veith
- Department of Physical Medicine & Rehabilitation, Mayo Clinic, Rochester, Minnesota
| | - Margaux B. Linde
- Department of Physical Medicine & Rehabilitation, Mayo Clinic, Rochester, Minnesota
| | - Chad C. Wiggins
- Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, Minnesota
| | - Kristin D. Zhao
- Department of Physical Medicine & Rehabilitation, Mayo Clinic, Rochester, Minnesota
| | - Kristin L. Garlanger
- Department of Physical Medicine & Rehabilitation, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
74
|
Bourgois G, Mucci P, Boone J, Colosio AL, Bourgois JG, Pogliaghi S, Caen K. Critical power, W' and W' reconstitution in women and men. Eur J Appl Physiol 2023; 123:2791-2801. [PMID: 37369796 DOI: 10.1007/s00421-023-05268-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 06/20/2023] [Indexed: 06/29/2023]
Abstract
PURPOSE The aim of this study was to compare critical power (CP) and work capacity W', and W' reconstitution (W'REC) following repeated maximal exercise between women and men. METHODS Twelve women ([Formula: see text]O2PEAK: 2.53 ± 0.37 L·min-1) and 12 men ([Formula: see text]O2PEAK: 4.26 ± 0.30 L·min-1) performed a minimum of 3 constant workload tests, to determine CP and W', and 1 maximal exercise repetition test with three work bouts (WB) to failure, to quantify W'REC during 2 recovery periods, i.e., W'REC1 and W'REC2. An independent samples t test was used to compare CP and W' values between women and men, and a repeated-measures ANOVA was used to compare W'REC as fraction of W' expended during the first WB, absolute W'REC, and normalized to lean body mass (LBM). RESULTS CP normalized to LBM was not different between women and men, respectively, 3.7 ± 0.5 vs. 4.1 ± 0.4 W·kgLBM-1, while W' normalized to LBM was lower in women 256 ± 29 vs. 305 ± 45 J·kgLBM-1. Fractional W'REC1 was higher in women than in men, respectively, 74.0 ± 12.0% vs. 56.8 ± 9.5%. Women reconstituted less W' than men in absolute terms (8.7 ± 1.2 vs. 10.9 ± 2.0 kJ) during W'REC1, while normalized to LBM no difference was observed between women and men (174 ± 23 vs. 167 ± 31 J·kgLBM-1). W'REC2 was lower than W'REC1 both in women and men. CONCLUSION Sex differences in W'REC (absolute women < men; fractional women > men) are eliminated when LBM is accounted for. Prediction models of W'REC might benefit from including LBM as a biological variable in the equation. This study confirms the occurrence of a slowing of W'REC during repeated maximal exercise.
Collapse
Affiliation(s)
- Gil Bourgois
- Department of Movement and Sports Sciences, Ghent University, Watersportlaan 2, 9000, Ghent, Belgium
- Univ. Lille, Univ. Artois, Univ. Littoral Côte d'Opale, ULR 7369-URePSSS-Unité de Recherche Pluridisciplinaire Sport Santé Société, 59000, Lille, France
| | - Patrick Mucci
- Univ. Lille, Univ. Artois, Univ. Littoral Côte d'Opale, ULR 7369-URePSSS-Unité de Recherche Pluridisciplinaire Sport Santé Société, 59000, Lille, France
| | - Jan Boone
- Department of Movement and Sports Sciences, Ghent University, Watersportlaan 2, 9000, Ghent, Belgium.
- Center of Sports Medicine, Ghent University Hospital, Ghent, Belgium.
| | - Alessandro L Colosio
- Department of Movement and Sports Sciences, Ghent University, Watersportlaan 2, 9000, Ghent, Belgium
| | - Jan G Bourgois
- Department of Movement and Sports Sciences, Ghent University, Watersportlaan 2, 9000, Ghent, Belgium
- Center of Sports Medicine, Ghent University Hospital, Ghent, Belgium
| | - Silvia Pogliaghi
- Department of Movement and Sports Sciences, Ghent University, Watersportlaan 2, 9000, Ghent, Belgium
- Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, Verona, Italy
| | - Kevin Caen
- Department of Movement and Sports Sciences, Ghent University, Watersportlaan 2, 9000, Ghent, Belgium
- Center of Sports Medicine, Ghent University Hospital, Ghent, Belgium
| |
Collapse
|
75
|
Hunter B, Ledger A, Muniz-Pumares D. Remote Determination of Critical Speed and Critical Power in Recreational Runners. Int J Sports Physiol Perform 2023; 18:1449-1456. [PMID: 37888148 DOI: 10.1123/ijspp.2023-0276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 08/10/2023] [Accepted: 09/05/2023] [Indexed: 10/28/2023]
Abstract
PURPOSE This study aimed to compare estimations of critical speed (CS) and work completed above CS (D'), and their analogies for running power (critical power [CP] and W'), derived from raw data obtained from habitual training (HAB) and intentional maximal efforts in the form of time trials (TTs) and 3-minute all-out tests (3MTs) in recreational runners. The test-retest reliability of the 3MT was further analyzed. METHODS Twenty-three recreational runners (4 female) used a foot pod to record speed, altitude, and power output for 8 consecutive weeks. CS and D', and CP and W', were calculated from the best 3-, 7-, and 12-minute segments recorded in the first 6 weeks of their HAB and in random order in weeks 7 and 8 from 3 TTs (3, 7, and 12 min) and three 3MTs (to assess test-retest reliability). RESULTS There was no difference between estimations of CS or CP derived from HAB, TT, and 3MT (3.44 [0.63], 3.42 [0.53], and 3.76 [0.57] m · s-1 and 281 [41], 290 [45], and 305 [54] W, respectively), and strong agreement between HAB and TT for CS (r = .669) and CP (r = .916). Limited agreement existed between estimates of D'/W'. Moderate reliability of D'/W' was demonstrated between the first and second 3MTs, whereas excellent reliability was demonstrated for CS/CP. CONCLUSION These data suggest that estimations of CS/CP can be derived remotely, from either HAB, TT, or 3MT, although the lower agreement between D'/W' warrants caution when using these measures interchangeably.
Collapse
Affiliation(s)
- Ben Hunter
- School of Life and Medical Sciences, University of Hertfordshire, Hatfield, United Kingdom
- School of Human Science, London Metropolitan University, London, United Kingdom
| | - Adam Ledger
- School of Life and Medical Sciences, University of Hertfordshire, Hatfield, United Kingdom
| | - Daniel Muniz-Pumares
- School of Life and Medical Sciences, University of Hertfordshire, Hatfield, United Kingdom
| |
Collapse
|
76
|
Lei T, Wang I, Chen Y, Liu X, Fujii N, Koga S, Perry B, Mundel T, Wang F, Cao Y, Dobashi K, Kondo N, Li H, Goulding RP. Critical power is a key threshold determining the magnitude of post-exercise hypotension in non-hypertensive young males. Exp Physiol 2023; 108:1409-1421. [PMID: 37712355 PMCID: PMC10988428 DOI: 10.1113/ep091429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 08/24/2023] [Indexed: 09/16/2023]
Abstract
The effect of different exercise intensities on the magnitude of post-exercise hypotension has not been rigorously clarified with respect to the metabolic thresholds that partition discrete exercise intensity domains (i.e., critical power and the gas exchange threshold (GET)). We hypothesized that the magnitude of post-exercise hypotension would be greater following isocaloric exercise performed above versus below critical power. Twelve non-hypertensive men completed a ramp incremental exercise test to determine maximal oxygen uptake and the GET, followed by five exhaustive constant load trials to determine critical power and W' (work available above critical power). Subsequently, criterion trials were performed at four discrete intensities matched for total work performed (i.e., isocaloric) to determine the impact of exercise intensity on post-exercise hypotension: 10% above critical power (10% > CP), 10% below critical power (10% < CP), 10% above GET (10% > GET) and 10% below GET (10% < GET). The post-exercise decrease (i.e., the minimum post-exercise values) in mean arterial (10% > CP: -12.7 ± 8.3 vs. 10% < CP: v3.5 ± 2.9 mmHg), diastolic (10% > CP: -9.6 ± 9.8 vs. 10% < CP: -1.4 ± 5.0 mmHg) and systolic (10% > CP: -23.8 ± 7.0 vs. 10% < CP: -9.9 ± 4.3 mmHg) blood pressures were greater following exercise performed 10% > CP compared to all other trials (all P < 0.01). No effects of exercise intensity on the magnitude of post-exercise hypotension were observed during exercise performed below critical power (all P > 0.05). Critical power represents a threshold above which the magnitude of post-exercise hypotension is greatly augmented. NEW FINDINGS: What is the central questions of this study? What is the influence of exercise intensity on the magnitude of post-exercise hypotension with respect to metabolic thresholds? What is the main finding and its importance? The magnitude of post-exercise hypotension is greatly increased following exercise performed above critical power. However, below critical power, there was no clear effect of exercise intensity on the magnitude of post-exercise hypotension.
Collapse
Affiliation(s)
- Tze‐Huan Lei
- College of Physical EducationHubei Normal UniversityHuangshiChina
| | - I‐Lin Wang
- College of Physical EducationHubei Normal UniversityHuangshiChina
| | - Yi‐Ming Chen
- Department of Food ScienceFu Jen Catholic UniversityNew Taipei CityTaiwan
| | - Xin‐Hao Liu
- College of Physical EducationHubei Normal UniversityHuangshiChina
| | - Naoto Fujii
- Faculty of Health and Sport SciencesUniversity of TsukubaTsukubaJapan
| | - Shunsaku Koga
- Applied Physiology LaboratoryKobe Design UniversityKobeJapan
| | - Blake Perry
- School of Health SciencesMassey UniversityWellingtonNew Zealand
| | - Toby Mundel
- Department of KinesiologyBrock UniversitySt CatharinesCanada
| | - Faming Wang
- Division Animal and Human Health Engineering, Department of Biosystems (BIOSYST)KU LeuvenLeuvenBelgium
| | - Yinhang Cao
- School of Athletic PerformanceShanghai Sport UniversityShanghaiChina
| | - Kohei Dobashi
- Faculty of EducationHokkaido University of EducationAsahikawaJapan
| | - Narihiko Kondo
- Laboratory for Applied Human Physiology, Graduate School of Human Development and EnvironmentKobe UniversityKobeJapan
| | - Hao‐Yu Li
- College of Physical EducationHubei Normal UniversityHuangshiChina
| | - Richie P. Goulding
- Laboratory for Myology, Department of Human Movement Sciences, Faculty of Behavioral and Human Movement Sciences, Vrije Universiteit AmsterdamAmsterdam Movement SciencesAmsterdamthe Netherlands
| |
Collapse
|
77
|
Gifford JR, Larsen J. Our understanding of the role of exercise intensity can only be precise as our classification of exercise intensity. Exp Physiol 2023; 108:1374-1375. [PMID: 37750810 PMCID: PMC10988519 DOI: 10.1113/ep091512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 09/15/2023] [Indexed: 09/27/2023]
|
78
|
Ventura TP, Borszcz FK, Antunes D, Caputo F, Turnes T. Prediction of Exercise Tolerance in the Severe and Extreme Intensity Domains by a Critical Power Model. J Hum Kinet 2023; 89:113-122. [PMID: 38053952 PMCID: PMC10694707 DOI: 10.5114/jhk/170101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 04/05/2023] [Indexed: 12/07/2023] Open
Abstract
This study aimed to assess the predictive capability of different critical power (CP) models on cycling exercise tolerance in the severe- and extreme-intensity domains. Nineteen cyclists (age: 23.0 ± 2.7 y) performed several time-to-exhaustion tests (Tlim) to determine CP, finite work above CP (W'), and the highest constant work rate at which maximal oxygen consumption was attained (IHIGH). Hyperbolic power-time, linear power-inverse of time, and work-time models with three predictive trials were used to determine CP and W'. Modeling with two predictive trials of the CP work-time model was also used to determine CP and W'. Actual exercise tolerance of IHIGH and intensity 5% above IHIGH (IHIGH+5%) were compared to those predicted by all CP models. Actual IHIGH (155 ± 30 s) and IHIGH+5% (120 ± 26 s) performances were not different from those predicted by all models with three predictive trials. Modeling with two predictive trials overestimated Tlim at IHIGH+5% (129 ± 33 s; p = 0.04). Bland-Altman plots of IHIGH+5% presented significant heteroscedasticity by all CP predictions, but not for IHIGH. Exercise tolerance in the severe and extreme domains can be predicted by CP derived from three predictive trials. However, this ability is impaired within the extreme domain.
Collapse
Affiliation(s)
- Thiago Pereira Ventura
- Physical Effort Laboratory, Sports Center, Federal University of Santa Catarina, Florianopolis, Brazil
| | - Fernando Klitzke Borszcz
- Physical Effort Laboratory, Sports Center, Federal University of Santa Catarina, Florianopolis, Brazil
| | - Diego Antunes
- Physical Effort Laboratory, Sports Center, Federal University of Santa Catarina, Florianopolis, Brazil
| | - Fabrizio Caputo
- Human Performance Research Group, Center for Health Sciences and Sport, Santa Catarina State University, Florianopolis, Brazil
| | - Tiago Turnes
- Physical Effort Laboratory, Sports Center, Federal University of Santa Catarina, Florianopolis, Brazil
| |
Collapse
|
79
|
Ruiz-Alias SA, Ñancupil-Andrade AA, Pérez-Castilla A, García-Pinillos F. Can we predict long-duration running power output? A matter of selecting the appropriate predicting trials and empirical model. Eur J Appl Physiol 2023; 123:2283-2294. [PMID: 37272943 DOI: 10.1007/s00421-023-05243-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Accepted: 05/26/2023] [Indexed: 06/06/2023]
Abstract
When facing a long-distance race, athletes and practitioners could develop an efficient pacing strategy and training paces if an accurate performance estimate of the target distance is achieved. Therefore, this study aims to determine the validity of different empirical models (i.e. critical power [CP], Power law and Peronnet) to predict long-duration power output (i.e. 60 min) when using two or three time trial configurations. In a 5-week training period, fifteen highly trained athletes performed nine-time trials (i.e. 1, 2, 3, 4, 5, 10, 20, 30, and 60 min) in a randomized order. Their power-duration curves were defined through the work-time (CPwork), power-1/time (CP1/time), two-parameter hyperbolic (CP2hyp), three-parameter hyperbolic (CP3hyp) CP models using different two- and three-time trial configurations. The undisclosed proprietary CP models of the Stryd (CPstryd) and Golden Cheetah training software (CPcheetah) were also computed as well as the non-asymptotic Power law and Peronnet models. These were extrapolated to the 60-min power output and compared to the actual performance. The shortest valid configuration (95% confidence interval < 12 W) for CPwork and CP1/time was 3-30 min (Bias: 8.3 [4.9 to 11.7] W), for CPstryd was 10-30 min (Bias: 4.2 [- 1.0 to 9.4] W), for CP2hyp, CP3hyp and CPcheetah was 3-5-30 min (Bias < 5.7 W), for Power law was 1-3-10 min (- 1.0 [- 11.9 to 9.9] W), and for Peronnet was 4-20 min (- 3.0 [- 10.2 to 4.3] W). All the empirical models provided valid estimates when the two or three predicting trial configurations selected attended each model fitting needs.
Collapse
Affiliation(s)
- Santiago A Ruiz-Alias
- Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, Carretera de Alfacar 21, 18011, Granada, Spain.
- Sport and Health University Research Center (iMUDS), University of Granada, C/. Menéndez Pelayo 32, 18016, Granada, Spain.
| | - Alberto A Ñancupil-Andrade
- Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, Carretera de Alfacar 21, 18011, Granada, Spain
- Sport and Health University Research Center (iMUDS), University of Granada, C/. Menéndez Pelayo 32, 18016, Granada, Spain
- Department of Health, Los Lagos University, Puerto Montt, Chile
| | - Alejandro Pérez-Castilla
- Department of Education, Faculty of Education Sciences, University of Almería, Almería, Spain
- SPORT Research Group (CTS-1024), CERNEP Research Center, University of Almería, Almería, Spain
| | - Felipe García-Pinillos
- Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, Carretera de Alfacar 21, 18011, Granada, Spain
- Sport and Health University Research Center (iMUDS), University of Granada, C/. Menéndez Pelayo 32, 18016, Granada, Spain
- Department of Physical Education, Sports and Recreation, Universidad de La Frontera, Temuco, Chile
| |
Collapse
|
80
|
Wallis TJM, Minnion M, Freeman A, Bates A, Otto JM, Wootton SA, Fletcher SV, Grocott MPW, Feelisch M, Jones MG, Jack S. Individualised Exercise Training Enhances Antioxidant Buffering Capacity in Idiopathic Pulmonary Fibrosis. Antioxidants (Basel) 2023; 12:1645. [PMID: 37627640 PMCID: PMC10451244 DOI: 10.3390/antiox12081645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 08/13/2023] [Accepted: 08/16/2023] [Indexed: 08/27/2023] Open
Abstract
Exercise training is recommended for patients with idiopathic pulmonary fibrosis (IPF); however, the mechanism(s) underlying its physiological benefits remain unclear. We investigated the effects of an individualised aerobic interval training programme on exercise capacity and redox status in IPF patients. IPF patients were recruited prospectively to an 8-week, twice-weekly cardiopulmonary exercise test (CPET)-derived structured responsive exercise training programme (SRETP). Systemic redox status was assessed pre- and post-CPET at baseline and following SRETP completion. An age- and sex-matched non-IPF control cohort was recruited for baseline comparison only. At baseline, IPF patients (n = 15) had evidence of increased oxidative stress compared with the controls as judged by; the plasma reduced/oxidised glutathione ratio (median, control 1856 vs. IPF 736 p = 0.046). Eleven IPF patients completed the SRETP (median adherence 88%). Following SRETP completion, there was a significant improvement in exercise capacity assessed via the constant work-rate endurance time (+82%, p = 0.003). This was accompanied by an improvement in post-exercise redox status (in favour of antioxidants) assessed via serum total free thiols (median increase, +0.26 μmol/g protein p = 0.005) and total glutathione concentration (+0.73 μM p = 0.03), as well as a decrease in post-exercise lipid peroxidation products (-1.20 μM p = 0.02). Following SRETP completion, post-exercise circulating nitrite concentrations were significantly lower compared with baseline (-0.39 μM p = 0.04), suggestive of exercise-induced nitrite utilisation. The SRETP increased both endurance time and systemic antioxidant capacity in IPF patients. The observed reduction in nitrite concentrations provides a mechanistic rationale to investigate nitrite/nitrate supplementation in IPF patients.
Collapse
Affiliation(s)
- Tim J. M. Wallis
- NIHR Southampton Biomedical Research Centre, Respiratory and Critical Care, University Hospital Southampton, Southampton SO16 6YD, UK; (M.M.); (A.F.); (A.B.); (J.M.O.); (S.V.F.); (M.P.W.G.); (M.F.); (M.G.J.); (S.J.)
- Academic School of Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK;
| | - Magdalena Minnion
- NIHR Southampton Biomedical Research Centre, Respiratory and Critical Care, University Hospital Southampton, Southampton SO16 6YD, UK; (M.M.); (A.F.); (A.B.); (J.M.O.); (S.V.F.); (M.P.W.G.); (M.F.); (M.G.J.); (S.J.)
- Academic School of Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK;
| | - Anna Freeman
- NIHR Southampton Biomedical Research Centre, Respiratory and Critical Care, University Hospital Southampton, Southampton SO16 6YD, UK; (M.M.); (A.F.); (A.B.); (J.M.O.); (S.V.F.); (M.P.W.G.); (M.F.); (M.G.J.); (S.J.)
- Academic School of Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK;
| | - Andrew Bates
- NIHR Southampton Biomedical Research Centre, Respiratory and Critical Care, University Hospital Southampton, Southampton SO16 6YD, UK; (M.M.); (A.F.); (A.B.); (J.M.O.); (S.V.F.); (M.P.W.G.); (M.F.); (M.G.J.); (S.J.)
- Academic School of Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK;
- Department of Critical Care and Anaesthesia, University Hospital Southampton, Southampton SO16 6YD, UK
| | - James M. Otto
- NIHR Southampton Biomedical Research Centre, Respiratory and Critical Care, University Hospital Southampton, Southampton SO16 6YD, UK; (M.M.); (A.F.); (A.B.); (J.M.O.); (S.V.F.); (M.P.W.G.); (M.F.); (M.G.J.); (S.J.)
- Academic School of Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK;
- Department of Critical Care and Anaesthesia, University Hospital Southampton, Southampton SO16 6YD, UK
| | - Stephen A. Wootton
- Academic School of Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK;
- NIHR Southampton Biomedical Research Centre, Nutrition and Metabolism, University Hospital Southampton, Southampton SO16 6YD, UK
| | - Sophie V. Fletcher
- NIHR Southampton Biomedical Research Centre, Respiratory and Critical Care, University Hospital Southampton, Southampton SO16 6YD, UK; (M.M.); (A.F.); (A.B.); (J.M.O.); (S.V.F.); (M.P.W.G.); (M.F.); (M.G.J.); (S.J.)
- Academic School of Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK;
| | - Michael P. W. Grocott
- NIHR Southampton Biomedical Research Centre, Respiratory and Critical Care, University Hospital Southampton, Southampton SO16 6YD, UK; (M.M.); (A.F.); (A.B.); (J.M.O.); (S.V.F.); (M.P.W.G.); (M.F.); (M.G.J.); (S.J.)
- Academic School of Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK;
- Department of Critical Care and Anaesthesia, University Hospital Southampton, Southampton SO16 6YD, UK
| | - Martin Feelisch
- NIHR Southampton Biomedical Research Centre, Respiratory and Critical Care, University Hospital Southampton, Southampton SO16 6YD, UK; (M.M.); (A.F.); (A.B.); (J.M.O.); (S.V.F.); (M.P.W.G.); (M.F.); (M.G.J.); (S.J.)
- Academic School of Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK;
| | - Mark G. Jones
- NIHR Southampton Biomedical Research Centre, Respiratory and Critical Care, University Hospital Southampton, Southampton SO16 6YD, UK; (M.M.); (A.F.); (A.B.); (J.M.O.); (S.V.F.); (M.P.W.G.); (M.F.); (M.G.J.); (S.J.)
- Academic School of Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK;
- Institute for Life Sciences, University of Southampton, Southampton SO17 1BJ, UK
| | - Sandy Jack
- NIHR Southampton Biomedical Research Centre, Respiratory and Critical Care, University Hospital Southampton, Southampton SO16 6YD, UK; (M.M.); (A.F.); (A.B.); (J.M.O.); (S.V.F.); (M.P.W.G.); (M.F.); (M.G.J.); (S.J.)
- Academic School of Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK;
- Department of Critical Care and Anaesthesia, University Hospital Southampton, Southampton SO16 6YD, UK
| |
Collapse
|
81
|
Caen K, Bourgois JG, Stuer L, Mermans V, Boone J. Can We Accurately Predict Critical Power and W' from a Single Ramp Incremental Exercise Test? Med Sci Sports Exerc 2023; 55:1401-1408. [PMID: 36924332 DOI: 10.1249/mss.0000000000003171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
Abstract
PURPOSE The purpose of this study was to examine the suitability of a single ramp incremental test to predict critical power (CP) and W' . We hypothesized that CP would correspond to the corrected power output (PO) at the respiratory compensation point (RCP) and W' would be calculable from the work done above RCP. METHODS One hundred fifty-three healthy young people (26 ± 4 yr, 51.4 ± 7.6 mL·min -1 ·kg -1 ) performed a maximal ramp test (20, 25, or 30 W·min -1 ), followed by three to five constant load trials to determine CP and W' . CP and W' were estimated using a "best individual fit" approach, selecting the mathematical model with the smallest total error. The RCP was identified by means of gas exchange analysis and then translated into its appropriate PO by applying a correction strategy in order to account for the gap in the V̇O 2 /PO relationship between ramp and constant load exercise. We evaluated the agreement between CP and the PO at RCP, and between W' and the total work done above CP ( W'RAMP > CP ) and above RCP ( W'RAMP > RCP ) during the ramp test. RESULTS The CP was significantly higher than the PO at RCP (Δ = 8 ± 16 W, P < 0.001). W'RAMP > CP was significantly lower than W' (Δ = 1.9 ± 3.3 kJ, P < 0.001), whereas W'RAMP > RCP and W' did not differ from each other (Δ = -0.6 ± 5.8 kJ, P = 0.21). CONCLUSIONS Despite the fact that CP and RCP occurred in close proximity, the estimation of W' from ramp exercise may be problematic given the likelihood of underestimation and considering the large variability. Therefore, we do not recommend the interchangeable use of CP and W' values derived from constant load versus ramp exercise, in particular, when the goal is to obtain accurate estimates or to predict performance capacity.
Collapse
Affiliation(s)
| | | | - Lena Stuer
- Department of Movement and Sports Sciences, Ghent University, Ghent, BELGIUM
| | | | | |
Collapse
|
82
|
Billaut F, Demers MR, Hibbert A. Performance Kinetics During Repeated Sprints is Influenced by Knowledge of Task Endpoint and Associated Peripheral Fatigue. INTERNATIONAL JOURNAL OF EXERCISE SCIENCE 2023; 16:987-998. [PMID: 37649870 PMCID: PMC10464754 DOI: 10.70252/rlsm7428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 03/15/2025]
Abstract
The regulation of exercise intensity allows an athlete to perform an exercise in the fastest possible time while avoiding debilitating neuromuscular fatigue development. This phenomenon is less studied during intermittent activities. To investigate anticipatory and real-time regulation of motor output and neuromuscular fatigue during repeated-sprint exercise, twelve males randomly performed one (S1), two (S2), four (S4) and six (S6) sets of five 5-s cycling sprints. Mechanical work and electromyographic activity were assessed during sprints. Potentiated quadriceps twitch force (ΔQtw,pot) and central activation ratio (QCAR) were quantified from response to supra-maximal magnetic femoral nerve stimulation pre-vs post-exercise. Compared with S1, mechanical work developed in the first sprint and in the entire first set was reduced in S6 (-7.8% and -5.1%, respectively, P < 0.05). Work developed in the last set was similar in S4 and S6 (P = 0.82). Similar results were observed for EMG activity. The QCAR was also more reduced in S4 (-5.8%, P < 0.05) and S6 (-8.3%, P < 0.05) than in S1. However, ΔQtw,pot was not significantly different across all trials (-33.1% to -41.9%, P = 0.46). Perceived exhaustion increased across sprints to reach a maximal and similar level in S2, S4 and S6 (all 19.2, P < 0.01 vs S1). These results suggest that the regulation of performance, exerted at the beginning and continuously during repeated sprints, is based on the task endpoint, presumably to avoid excessive peripheral muscle and associated conscious overwhelming sensations.
Collapse
Affiliation(s)
- François Billaut
- Département de kinésiologie, Université Laval, Québec, QC, CANADA
| | | | - Andrew Hibbert
- Institute for Health & Sport, Victoria University, Melbourne, VIC, AUSTRALIA
| |
Collapse
|
83
|
Ducrocq GP, Al Assad SH, Kouzkouz N, Hureau TJ. The Role of Contraction Mode in Determining Exercise Tolerance, Torque-Duration Relationship, and Neuromuscular Fatigue. Med Sci Sports Exerc 2023; 55:1218-1231. [PMID: 36878018 DOI: 10.1249/mss.0000000000003145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2023]
Abstract
PURPOSE Critical torque (CT) and work done above it ( W ') are key predictors of exercise performance associated with neuromuscular fatigue. The aim of the present study was to understand the role of the metabolic cost of exercise in determining exercise tolerance, CT and W ', and the mechanisms of neuromuscular fatigue. METHODS Twelve subjects performed four knee extension time trials (6, 8, 10, and 12 min) using eccentric, isometric, or concentric contractions (3-s on/2-s off at 90°·s -1 or 30°·s -1 ) to modulate the metabolic cost of exercise. Exercise performance was quantified by total impulse and mean torque. Critical torque and W ' were determined using the linear relationship between total impulse and contraction time. Cardiometabolic, neuromuscular, and ventilatory responses were quantified. Neuromuscular function was evaluated by maximal voluntary contraction, resting potentiated single/doublet electrical stimulations, and superimposed single electrical stimulation to quantify neuromuscular, peripheral, and central fatigue, respectively. RESULTS Compared with isometric exercise, total impulse (+36% ± 21%; P < 0.001), CT (+27% ± 30%; P < 0.001), and W ' (+67% ± 99%; P < 0.001) were increased during eccentric exercise, whereas total impulse (-25% ± 7%; P < 0.001), critical torque (-26% ± 15%; P < 0.001), and W ' (-18% ± 19%; P < 0.001) were reduced in concentric exercise. Conversely, the metabolic response and the degree of peripheral fatigue were reduced during eccentric exercise, whereas they were increased during concentric exercise. Critical torque was negatively associated with oxygen consumption gain ( R2 = 0.636; P < 0.001), and W ' was negatively associated with rates of neuromuscular and peripheral fatigue indices ( R2 = 0.252-0.880; P < 0.001). CONCLUSIONS The contraction mode influenced both CT and W ', and consequently exercise tolerance, indicating that the metabolic cost of contraction played a key role.
Collapse
Affiliation(s)
- Guillaume P Ducrocq
- Mitochondria, Oxidative Stress and Muscular Protection Laboratory (UR 3072), Faculty of Medicine, University of Strasbourg, Strasbourg, FRANCE; European Centre for Education, Research and Innovation in Exercise Physiology (CEERIPE), Faculty of Sport Sciences, University of Strasbourg, Strasbourg, FRANCE
| | | | | | | |
Collapse
|
84
|
McCLEAN ZJ, MacDOUGALL KB, Fletcher JR, Aboodarda SJ, Macintosh BR. Test-Retest Reliability of a 4-Minute All-Out Critical Force Test in Rock Climbers. INTERNATIONAL JOURNAL OF EXERCISE SCIENCE 2023; 16:912-923. [PMID: 37637240 PMCID: PMC10449326 DOI: 10.70252/dbic1991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/15/2025]
Abstract
The purpose of this study was to assess the test-retest reliability of a 4-minute all-out critical force test in well-trained rock climbers. Thirteen rock climbers (n=4 females) completed a familiarization session and two all-out critical force tests on different days. During each trial, participants completed 24 repetitions of 7s right-handed, maximal effort hangs from a 20mm edge interspersed with 3 s rest. The end-test force (EF; i.e., critical force), impulse above EF (IEF), and peak force achieved during the test were analyzed with paired t-tests to determine differences between trials. Intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman analysis were performed to quantify the relative and absolute reliability of the measure, respectively. The level of significance for this study was set at p<0.05. There were no significant differences between trials for any of the reported variables (P≥0.455). For EF, IEF, and peak force, ICC was 0.848, 0.820, and 0.938, respectively; and CV was 21.0%, 13.2%, and 5.6%, respectively. Bland-Altman analyses showed a mean relative bias of -2.3%, -2.8%, and -1.3%, with 95% limits of agreement (LoA) of -62.6% to 58.1%, -40.5% to 30.9%, and -17.2% to 14.6% for EF, IEF, and peak force, respectively, however linear regression revealed a significant proportional bias for EF (p = 0.026, R2 = 0.377). The reliability of this protocol was good to excellent for all parameters; however, there was larger intra-individual variability for EF and IEF. This study suggests that when using the 4-min all-out critical force test in rock climbers, coaches and athletes should be aware that there may be a trade-off between the test's practicality and the precision of its results.
Collapse
Affiliation(s)
- Zachary J McCLEAN
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, CANADA
- Department of Health and Physical Education, Mount Royal University, Calgary, AB, CANADA
| | - Keenan B MacDOUGALL
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, CANADA
- Department of Health and Physical Education, Mount Royal University, Calgary, AB, CANADA
| | - Jared R Fletcher
- Department of Health and Physical Education, Mount Royal University, Calgary, AB, CANADA
| | - Saied J Aboodarda
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, CANADA
| | - Brian R Macintosh
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, CANADA
| |
Collapse
|
85
|
Dearing CG, Paton CD. Is Stryd critical power a meaningful parameter for runners? Biol Sport 2023; 40:657-664. [PMID: 37398957 PMCID: PMC10286607 DOI: 10.5114/biolsport.2023.118025] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 05/09/2022] [Accepted: 06/17/2022] [Indexed: 09/16/2023] Open
Abstract
Stryd is a foot pod that reliably estimates running power. Our objectives were to examine the efficacy of the website-generated Stryd critical power (CPSTRYD) as a meaningful parameter for runners. 20 runners performed their regular training while wearing Stryd for a minimum of 6 weeks to generate CPSTRYD. Runners completed laboratory graded exercise testing, and outdoor 1500 m and 5000 m time trails. CPSTRYD was most similar to the second ventilatory threshold (VT2) or the onset of blood lactate accumulation (OBLA) and is highly predictive of running performance. Stryd ground contact time (GCT) was a predictor of performance when comparing runners at the same submaximal treadmill speed. CPSTRYD generated from outdoor running is equivalent to that calculated using an established CP model. However, variance between different methods of CP estimation must be a consideration for runners and coaches. Stryd offers meaningful data for runners including a realistic estimate of CP.
Collapse
Affiliation(s)
- Chey G. Dearing
- The Eastern Institute of Technology, School of Health and Sport Science and School of Nursing, Napier, New Zealand
| | - Carl D. Paton
- The Eastern Institute of Technology, School of Health and Sport Science, Napier, New Zealand
| |
Collapse
|
86
|
Sanchez-Jimenez JL, Lorente-Casaus C, Jimenez-Perez I, Gandía-Soriano A, Carpes FP, Priego-Quesada JI. Acute effects of fatigue on internal and external load variables determining cyclists' power profile. J Sports Sci 2023:1-10. [PMID: 37379499 DOI: 10.1080/02640414.2023.2227523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 06/12/2023] [Indexed: 06/30/2023]
Abstract
The aim of the present study was to determine whether fatigue affects internal and external load variables determining power profile in cyclists. Ten cyclists performed outdoor power profile tests (lasting 1-, 5 and 20-min) on two consecutive days, subject either to a fatigued condition or not. Fatigue was induced by undertaking an effort (10-min at 95% of average power output obtained in a 20-min effort followed by 1-min maximum effort) until the power output decreased by 20% compared to the 1-min power output. Fatigued condition decreased power output (p < 0.05, 1-min: 9.0 ± 3.8%; 5-min: 5.9 ± 2.5%; 20-min: 4.1 ± 1.9%) and cadence in all test durations, without differences in torque. Lactate decreased in longer efforts when a fatigue protocol had previously been conducted (e.g., 20-min: 8.6 ± 3.0 vs. 10.9 ± 2.7, p < 0.05). Regression models (r2 ≥ 0.95, p < 0.001) indicated that a lower variation in load variables of 20-min in fatigued condition compared with the non-fatigued state resulted in a lower decrease in critical power after the fatigue protocol. The results suggest that fatigued condition on power was more evident in shorter efforts and seemed to rely more on a decrease in cadence than on torque.
Collapse
Affiliation(s)
- Jose Luis Sanchez-Jimenez
- Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Carlos Lorente-Casaus
- Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Irene Jimenez-Perez
- Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Alexis Gandía-Soriano
- Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Felipe P Carpes
- Applied Neuromechanics Group, Laboratory of Neuromechanics, Federal University of Pampa, Uruguaiana, RS, Brazil
| | - Jose Ignacio Priego-Quesada
- Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| |
Collapse
|
87
|
Massini DA, Espada MC, Macedo AG, Santos FJ, Castro EA, Ferreira CC, Robalo RAM, Dias AAP, Almeida TAF, Pessôa Filho DM. Oxygen Uptake Kinetics and Time Limit at Maximal Aerobic Workload in Tethered Swimming. Metabolites 2023; 13:773. [PMID: 37512480 PMCID: PMC10385165 DOI: 10.3390/metabo13070773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 05/29/2023] [Accepted: 06/19/2023] [Indexed: 07/30/2023] Open
Abstract
This study aimed to apply an incremental tethered swimming test (ITT) with workloads (WL) based on individual rates of front crawl mean tethered force (Fmean) for the identification of the upper boundary of heavy exercise (by means of respiratory compensation point, RCP), and therefore to describe oxygen uptake kinetics (VO2k) and time limit (tLim) responses to WL corresponding to peak oxygen uptake (WLVO2peak). Sixteen swimmers of both sexes (17.6 ± 3.8 years old, 175.8 ± 9.2 cm, and 68.5 ± 10.6 kg) performed the ITT until exhaustion, attached to a weight-bearing pulley-rope system for the measurements of gas exchange threshold (GET), RCP, and VO2peak. The WL was increased by 5% from 30 to 70% of Fmean at every minute, with Fmean being measured by a load cell attached to the swimmers during an all-out 30 s front crawl bout. The pulmonary gas exchange was sampled breath by breath, and the mathematical description of VO2k used a first-order exponential with time delay (TD) on the average of two rest-to-work transitions at WLVO2peak. The mean VO2peak approached 50.2 ± 6.2 mL·kg-1·min-1 and GET and RCP attained (respectively) 67.4 ± 7.3% and 87.4 ± 3.4% VO2peak. The average tLim was 329.5 ± 63.6 s for both sexes, and all swimmers attained VO2peak (100.4 ± 3.8%) when considering the primary response of VO2 (A1' = 91.8 ± 6.7%VO2peak) associated with the VO2 slow component (SC) of 10.7 ± 6.7% of end-exercise VO2, with time constants of 24.4 ± 9.8 s for A1' and 149.3 ± 29.1 s for SC. Negative correlations were observed for tLim to VO2peak, WLVO2peak, GET, RCP, and EEVO2 (r = -0.55, -0.59, -0.58, -0.53, and -0.50). Thus, the VO2k during tethered swimming at WLVO2peak reproduced the physiological responses corresponding to a severe domain. The findings also demonstrated that tLim was inversely related to aerobic conditioning indexes and to the ability to adjust oxidative metabolism to match target VO2 demand during exercise.
Collapse
Affiliation(s)
- Danilo A Massini
- Graduate Programme in Human Development and Technology, Institute of Biology, São Paulo State University (UNESP), Campus at Rio Claro, São Paulo 13506-900, Brazil
- Physical Education Department, School of Sciences (FC), Universidade Estadual Paulista (UNESP), Campus at Bauru, São Paulo 17033-360, Brazil
| | - Mário C Espada
- Instituto Politécnico de Setúbal, Escola Superior de Educação, 2914-504 Setúbal, Portugal
- Life Quality Research Centre (LQRC-CIEQV, Leiria), Complexo Andaluz, Apartado, 2040-413 Rio Maior, Portugal
- CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, 1499-002 Cruz Quebrada, Portugal
| | - Anderson G Macedo
- Graduate Programme in Human Development and Technology, Institute of Biology, São Paulo State University (UNESP), Campus at Rio Claro, São Paulo 13506-900, Brazil
- Physical Education Department, School of Sciences (FC), Universidade Estadual Paulista (UNESP), Campus at Bauru, São Paulo 17033-360, Brazil
| | - Fernando J Santos
- Instituto Politécnico de Setúbal, Escola Superior de Educação, 2914-504 Setúbal, Portugal
- Life Quality Research Centre (LQRC-CIEQV, Leiria), Complexo Andaluz, Apartado, 2040-413 Rio Maior, Portugal
- Faculdade de Motricidade Humana, Universidade de Lisboa, 1499-002 Cruz Quebrada, Portugal
| | - Eliane A Castro
- Graduate Programme in Human Development and Technology, Institute of Biology, São Paulo State University (UNESP), Campus at Rio Claro, São Paulo 13506-900, Brazil
- Physical Education Department, School of Sciences (FC), Universidade Estadual Paulista (UNESP), Campus at Bauru, São Paulo 17033-360, Brazil
- LFE Research Group, Universidad Politécnica de Madrid (UPM), 28040 Madrid, Spain
| | - Cátia C Ferreira
- Instituto Politécnico de Setúbal, Escola Superior de Educação, 2914-504 Setúbal, Portugal
- Research Group in Optimization of Training and Sport Performance (GOERD), Faculty of Sports Sciences, University of Extremadura, 10003 Caceres, Spain
| | - Ricardo A M Robalo
- Instituto Politécnico de Setúbal, Escola Superior de Educação, 2914-504 Setúbal, Portugal
- Faculdade de Motricidade Humana, Universidade de Lisboa, 1499-002 Cruz Quebrada, Portugal
| | - Amândio A P Dias
- Egas Moniz Center for Interdisciplinary Research (CiiEM), Egas Moniz School of Health & Science, 2829-511 Caparica, Portugal
| | - Tiago A F Almeida
- Graduate Programme in Human Development and Technology, Institute of Biology, São Paulo State University (UNESP), Campus at Rio Claro, São Paulo 13506-900, Brazil
- Physical Education Department, School of Sciences (FC), Universidade Estadual Paulista (UNESP), Campus at Bauru, São Paulo 17033-360, Brazil
- CIPER, Faculdade de Motricidade Humana, Universidade de Lisboa, 1499-002 Cruz Quebrada, Portugal
| | - Dalton M Pessôa Filho
- Graduate Programme in Human Development and Technology, Institute of Biology, São Paulo State University (UNESP), Campus at Rio Claro, São Paulo 13506-900, Brazil
- Physical Education Department, School of Sciences (FC), Universidade Estadual Paulista (UNESP), Campus at Bauru, São Paulo 17033-360, Brazil
| |
Collapse
|
88
|
TILLER NICHOLASB, PORSZASZ JANOS, CASABURI RICHARD, ROSSITER HARRYB, FERGUSON CARRIE. Critical Power and Respiratory Compensation Point Are Not Equivalent in Patients with COPD. Med Sci Sports Exerc 2023; 55:1097-1104. [PMID: 36633582 PMCID: PMC10184810 DOI: 10.1249/mss.0000000000003124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
INTRODUCTION Several studies report that pulmonary oxygen uptake (V̇O 2 ) at the respiratory compensation point (RCP) is equivalent to the V̇O 2 at critical power (CP), suggesting that the variables can be used interchangeably to demarcate the threshold between heavy and severe intensity domains. However, if RCP is a valid surrogate for CP, their values should correspond even when assessed in patients with chronic obstructive pulmonary disease (COPD) in whom the "normal" mechanisms linking CP and RCP are impeded. The aim of this study was to compare V̇O 2 at CP with V̇O 2 at RCP in patients with COPD. METHODS Twenty-two COPD patients (14 male/8 female; forced expiratory volume in 1 s, 46% ± 17% pred) performed ramp-incremental cycle ergometry to intolerance (5-10 W·min -1 ) for the determination of gas exchange threshold (GET) and RCP. CP was calculated from the asymptote of the hyperbolic power-duration relationship from 3-5 constant-power exercise tests to intolerance. CP was validated with a 20-min constant-power ride. RESULTS GET was identified in 20 of 22 patients at a V̇O 2 of 0.93 ± 0.18 L·min -1 (75% ± 13% V̇O 2peak ), whereas RCP was identified in just 3 of 22 patients at a V̇O 2 of 1.40 ± 0.39 L·min -1 (85% ± 2% V̇O 2peak ). All patients completed constant-power trials with no difference in peak physiological responses relative to ramp-incremental exercise ( P > 0.05). CP was 46 ± 22 W, which elicited a V̇O 2 of 1.04 ± 0.29 L·min -1 (90% ± 9% V̇O 2peak ) during the validation ride. The difference in V̇O 2 at 15 and 20 min of the validation ride was 0.00 ± 0.04 L, which was not different from a hypothesized mean of 0 ( P = 0.856), thereby indicating a V̇O 2 steady state. CONCLUSIONS In COPD patients, who present with cardiopulmonary and/or respiratory-mechanical dysfunction, CP can be determined in the absence of RCP. Accordingly, CP and RCP are not equivalent in this group.
Collapse
|
89
|
Arcidiacono DM, Lavoie EM, Potter AW, Vangala SV, Holden LD, Soucy HY, Karis AJ, Friedl KE, Santee WR, Looney DP. Peak performance and cardiometabolic responses of modern US army soldiers during heavy, fatiguing vest-borne load carriage. APPLIED ERGONOMICS 2023; 109:103985. [PMID: 36764233 DOI: 10.1016/j.apergo.2023.103985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 01/06/2023] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
INTRODUCTION Physiological limits imposed by vest-borne loads must be defined for optimal performance monitoring of the modern dismounted warfighter. PURPOSE To evaluate how weighted vests affect locomotion economy and relative cardiometabolic strain during military load carriage while identifying key physiological predictors of exhaustion limits. METHODS Fifteen US Army soldiers (4 women, 11 men; age, 26 ± 8 years; height, 173 ± 10 cm; body mass (BM), 79 ± 16 kg) performed four incremental walking tests with different vest loads (0, 22, 44, or 66% BM). We examined the effects of vest-borne loading on peak walking speed, the physiological costs of transport, and relative work intensity. We then sought to determine which of the cardiometabolic indicators (oxygen uptake, heart rate, respiration rate) was most predictive of task failure. RESULTS Peak walking speed significantly decreased with successively heavier vest loads (p < 0.01). Physiological costs per kilometer walked were significantly higher with added vest loads for each measure (p < 0.05). Relative oxygen uptake and heart rate were significantly higher during the loaded trials than the 0% BM trial (p < 0.01) yet not different from one another (p > 0.07). Conversely, respiration rate was significantly higher with the heavier load in every comparison (p < 0.01). Probability modeling revealed heart rate as the best predictor of task failure (marginal R2, 0.587, conditional R2, 0.791). CONCLUSION Heavy vest-borne loads cause exceptional losses in performance capabilities and increased physiological strain during walking. Heart rate provides a useful non-invasive indicator of relative intensity and task failure during military load carriage.
Collapse
Affiliation(s)
- Danielle M Arcidiacono
- United States Army Research Institute of Environmental Medicine (USARIEM), 10 General Greene Avenue, Natick, MA, 01760, USA; Oak Ridge Institute for Science and Education (ORISE), 1299 Bethel Valley Rd, Oak Ridge, TN, 37830, USA
| | - Elizabeth M Lavoie
- United States Army Research Institute of Environmental Medicine (USARIEM), 10 General Greene Avenue, Natick, MA, 01760, USA; Oak Ridge Institute for Science and Education (ORISE), 1299 Bethel Valley Rd, Oak Ridge, TN, 37830, USA; University at Buffalo, SUNY, 211 Kimball Tower, Buffalo, NY, 14214, USA
| | - Adam W Potter
- United States Army Research Institute of Environmental Medicine (USARIEM), 10 General Greene Avenue, Natick, MA, 01760, USA
| | - Sai V Vangala
- United States Army Research Institute of Environmental Medicine (USARIEM), 10 General Greene Avenue, Natick, MA, 01760, USA
| | - Lucas D Holden
- United States Army Research Institute of Environmental Medicine (USARIEM), 10 General Greene Avenue, Natick, MA, 01760, USA; Oak Ridge Institute for Science and Education (ORISE), 1299 Bethel Valley Rd, Oak Ridge, TN, 37830, USA
| | - Hope Y Soucy
- United States Army Research Institute of Environmental Medicine (USARIEM), 10 General Greene Avenue, Natick, MA, 01760, USA; Oak Ridge Institute for Science and Education (ORISE), 1299 Bethel Valley Rd, Oak Ridge, TN, 37830, USA
| | - Anthony J Karis
- United States Army Research Institute of Environmental Medicine (USARIEM), 10 General Greene Avenue, Natick, MA, 01760, USA
| | - Karl E Friedl
- United States Army Research Institute of Environmental Medicine (USARIEM), 10 General Greene Avenue, Natick, MA, 01760, USA
| | - William R Santee
- United States Army Research Institute of Environmental Medicine (USARIEM), 10 General Greene Avenue, Natick, MA, 01760, USA
| | - David P Looney
- United States Army Research Institute of Environmental Medicine (USARIEM), 10 General Greene Avenue, Natick, MA, 01760, USA.
| |
Collapse
|
90
|
King DG, Stride E, Mendis J, Gurton WH, Macrae H, Jones L, Hunt J. A Double-Blind, Randomized, Placebo-Controlled Pilot Study examining an Oxygen Nanobubble Beverage for 16.1-km Time Trial and Repeated Sprint Cycling Performance. J Diet Suppl 2023; 21:167-181. [PMID: 37127913 DOI: 10.1080/19390211.2023.2203738] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
There is growing interest of ergogenic aids that deliver supplemental oxygen during exercise and recovery, however, breathing supplemental oxygen via specialist facemasks is often not feasible. Therefore, this study investigated the effect of an oxygen-nanobubble beverage during submaximal and repeated sprint cycling. In a double-blind, randomized, placebo-controlled study, 10 male cyclists (peak aerobic capacity, 56.9 ± 6.1 mL·kg-1·min-1; maximal aerobic power, 385 ± 25 W) completed submaximal or maximal exercise after consuming an oxygen-nanobubble (O2) or placebo (PLA) beverage. Submaximal trials comprised 30-min of steady-state cycling at 60% peak aerobic capacity and 16.1-km time-trial (TT). Maximal trials involved 4 × 30 s Wingate tests interspersed by 4-min recovery. Time-to-completion during the 16.1-km TT was 2.4% faster after O2 compared with PLA (95% CI = 0.7-4.0%, p = 0.010, d = 0.41). Average power for the 16.1-km TT was 4.1% higher for O2 vs. PLA (95% CI = 2.1-7.3%, p = 0.006, d = 0.28). Average peak power during the repeated Wingate tests increased by 7.1% for O2 compared with PLA (p = 0.002, d = 0.58). An oxygen-nanobubble beverage improves performance during submaximal and repeated sprint cycling, therefore may provide a practical and effective ergogenic aid for competitive cyclists.
Collapse
Affiliation(s)
- David G King
- Department of Nutritional Sciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK
| | - Eleanor Stride
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK
| | - Jeewaka Mendis
- Department of Nutritional Sciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK
| | - William H Gurton
- Department of Nutritional Sciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK
| | - Heather Macrae
- Department of Nutritional Sciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK
| | - Louise Jones
- Department of Nutritional Sciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK
| | - Julie Hunt
- Department of Nutritional Sciences, Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK
| |
Collapse
|
91
|
Fulton TJ, Sundberg CW, Arney BE, Hunter SK. Sex Differences in the Speed-Duration Relationship of Elite Runners across the Lifespan. Med Sci Sports Exerc 2023; 55:911-919. [PMID: 36728809 PMCID: PMC10106388 DOI: 10.1249/mss.0000000000003112] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE To determine if the speed-duration relationship is altered with age and sex of elite Master's runners. METHODS The world's top 10 performances for men and women in three events (800, 1500, and 5000 m) across six age groups (18-34 yr, 40-49 yr, 50-59 yr, 60-69 yr, 70-79 yr, and 80-89 yr) were analyzed from public data to establish theoretical models of the speed-duration relationship. Critical speed (CS) and the curvature constant ( D ') were estimated by fitting the average speeds and performance times with a two-parameter hyperbolic model. RESULTS Critical speed expressed relative to the 18- to 34-yr-olds, declined with age (92.2% [40-49] to 55.2% [80-89]; P < 0.001), and absolute CS was higher in men than women within each age group ( P < 0.001). The percent difference in CS between the men and women progressively increased across age groups (10.8% [18-34] to 15.5% [80-89]). D ' was lower in women than men in the 60-69 yr, 70-79 yr, and 80-89 yr age groups ( P < 0.001), but did not differ in the 18-34 yr, 40-49 yr, or 50-59 yr age groups. CONCLUSIONS Critical speed progressively decreased with age, likely due to age-related decrements in several physiological systems that cause reduced aerobic capacity. The mechanism for the larger sex difference in CS in the older age groups is unknown but may indicate physiological differences that occur with aging and/or historical sociological factors that have reduced participation opportunities of older female runners resulting in a more limited talent pool.
Collapse
Affiliation(s)
- Timothy J. Fulton
- Exercise Science Program, Department of Physical Therapy, Marquette University, Milwaukee, WI
| | - Christopher W. Sundberg
- Exercise Science Program, Department of Physical Therapy, Marquette University, Milwaukee, WI
- Athletic and Human Performance Research Center, Marquette University, Milwaukee, WI
| | - Blaine E. Arney
- Exercise Science Program, Department of Physical Therapy, Marquette University, Milwaukee, WI
| | - Sandra K. Hunter
- Exercise Science Program, Department of Physical Therapy, Marquette University, Milwaukee, WI
- Athletic and Human Performance Research Center, Marquette University, Milwaukee, WI
| |
Collapse
|
92
|
Burnley M. Invited review: The speed-duration relationship across the animal kingdom. Comp Biochem Physiol A Mol Integr Physiol 2023; 279:111387. [PMID: 36740171 DOI: 10.1016/j.cbpa.2023.111387] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 01/25/2023] [Accepted: 02/01/2023] [Indexed: 02/05/2023]
Abstract
The parameters of the hyperbolic speed-duration relationship (the asymptote critical speed, CS, and the curvature constant, D') provide estimates of the maximal steady state speed (CS) and the distance an animal can run, swim, or fly at speeds above CS before it is forced to slow down or stop (D'). The speed-duration relationship has been directly studied in humans, horses, mice and rats. The technical difficulties with treadmill running in dogs and the relatively short greyhound race durations means that, perhaps surprisingly, it has not been assessed in dogs. The endurance capabilities of lizards, crabs and salamanders has also been measured, and the speed-duration relationship can be calculated from these data. These analyses show that 1) raising environmental temperature from 25 °C to 40 °C in lizards can double the CS with no change in D'; 2) that lungless salamanders have an extremely low critical speed due, most likely, to O2 diffusion limitations associated with cutaneous respiration; and 3) the painted ghost crab possesses the highest endurance parameter ratio (D'/CS) yet recorded (470 s), allowing it to maintain high speeds for extended periods. Although the speed-duration relationship has not been measured in fish, the sustainable swimming speed has been quantified in a range of species and is conceptually similar to the maximal steady state in humans. The high aerobic power of birds and low metabolic cost of transport during flight permits the extreme feats of endurance observed in bird migrations. However, the parameters of the avian speed-duration relationship have not been quantified.
Collapse
Affiliation(s)
- Mark Burnley
- School of Sport, Exercise and Health Sciences, Loughborough University, Leicestershire, UK.
| |
Collapse
|
93
|
Goulding RP, Burnley M, Wüst RCI. How Priming Exercise Affects Oxygen Uptake Kinetics: From Underpinning Mechanisms to Endurance Performance. Sports Med 2023; 53:959-976. [PMID: 37010782 PMCID: PMC10115720 DOI: 10.1007/s40279-023-01832-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/27/2023] [Indexed: 04/04/2023]
Abstract
The observation that prior heavy or severe-intensity exercise speeds overall oxygen uptake ([Formula: see text]O2) kinetics, termed the "priming effect", has garnered significant research attention and its underpinning mechanisms have been hotly debated. In the first part of this review, the evidence for and against (1) lactic acidosis, (2) increased muscle temperature, (3) O2 delivery, (4) altered motor unit recruitment patterns and (5) enhanced intracellular O2 utilisation in underpinning the priming effect is discussed. Lactic acidosis and increased muscle temperature are most likely not key determinants of the priming effect. Whilst priming increases muscle O2 delivery, many studies have demonstrated that an increased muscle O2 delivery is not a prerequisite for the priming effect. Motor unit recruitment patterns are altered by prior exercise, and these alterations are consistent with some of the observed changes in [Formula: see text]O2 kinetics in humans. Enhancements in intracellular O2 utilisation likely play a central role in mediating the priming effect, probably related to elevated mitochondrial calcium levels and parallel activation of mitochondrial enzymes at the onset of the second bout. In the latter portion of the review, the implications of priming on the parameters of the power-duration relationship are discussed. The effect of priming on subsequent endurance performance depends critically upon which phases of the [Formula: see text]O2 response are altered. A reduced [Formula: see text]O2 slow component or increased fundamental phase amplitude tend to increase the work performable above critical power (i.e. W´), whereas a reduction in the fundamental phase time constant following priming results in an increased critical power.
Collapse
Affiliation(s)
- Richie P Goulding
- Laboratory for Myology, Faculty of Behavioural and Movement Sciences, Amsterdam Movement Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1108, 1081 HZ, Amsterdam, The Netherlands.
| | - Mark Burnley
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Rob C I Wüst
- Laboratory for Myology, Faculty of Behavioural and Movement Sciences, Amsterdam Movement Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1108, 1081 HZ, Amsterdam, The Netherlands
| |
Collapse
|
94
|
Poole DC, Jones AM. Critical power: a paradigm-shift for benchmarking exercise testing and prescription. Exp Physiol 2023; 108:539-540. [PMID: 36719677 PMCID: PMC10988433 DOI: 10.1113/ep091126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 01/16/2023] [Indexed: 02/01/2023]
Affiliation(s)
- David C. Poole
- Department of KinesiologyKansas State UniversityManhattanKSUSA
| | | |
Collapse
|
95
|
Meyler S, Bottoms L, Wellsted D, Muniz‐Pumares D. Variability in exercise tolerance and physiological responses to exercise prescribed relative to physiological thresholds and to maximum oxygen uptake. Exp Physiol 2023; 108:581-594. [PMID: 36710454 PMCID: PMC10103872 DOI: 10.1113/ep090878] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 12/22/2022] [Indexed: 01/31/2023]
Abstract
NEW FINDINGS What is the central question of this study? Does prescribing exercise intensity using physiological thresholds create a more homogeneous exercise stimulus than using traditional intensity anchors? What is the main finding and its importance? Prescribing exercise using physiological thresholds, notably critical power, reduced the variability in exercise tolerance and acute metabolic responses. At higher intensities, approaching or exceeding the transition from heavy to severe intensity exercise, the imprecision of using fixed %V ̇ O 2 max ${\dot V_{{{\rm{O}}_{\rm{2}}}{\rm{max}}}}$ as an intensity anchor becomes amplified. ABSTRACT The objective of this study was to determine whether the variability in exercise tolerance and physiological responses is lower when exercise is prescribed relative to physiological thresholds (THR) compared to traditional intensity anchors (TRAD). Ten individuals completed a series of maximal exercise tests and a series of moderate (MOD), heavy (HVY) and severe intensity (HIIT) exercise bouts prescribed using THR intensity anchors (critical power and gas exchange threshold) and TRAD intensity anchors (maximum oxygen uptake;V ̇ O 2 max ${\dot V_{{{\rm{O}}_{\rm{2}}}{\rm{max}}}}$ ). There were no differences in exercise tolerance or acute response variability between MODTHR and MODTRAD . All individuals completed HVYTHR but only 30% completed HVYTRAD . Compared to HVYTHR , where work rates were all below critical power, work rates in HVYTRAD exceeded critical power in 70% of individuals. There was, however, no difference in acute response variability between HVYTHR and HVYTRAD . All individuals completed HIITTHR but only 20% completed HIITTRAD . The variability in peak (F = 0.274) and average (F = 0.318) blood lactate responses was lower in HIITTHR compared to HIITTRAD . The variability in W' depletion (the finite work capacity above critical power) after the final interval bout was lower in HIITTHR compared to HIITTRAD (F = 0.305). Using physiological thresholds to prescribe exercise intensity reduced the heterogeneity in exercise tolerance and physiological responses to exercise spanning the boundary between the heavy and severe intensity domains. To increase the precision of exercise intensity prescription, it is recommended that, where possible, physiological thresholds are used in place ofV ̇ O 2 max ${\dot V_{{{\rm{O}}_{\rm{2}}}{\rm{max}}}}$ .
Collapse
Affiliation(s)
- Samuel Meyler
- School of Life and Medical SciencesUniversity of HertfordshireHatfieldUK
| | - Lindsay Bottoms
- School of Life and Medical SciencesUniversity of HertfordshireHatfieldUK
| | - David Wellsted
- School of Life and Medical SciencesUniversity of HertfordshireHatfieldUK
| | | |
Collapse
|
96
|
Hucteau E, Mallard J, Pivot X, Schott R, Pflumio C, Trensz P, Favret F, Pagano AF, Hureau TJ. Exacerbated central fatigue and reduced exercise capacity in early-stage breast cancer patients treated with chemotherapy. Eur J Appl Physiol 2023:10.1007/s00421-023-05177-5. [PMID: 36939876 DOI: 10.1007/s00421-023-05177-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Accepted: 03/07/2023] [Indexed: 03/21/2023]
Abstract
PURPOSE The present study aimed to characterize the etiology of exercise-induced neuromuscular fatigue and its consequences on the force-duration relationship to provide mechanistic insights into the reduced exercise capacity characterizing early-stage breast cancer patients. METHODS Fifteen early-stage breast cancer patients and fifteen healthy women performed 60 maximal voluntary isometric quadriceps contractions (MVCs, 3 s of contraction, 2 s of relaxation). The critical force was determined as the mean force of the last six contractions, while W' was calculated as the force impulse generated above the critical force. Quadriceps muscle activation during exercise was estimated from vastus lateralis, vastus medialis and rectus femoris EMG. Central and peripheral fatigue were quantified via changes in pre- to postexercise quadriceps voluntary activation (ΔVA) and quadriceps twitch force (ΔQTw) evoked by supramaximal electrical stimulation, respectively. RESULTS Early-stage breast cancer patients demonstrated lower MVC than controls preexercise (- 15%, P = 0.022), and this reduction persisted throughout the 60-MVC exercise (- 21%, P = 0.002). The absolute critical force was lower in patients than in controls (144 ± 29N vs. 201 ± 47N, respectively, P < 0.001), while W' was similar (P = 0.546), resulting in lower total work done (- 23%, P = 0.001). This was associated with lower muscle activation in the vastus lateralis (P < 0.001), vastus medialis (P = 0.003) and rectus femoris (P = 0.003) in patients. Immediately following exercise, ΔVA showed a greater reduction in patients compared to controls (- 21.6 ± 13.3% vs. - 12.6 ± 7.7%, P = 0.040), while ΔQTw was similar (- 60.2 ± 13.2% vs. - 52.8 ± 19.4%, P = 0.196). CONCLUSION These findings support central fatigue as a primary cause of the reduction in exercise capacity characterizing early-stage breast cancer patients treated with chemotherapy. CLINICAL TRIALS REGISTRATION No. NCT04639609-November 20, 2020.
Collapse
Affiliation(s)
- Elyse Hucteau
- Biomedicine Research Centre of Strasbourg (CRBS), Mitochondria, Oxidative Stress, and Muscular Protection Laboratory (UR 3072), Strasbourg, France
- Faculty of Sport Sciences, European Centre for Education, Research and Innovation in Exercise Physiology (CEERIPE), University of Strasbourg, 4 rue Blaise Pascal, CS 90032, 67081, Strasbourg Cedex, France
- Institute of Cancerology Strasbourg Europe (ICANS), Strasbourg, France
| | - Joris Mallard
- Biomedicine Research Centre of Strasbourg (CRBS), Mitochondria, Oxidative Stress, and Muscular Protection Laboratory (UR 3072), Strasbourg, France
- Faculty of Sport Sciences, European Centre for Education, Research and Innovation in Exercise Physiology (CEERIPE), University of Strasbourg, 4 rue Blaise Pascal, CS 90032, 67081, Strasbourg Cedex, France
- Institute of Cancerology Strasbourg Europe (ICANS), Strasbourg, France
| | - Xavier Pivot
- Institute of Cancerology Strasbourg Europe (ICANS), Strasbourg, France
| | - Roland Schott
- Institute of Cancerology Strasbourg Europe (ICANS), Strasbourg, France
| | - Carole Pflumio
- Institute of Cancerology Strasbourg Europe (ICANS), Strasbourg, France
| | - Philippe Trensz
- Institute of Cancerology Strasbourg Europe (ICANS), Strasbourg, France
| | - Fabrice Favret
- Biomedicine Research Centre of Strasbourg (CRBS), Mitochondria, Oxidative Stress, and Muscular Protection Laboratory (UR 3072), Strasbourg, France
- Faculty of Sport Sciences, European Centre for Education, Research and Innovation in Exercise Physiology (CEERIPE), University of Strasbourg, 4 rue Blaise Pascal, CS 90032, 67081, Strasbourg Cedex, France
| | - Allan F Pagano
- Biomedicine Research Centre of Strasbourg (CRBS), Mitochondria, Oxidative Stress, and Muscular Protection Laboratory (UR 3072), Strasbourg, France
- Faculty of Sport Sciences, European Centre for Education, Research and Innovation in Exercise Physiology (CEERIPE), University of Strasbourg, 4 rue Blaise Pascal, CS 90032, 67081, Strasbourg Cedex, France
| | - Thomas J Hureau
- Biomedicine Research Centre of Strasbourg (CRBS), Mitochondria, Oxidative Stress, and Muscular Protection Laboratory (UR 3072), Strasbourg, France.
- Faculty of Sport Sciences, European Centre for Education, Research and Innovation in Exercise Physiology (CEERIPE), University of Strasbourg, 4 rue Blaise Pascal, CS 90032, 67081, Strasbourg Cedex, France.
| |
Collapse
|
97
|
do Nascimento Salvador PC, Nascimento EMF, Antunes D, Guglielmo LGA, Denadai BS. Energy metabolism and muscle activation heterogeneity explain V ̇ O 2 ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}}$ slow component and muscle fatigue of cycling at different intensities. Exp Physiol 2023; 108:503-517. [PMID: 36648072 PMCID: PMC10103881 DOI: 10.1113/ep090444] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 12/13/2022] [Indexed: 01/18/2023]
Abstract
NEW FINDINGS What is the central question of this study? What are the physiological mechanisms underlying muscle fatigue and the increase in the O2 cost per unit of work during high-intensity exercise? What is the main finding and its importance? Muscle fatigue happens before, and does not explain, theV ̇ O 2 ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}}$ slow component (V ̇ O 2 sc ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}{\rm{sc}}}$ ), but they share the same origin. Muscle activation heterogeneity is associated with muscle fatigue andV ̇ O 2 sc ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}{\rm{sc}}}$ . Knowing this may improve training prescriptions for healthy people leading to improved public health outcomes. ABSTRACT This study aimed to explain theV ̇ O 2 ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}}$ slow component (V ̇ O 2 sc ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}{\rm{sc}}}$ ) and muscle fatigue during cycling at different intensities. The muscle fatigue of 16 participants was determined through maximal isokinetic effort lasting 3 s during constant work rate bouts of moderate (MOD), heavy (HVY) and very heavy intensity (VHI) exercise. Breath-by-breathV ̇ O 2 ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}}$ , near-infrared spectroscopy signals and EMG activity were analysed (thigh muscles).V ̇ O 2 sc ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}{\rm{sc}}}$ was higher during VHI exercise (∼70% vs. ∼28% ofV ̇ O 2 ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}}$ reserve in HVY). The deoxygenated haemoglobin final value during VHI exercise was higher than during HVY and MOD exercise (∼90% of HHb physiological normalization, vs. ∼82% HVY and ∼45% MOD). The muscle fatigue was greater after VHI exercise (∼22% vs. HVY ∼5%). There was no muscle fatigue after MOD exercise. The greatest magnitude of muscle fatigue occurred within 2 min (VHI ∼17%; HVY ∼9%), after which it stabilized. No significant relationship betweenV ̇ O 2 sc ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}{\rm{sc}}}$ and muscle force production was observed. The τ of muscleV ̇ O 2 ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}}$ was significantly related (R2 = 0.47) with torque decrease for VHI. Type I and II muscle fibre recruitment mainly in the rectus femoris moderately explained the muscle fatigue (R2 = 0.30 and 0.31, respectively) and theV ̇ O 2 sc ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}{\rm{sc}}}$ (R2 = 0.39 and 0.27, respectively). TheV ̇ O 2 sc ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}{\rm{sc}}}$ is also partially explained by blood lactate accumulation (R2 = 0.42). In conclusion muscle fatigue and O2 cost seem to share the same physiological cause linked with a decrease in the muscleV ̇ O 2 ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}}$ and a change in lactate accumulation. Muscle fatigue andV ̇ O 2 sc ${\dot{V}}_{{{\rm{O}}}_{\rm{2}}{\rm{sc}}}$ are associated with muscle activation heterogeneity and metabolism of different muscles activated during cycling.
Collapse
Affiliation(s)
- Paulo Cesar do Nascimento Salvador
- Physical effort LaboratorySports CentreFederal University of Santa CatarinaFlorianopolisBrazil
- Leonardo da Vinci University – Uniasselvi/VITRU EducationIndaialBrazil
| | | | - Diego Antunes
- Physical effort LaboratorySports CentreFederal University of Santa CatarinaFlorianopolisBrazil
| | | | - Benedito Sérgio Denadai
- Physical effort LaboratorySports CentreFederal University of Santa CatarinaFlorianopolisBrazil
- Human Performance LaboratorySão Paulo State UniversityRio ClaroBrazil
| |
Collapse
|
98
|
Hunter B, Karsten B, Greenhalgh A, Burnley M, Muniz-Pumares D. The Application of non-linear methods to quantify changes to movement dynamics during running: A scoping review. J Sports Sci 2023; 41:481-494. [PMID: 37330658 DOI: 10.1080/02640414.2023.2225014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 06/05/2023] [Indexed: 06/19/2023]
Abstract
The aim of this scoping review was to evaluate research approaches that quantify changes to non-linear movement dynamics during running in response to fatigue, different speeds, and fitness levels. PubMed and Scopus were used to identify appropriate research articles. After the selection of eligible studies, study details and participant characteristics were extracted and tabulated to identify methodologies and findings. Twenty-seven articles were included in the final analysis. To evaluate non-linearities in the time series, a range of approaches were identified including motion capture, accelerometery, and foot switches. Common methods of analysis included measures of fractal scaling, entropy, and local dynamic stability. Conflicting findings were evident when studies examined non-linear features in fatigued states when compared to non-fatigued. More pronounced alterations to movement dynamics are evident when running speed is changed markedly. Greater fitness levels resulted in more stable and predictable running patterns. The mechanisms by which these changes are underpinned require further examination. These could include the physiological demand of running, biomechanical constraints of the runner, and the attentional demands of the task. Moreover, the practical implications are yet to be elucidated. This review has identified gaps in the literature which should be addressed for further understanding of the field.
Collapse
Affiliation(s)
- Ben Hunter
- School of Life and Medical Sciences, University of Hertfordshire, Hatfield, UK
- School of Human Sciences, London Metropolitan University, London, UK
| | - Bettina Karsten
- EUFH, Hochschule für Gesundheit, Soziales und Pädagogik, Berlin, Germany
| | - Andrew Greenhalgh
- School of Life and Medical Sciences, University of Hertfordshire, Hatfield, UK
| | - Mark Burnley
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough,UK
| | | |
Collapse
|
99
|
Abstract
The physiological determinants of high-intensity exercise tolerance are important for both elite human performance and morbidity, mortality and disease in clinical settings. The asymptote of the hyperbolic relation between external power and time to task failure, critical power, represents the threshold intensity above which systemic and intramuscular metabolic homeostasis can no longer be maintained. After ~ 60 years of research into the phenomenon of critical power, a clear understanding of its physiological determinants has emerged. The purpose of the present review is to critically examine this contemporary evidence in order to explain the physiological underpinnings of critical power. Evidence demonstrating that alterations in convective and diffusive oxygen delivery can impact upon critical power is first addressed. Subsequently, evidence is considered that shows that rates of muscle oxygen utilisation, inferred via the kinetics of pulmonary oxygen consumption, can influence critical power. The data reveal a clear picture that alterations in the rates of flux along every step of the oxygen transport and utilisation pathways influence critical power. It is also clear that critical power is influenced by motor unit recruitment patterns. On this basis, it is proposed that convective and diffusive oxygen delivery act in concert with muscle oxygen utilisation rates to determine the intracellular metabolic milieu and state of fatigue within the myocytes. This interacts with exercising muscle mass and motor unit recruitment patterns to ultimately determine critical power.
Collapse
|
100
|
Pogliaghi S, Teso M, Ferrari L, Boone J, Murias JM, Colosio AL. Easy Prediction of the Maximal Lactate Steady-State in Young and Older Men and Women. J Sports Sci Med 2023; 22:68-74. [PMID: 36876184 PMCID: PMC9982529 DOI: 10.52082/jssm.2023.68] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 01/15/2023] [Indexed: 01/24/2023]
Abstract
Maximal Lactate steady-state (MLSS) demarcates sustainable from unsustainable exercise and is used for evaluation/monitoring of exercise capacity. Still, its determination is physically challenging and time-consuming. This investigation aimed at validating a simple, submaximal approach based on blood lactate accumulation ([Δlactate]) at the third minute of cycling in a large cohort of men and women of different ages. 68 healthy adults (40♂, 28♀, 43 ± 17 years (range 19-78), VO2max 45 ± 11 ml-1·kg-1·min-1 (25-68)) performed 3-5 constant power output (PO) trials with a target duration of 30 minutes to determine the PO corresponding to MLSS. During each trial, [Δlactate] was calculated as the difference between the third minute and baseline. A multiple linear regression was computed to estimate MLSS based on [Δlactate], subjects` gender, age and the trial PO. The estimated MLSS was compared to the measured value by paired t-test, correlation, and Bland-Altman analysis. The group mean value of estimated MLSS was 180 ± 51 W, not significantly different from (p = 0.98) and highly correlated with (R2 = 0.89) measured MLSS (180 ± 54 watts). The bias between values was 0.17 watts, and imprecision 18.2 watts. This simple, submaximal, time- and cost-efficient test accurately and precisely predicts MLSS across different samples of healthy individuals (adjusted R2 = 0.88) and offers a practical and valid alternative to the traditional MLSS determination.
Collapse
Affiliation(s)
- Silvia Pogliaghi
- Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, Verona, Italy
| | - Massimo Teso
- Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, Verona, Italy
| | - Luca Ferrari
- Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, Verona, Italy
| | - Jan Boone
- Department of Movement and Sports Sciences, Ghent University, Ghent, Belgium
| | - Juan M Murias
- Faculty of Kinesiology, University of Calgary, Calgary, Canada
| | | |
Collapse
|