1
|
Boodhoo N, Shoja Doost J, Sharif S. Biosensors for Monitoring, Detecting, and Tracking Dissemination of Poultry-Borne Bacterial Pathogens Along the Poultry Value Chain: A Review. Animals (Basel) 2024; 14:3138. [PMID: 39518862 PMCID: PMC11545827 DOI: 10.3390/ani14213138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2024] [Revised: 10/28/2024] [Accepted: 10/30/2024] [Indexed: 11/16/2024] Open
Abstract
The poultry industry plays a crucial role in global food production, with chickens being the most widely consumed as a rich protein source. However, infectious diseases pose significant threats to poultry health, underscoring the need for rapid and accurate detection to enable timely intervention. In recent years, biosensors have emerged as essential tools to facilitate routine surveillance on poultry farms and rapid screening at slaughterhouses. These devices provide producers and veterinarians with timely information, thereby promoting proactive disease management. Biosensors have been miniaturized, and portable platforms allow for on-site testing, thereby enhancing biosecurity measures and bolstering disease surveillance networks throughout the poultry supply chain. Consequently, biosensors represent a transformative advancement in poultry disease management, offering rapid and precise detection capabilities that are vital for safeguarding poultry health and ensuring sustainable production systems. This section offers an overview of biosensors and their applications in detecting poultry diseases, with a particular emphasis on enteric pathogens.
Collapse
Affiliation(s)
- Nitish Boodhoo
- Department of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, ON N1G 2W1, Canada; (J.S.D.); (S.S.)
| | | | | |
Collapse
|
2
|
Hettiarachchi S, Cha H, Ouyang L, Mudugamuwa A, An H, Kijanka G, Kashaninejad N, Nguyen NT, Zhang J. Recent microfluidic advances in submicron to nanoparticle manipulation and separation. LAB ON A CHIP 2023; 23:982-1010. [PMID: 36367456 DOI: 10.1039/d2lc00793b] [Citation(s) in RCA: 34] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Manipulation and separation of submicron and nanoparticles are indispensable in many chemical, biological, medical, and environmental applications. Conventional technologies such as ultracentrifugation, ultrafiltration, size exclusion chromatography, precipitation and immunoaffinity capture are limited by high cost, low resolution, low purity or the risk of damage to biological particles. Microfluidics can accurately control fluid flow in channels with dimensions of tens of micrometres. Rapid microfluidics advancement has enabled precise sorting and isolating of nanoparticles with better resolution and efficiency than conventional technologies. This paper comprehensively studies the latest progress in microfluidic technology for submicron and nanoparticle manipulation. We first summarise the principles of the traditional techniques for manipulating nanoparticles. Following the classification of microfluidic techniques as active, passive, and hybrid approaches, we elaborate on the physics, device design, working mechanism and applications of each technique. We also compare the merits and demerits of different microfluidic techniques and benchmark them with conventional technologies. Concurrently, we summarise seven standard post-separation detection techniques for nanoparticles. Finally, we discuss current challenges and future perspectives on microfluidic technology for nanoparticle manipulation and separation.
Collapse
Affiliation(s)
- Samith Hettiarachchi
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Haotian Cha
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Lingxi Ouyang
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | | | - Hongjie An
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Gregor Kijanka
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Navid Kashaninejad
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Nam-Trung Nguyen
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| | - Jun Zhang
- Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland 4111, Australia.
| |
Collapse
|
3
|
Hashem A, Hossain MAM, Marlinda AR, Mamun MA, Sagadevan S, Shahnavaz Z, Simarani K, Johan MR. Nucleic acid-based electrochemical biosensors for rapid clinical diagnosis: advances, challenges, and opportunities. Crit Rev Clin Lab Sci 2022. [PMID: 34851806 DOI: 10.1016/j.apsadv.2021.100064] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Clinical diagnostic tests should be quick, reliable, simple to perform, and affordable for diagnosis and treatment of diseases. In this regard, owing to their novel properties, biosensors have attracted the attention of scientists as well as end-users. They are efficient, stable, and relatively cheap. Biosensors have broad applications in medical diagnosis, including point-of-care (POC) monitoring, forensics, and biomedical research. The electrochemical nucleic acid (NA) biosensor, the latest invention in this field, combines the sensitivity of electroanalytical methods with the inherent bioselectivity of deoxyribonucleic acid (DNA) and ribonucleic acid (RNA). The NA biosensor exploits the affinity of single-stranded DNA/RNA for its complementary strand and is used to detect complementary sequences of NA based on hybridization. After the NA component in the sensor detects the analyte, a catalytic reaction or binding event that generates an electrical signal in the transducer ensues. Since 2000, much progress has been made in this field, but there are still numerous challenges. This critical review describes the advances, challenges, and prospects of NA-based electrochemical biosensors for clinical diagnosis. It includes the basic principles, classification, sensing enhancement strategies, and applications of biosensors as well as their advantages, limitations, and future prospects, and thus it should be useful to academics as well as industry in the improvement and application of EC NA biosensors.
Collapse
Affiliation(s)
- Abu Hashem
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
- Microbial Biotechnology Division, National Institute of Biotechnology, Dhaka, Bangladesh
| | - M A Motalib Hossain
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
| | - Ab Rahman Marlinda
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
| | - Mohammad Al Mamun
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
- Department of Chemistry, Jagannath University, Dhaka, Bangladesh
| | - Suresh Sagadevan
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
| | - Zohreh Shahnavaz
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
| | - Khanom Simarani
- Department of Microbiology, Institute of Biological Sciences, Faculty of Sciences, University of Malaya, Kuala Lumpur, Malaysia
| | - Mohd Rafie Johan
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
4
|
Rezaei Z, Alemzadeh I, Vossoughi M. Design and fabrication of an electrochemical‐based nanofibrous immunosensor for detection of prostate cancer biomarker,
PSMA. POLYM ADVAN TECHNOL 2022. [DOI: 10.1002/pat.5658] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Zahra Rezaei
- Chemical and Petroleum Engineering Department Sharif University of Technology Iran
| | - Iran Alemzadeh
- Chemical and Petroleum Engineering Department Sharif University of Technology Iran
| | - Manouchehr Vossoughi
- Chemical and Petroleum Engineering Department Sharif University of Technology Iran
| |
Collapse
|
5
|
Hsieh K, Melendez JH, Gaydos CA, Wang TH. Bridging the gap between development of point-of-care nucleic acid testing and patient care for sexually transmitted infections. LAB ON A CHIP 2022; 22:476-511. [PMID: 35048928 PMCID: PMC9035340 DOI: 10.1039/d1lc00665g] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The incidence rates of sexually transmitted infections (STIs), including the four major curable STIs - chlamydia, gonorrhea, trichomoniasis and, syphilis - continue to increase globally, causing medical cost burden and morbidity especially in low and middle-income countries (LMIC). There have seen significant advances in diagnostic testing, but commercial antigen-based point-of-care tests (POCTs) are often insufficiently sensitive and specific, while near-point-of-care (POC) instruments that can perform sensitive and specific nucleic acid amplification tests (NAATs) are technically complex and expensive, especially for LMIC. Thus, there remains a critical need for NAAT-based STI POCTs that can improve diagnosis and curb the ongoing epidemic. Unfortunately, the development of such POCTs has been challenging due to the gap between researchers developing new technologies and healthcare providers using these technologies. This review aims to bridge this gap. We first present a short introduction of the four major STIs, followed by a discussion on the current landscape of commercial near-POC instruments for the detection of these STIs. We present relevant research toward addressing the gaps in developing NAAT-based STI POCT technologies and supplement this discussion with technologies for HIV and other infectious diseases, which may be adapted for STIs. Additionally, as case studies, we highlight the developmental trajectory of two different POCT technologies, including one approved by the United States Food and Drug Administration (FDA). Finally, we offer our perspectives on future development of NAAT-based STI POCT technologies.
Collapse
Affiliation(s)
- Kuangwen Hsieh
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
| | - Johan H Melendez
- Division of Infectious Diseases, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | - Charlotte A Gaydos
- Division of Infectious Diseases, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | - Tza-Huei Wang
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD 21218, USA
| |
Collapse
|
6
|
Wang J, Ma P, Kim DH, Liu BF, Demirci U. Towards Microfluidic-Based Exosome Isolation and Detection for Tumor Therapy. NANO TODAY 2021; 37:101066. [PMID: 33777166 PMCID: PMC7990116 DOI: 10.1016/j.nantod.2020.101066] [Citation(s) in RCA: 127] [Impact Index Per Article: 31.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Exosomes are a class of cell-secreted, nano-sized extracellular vesicles with a bilayer membrane structure of 30-150 nm in diameter. Their discovery and application have brought breakthroughs in numerous areas, such as liquid biopsies, cancer biology, drug delivery, immunotherapy, tissue repair, and cardiovascular diseases. Isolation of exosomes is the first step in exosome-related research and its applications. Standard benchtop exosome separation and sensing techniques are tedious and challenging, as they require large sample volumes, multi-step operations that are complex and time-consuming, requiring cumbersome and expensive instruments. In contrast, microfluidic platforms have the potential to overcome some of these limitations, owing to their high-precision processing, ability to handle liquids at a microscale, and integrability with various functional units, such as mixers, actuators, reactors, separators, and sensors. These platforms can optimize the detection process on a single device, representing a robust and versatile technique for exosome separation and sensing to attain high purity and high recovery rates with a short processing time. Herein, we overview microfluidic strategies for exosome isolation based on their hydrodynamic properties, size filtration, acoustic fields, immunoaffinity, and dielectrophoretic properties. We focus especially on advances in label-free isolation of exosomes with active biological properties and intact morphological structures. Further, we introduce microfluidic techniques for the detection of exosomal proteins and RNAs with high sensitivity, high specificity, and low detection limits. We summarize the biomedical applications of exosome-mediated therapeutic delivery targeting cancer cells. To highlight the advantages of microfluidic platforms, conventional techniques are included for comparison. Future challenges and prospects of microfluidics towards exosome isolation applications are also discussed. Although the use of exosomes in clinical applications still faces biological, technical, regulatory, and market challenges, in the foreseeable future, recent developments in microfluidic technologies are expected to pave the way for tailoring exosome-related applications in precision medicine.
Collapse
Affiliation(s)
- Jie Wang
- Canary Center at Stanford for Cancer Early Detection, Bio-Acoustic MEMS in Medicine (BAMM) Laboratory, Department of Radiology, School of Medicine Stanford University, Palo Alto, California 94304-5427, USA
- Canary Center at Stanford for Cancer Early Detection, Department of Radiology, Stanford University School of Medicine, Palo Alto, California 94305, USA
| | - Peng Ma
- Canary Center at Stanford for Cancer Early Detection, Bio-Acoustic MEMS in Medicine (BAMM) Laboratory, Department of Radiology, School of Medicine Stanford University, Palo Alto, California 94304-5427, USA
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
- Canary Center at Stanford for Cancer Early Detection, Department of Radiology, Stanford University School of Medicine, Palo Alto, California 94305, USA
| | - Daniel H Kim
- Department of Biomolecular Engineering, University of California Santa Cruz, Santa Cruz, California 95064, USA
- Canary Center at Stanford for Cancer Early Detection, Department of Radiology, Stanford University School of Medicine, Palo Alto, California 94305, USA
| | - Bi-Feng Liu
- Britton Chance Center for Biomedical Photonics at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Utkan Demirci
- Canary Center at Stanford for Cancer Early Detection, Bio-Acoustic MEMS in Medicine (BAMM) Laboratory, Department of Radiology, School of Medicine Stanford University, Palo Alto, California 94304-5427, USA
- Canary Center at Stanford for Cancer Early Detection, Department of Radiology, Stanford University School of Medicine, Palo Alto, California 94305, USA
| |
Collapse
|
7
|
Siew QY, Tan SH, Pang EL, Loh HS, Tan MTT. A graphene-based dengue immunosensor using plant-derived envelope glycoprotein domain III (EDIII) as the novel probe antigen. Analyst 2021; 146:2009-2018. [PMID: 33523052 DOI: 10.1039/d0an02219e] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The envelope glycoprotein domain III (EDIII) of dengue virus (DENV) has been recognised as the antigenic region responsible for receptor binding. In the present work, we have proposed a novel immunosensor constructed on a graphene-coated screen-printed carbon electrode (SPCE) using plant-derived EDIII as the probe antigen to target DENV IgG antibodies. The developed immunosensor demonstrated high sensitivity towards DENV IgG within a wide linear working range (125-2000 ng mL-1) under the optimised sensing conditions. The limit of detection was determined to be 22.5 ng mL-1. The immunosensor also showed high specificity towards DENV IgG, capable of differentiating DENV IgG from the antibodies of other infectious diseases including the similarly structured Zika virus (ZIKV). The ability of the immunosensor to detect dengue antibodies in serum samples was also verified by conducting tests on mouse serum samples. The proposed immunosensor was able to provide a binary (positive/negative) response towards the serum samples comparable to the conventional enzyme-linked immunosorbent assay (ELISA), indicating promising potential for realistic applications.
Collapse
Affiliation(s)
- Qi Yan Siew
- Department of Electrical and Electronic Engineering, Faculty of Science and Engineering, University of Nottingham Malaysia, Jalan Broga, 43500 Semenyih, Selangor, Malaysia.
| | | | | | | | | |
Collapse
|
8
|
Highly sensitive and specific graphene/TiO 2 impedimetric immunosensor based on plant-derived tetravalent envelope glycoprotein domain III (EDIII) probe antigen for dengue diagnosis. Biosens Bioelectron 2020; 176:112895. [PMID: 33358432 DOI: 10.1016/j.bios.2020.112895] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 11/30/2020] [Accepted: 12/02/2020] [Indexed: 12/17/2022]
Abstract
This study reports on the development of a novel impedimetric immunosensor design using plant-derived antigenic glycoprotein for the detection of dengue virus (DENV) IgG antibodies. The electrochemical immunosensor platform was constructed using screen-printed carbon electrode (SPCE) modified with graphene/titanium dioxide (G/TiO2) nanocomposite to improve the electrode in terms electrochemical performance and specific surface area. A plant-derived dengue envelope domain III (EDIII) protein was used as the antigenic probe protein in this immunosensing strategy. Under optimised sensing conditions, the immunosensor demonstrated high sensitivity towards DENV IgG in a wide linear working range (62.5-2000 ng/mL), with a limit of detection of 2.81 ng/mL. The immunosensor showed high specificity for discriminating DENV IgG against antibodies of other infectious disease, including the closely related Zika virus (ZIKV). The reliability of the immunosensor in serological diagnosis was verified by challenging the immunosensor against serum samples, compared to conventional enzyme-linked immunosorbent assay (ELISA). As shown by its remarkable performance throughout the study, the devised immunosensor is proposed as a reliable and practical diagnostic tool for the serological detection of dengue in realistic applications.
Collapse
|
9
|
Eivazzadeh-Keihan R, Pashazadeh-Panahi P, Mahmoudi T, Chenab KK, Baradaran B, Hashemzaei M, Radinekiyan F, Mokhtarzadeh A, Maleki A. Dengue virus: a review on advances in detection and trends - from conventional methods to novel biosensors. Mikrochim Acta 2019; 186:329. [PMID: 31055654 DOI: 10.1007/s00604-019-3420-y] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2018] [Accepted: 04/06/2019] [Indexed: 02/06/2023]
Abstract
Dengue virus is an important arbovirus infection which transmitted by the Aedes female mosquitoes. The attempt to control and early detection of this infection is a global public health issue at present. Because of the clinical importance of its detection, the main focus of this review is on all of the methods that can offer the new diagnosis strategies. The advantages and disadvantages of reported methods have been discussed comprehensively from different aspects like biomarkers type, sensitivity, accuracy, rate of detection, possibility of commercialization, availability, limit of detection, linear range, simplicity, mechanism of detection, and ability of usage for clinical applications. The optical, electrochemical, microfluidic, enzyme linked immunosorbent assay (ELISA), and smartphone-based biosensors are the main approaches which developed for detection of different biomarkers and serotypes of Dengue virus. Future efforts in miniaturization of these methods open the horizons for development of commercial biosensors for early-diagnosis of Dengue virus infection. Graphical abstract Transmission of Dengue virus by the biting of an Aedes aegypti mosquito, the symptoms of Dengue hemorrhagic fever and the structure of Dengue virus and application of biosensors for its detection.
Collapse
Affiliation(s)
- Reza Eivazzadeh-Keihan
- Catalysts and Organic Synthesis Research Laboratory, Department of Chemistry, Iran University of Science and Technology, Tehran, 16846-13114, Iran
| | - Paria Pashazadeh-Panahi
- Department of Biochemistry and Biophysics, Metabolic Disorders Research Center, Gorgan Faculty of Medicine, Golestan University of Medical Sciences, Gorgan, Golestan Province, Iran.,Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Tohid Mahmoudi
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Karim Khanmohammadi Chenab
- Catalysts and Organic Synthesis Research Laboratory, Department of Chemistry, Iran University of Science and Technology, Tehran, 16846-13114, Iran
| | - Behzad Baradaran
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mahmoud Hashemzaei
- Department of Pharmacodynamics and Toxicology, School of Pharmacy, Zabol University of Medical Sciences, Zabol, Iran
| | - Fateme Radinekiyan
- Catalysts and Organic Synthesis Research Laboratory, Department of Chemistry, Iran University of Science and Technology, Tehran, 16846-13114, Iran
| | - Ahad Mokhtarzadeh
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran. .,Department of Biotechnology, Higher Education Institute of Rab-Rashid, Tabriz, Iran.
| | - Ali Maleki
- Catalysts and Organic Synthesis Research Laboratory, Department of Chemistry, Iran University of Science and Technology, Tehran, 16846-13114, Iran.
| |
Collapse
|
10
|
Nesakumar N, Kesavan S, Li CZ, Alwarappan S. Microfluidic Electrochemical Devices for Biosensing. JOURNAL OF ANALYSIS AND TESTING 2019. [DOI: 10.1007/s41664-019-0083-y] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
11
|
Microfluidic amperometry with two symmetric Au microelectrodes under one-way and shuttle flow conditions. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2018.11.128] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
12
|
Tabata M, Miyahara Y. Liquid biopsy in combination with solid-state electrochemical sensors and nucleic acid amplification. J Mater Chem B 2019; 7:6655-6669. [DOI: 10.1039/c9tb00718k] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Solid-state electrochemical sensors are developing as a new platform for liquid biopsy, combining detection and analysis of nucleic acids with isothermal nucleic acid amplification reactions.
Collapse
Affiliation(s)
- Miyuki Tabata
- Institute of Biomaterials and Bioengineering
- Tokyo Medical and Dental University
- Tokyo 101-0062
- Japan
| | - Yuji Miyahara
- Institute of Biomaterials and Bioengineering
- Tokyo Medical and Dental University
- Tokyo 101-0062
- Japan
| |
Collapse
|
13
|
Wongkaew N, Simsek M, Griesche C, Baeumner AJ. Functional Nanomaterials and Nanostructures Enhancing Electrochemical Biosensors and Lab-on-a-Chip Performances: Recent Progress, Applications, and Future Perspective. Chem Rev 2018; 119:120-194. [DOI: 10.1021/acs.chemrev.8b00172] [Citation(s) in RCA: 303] [Impact Index Per Article: 43.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Nongnoot Wongkaew
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Marcel Simsek
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Christian Griesche
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Antje J. Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| |
Collapse
|
14
|
Huang Y, Xu J, Liu J, Wang X, Chen B. Disease-Related Detection with Electrochemical Biosensors: A Review. SENSORS (BASEL, SWITZERLAND) 2017; 17:E2375. [PMID: 29039742 PMCID: PMC5676665 DOI: 10.3390/s17102375] [Citation(s) in RCA: 75] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Revised: 10/10/2017] [Accepted: 10/14/2017] [Indexed: 01/05/2023]
Abstract
Rapid diagnosis of diseases at their initial stage is critical for effective clinical outcomes and promotes general public health. Classical in vitro diagnostics require centralized laboratories, tedious work and large, expensive devices. In recent years, numerous electrochemical biosensors have been developed and proposed for detection of various diseases based on specific biomarkers taking advantage of their features, including sensitivity, selectivity, low cost and rapid response. This article reviews research trends in disease-related detection with electrochemical biosensors. Focus has been placed on the immobilization mechanism of electrochemical biosensors, and the techniques and materials used for the fabrication of biosensors are introduced in details. Various biomolecules used for different diseases have been listed. Besides, the advances and challenges of using electrochemical biosensors for disease-related applications are discussed.
Collapse
Affiliation(s)
- Ying Huang
- Chongqing Key Laboratory of Non-linear Circuit and Intelligent Information Processing, College of Electronic and Information Engineering, Southwest University, Chongqing 400715, China.
| | - Jin Xu
- Chongqing Key Laboratory of Non-linear Circuit and Intelligent Information Processing, College of Electronic and Information Engineering, Southwest University, Chongqing 400715, China.
| | - Junjie Liu
- Chongqing Key Laboratory of Non-linear Circuit and Intelligent Information Processing, College of Electronic and Information Engineering, Southwest University, Chongqing 400715, China.
| | - Xiangyang Wang
- CET-College of Engineering and Technology, Southwest University, Chongqing 400715, China.
| | - Bin Chen
- Chongqing Key Laboratory of Non-linear Circuit and Intelligent Information Processing, College of Electronic and Information Engineering, Southwest University, Chongqing 400715, China.
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University) Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400715, China.
| |
Collapse
|
15
|
Bruch R, Chatelle C, Kling A, Rebmann B, Wirth S, Schumann S, Weber W, Dincer C, Urban G. Clinical on-site monitoring of ß-lactam antibiotics for a personalized antibiotherapy. Sci Rep 2017; 7:3127. [PMID: 28600499 PMCID: PMC5466632 DOI: 10.1038/s41598-017-03338-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Accepted: 04/26/2017] [Indexed: 01/07/2023] Open
Abstract
An appropriate antibiotherapy is crucial for the safety and recovery of patients. Depending on the clinical conditions of patients, the required dose to effectively eradicate an infection may vary. An inadequate dosing not only reduces the efficacy of the antibiotic, but also promotes the emergence of antimicrobial resistances. Therefore, a personalized therapy is of great interest for improved patients' outcome and will reduce in long-term the prevalence of multidrug-resistances. In this context, on-site monitoring of the antibiotic blood concentration is fundamental to facilitate an individual adjustment of the antibiotherapy. Herein, we present a bioinspired approach for the bedside monitoring of free accessible ß-lactam antibiotics, including penicillins (piperacillin) and cephalosporins (cefuroxime and cefazolin) in untreated plasma samples. The introduced system combines a disposable microfluidic chip with a naturally occurring penicillin-binding protein, resulting in a high-performance platform, capable of gauging very low antibiotic concentrations (less than 6 ng ml-1) from only 1 µl of serum. The system's applicability to a personalized antibiotherapy was successfully demonstrated by monitoring the pharmacokinetics of patients, treated with ß-lactam antibiotics, undergoing surgery.
Collapse
Affiliation(s)
- R Bruch
- Department of Microsystems Engineering, University of Freiburg, 79110, Freiburg, Germany
| | - C Chatelle
- Faculty of Biology, University of Freiburg, 79104, Freiburg, Germany.,BIOSS Centre for Biological Signalling Studies, University of Freiburg, 79104, Freiburg, Germany
| | - A Kling
- Department of Biosystems Science and Engineering, ETH Zurich, 4058, Basel, Switzerland
| | - B Rebmann
- Faculty of Biology, University of Freiburg, 79104, Freiburg, Germany.,BIOSS Centre for Biological Signalling Studies, University of Freiburg, 79104, Freiburg, Germany
| | - S Wirth
- Department of Anaesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, 79106, Freiburg, Germany
| | - S Schumann
- Department of Anaesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, 79106, Freiburg, Germany
| | - W Weber
- Faculty of Biology, University of Freiburg, 79104, Freiburg, Germany.,BIOSS Centre for Biological Signalling Studies, University of Freiburg, 79104, Freiburg, Germany
| | - C Dincer
- Department of Microsystems Engineering, University of Freiburg, 79110, Freiburg, Germany. .,Freiburg Materials Research Center, University of Freiburg, 79104, Freiburg, Germany.
| | - G Urban
- Department of Microsystems Engineering, University of Freiburg, 79110, Freiburg, Germany.,Freiburg Materials Research Center, University of Freiburg, 79104, Freiburg, Germany
| |
Collapse
|
16
|
Saem S, Zhu Y, Luu H, Moran-Mirabal J. Bench-Top Fabrication of an All-PDMS Microfluidic Electrochemical Cell Sensor Integrating Micro/Nanostructured Electrodes. SENSORS 2017; 17:s17040732. [PMID: 28362329 PMCID: PMC5421692 DOI: 10.3390/s17040732] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Revised: 03/13/2017] [Accepted: 03/27/2017] [Indexed: 01/11/2023]
Abstract
In recent years, efforts in the development of lab-on-a-chip (LoC) devices for point-of-care (PoC) applications have increased to bring affordable, portable, and sensitive diagnostics to the patients' bedside. To reach this goal, research has shifted from using traditional microfabrication methods to more versatile, rapid, and low-cost options. This work focuses on the benchtop fabrication of a highly sensitive, fully transparent, and flexible poly (dimethylsiloxane) (PDMS) microfluidic (μF) electrochemical cell sensor. The μF device encapsulates 3D structured gold and platinum electrodes, fabricated using a shape-memory polymer shrinking method, which are used to set up an on-chip electrochemical cell. The PDMS to PDMS-structured electrode bonding protocol to fabricate the μF chip was optimized and found to have sufficient bond strength to withstand up to 100 mL/min flow rates. The sensing capabilities of the on-chip electrochemical cell were demonstrated by using cyclic voltammetry to monitor the adhesion of murine 3T3 fibroblasts in the presence of a redox reporter. The charge transfer across the working electrode was reduced upon cell adhesion, which was used as the detection mechanism, and allowed the detection of as few as 24 cells. The effective utilization of simple and low cost bench-top fabrication methods could accelerate the prototyping and development of LoC technologies and bring PoC diagnostics and personalized medicine to the patients' bedside.
Collapse
Affiliation(s)
- Sokunthearath Saem
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4M1, Canada.
| | - Yujie Zhu
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4M1, Canada.
| | - Helen Luu
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4M1, Canada.
| | - Jose Moran-Mirabal
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4M1, Canada.
| |
Collapse
|
17
|
Adegoke O, Park EY. Bright luminescent optically engineered core/alloyed shell quantum dots: an ultrasensitive signal transducer for dengue virus RNA via localized surface plasmon resonance-induced hairpin hybridization. J Mater Chem B 2017; 5:3047-3058. [DOI: 10.1039/c7tb00388a] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
A plasmon-mediated fluorescence molecular beacon biosensor probe has been developed for dengue virus with high sensitivity and specificity.
Collapse
Affiliation(s)
- Oluwasesan Adegoke
- Laboratory of Biotechnology
- Research Institute of Green Science and Technology
- Shizuoka University
- Shizuoka 422-8529
- Japan
| | - Enoch Y. Park
- Laboratory of Biotechnology
- Research Institute of Green Science and Technology
- Shizuoka University
- Shizuoka 422-8529
- Japan
| |
Collapse
|
18
|
Peng W, Chen Y, Ai W, Zhang D. A Nanofluidic Biosensor Based on Nanoreplica Molding Photonic Crystal. NANOSCALE RESEARCH LETTERS 2016; 11:427. [PMID: 27664018 PMCID: PMC5035292 DOI: 10.1186/s11671-016-1644-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2016] [Accepted: 09/20/2016] [Indexed: 05/30/2023]
Abstract
A nanofluidic biosensor based on nanoreplica molding photonic crystal (PC) was proposed. UV epoxy PC was fabricated by nanoreplica molding on a master PC wafer. The nanochannels were sealed between the gratings on the PC surface and a taped layer. The resonance wavelength of PC-based nanofluidic biosensor was used for testing the sealing effect. According to the peak wavelength value of the sensor, an initial label-free experiment was realized with R6g as the analyte. When the PC-based biosensor was illuminated by a monochromatic light source with a specific angle, the resonance wavelength of the sensor will match with the light source and amplified the electromagnetic field. The amplified electromagnetic field was used to enhance the fluorescence excitation result. The enhancement effect was used for enhancing fluorescence excitation and emission when matched with the resonance condition. Alexa Fluor 635 was used as the target dye excited by 637-nm laser source on a configured photonic crystal enhanced fluorescence (PCEF) setup, and an initial PCEF enhancement factor was obtained.
Collapse
Affiliation(s)
- Wang Peng
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074 China
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA
- Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA
| | - Youping Chen
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074 China
| | - Wu Ai
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074 China
| | - Dailin Zhang
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074 China
| |
Collapse
|
19
|
Ansari MH, Hassan S, Qurashi A, Khanday FA. Microfluidic-integrated DNA nanobiosensors. Biosens Bioelectron 2016; 85:247-260. [DOI: 10.1016/j.bios.2016.05.009] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 05/02/2016] [Accepted: 05/02/2016] [Indexed: 11/28/2022]
|
20
|
Chikhaliwala P, Chandra S. Dendrimers: New tool for enhancement of electrochemiluminescent signal. J Organomet Chem 2016. [DOI: 10.1016/j.jorganchem.2016.04.017] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
21
|
Kling A, Chatelle C, Armbrecht L, Qelibari E, Kieninger J, Dincer C, Weber W, Urban G. Multianalyte Antibiotic Detection on an Electrochemical Microfluidic Platform. Anal Chem 2016; 88:10036-10043. [DOI: 10.1021/acs.analchem.6b02294] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- André Kling
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
| | - Claire Chatelle
- University of Freiburg, Faculty of Biology and Centre
for Biological Signalling Studies, Schänzlestraße 18, DE-79104 Freiburg, Germany
| | - Lucas Armbrecht
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
| | - Edvina Qelibari
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
| | - Jochen Kieninger
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
| | - Can Dincer
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
- University of Freiburg, Freiburg Materials Research
Center, Stefan-Meier-Straße
21, DE-79104 Freiburg, Germany
| | - Wilfried Weber
- University of Freiburg, Faculty of Biology and Centre
for Biological Signalling Studies, Schänzlestraße 18, DE-79104 Freiburg, Germany
| | - Gerald Urban
- University of Freiburg, Department of Microsystems
Engineering, Georges-Koehler-Allee
103, DE-79110 Freiburg, Germany
- University of Freiburg, Freiburg Materials Research
Center, Stefan-Meier-Straße
21, DE-79104 Freiburg, Germany
| |
Collapse
|
22
|
Uddin R, Burger R, Donolato M, Fock J, Creagh M, Hansen MF, Boisen A. Lab-on-a-disc agglutination assay for protein detection by optomagnetic readout and optical imaging using nano- and micro-sized magnetic beads. Biosens Bioelectron 2016; 85:351-357. [PMID: 27183287 DOI: 10.1016/j.bios.2016.05.023] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2016] [Revised: 05/02/2016] [Accepted: 05/03/2016] [Indexed: 12/17/2022]
Abstract
We present a biosensing platform for the detection of proteins based on agglutination of aptamer coated magnetic nano- or microbeads. The assay, from sample to answer, is integrated on an automated, low-cost microfluidic disc platform. This ensures fast and reliable results due to a minimum of manual steps involved. The detection of the target protein was achieved in two ways: (1) optomagnetic readout using magnetic nanobeads (MNBs); (2) optical imaging using magnetic microbeads (MMBs). The optomagnetic readout of agglutination is based on optical measurement of the dynamics of MNB aggregates whereas the imaging method is based on direct visualization and quantification of the average size of MMB aggregates. By enhancing magnetic particle agglutination via application of strong magnetic field pulses, we obtained identical limits of detection of 25pM with the same sample-to-answer time (15min 30s) using the two differently sized beads for the two detection methods. In both cases a sample volume of only 10µl is required. The demonstrated automation, low sample-to-answer time and portability of both detection instruments as well as integration of the assay on a low-cost disc are important steps for the implementation of these as portable tools in an out-of-lab setting.
Collapse
Affiliation(s)
- Rokon Uddin
- Department of Micro and Nanotechnology, Technical University of Denmark, DTU Nanotech, Building 345 East, DK-2800 Kongens Lyngby, Denmark.
| | - Robert Burger
- BluSense Diagnostics, Fruebjergvej 3, DK-2100 Copenhagen Ø, Denmark
| | - Marco Donolato
- BluSense Diagnostics, Fruebjergvej 3, DK-2100 Copenhagen Ø, Denmark
| | - Jeppe Fock
- Department of Micro and Nanotechnology, Technical University of Denmark, DTU Nanotech, Building 345 East, DK-2800 Kongens Lyngby, Denmark
| | - Michael Creagh
- BluSense Diagnostics, Fruebjergvej 3, DK-2100 Copenhagen Ø, Denmark
| | - Mikkel Fougt Hansen
- Department of Micro and Nanotechnology, Technical University of Denmark, DTU Nanotech, Building 345 East, DK-2800 Kongens Lyngby, Denmark
| | - Anja Boisen
- Department of Micro and Nanotechnology, Technical University of Denmark, DTU Nanotech, Building 345 East, DK-2800 Kongens Lyngby, Denmark
| |
Collapse
|
23
|
González E, Shepherd LM, Saunders L, Frey MW. Surface Functional Poly(lactic Acid) Electrospun Nanofibers for Biosensor Applications. MATERIALS 2016; 9:ma9010047. [PMID: 28787847 PMCID: PMC5456551 DOI: 10.3390/ma9010047] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Revised: 01/05/2016] [Accepted: 01/07/2016] [Indexed: 11/28/2022]
Abstract
In this work, biotin surface functionalized hydrophilic non-water-soluble biocompatible poly(lactic acid) (PLA) nanofibers are created for their potential use as biosensors. Varying concentrations of biotin (up to 18 weight total percent (wt %)) were incorporated into PLA fibers together with poly(lactic acid)-block-poly(ethylene glycol) (PLA-b-PEG) block polymers. While biotin provided surface functionalization, PLA-b-PEG provided hydrophilicity to the final fibers. Morphology and surface-available biotin of the final fibers were studied by Field Emission Scanning Electron Microscopy (FESEM) and competitive colorimetric assays. The incorporation of PLA-b-PEG block copolymers not only decreased fiber diameters but also dramatically increased the amount of biotin available at the fiber surface able to bind avidin. Finally, fiber water stability tests revealed that both biotin and PLA-b-PEG, migrated to the aqueous phase after relatively extended periods of water exposure. The functional hydrophilic nanofiber created in this work shows a potential application as a biosensor for point-of-care diagnostics.
Collapse
Affiliation(s)
- Edurne González
- Department of Fiber Science and Apparel Design, Cornell University, Ithaca, NY 14853, USA.
| | - Larissa M Shepherd
- Department of Fiber Science and Apparel Design, Cornell University, Ithaca, NY 14853, USA.
| | - Laura Saunders
- Chemical and Biological Engineering Department, University at Buffalo, Buffalo, NY 14261, USA.
| | - Margaret W Frey
- Department of Fiber Science and Apparel Design, Cornell University, Ithaca, NY 14853, USA.
| |
Collapse
|
24
|
Cobo Solis AK, Mariano Correa N, Molina PG. Electrochemical and photophysical behavior of 1-naphthol in benzyl-n-hexadecyldimethylammonium 1,4-bis(2-ethylhexyl)sulfosuccinate large unilamellar vesicles. Phys Chem Chem Phys 2016; 18:15645-53. [DOI: 10.1039/c6cp01979j] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The behavior of 1-naphthol and its partition process in LUVs formed from a new catanionic surfactant were studied by electrochemical and spectroscopic techniques.
Collapse
Affiliation(s)
- Airam K. Cobo Solis
- Departamento de Química
- Facultad de Ciencias Exactas
- Físico-Químicas y Naturales
- Universidad Nacional de Río Cuarto
- Río Cuarto
| | - N. Mariano Correa
- Departamento de Química
- Facultad de Ciencias Exactas
- Físico-Químicas y Naturales
- Universidad Nacional de Río Cuarto
- Río Cuarto
| | - Patricia G. Molina
- Departamento de Química
- Facultad de Ciencias Exactas
- Físico-Químicas y Naturales
- Universidad Nacional de Río Cuarto
- Río Cuarto
| |
Collapse
|
25
|
Parkash O, Shueb RH. Diagnosis of Dengue Infection Using Conventional and Biosensor Based Techniques. Viruses 2015; 7:5410-27. [PMID: 26492265 PMCID: PMC4632385 DOI: 10.3390/v7102877] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Revised: 08/01/2015] [Accepted: 09/09/2015] [Indexed: 12/12/2022] Open
Abstract
Dengue is an arthropod-borne viral disease caused by four antigenically different serotypes of dengue virus. This disease is considered as a major public health concern around the world. Currently, there is no licensed vaccine or antiviral drug available for the prevention and treatment of dengue disease. Moreover, clinical features of dengue are indistinguishable from other infectious diseases such as malaria, chikungunya, rickettsia and leptospira. Therefore, prompt and accurate laboratory diagnostic test is urgently required for disease confirmation and patient triage. The traditional diagnostic techniques for the dengue virus are viral detection in cell culture, serological testing, and RNA amplification using reverse transcriptase PCR. This paper discusses the conventional laboratory methods used for the diagnosis of dengue during the acute and convalescent phase and highlights the advantages and limitations of these routine laboratory tests. Subsequently, the biosensor based assays developed using various transducers for the detection of dengue are also reviewed.
Collapse
Affiliation(s)
- Om Parkash
- Department of Medical Microbiology and Parasitology, School of Medical Science, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia.
| | - Rafidah Hanim Shueb
- Department of Medical Microbiology and Parasitology, School of Medical Science, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia.
| |
Collapse
|
26
|
Hsieh K, Ferguson BS, Eisenstein M, Plaxco KW, Soh HT. Integrated electrochemical microsystems for genetic detection of pathogens at the point of care. Acc Chem Res 2015; 48:911-20. [PMID: 25785632 DOI: 10.1021/ar500456w] [Citation(s) in RCA: 103] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The capacity to achieve rapid, sensitive, specific, quantitative, and multiplexed genetic detection of pathogens via a robust, portable, point-of-care platform could transform many diagnostic applications. And while contemporary technologies have yet to effectively achieve this goal, the advent of microfluidics provides a potentially viable approach to this end by enabling the integration of sophisticated multistep biochemical assays (e.g., sample preparation, genetic amplification, and quantitative detection) in a monolithic, portable device from relatively small biological samples. Integrated electrochemical sensors offer a particularly promising solution to genetic detection because they do not require optical instrumentation and are readily compatible with both integrated circuit and microfluidic technologies. Nevertheless, the development of generalizable microfluidic electrochemical platforms that integrate sample preparation and amplification as well as quantitative and multiplexed detection remains a challenging and unsolved technical problem. Recognizing this unmet need, we have developed a series of microfluidic electrochemical DNA sensors that have progressively evolved to encompass each of these critical functionalities. For DNA detection, our platforms employ label-free, single-step, and sequence-specific electrochemical DNA (E-DNA) sensors, in which an electrode-bound, redox-reporter-modified DNA "probe" generates a current change after undergoing a hybridization-induced conformational change. After successfully integrating E-DNA sensors into a microfluidic chip format, we subsequently incorporated on-chip genetic amplification techniques including polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) to enable genetic detection at clinically relevant target concentrations. To maximize the potential point-of-care utility of our platforms, we have further integrated sample preparation via immunomagnetic separation, which allowed the detection of influenza virus directly from throat swabs and developed strategies for the multiplexed detection of related bacterial strains from the blood of septic mice. Finally, we developed an alternative electrochemical detection platform based on real-time LAMP, which not is only capable of detecting across a broad dynamic range of target concentrations, but also greatly simplifies quantitative measurement of nucleic acids. These efforts represent considerable progress toward the development of a true sample-in-answer-out platform for genetic detection of pathogens at the point of care. Given the many advantages of these systems, and the growing interest and innovative contributions from researchers in this field, we are optimistic that iterations of these systems will arrive in clinical settings in the foreseeable future.
Collapse
Affiliation(s)
- Kuangwen Hsieh
- Department of Mechanical Engineering, ‡Institute
for Collaborative Biotechnologies, §Interdepartmental Program in Biomolecular
Science and Engineering, ∥Department of Chemistry and Biochemistry, and ⊥Materials
Department, University of California, Santa Barbara, Santa Barbara, California 93106, United States
| | - B. Scott Ferguson
- Department of Mechanical Engineering, ‡Institute
for Collaborative Biotechnologies, §Interdepartmental Program in Biomolecular
Science and Engineering, ∥Department of Chemistry and Biochemistry, and ⊥Materials
Department, University of California, Santa Barbara, Santa Barbara, California 93106, United States
| | - Michael Eisenstein
- Department of Mechanical Engineering, ‡Institute
for Collaborative Biotechnologies, §Interdepartmental Program in Biomolecular
Science and Engineering, ∥Department of Chemistry and Biochemistry, and ⊥Materials
Department, University of California, Santa Barbara, Santa Barbara, California 93106, United States
| | - Kevin W. Plaxco
- Department of Mechanical Engineering, ‡Institute
for Collaborative Biotechnologies, §Interdepartmental Program in Biomolecular
Science and Engineering, ∥Department of Chemistry and Biochemistry, and ⊥Materials
Department, University of California, Santa Barbara, Santa Barbara, California 93106, United States
| | - H. Tom Soh
- Department of Mechanical Engineering, ‡Institute
for Collaborative Biotechnologies, §Interdepartmental Program in Biomolecular
Science and Engineering, ∥Department of Chemistry and Biochemistry, and ⊥Materials
Department, University of California, Santa Barbara, Santa Barbara, California 93106, United States
| |
Collapse
|
27
|
|
28
|
|
29
|
Faure M, Pallandre A, Chebil S, Le Potier I, Taverna M, Tribollet B, Deslouis C, Haghiri-Gosnet AM, Gamby J. Improved electrochemical detection of a transthyretin synthetic peptide in the nanomolar range with a two-electrode system integrated in a glass/PDMS microchip. LAB ON A CHIP 2014; 14:2800-2805. [PMID: 24902035 DOI: 10.1039/c4lc00240g] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
An alternative to a three-electrode set-up for electrochemical detection and analysis in microfluidic chips is described here. The design of the electrochemical sensor consists of the surface of the glass substrate covered with a PDMS block which bears the microfluidic channels. A band microelectrode which acts as a working electrode surrounded by a large counter electrode is obtained at the micrometric level to propose a simple and efficient sensing area for on-a-chip analysis. The counter-electrode with a surface area about 22-fold greater than the working-microelectrode can also be considered as a pseudo reference since its current density is low and thus limits the potential variations around the rest potential. To this purpose, the [Fe(III)(CN)₆]³⁻/[Fe(II)(CN)₆]⁴⁻ redox couple was used in order to set a reference potential at 0 V since both electrodes were platinum. The electrochemical microchip performance was characterized using differential pulse voltammetric (DPV) detection and quantification of the optically multi-labelled transthyretin synthetic peptide mimicking a tryptic fragment of interest for the diagnosis of familial transthyretin amyloidosis (ATTR). The limit of detection of the peptide by the working microelectrode was 25 nM, a value 100-fold lower than the one reported with conventional capillary electrophoresis coupled with laser-induced fluorescence under the same analytical conditions.
Collapse
|
30
|
Wong WR, Krupin O, Sekaran SD, Mahamd Adikan FR, Berini P. Serological diagnosis of dengue infection in blood plasma using long-range surface plasmon waveguides. Anal Chem 2014; 86:1735-43. [PMID: 24410440 DOI: 10.1021/ac403539k] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We present a compact, cost-effective, label-free, real-time biosensor based on long-range surface plasmon polariton (LRSPP) gold (Au) waveguides for the detection of dengue-specific immunoglobulin M (IgM) antibody, and we demonstrate detection in actual patient blood plasma samples. Two surface functionalization approaches are proposed and demonstrated: a dengue virus serotype 2 (DENV-2) functionalized surface to capture dengue-specific IgM antibody in blood plasma and the reverse, a blood plasma functionalized surface to capture DENV-2. The results obtained via these two surface functionalization approaches are comparable to, or of greater quality, than those collected by conventional IgM antibody capture enzyme linked immunosorbent assay (MAC-ELISA). Our second functionalization approach was found to minimize nonspecific binding, thus improving the sensitivity and accuracy of the test. We also demonstrate reuse of the biosensors by regenerating the sensing surface down to the virus (or antibody) level or down to the bare Au.
Collapse
Affiliation(s)
- Wei Ru Wong
- Photonics Research Group, Department of Electrical Engineering, Faculty of Engineering, University of Malaya , 50603 Kuala Lumpur, Malaysia
| | | | | | | | | |
Collapse
|
31
|
Damhorst GL, Smith CE, Salm EM, Sobieraj MM, Ni H, Kong H, Bashir R. A liposome-based ion release impedance sensor for biological detection. Biomed Microdevices 2013; 15:895-905. [PMID: 23793417 PMCID: PMC4079459 DOI: 10.1007/s10544-013-9778-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Low-cost detection of pathogens and biomolecules at the point-of-care promises to revolutionize medicine through more individualized monitoring and increased accessibility to diagnostics in remote and resource-limited areas. While many approaches to biosensing are still limited by expensive components or inadequate portability, we present here an ELISA-inspired lab-on-a-chip strategy for biological detection based on liposome tagging and ion-release impedance spectroscopy. Ion-encapsulating dipalmitoylphosphatidylcholine (DPPC) liposomes can be functionalized with antibodies and are stable in deionized water yet permeabilized for ion release upon heating, making them ideal reporters for electrical biosensing of surface-immobilized antigens. We demonstrate the quantification of these liposomes by real-time impedance measurements, as well as the qualitative detection of viruses as a proof-of-concept toward a portable platform for viral load determination which can be applied broadly to the detection of pathogens and other biomolecules.
Collapse
Affiliation(s)
- Gregory L. Damhorst
- Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, 208 N Wright St, Urbana, IL 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Cartney E. Smith
- Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Eric M. Salm
- Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, 208 N Wright St, Urbana, IL 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Magdalena M. Sobieraj
- Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, 208 N Wright St, Urbana, IL 61801, USA
| | - Hengkan Ni
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Hyunjoon Kong
- Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Rashid Bashir
- Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, 208 N Wright St, Urbana, IL 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| |
Collapse
|
32
|
Nejdl L, Merlos Rodrigo MA, Kudr J, Ruttkay-Nedecky B, Konecna M, Kopel P, Zitka O, Hubalek J, Kizek R, Adam V. Liposomal nanotransporter for targeted binding based on nucleic acid anchor system. Electrophoresis 2013; 35:393-404. [DOI: 10.1002/elps.201300197] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2013] [Revised: 06/19/2013] [Accepted: 06/19/2013] [Indexed: 01/16/2023]
Affiliation(s)
- Lukas Nejdl
- Department of Chemistry and Biochemistry; Faculty of Agronomy; Mendel University in Brno; Brno Czech Republic
| | - Miguel Angel Merlos Rodrigo
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Central European Institute of Technology; Brno University of Technology; Brno Czech Republic
| | - Jiri Kudr
- Department of Chemistry and Biochemistry; Faculty of Agronomy; Mendel University in Brno; Brno Czech Republic
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Central European Institute of Technology; Brno University of Technology; Brno Czech Republic
| | - Branislav Ruttkay-Nedecky
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Central European Institute of Technology; Brno University of Technology; Brno Czech Republic
| | - Marie Konecna
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Central European Institute of Technology; Brno University of Technology; Brno Czech Republic
| | - Pavel Kopel
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Central European Institute of Technology; Brno University of Technology; Brno Czech Republic
| | - Ondrej Zitka
- Department of Chemistry and Biochemistry; Faculty of Agronomy; Mendel University in Brno; Brno Czech Republic
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Central European Institute of Technology; Brno University of Technology; Brno Czech Republic
| | - Jaromir Hubalek
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Central European Institute of Technology; Brno University of Technology; Brno Czech Republic
| | - Rene Kizek
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Central European Institute of Technology; Brno University of Technology; Brno Czech Republic
| | - Vojtech Adam
- Department of Chemistry and Biochemistry; Faculty of Agronomy; Mendel University in Brno; Brno Czech Republic
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Central European Institute of Technology; Brno University of Technology; Brno Czech Republic
| |
Collapse
|
33
|
Mathematical modeling of interdigitated electrode arrays in finite electrochemical cells. J Electroanal Chem (Lausanne) 2013. [DOI: 10.1016/j.jelechem.2013.07.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
34
|
Wang Z, Fan Y, Chen J, Guo Y, Wu W, He Y, Xu L, Fu F. A microfluidic chip-based fluorescent biosensor for the sensitive and specific detection of label-free single-base mismatch via magnetic beads-based “sandwich” hybridization strategy. Electrophoresis 2013; 34:2177-84. [DOI: 10.1002/elps.201300131] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Revised: 04/16/2013] [Accepted: 04/17/2013] [Indexed: 01/03/2023]
Affiliation(s)
- ZongWen Wang
- Key Lab of Analysis and Detection for Food Safety of Ministry of Education; Fujian Provincial Key Lab of Analysis and Detection for Food Safety; Department of Chemistry Fuzhou University; Fuzhou; Fujian; P.R. China
| | - YingWei Fan
- Key Lab of Analysis and Detection for Food Safety of Ministry of Education; Fujian Provincial Key Lab of Analysis and Detection for Food Safety; Department of Chemistry Fuzhou University; Fuzhou; Fujian; P.R. China
| | - JinFa Chen
- Key Lab of Analysis and Detection for Food Safety of Ministry of Education; Fujian Provincial Key Lab of Analysis and Detection for Food Safety; Department of Chemistry Fuzhou University; Fuzhou; Fujian; P.R. China
| | - Ying Guo
- Key Lab of Analysis and Detection for Food Safety of Ministry of Education; Fujian Provincial Key Lab of Analysis and Detection for Food Safety; Department of Chemistry Fuzhou University; Fuzhou; Fujian; P.R. China
| | - WeiHua Wu
- Key Lab of Analysis and Detection for Food Safety of Ministry of Education; Fujian Provincial Key Lab of Analysis and Detection for Food Safety; Department of Chemistry Fuzhou University; Fuzhou; Fujian; P.R. China
| | - Ye He
- Key Lab of Analysis and Detection for Food Safety of Ministry of Education; Fujian Provincial Key Lab of Analysis and Detection for Food Safety; Department of Chemistry Fuzhou University; Fuzhou; Fujian; P.R. China
| | - LiangJun Xu
- Key Lab of Analysis and Detection for Food Safety of Ministry of Education; Fujian Provincial Key Lab of Analysis and Detection for Food Safety; Department of Chemistry Fuzhou University; Fuzhou; Fujian; P.R. China
| | - FengFu Fu
- Key Lab of Analysis and Detection for Food Safety of Ministry of Education; Fujian Provincial Key Lab of Analysis and Detection for Food Safety; Department of Chemistry Fuzhou University; Fuzhou; Fujian; P.R. China
| |
Collapse
|
35
|
Micro-spot with integrated pillars (MSIP) for detection of dengue virus NS1. Biomed Microdevices 2013; 15:959-71. [DOI: 10.1007/s10544-013-9787-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
36
|
Wongkaew N, He P, Kurth V, Surareungchai W, Baeumner AJ. Multi-channel PMMA microfluidic biosensor with integrated IDUAs for electrochemical detection. Anal Bioanal Chem 2013; 405:5965-74. [PMID: 23681202 PMCID: PMC3770862 DOI: 10.1007/s00216-013-7020-0] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2013] [Revised: 04/12/2013] [Accepted: 04/24/2013] [Indexed: 10/26/2022]
Abstract
A novel multi-channel poly(methyl methacrylate) (PMMA) microfluidic biosensor with interdigitated ultramicroelectrode arrays (IDUAs) for electrochemical detection was developed. The focus of the development was a simple fabrication procedure and the realization of a reliable large IDUA that can provide detection simultaneously to several microchannels. As proof of concept, five microchannels are positioned over a large single IDUA where the channels are parallel with the length of the electrode finger. The IDUAs were fabricated on the PMMA cover piece and bonded to a PMMA substrate containing the microfluidic channels using UV/ozone-assisted thermal bonding. Conditions of device fabrication were optimized realizing a rugged large IDUA within a bonded PMMA device. Gold adhesion to the PMMA, protective coatings, and pressure during bonding were optimized. Its electrochemical performance was studied using amperometric detection of potassium ferri and ferro hexacyanide. Cumulative signals within the same chip showed very good linearity over a range of 0-38 μM (R(2) = 0.98) and a limit of detection of 3.48 μM. The bonding of the device was optimized so that no cross talk between the channels was observed which otherwise would have resulted in unreliable electrochemical responses. The highly reproducible signals achieved were comparable to those obtained with separate single-channel devices. Subsequently, the multi-channel microfluidic chip was applied to a model bioanalytical detection strategy, i.e., the quantification of specific nucleic acid sequences using a sandwich approach. Here, probe-coated paramagnetic beads and probe-tagged liposomes entrapping ferri/ferro hexacyanide as the redox marker were used to bind to a single-stranded DNA sequence. Flow rates of the non-ionic detergent n-octyl-β-D-glucopyranoside for liposome lysis were optimized, and the detection of the target sequences was carried out coulometrically within 250 s and with a limit of detection of 12.5 μM. The robustness of the design and the reliability of the results obtained in comparison to previously published single-channel designs suggest that the multi-channel device offers an excellent opportunity for bioanalytical applications that require multianalyte detection and high-throughput assays.
Collapse
Affiliation(s)
- Nongnoot Wongkaew
- School of Bioresources and Technology, King Mongkut's University of Technology Thonburi, Bangkhuntien, Bangkok 10150,Thailand
- Department of Biological and Environmental Engineering, Cornell University, 202 Riley Robb Hall, Ithaca, NY 14853, USA
| | - Peng He
- Department of Biological and Environmental Engineering, Cornell University, 202 Riley Robb Hall, Ithaca, NY 14853, USA
| | - Vanessa Kurth
- Department of Biological and Environmental Engineering, Cornell University, 202 Riley Robb Hall, Ithaca, NY 14853, USA
| | - Werasak Surareungchai
- School of Bioresources and Technology, King Mongkut's University of Technology Thonburi, Bangkhuntien, Bangkok 10150,Thailand
| | - Antje J. Baeumner
- Department of Biological and Environmental Engineering, Cornell University, 202 Riley Robb Hall, Ithaca, NY 14853, USA
| |
Collapse
|
37
|
|
38
|
Webster TA, Goluch ED. Electrochemical detection of pyocyanin in nanochannels with integrated palladium hydride reference electrodes. LAB ON A CHIP 2012; 12:5195-5201. [PMID: 23108351 DOI: 10.1039/c2lc40650k] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Miniaturized and integrated components for electrochemical detection in micro- and nano-fluidic devices are of great interest as they directly yield an electrical signal and promise sensitive, label-free, real-time detection. One of the challenges facing electrochemical sensing is the lack of reliable reference electrode options. This paper describes the fabrication and characterization of a microscale palladium hydride reference electrode in a single microfabrication step. The reference electrode was integrated inside of a nanoscale constriction along with a gold working electrode to create a complete electrochemical sensor. After charging the palladium electrode with hydrogen, the device was used to detect pyocyanin concentrations from 1-100 μM, with a 0.597 micromolar detection limit. This is the first time that a palladium hydride reference electrode has been integrated with a microfabricated electrochemical sensor in a nanofluidic setup. The device was then used over the course of 8 days to measure pyocyanin produced by four different Pseudomonas aeruginosa strains in growth media. By utilizing square wave and differential pulse voltammetry, the redox active molecule, pyocyanin, was selectively detected in a complex solution without the use of any electrode surface modification.
Collapse
Affiliation(s)
- Thaddaeus A Webster
- Department of Chemical Engineering, Northeastern University, 120 Snell Engineering Center, 360 Huntington Avenue, Boston, MA 02115, USA
| | | |
Collapse
|
39
|
Wongkaew N, Kirschbaum SEK, Surareungchai W, Durst RA, Baeumner AJ. A Novel Three-Electrode System Fabricated on Polymethyl Methacrylate for On-Chip Electrochemical Detection. ELECTROANAL 2012. [DOI: 10.1002/elan.201200336] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
40
|
Prakash S, Pinti M, Bhushan B. Theory, fabrication and applications of microfluidic and nanofluidic biosensors. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2012; 370:2269-2303. [PMID: 22509059 DOI: 10.1098/rsta.2011.0498] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Biosensors are a broad array of devices that detect the type and amount of a biological species or biomolecule. Several different types of biosensors have been developed that rely on changes to mechanical, chemical or electrical properties of the transduction or sensing element to induce a measurable signal. Often, a biosensor will integrate several functions or unit operations such as sample extraction, manipulation and detection on a single platform. This review begins with an overview of the current state-of-the-art biosensor field. Next, the review delves into a special class of biosensors that rely on microfluidics and nanofluidics by presenting the underlying theory, fabrication and several examples and applications of microfluidic and nanofluidic sensors.
Collapse
Affiliation(s)
- Shaurya Prakash
- Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, 43210, USA.
| | | | | |
Collapse
|
41
|
Abstract
AbstractOptimal detection of pathogens by molecular methods in water samples depends on the ability to extract DNA rapidly and efficiently. In this study, an innovative method was developed using a microfluidic biochip, produced by microelectrochemical system technology, and capable of performing online cell lysis and DNA extraction during a continuous flow process. On-chip cell lysis based on chemical/physical methods was performed by employing a sufficient blend of water with the lysing buffer. The efficiency of lysis with microfluidic biochip was compared with thermal lysis in Eppendorf tubes and with two commercial DNA extraction kits: Power Water DNA isolation kit and ForensicGEM Saliva isolation kit in parallel tests. Two lysing buffers containing 1% Triton X-100 or 5% Chelex were assessed for their lysis effectiveness on a microfluidic biochip. SYBR Green real-time PCR analysis revealed that cell lysis on a microfluidic biochip using 5% Chelex buffer provided better or comparable recovery of DNA than commercial isolation kits. The system yielded better results for Gram-positive bacteria than for Gram-negative bacteria and spores of Gram-positive bacteria, within the limits of detection at 103 CFU/ml. During the continuous flow process in the system, rapid cells lysis with PCR-amplifiable genomic DNA were achieved within 20 minutes.
Collapse
|
42
|
Tabares JSF, Blas ML, Sereno LE, Silber JJ, Correa NM, Molina PG. Electrochemistry in large unilamellar vesicles. The distribution of 1-naphthol studied by square wave voltammetry. Electrochim Acta 2011. [DOI: 10.1016/j.electacta.2011.09.021] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
43
|
Connelly JT, Kondapalli S, Skoupi M, Parker JSL, Kirby BJ, Baeumner AJ. Micro-total analysis system for virus detection: microfluidic pre-concentration coupled to liposome-based detection. Anal Bioanal Chem 2011; 402:315-23. [DOI: 10.1007/s00216-011-5381-9] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2011] [Revised: 08/15/2011] [Accepted: 08/30/2011] [Indexed: 11/29/2022]
|
44
|
Teles FSRR. Biosensors and rapid diagnostic tests on the frontier between analytical and clinical chemistry for biomolecular diagnosis of dengue disease: a review. Anal Chim Acta 2011; 687:28-42. [PMID: 21241843 PMCID: PMC7094386 DOI: 10.1016/j.aca.2010.12.011] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2010] [Revised: 11/09/2010] [Accepted: 12/07/2010] [Indexed: 11/26/2022]
Abstract
The past decades have witnessed enormous technological improvements towards the development of simple, cost-effective and accurate rapid diagnostic tests for detection and identification of infectious pathogens. Among them is dengue virus, the etiologic agent of the mosquito-borne dengue disease, one of the most important emerging infectious pathologies of nowadays. Dengue fever may cause potentially deadly hemorrhagic symptoms and is endemic in the tropical and sub-tropical world, being also a serious threat to temperate countries in the developed world. Effective diagnostics for dengue should be able to discriminate among the four antigenically related dengue serotypes and fulfill the requirements for successful decentralized (point-of-care) testing in the harsh environmental conditions found in most tropical regions. The accurate identification of circulating serotypes is crucial for the successful implementation of vector control programs based on reliable epidemiological predictions. This paper briefly summarizes the limitations of the main conventional techniques for biomolecular diagnosis of dengue disease and critically reviews some of the most relevant biosensors and rapid diagnostic tests developed, implemented and reported so far for point-of-care testing of dengue infections. The invaluable contributions of microfluidics and nanotechnology encompass the whole paper, while evaluation concerns of rapid diagnostic tests and foreseen technological improvements in this field are also overviewed for the diagnosis of dengue and other infectious and tropical diseases as well.
Collapse
Key Words
- cdc, centers for disease control
- denv1–4, dengue virus serotypes (1–4)
- ssrna, single-stranded ribonucleic acid
- orf, open-reading frame
- ns1, non-structural 1
- dhf, dengue hemorrhagic fever
- dss, dengue shock syndrome
- who, world health organization
- hi, hemagglutination-inhibition
- mac-eia, monoclonal antibody capture-enzyme linked immunosorbent assay
- rt-pcr, reverse transcription-polymerase chain reaction
- 3′-nr, 3′noncoding region
- rna, ribonucleic acid
- igg, immunoglobulin g
- igm, immunoglobulin m
- dna, deoxyribonucleic acid
- qcm, quartz-crystal microbalance
- mip, molecularly imprinted polymer
- gnp, gold nanoparticle
- sam, self-assembled monolayer
- bsa, bovine serum albumin
- spr, surface plasmon resonance
- nasba, nucleic acid sequence-based amplification
- s/n, signal-to-noise ratio
- cmos, complementary metal oxide semiconductor
- fia, flow-injection analysis
- fccs, fluorescence cross-correlation spectroscopy
- fcs, fluorescence correlation spectroscopy
- eis, electrochemical impedance spectroscopy
- bst, barium strontium titanate
- fet, field-effect transistor
- pna, peptide nucleic-acid
- lod, limit of detection
- cdna, complementary dna
- tdr, special programme for research and training in tropical diseases
- undp, united nations development programme
- pdvi, pediatric dengue vaccine initiative
- stard, standards for reporting of diagnostic accuracy
- fiocruz, fundação oswaldo cruz
- dpp®, dual-path platform
- blm, bilayer lipid membrane
- qd, quantum dot
- cnt, carbon nanotube
- ms, mass spectrometry
- sars, severe acute respiratory syndrome
- biosensor
- dengue
- diagnosis
- evaluation
- rapid test
- tropical disease
Collapse
Affiliation(s)
- Fernando Sérgio Rodrigues Ribeiro Teles
- Centre for Malaria and Tropical Diseases, Instituto de Higiene e Medicina Tropical, Universidade Nova de Lisboa, Rua da Junqueira 100, 1349-008 Lisboa, Portugal.
| |
Collapse
|
45
|
Fernández-Baldo MA, Messina GA, Sanz MI, Raba J. Microfluidic immunosensor with micromagnetic beads coupled to carbon-based screen-printed electrodes (SPCEs) for determination of Botrytis cinerea in tissue of fruits. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2010; 58:11201-11206. [PMID: 20931959 DOI: 10.1021/jf1025604] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A wide range of plant species, including economically important crops such as vegetables, ornamentals, bulbs, and fundamentally fruits, can be affected by gray mold caused by the fungal pathogen Botrytis cinerea . This paper describes the development of a microfluidic immunosensor with micromagnetic beads (MMBs) coupled to carbon-based screen-printed electrodes (SPCEs) for the rapid and sensitive quantification of B. cinerea in apple (Red Delicious), table grape (pink Moscatel), and pear (William's) tissues. The detection of B. cinerea was carried out using a competitive immunoassay method based on the use of purified B. cinerea antigens immobilized on 3-aminopropyl-modified MMBs. The total assay time was 40 min, and the calculated detection limit was 0.008 μg mL(-1). Moreover, the intra- and interassay coefficients of variation were below 7%. The developed method allowed detects B. cinerea even in asymptomatic fruits and promises to be particularly useful for application in the agricultural industry.
Collapse
Affiliation(s)
- Martín A Fernández-Baldo
- INQUISAL, Departamento de Química, Universidad Nacional de San Luis, CONICET, Chacabuco 917, D5700BWS San Luis, Argentina
| | | | | | | |
Collapse
|
46
|
Laschi S, Miranda-Castro R, González-Fernández E, Palchetti I, Reymond F, Rossier JS, Marrazza G. A new gravity-driven microfluidic-based electrochemical assay coupled to magnetic beads for nucleic acid detection. Electrophoresis 2010; 31:3727-36. [DOI: 10.1002/elps.201000288] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2010] [Revised: 07/12/2010] [Accepted: 07/17/2010] [Indexed: 11/08/2022]
|
47
|
O'Connor L, Glynn B. Recent advances in the development of nucleic acid diagnostics. Expert Rev Med Devices 2010; 7:529-39. [PMID: 20583889 DOI: 10.1586/erd.10.22] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Since the early 1970s, the use of nucleic acid sequences for specific diagnostic applications has followed a somewhat linear pattern of development. Early methods for restriction enzyme digestion, as well as reverse transcription, were followed in the late 1970s by Southern, northern and dot blotting, as well as DNA sequencing. In 1985, the description of PCR and the routine laboratory manipulation of sufficient quantities of DNA for diagnostics, resulted in the exponential growth of molecular biology. Subsequently, alternative DNA and RNA amplification protocols followed. The last 10 years have seen the second explosion in molecular biology with the development of real-time quantitative PCR and oligonucleotide microarrays. This advancement continues with the development of methods for 'direct' nucleic acid target detection from samples without in vitro amplification, and enhanced transduction elements for improved sensitivity of nucleic acid detection. In this article, we will describe the current state of the art in nucleic acid diagnostics, the use of nucleic acid-based diagnostics in clinical practice and the emerging technologies in the field. Finally, we will describe future trends and expected advances in the field.
Collapse
|
48
|
Lian W, Wu D, Lim DV, Jin S. Sensitive detection of multiplex toxins using antibody microarray. Anal Biochem 2010; 401:271-9. [DOI: 10.1016/j.ab.2010.02.040] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2010] [Revised: 02/03/2010] [Accepted: 02/25/2010] [Indexed: 11/28/2022]
|
49
|
Gijs MAM, Lacharme F, Lehmann U. Microfluidic applications of magnetic particles for biological analysis and catalysis. Chem Rev 2010; 110:1518-63. [PMID: 19961177 DOI: 10.1021/cr9001929] [Citation(s) in RCA: 372] [Impact Index Per Article: 24.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Martin A M Gijs
- Laboratory of Microsystems, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne EPFL, Switzerland.
| | | | | |
Collapse
|
50
|
Malic L, Brassard D, Veres T, Tabrizian M. Integration and detection of biochemical assays in digital microfluidic LOC devices. LAB ON A CHIP 2010; 10:418-31. [PMID: 20126681 DOI: 10.1039/b917668c] [Citation(s) in RCA: 101] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
The ambition of lab-on-a-chip (LOC) systems to achieve chip-level integration of a complete analytical process capable of performing a complex set of biomedical protocols is hindered by the absence of standard fluidic components able to be assembled. As a result, most microfluidic platforms built to date are highly specialized and designed to fulfill the requirements of a single particular application within a limited set of operations. Electrowetting-on-dielectric (EWOD) digital microfluidic technology has been recently introduced as a new methodology in the quest for LOC systems. Herein, unit volume droplets are manipulated along electrode arrays, allowing a microfluidic function to be reduced to a set of basic operations. The highly reprogrammable architecture of these systems can satisfy the needs of a diverse set of biochemical assays and ensure reconfigurability, flexibility and portability between different categories of applications and requirements. While important progress was made over past years in the fabrication, miniaturization and function programming of the basic EWOD fluidic operations, the success of this technology will in great part depend on the ability of researchers to couple or integrate digital microfluidics to detection approaches that can make the system competitive for LOC applications. The detection techniques should be able to circumvent the limitations of hydrophobic surfaces and exploit the advantages of the array format, high droplet transport speeds and rapid mixing schemes. This review provides an in-depth look at recent developments for the coupling and integration of detection techniques with digital microfluidic platforms for bio-chemical applications.
Collapse
Affiliation(s)
- Lidija Malic
- Biomedical Engineering Department, McGill University, Montreal, QC H3A 2B4, Canada
| | | | | | | |
Collapse
|