1
|
Effects of acute- and long-term aerobic exercises at different intensities on bone in mice. J Bone Miner Metab 2024; 42:185-195. [PMID: 38349543 DOI: 10.1007/s00774-023-01491-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 12/04/2023] [Indexed: 04/01/2024]
Abstract
INTRODUCTION Exercise intensity determines the benefits of aerobic exercise. Our objectives were, in aerobic exercise at different intensities, to determine (1) changes in bone metabolism-related genes after acute exercise and (2) changes in bone mass, strength, remodeling, and bone formation-related proteins after long-term exercise. MATERIALS AND METHODS Total 36 male C57BL/6J mice were divided into a control group and exercise groups at 3 different intensities: low, moderate, or high group. Each exercise group was assigned to acute- or long-term exercise groups. Tibias after acute exercise were evaluated by real-time PCR analysis. Furthermore, hindlimbs of long-term exercise were assessed by micro-CT, biomechanical, histological, and immunohistochemical analyses. RESULTS Acute moderate-intensity exercise decreased RANKL level as bone resorption marker, whereas low- and high-intensity exercise did not alter it. Additionally, only long-term exercise at moderate intensity increased bone mass and strength. Moderate-intensity exercise promoted osteoblast activity and suppressed osteoclast activity. After low- and high-intensity exercise, osteoblast and osteoclast activity were unchanged. An increase in the number of β-catenin-positive cells and a decrease in sclerostin-positive cells were observed in the only moderate group. CONCLUSION These results showed that moderate-intensity exercise can inhibit bone resorption earlier, and long-term exercise can increase bone mass and strength through promoted bone formation via the Wnt/β-catenin activation. High-intensity exercise, traditionally considered better for bone, may fail to stimulate bone remodeling, leading to no change in bone mass and strength. Our findings suggest that moderate-intensity exercise, neither too low nor high, can maintain bone health.
Collapse
|
2
|
PDMS-embedded wearable FBG sensors for gesture recognition and communication assistance. BIOMEDICAL OPTICS EXPRESS 2024; 15:1892-1909. [PMID: 38495686 PMCID: PMC10942691 DOI: 10.1364/boe.517104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 01/31/2024] [Accepted: 01/31/2024] [Indexed: 03/19/2024]
Abstract
This study introduces fiber Bragg grating (FBG) sensors embedded in polydimethylsiloxane (PDMS) silicone elastomer specifically engineered for recognizing intricate gestures like wrist pitch, finger bending, and mouth movement. Sensors with different PDMS patch thicknesses underwent evaluation including thermal, tensile strain, and bending deformation characterization, demonstrating a stability of at least four months. Experiments revealed the FBG sensors' accurate wrist pitch recognition across participants after calibration, confirmed by statistical metrics and Bland-Altman plots. Utilizing finger and mouth movements, the developed system shows promise in assisting post-stroke patients and individuals with disabilities, enhancing their interaction capabilities with the external surroundings.
Collapse
|
3
|
Digital image correlation in dental materials and related research: A review. Dent Mater 2021; 37:758-771. [PMID: 33715864 DOI: 10.1016/j.dental.2021.02.024] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 02/23/2021] [Accepted: 02/24/2021] [Indexed: 12/16/2022]
Abstract
OBJECTIVE Digital image correlation (DIC) is a non-contact image processing technique for full-field strain measurement. Although DIC has been widely used in engineering and biomechanical fields, it is in the spotlight only recently in dental materials. Therefore, the purpose of this review paper is introducing the working principle of the DIC technique with some modifications and providing further potential applications in various dental materials and related fields. METHODS The accuracy of the algorithm depending on the environmental characteristics of the DIC technique, as well as the advantages and disadvantages of strain measurement using optical measurements, have been elaborated in dental materials and related fields. Applications to those researches have been classified into the following categories: shrinkage behavior of light-cured resin composite, resin-tooth interface, mechanical properties of tooth structure, crack extension and elastic properties of dental materials, and deformation of dental restoration and prosthesis. This classification and discussion were performed using literature survey and review based on numerous papers in the international journals published over the past 20 years. The future directions for predicting the precise deformation of dental materials under various environments, as well as limitations of the DIC technique, was presented in this review. RESULTS The DIC technique was demonstrated as a more effective tool to measure full-field polymerization shrinkage of composite resin, even in a simulated clinical condition over the existing methods. Moreover, the DIC combined with other technologies can be useful to evaluate the mechanical behavior of material-tooth interface, dentine structure and restorative and prosthetic materials with high accuracy. Three-dimensional DIC using two cameras extended the measurement range in-plane to out-of-plane, enabling measure of the strain directly on the surface of dental restorations or prosthesis. SIGNIFICANCE DIC technique is a potential tool for measuring and predicting the full-field deformation/strain of dental materials and actual prostheses in diverse clinical conditions. The versatility of DIC can replace the existing complex sensor devices in those studies.
Collapse
|
4
|
Fiber Optic Sensors for Vital Signs Monitoring. A Review of Its Practicality in the Health Field. BIOSENSORS 2021; 11:58. [PMID: 33672317 PMCID: PMC7926559 DOI: 10.3390/bios11020058] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 02/18/2021] [Accepted: 02/19/2021] [Indexed: 02/07/2023]
Abstract
Vital signs not only reflect essential functions of the human body but also symptoms of a more serious problem within the anatomy; they are well used for physical monitoring, caloric expenditure, and performance before a possible symptom of a massive failure-a great variety of possibilities that together form a first line of basic diagnosis and follow-up on the health and general condition of a person. This review includes a brief theory about fiber optic sensors' operation and summarizes many research works carried out with them in which their operation and effectiveness are promoted to register some vital sign(s) as a possibility for their use in the medical, health care, and life support fields. The review presents methods and techniques to improve sensitivity in monitoring vital signs, such as the use of doping agents or coatings for optical fiber (OF) that provide stability and resistance to the external factors from which they must be protected in in vivo situations. It has been observed that most of these sensors work with single-mode optical fibers (SMF) in a spectral range of 1550 nm, while only some work in the visible spectrum (Vis); the vast majority, operate through fiber Bragg gratings (FBG), long-period fiber gratings (LPFG), and interferometers. These sensors have brought great advances to the measurement of vital signs, especially with regard to respiratory rate; however, many express the possibility of monitoring other vital signs through mathematical calculations, algorithms, or auxiliary devices. Their advantages due to miniaturization, immunity to electromagnetic interference, and the absence of a power source makes them truly desirable for everyday use at all times.
Collapse
|
5
|
In Vivo Deformation and Strain Measurements in Human Bone Using Digital Volume Correlation (DVC) and 3T Clinical MRI. MATERIALS 2020; 13:ma13235354. [PMID: 33255848 PMCID: PMC7728341 DOI: 10.3390/ma13235354] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 11/20/2020] [Accepted: 11/23/2020] [Indexed: 12/15/2022]
Abstract
Strains within bone play an important role in the remodelling process and the mechanisms of fracture. The ability to assess these strains in vivo can provide clinically relevant information regarding bone health, injury risk, and can also be used to optimise treatments. In vivo bone strains have been investigated using multiple experimental techniques, but none have quantified 3D strains using non-invasive techniques. Digital volume correlation based on clinical MRI (DVC-MRI) is a non-invasive technique that has the potential to achieve this. However, before it can be implemented, uncertainties associated with the measurements must be quantified. Here, DVC-MRI was evaluated to assess its potential to measure in vivo strains in the talus. A zero-strain test (two repeated unloaded scans) was conducted using three MRI sequences, and three DVC approaches to quantify errors and to establish optimal settings. With optimal settings, strains could be measured with a precision of 200 με and accuracy of 480 με for a spatial resolution of 7.5 mm, and a precision of 133 με and accuracy of 251 με for a spatial resolution of 10 mm. These results demonstrate that this technique has the potential to measure relevant levels of in vivo bone strain and to be used for a range of clinical applications.
Collapse
|
6
|
Measuring the Internal Stress in Ovine Meniscus During Simulated In Vivo Gait Kinematics: A Novel Method Using Fibre Optic Technology. Ann Biomed Eng 2020; 49:1199-1208. [PMID: 33094418 DOI: 10.1007/s10439-020-02652-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Accepted: 10/05/2020] [Indexed: 11/29/2022]
Abstract
Changes in stress transferred across articular joints have been described as a substantial factor in the initiation and progression of joint disease such as post-traumatic osteoarthritis and have thus been of interest to biomechanical researchers. However, to date, stress magnitudes within the menisci have not been successfully measured. In this study, a novel method for measuring stress within the menisci is presented. Small Fibre Bragg Grating (FBG) sensors were inserted inside menisci and used to measure mechanical stress during replicated gait cycles. In-vitro stress measurements within the menisci were preformed for healthy gait and gait following surgical damage to the joints. Together with our capability to reproduce in vivo motions accurately, the improvements in fibre optic technology have allowed for the first direct measurement of mechanical stress in menisci.
Collapse
|
7
|
Application of Fibre Bragg Grating Sensors in Strain Monitoring and Fracture Recovery of Human Femur Bone. Bioengineering (Basel) 2020; 7:bioengineering7030098. [PMID: 32825200 PMCID: PMC7552668 DOI: 10.3390/bioengineering7030098] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 08/03/2020] [Accepted: 08/17/2020] [Indexed: 11/17/2022] Open
Abstract
Fibre Bragg Grating (FBG) sensors are gaining popularity in biomedical engineering. However, specific standards for in vivo testing for their use are absolutely limited. In this study, in vitro experimental tests were performed to investigate the behaviors and applications of gratings attached to intact and fractured thighbone for a range of compression loading (<300 N) based around some usual daily activities. The wavelength shifts and the corresponding strain sensitivities of the FBG sensors were measured to determine their effectiveness in monitoring the femoral fracture healing process. Four different arrangements of FBG sensors were selected to measure strains at different critical locations on the femoral sawbones surface. Data obtained for intact and plated sawbones were compared using both embedded longitudinal and coiled FBG arrays. Strains were measured close to the fracture, posterior linea aspera and popliteal surface areas, as well as at the proximal and distal ends of the synthetic femur; their responses are discussed herein. The gratings on the longitudinally secured FBG arrays were found to provide high levels of sensitivity and precise measurements, even for relatively small loads (<100 N). Nevertheless, embedding angled FBG sensors is essential to measure the strain generated by applied torque on the femur bone. The maximum recorded strain of the plated femur was 503.97 µε for longitudinal and -274.97 µε for coiled FBG arrays, respectively. These project results are important to configure effective arrangements and orientations of FBG sensors with respect to fracture position and fixation implant for future in vivo experiments.
Collapse
|
8
|
Stress Measurements on the Articular Cartilage Surface Using Fiber Optic Technology and In-Vivo Gait Kinematics. Ann Biomed Eng 2020; 48:2836-2845. [PMID: 32342234 DOI: 10.1007/s10439-020-02516-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Accepted: 04/15/2020] [Indexed: 10/24/2022]
Abstract
It has been hypothesized a change in stress on the cartilage of a joint is a significant factor in the initiation and progression of post-traumatic osteoarthritis. Without a reliable method for measuring stress, this hypothesis has largely gone untested. In this study, a novel, repeatable, and reliable method for measuring stress on the surface of articular cartilage in articular joints is presented. Small Fiber Bragg Grating (FBG) sensors capable of measuring normal stress between contact surfaces in diarthrodial joints were developed and validated. The small size of these sensors (diameter of 125-300 μm and sensing length of 1 mm) allows them to be inserted into the joint space without the removal of biomechanically relevant structures. In-vitro stresses on the surface of the cartilage for both healthy and surgically damaged joints were measured after implantation of the FBG sensors using in vivo generated gait kinematic data and a 6-degrees of freedom parallel robot. Along with our capability to reproduce in vivo motions accurately and the improvements in fiber optic technology, this study describes the first direct measurement of stress in a joint using in vivo gait kinematics.
Collapse
|
9
|
Abstract
A luminescent spectral ruler was developed to measure micrometer to millimeter displacements through tissue. The spectral ruler has two components: a luminescent encoder patterned with alternating stripes of two spectrally distinct luminescent materials and an analyzer mask with periodic transparent windows the same width as the encoder stripes. The analyzer mask is placed over the encoder and held so that only one type of luminescent stripe is visible through the window; sliding the analyzer over the encoder modulates the luminescence spectrum acquired through the analyzer windows, enabling detection of small displacements without imaging. We prepared two types of spectral rulers, one with a fluorescent encoder and a second with an X-ray excited optical luminescent (XEOL) encoder. The fluorescent ruler used two types of quantum dots to form stripes that were excited with 633 nm light and emitted at 645 and 680 nm, respectively. Each ruler type was covered with chicken breast tissue to simulate implantation. The XEOL ruler generated a strong signal with negligible tissue autofluorescence but used ionizing radiation, while the fluorescence ruler used non-ionizing red light excitation but required spectral fitting to account for tissue autofluorescence. The precision for both types of luminescent spectral rulers (with 1 mm wide analyzer windows, and measured through 6 mm of tissue) was <2 μm, mostly limited by shot noise. The approach enabled high micrometer to millimeter displacement measurements through tissue and has applications in biomechanical and mechanochemical measurements (e.g., tracking postsurgical bone healing and implant-associated infection).
Collapse
|
10
|
Smart orthopaedic implants: A targeted approach for continuous postoperative evaluation in the spine. J Biomech 2020; 104:109690. [PMID: 32139096 DOI: 10.1016/j.jbiomech.2020.109690] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 02/17/2020] [Accepted: 02/23/2020] [Indexed: 11/16/2022]
Abstract
Real-time health monitoring systems are emerging in diverse medical fields, tracking biological and physiological signals for direct feedback to the user. Orthopaedics is yet to adapt to innovative trends in health monitoring. Despite an evident entry point during orthopaedic surgeries, clinicians remain unable to objectively examine the structural integrity and biomechanics in the operated region through implantable sensors. As such, postoperative advice can be non-specific and poorly guided. This perspective discusses the clinical need for load-sensing implants that address biomechanical postoperative monitoring, taking the example of spinal interbody cages. Research has attempted to establish sensing approaches in different orthopaedic settings; however, they fail to meet mechanical sensing requirements or lack in vivo translatability, especially in the spine. Polymeric flexible sensors and Microelectromechanical Systems (MEMS) have favourable attributes aligned to the required features for in vivo load-sensing, although these approaches are yet to be tested extensively in orthopaedics. While inductive powering is promising, wireless energy transfer and telemetry are areas of ongoing research. This perspective proposes a thorough understanding of the relevant biomechanics to identify the pertinent sensing parameters, concurrent treatment of sensing and powering aspects, and utilisation of energy harvesting for sensing and data transmission. While sensing advancements have contributed to the rise of real-time health monitoring in other fields of medicine, orthopaedics has so far been overlooked. It is the application of these innovations that will lead to the development of a new generation of 'smart' implants for continuous postoperative evaluation.
Collapse
|
11
|
Sensing and actuation technologies for smart socket prostheses. Biomed Eng Lett 2019; 10:103-118. [PMID: 32175132 DOI: 10.1007/s13534-019-00137-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 10/17/2019] [Accepted: 10/26/2019] [Indexed: 01/20/2023] Open
Abstract
The socket is the most critical part of every lower-limb prosthetic system, since it serves as the interfacial component that connects the residual limb with the artificial system. However, many amputees abandon their socket prostheses due to the high-level of discomfort caused by the poor interaction between the socket and residual limb. In general, socket prosthesis performance is determined by three main factors, namely, residual limb-socket interfacial stress, volume fluctuation of the residual limb, and temperature. This review paper summarizes the various sensing and actuation solutions that have been proposed for improving socket performance and for realizing next-generation socket prostheses. The working principles of different sensors and how they have been tested or used for monitoring the socket interface are discussed. Furthermore, various actuation methods that have been proposed for actively modifying and improving the socket interface are also reviewed. Through the continued development and integration of these sensing and actuation technologies, the long-term vision is to realize smart socket prostheses. Such smart socket systems will not only function as a socket prosthesis but will also be able to sense parameters that cause amputee discomfort and self-adjust to optimize its fit, function, and performance.
Collapse
|
12
|
Quantitative method for gait pattern detection based on fiber Bragg grating sensors. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:37005. [PMID: 28353688 DOI: 10.1117/1.jbo.22.3.037005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2016] [Accepted: 03/14/2017] [Indexed: 06/06/2023]
Abstract
This paper presents a method that uses fiber Bragg grating (FBG) sensors to distinguish the temporal gait patterns in gait cycles. Unlike most conventional methods that focus on electronic sensors to collect those physical quantities (i.e., strains, forces, pressure, displacements, velocity, and accelerations), the proposed method utilizes the backreflected peak wavelength from FBG sensors to describe the motion characteristics in human walking. Specifically, the FBG sensors are sensitive to external strain with the result that their backreflected peak wavelength will be shifted according to the extent of the influence of external strain. Therefore, when subjects walk in different gait patterns, the strains on FBG sensors will be different such that the magnitude of the backreflected peak wavelength varies. To test the reliability of the FBG sensor platform for gait pattern detection, the gold standard method using force-sensitive resistors (FSRs) for defining gait patterns is introduced as a reference platform. The reliability of the FBG sensor platform is determined by comparing the detection results between the FBG sensors and FSRs platforms. The experimental results show that the FBG sensor platform is reliable in gait pattern detection and gains high reliability when compared with the reference platform.
Collapse
|
13
|
Highly Stretchable, Strain Sensing Hydrogel Optical Fibers. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2016; 28:10244-10249. [PMID: 27714887 PMCID: PMC5148684 DOI: 10.1002/adma.201603160] [Citation(s) in RCA: 91] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2016] [Revised: 08/14/2016] [Indexed: 05/17/2023]
Abstract
A core-clad fiber made of elastic, tough hydrogels is highly stretchable while guiding light. Fluorescent dyes are easily doped into the hydrogel fiber by diffusion. When stretched, the transmission spectrum of the fiber is altered, enabling the strain to be measured and also its location.
Collapse
|
14
|
Abstract
Osteoporosis is still a serious issue in healthcare, and will continue to increase due to the aging and growth of the population. Early diagnosis is the key to successfully treating many diseases. The earlier the osteoporosis is diagnosed, the more quickly people can take action to stop bone deterioration. Motivated by this, researchers and companies have begun developing smart in situ bone sensors in order to dramatically help people to monitor their bone mass density (BMD), bone strain or bone turnover markers (BTMs); promptly track early signs of osteoporosis; and even monitor the healing process following surgery or antiresorptive therapy. This paper focuses on the latest advancements in the field of bone biosensing materials and sensor technologies and how they can help now and in the future to detect disease and monitor bone health.
Collapse
|
15
|
Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research. SENSORS 2016; 16:s16071119. [PMID: 27447646 PMCID: PMC4970162 DOI: 10.3390/s16071119] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Revised: 05/12/2016] [Accepted: 06/02/2016] [Indexed: 11/18/2022]
Abstract
The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket.
Collapse
|
16
|
Mechanical testing and modelling of the Universal 2 implant. Med Eng Phys 2016; 38:511-7. [PMID: 27083120 DOI: 10.1016/j.medengphy.2016.02.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Revised: 01/18/2016] [Accepted: 02/05/2016] [Indexed: 11/29/2022]
Abstract
Understanding the load mechanics of orthopaedic implants is important to be able to predict their behaviour in-vivo. Much research, both mechanical and clinical, has been carried out on hip and knee implants, but less has been written about the mechanics of wrist implants. In this paper, the load mechanics of the Universal 2 wrist implant have been measured using two types of measuring techniques, strain gauges and Fibre Bragg Grating measurements to measure strains. The results were compared to a finite element model of the implant. The results showed that the computational results were in good agreement with the experimental results. Better understanding of the load mechanics of wrist implants, using models and experimental results can catalyse the development of future generation implants.
Collapse
|
17
|
Extracting accurate strain measurements in bone mechanics: A critical review of current methods. J Mech Behav Biomed Mater 2015; 50:43-54. [DOI: 10.1016/j.jmbbm.2015.06.006] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2015] [Revised: 06/01/2015] [Accepted: 06/02/2015] [Indexed: 11/19/2022]
|
18
|
|
19
|
Evaluation of a dentoalveolar model for testing mouthguards: stress and strain analyses. Dent Traumatol 2015; 32:4-13. [DOI: 10.1111/edt.12197] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/30/2015] [Indexed: 11/30/2022]
|
20
|
Body-monitoring and health supervision by means of optical fiber-based sensing systems in medical textiles. Adv Healthc Mater 2015; 4:330-55. [PMID: 25358557 DOI: 10.1002/adhm.201400463] [Citation(s) in RCA: 90] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Revised: 09/24/2014] [Indexed: 11/11/2022]
Abstract
Long-term monitoring with optical fibers has moved into the focus of attention due to the applicability for medical measurements. Within this Review, setups of flexible, unobtrusive body-monitoring systems based on optical fibers and the respective measured vital parameters are in focus. Optical principles are discussed as well as the interaction of light with tissue. Optical fiber-based sensors that are already used in first trials are primarily selected for the section on possible applications. These medical textiles include the supervision of respiration, cardiac output, blood pressure, blood flow and its saturation with hemoglobin as well as oxygen, pressure, shear stress, mobility, gait, temperature, and electrolyte balance. The implementation of these sensor concepts prompts the development of wearable smart textiles. Thus, current sensing techniques and possibilities within photonic textiles are reviewed leading to multiparameter designs. Evaluation of these designs should show the great potential of optical fibers for the introduction into textiles especially due to the benefit of immunity to electromagnetic radiation. Still, further improvement of the signal-to-noise ratio is often necessary to develop a commercial monitoring system.
Collapse
|
21
|
Effect of elbow flexion angles on stress distribution of the proximal ulnar and radius bones under a vertical load: measurement using resistance strain gauges. J Orthop Surg Res 2014; 9:60. [PMID: 25078971 PMCID: PMC4131162 DOI: 10.1186/s13018-014-0060-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2014] [Accepted: 07/01/2014] [Indexed: 11/12/2022] Open
Abstract
Objectives This study aimed to explore the surface stress at the proximal ends of the ulna and radius at different elbow flexion angles using the resistance strain method. Methods Eight fresh adult cadaveric elbows were tested. The forearms were fixed in a neutral position. Axial load increment experiments were conducted at four different elbow flexion angles (0°, 15°, 30°, and 45°). Surface stain was measured at six sites (tip, middle, and base of the coronoid process; back ulnar notch; olecranon; and anterolateral margin of the radial head). Results With the exception of the ulnar olecranon, the load-stress curves at each measurement site showed an approximately linear relationship under the four working conditions studied. At a vertical load of 500 N, the greatest stress occurred at the middle of the coronoid process when the elbow flexion angles were 0° and 15°. When the flexion angles were 30° and 45°, the greatest stress occurred at the base of the coronoid process. The stress on the radial head was higher than those at the measurement sites of the proximal end of the ulna. Conclusion The resistance strain method for measuring elbow joint surface stress benefits biomechanics research on the elbow joint. Elbow joint surface stress distributions vary according to different elbow flexion angles.
Collapse
|
22
|
From conventional sensors to fibre optic sensors for strain and force measurements in biomechanics applications: a review. J Biomech 2014; 47:1251-61. [PMID: 24612722 DOI: 10.1016/j.jbiomech.2014.01.054] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Revised: 01/07/2014] [Accepted: 01/25/2014] [Indexed: 11/23/2022]
Abstract
In vivo measurement, not only in animals but also in humans, is a demanding task and is the ultimate goal in experimental biomechanics. For that purpose, measurements in vivo must be performed, under physiological conditions, to obtain a database and contribute for the development of analytical models, used to describe human biomechanics. The knowledge and control of the mechanisms involved in biomechanics will allow the optimization of the performance in different topics like in clinical procedures and rehabilitation, medical devices and sports, among others. Strain gages were first applied to bone in a live animal in 40's and in 80's for the first time were applied fibre optic sensors to perform in vivo measurements of Achilles tendon forces in man. Fibre optic sensors proven to have advantages compare to conventional sensors and a great potential for biomechanical and biomedical applications. Compared to them, they are smaller, easier to implement, minimally invasive, with lower risk of infection, highly accurate, well correlated, inexpensive and multiplexable. The aim of this review article is to give an overview about the evolution of the experimental techniques applied in biomechanics, from conventional to fibre optic sensors. In the next sections the most relevant contributions of these sensors, for strain and force in biomechanical applications, will be presented. Emphasis was given to report of in vivo experiments and clinical applications.
Collapse
|
23
|
A new approach to ballistocardiographic measurements using fibre Bragg grating-based sensors. Biocybern Biomed Eng 2014. [DOI: 10.1016/j.bbe.2014.02.001] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
24
|
The use of fiber Bragg grating sensors in biomechanics and rehabilitation applications: the state-of-the-art and ongoing research topics. SENSORS (BASEL, SWITZERLAND) 2012; 12:12890-926. [PMID: 23201977 PMCID: PMC3545548 DOI: 10.3390/s121012890] [Citation(s) in RCA: 102] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2012] [Revised: 08/14/2012] [Accepted: 08/22/2012] [Indexed: 01/26/2023]
Abstract
In recent years, fiber Bragg gratings (FBGs) are becoming increasingly attractive for sensing applications in biomechanics and rehabilitation engineering due to their advantageous properties like small size, light weight, biocompatibility, chemical inertness, multiplexing capability and immunity to electromagnetic interference (EMI). They also offer a high-performance alternative to conventional technologies, either for measuring a variety of physical parameters or for performing high-sensitivity biochemical analysis. FBG-based sensors demonstrated their feasibility for specific sensing applications in aeronautic, automotive, civil engineering structure monitoring and undersea oil exploration; however, their use in the field of biomechanics and rehabilitation applications is very recent and its practicality for full-scale implementation has not yet been fully established. They could be used for detecting strain in bones, pressure mapping in orthopaedic joints, stresses in intervertebral discs, chest wall deformation, pressure distribution in Human Machine Interfaces (HMIs), forces induced by tendons and ligaments, angles between body segments during gait, and many others in dental biomechanics. This article aims to provide a comprehensive overview of all the possible applications of FBG sensing technology in biomechanics and rehabilitation and the status of ongoing researches up-to-date all over the world, demonstrating the FBG advances over other existing technologies.
Collapse
|
25
|
Differences in external and internal cortical strain with prosthesis in the femur. Open Orthop J 2012; 5:379-84. [PMID: 22235237 PMCID: PMC3253998 DOI: 10.2174/1874325001105010379] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2011] [Revised: 09/01/2011] [Accepted: 09/05/2011] [Indexed: 11/25/2022] Open
Abstract
The contact between a femoral stem prosthesis and the internal surface of the cortical bone with the stress in the interface is of crucial importance with respect to loosening. However, there are no reports of strain patterns at this site, and the main aim of the current study was to investigate differences of internal and external cortical strain in the proximal femur after insertion of a stem prosthesis. The external cortical strain of a human cadaveric femur was measured with strain gauges before and after implantation of a stem prosthesis. By use of optical fibres embedded longitudinally in the endosteal cortex, deformations at the implant–internal cortex interface could also be measured. The main external deformation during loading of the intact femur occurred as compression of the medial cortex; both at the proximal and distal levels. The direction of the principal strain on the medial and lateral aspects was close to the longitudinal axis of the bone. After resection of the femoral neck and insertion of a stem prosthesis, the changes in external strain values were greatest medially at the proximal level, where the magnitude of deformation in compression was reduced to about half the values measured on the intact specimen. Otherwise, there were rather small changes in external principal strain. However, by comparing vertical strain in the external and internal cortex of the proximal femur, there were great differences in values and patterns at all positions. The transcortical differences in strain varied from compression on one side to distraction on the other and vice versa in some of the positions with a correlation coefficient of 0.07. Our results show that differences exist between the external and internal cortical strain when loading a stem prosthesis. Hence, strain at the internal cortex does not correspond and can not be deducted from measured strain at the external cortex.
Collapse
|
26
|
Abstract
BACKGROUND There is no standard technique to monitor impact absorption capability of mouthguards. Earlier investigations have established that strain transferred to the teeth through mouthguard is a good indication of their efficiency. In the present study, a unique experimental scheme utilizing fiber Bragg gratings (FBGs) as distributed strain sensors is proposed and investigated to estimate impact absorption capability of custom-made mouthguard. The proposed methodology is useful due to advantages such as, very small size and flexibility for ease of bonding, self-referencing, and multiplexing capability of using FBG sensors. MATERIAL AND METHODS Finite-element analysis was performed to simulate the stress distribution due to impact on the mouthguard. The FBGs were fabricated by exposing the core of photosensitive fiber to intense Ultra-Violet light through a 'phase mask'. One FBG sensor was bonded on the jaw model and another on the mouthguard surface at similar positions, so that both gratings are simultaneously affected by impact. Two different sets of the sensors were used, one for the anterior region and another for posterior region. The impact was produced using customized pendulum device with interchangeable impact objects i.e. cricket ball, hockey ball, and steel ball. Response of gratings was monitored using optical spectrum analyzer and strain induced due to each impact was determined from the Bragg wavelength shifts for each grating. RESULTS AND CONCLUSIONS Strain induced due to impact was calculated from the Bragg wavelength shifts. Difference in the strain values for the two gratings is interpreted as impact energy absorbed by the mouthguard. The Bragg wavelength shifts (induced strain) for FBG bonded on the jaw model was much lower than the shift for FBG bonded on the mouthguard, indicating that most of the impact energy is absorbed by the mouthguard.
Collapse
|
27
|
In the trail of a new bio-sensor for measuring strain in bone: Osteoblastic biocompatibility. Biosens Bioelectron 2011; 26:4046-52. [DOI: 10.1016/j.bios.2011.03.028] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2011] [Revised: 03/16/2011] [Accepted: 03/27/2011] [Indexed: 10/18/2022]
|
28
|
Copolymers of a new methacrylate monomer bearing oxime ester and ether with methyl methacrylate: Synthesis, characterization, monomer reactivity ratios, and biological activity. J Appl Polym Sci 2010. [DOI: 10.1002/app.33090] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
29
|
Fiber Bragg grating sensor for monitoring bone decalcification. Orthop Traumatol Surg Res 2010; 96:646-51. [PMID: 20801730 DOI: 10.1016/j.otsr.2010.04.010] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2009] [Revised: 12/24/2009] [Accepted: 04/19/2010] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Estimation of decalcification is a vital tool to discern bone health. Different techniques are used for its quantitative measurement, e.g. DEXA, QCT & QUS. All these techniques, although noninvasive, suffer from limitations such as radiation exposure and inaccurate values. Recently, fiber optic techniques are fast emerging for medical applications owing to their various attractive features like immunity to EMI/RFI, geometric versatility, chemical inertness, etc. MATERIAL AND METHODS The effect of decalcification on strain response of a goat tibia was investigated in vitro using fiber Bragg grating (FBG) sensing technique. The bone was strained by using three-point bending technique and corresponding Bragg wavelength shifts were recorded. Two similar bone samples from the same animal were taken and one was partially decalcified. Strain response of decalcified and untreated bone was taken concurrently to monitor the effects of calcium loss and that of degradation with time. RESULTS AND CONCLUSION The strain generated for same stress increased with greater degree of decalcification and a steep increase occurred after 2g calcium loss, indicating the onset of damage. The strain response, therefore gives a direct indication of the degree of calcium present in the bone. LEVEL OF EVIDENCE Level III.
Collapse
|
30
|
Synthesis and characterization of novel methacrylate copolymers based on sulfonamide and coumarine: Monomer reactivity ratios, biological activity, thermal stability, and optical properties. ACTA ACUST UNITED AC 2010. [DOI: 10.1002/pola.24220] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|