1
|
Yu X, Ding J, He Y, Wei S, Chen X, Luo Q, Zhang Y, Qian C, Wang J, Hu M, Zhang X, Lu C, Liu J, Zhou J. Porcine pericardium crosslinked with POSS-PEG-CHO possesses weakened immunogenicity and anti-calcification property. Mater Today Bio 2025; 32:101677. [PMID: 40242484 PMCID: PMC12002838 DOI: 10.1016/j.mtbio.2025.101677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2024] [Revised: 02/19/2025] [Accepted: 03/16/2025] [Indexed: 04/18/2025] Open
Abstract
Valvular heart disease (VHD) poses a thorny problem in cardiovascular diseases. The most effective treatment for VHD is heart valve replacement. Biological heart valve (BHV) is more favored than mechanical heart valve due to the maturity of transcatheter heart valve replacement (THVR) and the absence of the need for lifelong anticoagulant use. However, traditional commercial BHV suffers degeneration within 10-15 years because of calcification caused by the cross-linking reagent, glutaraldehyde. Considering the remarkable properties of POSS, PEG, and the star-like eight-arm structure, we fabricated POSS-PEG-PP, which is a decellularized porcine pericardium (DPP) crosslinked by a star-like eight-arm cross-linker octafunctionalized POSS of benzaldehyde-terminated polyethylene glycol (POSS-PEG-CHO) based on the Schiff's base reaction. POSS-PEG-PP exhibits more intense fiber arrangement and better mechanical properties than GLUT-PP (glutaraldehyde crosslinked DPP). The results also show that the cytocompatibility, endothelialization, and hemocompatibility of POSS-PEG-PP are outstanding in vitro. Subsequently, in vivo assessments demonstrate that POSS-PEG-PP has anti-inflammatory and anti-calcification abilities. Furthermore, RNA sequencing analysis of subcutaneous implants suggests that the intervention of AMPK and IL-17 signaling pathways plays an important role in the inflammatory and immune responses regulation of POSS-PEG-PP. Therefore, POSS-PEG-PP is an excellent substitute material for BHVs and is expected to be clinically transformed.
Collapse
Affiliation(s)
- Xiaobo Yu
- Department of Cardiovascular Surgery, Zhongnan Hospital, Wuhan University, Wuhan, Hubei Province, 430071, China
- Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan, Hubei Province, 430071, China
- Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, Wuhan, Hubei Province, 430071, China
| | - Jingli Ding
- Department of Gastroenterology, Zhongnan Hospital of Wuhan University, Wuhan, Hubei Province, 430071, China
| | - Yingjie He
- Hubei Key Laboratory for Precision Synthesis of Small Molecule Pharmaceuticals & Ministry-of-Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Wuhan, Hubei Province, 430062, China
| | - Shunbo Wei
- Department of Cardiovascular Surgery, Zhongnan Hospital, Wuhan University, Wuhan, Hubei Province, 430071, China
- Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan, Hubei Province, 430071, China
- Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, Wuhan, Hubei Province, 430071, China
| | - Xing Chen
- Department of Cardiovascular Surgery, Zhongnan Hospital, Wuhan University, Wuhan, Hubei Province, 430071, China
- Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan, Hubei Province, 430071, China
- Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, Wuhan, Hubei Province, 430071, China
| | - Qiujie Luo
- Department of Cardiovascular Surgery, Zhongnan Hospital, Wuhan University, Wuhan, Hubei Province, 430071, China
- Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan, Hubei Province, 430071, China
- Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, Wuhan, Hubei Province, 430071, China
| | - Yuqing Zhang
- Department of Cardiovascular Surgery, Zhongnan Hospital, Wuhan University, Wuhan, Hubei Province, 430071, China
- Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan, Hubei Province, 430071, China
- Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, Wuhan, Hubei Province, 430071, China
| | - Chen Qian
- Department of Cardiovascular Surgery, Zhongnan Hospital, Wuhan University, Wuhan, Hubei Province, 430071, China
- Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan, Hubei Province, 430071, China
- Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, Wuhan, Hubei Province, 430071, China
| | - Jiahui Wang
- Department of Cardiovascular Surgery, Zhongnan Hospital, Wuhan University, Wuhan, Hubei Province, 430071, China
- Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan, Hubei Province, 430071, China
- Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, Wuhan, Hubei Province, 430071, China
| | - Mengjie Hu
- Department of Cardiovascular Surgery, Zhongnan Hospital, Wuhan University, Wuhan, Hubei Province, 430071, China
- Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan, Hubei Province, 430071, China
- Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, Wuhan, Hubei Province, 430071, China
| | - Xiang Zhang
- Department of Cardiovascular Surgery, Zhongnan Hospital, Wuhan University, Wuhan, Hubei Province, 430071, China
- Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan, Hubei Province, 430071, China
- Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, Wuhan, Hubei Province, 430071, China
| | - Cuifen Lu
- Hubei Key Laboratory for Precision Synthesis of Small Molecule Pharmaceuticals & Ministry-of-Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Wuhan, Hubei Province, 430062, China
| | - Jinping Liu
- Department of Cardiovascular Surgery, Zhongnan Hospital, Wuhan University, Wuhan, Hubei Province, 430071, China
- Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan, Hubei Province, 430071, China
- Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, Wuhan, Hubei Province, 430071, China
| | - Jianliang Zhou
- Department of Cardiovascular Surgery, Zhongnan Hospital, Wuhan University, Wuhan, Hubei Province, 430071, China
- Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan, Hubei Province, 430071, China
- Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, Wuhan, Hubei Province, 430071, China
| |
Collapse
|
2
|
Matijosius T, Bakute N, Padgurskas J, Selskiene A, Zarkov A, Griguceviciene A, Kavaliauskaite J, Stirke A, Asadauskas SJ. Corrosion and Biocompatibility Studies of Bioceramic Alumina Coatings on Aluminum Alloy 6082. ACS APPLIED MATERIALS & INTERFACES 2025; 17:24901-24917. [PMID: 40249635 DOI: 10.1021/acsami.5c00532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/19/2025]
Abstract
Recent advances in ceramic materials, particularly porous alumina (Al2O3), have significantly enhanced the safety and efficacy of medical implants by improving biocompatibility and modulating cellular behavior for biomedical applications. Variations in the surface structure and chemical composition of porous Al2O3 promote different biological responses and coating stability, underscoring the need for further biological and corrosion research. Traditional methods for producing alumina ceramics from powder are expensive, time-consuming, and limited in their ability to create complex shapes and large structures due to the brittleness of alumina. This study evaluates the biocompatibility of bioceramic-coated aluminum (Al) alloy 6082 as a lightweight and cost-effective alternative for bone osteosynthesis plates. Al2O3 coatings were achieved through anodization using phosphoric and sulfuric acids. The untreated and anodized alloys were analyzed for chemical stability and biocompatibility and compared with medical-grade titanium alloy. All specimens exhibited excellent biocompatibility, demonstrating high adhesion and viability of the fibroblast cell line. Corrosion resistance and metal ion release were assessed in simulated body fluid, with all specimens effectively suppressing the release of Fe and toxic Al ions. The untreated Al alloy exhibited a higher release of Mn ions than the coated specimens. Notably, the bioceramic coating obtained in sulfuric acid demonstrated 3 orders of magnitude higher corrosion resistance, indicating its potential suitability for biomedical applications. By addressing the limitations of traditional alumina ceramics, our approach enables the fabrication of products in diverse sizes and shapes, offering a practical solution for creating customized biomedical implants.
Collapse
Affiliation(s)
- Tadas Matijosius
- Faculty of Engineering, Vytautas Magnus University (VMU), Studentu 15, Akademija, Kaunas LT 53362, Lithuania
- Department of Chemical Engineering and Technology, State Research Institute Center for Physical Sciences and Technology, Sauletekio 3, Vilnius LT 10257, Lithuania
| | - Neringa Bakute
- Department of Functional Materials and Electronics, State Research Institute Center for Physical Sciences and Technology, Sauletekio 3, Vilnius LT 10257, Lithuania
| | - Juozas Padgurskas
- Faculty of Engineering, Vytautas Magnus University (VMU), Studentu 15, Akademija, Kaunas LT 53362, Lithuania
| | - Ausra Selskiene
- Department of Characterisation of Materials Structure, State Research Institute Center for Physical Sciences and Technology, Sauletekio 3, Vilnius LT 10257, Lithuania
| | - Aleksej Zarkov
- Institute of Chemistry, Vilnius University, Naugarduko 24, Vilnius LT-03225, Lithuania
| | - Asta Griguceviciene
- Department of Electrochemical Material Science, State Research Institute Center for Physical Sciences and Technology, Sauletekio 3, Vilnius LT 10257, Lithuania
| | - Justina Kavaliauskaite
- Department of Functional Materials and Electronics, State Research Institute Center for Physical Sciences and Technology, Sauletekio 3, Vilnius LT 10257, Lithuania
| | - Arunas Stirke
- Department of Functional Materials and Electronics, State Research Institute Center for Physical Sciences and Technology, Sauletekio 3, Vilnius LT 10257, Lithuania
| | - Svajus Joseph Asadauskas
- Department of Chemical Engineering and Technology, State Research Institute Center for Physical Sciences and Technology, Sauletekio 3, Vilnius LT 10257, Lithuania
| |
Collapse
|
3
|
Negrescu AM, Ionascu I, Necula MG, Tudor N, Kamaleev M, Zarnescu O, Mazare A, Schmuki P, Cimpean A. Lateral Spacing of TiO 2 Nanotube Coatings Modulates In Vivo Early New Bone Formation. Biomimetics (Basel) 2025; 10:81. [PMID: 39997104 PMCID: PMC11853438 DOI: 10.3390/biomimetics10020081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2024] [Revised: 01/23/2025] [Accepted: 01/24/2025] [Indexed: 02/26/2025] Open
Abstract
Due to the bio-inert nature of titanium (Ti) and subsequent accompanying chronic inflammatory response, an implant's stability and function can be significantly affected, which is why various surface modifications have been employed, including the deposition of titanium oxide (TiO2) nanotubes (TNTs) onto the native surface through the anodic oxidation method. While the influence of nanotube diameter on cell behaviour and osteogenesis is very well documented, information regarding the effects of nanotube lateral spacing on the in vivo new bone formation process is insufficient and hard to find. Considering this, the present study's aim was to evaluate the mechanical properties and the osteogenic ability of two types of TNTs-based pins with different lateral spacing, e.g., 25 nm (TNTs) and 92 nm (spTNTs). The mechanical properties of the TNT-coated implants were characterised from a morphological point of view (tube diameter, spacing, and tube length) using scanning electron microscopy (SEM). In addition, the chemical composition of the implants was evaluated using X-ray photoelectron spectroscopy, while surface roughness and topography were characterised using atomic force microscopy (AFM). Finally, the implants' hardness and elastic modulus were investigated using nanoindentation measurements. The in vivo new bone formation was histologically evaluated (haematoxylin and eosin-HE staining) at 6 and 30 days post-implantation in a rat model. Mechanical characterisation revealed that the two morphologies presented a similar chemical composition and mechanical strength, but, in terms of surface roughness, the spTNTs exhibited a higher average roughness. The microscopic examination at 1 month post-implantation revealed that spTNTs pins (57.21 ± 34.93) were capable of promoting early new bone tissue formation to a greater extent than the TNTs-coated implants (24.37 ± 6.5), with a difference in the average thickness of the newly formed bone tissue of ~32.84 µm, thus highlighting the importance of this parameter when designing future dental/orthopaedic implants.
Collapse
Affiliation(s)
- Andreea Mariana Negrescu
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91-95 Spl. Independentei, 050657 Bucharest, Romania; (A.M.N.); (M.G.N.); (O.Z.)
- Research Institute of the University of Bucharest (ICUB), University of Bucharest, 050657 Bucharest, Romania
| | - Iuliana Ionascu
- Faculty of Veterinary Medicine, University of Agronomic Sciences and Veterinary Medicine, 105 Spl. Independentei, 050097 Bucharest, Romania; (I.I.); (N.T.)
| | - Madalina Georgiana Necula
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91-95 Spl. Independentei, 050657 Bucharest, Romania; (A.M.N.); (M.G.N.); (O.Z.)
| | - Niculae Tudor
- Faculty of Veterinary Medicine, University of Agronomic Sciences and Veterinary Medicine, 105 Spl. Independentei, 050097 Bucharest, Romania; (I.I.); (N.T.)
| | - Maksim Kamaleev
- Department of Materials Science and Engineering, Chair of General Materials Properties, Friedrich-Alexander-University of Erlangen-Nürnberg, Martensstraße 5, 91058 Erlangen, Germany;
| | - Otilia Zarnescu
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91-95 Spl. Independentei, 050657 Bucharest, Romania; (A.M.N.); (M.G.N.); (O.Z.)
| | - Anca Mazare
- Department of Materials Science and Engineering, WW4-LKO, Friedrich-Alexander-University of Erlangen-Nürnberg, Martensstrasse 7, 91058 Erlangen, Germany;
| | - Patrik Schmuki
- Department of Materials Science and Engineering, WW4-LKO, Friedrich-Alexander-University of Erlangen-Nürnberg, Martensstrasse 7, 91058 Erlangen, Germany;
- Regional Centre of Advanced Technologies and Materials, Šlechtitelů 27, 78371 Olomouc, Czech Republic
| | - Anisoara Cimpean
- Department of Biochemistry and Molecular Biology, Faculty of Biology, University of Bucharest, 91-95 Spl. Independentei, 050657 Bucharest, Romania; (A.M.N.); (M.G.N.); (O.Z.)
| |
Collapse
|
4
|
Zhang J, Yu W, Li G, Li G, Chen B, Wang L, Yu Y, Liu Z, Li D. Robust and Regular Micronano Binary Texture on the Complex Curved Surface for Enhanced Reendothelialization and Antithrombotic Performance. ACS NANO 2025; 19:3676-3693. [PMID: 39813732 DOI: 10.1021/acsnano.4c14191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/18/2025]
Abstract
Blood-contacting medical devices can easily trigger immune responses, leading to thrombosis and hyperblastosis. Constructing microtexture that provides efficient antithrombotic and rapid reendothelialization performance on complex curved surfaces remains a pressing challenge. In this work, we present a robust and regular micronano binary texture on the titanium surface, characterized by exceptional mechanical strength and precisely controlled wettability to achieve excellent hemocompatibility. Systematic in vitro and in vivo investigations confirmed that the micronano binary texture with superhydrophilic modification effectively suppressed the adhesion and activation of plasma proteins and blood cells, thereby mitigating the subsequent coagulation cascade and thrombosis. Meanwhile, the modified surface significantly upregulated the gene expression involving cell-matrix adhesion, growth factor synthesis, and calcium-mediated cytoskeleton remodeling and then accelerated the formation of a healthy and stable endothelial cell layer. This enhancement of re-endothelialization was not observed with pure titanium and superhydrophobic surfaces. Hence, superhydrophilic micronano binary texture not only significantly inhibits thrombosis but also selectively enhances the integrity and viability of the endothelial cell layer, making it a promising strategy for improving the long-term anticoagulation performance of vascular implants.
Collapse
Affiliation(s)
- Jing Zhang
- Advanced Medical Research Institute, Cheeloo College of Medicine, Shandong University, Jinan 250012, P. R. China
| | - Wenyuan Yu
- Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, P. R. China
| | - Guoqiang Li
- Advanced Medical Research Institute, Cheeloo College of Medicine, Shandong University, Jinan 250012, P. R. China
| | - Guiling Li
- Advanced Medical Research Institute, Cheeloo College of Medicine, Shandong University, Jinan 250012, P. R. China
| | - Baolan Chen
- Advanced Medical Research Institute, Cheeloo College of Medicine, Shandong University, Jinan 250012, P. R. China
| | - Luwen Wang
- Advanced Medical Research Institute, Cheeloo College of Medicine, Shandong University, Jinan 250012, P. R. China
| | - Yang Yu
- Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, P. R. China
| | - Zhiyuan Liu
- CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institute of Advanced Technology Chinese Academy of Sciences (CAS), and the Guangdong-Hong Kong-Macao Joint Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen 518055, P. R. China
| | - Donghai Li
- Advanced Medical Research Institute, Cheeloo College of Medicine, Shandong University, Jinan 250012, P. R. China
| |
Collapse
|
5
|
Li Z, Sarikhani E, Prayotamornkul S, Meganathan DP, Jahed Z, Shi L. Multimodal Imaging Unveils the Impact of Nanotopography on Cellular Metabolic Activities. CHEMICAL & BIOMEDICAL IMAGING 2024; 2:825-834. [PMID: 39735831 PMCID: PMC11672213 DOI: 10.1021/cbmi.4c00051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2024] [Revised: 11/01/2024] [Accepted: 11/04/2024] [Indexed: 12/31/2024]
Abstract
Nanoscale surface topography is an effective approach in modulating cell-material interactions, significantly impacting cellular and nuclear morphologies, as well as their functionality. However, the adaptive changes in cellular metabolism induced by the mechanical and geometrical microenvironment of the nanotopography remain poorly understood. In this study, we investigated the metabolic activities in cells cultured on engineered nanopillar substrates by using a label-free multimodal optical imaging platform. This multimodal imaging platform, integrating two photon fluorescence (TPF) and stimulated Raman scattering (SRS) microscopy, allowed us to directly visualize and quantify metabolic activities of cells in 3D at the subcellular scale. We discovered that the nanopillar structure significantly reduced the cell spreading area and circularity compared to flat surfaces. Nanopillar-induced mechanical cues significantly modulate cellular metabolic activities with variations in nanopillar geometry further influencing these metabolic processes. Cells cultured on nanopillars exhibited reduced oxidative stress, decreased protein and lipid synthesis, and lower lipid unsaturation in comparison to those on flat substrates. Hierarchical clustering also revealed that pitch differences in the nanopillar had a more significant impact on cell metabolic activity than diameter variations. These insights improve our understanding of how engineered nanotopographies can be used to control cellular metabolism, offering possibilities for designing advanced cell culture platforms which can modulate cell behaviors and mimic natural cellular environment and optimize cell-based applications. By leveraging the unique metabolic effects of nanopillar arrays, one can develop more effective strategies for directing the fate of cells, enhancing the performance of cell-based therapies, and creating regenerative medicine applications.
Collapse
Affiliation(s)
- Zhi Li
- Shu
Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Einollah Sarikhani
- Aiiso
Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Sirasit Prayotamornkul
- Shu
Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Dhivya Pushpa Meganathan
- Shu
Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Zeinab Jahed
- Shu
Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, California 92093, United States
- Aiiso
Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Lingyan Shi
- Shu
Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, California 92093, United States
- Aiiso
Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States
- Electrical
and Computer Engineering, University of
California San Diego, La Jolla, California 92093, United States
- Institute
of Engineering in Medicine, University of
California San Diego, La Jolla, California 92093, United States
- Synthetic
Biology Institute, University of California
San Diego, La Jolla, California 92093, United States
| |
Collapse
|
6
|
Slepičková Kasálková N, Juřicová V, Fajstavr D, Frýdlová B, Rimpelová S, Švorčík V, Slepička P. Plasma-Activated Polydimethylsiloxane Microstructured Pattern with Collagen for Improved Myoblast Cell Guidance. Int J Mol Sci 2024; 25:2779. [PMID: 38474025 DOI: 10.3390/ijms25052779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2024] [Revised: 02/22/2024] [Accepted: 02/25/2024] [Indexed: 03/14/2024] Open
Abstract
We focused on polydimethylsiloxane (PDMS) as a substrate for replication, micropatterning, and construction of biologically active surfaces. The novelty of this study is based on the combination of the argon plasma exposure of a micropatterned PDMS scaffold, where the plasma served as a strong tool for subsequent grafting of collagen coatings and their application as cell growth scaffolds, where the standard was significantly exceeded. As part of the scaffold design, templates with a patterned microstructure of different dimensions (50 × 50, 50 × 20, and 30 × 30 μm2) were created by photolithography followed by pattern replication on a PDMS polymer substrate. Subsequently, the prepared microstructured PDMS replicas were coated with a type I collagen layer. The sample preparation was followed by the characterization of material surface properties using various analytical techniques, including scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray photoelectron spectroscopy (XPS). To evaluate the biocompatibility of the produced samples, we conducted studies on the interactions between selected polymer replicas and micro- and nanostructures and mammalian cells. Specifically, we utilized mouse myoblasts (C2C12), and our results demonstrate that we achieved excellent cell alignment in conjunction with the development of a cytocompatible surface. Consequently, the outcomes of this research contribute to an enhanced comprehension of surface properties and interactions between structured polymers and mammalian cells. The use of periodic microstructures has the potential to advance the creation of novel materials and scaffolds in tissue engineering. These materials exhibit exceptional biocompatibility and possess the capacity to promote cell adhesion and growth.
Collapse
Affiliation(s)
- Nikola Slepičková Kasálková
- Department of Solid State Engineering, The University of Chemistry and Technology Prague, 166 28 Prague, Czech Republic
| | - Veronika Juřicová
- Department of Solid State Engineering, The University of Chemistry and Technology Prague, 166 28 Prague, Czech Republic
| | - Dominik Fajstavr
- Department of Solid State Engineering, The University of Chemistry and Technology Prague, 166 28 Prague, Czech Republic
| | - Bára Frýdlová
- Department of Solid State Engineering, The University of Chemistry and Technology Prague, 166 28 Prague, Czech Republic
| | - Silvie Rimpelová
- Department of Biochemistry and Microbiology, The University of Chemistry and Technology Prague, 166 28 Prague, Czech Republic
| | - Václav Švorčík
- Department of Solid State Engineering, The University of Chemistry and Technology Prague, 166 28 Prague, Czech Republic
| | - Petr Slepička
- Department of Solid State Engineering, The University of Chemistry and Technology Prague, 166 28 Prague, Czech Republic
| |
Collapse
|
7
|
Lai CY, Liu CF, Lin TL, Chen MY, Huang YC, Huang HH, Dong CL, Wang DY, Yeh PH, Wu WW. Defect-Rich SnO 2 Nanofiber as an Oxygen-Defect-Driven Photoenergy Shield against UV Light Cell Damage. ACS APPLIED MATERIALS & INTERFACES 2023; 15:42868-42880. [PMID: 37647236 DOI: 10.1021/acsami.3c08926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Usually, most studies focus on toxic gas and photosensors by using electrospinning and metal oxide polycrystalline SnO2 nanofibers (PNFs), while fewer studies discuss cell-material interactions and photoelectric effect. In this work, the controllable surface morphology and oxygen defect (VO) structure properties were provided to show the opportunity of metal oxide PNFs to convert photoenergy into bio-energy for bio-material applications. Using the photobiomodulation effect of defect-rich polycrystalline SnO2 nanofibers (PNFs) is the main idea to modulate the cell-material interactions, such as adhesion, growth direction, and reactive oxygen species (ROS) density. The VO structures, including out-of-plane oxygen defects (op-VO), bridge oxygen defects (b-VO), and in-plane oxygen defects (ip-VO), were studied using synchrotron analysis to investigate the electron transfer between the VO structures and conduction bands. These intragrain VO structures can be treated as generation-recombination centers, which can convert various photoenergies (365-520 nm) into different current levels that form distinct surface potential levels; this is referred to as the photoelectric effect. PNF conductivity was enhanced 53.6-fold by enlarging the grain size (410 nm2) by increasing the annealing temperature, which can improve the photoelectric effect. In vitro removal of reactive oxygen species (ROS) can be achieved by using the photoelectric effect of PNFs. Also, the viability and shape of human bone marrow mesenchymal stem cells (hMSCs-BM) were also influenced significantly by the photobiomodulation effect. The cell damage and survival rate can be prevented and enhanced by using PNFs; metal oxide nanofibers are no longer only environmental sensors but can also be a bio-material to convert the photoenergy into bio-energy for biomedical science applications.
Collapse
Affiliation(s)
- Chun-Yen Lai
- Department of Materials Science and Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
| | - Chia-Fei Liu
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan
| | - Tzu-Ling Lin
- Department of Physics, Tamkang University, New Taipei 25137, Taiwan
| | - Mei-Yu Chen
- Department of Physics, Tamkang University, New Taipei 25137, Taiwan
| | - Yu-Cheng Huang
- Department of Electrophysics, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
| | - Her-Hsiung Huang
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan
| | - Chung-Li Dong
- Department of Physics, Tamkang University, New Taipei 25137, Taiwan
| | - Ding-Yeong Wang
- Department of Electrical Engineering, Feng Chia University, Taichung 407802, Taiwan
| | - Ping-Hung Yeh
- Department of Physics, Tamkang University, New Taipei 25137, Taiwan
| | - Wen-Wei Wu
- Department of Materials Science and Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
- Center for the Intelligent Semiconductor Nano-system Technology Research, Hsinchu 30078, Taiwan
| |
Collapse
|
8
|
Usseglio J, Dumur A, Pagès E, Renaudie É, Abélanet A, Brie J, Champion É, Magnaudeix A. Microporous Hydroxyapatite-Based Ceramics Alter the Physiology of Endothelial Cells through Physical and Chemical Cues. J Funct Biomater 2023; 14:460. [PMID: 37754874 PMCID: PMC10531673 DOI: 10.3390/jfb14090460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 08/15/2023] [Accepted: 08/22/2023] [Indexed: 09/28/2023] Open
Abstract
Incorporation of silicate ions in calcium phosphate ceramics (CPC) and modification of their multiscale architecture are two strategies for improving the vascularization of scaffolds for bone regenerative medicine. The response of endothelial cells, actors for vascularization, to the chemical and physical cues of biomaterial surfaces is little documented, although essential. We aimed to characterize in vitro the response of an endothelial cell line, C166, cultivated on the surface CPCs varying either in terms of their chemistry (pure versus silicon-doped HA) or their microstructure (dense versus microporous). Adhesion, metabolic activity, and proliferation were significantly altered on microporous ceramics, but the secretion of the pro-angiogenic VEGF-A increased from 262 to 386 pg/mL on porous compared to dense silicon-doped HA ceramics after 168 h. A tubulogenesis assay was set up directly on the ceramics. Two configurations were designed for discriminating the influence of the chemistry from that of the surface physical properties. The formation of tubule-like structures was qualitatively more frequent on dense ceramics. Microporous ceramics induced calcium depletion in the culture medium (from 2 down to 0.5 mmol/L), which is deleterious for C166. Importantly, this effect might be associated with the in vitro static cell culture. No influence of silicon doping of HA on C166 behavior was detected.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Amandine Magnaudeix
- Université de Limoges, CNRS, Institut de Recherche sur les Céramiques, UMR 7315, F-87000 Limoges, France; (J.U.); (A.D.); (E.P.); (É.R.); (A.A.); (J.B.); (É.C.)
| |
Collapse
|
9
|
Hu X, Xue Y, Liu D, Zhang J, Wang T, Wu Z, Lei W. Effects of material nano-topography on the angiogenesis of type H vessels: Size dependence, cell heterogeneity and intercellular communication. BIOMATERIALS ADVANCES 2023; 147:213307. [PMID: 36746099 DOI: 10.1016/j.bioadv.2023.213307] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Revised: 12/31/2022] [Accepted: 01/17/2023] [Indexed: 01/22/2023]
Abstract
Type H vessel, a vascular subtype in bone, is a critical regulator of osteogenesis, but how material properties affect this organ-specific vessel remains unknown. Here, titania nanotubes were fabricated on bone implant surface to investigate the effects of nano-topography on type H vessels. In vivo, surface nanotubes with 20-100 nm diameters promoted the angiogenesis of type H vessels and bone regeneration in mouse femurs to different extents, with the best effects induced by 70 nm diameter. In vitro, bone-specific endothelial cells (BECs) and artery endothelial cells (AECs) presented significantly different behaviors on the same material. Nanotubes with 20 nm small diameters significantly improved the adhesion, proliferation, type H differentiation of BECs and their paracrine function to regulate pre-osteoblasts (POBs), possibly via binding integrin β1 on the cell membrane, but these effects weakened when tube diameter increased, which conflicted with the results in vivo. Further study suggested that the better in vivo effects by larger diameters of 70-100 nm might be exerted indirectly through remodeling the regulation from POBs to BECs, highlighting the underappreciated indirect bio-effects of materials via intercellular communication. These suggest that nanoscale material topography makes significant impact on the angiogenesis of type H vessels, directly via binding integrins on the cell membrane of BECs and indirectly via modulating the regulation from osteoblastic cells to BECs, both in a size-dependent manner. Cells of the same type but from different tissues may show different responses to the same material, thus material properties should be tailored to the specific cell population. In research on material-tissue interactions, conclusions from in vitro experiments exposing a single type of cell to material might deviate from the truth in vivo, because materials may indirectly influence the targeted cells through modulating intercellular communication. These provide new insights into material-tissue interactions.
Collapse
Affiliation(s)
- Xiaofan Hu
- Department of Orthopedics, Xijing Hospital, The Fourth Military Medical University, Xi'an 710032, China
| | - Yumeng Xue
- State Key Laboratory of Solidification Processing, Center for Nano Energy Materials, School of Materials Science and Engineering, Northwestern Polytechnical University and Shaanxi Joint Laboratory of Graphene (NPU), Xi'an 710072, China
| | - Daming Liu
- Department of Orthopedics, Xijing Hospital, The Fourth Military Medical University, Xi'an 710032, China
| | - Jianming Zhang
- Department of Orthopedics, Xijing Hospital, The Fourth Military Medical University, Xi'an 710032, China
| | - Tianji Wang
- Department of Orthopedics, Xijing Hospital, The Fourth Military Medical University, Xi'an 710032, China
| | - Zixiang Wu
- Department of Orthopedics, Xijing Hospital, The Fourth Military Medical University, Xi'an 710032, China.
| | - Wei Lei
- Department of Orthopedics, Xijing Hospital, The Fourth Military Medical University, Xi'an 710032, China.
| |
Collapse
|
10
|
Wang B, Qinglai T, Yang Q, Li M, Zeng S, Yang X, Xiao Z, Tong X, Lei L, Li S. Functional acellular matrix for tissue repair. Mater Today Bio 2023; 18:100530. [PMID: 36601535 PMCID: PMC9806685 DOI: 10.1016/j.mtbio.2022.100530] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 12/23/2022] [Accepted: 12/26/2022] [Indexed: 12/29/2022] Open
Abstract
In view of their low immunogenicity, biomimetic internal environment, tissue- and organ-like physicochemical properties, and functionalization potential, decellularized extracellular matrix (dECM) materials attract considerable attention and are widely used in tissue engineering. This review describes the composition of extracellular matrices and their role in stem-cell differentiation, discusses the advantages and disadvantages of existing decellularization techniques, and presents methods for the functionalization and characterization of decellularized scaffolds. In addition, we discuss progress in the use of dECMs for cartilage, skin, nerve, and muscle repair and the transplantation or regeneration of different whole organs (e.g., kidneys, liver, uterus, lungs, and heart), summarize the shortcomings of using dECMs for tissue and organ repair after refunctionalization, and examine the corresponding future prospects. Thus, the present review helps to further systematize the application of functionalized dECMs in tissue/organ transplantation and keep researchers up to date on recent progress in dECM usage.
Collapse
Affiliation(s)
- Bin Wang
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha 410011, China
| | - Tang Qinglai
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha 410011, China
| | - Qian Yang
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha 410011, China
| | - Mengmeng Li
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha 410011, China
| | - Shiying Zeng
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha 410011, China
| | - Xinming Yang
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha 410011, China
| | - Zian Xiao
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha 410011, China
| | - Xinying Tong
- Department of Hemodialysis, The Second Xiangya Hospital, Central South University, Changsha 410011, Hunan, China
| | - Lanjie Lei
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Shisheng Li
- Department of Otorhinolaryngology Head and Neck Surgery, The Second Xiangya Hospital, Central South University, Changsha 410011, China
| |
Collapse
|
11
|
Zhang Y, Jiang N, Gan Z. Poly(ε-Caprolactone) Substrates with Micro/Nanohierarchical Patterned Structures for Cell Culture. Macromol Biosci 2022; 22:e2200300. [PMID: 36086924 DOI: 10.1002/mabi.202200300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 08/23/2022] [Indexed: 01/15/2023]
Abstract
A simple, efficient and controllable one-step template method is proposed to fabricate poly(ε-caprolactone) substrates with micro/nanohierarchical patterned structures. Two kinds of geometric patterns with and without nanowires, i.e., hexagonal and strip with controllable island size and spacing are designed and fabricated. Furthermore, the influence of geometric patterns, island size, island spacing, and patterned nanowires (pNW) on the growth behavior of MG-63 cells is studied in terms of cell density, distribution, proliferation, morphogenesis, and cellular alignment. It is found that MG-63 cells prefer to adhere and grow on the substrate with smaller island size or spacing. Moreover, unlike the hexagonal structure, the strip structure can guide cellular alignment on its surface. In addition, the microisland structures and the pNW play different roles in promoting cell proliferation, distribution, and morphogenesis. It is concluded that the growth behavior of MG-63 cells can be well controlled by precisely adjusting the micro/nanostructure of the substrate surface. A simple and effective method is provided here for the regulation of cell growth behavior.
Collapse
Affiliation(s)
- Yuan Zhang
- State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, Beijing Advanced Innovation Center for Soft Matter Science and Engineering, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Ni Jiang
- State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, Beijing Advanced Innovation Center for Soft Matter Science and Engineering, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Zhihua Gan
- State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, Beijing Advanced Innovation Center for Soft Matter Science and Engineering, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China
| |
Collapse
|
12
|
Avery D, Morandini L, Sheakley LS, Shah AH, Bui L, Abaricia JO, Olivares-Navarrete R. Canonical Wnt signaling enhances pro-inflammatory response to titanium by macrophages. Biomaterials 2022; 289:121797. [PMID: 36156410 PMCID: PMC10262842 DOI: 10.1016/j.biomaterials.2022.121797] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 08/22/2022] [Accepted: 09/05/2022] [Indexed: 11/19/2022]
Abstract
Biomaterial characteristics like surface roughness and wettability can determine the phenotype of macrophages following implantation. We have demonstrated that inhibiting Wnt ligand secretion abolishes macrophage polarization in vitro and in vivo; however, the role of canonical Wnt signaling in macrophage activation in response to physical and chemical biomaterial cues is unknown. The aim of this study was to understand whether canonical Wnt signaling affects the response of macrophages to titanium (Ti) surface roughness or wettability in vitro and in vivo. Activating canonical Wnt signaling increased expression of toll-like receptors and interleukin receptors and secreted pro-inflammatory cytokines and reduced anti-inflammatory cytokines on Ti, regardless of surface properties. Inhibiting canonical Wnt signaling reduced pro-inflammatory cytokines on all Ti surfaces and increased anti-inflammatory cytokines on rough or rough-hydrophilic Ti. In vivo, activating canonical Wnt signaling increased total macrophages, pro-inflammatory macrophages, and T cells and decreased anti-inflammatory macrophages on both smooth and rough-hydrophilic implants. Functionally, canonical Wnt activation increases pro-inflammatory macrophage response to cell and cell-extracellular matrix lysates. These results demonstrate that activating canonical Wnt signaling primes macrophages to a pro-inflammatory phenotype that affects their response to Ti implants in vitro and in vivo.
Collapse
Affiliation(s)
- Derek Avery
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, VA, United States
| | - Lais Morandini
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, VA, United States
| | - Luke S Sheakley
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, VA, United States
| | - Arth H Shah
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, VA, United States
| | - Loc Bui
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, VA, United States
| | - Jefferson O Abaricia
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, VA, United States
| | - Rene Olivares-Navarrete
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, VA, United States.
| |
Collapse
|
13
|
Ogura N, Berger MB, Srivas P, Hwang S, Li J, Cohen DJ, Schwartz Z, Boyan BD, Sandhage KH. Tailoring of TiAl6V4 Surface Nanostructure for Enhanced In Vitro Osteoblast Response via Gas/Solid (Non-Line-of-Sight) Oxidation/Reduction Reactions. Biomimetics (Basel) 2022; 7:biomimetics7030117. [PMID: 36134921 PMCID: PMC9496476 DOI: 10.3390/biomimetics7030117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 08/12/2022] [Accepted: 08/17/2022] [Indexed: 11/26/2022] Open
Abstract
An aging global population is accelerating the need for better, longer-lasting orthopaedic and dental implants. Additive manufacturing can provide patient-specific, titanium-alloy-based implants with tailored, three-dimensional, bone-like architecture. Studies using two-dimensional substrates have demonstrated that osteoblastic differentiation of bone marrow stromal cells (MSCs) is enhanced on surfaces possessing hierarchical macro/micro/nano-scale roughness that mimics the topography of osteoclast resorption pits on the bone surface. Conventional machined implants with these surfaces exhibit successful osseointegration, but the complex architectures produced by 3D printing make consistent nanoscale surface texturing difficult to achieve, and current line-of-sight methods used to roughen titanium alloy surfaces cannot reach all internal surfaces. Here, we demonstrate a new, non-line-of-sight, gas/solid-reaction-based process capable of generating well-controlled nanotopographies on all open (gas-exposed) surfaces of titanium alloy implants. Dense 3D-printed titanium-aluminum-vanadium (TiAl6V4) substrates were used to evaluate the evolution of surface nanostructure for development of this process. Substrates were either polished to be smooth (for easier evaluation of surface nanostructure evolution) or grit-blasted and acid-etched to present a microrough biomimetic topography. An ultrathin (90 ± 16 nm) conformal, titania-based surface layer was first formed by thermal oxidation (600 °C, 6 h, air). A calciothermic reduction (CaR) reaction (700 °C, 1 h) was then used to convert the surface titania (TiO2) into thin layers of calcia (CaO, 77 ± 16 nm) and titanium (Ti, 51 ± 20 nm). Selective dissolution of the CaO layer (3 M acetic acid, 40 min) then yielded a thin nanoporous/nanorough Ti-based surface layer. The changes in surface nanostructure/chemistry after each step were confirmed by scanning and transmission electron microscopies with energy-dispersive X-ray analysis, X-ray diffraction, selected area electron diffraction, atomic force microscopy, and mass change analyses. In vitro studies indicated that human MSCs on CaR-modified microrough surfaces exhibited increased protein expression associated with osteoblast differentiation and promoted osteogenesis compared to unmodified microrough surfaces (increases of 387% in osteopontin, 210% in osteocalcin, 282% in bone morphogenic protein 2, 150% in bone morphogenic protein 4, 265% in osteoprotegerin, and 191% in vascular endothelial growth factor). This work suggests that this CaR-based technique can provide biomimetic topography on all biologically facing surfaces of complex, porous, additively manufactured TiAl6V4 implants.
Collapse
Affiliation(s)
- Naotaka Ogura
- School of Materials Engineering, Purdue University, W. Lafayette, IN 47907, USA
| | - Michael B. Berger
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA
| | - Pavan Srivas
- School of Materials Engineering, Purdue University, W. Lafayette, IN 47907, USA
| | - Sunghwan Hwang
- School of Materials Engineering, Purdue University, W. Lafayette, IN 47907, USA
| | - Jiaqi Li
- School of Materials Engineering, Purdue University, W. Lafayette, IN 47907, USA
| | - David Joshua Cohen
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA
| | - Zvi Schwartz
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA
- Correspondence: (Z.S.); (B.D.B.); (K.H.S.)
| | - Barbara D. Boyan
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA
- Correspondence: (Z.S.); (B.D.B.); (K.H.S.)
| | - Kenneth H. Sandhage
- School of Materials Engineering, Purdue University, W. Lafayette, IN 47907, USA
- Correspondence: (Z.S.); (B.D.B.); (K.H.S.)
| |
Collapse
|
14
|
Kaewmanee R, Wang F, Pan Y, Mei S, Meesane J, Li F, Wu Z, Wei J. Microporous surface containing flower-like molybdenum disulfide submicro-spheres of sulfonated polyimide with antibacterial effect and promoting bone regeneration and osteointegration. Biomater Sci 2022; 10:4243-4256. [PMID: 35762466 DOI: 10.1039/d2bm00622g] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Implanted materials with both osteogenic and antibacterial functions are promising for facilitating osteointegration and preventing infection for orthopedic applications. In this work, we synthesized flower-like molybdenum disulfide (fMD) submicro-spheres containing nanosheets, which were incorporated onto the microporous surface of polyimide (PI) via concentrated sulfuric acid, suspending fMD contents of 5 wt% (SPM1) and 10 wt% (SPM2). Compared with sulfonated polyimide (SPM0), both SPM1 and SPM2 with microporous surfaces containing fMD exhibited nano-submicro-microporous surfaces, which improved the surface roughness, wettability, and surface energy. Due to there being more fMD submicro-spheres on the microporous surface, SPM2 revealed a better antibacterial effect than SPM1. In addition, compared with SPM1 and SPM0, SPM2 with more fMD significantly promoted rat bone marrow-derived stromal cell response in vitro. Moreover, SPM2 remarkably enhanced new bone formation and osteointegration in vivo. In summary, the combination of fMD with the microporous surface of SPM2 resulted in a nano-submicro-microporous surface with optimized surface performance, which possessed not only osteogenic bioactivity but also an antibacterial effect. As a bone implant, SPM2 with osteogenic and antibacterial functions may have enormous potential as a bone tissue substitute.
Collapse
Affiliation(s)
- Rames Kaewmanee
- Shanghai Key Laboratory of Advanced Polymeric Materials, Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai, 200237, China.
| | - Fan Wang
- Shanghai Key Laboratory of Advanced Polymeric Materials, Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai, 200237, China.
| | - Yongkang Pan
- Shanghai Key Laboratory of Advanced Polymeric Materials, Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai, 200237, China.
| | - Shiqi Mei
- Shanghai Key Laboratory of Advanced Polymeric Materials, Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai, 200237, China.
| | - Jirut Meesane
- Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Songkla, Thailand
| | - Fengqian Li
- Shanghai Eighth People's Hospital, Shanghai 200235, China.
| | - Zhaoying Wu
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, Guangdong, 518107, China.
| | - Jie Wei
- Shanghai Key Laboratory of Advanced Polymeric Materials, Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai, 200237, China.
| |
Collapse
|
15
|
Palierse E, Roquart M, Norvez S, Corté L. Coatings of hydroxyapatite-bioactive glass microparticles for adhesion to biological tissues. RSC Adv 2022; 12:21079-21091. [PMID: 35919836 PMCID: PMC9305725 DOI: 10.1039/d2ra02781j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 06/29/2022] [Indexed: 12/03/2022] Open
Abstract
Adsorption of particles across interfaces has been proposed as a way to create adhesion between hydrogels and biological tissues. Here, we explore how this particle bridging approach can be applied to attach a soft polymer substrate to biological tissues, using bioresorbable and nanostructured hydroxyapatite-bioactive glass microparticles. For this, microparticles of aggregated flower-like hydroxyapatite and bioactive glass (HA-BG) were synthesized via a bioinspired route. A deposition technique using suspension spreading was developed to tune the coverage of HA-BG coatings at the surface of weakly cross-linked poly(beta-thioester) films. By varying the concentration of the deposited suspensions, we produced coatings having surface coverages ranging from 4% to 100% and coating densities ranging from 0.02 to 1.0 mg cm-2. The progressive dissolution of these coatings within 21 days in phosphate-buffered saline was followed by SEM. Ex vivo peeling experiments on pig liver capsules demonstrated that HA-BG coatings produce an up-to-two-fold increase in adhesion energy (9.8 ± 1.5 J m-2) as compared to the uncoated film (4.6 ± 0.8 J m-2). Adhesion energy was found to increase with increasing coating density until a maximum at 0.2 mg cm-2, well below full surface coverage, and then it decreased for larger coating densities. Using microscopy observations during and after peeling, we show that this maximum in adhesion corresponds to the appearance of particle stacks, which are easily separated and transferred onto the tissue. Such bioresorbable HA-BG coatings give the possibility of combining particle bridging with the storage and release of active compounds, therefore offering opportunities to design functional bioadhesive surfaces.
Collapse
Affiliation(s)
- Estelle Palierse
- Molecular, Macromolecular Chemistry, and Materials, ESPCI Paris, CNRS, PSL University 75005 Paris France
| | - Maïlie Roquart
- Molecular, Macromolecular Chemistry, and Materials, ESPCI Paris, CNRS, PSL University 75005 Paris France
- Centre des Matériaux, MINES Paris, CNRS, PSL University 91003 Evry France
| | - Sophie Norvez
- Molecular, Macromolecular Chemistry, and Materials, ESPCI Paris, CNRS, PSL University 75005 Paris France
| | - Laurent Corté
- Molecular, Macromolecular Chemistry, and Materials, ESPCI Paris, CNRS, PSL University 75005 Paris France
- Centre des Matériaux, MINES Paris, CNRS, PSL University 91003 Evry France
| |
Collapse
|
16
|
Pellegrino L, Kriem LS, Robles ESJ, Cabral JT. Microbial Response to Micrometer-Scale Multiaxial Wrinkled Surfaces. ACS APPLIED MATERIALS & INTERFACES 2022; 14:31463-31473. [PMID: 35699282 PMCID: PMC9284519 DOI: 10.1021/acsami.2c08768] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We investigate the effect of micrometer-scale surface wrinkling on the attachment and proliferation of model bacteria (Staphylococcus aureus, Pseudomonas aeruginosa, and Escherichia coli K12) and fungi (Candida albicans). Specifically, sinusoidal (1D), checkerboard (C), and herringbone (H) patterns were fabricated by mechanical wrinkling of plasma-oxidized polydimethylsiloxane (PDMS) bilayers and contrasted with flat (F) surfaces. Microbial deformation and orientation were found to correlate with the aspect ratio and commensurably with surface pattern dimensions and local pattern order. Significantly, the proliferation of P. aeruginosa could be described by a linear scaling between bacterial area coverage and available surface area, defined as a fraction of the line integral along each profile with negative curvature. However, in the early stages of proliferation (up to 6 h examined), that C and H patterns disrupt the spatial arrangement of bacteria, impeding proliferation for several hours and reducing it (by ∼50%) thereafter. Our findings suggest a simple framework to rationalize the impact of micrometer-scale topography on microbial action and demonstrate that multiaxial patterning order provides an effective strategy to delay and frustrate the early stages of bacterial proliferation.
Collapse
Affiliation(s)
- Luca Pellegrino
- Department
of Chemical Engineering, Imperial College
London, London SW7 2AZ, United Kingdom
| | - Lukas Simon Kriem
- Fraunhofer
Institute for Interfacial Engineering and Biotechnology IGB, Nobelstrasse 12, 70569 Stuttgart, Germany
| | - Eric S. J. Robles
- Procter
& Gamble, Newcastle Innovation Centre, Newcastle upon Tyne NE12
9TS, United Kingdom
| | - João T. Cabral
- Department
of Chemical Engineering, Imperial College
London, London SW7 2AZ, United Kingdom
| |
Collapse
|
17
|
Wu B, Tang Y, Wang K, Zhou X, Xiang L. Nanostructured Titanium Implant Surface Facilitating Osseointegration from Protein Adsorption to Osteogenesis: The Example of TiO 2 NTAs. Int J Nanomedicine 2022; 17:1865-1879. [PMID: 35518451 PMCID: PMC9064067 DOI: 10.2147/ijn.s362720] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 04/20/2022] [Indexed: 02/05/2023] Open
Abstract
Titanium implants have been widely applied in dentistry and orthopedics due to their biocompatibility and resistance to mechanical fatigue. TiO2 nanotube arrays (TiO2 NTAs) on titanium implant surfaces have exhibited excellent biocompatibility, bioactivity, and adjustability, which can significantly promote osseointegration and participate in its entire path. In this review, to give a comprehensive understanding of the osseointegration process, four stages have been divided according to pivotal biological processes, including protein adsorption, inflammatory cell adhesion/inflammatory response, additional relevant cell adhesion and angiogenesis/osteogenesis. The impact of TiO2 NTAs on osseointegration is clarified in detail from the four stages. The nanotubular layer can manipulate the quantity, the species and the conformation of adsorbed protein. For inflammatory cells adhesion and inflammatory response, TiO2 NTAs improve macrophage adhesion on the surface and induce M2-polarization. TiO2 NTAs also facilitate the repairment-related cells adhesion and filopodia formation for additional relevant cells adhesion. In the angiogenesis and osteogenesis stage, TiO2 NTAs show the ability to induce osteogenic differentiation and the potential for blood vessel formation. In the end, we propose the multi-dimensional regulation of TiO2 NTAs on titanium implants to achieve highly efficient manipulation of osseointegration, which may provide views on the rational design and development of titanium implants.
Collapse
Affiliation(s)
- Bingfeng Wu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | - Yufei Tang
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, People's Republic of China.,Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | - Kai Wang
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | - Xuemei Zhou
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan, People's Republic of China
| | - Lin Xiang
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, People's Republic of China.,Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, People's Republic of China
| |
Collapse
|
18
|
Tan YH, Helms HR, Nakayama KH. Decellularization Strategies for Regenerating Cardiac and Skeletal Muscle Tissues. Front Bioeng Biotechnol 2022; 10:831300. [PMID: 35295645 PMCID: PMC8918733 DOI: 10.3389/fbioe.2022.831300] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Accepted: 01/28/2022] [Indexed: 12/24/2022] Open
Abstract
Cardiovascular disease is the leading cause of death worldwide and is associated with approximately 17.9 million deaths each year. Musculoskeletal conditions affect more than 1.71 billion people globally and are the leading cause of disability. These two areas represent a massive global health burden that is perpetuated by a lack of functionally restorative treatment options. The fields of regenerative medicine and tissue engineering offer great promise for the development of therapies to repair damaged or diseased tissues. Decellularized tissues and extracellular matrices are cornerstones of regenerative biomaterials and have been used clinically for decades and many have received FDA approval. In this review, we first discuss and compare methods used to produce decellularized tissues and ECMs from cardiac and skeletal muscle. We take a focused look at how different biophysical properties such as spatial topography, extracellular matrix composition, and mechanical characteristics influence cell behavior and function in the context of regenerative medicine. Lastly, we describe emerging research and forecast the future high impact applications of decellularized cardiac and skeletal muscle that will drive novel and effective regenerative therapies.
Collapse
Affiliation(s)
| | | | - Karina H. Nakayama
- Department of Biomedical Engineering, Oregon Health and Science University, Portland, OR, United States
| |
Collapse
|
19
|
Xu Y, Yu G, Nie R, Wu Z. Microfluidic systems toward blood hemostasis monitoring and thrombosis diagnosis: From design principles to micro/nano fabrication technologies. VIEW 2022. [DOI: 10.1002/viw.20200183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Affiliation(s)
- Yi Xu
- Soft Intelligence Lab State Key Laboratory of Digital Manufacturing Equipment and Technology School of Mechanical Science and Engineering Huazhong University of Science and Technology Wuhan China
| | - Guang Yu
- Experimental Medicine Center Tongji Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan China
| | - Ruqiong Nie
- Department of Cardiology Sun Yat‐Sen Memorial Hospital Sun Yat‐Sen University Guangzhou China
| | - Zhigang Wu
- Soft Intelligence Lab State Key Laboratory of Digital Manufacturing Equipment and Technology School of Mechanical Science and Engineering Huazhong University of Science and Technology Wuhan China
| |
Collapse
|
20
|
Raza S, Li X, Soyekwo F, Liao D, Xiang Y, Liu C. A comprehensive overview of common conducting polymer-based nanocomposites; Recent advances in design and applications. Eur Polym J 2021. [DOI: 10.1016/j.eurpolymj.2021.110773] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
21
|
Moghaddaszadeh A, Seddiqi H, Najmoddin N, Abbasi Ravasjani S, Klein-Nulend J. Biomimetic 3D-printed PCL scaffold containing a high concentration carbonated-nanohydroxyapatite with immobilized-collagen for bone tissue engineering: enhanced bioactivity and physicomechanical characteristics. Biomed Mater 2021; 16. [PMID: 34670200 DOI: 10.1088/1748-605x/ac3147] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Accepted: 10/20/2021] [Indexed: 11/12/2022]
Abstract
A challenging approach of three-dimensional (3D)-biomimetic scaffold design for bone tissue engineering is to improve scaffold bioactivity and mechanical properties. We aimed to design and fabricate 3D-polycaprolactone (PCL)-based nanocomposite scaffold containing a high concentration homogeneously distributed carbonated-nanohydroxyapatite (C-nHA)-particles in combination with immobilized-collagen to mimic real bone properties. PCL-scaffolds without/with C-nHA at 30%, 45%, and 60% (wt/wt) were 3D-printed. PCL/C-nHA60%-scaffolds were surface-modified by NaOH-treatment and collagen-immobilization. Physicomechanical and biological properties were investigated experimentally and by finite-element (FE) modeling. Scaffold surface-roughness enhanced by increasing C-nHA (1.7 - 6.1-fold), but decreased by surface-modification (0.6-fold). The contact angle decreased by increasing C-nHA (0.9 - 0.7-fold), and by surface-modification (0.5-fold). The zeta potential decreased by increasing C-nHA (3.2-9.9-fold). Average elastic modulus, compressive strength, and reaction force enhanced by increasing C-nHA and by surface-modification. FE modeling revealed that von Mises stress distribution became less homogeneous by increasing C-nHA, and by surface-modification. Maximal von Mises stress for 2% compression strain in all scaffolds did not exceed yield stress for bulk-material. 3D-printed PCL/C-nHA60% with surface-modification enhanced pre-osteoblast spreading, proliferation, collagen deposition, alkaline phosphatase activity, and mineralization. In conclusion, a novel biomimetic 3D-printed PCL-scaffold containing a high concentration C-nHA with surface-modification was successfully fabricated. It exhibited superior physicomechanical and biological properties, making it a promising biomaterial for bone tissue engineering.
Collapse
Affiliation(s)
- Ali Moghaddaszadeh
- Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Hadi Seddiqi
- Department of Oral Cell Biology, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, 1081 LA, The Netherlands
| | - Najmeh Najmoddin
- Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | | | - Jenneke Klein-Nulend
- Department of Oral Cell Biology, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, 1081 LA, The Netherlands
| |
Collapse
|
22
|
Mesenchymal Stem Cells, Bioactive Factors, and Scaffolds in Bone Repair: From Research Perspectives to Clinical Practice. Cells 2021; 10:cells10081925. [PMID: 34440694 PMCID: PMC8392210 DOI: 10.3390/cells10081925] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 07/24/2021] [Accepted: 07/27/2021] [Indexed: 02/06/2023] Open
Abstract
Mesenchymal stem cell-based therapies are promising tools for bone tissue regeneration. However, tracking cells and maintaining them in the site of injury is difficult. A potential solution is to seed the cells onto a biocompatible scaffold. Construct development in bone tissue engineering is a complex step-by-step process with many variables to be optimized, such as stem cell source, osteogenic molecular factors, scaffold design, and an appropriate in vivo animal model. In this review, an MSC-based tissue engineering approach for bone repair is reported. Firstly, MSC role in bone formation and regeneration is detailed. Secondly, MSC-based bone tissue biomaterial design is analyzed from a research perspective. Finally, examples of animal preclinical and human clinical trials involving MSCs and scaffolds in bone repair are presented.
Collapse
|
23
|
Lian M, Sun B, Han Y, Yu B, Xin W, Xu R, Ni B, Jiang W, Hao Y, Zhang X, Shen Y, Qiao Z, Dai K. A low-temperature-printed hierarchical porous sponge-like scaffold that promotes cell-material interaction and modulates paracrine activity of MSCs for vascularized bone regeneration. Biomaterials 2021; 274:120841. [PMID: 33984633 DOI: 10.1016/j.biomaterials.2021.120841] [Citation(s) in RCA: 51] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 03/31/2021] [Accepted: 04/16/2021] [Indexed: 12/11/2022]
Abstract
Mesenchymal stem cells (MSCs) secrete paracrine trophic factors that are beneficial for tissue regeneration. In this study, a sponge-like scaffold with hierarchical and interconnected pores was developed using low-temperature deposition modeling (LDM) printing. Its effects on the cellular behavior, especially on the paracrine secretion patterns of MSCs, were comprehensively investigated. We found that compared with the scaffolds printed via the fused deposition modeling (FDM) technique, the LDM-printed sponges enhanced the adhesion, retention, survival, and ingrowth of MSCs and promoted cell-material interactions. Moreover, the paracrine functions of the cultured MSCs on the LDM-printed sponges were improved, with significant secretion of upregulated immunomodulatory, angiogenic, and osteogenic factors. MSCs on the LDM-printed sponges exert beneficial paracrine effects on multiple regenerative processes, including macrophage polarization, tube formation, and osteogenesis, verifying the enhanced immunomodulatory, angiogenic, and osteogenic potential. Further protein function assays indicated that focal adhesion kinase (FAK), downstream AKT, and yes-associated-protein (YAP) signaling might participate in the required mechanotransductive pathways, through which the hierarchical porous structures stimulated the paracrine effects of MSCs. In a rat distal femoral defect model, the MSC-laden LDM-printed sponges significantly promoted vascularized bone regeneration. The results of the present study demonstrate that the hierarchical porous biomimetic sponges prepared via LDM printing have potential applications in tissue engineering based on their cell-material interaction promotion and MSC paracrine function modulation effects. Furthermore, our findings suggest that the optimization of biomaterial properties to direct the paracrine signaling of MSCs would enhance tissue regeneration.
Collapse
Affiliation(s)
- Meifei Lian
- Clinical and Translational Research Center for 3D Printing Technology, Medical 3D Printing Innovation Research Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200125, China; Department of Prosthodontics, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Binbin Sun
- Clinical and Translational Research Center for 3D Printing Technology, Medical 3D Printing Innovation Research Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200125, China; Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Yu Han
- Clinical and Translational Research Center for 3D Printing Technology, Medical 3D Printing Innovation Research Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200125, China; Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Bin Yu
- Department of Oral & Cranio-Maxillofacial Surgery, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Weiwei Xin
- Department of Orthopaedic Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 201112, China
| | - Ruida Xu
- Department of Orthopaedic Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 201112, China
| | - Bing Ni
- School of Life Science, East China Normal University, Shanghai, 200241, China
| | - Wenbo Jiang
- Clinical and Translational Research Center for 3D Printing Technology, Medical 3D Printing Innovation Research Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200125, China; Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Yongqiang Hao
- Clinical and Translational Research Center for 3D Printing Technology, Medical 3D Printing Innovation Research Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200125, China; Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Xiuyin Zhang
- Department of Prosthodontics, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Yi Shen
- Department of Orthopaedic Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 201112, China.
| | - Zhiguang Qiao
- Clinical and Translational Research Center for 3D Printing Technology, Medical 3D Printing Innovation Research Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200125, China; Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China; Department of Orthopaedic Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 201112, China.
| | - Kerong Dai
- Clinical and Translational Research Center for 3D Printing Technology, Medical 3D Printing Innovation Research Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200125, China; Department of Orthopaedic Surgery, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
| |
Collapse
|
24
|
Nobles KP, Janorkar AV, Williamson RS. Surface modifications to enhance osseointegration-Resulting material properties and biological responses. J Biomed Mater Res B Appl Biomater 2021; 109:1909-1923. [PMID: 33871951 DOI: 10.1002/jbm.b.34835] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 02/26/2021] [Accepted: 03/14/2021] [Indexed: 12/18/2022]
Abstract
As life expectancy and the age of the general population increases so does the need for improved implants. A major contributor to the failure of implants is poor osseointegration, which is typically described as the direct connection between bone and implant. This leads to unnecessary complications and an increased burden on the patient population. Modification of the implant surfaces through novel techniques, such as varying topography and/or applying coatings, has become a popular method to enhance the osseointegration capability of implants. Recent research has shown that particular surface features influence how bone cells interact with a material; however, it is unknown which exact features achieve optimal bone integration. In this review, current methods of modifying surfaces will be highlighted, and the resulting surface characteristics and biological responses are discussed. Review of the current strategies of surface modifications found that many coating types are more advantageous when used in combination; however, finding a surface modification that utilizes the mutual beneficial effects of important surface characteristics while still maintaining commercial viability is where future challenges exist.
Collapse
Affiliation(s)
- Kadie P Nobles
- Department of Biomedical Materials Science, School of Dentistry, University of Mississippi Medical Center, Jackson, Mississippi, USA
| | - Amol V Janorkar
- Department of Biomedical Materials Science, School of Dentistry, University of Mississippi Medical Center, Jackson, Mississippi, USA
| | - Randall S Williamson
- Department of Biomedical Materials Science, School of Dentistry, University of Mississippi Medical Center, Jackson, Mississippi, USA
| |
Collapse
|
25
|
Mohd Roslan MR, Mohd Kamal NL, Abdul Khalid MF, Mohd Nasir NF, Cheng EM, Beh CY, Tan JS, Mohamed MS. The State of Starch/Hydroxyapatite Composite Scaffold in Bone Tissue Engineering with Consideration for Dielectric Measurement as an Alternative Characterization Technique. MATERIALS 2021; 14:ma14081960. [PMID: 33919814 PMCID: PMC8070798 DOI: 10.3390/ma14081960] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 03/21/2021] [Accepted: 03/27/2021] [Indexed: 01/06/2023]
Abstract
Hydroxyapatite (HA) has been widely used as a scaffold in tissue engineering. HA possesses high mechanical stress and exhibits particularly excellent biocompatibility owing to its similarity to natural bone. Nonetheless, this ceramic scaffold has limited applications due to its apparent brittleness. Therefore, this had presented some difficulties when shaping implants out of HA and for sustaining a high mechanical load. Fortunately, these drawbacks can be improved by combining HA with other biomaterials. Starch was heavily considered for biomedical device applications in favor of its low cost, wide availability, and biocompatibility properties that complement HA. This review provides an insight into starch/HA composites used in the fabrication of bone tissue scaffolds and numerous factors that influence the scaffold properties. Moreover, an alternative characterization of scaffolds via dielectric and free space measurement as a potential contactless and nondestructive measurement method is also highlighted.
Collapse
Affiliation(s)
- Mohd Riza Mohd Roslan
- Biomedical Electronic Engineering Program, School of Mechatronic Engineering, Universiti Malaysia Perlis, Arau 02600, Perlis, Malaysia; (M.R.M.R.); (N.F.M.N.); (E.M.C.); (C.Y.B.)
| | - Nadhiya Liyana Mohd Kamal
- Malaysian Institute of Aviation Technology, Universiti Kuala Lumpur, Dengkil 43800, Selangor, Malaysia;
| | - Muhammad Farid Abdul Khalid
- Faculty of Electrical Engineering, Microwave Research Institute (MRI), Universiti Teknologi MARA (UiTM), Shah Alam 40450, Selangor, Malaysia;
| | - Nashrul Fazli Mohd Nasir
- Biomedical Electronic Engineering Program, School of Mechatronic Engineering, Universiti Malaysia Perlis, Arau 02600, Perlis, Malaysia; (M.R.M.R.); (N.F.M.N.); (E.M.C.); (C.Y.B.)
- Sports Engineering Research Centre (SERC), Universiti Malaysia Perlis, Arau 02600, Perlis, Malaysia
| | - Ee Meng Cheng
- Biomedical Electronic Engineering Program, School of Mechatronic Engineering, Universiti Malaysia Perlis, Arau 02600, Perlis, Malaysia; (M.R.M.R.); (N.F.M.N.); (E.M.C.); (C.Y.B.)
| | - Chong You Beh
- Biomedical Electronic Engineering Program, School of Mechatronic Engineering, Universiti Malaysia Perlis, Arau 02600, Perlis, Malaysia; (M.R.M.R.); (N.F.M.N.); (E.M.C.); (C.Y.B.)
| | - Joo Shun Tan
- Bioprocess Technology, School of Industrial Technology, Universiti Sains Malaysia, Gelugor 11800, Pulau Pinang, Malaysia;
- Bioprocessing and Biomanufacturing Research Centre, Universiti Putra Malaysia (UPM), Serdang 43400, Selangor, Malaysia
| | - Mohd Shamzi Mohamed
- Bioprocessing and Biomanufacturing Research Centre, Universiti Putra Malaysia (UPM), Serdang 43400, Selangor, Malaysia
- Department of Bioprocess Technology, Universiti Putra Malaysia (UPM), Serdang 43400, Selangor, Malaysia
- Correspondence:
| |
Collapse
|
26
|
A biomimetic basement membrane consisted of hybrid aligned nanofibers and microfibers with immobilized collagen IV and laminin for rapid endothelialization. Biodes Manuf 2021. [DOI: 10.1007/s42242-020-00111-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
27
|
Nanoscale mechanical properties of chitosan hydrogels as revealed by AFM. Prog Biomater 2020; 9:187-201. [PMID: 33156481 DOI: 10.1007/s40204-020-00141-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 10/08/2020] [Indexed: 01/25/2023] Open
Abstract
In the context of tissue engineering, chitosan hydrogels are attractive biomaterials because they represent a family of natural polymers exhibiting several suitable features (cytocompatibility, bioresorbability, wound healing, bacteriostatic and fungistatic properties, structural similarity with glycosaminoglycans), and tunable mechanical properties. Optimizing the design of these biomaterials requires fine knowledge of its physical characteristics prior to assessment of the cell-biomaterial interactions. In this work, using atomic force microscopy (AFM), we report a characterization of mechanical and topographical properties at the submicron range of chitosan hydrogels, depending on physico-chemical parameters such as their polymer concentration (1.5%, 2.5% and 3.5%), their degree of acetylation (4% and 38.5%), and the conditions of the gelation process. Well-known polyacrylamide gels were used to validate the methodology approach for the determination and analysis of elastic modulus (i.e., Young's modulus) distribution at the gel surface. We present elastic modulus distribution and topographical and stiffness maps for different chitosan hydrogels. For each chitosan hydrogel formulation, AFM analyses reveal a specific asymmetric elastic modulus distribution that constitutes a useful hallmark for chitosan hydrogel characterization. Our results regarding the local mechanical properties and the topography of chitosan hydrogels initiate new possibilities for an interpretation of the behavior of cells in contact with such soft materials.
Collapse
|
28
|
Clainche TL, Linklater D, Wong S, Le P, Juodkazis S, Guével XL, Coll JL, Ivanova EP, Martel-Frachet V. Mechano-Bactericidal Titanium Surfaces for Bone Tissue Engineering. ACS APPLIED MATERIALS & INTERFACES 2020; 12:48272-48283. [PMID: 33054152 DOI: 10.1021/acsami.0c11502] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Despite advances in the development of bone substitutes and strict aseptic procedures, the majority of failures in bone grafting surgery are related to nosocomial infections. Development of biomaterials combining both osteogenic and antibiotic activity is, therefore, a crucial public health issue. Herein, two types of intrinsically bactericidal titanium supports were fabricated by using commercially scalable techniques: plasma etching or hydrothermal treatment, which display two separate mechanisms of mechano-bactericidal action. Hydrothermal etching produces a randomly nanostructured surface with sharp nanosheet protrusions killing bacteria via cutting of the cell membrane, whereas plasma etching of titanium produces a microscale two-tier hierarchical topography that both reduce bacterial attachment and rupture those bacteria that encounter the surface. The adhesion, growth, and proliferation of human adipose-derived stem cells (hASCs) on the two mechano-bactericidal topographies were assessed. Both types of supports allowed the growth and proliferation of the hASCs in the same manner and cells retained their stemness and osteogenic potential. Furthermore, these supports induced osteogenic differentiation of hASCs without the need of differentiation factors, demonstrating their osteoinductive properties. This study proves that these innovative mechano-bactericidal titanium surfaces with both regenerative and bactericidal properties are a promising solution to improve the success rate of reconstructive surgery.
Collapse
Affiliation(s)
- Tristan Le Clainche
- Cancer Target and Experimental Therapeutics, Institute for Advanced Biosciences, INSERM U1209, UMR CNRS 5309, Grenoble Alpes University, Site Santé, Allée des Alpes, 38700 La Tronche, France
| | - Denver Linklater
- School of Science, RMIT University, Melbourne, VIC 3000, Australia
| | - Sherman Wong
- School of Science, RMIT University, Melbourne, VIC 3000, Australia
| | - Phuc Le
- School of Science, RMIT University, Melbourne, VIC 3000, Australia
| | - Saulius Juodkazis
- Optical Sciences Centre and ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), School of Science, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| | - Xavier Le Guével
- Cancer Target and Experimental Therapeutics, Institute for Advanced Biosciences, INSERM U1209, UMR CNRS 5309, Grenoble Alpes University, Site Santé, Allée des Alpes, 38700 La Tronche, France
| | - Jean-Luc Coll
- Cancer Target and Experimental Therapeutics, Institute for Advanced Biosciences, INSERM U1209, UMR CNRS 5309, Grenoble Alpes University, Site Santé, Allée des Alpes, 38700 La Tronche, France
| | - Elena P Ivanova
- School of Science, RMIT University, Melbourne, VIC 3000, Australia
| | - Véronique Martel-Frachet
- Cancer Target and Experimental Therapeutics, Institute for Advanced Biosciences, INSERM U1209, UMR CNRS 5309, Grenoble Alpes University, Site Santé, Allée des Alpes, 38700 La Tronche, France
- EPHE, PSL Research University, 75014 Paris, France
| |
Collapse
|
29
|
Yaşayan G, Mega Tiber P, Orun O, Alarçin E. Doxorubicin hydrochloride loaded nanotextured films as a novel drug delivery platform for ovarian cancer treatment. Pharm Dev Technol 2020; 25:1289-1301. [PMID: 32930020 DOI: 10.1080/10837450.2020.1823992] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
An approach for cancer treatment is modulation of tumor microenvironment. Based on the role of extracellular matrix in cell modulation, fabrication of textured materials mimicking extracellular matrix could provide novel opportunities such as determining cancer cell behaviour. With this background, in this work, we have fabricated doxorubicin hydrochloride loaded nanotextured films which promote topographical attachment of cancer cells to film surface, and eliminate cells by release of the anti-cancer drug encapsulated within the films. These films are designed to be placed during surgical removal of the tumor with the intent to prevent ovarian cancer recurrence by capturing cancer cell residuals. With this aim, hemispherical protrusion shaped surface textures were acquired using colloidal lithography technique using 280 nm, 210 nm or 99 nm polystyrene particles. Once moulds were formed, nanotextured films were obtained by casting water-in-oil stable polycaprolactone emulsions encapsulating doxorubicin hydrochloride. Films were then characterized, and evaluated as drug delivery systems. According to results, we found that template morphologies were successfully transferred to films by atomic force microscopy studies. Hydrophilic surfaces were formed with contact angle values around 40°. In-vitro drug release studies indicated that nanotextured films best fit into the Higuchi model, and ∼30% of the drug is released from the films within 60 days. Cell culture results indicated increases in the attachment and viability of human ovarian cancer cells to nanotextured surfaces, particularly to the film fabricated using 99 nm particles. Our results demonstrated that delivery of anti-cancer drugs by use of nanotextured materials could be efficient in cancer therapy, and may offer new possibilities for cancer treatment.
Collapse
Affiliation(s)
- Gökçen Yaşayan
- Department of Pharmaceutical Technology, Faculty of Pharmacy, Marmara University, Istanbul, Turkey
| | - Pınar Mega Tiber
- Department of Biophysics, Faculty of Medicine, Marmara University, İstanbul, Turkey
| | - Oya Orun
- Department of Biophysics, Faculty of Medicine, Marmara University, İstanbul, Turkey
| | - Emine Alarçin
- Department of Pharmaceutical Technology, Faculty of Pharmacy, Marmara University, Istanbul, Turkey
| |
Collapse
|
30
|
Guo B, Tang C, Wang M, Zhao Z, Shokoohi‐Tabrizi HA, Shi B, Andrukhov O, Rausch‐Fan X. In vitro biocompatibility of biohybrid polymers membrane evaluated in human gingival fibroblasts. J Biomed Mater Res B Appl Biomater 2020; 108:2590-2598. [PMID: 32096606 PMCID: PMC7383566 DOI: 10.1002/jbm.b.34591] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Accepted: 02/11/2020] [Indexed: 12/14/2022]
Abstract
The biohybrid polymer membrane (BHM) is a new biomaterial designed for the treatment of soft periodontal tissue defects. We aimed to evaluate the in vitro biocompatibility of the membrane in human gingival fibroblasts and the capability to induce cell adhesion, migration, differentiation and improving the production of the extracellular matrix. BHM and Mucograft® collagen matrix (MCM) membranes were punched into 6 mm diameter round discs and placed in 96-well plates. Human primary gingival fibroblasts were seeded on the membranes or tissue culture plastic (TCP) serving as the control. Cell proliferation/viability and morphology were evaluated after 3, 7, and 14 days of culture by cell counting kit (CCK)-8 assay and scanning electron microscopy, respectively. Additionally, the gene expression of transforming growth factor (TGF)-β1, focal adhesion kinase (FAK), collagen type 1 (Col1), alpha-smooth muscle actin (α-SMA), and fibroblasts growth factor (FGF)-2 was analyzed at 3, 7, and 14 days of culture by qPCR. Cell proliferation on BHM was significantly higher than on MCM and similar to TCP. Gene expression of TGF-β1, FAK, Col1, and α-SMA were significantly increased on BHM compared to TCP at most investigated time points. However, the gene expression of FGF-2 was significantly decreased on BHM at Day 7 and recovered at Day 14 to the levels similar to TCP. The finding of this study showed that BHM is superior for gingival fibroblasts in terms of adhesion, proliferation, and gene expression, suggesting that this membrane may promote the healing of soft periodontal tissue.
Collapse
Affiliation(s)
- Bin Guo
- Department of StomatologyJinan Central Hospital affiliated to Shandong UniversityJinanShandongChina
- Division of Periodontology and Conservative DentistryUniversity Clinic of Dentistry, Medical University of ViennaViennaAustria
| | - Chuhua Tang
- Division of Periodontology and Conservative DentistryUniversity Clinic of Dentistry, Medical University of ViennaViennaAustria
- Department of StomatologyPLA Strategic Support Force Characteristic Medical CenterBeijingChina
| | - Mingguo Wang
- Department of StomatologyJinan Central Hospital affiliated to Shandong UniversityJinanShandongChina
| | - Zhongqi Zhao
- Division of Periodontology and Conservative DentistryUniversity Clinic of Dentistry, Medical University of ViennaViennaAustria
| | - Hassan A. Shokoohi‐Tabrizi
- Division of Periodontology and Conservative DentistryUniversity Clinic of Dentistry, Medical University of ViennaViennaAustria
| | - Bin Shi
- Department of Oral and Maxillofacial SurgeryThe First Affiliated Hospital of Fujian Medical UniversityFuzhouFujianChina
| | - Oleh Andrukhov
- Division of Periodontology and Conservative DentistryUniversity Clinic of Dentistry, Medical University of ViennaViennaAustria
| | - Xiaohui Rausch‐Fan
- Division of Periodontology and Conservative DentistryUniversity Clinic of Dentistry, Medical University of ViennaViennaAustria
- Department of Oral and Maxillofacial SurgeryThe First Affiliated Hospital of Fujian Medical UniversityFuzhouFujianChina
| |
Collapse
|
31
|
The Effectiveness of Nafion-Coated Stainless Steel Surfaces for Inhibiting Bacillus Subtilis Biofilm Formation. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10145001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Stainless steel is one of most commonly used materials in the world; however, biofilms on the surfaces of stainless steel cause many serious problems. In order to find effective methods of reducing bacterial adhesion to stainless steel, and to investigate the role of electrostatic effects during the formation of biofilms, this study used a stainless steel surface that was negatively charged by being coated with Nafion which was terminated by sulfonic groups. The results showed that the roughness of stainless steel discs coated with 1% Nafion was similar to an uncoated surface; however the hydrophobicity increased, and the Nafion-coated surface reduced the adhesion of Bacillus subtilis by 75% compared with uncoated surfaces. Therefore, a facile way to acquire antibacterial stainless steel was found, and it is proved that electrostatic effects have a significant influence on the formation of biofilms.
Collapse
|
32
|
Zhang Q, Tong Z, Chen F, Wang X, Ren M, Zhao Y, Wu P, He X, Chen P, Chen Y. Aligned soy protein isolate-modified poly(L-lactic acid) nanofibrous conduits enhanced peripheral nerve regeneration. J Neural Eng 2020; 17:036003. [PMID: 32340001 DOI: 10.1088/1741-2552/ab8d81] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVE Repair and regeneration of peripheral nerve defect by engineered conduits have greatly advanced in the past decades while still facing great challenges. APPROACH In this work, we fabricated a new highly oriented poly(L-lactic acid) (PLLA)/soy protein isolate (SPI) nanofibrous conduit (HO-PSNC) for nerve regeneration. MAIN RESULTS Firstly, we observed that SPI could efficiently modify PLLA for the electrospinning of PLLA/SPI nanofibers with enhanced physical and biological properties. Incorporation of SPI decreased the fiber diameter and ductility of PLLA/SPI nanofibrous films (PSNFs), improved the tensile strength and surface wettability of PSNFs and increased the in vivo degradability of the PSNFs. When the hybrid ratio of SPI was 20 and 40%, PSNFs could efficiently promote neural cell extension and differentiation in vitro. Based on these data, 20% SPI (PSNF-20) was chosen for further investigation. Next, PSNF-20 with different fiber orientations (random/low orientation, medium, and high orientation, respectively) were developed and used for evaluating neural cell behaviors on the materials. Results revealed that the PSNF-20 with highly oriented nanofibers (HO-PSNF-20) or mediumly oriented nanofibers (MO-PSNF-20) showed a better performance in directing cell extension and enhancing neurite outgrowth. Finally, the highly oriented nanofibers conduits (HO-PSNC-20) were used to bridge sciatic nerve defect in rats with highly oriented PLLA and autografts as controls. HO-PSNC-20 exhibited a significant promotion in nerve regeneration and functional reconstruction comparing to highly oriented PLLA as proven by the evaluations of walking track, electrophysiology, toluidine blue nerve staining, transmission electron microscopy, neural factors staining and qPCR, and gastrocnemius histology. SIGNIFICANCE In conclusion, nerve conduit fabricated from aligned electrospinning of SPI-modified PLLA nanofibers is promising for peripheral nerve regeneration.
Collapse
Affiliation(s)
- Qiang Zhang
- Department of Biomedical Engineering and Hubei Province Key Laboratory of Allergy and Immune Related Diseases, School of Basic Medical Sciences, Wuhan University, Wuhan 430071, People's Republic of China. Hangzhou Singclean Medical Products Co., Ltd., Hangzhou 310018, People's Republic of China
| | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Zheng H, Tian Y, Gao Q, Yu Y, Xia X, Feng Z, Dong F, Wu X, Sui L. Hierarchical Micro-Nano Topography Promotes Cell Adhesion and Osteogenic Differentiation via Integrin α2-PI3K-AKT Signaling Axis. Front Bioeng Biotechnol 2020; 8:463. [PMID: 32509748 PMCID: PMC7248375 DOI: 10.3389/fbioe.2020.00463] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Accepted: 04/21/2020] [Indexed: 12/17/2022] Open
Abstract
Surface topography dictates important aspects of cell biological behaviors. In our study, hierarchical micro-nano topography (SLM-AHT) with micro-scale grooves and nano-scale pores was fabricated and compared with smooth topography (S) and irregular micro-scale topography (SLA) surfaces to investigate mechanism involved in cell-surface interactions. Integrin α2 had a higher expression level on SLM-AHT surface compared with S and SLA surfaces, and the expression levels of osteogenic markers icluding Runx2, Col1a1, and Ocn were concomitantly upregulated on SLM-AHT surface. Moreover, formation of mature focal adhesions were significantly enhanced in SLM-AHT group. Noticablely, silencing integrin α2 could wipe out the difference of osteogenic gene expression among surfaces with different topography, indicating a crucial role of integrin α2 in topography induced osteogenic differentiation. In addition, PI3K-AKT signaling was proved to be regulated by integrin α2 and consequently participate in this process. Taken together, our findings illustrated that integrin α2-PI3K-AKT signaling axis plays a key role in hierarchical micro-nano topography promoting cell adhesion and osteogenic differentiation.
Collapse
Affiliation(s)
- Huimin Zheng
- Department of Prosthodontics, School and Hospital of Stomatology, Tianjin Medical University, Tianjin, China
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Yujuan Tian
- Department of Prosthodontics, School and Hospital of Stomatology, Tianjin Medical University, Tianjin, China
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Qian Gao
- Department of Prosthodontics, School and Hospital of Stomatology, Tianjin Medical University, Tianjin, China
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Yingjie Yu
- Health Science Center, Institute of Translational Medicine, The First Affiliated Hospital of Shenzhen University, Shenzhen, China
| | - Xianyou Xia
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Zhipeng Feng
- Department of Prosthodontics, School and Hospital of Stomatology, Tianjin Medical University, Tianjin, China
| | - Feng Dong
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Xudong Wu
- Department of Cell Biology, 2011 Collaborative Innovation Center of Tianjin for Medical Epigenetics, Tianjin Key Laboratory of Medical Epigenetics, Tianjin Medical University, Tianjin, China
| | - Lei Sui
- Department of Prosthodontics, School and Hospital of Stomatology, Tianjin Medical University, Tianjin, China
| |
Collapse
|
34
|
Mertgen AS, Trossmann VT, Guex AG, Maniura-Weber K, Scheibel T, Rottmar M. Multifunctional Biomaterials: Combining Material Modification Strategies for Engineering of Cell-Contacting Surfaces. ACS APPLIED MATERIALS & INTERFACES 2020; 12:21342-21367. [PMID: 32286789 DOI: 10.1021/acsami.0c01893] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
In the human body, cells in a tissue are exposed to signals derived from their specific extracellular matrix (ECM), such as architectural structure, mechanical properties, and chemical composition (proteins, growth factors). Research on biomaterials in tissue engineering and regenerative medicine aims to recreate such stimuli using engineered materials to induce a specific response of cells at the interface. Although traditional biomaterials design has been mostly limited to varying individual signals, increasing interest has arisen on combining several features in recent years to improve the mimicry of extracellular matrix properties. Tremendous progress in combinatorial surface modification exploiting, for example, topographical features or variations in mechanics combined with biochemical cues has enabled the identification of their key regulatory characteristics on various cell fate decisions. Gradients especially facilitated such research by enabling the investigation of combined continuous changes of different signals. Despite unravelling important synergies for cellular responses, challenges arise in terms of fabrication and characterization of multifunctional engineered materials. This review summarizes recent work on combinatorial surface modifications that aim to control biological responses. Modification and characterization methods for enhanced control over multifunctional material properties are highlighted and discussed. Thereby, this review deepens the understanding and knowledge of biomimetic combinatorial material modification, their challenges but especially their potential.
Collapse
Affiliation(s)
- Anne-Sophie Mertgen
- Laboratory for Biointerfaces, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, St. Gallen 9014, Switzerland
- Laboratory for Biomimetic Membranes and Textiles, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, St. Gallen 9014, Switzerland
| | - Vanessa Tanja Trossmann
- Lehrstuhl für Biomaterialien, Universität Bayreuth, Prof.-Rüdiger-Bormann-Strasse 1, Bayreuth 95440, Germany
| | - Anne Géraldine Guex
- Laboratory for Biointerfaces, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, St. Gallen 9014, Switzerland
- Laboratory for Biomimetic Membranes and Textiles, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, St. Gallen 9014, Switzerland
| | - Katharina Maniura-Weber
- Laboratory for Biointerfaces, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, St. Gallen 9014, Switzerland
| | - Thomas Scheibel
- Lehrstuhl für Biomaterialien, Bayerisches Polymerinstitut (BPI), Bayreuther Zentrum für Kolloide und Grenzflächen (BZKG), Bayreuther Zentrum für Molekulare Biowissenschaften (BZMB), Bayreuther Materialzentrum (BayMAT), Universität Bayreuth, Bayreuth 95440, Germany
| | - Markus Rottmar
- Laboratory for Biointerfaces, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, St. Gallen 9014, Switzerland
| |
Collapse
|
35
|
Yu C, Xing M, Wang L, Guan G. Effects of aligned electrospun fibers with different diameters on hemocompatibility, cell behaviors and inflammation in vitro. Biomed Mater 2020; 15:035005. [DOI: 10.1088/1748-605x/ab673c] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
36
|
Higgins SG, Becce M, Belessiotis-Richards A, Seong H, Sero JE, Stevens MM. High-Aspect-Ratio Nanostructured Surfaces as Biological Metamaterials. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2020; 32:e1903862. [PMID: 31944430 PMCID: PMC7610849 DOI: 10.1002/adma.201903862] [Citation(s) in RCA: 115] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 10/02/2019] [Indexed: 04/14/2023]
Abstract
Materials patterned with high-aspect-ratio nanostructures have features on similar length scales to cellular components. These surfaces are an extreme topography on the cellular level and have become useful tools for perturbing and sensing the cellular environment. Motivation comes from the ability of high-aspect-ratio nanostructures to deliver cargoes into cells and tissues, access the intracellular environment, and control cell behavior. These structures directly perturb cells' ability to sense and respond to external forces, influencing cell fate, and enabling new mechanistic studies. Through careful design of their nanoscale structure, these systems act as biological metamaterials, eliciting unusual biological responses. While predominantly used to interface eukaryotic cells, there is growing interest in nonanimal and prokaryotic cell interfacing. Both experimental and theoretical studies have attempted to develop a mechanistic understanding for the observed behaviors, predominantly focusing on the cell-nanostructure interface. This review considers how high-aspect-ratio nanostructured surfaces are used to both stimulate and sense biological systems.
Collapse
Affiliation(s)
- Stuart G. Higgins
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
| | | | | | - Hyejeong Seong
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
| | - Julia E. Sero
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
| | - Molly M. Stevens
- Department of Materials, Imperial College London, London, SW7 2AZ, UK
- Department of Bioengineering, Imperial College London, London, SW7 2AZ, UK
- Institute of Biomedical Engineering, Imperial College London, London, SW7 2AZ, UK
| |
Collapse
|
37
|
Sun Y, Hu C, Yang Y, Dong B, Deng Y. Fibroin/peptide co-functionalized calcium titanate nanorods improve osteoinductivity of titanium via mimicking osteogenic niche. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 103:109836. [DOI: 10.1016/j.msec.2019.109836] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 03/25/2019] [Accepted: 05/29/2019] [Indexed: 12/11/2022]
|
38
|
Banville FA, Moreau J, Chabot K, Cattoni A, Fröhlich U, Bryche JF, Collin S, Charette PG, Grandbois M, Canva M. Nanoplasmonics-enhanced label-free imaging of endothelial cell monolayer integrity. Biosens Bioelectron 2019; 141:111478. [PMID: 31280004 DOI: 10.1016/j.bios.2019.111478] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 06/21/2019] [Accepted: 06/24/2019] [Indexed: 01/24/2023]
Abstract
Surface plasmon resonance imaging (SPRI) is a powerful label-free imaging modality for the analysis of morphological dynamics in cell monolayers. However, classical plasmonic imaging systems have relatively poor spatial resolution along one axis due to the plasmon mode attenuation distance (tens of μm, typically), which significantly limits their ability to resolve subcellular structures. We address this limitation by adding an array of nanostructures onto the metal sensing surface (25 nm thick, 200 nm width, 400 nm period grating) to couple localized plasmons with propagating plasmons, thereby reducing attenuation length and commensurately increasing spatial imaging resolution, without significant loss of sensitivity or image contrast. In this work, experimental results obtained with both conventional unstructured and nanostructured gold film SPRI sensor chips show a clear gain in spatial resolution achieved with surface nanostructuring. The work demonstrates the ability of the nanostructured SPRI chips to resolve fine morphological detail (intercellular gaps) in experiments monitoring changes in endothelial cell monolayer integrity following the activation of the cell surface protease-activated receptor 1 (PAR1) by thrombin. In particular, the nanostructured chips reveal the persistence of small intercellular gaps (<5 μm2) well after apparent recovery of cell monolayer integrity as determined by conventional unstructured surface based SPRI. This new high spatial resolution plasmonic imaging technique uses low-cost and reusable patterned substrates and is likely to find applications in cell biology and pharmacology by allowing label-free quantification of minute cell morphological activities associated with receptor dependent intracellular signaling activity.
Collapse
Affiliation(s)
- Frederic A Banville
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Institut Interdisciplinaire d'Innovation Technologique (3IT), Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Laboratoire Charles Fabry (LCF), Institut d'Optique Graduate School, Université Paris-Saclay, CNRS, Palaiseau, 91127, France
| | - Julien Moreau
- Laboratoire Charles Fabry (LCF), Institut d'Optique Graduate School, Université Paris-Saclay, CNRS, Palaiseau, 91127, France
| | - Kevin Chabot
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Institut Interdisciplinaire d'Innovation Technologique (3IT), Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada
| | - Andrea Cattoni
- Centre de Nanosciences et de Nanotechnologies (C2N), CNRS UMR-9001, Université Paris-Sud/Paris-Saclay, Palaiseau, 91120, France
| | - Ulrike Fröhlich
- Département de Pharmacologie et Physiologie, Institut de Pharmacologie de Sherbrooke (IPS), Université de Sherbrooke, Canada
| | - Jean-François Bryche
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Institut Interdisciplinaire d'Innovation Technologique (3IT), Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada
| | - Stéphane Collin
- Centre de Nanosciences et de Nanotechnologies (C2N), CNRS UMR-9001, Université Paris-Sud/Paris-Saclay, Palaiseau, 91120, France
| | - Paul G Charette
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Institut Interdisciplinaire d'Innovation Technologique (3IT), Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada
| | - Michel Grandbois
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Département de Pharmacologie et Physiologie, Institut de Pharmacologie de Sherbrooke (IPS), Université de Sherbrooke, Canada
| | - Michael Canva
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Institut Interdisciplinaire d'Innovation Technologique (3IT), Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Laboratoire Charles Fabry (LCF), Institut d'Optique Graduate School, Université Paris-Saclay, CNRS, Palaiseau, 91127, France.
| |
Collapse
|
39
|
Ammann KR, Li M, Hossainy S, Slepian MJ. The Influence of Polymer Processing Methods on Polymer Film Physical Properties and Vascular Cell Responsiveness. ACS APPLIED BIO MATERIALS 2019; 2:3234-3244. [PMID: 32944709 PMCID: PMC7494131 DOI: 10.1021/acsabm.9b00175] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Implantable vascular devices typically interface with blood and vascular tissues. Physical properties of device materials and coatings, independent of chemical composition, can significantly influence cell responses and implant success. Here, we analyzed the effect of various polymer processing regimes, using a single implant polymer - poly(ε-caprolactone) (PCL), on vascular endothelial cell (EC), smooth muscle cell (SMC), and platelet response. PCL films were formed by varying three parameters: 1) formation method - solvent casting, melt pressing or spin coating; 2) molecular weight - 50 or 100 kDa; and 3) solvent type - dichloromethane (DCM) or tetrahydrofuran (THF). We quantified the relationship of polymer processing choice to surface roughness, wettability, and bulk stiffness; and to EC adhesion, SMC adhesion, and platelet activity state (PAS). Multiple regression analysis identified which processing method signficantly impacted (F-ratio>p-value; p<0.1) polymer physical properties and vascular cell interaction. Film formation method affected PCL roughness (Rq), wettability (°), and stiffness (MPa) with spin coating resulting in the most wettable (81.8±0.7°), and stiffest (1.12±0.07 MPa; p<0.001) polymer film; however, solvent cast films were the roughest (281±66nm). Molecular weight influenced wettability, with the highest wettability on 50 kDa films (79.7±0.7°; p<0.001) and DCM solvent films (83.0±1.0°; p<0.01). The multiple regression model confidently predicted (F-ratio=9.88; p=0.005) wettability from molecular weight (p=0.002) and film formation method (p=0.03); stiffness (F-ratio=4.21; p=0.05) also fit well tofilm formation method (p=0.02). Film formation method impacted SMC adhesion and platelet activity state, but not EC adhesion, with melt press PCL promoting the highest SMC adhesion (18000±1536 SMCs; p<0.05) and PAS (5.0±0.7 %PAS). The regression model confidently fit SMC adhesion (F-ratio=3.15; p=0.09) and PAS (F-ratio=5.30; p=0.05) to polymer processing choices, specifically film formation method (p<0.03). However, only SMC adhesion had a model that fit well (F-ratio=4.13; p=0.05) to the physical properties directly, specifically roughness and wettability (p<0.04).
Collapse
Affiliation(s)
- Kaitlyn R. Ammann
- Department of Biomedical Engineering, College of Engineering, The University of Arizona, Tucson, AZ 85721, United States
| | - Maxwell Li
- Department of Biomedical Engineering, College of Engineering, The University of Arizona, Tucson, AZ 85721, United States
| | - Syed Hossainy
- Department of Bioengineering, College of Engineering, The University of California Berkeley, Berkeley, CA, 94720
| | - Marvin J. Slepian
- Department of Biomedical Engineering, College of Engineering, The University of Arizona, Tucson, AZ 85721, United States
- Department of Medicine, College of Medicine, The University of Arizona, Tucson, AZ 85721, United States
- Sarver Heart Center, The University of Arizona, Tucson, AZ 85721, United States
| |
Collapse
|
40
|
Yu C, Xing M, Sun S, Guan G, Wang L. In vitro evaluation of vascular endothelial cell behaviors on biomimetic vascular basement membranes. Colloids Surf B Biointerfaces 2019; 182:110381. [PMID: 31351274 DOI: 10.1016/j.colsurfb.2019.110381] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 07/15/2019] [Accepted: 07/18/2019] [Indexed: 12/14/2022]
Abstract
Vascular basement membrane (VBM) is a thin layer of fibrous extracellular matrix linking endothelium, and collagen type IV (COL IV) is its main composition. VBM plays a crucial role in anchoring down the endothelium to its loose connective tissue underneath. For vascular grafts, constructing biomimetic VBMs on the luminal surface is thus an effective approach to improve endothelialization in situ. In the present work, three types of polycaprolactone (PCL) membranes were produced and characterized through cell counting kit-8 (CCK-8) assay, adhesion force and elastic modulus test to examine the influence of fiber diameter and membrane composition on vascular endothelial cell (EC) behaviors. The PCL membranes with finer fibers of 54.77 nm (PCL-54) could biomimic the nanotopography of VBMs more efficiently than 544.64 nm (PCL-544), and they were more suitable for Pig iliac endothelium cells (PIECs) adhesion and proliferation, meanwhile, inducing higher elastic modulus and adhesion force of PIECs. On this foundation, we further immobilized COL IV onto PCL-54 (PCL-COL IV) to biomimic VBMs compositionally. Results showed that PIECs on PCL-COL IV exhibited the highest viability and proliferation. Besides, quantitative data indicated that the elastic modulus of the PIECs on PCL-COL IV (4441.00 Pa) was as two times higher than that on PCL-54 (2312.26 Pa), and the adhesion force grew to 1120.99 pN from 673.58 pN of PIECs on PCL-54. In summary, the PCL-COL IV membranes show high similarity with the native VBMs in terms of structure and composition, suggesting a promising potential for surface modification to vascular grafts for improved endothelialization.
Collapse
Affiliation(s)
- Chenglong Yu
- Engineering Research Center of Technical Textile, Ministry of Education, Key Laboratory of Textile Science and Technology of Ministry of Education, Key Laboratory of Textile Industry for Biomedical Textile materials and Technology, College of Textiles, Donghua University, 2999 North Renmin Road, Shanghai, 201620, China
| | - Meiyi Xing
- Engineering Research Center of Technical Textile, Ministry of Education, Key Laboratory of Textile Science and Technology of Ministry of Education, Key Laboratory of Textile Industry for Biomedical Textile materials and Technology, College of Textiles, Donghua University, 2999 North Renmin Road, Shanghai, 201620, China
| | - Shibo Sun
- Engineering Research Center of Technical Textile, Ministry of Education, Key Laboratory of Textile Science and Technology of Ministry of Education, Key Laboratory of Textile Industry for Biomedical Textile materials and Technology, College of Textiles, Donghua University, 2999 North Renmin Road, Shanghai, 201620, China
| | - Guoping Guan
- Engineering Research Center of Technical Textile, Ministry of Education, Key Laboratory of Textile Science and Technology of Ministry of Education, Key Laboratory of Textile Industry for Biomedical Textile materials and Technology, College of Textiles, Donghua University, 2999 North Renmin Road, Shanghai, 201620, China.
| | - Lu Wang
- Engineering Research Center of Technical Textile, Ministry of Education, Key Laboratory of Textile Science and Technology of Ministry of Education, Key Laboratory of Textile Industry for Biomedical Textile materials and Technology, College of Textiles, Donghua University, 2999 North Renmin Road, Shanghai, 201620, China.
| |
Collapse
|
41
|
Cell Morphology on Poly(methyl methacrylate) Microstructures as Function of Surface Energy. Int J Biomater 2019; 2019:2393481. [PMID: 31186649 PMCID: PMC6521382 DOI: 10.1155/2019/2393481] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 03/22/2019] [Accepted: 04/07/2019] [Indexed: 12/24/2022] Open
Abstract
Whilst the significance of substrate topography as a regulator of cell function is well established, a systematic analysis of the principles underlying this is still unavailable. Here we evaluate the hypothesis that surface energy plays a decisive role in substrate-mediated modulation of cell phenotype by evaluation of cell behaviour on synthetic microstructures exhibiting pronounced differences in surface energy. These microstructures, specifically cubes and walls, were fabricated from a biocompatible base polymer, poly(methyl methacrylate), by variotherm injection molding. The dimensions of the cubes were 1 μm x 1 μm x 1 μm (height x width x length) with a periodicity of 1:1 and 1:5 and the dimensions of the walls 1 μm x 1 μm x 15 mm (height x width x length) with a periodicity of 1:1 and 1:5. Mold inserts were made by lithography and electroplating. The surface energy of the resultant microstructures was determined by static contact angle measurements. Light scanning microscopy of the morphology of NT2/D1 and MC3T3-E1 preosteoblast cells cultured on structured PMMA samples in both cases revealed a profound surface energy dependence. “Walls” appeared to promote significant cell elongation, whilst a lack of cell adhesion was observed on “cubes” with the lowest periodicity. Contact angle measurements on walls revealed enhanced surface energy anisotropy (55 mN/m max., 10 mN/m min.) causing a lengthwise spreading of the test liquid droplet, similar to cell elongation. Surface energy measurements for cubes revealed increased isotropic hydrophobicity (87° max., H2O). A critical water contact angle of ≤ 80° appears to be necessary for adequate cell adhesion. A “switch” for cell adhesion and subsequently cell growth could therefore be applied by, for example, adjusting the periodicity of hydrophobic structures. In summary cell elongation on walls and a critical surface energy level for cell adhesion could be produced for NT2/D1 and MC3T3-E1 cells by symmetrical and asymmetrical energy barrier levels. We, furthermore, propose a water-drop model providing a common physicochemical cause regarding similar cell/droplet geometries and cell adhesion on the investigated microstructures.
Collapse
|
42
|
Mantz A, Pannier AK. Biomaterial substrate modifications that influence cell-material interactions to prime cellular responses to nonviral gene delivery. Exp Biol Med (Maywood) 2019; 244:100-113. [PMID: 30621454 PMCID: PMC6405826 DOI: 10.1177/1535370218821060] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
IMPACT STATEMENT This review summarizes how biomaterial substrate modifications (e.g. chemical modifications like natural coatings, ligands, or functional side groups, and/or physical modifications such as topography or stiffness) can prime the cellular response to nonviral gene delivery (e.g. affecting integrin binding and focal adhesion formation, cytoskeletal remodeling, endocytic mechanisms, and intracellular trafficking), to aid in improving gene delivery for applications where a cell-material interface might exist (e.g. tissue engineering scaffolds, medical implants and devices, sensors and diagnostics, wound dressings).
Collapse
Affiliation(s)
- Amy Mantz
- Department of Biological Systems Engineering,
University
of Nebraska-Lincoln, Lincoln, NE 68583,
USA
| | - Angela K Pannier
- Department of Biological Systems Engineering,
University
of Nebraska-Lincoln, Lincoln, NE 68583,
USA
| |
Collapse
|
43
|
Chen X, Fan H, Deng X, Wu L, Yi T, Gu L, Zhou C, Fan Y, Zhang X. Scaffold Structural Microenvironmental Cues to Guide Tissue Regeneration in Bone Tissue Applications. NANOMATERIALS (BASEL, SWITZERLAND) 2018; 8:E960. [PMID: 30469378 PMCID: PMC6266401 DOI: 10.3390/nano8110960] [Citation(s) in RCA: 106] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 11/15/2018] [Accepted: 11/17/2018] [Indexed: 02/07/2023]
Abstract
In the process of bone regeneration, new bone formation is largely affected by physico-chemical cues in the surrounding microenvironment. Tissue cells reside in a complex scaffold physiological microenvironment. The scaffold should provide certain circumstance full of structural cues to enhance multipotent mesenchymal stem cell (MSC) differentiation, osteoblast growth, extracellular matrix (ECM) deposition, and subsequent new bone formation. This article reviewed advances in fabrication technology that enable the creation of biomaterials with well-defined pore structure and surface topography, which can be sensed by host tissue cells (esp., stem cells) and subsequently determine cell fates during differentiation. Three important cues, including scaffold pore structure (i.e., porosity and pore size), grain size, and surface topography were studied. These findings improve our understanding of how the mechanism scaffold microenvironmental cues guide bone tissue regeneration.
Collapse
Affiliation(s)
- Xuening Chen
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China.
| | - Hongyuan Fan
- Scholl of Manufacturing Science and Engineering, Sichuan University, Chengdu 610065, China.
| | - Xiaowei Deng
- Department of Civil Engineering, The University of Hongkong, Pokfulam, Hongkong 999077, China.
| | - Lina Wu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China.
| | - Tao Yi
- Scholl of Manufacturing Science and Engineering, Sichuan University, Chengdu 610065, China.
| | - Linxia Gu
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE 68588-0526, USA.
| | - Changchun Zhou
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China.
| | - Yujiang Fan
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China.
| | - Xingdong Zhang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China.
| |
Collapse
|
44
|
Zamani Y, Mohammadi J, Amoabediny G, Visscher DO, Helder MN, Zandieh-Doulabi B, Klein-Nulend J. Enhanced osteogenic activity by MC3T3-E1 pre-osteoblasts on chemically surface-modified poly(
ε
-caprolactone) 3D-printed scaffolds compared to RGD immobilized scaffolds. Biomed Mater 2018; 14:015008. [DOI: 10.1088/1748-605x/aaeb82] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
45
|
Shelobolina ES, Walker DK, Parker AE, Lust DV, Schultz JM, Dickerman GE. Inactivation of Pseudomonas aeruginosa biofilms formed under high shear stress on various hydrophilic and hydrophobic surfaces by a continuous flow of ozonated water. BIOFOULING 2018; 34:826-834. [PMID: 30311502 DOI: 10.1080/08927014.2018.1506023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 07/25/2018] [Indexed: 06/08/2023]
Abstract
The inactivation of Pseudomonas aeruginosa biofilms grown on glass under high shear stress and exposed to a range of dissolved ozone concentrations (2, 5 and 7 ppm) at 10 and 20 min was investigated. The regression equation, log reduction (biofilm) = 0.64 + 0.59×(C - 2) + 0.33×(T - 10), described the dependence of biofilm inactivation on the dissolved ozone concentration (C, ppm) and contact time (T, min). The predicted D-values were 11.1, 5.7 and 2.2 min at 2, 5 and 7 ppm, respectively. Inactivation of biofilms grown on various surfaces was tested at a single dissolved ozone concentration of 5 ppm and a single exposure time of 20 min. Biofilms grown on plastic materials showed inactivation results similar to that of biofilms on glass, while biofilms grown on ceramics were statistically significantly more difficult to inactivate, suggesting the importance of utilizing non-porous materials in industrial and clinical settings.
Collapse
Affiliation(s)
| | - Diane K Walker
- b Center for Biofilm Engineering , Montana State University , Bozeman , MT , USA
| | - Albert E Parker
- b Center for Biofilm Engineering , Montana State University , Bozeman , MT , USA
- c Department of Mathematical Sciences , Montana State University , Bozeman , MT , USA
| | - Dorian V Lust
- a NorthStar Medical Radioisotopes LLC , Madison , WI , USA
| | - Johanna M Schultz
- b Center for Biofilm Engineering , Montana State University , Bozeman , MT , USA
| | - Grace E Dickerman
- b Center for Biofilm Engineering , Montana State University , Bozeman , MT , USA
| |
Collapse
|
46
|
Kim Y, Meade SM, Chen K, Feng H, Rayyan J, Hess-Dunning A, Ereifej ES. Nano-Architectural Approaches for Improved Intracortical Interface Technologies. Front Neurosci 2018; 12:456. [PMID: 30065623 PMCID: PMC6056633 DOI: 10.3389/fnins.2018.00456] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Accepted: 06/14/2018] [Indexed: 12/19/2022] Open
Abstract
Intracortical microelectrodes (IME) are neural devices that initially were designed to function as neuroscience tools to enable researchers to understand the nervous system. Over the years, technology that aids interfacing with the nervous system has allowed the ability to treat patients with a wide range of neurological injuries and diseases. Despite the substantial success that has been demonstrated using IME in neural interface applications, these implants eventually fail due to loss of quality recording signals. Recent strategies to improve interfacing with the nervous system have been inspired by methods that mimic the native tissue. This review focusses on one strategy in particular, nano-architecture, a term we introduce that encompasses the approach of roughening the surface of the implant. Various nano-architecture approaches have been hypothesized to improve the biocompatibility of IMEs, enhance the recording quality, and increase the longevity of the implant. This review will begin by introducing IME technology and discuss the challenges facing the clinical deployment of IME technology. The biological inspiration of nano-architecture approaches will be explained as well as leading fabrication methods used to create nano-architecture and their limitations. A review of the effects of nano-architecture surfaces on neural cells will be examined, depicting the various cellular responses to these modified surfaces in both in vitro and pre-clinical models. The proposed mechanism elucidating the ability of nano-architectures to influence cellular phenotype will be considered. Finally, the frontiers of next generation nano-architecture IMEs will be identified, with perspective given on the future impact of this interfacing approach.
Collapse
Affiliation(s)
- Youjoung Kim
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Seth M. Meade
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Keying Chen
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States
| | - He Feng
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Jacob Rayyan
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Allison Hess-Dunning
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Evon S. Ereifej
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH, United States
| |
Collapse
|
47
|
Li S, Yu W, Zhang W, Zhang G, Yu L, Lu E. Evaluation of highly carbonated hydroxyapatite bioceramic implant coatings with hierarchical micro-/nanorod topography optimized for osseointegration. Int J Nanomedicine 2018; 13:3643-3659. [PMID: 29983560 PMCID: PMC6027846 DOI: 10.2147/ijn.s159989] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Background Optimal osseointegration has been recognized as a pivotal factor in determining the long-term success of biomedical implants. Materials and methods In the current study, highly carbonated hydroxyapatite (CHA) with carbonate contents of 8, 12 and 16 wt% and pure hydroxyapatite (HA) were fabricated via a novel hydrothermal method and deposited on the titanium substrates to generate corresponding CHA bioceramic coatings (designated as C8, C12 and C16, respectively) and HA bioceramic coatings (designated as C0). Results C8, C12 and C16 were endowed with nanoscale, hierarchical hybrid micro-/nanoscale and microscale surface topographies with rod-like superstructures, respectively. Compared with C0, the micro-/nanotextured CHA bioceramic coatings (C8, C12 and C16) possessed excellent surface bioactivity and biocompatibility, as well as better wettability, which mediated improved protein adsorption, giving rise to simultaneous enhancement of a biological cascade of events of rat bone-marrow-derived mesenchymal stem cells including cell adhesion, proliferation, osteogenic differentiation and, notably, the production of the pro-angiogenic growth factor, vascular endothelial growth factor-A. In particular, C12 with biomimetic hierarchical hybrid micro-/nanorod topography exhibited superior fractal property and predominant performance of protein adsorption, cell adhesion, proliferation and osteogenesis concomitant with angiogenesis. Conclusion All these results suggest that the 12 wt% CHA bioceramic coating with synergistic modification of surface chemistry and topography has great prospect for future use as implant coating to achieve optimum osseointegration for orthopedic and dental applications.
Collapse
Affiliation(s)
- Shuang Li
- Department of Stomatology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China, ; .,Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Weijun Yu
- College of Stomatology, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Weiqi Zhang
- Department of Stomatology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China, ;
| | - Guohua Zhang
- Department of Stomatology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China, ;
| | - Li Yu
- Department of Stomatology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China, ;
| | - Eryi Lu
- Department of Stomatology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China, ;
| |
Collapse
|
48
|
Gnavi S, Morano M, Fornasari BE, Riccobono C, Tonda-Turo C, Zanetti M, Ciardelli G, Gambarotta G, Perroteau I, Geuna S, Raimondo S. Combined Influence of Gelatin Fibre Topography and Growth Factors on Cultured Dorsal Root Ganglia Neurons. Anat Rec (Hoboken) 2018; 301:1668-1677. [DOI: 10.1002/ar.23846] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Revised: 01/26/2018] [Accepted: 02/12/2018] [Indexed: 12/12/2022]
Affiliation(s)
- Sara Gnavi
- Neuroscience Institute of the Cavalieri-Ottolenghi Foundation; University of Torino; Orbassano 10043 Italy
| | - Michela Morano
- Neuroscience Institute of the Cavalieri-Ottolenghi Foundation; University of Torino; Orbassano 10043 Italy
- Department of Clinical and Biological Sciences; University of Torino; Orbassano 10043 Italy
| | - Benedetta Elena Fornasari
- Neuroscience Institute of the Cavalieri-Ottolenghi Foundation; University of Torino; Orbassano 10043 Italy
- Department of Clinical and Biological Sciences; University of Torino; Orbassano 10043 Italy
| | - Claudio Riccobono
- Neuroscience Institute of the Cavalieri-Ottolenghi Foundation; University of Torino; Orbassano 10043 Italy
| | - Chiara Tonda-Turo
- Department of Mechanical and Aerospace Engineering; Politecnico of Torino; Torino 10100 Italy
| | - Marco Zanetti
- Nanostructured Interfaces and Surfaces, Department of Chemistry; University of Torino; Torino 10100 Italy
| | - Gianluca Ciardelli
- Department of Mechanical and Aerospace Engineering; Politecnico of Torino; Torino 10100 Italy
| | - Giovanna Gambarotta
- Department of Clinical and Biological Sciences; University of Torino; Orbassano 10043 Italy
| | - Isabelle Perroteau
- Department of Clinical and Biological Sciences; University of Torino; Orbassano 10043 Italy
| | - Stefano Geuna
- Neuroscience Institute of the Cavalieri-Ottolenghi Foundation; University of Torino; Orbassano 10043 Italy
- Department of Clinical and Biological Sciences; University of Torino; Orbassano 10043 Italy
| | - Stefania Raimondo
- Neuroscience Institute of the Cavalieri-Ottolenghi Foundation; University of Torino; Orbassano 10043 Italy
- Department of Clinical and Biological Sciences; University of Torino; Orbassano 10043 Italy
| |
Collapse
|
49
|
Li NB, Sun SJ, Bai HY, Xiao GY, Xu WH, Zhao JH, Chen X, Lu YP, Zhang YL. Preparation of well-distributed titania nanopillar arrays on Ti6Al4V surface by induction heating for enhancing osteogenic differentiation of stem cells. NANOTECHNOLOGY 2018; 29:045101. [PMID: 29182157 DOI: 10.1088/1361-6528/aa9daa] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Great effort has recently been devoted to the preparation of nanoscale surfaces on titanium-based implants to achieve clinically fast osteoinduction and osseointegration, which relies on the unique characteristics of the nanostructure. In this work, we used induction heating treatment (IHT) as a rapid oxidation method to fabricate a porous nanoscale oxide layer on the Ti6Al4V surface for better medical application. Well-distributed vertical nanopillars were yielded by IHT for 20-35 s on the alloy surface. The composition of the oxides contained rutile/anatase TiO2 and a small amount of Al2O3 between the TiO2 grain boundaries (GBs). This technology resulted in a reduction and subsequent increase of surface roughness of 26-32 nm when upregulating the heating time, followed by the successive enhancement of the thickness, wettability and adhesion strength of the oxidation layer to the matrix. The surface hardness also distinctly rose to 554 HV in the IHT-35 s group compared with the 350 HV of bare Ti6Al4V. The massive small-angle GBs in the bare alloy promoted the formation of nanosized oxide crystallites. The grain refinement and deformation texture reduction further improved the mechanical properties of the matrix after IHT. Moreover, in vitro experiments on a mesenchymal stem cell (BMSC) culture derived from human bone marrow for 1-7 days indicated that the nanoscale layers did not cause cytotoxicity, and facilitated cell differentiation in osteoblasts by enhancing the gene and osteogenesis-related protein expressions after 1-3 weeks of culturing. The increase of the IHT time slightly advanced the BMSC proliferation and differentiation, especially during long-term culture. Our findings provide strong evidence that IHT oxidation technology is a novel nanosurface modification technology, which is potentially promising for further clinical development.
Collapse
Affiliation(s)
- Ning-Bo Li
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Ji'nan 250061, People's Republic of China. Suzhou Institute, Shandong University, Suzhou 215123, People's Republic of China. School of Materials Science and Engineering, Shandong University, Ji'nan 250061, People's Republic of China
| | | | | | | | | | | | | | | | | |
Collapse
|