1
|
Haghgouei H, Alizadeh N. Cellulose-based potentiometric sensor array for simultaneous determination of non-steroidal anti-inflammatory drugs in human serum and saliva samples. Int J Biol Macromol 2025; 311:144026. [PMID: 40348244 DOI: 10.1016/j.ijbiomac.2025.144026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2025] [Revised: 04/16/2025] [Accepted: 05/06/2025] [Indexed: 05/14/2025]
Abstract
A cellulose based potentiometric sensor array with four selective conductive molecularly imprinted polymers (CMIPs) as sensing elements for the determination of nonsteroidal anti-inflammatory drugs (NSAIDs) (ibuprofen (IBP), diclofenac (DIC), naproxen (NAP), and salicylic acid (SA)) simultaneously in biological fluids was introduced. For that purpose, cellulose papers became chemically conductive first. Subsequently, an electrochemical method fabricated a layer based on polypyrrole as a selective recognition element for each drug on the paper's substrate. Additionally, a cellulose-based adsorbent was fabricated and utilized in electrochemically controlled solid-phase microextraction (EC-SPME) for real sample clean-up before sensor array determination. Also, factors affecting the performance of the cellulose-based EC-SPME device were optimized. In the detection process, anionic Nernstian compliance for drugs was gained at -56.1 to -59.27 mV decade-1. Good linearities were achieved within the range of 0.12-1688 μM with the determination coefficients, R2 ≥ 0.99, and the limits of detection values (LODs) were 0.05 to 0.25 μM. The effectiveness and reliability of a cellulose-based sensor array device for identifying pharmaceuticals in human serum and saliva samples were examined. Accordingly, it was discovered that the cellulose-based sensor array was a revolutionary production device for the effective, versatile, and selective determination of NSAIDs in biological fluids simultaneously.
Collapse
Affiliation(s)
- Hanieh Haghgouei
- Department of Chemistry, Faculty of Basic Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| | - Naader Alizadeh
- Department of Chemistry, Faculty of Basic Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran.
| |
Collapse
|
2
|
Robinson EEA, Fathy MA, Bühlmann P. Detection and Explanation of the Hidden Self-Discharge of Single-Walled Carbon-Nanotube Solid Contacts in Ion-Selective Electrodes. ACS Sens 2025; 10:2948-2956. [PMID: 40152660 DOI: 10.1021/acssensors.4c03702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2025]
Abstract
Solid contacts made of nonredox-active high-surface-area materials provide ion-selective electrodes comprising an ionophore-doped sensing membrane with a high capacitance. As emphasized in the literature, this minimizes changes in the measured potential that result from the minimal but unavoidable currents of real-life potentiometric measurements. However, as shown here for solid contacts made of single-walled carbon nanotubes (SWCNTs), solid contacts actively charged up over several minutes to voltages as small as ±100 mV do not hold this charge for longer than a few hours. Potential discharge occurs due to Faradaic processes and charge redistribution within the narrow confines of the SWCNT layer. The composition of the sensor membranes and atmospheric conditions have only a small impact on the kinetics of this spontaneous discharge, suggesting that redox reactions involving oxygen and the sensing membrane components do not play critical roles. Because both ion mobilities and the rate of redox reactions are expected to increase with temperature, the significant acceleration of discharge at higher temperature does not clarify whether charge redistribution or redox reactions dominate this discharge. However, contact angle measurements show that SWCNT-modified electrodes without an ion-selective membrane exhibit a substantial decrease in hydrophobicity after prolonged application of a bias potential as small as +100 mV, while application of a negative voltage had only a minor effect. This is consistent with very slow oxidation of the SWCNTs. These findings highlight the importance of optimizing the surface chemistry of high-surface-area solid contacts in view of high long-term stabilities. We propose quick charging of solid contacts to moderate potentials, followed by long-term potential monitoring under zero-current conditions, as a more thorough approach to characterize ISEs with high-surface-area solid contacts, offering insights not available with conventional chronopotentiometry measurements.
Collapse
Affiliation(s)
- Emily E A Robinson
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Mahmoud Abdelwahab Fathy
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
- Department of Chemistry, Faculty of Science, Ain Shams University, Abbasia, Cairo 11566, Egypt
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
3
|
Lenar N, Piech R, Paczosa-Bator B. Candle soot-smoked electrodes as a natural superhydrophobic material for potentiometric sensors. Talanta 2025; 285:127389. [PMID: 39693868 DOI: 10.1016/j.talanta.2024.127389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2024] [Revised: 12/10/2024] [Accepted: 12/13/2024] [Indexed: 12/20/2024]
Abstract
The application of carbon soot as a solid-contact layer in potentiometric sensor is presented. The preparation method of carbon layer from the candle is inexpensive and as short as 10 s and was optimized and described in the scope of this paper. With the use of the proposed procedure, it is possible to cover not only the glassy carbon disc electrodes, but all surfaces of various shapes and types, like foil or paper. Obtained soot layer was casted with potassium-selective membrane, for the comparison of results with other solutions presented in literature, however by changing the composition of ion-selective membrane it is possible to achieve electrodes sensitive to various cations and anions. By introducing the candle soot into the sensor, the electrical and analytical properties of electrode were significantly improved. Designed candle soot-based sensor exhibit repeatable and reversible Nernstian response towards potassium ions, low detection limit (10-6.7 M K+ ions), remarkable potential stability (drift equals to 15 μV/h) enhanced selectivity (in comparison with coated-disc electrode) and short response time. Designed sensors owe its great analytical properties to high electrical capacity (C = 343 μF) and superhydrophobic properties (proven by the high value of contact angle - 165°). Obtained sensors are insensitive to redox conditions and exhibit long lifetime. Performed tests proved that carbon layer obtained directly from the candle is appropriate material for solid-contact layer in potentiometric sensor and allows to obtain robust potentiometric sensor of competitive parameters using simple and fast procedure.
Collapse
Affiliation(s)
- Nikola Lenar
- Faculty of Materials Science and Ceramics, AGH University of Krakow, Mickiewicza 30, PL-30059, Krakow, Poland.
| | - Robert Piech
- Faculty of Materials Science and Ceramics, AGH University of Krakow, Mickiewicza 30, PL-30059, Krakow, Poland.
| | - Beata Paczosa-Bator
- Faculty of Materials Science and Ceramics, AGH University of Krakow, Mickiewicza 30, PL-30059, Krakow, Poland.
| |
Collapse
|
4
|
Zhou Y, Liang R, Qin W. Facile fabrication of anti-fouling polymeric membrane potentiometric ion sensors based on a biocide 4,5-dichloro-2- n-octyl-4-isothiazolin-3-one-containing self-adhesive waterborne polyurethane coating. Analyst 2025; 150:1103-1111. [PMID: 39980460 DOI: 10.1039/d4an01583e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2025]
Abstract
Polymeric membrane ion-selective electrodes (ISEs) are a powerful tool for ion sensing. However, their application in complicated environmental water samples is still a challenge owing to the occurrence of electrode biofouling. To address this issue, we propose a facile and effective method for enhancing the anti-biofouling properties of these sensors. A self-adhesive coating based on waterborne polyurethane and biocide 4,5-dichloro-2-n-octyl-4-isothiazolin-3-one is prepared. The anti-fouling potentiometric ion sensor can be obtained by simply drop-casting such a self-adhesive coating. The classical poly(vinyl chloride) membrane-based Ca2+-ISE is chosen as a model. Compared to the unmodified pristine Ca2+-ISE, the obtained anti-fouling sensor exhibits remarkable improved anti-fouling properties such as a much lower adhesion rate of bacteria (96.8% reduction after modification), higher anti-microbial rate and superior anti-algal properties. More importantly, the proposed potentiometric sensor displays excellent long-term response stability even when immersed in real seawater or a solution with high levels of algae for 30 days. It is anticipated that this simple and flexible approach could be extended to fabricate other anti-fouling electrochemical or optical membrane sensors. This work may lay an important foundation for development of anti-fouling chemical sensors for environmental water monitoring.
Collapse
Affiliation(s)
- Ying Zhou
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China.
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Rongning Liang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China.
| | - Wei Qin
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China.
- Laboratory for Marine Biology and Biotechnology, Qingdao Marine Science and Technology Center, Qingdao, Shandong 266237, P. R. China
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, Shandong 266071, P. R. China
| |
Collapse
|
5
|
Motshakeri M, Angoro B, Phillips ARJ, Svirskis D, Kilmartin PA, Sharma M. Advancements in Mercury-Free Electrochemical Sensors for Iron Detection: A Decade of Progress in Electrode Materials and Modifications. SENSORS (BASEL, SWITZERLAND) 2025; 25:1474. [PMID: 40096308 PMCID: PMC11902859 DOI: 10.3390/s25051474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2025] [Revised: 02/18/2025] [Accepted: 02/24/2025] [Indexed: 03/19/2025]
Abstract
Efforts to quantify iron ion concentrations across fields such as environmental, chemical, health, and food sciences have intensified over the past decade, which drives advancements in analytical methods, particularly electrochemical sensors known for their simplicity, portability, and reliability. The development of electrochemical methods using non-mercury electrodes is increasing as alternatives to environmentally unsafe mercury-based electrodes. However, detecting iron species such as Fe(II) and Fe(III) remains challenging due to their distinct chemical properties, continuous oxidation-state interconversion, presence of interfering species, and complex behavior in diverse environments and matrixes. Selective trace detection demands careful optimization of electrochemical methods, including proper electrode materials selection, electrode surface modifications, operating conditions, and sample pretreatments. This review critically evaluates advancements over the past decade in mercury-free electrode materials and surface modification strategies for iron detection. Strategies include incorporating a variety of nanomaterials, composites, conducting polymers, membranes, and iron-selective ligands to improve sensitivity, selectivity, and performance. Despite advancements, achieving ultra-low detection limits in real-world samples with minimal interference remains challenging and emphasizes the need for enhanced sample pretreatment. This review identifies challenges, knowledge gaps, and future directions and paves the way for advanced iron electrochemical sensors for environmental monitoring, health diagnostics, and analytical precision.
Collapse
Affiliation(s)
- Mahsa Motshakeri
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand; (B.A.); (D.S.)
- School of Biological Sciences, Faculty of Science, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand;
| | - Barbara Angoro
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand; (B.A.); (D.S.)
| | - Anthony R. J. Phillips
- School of Biological Sciences, Faculty of Science, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand;
- Surgical and Translational Research Center, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand
| | - Darren Svirskis
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand; (B.A.); (D.S.)
| | - Paul A. Kilmartin
- School of Chemical Sciences, Faculty of Science, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand;
| | - Manisha Sharma
- School of Pharmacy, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand; (B.A.); (D.S.)
| |
Collapse
|
6
|
Liu Y, Crespo GA, Cuartero M. Approaching to Calibration-Free Ion Detection Based on Thin Layer Coulometry with Ultrathin Ion-Selective Membranes. ACS MEASUREMENT SCIENCE AU 2025; 5:63-69. [PMID: 39991038 PMCID: PMC11843505 DOI: 10.1021/acsmeasuresciau.4c00069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2024] [Revised: 12/03/2024] [Accepted: 12/04/2024] [Indexed: 02/25/2025]
Abstract
In pursuit of calibration-free all-solid-state ion-selective electrodes (ISEs), we propose a coulometry strategy based on thin-layer samples confined adjacent to the ion-selective membrane (ISM) surface, with the system being controlled under a cathodic potential sweep. The ion-to-electron transducer in the ISE is the conducting polymer poly(3-octylthiophene) (POT), the oxidation state of which changes upon the application of a cathodic sweep and triggers the accumulation of the preferred cation in the ISM. This accumulation is provided of absolute nature (i.e., the cation concentration is totally depleted in the sample) when the capacity of the membrane encompasses the charge of the cation of interest in the sample (K+ in this case). As such, the ion exchanger content of the ISM is fixed to 18 μC, being able to accumulate a K+ concentration from the solution in the range of 5-40 μM. The charge transfer in the POT film ultimately leads to the K+ transfer at the ISM-sample interface, depleting its content in the thin-layer sample with demonstrated efficiency (∼100% at 5 and 1 mV s-1). The charge is directly proportional to the corresponding concentration via the Faraday law, constituting the core principle of the calibration-free approach. In essence, there is no need of calibrating the sensor, because the K+ concentration can be obtained from the charge by knowing the sample volume with certain precision (volume of 5 μL, with the sample thickness being 100 ± 5 μm). The conceptual innovation introduced in this Letter is accompanied by the validated calibration-free detection of K+ in five real samples, demonstrating the plausibility of the approach to contribute to the measurement science field, especially in the direction of fulfilling the gap between benchtop trials and the end users of electrochemical sensors. It is key to put efforts into calibration-free sensors to address real world applications such as point-of-care, wearable sensors for well-being, and environmental in situ monitoring, among others.
Collapse
Affiliation(s)
- Yujie Liu
- Department
of Chemistry, School of Engineering Science in Chemistry, Biochemistry
and Health, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden
| | - Gastón A. Crespo
- Department
of Chemistry, School of Engineering Science in Chemistry, Biochemistry
and Health, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden
- UCAM-SENS,
Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres
Hernandez Ros 1, 30107 Murcia, Spain
| | - María Cuartero
- Department
of Chemistry, School of Engineering Science in Chemistry, Biochemistry
and Health, KTH Royal Institute of Technology, SE-100 44 Stockholm, Sweden
- UCAM-SENS,
Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres
Hernandez Ros 1, 30107 Murcia, Spain
| |
Collapse
|
7
|
Fathy MA, Bühlmann P. Next-Generation Potentiometric Sensors: A Review of Flexible and Wearable Technologies. BIOSENSORS 2025; 15:51. [PMID: 39852102 PMCID: PMC11764208 DOI: 10.3390/bios15010051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2024] [Revised: 01/10/2025] [Accepted: 01/13/2025] [Indexed: 01/26/2025]
Abstract
In recent years, the field of wearable sensors has undergone significant evolution, emerging as a pivotal topic of research due to the capacity of such sensors to gather physiological data during various human activities. Transitioning from basic fitness trackers, these sensors are continuously being improved, with the ultimate objective to make compact, sophisticated, highly integrated, and adaptable multi-functional devices that seamlessly connect to clothing or the body, and continuously monitor bodily signals without impeding the wearer's comfort or well-being. Potentiometric sensors, leveraging a range of different solid contact materials, have emerged as a preferred choice for wearable chemical or biological sensors. Nanomaterials play a pivotal role, offering unique properties, such as high conductivity and surface-to-volume ratios. This article provides a review of recent advancements in wearable potentiometric sensors utilizing various solid contacts, with a particular emphasis on nanomaterials. These sensors are employed for precise ion concentration determinations, notably sodium, potassium, calcium, magnesium, ammonium, and chloride, in human biological fluids. This review highlights two primary applications, that is, (1) the enhancement of athletic performance by continuous monitoring of ion levels in sweat to gauge the athlete's health status, and (2) the facilitation of clinical diagnosis and preventive healthcare by monitoring the health status of patients, in particular to detect early signs of dehydration, fatigue, and muscle spasms.
Collapse
Affiliation(s)
- Mahmoud Abdelwahab Fathy
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN 55455, USA
- Department of Chemistry, Faculty of Science, Ain Shams University, Abbasia, Cairo 11566, Egypt
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN 55455, USA
| |
Collapse
|
8
|
Wang C, Guo Y, Han G, Zhou Y, Nyein HYY. Calibration-free and ready-to-use wearable electroanalytical reporting system (r-WEAR) for long-term remote monitoring of electrolytes markers. Biosens Bioelectron 2025; 267:116769. [PMID: 39260101 DOI: 10.1016/j.bios.2024.116769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2024] [Revised: 09/06/2024] [Accepted: 09/08/2024] [Indexed: 09/13/2024]
Abstract
A major bottleneck in the development of wearable ion-selective sensors is the inherent conditioning and calibration procedures at the user's end due to the signal's instability and non-uniformity. To address this challenge, we developed a strategy that integrates three interdependent materials and device engineering approaches to realize a Ready-to-use Wearable ElectroAnalytical Reporting system (r-WEAR) for reliable electrolytes monitoring. The strategy collectively utilized (1) finely-configured diffusion-limiting polymers to stabilize the electromotive force in the electrodes, (2) a uniform electrical induction in electrochemical cells to normalize the open-circuit potential (OCP), and (3) an electrical shunt to maintain the OCP across the entire sensor in the r-WEAR. The approaches jointly enable fabrication of homogeneously stable and uniform ion-selective sensors, eliminating common conditioning and calibration practices. As a result, the r-WEAR demonstrated a signal's variation down to ±1.99 mV with a signal drift of 0.5 % per hour (0.12 mV h-1) during a 12-h continuous measurement of 10 sensors and a signal drift as low as 13.3 μV h-1 during storage. On-body evaluations of the r-WEAR for four days without conditioning and re-/calibration further validated the sensor's performance in realistic settings, indicating its remarkable potential for practical usage in a user operation-free manner in wearable healthcare applications.
Collapse
Affiliation(s)
- Chaoqi Wang
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, China
| | - Yue Guo
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, China
| | - Ge Han
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, China
| | - Yifan Zhou
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, China
| | - Hnin Yin Yin Nyein
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, China.
| |
Collapse
|
9
|
Zhai J, Duan S, Luo B, Jin X, Dong H, Wang X. Classification techniques of ion selective electrode arrays in agriculture: a review. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:8068-8079. [PMID: 39543972 DOI: 10.1039/d4ay01346h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2024]
Abstract
Agriculture has a substantial demand for classification, and each agricultural product exhibits a unique ion signal. This paper summarizes the classification techniques of ion-selective electrode arrays in agriculture. Initially, data sample collection methods based on ion-selective electrode arrays are summarized. The paper then discusses the current state of classification algorithms from the perspectives of machine learning, artificial neural networks, extreme learning machines, and deep learning, along with their existing research in ion-selective electrodes and related fields. Then, the potential applications in crop and livestock growth status classification, soil classification, agricultural product quality classification, and agricultural product type classification are discussed. Ultimately, the future challenges of ion-selective electrode research are discussed from the perspectives of the sensor itself and algorithms combined with sensor arrays, which also positively impact the promotion of their application in agriculture. This work will advance the application of classification techniques combined with ion-selective electrode arrays in agriculture.
Collapse
Affiliation(s)
- Jiawei Zhai
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Department of Artificial Intelligence and Automation, Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China
- Key Laboratory of Agricultural Sensors, Ministry of Agriculture and Rural Affairs, Beijing, 100097, China
| | - Shuhao Duan
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Key Laboratory of Agricultural Sensors, Ministry of Agriculture and Rural Affairs, Beijing, 100097, China
| | - Bin Luo
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Key Laboratory of Agricultural Sensors, Ministry of Agriculture and Rural Affairs, Beijing, 100097, China
| | - Xiaotong Jin
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Key Laboratory of Agricultural Sensors, Ministry of Agriculture and Rural Affairs, Beijing, 100097, China
| | - Hongtu Dong
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Key Laboratory of Agricultural Sensors, Ministry of Agriculture and Rural Affairs, Beijing, 100097, China
| | - Xiaodong Wang
- Intelligent Equipment Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Key Laboratory of Agricultural Sensors, Ministry of Agriculture and Rural Affairs, Beijing, 100097, China
| |
Collapse
|
10
|
Toor A, Goodrich P, Anthony TL, Beckstoffer C, Jegan H, Silver WL, Arias AC. Printed Potentiometric Ammonium Sensors for Agriculture Applications. ACS OMEGA 2024; 9:47453-47460. [PMID: 39651077 PMCID: PMC11618443 DOI: 10.1021/acsomega.4c05746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 09/23/2024] [Accepted: 11/06/2024] [Indexed: 12/11/2024]
Abstract
Ammonium (NH4 +) concentration is critical to both nutrient availability and nitrogen (N) loss in soil ecosystems but can be highly variable across spatial and temporal scales. For this reason, effectively informing agricultural practices such as fertilizer management and understanding of mechanisms of soil N loss require sensor technologies to monitor ammonium concentrations in real time. Our work investigates the performance of fully printed ammonium ion-selective sensors used in diverse soil environments. Ammonium sensors consisting of a printed ammonium ion-selective electrode and a printed Ag/AgCl reference were fabricated and characterized in aqueous solutions and three different soil types (sand, peat, and clay) under the range of ion concentrations likely to be present in soil (0.01-100 mM). The response of ammonium sensors was further evaluated under variable gravimetric moisture content in the soil to reflect their reliability under field conditions. Ammonium sensors demonstrated a sensitivity of 53.6 ± 5.1 mV/decade when tested in aqueous solution, and a sensitivity of 55.7 ± 11 mV/dec, 57.5 ± 4.1 mV/dec, and 43.7 ± 4 mV/dec was measured in sand, clay, and peat soils, respectively.
Collapse
Affiliation(s)
- Anju Toor
- School
of Materials Science and Engineering, Georgia
Institute of Technology, Atlanta, Georgia 30332, United States
- Department
of Electrical Engineering and Computer Science, University of California Berkeley, Berkeley, California 94720-1770, United States
| | - Payton Goodrich
- Department
of Electrical Engineering and Computer Science, University of California Berkeley, Berkeley, California 94720-1770, United States
| | - Tyler L. Anthony
- Department
of Environmental Science Policy and Management, University of California Berkeley, Berkeley, California 94720-1770, United States
| | - Claire Beckstoffer
- Department
of Environmental Science Policy and Management, University of California Berkeley, Berkeley, California 94720-1770, United States
| | - Haeshini Jegan
- School
of Materials Science and Engineering, Georgia
Institute of Technology, Atlanta, Georgia 30332, United States
| | - Whendee L. Silver
- Department
of Environmental Science Policy and Management, University of California Berkeley, Berkeley, California 94720-1770, United States
| | - Ana Claudia Arias
- Department
of Electrical Engineering and Computer Science, University of California Berkeley, Berkeley, California 94720-1770, United States
| |
Collapse
|
11
|
Ali MA, Ataei Kachouei M. Advancing Multi-Ion Sensing with Poly-Octylthiophene: 3D-Printed Milker-Implantable Microfluidic Device. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2408314. [PMID: 39401415 DOI: 10.1002/advs.202408314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2024] [Revised: 09/28/2024] [Indexed: 12/19/2024]
Abstract
On-site rapid multi-ion sensing accelerates early identification of environmental pollution, water quality, and disease biomarkers in both livestock and humans. This study introduces a pocket-sized 3D-printed sensor, manufactured using additive manufacturing, specifically designed for detecting iron (Fe2+), nitrate (NO3 -), calcium (Ca2+), and phosphate (HPO4 2-). A unique feature of this device is its utilization of a universal ion-to-electron transducing layer made from highly redox-active poly-octylthiophene (POT), enabling an all-solid-state electrode tailored to each ion of interest. Manufactured with an extrusion-based 3D printer, the device features a periodic pattern of lateral layers (width = 80 µm), including surface wrinkles. The superhydrophobic nature of the POT prevents the accumulation of nonspecific ions at the interface between the gold and POT layers, ensuring exceptional sensor selectivity. Lithography-free, 3D-printed sensors achieve sensitivity down to 1 ppm of target ions in under a minute due to their 3D-wrinkled surface geometry. Integrated seamlessly with a microfluidic system for sample temperature stabilization, the printed sensor resides within a robust, pocket-sized 3D-printed device. This innovation integrates with milking parlors for real-time calcium detection, addressing diagnostic challenges in on-site livestock health monitoring, and has the capability to monitor water quality, soil nutrients, and human diseases.
Collapse
Affiliation(s)
- Md Azahar Ali
- School of Animal Sciences, Virginia Tech, Blacksburg, Virginia, 24061, USA
- Biological Systems Engineering, Virginia Tech, Blacksburg, Virginia, 24061, USA
| | | |
Collapse
|
12
|
Hassan SSM, Fathy MA. A novel miniaturized potentiometric electrode based on carbon nanotubes and molecularly imprinted polymer for the determination of lidocaine. Mikrochim Acta 2024; 191:744. [PMID: 39542990 PMCID: PMC11564208 DOI: 10.1007/s00604-024-06802-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2024] [Accepted: 10/22/2024] [Indexed: 11/17/2024]
Abstract
A novel miniaturized, solid-contact potentiometric screen-printed electrode was developed for highly sensitive and selective determination of lidocaine anesthetic. The electrode integrated single-walled carbon nanotubes as a solid-contact material and a molecularly imprinted polymer as a recognition sensory material. The performance characteristics of the electrode were evaluated and optimized to display a Nernstian slope of 58.92 ± 0.98 mV/decade over a linear concentration range of 4.53 × 10-7 to 6.18 × 10-3 mol/l within < 6 s. The detection limit was 7.75 × 10-8 mol/l (18.16 ng/ml) of lidocaine. The use of the molecularly imprinted polymer significantly enhanced the selectivity of the electrode, and carbon nanotubes increased the sensitivity, accuracy, and potential stability. The electrode was successfully used for determining lidocaine in pharmaceutical preparations and human urine. The results favorably compared with data obtained by liquid chromatography-tandem mass spectrometry.
Collapse
Affiliation(s)
- Saad S M Hassan
- Department of Chemistry, Faculty of Science, Ain Shams University, Abbasia, Cairo, 11566, Egypt.
| | - Mahmoud Abdelwahab Fathy
- Department of Chemistry, Faculty of Science, Ain Shams University, Abbasia, Cairo, 11566, Egypt.
| |
Collapse
|
13
|
Krivačić S, Boček Ž, Zubak M, Kojić V, Kassal P. Flexible ammonium ion-selective electrode based on inkjet-printed graphene solid contact. Talanta 2024; 279:126614. [PMID: 39094532 DOI: 10.1016/j.talanta.2024.126614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Revised: 07/05/2024] [Accepted: 07/23/2024] [Indexed: 08/04/2024]
Abstract
Miniaturization and mass-production of potentiometric sensor systems is paving the way towards distributed environmental sensing, on-body measurements and industrial process monitoring. Inkjet printing is gaining popularity as a highly adaptable and scalable production technique. Presented here is a scalable and low-cost route for flexible solid-contact ammonium ion-selective electrode fabrication by inkjet printing. Utilization of inkjet-printed melamine-intercalated graphene nanosheets as the solid-contact material significantly improved charge transport, while evading the detrimental water-layer formation. External polarization was investigated as a means of improving the inter-electrode reproducibility: the standard deviations of E0 values were reduced after electrode polarization, the linear region of the response was extended to the range 10-1-10-6 M of NH4Cl and LODs reduced to 0.88 ± 0.17 μM. Finally, we have shown that the electrodes are adequate for measurements in a complex real sample: ammonium concentration was determined in landfill leachate water, with less than 4 % deviation from the reference method.
Collapse
Affiliation(s)
- Sara Krivačić
- University of Zagreb, Faculty of Chemical Engineering & Technology, Trg Marka Marulića 19, 10000, Zagreb, Croatia
| | - Željka Boček
- University of Zagreb, Faculty of Chemical Engineering & Technology, Trg Marka Marulića 19, 10000, Zagreb, Croatia
| | - Marko Zubak
- University of Zagreb, Faculty of Chemical Engineering & Technology, Trg Marka Marulića 19, 10000, Zagreb, Croatia
| | - Vedran Kojić
- Ruđer Bošković Institute, Bijenička cesta 54, 10000, Zagreb, Croatia; HIS d.o.o., Donja Višnjica 61D, 42255, Donja Višnjica, Croatia
| | - Petar Kassal
- University of Zagreb, Faculty of Chemical Engineering & Technology, Trg Marka Marulića 19, 10000, Zagreb, Croatia.
| |
Collapse
|
14
|
Wang K, Liang R, Qin W. Surface Blocking-Based Potentiometric Biosensor for Detection of E. coli ATCC 15597 Using Phage MS2 as a Receptor. ACS Sens 2024. [PMID: 39441738 DOI: 10.1021/acssensors.4c02004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2024]
Abstract
Nowadays, using a potentiometric ion sensor to achieve detection of biological analytes is still a big challenge, since these analytes usually do not yield a measurable ion signal. To address this challenge, a simple and robust potentiometric sensing protocol based on a delayed Nernstian response is proposed for the label-free detection of biological analytes. The proposed sensor platform is composed of two layers: the surface recognition layer and the indicator-ion-selective electrode (ISE) membrane layer. It is based on a surface blocking mechanism in which the surface recognition interactions between the surface recognition element and the target can impede the diffusion of the indicator ion from the aqueous phase to the sensing membrane phase to reach the final Nernstian-response equilibrium, thus resulting in a delayed potential change. Such a potential change could be used to measure the concentration of a biological target in the sample. Thus, a sensing system was designed by using phage MS2, its host bacterium Escherichia coli ATCC 15597(abbreviated as E. coli H), and a solid-contact butyrylcholine ISE as a surface recognition element, a target, and an indicator electrode, respectively. This new concept offers a simple, sensitive, and extremely selective potentiometric method for detection of E. coli H with a detection limit of 100 CFU mL-1. It can be expected that the present approach may pave the way to using ISEs to detect various important nonionic biological targets in clinical and environmental applications.
Collapse
Affiliation(s)
- Kaikai Wang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Rongning Liang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China
| | - Wei Qin
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China
- Laboratory for Marine Biology and Biotechnology, Qingdao Marine Science and Technology Center, Qingdao, Shandong 266237, P. R. China
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, Shandong 266071, P. R. China
| |
Collapse
|
15
|
Rojas D, Torricelli D, Cuartero M, Crespo GA. 3D-Printed Transducers for Solid Contact Potentiometric Ion Sensors: Improving Reproducibility by Fabrication Automation. Anal Chem 2024; 96:15572-15580. [PMID: 39303277 PMCID: PMC11447669 DOI: 10.1021/acs.analchem.4c02098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
3D printing technology has become attractive in the development of electrochemical sensors as it offers automation in fabrication, customization on-demand, and reproducibility, among other features. Nonetheless, to date, solid contact potentiometric ion sensors have remained overlooked using this technology. Thus, the novelty of this work relies on demonstrating for the first time the usefulness of the multimaterial 3D printing approach to manufacture potentiometric ion-selective electrodes. The significance is indeed twofold. First, we discovered that by using the polyethylene terephthalate glycol (PETg) and polylactic acid-carbon black (PLA-CB) filaments together with a rational electrode design containing a well to accommodate the ion-selective membrane, a tight seal among all of the sensing materials is obtained. Importantly, this has mainly impacted the electrode-to-electrode reproducibility (ERSD0 ± 3 mV). Second, 75 ready-to-use electrodes can be printed in less than 3.5 h in a completely automated manner at a cost of ∼0.32 €/sensor. This feature may positively impact the suitability of further scaled-up production as well as the possibility of application in low-resource contexts. Overall, the presented outcomes are expected to encourage certain research directions to adopt using multimaterial 3D-printing approaches for producing highly reproducible solid contact potentiometric ion-selective electrodes, but are not restricted to them.
Collapse
Affiliation(s)
- Daniel Rojas
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
| | - Dario Torricelli
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
| | - María Cuartero
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
| | - Gastón A Crespo
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
| |
Collapse
|
16
|
Soares RRA, Milião GL, Pola CC, Jing D, Opare-Addo J, Smith E, Claussen JC, Gomes CL. Insights into solid-contact ion-selective electrodes based on laser-induced graphene: Key performance parameters for long-term and continuous measurements. Mikrochim Acta 2024; 191:615. [PMID: 39311973 DOI: 10.1007/s00604-024-06672-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2024] [Accepted: 08/26/2024] [Indexed: 10/13/2024]
Abstract
This work aims to serve as a comprehensive guide to properly characterize solid-contact ion-selective electrodes (SC-ISEs) for long-term use as they advance toward calibration-free sensors. The lack of well-defined SC-ISE performance criteria limits the ability to compare results and track progress in the field. Laser-induced graphene (LIG) is a rapid and scalable method that, by adjusting the CO2 laser parameters, can create LIG substrates with tunable surface properties, including wettability, surface chemistry, and morphology. Herein, we fabricate laser-induced graphene (LIG) solid-contact electrodes using different laser settings and subsequently convert them into ion-selective sensors using a potassium-selective membrane. We measure the aforementioned tunable surface properties and correlate them with resultant low-frequency capacitance and water layer formation in an effort to pinpoint their effects on the sensitivity (Nernstian response), reproducibility (E°' variation), and potential stability of the LIG-based SC-ISEs. More specifically, we demonstrate that the surface wettability of the LIG substrate, which can be tuned by controlling the lasing parameters, can be modified to exhibit hydrophobic (contact angle > 90°) and even highly hydrophobic surfaces (contact angle ≈ 130°) to help reduce sensor drift. Recommendations are also provided to ensure proper and robust characterization of SC-ISEs for long-term and continuous measurements. Ultimately, we believe that a comprehensive understanding of the correlation between LIG tunable surface properties and SC-ISE performance can be used to improve the electrochemical behavior and stability of SC-ISEs designed with a wide range of materials beyond LIG.
Collapse
Affiliation(s)
- Raquel R A Soares
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Gustavo L Milião
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Cícero C Pola
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA
- Department of Food Science and Human Nutrition, Iowa State University, Ames, IA, 50011, USA
| | - Dapeng Jing
- Materials Analysis and Research Laboratory, Iowa State University, Ames, IA, 50011, USA
| | - Jemima Opare-Addo
- Department of Chemistry, Iowa State University, Ames, IA, 50011, USA
| | - Emily Smith
- Department of Chemistry, Iowa State University, Ames, IA, 50011, USA
| | - Jonathan C Claussen
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA.
| | - Carmen L Gomes
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA.
| |
Collapse
|
17
|
Patrick SC, Hein R, Beer PD, Davis JJ. Non-faradaic capacitive cation sensing under flow. Chem Sci 2024:d4sc05271d. [PMID: 39263657 PMCID: PMC11382808 DOI: 10.1039/d4sc05271d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Accepted: 09/02/2024] [Indexed: 09/13/2024] Open
Abstract
The ability to continually monitor target ion species in real-time is a highly sought-after endeavour in the field of host-guest chemistry, given its direct pertinence to medical and environmental applications. Developing methodologies which support sensitive and continuous ion sensing in aqueous media, however, remains a challenge. Herein, we present a versatile and facile, proof-of-concept electrochemical sensing methodology based on non-faradaic capacitance, which can be operated continuously with high temporal resolution (≈1.4 s), in conjunction with custom-designed integrated microfluidics. The potential of this method is demonstrated for cation sensing at a chemically simple benzo-15-crown-5-based molecular film (B15C5SAM) as a representative redox-inactive, receptive interface. Detection limits as low as 4 μM are obtained for Na+ by these entirely reagentless analyses, and are additionally characterised by exceptional baseline stabilities that are able to support continuous sensing over multiple days. The platform performs well in artificial sweat across physiologically relevant spans of sodium concentration, and provides meaningful dose-dependent responses in freshwater samples. Finally, the high assay temporal resolution affords an ability to resolve both the kinetics of binding (association/dissociation) and notably characteristic fingerprints for different alkali metals which may be diagnostic of different interfacial ion binding modes.
Collapse
Affiliation(s)
- Sophie C Patrick
- Department of Chemistry, University of Oxford South Parks Road Oxford OX1 3QZ UK
| | - Robert Hein
- Department of Chemistry, University of Oxford South Parks Road Oxford OX1 3QZ UK
| | - Paul D Beer
- Department of Chemistry, University of Oxford South Parks Road Oxford OX1 3QZ UK
| | - Jason J Davis
- Department of Chemistry, University of Oxford South Parks Road Oxford OX1 3QZ UK
| |
Collapse
|
18
|
Amirghasemi F, Al-Shami A, Ushijima K, Mousavi MPS. Flexible Acetylcholine Neural Probe with a Hydrophobic Laser-Induced Graphene Electrode and a Fluorous-Phase Sensing Membrane. ACS MATERIALS LETTERS 2024; 6:4158-4167. [PMID: 39309214 PMCID: PMC11415234 DOI: 10.1021/acsmaterialslett.4c00825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/25/2024]
Abstract
This work develops the first laser-induced graphene (LIG)-based electrochemical sensor with a superhydrophobic fluorous membrane for a flexible acetylcholine (ACh) sensor. ACh regulates several physiological functions, including synaptic transmission and glandular secretion. The ACh sensing membrane is doped with a fluorophilic cation-exchanger that can selectively measure ACh based on the inherent selectivity of the fluorous phase for hydrophobic ions, such as ACh. The fluorous-phase sensor improves the selectivity for ACh over Na+ and K+ by 2 orders of magnitude (compared to traditional lipophilic membranes), thus lowering the detection limit in artificial cerebrospinal fluid (aCSF) from 331 to 0.38 μ M, thereby allowing measurement in physiologically relevant ranges of ACh. Engraving LIG under argon creates a hydrophobic surface with a 133.7° contact angle, which minimizes the formation of a water layer. The flexible solid-contact LIG fluorous sensor exhibited a slope of 59.3 mV/decade in aCSF and retained function after 20 bending cycles, thereby paving the way for studying ACh's role in memory and neurodegenerative diseases.
Collapse
Affiliation(s)
- Farbod Amirghasemi
- Alfred E. Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California 90089, United States
| | - Abdulrahman Al-Shami
- Alfred E. Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California 90089, United States
| | - Kara Ushijima
- Alfred E. Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California 90089, United States
| | - Maral P S Mousavi
- Alfred E. Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California 90089, United States
| |
Collapse
|
19
|
Chipangura Y, Komal M, Brandao VSM, Sedmak C, Choi JS, Swisher SL, Bühlmann P, Stein A. Nanoporous Carbon Materials as Solid Contacts for Microneedle Ion-Selective Sensors. ACS APPLIED MATERIALS & INTERFACES 2024; 16:44428-44439. [PMID: 39146498 DOI: 10.1021/acsami.4c07683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/17/2024]
Abstract
Continuous sensing of biomarkers, such as potassium ions or pH, in wearable patches requires miniaturization of ion-selective sensor electrodes. Such miniaturization can be achieved by using nanostructured carbon materials as solid contacts in microneedle-based ion-selective and reference electrodes. Here we compare three carbon materials as solid contacts: colloid-imprinted mesoporous (CIM) carbon microparticles with ∼24-28 nm mesopores, mesoporous carbon nanospheres with 3-9 nm mesopores, and Super P carbon black nanoparticles without internal porosity but with textural mesoporosity in particle aggregates. We compare the effects of carbon architecture and composition on specific capacitance of the material, on the ability to incorporate ion-selective membrane components in the pores, and on sensor performance. Functioning K+ and H+ ion-selective electrodes and reference electrodes were obtained with gold-coated stainless-steel microneedles using all three types of carbon. The sensors gave near-Nernstian responses in clinically relevant concentration ranges, were free of potentially detrimental water layers, and showed no response to O2. They all exhibited sufficiently low long-term potential drift values to permit calibration-free, continuous operation for close to 1 day. In spite of the different specific capacitances and pore architecture of the three types of carbon, no significant difference in potential stability for K+ ion sensing was observed between electrodes that used each material. In the observed drift values, factors other than the carbon solid contact are likely to play a role, too. However, for pH sensing, electrodes with CIM as a carbon solid contact, which had the highest specific capacitance and best access to the pores, exhibited better long-term stability than electrodes with the other carbon materials.
Collapse
Affiliation(s)
- Yevedzo Chipangura
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Maria Komal
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Vilma S M Brandao
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Christopher Sedmak
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Jung Suk Choi
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Sarah L Swisher
- Department of Electrical and Computer Engineering, University of Minnesota, 200 Union St. SE, Minneapolis, Minnesota 55455, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Andreas Stein
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
20
|
Imali DY, Perera ECJ, Kaumal MN, Dissanayake DP. Conducting polymer functionalization in search of advanced materials in ionometry: ion-selective electrodes and optodes. RSC Adv 2024; 14:25516-25548. [PMID: 39139237 PMCID: PMC11321474 DOI: 10.1039/d4ra02615b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2024] [Accepted: 08/01/2024] [Indexed: 08/15/2024] Open
Abstract
Functionalized conducting polymers (FCPs) have recently garnered attention as ion-selective sensor materials, surpassing their intrinsic counterparts due to synergistic effects that lead to enhanced electrochemical and analytical parameters. Following a brief introduction of the fundamental concepts, this article provides a comprehensive review of the recent developments in the application of FCPs in ion-selective electrodes (ISEs) and ion-selective optodes (ISOs), particularly as ion-to-electron transducers, optical transducers, and ion-selective membranes. Utilizing FCPs in these devices offers a promising avenue for detecting and measuring ions in various applications, regardless of the sample nature and composition. Research has focused on functionalizing different conducting polymers, such as polyaniline and polypyrrole, through strategies such as doping and derivatization to alter their hydrophobicity, conductance, redox capacitance, surface area, pH sensitivity, gas and light sensitivity, etc. These modifications aim to enhance performance outcomes, including potential stability/emission signal stability, reproducibility and low detection limits. The advancements have led to the transition of ISEs from conventional zero-current potentiometric ion sensing to innovative current-triggered sensing approaches, enabling calibration-free applications and emerging concepts such as opto-electro dual sensing systems. The intrinsic pH cross-response and instability of the optical signal of ISOs have been overcome through the novel optical signal transduction mechanisms facilitated by FCPs. In this review, the characteristics of materials, functionalization approaches, particular implementation strategies, specific performance outcomes and challenges faced are discussed. Consolidating dispersed information in the field, the in-depth analysis presented here is poised to drive further innovations by broadening the scope of ion-selective sensors in real-world scenarios.
Collapse
Affiliation(s)
- D Yureka Imali
- Department of Chemistry, University of Colombo Colombo 03 Sri Lanka
| | | | - M N Kaumal
- Department of Chemistry, University of Colombo Colombo 03 Sri Lanka
| | | |
Collapse
|
21
|
Salvigni L, Nayak PD, Koklu A, Arcangeli D, Uribe J, Hama A, Silva R, Hidalgo Castillo TC, Griggs S, Marks A, McCulloch I, Inal S. Reconfiguration of organic electrochemical transistors for high-accuracy potentiometric sensing. Nat Commun 2024; 15:6499. [PMID: 39090103 PMCID: PMC11294360 DOI: 10.1038/s41467-024-50792-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Accepted: 07/16/2024] [Indexed: 08/04/2024] Open
Abstract
Organic electrochemical transistors have emerged as a promising alternative to traditional 2/3 electrode setups for sensing applications, offering in-situ transduction, electrochemical amplification, and noise reduction. Several of these devices are designed to detect potentiometric-derived signals. However, potentiometric sensing should be performed under open circuit potential conditions, allowing the system to reach thermodynamic equilibrium. This criterion is not met by conventional organic electrochemical transistors, where voltages or currents are directly applied to the sensing interface, that is, the gate electrode. In this work, we introduce an organic electrochemical transistor sensing configuration called the potentiometric‑OECT (pOECT), which maintains the sensing electrode under open circuit potential conditions. The pOECT exhibits a higher response than the 2-electrode setup and offers greater accuracy, response, and stability compared to conventional organic electrochemical transistors. Additionally, it allows for the implementation of high-impedance electrodes as gate/sensing surfaces, all without compromising the overall device size.
Collapse
Affiliation(s)
- Luca Salvigni
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, KAUST, Thuwal, Saudi Arabia
| | - Prem Depan Nayak
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, KAUST, Thuwal, Saudi Arabia
| | - Anil Koklu
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, KAUST, Thuwal, Saudi Arabia
| | - Danilo Arcangeli
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, KAUST, Thuwal, Saudi Arabia
| | - Johana Uribe
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, KAUST, Thuwal, Saudi Arabia
| | - Adel Hama
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, KAUST, Thuwal, Saudi Arabia
| | - Raphaela Silva
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, KAUST, Thuwal, Saudi Arabia
| | - Tania Cecilia Hidalgo Castillo
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, KAUST, Thuwal, Saudi Arabia
| | - Sophie Griggs
- University of Oxford, Department of Chemistry, Oxford, UK
| | - Adam Marks
- University of Oxford, Department of Chemistry, Oxford, UK
| | - Iain McCulloch
- University of Oxford, Department of Chemistry, Oxford, UK
| | - Sahika Inal
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, KAUST, Thuwal, Saudi Arabia.
| |
Collapse
|
22
|
Mirabootalebi SO, Liu Y. Recent advances in nanomaterial-based solid-contact ion-selective electrodes. Analyst 2024; 149:3694-3710. [PMID: 38885067 DOI: 10.1039/d4an00334a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/20/2024]
Abstract
Solid-contact ion-selective electrodes (SC-ISEs) are advanced potentiometric sensors with great capability to detect a wide range of ions for the monitoring of industrial processes and environmental pollutants, as well as the determination of electrolytes for clinical analysis. Over the past decades, the innovative design of ion-selective electrodes (ISEs), specifically SC-ISEs, to improve potential stability and miniaturization for in situ/real-time analysis, has attracted considerable interest. Recently, the utilisation of nanomaterials was particularly prominent in SC-ISEs due to their excellent physical and chemical properties. In this article, we review the recent applications of various types of nanostructured materials that are composed of carbon, metals and polymers for the development of SC-ISEs. The challenges and opportunities in this field, along with the prospects for future applications of nanomaterials in SC-ISEs are also discussed.
Collapse
Affiliation(s)
| | - Yang Liu
- College of Science and Engineering, James Cook University, Townsville, Queensland 4811, Australia.
| |
Collapse
|
23
|
Gao L, Tian Y, Gao W, Xu G. Recent Developments and Challenges in Solid-Contact Ion-Selective Electrodes. SENSORS (BASEL, SWITZERLAND) 2024; 24:4289. [PMID: 39001071 PMCID: PMC11244314 DOI: 10.3390/s24134289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Revised: 06/15/2024] [Accepted: 06/24/2024] [Indexed: 07/16/2024]
Abstract
Solid-contact ion-selective electrodes (SC-ISEs) have the advantages of easy miniaturization, even chip integration, easy carrying, strong stability, and more favorable detection in complex environments. They have been widely used in conjunction with portable, wearable, and intelligent detection devices, as well as in on-site analysis and timely monitoring in the fields of environment, industry, and medicine. This article provides a comprehensive review of the composition of sensors based on redox capacitive and double-layer capacitive SC-ISEs, as well as the ion-electron transduction mechanisms in the solid-contact (SC) layer, particularly focusing on strategies proposed in the past three years (since 2021) for optimizing the performance of SC-ISEs. These strategies include the construction of ion-selective membranes, SC layer, and conductive substrates. Finally, the future research direction and possibilities in this field are discussed and prospected.
Collapse
Affiliation(s)
- Lili Gao
- School of Materials Science and Engineering, Shenyang Jianzhu University, Shenyang 110168, China;
| | - Ye Tian
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China
| | - Wenyue Gao
- Shandong Provincial Center for In-Situ Marine Sensors, Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China;
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, China
| |
Collapse
|
24
|
Amirghasemi F, Nejad SK, Chen R, Soleimani A, Ong V, Shroff N, Eftekhari T, Ushijima K, Ainla A, Siegel S, Mousavi MPS. LiFT (a Lithium Fiber-Based Test): An At-Home Companion Diagnostics for a Safer Lithium Therapy in Bipolar Disorder. Adv Healthc Mater 2024; 13:e2304122. [PMID: 38563494 PMCID: PMC11466011 DOI: 10.1002/adhm.202304122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 02/23/2024] [Indexed: 04/04/2024]
Abstract
This work presents LiFT (a lithium fiber-based test), a low-cost electrochemical sensor that can measure lithium in human saliva and urine with FDA-required accuracy. Lithium is used for the treatment of bipolar disorder, and has a narrow therapeutic window. Close monitoring of lithium concentration in biofluids and adjustment of drug dosage can minimize the devastating side effects. LiFT is an inexpensive, yet accurate and simple-to-operate lithium sensor for frequent at-home testing for early identification of lithium toxicity. The low cost and high accuracy of LiFT are enabled through an innovative design and the use of ubiquitous materials such as yarn and carbon black for fabrication. LiFT measures Li+ through potentiometric recognition using a lithium selective sensing membrane that is deposited on the ink-coated yarn. A detection limit of 0.97 µM is obtained with a sensitivity of 59.07±1.25 mV/decade for the Li+ sensor in deionized water. Moreover, the sodium correction extended LiFT's linear range in urine and saliva to 0.5 mM. The LiFT platform sends the test results to the patient's smartphone, which subsequently can be shared with the patient's healthcare provider to expedite diagnosis and prevention of acute lithium toxicity.
Collapse
Affiliation(s)
- Farbod Amirghasemi
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Los Angeles, 90089, CA, US
| | - Sina Khazaee Nejad
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Los Angeles, 90089, CA, US
| | - Ruitong Chen
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Los Angeles, 90089, CA, US
| | - Ali Soleimani
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Los Angeles, 90089, CA, US
| | - Victor Ong
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Los Angeles, 90089, CA, US
| | - Nika Shroff
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Los Angeles, 90089, CA, US
| | - Tanya Eftekhari
- Kern Medical Center, 1700 Mount Vernon Ave, Bakersfield, CA, 93306, US
| | - Kara Ushijima
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Los Angeles, 90089, CA, US
| | - Alar Ainla
- International Iberian Nanotechnology Laboratory, 4715-330 Braga, Portugal
| | - Steven Siegel
- Department of Psychiatry and Behavioral Sciences, Keck School of Medicine, University of Southern California, 1975 Zonal Ave, Los Angeles, 90033, CA, US
| | - Maral P. S. Mousavi
- Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Los Angeles, 90089, CA, US
| |
Collapse
|
25
|
Honig ML, Haba A, O'Leary KMF, Robinson EEA, Madungwe KV, Lin Y, McGuire C, Bühlmann P. Improvement of the Upper Detection Limit of Ionophore-Based H +-Selective Electrodes: Explanation and Elimination of Apparently Super-Nernstian Responses. Anal Chem 2024; 96:9901-9908. [PMID: 38850234 DOI: 10.1021/acs.analchem.4c00984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2024]
Abstract
The response range of an ion-selective electrode (ISE) has been described by counterion interference at the lower and Donnan failure at the upper detection limit. This approach fails when the potentiometric response at the upper detection limit exhibits an apparently super-Nernstian response, as has been reported repeatedly for H+-selective electrodes. While also observed when samples contain other anions, super-Nernstian responses at low pH are a problem in particular for samples that contain phthalate, a common component of commercial pH calibration solutions. This work shows that coextraction of H+ and a sample anion into the sensing membrane alone does not explain these super-Nernstian responses, even when membrane-internal diffusion potentials are taken into account. Instead, these super-Nernstian responses are explained by the formation of complexes between that anion and at least two protonated ionophore molecules. As demonstrated by experiments and explained with quantitative phase boundary models, the apparently super-Nernstian responses at low pH can be eliminated by restricting the molecular ratio of ionophore and ionic sites. Notably, this conclusion results in recommendations for the optimization of sensing membranes that, in some instances, will conflict with previously reported recommendations from the ionic site theory for the optimization of the lower detection limit. This mechanistic insight is key to maximizing the response range of these ionophore-based ISEs.
Collapse
Affiliation(s)
- Madeline L Honig
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| | - Ariki Haba
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| | - Katie M F O'Leary
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| | - Emily E A Robinson
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| | - Kuzivakwashe V Madungwe
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| | - Ye Lin
- Emerson Automation Solutions, 6021 Innovation Boulevard, Shakopee, Minnesota 55379, United States
| | - Chad McGuire
- Emerson Automation Solutions, 6021 Innovation Boulevard, Shakopee, Minnesota 55379, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
26
|
Davis N, Heikenfeld J, Milla C, Javey A. The challenges and promise of sweat sensing. Nat Biotechnol 2024; 42:860-871. [PMID: 38212492 DOI: 10.1038/s41587-023-02059-1] [Citation(s) in RCA: 24] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 11/07/2023] [Indexed: 01/13/2024]
Abstract
The potential of monitoring biomarkers in sweat for health-related applications has spurred rapid growth in the field of wearable sweat sensors over the past decade. Some of the key challenges have been addressed, including measuring sweat-secretion rate and collecting sufficient sample volumes for real-time, continuous molecular analysis without intense exercise. However, except for assessment of cystic fibrosis and regional nerve function, the ability to accurately measure analytes of interest and their physiological relevance to health metrics remain to be determined. Although sweat is not a crystal ball into every aspect of human health, we expect sweat measurements to continue making inroads into niche applications involving active sweating, such as hydration monitoring for athletes and physical laborers and later for medical and casual health monitoring of relevant drugs and hormones.
Collapse
Affiliation(s)
- Noelle Davis
- Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, CA, USA
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| | - Jason Heikenfeld
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA.
- Department of Electrical and Computer Engineering, University of Cincinnati, Cincinnati, OH, USA.
| | - Carlos Milla
- The Stanford Cystic Fibrosis Center, Center for Excellence in Pulmonary Biology, Stanford School of Medicine, Palo Alto, CA, USA.
| | - Ali Javey
- Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, CA, USA.
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA.
| |
Collapse
|
27
|
Li L, Hughes S, Osborne R, Wang X. Printing technologies for the fabrication of ion-selective electrodes. SENSING AND BIO-SENSING RESEARCH 2024; 44:100650. [PMID: 39916817 PMCID: PMC11800639 DOI: 10.1016/j.sbsr.2024.100650] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/09/2025] Open
Abstract
The fabrication of ion-selective electrodes (ISEs) via printing technologies such as screen-printing, inkjet printing, and 3D printing is attracting increasing attention due to the superb reproducibility and scalability of these technologies. In contrast to traditional manual casting, coating, and assembling procedures often used in research labs, printing methods are much more compatible with manufacturing processes in industry and, therefore, are easier to scale up. In this paper, we first summarized and compared the printing mechanisms and ink requirements of screen printing, inkjet printing, and 3D printing technologies. Then we present an overview of how different printing technologies can create sensor components, such as electrical contact layers, ion-to-electron transduction layers, ion sensing membranes, reference electrode membranes, insulation layers, and microfluidic/detection housings. The printing protocol, ink material, and sensor performance are highlighted for a few selected ISEs. This review concludes with a summary of the advantages and drawbacks of various printing technologies.
Collapse
Affiliation(s)
- Logan Li
- Department of Chemistry, Virginia Commonwealth University, Richmond, Virginia 23284, United States
| | - Shelby Hughes
- Department of Chemistry, Virginia Commonwealth University, Richmond, Virginia 23284, United States
| | - Reyna Osborne
- Department of Chemistry, Virginia Commonwealth University, Richmond, Virginia 23284, United States
| | - Xuewei Wang
- Department of Chemistry, Virginia Commonwealth University, Richmond, Virginia 23284, United States
| |
Collapse
|
28
|
Zhao J, Ding J, Luan F, Qin W. Chronopotentiometric sensors for antimicrobial peptide-based biosensing of Staphylococcus aureus. Mikrochim Acta 2024; 191:356. [PMID: 38811412 DOI: 10.1007/s00604-024-06410-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Accepted: 05/04/2024] [Indexed: 05/31/2024]
Abstract
Charged antimicrobial peptides can be used for direct potentiometric biosensing, but have never been explored. We report here a galvanostatically-controlled potentiometric sensor for antimicrobial peptide-based biosensing. Solid-state pulsed galvanostatic sensors that showed excellent stability under continuous galvanostatic polarization were prepared by utilizing reduced graphene oxide/poly (3,4-ethylenedioxythiophene): poly (4-styrenesulfonate) (rGO/PEDOT: PSS) as a solid contact. More importantly, the chronopotentiometric sensor can be made sensitive to antimicrobial peptides with intrinsic charge on demand via a current pulse. In this study, a positively charged antimicrobial peptide that can bind to Staphylococcus aureus with high affinity and good selectivity was designed as a model. Two arginine residues with positive charges were linked to the C-terminal of the peptide sequence to increase its potentiometric responses on the electrode. The bacteria binding-induced charge or charge density change of the antimicrobial peptide enables the direct chronopotentiometric detection of the target. Under the optimized conditions, the concentration of Staphylococcus aureus can be determined in the linear range 10-1.0 × 105 CFU mL-1 with a detection limit of 10 CFU mL-1. It is anticipated that such a chronopotentiometric sensing platform is readily adaptable to detect other bacteria by choosing the peptides.
Collapse
Affiliation(s)
- Jiarong Zhao
- College of Chemistry and Chemical Engineering, Yantai University, Yantai, 264003, People's Republic of China
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS), YICCAS, Yantai, 264003, Shandong, People's Republic of China
| | - Jiawang Ding
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS), YICCAS, Yantai, 264003, Shandong, People's Republic of China.
| | - Feng Luan
- College of Chemistry and Chemical Engineering, Yantai University, Yantai, 264003, People's Republic of China
| | - Wei Qin
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS), YICCAS, Yantai, 264003, Shandong, People's Republic of China
- Laboratory for Marine Biology and Biotechnology, Qingdao Marine Science and Technology Center, Qingdao, 266237, Shandong, People's Republic of China
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, 266071, Shandong, People's Republic of China
| |
Collapse
|
29
|
Liu S, Zhong L, Tang Y, Lai M, Wang H, Bao Y, Ma Y, Wang W, Niu L, Gan S. Graphene Oxide-Poly(vinyl alcohol) Hydrogel-Coated Solid-Contact Ion-Selective Electrodes for Wearable Sweat Potassium Ion Sensing. Anal Chem 2024; 96:8594-8603. [PMID: 38718350 DOI: 10.1021/acs.analchem.4c00609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
Solid-contact ion-selective electrodes (SC-ISEs) with ionophore-based polymer-sensitive membranes have been the major devices in wearable sweat sensors toward electrolyte analysis. However, the toxicity of ionophores in ion-selective membranes (ISMs), for example, valinomycin (K+ ion carrier), is a significant challenge, since the ISM directly contacts the skin during the tests. Herein, we report coating a hydrogel of graphene oxide-poly(vinyl alcohol) (GO-PVA) on the ISM to fabricate hydrogel-based SC-ISEs. The hydrogen bond interaction between GO sheets and PVA chains could enhance the mechanical strength through the formation of a cross-linking network. Comprehensive electrochemical tests have demonstrated that hydrogel-coated K+-SC-ISE maintains Nernstian response sensitivity, high selectivity, and anti-interference ability compared with uncoated K+-SC-ISE. A flexible hydrogel-based K+ sensing device was further fabricated with the integration of a solid-contact reference electrode, which has realized the monitoring of sweat K+ in real time. This work highlights the possibility of hydrogel coating for fabricating biocompatible wearable potentiometric sweat electrolyte sensors.
Collapse
Affiliation(s)
- Siyi Liu
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials and Devices, Key Laboratory of Optoelectronic Materials and Sensors in Guangdong Provincial Universities, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, Guangdong 510006, China
| | - Lijie Zhong
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials and Devices, Key Laboratory of Optoelectronic Materials and Sensors in Guangdong Provincial Universities, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, Guangdong 510006, China
| | - Yitian Tang
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials and Devices, Key Laboratory of Optoelectronic Materials and Sensors in Guangdong Provincial Universities, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, Guangdong 510006, China
| | - Meixue Lai
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials and Devices, Key Laboratory of Optoelectronic Materials and Sensors in Guangdong Provincial Universities, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, Guangdong 510006, China
| | - Haocheng Wang
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials and Devices, Key Laboratory of Optoelectronic Materials and Sensors in Guangdong Provincial Universities, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, Guangdong 510006, China
| | - Yu Bao
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials and Devices, Key Laboratory of Optoelectronic Materials and Sensors in Guangdong Provincial Universities, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, Guangdong 510006, China
| | - Yingming Ma
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials and Devices, Key Laboratory of Optoelectronic Materials and Sensors in Guangdong Provincial Universities, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, Guangdong 510006, China
| | - Wei Wang
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials and Devices, Key Laboratory of Optoelectronic Materials and Sensors in Guangdong Provincial Universities, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, Guangdong 510006, China
| | - Li Niu
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials and Devices, Key Laboratory of Optoelectronic Materials and Sensors in Guangdong Provincial Universities, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, Guangdong 510006, China
- School of Chemical Engineering and Technology, Sun Yat-sen University, Zhuhai, Guangdong 519082, P. R. China
| | - Shiyu Gan
- Center for Advanced Analytical Science, Guangzhou Key Laboratory of Sensing Materials and Devices, Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials and Devices, Key Laboratory of Optoelectronic Materials and Sensors in Guangdong Provincial Universities, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, Guangdong 510006, China
| |
Collapse
|
30
|
Kim M, Dong XIN, Spindler BD, Bühlmann P, Stein A. Functionalizing Carbon Substrates with a Covalently Attached Cobalt Redox Buffer for Calibration-Free Solid-Contact Ion-Selective Electrodes. Anal Chem 2024; 96:7558-7565. [PMID: 38696396 DOI: 10.1021/acs.analchem.4c00373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/04/2024]
Abstract
With a view to potentiometric sensing with minimal calibration requirements and high long-term stability, colloid-imprinted mesoporous (CIM) carbon was functionalized by the covalent attachment of a cobalt redox buffer and used as a new solid contact for ion-selective electrodes (ISEs). The CIM carbon surface was first modified by electroless grafting of a terpyridine ligand (Tpy-ph) using diazonium chemistry, followed by stepwise binding of Co(II) and an additional Tpy ligand to the grafted ligand, forming a bis(terpyridine) Co(II) complex, CIM-ph-Tpy-Co(II)-Tpy. Half a molar equivalent of ferrocenium tetrakis(3-chlorophenyl)borate was then used to partially oxidize the Co(II) complex. Electrodes prepared with this surface-attached CIM-ph-Tpy-Co(III/II)-Tpy redox buffer as a solid contact were tested as K+ sensors in combination with valinomycin as the ionophore and Dow 3140 silicone or plasticized poly(vinyl chloride) (PVC) as the matrixes for the ion-selective membrane (ISM). This solid contact is characterized by a redox capacitance of 3.26 F/g, ensuring a well-defined interfacial potential that underpins the transduction mechanism. By use of a redox couple as an internal reference element to control the phase boundary potential at the interface of the ISM and the CIM carbon solid contact, solid-contact ion-selective electrodes (SC-ISEs) with a standard deviation of E° as low as 0.3 mV for plasticized PVC ISMs and 3.5 mV for Dow 3140 silicone ISMs were obtained. Over 100 h, these SC-ISEs exhibit an emf drift of 20 μV/h for plasticized PVC ISMs and 62 μV/h for silicone ISMs. The differences in long-term stability and reproducibility between electrodes with ISMs comprising either a plasticized PVC or silicone matrix offer valuable insights into the effect of the polymeric matrix on sensor performance.
Collapse
Affiliation(s)
- Minog Kim
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455-0431, United States
| | - Xin I N Dong
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455-0431, United States
| | - Brian D Spindler
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455-0431, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455-0431, United States
| | - Andreas Stein
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455-0431, United States
| |
Collapse
|
31
|
Wang X, Liu T, Liang R, Qin W. Maintenance-free antifouling polymeric membrane potentiometric sensors based on self-polishing coatings. Analyst 2024; 149:2855-2863. [PMID: 38602369 DOI: 10.1039/d4an00351a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2024]
Abstract
Polymeric membrane ion-selective electrodes (ISEs) have been widely used in environmental monitoring. However, in complicated marine environments, marine biofouling usually becomes a sticky problem for these electrodes. Herein, for the first time, a novel maintenance-free antifouling potentiometric marine sensor based on a self-polishing coating (SPC) is proposed. The SPC is synthesized by using the seeded emulsion polymerization method based on the triisopropylsilyl methacrylate monomer as the regulator of the self-renewal rate. This coating can be simply modified onto the electrode surface by drop-casting. The silyl acrylate side groups of the obtained SPC on the sensor surface can be hydrolyzed in the marine alkaline medium. The shear movement of seawater driven by sea waves, wind, gravity, or vibration removes the leftover (fouled) brittle polymer backbone and thus the fouling marine microorganisms. As a proof-of-concept experiment, a polymeric membrane Ca2+-ISE is chosen as a model. Compared to the unmodified electrode, the SPC-coated Ca2+-ISE exhibits remarkable improved antifouling properties in terms of superior anti-adhesive abilities towards marine microorganisms, such as bacterial cells and algae and excellent long-term stability even in the presence of high levels of marine microorganisms. Since no additional manual maintenance is required for maintaining the antifouling abilities of the sensor, the proposed self-polishing sensor may lay an important foundation for construction of unattended long-term potentiometric monitoring systems in real marine environments.
Collapse
Affiliation(s)
- Xinyao Wang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China.
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Tonghao Liu
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China.
| | - Rongning Liang
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China.
| | - Wei Qin
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China.
- Laboratory for Marine Biology and Biotechnology, Qingdao Marine Science and Technology Center, Qingdao, Shandong 266237, P. R. China
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, Shandong 266071, P. R. China
| |
Collapse
|
32
|
Shahzad U, Saeed M, Marwani HM, Al-Humaidi JY, Rehman SU, Althomali RH, Awual MR, Rahman MM. Recent Progress on Potentiometric Sensor Applications Based on Nanoscale Metal Oxides: A Comprehensive Review. Crit Rev Anal Chem 2024:1-18. [PMID: 38593048 DOI: 10.1080/10408347.2024.2337876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
Electrochemical sensors have been the subject of much research and development as of late, with several publications detailing new designs boasting enhanced performance metrics. That is, without a doubt, because such sensors stand out from other analytical tools thanks to their excellent analytical characteristics, low cost, and ease of use. Their progress has shown a trend toward seeking out novel useful nano structure materials. A variety of nanostructure metal oxides have been utilized in the creation of potentiometric sensors, which are the subject of this article. For screen-printed pH sensors, metal oxides have been utilized as sensing layers due to their mixed ion-electron conductivity and as paste-ion-selective electrode components and in solid-contact electrodes. Further significant uses include solid-contact layers. All the metal oxide uses mentioned are within the purview of this article. Nanoscale metal oxides have several potential uses in the potentiometry method, and this paper summarizes such uses, including hybrid materials and single-component layers. Potentiometric sensors with outstanding analytical properties can be manufactured entirely from metal oxides. These novel sensors outperform the more traditional, conventional electrodes in terms of useful characteristics. In this review, we looked at the potentiometric analytical properties of different building solutions with various nanoscale metal oxides.
Collapse
Affiliation(s)
- Umer Shahzad
- Department of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Mohsin Saeed
- Department of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Hadi M Marwani
- Department of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia
- Center of Excellence for Advanced Materials Research (CEAMR), King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Jehan Y Al-Humaidi
- Department of Chemistry, College of Science, Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Shujah Ur Rehman
- Institute of Energy & Environmental Engineering, University of the Punjab, Lahore, Pakistan
| | - Raed H Althomali
- Department of Chemistry, College of Art and Science, Prince Sattam bin Abdulaziz University, Wadi Al-Dawasir, Saudi Arabia
| | - Md Rabiul Awual
- Western Australian School of Mines: Minerals, Energy and Chemical Engineering, Curtin University, Perth, WA, Australia
| | - Mohammed M Rahman
- Department of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia
- Center of Excellence for Advanced Materials Research (CEAMR), King Abdulaziz University, Jeddah 21589, Saudi Arabia
| |
Collapse
|
33
|
Choi KR, Honig ML, Bühlmann P. Ion-Selective Potentiometry with Plasma-Initiated Covalent Attachment of Sensing Membranes onto Inert Polymeric Substrates and Carbon Solid Contacts. Anal Chem 2024; 96:4702-4708. [PMID: 38451778 DOI: 10.1021/acs.analchem.4c00204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2024]
Abstract
The physical delamination of the sensing membrane from underlying electrode bodies and electron conductors limits sensor lifetimes and long-term monitoring with ion-selective electrodes (ISEs). To address this problem, we developed two plasma-initiated graft polymerization methods that attach ionophore-doped polymethacrylate sensing membranes covalently to high-surface-area carbons that serve as the conducting solid contact as well as to polypropylene, poly(ethylene-co-tetrafluoroethylene), and polyurethane as the inert polymeric electrode body materials. The first strategy consists of depositing the precursor solution for the preparation of the sensing membranes onto the platform substrates with the solid contact carbon, followed by exposure to an argon plasma, which results in surface-grafting of the in situ polymerized sensing membrane. Using the second strategy, the polymeric platform substrate is pretreated with argon plasma and subsequently exposed to ambient oxygen, forming hydroperoxide groups on the surface. Those functionalities are then used for the initiation of photoinitiated graft polymerization of the sensing membrane. Attenuated total reflection-Fourier transform infrared spectroscopy, water contact angle measurements, and delamination tests confirm the covalent attachment of the in situ polymerized sensing membranes onto the polymeric substrates. Using membrane precursor solutions comprising, in addition to decyl methacrylate and a cross-linker, also 2-(diisopropylamino)ethyl methacrylate as a covalently attachable H+ ionophore and tetrakis(pentafluorophenyl)borate as ionic sites, both plasma-based fabrication methods produced electrodes that responded to pH in a Nernstian fashion, with the high selectivity expected for ionophore-based ISEs.
Collapse
Affiliation(s)
- Kwangrok R Choi
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Madeline L Honig
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
34
|
Stelmach E, Kalisz J, Wagner B, Maksymiuk K, Michalska A. Nanofiber Ion-Selective Membrane-Coated Carbon Paper All-Solid-State Sensors: One Stone, Two Birds. Anal Chem 2024; 96:3253-3258. [PMID: 38359329 PMCID: PMC10902807 DOI: 10.1021/acs.analchem.3c04764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
Potentiometric sensors with nanostructural ion-selective membranes were prepared and tested. Electrospun nanofiber mats were applied in novel all-solid-state sensors, using carbon paper as an electronically conducting support. For the sake of simplicity, application of a solid contact layer was avoided, and redox-active impurities naturally present in the carbon paper have proven to be effective as ion-to-electron transducers. Application of a nanostructural ion-selective membrane requires an innovative approach to combine the receptor layer with the support. The nanofiber mat portion was fused with carbon paper in a hot-melt process. Applying temperature close to 120 °C for a short time (3 s) allowed binding the nanostructural ion-selective membrane with carbon paper, without significant changes in the nanofiber structure. This process was conveniently performed together with the lamination of the carbon paper support. The thus obtained, potentially disposable sensors were characterized as exhibiting highly reproducible potential readings in time as well as between sensors belonging to the same batch. The benefits of the application of nanostructural ion-selective membranes include shorter equilibration time, lower detection limit, and significantly lower material consumption. However, the nanostructural membrane is characterized by a higher electrical resistance, which is attributed to higher porosity.
Collapse
Affiliation(s)
- Emilia Stelmach
- Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
| | - Justyna Kalisz
- Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
| | - Barbara Wagner
- Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
| | - Krzysztof Maksymiuk
- Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
| | - Agata Michalska
- Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
| |
Collapse
|
35
|
Choi KR, Honig ML, Bühlmann P. Covalently attached ionophores extend the working range of potentiometric pH sensors with poly(decyl methacrylate) sensing membranes. Analyst 2024; 149:1132-1140. [PMID: 38205703 DOI: 10.1039/d3an02047a] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2024]
Abstract
The pH working range of solid-contact ion-selective electrodes (ISEs) with plasticizer-free poly(decyl methacrylate) sensing membranes is shown to be expanded by covalent attachment of H+ ionophores to the polymeric membrane matrix. In situ photopolymerization not only incorporates the ionophores into the polymer backbone, but at the same time also attaches the sensing membranes covalently to the underlying inert polymer and nanographite solid contact, minimizing sensor drift and preventing failure by membrane delamination. A new pyridine-based H+ ionophore, 3-(pyridine-3-yl)propyl methacrylate, has lower basicity than trialkylamine ionophores and expands the upper detection limit. This reduces in particular the interference from hydrogen phthalate, which is a common component of commercial pH buffers. Moreover, the lower detection limit is improved by replacing the CH2CH2 spacer of previously reported dialkylaminoethyl methacrylates with a (CH2)10 spacer, which increases its basicity. Notably, for the more basic and highly cation-selective ionophore 10-(diisopropylamino)decyl methacrylate, the extent of counterion interference from hydrogen phthalate shifted the upper detection limit to lower pH by nearly one pH unit when the crosslinker concentration was decreased.
Collapse
Affiliation(s)
- Kwangrok R Choi
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN 55455, USA.
| | - Madeline L Honig
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN 55455, USA.
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN 55455, USA.
| |
Collapse
|
36
|
Chipangura YE, Spindler BD, Bühlmann P, Stein A. Design Criteria for Nanostructured Carbon Materials as Solid Contacts for Ion-Selective Sensors. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2309778. [PMID: 38105339 DOI: 10.1002/adma.202309778] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 12/05/2023] [Indexed: 12/19/2023]
Abstract
The ability to miniaturize ion-selective sensors that enable microsensor arrays and wearable sensor patches for ion detection in environmental or biological samples requires all-solid-state sensors with solid contacts for transduction of an ion activity into an electrical signal. Nanostructured carbon materials function as effective solid contacts for this purpose. They can also contribute to improved potential signal stability, reducing the need for frequent sensor calibration. In this Perspective, the structural features of various carbon-based solid contacts described in the literature and their respective abilities to reduce potential drift during long-term, continuous measurements are compared. These carbon materials include nanoporous carbons with various architectures, carbon nanotubes, carbon black, graphene, and graphite-based solid contacts. The effects of accessibility of ionophores, ionic sites, and other components of an ion-selective membrane to the internal or external carbon surfaces are discussed, because this impacts double-layer capacitance and potential drift. The effects of carbon composition on water-layer formation are also considered, which is another contributor to potential drift during long-term measurements. Recommendations regarding the selection of solid contacts and considerations for their characterization and testing in solid-contact ion-selective electrodes are provided.
Collapse
Affiliation(s)
- Yevedzo E Chipangura
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN, 55454, USA
| | - Brian D Spindler
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN, 55454, USA
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN, 55454, USA
| | - Andreas Stein
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, MN, 55454, USA
| |
Collapse
|
37
|
Lai M, Zhong L, Liu S, Tang Y, Han T, Deng H, Bao Y, Ma Y, Wang W, Niu L, Gan S. Carbon fiber-based multichannel solid-contact potentiometric ion sensors for real-time sweat electrolyte monitoring. Anal Chim Acta 2024; 1287:342046. [PMID: 38182362 DOI: 10.1016/j.aca.2023.342046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 11/16/2023] [Accepted: 11/17/2023] [Indexed: 01/07/2024]
Abstract
Solid-contact ion-selective electrodes (SC-ISEs) feature miniaturization and integration that have gained extensive attention in non-invasive wearable sweat electrolyte sensors. The state-of-the-art wearable SC-ISEs mainly use polyethylene terephthalate, gold and carbon nanotube fibers as flexible substrates but suffer from uncomfortableness, high cost and biotoxicity. Herein, we report carbon fiber-based SC-ISEs to construct a four-channel wearable potentiometric sensor for sweat electrolytes monitoring (Na+/K+/pH/Cl-). The carbon fibers were extracted from commercial cloth, of which the starting point is addressing the cost and reproducibility issues for flexible SC-ISEs. The bare carbon fiber electrodes exhibited reversible voltammetric and stable impedance performances. Further fabricated SC-ISEs based on corresponding ion-selective membranes disclosed Nernstian sensitivity and anti-interface ability toward both ions and organic species in sweat. Significantly, these carbon fiber-based SC-ISEs revealed high reproducibility of standard potentials between normal and bending states. Finally, a textile-based sensor was integrated with a solid-contact reference electrode, which realized on-body sweat electrolytes analysis. The results displayed high accuracy compared with ex-situ tests by ion chromatography. This work highlights carbon fiber-based multichannel wearable potentiometric ion sensors with low cost, biocompatibility and reproducibility.
Collapse
Affiliation(s)
- Meixue Lai
- Guangdong Engineering Technology Research Center for Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Lijie Zhong
- Guangdong Engineering Technology Research Center for Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China.
| | - Siyi Liu
- Guangdong Engineering Technology Research Center for Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Yitian Tang
- Guangdong Engineering Technology Research Center for Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Tingting Han
- Guangdong Engineering Technology Research Center for Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Huali Deng
- Guangdong Engineering Technology Research Center for Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Yu Bao
- Guangdong Engineering Technology Research Center for Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Yingming Ma
- Guangdong Engineering Technology Research Center for Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Wei Wang
- Guangdong Engineering Technology Research Center for Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China
| | - Li Niu
- Guangdong Engineering Technology Research Center for Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China; School of Chemical Engineering and Technology, Sun Yat-sen University, Zhuhai, 519082, PR China
| | - Shiyu Gan
- Guangdong Engineering Technology Research Center for Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, 510006, PR China.
| |
Collapse
|
38
|
Rousseau CR, Chipangura YE, Stein A, Bühlmann P. Effect of Ion Identity on Capacitance and Ion-to-Electron Transduction in Ion-Selective Electrodes with Nanographite and Carbon Nanotube Solid Contacts. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:1785-1792. [PMID: 38198594 DOI: 10.1021/acs.langmuir.3c03027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2024]
Abstract
The use of large surface area carbon materials as transducers in solid-contact ion-selective electrodes (ISEs) has become widespread. Desirable qualities of ISEs, such as a small long-term drift, have been associated with a high capacitance that arises from the formation of an electrical double layer at the interface of the large surface area carbon material and the ion-selective membrane. The capacitive properties of these ISEs have been observed using a variety of techniques, but the effects of the ions present in the ion-selective membrane on the measured value of the capacitance have not been studied in detail. Here, it is shown that changes in the size and concentration of the ions in the ion-selective membrane as well as the polarity of the polymeric matrix result in capacitances that can vary by up to several hundred percent. These data illustrate that the interpretation of comparatively small differences in capacitance for different types of solid contacts is not meaningful unless the composition of the ion-selective membrane is taken into account.
Collapse
Affiliation(s)
- Celeste R Rousseau
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Yevedzo E Chipangura
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Andreas Stein
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
39
|
Huang Y, Afolabi MA, Gan L, Liu S, Chen Y. MXene-Coated Ion-Selective Electrode Sensors for Highly Stable and Selective Lithium Dynamics Monitoring. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:1359-1368. [PMID: 38079615 PMCID: PMC10795166 DOI: 10.1021/acs.est.3c06235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 11/14/2023] [Accepted: 11/15/2023] [Indexed: 01/17/2024]
Abstract
Lithium holds immense significance in propelling sustainable energy and environmental systems forward. However, existing sensors used for lithium monitoring encounter issues concerning their selectivity and long-term durability. Addressing these challenges is crucial to ensure accurate and reliable lithium measurements during the lithium recovery processes. In response to these concerns, this study proposes a novel approach involving the use of an MXene composite membrane with incorporated poly(sodium 4-styrenesulfonate) (PSS) as an antibiofouling layer on the Li+ ion selective electrode (ISE) sensors. The resulting MXene-PSS Li+ ISE sensor demonstrates exceptional electrochemical performance, showcasing a superior slope (59.42 mV/dec), lower detection limit (10-7.2 M), quicker response time (∼10 s), higher selectivity to Na+ (-2.37) and K+ (-2.54), and reduced impedance (106.9 kΩ) when compared to conventional Li+ ISE sensors. These improvements are attributed to the unique electronic conductivity and layered structure of the MXene-PSS nanosheet coating layer. In addition, the study exhibits the long-term accuracy and durability of the MXene-PSS Li+ ISE sensor by subjecting it to real wastewater testing for 14 days, resulting in sensor reading errors of less than 10% when compared to laboratory validation results. This research highlights the great potential of MXene nanosheet coatings in advancing sensor technology, particularly in challenging applications, such as detecting emerging contaminants and developing implantable biosensors. The findings offer promising prospects for future advancements in sensor technology, particularly in the context of sustainable energy and environmental monitoring.
Collapse
Affiliation(s)
| | | | - Lan Gan
- School of Civil and Environmental
Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Su Liu
- School of Civil and Environmental
Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Yongsheng Chen
- School of Civil and Environmental
Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
40
|
Özbek O, Altunoluk OC, Isildak Ö. Surface characterization and electroanalytical applications of the newly developed copper(II)-selective potentiometric sensor. ANAL SCI 2024; 40:141-149. [PMID: 37821773 DOI: 10.1007/s44211-023-00436-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 09/25/2023] [Indexed: 10/13/2023]
Abstract
In this work, we developed a new copper(II)-selective potentiometric sensor and investigated its surface with scanning electron microscopy (SEM). Besides the surface images of the sensors conditioned in copper(II) solutions, energy-dispersive X-ray (EDX) and mapping studies were carried out. According to the results obtained, it was determined that copper(II) ions adhered to the porous areas on the sensor surface, and that Cu2+ ions showed a wide distribution on the sensor surface in mapping studies. The new sensor had a Nernstian response of 29.3 ± 0.5 mV/decade in the concentration range of 1.0 × 10-1-1.0 × 10-5 M and a low detection limit of 8.56 × 10-6 M. The proposed sensor had fast response time (< 10 s), wide pH working range (5.0-10.0), good repeatability and stability. Finally, the sensor performed the determination of copper(II) ions in various water samples with very high recoveries (96.0-102.0%).
Collapse
Affiliation(s)
- Oguz Özbek
- Science and Technology, Application and Research Center, Zonguldak Bülent Ecevit University, 67600, Zonguldak, Turkey.
| | - Onur Cem Altunoluk
- Department of Chemistry, Faculty of Science and Arts, Tokat Gaziosmanpaşa University, 60250, Tokat, Turkey
| | - Ömer Isildak
- Department of Chemistry, Faculty of Science and Arts, Tokat Gaziosmanpaşa University, 60250, Tokat, Turkey
| |
Collapse
|
41
|
Mou J, Ding J, Qin W. Modern Potentiometric Biosensing Based on Non-Equilibrium Measurement Techniques. Chemistry 2023; 29:e202302647. [PMID: 37733874 DOI: 10.1002/chem.202302647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 09/20/2023] [Accepted: 09/21/2023] [Indexed: 09/23/2023]
Abstract
Modern potentiometric sensors based on polymeric membrane ion-selective electrodes (ISEs) have achieved new breakthroughs in sensitivity, selectivity, and stability and have extended applications in environmental surveillance, medical diagnostics, and industrial analysis. Moreover, nonclassical potentiometry shows promise for many applications and opens up new opportunities for potentiometric biosensing. Here, we aim to provide a concept to summarize advances over the past decade in the development of potentiometric biosensors with polymeric membrane ISEs. This Concept article articulates sensing mechanisms based on non-equilibrium measurement techniques. In particular, we emphasize new trends in potentiometric biosensing based on attractive dynamic approaches. Representative examples are selected to illustrate key applications under zero-current conditions and stimulus-controlled modes. More importantly, fruitful information obtained from non-equilibrium measurements with dynamic responses can be useful for artificial intelligence (AI). The combination of ISEs with advanced AI techniques for effective data processing is also discussed. We hope that this Concept will illustrate the great possibilities offered by non-equilibrium measurement techniques and AI in potentiometric biosensing and encourage further innovations in this exciting field.
Collapse
Affiliation(s)
- Junsong Mou
- CAS Key Laboratory of Coastal Environmental Processes, and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS), Yantai, 264003, Shandong, P. R. China
- University of Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Jiawang Ding
- CAS Key Laboratory of Coastal Environmental Processes, and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS), Yantai, 264003, Shandong, P. R. China
- Qingdao National Laboratory for Marine Science and Technology, Qingdao 266237, Shandong (P. R. China), Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, 266071, Shandong, P. R. China
| | - Wei Qin
- CAS Key Laboratory of Coastal Environmental Processes, and Ecological Remediation, Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS), Yantai, 264003, Shandong, P. R. China
- Qingdao National Laboratory for Marine Science and Technology, Qingdao 266237, Shandong (P. R. China), Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, 266071, Shandong, P. R. China
| |
Collapse
|
42
|
Lenar N, Piech R, Wardak C, Paczosa-Bator B. Application of Metal Oxide Nanoparticles in the Field of Potentiometric Sensors: A Review. MEMBRANES 2023; 13:876. [PMID: 37999362 PMCID: PMC10672869 DOI: 10.3390/membranes13110876] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 10/26/2023] [Accepted: 11/04/2023] [Indexed: 11/25/2023]
Abstract
Recently, there has been rapid development of electrochemical sensors, and there have been numerous reports in the literature that describe new constructions with improved performance parameters. Undoubtedly, this is due to the fact that those sensors are characterized by very good analytical parameters, and at the same time, they are cheap and easy to use, which distinguishes them from other analytical tools. One of the trends observed in their development is the search for new functional materials. This review focuses on potentiometric sensors designed with the use of various metal oxides. Metal oxides, because of their remarkable properties including high electrical capacity and mixed ion-electron conductivity, have found applications as both sensing layers (e.g., of screen-printing pH sensors) or solid-contact layers and paste components in solid-contact and paste-ion-selective electrodes. All the mentioned applications of metal oxides are described in the scope of the paper. This paper presents a survey on the use of metal oxides in the field of the potentiometry method as both single-component layers and as a component of hybrid materials. Metal oxides are allowed to obtain potentiometric sensors of all-solid-state construction characterized by remarkable analytical parameters. These new types of sensors exhibit properties that are competitive with those of the commonly used conventional electrodes. Different construction solutions and various metal oxides were compared in the scope of this review based on their analytical parameters.
Collapse
Affiliation(s)
- Nikola Lenar
- Faculty of Materials Science and Ceramics, AGH University of Krakow, Mickiewicza 30, PL-30059 Krakow, Poland; (N.L.)
| | - Robert Piech
- Faculty of Materials Science and Ceramics, AGH University of Krakow, Mickiewicza 30, PL-30059 Krakow, Poland; (N.L.)
| | - Cecylia Wardak
- Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Square 3, PL-20031 Lublin, Poland;
| | - Beata Paczosa-Bator
- Faculty of Materials Science and Ceramics, AGH University of Krakow, Mickiewicza 30, PL-30059 Krakow, Poland; (N.L.)
| |
Collapse
|
43
|
Wiorek A, Cuartero M, Crespo GA. Selective Deionization of Thin-Layer Samples Using Tandem Carbon Nanotubes-Polymeric Membranes. Anal Chem 2023; 95:15681-15689. [PMID: 37815334 PMCID: PMC10603610 DOI: 10.1021/acs.analchem.3c02965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Accepted: 09/06/2023] [Indexed: 10/11/2023]
Abstract
Herein, we investigate the selective deionization (i.e., the removal of ions) in thin-layer samples (<100 μm in thickness) using carbon nanotubes (CNTs) covered with an ionophore-based ion-selective membrane (ISM), resulting in a CNT-ISM tandem actuator. The concept of selective deionization is based on a recent discovery by our group ( Anal. Chem. 2022, 94, 21, 7455-7459), where the activation of the CNT-ISM architecture is conceived on a mild potential step that charges the CNTs to ultimately generate the depletion of ions in a thin-layer sample. The role of the ISM is to selectively facilitate the transport of only one ion species to the CNT lattice. To estimate the deionization efficiency of such a process, a potentiometric sensor is placed less than 100 μm away from the CNT-ISM tandem, inside a microfluidic cell. This configuration helped to reveal that the selective uptake of ions increases with the capacitance of the CNTs and that the ISM requires a certain ion-exchanger capacity, but this does not further affect its efficiency. The versatility of the concept is demonstrated by comparing the selective uptake of five different ions (H+, Li+, Na+, K+, and Ca2+), suggesting the possibility to remove any cation from a sample by simply changing the ionophore in the ISM. Furthermore, ISMs based on two ionophores proved to achieve the simultaneous and selective deionization of two ion species using the same actuator. Importantly, the relative uptake between the two ions was found to be governed by the ion-ionophore binding constants, with the most strongly bound ion being favored over other ions. The CNT-ISM actuator concept is expected to contribute to the analytical sensing field in the sense that ionic interferents influencing the analytical signal can selectively be removed from samples to lower traditional limits of detection.
Collapse
Affiliation(s)
- Alexander Wiorek
- Department
of Chemistry, School of Engineering Science in Chemistry, Biochemistry
and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
| | - Maria Cuartero
- Department
of Chemistry, School of Engineering Science in Chemistry, Biochemistry
and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
- UCAM-SENS, Universidad
Católica San Antonio de Murcia,
UCAM HiTech, Avda. Andres
Hernandez Ros 1, 30107 Murcia, Spain
| | - Gastón A. Crespo
- Department
of Chemistry, School of Engineering Science in Chemistry, Biochemistry
and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
- UCAM-SENS, Universidad
Católica San Antonio de Murcia,
UCAM HiTech, Avda. Andres
Hernandez Ros 1, 30107 Murcia, Spain
| |
Collapse
|
44
|
Spindler BD, Graf KI, Dong XIN, Kim M, Chen XV, Bühlmann P, Stein A. Influence of the Composition of Plasticizer-Free Silicone-Based Ion-Selective Membranes on Signal Stability in Aqueous and Blood Plasma Samples. Anal Chem 2023; 95:12419-12426. [PMID: 37552138 DOI: 10.1021/acs.analchem.3c02074] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/09/2023]
Abstract
Solid-contact ion-selective electrodes (SC-ISEs) in direct long-term contact with physiological samples must be biocompatible and resistant to biofouling, but most wearable SC-ISEs proposed to date contain plasticized poly(vinyl chloride) (PVC) membranes, which have poor biocompatibility. Silicones are a promising alternative to plasticized PVC because of their excellent biocompatibility, but little work has been done to study the relationship between silicone composition and ISE performance. To address this, we prepared and tested K+ SC-ISEs with colloid-imprinted mesoporous (CIM) carbon as the solid contact and three different condensation-cured silicones: a custom silicone prepared in-house (Silicone 1), a commercial silicone (Dow 3140, Silicone 2), and a commercial fluorosilicone (Dow 730, Fluorosilicone 1). SC-ISEs prepared with each of these polymers and the ionophore valinomycin and added ionic sites exhibited Nernstian responses, excellent selectivities, and signal drifts as low as 3 μV/h in 1 mM KCl solution. All ISEs maintained Nernstian response slopes and had only very slightly worsened selectivities after 41 h exposure to porcine plasma (log KK,Na values of -4.56, -4.58, and -4.49, to -4.04, -4.00, and -3.90 for Silicone 1, Silicone 2, and Fluorosilicone 1, respectively), confirming that these sensors retain the high selectivity that makes them suitable for use in physiological samples. When immersed in porcine plasma, the SC-ISEs exhibited emf drifts that were still fairly low but notably larger than when measurements were performed in pure water. Interestingly, despite the very similar structures of these matrix polymers, SC-ISEs prepared with Silicone 2 showed lower drift in porcine blood plasma (-55 μV/h, over 41 h) compared to Silicone 1 (-495 μV/h) or Fluorosilicone 1 (-297 μV/h).
Collapse
Affiliation(s)
- Brian D Spindler
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Katerina I Graf
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Xin I N Dong
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Minog Kim
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Xin V Chen
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| | - Andreas Stein
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55454, United States
| |
Collapse
|
45
|
Teekayupak K, Lomae A, Agir I, Chuaypen N, Dissayabutra T, Henry CS, Chailapakul O, Ozer T, Ruecha N. Large-scale fabrication of ion-selective electrodes for simultaneous detection of Na +, K +, and Ca 2+ in biofluids using a smartphone-based potentiometric sensing platform. Mikrochim Acta 2023; 190:237. [PMID: 37222781 DOI: 10.1007/s00604-023-05818-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 04/25/2023] [Indexed: 05/25/2023]
Abstract
A significant bottleneck exists for mass-production of ion-selective electrodes despite recent developments in manufacturing technologies. Here, we present a fully-automated system for large-scale production of ISEs. Three materials, including polyvinyl chloride, polyethylene terephthalate and polyimide, were used as substrates for fabricating ion-selective electrodes (ISEs) using stencil printing, screen-printing and laser engraving, respectively. We compared sensitivities of the ISEs to determine the best material for the fabrication process of the ISEs. The electrode surfaces were modified with various carbon nanomaterials including multi-walled carbon nanotubes, graphene, carbon black, and their mixed suspensions as the intermediate layer to enhance sensitivities of the electrodes. An automated 3D-printed robot was used for the drop-cast procedure during ISE fabrication to eliminate manual steps. The sensor array was optimized, and the detection limits were 10-5 M, 10-5 M and 10-4 M for detection of K+, Na+ and Ca2+ ions, respectively. The sensor array integrated with a portable wireless potentiometer was used to detect K+, Na+ and Ca2+ in real urine and simulated sweat samples and results obtained were in agreement with ICP-OES with good recoveries. The developed sensing platform offers low-cost detection of electrolytes for point-of-care applications.
Collapse
Affiliation(s)
- Kanyapat Teekayupak
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Atchara Lomae
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Ismail Agir
- Department of Bioengineering, Faculty of Engineering and Natural Sciences, Istanbul Medeniyet University, Istanbul, 34700, Türkiye
| | - Natthaya Chuaypen
- Metabolic Disease in Gastrointestinal and Urinary System Research Unit, Department of Biochemistry, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Thasinas Dissayabutra
- Metabolic Disease in Gastrointestinal and Urinary System Research Unit, Department of Biochemistry, Faculty of Medicine, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Charles S Henry
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Bangkok, 10330, Thailand
- School of Biomedical Engineering, Department of Chemistry, Colorado State University, Fort Collins, CO, 80523, USA
| | - Orawon Chailapakul
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
| | - Tugba Ozer
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Bangkok, 10330, Thailand.
- Department of Bioengineering, Faculty of Chemical-Metallurgical Engineering, Yildiz Technical University, Istanbul, 34220, Türkiye.
- Health Biotechnology Joint Research and Application Center of Excellence, Esenler, Istanbul , 34220, Türkiye.
| | - Nipapan Ruecha
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand.
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Bangkok, 10330, Thailand.
| |
Collapse
|
46
|
Liu T, Liang R, Qin W. Anti-fouling TiO 2-Coated Polymeric Membrane Ion-Selective Electrodes with Photocatalytic Self-Cleaning Properties. Anal Chem 2023; 95:6577-6585. [PMID: 37052412 DOI: 10.1021/acs.analchem.2c05514] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/14/2023]
Abstract
Nowadays, using a polymeric membrane ion-selective electrode (ISE) to achieve reliable ion sensing in complex samples remains challenging because of electrode fouling. To address this challenge, we describe a polymeric membrane ISE with excellent anti-fouling and self-cleaning properties based on surface covalent modification of an anatase TiO2 coating. Under ultraviolet illumination, the reactive oxygen species produced by photocatalytic TiO2 can not only kill microorganisms but also degrade organic foulants into carbon dioxide and water, and a formed superhydrophilic film can effectively prevent the adsorption of foulants, thus inhibiting the occurrence of biofouling and organic fouling of the sensors. More importantly, residual foulants could be fully self-cleaned through the flow of water droplets. By using Ca2+-ISE as a model, an anti-fouling polymeric membrane potentiometric sensor has been developed. Compared to the unmodified electrode, the TiO2-coated Ca2+-ISE exhibits remarkably improved anti-biofouling properties with a low bacterial adhesion rate of 4.74% and a high inhibition rate of 96.62%. In addition, the proposed electrode displays unique properties of anti-organic dye fouling and a superior self-cleaning ability even after soaking in a concentrated bacterial suspension of 109 CFU mL-1 for 60 days. The present approach can be extended to improve the fouling resistance of other electrochemical or optical membrane sensors and is promising for the construction of contamination-free sensors.
Collapse
Affiliation(s)
- Tonghao Liu
- School of Chemistry and Chemical Engineering, Yantai University, Yantai, Shandong 264005, P. R. China
| | - Rongning Liang
- School of Chemistry and Chemical Engineering, Yantai University, Yantai, Shandong 264005, P. R. China
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai Institute of Coastal Zone Research (YIC), Yantai, Shandong 264003, P. R. China
| | - Wei Qin
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Chinese Academy of Sciences (CAS); Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai Institute of Coastal Zone Research (YIC), Yantai, Shandong 264003, P. R. China
- Laboratory for Marine Biology and Biotechnology, Qingdao National Laboratory for Marine Science and Technology, Shandong 266237, P. R. China
- Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, Shandong, 266071, P. R. China
| |
Collapse
|
47
|
Dong XIN, Spindler BD, Kim M, Stein A, Bühlmann P. Spontaneous Mesoporosity-Driven Sequestration of Ionic Liquids from Silicone-Based Reference Electrode Membranes. ACS Sens 2023; 8:1774-1781. [PMID: 37043696 DOI: 10.1021/acssensors.3c00085] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/14/2023]
Abstract
Nanopore-driven sequestration of ionic liquids from a silicone membrane is presented, a phenomenon that has not been reported previously. Reference electrodes with ionic liquid doped polydimethylsiloxane (PDMS) reference membranes and colloid-imprinted mesoporous carbon (CIM) as solid contact are not functional unless special attention is paid to the porosity of the solid contact. In the fabrication of such reference electrodes, a solution of a hydroxyl-terminated silicone oligomer, ionic liquid, cross-linking reagent, and polymerization catalyst is deposited on top of the carbon layer, rapidly filling the pores of the CIM carbon. The catalyzed polymerization curing of the silicone quickly results in cross-linking of the hydroxyl-terminated polydimethylsiloxane oligomers, forming structures that are too large to penetrate the CIM carbon pores. Therefore, as solvent evaporation from the top of freshly prepared membranes drives the diffusional transport of solvent toward that membrane surface, the solvent molecules that leave the CIM carbon pores can only be replaced by the ionic liquid. This depletes the ionic liquid in the reference membrane that overlies the CIM carbon solid contact and increases the membrane resistance by up to 3 orders of magnitude, rendering the devices dysfunctional. This problem can be avoided by presaturating the CIM carbon with ionic liquid prior to the deposition of the solution that contains the silicone oligomers and ionic liquid. Alternatively, a high amount of ionic liquid can be added into the membrane solution to account for the size-selective sequestration of ionic liquid into the carbon pores. Either way, a wide variety of ionic liquids can be used to prepare PDMS-based reference electrodes with CIM carbon as a solid contact. A similar depletion of the K+ ionophore BME-44 from ion-selective silicone membranes was observed too, highlighting that the depletion of active ingredients from polymeric ion-selective and reference membranes due to interactions with high surface area solid contacts may be a more common phenomenon that so far has been overlooked.
Collapse
Affiliation(s)
- Xin I N Dong
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Brian D Spindler
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Minog Kim
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Andreas Stein
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant St. SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
48
|
Kozma J, Papp S, Gyurcsányi RE. Highly hydrophobic TEMPO-functionalized conducting copolymers for solid-contact ion-selective electrodes. Bioelectrochemistry 2023; 150:108352. [PMID: 36563456 DOI: 10.1016/j.bioelechem.2022.108352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 12/09/2022] [Accepted: 12/10/2022] [Indexed: 12/23/2022]
Abstract
Solid-contact ion-selective electrodes (SCISEs) emerged as the best electrode embodiment for miniaturized, wearable and disposable sensors for ion/electrolyte measurements in body fluids. The commercialization of inexpensive single-use "calibration-free" electrodes requires large scale manufacturing of electrodes with reproducible calibration parameters, e.g. E0. This is perhaps the most important shortcoming of SCISEs, beside the many advantages over their conventional liquid-contact counterparts. However, adjusting the E0 value for optimal potential stability is challenging for all state-of-the-art solid-contact materials, which may combine several types of transducing mechanism (e.g. capacitive and redox materials or their combination) for enhanced potential stability and analytical performance. Therefore, here we introduce for the first time the galvanostatic intermittent titration technique (GITT) to determine the best preadjusment potential. The proof of concept is shown for a novel type of solid-contact based on the copolymerization of 3,4-ethylenedioxythiophene with perfluorinated alkyl side chain (EDOTF) and (2,2,6,6-Tetramethylpiperidin-1-yl)oxyl modified 3,4-ethylenedioxythiophene (EDOT-TEMPO). Such materials that are compliant with local electrodeposition and provide multiple functionalities, i.e. high hydrophobicity by the perfluorinated alkyl side chain, electron-to-ion transduction by the conducting polymer (EDOT) backbone and the confinement of well-defined redox couple (TEMPO), are expected to prevail as solid-contacts.
Collapse
Affiliation(s)
- József Kozma
- Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Műegyetem rkp. 3, H-1111 Budapest, Hungary; MTA-BME Lendület Chemical Nanosensors Research Group, Műegyetem rkp. 3, H-1111 Budapest, Hungary
| | - Soma Papp
- Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Műegyetem rkp. 3, H-1111 Budapest, Hungary; MTA-BME Lendület Chemical Nanosensors Research Group, Műegyetem rkp. 3, H-1111 Budapest, Hungary
| | - Róbert E Gyurcsányi
- Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Műegyetem rkp. 3, H-1111 Budapest, Hungary; MTA-BME Lendület Chemical Nanosensors Research Group, Műegyetem rkp. 3, H-1111 Budapest, Hungary; MTA-BME Computation Driven Chemistry Research Group, Műegyetem rkp. 3, H-1111 Budapest, Hungary.
| |
Collapse
|
49
|
Liu Y, Wang X, Zeng X, Waterhouse GIN, Jiang X, Zhang Z, Yu L. Antifouling improvement in Pb 2+ ion selective electrodes by using an environmentally friendly capsaicin derivative. Talanta 2023; 258:124436. [PMID: 36940573 DOI: 10.1016/j.talanta.2023.124436] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 02/21/2023] [Accepted: 03/07/2023] [Indexed: 03/16/2023]
Abstract
Biofouling is a critical issue for ion selective electrodes (ISE) in complex aqueous systems, seriously compromising the analytical performance of the electrodes (i.e., stability, sensitivity, and lifetime). Herein, an antifouling solid lead ion selective electrode (GC/PANI-PFOA/Pb2+-PISM) was successfully prepared by adding propyl 2-(acrylamidomethyl)-3,4,5-trihydroxy benzoate (PAMTB), an environmentally friendly capsaicin derivative, into the ion-selective membrane (ISM). The presence of PAMTB caused no loss in the detection performance of GC/PANI-PFOA/Pb2+-PISM (e.g., detection limit (1.9 × 10-7 M), response slope (28.5 ± 0.8 mV/decade), the response time (20 s), stability (8.6 ± 2.9 μV/s), selectivity and no water layer), whilst imparting an excellent antifouling effect with an antibacterial rate of 98.1% when the content of PAMTB in the ISM was 2.5 wt%. Further, GC/PANI-PFOA/Pb2+-PISM maintained stable antifouling properties, excellent potential response, and stability even after soaking in a high-concentration bacterial suspension for 7 days.
Collapse
Affiliation(s)
- Yanhua Liu
- Frontiers Science Center for Deep Ocean Multispheres and Earth System, and Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao, 266100, China; Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, 266100, China
| | - Xuan Wang
- Frontiers Science Center for Deep Ocean Multispheres and Earth System, and Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao, 266100, China; Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, 266100, China
| | - Xianghua Zeng
- Frontiers Science Center for Deep Ocean Multispheres and Earth System, and Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao, 266100, China; Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, 266100, China
| | | | - Xiaohui Jiang
- Frontiers Science Center for Deep Ocean Multispheres and Earth System, and Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao, 266100, China; Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, 266100, China
| | - Zhiming Zhang
- Frontiers Science Center for Deep Ocean Multispheres and Earth System, and Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao, 266100, China; Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, 266100, China; Sanya Oceanographic Institution, Ocean University of China, Sanya, 572024, China.
| | - Liangmin Yu
- Frontiers Science Center for Deep Ocean Multispheres and Earth System, and Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao, 266100, China; Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, 266100, China; Sanya Oceanographic Institution, Ocean University of China, Sanya, 572024, China.
| |
Collapse
|
50
|
Zhang W, Li J, Qin W. Solid-contact polymeric membrane ion-selective electrodes using a covalent organic framework@reduced graphene oxide composite as ion-to-electron transducer. Talanta 2023; 258:124444. [PMID: 36934662 DOI: 10.1016/j.talanta.2023.124444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 03/05/2023] [Accepted: 03/09/2023] [Indexed: 03/16/2023]
Abstract
A solid-contact ion-selective electrode (SC-ISE) based on a covalent organic framework@reduced graphene oxide (rGO) composite is proposed. The composite can be synthesized through the polycondensation of 1,3,5-triformylphloroglucinol (TFP) and 2,6-diaminoanthraquinone (DAAQ) on the rGO nanosheets, which shows high capacitance and good redox-active properties. By applying Cd2+-ISE as a model, the electrode exhibits a Nernstian slope of 29.7 ± 0.4 mV/decade in the activity range of 1.0 × 10-7 - 7.9 × 10-4 M and the limit of detection is 6.8 × 10-8 M. Particularly, the electrode based on DAAQ-TFP@rGO exhibits a low potential drift of 1.2 ± 0.2 μV/h over 70 h due to the large capacitance of 2.0 mF. Moreover, the DAAQ-TFP@rGO-based Cd2+-ISE shows good reproducibility and the standard deviations of the standard potentials for single batch and batch-to-batch are 0.28 (n = 4) and 0.30 mV (n = 4), respectively. The developed SC-Cd2+-ISE is not disturbed by light or gas and no aqueous layer occurs between the sensing membrane and DAAQ-TFP@rGO layer. The DAAQ-TFP@rGO composite is highly promising for construction of calibration-free SC-ISEs.
Collapse
Affiliation(s)
- Wenting Zhang
- College of Chemistry and Chemical Engineering, Yantai University, Yantai, Shandong, 264005, PR China; CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS), Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong, 264003, PR China
| | - Jinghui Li
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS), Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong, 264003, PR China.
| | - Wei Qin
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS), Shandong Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong, 264003, PR China; Qingdao National Laboratory for Marine Science and Technology, Qingdao, Shandong, 266237, PR China; Center for Ocean Mega-Science, Chinese Academy of Sciences, Qingdao, Shandong, 266071, PR China.
| |
Collapse
|