1
|
Gao Y, Han L, Li J, Lu X, Wang P, Du S, Zhang Y, Cai TJ, Liu QJ, Lyu Y. Establishment and verification of the dose-effect curve of dicentric chromosomes by semi-automatic analysis of human peripheral blood irradiated by X-ray in vitro. Int J Radiat Biol 2025; 101:590-597. [PMID: 40293422 DOI: 10.1080/09553002.2025.2494549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2024] [Revised: 02/28/2025] [Accepted: 04/02/2025] [Indexed: 04/30/2025]
Abstract
OBJECTIVE To establish and validate a dose-response curve for dicentric chromosomes (DC) induced by X-rays in human peripheral blood in vitro using semi-automated scoring. METHODS Peripheral blood samples were collected from three healthy individuals and exposed to X-ray doses of 0, 0.25, 0.5, 0.75, 1, 2, 3, 4, and 5 Gy at a dose rate of 1.158 Gy/min. Dicentric chromosomes in metaphase were scored both full- and semi-automatically, and a dose-response curve was generated with CABAS software based on dicentric yields. Dose estimations were then performed for 12 biodosimetry standard samples and one sample from a patient with X-ray-induced skin injury. RESULTS Dicentric yields increased with X-ray doses from 0 to 5 Gy (r = 0.943, P < 0.01). The dose-response association followed a linear-quadratic model: Y = 0.0002 (± 0.0001) + 0.0379 (± 0.0032) × D + 0.0253 (± 0.0014) × D2 (R2 = 0.998, P < 0.01), where Y represents dicentric yields and D is the dose. The estimated dose for 12 validation samples aligned closely with actual doses. The estimated whole-body average absorbed dose for the patient was 0.73 Gy, with observed DC over-dispersion suggesting partial body exposure. By using the Dolphin model, this dose was refined to 2.22 Gy and estimated irradiated body volume was 35.94%, consistent with clinical diagnosis. CONCLUSIONS The dose-response curve developed using semi-automated scoring offer a reliable and efficient approach for dose estimation and clinical diagnosis in nuclear radiation emergencies. It could also support retrospective biodosimetry of partial-body, non-uniform radiation exposure.
Collapse
Affiliation(s)
- Yu Gao
- Henan Key Laboratory of Medicine on Radiobiology and Epidemiology, Third People's Hospital of Henan Province (Henan Occupational Disease Hospital), Zhengzhou, China
| | - Lin Han
- Henan Key Laboratory of Medicine on Radiobiology and Epidemiology, Third People's Hospital of Henan Province (Henan Occupational Disease Hospital), Zhengzhou, China
| | - Jie Li
- Henan Key Laboratory of Medicine on Radiobiology and Epidemiology, Third People's Hospital of Henan Province (Henan Occupational Disease Hospital), Zhengzhou, China
| | - Xue Lu
- Chinese Center for Disease Control and Prevention, China CDC Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Beijing, China
| | - Ping Wang
- Henan Key Laboratory of Medicine on Radiobiology and Epidemiology, Third People's Hospital of Henan Province (Henan Occupational Disease Hospital), Zhengzhou, China
| | - Shasha Du
- Henan Key Laboratory of Medicine on Radiobiology and Epidemiology, Third People's Hospital of Henan Province (Henan Occupational Disease Hospital), Zhengzhou, China
| | - Yunfei Zhang
- Henan Key Laboratory of Medicine on Radiobiology and Epidemiology, Third People's Hospital of Henan Province (Henan Occupational Disease Hospital), Zhengzhou, China
| | - Tian-Jing Cai
- Chinese Center for Disease Control and Prevention, China CDC Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Beijing, China
| | - Qing-Jie Liu
- Chinese Center for Disease Control and Prevention, China CDC Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection, Beijing, China
| | - Yumin Lyu
- Henan Key Laboratory of Medicine on Radiobiology and Epidemiology, Third People's Hospital of Henan Province (Henan Occupational Disease Hospital), Zhengzhou, China
| |
Collapse
|
2
|
Wilkins RC, Beaton-Green LA. Development of high-throughput systems for biodosimetry. RADIATION PROTECTION DOSIMETRY 2023; 199:1477-1484. [PMID: 37721060 PMCID: PMC10720693 DOI: 10.1093/rpd/ncad060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 01/24/2023] [Accepted: 02/08/2023] [Indexed: 09/19/2023]
Abstract
Biomarkers for ionising radiation exposure have great utility in scenarios where there has been a potential exposure and physical dosimetry is missing or in dispute, such as for occupational and accidental exposures. Biomarkers that respond as a function of dose are particularly useful as biodosemeters to determine the dose of radiation to which an individual has been exposed. These dose measurements can also be used in medical scenarios to track doses from medical exposures and even have the potential to identify an individual's response to radiation exposure that could help tailor treatments. The measurement of biomarkers of exposure in medicine and for accidents, where a larger number of samples would be required, is limited by the throughput of analysis (i.e. the number of samples that could be processed and analysed), particularly for microscope-based methods, which tend to be labour-intensive. Rapid analysis in an emergency scenario, such as a large-scale accident, would provide dose estimates to medical practitioners, allowing timely administration of the appropriate medical countermeasures to help mitigate the effects of radiation exposure. In order to improve sample throughput for biomarker analysis, much effort has been devoted to automating the process from sample preparation through automated image analysis. This paper will focus mainly on biological endpoints traditionally analysed by microscopy, specifically dicentric chromosomes, micronuclei and gamma-H2AX. These endpoints provide examples where sample throughput has been improved through automated image acquisition, analysis of images acquired by microscopy, as well as methods that have been developed for analysis using imaging flow cytometry.
Collapse
Affiliation(s)
- Ruth C Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa K1A 1C1, Canada
| | - Lindsay A Beaton-Green
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa K1A 1C1, Canada
| |
Collapse
|
3
|
Shuryak I, Nemzow L, Bacon BA, Taveras M, Wu X, Deoli N, Ponnaiya B, Garty G, Brenner DJ, Turner HC. Machine learning approach for quantitative biodosimetry of partial-body or total-body radiation exposures by combining radiation-responsive biomarkers. Sci Rep 2023; 13:949. [PMID: 36653416 PMCID: PMC9849198 DOI: 10.1038/s41598-023-28130-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Accepted: 01/13/2023] [Indexed: 01/19/2023] Open
Abstract
During a large-scale radiological event such as an improvised nuclear device detonation, many survivors will be shielded from radiation by environmental objects, and experience only partial-body irradiation (PBI), which has different consequences, compared with total-body irradiation (TBI). In this study, we tested the hypothesis that applying machine learning to a combination of radiation-responsive biomarkers (ACTN1, DDB2, FDXR) and B and T cell counts will quantify and distinguish between PBI and TBI exposures. Adult C57BL/6 mice of both sexes were exposed to 0, 2.0-2.5 or 5.0 Gy of half-body PBI or TBI. The random forest (RF) algorithm trained on ½ of the data reconstructed the radiation dose on the remaining testing portion of the data with mean absolute error of 0.749 Gy and reconstructed the product of dose and exposure status (defined as 1.0 × Dose for TBI and 0.5 × Dose for PBI) with MAE of 0.472 Gy. Among irradiated samples, PBI could be distinguished from TBI: ROC curve AUC = 0.944 (95% CI: 0.844-1.0). Mouse sex did not significantly affect dose reconstruction. These results support the hypothesis that combinations of protein biomarkers and blood cell counts can complement existing methods for biodosimetry of PBI and TBI exposures.
Collapse
Affiliation(s)
- Igor Shuryak
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA.
| | - Leah Nemzow
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA
| | - Bezalel A Bacon
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA
| | - Maria Taveras
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA
| | - Xuefeng Wu
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA
| | - Naresh Deoli
- Radiological Research Accelerator Facility, Columbia University Irving Medical Center, Irvington, NY, USA
| | - Brian Ponnaiya
- Radiological Research Accelerator Facility, Columbia University Irving Medical Center, Irvington, NY, USA
| | - Guy Garty
- Radiological Research Accelerator Facility, Columbia University Irving Medical Center, Irvington, NY, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA
| | - Helen C Turner
- Center for Radiological Research, Columbia University Irving Medical Center, 630 West 168th street, VC-11-234/5, New York, NY, 10032, USA
| |
Collapse
|
4
|
Bucher M, Weiss T, Endesfelder D, Trompier F, Ristic Y, Kunert P, Schlattl H, Giussani A, Oestreicher U. Dose Variations Using an X-Ray Cabinet to Establish in vitro Dose-Response Curves for Biological Dosimetry Assays. Front Public Health 2022; 10:903509. [PMID: 35655448 PMCID: PMC9152255 DOI: 10.3389/fpubh.2022.903509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 04/25/2022] [Indexed: 11/13/2022] Open
Abstract
In biological dosimetry, dose-response curves are essential for reliable retrospective dose estimation of individual exposure in case of a radiation accident. Therefore, blood samples are irradiated in vitro and evaluated based on the applied assay. Accurate physical dosimetry of the irradiation performance is a critical part of the experimental procedure and is influenced by the experimental setup, especially when X-ray cabinets are used. The aim of this study was to investigate variations and pitfalls associated with the experimental setups used to establish calibration curves in biological dosimetry with X-ray cabinets. In this study, irradiation was performed with an X-ray source (195 kV, 10 mA, 0.5 mm Cu filter, dose rate 0.52 Gy/min, 1st and 2nd half-value layer = 1.01 and 1.76 mm Cu, respectively, average energy 86.9 keV). Blood collection tubes were irradiated with a dose of 1 Gy in vertical or horizontal orientation in the center of the beam area with or without usage of an additional fan heater. To evaluate the influence of the setups, physical dose measurements using thermoluminescence dosimeters, electron paramagnetic resonance dosimetry and ionization chamber as well as biological effects, quantified by dicentric chromosomes and micronuclei, were compared. This study revealed that the orientation of the sample tubes (vertical vs. horizontal) had a significant effect on the radiation dose with a variation of -41% up to +49% and contributed to a dose gradient of up to 870 mGy inside the vertical tubes due to the size of the sample tubes and the associated differences in the distance to the focal point of the tube. The number of dicentric chromosomes and micronuclei differed by ~30% between both orientations. An additional fan heater had no consistent impact. Therefore, dosimetric monitoring of experimental irradiation setups is mandatory prior to the establishment of calibration curves in biological dosimetry. Careful consideration of the experimental setup in collaboration with physicists is required to ensure traceability and reproducibility of irradiation conditions, to correlate the radiation dose and the number of aberrations correctly and to avoid systematical bias influencing the dose estimation in the frame of biological dosimetry.
Collapse
Affiliation(s)
- Martin Bucher
- Department of Effects and Risks of Ionizing and Non-Ionizing Radiation, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Tina Weiss
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - David Endesfelder
- Department of Effects and Risks of Ionizing and Non-Ionizing Radiation, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Francois Trompier
- Department of External Dosimetry, Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
| | - Yoann Ristic
- Department of External Dosimetry, Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
| | - Patrizia Kunert
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Helmut Schlattl
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Augusto Giussani
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Ursula Oestreicher
- Department of Effects and Risks of Ionizing and Non-Ionizing Radiation, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| |
Collapse
|
5
|
Gregoire E, Barquinero JF, Gruel G, Benadjaoud M, Martinez JS, Beinke C, Balajee A, Beukes P, Blakely WF, Dominguez I, Duy PN, Gil OM, Güçlü I, Guogyte K, Hadjidekova SP, Hadjidekova V, Hande P, Jang S, Lumniczky K, Meschini R, Milic M, Montoro A, Moquet J, Moreno M, Norton FN, Oestreicher U, Pajic J, Sabatier L, Sommer S, Testa A, Terzoudi G, Valente M, Venkatachalam P, Vral A, Wilkins RC, Wojcik A, Zafiropoulos D, Kulka U. RENEB Inter-Laboratory comparison 2017: limits and pitfalls of ILCs. Int J Radiat Biol 2021; 97:888-905. [PMID: 33970757 DOI: 10.1080/09553002.2021.1928782] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 04/01/2021] [Accepted: 05/06/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE In case of a mass-casualty radiological event, there would be a need for networking to overcome surge limitations and to quickly obtain homogeneous results (reported aberration frequencies or estimated doses) among biodosimetry laboratories. These results must be consistent within such network. Inter-laboratory comparisons (ILCs) are widely accepted to achieve this homogeneity. At the European level, a great effort has been made to harmonize biological dosimetry laboratories, notably during the MULTIBIODOSE and RENEB projects. In order to continue the harmonization efforts, the RENEB consortium launched this intercomparison which is larger than the RENEB network, as it involves 38 laboratories from 21 countries. In this ILC all steps of the process were monitored, from blood shipment to dose estimation. This exercise also aimed to evaluate the statistical tools used to compare laboratory performance. MATERIALS AND METHODS Blood samples were irradiated at three different doses, 1.8, 0.4 and 0 Gy (samples A, C and B) with 4-MV X-rays at 0.5 Gy min-1, and sent to the participant laboratories. Each laboratory was requested to blindly analyze 500 cells per sample and to report the observed frequency of dicentric chromosomes per metaphase and the corresponding estimated dose. RESULTS This ILC demonstrates that blood samples can be successfully distributed among laboratories worldwide to perform biological dosimetry in case of a mass casualty event. Having achieved a substantial harmonization in multiple areas among the RENEB laboratories issues were identified with the available statistical tools, which are not capable to advantageously exploit the richness of results of a large ILCs. Even though Z- and U-tests are accepted methods for biodosimetry ILCs, setting the number of analyzed metaphases to 500 and establishing a tests' common threshold for all studied doses is inappropriate for evaluating laboratory performance. Another problem highlighted by this ILC is the issue of the dose-effect curve diversity. It clearly appears that, despite the initial advantage of including the scoring specificities of each laboratory, the lack of defined criteria for assessing the robustness of each laboratory's curve is a disadvantage for the 'one curve per laboratory' model. CONCLUSIONS Based on our study, it seems relevant to develop tools better adapted to the collection and processing of results produced by the participant laboratories. We are confident that, after an initial harmonization phase reached by the RENEB laboratories, a new step toward a better optimization of the laboratory networks in biological dosimetry and associated ILC is on the way.
Collapse
Affiliation(s)
- Eric Gregoire
- Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France
| | | | - Gaetan Gruel
- Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France
| | | | - Juan S Martinez
- Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France
| | - Christina Beinke
- Bundeswehr Institute of Radiobiology affiliated to the University of Ulm, Munich, Germany
| | - Adayabalam Balajee
- Oak Ridge Institute for Science and Education (ORISE), Oak Ridge, TN, USA
| | | | - William F Blakely
- Armed Forces Radiobiology Research Institute, Uniformed Service University of the Health, Sciences, Bethesda, MD, USA
| | | | - Pham Ngoc Duy
- Center of Biotechnology, Nuclear Research Institute, Dalat city, Vietnam
| | - Octávia Monteiro Gil
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Bobadela-LRS, Portugal
| | - Inci Güçlü
- Turkish Atomic Energy Authority, Cekmece Nuclear Research and Training Center, Radiobiology Unit Yarımburgaz, Istanbul, Turkey
| | | | | | | | - Prakash Hande
- Department of Physiology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | | | - Katalin Lumniczky
- National Research Institute for Radiobiology & Radiohygiene, Budapest, Hungary
| | | | | | - Alegria Montoro
- Fundación para la Investigación del Hospital Universitario LA FE de la Comunidad Valenciana, Valencia, Spain
| | - Jayne Moquet
- Public Health England, Centre for Radiation Chemical and Environmental Hazards, Chilton, UK
| | - Mercedes Moreno
- Servicio Madrileño de Salud - Hospital General Universitario Gregorio Marañón, Madrid, Spain
| | - Farrah N Norton
- Radiobiology & Health, Canadian Nuclear Laboratories, Chalk River, Canada
| | - Ursula Oestreicher
- Federal Office for Radiation Protection (BfS), Oberschleissheim, Germany
| | - Jelena Pajic
- Serbian Institute of Occupational Health, Radiation Protection Center, Belgrade, Serbia
| | - Laure Sabatier
- PROCyTOX, Commissariat à l'Energie Atomique et aux Energies Alternatives, Fontenay aux-Roses, France and Université Paris-Saclay, France
| | - Sylwester Sommer
- Institute of Nuclear Chemistry and Technology (INCT), Warsaw, Poland
| | - Antonella Testa
- Agenzia Nazionale per le Nuove Tecnologie, L´Energia e lo Sviluppo Economico Sostenibile, Rome, Italy
| | - Georgia Terzoudi
- National Center for Scientific Research "Demokritos", NCSR"D", Athens, Greece
| | | | | | - Anne Vral
- Radiobiology Research Unit, Gent University, Gent, Belgium
| | | | - Andrzej Wojcik
- Institute Molecular Biosciences, Stockholm University, Stockholm, Sweden
| | | | - Ulrike Kulka
- Federal Office for Radiation Protection (BfS), Oberschleissheim, Germany
| |
Collapse
|
6
|
Bryant J, White L, Coen N, Shields L, McClean B, Meade AD, Lyng FM, Howe O. MicroRNA Analysis of ATM-Deficient Cells Indicate PTEN and CCDN1 as Potential Biomarkers of Radiation Response. Radiat Res 2020; 193:520-530. [PMID: 32216710 DOI: 10.1667/rr15462.1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Accepted: 03/06/2020] [Indexed: 11/03/2022]
Abstract
Genetic and epigenetic profile changes associated with individual radiation sensitivity are well documented and have led to enhanced understanding of the mechanisms of the radiation-induced DNA damage response. However, the search continues to identify reliable biomarkers of individual radiation sensitivity. Herein, we report on a multi-biomarker approach using traditional cytogenetic biomarkers, DNA damage biomarkers and transcriptional microRNA (miR) biomarkers coupled with their potential gene targets to identify radiosensitivity in ataxia-telangiectasia mutated (ATM)-deficient lymphoblastoid cell lines (LCL); ATM-proficient cell lines were used as controls. Cells were 0.05 and 0.5 Gy irradiated, using a linear accelerator, with sham-irradiated cells as controls. At 1 h postirradiation, cells were fixed for γ-H2AX analysis as a measurement of DNA damage, and cytogenetic analysis using the G2 chromosomal sensitivity assay, G-banding and FISH techniques. RNA was also isolated for genetic profiling by microRNA (miR) and RT-PCR analysis. A panel of 752 miR were analyzed, and potential target genes, phosphatase and tensin homolog (PTEN) and cyclin D1 (CCND1), were measured. The cytogenetic assays revealed that although the control cell line had functional cell cycle checkpoints, the radiosensitivity of the control and AT cell lines were similar. Analysis of DNA damage in all cell lines, including an additional control cell line, showed elevated γ-H2AX levels for only one AT cell line. Of the 752 miR analyzed, eight miR were upregulated, and six miR were downregulated in the AT cells compared to the control. Upregulated miR-152-3p, miR-24-5p and miR-92-15p and all downregulated miR were indicated as modulators of PTEN and CCDN1. Further measurement of both genes validated their potential role as radiation-response biomarkers. The multi-biomarker approach not only revealed potential candidates for radiation response, but provided additional mechanistic insights into the response in AT-deficient cells.
Collapse
Affiliation(s)
- Jane Bryant
- Radiation and Environmental Science Centre (RESC), FOCAS Research Institute
| | - Lisa White
- Radiation and Environmental Science Centre (RESC), FOCAS Research Institute.,School of Biological and Health Sciences, Technological University Dublin, City Campus, Dublin 8, Ireland
| | - Natasha Coen
- Department of Clinical Genetics, Division of Cytogenetics, Our Lady's Children's Hospital, Crumlin, Dublin 12, Ireland
| | - Laura Shields
- Medical Physics Department, St Luke's Radiation Oncology Centre, Rathgar, Dublin 6, Ireland
| | - Brendan McClean
- Medical Physics Department, St Luke's Radiation Oncology Centre, Rathgar, Dublin 6, Ireland
| | - Aidan D Meade
- Radiation and Environmental Science Centre (RESC), FOCAS Research Institute.,School of Physics & Clinical & Optometric Sciences, Technological University Dublin, City Campus, Dublin 8, Ireland
| | - Fiona M Lyng
- Radiation and Environmental Science Centre (RESC), FOCAS Research Institute.,School of Physics & Clinical & Optometric Sciences, Technological University Dublin, City Campus, Dublin 8, Ireland
| | - Orla Howe
- Radiation and Environmental Science Centre (RESC), FOCAS Research Institute.,School of Biological and Health Sciences, Technological University Dublin, City Campus, Dublin 8, Ireland
| |
Collapse
|
7
|
Beinke C, Wanke C, Eder S, Port M. Cytogenetic Analysis After Temporary Residence in the Area of the Uncontrolled Ruthenium-106 Release in Russia in September 2017. HEALTH PHYSICS 2019; 117:598-605. [PMID: 31124834 DOI: 10.1097/hp.0000000000001097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In September and October 2017, elevated atmospheric ruthenium contamination was measured in several European countries. The most probable origin of this release of radionuclides was reconstructed to be the Southern Ural region. During that time, five workers from a German company stayed up to 2 wk about 120 km from the Chelyabinsk region in Ekaterinburg, Russia. No clinical symptoms were reported during or after the suspected radiation exposure, and no internal contamination was found in whole-body measurements. However, to investigate radiation protection issues and to clarify the workers' situation in order to reassure them, as they planned to continue working in Ekaterinburg, our laboratory was urgently requested by the company's occupational physician to perform biodosimetry using dicentric analysis to determine if the workers have been exposed to radiation by incorporation of radionuclides. The workers' dicentric yields have been compared to reference data of background frequencies in unexposed individuals, but, as it is not reasonable to quantify individual absorbed radiation doses from internalized beta emitters due to various confounding factors, individual dose estimation has not been performed. Dicentric frequencies for two workers differed significantly from the mean laboratory background level, which could have been induced by an exposure to incorporated radionuclides due to beta emissions by Ru or to gamma irradiation by the decay nuclide of Ru. However, the maximum absorbed radiation doses calculated for a resident in the Ru-contaminated area during that time does not correspond to the observed dicentric frequencies. It cannot be excluded that their dicentric frequencies were already elevated before September 2017, potentially induced by an earlier radiation exposure to diagnostic x rays or even by chance.
Collapse
Affiliation(s)
- C Beinke
- Bundeswehr Institute of Radiobiology affiliated with the University Ulm, Munich, Germany
| | - C Wanke
- Medizinische Hochschule Hannover, Stabsstelle Strahlenschutz und Abteilung Medizinische Physik
| | - S Eder
- Bundeswehr Institute of Radiobiology affiliated with the University Ulm, Munich, Germany
- Institute and Outpatient Clinic for Occupational, Social, and Environmental Medicine, Inner City Clinic, University Hospital of Munich (LMU), Munich, Germany
| | - M Port
- Bundeswehr Institute of Radiobiology affiliated with the University Ulm, Munich, Germany
| |
Collapse
|
8
|
Ryan TL, Escalona MB, Smith TL, Albanese J, Iddins CJ, Balajee AS. Optimization and validation of automated dicentric chromosome analysis for radiological/nuclear triage applications. MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS 2019; 847:503087. [PMID: 31699339 DOI: 10.1016/j.mrgentox.2019.503087] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Revised: 07/26/2019] [Accepted: 09/02/2019] [Indexed: 10/25/2022]
Abstract
Dicentric Chromosome Assay (DCA) is the most preferred cytogenetic technique for absorbed radiation dose assessment in exposed humans. However, DCA is somewhat impractical for triage application owing to its labor intensive and time consuming nature. Although lymphocyte culture for 48 h in vitro is inevitable for DCA, manual scoring of dicentric chromosomes (DCs) requires an additional time of 24-48 h, making the overall turnaround time of 72-96 h for dose estimation. To accelerate the speed of DC analysis for dose estimation, an automated tool was optimized and validated for triage mode of scoring. Several image training files were created to improve the specificity of automated DC analysis algorithm. Accuracy and efficiency of the automated (unsupervised) DC scoring was compared with the semi-automated scoring that involved human verification and correction of DCs (elimination of false positives and inclusion of true positives). DC scoring was performed by both automated and semi-automated modes for different doses of X-rays and γ-rays (0 Gy-5 Gy). Biodoses estimated from the frequencies of DCs detected by both automated (unsupervised) and semi-automated (supervised) scoring modes were grossly similar to the actual delivered doses in the range of 0.5 to 3 Gy of low LET radiation. We suggest that the automated DC tool can be effectively used for large scale radiological/nuclear incidents where a rapid segregation is essential for prioritizing moderately or severely exposed humans to receive appropriate medical countermeasures.
Collapse
Affiliation(s)
- Terri L Ryan
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Maria B Escalona
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Tammy L Smith
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Joseph Albanese
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, CT, USA
| | - Carol J Iddins
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Adayabalam S Balajee
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA.
| |
Collapse
|
9
|
Taraboletti A, Goudarzi M, Kabir A, Moon BH, Laiakis EC, Lacombe J, Ake P, Shoishiro S, Brenner D, Fornace AJ, Zenhausern F. Fabric Phase Sorptive Extraction-A Metabolomic Preprocessing Approach for Ionizing Radiation Exposure Assessment. J Proteome Res 2019; 18:3020-3031. [PMID: 31090424 PMCID: PMC7437658 DOI: 10.1021/acs.jproteome.9b00142] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The modern application of mass spectrometry-based metabolomics to the field of radiation assessment and biodosimetry has allowed for the development of prompt biomarker screenings for radiation exposure. Our previous work on radiation assessment, in easily accessible biofluids (such as urine, blood, saliva), has revealed unique metabolic perturbations in response to radiation quality, dose, and dose rate. Nevertheless, the employment of swift injury assessment in the case of a radiological disaster still remains a challenge as current sample processing can be time consuming and cause sample degradation. To address these concerns, we report a metabolomics workflow using a mass spectrometry-compatible fabric phase sorptive extraction (FPSE) technique. FPSE employs a matrix coated with sol-gel poly(caprolactone-b-dimethylsiloxane-b-caprolactone) that binds both polar and nonpolar metabolites in whole blood, eliminating serum processing steps. We confirm that the FPSE preparation technique combined with liquid chromatography-mass spectrometry can distinguish radiation exposure markers such as taurine, carnitine, arachidonic acid, α-linolenic acid, and oleic acid found 24 h after 8 Gy irradiation. We also note the effect of different membrane fibers on both metabolite extraction efficiency and the temporal stabilization of metabolites in whole blood at room temperature. These findings suggest that the FPSE approach could work in future technology to triage irradiated individuals accurately, via biomarker screening, by providing a novel method to stabilize biofluids between collection and sample analysis.
Collapse
Affiliation(s)
- Alexandra Taraboletti
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Maryam Goudarzi
- Department of Biochemistry and Molecular & Cellular Biology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
- Lerner Research Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, Ohio 44195, United States
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 Southwest Eighth Street, Miami, Florida 33199, United States
| | - Bo-Hyun Moon
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Evagelia C. Laiakis
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
- Department of Biochemistry and Molecular & Cellular Biology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Jerome Lacombe
- Center for Applied NanoBiosience and Medicine, University of Arizona, 475 North Fifth Street, Phoenix, Arizona 85004, United States
| | - Pelagie Ake
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Sueoka Shoishiro
- Center for Applied NanoBiosience and Medicine, University of Arizona, 475 North Fifth Street, Phoenix, Arizona 85004, United States
| | - David Brenner
- Center for Radiological Research, Columbia University, 630 West 168th Street, New York, New York 10032, United States
| | - Albert J. Fornace
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
- Department of Biochemistry and Molecular & Cellular Biology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Frederic Zenhausern
- Center for Applied NanoBiosience and Medicine, University of Arizona, 475 North Fifth Street, Phoenix, Arizona 85004, United States
- Translational Genomics Research Institute, 445 North Fifth Street, Phoenix, Arizona 85004, United States
- Department of Basic Medical Sciences, College of Medicine Phoenix, 425 North Fifth Street, Phoenix, Arizona 85004, United States
| |
Collapse
|
10
|
Balajee AS, Escalona M, Iddins CJ, Shuryak I, Livingston GK, Hanlon D, Dainiak N. Development of electronic training and telescoring tools to increase the surge capacity of dicentric chromosome scorers for radiological/nuclear mass casualty incidents. Appl Radiat Isot 2018; 144:111-117. [PMID: 30572199 DOI: 10.1016/j.apradiso.2018.12.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 11/02/2018] [Accepted: 12/04/2018] [Indexed: 11/16/2022]
Abstract
Dicentric chromosome assay (DCA) is most frequently used for estimating the absorbed radiation dose in the peripheral blood lymphocytes of humans after occupational or incidental radiation exposure. DCA is considered to be the "gold standard" for estimating the absorbed radiation dose because the dicentric chromosome formation is fairly specific to ionizing radiation exposure and its baseline frequency is extremely low in non-exposed humans. However, performance of DCA for biodosimetry is labor intensive and time-consuming making its application impractical for radiological/nuclear mass casualty incidents. Realizing the critical need for rapid dose estimation particularly after radiological/nuclear disaster events, several laboratories have initiated efforts to automate some of the procedural steps involved in DCA. Although metaphase image capture and dicentric chromosome analysis have been automated using commercially available platforms, lack or an insufficient number of these platforms may pose a serious bottleneck when hundreds and thousands of samples need to be analyzed for rapid dose estimation. To circumvent this problem, a web-based approach for telescoring was initiated by our laboratory, which enabled the cytogeneticists around the globe to analyze and score digital images. To further increase the surge capacity of dicentric scorers, we recently initiated a dicentric training and scoring exercise involving a total of 50 volunteers at all academic levels without any prerequisite for experience in radiation cytogenetics. Out of the 50 volunteers enrolled thus far, only one outlier was found who overestimated the absorbed radiation dose. Our approach of training the civilians in dicentric chromosome analysis holds great promise for increasing the surge capacity of dicentric chromosome scorers for a rapid biodosimetry in the case of mass casualty scenarios.
Collapse
Affiliation(s)
- Adayabalam S Balajee
- Radiation Emergency Assistance Center and Training Site, Cytogenetics Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA.
| | - Maria Escalona
- Radiation Emergency Assistance Center and Training Site, Cytogenetics Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Carol J Iddins
- Radiation Emergency Assistance Center and Training Site, Cytogenetics Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Igor Shuryak
- Center for Radiological Research, Department of Radiation Oncology, Columbia University Medical Center, New York City, NY, USA
| | - Gordon K Livingston
- Radiation Emergency Assistance Center and Training Site, Cytogenetics Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Don Hanlon
- Department of Health, Energy and Environment-Health, Oak Ridge Associated Universities, Oak Ridge, TN, USA
| | - Nicholas Dainiak
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, CT, USA
| |
Collapse
|
11
|
Balajee AS, Smith T, Ryan T, Escalona M, Dainiak N. DEVELOPMENT OF A MINIATURIZED VERSION OF DICENTRIC CHROMOSOME ASSAY TOOL FOR RADIOLOGICAL TRIAGE. RADIATION PROTECTION DOSIMETRY 2018; 182:139-145. [PMID: 30247729 DOI: 10.1093/rpd/ncy127] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Indexed: 06/08/2023]
Abstract
Use of ionizing radiation (IR) in various industrial, medical and other applications can potentially increase the risk of medical, occupational or accidental human exposure. Additionally, in the event of a radiological or nuclear (R/N) incident, several tens of hundreds and thousands of people are likely to be exposed to IR. IR causes serious health effects including mortality from acute radiation syndrome and therefore it is imperative to determine the absorbed radiation dose, which will enable physicians in making an appropriate clinical 'life-saving' decision. The 'Dicentric Chromosome Assay (DCA)' is the gold standard for estimating the absorbed radiation dose but its performance is time consuming and laborious. Further, timely evaluation of dicentric chromosomes (DCs) for dose estimation in a large number of samples provides a bottleneck because of a limited number of trained personnel and a prolonged time for manual analysis. To circumvent some of these technical issues, we developed and optimized a miniaturized high throughput version of DCA (mini-DCA) in a 96-microtube matrix with bar-coded 1.4 ml tubes to enable the processing of a large number of samples. To increase the speed of DC analysis for radiation dose estimation, a semi-automated scoring was optimized using the Metafer DCScore algorithm. The accuracy of mini-DCA in dose estimation was verified and validated though comparison with conventional DCA performed in 15 ml conical tubes. The mini-DCA considerably reduced the sample processing time by a factor of 4 when compared to the conventional DCA. Further, the radiation doses estimated by mini-DCA using the triage mode of scoring (50 cells or 30 DCs) were similar to that of conventional DCA using 300-500 cells. The mini-DCA coupled with semi-automated DC scoring not only reduced the sample processing and analysis times by a factor of 4 but also enabled the processing of a large number of samples at once. Our mini-DCA method, once automated for high throughput robotic platforms, will be an effective radiological triage tool for mass casualty incidents.
Collapse
Affiliation(s)
- Adayabalam S Balajee
- Cytogenetics Biodosimetry Laboratory, Radiation Emergency Assistance Center and Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Tammy Smith
- Cytogenetics Biodosimetry Laboratory, Radiation Emergency Assistance Center and Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Terri Ryan
- Cytogenetics Biodosimetry Laboratory, Radiation Emergency Assistance Center and Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Maria Escalona
- Cytogenetics Biodosimetry Laboratory, Radiation Emergency Assistance Center and Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Nicholas Dainiak
- Cytogenetics Biodosimetry Laboratory, Radiation Emergency Assistance Center and Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| |
Collapse
|
12
|
Oestreicher U, Endesfelder D, Gomolka M, Kesminiene A, Lang P, Lindholm C, Rößler U, Samaga D, Kulka U. Automated scoring of dicentric chromosomes differentiates increased radiation sensitivity of young children after low dose CT exposure in vitro. Int J Radiat Biol 2018; 94:1017-1026. [PMID: 30028637 DOI: 10.1080/09553002.2018.1503429] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 05/28/2018] [Accepted: 06/29/2018] [Indexed: 12/12/2022]
Abstract
PURPOSE Automated detection of dicentric chromosomes from a large number of cells was applied to study age-dependent radiosensitivity after in vitro CT exposure of blood from healthy donors. MATERIALS AND METHODS Blood samples from newborns, children (2-5 years) and adults (20-50 years) were exposed in vitro to 0 mGy, 41 mGy and 978 mGy using a CT equipment. In this study, automated scoring based on 13,000-31,000 cells/dose point/age group was performed. Results for control and low dose points were validated by manually counting about 26,000 cells/dose point/age group. RESULTS For all age groups, the high number of analyzed cells enabled the detection of a significant increase in the frequency of radiation induced dicentric chromosomes in cells exposed to 41 mGy as compared to control cells. Moreover, differences between the age groups could be resolved for the low dose: young donors showed significantly increased risk for induced dicentrics at 41 mGy compared to adults. CONCLUSIONS The results very clearly demonstrate that the automated dicentric scoring method is capable of discerning radiation induced biomarkers in the low dose range (<100 mGy) and thus may open possibilities for large-scale molecular epidemiology studies in radiation protection.
Collapse
Affiliation(s)
- Ursula Oestreicher
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
| | - David Endesfelder
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
| | - Maria Gomolka
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
| | | | - Peter Lang
- c Department of Radiation Oncology , University Hospital, LMU , Munich , Germany
| | - Carita Lindholm
- d Radiation and Nuclear Safety Authority, STUK , Helsinki , Finland
| | - Ute Rößler
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
| | - Daniel Samaga
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
- e Research Unit Radiation Cytogenetics , Helmholtz Zentrum Muenchen , Oberschleissheim , Germany
| | - Ulrike Kulka
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
| |
Collapse
|
13
|
Beinke C, Port M, Ullmann R, Gilbertz K, Majewski M, Abend M. Analysis of Gene Expression Changes in PHA-M Stimulated Lymphocytes - Unraveling PHA Activity as Prerequisite for Dicentric Chromosome Analysis. Radiat Res 2018; 189:579-596. [PMID: 29613823 DOI: 10.1667/rr14974.1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Dicentric chromosome analysis (DCA) is the gold standard for individual radiation dose assessment. However, DCA is limited by the time-consuming phytohemagglutinin (PHA)-mediated lymphocyte activation. In this study using human peripheral blood lymphocytes, we investigated PHA-associated whole genome gene expression changes to elucidate this process and sought to identify suitable gene targets as a means of meeting our long-term objective of accelerating cell cycle kinetics to reduce DCA culture time. Human peripheral whole blood from three healthy donors was separately cultured in RPMI/FCS/antibiotics with BrdU and PHA-M. Diluted whole blood samples were transferred into PAXgene tubes at 0, 12, 24 and 36 h culture time. RNA was isolated and aliquots were used for whole genome gene expression screening. Microarray results were validated using qRT-PCR and differentially expressed genes [significantly (FDR corrected) twofold different from the 0 h value reference] were analyzed using several bioinformatic tools. The cell cycle positions and DNA-synthetic activities of lymphocytes were determined by analyzing the correlated total DNA content and incorporated BrdU level with flow cytometry after continued BrdU incubation. From 42,545 transcripts of the whole genome microarray 47.6%, on average, appeared expressed. The number of differentially expressed genes increased linearly from 855 to 2,858 and 4,607 at 12, 24 and 36 h after PHA addition, respectively. Approximately 2-3 times more up- than downregulated genes were observed with several hundred genes differentially expressed at each time point. Earliest enrichment was observed for gene sets related to the nucleus (12 h) followed by genes assigned to intracellular structures such as organelles (24 h) and finally genes related to the membrane and the extracellular matrix were enriched (36 h). Early gene expression changes at 12 h, in particular, were associated with protein classes such as chemokines/cytokines (e.g., CXCL1, CXCL2) and chaperones. Genes coding for biological processes involved in cell cycle control (e.g., MYBL2, RBL1, CCNA, CCNE) and DNA replication (e.g., POLA, POLE, MCM) appeared enriched at 24 h and later, but many more biological processes (42 altogether) showed enrichment as well. Flow cytometry data fit together with gene expression and bioinformatic analyses as cell cycle transition into S phase was observed with interindividual differences from 12 h onward, whereas progression into G2 as well as into the second G1 occurred from 36 h onward after activation. Gene set enrichment analysis over time identifies, in particular, two molecular categories of PHA-responsive gene targets (cytokine and cell cycle control genes). Based on that analysis target genes for cell cycle acceleration in lymphocytes have been identified ( CDKN1A/B/C, RBL-1/RBL-2, E2F2, Deaf-1), and it remains undetermined whether the time expenditure for DCA can be reduced by influencing gene expression involved in the regulatory circuits controlling PHA-associated cell cycle entry and/or progression at a specific early cell cycle phase.
Collapse
Affiliation(s)
- C Beinke
- Bundeswehr Institute of Radiobiology affiliated to the University Ulm, Munich, Germany
| | - M Port
- Bundeswehr Institute of Radiobiology affiliated to the University Ulm, Munich, Germany
| | - R Ullmann
- Bundeswehr Institute of Radiobiology affiliated to the University Ulm, Munich, Germany
| | - K Gilbertz
- Bundeswehr Institute of Radiobiology affiliated to the University Ulm, Munich, Germany
| | - M Majewski
- Bundeswehr Institute of Radiobiology affiliated to the University Ulm, Munich, Germany
| | - M Abend
- Bundeswehr Institute of Radiobiology affiliated to the University Ulm, Munich, Germany
| |
Collapse
|
14
|
Vinnikov VA. Optimizing the Microscopy Time Schedule for Chromosomal Dosimetry of High-dose and Partial-body Irradiations. Genome Integr 2017; 8:3. [PMID: 28250910 PMCID: PMC5320789 DOI: 10.4103/2041-9414.198908] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The methodology of cytogenetic triage can be improved by optimizing a schedule of microscopy for different exposure scenarios. Chromosome aberrations were quantified by microscopy in human blood lymphocytes irradiated in vitro to ~2, 4, and 12 Gy acute 60Co γ-rays mixed with the unirradiated blood simulating 10%, 50%, 90%, and 100% exposure and in along with a sample from a homogeneous exposure to ~20 Gy. Biodosimetry workload was statistically modeled assuming that 0.5, 1, 5, or 25 h was available for scoring one case or for analysis of up to 1000 cells or 100 dicentrics plus centric rings by one operator. A strong negative correlation was established between the rates of aberration acquisition and cell recording. Calculations showed that the workload of 1 case per operator per·day (5 h of scoring by microscopy) allows dose estimates with high accuracy for either 90%–100% irradiations of 2 Gy or 50%–90% irradiations of 4–12 Gy; lethal homogeneous (100%) exposures of 12 and 20 Gy can be evaluated with just 1 h of microscopy. Triage analysis of 0.5 h scoring per case results in the minimum tolerable accuracy only for partial- and total-body exposure of 4–20 Gy. Time-related efficacy of conventional biodosimetry depends primarily on the aberration yield in the sample, which is dependent on the radiation dose and its distribution in the patient's body. An optimized schedule of microscopy scoring should be developed for different exposure scenarios in each laboratory to increase their preparedness to radiological emergencies.
Collapse
Affiliation(s)
- Volodymyr A Vinnikov
- Individual Radiosensitivity Group, Grigoriev Institute for Medical Radiology of the National Academy of Medical Science of Ukraine, Kharkiv, Ukraine
| |
Collapse
|
15
|
Ainsbury EA, Higueras M, Puig P, Einbeck J, Samaga D, Barquinero JF, Barrios L, Brzozowska B, Fattibene P, Gregoire E, Jaworska A, Lloyd D, Oestreicher U, Romm H, Rothkamm K, Roy L, Sommer S, Terzoudi G, Thierens H, Trompier F, Vral A, Woda C. Uncertainty of fast biological radiation dose assessment for emergency response scenarios. Int J Radiat Biol 2016; 93:127-135. [PMID: 27572921 DOI: 10.1080/09553002.2016.1227106] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
PURPOSE Reliable dose estimation is an important factor in appropriate dosimetric triage categorization of exposed individuals to support radiation emergency response. MATERIALS AND METHODS Following work done under the EU FP7 MULTIBIODOSE and RENEB projects, formal methods for defining uncertainties on biological dose estimates are compared using simulated and real data from recent exercises. RESULTS The results demonstrate that a Bayesian method of uncertainty assessment is the most appropriate, even in the absence of detailed prior information. The relative accuracy and relevance of techniques for calculating uncertainty and combining assay results to produce single dose and uncertainty estimates is further discussed. CONCLUSIONS Finally, it is demonstrated that whatever uncertainty estimation method is employed, ignoring the uncertainty on fast dose assessments can have an important impact on rapid biodosimetric categorization.
Collapse
Affiliation(s)
- Elizabeth A Ainsbury
- a Public Health England Centre for Radiation , Chemical and Environmental Hazards (PHE) , Chilton , UK
| | - Manuel Higueras
- a Public Health England Centre for Radiation , Chemical and Environmental Hazards (PHE) , Chilton , UK.,b Universitat Autonoma de Barcelona , Barcelona , Spain
| | - Pedro Puig
- b Universitat Autonoma de Barcelona , Barcelona , Spain
| | - Jochen Einbeck
- c Department of Mathematical Sciences , Durham University , Durham , UK
| | - Daniel Samaga
- d Bundesamt für Strahlenschutz (BfS) , Munich , Germany
| | | | | | - Beata Brzozowska
- e Stockholm University , Centre for Radiation Protection Research, Department of Molecular Bioscience, The Wenner-Gren Institute , Stockholm , Sweden.,f University of Warsaw , Faculty of Physics, Department of Biomedical Physics , Warsaw , Poland
| | | | - Eric Gregoire
- h Institut de radioprotection et de sûreté nucléaire (IRSN) , Paris , France
| | - Alicja Jaworska
- i Norwegian Radiation Protection Authority (NRPA) , Østerås , Norway
| | - David Lloyd
- a Public Health England Centre for Radiation , Chemical and Environmental Hazards (PHE) , Chilton , UK
| | | | - Horst Romm
- d Bundesamt für Strahlenschutz (BfS) , Munich , Germany
| | - Kai Rothkamm
- a Public Health England Centre for Radiation , Chemical and Environmental Hazards (PHE) , Chilton , UK.,j University Medical Center Hamburg-Eppendorf , Hamburg , Germany
| | - Laurence Roy
- h Institut de radioprotection et de sûreté nucléaire (IRSN) , Paris , France
| | - Sylwester Sommer
- k Institute of Nuclear Chemistry and Technology (ICHTJ) , Warsaw , Poland
| | - Georgia Terzoudi
- l National Centre for Scientific Research Demokritos , Athens , Greece
| | | | - Francois Trompier
- h Institut de radioprotection et de sûreté nucléaire (IRSN) , Paris , France
| | - Anne Vral
- m Ghent University , Ghent , Belgium
| | - Clemens Woda
- n Helmholtz Zentrum München (HMGU) , Neuherberg , Germany
| |
Collapse
|
16
|
Suto Y. Review of Cytogenetic analysis of restoration workers for Fukushima Daiichi nuclear power station accident. RADIATION PROTECTION DOSIMETRY 2016; 171:61-63. [PMID: 27473701 DOI: 10.1093/rpd/ncw187] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Japan faced with the nuclear accident of the Fukushima Daiichi Nuclear Power Station (NPS) caused by the combined disaster of the Great East Japan Earthquake and the subsequent tsunamis on 11 March 2011. National Institute of Radiological Sciences received all nuclear workers who were engaged in emergency response tasks at the NPS and suspected of being overexposed to acute radiation. Biological dosimetry by dicentric chromosome assay was helpful for medical triage and management of the workers.
Collapse
Affiliation(s)
- Yumiko Suto
- Research Program for Radiation Dosimetry, National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555, Japan
| |
Collapse
|
17
|
Moquet J, Barnard S, Staynova A, Lindholm C, Monteiro Gil O, Martins V, Rößler U, Vral A, Vandevoorde C, Wojewódzka M, Rothkamm K. The second gamma-H2AX assay inter-comparison exercise carried out in the framework of the European biodosimetry network (RENEB). Int J Radiat Biol 2016; 93:58-64. [DOI: 10.1080/09553002.2016.1207822] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Jayne Moquet
- Public Health England, Centre for Radiation Chemical and Environmental Hazards, Chilton, UK
| | - Stephen Barnard
- Public Health England, Centre for Radiation Chemical and Environmental Hazards, Chilton, UK
| | - Albena Staynova
- National Centre of Radiobiology and Radiation Protection, Sofia, Bulgaria
| | - Carita Lindholm
- Radiation and Nuclear Safety Authority (STUK), Helsinki, Finland
| | - Octávia Monteiro Gil
- Instituto Superior Técnico, Universidade de Lisboa, C2TN, Bobadela-LRS, Portugal
| | - Vanda Martins
- Instituto Superior Técnico, Universidade de Lisboa, C2TN, Bobadela-LRS, Portugal
| | - Ute Rößler
- Bundesamt für Strahlenschutz, Oberschleissheim, Germany
| | - Anne Vral
- Department of Basic Medical Sciences, Ghent University, Ghent, Belgium
| | - Charlot Vandevoorde
- Department of Basic Medical Sciences, Ghent University, Ghent, Belgium
- Themba LABS, National Research Foundation, Somerset West, South Africa
| | - Maria Wojewódzka
- Institute of Nuclear Chemistry and Technology, Centre for Radiobiology and Biological Dosimetry, Warsaw, Poland
| | - Kai Rothkamm
- Public Health England, Centre for Radiation Chemical and Environmental Hazards, Chilton, UK
- Department of Radiotherapy & Radio-Oncology, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
18
|
Ainsbury E, Badie C, Barnard S, Manning G, Moquet J, Abend M, Antunes AC, Barrios L, Bassinet C, Beinke C, Bortolin E, Bossin L, Bricknell C, Brzoska K, Buraczewska I, Castaño CH, Čemusová Z, Christiansson M, Cordero SM, Cosler G, Monaca SD, Desangles F, Discher M, Dominguez I, Doucha-Senf S, Eakins J, Fattibene P, Filippi S, Frenzel M, Georgieva D, Gregoire E, Guogyte K, Hadjidekova V, Hadjiiska L, Hristova R, Karakosta M, Kis E, Kriehuber R, Lee J, Lloyd D, Lumniczky K, Lyng F, Macaeva E, Majewski M, Vanda Martins S, McKeever SW, Meade A, Medipally D, Meschini R, M’kacher R, Gil OM, Montero A, Moreno M, Noditi M, Oestreicher U, Oskamp D, Palitti F, Palma V, Pantelias G, Pateux J, Patrono C, Pepe G, Port M, Prieto MJ, Quattrini MC, Quintens R, Ricoul M, Roy L, Sabatier L, Sebastià N, Sholom S, Sommer S, Staynova A, Strunz S, Terzoudi G, Testa A, Trompier F, Valente M, Hoey OV, Veronese I, Wojcik A, Woda C. Integration of new biological and physical retrospective dosimetry methods into EU emergency response plans – joint RENEB and EURADOS inter-laboratory comparisons. Int J Radiat Biol 2016; 93:99-109. [DOI: 10.1080/09553002.2016.1206233] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
- Elizabeth Ainsbury
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Christophe Badie
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Stephen Barnard
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Grainne Manning
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Jayne Moquet
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Michael Abend
- Bundeswehr Institute of Radiobiology (BIR), Munich, Germany
| | - Ana Catarina Antunes
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico (IST/ITN), Universidade de Lisboa, Bobadela-LRS, Portugal
| | | | - Celine Bassinet
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Paris, France
| | - Christina Beinke
- Bundeswehr Institute of Radiobiology affiliated to the University of Ulm (UULM), Munich, Germany
| | | | - Lily Bossin
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
- Durham University (DUR), Durham, UK
| | - Clare Bricknell
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Kamil Brzoska
- Institute of Nuclear Chemistry and Technology (INCT), Warsaw, Poland
| | - Iwona Buraczewska
- Institute of Nuclear Chemistry and Technology (INCT), Warsaw, Poland
| | | | - Zina Čemusová
- Státní ústav radiační ochrany (SÚRO), Prague, Czech Republic
| | | | | | - Guillaume Cosler
- Institut de Recherche Biomédicale des Armées (IRBA), Paris, France
| | | | | | - Michael Discher
- Salzburg University Department of Geography and Geology, Salzburg, Austria
| | | | | | - Jon Eakins
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | | | | | - Monika Frenzel
- PROCyTOX, Commissariat à l’Energie Atomique et aux Energies Alternatives, Université Paris-Saclay (CEA), Fontenay-aux-Roses, France
| | - Dimka Georgieva
- National Center of Radiobiology and Radiation Protection (NCRRP), Bulgaria
| | - Eric Gregoire
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Paris, France
| | | | | | | | - Rositsa Hristova
- National Center of Radiobiology and Radiation Protection (NCRRP), Bulgaria
| | - Maria Karakosta
- Laboratory of Health Physics, Radiobiology & Cytogenetics Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety National Center for Scientific Research “Demokritos” (NCSRD), Greece
| | - Enikő Kis
- National Public Health Centre – National Research Institute for Radiobiology and Radiohygiene (NRIRR), Hungary
| | - Ralf Kriehuber
- Radiation Biology Unit Forschungszentrum Jülich GmbH (FzJ), Jülich, Germany
| | - Jungil Lee
- Korea Atomic Energy Research Institute (KAERI), Daejeon, South Korea
| | - David Lloyd
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Katalin Lumniczky
- National Public Health Centre – National Research Institute for Radiobiology and Radiohygiene (NRIRR), Hungary
| | - Fiona Lyng
- Dublin Institute of Technology (DIT), Dublin, Ireland
| | - Ellina Macaeva
- Belgian Nuclear Research Centre (SCK-CEN), Mol, Belgium
- Ghent University (GU), Ghent, Belgium
| | | | - S. Vanda Martins
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico (IST/ITN), Universidade de Lisboa, Bobadela-LRS, Portugal
| | | | - Aidan Meade
- Dublin Institute of Technology (DIT), Dublin, Ireland
| | | | | | - Radhia M’kacher
- PROCyTOX, Commissariat à l’Energie Atomique et aux Energies Alternatives, Université Paris-Saclay (CEA), Fontenay-aux-Roses, France
| | - Octávia Monteiro Gil
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico (IST/ITN), Universidade de Lisboa, Bobadela-LRS, Portugal
| | - Alegria Montero
- Radiation Protection Service, IIS La Fe, Health Research Institute (LAFE), Spain
| | - Mercedes Moreno
- Laboratorio de Dosimetría Biológica, Servicio de Oncología Radioterápica, Hospital General Universitario Gregorio Marañón (SERMAS), Spain
| | | | - Ursula Oestreicher
- Bundesamt fuer Strahlenschutz (BfS), Department Radiation Protection and Health, Neuherberg, Germany
| | - Dominik Oskamp
- Radiation Biology Unit Forschungszentrum Jülich GmbH (FzJ), Jülich, Germany
| | | | - Valentina Palma
- Laboratory of Biosafety and Risk Assessment Division of Health Protection Technologies (ENEA) Casaccia Research Center, Italy
| | - Gabriel Pantelias
- Laboratory of Health Physics, Radiobiology & Cytogenetics Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety National Center for Scientific Research “Demokritos” (NCSRD), Greece
| | - Jerome Pateux
- Institut de Recherche Biomédicale des Armées (IRBA), Paris, France
| | - Clarice Patrono
- Laboratory of Biosafety and Risk Assessment Division of Health Protection Technologies (ENEA) Casaccia Research Center, Italy
| | - Gaetano Pepe
- Università degli Studi della Tuscia (UNITUS), Italy
| | - Matthias Port
- Bundeswehr Institute of Radiobiology (BIR), Munich, Germany
| | - María Jesús Prieto
- Laboratorio de Dosimetría Biológica, Servicio de Oncología Radioterápica, Hospital General Universitario Gregorio Marañón (SERMAS), Spain
| | | | - Roel Quintens
- Belgian Nuclear Research Centre (SCK-CEN), Mol, Belgium
| | - Michelle Ricoul
- PROCyTOX, Commissariat à l’Energie Atomique et aux Energies Alternatives, Université Paris-Saclay (CEA), Fontenay-aux-Roses, France
| | - Laurence Roy
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Paris, France
| | - Laure Sabatier
- PROCyTOX, Commissariat à l’Energie Atomique et aux Energies Alternatives, Université Paris-Saclay (CEA), Fontenay-aux-Roses, France
| | - Natividad Sebastià
- Radiation Protection Service, IIS La Fe, Health Research Institute (LAFE), Spain
| | | | - Sylwester Sommer
- Institute of Nuclear Chemistry and Technology (INCT), Warsaw, Poland
| | - Albena Staynova
- National Center of Radiobiology and Radiation Protection (NCRRP), Bulgaria
| | - Sonja Strunz
- Leibniz Institute for Farm Animal Biology (FBN), Dummerstorf, Germany
| | - Georgia Terzoudi
- Laboratory of Health Physics, Radiobiology & Cytogenetics Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety National Center for Scientific Research “Demokritos” (NCSRD), Greece
| | - Antonella Testa
- Laboratory of Biosafety and Risk Assessment Division of Health Protection Technologies (ENEA) Casaccia Research Center, Italy
| | - Francois Trompier
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Paris, France
| | - Marco Valente
- Institut de Recherche Biomédicale des Armées (IRBA), Paris, France
| | | | - Ivan Veronese
- Università degli Studi di Milano (UNIMI), Milano, Italy
| | | | - Clemens Woda
- Helmholtz Zentrum München (HMGU), Neuherberg, Germany
| |
Collapse
|
19
|
Beinke C, Port M, Lamkowski A, Abend M. Comparing seven mitogens with PHA-M for improved lymphocyte stimulation in dicentric chromosome analysis for biodosimetry. RADIATION PROTECTION DOSIMETRY 2016; 168:235-41. [PMID: 25958413 PMCID: PMC4884885 DOI: 10.1093/rpd/ncv286] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2015] [Accepted: 03/13/2015] [Indexed: 05/06/2023]
Abstract
Dicentric chromosome analysis (DCA) is the gold standard for individual radiation dose estimation. Two limiting factors of DCA are the time-consuming lymphocyte stimulation and proliferation using the lectin PHA-M and the upper dose limit of individual dose assessment of ∼4 Gy. By measuring the mitotic index (MI), the authors investigated systematically whether the stimulation of lymphocytes can be improved after administration of alternative (and combined) mitogens. The authors compared the lymphocyte stimulation effectiveness of the traditionally used PHA-M (from Phaseolus vulgaris) with seven cited mitogens by determination of MIs: five lectins namely CNA (concanavalin A), PW (pokeweed), LMA (Maackia amurensis), LTV (T. vulgaris), PHA-L (P. vulgaris) as well as LPS (lipopolysaccharide, Escherichia coli) and SLO (streptolysine O, Streptococcus pyogenes) were applied. The conventional protocol using PHA-M for lymphocyte stimulation proved to be superior over lower/higher PHA-M concentrations as well as seven other mitogens administered either alone or combined with SLO or LPS.
Collapse
Affiliation(s)
- C Beinke
- Bundeswehr Institute of Radiobiology Affiliated to the University Ulm, Neuherbergstr. 11, Munich 80937, Germany
| | - M Port
- Bundeswehr Institute of Radiobiology Affiliated to the University Ulm, Neuherbergstr. 11, Munich 80937, Germany
| | - A Lamkowski
- Bundeswehr Institute of Radiobiology Affiliated to the University Ulm, Neuherbergstr. 11, Munich 80937, Germany
| | - M Abend
- Bundeswehr Institute of Radiobiology Affiliated to the University Ulm, Neuherbergstr. 11, Munich 80937, Germany
| |
Collapse
|
20
|
Pujol M, Barrios L, Puig P, Caballín MR, Barquinero JF. A New Model for Biological Dose Assessment in Cases of Heterogeneous Exposures to Ionizing Radiation. Radiat Res 2016; 185:151-62. [PMID: 26771173 DOI: 10.1667/rr14145.1] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
In biological dosimetry by dicentric analysis, an exposure to radiation is considered non-homogeneous if the dicentric cell distribution shows overdispersion with respect to Poisson distribution. Traditionally, when this occurs, all non-homogeneous exposures are considered as partial-body exposures, assuming that there is only a mixture of irradiated and nonirradiated cells. The methods to estimate the dose in the irradiated fraction and the initial fraction of irradiated cells are based on separating which part of the cells without aberrations comes from the nonirradiated or irradiated fractions. In this study we show a new approach based on a mixed Poisson model, which allows for a distinction to be made between partial and heterogeneous exposures. To validate this approach blood samples from two donors, a male and a female, irradiated at different doses, were mixed at a 1:1 proportion to simulate partial and heterogeneous exposures. The results show a good agreement between the observed proportion of male and female cells and the proportion estimated by the model. Additionally, a good agreement was observed between the delivered doses, the initial fraction of cells and the ones estimated by the model. This good agreement was also observed after very high-dose irradiation (up to 17 Gy), when the lymphocyte cultures were treated with caffeine. Based on these results, we propose the use of this mixed Poisson model for a more accurate assessment of non-homogeneous exposures.
Collapse
Affiliation(s)
- Mònica Pujol
- a Unitat d'Antropologia Biològica, Departament de Biologia Animal, Biologia Vegetal i Ecologia
| | - Leonardo Barrios
- b Unitat de Biologia Cellular, Departament de Biologia Cel·lular, Fisiologia i Immunologia; and
| | - Pedro Puig
- c Departament de Matemàtiques, Universitat Autònoma de Barcelona, E-08193 Bellaterra, Catalonia, Spain
| | - María Rosa Caballín
- a Unitat d'Antropologia Biològica, Departament de Biologia Animal, Biologia Vegetal i Ecologia
| | | |
Collapse
|
21
|
Jaworska A, Ainsbury EA, Fattibene P, Lindholm C, Oestreicher U, Rothkamm K, Romm H, Thierens H, Trompier F, Voisin P, Vral A, Woda C, Wojcik A. Operational guidance for radiation emergency response organisations in Europe for using biodosimetric tools developed in EU MULTIBIODOSE project. RADIATION PROTECTION DOSIMETRY 2015; 164:165-169. [PMID: 25274532 DOI: 10.1093/rpd/ncu294] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In the event of a large-scale radiological emergency, the triage of individuals according to their degree of exposure forms an important initial step of the accident management. Although clinical signs and symptoms of a serious exposure may be used for radiological triage, they are not necessarily radiation specific and can lead to a false diagnosis. Biodosimetry is a method based on the analysis of radiation-induced changes in cells of the human body or in portable electronic devices and enables the unequivocal identification of exposed people who should receive medical treatment. The MULTIBIODOSE (MBD) consortium developed and validated several biodosimetric assays and adapted and tested them as tools for biological dose assessment in a mass-casualty event. Different biodosimetric assays were validated against the 'gold standard' of biological dosimetry-the dicentric assay. The assays were harmonised in such a way that, in an emergency situation, they can be run in parallel in a network of European laboratories. The aim of this guidance is to give a concise overview of the developed biodosimetric tools as well as how and when they can be used in an emergency situation.
Collapse
Affiliation(s)
- Alicja Jaworska
- Department of Monitoring and Research, Norwegian Radiation Protection Authority, Oesteraas, Norway
| | - Elizabeth A Ainsbury
- Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Didcot, Oxon, UK
| | - Paola Fattibene
- Department Technology and Health, Istituto Superiore di Sanità, Rome, Italy
| | - Carita Lindholm
- Department of Environmental Radiation Surveillance, Radiation and Nuclear Safety Authority, Helsinki, Finland
| | - Ursula Oestreicher
- Department Radiation Protection and Health, Bundesamt fuer Strahlenschutz, Oberschleissheim, Germany
| | - Kai Rothkamm
- Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Didcot, Oxon, UK
| | - Horst Romm
- Department Radiation Protection and Health, Bundesamt fuer Strahlenschutz, Oberschleissheim, Germany
| | - Hubert Thierens
- Department of Basic Medical Sciences, Faculty of Medicine and Health Sciences, Universiteit Gent, Gent, Belgium
| | - Francois Trompier
- Department of Radiobiology and Epidemiology, Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-roses, France
| | - Philippe Voisin
- Department of Radiobiology and Epidemiology, Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-roses, France
| | - Anne Vral
- Department of Basic Medical Sciences, Faculty of Medicine and Health Sciences, Universiteit Gent, Gent, Belgium
| | - Clemens Woda
- Institute of Radiation Biology, Helmholtz Zentrum München, Neuherberg, Germany
| | - Andrzej Wojcik
- Centre for Radiation Protection Research, MBW Department, Stockholm University, Stockholm, Sweden
| |
Collapse
|