1
|
Woeppel KM, Cui XT. Nanoparticle and Biomolecule Surface Modification Synergistically Increases Neural Electrode Recording Yield and Minimizes Inflammatory Host Response. Adv Healthc Mater 2021; 10:e2002150. [PMID: 34190425 DOI: 10.1002/adhm.202002150] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 06/08/2021] [Indexed: 11/08/2022]
Abstract
Due to their ability to interface with neural tissues, neural electrodes are the key tool used for neurophysiological studies, electrochemical detection, brain computer interfacing, and countless neuromodulation therapies and diagnostic procedures. However, the long-term applications of neural electrodes are limited by the inflammatory host tissue response, decreasing detectable electrical signals, and insulating the device from the native environment. Surface modification methods are proposed to limit these detrimental responses but each has their own limitations. Here, a combinatorial approach is presented toward creating a stable interface between the electrode and host tissues. First, a thiolated nanoparticle (TNP) coating is utilized to increase the surface area and roughness. Next, the neural adhesion molecule L1 is immobilized to the nanoparticle modified substrate. In vitro, the combined nanotopographical and bioactive modifications (TNP+L1) elevate the bioactivity of L1, which is maintained for 28 d. In vivo, TNP+L1 modification improves the recording performance of the neural electrode arrays compared to TNP or L1 modification alone. Postmortem histology reveals greater neural cell density around the TNP+L1 coating while eliminating any inflammatory microglial encapsulation after 4 weeks. These results demonstrate that nanotopographical and bioactive modifications synergistically produce a seamless neural tissue interface for chronic neural implants.
Collapse
Affiliation(s)
- Kevin M. Woeppel
- Department of Bioengineering University of Pittsburgh Pittsburgh PA 15260 USA
- Center for the Neural basis of Cognition Pittsburgh PA 15260 USA
| | - Xinyan Tracy Cui
- Department of Bioengineering University of Pittsburgh Pittsburgh PA 15260 USA
- Center for the Neural basis of Cognition Pittsburgh PA 15260 USA
- McGowan Institute for Regenerative Medicine Pittsburgh PA 15260 USA
| |
Collapse
|
2
|
Wu CY, Guan ZY, Lin PC, Chen ST, Lin PK, Chen PC, Chao PHG, Chen HY. Defined cell adhesion for silicon-based implant materials by using vapor-deposited functional coatings. Colloids Surf B Biointerfaces 2018; 175:545-553. [PMID: 30579055 DOI: 10.1016/j.colsurfb.2018.12.034] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 12/11/2018] [Accepted: 12/12/2018] [Indexed: 01/01/2023]
Abstract
The field of implantable electronics relies on using silicon materials due to the merits of a well-established fabrication process and favorable properties; of particular interest is the surface modification of such materials. In the present study, we introduce a surface modification technique based on coatings of functionalized Parylene on silicon substrates, where the modified layers provide a defined cell adhesion capability for the resultant silicon materials/devices. Functionalization of Parylene was achieved during a one-step chemical vapor deposition (CVD) polymerization process, forming NHS ester-functionalized Parylene, and subsequent RGD attachment was enabled via a conjugation reaction between the NHS ester and amine groups. The modification procedures additionally provided a clean and gentle approach to avoid thermal excursions, intense irradiation, chemicals, or solvents that might damage delicate structures or sensitive molecules on the devices. The modification layers exhibited excellent mechanical strength on the substrate, meeting the high standards of the American Society for Testing and Materials (ASTM), and the resultant cell adherence property was verified by a centrifugation assay and the analysis of attached cell morphologies; the results collectively demonstrated robust and sustainable modification layers of the NHS ester-functionalized Parylene and confirmed that the cell-adherence property imparted by using this facile modification technique was effective. The modification technology is expected to benefit the design of prospective interface properties for silicon-based devices and related industrial products.
Collapse
Affiliation(s)
- Chih-Yu Wu
- Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Zhen-Yu Guan
- Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Pin-Chen Lin
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, Taipei 10608, Taiwan
| | - Shih-Ting Chen
- Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Po-Kang Lin
- Department of Ophthalmology, Taipei Veterans General Hospital, Taipei 11221, Taiwan
| | - Po-Chun Chen
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
| | - Pen-Hsiu Grace Chao
- Department of Biomedical Engineering, National Taiwan University, Taipei 10617, Taiwan.
| | - Hsien-Yeh Chen
- Department of Chemical Engineering, National Taiwan University, Taipei 10617, Taiwan; Advanced Research Center for Green Materials Science and Technology, National Taiwan University, Taipei 10617, Taiwan.
| |
Collapse
|
3
|
Won SM, Song E, Zhao J, Li J, Rivnay J, Rogers JA. Recent Advances in Materials, Devices, and Systems for Neural Interfaces. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2018; 30:e1800534. [PMID: 29855089 DOI: 10.1002/adma.201800534] [Citation(s) in RCA: 92] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 02/28/2018] [Indexed: 06/08/2023]
Abstract
Technologies capable of establishing intimate, long-lived optical/electrical interfaces to neural systems will play critical roles in neuroscience research and in the development of nonpharmacological treatments for neurological disorders. The development of high-density interfaces to 3D populations of neurons across entire tissue systems in living animals, including human subjects, represents a grand challenge for the field, where advanced biocompatible materials and engineered structures for electrodes and light emitters will be essential. This review summarizes recent progress in these directions, with an emphasis on the most promising demonstrated concepts, materials, devices, and systems. The article begins with an overview of electrode materials with enhanced electrical and/or mechanical performance, in forms ranging from planar films, to micro/nanostructured surfaces, to 3D porous frameworks and soft composites. Subsequent sections highlight integration with active materials and components for multiplexed addressing, local amplification, wireless data transmission, and power harvesting, with multimodal operation in soft, shape-conformal systems. These advances establish the foundations for scalable architectures in optical/electrical neural interfaces of the future, where a blurring of the lines between biotic and abiotic systems will catalyze profound progress in neuroscience research and in human health/well-being.
Collapse
Affiliation(s)
- Sang Min Won
- Department of Electrical and Computer Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Urbana, IL, 61801, USA
| | - Enming Song
- Department of Materials Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Northwestern University, Evanston, IL, 60208, USA
| | - Jianing Zhao
- Department of Mechanical Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Urbana, IL, 61801, USA
| | - Jinghua Li
- Department of Materials Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Northwestern University, Evanston, IL, 60208, USA
| | - Jonathan Rivnay
- Department of Biomedical Engineering, Simpson Querrey Institute for Nanobiotechnology, Northwestern University, Evanston, IL, 60208, USA
| | - John A Rogers
- Center for Bio-Integrated Electronics, Department of Materials Science and Engineering, Biomedical Engineering, Chemistry, Mechanical Engineering, Electrical Engineering and Computer Science, and Neurological Surgery, Simpson Querrey Institute for Nano/biotechnology, McCormick School of Engineering and Feinberg School of Medicine, Northwestern University, Evanston, IL, 60208, USA
| |
Collapse
|
4
|
Abdallah MN, Badran Z, Ciobanu O, Hamdan N, Tamimi F. Strategies for Optimizing the Soft Tissue Seal around Osseointegrated Implants. Adv Healthc Mater 2017; 6. [PMID: 28960892 DOI: 10.1002/adhm.201700549] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 07/12/2017] [Indexed: 12/20/2022]
Abstract
Percutaneous and permucosal devices such as catheters, infusion pumps, orthopedic, and dental implants are commonly used in medical treatments. However, these useful devices breach the soft tissue barrier that protects the body from the outer environment, and thus increase bacterial infections resulting in morbidity and mortality. Such associated infections can be prevented if these devices are effectively integrated with the surrounding soft tissue, and thus creating a strong seal from the surrounding environment. However, so far, there are no percutaneous/permucosal medical devices able to prevent infection by achieving strong integration at the soft tissue-device interface. This review gives an insight into the current status of research into soft tissue-implant interface and the challenges associated with these interfaces. Biological soft/hard tissue interfaces may provide insights toward engineering better soft tissue interfaces around percutaneous devices. In this review, focus is put on the history and current findings as well as recent progress of the strategies aiming to develop a strong soft tissue seal around osseointegrated implants, such as orthopedic and dental implants.
Collapse
Affiliation(s)
- Mohamed-Nur Abdallah
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
- Division of Orthodontics; Faculty of Dentistry; Toronto University; Toronto M5G 1G6 ON Canada
| | - Zahi Badran
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
- Department of Periodontology (CHU/Rmes Inserm U1229/UIC11); Faculty of Dental Surgery; University of Nantes; Nantes 44042 France
| | - Ovidiu Ciobanu
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
| | - Nader Hamdan
- Department of Dental Clinical Sciences; Faculty of Dentistry; Dalhousie University; Halifax B3H 4R2 NS Canada
| | - Faleh Tamimi
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
| |
Collapse
|
5
|
Gällentoft L, Pettersson LME, Danielsen N, Schouenborg J, Prinz CN, Linsmeier CE. Impact of degradable nanowires on long-term brain tissue responses. J Nanobiotechnology 2016; 14:64. [PMID: 27507159 PMCID: PMC4979107 DOI: 10.1186/s12951-016-0216-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2016] [Accepted: 08/03/2016] [Indexed: 01/12/2023] Open
Abstract
Background A promising approach to improve the performance of neural implants consists of adding nanomaterials, such as nanowires, to the surface of the implant. Nanostructured interfaces could improve the integration and communication stability, partly through the reduction of the cell-to-electrode distance. However, the safety issues of implanted nanowires in the brain need to be evaluated and understood before nanowires can be used on the surface of implants for long periods of time. To this end we here investigate whether implanted degradable nanowires offer any advantage over non-degradable nanowires in a long-term in vivo study (1 year) with respect to brain tissue responses. Results The tissue response after injection of degradable silicon oxide (SiOx)-coated gallium phosphide nanowires and biostable hafnium oxide-coated GaP nanowires into the rat striatum was compared. One year after nanowire injection, no significant difference in microglial or astrocytic response, as measured by staining for ED1 and glial fibrillary acidic protein, respectively, or in neuronal density, as measured by staining for NeuN, was found between degradable and biostable nanowires. Of the cells investigated, only microglia cells had engulfed the nanowires. The SiOx-coated nanowire residues were primarily seen in aggregated hypertrophic ED1-positive cells, possibly microglial cells that have fused to create multinucleated giant cells. Occasionally, degradable nanowires with an apparently intact shape were found inside single, small ED1-positive cells. The biostable nanowires were found intact in microglia cells of both phenotypes described. Conclusion The present study shows that the degradable nanowires remain at least partly in the brain over long time periods, i.e. 1 year; however, no obvious bio-safety issues for this degradable nanomaterial could be detected. Electronic supplementary material The online version of this article (doi:10.1186/s12951-016-0216-7) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Lina Gällentoft
- Department of Experimental Medical Science, Medical Faculty, Neuronano Research Center (NRC), Lund University, Scheelevägen 2, 223 81, Lund, Sweden.
| | - Lina M E Pettersson
- Department of Experimental Medical Science, Medical Faculty, Neuronano Research Center (NRC), Lund University, Scheelevägen 2, 223 81, Lund, Sweden
| | - Nils Danielsen
- Department of Experimental Medical Science, Medical Faculty, Neuronano Research Center (NRC), Lund University, Scheelevägen 2, 223 81, Lund, Sweden
| | - Jens Schouenborg
- Department of Experimental Medical Science, Medical Faculty, Neuronano Research Center (NRC), Lund University, Scheelevägen 2, 223 81, Lund, Sweden
| | - Christelle N Prinz
- Department of Experimental Medical Science, Medical Faculty, Neuronano Research Center (NRC), Lund University, Scheelevägen 2, 223 81, Lund, Sweden. .,Division of Solid State Physics/NanoLund, Lund University, P.O. Box 118, 221 00, Lund, Sweden.
| | - Cecilia Eriksson Linsmeier
- Department of Experimental Medical Science, Medical Faculty, Neuronano Research Center (NRC), Lund University, Scheelevägen 2, 223 81, Lund, Sweden.
| |
Collapse
|
6
|
Bioinspired anchoring AgNPs onto micro-nanoporous TiO2 orthopedic coatings: Trap-killing of bacteria, surface-regulated osteoblast functions and host responses. Biomaterials 2015; 75:203-222. [PMID: 26513414 DOI: 10.1016/j.biomaterials.2015.10.035] [Citation(s) in RCA: 197] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2015] [Revised: 10/12/2015] [Accepted: 10/14/2015] [Indexed: 01/10/2023]
Abstract
The therapeutic applications of silver nanoparticles (AgNPs) against biomedical device-associated infections (BAI), by local delivery, are encountered with risks of detachment, instability and nanotoxicity in physiological milieus. To firmly anchor AgNPs onto modified biomaterial surfaces through tight physicochemical interactions would potentially relieve these concerns. Herein, we present a strategy for hierarchical TiO2/Ag coating, in an attempt to endow medical titanium (Ti) with anticorrosion and antibacterial properties whilst maintaining normal biological functions. In brief, by harnessing the adhesion and reactivity of bioinspired polydopamine, silver nanoparticles were easily immobilized onto peripheral surface and incorporated into interior cavity of a micro/nanoporous TiO2 ceramic coating in situ grown from template Ti. The resulting coating protected the substrate well from corrosion and gave a sustained release of Ag(+) up to 28 d. An interesting germicidal effect, termed "trap-killing", was observed against Staphylococcus aureus strain. The multiple osteoblast responses, i.e. adherence, spreading, proliferation, and differentiation, were retained normal or promoted, via a putative surface-initiated self-regulation mechanism. After subcutaneous implantation for a month, the coated specimens elicited minimal, comparable inflammatory responses relative to the control. Moreover, this simple and safe functionalization strategy manifested a good degree of flexibility towards three-dimensional sophisticated objects. Expectedly, it can become a prospective bench to bedside solution to current challenges facing orthopedics.
Collapse
|
7
|
Abstract
Clinicians and investigators have been implanting biomedical devices into patients and experimental animals for centuries. There is a characteristic complex inflammatory response to the presence of the biomedical device with diverse cell signaling, followed by migration of fibroblasts to the implant surface and the eventual walling off of the implant in a collagen capsule. If the device is to interact with the surrounding tissues, the collagen envelope will eventually incapacitate the device or myofibroblasts can cause capsular contracture with resulting distortion, migration, or firmness. This review analyzes the various tactics used in the past to modify or control capsule formation with suggestions for future investigative approaches.
Collapse
|
8
|
Ahmed AF, Zakaria KM. Synthesis, characterization, and biocompatibility of poly (acrylic acid/methyl methacrylate)-grafted-poly (ethylene-co-tetrafluoroethylene) film for prosthetic cardiac valves. Colloid Polym Sci 2014. [DOI: 10.1007/s00396-014-3383-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
9
|
Mei S, Wang H, Wang W, Tong L, Pan H, Ruan C, Ma Q, Liu M, Yang H, Zhang L, Cheng Y, Zhang Y, Zhao L, Chu PK. Antibacterial effects and biocompatibility of titanium surfaces with graded silver incorporation in titania nanotubes. Biomaterials 2014; 35:4255-65. [DOI: 10.1016/j.biomaterials.2014.02.005] [Citation(s) in RCA: 252] [Impact Index Per Article: 22.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Accepted: 02/04/2014] [Indexed: 02/08/2023]
|
10
|
Shin HY, Frechette DM, Rohner N, Zhang X, Puleo DA, Bjursten LM. Dependence of macrophage superoxide release on the pulse amplitude of an applied pressure regime: a potential factor at the soft tissue-implant interface. J Tissue Eng Regen Med 2013; 10:E227-38. [DOI: 10.1002/term.1789] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2012] [Revised: 12/26/2012] [Accepted: 05/27/2013] [Indexed: 01/21/2023]
Affiliation(s)
- Hainsworth Y. Shin
- Center for Biomedical Engineering; University of Kentucky; Lexington KY USA
| | | | - Nathan Rohner
- Center for Biomedical Engineering; University of Kentucky; Lexington KY USA
| | - Xiaoyan Zhang
- Center for Biomedical Engineering; University of Kentucky; Lexington KY USA
| | - David A. Puleo
- Center for Biomedical Engineering; University of Kentucky; Lexington KY USA
| | | |
Collapse
|
11
|
Rydén L, Molnar D, Esposito M, Johansson A, Suska F, Palmquist A, Thomsen P. Early inflammatory response in soft tissues induced by thin calcium phosphates. J Biomed Mater Res A 2013; 101:2712-7. [PMID: 23463679 DOI: 10.1002/jbm.a.34571] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2012] [Revised: 12/11/2012] [Accepted: 12/17/2012] [Indexed: 12/19/2022]
Abstract
The inflammatory response to titanium and hydroxyapatite (HA)-coated titanium in living tissue is controlled by a number of humoral factors, of which monocyte chemoattractant protein-1 (MCP-1) has been specifically linked to the recruitment of monocytes. These cells subsequently mature into tissue-bound macrophages. Macrophages adhering to the proteins adsorbed at the implant surface play a pivotal role in initiating the rejection or integration of the foreign material. Despite this, little is known about the initial inflammatory events that occur in soft tissues following the implantation of titanium and HA-coated titanium implants. In this study, circular discs of commercially pure titanium (c.p. Ti) with either a thin crystalline HA coating or amorphous HA coating or uncoated were implanted subcutaneously into rats. The implants were retrieved after 24 and 72 h. The lactate dehydrogenase (LD) activity, DNA content, expression of MCP-1, interleukin-10 (IL-10), tumor necrosis factor α (TNF-α), as well as monocyte and polymorphonuclear granulocyte counts in the exudate surrounding the implants were analyzed. There were significantly higher DNA and LD levels around the titanium implants at 24 h compared with HA-coated titanium. A rapid decrease in MCP-1 levels was observed for all the implants over the period of observation. No statistically significant differences were found between the two HA-coated implants. Our results suggest a difference in the early soft-tissue response to HA-coated implants when compared with titanium implants, expressed as a downregulation of inflammatory cell recruitment. This suggests that thin HA coatings are promising surfaces for soft tissue applications.
Collapse
Affiliation(s)
- L Rydén
- Department of Biomaterials, Sahlgrenska Academy at University of Gothenburg, Göteborg, Sweden
| | | | | | | | | | | | | |
Collapse
|
12
|
Isackson D, Cook KJ, McGill LD, Bachus KN. Mesenchymal stem cells increase collagen infiltration and improve wound healing response to porous titanium percutaneous implants. Med Eng Phys 2012; 35:743-53. [PMID: 22940446 DOI: 10.1016/j.medengphy.2012.08.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2011] [Revised: 07/31/2012] [Accepted: 08/07/2012] [Indexed: 01/09/2023]
Abstract
Epidermal downgrowth, commonly associated with long-term percutaneous implants, weakens the skin-implant seal and greatly increases the vulnerability of the site to infection. To improve the skin attachment and early tissue integration with porous metal percutaneous implants, we evaluated the effect of bone marrow-derived mesenchymal stem cells (BMMSCs) to provide wound healing cues and vascularization to the dermal and epidermal tissues in establishing a barrier with the implant. Two porous metal percutaneous implants, one treated with BMMSCs and one untreated, were placed subdermally on the dorsum of Lewis rats. Implants were evaluated at 0, 3, 7, 28, and 56 days after implantation. Histological analyses evaluated cellular infiltrates, vascularization, quantity and quality of tissue ingrowth, epidermal downgrowth, and fibrous encapsulation. The amount of collagen infiltrating the porous coating was significantly greater for the BMMSC-treated implants at 3 and 28 days post implantation compared to untreated implants. There was an early influx and resolution of cellular inflammatory infiltrates in the treated implants compared to the untreated, though not statistically significant. Vascularization increased over time in both treated and untreated implants, with no statistical significance. Epidermal downgrowth was minimally observed in all implants with or without the BMMSC treatment. Our results suggest that BMMSCs can influence an early and rapid resolution of acute and chronic inflammation in wound healing, and can stimulate early collagen deposition and granulation tissue associated with later stages of wound repair. These findings provide evidence that BMMSCs can stimulate a more rapid and improved barrier between the skin and porous metal percutaneous implant.
Collapse
Affiliation(s)
- Dorthyann Isackson
- Orthopaedic Research Laboratory, University of Utah Orthopaedic Center, Salt Lake City, UT 84108, USA
| | | | | | | |
Collapse
|
13
|
Jarvis KL, Barnes TJ, Prestidge CA. Surface chemistry of porous silicon and implications for drug encapsulation and delivery applications. Adv Colloid Interface Sci 2012; 175:25-38. [PMID: 22521238 DOI: 10.1016/j.cis.2012.03.006] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2011] [Revised: 03/20/2012] [Accepted: 03/23/2012] [Indexed: 01/09/2023]
Abstract
Porous silicon (pSi) has a number of unique properties that appoint it as a potential drug delivery vehicle; high loading capacity, controllable surface chemistry and structure, and controlled release properties. The native Si(y)SiH(x) terminated pSi surface is highly reactive and prone to spontaneous oxidation. Surface modification is used to stabilize the pSi surface but also to produce surfaces with desired drug delivery behavior, typically via oxidation, hydrosilylation or thermal carbonization. A number of advanced characterization techniques have been used to analyze pSi surface chemistry, including X-ray photoelectron spectroscopy and time of flight secondary ion mass spectrometry. Surface modification not only stabilizes the pSi surface but determines its charge, wettability and dissolution properties. Manipulation of these parameters can impact drug encapsulation by altering drug-pSi interactions. pSi has shown to be a successful vehicle for the delivery of poorly soluble drugs and protein therapeutics. Surface modification influences drug pore penetration, crystallinity, loading level and dissolution rate. Surface modification of pSi shows great potential for drug delivery applications by controlling pSi-drug interactions. Controlling these interactions allows specific drug release behaviors to be engineered to aid in the delivery of previously challenging therapeutics. Within this review, different pSi modification techniques will be outlined followed by a summary of how pSi surface modification has been used to improve drug encapsulation and delivery.
Collapse
Affiliation(s)
- Karyn L Jarvis
- Ian Wark Research Institute, University of South Australia, Mawson Lakes, SA, Australia
| | | | | |
Collapse
|
14
|
Persson J, Danielsen N, Wallman L. Porous silicon as a neural electrode material. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 18:1301-8. [DOI: 10.1163/156856207782177846] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Affiliation(s)
- Jörgen Persson
- a Department of Electrical Measurements, Lund University, Lund Institute of Technology, P.O. Box 118, SE-22184 Lund, Sweden
| | - Nils Danielsen
- b Department of Experimental Medical Science, NeuroNano Science Research Center, BMC F10, Lund University, SE-22184 Lund, Sweden
| | - Lars Wallman
- c Department of Electrical Measurements, Lund University, Lund Institute of Technology, P.O. Box 118, SE-22184 Lund, Sweden; Department of Experimental Medical Science, NeuroNano Science Research Center, BMC F10, Lund University, SE-22184 Lund, Sweden
| |
Collapse
|
15
|
Hayes JS, Welton JL, Wieling R, Richards RG. In vivo evaluation of defined polished titanium surfaces to prevent soft tissue adhesion. J Biomed Mater Res B Appl Biomater 2012; 100:611-7. [DOI: 10.1002/jbm.b.31967] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2011] [Revised: 07/12/2011] [Accepted: 07/12/2011] [Indexed: 11/12/2022]
|
16
|
Isackson D, McGill LD, Bachus KN. Percutaneous implants with porous titanium dermal barriers: an in vivo evaluation of infection risk. Med Eng Phys 2010; 33:418-26. [PMID: 21145778 DOI: 10.1016/j.medengphy.2010.11.007] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2010] [Revised: 11/04/2010] [Accepted: 11/07/2010] [Indexed: 11/28/2022]
Abstract
Osseointegrated percutaneous implants are a promising prosthetic alternative for a subset of amputees. However, as with all percutaneous implants, they have an increased risk of infection since they breach the skin barrier. Theoretically, host tissues could attach to the metal implant creating a barrier to infection. When compared with smooth surfaces, it is hypothesized that porous surfaces improve the attachment of the host tissues to the implant, and decrease the infection risk. In this study, four titanium implants, manufactured with a percutaneous post and a subcutaneous disk, were placed subcutaneously on the dorsum of eight New Zealand White rabbits. Beginning at four weeks post-op, the implants were inoculated weekly with 10(8) CFU Staphylococcus aureus until signs of clinical infection presented. While we were unable to detect a difference in the incidence of infection of the porous metal implants, smooth surface (no porous coating) percutaneous and subcutaneous components had a 7-fold increased risk of infection compared to the implants with a porous coating on one or both components. The porous coated implants displayed excellent tissue ingrowth into the porous structures; whereas, the smooth implants were surrounded with a thick, organized fibrotic capsule that was separated from the implant surface. This study suggests that porous coated metal percutaneous implants are at a significantly lower risk of infection when compared to smooth metal implants. The smooth surface percutaneous implants were inadequate in allowing a long-term seal to develop with the soft tissue, thus increasing vulnerability to the migration of infecting microorganisms.
Collapse
Affiliation(s)
- Dorthyann Isackson
- Orthopaedic Research Laboratory, University of Utah Orthopaedic Center, Salt Lake City, UT 84108, USA
| | | | | |
Collapse
|
17
|
Lin HL, Lin CCK, Ju MS, Liao JD. In vivo impedance evaluation of Au/PI microelectrode with surface modulated by alkanethiolate self-assembled monolayers. Biomed Microdevices 2010; 13:243-53. [PMID: 20972888 DOI: 10.1007/s10544-010-9489-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The goal of this study was to verify that a fully implanted microelectrode with modulated surface may have a reduced rising rate of total impedance and a longer life time. In the previous work, alkanethiolate self-assembled monolayers (SAMs) surface as protein-resistant spacer or cell-repulsive dense-packed spacer has been verified from in vitro experiments. In this study, microelectrodes with the same surface modulation were implanted into the subcutaneous layers of Wistar rats. Nine rats were implanted with the microelectrodes and the total impedance data were measured every 24 h for 2 weeks after implantation. An equivalent electrical circuit model of the electrode-tissue interface was established and parameters were estimated by using an optimization algorithm. Four out of nine rats had manifested acute inflammation reaction and the rests revealed only slight tissue response. Histological examination for the inflammatory group showed fibroblasts, macrophages, and polymorphonuclear leukocytes in adjacent to the electrode contact surface. In the inflammatory group, no significantly difference in total impedance was found in both types of electrodes. However, the trend of total impedance of SAMs-treated electrodes could maintain a steady state value after 1 week. For the non-inflammatory group, both types of electrodes could reduce the impedance value within implanted days. The tissue resistance might be related to the thickness of cells adhered upon the electrode contacts.
Collapse
Affiliation(s)
- Hwa-Li Lin
- Department of Mechanical Engineering, National Cheng Kung University, Tainan, Taiwan, Republic of China
| | | | | | | |
Collapse
|
18
|
Jarrell JD, Dolly B, Morgan JR. Rapid screening, in vitro study of metal oxide and polymer hybrids as delivery coatings for improved soft-tissue integration of implants. J Biomed Mater Res A 2010; 92:1094-104. [PMID: 19301265 DOI: 10.1002/jbm.a.32435] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Metal-organic chemistry allows for molecular mixing and creation of a range of submicron phase-separated structures from normally brittle metal oxides and flexible polymers with improved bioactivity and delivery properties. In this study, we used a high throughput platform to investigate the influence of organic metal oxide doping of polydimethylsiloxane (PDMS) coatings on cellular bioactivity and controlled release of vanadium compared with titanium oxide coatings without additional PDMS. Metal-organic-derived titanium and or vanadium was doped into PDMS and used to form a coating on the bottom of cell culture microplates in the absence of added water, acids, or bases. These hybrid coatings were rapidly screened to establish how titanium and vanadium concentration influences cell proliferation, adhesion, and morphology. We demonstrate that titanium doping of PDMS can be used to improve cell proliferation and adhesion, and that vanadium doping caused a biphasic dose response in proliferation. A 28-day vanadium and titanium elution study indicated that titanium was not released, but the presence of PDMS in coatings increased delivery rates of vanadium compared with titania coatings without polymer. Hybrid coatings of titanium-doped polymers have potential for improving wound healing dynamics, soft-tissue integration of medical implants, and use as controlled delivery vehicles.
Collapse
Affiliation(s)
- John D Jarrell
- Department of Molecular Pharmacology, Physiology, and Biotechnology, Brown University, Providence, Rhode Island, USA.
| | | | | |
Collapse
|
19
|
Cell culture on MEMS platforms: a review. Int J Mol Sci 2009; 10:5411-5441. [PMID: 20054478 PMCID: PMC2802002 DOI: 10.3390/ijms10125411] [Citation(s) in RCA: 108] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2009] [Revised: 12/13/2009] [Accepted: 12/16/2009] [Indexed: 01/09/2023] Open
Abstract
Microfabricated systems provide an excellent platform for the culture of cells, and are an extremely useful tool for the investigation of cellular responses to various stimuli. Advantages offered over traditional methods include cost-effectiveness, controllability, low volume, high resolution, and sensitivity. Both biocompatible and bio-incompatible materials have been developed for use in these applications. Biocompatible materials such as PMMA or PLGA can be used directly for cell culture. However, for bio-incompatible materials such as silicon or PDMS, additional steps need to be taken to render these materials more suitable for cell adhesion and maintenance. This review describes multiple surface modification strategies to improve the biocompatibility of MEMS materials. Basic concepts of cell-biomaterial interactions, such as protein adsorption and cell adhesion are covered. Finally, the applications of these MEMS materials in Tissue Engineering are presented.
Collapse
|
20
|
Eriksson Linsmeier C, Prinz CN, Pettersson LME, Caroff P, Samuelson L, Schouenborg J, Montelius L, Danielsen N. Nanowire biocompatibility in the brain--looking for a needle in a 3D stack. NANO LETTERS 2009; 9:4184-4190. [PMID: 19845389 DOI: 10.1021/nl902413x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We investigated the brain-tissue response to nanowire implantations in the rat striatum after 1, 6, and 12 weeks using immunohistochemistry. The nanowires could be visualized in the scar by confocal microscopy (through the scattered laser light). For the nanowire-implanted animals, there is a significant astrocyte response at week 1 compared to controls. The nanowires are phagocytized by ED1 positive microglia, and some of them are degraded and/or transported away from the brain.
Collapse
|
21
|
Johansson F, Wallman L, Danielsen N, Schouenborg J, Kanje M. Porous silicon as a potential electrode material in a nerve repair setting: Tissue reactions. Acta Biomater 2009; 5:2230-7. [PMID: 19285930 DOI: 10.1016/j.actbio.2009.02.010] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2008] [Accepted: 02/03/2009] [Indexed: 11/25/2022]
Abstract
We compared porous silicon (pSi) with smooth Si as chip-implant surfaces in a nerve regeneration setting. Silicon chips can be used for recording neural activity and are potential nerve interface devices. A silicon chip with one smooth and one porous side inserted into a tube was used to bridge a 5 mm defect in rat sciatic nerve. Six or 12 weeks later, new nerve structures surrounded by a perineurium-like capsule had formed on each side of the chip. The number of regenerated nerve fibers did not differ on either side of the chip as shown by immunostaining for neurofilaments. However, the capsule that had formed in contact with the chip was significantly thinner on the porous side than on the smooth side. Cellular protrusions had formed on the pSi side and the regenerated nerve tissue was found to attach firmly to this surface, while the tissue was hardly attached to the smooth silicon surface. We conclude that a pSi surface, due to its large surface area, diminished inflammatory response and firm adhesion to the tissue, should be a good material for the development of new implantable electronic nerve devices.
Collapse
|
22
|
Kilpeläinen M, Riikonen J, Vlasova M, Huotari A, Lehto V, Salonen J, Herzig K, Järvinen K. In vivo delivery of a peptide, ghrelin antagonist, with mesoporous silicon microparticles. J Control Release 2009; 137:166-70. [DOI: 10.1016/j.jconrel.2009.03.017] [Citation(s) in RCA: 109] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2008] [Revised: 03/24/2009] [Accepted: 03/30/2009] [Indexed: 11/26/2022]
|
23
|
Alvarez SD, Derfus AM, Schwartz MP, Bhatia SN, Sailor MJ. The compatibility of hepatocytes with chemically modified porous silicon with reference to in vitro biosensors. Biomaterials 2009; 30:26-34. [PMID: 18845334 PMCID: PMC2784167 DOI: 10.1016/j.biomaterials.2008.09.005] [Citation(s) in RCA: 129] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2008] [Accepted: 09/04/2008] [Indexed: 01/09/2023]
Abstract
Porous Si is a nanostructured material that is of interest for molecular and cell-based biosensing, drug delivery, and tissue engineering applications. Surface chemistry is an important factor determining the stability of porous Si in aqueous media, its affinity for various biomolecular species, and its compatibility with tissues. In this study, the attachment and viability of a primary cell type to porous Si samples containing various surface chemistries is reported, and the ability of the porous Si films to retain their optical reflectivity properties relevant to molecular biosensing is assessed. Four chemical species grafted to the porous Si surface are studied: silicon oxide (via ozone oxidation), dodecyl (via hydrosilylation with dodecene), undecanoic acid (via hydrosilylation with undecylenic acid), and oligo(ethylene) glycol (via hydrosilylation with undecylenic acid followed by an oligo(ethylene) glycol coupling reaction). Fourier Transform Infrared (FTIR) spectroscopy and contact angle measurements are used to characterize the surface. Adhesion and short-term viability of primary rat hepatocytes on these surfaces, with and without pre-adsorption of collagen type I, are assessed using vital dyes (calcein-AM and ethidium homodimer I). Cell viability on undecanoic acid-terminated porous Si, oxide-terminated porous Si, and oxide-terminated flat (non-porous) Si are monitored by quantification of albumin production over the course of 8 days. The stability of porous Si thin films after 8 days in cell culture is probed by measuring the optical interferometric reflectance spectra. Results show that hepatocytes adhere better to surfaces coated with collagen, and that chemical modification does not exert a deleterious effect on primary rat hepatocytes. The hydrosilylation chemistry greatly improves the stability of porous Si in contact with cultured primary cells while allowing cell coverage levels comparable to standard culture preparations on tissue culture polystyrene.
Collapse
Affiliation(s)
- Sara D. Alvarez
- Department of Chemistry and Biochemistry, University of California, San Diego, 9500 Gilman Drive, La Jolla, California, USA 92093-0358
| | - Austin M. Derfus
- Department of Bioengineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, California, USA 92093
| | - Michael P. Schwartz
- Department of Chemistry and Biochemistry, University of California, San Diego, 9500 Gilman Drive, La Jolla, California, USA 92093-0358
| | - Sangeeta N. Bhatia
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139
| | | |
Collapse
|
24
|
Dahlin L, Johansson F, Lindwall C, Kanje M. Chapter 28 Future Perspective in Peripheral Nerve Reconstruction. INTERNATIONAL REVIEW OF NEUROBIOLOGY 2009; 87:507-30. [DOI: 10.1016/s0074-7742(09)87028-1] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
25
|
Linsmeier CE, Wallman L, Faxius L, Schouenborg J, Bjursten LM, Danielsen N. Soft tissue reactions evoked by implanted gallium phosphide. Biomaterials 2008; 29:4598-604. [DOI: 10.1016/j.biomaterials.2008.08.028] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2008] [Accepted: 08/20/2008] [Indexed: 11/28/2022]
|
26
|
|
27
|
Ainslie KM, Tao SL, Popat KC, Desai TA. In vitro immunogenicity of silicon-based micro- and nanostructured surfaces. ACS NANO 2008; 2:1076-1084. [PMID: 19206506 DOI: 10.1021/nn800071k] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The increasing use of micro- and nanostructured silicon-based devices for in vivo therapeutic or sensing applications highlights the importance of understanding the immunogenicity of these surfaces. Four silicon surfaces (nanoporous, microstructured, nanochanneled, and flat) were studied for their ability to provoke an immune response in human blood derived monocytes. The monocytes were incubated with the surfaces for 48 h and the immunogenicity was evaluated based on the viability, shape factors, and cytokine expression. Free radical oxygen formation was measured at 18 h to elicit a possible mechanism invoking immunogenicity. Although no cytokines were significantly different comparing the response of monocytes on the tissue culture polystyrene surfaces to those on the micropeaked surfaces, on average all cytokines were elevated on the micropeaked surface. The monocytes on the nanoporous surface also displayed an elevated cytokine response, overall, but not to the degree of those on the micropeaked surface. The nanochanneled surface response was similar to that of flat silicon. Overall, the immunogenicity and biocompatibility of flat, nanochanneled, and nanoporous silicon toward human monocytes are approximately equivalent to tissue culture polystyrene.
Collapse
Affiliation(s)
- Kristy M Ainslie
- Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, San Francisco, California 94158, USA
| | | | | | | |
Collapse
|
28
|
Nuss KM, von Rechenberg B. Biocompatibility issues with modern implants in bone - a review for clinical orthopedics. Open Orthop J 2008; 2:66-78. [PMID: 19506701 PMCID: PMC2687115 DOI: 10.2174/1874325000802010066] [Citation(s) in RCA: 77] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2008] [Revised: 03/13/2008] [Accepted: 04/07/2008] [Indexed: 11/22/2022] Open
Abstract
Skeletal defects may result from traumatic, infectious, congenital or neoplastic processes and are considered to be a challenge for reconstructive surgery. Although the autologous bone graft is still the "gold standard", there is continuing demand for bone substitutes because of associated disadvantages, such as limited supply and potential donor side morbidity [1]. This is not only true for indications in orthopedic and craniomaxillofacial surgeries, but also in repairing endodontic defects and in dental implantology.Before clinical use all new bone substitute materials have to be validated for their osseoconductive and - depending on the composition of the material also -inductive ability, as well as for their long-term biocompatibility in bone. Serving this purpose various bone healing models to test osteocompatibility and inflammatory potential of a novel material on one hand and, on the other hand, non-healing osseous defects to assess the healing potential of a bone substitute material have been developed. Sometimes the use of more than one implantation site can be helpful to provide a wide range of information about a new material [2].Important markers for biocompatibility and inflammatory responses are the cell types appearing after the implantation of foreign material. There, especially the role of foreign body giant cells (FBGC) is discussed controversial in the pertinent literature, such that it is not clear whether their presence marks an incompatibility of the biomaterial, or whether it belongs to a normal degradation behavior of modern, resorbable biomaterials.This publication is highlighting the different views currently existing about the function of FBGC that appear in response to biomaterials at the implantation sites. A short overview of the general classes of biomaterials, where FBGC may appear as cellular response, is added for clarity, but may not be complete.
Collapse
Affiliation(s)
| | - Brigitte von Rechenberg
- Address correspondence to this author at the The Musculoskeletal Research Unit (MSRU), Equine Department, Vetsuisse Faculty ZH, University of Zürich, Winterthurerstr. 260, 8057 Zürich, Switzerland; Tel: +41-44-635 8410; Fax: +41-44-635 8917; E-mail:
| |
Collapse
|
29
|
Johansson F, Kanje M, Linsmeier C, Wallman L. The Influence of Porous Silicon on Axonal Outgrowth in Vitro. IEEE Trans Biomed Eng 2008; 55:1447-9. [DOI: 10.1109/tbme.2007.912423] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
30
|
Chang CH, Liao JD, Chen JJJ, Ju MS, Lin CCK. Cell adhesion and related phenomena on the surface-modified Au-deposited nerve microelectrode examined by total impedance measurement and cell detachment tests. NANOTECHNOLOGY 2006; 17:2449-2457. [PMID: 21727489 DOI: 10.1088/0957-4484/17/10/004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
This study investigated alkanethiolate self-assembled monolayers (SAMs) of varied chain lengths adsorbed upon novel Au-coated microelectrodes, of which the surface properties were quantitatively evaluated by surface characterization and 3T3 fibroblast cell adhesion, total impedance and cell detachment tests. Thin-film SAMs adsorbed upon Au/PI/Si provided a hydrophobic or passive surface with increased water contact angle and initial total impedance. From cell adhesion tests, we can observe that the film formed as a dense-packed spacer resulted in incomplete cell sealing of 3T3 cells upon the surface-modified microelectrode. Thus the decrease in cell coverage rate and in the slope in association with total impedance as a function of cell-surface reaction time can be found. To study the adhesion force of a comparable single cell attached upon varied modified surfaces, a cell detachment test using a triangular probe tip of a well defined cantilever was carried out in medium containing fibroblast cells. Overall, both the peak force and the work required to detach a comparable single cell from the anchoring domain corresponded well to the increased length of alkyl chains adsorbed upon Au/PI/Si. Both measurements on the SAM modified surfaces demonstrated much smaller values than those on the pristine Au/PI/Si surface. These results concluded that a cell-repulsive characteristic was clearly formed on the SAM modified microelectrode surface. The non-adhering properties of surface-modified microelectrodes should provide better sensitivity for neuromuscular stimulation as well as for the recording of infinitesimal neural signals in future applications of neural prostheses.
Collapse
Affiliation(s)
- Cheng-Hung Chang
- Institute of Biomedical Engineering, National Cheng Kung University, No. 1, University Road, Tainan 70101, Taiwan
| | | | | | | | | |
Collapse
|
31
|
Friedman H, Stonerock C, Lefaivre J, Yost M. The effect of seprafilm and interceed on capsule formation around silicone discs in a rat model. J INVEST SURG 2005; 17:271-81. [PMID: 15385260 DOI: 10.1080/08941930490502844] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
The insertion of a foreign substance, such as a breast implant into mammalian soft tissues, evokes a wound healing response that culminates in a dense connective-tissue envelope or capsule surrounding the implant. Several biodegradable products, such as Seprafilm (carboxymethylcellulose and hyaluronic acid) and Interceed (oxidized regenerated cellulose), have been demonstrated to inhibit adhesions in abdominal and gynecologic surgery. The ability of these cellulose compounds to inhibit capsule formation was addressed in this investigation. Twenty-eight rats were implanted intermuscularly with either plain silicone discs (10 animals), discs wrapped in Seprafilm (10 animals), or discs covered with Interceed (8 animals). Additional control animals (6 animals) consisted of two that had sham operations, two animals implanted with Seprafilm only, and two more implanted with Interceed only. Animals were sacrificed in pairs at varying time intervals after implantation (2, 4, 8, 12, and 16 wk), and the tissues around the silicone discs were analyzed with light microscopy. Control animals were sacrificed at 8 wk. Both Interceed and Seprafilm slowed the formation of a capsule around the implanted silicone discs as both products were degraded. Evidence of residual material, presumably Seprafilm and Interceed, was seen intracellularly in animals 3 to 4 mo, respectively, after implantation. However, neither material prevented the eventual formation of a fibrous capsule around the silicone discs. The results of this study suggest that encapsulating foreign substances with these types of biodegradable materials will not significantly hinder capsule formation. A more direct attack on the wound healing mechanism may provide a definitive solution for capsule problems with implanted materials.
Collapse
Affiliation(s)
- H Friedman
- Division of Plastic Surgery, Department of Surgery, University of South Carolina School of Medicine, Columbia, South Carolina 29203, USA.
| | | | | | | |
Collapse
|
32
|
Chang CH, Liao JD, Chen JJJ, Ju MS, Lin CCK. Alkanethiolate self-assembled monolayers as functional spacers to resist protein adsorption upon Au-coated nerve microelectrode. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2004; 20:11656-11663. [PMID: 15595795 DOI: 10.1021/la040097t] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Alkanethiolate self-assembled monolayers (SAMs) of varied chain lengths were adsorbed upon Au-coated nerve microelectrodes and employed as protein-resistant spacers. The microelectrode spiraled as a cuff type can be used for restoring motor function via electrical stimulation on the peripheral nerve system; however, an increase of electrode impedance might occur during implantation. In this work, a thin-film SAMs treatment upon Au/polyimide (PI) surface of the microelectrode provided a hydrophobic characteristic, which retarded protein adsorption at the initial stage and subsequent pileup (or thickening) process. The protein-resistant effect exhibited comparable SAMs of different chain lengths adsorbed upon Au/PI surfaces. The increase of electrode impedance as a function of protein deposition time was mainly correlated with the addition of reactance that was associated with the pileup thickness of the deposited protein. Particularly, the SAMs-modified surface was capable to detach a significant portion of the accumulated protein from the protein-deposited SAMs/Au/PI, whereas the protein-deposited layers exhibited firm adhesion upon Au/PI surface. It is therefore very promising to apply thin-film SAMs adsorbed upon Au-coated surface for bioinvasive devices that have the need of functional electrical stimulations or sensing nerve signals during chronic implantation.
Collapse
Affiliation(s)
- Cheng-Hung Chang
- Institute of Biomedical Engineering, Department of Materials Science and Engineering, National Cheng Kung University Hospital, National Cheng Kung University, No. 1, University Road, Tainan 70101, Taiwan
| | | | | | | | | |
Collapse
|