1
|
Buisson J, Zhang X, Zambelli T, Lavalle P, Vautier D, Rabineau M. Reverse Mechanotransduction: Driving Chromatin Compaction to Decompaction Increases Cell Adhesion Strength and Contractility. Nano Lett 2024; 24:4279-4290. [PMID: 38546049 DOI: 10.1021/acs.nanolett.4c00732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
Mechanical extracellular signals elicit chromatin remodeling via the mechanotransduction pathway, thus determining cellular function. However, the reverse pathway is an open question: does chromatin remodeling shape cells, regulating their adhesion strength? With fluidic force microscopy, we can directly measure the adhesion strength of epithelial cells by driving chromatin compaction to decompaction with chromatin remodelers. We observe that chromatin compaction, induced by performing histone acetyltransferase inhibition or ATP depletion, leads to a reduction in nuclear volume, disrupting actin cytoskeleton and focal adhesion assembly, and ultimately decreases in cell adhesion strength and traction force. Conversely, when chromatin decompaction is drived by removing the remodelers, cells recover their original shape, adhesion strength, and traction force. During chromatin decompaction, cells use depolymerized proteins to restore focal adhesion assemblies rather than neo-synthesized cytoskeletal proteins. We conclude that chromatin remodeling shapes cells, regulating adhesion strength through a reverse mechanotransduction pathway from the nucleus to the cell surface involving RhoA activation.
Collapse
Affiliation(s)
- Julie Buisson
- Inserm UMR_S 1121, CNRS EMR 7003, Université de Strasbourg, Biomaterials and Bioengineering, Centre de Recherche en Biomédecine de Strasbourg, Strasbourg F-67000, France
| | - Xinyu Zhang
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich 8092, Switzerland
| | - Tomaso Zambelli
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich 8092, Switzerland
| | - Philippe Lavalle
- Inserm UMR_S 1121, CNRS EMR 7003, Université de Strasbourg, Biomaterials and Bioengineering, Centre de Recherche en Biomédecine de Strasbourg, Strasbourg F-67000, France
- SPARTHA Medical SAS, Centre de Recherche en Biomédecine de Strasbourg, Strasbourg F-67000, France
| | - Dominique Vautier
- Inserm UMR_S 1121, CNRS EMR 7003, Université de Strasbourg, Biomaterials and Bioengineering, Centre de Recherche en Biomédecine de Strasbourg, Strasbourg F-67000, France
| | - Morgane Rabineau
- Inserm UMR_S 1121, CNRS EMR 7003, Université de Strasbourg, Biomaterials and Bioengineering, Centre de Recherche en Biomédecine de Strasbourg, Strasbourg F-67000, France
| |
Collapse
|
2
|
Tufoni C, Battistella A, Luppi S, Boscolo R, Ricci G, Lazzarino M, Andolfi L. Flagellar beating forces of human spermatozoa with different motility behaviors. Reprod Biol Endocrinol 2024; 22:28. [PMID: 38448984 PMCID: PMC10916019 DOI: 10.1186/s12958-024-01197-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 02/13/2024] [Indexed: 03/08/2024] Open
Abstract
BACKGROUND One of the causes of male infertility is associated with altered spermatozoa motility. These sperm features are frequently analyzed by image-based approaches, which, despite allowing the acquisition of crucial parameters to assess sperm motility, they are unable to provide details regarding the flagellar beating forces, which have been neglected until now. RESULTS In this work we exploit Fluidic Force Microscopy to investigate and quantify the forces associated with the flagellar beating frequencies of human spermatozoa. The analysis is performed on two groups divided according to the progressive motility of semen samples, as identified by standard clinical protocols. In the first group, 100% of the spermatozoa swim linearly (100% progressive motility), while, in the other, spermatozoa show both linear and circular motility (identified as 80 - 20% progressive motility). Significant differences in flagellar beating forces between spermatozoa from semen sample with different progressive motility are observed. Particularly, linear motile spermatozoa exhibit forces higher than those with a circular movement. CONCLUSIONS This research can increase our understanding of sperm motility and the role of mechanics in fertilization, which could help us unveil some of the causes of idiopathic male infertility.
Collapse
Affiliation(s)
- Cristina Tufoni
- University of Trieste, Trieste, 34100, Italy
- CNR-Istituto Officina dei Materiali (IOM), SS 14 km 163.5 Area Science Park Basovizza, Trieste, 34149, Italy
- Institute for Maternal and Child Health - IRCCS "Burlo Garofolo", Trieste, Italy
| | - Alice Battistella
- CNR-Istituto Officina dei Materiali (IOM), SS 14 km 163.5 Area Science Park Basovizza, Trieste, 34149, Italy
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
| | - Stefania Luppi
- Institute for Maternal and Child Health - IRCCS "Burlo Garofolo", Trieste, Italy
| | - Rita Boscolo
- Institute for Maternal and Child Health - IRCCS "Burlo Garofolo", Trieste, Italy
| | - Giuseppe Ricci
- Institute for Maternal and Child Health - IRCCS "Burlo Garofolo", Trieste, Italy.
- Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy.
| | - Marco Lazzarino
- CNR-Istituto Officina dei Materiali (IOM), SS 14 km 163.5 Area Science Park Basovizza, Trieste, 34149, Italy
| | - Laura Andolfi
- CNR-Istituto Officina dei Materiali (IOM), SS 14 km 163.5 Area Science Park Basovizza, Trieste, 34149, Italy.
| |
Collapse
|
3
|
Mulder EJ, Moser B, Delgado J, Steinhardt RC, Esser-Kahn AP. Evidence of collective influence in innate sensing using fluidic force microscopy. Front Immunol 2024; 15:1340384. [PMID: 38322261 PMCID: PMC10844469 DOI: 10.3389/fimmu.2024.1340384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 01/05/2024] [Indexed: 02/08/2024] Open
Abstract
The innate immune system initiates early response to infection by sensing molecular patterns of infection through pattern-recognition receptors (PRRs). Previous work on PRR stimulation of macrophages revealed significant heterogeneity in single cell responses, suggesting the importance of individual macrophage stimulation. Current methods either isolate individual macrophages or stimulate a whole culture and measure individual readouts. We probed single cell NF-κB responses to localized stimuli within a naïve culture with Fluidic Force Microscopy (FluidFM). Individual cells stimulated in naïve culture were more sensitive compared to individual cells in uniformly stimulated cultures. In cluster stimulation, NF-κB activation decreased with increased cell density or decreased stimulation time. Our results support the growing body of evidence for cell-to-cell communication in macrophage activation, and limit potential mechanisms. Such a mechanism might be manipulated to tune macrophage sensitivity, and the density-dependent modulation of sensitivity to PRR signals could have relevance to biological situations where macrophage density increases.
Collapse
Affiliation(s)
| | | | | | | | - Aaron P. Esser-Kahn
- Esser-Kahn Lab, Pritzker School of Molecular Engineering, University of Chicago, Chicago, IL, United States
| |
Collapse
|
4
|
Hengsteler J, Kanes KA, Khasanova L, Momotenko D. Beginner's Guide to Micro- and Nanoscale Electrochemical Additive Manufacturing. Annu Rev Anal Chem (Palo Alto Calif) 2023; 16:71-91. [PMID: 37068744 DOI: 10.1146/annurev-anchem-091522-122334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Electrochemical additive manufacturing is an advanced microfabrication technology capable of producing features of almost unlimited geometrical complexity. A unique combination of the capacity to process conductive materials, design freedom, and micro- to nanoscale resolution offered by these electrochemical techniques promises tremendous opportunities for a multitude of future applications spanning microelectronics, sensing, robotics, and energy storage. This review aims to equip readers with the basic principles of electrochemical 3D printing at the small length scale. By describing the basic principles of electrochemical additive manufacturing technology and using the recent advances in the field, this beginner's guide illustrates how controlling the fundamental phenomena that underpin the print process can be used to vary dimensions, morphology, and microstructure of printed structures.
Collapse
Affiliation(s)
- Julian Hengsteler
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Zurich, Switzerland
| | - Karuna Aurel Kanes
- Department of Chemistry, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany;
| | - Liaisan Khasanova
- Department of Chemistry, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany;
| | - Dmitry Momotenko
- Department of Chemistry, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany;
| |
Collapse
|
5
|
Chala N, Zhang X, Zambelli T, Zhang Z, Schneider T, Panozzo D, Poulikakos D, Ferrari A. 4D Force Detection of Cell Adhesion and Contractility. Nano Lett 2023; 23:2467-2475. [PMID: 36975035 PMCID: PMC10103301 DOI: 10.1021/acs.nanolett.2c03733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 03/17/2023] [Indexed: 06/18/2023]
Abstract
Mechanical signals establish two-way communication between mammalian cells and their environment. Cells contacting a surface exert forces via contractility and transmit them at the areas of focal adhesions. External stimuli, such as compressive and pulling forces, typically affect the adhesion-free cell surface. Here, we demonstrate the collaborative employment of Fluidic Force Microscopy and confocal Traction Force Microscopy supported by the Cellogram solver to enable a powerful integrated force probing approach, where controlled vertical forces are applied to the free surface of individual cells, while the concomitant deformations are used to map their transmission to the substrate. Force transmission across human cells is measured with unprecedented temporal and spatial resolution, enabling the investigation of the cellular mechanisms involved in the adaptation, or maladaptation, to external mechanical stimuli. Altogether, the system enables facile and precise force interrogation of individual cells, with the capacity to perform population-based analysis.
Collapse
Affiliation(s)
- Nafsika Chala
- Laboratory
of Thermodynamics in Emerging Technologies, Department of Mechanical
and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092 Zurich, Switzerland
| | - Xinyu Zhang
- Laboratory
of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Gloriastrasse 35, Zurich 8092, Switzerland
| | - Tomaso Zambelli
- Laboratory
of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, Gloriastrasse 35, Zurich 8092, Switzerland
| | - Ziyi Zhang
- Courant
Institute of Mathematical Sciences, New
York University, 5th Avenue 60, New York, New York 10011, United
States
| | - Teseo Schneider
- Department
of Computer Science, University of Victoria, 3800 Finnerty Road, Engineering
& Computer Science Building, Victoria, BC V8P 5C2, Canada
| | - Daniele Panozzo
- Courant
Institute of Mathematical Sciences, New
York University, 5th Avenue 60, New York, New York 10011, United
States
| | - Dimos Poulikakos
- Laboratory
of Thermodynamics in Emerging Technologies, Department of Mechanical
and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092 Zurich, Switzerland
| | - Aldo Ferrari
- Laboratory
of Thermodynamics in Emerging Technologies, Department of Mechanical
and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092 Zurich, Switzerland
- Experimental
Continuum Mechanics, EMPA, Swiss Federal
Laboratories for Material Science and Technologies, Überlandstrasse 129, 8600 Dübendorf, Switzerland
- Institute
for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zürich, Switzerland
| |
Collapse
|
6
|
Battistella A, Andolfi L, Stebel M, Ciubotaru C, Lazzarino M. Investigation on the change of spermatozoa flagellar beating forces before and after capacitation. Biomater Adv 2023; 145:213242. [PMID: 36549152 DOI: 10.1016/j.bioadv.2022.213242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 11/14/2022] [Accepted: 12/09/2022] [Indexed: 12/23/2022]
Abstract
The swimming forces exerted by mammalian spermatozoa during the pathway to the ovary and during the interaction with the oocyte are thought to play a fundamental role in the fertilization of the egg. In particular, a process named capacitation is of key relevance for its success. Capacitation enables spermatozoa to undergo the acrosome reaction and to exhibit different motility called hyperactivation with a change in the sperm cell tail motion from symmetric to a more asymmetric beating, characterized by wider flagellar bending at lower frequencies. Despite several studies about the mechanism that underlies capacitation, no quantitative information is available about the forces associated with sperm motility. Sperm cell motility has been widely studied with digital imaging tools and video microscopy, but these methodologies cannot provide information about the forces exerted by spermatozoa during the motion and the contribution of every single frequency of flagellar beating to the sperm cell movement. For this purpose, fluidic force microscopy was used to trap single swimming spermatozoa allowing to evaluate these parameters. We observe significant differences between capacitated and non-capacitated spermatozoa in terms of force exerted and beating frequencies. The description of the dynamics of this process is of great interest in the field of reproductive medicine. Such information could be useful to clarify unknown causes of male infertility or for the development of novel methods to assess the quality of semen samples.
Collapse
Affiliation(s)
- Alice Battistella
- CNR-IOM, SS 14 km 163.5 Area Science Park Basovizza, 34149 Trieste, Italy.
| | - Laura Andolfi
- CNR-IOM, SS 14 km 163.5 Area Science Park Basovizza, 34149 Trieste, Italy.
| | - Marco Stebel
- University of Trieste, P. le Europa 1, 34100 Trieste, Italy.
| | - Catalin Ciubotaru
- CNR-IOM, SS 14 km 163.5 Area Science Park Basovizza, 34149 Trieste, Italy.
| | - Marco Lazzarino
- CNR-IOM, SS 14 km 163.5 Area Science Park Basovizza, 34149 Trieste, Italy.
| |
Collapse
|
7
|
Apte G, Hirtz M, Nguyen TH. FluidFM-Based Fabrication of Nanopatterns: Promising Surfaces for Platelet Storage Application. ACS Appl Mater Interfaces 2022; 14:24133-24143. [PMID: 35594573 DOI: 10.1021/acsami.2c03459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Platelets are cell fragments from megakaryocytes devoid of the cell nucleus. They are highly sensitive and easily activated by nonphysiological surfaces. Activated platelets have an intrinsic mechanism to release various proteins that participate in multiple pathways, initiating the platelet activation cascade. Surface-induced platelet activation is a challenge encountered during platelet storage, which eventually leads to aggregation of platelets and can thereby result in the degradation of the platelet concentrates. We have previously reported that surface-induced platelet activation can be minimized by either modifying their contact surfaces with polymers or introducing nanogroove patterns underneath the platelets. Here, we investigated the response of platelets to various nanotopographical surfaces printed using fluidic force microscopy (FluidFM). We found that the hemispherical array (grid) and hexagonal tile (hive) structures caused a reduction of surface stiffness, which leads to an inhibition of platelet adhesion. Our results reveal that nanopatterns enable the inhibition of platelet activation on surfaces, thus implying that development in nanotexturing of storage bags can extend the lifetime of platelet concentrates.
Collapse
Affiliation(s)
- Gurunath Apte
- Institute for Bioprocessing and Analytical Measurement Techniques (iba), 37308 Heilbad Heiligenstadt, Germany
- Institute of Nanotechnology (INT) and Karlsruhe Nano Micro Facility (KNMFi), Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Michael Hirtz
- Institute of Nanotechnology (INT) and Karlsruhe Nano Micro Facility (KNMFi), Karlsruhe Institute of Technology, 76131 Karlsruhe, Germany
| | - Thi-Huong Nguyen
- Institute for Bioprocessing and Analytical Measurement Techniques (iba), 37308 Heilbad Heiligenstadt, Germany
- Faculty of Mathematics and Natural Sciences, Technische Universität Ilmenau, 98694 Ilmenau, Germany
| |
Collapse
|
8
|
Pan F, Liu M, Altenried S, Lei M, Yang J, Straub H, Schmahl WW, Maniura-Weber K, Guillaume-Gentil O, Ren Q. Uncoupling bacterial attachment on and detachment from polydimethylsiloxane surfaces through empirical and simulation studies. J Colloid Interface Sci 2022; 622:419-430. [PMID: 35525145 DOI: 10.1016/j.jcis.2022.04.084] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 03/10/2022] [Accepted: 04/13/2022] [Indexed: 10/18/2022]
Abstract
Bacterial infections related to medical devices can cause severe problems, whose solution requires in-depth understanding of the interactions between bacteria and surfaces. This work investigates the influence of surface physicochemistry on bacterial attachment and detachment under flow through both empirical and simulation studies. We employed polydimethylsiloxane (PDMS) substrates having different degrees of crosslinking as the model material and the extended Derjaguin - Landau - Verwey - Overbeek model as the simulation method. Experimentally, the different PDMS materials led to similar numbers of attached bacteria, which can be rationalized by the identical energy barriers simulated between bacteria and the different materials. However, different numbers of residual bacteria after detachment were observed, which was suggested by simulation that the detachment process is determined by the interfacial physicochemistry rather than the mechanical property of a material. This finding is further supported by analyzing the bacteria detachment from PDMS substrates from which non-crosslinked polymer chains had been removed: similar numbers of residual bacteria were found on the extracted PDMS substrates. The knowledge gained in this work can facilitate the projection of bacterial colonization on a given surface.
Collapse
Affiliation(s)
- Fei Pan
- Laboratory for Biointerfaces, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, 9014 St. Gallen, Switzerland
| | - Mengdi Liu
- Laboratory for Biointerfaces, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, 9014 St. Gallen, Switzerland; Department of Earth- and Environmental Sciences, Ludwig Maximilian University of Munich, Theresienstrasse 41, 80333 Munich, Germany
| | - Stefanie Altenried
- Laboratory for Biointerfaces, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, 9014 St. Gallen, Switzerland
| | - Min Lei
- College of Textiles, Donghua University, North Renmin Road 2999, 201620 Shanghai, China
| | - Jiaxin Yang
- Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, CAS, 130022 Changchun, China
| | - Hervé Straub
- Laboratory for Biointerfaces, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, 9014 St. Gallen, Switzerland
| | - Wolfgang W Schmahl
- Department of Earth- and Environmental Sciences, Ludwig Maximilian University of Munich, Theresienstrasse 41, 80333 Munich, Germany
| | - Katharina Maniura-Weber
- Laboratory for Biointerfaces, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, 9014 St. Gallen, Switzerland
| | - Orane Guillaume-Gentil
- Institute of Microbiology, Department of Biology, ETH Zurich, Vladimir-Prelog-Weg 4, 8093 Zurich, Switzerland
| | - Qun Ren
- Laboratory for Biointerfaces, Empa, Swiss Federal Laboratories for Materials Science and Technology, Lerchenfeldstrasse 5, 9014 St. Gallen, Switzerland.
| |
Collapse
|
9
|
Berganza E, Apte G, Vasantham SK, Nguyen TH, Hirtz M. Integration of Biofunctional Molecules into 3D-Printed Polymeric Micro-/Nanostructures. Polymers (Basel) 2022; 14:1327. [PMID: 35406201 DOI: 10.3390/polym14071327] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 03/21/2022] [Accepted: 03/22/2022] [Indexed: 02/07/2023] Open
Abstract
Three-dimensional printing at the micro-/nanoscale represents a new challenge in research and development to achieve direct printing down to nanometre-sized objects. Here, FluidFM, a combination of microfluidics with atomic force microscopy, offers attractive options to fabricate hierarchical polymer structures at different scales. However, little is known about the effect of the substrate on the printed structures and the integration of (bio)functional groups into the polymer inks. In this study, we printed micro-/nanostructures on surfaces with different wetting properties, and integrated molecules with different functional groups (rhodamine as a fluorescent label and biotin as a binding tag for proteins) into the base polymer ink. The substrate wetting properties strongly affected the printing results, in that the lateral feature sizes increased with increasing substrate hydrophilicity. Overall, ink modification only caused minor changes in the stiffness of the printed structures. This shows the generality of the approach, as significant changes in the mechanical properties on chemical functionalization could be confounders in bioapplications. The retained functionality of the obtained structures after UV curing was demonstrated by selective binding of streptavidin to the printed structures. The ability to incorporate binding tags to achieve specific interactions between relevant proteins and the fabricated micro-/nanostructures, without compromising the mechanical properties, paves a way for numerous bio and sensing applications. Additional flexibility is obtained by tuning the substrate properties for feature size control, and the option to obtain functionalized printed structures without post-processing procedures will contribute to the development of 3D printing for biological applications, using FluidFM and similar dispensing techniques.
Collapse
|
10
|
Abstract
The creation of biologically inspired artificial membranes on substrates with custom size and in close proximity to each other not only provides a platform to study biological processes in a simplified manner, but they also constitute building blocks for chemical or biological sensors integrated in microfluidic devices. Scanning probe lithography tools such as dip-pen nanolithography (DPN) have opened a new paradigm in this regard, although they possess some inherent drawbacks like the need to operate in air environment or the limited choice of lipids that can be patterned. In this work, we propose the use of the fluid force microscopy (FluidFM) technology to fabricate biomimetic membranes without losing the multiplexing capability of DPN but gaining flexibility in lipid inks and patterning environment. We shed light on the driving mechanisms of the FluidFM-mediated lithography processes in air and liquid. The obtained results should prompt the creation of more realistic biomimetic membranes with arbitrary complex phospholipid mixtures, cholesterol, and potential functional membrane proteins directly patterned in physiological environment.
Collapse
Affiliation(s)
- Eider Berganza
- Institute of Nanotechnology (INT) & Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Michael Hirtz
- Institute of Nanotechnology (INT) & Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| |
Collapse
|
11
|
Chala N, Moimas S, Giampietro C, Zhang X, Zambelli T, Exarchos V, Nazari-Shafti TZ, Poulikakos D, Ferrari A. Mechanical Fingerprint of Senescence in Endothelial Cells. Nano Lett 2021; 21:4911-4920. [PMID: 34081865 DOI: 10.1021/acs.nanolett.1c00064] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Endothelial senescence entails alterations of the healthy cell phenotype, which accumulate over time and contribute to cardiovascular disease. Mechanical aspects regulating cell adhesion, force generation, and the response to flow contribute to the senescence-associated drift; however, they remain largely unexplored. Here, we exploit force microscopy to resolve variations of the cell anchoring to the substrate and the tractions generated upon aging in the nanonewton (nN) range. Senescent endothelial cells display a multifold increase in the levels of basal adhesion and force generation supported by mature and strong focal adhesions. The enhanced mechanical interaction with the substrate yields static endothelial monolayers that polarize in response to flow but fail the process of coordinated cell shape remodeling and reorientation. The emerging picture indicates that senescence reinforces the local cell interaction with the substrate and may therefore prevent endothelial denudation; however, it compromises the ability to functionally adapt to the local hemodynamic conditions.
Collapse
Affiliation(s)
- Nafsika Chala
- Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092 Zürich, Switzerland
| | - Silvia Moimas
- Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092 Zürich, Switzerland
| | - Costanza Giampietro
- Experimental Continuum Mechanics, EMPA, Swiss Federal Laboratories for Material Science and Technologies, Überlandstrasse 129, 8600 Dübendorf, Switzerland
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zürich, Switzerland
| | - Xinyu Zhang
- Laboratory of Biosensors and Bioelectronics, Department of Information Technology and Electrical Engineering, ETH Zurich, Gloriastrasse 35, 8092Zürich, Switzerland
| | - Tomaso Zambelli
- Laboratory of Biosensors and Bioelectronics, Department of Information Technology and Electrical Engineering, ETH Zurich, Gloriastrasse 35, 8092Zürich, Switzerland
| | - Vasileios Exarchos
- German Heart Center Berlin, Department for Cardiovascular and Thoracic Surgery, Augustenburger Platz 1, 13353 Berlin, Germany
| | - Timo Z Nazari-Shafti
- German Heart Center Berlin, Department for Cardiovascular and Thoracic Surgery, Augustenburger Platz 1, 13353 Berlin, Germany
- Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Center for Regenerative Therapies, Föhrer Strasse 15, 13353 Berlin, Germany
| | - Dimos Poulikakos
- Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092 Zürich, Switzerland
| | - Aldo Ferrari
- Laboratory of Thermodynamics in Emerging Technologies, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, 8092 Zürich, Switzerland
- Experimental Continuum Mechanics, EMPA, Swiss Federal Laboratories for Material Science and Technologies, Überlandstrasse 129, 8600 Dübendorf, Switzerland
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Leonhardstrasse 21, 8092 Zürich, Switzerland
| |
Collapse
|
12
|
Ren W, Xu J, Lian Z, Yu P, Yu H. Modeling and Experimental Study of the Localized Electrochemical Micro Additive Manufacturing Technology Based on the FluidFM. Materials (Basel) 2020; 13:E2783. [PMID: 32575589 PMCID: PMC7345769 DOI: 10.3390/ma13122783] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 06/09/2020] [Accepted: 06/17/2020] [Indexed: 12/02/2022]
Abstract
In this work, the localized electrochemical micro additive manufacturing technology based on the FluidFM (fluidic force microscope) has been introduced to fabricate micro three-dimensional overhang metal structures at sub-micron resolution. It breaks through the localized deposition previously achieved by micro-anode precision movement, and the micro-injection of the electrolyte is achieved in a stable electric field distribution. The structure of electrochemical facilities has been designed and optimized. More importantly, the local electrochemical deposition process has been analyzed with positive source diffusion, and the mathematical modeling has been revealed in the particle conversion process. A mathematical model is proposed for the species flux under the action of pulsed pressure in an innovatively localized liquid feeding process. Besides, the linear structure, bulk structure, complex structure, and large-area structure of the additive manufacturing are analyzed separately. The experimental diameter of the deposited cylinder structure is linearly fitted. The aspect ratio of the structure is greater than 20, the surface roughness value is between 0.1-0.2 μm at the surface of bulk structures, and the abilities are verified for deposition of overhang, hollow complex structures. Moreover, this work verifies the feasibility of 3D overhang array submicron structure additive manufacturing, with the application of pulsed pressure. Furthermore, this technology opens new avenues for the direct fabrication of nano circuit interconnection, tiny sensors, and micro antennas.
Collapse
Affiliation(s)
| | - Jinkai Xu
- Ministry of Education Key Laboratory for Cross-Scale Micro and Nano Manufacturing, Department of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun 130012, China; (W.R.); (Z.L.); (P.Y.)
| | | | | | - Huadong Yu
- Ministry of Education Key Laboratory for Cross-Scale Micro and Nano Manufacturing, Department of Mechanical and Electrical Engineering, Changchun University of Science and Technology, Changchun 130012, China; (W.R.); (Z.L.); (P.Y.)
| |
Collapse
|
13
|
Ercolano G, van Nisselroy C, Merle T, Vörös J, Momotenko D, Koelmans WW, Zambelli T. Additive Manufacturing of Sub-Micron to Sub-mm Metal Structures with Hollow AFM Cantilevers. Micromachines (Basel) 2019; 11:E6. [PMID: 31861400 PMCID: PMC7019283 DOI: 10.3390/mi11010006] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 12/11/2019] [Accepted: 12/12/2019] [Indexed: 12/25/2022]
Abstract
We describe our force-controlled 3D printing method for layer-by-layer additive micromanufacturing (µAM) of metal microstructures. Hollow atomic force microscopy cantilevers are utilized to locally dispense metal ions in a standard 3-electrode electrochemical cell, enabling a confined electroplating reaction. The deflection feedback signal enables the live monitoring of the voxel growth and the consequent automation of the printing protocol in a layer-by-layer fashion for the fabrication of arbitrary-shaped geometries. In a second step, we investigated the effect of the free parameters (aperture diameter, applied pressure, and applied plating potential) on the voxel size, which enabled us to tune the voxel dimensions on-the-fly, as well as to produce objects spanning at least two orders of magnitude in each direction. As a concrete example, we printed two different replicas of Michelangelo's David. Copper was used as metal, but the process can in principle be extended to all metals that are macroscopically electroplated in a standard way.
Collapse
Affiliation(s)
- Giorgio Ercolano
- Exaddon AG, Sägereistrasse 25, 8152 Glattbrugg, Switzerland; (T.M.); (W.W.K.)
| | - Cathelijn van Nisselroy
- Laboratory of Biosensors and Bioelectronics, ETH Zürich, Gloriastrasse 35, 8092 Zurich, Switzerland; (C.v.N.); (J.V.); (D.M.)
| | - Thibaut Merle
- Exaddon AG, Sägereistrasse 25, 8152 Glattbrugg, Switzerland; (T.M.); (W.W.K.)
| | - János Vörös
- Laboratory of Biosensors and Bioelectronics, ETH Zürich, Gloriastrasse 35, 8092 Zurich, Switzerland; (C.v.N.); (J.V.); (D.M.)
| | - Dmitry Momotenko
- Laboratory of Biosensors and Bioelectronics, ETH Zürich, Gloriastrasse 35, 8092 Zurich, Switzerland; (C.v.N.); (J.V.); (D.M.)
| | - Wabe W. Koelmans
- Exaddon AG, Sägereistrasse 25, 8152 Glattbrugg, Switzerland; (T.M.); (W.W.K.)
| | - Tomaso Zambelli
- Laboratory of Biosensors and Bioelectronics, ETH Zürich, Gloriastrasse 35, 8092 Zurich, Switzerland; (C.v.N.); (J.V.); (D.M.)
| |
Collapse
|
14
|
Doll K, Yang I, Fadeeva E, Kommerein N, Szafrański SP, Bei der Wieden G, Greuling A, Winkel A, Chichkov BN, Stumpp NS, Stiesch M. Liquid-Infused Structured Titanium Surfaces: Antiadhesive Mechanism to Repel Streptococcus oralis Biofilms. ACS Appl Mater Interfaces 2019; 11:23026-23038. [PMID: 31173692 DOI: 10.1021/acsami.9b06817] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
To combat implant-associated infections, there is a need for novel materials which effectively inhibit bacterial biofilm formation. In the present study, the antiadhesive properties of titanium surface functionalization based on the "slippery liquid-infused porous surfaces" (SLIPS) principle were demonstrated and the underlying mechanism was analyzed. The immobilized liquid layer was stable over 13 days of continuous flow in an oral flow chamber system. With increasing flow rates, the surface exhibited a significant reduction in attached biofilm of both the oral initial colonizer Streptococcus oralis and an oral multispecies biofilm composed of S. oralis, Actinomyces naeslundii, Veillonella dispar, and Porphyromonas gingivalis. Using single cell force spectroscopy, reduced S. oralis adhesion forces on the lubricant layer could be measured. Gene expression patterns in biofilms on SLIPS, on control surfaces, and expression patterns of planktonic cultures were also compared. For this purpose, the genome of S. oralis strain ATCC 9811 was sequenced using PacBio Sequel technology. Even though biofilm cells showed clear changes in gene expression compared to planktonic cells, no differences could be detected between bacteria on SLIPS and on control surfaces. Therefore, it can be concluded that the ability of liquid-infused titanium to repel S. oralis biofilms is mainly due to weakened bacterial adhesion to the underlying liquid interface.
Collapse
Affiliation(s)
- Katharina Doll
- Department of Prosthetic Dentistry and Biomedical Materials Science , Hannover Medical School , Carl-Neuberg-Strasse 1 , 30625 Hannover , Germany
| | - Ines Yang
- Department of Prosthetic Dentistry and Biomedical Materials Science , Hannover Medical School , Carl-Neuberg-Strasse 1 , 30625 Hannover , Germany
| | - Elena Fadeeva
- Institute of Quantum Optics , Leibniz University of Hannover , Welfengarten 1 , 30167 Hannover , Germany
| | - Nadine Kommerein
- Department of Prosthetic Dentistry and Biomedical Materials Science , Hannover Medical School , Carl-Neuberg-Strasse 1 , 30625 Hannover , Germany
| | - Szymon P Szafrański
- Department of Prosthetic Dentistry and Biomedical Materials Science , Hannover Medical School , Carl-Neuberg-Strasse 1 , 30625 Hannover , Germany
| | - Gesa Bei der Wieden
- Department of Prosthetic Dentistry and Biomedical Materials Science , Hannover Medical School , Carl-Neuberg-Strasse 1 , 30625 Hannover , Germany
| | - Andreas Greuling
- Department of Prosthetic Dentistry and Biomedical Materials Science , Hannover Medical School , Carl-Neuberg-Strasse 1 , 30625 Hannover , Germany
| | - Andreas Winkel
- Department of Prosthetic Dentistry and Biomedical Materials Science , Hannover Medical School , Carl-Neuberg-Strasse 1 , 30625 Hannover , Germany
| | - Boris N Chichkov
- Institute of Quantum Optics , Leibniz University of Hannover , Welfengarten 1 , 30167 Hannover , Germany
| | - Nico S Stumpp
- Department of Prosthetic Dentistry and Biomedical Materials Science , Hannover Medical School , Carl-Neuberg-Strasse 1 , 30625 Hannover , Germany
| | - Meike Stiesch
- Department of Prosthetic Dentistry and Biomedical Materials Science , Hannover Medical School , Carl-Neuberg-Strasse 1 , 30625 Hannover , Germany
| |
Collapse
|
15
|
Sankaran S, Jaatinen L, Brinkmann J, Zambelli T, Vörös J, Jonkheijm P. Cell Adhesion on Dynamic Supramolecular Surfaces Probed by Fluid Force Microscopy-Based Single-Cell Force Spectroscopy. ACS Nano 2017; 11:3867-3874. [PMID: 28319669 PMCID: PMC5406783 DOI: 10.1021/acsnano.7b00161] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Accepted: 03/20/2017] [Indexed: 05/23/2023]
Abstract
Biomimetic and stimuli-responsive cell-material interfaces are actively being developed to study and control various cell-dynamics phenomena. Since cells naturally reside in the highly dynamic and complex environment of the extracellular matrix, attempts are being made to replicate these conditions in synthetic biomaterials. Supramolecular chemistry, dealing with noncovalent interactions, has recently provided possibilities to incorporate such dynamicity and responsiveness in various types of architectures. Using a cucurbit[8]uril-based host-guest system, we have successfully established a dynamic and electrochemically responsive interface for the display of the integrin-specific ligand, Arg-Gly-Asp (RGD), to promote cell adhesion. Due to the weak nature of the noncovalent forces by which the components at the interface are held together, we expected that cell adhesion would also be weaker in comparison to traditional interfaces where ligands are usually immobilized by covalent linkages. To assess the stability and limitations of our noncovalent interfaces, we performed single-cell force spectroscopy studies using fluid force microscopy. This technique enabled us to measure rupture forces of multiple cells that were allowed to adhere for several hours on individual substrates. We found that the rupture forces of cells adhered to both the noncovalent and covalent interfaces were nearly identical for up to several hours. We have analyzed and elucidated the reasons behind this result as a combination of factors including the weak rupture force between linear Arg-Gly-Asp and integrin, high surface density of the ligand, and increase in effective concentration of the supramolecular components under spread cells. These characteristics enable the construction of highly dynamic biointerfaces without compromising cell-adhesive properties.
Collapse
Affiliation(s)
- Shrikrishnan Sankaran
- Bioinspired
Molecular Engineering Laboratory, MIRA Institute for
Biomedical Research and Technical Medicine and Molecular Nanofabrication Group,
MESA+ Institute for Nanotechnology, University
of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Leena Jaatinen
- Department
of Electronics and Communications Engineering, Tampere University of Technology, BioMediTech, Finn-Medi 1 L 4, Biokatu 6, FI-33520 Tampere, Finland
- Laboratory
of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| | - Jenny Brinkmann
- Bioinspired
Molecular Engineering Laboratory, MIRA Institute for
Biomedical Research and Technical Medicine and Molecular Nanofabrication Group,
MESA+ Institute for Nanotechnology, University
of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Tomaso Zambelli
- Laboratory
of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| | - Janos Vörös
- Laboratory
of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| | - Pascal Jonkheijm
- Bioinspired
Molecular Engineering Laboratory, MIRA Institute for
Biomedical Research and Technical Medicine and Molecular Nanofabrication Group,
MESA+ Institute for Nanotechnology, University
of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| |
Collapse
|
16
|
Hirt L, Ihle S, Pan Z, Dorwling-Carter L, Reiser A, Wheeler JM, Spolenak R, Vörös J, Zambelli T. Template-Free 3D Microprinting of Metals Using a Force-Controlled Nanopipette for Layer-by-Layer Electrodeposition. Adv Mater 2016; 28:2311-5. [PMID: 26783090 DOI: 10.1002/adma.201504967] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2015] [Revised: 11/13/2015] [Indexed: 05/24/2023]
Abstract
A novel 3D printing method for voxel-by-voxel metal printing is presented. Hollow atomic force microscopy (AFM) cantilevers are used to locally supply metal ions in an electrochemical cell, enabling a localized electroplating reaction. By exploiting the deflection feedback of these probes, electrochemical 3D metal printing is, for the first time, demonstrated in a layer-by-layer fashion, enabling the fabrication of arbitrary-shaped geometries.
Collapse
Affiliation(s)
- Luca Hirt
- Institute for Biomedical Engineering, Laboratory of Biosensors and Bioelectronics, ETH and University of Zurich, Gloriastrasse 35, CH-8092, Zurich, Switzerland
| | - Stephan Ihle
- Institute for Biomedical Engineering, Laboratory of Biosensors and Bioelectronics, ETH and University of Zurich, Gloriastrasse 35, CH-8092, Zurich, Switzerland
| | - Zhijian Pan
- Institute for Biomedical Engineering, Laboratory of Biosensors and Bioelectronics, ETH and University of Zurich, Gloriastrasse 35, CH-8092, Zurich, Switzerland
| | - Livie Dorwling-Carter
- Institute for Biomedical Engineering, Laboratory of Biosensors and Bioelectronics, ETH and University of Zurich, Gloriastrasse 35, CH-8092, Zurich, Switzerland
| | - Alain Reiser
- Department of Materials, Laboratory for Nanometallurgy, ETH Zurich, Vladimir-Prelog-Weg 5, CH 8093, Zurich, Switzerland
| | - Jeffrey M Wheeler
- Department of Materials, Laboratory for Nanometallurgy, ETH Zurich, Vladimir-Prelog-Weg 5, CH 8093, Zurich, Switzerland
| | - Ralph Spolenak
- Department of Materials, Laboratory for Nanometallurgy, ETH Zurich, Vladimir-Prelog-Weg 5, CH 8093, Zurich, Switzerland
| | - János Vörös
- Institute for Biomedical Engineering, Laboratory of Biosensors and Bioelectronics, ETH and University of Zurich, Gloriastrasse 35, CH-8092, Zurich, Switzerland
| | - Tomaso Zambelli
- Institute for Biomedical Engineering, Laboratory of Biosensors and Bioelectronics, ETH and University of Zurich, Gloriastrasse 35, CH-8092, Zurich, Switzerland
| |
Collapse
|
17
|
Abstract
From its invention in the 1970s, the patch clamp technique is the gold standard in electrophysiology research and drug screening because it is the only tool enabling accurate investigation of voltage-gated ion channels, which are responsible for action potentials. Because of its key role in drug screening, innovation efforts are being made to reduce its complexity toward more automated systems. While some of these new approaches are being adopted in pharmaceutical companies, conventional patch-clamp remains unmatched in fundamental research due to its versatility. Here, we merged the patch clamp and atomic force microscope (AFM) techniques, thus equipping the patch-clamp with the sensitive AFM force control. This was possible using the FluidFM, a force-controlled nanopipette based on microchanneled AFM cantilevers. First, the compatibility of the system with patch-clamp electronics and its ability to record the activity of voltage-gated ion channels in whole-cell configuration was demonstrated with sodium (NaV1.5) channels. Second, we showed the feasibility of simultaneous recording of membrane current and force development during contraction of isolated cardiomyocytes. Force feedback allowed for a gentle and stable contact between AFM tip and cell membrane enabling serial patch clamping and injection without apparent cell damage.
Collapse
Affiliation(s)
- Dario Ossola
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich , Zurich, Switzerland
| | | | | | | | | | | |
Collapse
|