101
|
López-Ortega A, Sáenz de Viteri V, Alves SA, Mendoza G, Fuentes E, Mitran V, Cimpean A, Dan I, Vela A, Bayón R. Multifunctional TiO 2 coatings developed by plasma electrolytic oxidation technique on a Ti20Nb20Zr4Ta alloy for dental applications. Biomater Adv 2022; 138:212875. [PMID: 35913254 DOI: 10.1016/j.bioadv.2022.212875] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 05/13/2022] [Accepted: 05/16/2022] [Indexed: 06/15/2023]
Abstract
A newly developed β-Ti alloy based on the Ti-Nb-Zr-Ta system (Ti20Nb20Zr4Ta) has been subjected to Plasma Electrolytic Oxidation (PEO) treatment to obtain a multifunctional ceramic-like (TiO2) coating with superior tribocorrosion (wear and corrosion) resistance and improved biocompatibility. For this aim, elements such as Ca, P, and Ag NPs have been incorporated into the oxide film to obtain bioactive and biocide properties. The chemical composition and morphology of the TiO2-PEO coating was characterized, and its multifunctionality was addressed by several means, including antibacterial activity assessment, formation of bone-like apatite, metallic ion release evaluation, in vitro cellular response analysis, and corrosion and tribocorrosion tests in artificial saliva. The developed coatings enhanced the corrosion and tribocorrosion resistance of the bare alloy and exhibited antibacterial ability with low cytotoxicity and negligible ion release. Furthermore, they were able to sustain MC3T3-E1 preosteoblast viability/proliferation and osteogenic differentiation. Altogether, the results obtained demonstrate the potential of the TiO2 coating incorporating Ca, P, and Ag NPs to be used for dental applications.
Collapse
Affiliation(s)
- A López-Ortega
- Tekniker, Basque Research and Technology Aliance (BRTA), Eibar, Spain.
| | | | - S A Alves
- Tekniker, Basque Research and Technology Aliance (BRTA), Eibar, Spain
| | - G Mendoza
- Tekniker, Basque Research and Technology Aliance (BRTA), Eibar, Spain
| | - E Fuentes
- Tekniker, Basque Research and Technology Aliance (BRTA), Eibar, Spain
| | - V Mitran
- University of Bucharest, Department of Biochemistry and Molecular Biology, Bucharest, Romania
| | - A Cimpean
- University of Bucharest, Department of Biochemistry and Molecular Biology, Bucharest, Romania
| | - I Dan
- R&D Consulting and Services SRL, Bucharest, Romania
| | - A Vela
- Mugape S.L., Mallabia, Spain
| | - R Bayón
- Tekniker, Basque Research and Technology Aliance (BRTA), Eibar, Spain
| |
Collapse
|
102
|
Ding R, Miller NC, Woeppel KM, Cui XT, Jacobs TDB. Surface Area and Local Curvature: Why Roughness Improves the Bioactivity of Neural Implants. Langmuir 2022; 38:7512-7521. [PMID: 35678760 PMCID: PMC10080668 DOI: 10.1021/acs.langmuir.2c00473] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
While roughening the surface of neural implants has been shown to significantly improve their performance, the mechanism for this improvement is not understood, preventing systematic optimization of surfaces. Specifically, prior work has shown that the cellular response to a surface can be significantly enhanced by coating the implant surface with inorganic nanoparticles and neuroadhesion protein L1, and this improvement occurs even when the surface chemistry is identical between the nanoparticle-coated and uncoated electrodes, suggesting the critical importance of surface topography. Here, we use transmission electron microscopy to characterize the topography of bare and nanoparticle-coated implants across 7 orders of magnitude in size, from the device scale to the atomic scale. The results reveal multiscale roughness, which cannot be adequately described using conventional roughness parameters. Indeed, the topography is nearly identical between the two samples at the smallest scales and also at the largest scales but vastly different in the intermediate scales, especially in the range of 5-100 nm. Using a multiscale topography analysis, we show that the coating causes a 76% increase in the available surface area for contact and an order-of-magnitude increase in local surface curvature at characteristic sizes corresponding to specific biological structures. These are correlated with a 75% increase in bound proteins on the surface and a 134% increase in neurite outgrowth. The present investigation presents a framework for analyzing the scale-dependent topography of medical device-relevant surfaces, and suggests the most critical size scales that determine the biological response to implanted materials.
Collapse
Affiliation(s)
- Ruikang Ding
- Mechanical Engineering & Materials Science, University of Pittsburgh, 3700 O'Hara St., Benedum Hall Room 636, Pittsburgh, Pennsylvania 15261, United States
| | - Nathaniel C Miller
- Mechanical Engineering & Materials Science, University of Pittsburgh, 3700 O'Hara St., Benedum Hall Room 636, Pittsburgh, Pennsylvania 15261, United States
| | - Kevin M Woeppel
- Bioengineering, University of Pittsburgh, 5057 Biomedical Science Tower 3, 3501 Fifth Ave, Pittsburgh, Pennsylvania 15260, United States
- Center for the Neural Basis of Cognition, 4400 Fifth Ave, Suite 115, Pittsburgh, Pennsylvania 15213, United States
| | - Xinyan T Cui
- Bioengineering, University of Pittsburgh, 5057 Biomedical Science Tower 3, 3501 Fifth Ave, Pittsburgh, Pennsylvania 15260, United States
- Center for the Neural Basis of Cognition, 4400 Fifth Ave, Suite 115, Pittsburgh, Pennsylvania 15213, United States
- McGowan Institute for Regenerative Medicine, Pittsburgh, Pennsylvania 15213, United States
| | - Tevis D B Jacobs
- Mechanical Engineering & Materials Science, University of Pittsburgh, 3700 O'Hara St., Benedum Hall Room 636, Pittsburgh, Pennsylvania 15261, United States
| |
Collapse
|
103
|
Reinedahl D, Johansson P, Galli S, Kjellin P, Albrektsson T, Wennerberg A. Review of PEEK implants and biomechanical and immunological responses to a zirconium phosphate nano-coated PEEK, a blasted PEEK, and a turned titanium implant surface. Am J Dent 2022; 35:152-160. [PMID: 35798711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
PURPOSE To investigate the biomechanical and immunological reactions to coated and non-coated blasted PEEK implants in vivo after 12 weeks and review the associated literature. METHODS Two osteotomy sites were performed in each proximal tibia of 10 lop-eared rabbits (n= 4 per rabbit). Each rabbit received a randomly placed (1) blasted zirconium phosphate nano-coated PEEK- (nano-ZrP), (2) blasted PEEK- (PEEK) and (3) titanium implant (Ti) and an empty sham site. At 12 weeks, removal torque of all implants and biological investigation with qPCR was performed. The implant surfaces were analyzed prior to insertion with interferometry, SEM and XPS. RESULTS The interferometry analysis showed that there was no difference in roughness for the uncoated PEEK compared to the ZrP coated PEEK implants. The titanium implants were considerably smoother (Sa= 0.23 µm) than the uncoated Sa= 1.11 µm) and ZrP coated PEEK implants (Sa= 1.12 µm). SEM analysis on the PEEK implants corroborated the interferometry results; no difference in structure between the uncoated vs. the ZrP coated PEEK was visible on the micrometer level. At higher magnifications, the ZrP coating was visible in the SEM as a thin, porous network. All tested implants displayed osseointegration with the highest RTQ for nano-ZrP (18.4 Ncm) followed by PEEK (14.5 Ncm) and Ti (11.5 Ncm). All implants activated the immune system, with elevated macrophage and M2 macrophage qPCR markers at 12 weeks compared to the sham site. CLINICAL SIGNIFICANCE Nano-ZrP coating improves osseointegration of blasted PEEK implants at 12 weeks of follow-up. Osseointegration of titanium, PEEK and nano-ZrP PEEK is not a normal bone healing process, but rather a shield-off mechanism that appears to be regulated by the innate immune system.
Collapse
Affiliation(s)
- David Reinedahl
- Department of Prosthodontics, Institute of Odontology, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden,
| | - Pär Johansson
- Department of Prosthodontics, Institute of Odontology, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden
| | - Silvia Galli
- Department of Prosthodontics, Faculty of Odontology, Malmõ University, Malmõ, Sweden
| | - Per Kjellin
- Promimic AB, AstraZeneca BioVentureHub, Mõlndal, Sweden
| | - Tomas Albrektsson
- Department of Prosthodontics, Faculty of Odontology, Malmõ University, Malmõ, Sweden
| | - Ann Wennerberg
- Department of Prosthodontics, Institute of Odontology, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden
| |
Collapse
|
104
|
Liao B, Xu C, Wang Z, Li W, Liu X, Lu D. Preparation of chitosan-tannic acid coating and its anti-osteoclast and antibacterial activities in titanium implants. J Bone Miner Metab 2022; 40:402-414. [PMID: 35129682 DOI: 10.1007/s00774-022-01309-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Accepted: 01/04/2022] [Indexed: 11/27/2022]
Abstract
INTRODUCTION Bacterial infection and aseptic loosening caused by bone resorption at the implant interface are major clinical complications during bone defect implantation surgery, and surface modification of the implant to address the aforementioned problems has long been a research focus. MATERIALS AND METHODS In this paper, a chitosan (CTS)-tannic acid (TA) colloid coating with a negative charge and excellent hydrophilicity was prepared on a Ti6Al4V (TC4) surface using a layer-by-layer assembly method. The physical properties, anti-osteoclast activity, and antimicrobial activity of the coatings were investigated. RESULTS The findings showed that when the pH value was 5 and the ratio of CTS:TA was 0.8, the carrying rate of TA was the best. Furthermore, the CTS-TA coating had no cytotoxicity on the morphology and proliferation of BMSCs cells and effectively inhibited the differentiation of RAW264.7 cells into osteoclasts and the proliferation of Staphylococcus aureus and Escherichia coli. With the increase in the immersion time of TC4 in CTS-TA colloid solution, the inhibitory effects will also enhance. CONCLUSION Therefore, the preparation of the CTS-TA coating provides a revolutionary technique for implant surface modification to avoid postoperative bacterial infection and aseptic loosening.
Collapse
Affiliation(s)
- Bo Liao
- Key Laboratory for Advanced Technology of Materials of Ministry of Education, Tribology Research Institute, Southwest Jiaotong University, Chengdu, 610031, China
| | - Cheng Xu
- Key Laboratory for Advanced Technology of Materials of Ministry of Education, Tribology Research Institute, Southwest Jiaotong University, Chengdu, 610031, China
| | - Zhenglun Wang
- Key Laboratory for Advanced Technology of Materials of Ministry of Education, Tribology Research Institute, Southwest Jiaotong University, Chengdu, 610031, China
| | - Wei Li
- Key Laboratory for Advanced Technology of Materials of Ministry of Education, Tribology Research Institute, Southwest Jiaotong University, Chengdu, 610031, China.
| | - Xinyu Liu
- Chengdu Advanced Metal Materials Industry Technology Research Institute, Chengdu, 610300, China
| | - Dong Lu
- Chengdu Advanced Metal Materials Industry Technology Research Institute, Chengdu, 610300, China
| |
Collapse
|
105
|
Shi J, Xu L, Qiu D. Effective Antifogging Coating from Hydrophilic/Hydrophobic Polymer Heteronetwork. Adv Sci (Weinh) 2022; 9:e2200072. [PMID: 35285176 PMCID: PMC9109053 DOI: 10.1002/advs.202200072] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 02/21/2022] [Indexed: 05/20/2023]
Abstract
Fogging on optical devices may severely impair vision, resulting in unacceptable adverse consequences. Hydrophilic coatings can prevent surface fogging by instantly facilitating pseudo-film water condensation but suffer from short antifogging duration due to water film thickening with further condensation. Here, an innovative strategy is reported to achieve longer antifogging duration via thickening the robust bonded hydrophilic/hydrophobic polymer heteronetwork coating to enhance its water absorption capacity. The combination of strong interfacial adhesion and hydrophilic/hydrophobic heteronetwork structure is key to this approach, which avoids interfacial failure and swelling-induced wrinkles under typical fogging conditions. The developed antifogging coating exhibits prolonged antifogging durations over a wide temperature range for repetitious usages. Eyeglasses coated with this coating successfully maintained fog-free vision in two typical scenarios. Besides, the coating recipes developed in this study also have potential as underwater glues as they demonstrate strong adhesions to both glass and polymer substrates in wet conditions.
Collapse
Affiliation(s)
- Junhe Shi
- Beijing National Laboratory for Molecular SciencesCAS Research/Education Center for Excellence in Molecular SciencesInstitute of ChemistryChinese Academy of SciencesBeijing100190China
- University of Chinese Academy of SciencesBeijing100049China
| | - Liju Xu
- Beijing National Laboratory for Molecular SciencesCAS Research/Education Center for Excellence in Molecular SciencesInstitute of ChemistryChinese Academy of SciencesBeijing100190China
| | - Dong Qiu
- Beijing National Laboratory for Molecular SciencesCAS Research/Education Center for Excellence in Molecular SciencesInstitute of ChemistryChinese Academy of SciencesBeijing100190China
- University of Chinese Academy of SciencesBeijing100049China
| |
Collapse
|
106
|
Pham DQ, Gangadoo S, Berndt CC, Chapman J, Zhai J, Vasilev K, Truong VK, Ang ASM. Antibacterial Longevity of a Novel Gallium Liquid Metal/Hydroxyapatite Composite Coating Fabricated by Plasma Spray. ACS Appl Mater Interfaces 2022; 14:18974-18988. [PMID: 35416647 DOI: 10.1021/acsami.2c03695] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Hydroxyapatite (HAp)-coated metallic implants are known for their excellent bioactivity and osteoconductivity. However, infections associated with the microstructure of the HAp coatings may lead to implant failures as well as increased morbidity and mortality. This work addresses the concerns about infections by developing novel composite coatings of HAp and gallium liquid metal (GaLM) using atmospheric plasma spray (APS) as the coating technique. Five weight percent Ga was mixed into a commercially supplied HAp powder using an orbital shaker; then, the HAp-Ga particle feedstock was coated onto Ti6Al4V substrates using the APS technique. The X-ray diffraction results indicated that Ga did not form any Ga-related phases in either the HAp-Ga powder or the respective coating. The GaLM filled the pores of the HAp coating presented both on the top surface and within the coating, especially at voids and cracks, to prevent failures of the coating at these locations. The wettability of the surface was changed from hydrophobic for the HAp coating to hydrophilic for the HAp-Ga composite coating. Finally, the HAp-Ga coating presented excellent antibacterial efficacies against both initial attachments and established biofilms generated from methicillin-resistant Staphylococcus aureus and Pseudomonas aeruginosa after 18 h and 7 days of incubation in comparison to the control HAp coating. This study shows that GaLM improves the antibacterial properties of HAp-based coatings without sacrificing the beneficial properties of conventional HAp coatings. Thus, the HAp-Ga APS coating is a viable candidate for antibacterial coatings.
Collapse
Affiliation(s)
- Duy Quang Pham
- ARC Training Centre for Surface Engineering for Advanced Materials (SEAM), Department of Mechanical Engineering & Product Design Engineering, School of Engineering, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| | - Sheeana Gangadoo
- School of Science, STEM College, RMIT University, Melbourne, VIC 3000, Australia
| | - Christopher C Berndt
- ARC Training Centre for Surface Engineering for Advanced Materials (SEAM), Department of Mechanical Engineering & Product Design Engineering, School of Engineering, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| | - James Chapman
- School of Science, STEM College, RMIT University, Melbourne, VIC 3000, Australia
| | - Jiali Zhai
- School of Science, STEM College, RMIT University, Melbourne, VIC 3000, Australia
| | - Krasimir Vasilev
- College of Medicine and Public Health, Flinders University, Bedford Park, SA 5042, Australia
| | - Vi Khanh Truong
- College of Medicine and Public Health, Flinders University, Bedford Park, SA 5042, Australia
| | - Andrew S M Ang
- ARC Training Centre for Surface Engineering for Advanced Materials (SEAM), Department of Mechanical Engineering & Product Design Engineering, School of Engineering, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
| |
Collapse
|
107
|
Moses JC, Mandal BB. Mesoporous Silk-Bioactive Glass Nanocomposites as Drug Eluting Multifunctional Conformal Coatings for Improving Osseointegration and Bactericidal Properties of Metal Implants. ACS Appl Mater Interfaces 2022; 14:14961-14980. [PMID: 35320670 DOI: 10.1021/acsami.2c00093] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Endowing metal implants with multifunctional traits to prevent implant-associated infections and improve osseointegration has become a pivotal facet in orthopedics and dental fixation. Herein, we report the synthesis of mesoporous 70S bioactive glass-silk fibroin nanocomposites inspired by the biomimetic organo-apatites of mineralized collagen. The mesoporous, biomimetic nanocomposites enabled loading of antibiotics (gentamicin and doxycycline) and favored their release in a rapid manner while preserving their bioactivity. Ease in modification of the mesoporous nanocomposites enabled tailoring of 3-(aminopropyl)-triethoxysilane to the silanol network of bioactive glass, which improved the loading capacity of the hydrophobic drug (dexamethasone). The modification favored the slow and sustained release of dexamethasone from the modified mesoporous nanocomposites, which is desired for mediating osteogenesis and immunomodulation. Conformal coatings of these drug-loaded nanocomposites were materialized on stainless-steel implants through a facile electrophoretic deposition (EPD) technique, wherein the deposition yield can be controlled by applied parameters. Antibiotic coatings exhibited antibacterial efficacy with bioactivity retained up to 28 days, while dexamethasone-loaded coatings favored mesenchymal stem cell adhesion and osteoinduction. The immunomodulatory roles were also ascertained, wherein M2 macrophage biasness was favored in dexamethasone-loaded coatings. The versatility of these mesoporous biomimetic nanocomposites guarantee the loading of scenario-specific drugs to aid their local delivery through the conformal EPD coatings developed over metal implants toward improving implant patency.
Collapse
Affiliation(s)
- Joseph Christakiran Moses
- Biomaterials and Tissue Engineering Laboratory, Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| | - Biman B Mandal
- Biomaterials and Tissue Engineering Laboratory, Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
- School of Health Science and Technology, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India
| |
Collapse
|
108
|
Selvamani V, Kadian S, Detwiler DA, Zareei A, Woodhouse I, Qi Z, Peana S, Alcaraz AM, Wang H, Rahimi R. Laser-Assisted Nanotexturing and Silver Immobilization on Titanium Implant Surfaces to Enhance Bone Cell Mineralization and Antimicrobial Properties. Langmuir 2022; 38:4014-4027. [PMID: 35312330 DOI: 10.1021/acs.langmuir.2c00008] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Despite the great advancement and wide use of titanium (Ti) and Ti-based alloys in different orthopedic implants, device-related infections remain the major complication in modern orthopedic and trauma surgery. Most of these infections are often caused by both poor antibacterial and osteoinductive properties of the implant surface. Here, we have demonstrated a facile two-step laser nanotexturing and immobilization of silver onto the titanium implants to improve both cellular integration and antibacterial properties of Ti surfaces. The required threshold laser processing power for effective nanotexturing and osseointegration was systematically determined by the level of osteoblast cells mineralized on the laser nanotextured Ti (LN-Ti) surfaces using a neodymium-doped yttrium aluminum garnet laser (Nd:YAG, wavelength of 1.06 μm). Laser processing powers above 24 W resulted in the formation of hierarchical nanoporous structures (average pore 190 nm) on the Ti surface with a 2.5-fold increase in osseointegration as compared to the pristine Ti surface. Immobilization of silver nanoparticles onto the LN-Ti surface was conducted by dip coating in an aqueous silver ionic solution and subsequently converted to silver nanoparticles (AgNPs) by using a low power laser-assisted photocatalytic reduction process. Structural and surface morphology analysis via XRD and SEM revealed a uniform distribution of Ag and the formation of an AgTi-alloy interface on the Ti surface. The antibacterial efficacy of the LN-Ti with laser immobilized silver (LN-Ti/LI-Ag) was tested against both Gram-positive (Staphylococcus aureus) and Gram-negative (Escherichia coli) bacteria. The LN-Ti/LI-Ag surface was observed to have efficient and stable antimicrobial properties for over 6 days. In addition, it was found that the LN-Ti/LI-Ag maintained a cytocompatibility and bone cell mineralization property similar to the LN-Ti surface. The differential toxicity of the LN-Ti/LI-Ag between bacterial and cellular species qualifies this approach as a promising candidate for novel rapid surface modification of biomedical metal implants.
Collapse
Affiliation(s)
- Vidhya Selvamani
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907-2050, United States
- Birck Nanotechnology Research Center, Purdue University, West Lafayette, Indiana 47907-2050, United States
| | - Sachin Kadian
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907-2050, United States
- Birck Nanotechnology Research Center, Purdue University, West Lafayette, Indiana 47907-2050, United States
| | | | - Amin Zareei
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907-2050, United States
- Birck Nanotechnology Research Center, Purdue University, West Lafayette, Indiana 47907-2050, United States
| | - Ian Woodhouse
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907-2050, United States
- Birck Nanotechnology Research Center, Purdue University, West Lafayette, Indiana 47907-2050, United States
| | - Zhimin Qi
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Samuel Peana
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Alejandro M Alcaraz
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907-2050, United States
| | - Haiyan Wang
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907-2050, United States
- School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907, United States
| | - Rahim Rahimi
- School of Materials Engineering, Purdue University, West Lafayette, Indiana 47907-2050, United States
- Birck Nanotechnology Research Center, Purdue University, West Lafayette, Indiana 47907-2050, United States
| |
Collapse
|
109
|
Wheelis SE, Biguetti CC, Natarajan S, Chandrashekar BL, Arteaga A, Allami JE, Garlet GP, Rodrigues DC. Effects of Dicationic Imidazolium-Based Ionic Liquid Coatings on Oral Osseointegration of Titanium Implants: A Biocompatibility Study in Multiple Rat Demographics. Genes (Basel) 2022; 13:genes13040642. [PMID: 35456448 PMCID: PMC9026960 DOI: 10.3390/genes13040642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 03/20/2022] [Accepted: 03/30/2022] [Indexed: 01/27/2023] Open
Abstract
Dicationic imidazolium-based ionic liquids with amino acid anions, such as IonL-phenylalanine (IonL-Phe), have been proposed as a multifunctional coating for titanium (Ti) dental implants. However, there has been no evaluation of the biocompatibility of these Ti coatings in the oral environment. This study aims to evaluate the effects of IonL-Phe on early healing and osseointegration of Ti in multiple rat demographics. IonL-Phe-coated and uncoated Ti screws were implanted into four demographic groups of rats to represent biological variations that could affect healing: young males (YMs) and females (YFs), ovariectomized (OVXFs) females, and old males (OMs). Samples underwent histopathological and histomorphometric analysis to evaluate healing at 7 and 30 days around IonL-coated and uncoated Ti. The real-time quantitative polymerase chain reaction was also conducted at the 2- and 7-day YM groups to evaluate molecular dynamics of healing while the IonL-Phe was present on the surface. IonL-coated and uncoated implants demonstrated similar histological signs of healing, while coated samples’ differential gene expression of immunological and bone markers was compared with uncoated implants at 2 and 7 days in YMs. While YMs presented suitable osseointegration for both uncoated and IonL-Phe-coated groups, decreased success rate in other demographics resulted from lack of supporting bone in YFs and poor bone quality in OVXFs and OMs. Overall, it was found that IonL-coated samples had increased bone-to-implant contact across all demographic groups. IonL-Phe coating led to successful osseointegration across all animal demographics and presented the potential to prevent failures in scenarios known to be challenged by bacteria.
Collapse
Affiliation(s)
- Sutton E. Wheelis
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (S.E.W.); (C.C.B.); (B.L.C.); (A.A.); (J.E.A.)
| | - Claudia C. Biguetti
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (S.E.W.); (C.C.B.); (B.L.C.); (A.A.); (J.E.A.)
| | - Shruti Natarajan
- Department of Biological Sciences, The University of Texas at Dallas, Richardson, TX 75080, USA;
- Texas A&M College of Dentistry, Dallas, TX 75246, USA
| | - Bhuvana Lakkasetter Chandrashekar
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (S.E.W.); (C.C.B.); (B.L.C.); (A.A.); (J.E.A.)
| | - Alexandra Arteaga
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (S.E.W.); (C.C.B.); (B.L.C.); (A.A.); (J.E.A.)
| | - Jihad El Allami
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (S.E.W.); (C.C.B.); (B.L.C.); (A.A.); (J.E.A.)
| | - Gustavo P. Garlet
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, São Paulo 01000, Brazil;
| | - Danieli C. Rodrigues
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA; (S.E.W.); (C.C.B.); (B.L.C.); (A.A.); (J.E.A.)
- Correspondence:
| |
Collapse
|
110
|
Dalili F, Aghdam RM, Soltani R, Saremi M. Corrosion, mechanical and bioactivity properties of HA-CNT nanocomposite coating on anodized Ti6Al4V alloy. J Mater Sci Mater Med 2022; 33:34. [PMID: 35347447 PMCID: PMC8960600 DOI: 10.1007/s10856-022-06655-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 02/15/2022] [Indexed: 06/14/2023]
Abstract
Hydroxyapatite-carbon nanotubes (HA-CNTs) nanocomposite coating was applied by electrophoretic method on anodized Ti alloy to investigate its stability in simulated body fluid (SBF). The biocoating was characterized by using scanning electron microscope (SEM) for microstructure, X-ray diffraction (XRD) for crystallography. The effect of CNTs concentration on the coating properties was also investigated and found out that CNTs up to 5% has various improving effect on the system. It increased corrosion resistance and adhesion of the coating to the substrate and decreased the number of cracks on the coating. The results of the in vitro test showed that the cell viability increased with increasing the concentration of CNTs to 3 wt.% CNTs. Graphical abstract.
Collapse
Affiliation(s)
- Faezeh Dalili
- School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, P.O. Box: 11155-4563, Tehran, Iran
| | - Rouhollah Mehdinavaz Aghdam
- School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, P.O. Box: 11155-4563, Tehran, Iran.
| | - Reza Soltani
- School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, P.O. Box: 11155-4563, Tehran, Iran
| | - Mohsen Saremi
- School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, P.O. Box: 11155-4563, Tehran, Iran.
| |
Collapse
|
111
|
Lee M, Han SI, Kim C, Velumani S, Han A, Kassiba AH, Castaneda H. ZrO 2/ZnO/TiO 2 Nanocomposite Coatings on Stainless Steel for Improved Corrosion Resistance, Biocompatibility, and Antimicrobial Activity. ACS Appl Mater Interfaces 2022; 14:13801-13811. [PMID: 35261228 DOI: 10.1021/acsami.1c19498] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The ultrathin nanocomposite coatings made of zirconium oxide (ZrO2), zinc oxide (ZnO), and titanium oxide (TiO2) on stainless steel (SS) were prepared by the radio frequency sputtering method, and the effects of the nanocomposite coating on corrosion protection and antibacterial activities of nanocomposite coated SS were investigated. Scanning electron microscopy was conducted to observe surface morphology of nanocomposite coatings with distinct distribution of grains with the formation on SS substrate. From the electrochemical impedance spectroscopy results, ZrO2/ZnO/TiO2 nanocomposite coating showed excellent corrosion protection performance at 37 °C during immersion in simulated body fluid and saliva solution for 12 and 4 weeks, respectively. The impedance of ZrO2/ZnO/TiO2 (40/10/50) nanocomposite coated SS exhibited values about 5 orders of magnitude higher than that of uncoated SS with polarization at the low-frequency region. Cell viability of ZrO2/ZnO/TiO2 nanocomposite coated SS was examined under mouse fibroblasts culture (L929), and it was observed that the nanocomposite coating improves proliferation through effective cellular attachment compared to uncoated SS. From the antimicrobial activity results, ZrO2/ZnO/TiO2 nanocomposite-coated SS showed killing efficiency of 81.2% and 72.4% against Gram-negative Escherichia coli and Gram-positive Staphylococcus aureus, respectively.
Collapse
Affiliation(s)
- Minho Lee
- Department of Materials Science and Engineering, Texas A&M University, 400 Bizzell St., College Station, Texas 77843, United States
- NanoSD, Inc., 11575 Sorrento Valley Rd., Suite 211, San Diego, California 92121, United States
| | - Song-I Han
- Department of Electrical and Computer Engineering, Texas A&M University, 400 Bizzell St., College Station, Texas 77843, United States
| | - Changkyu Kim
- Department of Materials Science and Engineering, Texas A&M University, 400 Bizzell St., College Station, Texas 77843, United States
| | - Subramaniam Velumani
- Department of Electrical Engineering-SEES, CINVESTAV-IPN, Col San Pedro Zacatenco, C.P 07360, Mexico, D.F., Mexico
| | - Arum Han
- Department of Electrical and Computer Engineering, Texas A&M University, 400 Bizzell St., College Station, Texas 77843, United States
| | - Abdel Hadi Kassiba
- Institute of Molecules and Materials of Le Mans UMR-CNRS 6283, Le Mans University, 72085 Le Mans, France
| | - Homero Castaneda
- Department of Materials Science and Engineering, Texas A&M University, 400 Bizzell St., College Station, Texas 77843, United States
| |
Collapse
|
112
|
Wang X, Liu P, Wu Q, Zheng Z, Xie M, Chen G, Yu J, Wang X, Li G, Kaplan D. Sustainable Antibacterial and Anti-Inflammatory Silk Suture with Surface Modification of Combined-Therapy Drugs for Surgical Site Infection. ACS Appl Mater Interfaces 2022; 14:11177-11191. [PMID: 35192338 DOI: 10.1021/acsami.2c00106] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Silk sutures with antibacterial and anti-inflammatory functions were developed for sustained dual-drug delivery to prevent surgical site infections (SSIs). The silk sutures were prepared with core-shell structures braided from degummed silk filaments and then coated with a silk fibroin (SF) layer loaded with berberine (BB) and artemisinin (ART). Both the rapid release of drugs to prevent initial biofilm formation and the following sustained release to maintain effective concentrations for more than 42 days were demonstrated. In vitro assays using human fibroblasts (Hs 865.Sk) demonstrated cell proliferation on the materials, and hemolysis was 2.4 ± 0.8%, lower than that required by ISO 10993-4 standard. The sutures inhibited platelet adhesion and promoted collagen deposition and blood vessel formation. In vivo assessments using Sprague-Dawley (SD) rats indicated that the coating reduced the expression of pro-inflammatory cytokines interleukin-10 (IL-10) and tumor necrosis factor-α (TNF-α), shortening the inflammatory period and promoting angiogenesis. The results demonstrated that these new sutures exhibited stable structures, favorable biocompatibility, and sustainable antibacterial and anti-inflammatory functions with potential for surgical applications.
Collapse
Affiliation(s)
- Xuchen Wang
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China
| | - Peixin Liu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou 215006, China
- Orthopedic Institute, Soochow University, Suzhou 215006, China
| | - Qinting Wu
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China
| | - Zhaozhu Zheng
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China
| | - Maobin Xie
- Department of Biomedical Engineering, School of Basic Medical Sciences, Guangzhou Medical University, Guangzhou 511436, China
| | - Guoqiang Chen
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China
| | - Jia Yu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou 215006, China
- Orthopedic Institute, Soochow University, Suzhou 215006, China
| | - Xiaoqin Wang
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China
| | - Gang Li
- National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou 215123, China
| | - David Kaplan
- Department of Biomedical Engineering, Tufts University, 4 Colby Street, Medford, Massachusetts 02155, United States
| |
Collapse
|
113
|
Browne K, Kuppusamy R, Chen R, Willcox MDP, Walsh WR, Black DS, Kumar N. Bioinspired Polydopamine Coatings Facilitate Attachment of Antimicrobial Peptidomimetics with Broad-Spectrum Antibacterial Activity. Int J Mol Sci 2022; 23:ijms23062952. [PMID: 35328373 PMCID: PMC8948759 DOI: 10.3390/ijms23062952] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 03/04/2022] [Accepted: 03/07/2022] [Indexed: 01/14/2023] Open
Abstract
The prevention and treatment of biofilm-mediated infections remains an unmet clinical need for medical devices. With the increasing prevalence of antibiotic-resistant infections, it is important that novel approaches are developed to prevent biofilms forming on implantable medical devices. This study presents a versatile and simple polydopamine surface coating technique for medical devices, using a new class of antibiotics—antimicrobial peptidomimetics. Their unique mechanism of action primes them for activity against antibiotic-resistant bacteria and makes them suitable for covalent attachment to medical devices. This study assesses the anti-biofilm activity of peptidomimetics, characterises the surface chemistry of peptidomimetic coatings, quantifies the antibacterial activity of coated surfaces and assesses the biocompatibility of these coated materials. X-ray photoelectron spectroscopy and water contact angle measurements were used to confirm the chemical modification of coated surfaces. The antibacterial activity of surfaces was quantified for S. aureus, E. coli and P. aeruginosa, with all peptidomimetic coatings showing the complete eradication of S. aureus on surfaces and variable activity for Gram-negative bacteria. Scanning electron microscopy confirmed the membrane disruption mechanism of peptidomimetic coatings against E. coli. Furthermore, peptidomimetic surfaces did not lyse red blood cells, which suggests these surfaces may be biocompatible with biological fluids such as blood. Overall, this study provides a simple and effective antibacterial coating strategy that can be applied to biomaterials to reduce biofilm-mediated infections.
Collapse
Affiliation(s)
- Katrina Browne
- School of Chemistry, University of New South Wales (UNSW) Sydney, Sydney 2052, Australia; (K.B.); (R.K.); (R.C.)
- Surgical and Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, Prince of Wales Hospital, University of New South Wales (UNSW), Randwick 2031, Australia;
| | - Rajesh Kuppusamy
- School of Chemistry, University of New South Wales (UNSW) Sydney, Sydney 2052, Australia; (K.B.); (R.K.); (R.C.)
- School of Optometry and Vision Science, University of New South Wales (UNSW) Sydney, Sydney 2052, Australia;
| | - Renxun Chen
- School of Chemistry, University of New South Wales (UNSW) Sydney, Sydney 2052, Australia; (K.B.); (R.K.); (R.C.)
| | - Mark D. P. Willcox
- School of Optometry and Vision Science, University of New South Wales (UNSW) Sydney, Sydney 2052, Australia;
| | - William R. Walsh
- Surgical and Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, Prince of Wales Hospital, University of New South Wales (UNSW), Randwick 2031, Australia;
| | - David StC. Black
- School of Chemistry, University of New South Wales (UNSW) Sydney, Sydney 2052, Australia; (K.B.); (R.K.); (R.C.)
- Correspondence: (D.S.B.); (N.K.); Tel.: +61-2-9385-4657 (D.S.B.); +61-2-9385-4698 (N.K.)
| | - Naresh Kumar
- School of Chemistry, University of New South Wales (UNSW) Sydney, Sydney 2052, Australia; (K.B.); (R.K.); (R.C.)
- Correspondence: (D.S.B.); (N.K.); Tel.: +61-2-9385-4657 (D.S.B.); +61-2-9385-4698 (N.K.)
| |
Collapse
|
114
|
Lee DU, Kim DW, Lee SY, Choi DY, Choi SY, Moon KS, Shon MY, Moon MJ. Amino acid-mediated negatively charged surface improve antifouling and tribological characteristics for medical applications. Colloids Surf B Biointerfaces 2022; 211:112314. [PMID: 35033790 DOI: 10.1016/j.colsurfb.2021.112314] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 12/23/2021] [Accepted: 12/30/2021] [Indexed: 11/18/2022]
Abstract
To prevent infections associated with biomedical catheters, various antimicrobial coatings have been investigated. However, those materials do not provide consistent antibacterial effects or biocompatibility, generally, due to degradation of the coating materials, in vivo. Additionally, biomedical catheters must have low surface friction to reduce tribological damage. In this study, we developed an antifouling surface composed of biocompatible amino acids (leucine, taurine, and aspartic acid) on polyimide, via modification using a series of facile immersion steps with waterborne reactions. The naturally derived amino acid could be formed highly biostable amide bonds on the polyimide surface like peptides. The amino acid-modified surface formed a water layer with antifouling performance through the hydrophilic properties of amino acids. Amino acid-mediated modification reduced adhesion up to 84.45% and 94.81% against Escherichia coli and Staphylococcus epidermidis, respectively, and exhibited an excellent prevention to adhesion against the proteins, albumin and fibrinogen. Evaluation of the surface friction of the catheter revealed a dramatic reduction in the tribological force after amino acid modification on polyimide that of 0.81 N to aspartic acid of 0.44 N. These results clearly demonstrate a reduced occurrence of infections, thrombi and tribological damage following the relatively facile surface modification of catheters. The proposed modification method can be used in a continuous manufacturing process via using the same time of modification steps for the easy producing the product. Moreover, the method uses biocompatible naturally derived materials and can be applied to medical equipment that requires biocompatibility and biofunctionality with polyimide surfaces.
Collapse
Affiliation(s)
- Dong Uk Lee
- Department of Industrial Chemistry, Pukyong National University, Busan 48513, Republic of Korea
| | - Dong Won Kim
- Research Institute for Green Energy Convergence Technology, Gyeongsang National University, Jinju, Gyeongnam 52828, Republic of Korea
| | - Seung Yeup Lee
- Department of Applied Bioscience, Dong-A University, Busan 49315, Republic of Korea
| | - Dong Yun Choi
- Biomedical Manufacturing Technology Center, Korea Institute of Industrial Technology, Yeongcheon, Gyeongbuk 38822, Republic of Korea
| | - Seung Yong Choi
- Department of Industrial Chemistry, Pukyong National University, Busan 48513, Republic of Korea
| | - Kyoung-Seok Moon
- Department of Materials Engineering and Convergence Technology, School of materials Science and Engineering, Gyeongsang National University, Jinju, Gyeongnam 52828, Republic of Korea
| | - Min Young Shon
- Department of Industrial Chemistry, Pukyong National University, Busan 48513, Republic of Korea.
| | - Myung Jun Moon
- Department of Industrial Chemistry, Pukyong National University, Busan 48513, Republic of Korea.
| |
Collapse
|
115
|
Li M, Komasa S, Hontsu S, Hashimoto Y, Okazaki J. Structural Characterization and Osseointegrative Properties of Pulsed Laser-Deposited Fluorinated Hydroxyapatite Films on Nano-Zirconia for Implant Applications. Int J Mol Sci 2022; 23:ijms23052416. [PMID: 35269557 PMCID: PMC8910007 DOI: 10.3390/ijms23052416] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 02/18/2022] [Accepted: 02/18/2022] [Indexed: 02/01/2023] Open
Abstract
Standard zirconia implants used in restoration still present problems related to inertness and long-term stability. Various physicochemical approaches have been used to modify the implant surfaces to improve early and late bone-to-implant integration; however, no ideal surface modification has been reported. This study used pulsed laser deposition to deposit a fluorinated hydroxyapatite (FHA) film on a zirconia implant to create a biologically active surface. The film prepared was uniform, dense, and crack-free, and exhibited granular surface droplets; it also presented excellent mechanical strength and favorable biological behavior. The FHA-coated implant was implanted on the femur of Sprague-Dawley rats, and various tests and analyses were performed. Results show that the in vitro initial cell activity on the FHA-coated samples was enhanced. In addition, higher alkaline phosphatase activity and cell mineralization were detected in cells cultured on the FHA-coated groups. Further, the newly formed bone volume of the FHA-coated group was higher than that of the bare micro-adjusted composite nano-zirconia (NANOZR) group. Therefore, the FHA film facilitated osseointegration and may improve the long-term survival rates of dental implants, and could become part of a new treatment technology for implant surfaces, promoting further optimization of NANOZR implant materials.
Collapse
Affiliation(s)
- Min Li
- Department of Removable Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazono-cho, Hirakata 573-1121, Japan; (S.K.); (J.O.)
- Correspondence: ; Tel.: +81-080-3808-2228
| | - Satoshi Komasa
- Department of Removable Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazono-cho, Hirakata 573-1121, Japan; (S.K.); (J.O.)
| | - Shigeki Hontsu
- Department of Biomedical Engineering, Faculty of Biology-Oriented Science and Technology, Kindai University, 930 Nishimitani, Kinokawa 649-6493, Japan;
| | - Yoshiya Hashimoto
- Department of Biomaterials, Osaka Dental University, 8-1 Kuzuhahanazono-cho, Hirakata 573-1121, Japan;
| | - Joji Okazaki
- Department of Removable Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazono-cho, Hirakata 573-1121, Japan; (S.K.); (J.O.)
| |
Collapse
|
116
|
Ziąbka M, Matysiak K, Walczak K, Gajek M, Cholewa-Kowalska K. Modification of TiAlV Alloys with Hybrid Layers Containing Metallic Nanoparticles Obtained by the Sol-Gel Method: Surface and Structural Properties. Int J Mol Sci 2022; 23:ijms23042283. [PMID: 35216397 PMCID: PMC8877359 DOI: 10.3390/ijms23042283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 02/14/2022] [Accepted: 02/17/2022] [Indexed: 12/04/2022] Open
Abstract
The aim of the work was to obtain hybrid coatings containing silver, copper, and zinc nanoparticles on the TiAlV medical alloy via a sol–gel process. The developed layers were designed to bring about a bactericidal and fungicidal effect, as well as for protection against surgical scratches during the implantation of implants used in veterinary medicine. In this work, the authors focused on evaluating the microstructure (SEM + EDS); the structure (XRD, FTIR); and the surface properties, such as wettability, free surface energy, and roughness of layers with various concentrations of metallic nanoparticles (2 and 5 mol %). Our results confirmed that the sol–gel method enables the easy manufacturing of hybrid layers endowed with different porosity values as well as various shapes and sizes of metallic nanoparticles. A higher concentration of nanoparticles was observed on the surface containing 5 mol % of metallic salts. The highest degree of homogeneity was obtained for the layers containing silver nanoparticles. In addition, the silver nanoparticles were round and had the smallest dimensions, even below 20 nm. The FTIR and XRD structural studies confirmed the presence of an organosilicon matrix containing all three types of the metallic particles. We conclude that the higher concentration of nanoparticles influenced the alloy surface parameters.
Collapse
Affiliation(s)
- Magdalena Ziąbka
- Department of Ceramics and Refractories, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, 30-059 Krakow, Poland; (K.M.); (M.G.)
- Correspondence: ; Tel.: +48-012-617-2523
| | - Katarzyna Matysiak
- Department of Ceramics and Refractories, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, 30-059 Krakow, Poland; (K.M.); (M.G.)
| | - Katarzyna Walczak
- Department of Hydrogen Energy, Faculty of Energy and Fuels, AGH University of Science and Technology, 30-059 Krakow, Poland;
| | - Marcin Gajek
- Department of Ceramics and Refractories, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, 30-059 Krakow, Poland; (K.M.); (M.G.)
| | - Katarzyna Cholewa-Kowalska
- Department of Glass Technology and Amorphous Coatings, Faculty of Materials Science and Ceramics, AGH University of Science and Technology, 30-059 Krakow, Poland;
| |
Collapse
|
117
|
Pei J, Zhu S, Liu Y, Song Y, Xue F, Xiong X, Li C. Photodynamic Effect of Riboflavin on Chitosan Coatings and the Application in Pork Preservation. Molecules 2022; 27:molecules27041355. [PMID: 35209144 PMCID: PMC8877613 DOI: 10.3390/molecules27041355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 02/13/2022] [Accepted: 02/14/2022] [Indexed: 11/18/2022]
Abstract
Riboflavin (RF) was considered to be possessed of photoactivity to generate reactive oxygen species (ROS) under ultraviolet (UV) light, which is thought to be a favorable antibacterial candidate. Herein, RF was incorporated into chitosan (CS) coatings and treated under UV with different exposure times (2, 4, and 6 h) to improve the physicochemical and antibacterial properties. The results showed that the light transmittance and antibacterial performance of chitosan coatings gradually increased with the extension of the UV irradiation time. The antibacterial ability of chitosan coatings correlated with the generation of ROS: ∙OH and H2O2, which achieved 1549.08 and 95.48 μg/g, respectively, after 6 h irradiation. Furthermore, the chitosan coatings with UV irradiation also reduced the pH value, total volatile basic nitrogen (TVB-N), ΔE, and total viable counts (TVC) and improved sensory attributes of pork. In conclusion, the UV irradiated chitosan coatings could be used as an environmentally friendly antimicrobial packaging material to effectively delay the spoilage of pork, maintain its sensory quality and prolong its shelf life.
Collapse
Affiliation(s)
- Jiliu Pei
- College of Food Science and Light Industry, Nanjing Tech University, Nanjing 211816, China; (J.P.); (S.Z.); (Y.L.); (Y.S.); (X.X.)
| | - Shengyu Zhu
- College of Food Science and Light Industry, Nanjing Tech University, Nanjing 211816, China; (J.P.); (S.Z.); (Y.L.); (Y.S.); (X.X.)
| | - Yu Liu
- College of Food Science and Light Industry, Nanjing Tech University, Nanjing 211816, China; (J.P.); (S.Z.); (Y.L.); (Y.S.); (X.X.)
| | - Yukang Song
- College of Food Science and Light Industry, Nanjing Tech University, Nanjing 211816, China; (J.P.); (S.Z.); (Y.L.); (Y.S.); (X.X.)
| | - Feng Xue
- School of Pharmacy, Nanjing University of Chinese Medicine, Nanjing 210023, China;
| | - Xiaohui Xiong
- College of Food Science and Light Industry, Nanjing Tech University, Nanjing 211816, China; (J.P.); (S.Z.); (Y.L.); (Y.S.); (X.X.)
| | - Chen Li
- College of Food Science and Light Industry, Nanjing Tech University, Nanjing 211816, China; (J.P.); (S.Z.); (Y.L.); (Y.S.); (X.X.)
- Correspondence: ; Tel.: +86-138-13362715
| |
Collapse
|
118
|
Zuo K, Wang L, Wang Z, Yin Y, Du C, Liu B, Sun L, Li X, Xiao G, Lu Y. Zinc-Doping Induces Evolution of Biocompatible Strontium-Calcium-Phosphate Conversion Coating on Titanium to Improve Antibacterial Property. ACS Appl Mater Interfaces 2022; 14:7690-7705. [PMID: 35114085 DOI: 10.1021/acsami.1c23631] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Implant-associated infections (IAI) remains a common and devastating complication in orthopedic surgery. To reduce the incidence of IAI, implants with intrinsic antibacterial activity have been proposed. The surface functionalization and structure optimization of metallic implants can be achieved by surface modification using the phosphate chemical conversion (PCC) technique. Zinc (Zn) has strong antibacterial behavior toward a broad-spectrum of bacteria. Herein, Zn was incorporated into strontium-calcium-phosphate (SrCaP) coatings on titanium (Ti) via PCC method, and the influence of its doping amount on the phase, microstructure, antibacterial activity, and biocompatibility of the composite coating was researched. The results indicated that traces of Zn doping produced grain refinement of SrCaP coating with no significant effect on its phase and surface properties, while a higher Zn content induced its phase and microstructure transformed into zinc-strontium-phosphate (SrZn2(PO4)2). SrCaP-Zn1 and SrCaP-Zn4 represented trace and high content Zn-doped coatings, respectively, which exhibited a similar bacterial attachment for a short time but showed inhibition of biofilm formation after continuous incubation up to 24 h. The killing rates of SrCaP-Zn1 coating for Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) reached 61.25% and 55.38%, respectively. While that data increased to 83.01% and 71.28% on SrCaP-Zn4 coating due to the more-releasing Zn2+. Furthermore, in vitro culture of MC3T3-E1 cells proved that the Zn-doped coatings also possessed excellent biocompatibility. This study provides a new perception for the phase and microstructural optimization of phosphate coatings on implant surfaces, as well as fabricating promising coatings with excellent biocompatibility and antimicrobial properties against IAI.
Collapse
Affiliation(s)
- Kangqing Zuo
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Jinan 250061, China
- School of Materials Science and Engineering, Shandong University, Jinan, 250061, China
| | - Lili Wang
- Department of Stomatology, The People's Hospital of Zhaoyuan City, Yantai 264500, China
| | - Zhanghan Wang
- Department of Endodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration, Jinan 250012, China
| | - Yixin Yin
- Oral Implantology Center, Ji Nan Stomatological Hospital, Jinan 250001, China
| | - Chunmiao Du
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Jinan 250061, China
- School of Materials Science and Engineering, Shandong University, Jinan, 250061, China
| | - Bing Liu
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Jinan 250061, China
- School of Materials Science and Engineering, Shandong University, Jinan, 250061, China
| | - Lanying Sun
- Oral Implantology Center, Ji Nan Stomatological Hospital, Jinan 250001, China
| | - Xiaoyan Li
- Department of Endodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Laboratory for Dental Materials and Oral Tissue Regeneration, Jinan 250012, China
| | - Guiyong Xiao
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Jinan 250061, China
- School of Materials Science and Engineering, Shandong University, Jinan, 250061, China
| | - Yupeng Lu
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Jinan 250061, China
- School of Materials Science and Engineering, Shandong University, Jinan, 250061, China
| |
Collapse
|
119
|
Jing X, Li X, Jiang Y, Lou J, Liu Z, Ding Q, Han W. Degradable collagen/sodium alginate/polyvinyl butyral high barrier coating with water/oil-resistant in a facile and effective approach. Carbohydr Polym 2022; 278:118962. [PMID: 34973777 DOI: 10.1016/j.carbpol.2021.118962] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 11/12/2021] [Accepted: 11/28/2021] [Indexed: 11/17/2022]
Abstract
Degradable bio-based materials have been widely considered as functional coatings, however, it is a great challenge to fabricate biodegradable coatings with high barrier, water- and oil- resistance. In this work, such coatings were fabricated by using collagen fibers (CF), sodium alginate (SA), and polyvinyl butyral (PVB). CF and SA were mixed evenly and coated on Ca2+ pretreated filter paper. It was mainly due to the electrostatic adsorption between collagen fibers and sodium alginate, and the crosslinking between the adsorption products and Ca2+. By coating PVB solution, the barrier performance was further improved. Notably, the composite exhibited excellent water vapor resistance (48 g/m2·24 h), water resistance (31 g/m2), oil resistance (kit rating: 12/12) and good mechanical properties. This degradable, environmentally friendly, and simple composite paper method has excellent barrier properties, mechanical properties and fluorine-free properties, and will have many applications in the food and packaging fields.
Collapse
Affiliation(s)
- Xin Jing
- State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China
| | - Xia Li
- State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China
| | - Yifei Jiang
- State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China
| | - Jiang Lou
- State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China
| | - Zhuqing Liu
- State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China
| | - Qijun Ding
- State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China.
| | - Wenjia Han
- State Key Laboratory of Biobased Material and Green Papermaking, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, China.
| |
Collapse
|
120
|
Belén F, Gravina AN, Pistonesi MF, Ruso JM, García NA, Prado FD, Messina PV. NIR-Reflective and Hydrophobic Bio-Inspired Nano-Holed Configurations on Titanium Alloy. ACS Appl Mater Interfaces 2022; 14:5843-5855. [PMID: 35048694 DOI: 10.1021/acsami.1c22557] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Near-infrared (NIR) radiation plays an important role in guided external stimulus therapies; its application in bone-related treatments is becoming more and more frequent. Therefore, metallic biomaterials that exhibit properties activated by NIR are promising for further orthopedic procedures. In this work, we present an adapted electroforming approach to attain a biomorphic nano-holed TiO2 coating on Ti6Al4V alloy. Through a precise control of the anodization conditions, structures revealed the formation of localized nano-pores arranged in a periodic assembly. This specific organization provoked higher stability against thermal oxidation and precise hydrophobic wettability behavior according to Cassie-Baxter's model; both characteristics are a prerequisite to ensure a favorable biological response in an implantable structure for guided bone regeneration. In addition, the periodically arranged sub-wavelength-sized unit cell on the metallic-dielectric structure exhibits a peculiar optical response, which results in higher NIR reflectivity. Accordingly, we have proved that this effect enhances the efficiency of the scattering processes and provokes a significant improvement of light confinement producing a spontaneous NIR fluorescence emission. The combination of the already favorable mechanical and biocompatibility properties of Ti6Al4V, along with suitable thermal stability, wetting, and electro-optical behavior, opens a promising path toward strategic bone therapeutic procedures.
Collapse
Affiliation(s)
- Federico Belén
- INQUISUR─CONICET, Department of Chemistry, Universidad Nacional del Sur, CPB B8000 Bahía Blanca, Argentina
| | - A Noel Gravina
- INQUISUR─CONICET, Department of Chemistry, Universidad Nacional del Sur, CPB B8000 Bahía Blanca, Argentina
| | - Marcelo Fabián Pistonesi
- INQUISUR─CONICET, Department of Chemistry, Universidad Nacional del Sur, CPB B8000 Bahía Blanca, Argentina
| | - Juan M Ruso
- Soft Matter and Molecular Biophysics Group, Department of Applied Physics, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain
| | - Nicolás A García
- IFISUR─CONICET, Department of Physics, Universidad Nacional del Sur, CPB B8000 Bahía Blanca, Argentina
| | - Fernando Daniel Prado
- IFISUR─CONICET, Department of Physics, Universidad Nacional del Sur, CPB B8000 Bahía Blanca, Argentina
| | - Paula V Messina
- INQUISUR─CONICET, Department of Chemistry, Universidad Nacional del Sur, CPB B8000 Bahía Blanca, Argentina
| |
Collapse
|
121
|
White DE, Bartley J, Whittington C, Garcia L, Chand K, Turangi C. Pilot study: Post-surgical infections could be related with lack of sharpness in surgical tools. PLoS One 2022; 17:e0261322. [PMID: 35108280 PMCID: PMC8809569 DOI: 10.1371/journal.pone.0261322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 11/30/2021] [Indexed: 11/18/2022] Open
Abstract
Despite rigorous sterilization protocols placed in surgical procedures, there is demonstrated evidence that show patients contract infections while hospitalized. This study aims to investigate the presence of biological materials in osteotome surgical tools after sterilization processes, determine the relationship between lack of sharpness and cross-contamination, and evaluate the influence of materials surface coating as a potential contamination preventive. Three commercially available osteotomes with different surface coatings were studied and submitted to a procedure of bone-cutting cycles. After use, each was sterilized and examined under SEM and EDS. Bone contaminants were detected in each osteotome although the PVD coated osteotome demonstrated significantly less contamination than either the as-supplied or electroless nickel coated one. According to the results, there is an association between blade sharpness and post-sterilization bone contamination. These findings suggest either disposable osteotomes should be used in surgical procedures, or an effective sharpen process should both be established and monitored to minimise post-operative infections.
Collapse
Affiliation(s)
- David E. White
- BioDesign Lab, School of Engineering, Computer and Mathematical Sciences, Auckland University of Technology, Auckland, New Zealand
| | - Jim Bartley
- Department of Surgery, University of Auckland, Auckland, New Zealand
| | - Christopher Whittington
- BioDesign Lab, School of Engineering, Computer and Mathematical Sciences, Auckland University of Technology, Auckland, New Zealand
| | - Lorenzo Garcia
- BioDesign Lab, School of Engineering, Computer and Mathematical Sciences, Auckland University of Technology, Auckland, New Zealand
- * E-mail:
| | - Kaushik Chand
- BioDesign Lab, School of Engineering, Computer and Mathematical Sciences, Auckland University of Technology, Auckland, New Zealand
| | - Celine Turangi
- BioDesign Lab, School of Engineering, Computer and Mathematical Sciences, Auckland University of Technology, Auckland, New Zealand
| |
Collapse
|
122
|
Wei R, Liu K, Zhang K, Fan Y, Lin H, Gao J. Zwitterion-Coated Ultrasmall MnO Nanoparticles Enable Highly Sensitive T1-Weighted Contrast-Enhanced Brain Imaging. ACS Appl Mater Interfaces 2022; 14:3784-3791. [PMID: 35019261 DOI: 10.1021/acsami.1c20617] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
Manganese oxide nanoparticles (NPs) have attracted increasing attention recently as contrast agents (CAs) for magnetic resonance imaging (MRI). However, the clinical translation and popularization of conventional MnO NPs are hampered by their relatively poor imaging performance. Herein, we report the construction of ultrasmall MnO NPs (USMnO) via a one-pot synthetic approach that show a much better capability of T1-weighted contrast enhancement for MRI (r1 = 15.6 ± 0.4 mM-1 s-1 at 0.5 T) than MnCl2 and conventional large-sized MnO NPs (MnO-22). These USMnO are further coated with zwitterionic dopamine sulfonate (ZDS) molecules, which improves their biocompatibility and prevents nonspecific binding of serum albumins. Interestingly, USMnO@ZDS are capable of passing through the blood-brain barrier (BBB), which enables the acquisition of clear images showing brain anatomic structures with T1-weighted contrast-enhanced MRI. Therefore, our USMnO@ZDS could be used as a promising MRI CA for the flexible and accurate diagnosis of brain diseases, which is also instructive for the construction of manganese-based CA with a high MRI performance.
Collapse
Affiliation(s)
- Ruixue Wei
- State Key Laboratory of Physical Chemistry of Solid Surfaces, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, and The Key Laboratory for Chemical Biology of Fujian Province, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
- Department of Cerebrovascular Diseases, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, Henan, China
| | - Kun Liu
- State Key Laboratory of Physical Chemistry of Solid Surfaces, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, and The Key Laboratory for Chemical Biology of Fujian Province, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Ke Zhang
- Department of Interventional Medicine, Center for Interventional Medicine, Guangdong Provincial Engineering Research Center of Molecular Imaging, and Guangdong Provincial Key Laboratory of Biomedical Imaging, The Fifth Affiliated Hospital, Sun Yat-sen University, Zhuhai, Guangdong 519000, China
| | - Yifan Fan
- State Key Laboratory of Physical Chemistry of Solid Surfaces, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, and The Key Laboratory for Chemical Biology of Fujian Province, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Hongyu Lin
- State Key Laboratory of Physical Chemistry of Solid Surfaces, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, and The Key Laboratory for Chemical Biology of Fujian Province, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Jinhao Gao
- State Key Laboratory of Physical Chemistry of Solid Surfaces, The MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, and The Key Laboratory for Chemical Biology of Fujian Province, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| |
Collapse
|
123
|
Farkas E, Tarr R, Gerecsei T, Saftics A, Kovács KD, Stercz B, Domokos J, Peter B, Kurunczi S, Szekacs I, Bonyár A, Bányai A, Fürjes P, Ruszkai-Szaniszló S, Varga M, Szabó B, Ostorházi E, Szabó D, Horvath R. Development and In-Depth Characterization of Bacteria Repellent and Bacteria Adhesive Antibody-Coated Surfaces Using Optical Waveguide Biosensing. Biosensors (Basel) 2022; 12:bios12020056. [PMID: 35200317 PMCID: PMC8869200 DOI: 10.3390/bios12020056] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 01/07/2022] [Accepted: 01/13/2022] [Indexed: 05/10/2023]
Abstract
Bacteria repellent surfaces and antibody-based coatings for bacterial assays have shown a growing demand in the field of biosensors, and have crucial importance in the design of biomedical devices. However, in-depth investigations and comparisons of possible solutions are still missing. The optical waveguide lightmode spectroscopy (OWLS) technique offers label-free, non-invasive, in situ characterization of protein and bacterial adsorption. Moreover, it has excellent flexibility for testing various surface coatings. Here, we describe an OWLS-based method supporting the development of bacteria repellent surfaces and characterize the layer structures and affinities of different antibody-based coatings for bacterial assays. In order to test nonspecific binding blocking agents against bacteria, OWLS chips were coated with bovine serum albumin (BSA), I-block, PAcrAM-g-(PMOXA, NH2, Si), (PAcrAM-P) and PLL-g-PEG (PP) (with different coating temperatures), and subsequent Escherichia coli adhesion was monitored. We found that the best performing blocking agents could inhibit bacterial adhesion from samples with bacteria concentrations of up to 107 cells/mL. Various immobilization methods were applied to graft a wide range of selected antibodies onto the biosensor's surface. Simple physisorption, Mix&Go (AnteoBind) (MG) films, covalently immobilized protein A and avidin-biotin based surface chemistries were all fabricated and tested. The surface adsorbed mass densities of deposited antibodies were determined, and the biosensor;s kinetic data were evaluated to divine the possible orientations of the bacteria-capturing antibodies and determine the rate constants and footprints of the binding events. The development of affinity layers was supported by enzyme-linked immunosorbent assay (ELISA) measurements in order to test the bacteria binding capabilities of the antibodies. The best performance in the biosensor measurements was achieved by employing a polyclonal antibody in combination with protein A-based immobilization and PAcrAM-P blocking of nonspecific binding. Using this setting, a surface sensitivity of 70 cells/mm2 was demonstrated.
Collapse
Affiliation(s)
- Eniko Farkas
- Centre for Energy Research, Nanobiosensorics Laboratory, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (R.T.); (T.G.); (A.S.); (K.D.K.); (B.P.); (S.K.); (I.S.)
| | - Robert Tarr
- Centre for Energy Research, Nanobiosensorics Laboratory, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (R.T.); (T.G.); (A.S.); (K.D.K.); (B.P.); (S.K.); (I.S.)
- Department of Electronics Technology, Faculty of Electrical Engineering and Informatics, Budapest University of Technology and Economics, 1111 Budapest, Hungary;
| | - Tamás Gerecsei
- Centre for Energy Research, Nanobiosensorics Laboratory, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (R.T.); (T.G.); (A.S.); (K.D.K.); (B.P.); (S.K.); (I.S.)
- Department of Biological Physics, Eötvös Loránd University, 1117 Budapest, Hungary
| | - Andras Saftics
- Centre for Energy Research, Nanobiosensorics Laboratory, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (R.T.); (T.G.); (A.S.); (K.D.K.); (B.P.); (S.K.); (I.S.)
| | - Kinga Dóra Kovács
- Centre for Energy Research, Nanobiosensorics Laboratory, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (R.T.); (T.G.); (A.S.); (K.D.K.); (B.P.); (S.K.); (I.S.)
- Department of Biological Physics, Eötvös Loránd University, 1117 Budapest, Hungary
| | - Balazs Stercz
- Institute of Medical Microbiology, Semmelweis University, 1089 Budapest, Hungary; (B.S.); (J.D.); (E.O.); (D.S.)
| | - Judit Domokos
- Institute of Medical Microbiology, Semmelweis University, 1089 Budapest, Hungary; (B.S.); (J.D.); (E.O.); (D.S.)
| | - Beatrix Peter
- Centre for Energy Research, Nanobiosensorics Laboratory, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (R.T.); (T.G.); (A.S.); (K.D.K.); (B.P.); (S.K.); (I.S.)
| | - Sandor Kurunczi
- Centre for Energy Research, Nanobiosensorics Laboratory, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (R.T.); (T.G.); (A.S.); (K.D.K.); (B.P.); (S.K.); (I.S.)
| | - Inna Szekacs
- Centre for Energy Research, Nanobiosensorics Laboratory, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (R.T.); (T.G.); (A.S.); (K.D.K.); (B.P.); (S.K.); (I.S.)
| | - Attila Bonyár
- Department of Electronics Technology, Faculty of Electrical Engineering and Informatics, Budapest University of Technology and Economics, 1111 Budapest, Hungary;
| | - Anita Bányai
- Centre for Energy Research, Microsystems Lab, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (A.B.); (P.F.)
| | - Péter Fürjes
- Centre for Energy Research, Microsystems Lab, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (A.B.); (P.F.)
| | | | - Máté Varga
- 77 Elektronika Ltd., 1116 Budapest, Hungary; (S.R.-S.); (M.V.); (B.S.)
| | - Barnabás Szabó
- 77 Elektronika Ltd., 1116 Budapest, Hungary; (S.R.-S.); (M.V.); (B.S.)
| | - Eszter Ostorházi
- Institute of Medical Microbiology, Semmelweis University, 1089 Budapest, Hungary; (B.S.); (J.D.); (E.O.); (D.S.)
| | - Dóra Szabó
- Institute of Medical Microbiology, Semmelweis University, 1089 Budapest, Hungary; (B.S.); (J.D.); (E.O.); (D.S.)
| | - Robert Horvath
- Centre for Energy Research, Nanobiosensorics Laboratory, Institute of Technical Physics and Materials Science, 1121 Budapest, Hungary; (E.F.); (R.T.); (T.G.); (A.S.); (K.D.K.); (B.P.); (S.K.); (I.S.)
- Correspondence:
| |
Collapse
|
124
|
Fang H, Qi X, Zhou S, Yang S, Hang C, Tian Y, Wang C. High-Efficient Vacuum Ultraviolet-Ozone Assist-Deposited Polydopamine for Poly(lactic- co-glycolic acid)-Coated Pure Zn toward Biodegradable Cardiovascular Stent Applications. ACS Appl Mater Interfaces 2022; 14:3536-3550. [PMID: 34941257 DOI: 10.1021/acsami.1c21567] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Zinc is a prospective metal for biodegradable cardiovascular stent applications, but the excessively released Zn2+ during degradation remains a huge challenge in biocompatibility. Considerable efforts have been made to develop a high-efficient surface modification method, while maintaining adhesion strength, mechanical support, and vascular compatibility. Biomimetic polydopamine (PDA) can adhere to Zn tightly, subsequently achieving robust chemical bonds with poly(lactic-co-glycolic acid) (PLGA) coating. However, the deposition of PDA on Zn depends on the controlled conditions such as a sensitive pH and a long period of time. Herein, we introduce vacuum ultraviolet-ozone (VUV/O3) assist-deposition technology to accelerate the polymerization of PDA on pure Zn, which shortens the process to 40 min at a moderate pH of 8.5 and improves the deposition rate by 1-2 orders of magnitude under sufficient active oxygen species (ROS). Additionally, PLGA/PDA coating enhances the corrosion resistance, and their effective protection maintains the mechanical properties after long-term corrosion. Moreover, the controlled Zn2+ release contributes to the superior in vitro biocompatibility, which inhibits the hemolysis rate and smooth muscle cell (SMC) proliferation. The enhanced endothelial cell (EC) proliferation is promising to promote the re-endothelialization, avoiding in-stent restenosis and neointimal hyperplasia. Such modified Zn might be a viable candidate for the treatment of cardiovascular diseases.
Collapse
Affiliation(s)
- Hui Fang
- State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001, China
| | - Xiaoyun Qi
- State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001, China
| | - Shicheng Zhou
- State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001, China
| | - Shuhan Yang
- State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001, China
| | - Chunjin Hang
- State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001, China
| | - Yanhong Tian
- State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001, China
| | - Chenxi Wang
- State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001, China
| |
Collapse
|
125
|
Tamay DG, Gokyer S, Schmidt J, Vladescu A, Yilgor Huri P, Hasirci V, Hasirci N. Corrosion Resistance and Cytocompatibility of Magnesium-Calcium Alloys Modified with Zinc- or Gallium-Doped Calcium Phosphate Coatings. ACS Appl Mater Interfaces 2022; 14:104-122. [PMID: 34958199 DOI: 10.1021/acsami.1c16307] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
In orthopedic surgery, metals are preferred to support or treat damaged bones due to their high mechanical strength. However, the necessity for a second surgery for implant removal after healing creates problems. Therefore, biodegradable metals, especially magnesium (Mg), gained importance, although their extreme susceptibility to galvanic corrosion limits their applications. The focus of this study was to control the corrosion of Mg and enhance its biocompatibility. For this purpose, surfaces of magnesium-calcium (MgCa1) alloys were modified with calcium phosphate (CaP) or CaP doped with zinc (Zn) or gallium (Ga) via microarc oxidation. The effects of surface modifications on physical, chemical, and mechanical properties and corrosion resistance of the alloys were studied using surface profilometry, goniometry, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), nanoindentation, and electrochemical impedance spectroscopy (EIS). The coating thickness was about 5-8 μm, with grain sizes of 43.1 nm for CaP coating and 28.2 and 58.1 nm for Zn- and Ga-doped coatings, respectively. According to EIS measurements, the capacitive response (Yc) decreased from 11.29 to 8.72 and 0.15 Ω-1 cm-2 sn upon doping with Zn and Ga, respectively. The Ecorr value, which was -1933 mV for CaP-coated samples, was found significantly electropositive at -275 mV for Ga-doped ones. All samples were cytocompatible according to indirect tests. In vitro culture with Saos-2 cells led to changes in the surface compositions of the alloys. The numbers of cells attached to the Zn-doped (2.6 × 104 cells/cm2) and Ga-doped (6.3 × 104 cells/cm2) coatings were higher than that on the surface of the undoped coating (1.0 × 103 cells/cm2). Decreased corrosivity and enhanced cell affinity of the modified MgCa alloys (CaP coated and Zn and Ga doped, with Ga-doped ones having the greatest positive effect) make them novel and promising candidates as biodegradable metallic implant materials for the treatment of bone damages and other orthopedic applications.
Collapse
Affiliation(s)
- Dilara Goksu Tamay
- BIOMATEN, Center of Excellence in Biomaterials and Tissue Engineering, Middle East Technical University (METU), Ankara 06800, Turkey
- Department of Biotechnology, Middle East Technical University (METU), Ankara 06800, Turkey
| | - Seyda Gokyer
- Department of Biomedical Engineering, Ankara University, Ankara 06830, Turkey
| | - Jürgen Schmidt
- Team Leader Electrochemistry, INNOVENT e.V. Technology Development, Prüssingstraße 27b, Jena 07745, Germany
| | - Alina Vladescu
- National Institute of Research and Development for Optoelectronics - INOE 2000, 409 Atomistilor St., Magurele 077125, Romania
- Physical Materials Science and Composite Materials Centre, Research School of Chemistry and Applied Biomedical Sciences, National Research Tomsk Polytechnic University, Lenin Avenue 43, Tomsk 634050, Russia
| | - Pinar Yilgor Huri
- Department of Biomedical Engineering, Ankara University, Ankara 06830, Turkey
| | - Vasif Hasirci
- BIOMATEN, Center of Excellence in Biomaterials and Tissue Engineering, Middle East Technical University (METU), Ankara 06800, Turkey
- Department of Medical Engineering, Acibadem Mehmet Ali Aydinlar University, Istanbul 34684, Turkey
- Biomaterials Center, Acibadem Mehmet Ali Aydinlar University, Istanbul 34684, Turkey
| | - Nesrin Hasirci
- BIOMATEN, Center of Excellence in Biomaterials and Tissue Engineering, Middle East Technical University (METU), Ankara 06800, Turkey
- Department of Biotechnology, Middle East Technical University (METU), Ankara 06800, Turkey
- Department of Chemistry, Middle East Technical University, Ankara 06800, Turkey
- Tissue Engineering and Biomaterial Research Center, Near East University, 99138 Nicosia, TRNC, Mersin 10, Turkey
| |
Collapse
|
126
|
Wright T, Vlok M, Shapira T, Olmstead AD, Jean F, Wolf MO. Photodynamic and Contact Killing Polymeric Fabric Coating for Bacteria and SARS-CoV-2. ACS Appl Mater Interfaces 2022; 14:49-56. [PMID: 34978405 PMCID: PMC8751017 DOI: 10.1021/acsami.1c14178] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Accepted: 11/30/2021] [Indexed: 05/13/2023]
Abstract
The development of low-cost, non-toxic, scalable antimicrobial textiles is needed to address the spread of deadly pathogens. Here, we report a polysiloxane textile coating that possesses two modes of antimicrobial inactivation, passive contact inactivation through amine/imine functionalities and active photodynamic inactivation through the generation of reactive oxygen species (ROS). This material can be coated and cross-linked onto natural and synthetic textiles through a simple soak procedure, followed by UV cure to afford materials exhibiting no aqueous leaching and only minimal leaching in organic solvents. This coating minimally impacts the mechanical properties of the fabric while also imparting hydrophobicity. Passive inactivation of Escherichia coli (E. coli) and methicillin-resistant Staphylococcus aureus (MRSA) is achieved with >98% inactivation after 24 h, with a 23× and 3× inactivation rate increase against E. coli and MRSA, respectively, when green light is used to generate ROS. Up to 90% decrease in the infectivity of SARS-CoV-2 after 2 h of irradiated incubation with the material is demonstrated. These results show that modifying textiles with dual-functional polymers results in robust and highly antimicrobial materials that are expected to find widespread use in combating the spread of deadly pathogens.
Collapse
Affiliation(s)
- Taylor Wright
- Department
of Chemistry, University of British Columbia, 2036 Main Mall, Vancouver BC V6T 1Z1, Canada
| | - Marli Vlok
- Department
of Biochemistry & Molecular Biology, University of British Columbia, 2350 Health Sciences Mall, Vancouver BC V6T 1Z3, Canada
| | - Tirosh Shapira
- Life
Sciences Institute, Department of Microbiology and Immunology, University of British Columbia, Vancouver BC V6T 1Z3, Canada
| | - Andrea D. Olmstead
- Life
Sciences Institute, Department of Microbiology and Immunology, University of British Columbia, Vancouver BC V6T 1Z3, Canada
| | - François Jean
- Life
Sciences Institute, Department of Microbiology and Immunology, University of British Columbia, Vancouver BC V6T 1Z3, Canada
| | - Michael O. Wolf
- Department
of Chemistry, University of British Columbia, 2036 Main Mall, Vancouver BC V6T 1Z1, Canada
| |
Collapse
|
127
|
Bai Y, Wang L, Zhao L, Lingling E, Yang S, Jia S, Wen N. Antibacterial and Antioxidant Effects of Magnesium Alloy on Titanium Dental Implants. Comput Math Methods Med 2022; 2022:6537676. [PMID: 35035523 PMCID: PMC8758302 DOI: 10.1155/2022/6537676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Accepted: 12/07/2021] [Indexed: 11/18/2022]
Abstract
OBJECTIVES In this study, a new type of dental implant by covering the surface of the titanium (Ti) implant with zinc-magnesium (Zn-Mg) alloy was designed, to study the antibacterial and antioxidant effects of Mg alloy on titanium (Ti) implants in oral implant restoration. METHODS Human gingival fibroblasts (HGFs), S. sanguinis, and F. nucleatum bacteria were used to detect the bioactivity and antibacterial properties of Mg alloy-coated Ti implants. In addition, B6/J mice implanted with different materials were used to further detect their antibacterial and antioxidant properties. RESULTS The results showed that Mg alloy could better promote the adhesion and proliferation and improve the alkaline phosphatase (ALP) activity of HGFs, which contributed to better improved stability of implant osseointegration. In addition, Mg alloy could better inhibit the proliferation of S. sanguinis, while no significant difference was found in the proliferation of F. nucleatum between the two implants. In the mouse model, the peripheral inflammatory reaction and oxidative stress of the Mg alloy implant were significantly lower than those of the Ti alloy implant. CONCLUSIONS Zn-Mg alloy-coated Ti implants could better inhibit the growth of Gram-positive bacteria in the oral cavity, inhibit oxidative stress, and facilitate the proliferation activity of HGFs and the potential of osteoblast differentiation, thus, better increasing the stability of implant osseointegration.
Collapse
Affiliation(s)
- Yang Bai
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Lin Wang
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Lisheng Zhao
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - E. Lingling
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Shuo Yang
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Shunyi Jia
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Ning Wen
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
| |
Collapse
|
128
|
Gadallah MA, Darwish RM, Alshimy AM, Gepreel MA, Marei MK. Biomimetic Coating of Titanium Surface Using Bioactive Glass Nanoparticles. Int J Oral Maxillofac Implants 2022; 37:86-97. [PMID: 35235625 DOI: 10.11607/jomi.9156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
PURPOSE The aim of this study was to coat titanium substrate with bioactive glass nanoparticles and characterize the deposited surface coat. MATERIALS AND METHODS Amorphous bioglass nanoparticles < 20 nm in diameter were prepared using a modified sol-gel technique followed by a ball-milling process. The prepared nanoparticles were used to coat airborne particle-abraded titanium disks. The in vitro bioactivity of the bioglass nanopowder was confirmed using simulated body fluid. Coated surfaces were characterized in terms of microstructure, composition, thickness, phase structure, surface roughness, wettability, and tissue behavior in a rabbit model. RESULTS Bioglass nanoparticles showed apatite formation under a scanning electron microscope (SEM) after 5 days, confirming that bioactivity was enhanced with increasing degradation rate for up to 2 weeks. An optimized deposition technique and heat-treatment process produced a homogenous coating with a uniform thickness of 32 to 39 μm. Chemical analysis confirmed the presence of silicon and calcium on the coated disks. Amorphous coated surfaces exhibited porous nano/microroughness with microcracks and super-hydrophilicity. The interface of the coated disks with subcutaneous tissue revealed good tissue adhesion, high cellular activity, and rich vascularization, with multinucleated cells in the microenvironment surrounding the coat, as confirmed using histomorphometric analysis. CONCLUSION The results of this study show that it is feasible to coat titanium surfaces with bioactive glass nanoparticles with super-hydrophilicity and high biologic activity. These particles may promote the regenerative environment around dental implants.
Collapse
|
129
|
Pantulap U, Arango-Ospina M, Boccaccini AR. Bioactive glasses incorporating less-common ions to improve biological and physical properties. J Mater Sci Mater Med 2021; 33:3. [PMID: 34940923 PMCID: PMC8702415 DOI: 10.1007/s10856-021-06626-3] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Accepted: 11/07/2021] [Indexed: 05/29/2023]
Abstract
Bioactive glasses (BGs) have been a focus of research for over five decades for several biomedical applications. Although their use in bone substitution and bone tissue regeneration has gained important attention, recent developments have also seen the expansion of BG applications to the field of soft tissue engineering. Hard and soft tissue repair therapies can benefit from the biological activity of metallic ions released from BGs. These metallic ions are incorporated in the BG network not only for their biological therapeutic effects but also in many cases for influencing the structure and processability of the glass and to impart extra functional properties. The "classical" elements in silicate BG compositions are silicon (Si), phosphorous (P), calcium (Ca), sodium (Na), and potassium (K). In addition, other well-recognized biologically active ions have been incorporated in BGs to provide osteogenic, angiogenic, anti-inflammatory, and antibacterial effects such as zinc (Zn), magnesium (Mg), silver (Ag), strontium (Sr), gallium (Ga), fluorine (F), iron (Fe), cobalt (Co), boron (B), lithium (Li), titanium (Ti), and copper (Cu). More recently, rare earth and other elements considered less common or, some of them, even "exotic" for biomedical applications, have found room as doping elements in BGs to enhance their biological and physical properties. For example, barium (Ba), bismuth (Bi), chlorine (Cl), chromium (Cr), dysprosium (Dy), europium (Eu), gadolinium (Gd), ytterbium (Yb), thulium (Tm), germanium (Ge), gold (Au), holmium (Ho), iodine (I), lanthanum (La), manganese (Mn), molybdenum (Mo), nickel (Ni), niobium (Nb), nitrogen (N), palladium (Pd), rubidium (Rb), samarium (Sm), selenium (Se), tantalum (Ta), tellurium (Te), terbium (Tb), erbium (Er), tin (Sn), tungsten (W), vanadium (V), yttrium (Y) as well as zirconium (Zr) have been included in BGs. These ions have been found to be particularly interesting for enhancing the biological performance of doped BGs in novel compositions for tissue repair (both hard and soft tissue) and for providing, in some cases, extra functionalities to the BG, for example fluorescence, luminescence, radiation shielding, anti-inflammatory, and antibacterial properties. This review summarizes the influence of incorporating such less-common elements in BGs with focus on tissue engineering applications, usually exploiting the bioactivity of the BG in combination with other functional properties imparted by the presence of the added elements.
Collapse
Affiliation(s)
- Usanee Pantulap
- Department of Materials Science and Engineering, Institute of Biomaterials, University of Erlangen-Nuremberg, 91058, Erlangen, Germany
| | - Marcela Arango-Ospina
- Department of Materials Science and Engineering, Institute of Biomaterials, University of Erlangen-Nuremberg, 91058, Erlangen, Germany
| | - Aldo R Boccaccini
- Department of Materials Science and Engineering, Institute of Biomaterials, University of Erlangen-Nuremberg, 91058, Erlangen, Germany.
| |
Collapse
|
130
|
Özcan S, Çiftçioğlu M. Enhanced model protein adsorption of nanoparticulate hydroxyapatite thin films on silk sericin and fibroin surfaces. J Mater Sci Mater Med 2021; 33:6. [PMID: 34951004 PMCID: PMC8702503 DOI: 10.1007/s10856-021-06632-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Accepted: 12/03/2021] [Indexed: 06/01/2023]
Abstract
Hydroxyapatite coated metallic implants favorably combine the required biocompatibility with the mechanical properties. As an alternative to the industrial coating method of plasma spraying with inherently potential deleterious effects, sol-gel methods have attracted much attention. In this study, the effects of intermediate silk fibroin and silk sericin layers on the protein adsorption capacity of hydroxyapatite films formed by a particulate sol-gel method were determined experimentally. The preparation of the layered silk protein/hydroxyapatite structures on glass substrates, and the effects of the underlying silk proteins on the topography of the hydroxyapatite coatings were described. The topography of the hydroxyapatite layer fabricated on the silk sericin was such that the hydroxyapatite particles were oriented forming an oriented crystalline surface. The model protein (bovine serum albumin) adsorption increased to 2.62 µg/cm2 on the latter surface as compared to 1.37 µg/cm2 of hydroxyapatite on glass without an intermediate silk sericin layer. The BSA adsorption on glass (blank), glass/c-HAp, glass/m-HAp, glass/sericin/c-HAp, and glass/sericin/m-HAp substrates, reported as decrease in BSA concentration versus contact time.
Collapse
Affiliation(s)
- Selçuk Özcan
- Department of Industrial Engineering, Bilecik Şeyh Edebali University, Bilecik, Turkey.
| | - Muhsin Çiftçioğlu
- Department of Chemical Engineering, Izmir Institute of Technology, Urla, Izmir, Turkey
| |
Collapse
|
131
|
Toop N, Gifford C, Motiei-Langroudi R, Farzadi A, Boulter D, Forghani R, Farhadi HF. Can activated titanium interbody cages accelerate or enhance spinal fusion? a review of the literature and a design for clinical trials. J Mater Sci Mater Med 2021; 33:1. [PMID: 34921610 PMCID: PMC8684547 DOI: 10.1007/s10856-021-06628-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Accepted: 11/16/2021] [Indexed: 06/14/2023]
Abstract
While spinal interbody cage options have proliferated in the past decade, relatively little work has been done to explore the comparative potential of biomaterial technologies in promoting stable fusion. Innovations such as micro-etching and nano-architectural designs have shown purported benefits in in vitro studies, but lack clinical data describing their optimal implementation. Here, we critically assess the pre-clinical data supportive of various commercially available interbody cage biomaterial, topographical, and structural designs. We describe in detail the osteointegrative and osteoconductive benefits conferred by these modifications with a focus on polyetheretherketone (PEEK) and titanium (Ti) interbody implants. Further, we describe the rationale and design for two randomized controlled trials, which aim to address the paucity of clinical data available by comparing interbody fusion outcomes between either PEEK or activated Ti lumbar interbody cages. Utilizing dual-energy computed tomography (DECT), these studies will evaluate the relative implant-bone integration and fusion rates achieved by either micro-etched Ti or standard PEEK interbody devices. Taken together, greater understanding of the relative osseointegration profile at the implant-bone interface of cages with distinct topographies will be crucial in guiding the rational design of further studies and innovations.
Collapse
Affiliation(s)
- Nathaniel Toop
- Departments of Neurological Surgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Connor Gifford
- Departments of Neurological Surgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | | | - Arghavan Farzadi
- Departments of Neurological Surgery, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Daniel Boulter
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Reza Forghani
- Department of Radiology, McGill University, Montreal, QC, Canada
| | - H Francis Farhadi
- Department of Neurosurgery, College of Medicine, University of Kentucky, Lexington, KY, USA.
| |
Collapse
|
132
|
Lin EMJ, Lay CL, Subramanian GS, Tan WS, Leong SSJ, Moh LCH, Lim K. Control Release Coating for Urinary Catheters with Enhanced Released Profile for Sustained Antimicrobial Protection. ACS Appl Mater Interfaces 2021; 13:59263-59274. [PMID: 34846837 DOI: 10.1021/acsami.1c17697] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Catheter-associated urinary tract infections (CAUTIs) are common and pose significant costs to healthcare systems. To date, this problem is largely unsolved as commercially available antimicrobial catheters are still lacking in functionality and performance. A prior study by Lim et al. ( Biotechnol. Bioeng. 2018, 115 (8), 2000-2012) reported the development of a novel anhydrous polycaprolactone (PCL) polymer formulation with controlled-release functionality for antimicrobial peptides. In this follow-up study, we developed an improved antimicrobial peptide (AMP)-impregnated poly(ethylene glycol) (PEG)-polycaprolactone (PCL) anhydrous polymer coating for enhanced sustained controlled-release functionality to provide catheters with effective antimicrobial properties. Varying the ratio of PEG and PEG-PCL copolymers resulted in polymers with different morphologies, consequently affecting the AMP release profiles. The optimal coating, formulated with 10% (w/w) PEG-PCL in PCL, achieved a controlled AMP release rate of 31.65 ± 6.85 μg/mL daily for up to 19 days, with a moderate initial burst release. Such profile is desired for antimicrobial coating as the initial burst release acts as a sterilizer to kill the bacteria present in the urinary tract upon insertion, and the subsequent linear release functions as a prophylaxis to deter opportunistic microbial infections. As a proof-of-concept application, our optimized coating was then applied to a commercial silicone catheter for further antibacterial tests. Preliminary results revealed that our coated catheters outperformed commercial silver-based antimicrobial catheters in terms of antimicrobial performance and sustainability, lasting for 4 days. Application of the controlled-release coating also aids in retarding biofilm formation, showing a lower extent of biofilm formation at the end of seven inoculation cycles.
Collapse
Affiliation(s)
- Esther Marie JieRong Lin
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, 2 Fusionopolis Way, 138634 Singapore
| | - Chee Leng Lay
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, 2 Fusionopolis Way, 138634 Singapore
| | - Gomathy Sandhya Subramanian
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, 2 Fusionopolis Way, 138634 Singapore
- Singapore Institute of Food and Biotechnology Innovation, Agency for Science, Technology and Research, 31 Biopolis Way, #01-02 Nanos, 138669 Singapore
| | - Wui Siew Tan
- Dornier Medtech Asia Pte Ltd., 2 Venture Drive, Vision Exchange, 608526 Singapore
| | | | - Lionel Chuan Hui Moh
- Institute of Materials Research and Engineering, Agency for Science, Technology and Research, 2 Fusionopolis Way, 138634 Singapore
| | - Kaiyang Lim
- ES-TA Technology Pte Ltd., 21 Jalan Mesin, 368819 Singapore
| |
Collapse
|
133
|
Hsu JC, Du Y, Sengupta A, Dong YC, Mossburg KJ, Bouché M, Maidment ADA, Weljie AM, Cormode DP. Effect of Nanoparticle Synthetic Conditions on Ligand Coating Integrity and Subsequent Nano-Biointeractions. ACS Appl Mater Interfaces 2021; 13:58401-58410. [PMID: 34846845 PMCID: PMC8715381 DOI: 10.1021/acsami.1c18941] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Most current nanoparticle formulations have relatively low clearance efficiency, which may hamper their likelihood for clinical translation. Herein, we sought to compare the clearance and cellular distribution profiles between sub-5 nm, renally-excretable silver sulfide nanoparticles (Ag2S-NPs) synthesized via either a bulk, high temperature, or a microfluidic, room temperature approach. We found that the thermolysis approach led to significant ligand degradation, but the surface coating shell was unaffected by the microfluidic synthesis. We demonstrated that the clearance was improved for Ag2S-NPs with intact ligands, with less uptake in the liver. Moreover, differential distribution in hepatic cells was observed, where Ag2S-NPs with degraded coatings tend to accumulate in Kupffer cells and those with intact coatings are more frequently found in hepatocytes. Therefore, understanding the impact of synthetic processes on ligand integrity and subsequent nano-biointeractions will aid in designing nanoparticle platforms with enhanced clearance and desired distribution profiles.
Collapse
Affiliation(s)
- Jessica C Hsu
- Department of Radiology, University of Pennsylvania, 3400 Spruce Street, 1 Silverstein, Philadelphia, Pennsylvania 19104, United States
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Yu Du
- Division of Gastroenterology and Hepatology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Arjun Sengupta
- Department of Systems Pharmacology and Translational Therapeutics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Yuxi C Dong
- Department of Radiology, University of Pennsylvania, 3400 Spruce Street, 1 Silverstein, Philadelphia, Pennsylvania 19104, United States
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Katherine J Mossburg
- Department of Radiology, University of Pennsylvania, 3400 Spruce Street, 1 Silverstein, Philadelphia, Pennsylvania 19104, United States
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Mathilde Bouché
- Department of Radiology, University of Pennsylvania, 3400 Spruce Street, 1 Silverstein, Philadelphia, Pennsylvania 19104, United States
| | - Andrew D A Maidment
- Department of Radiology, University of Pennsylvania, 3400 Spruce Street, 1 Silverstein, Philadelphia, Pennsylvania 19104, United States
| | - Aalim M Weljie
- Department of Systems Pharmacology and Translational Therapeutics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - David P Cormode
- Department of Radiology, University of Pennsylvania, 3400 Spruce Street, 1 Silverstein, Philadelphia, Pennsylvania 19104, United States
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| |
Collapse
|
134
|
Schmidt S, Haensch T, Frank R, Jahnke HG, Robitzki AA. Reactive Sputtered Silicon Nitride as an Alternative Passivation Layer for Microelectrode Arrays in Sensitive Bioimpedimetric Cell Monitoring. ACS Appl Mater Interfaces 2021; 13:59185-59195. [PMID: 34851082 DOI: 10.1021/acsami.1c14981] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Microelectrode arrays (MEAs) are widely used to study the behavior of cells noninvasively and in real time. While the design of MEAs focuses mainly on the electrode material or its application-dependent modification, the passivation layer, which is crucial to define the electrode area and to insulate the conducting paths, remains largely unnoticed. Because often most cells are in direct contact with the passivation layer rather than the electrode material, biocompatible photoresists such as SU-8 are almost exclusively used. However, SU-8 is not without limitations in terms of optical transmission, optimal cell support, or compatibility within polymer-based microfluidic lab on chip systems. Here, we established a silicon nitride (SiN) passivation by physical vapor deposition (PVD), which was optimized and evaluated for impedance spectroscopy-based monitoring of cells. Surface characteristics, biocompatibility, and electrical insulation capability were investigated and compared to SU8 in detail. To investigate the influence of the SiN passivation on the impedimetric analysis of cells, HEK-293 A and MCF-7 were chosen as adherent cell models and measured on microelectrodes of 50-200 μm in diameter. The results clearly revealed an overall suitability of SiN as alternative passivation. While for the smallest electrode size a cell line dependent comparable or slightly decreased cell signal could be observed in comparison with SU-8, a significant higher cell signal was observed for microelectrodes larger than 50 μm in diameter. Furthermore, a high suitability for the bonding of PEGDA and PDMS microfluidic structures on the SiN passivation layer without any leakage could be demonstrated.
Collapse
Affiliation(s)
- Sabine Schmidt
- Centre for Biotechnology and Biomedicine, Molecular Biological-Biochemical Processing Technology, Leipzig University, Deutscher Platz 5, D-04103 Leipzig, Germany
| | - Tobias Haensch
- Centre for Biotechnology and Biomedicine, Molecular Biological-Biochemical Processing Technology, Leipzig University, Deutscher Platz 5, D-04103 Leipzig, Germany
| | - Ronny Frank
- Centre for Biotechnology and Biomedicine, Molecular Biological-Biochemical Processing Technology, Leipzig University, Deutscher Platz 5, D-04103 Leipzig, Germany
| | - Heinz-Georg Jahnke
- Centre for Biotechnology and Biomedicine, Molecular Biological-Biochemical Processing Technology, Leipzig University, Deutscher Platz 5, D-04103 Leipzig, Germany
| | - Andrea A Robitzki
- Centre for Biotechnology and Biomedicine, Molecular Biological-Biochemical Processing Technology, Leipzig University, Deutscher Platz 5, D-04103 Leipzig, Germany
| |
Collapse
|
135
|
Gupta A, Sharma CP, Thamaraiselvan C, Pisharody L, Powell CD, Arnusch CJ. Low-Voltage Bacterial and Viral Killing Using Laser-Induced Graphene-Coated Non-woven Air Filters. ACS Appl Mater Interfaces 2021; 13:59373-59380. [PMID: 34851621 DOI: 10.1021/acsami.1c20198] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Laser-induced graphene (LIG) is uniquely positioned to advance applications in which electrically conductive carbon coatings are required. Recently, the antifouling, antiviral, and antibacterial properties of LIG have been proven in both air and water filtration applications. For example, an unsupported LIG based filter (pore size: ∼0.3 μm) demonstrated exceptional air filtration properties, while its joule heating effects successfully sterilized and removed unwanted biological components in air despite persisting challenges such as pressure drop, energy consumption, and lack of mechanical robustness. Here, we developed a polyimide (PI) non-woven supported LIG air filter with negligible pressure drop changes compared to the non-woven support material and showed that low electrical current density inactivates aerosolized bacteria. A current density of 4.5 mA/cm2 did not cause significant joule heating, and 97.2% bacterial removal was obtained. The low-voltage antibacterial mechanism was elucidated using bacterial inhibition experiments on a titanium surface and on an LIG surface fabricated on dense PI films. Complete sterilization was obtained using current densities of ∼8 mA/cm2 applied for 2 min or ∼ 6 mA/cm2 for 10 min upon the dense PI-LIG surface. Lastly, >98% bacterial removal was observed using a low-resistance LIG-coated non-woven polyimide air filter at 5 V. However, only very low voltages (∼0.3 V) were needed to remove ∼99% Pseudomonas aeruginosa bacteria and 100% of T4 virus when the LIG-coated filters were hybridized with a stainless steel mesh. Our results show that low current density levels at very low voltages are sufficient for substantial bacterial and viral inactivation, and that these principles might be effectively used in a wide number of air filtration applications such as air conditioners or other ventilation systems, which might limit the spread of infectious particles in hospitals, homes, workplaces, and the transportation industry.
Collapse
Affiliation(s)
- Abhishek Gupta
- Dept. of Desalination and Water Treatment, Zuckerberg Institute of Water Research, The Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, Midreshet Ben Gurion 8499000, Israel
| | - Chetan Prakash Sharma
- Dept. of Desalination and Water Treatment, Zuckerberg Institute of Water Research, The Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, Midreshet Ben Gurion 8499000, Israel
| | - Chidambaram Thamaraiselvan
- Dept. of Desalination and Water Treatment, Zuckerberg Institute of Water Research, The Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, Midreshet Ben Gurion 8499000, Israel
| | - Lakshmi Pisharody
- Dept. of Desalination and Water Treatment, Zuckerberg Institute of Water Research, The Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, Midreshet Ben Gurion 8499000, Israel
| | - Camilah D Powell
- Dept. of Desalination and Water Treatment, Zuckerberg Institute of Water Research, The Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, Midreshet Ben Gurion 8499000, Israel
| | - Christopher J Arnusch
- Dept. of Desalination and Water Treatment, Zuckerberg Institute of Water Research, The Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, Midreshet Ben Gurion 8499000, Israel
| |
Collapse
|
136
|
Ji YR, Cheng CC, Lee AL, Shieh JCC, Wu HJ, Huang APH, Hsu YH, Young TH. Poly(allylguanidine)-Coated Surfaces Regulate TGF-β in Glioblastoma Cells to Induce Apoptosis via NF-κB Pathway Activation. ACS Appl Mater Interfaces 2021; 13:59400-59410. [PMID: 34846137 DOI: 10.1021/acsami.1c21027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Polycationic biomaterials are currently widely applied in neuronal cell cultures to promote cell adhesion and viability. However, polycations generally have cytotoxic properties that limit their application in the field of biomaterials. In this study, we examined the use of a novel polycation poly(allylguanidine) (PAG), which contains a guanidine group in the side chain and a structure similar to poly(allylamine hydrochloride) (PAH), an example of another commonly used polycation. Our findings showed that exposure to PAG induced apoptosis in glioblastoma (GBM) cells, while exposure to PAH induced necrosis. Compared to control groups, the PAG coating significantly limited the proliferation of GBM8901 in vitro and in vivo. Furthermore, GBM8901 cells exposed to the PAG coating exhibited increased levels of phospho-p65 and phosphor-IκB, implying that GBM8901 cells underwent apoptotic cell death via the NF-κB pathway by the regulation of TGF-β. This result was further confirmed to be consistent with the experimental results from western blot protein analysis and apoptosis/necrosis assays. These findings indicate that the polycation PAG has the potential to not only suppress the proliferation of GBM8901 cancer cells but also improve the neural viability and promote the differentiation of neural stem/precursor cells into mature neurons. In conclusion, biomaterials such as PAG act as extremely potent options for applications in the treatment of pathological conditions such as brain cancer.
Collapse
Affiliation(s)
- You-Ren Ji
- Department of Biomedical Engineering, National Taiwan University, Taipei 100, Taiwan
| | - Ching-Chia Cheng
- Department of Biomedical Engineering, National Taiwan University, Taipei 100, Taiwan
| | - An-Li Lee
- Department of Biomedical Engineering, National Taiwan University, Taipei 100, Taiwan
- Division of Plastic Surgery, Department of Surgery, MacKay Memorial Hospital, Taipei 104, Taiwan
- Department of Medicine, MacKay Medical College, New Taipei City 252, Taiwan
| | | | - Hsin-Ju Wu
- Department of Biomedical Engineering, National Taiwan University, Taipei 100, Taiwan
| | - Abel Po-Hao Huang
- Department of Surgery, National Taiwan University Hospital and College of Medicine, Taipei 100, Taiwan
| | - Yi-Hua Hsu
- Department of Surgery, National Taiwan University Hospital and College of Medicine, Taipei 100, Taiwan
| | - Tai-Horng Young
- Department of Biomedical Engineering, National Taiwan University, Taipei 100, Taiwan
- Department of Biomedical Engineering, National Taiwan University Hospital, Taipei 100, Taiwan
| |
Collapse
|
137
|
Marinaro F, Silva JM, Barros AA, Aroso IM, Gómez-Blanco JC, Jardin I, Lopez JJ, Pulido M, de Pedro MÁ, Reis RL, Sánchez-Margallo FM, Casado JG, López E. A Fibrin Coating Method of Polypropylene Meshes Enables the Adhesion of Menstrual Blood-Derived Mesenchymal Stromal Cells: A New Delivery Strategy for Stem Cell-Based Therapies. Int J Mol Sci 2021; 22:13385. [PMID: 34948187 PMCID: PMC8706515 DOI: 10.3390/ijms222413385] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 12/07/2021] [Accepted: 12/08/2021] [Indexed: 12/11/2022] Open
Abstract
Polypropylene (PP) mesh is well-known as a gold standard of all prosthetic materials of choice for the reinforcement of soft tissues in case of hernia, organ prolapse, and urinary incontinence. The adverse effects that follow surgical mesh implantation remain an unmet medical challenge. Herein, it is outlined a new approach to allow viability and adhesion of human menstrual blood-derived mesenchymal stromal cells (MenSCs) on PP surgical meshes. A multilayered fibrin coating, based on fibrinogen and thrombin from a commercial fibrin sealant, was optimized to guarantee a homogeneous and stratified film on PP mesh. MenSCs were seeded on the optimized fibrin-coated meshes and their adhesion, viability, phenotype, gene expression, and immunomodulatory capacity were fully evaluated. This coating guaranteed MenSC viability, adhesion and did not trigger any change in their stemness and inflammatory profile. Additionally, MenSCs seeded on fibrin-coated meshes significantly decreased CD4+ and CD8+ T cell proliferation, compared to in vitro stimulated lymphocytes (p < 0.0001). Hence, the proposed fibrin coating for PP surgical meshes may allow the local administration of stromal cells and the reduction of the exacerbated inflammatory response following mesh implantation surgery. Reproducible and easy to adapt to other cell types, this method undoubtedly requires a multidisciplinary and translational approach to be improved for future clinical uses.
Collapse
Affiliation(s)
- Federica Marinaro
- Stem Cell Therapy Unit, Jesús Usón Minimally Invasive Surgery Centre, 10071 Cáceres, Spain; (J.C.G.-B.); (M.P.); (M.Á.d.P.); (E.L.)
| | - Joana M. Silva
- 3B’s Research Group, I3Bs-Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, Avepark, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal; (J.M.S.); (A.A.B.); (I.M.A.); (R.L.R.)
- ICVS/3B’s-PT Government Associate Laboratory, 4805-017 Guimarães, Portugal
| | - Alexandre A. Barros
- 3B’s Research Group, I3Bs-Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, Avepark, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal; (J.M.S.); (A.A.B.); (I.M.A.); (R.L.R.)
- ICVS/3B’s-PT Government Associate Laboratory, 4805-017 Guimarães, Portugal
| | - Ivo M. Aroso
- 3B’s Research Group, I3Bs-Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, Avepark, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal; (J.M.S.); (A.A.B.); (I.M.A.); (R.L.R.)
- ICVS/3B’s-PT Government Associate Laboratory, 4805-017 Guimarães, Portugal
| | - Juan C. Gómez-Blanco
- Stem Cell Therapy Unit, Jesús Usón Minimally Invasive Surgery Centre, 10071 Cáceres, Spain; (J.C.G.-B.); (M.P.); (M.Á.d.P.); (E.L.)
| | - Isaac Jardin
- Cell Physiology Research Group, Department of Physiology, University of Extremadura, 10003 Cáceres, Spain; (I.J.); (J.J.L.)
- Institute of Molecular Pathology Biomarkers, University of Extremadura, 10003 Cáceres, Spain;
| | - Jose J. Lopez
- Cell Physiology Research Group, Department of Physiology, University of Extremadura, 10003 Cáceres, Spain; (I.J.); (J.J.L.)
- Institute of Molecular Pathology Biomarkers, University of Extremadura, 10003 Cáceres, Spain;
| | - María Pulido
- Stem Cell Therapy Unit, Jesús Usón Minimally Invasive Surgery Centre, 10071 Cáceres, Spain; (J.C.G.-B.); (M.P.); (M.Á.d.P.); (E.L.)
| | - María Ángeles de Pedro
- Stem Cell Therapy Unit, Jesús Usón Minimally Invasive Surgery Centre, 10071 Cáceres, Spain; (J.C.G.-B.); (M.P.); (M.Á.d.P.); (E.L.)
| | - Rui L. Reis
- 3B’s Research Group, I3Bs-Research Institute on Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, Avepark, Zona Industrial da Gandra, 4805-017 Barco, Guimarães, Portugal; (J.M.S.); (A.A.B.); (I.M.A.); (R.L.R.)
- ICVS/3B’s-PT Government Associate Laboratory, 4805-017 Guimarães, Portugal
| | - Francisco Miguel Sánchez-Margallo
- Stem Cell Therapy Unit, Jesús Usón Minimally Invasive Surgery Centre, 10071 Cáceres, Spain; (J.C.G.-B.); (M.P.); (M.Á.d.P.); (E.L.)
- Centro de Investigación en Red en Enfermedades Cardiovasculares (CIBERCV), 28029 Madrid, Spain
| | - Javier G. Casado
- Institute of Molecular Pathology Biomarkers, University of Extremadura, 10003 Cáceres, Spain;
- Centro de Investigación en Red en Enfermedades Cardiovasculares (CIBERCV), 28029 Madrid, Spain
- Immunology Unit, Department of Physiology, University of Extremadura, 10003 Cáceres, Spain
| | - Esther López
- Stem Cell Therapy Unit, Jesús Usón Minimally Invasive Surgery Centre, 10071 Cáceres, Spain; (J.C.G.-B.); (M.P.); (M.Á.d.P.); (E.L.)
| |
Collapse
|
138
|
Li L, Chen C, Zhang C, Luo R, Lan X, Guo F, Ma L, Fu P, Wang Y. A honokiol-mediated robust coating for blood-contacting devices with anti-inflammatory, antibacterial and antithrombotic properties. J Mater Chem B 2021; 9:9770-9783. [PMID: 34806726 DOI: 10.1039/d1tb01617b] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Thrombus, bacterial infections, and severe inflammation are still serious problems that have to be faced with blood-contacting materials. However, it is a great challenge to simultaneously meet the above functional requirements in a simple, economical and efficient method. As such, we put forward a robust and versatile coating strategy by covalently modifying the multi-pharmacological drug honokiol (HK) with an amine-rich polydopamine/polyethyleneimine coating, through which anticoagulant, antibacterial and anti-inflammatory properties were obtained (DPHc) simultaneously. The amine content in the DPHc coating was lower than the detection limit, while it contained abundant phenolic hydroxyl groups (49 μmol cm-2). Meanwhile, the 30 day drug release test confirmed that the drug was firmly modified on the surface of the coating without release. A systematic in vitro and ex vivo evaluation confirmed that the coating had significant anti-thrombotic properties. The antibacterial rates of the DPHc coating against Staphylococcus aureus and Escherichia coli reached 99.98% and 99.99%, respectively. In addition, subcutaneous implantation indicated that the DPHc coating also has excellent histocompatibility. To the best of our knowledge, this is the first study using HK as a coating material that can not only combat thrombosis and infection but also significantly inhibit inflammation associated with the use of blood-contacting materials, thus expanding the application of HK in the field of biomaterials.
Collapse
Affiliation(s)
- Linhua Li
- Kidney Research Institute, National Clinical Research Center for Geriatrics and Division of Nephrology, West China Hospital of Sichuan University, Chengdu 610041, China.
| | - Chong Chen
- Laboratory of Biomechanical Engineering, Department of Applied Mechanics, College of Architecture & Environment, Sichuan University, Chengdu, 610064, China
| | - Chunle Zhang
- Kidney Research Institute, National Clinical Research Center for Geriatrics and Division of Nephrology, West China Hospital of Sichuan University, Chengdu 610041, China.
| | - Rifang Luo
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China.
| | - Xiaorong Lan
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China.
| | - Fan Guo
- Kidney Research Institute, National Clinical Research Center for Geriatrics and Division of Nephrology, West China Hospital of Sichuan University, Chengdu 610041, China.
| | - Liang Ma
- Kidney Research Institute, National Clinical Research Center for Geriatrics and Division of Nephrology, West China Hospital of Sichuan University, Chengdu 610041, China.
| | - Ping Fu
- Kidney Research Institute, National Clinical Research Center for Geriatrics and Division of Nephrology, West China Hospital of Sichuan University, Chengdu 610041, China.
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610064, China.
| |
Collapse
|
139
|
Ni X, Li C, Lei Y, Shao Y, Zhu Y, You B. Design of a Smart Self-Healing Coating with Multiple-Responsive Superhydrophobicity and Its Application in Antibiofouling and Antibacterial Abilities. ACS Appl Mater Interfaces 2021; 13:57864-57879. [PMID: 34807561 DOI: 10.1021/acsami.1c15239] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Inspired by the restoration of the superhydrophobic surfaces after the damage in nature such as lotus leaf and clover, smart self-healing coating with controllable release of loaded healing agents is both of scientific and technological interest. Herein, a smart self-healing coating with superhydrophobicity was gained through blending UV/NIR/acid/base multiple-responsive ZnO-encapsulated mesoporous polydopamine (MPDA) microspheres (zinc oxide-encapsulated mesoporous polydopamine microspheres) with silicone latex and hydrophobic nanoparticles. The hydrophobic and micro/nanostructured ZnO-encapsulated MPDA microspheres provided UV/NIR/acid/base multiple response sources for the smart self-healing coating, combining the photocatalytic activity and acid/base solubility of ZnO nanoparticles, zwitterionic characteristic of amino-modified silicone oil (ASO), as well as the photothermal conversion abilities and charge characteristics of PDA. The ZnO nanoparticles simultaneously acted as the protective layer for the stimuli-responsive microspheres and functional filler in the coating, contributing to realize the controllable and long-period release of loaded hydrophobic ASO and the further antibacterial functionalization for the coating. The super/high hydrophobicity and antibiofouling performances of the coating could be self-healed by UV, NIR, acid, or base stimuli, attributing to the release of ASO from the microspheres. Then, large-area, rapid, and controllable healing superiority could be achieved on the coating with the combined multiple responses under different conditions. Robust environmental endurances for superhydrophobic coating were also confirmed under harsh environments by directly exposing to UV-accelerated weathering and immersing into various solutions (including strong acid/base, salt, and artificial seawater solution). This smart coating has high application prospects due to its environmentally friendly nature, excellent self-healing, and multifunctional characteristics, and the multiple-responsive ZnO-encapsulated MPDA microspheres can be used for the functionalization of other materials.
Collapse
Affiliation(s)
- Xingxing Ni
- Department of Materials Science and Advanced Coatings Research Center of Ministry of Education, Fudan University, Shanghai 200433, P. R. China
| | - Chenxi Li
- Department of Materials Science and Advanced Coatings Research Center of Ministry of Education, Fudan University, Shanghai 200433, P. R. China
| | - Yang Lei
- Department of Materials Science and Advanced Coatings Research Center of Ministry of Education, Fudan University, Shanghai 200433, P. R. China
| | - Yiran Shao
- Key Laboratory of Inorganic Coating Materials CAS, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, P. R. China
| | - Yingchun Zhu
- Key Laboratory of Inorganic Coating Materials CAS, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, P. R. China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Bo You
- Department of Materials Science and Advanced Coatings Research Center of Ministry of Education, Fudan University, Shanghai 200433, P. R. China
| |
Collapse
|
140
|
Kafle P, Sanghavi R, Khasbaatar A, Punjani S, Davies DW, Diao Y. Drastic Modulation of Molecular Packing and Intrinsic Dissolution Rates by Meniscus-Guided Coating of Extremely Confined Pharmaceutical Thin Films. ACS Appl Mater Interfaces 2021; 13:56519-56529. [PMID: 34783517 DOI: 10.1021/acsami.1c08398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Nanosizing has emerged as one of the most effective formulation strategies for enhancement of dissolution properties of active pharmaceutical ingredients (APIs). In addition to enhancing the specific area of the dissolving solids, nanosizing can also capture and stabilize the metastable form of the API, which can further enhance the solubility by drastic modulation of surface energies. Herein, we employ meniscus-guided coating to fabricate nanothin films of three APIs that show anticancer properties and are poorly soluble:10-HCPT, SN-38, and amonafide. By modulating the coating speed, we systematically deposited the APIs in films ranging from ∼200 nm thickness to extreme confinement of ∼10 nm (<10 molecular layers). In all three APIs, we observe a general order-to-disorder transition with semicrystalline (10-HCPT and amonafide) or amorphous (SN-38) form of API solids trapped in thin films when the thickness decreases below a critical value of ∼25-30 nm. The existence of a critical thickness highlights the importance of nanoconfinement in tuning molecular packing. In the case of 10-HCPT, we demonstrate that the disordered form of the API occurs largely due to lack of incorporation of water molecules in thinner films below the critical thickness, thereby disrupting the three-dimensional hydrogen-bonded network held by water molecules. We further developed a dissolution model that predicts variation of the intrinsic dissolution rate (IDR) with API film thickness, which also closely matched with experimental results. We achieved drastic improvement in the IDR of ∼240% in 10-HCPT by decreasing film thickness alone. Further leveraging the order-to-disorder transition led to 2570% modulation of the IDR for amonafide. Our work demonstrates, for the first time, opportunities to largely modulate API dissolution by precisely controlling the dimensionality of thin films.
Collapse
Affiliation(s)
- Prapti Kafle
- Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, Illinois 61801, United States
| | - Rishabh Sanghavi
- Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, Illinois 61801, United States
| | - Azzaya Khasbaatar
- Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, Illinois 61801, United States
| | - Samdisha Punjani
- Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, Illinois 61801, United States
| | - Daniel W Davies
- Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, Illinois 61801, United States
| | - Ying Diao
- Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, 600 South Mathews Avenue, Urbana, Illinois 61801, United States
- Beckman Institute, Molecular Science and Engineering, University of Illinois at Urbana-Champaign, 405 N Mathews Avenue, Urbana, Illinois 61801, United States
- Materials Research Laboratory, University of Illinois at Urbana-Champaign, 104 South Goodwin Avenue MC-230, Urbana, Illinois 61801, United States
| |
Collapse
|
141
|
Ye R, Zheng Y, Chen Y, Wei X, Shi S, Chen Y, Zhu W, Wang A, Yang L, Xu Y, Peng J. Stable Loading and Delivery of Melittin with Lipid-Coated Polymeric Nanoparticles for Effective Tumor Therapy with Negligible Systemic Toxicity. ACS Appl Mater Interfaces 2021; 13:55902-55912. [PMID: 34793125 DOI: 10.1021/acsami.1c17618] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Melittin is a potential anticancer candidate with remarkable antitumor activity and ability to overcome tumor drug resistance. However, the clinical applications of melittin are largely restricted by its severe hemolytic activity and nonspecific cytotoxicity after systemic administration. Here, a biocompatible and stable melittin-loaded lipid-coated polymeric nanoparticle (MpG@LPN) formulation that contains a melittin/poly-γ-glutamic acid nanoparticle inner core, a lipid membrane middle layer, and a polyethylene glycol (PEG) and PEG-targeting molecule outer shell was designed. The formulations were prepared by applying a self-assembly procedure based on intermolecular interactions, including electrostatic attraction and hydrophobic effect. The core-shell MpG@LPN presented high efficiency for melittin encapsulation and high stability in physiological conditions. Hemolysis and cell proliferation assays showed that the PEG-modified MpG@LPN had almost no hemolytic activity and nonspecific cytotoxicity even at high concentrations. The modification of targeting molecules on the MpG@LPNs allowed for the selective binding with target tumor cells and cytolytic activity via apoptosis induction. In vivo experiments revealed that MpG@LPNs can remarkably inhibit the growth of tumors without the occurrence of hemolysis and tissue toxicity. Results suggested that the developed MpG@LPN with a core-shell structure can effectively address the main obstacles of melittin in clinical applications and has great potential in cancer treatment.
Collapse
Affiliation(s)
- Ran Ye
- School of Pharmacy, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Yuan Zheng
- School of Pharmacy, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Yang Chen
- School of Pharmacy, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Xiaohui Wei
- School of Pharmacy, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Sanyuan Shi
- School of Pharmacy, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Yuetan Chen
- School of Pharmacy, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Wanxin Zhu
- School of Pharmacy, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Anqi Wang
- School of Pharmacy, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Liuxin Yang
- School of Pharmacy, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Yuhong Xu
- School of Pharmacy, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
- School of Pharmacy and Chemistry, Dali University, Dali City 671000, P. R. China
| | - Jinliang Peng
- School of Pharmacy, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| |
Collapse
|
142
|
Zhang N, Lin J, Chew SY. Neural Cell Membrane-Coated Nanoparticles for Targeted and Enhanced Uptake by Central Nervous System Cells. ACS Appl Mater Interfaces 2021; 13:55840-55850. [PMID: 34792341 DOI: 10.1021/acsami.1c16543] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Targeted drug delivery to specific neural cells within the central nervous system (CNS) plays important roles in treating neurological disorders, such as neurodegenerative (e.g., targeting neurons) and demyelinating diseases [e.g., targeting oligodendrocytes (OLs)]. However, the presence of many other cell types within the CNS, such as microglial and astrocytes, may lead to nonspecific uptake and subsequent side effects. As such, exploring an effective and targeted drug delivery system is of great necessity. Synthetic micro-/nanoparticles that have been coated with biologically derived cellular membranes have emerged as a new class of drug delivery vehicles. However, the use of neural cell-derived membrane coatings remains unexplored. Here, we utilized this technique and demonstrated the efficacy of targeted delivery by using four types of cell membranes that were derived from the CNS, namely, microglial, astrocytes, oligodendrocyte progenitor cells (OPCs), and cortical neurons. A successful cell membrane coating over poly(ε-caprolactone) nanoparticles (NPs) was confirmed using dynamic light scattering, zeta potential measurements, and transmission electron microscopy. Subsequently, an extensive screening of these cell membrane-coated NPs was carried out on various CNS cells. Results suggested that microglial and OLs were the most sensitive cell types toward cell membrane-coated NPs. Specifically, cell membrane-coated NPs significantly enhanced the uptake efficiency of OLs (p < 0.001). Additionally, a temporal uptake study indicated that the OLs took up microglial membrane-coated NPs (DPP-PCL-M Mem) most efficiently. Besides that, coating the NPs with four types of the CNS cell membrane did not result in obvious specific uptake in microglial but reduced the activation of microglial, especially for DPP-PCL-M Mem (p < 0.01). Taken together, DPP-PCL-M Mem were uptaken most efficiently in OLs and did not induce significant microglial activation and may be most suitable for CNS drug delivery applications.
Collapse
Affiliation(s)
- Na Zhang
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore 637459, Singapore
| | - Junquan Lin
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore 637459, Singapore
| | - Sing Yian Chew
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore 637459, Singapore
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore 308232, Singapore
| |
Collapse
|
143
|
Guo Y, Fan Y, Li G, Wang Z, Shi X, Shen M. "Cluster Bomb" Based on Redox-Responsive Carbon Dot Nanoclusters Coated with Cell Membranes for Enhanced Tumor Theranostics. ACS Appl Mater Interfaces 2021; 13:55815-55826. [PMID: 34783516 DOI: 10.1021/acsami.1c15282] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Designing intelligent stimuli-responsive nanoplatforms that are integrated with a biological membrane system and nanomaterials to realize efficient imaging and therapy of tumors still remains to be challenging. Herein, we report a unique strategy to prepare redox-responsive yellow fluorescent carbon dot nanoclusters (y-CDCs) loaded with anticancer drug doxorubicin (DOX) and coated with the cancer cell membrane (CCM) for precision fluorescence imaging and homologous targeting chemotherapy of tumors. The y-CDs with a size of 7.2 nm were first synthesized via a hydrothermal method and crosslinked to obtain redox-responsive y-CDCs with a size of 150.0 nm. The formulated y-CDCs were physically loaded with DOX with an efficiency of up to 81.0% and coated with CCM to endow them with antifouling properties, immune escape ability to escape from macrophage uptake, and homologous targeting capability to cancer cells. Within the reductive tumor microenvironment, the y-CDCs with quenched fluorescence can dissociate to form single y-CDs with recovered fluorescence and improved tumor penetration ability and simultaneously release DOX from the "cluster bomb", thus realizing efficient targeted tumor fluorescence imaging and chemotherapy. The designed y-CDCs/DOX@CCM may represent an updated nanomedicine formulation based on CDs for improved theranostics of different types of tumors.
Collapse
Affiliation(s)
- Yunqi Guo
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, P. R. China
| | - Yu Fan
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, P. R. China
| | - Gaoming Li
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, P. R. China
| | - Zhiqiang Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, P. R. China
| | - Xiangyang Shi
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, P. R. China
| | - Mingwu Shen
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, P. R. China
| |
Collapse
|
144
|
Liu F, Xia L, Zhang L, Guo F, Zhang X, Yu Y, Yang R. Sunflower-Stalk-Based Solar-Driven Evaporator with a Confined 2D Water Channel and an Enclosed Thermal-Insulating Cellular Structure for Stable and Efficient Steam Generation. ACS Appl Mater Interfaces 2021; 13:55299-55306. [PMID: 34780144 DOI: 10.1021/acsami.1c20747] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Given the worsening freshwater scarcity around the world, the interfacial solar-driven steam generation for seawater desalination and wastewater treatment has attracted wide attention due to its rich energy resources, convenience, and environmental friendliness. However, challenges still remain for developing high-efficiency interfacial solar-driven steam generation devices from low-cost, readily available, and green material resources. Herein, taking advantage of the delicate composite structure of the sunflower stalk, a sunflower-stalk-based solar-driven evaporator with a confined two-dimensional (2D) water supply pathway and an enclosed thermal-insulating structure is reported. The pith of sunflower stalks is composed of well-arranged honeycomb-like parenchyma cells that endow sunflower stalks with low thermal conductivity comparable to that of synthetic plastic foam. The low-tortuosity vascular bundles in the skin can serve as a natural 2D water pathway for rapid water transportation. The benefit of these functions is that an evaporator based on a carbon-nanotube-coated sunflower stalk (C-Ss) achieves a high evaporation rate of 1.76 kg m-2 h-1 under 1 sun irradiation (1 kW m-2). The C-Ss also shows a highly stable evaporation performance, high ion rejection efficiency, and a self-cleaning ability during the actual seawater desalination process. With advantages of abundant resources, easy fabrication, and sustainability, this C-Ss-based evaporator provides a promising choice for freshwater production in developing regions.
Collapse
Affiliation(s)
- Fangqingxin Liu
- College of Material Engineering, Fujian Agriculture and Forestry University, Fuzhou 350108, China
- National Forestry and Grassland Administration Key Laboratory of Plant Fiber Functional Materials, Fuzhou 350002, China
| | - Linmin Xia
- College of Material Engineering, Fujian Agriculture and Forestry University, Fuzhou 350108, China
- National Forestry and Grassland Administration Key Laboratory of Plant Fiber Functional Materials, Fuzhou 350002, China
| | - Lingyan Zhang
- College of Material Engineering, Fujian Agriculture and Forestry University, Fuzhou 350108, China
- National Forestry and Grassland Administration Key Laboratory of Plant Fiber Functional Materials, Fuzhou 350002, China
| | - Fei Guo
- College of Material Engineering, Fujian Agriculture and Forestry University, Fuzhou 350108, China
- National Forestry and Grassland Administration Key Laboratory of Plant Fiber Functional Materials, Fuzhou 350002, China
| | - Xuexia Zhang
- College of Material Engineering, Fujian Agriculture and Forestry University, Fuzhou 350108, China
- National Forestry and Grassland Administration Key Laboratory of Plant Fiber Functional Materials, Fuzhou 350002, China
| | - Yan Yu
- College of Material Engineering, Fujian Agriculture and Forestry University, Fuzhou 350108, China
- National Forestry and Grassland Administration Key Laboratory of Plant Fiber Functional Materials, Fuzhou 350002, China
| | - Rilong Yang
- College of Material Engineering, Fujian Agriculture and Forestry University, Fuzhou 350108, China
- National Forestry and Grassland Administration Key Laboratory of Plant Fiber Functional Materials, Fuzhou 350002, China
| |
Collapse
|
145
|
Sun Q, Hou X, Yang J, Zhang M, Yang Y, Liu Y, Shen W, Yin D. Heparin-Coated Photosensitive Metal-Organic Frameworks as Drug Delivery Nanoplatforms of Autophagy Inhibitors for Sensitized Photodynamic Therapy against Breast Cancer. ACS Appl Mater Interfaces 2021; 13:55577-55590. [PMID: 34762394 DOI: 10.1021/acsami.1c18055] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Photosensitive nanosized metal-organic frameworks (nanoMOFs) with a tunable structure and high porosity have been developed recently as nanophotosensitizers (nanoPSs) for photodynamic therapy (PDT). However, the effect of photodynamic therapy is greatly limited by the fast blood clearance and poor tumor retention of the ordinary nanoPSs. Besides, autophagy, a prosurvival self-cannibalization pathway mediated by autolysosomes, was elevated by cytotoxic reactive oxygen species (ROS) produced during PDT. Herein, a chloroquine phosphate (CQ)-loaded photosensitive nanoMOF coated by heparin was fabricated for sensitized PDT by increasing the tumor accumulation of nanoPSs and abolishing the self-protective autophagy within cancer cells. After internalization by cancer cells, the encapsulated CQ alkalizes autolysosomes and blocks the postautophagy process, which disarm the vigilant cancer cells irritated by PDT and finally enhance the therapeutic effect. Furthermore, the accompanied antiangiogenesis ability of the heparin coat also helps improve the cancer therapy outcomes. This study would open up new horizons for building heparin-coated nanoMOFs and understanding the role of autophagy in cancer therapy.
Collapse
Affiliation(s)
- Quanwei Sun
- School of Pharmacy, Anhui University of Chinese Medicine, Hefei 230031, China
| | - Xiaohui Hou
- School of Pharmacy, Anhui University of Chinese Medicine, Hefei 230031, China
| | - Jinming Yang
- School of Pharmacy, Anhui University of Chinese Medicine, Hefei 230031, China
| | - Mengmeng Zhang
- School of Pharmacy, Anhui University of Chinese Medicine, Hefei 230031, China
| | - Ye Yang
- School of Pharmacy, Anhui University of Chinese Medicine, Hefei 230031, China
- Anhui Province Key Laboratory of Pharmaceutical Preparation Technology and Application, Hefei 230031, China
- Key Laboratory of Xin'an Medicine, Ministry of Education, Hefei 230038, China
| | - Yang Liu
- School of Pharmacy, Anhui University of Chinese Medicine, Hefei 230031, China
| | - Wei Shen
- School of Pharmacy, Anhui University of Chinese Medicine, Hefei 230031, China
- Anhui Provincial Key Laboratory of Research & Development of Chinese Medicine, Hefei 230021, China
| | - Dengke Yin
- School of Pharmacy, Anhui University of Chinese Medicine, Hefei 230031, China
- Anhui Provincial Key Laboratory of Research & Development of Chinese Medicine, Hefei 230021, China
- Key Laboratory of Xin'an Medicine, Ministry of Education, Hefei 230038, China
| |
Collapse
|
146
|
Billing F, Walter B, Fink S, Arefaine E, Pickarski L, Maier S, Kretz R, Jakobi M, Feuerer N, Schneiderhan-Marra N, Burkhardt C, Templin M, Zeck A, Krastev R, Hartmann H, Shipp C. Altered Proinflammatory Responses to Polyelectrolyte Multilayer Coatings Are Associated with Differences in Protein Adsorption and Wettability. ACS Appl Mater Interfaces 2021; 13:55534-55549. [PMID: 34762399 DOI: 10.1021/acsami.1c16175] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
A full understanding of the relationship between surface properties, protein adsorption, and immune responses is lacking but is of great interest for the design of biomaterials with desired biological profiles. In this study, polyelectrolyte multilayer (PEM) coatings with gradient changes in surface wettability were developed to shed light on how this impacts protein adsorption and immune response in the context of material biocompatibility. The analysis of immune responses by peripheral blood mononuclear cells to PEM coatings revealed an increased expression of proinflammatory cytokines tumor necrosis factor (TNF)-α, macrophage inflammatory protein (MIP)-1β, monocyte chemoattractant protein (MCP)-1, and interleukin (IL)-6 and the surface marker CD86 in response to the most hydrophobic coating, whereas the most hydrophilic coating resulted in a comparatively mild immune response. These findings were subsequently confirmed in a cohort of 24 donors. Cytokines were produced predominantly by monocytes with a peak after 24 h. Experiments conducted in the absence of serum indicated a contributing role of the adsorbed protein layer in the observed immune response. Mass spectrometry analysis revealed distinct protein adsorption patterns, with more inflammation-related proteins (e.g., apolipoprotein A-II) present on the most hydrophobic PEM surface, while the most abundant protein on the hydrophilic PEM (apolipoprotein A-I) was related to anti-inflammatory roles. The pathway analysis revealed alterations in the mitogen-activated protein kinase (MAPK)-signaling pathway between the most hydrophilic and the most hydrophobic coating. The results show that the acute proinflammatory response to the more hydrophobic PEM surface is associated with the adsorption of inflammation-related proteins. Thus, this study provides insights into the interplay between material wettability, protein adsorption, and inflammatory response and may act as a basis for the rational design of biomaterials.
Collapse
Affiliation(s)
- Florian Billing
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Bernadette Walter
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Simon Fink
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Elsa Arefaine
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Luisa Pickarski
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Sandra Maier
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Robin Kretz
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Meike Jakobi
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Nora Feuerer
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
- Department of Biomedical Engineering, Eberhard Karls University Tübingen, 72076 Tübingen, Germany
| | | | - Claus Burkhardt
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Markus Templin
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Anne Zeck
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Rumen Krastev
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
- Faculty of Applied Chemistry, Reutlingen University, 72762 Reutlingen, Germany
| | - Hanna Hartmann
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| | - Christopher Shipp
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| |
Collapse
|
147
|
Jung O, Hesse B, Stojanovic S, Seim C, Weitkamp T, Batinic M, Goerke O, Kačarević ŽP, Rider P, Najman S, Barbeck M. Biocompatibility Analyses of HF-Passivated Magnesium Screws for Guided Bone Regeneration (GBR). Int J Mol Sci 2021; 22:ijms222212567. [PMID: 34830451 PMCID: PMC8624161 DOI: 10.3390/ijms222212567] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 11/19/2021] [Accepted: 11/19/2021] [Indexed: 11/17/2022] Open
Abstract
Background: Magnesium (Mg) is one of the most promising materials for human use in surgery due to material characteristics such as its elastic modulus as well as its resorbable and regenerative properties. In this study, HF-coated and uncoated novel bioresorbable magnesium fixation screws for maxillofacial and dental surgical applications were investigated in vitro and in vivo to evaluate the biocompatibility of the HF coating. Methods: Mg alloy screws that had either undergone a surface treatment with hydrofluoric-acid (HF) or left untreated were investigated. In vitro investigation included XTT, BrdU and LDH in accordance with the DIN ISO 10993-5/-12. In vivo, the screws were implanted into the tibia of rabbits. After 3 and 6 weeks, degradation, local tissue reactions and bony integration were analyzed histopathologically and histomorphometrically. Additionally, SEM/EDX analysis and synchrotron phase-contrast microtomography (µCT) measurements were conducted. The in vitro analyses revealed that the Mg screws are cytocompatible, with improved results when the surface had been passivated with HF. In vivo, the HF-treated Mg screws implanted showed a reduction in gas formation, slower biodegradation and a better bony integration in comparison to the untreated Mg screws. Histopathologically, the HF-passivated screws induced a layer of macrophages as part of its biodegradation process, whereas the untreated screws caused a slight fibrous tissue reaction. SEM/EDX analysis showed that both screws formed a similar layer of calcium phosphates on their surfaces and were surrounded by bone. Furthermore, the µCT revealed the presence of a metallic core of the screws, a faster absorbing corrosion front and a slow absorbing region of corroded magnesium. Conclusions: Overall, the HF-passivated Mg fixation screws showed significantly better biocompatibility in vitro and in vivo compared to the untreated screws.
Collapse
Affiliation(s)
- Ole Jung
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, 18057 Rostock, Germany;
| | | | - Sanja Stojanovic
- Department of Biology and Human Genetics, Faculty of Medicine, University of Niš, 18108 Niš, Serbia; (S.S.); (S.N.)
- Scientific Research Center for Biomedicine, Faculty of Medicine, Department for Cell and Tissue Engineering, University of Niš, 18108 Niš, Serbia
| | | | - Timm Weitkamp
- Synchrotron SOLEIL, Gif-sur-Yvette, 91190 Saint-Aubin, France;
| | - Milijana Batinic
- Department of Ceramic Materials, Chair of Advanced Ceramic Materials, Institute for Materials Science and Technologies, Technical University of Berlin, 10623 Berlin, Germany; (M.B.); (O.G.)
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
| | - Oliver Goerke
- Department of Ceramic Materials, Chair of Advanced Ceramic Materials, Institute for Materials Science and Technologies, Technical University of Berlin, 10623 Berlin, Germany; (M.B.); (O.G.)
| | - Željka Perić Kačarević
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
| | - Patrick Rider
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
| | - Stevo Najman
- Department of Biology and Human Genetics, Faculty of Medicine, University of Niš, 18108 Niš, Serbia; (S.S.); (S.N.)
- Scientific Research Center for Biomedicine, Faculty of Medicine, Department for Cell and Tissue Engineering, University of Niš, 18108 Niš, Serbia
| | - Mike Barbeck
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
- Correspondence: ; Tel.: +49-176-810-224-6
| |
Collapse
|
148
|
Li S, Wang B, Jiang S, Pan Y, Shi Y, Kong W, Shan Y. Surface-Functionalized Silica-Coated Calcium Phosphate Nanoparticles Efficiently Deliver DNA-Based HIV-1 Trimeric Envelope Vaccines against HIV-1. ACS Appl Mater Interfaces 2021; 13:53630-53645. [PMID: 34735127 DOI: 10.1021/acsami.1c16989] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Human immunodeficiency virus type 1 (HIV-1) infection remains one of the worst crises in global health. The prevention of HIV-1 infection is a crucial task that needs to be addressed due to the absence of a licensed vaccine against HIV-1. DNA vaccines present a promising alternative approach to combat HIV-1 infection due to their excellent safety profile, lack of severe side effects, and relatively rapid fabrication. Traditional vaccines composed of a monomeric envelope or peptide fragments have been indicated to lack protective efficacy mediated by inducing HIV-1-specific neutralizing antibodies in clinical trials. The immunogenicity and protection against HIV-1 induced by DNA vaccines are limited due to the poor uptake of these vaccines by antigen-presenting cells and their ready degradation by DNases and lysosomes. To address these issues of naked DNA vaccines, we described the feasibility of CpG-functionalized silica-coated calcium phosphate nanoparticles (SCPs) for efficiently delivering DNA-based HIV-1 trimeric envelope vaccines against HIV-1. Vaccines comprising the soluble BG505 SOSIP.664 trimer fused to the GCN4-based isoleucine zipper or bacteriophage T4 fibritin foldon motif with excellent simulation of the native HIV-1 envelope were chosen as trimer-based vaccine platforms. Our results showed that SCP-based DNA immunization could significantly induce both broad humoral immune responses and potent cellular immune responses compared to naked DNA vaccination in vivo. To the best of our knowledge, this study is the first to assess the feasibility of CpG-functionalized SCPs for efficiently delivering DNA vaccines expressing a native-like HIV-1 trimer. These CpG-functionalized SCPs for delivering DNA-based HIV-1 trimeric envelope vaccines may lead to the development of promising vaccine candidates against HIV-1.
Collapse
Affiliation(s)
- Shuang Li
- National Engineering Laboratory for AIDS Vaccine, School of Life Sciences, Jilin University, Changchun, Jilin 130012, China
| | - Bo Wang
- School of Chemistry and Life Science, Changchun University of Technology, Changchun, Jilin 130012, China
| | - Shun Jiang
- National Engineering Laboratory for AIDS Vaccine, School of Life Sciences, Jilin University, Changchun, Jilin 130012, China
| | - Yi Pan
- National Engineering Laboratory for AIDS Vaccine, School of Life Sciences, Jilin University, Changchun, Jilin 130012, China
| | - Yuhua Shi
- National Engineering Laboratory for AIDS Vaccine, School of Life Sciences, Jilin University, Changchun, Jilin 130012, China
| | - Wei Kong
- National Engineering Laboratory for AIDS Vaccine, School of Life Sciences, Jilin University, Changchun, Jilin 130012, China
- Key Laboratory for Molecular Enzymology and Engineering, The Ministry of Education, School of Life Sciences, Jilin University, Changchun, Jilin 130012, China
| | - Yaming Shan
- National Engineering Laboratory for AIDS Vaccine, School of Life Sciences, Jilin University, Changchun, Jilin 130012, China
- Key Laboratory for Molecular Enzymology and Engineering, The Ministry of Education, School of Life Sciences, Jilin University, Changchun, Jilin 130012, China
| |
Collapse
|
149
|
Pathmanapan S, Sekar M, Pandurangan AK, Anandasadagopan SK. Fabrication of Mesoporous Silica Nanoparticle-Incorporated Coaxial Nanofiber for Evaluating the In Vitro Osteogenic Potential. Appl Biochem Biotechnol 2021; 194:302-322. [PMID: 34762271 DOI: 10.1007/s12010-021-03741-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Accepted: 10/21/2021] [Indexed: 11/25/2022]
Abstract
The most important role of tissue engineering is to develop a biomaterial with a property that mimics the extracellular matrix (ECM) by enhancing the lineage-specific proliferation and differentiation with favorable regeneration property to aid in new tissue formation. Thus, to develop an ideal scaffold for bone repair, we have fabricated a composite nanofiber by the coaxial electrospinning technique. The coaxial electrospun nanofiber contains the core layer, consisting of polyvinyl alcohol (PVA) blended with oregano extract and mesoporous silica nanoparticles (PVA-OE-MSNPs), and the shell layer, consisting of poly-ε-caprolactone blended with collagen and hydroxyapatite (PCL-collagen-HAP). We evaluated the physicochemical properties of the nanofibers using X-ray diffraction (XRD), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), and Fourier transform infrared spectroscopy (FTIR). In vitro biocompatibility, cell adhesion, cell viability, and osteogenic potential were evaluated by 3-(4,5-dimethylthiazole-2-yl)-2,5-diphenlytetrazolium bromide (MTT), calcein AM, and alkaline phosphatase (ALP) activity and Alizarin Red staining in NIH 3T3/MG-63 cells. The results showed that the nanoparticle-incorporated coaxial nanofiber was observed with bead-free, continuous, and uniform fiber morphology with a mean diameter in the range of 310 ± 125 nm. From the biochemical studies, it is observed that the incorporation of nanofiber with HAP and MSNPs shows good swelling property with ideal porosity, biodegradation, and enhanced biomineralization property. In vitro results showed that the scaffolds with nanoparticles have higher cell adhesion, cell viability, ALP activity, and mineralization potential. Thus, the fabricated nanofiber could be an appropriate implantable biomaterial for bone tissue engineering.
Collapse
Affiliation(s)
- Srinivetha Pathmanapan
- Biochemistry and Biotechnology Laboratory, Central Leather Research Institute, Council of Scientific and Industrial Research (CSIR), Adyar, Chennai, 600020, India
- Department of Leather Technology, Housed at CSIR-Central Leather Research Institute, Alagappa College of Technology, Anna University, Chennai, 600020, India
| | - Mythrehi Sekar
- Biochemistry and Biotechnology Laboratory, Central Leather Research Institute, Council of Scientific and Industrial Research (CSIR), Adyar, Chennai, 600020, India
| | - Ashok Kumar Pandurangan
- School of Life Science, B.S. Abdur Rahman Crescent Institute of Science and Technology, Chennai, Tamil Nadu, India
| | - Suresh Kumar Anandasadagopan
- Biochemistry and Biotechnology Laboratory, Central Leather Research Institute, Council of Scientific and Industrial Research (CSIR), Adyar, Chennai, 600020, India.
- Academy of Scientific and Innovative Research (AcSIR), CSIR-CLRI Campus, Chennai, 600020, India.
| |
Collapse
|
150
|
Chen K, Peng X, Dang M, Tao J, Ma J, Li Z, Zheng L, Su X, Wang L, Teng Z. General Thermodynamic-Controlled Coating Method to Prepare Janus Mesoporous Nanomotors for Improving Tumor Penetration. ACS Appl Mater Interfaces 2021; 13:51297-51311. [PMID: 34668372 DOI: 10.1021/acsami.1c11838] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Artificial nanomotors are undergoing significant developments in several biomedical applications. However, current experimental strategies for producing nanomotors still have inherent drawbacks such as the requirement for expensive equipment, strict controlling of experimental conditions, and strenuous processes with several complex procedures. In this study, we describe for the first time a facile single-step thermodynamic-controlled coating method to prepare Janus mesoporous organosilica nanomotors. By controlling the total free energy of organosilica oligomers (G) from a low development level to a high level in the reaction system, the nonspontaneous nucleation on the platinum (Pt) nanosurface and the spontaneous nucleation in a solvent can be controlled, respectively. More importantly, we reveal that the molecular arrangement and contact angle of deposited organosilica on Pt cores vary with the total free energy of organosilica oligomers (G). Different values of θ would change the trend of detachment from Pt for organosilica nucleated cores and carry out diverse coating modes. These are indicated by the morphology evolution of platinum/organosilica hybrids, from naked platinum nanoparticles, evenly distributed organosilica shell/core, nonconcentric to typical Janus nanomotor. The prepared Janus mesoporous nanomotor (JMN) showed typical mesopore structures and active propelling behaviors under H2O2 stimulation. In addition, the JMN modified with hyaluronic acid exhibited excellent biocompatibility and improved tumor penetration under H2O2 stimulation. The successful construction of other nanomotor frameworks based on a gold-templated core proves the perfect applicability of the thermodynamic-coating method for the production of nanomotors. In conclusion, this work establishes a manufacturing methodology for nanomotors and drives nanomotors for promising biomedical applications.
Collapse
Affiliation(s)
- Kun Chen
- Key Laboratory for Organic Electronics and Information Displays and Institute of Advanced Materials, Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergetic Innovation Centre for Advanced Materials, Nanjing University of Posts and Telecommunications, Nanjing 210046, Jiangsu, P. R. China
- Department of Geriatrics, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen 518020, Guangdong, P. R. China
| | - Xin Peng
- Department of Radiology, Affiliated Nanjing Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008, P. R. China
- Department of Radiology, Zhongda Hospital, School of Medicine, Southeast University, Nanjing 210009, Jiangsu, P. R. China
| | - Meng Dang
- Key Laboratory for Organic Electronics and Information Displays and Institute of Advanced Materials, Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergetic Innovation Centre for Advanced Materials, Nanjing University of Posts and Telecommunications, Nanjing 210046, Jiangsu, P. R. China
| | - Jun Tao
- Key Laboratory for Organic Electronics and Information Displays and Institute of Advanced Materials, Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergetic Innovation Centre for Advanced Materials, Nanjing University of Posts and Telecommunications, Nanjing 210046, Jiangsu, P. R. China
| | - Jingbo Ma
- Department of Geriatrics, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen 518020, Guangdong, P. R. China
| | - Zhijie Li
- Department of Geriatrics, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen 518020, Guangdong, P. R. China
| | - Liuhai Zheng
- Department of Geriatrics, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen 518020, Guangdong, P. R. China
| | - Xiaodan Su
- Key Laboratory for Organic Electronics and Information Displays and Institute of Advanced Materials, Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergetic Innovation Centre for Advanced Materials, Nanjing University of Posts and Telecommunications, Nanjing 210046, Jiangsu, P. R. China
| | - Lianhui Wang
- Key Laboratory for Organic Electronics and Information Displays and Institute of Advanced Materials, Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergetic Innovation Centre for Advanced Materials, Nanjing University of Posts and Telecommunications, Nanjing 210046, Jiangsu, P. R. China
| | - Zhaogang Teng
- Key Laboratory for Organic Electronics and Information Displays and Institute of Advanced Materials, Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergetic Innovation Centre for Advanced Materials, Nanjing University of Posts and Telecommunications, Nanjing 210046, Jiangsu, P. R. China
- State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University School of Chemistry and Chemical Engineering, Nanjing 210093, Jiangsu, P. R. China
| |
Collapse
|