1
|
Gonzalez G, Nelson AC, Holman AR, Whitehead AJ, LaMontagne E, Lian R, Vatsyayan R, Dayeh SA, Engler AJ. Conductive electrospun polymer improves stem cell-derived cardiomyocyte function and maturation. Biomaterials 2023; 302:122363. [PMID: 37898021 PMCID: PMC10841997 DOI: 10.1016/j.biomaterials.2023.122363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 10/16/2023] [Accepted: 10/20/2023] [Indexed: 10/30/2023]
Abstract
Despite numerous efforts to generate mature human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs), cells often remain immature, electrically isolated, and may not reflect adult biology. Conductive polymers are attractive candidates to facilitate electrical communication between hPSC-CMs, especially at sub-confluent cell densities or diseased cells lacking cell-cell junctions. Here we electrospun conductive polymers to create a conductive fiber mesh and assess if electrical signal propagation is improved in hPSC-CMs seeded on the mesh network. Matrix characterization indicated fiber structure remained stable over weeks in buffer, scaffold stiffness remained near in vivo cardiac stiffness, and electrical conductivity scaled with conductive polymer concentration. Cells remained adherent and viable on the scaffolds for at least 5 days. Transcriptomic profiling of hPSC-CMs cultured on conductive substrates for 3 days showed upregulation of cardiac and muscle-related genes versus non-conductive fibers. Structural proteins were more organized and calcium handling was improved on conductive substrates, even at sub-confluent cell densities; prolonged culture on conductive scaffolds improved membrane depolarization compared to non-conductive substrates. Taken together, these data suggest that blended, conductive scaffolds are stable, supportive of electrical coupling in hPSC-CMs, and promote maturation, which may improve our ability to model cardiac diseases and develop targeted therapies.
Collapse
Affiliation(s)
- Gisselle Gonzalez
- Shu Chien-Gene Lay Department of Bioengineering, La Jolla, CA, 92093, USA
| | - Aileena C Nelson
- Shu Chien-Gene Lay Department of Bioengineering, La Jolla, CA, 92093, USA
| | - Alyssa R Holman
- Biomedical Sciences Graduate Program, La Jolla, CA, 92093, USA
| | | | - Erin LaMontagne
- Shu Chien-Gene Lay Department of Bioengineering, La Jolla, CA, 92093, USA
| | - Rachel Lian
- Shu Chien-Gene Lay Department of Bioengineering, La Jolla, CA, 92093, USA
| | - Ritwik Vatsyayan
- Department of Electrical and Computer Engineering, University California San Diego, La Jolla, CA, 92093, USA
| | - Shadi A Dayeh
- Department of Electrical and Computer Engineering, University California San Diego, La Jolla, CA, 92093, USA
| | - Adam J Engler
- Shu Chien-Gene Lay Department of Bioengineering, La Jolla, CA, 92093, USA; Biomedical Sciences Graduate Program, La Jolla, CA, 92093, USA; Sanford Consortium for Regenerative Medicine, La Jolla, CA, 92037, USA.
| |
Collapse
|
2
|
Seiti M, Giuri A, Corcione CE, Ferraris E. Advancements in tailoring PEDOT: PSS properties for bioelectronic applications: A comprehensive review. BIOMATERIALS ADVANCES 2023; 154:213655. [PMID: 37866232 DOI: 10.1016/j.bioadv.2023.213655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 09/22/2023] [Accepted: 10/06/2023] [Indexed: 10/24/2023]
Abstract
In the field of bioelectronics, the demand for biocompatible, stable, and electroactive materials for functional biological interfaces, sensors, and stimulators, is drastically increasing. Conductive polymers (CPs) are synthetic materials, which are gaining increasing interest mainly due to their outstanding electrical, chemical, mechanical, and optical properties. Since its discovery in the late 1980s, the CP Poly(3,4-ethylenedioxythiophene):poly(styrene sulfonic acid) (PEDOT:PSS) has become extremely attractive, being considered as one of the most capable organic electrode materials for several bioelectronic applications in the field of tissue engineering and regenerative medicine. Main examples refer to thin, flexible films, electrodes, hydrogels, scaffolds, and biosensors. Within this context, the authors contend that PEDOT:PSS properties should be customized to encompass: i) biocompatibility, ii) conductivity, iii) stability in wet environment, iv) adhesion to the substrate, and, when necessary, v) (bio-)degradability. However, consolidating all these properties into a single functional solution is not always straightforward. Therefore, the objective of this review paper is to present various methods for acquiring and improving PEDOT:PSS properties, with the primary focus on ensuring its biocompatibility, and simultaneously addressing the other functional features. The last section highlights a collection of designated studies, with a particular emphasis on PEDOT:PSS/carbon filler composites due to their exceptional characteristics.
Collapse
Affiliation(s)
- Miriam Seiti
- Department of Mechanical Engineering, KU Leuven, KU Leuven Campus De Nayer, Jan De Nayerlaan 5, Sint-Katelijne-Waver 2860, Belgium
| | - Antonella Giuri
- CNR-NANOTEC-Istituto di Nanotecnologia, Polo di Nanotecnologia, c/o Campus Ecotekne, via Monteroni, I-73100 Lecce, Italy
| | | | - Eleonora Ferraris
- Department of Mechanical Engineering, KU Leuven, KU Leuven Campus De Nayer, Jan De Nayerlaan 5, Sint-Katelijne-Waver 2860, Belgium.
| |
Collapse
|
3
|
Robinson DA, Foster ME, Bennett CH, Bhandarkar A, Webster ER, Celebi A, Celebi N, Fuller EJ, Stavila V, Spataru CD, Ashby DS, Marinella MJ, Krishnakumar R, Allendorf MD, Talin AA. Tunable Intervalence Charge Transfer in Ruthenium Prussian Blue Analog Enables Stable and Efficient Biocompatible Artificial Synapses. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2207595. [PMID: 36437049 DOI: 10.1002/adma.202207595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 11/16/2022] [Indexed: 06/16/2023]
Abstract
Emerging concepts for neuromorphic computing, bioelectronics, and brain-computer interfacing inspire new research avenues aimed at understanding the relationship between oxidation state and conductivity in unexplored materials. This report expands the materials playground for neuromorphic devices to include a mixed valence inorganic 3D coordination framework, a ruthenium Prussian blue analog (RuPBA), for flexible and biocompatible artificial synapses that reversibly switch conductance by more than four orders of magnitude based on electrochemically tunable oxidation state. The electrochemically tunable degree of mixed valency and electronic coupling between N-coordinated Ru sites controls the carrier concentration and mobility, as supported by density functional theory computations and application of electron transfer theory to in situ spectroscopy of intervalence charge transfer. Retention of programmed states is improved by nearly two orders of magnitude compared to extensively studied organic polymers, thus reducing the frequency, complexity, and energy costs associated with error correction schemes. This report demonstrates dopamine-mediated plasticity of RuPBA synapses and biocompatibility of RuPBA with neuronal cells, evoking prospective application for brain-computer interfacing.
Collapse
Affiliation(s)
| | | | | | | | | | - Aleyna Celebi
- Sandia National Laboratories, Livermore, CA, 94550, USA
| | - Nisa Celebi
- Sandia National Laboratories, Livermore, CA, 94550, USA
| | | | | | | | - David S Ashby
- Sandia National Laboratories, Livermore, CA, 94550, USA
| | - Matthew J Marinella
- School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ, 85281, USA
| | | | | | - A Alec Talin
- Sandia National Laboratories, Livermore, CA, 94550, USA
| |
Collapse
|
4
|
Casella A, Panitch A, Leach JK. Electroconductive agarose hydrogels modulate mesenchymal stromal cell adhesion and spreading through protein adsorption. J Biomed Mater Res A 2023; 111:596-608. [PMID: 36680496 PMCID: PMC10023318 DOI: 10.1002/jbm.a.37503] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 12/14/2022] [Accepted: 01/10/2023] [Indexed: 01/22/2023]
Abstract
Electrically conductive biomaterials direct cell behavior by capitalizing on the effect of bioelectricity in tissue homeostasis and healing. Many studies have leveraged conductive biomaterials to influence cells and improve tissue healing, even in the absence of external stimulation. However, most studies using electroactive materials neglect characterizing how the inclusion of conductive additives affects the material's mechanical properties, and the interplay between substrate electrical and mechanical properties on cell behavior is poorly understood. Furthermore, mechanisms dictating how electrically conductive materials affect cell behavior in the absence of external stimulation are not explicit. In this study, we developed a mechanically and electrically tunable conductive hydrogel using agarose and the conductive polymer PEDOT:PSS. Under certain conditions, we observed that the hydrogel physical and electrical properties were decoupled. We then seeded human mesenchymal stromal cells (MSCs) onto the hydrogels and observed enhanced adhesion and spreading of MSCs on conductive substrates, regardless of the hydrogel mechanical properties, and despite the gels having no cell-binding sites. To explain this observation, we measured protein interaction with the gels and found that charged proteins adsorbed significantly more to conductive hydrogels. These data demonstrate that conductivity promotes cell adhesion, likely by facilitating increased adsorption of proteins associated with cell binding, providing a better understanding of the mechanism of action of electrically conductive materials.
Collapse
Affiliation(s)
- Alena Casella
- Department of Biomedical Engineering, University of California Davis, Davis, CA 95616
- Department of Orthopaedic Surgery, School of Medicine, UC Davis Health, Sacramento, CA 95817
| | - Alyssa Panitch
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332
- Department of Biomedical Engineering, Emory University, Atlanta, GA 30322
| | - J. Kent Leach
- Department of Biomedical Engineering, University of California Davis, Davis, CA 95616
- Department of Orthopaedic Surgery, School of Medicine, UC Davis Health, Sacramento, CA 95817
| |
Collapse
|
5
|
Keirouz A, Mustafa YL, Turner JG, Lay E, Jungwirth U, Marken F, Leese HS. Conductive Polymer-Coated 3D Printed Microneedles: Biocompatible Platforms for Minimally Invasive Biosensing Interfaces. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2206301. [PMID: 36596657 DOI: 10.1002/smll.202206301] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 12/13/2022] [Indexed: 06/17/2023]
Abstract
Conductive polymeric microneedle (MN) arrays as biointerface materials show promise for the minimally invasive monitoring of analytes in biodevices and wearables. There is increasing interest in microneedles as electrodes for biosensing, but efforts have been limited to metallic substrates, which lack biological stability and are associated with high manufacturing costs and laborious fabrication methods, which create translational barriers. In this work, additive manufacturing, which provides the user with design flexibility and upscale manufacturing, is employed to fabricate acrylic-based microneedle devices. These microneedle devices are used as platforms to produce intrinsically-conductive, polymer-based surfaces based on polypyrrole (PPy) and poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS). These entirely polymer-based solid microneedle arrays act as dry conductive electrodes while omitting the requirement of a metallic seed layer. Two distinct coating methods of 3D-printed solid microneedles, in situ polymerization and drop casting, enable conductive functionality. The microneedle arrays penetrate ex vivo porcine skin grafts without compromising conductivity or microneedle morphology and demonstrate coating durability over multiple penetration cycles. The non-cytotoxic nature of the conductive microneedles is evaluated using human fibroblast cells. The proposed fabrication strategy offers a compelling approach to manufacturing polymer-based conductive microneedle surfaces that can be further exploited as platforms for biosensing.
Collapse
Affiliation(s)
- Antonios Keirouz
- Materials for Health Lab, Department of Chemical Engineering, University of Bath, Bath, BA2 7AY, UK
- Centre for Biosensors, Bioelectronics and Biodevices (C3Bio), University of Bath, Bath, BA2 7AY, UK
| | - Yasemin L Mustafa
- Materials for Health Lab, Department of Chemical Engineering, University of Bath, Bath, BA2 7AY, UK
- Centre for Biosensors, Bioelectronics and Biodevices (C3Bio), University of Bath, Bath, BA2 7AY, UK
| | - Joseph G Turner
- Materials for Health Lab, Department of Chemical Engineering, University of Bath, Bath, BA2 7AY, UK
- Centre for Biosensors, Bioelectronics and Biodevices (C3Bio), University of Bath, Bath, BA2 7AY, UK
| | - Emily Lay
- Department of Life Sciences, University of Bath, Bath, BA2 7AY, UK
- Centre for Therapeutic Innovation, University of Bath, Bath, BA2 7AY, UK
| | - Ute Jungwirth
- Department of Life Sciences, University of Bath, Bath, BA2 7AY, UK
- Centre for Therapeutic Innovation, University of Bath, Bath, BA2 7AY, UK
| | - Frank Marken
- Department of Chemistry, University of Bath, Claverton Down, Bath, BA2 7AY, UK
| | - Hannah S Leese
- Materials for Health Lab, Department of Chemical Engineering, University of Bath, Bath, BA2 7AY, UK
- Centre for Biosensors, Bioelectronics and Biodevices (C3Bio), University of Bath, Bath, BA2 7AY, UK
| |
Collapse
|
6
|
Gibalova A, Arndt NB, Burg L, Ravoo BJ. Light-Responsive Conductive Surface Coatings on the Basis of Azidomethyl-PEDOT Electropolymer Films. ACS APPLIED MATERIALS & INTERFACES 2023; 15:12363-12371. [PMID: 36848114 DOI: 10.1021/acsami.2c21995] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The design of responsive coatings has gained increasing attention recently, with light-responsive interfaces receiving particular appreciation, as their surface properties can be modulated with excellent spatiotemporal control. In this article, we present light-responsive conductive coatings acquired through a copper(I)-catalyzed azide-alkyne cycloaddition (CuAAC) reaction between electropolymerized azide-functionalized poly(3,4-ethylenedioxythiophene) (PEDOT-N3) and arylazopyrazole (AAP)-bearing alkynes. The UV/vis and X-ray photoelectron spectroscopy (XPS) data indicate a successful post-modification, supporting a covalent attachment of AAP moieties to PEDOT-N3. The thickness and degree of PEDOT-N3 modification are accessible by varying the amount of passed charge during electropolymerization and time of reaction, respectively, providing a degree of synthetic control over the physicochemical material properties. The produced substrates demonstrate a reversible and stable light-driven switching of photochromic properties in both "dry" and swelled states, as well as efficient electrocatalytic Z → E switching. The AAP-modified polymer substrates exhibit a light-controlled wetting behavior, demonstrating a consistently reversible switching of the static water contact angle with a difference up to 10.0° for CF3-AAP@PEDOT-N3. The results highlight the application of conducting PEDOT-N3 for the covalent immobilization of molecular switches while preserving their stimuli-responsive features.
Collapse
Affiliation(s)
- Anna Gibalova
- Organic Chemistry Institute and Center for Soft Nanoscience, Westfälische Wilhelms-Universität Münster, Corrensstr. 36, D-48149 Münster, Germany
| | - Niklas B Arndt
- Organic Chemistry Institute and Center for Soft Nanoscience, Westfälische Wilhelms-Universität Münster, Corrensstr. 36, D-48149 Münster, Germany
| | - Luca Burg
- Organic Chemistry Institute and Center for Soft Nanoscience, Westfälische Wilhelms-Universität Münster, Corrensstr. 36, D-48149 Münster, Germany
| | - Bart Jan Ravoo
- Organic Chemistry Institute and Center for Soft Nanoscience, Westfälische Wilhelms-Universität Münster, Corrensstr. 36, D-48149 Münster, Germany
| |
Collapse
|
7
|
Tringides CM, Boulingre M, Khalil A, Lungjangwa T, Jaenisch R, Mooney DJ. Tunable Conductive Hydrogel Scaffolds for Neural Cell Differentiation. Adv Healthc Mater 2023; 12:e2202221. [PMID: 36495560 PMCID: PMC10359022 DOI: 10.1002/adhm.202202221] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 11/24/2022] [Indexed: 12/14/2022]
Abstract
Multielectrode arrays would benefit from intimate engagement with neural cells, but typical arrays do not present a physical environment that mimics that of neural tissues. It is hypothesized that a porous, conductive hydrogel scaffold with appropriate mechanical and conductive properties could support neural cells in 3D, while tunable electrical and mechanical properties could modulate the growth and differentiation of the cellular networks. By incorporating carbon nanomaterials into an alginate hydrogel matrix, and then freeze-drying the formulations, scaffolds which mimic neural tissue properties are formed. Neural progenitor cells (NPCs) incorporated in the scaffolds form neurite networks which span the material in 3D and differentiate into astrocytes and myelinating oligodendrocytes. Viscoelastic and more conductive scaffolds produce more dense neurite networks, with an increased percentage of astrocytes and higher myelination. Application of exogenous electrical stimulation to the scaffolds increases the percentage of astrocytes and the supporting cells localize differently with the surrounding neurons. The tunable biomaterial scaffolds can support neural cocultures for over 12 weeks, and enable a physiologically mimicking in vitro platform to study the formation of neuronal networks. As these materials have sufficient electrical properties to be used as electrodes in implantable arrays, they may allow for the creation of biohybrid neural interfaces and living electrodes.
Collapse
Affiliation(s)
- Christina M Tringides
- Harvard Program in Biophysics, Harvard University, Cambridge, MA 02138
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02115
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA
- Harvard–MIT Division in Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA 02142
| | - Marjolaine Boulingre
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA
| | - Andrew Khalil
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02115
- Whitehead Institute of Biomedical Research, Cambridge, MA 02142
| | | | - Rudolf Jaenisch
- Whitehead Institute of Biomedical Research, Cambridge, MA 02142
- Department of Biology, Massachusetts Institute of Technology, Cambridge, MA 02142
| | - David J Mooney
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02115
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA
| |
Collapse
|
8
|
Zhang Z, Wang X, Xia H, Li H, Chen Z, Yang W. Electrical-responsive biocompatible coatings for highly corrosion-resistant and self-healing performance on AZ31 Mg alloy. J IND ENG CHEM 2023. [DOI: 10.1016/j.jiec.2023.01.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
9
|
Enhanced electrical conductivity and stretchability of ionic-liquid PEDOT:PSS air-cathodes for aluminium-air batteries with long lifetime and high specific energy. Sci Rep 2022; 12:22107. [PMID: 36543823 PMCID: PMC9772303 DOI: 10.1038/s41598-022-26546-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Accepted: 12/15/2022] [Indexed: 12/24/2022] Open
Abstract
A hydrogel film, poly-3,4-ethylenedioxythiophene (PEDOT):polystyrenesulfonate (PSS), containing an ionic liquid, is used as an air-cathode for a metal-air battery and its performance is investigated. This work presents the development of the air-cathode and the characterization of its physical, chemical and mechanical properties. Moreover, in view of wearable batteries, these air-cathodes are implemented within a flexible aluminium-air battery. It contains an aluminium anode, an electrolyte made of cellulose paper imbibed with an aqueous sodium chloride solution and the PEDOT:PSS air-cathode. Characterisation tests showed that the ionic liquid did not change the air-cathode chemically, while the electric conductivity increased considerably. The anode has an acceptable purity and was found to be resistant against self-corrosion. Discharge tests showed operating voltages up to 0.65 V, whereas two batteries in series could deliver up to 1.3 V at a current density of 0.9 mA cm-2 for almost a day, sufficient for monitoring and medical devices. Several discharge tests with current densities from 0.25 up to 2.5 mA cm-2 have presented operating lifetimes from 10 h up until over a day. At a current density of 2.8 mA cm-2, the operating voltage and lifetime dropped considerably, explained by approaching the limiting current density of about 3 mA cm-2, as evidenced by linear sweep voltammetry. The batteries showed high specific energies up to about 3140 Wh kg-1. Mechanical tests revealed a sufficient stretchability of the air-cathode, even after battery discharge, implying an acceptable degree of wearability. Together with the reusability of the air-cathode, the battery is a promising route towards a low-cost viable way for wearable power supply for monitoring medical devices with long lifetimes and high specific energies. Optimization of the air-cathode could even lead to higher power applications.
Collapse
|
10
|
Huang WC, Hung CH, Lin YW, Zheng YC, Lei WL, Lu HE. Electrically Copolymerized Polydopamine Melanin/Poly(3,4-ethylenedioxythiophene) Applied for Bioactive Multimodal Neural Interfaces with Induced Pluripotent Stem Cell-Derived Neurons. ACS Biomater Sci Eng 2022; 8:4807-4818. [PMID: 36222713 DOI: 10.1021/acsbiomaterials.2c00822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Multimodal neural interfaces include combined functions of electrical neuromodulation and synchronic monitoring of neurochemical and physiological signals in one device. The remarkable biocompatibility and electrochemical performance of polystyrene sulfonate-doped poly(3,4-ethylenedioxythiophene) (PEDOT:PSS) have made it the most recommended conductive polymer neural electrode material. However, PEDOT:PSS formed by electrochemical deposition, called PEDOT/PSS, often need multiple doping to improve structural instability in moisture, resolve the difficulties of functionalization, and overcome the poor cellular affinity. In this work, inspired by the catechol-derived adhesion and semiconductive properties of polydopamine melanin (PDAM), we used electrochemical oxidation polymerization to develop PDAM-doped PEDOT (PEDOT/PDAM) as a bioactive multimodal neural interface that permits robust electrochemical performance, structural stability, analyte-trapping capacity, and neural stem cell affinity. The use of potentiodynamic scans resolved the problem of copolymerizing 3,4-ethylenedioxythiophene (EDOT) and dopamine (DA), enabling the formation of PEDOT/PDAM self-assembled nanodomains with an ideal doping state associated with remarkable current storage and charge transfer capacity. Owing to the richness of hydrogen bond donors/acceptors provided by the hydroxyl groups of PDAM, PEDOT/PDAM presented better electrochemical and mechanical stability than PEDOT/PSS. It has also enabled high sensitivity and selectivity in the electrochemical detection of DA. Different from PEDOT/PSS, which inhibited the survival of human induced pluripotent stem cell-derived neural progenitor cells, PEDOT/PDAM maintained cell proliferation and even promoted cell differentiation into neuronal networks. Finally, PEDOT/PDAM was modified on a commercialized microelectrode array system, which resulted in the reduction of impedance by more than one order of magnitude; this significantly improved the resolution and reduced the noise of neuronal signal recording. With these advantages, PEDOT/PDAM is anticipated to be an efficient bioactive multimodal neural electrode material with potential application to brain-machine interfaces.
Collapse
Affiliation(s)
- Wei-Chen Huang
- Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu 300093, Taiwan
| | - Ching-Heng Hung
- Department of Materials Science and Engineering, National Tsing Hua University, Hsinchu 300044, Taiwan
| | - Yueh-Wen Lin
- Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu 300093, Taiwan
| | - Yu-Cheng Zheng
- Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu 300093, Taiwan
| | - Wan-Lou Lei
- Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu 300093, Taiwan
| | - Huai-En Lu
- Food Industry Research and Development Institute, Hsinchu 300, Taiwan.,Institute of Biochemistry and Molecular Biology, National Yang Ming Chiao Tung University, Hsinchu 300093, Taiwan
| |
Collapse
|
11
|
Phamornnak C, Han B, Spencer BF, Ashton MD, Blanford CF, Hardy JG, Blaker JJ, Cartmell SH. Instructive electroactive electrospun silk fibroin-based biomaterials for peripheral nerve tissue engineering. BIOMATERIALS ADVANCES 2022; 141:213094. [PMID: 36162344 DOI: 10.1016/j.bioadv.2022.213094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 07/03/2022] [Accepted: 08/22/2022] [Indexed: 10/15/2022]
Abstract
Aligned sub-micron fibres are an outstanding surface for orienting and promoting neurite outgrowth; therefore, attractive features to include in peripheral nerve tissue scaffolds. A new generation of peripheral nerve tissue scaffolds is under development incorporating electroactive materials and electrical regimes as instructive cues in order to facilitate fully functional regeneration. Herein, electroactive fibres composed of silk fibroin (SF) and poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) were developed as a novel peripheral nerve tissue scaffold. Mats of SF with sub-micron fibre diameters of 190 ± 50 nm were fabricated by double layer electrospinning with thicknesses of ∼100 μm (∼70-80 μm random fibres and ∼20-30 μm aligned fibres). Electrospun SF mats were modified with interpenetrating polymer networks (IPN) of PEDOT:PSS in various ratios of PSS/EDOT (α) and the polymerisation was assessed by hard X-ray photoelectron spectroscopy (HAXPES). The mechanical properties of electrospun SF and IPNs mats were characterised in the wet state tensile and the electrical properties were examined by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The cytotoxicity and biocompatibility of the optimal IPNs (α = 2.3 and 3.3) mats were ascertained via the growth and neurite extension of mouse neuroblastoma x rat glioma hybrid cells (NG108-15) for 7 days. The longest neurite outgrowth of 300 μm was observed in the parallel direction of fibre alignment on laminin-coated electrospun SF and IPN (α = 2.3) mats which is the material with the lowest electron transfer resistance (Ret, ca. 330 Ω). These electrically conductive composites with aligned sub-micron fibres exhibit promise for axon guidance and also have the potential to be combined with electrical stimulation treatment as a further step for the effective regeneration of nerves.
Collapse
|
12
|
Ruggiero A, Criscuolo V, Grasselli S, Bruno U, Ausilio C, Bovio CL, Bettucci O, Santoro F. Two-photon polymerization lithography enabling the fabrication of PEDOT:PSS 3D structures for bioelectronic applications. Chem Commun (Camb) 2022; 58:9790-9793. [PMID: 35971788 DOI: 10.1039/d2cc03152c] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Conductive 3D platforms have gained increasing attention in bioelectronics thanks to the improvement in the cell-chip coupling. PEDOT:PSS is nowadays widely employed in bioelectronic applications thanks to its electrical and mechanical properties. In this work, an innovative fabrication method for the realization of PEDOT:PSS-based conductive micropillars and 3D cage-like structures is presented, combining two-photon lithography and electrodeposition techniques.
Collapse
Affiliation(s)
- Amedeo Ruggiero
- Tissue Electronics, Istituto Italiano di Tecnologia, 80125 Naples, Italy. .,Faculty of Electrical Engineering and IT, RWTH Aachen, 52074, Germany.,Institute for Biological Information Processing-Bioelectronics, Forschungszentrum Juelich, 52428, Germany.
| | - Valeria Criscuolo
- Tissue Electronics, Istituto Italiano di Tecnologia, 80125 Naples, Italy.
| | - Sara Grasselli
- Tissue Electronics, Istituto Italiano di Tecnologia, 80125 Naples, Italy.
| | - Ugo Bruno
- Tissue Electronics, Istituto Italiano di Tecnologia, 80125 Naples, Italy. .,Dipartimento di Chimica, Materiali e Produzione Industriale, Università di Napoli Federico II, 80125 Naples, Italy
| | - Chiara Ausilio
- Tissue Electronics, Istituto Italiano di Tecnologia, 80125 Naples, Italy.
| | - Claudia Latte Bovio
- Tissue Electronics, Istituto Italiano di Tecnologia, 80125 Naples, Italy. .,Dipartimento di Chimica, Materiali e Produzione Industriale, Università di Napoli Federico II, 80125 Naples, Italy
| | - Ottavia Bettucci
- Tissue Electronics, Istituto Italiano di Tecnologia, 80125 Naples, Italy.
| | - Francesca Santoro
- Tissue Electronics, Istituto Italiano di Tecnologia, 80125 Naples, Italy. .,Faculty of Electrical Engineering and IT, RWTH Aachen, 52074, Germany.,Institute for Biological Information Processing-Bioelectronics, Forschungszentrum Juelich, 52428, Germany.
| |
Collapse
|
13
|
Cingolani A, Olivieri D, Messori A, Cesari C, Zanotti V, Zacchini S, Gualandi I, Scavetta E, Mariani F, Tonelli D, Mazzoni R. Electrochemical Polymerisation of Newly Synthesised 3,4-Ethylene Dioxythiophene-N-Heterocyclic Carbene Iron Complexes and Application as Redox Mediators. Inorganica Chim Acta 2022. [DOI: 10.1016/j.ica.2022.121138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
14
|
Lin CH, Luo SC. Zwitterionic Conducting Polymers: From Molecular Design, Surface Modification, and Interfacial Phenomenon to Biomedical Applications. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:7383-7399. [PMID: 35675211 DOI: 10.1021/acs.langmuir.2c00448] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Conducting polymers (CPs) have gained attention as electrode materials in bioengineering mainly because of their mechanical softness compared to conventional inorganic materials. To achieve better performance and broaden bioelectronics applications, the surface modification of soft zwitterionic polymers with antifouling properties represents a facile approach to preventing unwanted nonspecific protein adsorption and improving biocompatibility. This feature article emphasizes the antifouling properties of zwitterionic CPs, accompanied by their molecular synthesis and surface modification methods and an analysis of the interfacial phenomenon. Herein, commonly used methods for zwitterionic functionalization on CPs are introduced, including the synthesis of zwitterionic moieties on CP molecules and postsurface modification, such as the grafting of zwitterionic polymer brushes. To analyze the chain conformation, the structure of bound water in the vicinity of zwitterionic CPs and biomolecule behavior, such as protein adsorption or cell adhesion, provide critical insights into the antifouling properties. Integrating these characterization techniques offers general guidelines and paves the way for designing new zwitterionic CPs for advanced biomedical applications. Recent advances in newly designed zwitterionic CP-based electrodes have demonstrated outstanding potential in modern biomedical applications.
Collapse
Affiliation(s)
- Chia-Hsuan Lin
- Department of Materials Science and Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 10617, Taiwan
| | - Shyh-Chyang Luo
- Department of Materials Science and Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 10617, Taiwan
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes (NHRI), Miaoli County 35053, Taiwan
| |
Collapse
|
15
|
Zhao G, Zhou H, Jin G, Jin B, Geng S, Luo Z, Ge Z, Xu F. Rational Design of Electrically Conductive Biomaterials toward Excitable Tissues Regeneration. Prog Polym Sci 2022. [DOI: 10.1016/j.progpolymsci.2022.101573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
16
|
Zn-air battery with a PEDOT: PSS cathode as a viable option for wearable medical devices. J APPL ELECTROCHEM 2022. [DOI: 10.1007/s10800-022-01677-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
17
|
Electrochemically mediated multi‐modal detection strategy‐driven sensor platform to detect and quantify pesticides. ELECTROCHEMICAL SCIENCE ADVANCES 2021. [DOI: 10.1002/elsa.202100128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
|
18
|
Pitsalidis C, Pappa AM, Boys AJ, Fu Y, Moysidou CM, van Niekerk D, Saez J, Savva A, Iandolo D, Owens RM. Organic Bioelectronics for In Vitro Systems. Chem Rev 2021; 122:4700-4790. [PMID: 34910876 DOI: 10.1021/acs.chemrev.1c00539] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Bioelectronics have made strides in improving clinical diagnostics and precision medicine. The potential of bioelectronics for bidirectional interfacing with biology through continuous, label-free monitoring on one side and precise control of biological activity on the other has extended their application scope to in vitro systems. The advent of microfluidics and the considerable advances in reliability and complexity of in vitro models promise to eventually significantly reduce or replace animal studies, currently the gold standard in drug discovery and toxicology testing. Bioelectronics are anticipated to play a major role in this transition offering a much needed technology to push forward the drug discovery paradigm. Organic electronic materials, notably conjugated polymers, having demonstrated technological maturity in fields such as solar cells and light emitting diodes given their outstanding characteristics and versatility in processing, are the obvious route forward for bioelectronics due to their biomimetic nature, among other merits. This review highlights the advances in conjugated polymers for interfacing with biological tissue in vitro, aiming ultimately to develop next generation in vitro systems. We showcase in vitro interfacing across multiple length scales, involving biological models of varying complexity, from cell components to complex 3D cell cultures. The state of the art, the possibilities, and the challenges of conjugated polymers toward clinical translation of in vitro systems are also discussed throughout.
Collapse
Affiliation(s)
- Charalampos Pitsalidis
- Department of Physics, Khalifa University of Science and Technology, P.O. Box 127788, Abu Dhabi 127788, UAE.,Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| | - Anna-Maria Pappa
- Department of Biomedical Engineering, Khalifa University of Science and Technology, P.O. Box 127788, Abu Dhabi 127788, UAE
| | - Alexander J Boys
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| | - Ying Fu
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K.,Department of Pure and Applied Chemistry, Technology and Innovation Centre, University of Strathclyde, Glasgow G1 1RD, U.K
| | - Chrysanthi-Maria Moysidou
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| | - Douglas van Niekerk
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| | - Janire Saez
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K.,Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, Avenida Miguel de Unamuno, 3, 01006 Vitoria-Gasteiz, Spain.,Ikerbasque, Basque Foundation for Science, E-48011 Bilbao, Spain
| | - Achilleas Savva
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| | - Donata Iandolo
- INSERM, U1059 Sainbiose, Université Jean Monnet, Mines Saint-Étienne, Université de Lyon, 42023 Saint-Étienne, France
| | - Róisín M Owens
- Department of Chemical Engineering and Biotechnology, University of Cambridge Philippa Fawcett Drive, Cambridge CB3 0AS, U.K
| |
Collapse
|
19
|
Yu R, Zhang H, Guo B. Conductive Biomaterials as Bioactive Wound Dressing for Wound Healing and Skin Tissue Engineering. NANO-MICRO LETTERS 2021; 14:1. [PMID: 34859323 PMCID: PMC8639891 DOI: 10.1007/s40820-021-00751-y] [Citation(s) in RCA: 212] [Impact Index Per Article: 70.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 10/29/2021] [Indexed: 05/06/2023]
Abstract
Conductive biomaterials based on conductive polymers, carbon nanomaterials, or conductive inorganic nanomaterials demonstrate great potential in wound healing and skin tissue engineering, owing to the similar conductivity to human skin, good antioxidant and antibacterial activities, electrically controlled drug delivery, and photothermal effect. However, a review highlights the design and application of conductive biomaterials for wound healing and skin tissue engineering is lacking. In this review, the design and fabrication methods of conductive biomaterials with various structural forms including film, nanofiber, membrane, hydrogel, sponge, foam, and acellular dermal matrix for applications in wound healing and skin tissue engineering and the corresponding mechanism in promoting the healing process were summarized. The approaches that conductive biomaterials realize their great value in healing wounds via three main strategies (electrotherapy, wound dressing, and wound assessment) were reviewed. The application of conductive biomaterials as wound dressing when facing different wounds including acute wound and chronic wound (infected wound and diabetic wound) and for wound monitoring is discussed in detail. The challenges and perspectives in designing and developing multifunctional conductive biomaterials are proposed as well.
Collapse
Affiliation(s)
- Rui Yu
- State Key Laboratory for Mechanical Behavior of Materials, and Frontier Institute of Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China
| | - Hualei Zhang
- State Key Laboratory for Mechanical Behavior of Materials, and Frontier Institute of Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China
| | - Baolin Guo
- State Key Laboratory for Mechanical Behavior of Materials, and Frontier Institute of Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China.
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China.
| |
Collapse
|
20
|
Wang Z, Guo Y, Zhang P. A rapid quantitation of cell attachment and spreading based on digital image analysis: Application for cell affinity and compatibility assessment of synthetic polymers. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 128:112267. [PMID: 34474826 DOI: 10.1016/j.msec.2021.112267] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 06/02/2021] [Accepted: 06/14/2021] [Indexed: 11/26/2022]
Abstract
Accurate and rapid quantitation of cell attachment, spreading, and growth on a polymer thin film coated glass cover slide was developed by analyzing the digital images of cells stained with dyes. A biodegradable block copolymer poly(ethylene glycol)-block-poly(l-lactide-co-2-methyl-2-carboxyl-propylene carbonate) [PEG-b-P(LA-co-MCC)] was synthesized as model polymer with poly(L-lactic acid) [PLLA] as a control polymer. Only a small quantity of polymer (~5 mg) was needed in this method through dissolving in a solvent and casting on cover slides which were previously modified with dimethyl dichlorosilane (DMDC). Then it was seeded with cells and taken pictures with a digital camera under an optical microscope and analyzed with ImageJ software. Cell number and a series of morphological data were obtained, including cell area, circularity, perimeter and Feret's diameter, etc. The quantitative analysis results indicated that cells preferred to attach and spread on the surface of the copolymer PEG-b-P(LA-co-MCC) compared to PLLA during 24 h of cell culture. This efficient procedure provides a series of convincing statistical data to evaluate the direct interaction between cells and polymers with only an optical microscope, a digital camera and ImageJ software. It's a rapid, economic way for assessing cell affinity and compatibility of novel synthetic polymers by cell culture in vitro.
Collapse
Affiliation(s)
- Zongliang Wang
- Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China
| | - Yueming Guo
- Department of Orthopaedics, Foshan Hospital of Traditional Chinese Medicine, Foshan 528000, PR China.
| | - Peibiao Zhang
- Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China.
| |
Collapse
|
21
|
Functionalization Strategies of PEDOT and PEDOT:PSS Films for Organic Bioelectronics Applications. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9080212] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Organic bioelectronics involves the connection of organic semiconductors with living organisms, organs, tissues, cells, membranes, proteins, and even small molecules. In recent years, this field has received great interest due to the development of all kinds of devices architectures, enabling the detection of several relevant biomarkers, the stimulation and sensing of cells and tissues, and the recording of electrophysiological signals, among others. In this review, we discuss recent functionalization approaches for PEDOT and PEDOT:PSS films with the aim of integrating biomolecules for the fabrication of bioelectronics platforms. As the choice of the strategy is determined by the conducting polymer synthesis method, initially PEDOT and PEDOT:PSS films preparation methods are presented. Later, a wide variety of PEDOT functionalization approaches are discussed, together with bioconjugation techniques to develop efficient organic-biological interfaces. Finally, and by making use of these approaches, the fabrication of different platforms towards organic bioelectronics devices is reviewed.
Collapse
|
22
|
Zhou Y, Liu E, Müller H, Cui B. Optical Electrophysiology: Toward the Goal of Label-Free Voltage Imaging. J Am Chem Soc 2021; 143:10482-10499. [PMID: 34191488 PMCID: PMC8514153 DOI: 10.1021/jacs.1c02960] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Measuring and monitoring the electrical signals transmitted between neurons is key to understanding the communication between neurons that underlies human perception, information processing, and decision-making. While electrode-based electrophysiology has been the gold standard, optical electrophysiology has opened up a new area in the past decade. Voltage-dependent fluorescent reporters enable voltage imaging with high spatial resolution and flexibility to choose recording locations. However, they exhibit photobleaching as well as phototoxicity and may perturb the physiology of the cell. Label-free optical electrophysiology seeks to overcome these hurdles by detecting electrical activities optically, without the incorporation of exogenous fluorophores in cells. For example, electrochromic optical recording detects neuroelectrical signals via a voltage-dependent color change of extracellular materials, and interferometric optical recording monitors membrane deformations that accompany electrical activities. Label-free optical electrophysiology, however, is in an early stage, and often has limited sensitivity and temporal resolution. In this Perspective, we review the recent progress to overcome these hurdles. We hope this Perspective will inspire developments of label-free optical electrophysiology techniques with high recording sensitivity and temporal resolution in the near future.
Collapse
Affiliation(s)
- Yuecheng Zhou
- Department of Chemistry, Stanford University, S285 ChEM-H/Wu Tsai Neuroscience Research Complex, Stanford, California 94305, United States
| | - Erica Liu
- Department of Chemistry, Stanford University, S285 ChEM-H/Wu Tsai Neuroscience Research Complex, Stanford, California 94305, United States
| | - Holger Müller
- Department of Physics, University of California, 366 LeConte Hall, Berkeley, California 94720, United States
- Molecular Biophysics and Integrated Bioimaging, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Bianxiao Cui
- Department of Chemistry, Stanford University, S285 ChEM-H/Wu Tsai Neuroscience Research Complex, Stanford, California 94305, United States
| |
Collapse
|
23
|
Molina BG, Valle LJ, Casanovas J, Lanzalaco S, Pérez‐Madrigal MM, Turon P, Armelin E, Alemán C. Plasma-Functionalized Isotactic Polypropylene Assembled with Conducting Polymers for Bacterial Quantification by NADH Sensing. Adv Healthc Mater 2021; 10:e2100425. [PMID: 33893723 DOI: 10.1002/adhm.202100425] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2021] [Indexed: 01/08/2023]
Abstract
Rapid detection of bacterial presence on implantable medical devices is essential to prevent biofilm formation, which consists of densely packed bacteria colonies able to withstand antibiotic-mediated killing. In this work, a smart approach is presented to integrate electrochemical sensors for detecting bacterial infections in biomedical implants made of isotactic polypropylene (i-PP) using chemical assembly. The electrochemical detection is based on the capacity of conducting polymers (CPs) to detect extracellular nicotinamide adenine dinucleotide (NADH) released from cellular respiration of bacteria, which allows distinguishing prokaryotic from eukaryotic cells. Oxygen plasma-functionalized free-standing i-PP, coated with a layer (≈1.1 µm in thickness) of CP nanoparticles obtained by oxidative polymerization, is used as working electrode for the anodic polymerization of a second CP layer (≈8.2 µm in thickness), which provides very high electrochemical activity and stability. The resulting layered material, i-PPf /CP2 , detects the electro-oxidation of NADH in physiological media with a sensitivity 417 µA cm-2 and a detection limit up to 0.14 × 10-3 m, which is below the concentration of extracellular NADH found for bacterial cultures of biofilm-positive and biofilm-negative strains.
Collapse
Affiliation(s)
- Brenda G. Molina
- Departament d'Enginyeria Química and Barcelona Research Center in Multiscale Science and Engineering EEBE Universitat Politècnica de Catalunya C/Eduard Maristany, 10–14 Barcelona 08019 Spain
| | - Luis J. Valle
- Departament d'Enginyeria Química and Barcelona Research Center in Multiscale Science and Engineering EEBE Universitat Politècnica de Catalunya C/Eduard Maristany, 10–14 Barcelona 08019 Spain
| | - Jordi Casanovas
- Departament de Química Universitat de Lleida Escola Politècnica Superior C/ Jaume II no. 69 Lleida E‐25001 Spain
| | - Sonia Lanzalaco
- Departament d'Enginyeria Química and Barcelona Research Center in Multiscale Science and Engineering EEBE Universitat Politècnica de Catalunya C/Eduard Maristany, 10–14 Barcelona 08019 Spain
| | - Maria M. Pérez‐Madrigal
- Departament d'Enginyeria Química and Barcelona Research Center in Multiscale Science and Engineering EEBE Universitat Politècnica de Catalunya C/Eduard Maristany, 10–14 Barcelona 08019 Spain
- Institute for Bioengineering of Catalonia (IBEC) The Barcelona Institute of Science and Technology Baldiri Reixac 10–12 Barcelona 08028 Spain
| | - Pau Turon
- B. Braun Surgical S.A.U. Carretera de Terrassa 121, Rubí Barcelona 08191 Spain
| | - Elaine Armelin
- Departament d'Enginyeria Química and Barcelona Research Center in Multiscale Science and Engineering EEBE Universitat Politècnica de Catalunya C/Eduard Maristany, 10–14 Barcelona 08019 Spain
| | - Carlos Alemán
- Departament d'Enginyeria Química and Barcelona Research Center in Multiscale Science and Engineering EEBE Universitat Politècnica de Catalunya C/Eduard Maristany, 10–14 Barcelona 08019 Spain
- Institute for Bioengineering of Catalonia (IBEC) The Barcelona Institute of Science and Technology Baldiri Reixac 10–12 Barcelona 08028 Spain
| |
Collapse
|
24
|
Mariani F, Serafini M, Gualandi I, Arcangeli D, Decataldo F, Possanzini L, Tessarolo M, Tonelli D, Fraboni B, Scavetta E. Advanced Wound Dressing for Real-Time pH Monitoring. ACS Sens 2021; 6:2366-2377. [PMID: 34076430 PMCID: PMC8294608 DOI: 10.1021/acssensors.1c00552] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 05/24/2021] [Indexed: 12/16/2022]
Abstract
The rapid evolution of wearable technologies is giving rise to a strong push for textile chemical sensors design targeting the real-time collection of vital parameters for improved healthcare. Among the most promising applications, monitoring of nonhealing wounds is a scarcely explored medical field that still lacks quantitative tools for the management of the healing process. In this work, a smart bandage is developed for the real-time monitoring of wound pH, which has been reported to correlate with the healing stages, thus potentially giving direct access to the wound status without disturbing the wound bed. The fully textile device is realized by integrating a sensing layer, including the two-terminal pH sensor made of a semiconducting polymer and iridium oxide particles, and an absorbent layer ensuring the delivery of a continuous wound exudate flow across the sensor area. The two-terminal sensor exhibits a reversible response with a sensitivity of (59 ± 4) μA pH-1 in the medically relevant pH range for wound monitoring (pH 6-9), and its performance is not substantially affected either by the presence of the most common chemical interferents or by temperature gradients from 22 to 40 °C. Thanks to the robust sensing mechanism based on potentiometric transduction and the simple device geometry, the fully assembled smart bandage was successfully validated in flow analysis using synthetic wound exudate.
Collapse
Affiliation(s)
- Federica Mariani
- Dipartimento
di Chimica Industriale “Toso Montanari”, Università di Bologna, Viale del Risorgimento 4, 40136 Bologna, Italy
| | - Martina Serafini
- Dipartimento
di Chimica Industriale “Toso Montanari”, Università di Bologna, Viale del Risorgimento 4, 40136 Bologna, Italy
| | - Isacco Gualandi
- Dipartimento
di Chimica Industriale “Toso Montanari”, Università di Bologna, Viale del Risorgimento 4, 40136 Bologna, Italy
| | - Danilo Arcangeli
- Dipartimento
di Chimica Industriale “Toso Montanari”, Università di Bologna, Viale del Risorgimento 4, 40136 Bologna, Italy
| | - Francesco Decataldo
- Dipartimento
di Fisica e Astronomia, Università di Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy
| | - Luca Possanzini
- Dipartimento
di Fisica e Astronomia, Università di Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy
| | - Marta Tessarolo
- Dipartimento
di Fisica e Astronomia, Università di Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy
| | - Domenica Tonelli
- Dipartimento
di Chimica Industriale “Toso Montanari”, Università di Bologna, Viale del Risorgimento 4, 40136 Bologna, Italy
| | - Beatrice Fraboni
- Dipartimento
di Fisica e Astronomia, Università di Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy
| | - Erika Scavetta
- Dipartimento
di Chimica Industriale “Toso Montanari”, Università di Bologna, Viale del Risorgimento 4, 40136 Bologna, Italy
| |
Collapse
|
25
|
Korupalli C, Li H, Nguyen N, Mi F, Chang Y, Lin Y, Sung H. Conductive Materials for Healing Wounds: Their Incorporation in Electroactive Wound Dressings, Characterization, and Perspectives. Adv Healthc Mater 2021; 10:e2001384. [PMID: 33274846 DOI: 10.1002/adhm.202001384] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 11/06/2020] [Indexed: 12/11/2022]
Abstract
The use of conductive materials to promote the activity of electrically responsive cells is an effective means of accelerating wound healing. This article focuses on recent advancements in conductive materials, with emphasis on overviewing their incorporation with non-conducting polymers to fabricate electroactive wound dressings. The characteristics of these electroactive dressings are deliberated, and the mechanisms on how they accelerate the wound healing process are discussed. Potential directions for the future development of electroactive wound dressings and their potential in monitoring the course of wound healing in vivo concomitantly are also proposed.
Collapse
Affiliation(s)
- Chiranjeevi Korupalli
- Department of Chemical Engineering and Frontier Research Center on Fundamental and Applied Sciences of Matters National Tsing Hua University Hsinchu Taiwan 300 ROC
| | - Hui Li
- Department of Chemical Engineering and Frontier Research Center on Fundamental and Applied Sciences of Matters National Tsing Hua University Hsinchu Taiwan 300 ROC
| | - Nhien Nguyen
- Department of Chemical Engineering and Frontier Research Center on Fundamental and Applied Sciences of Matters National Tsing Hua University Hsinchu Taiwan 300 ROC
| | - Fwu‐Long Mi
- Department of Biochemistry and Molecular Cell Biology School of Medicine College of Medicine Taipei Medical University Taipei Taiwan 110 ROC
| | - Yen Chang
- Taipei Tzu Chi Hospital Buddhist Tzu Chi Medical Foundation and School of Medicine Tzu Chi University Hualien Taiwan 970 ROC
| | - Yu‐Jung Lin
- Department of Chemical Engineering and Frontier Research Center on Fundamental and Applied Sciences of Matters National Tsing Hua University Hsinchu Taiwan 300 ROC
- Research Center for Applied Sciences Academia Sinica Taipei Taiwan 11529 ROC
| | - Hsing‐Wen Sung
- Department of Chemical Engineering and Frontier Research Center on Fundamental and Applied Sciences of Matters National Tsing Hua University Hsinchu Taiwan 300 ROC
| |
Collapse
|
26
|
Yang X, Li X, Khochare SD, Ruchhoeft P, Shih WC, Shan X. Imaging the Electrochemical Impedance of Single Cells via Conductive Polymer Thin Film. ACS Sens 2021; 6:485-492. [PMID: 33251805 DOI: 10.1021/acssensors.0c02051] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Many fundamentally important biological phenomena involve the cells to establish and break down the adhesive interactions with the substrate. Here, we report a novel optical method that could directly image the electrochemical impedance of cell-substrate interactions at the single cell level with conventional microscopes and cameras. A thin conductive polymer layer on top of the ITO substrate (poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate), PEDOT:PSS) is used as the impedance imaging and sensing layer. A sinusoidal electrochemical potential is applied to the conductive polymer film, and the ion intercalation and transportation in the PEDOT:PSS layer will change the absorption spectrum of the polymer film. The attachment of the cells to the substrate will block and affect the ion doping and dedoping process, and therefore change the color of the polymer film. This process can be captured by any upright or inverted microscope with a simple camera. Utilizing this method, we have successfully imaged the impedance of single-cell attachment, observed the variations of cell-substrate interactions, and measured the impedance changes at different stages of the attachment process. This paper has proposed and successfully demonstrated a new strategy that translates the electrochemical impedance information to an optical signal that could be imaged and used to quantify the local responses. In addition, this method does not need any specially designed optical setup, which may lead to its broad applications in the clinics and biological research laboratories.
Collapse
Affiliation(s)
- Xu Yang
- Department of Electrical & Computer Engineering, University of Houston 4800 Calhoun Road, Houston, Texas 77004, United States
| | - Xiaoliang Li
- Department of Electrical & Computer Engineering, University of Houston 4800 Calhoun Road, Houston, Texas 77004, United States
| | - Suraj D. Khochare
- Department of Electrical & Computer Engineering, University of Houston 4800 Calhoun Road, Houston, Texas 77004, United States
| | - Paul Ruchhoeft
- Department of Electrical & Computer Engineering, University of Houston 4800 Calhoun Road, Houston, Texas 77004, United States
| | - Wei-Chuan Shih
- Department of Electrical & Computer Engineering, University of Houston 4800 Calhoun Road, Houston, Texas 77004, United States
| | - Xiaonan Shan
- Department of Electrical & Computer Engineering, University of Houston 4800 Calhoun Road, Houston, Texas 77004, United States
| |
Collapse
|
27
|
Zhu J, Omura T, Wakisaka M. Biological response of protists Haematococcus lacustris and Euglena gracilis to conductive polymer poly (3,4-ethylenedioxythiophene) polystyrene sulfonate. Lett Appl Microbiol 2021; 72:619-625. [PMID: 33566365 DOI: 10.1111/lam.13459] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 12/02/2020] [Accepted: 02/05/2021] [Indexed: 01/21/2023]
Abstract
Improving the growth and pigment accumulation of microalgae by electrochemical approaches was considered a novel and promising method. In this research, we investigated the effect of conductive polymer poly (3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) dispersible in water on growth and pigment accumulation of Haematococcus lacustris and Euglena gracilis. The results revealed that effect of PEDOT:PSS was strongly cell-dependent and each cell type has its own peculiar response. For H. lacustris, the cell density in the 50 mg·l-1 treatment group increased by 50·27%, and the astaxanthin yield in the 10 mg·l-1 treatment group increased by 37·08%. However, under the high concentrations of PEDOT:PSS treatment, cell growth was significantly inhibited, and meanwhile, the smaller and more active zoospores were observed, which reflected the changes in cell life cycle and growth mode. Cell growth of E. gracilis in all the PEDOT:PSS treatment groups were notably inhibited. Chlorophyll a content in E. gracilis decreased while chlorophyll b content increased in response to the PEDOT:PSS treatment. The results laid a foundation for further development of electrochemical methods to promote microalgae growth and explore the interactions between conductive polymers and microalgae cells.
Collapse
Affiliation(s)
- J Zhu
- Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Fukuoka, Japan
| | - T Omura
- Department of Biomaterial Sciences, Graduate School of Agricultural and Life Sciences, The University of Tokyo, Bunkyo-ku, Tokyo, Japan
| | - M Wakisaka
- Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Fukuoka, Japan
| |
Collapse
|
28
|
Puiggalí-Jou A, Cazorla E, Ruano G, Babeli I, Ginebra MP, García-Torres J, Alemán C. Electroresponsive Alginate-Based Hydrogels for Controlled Release of Hydrophobic Drugs. ACS Biomater Sci Eng 2020; 6:6228-6240. [PMID: 33449669 DOI: 10.1021/acsbiomaterials.0c01400] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Stimuli-responsive biomaterials have attracted significant attention for the construction of on-demand drug release systems. The possibility of using external stimulation to trigger drug release is particularly enticing for hydrophobic compounds, which are not easily released by simple diffusion. In this work, an electrochemically active hydrogel, which has been prepared by gelling a mixture of poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) and alginate (Alg), has been loaded with curcumin (CUR), a hydrophobic drug with a wide spectrum of clinical applications. The PEDOT/Alg hydrogel is electrochemically active and organizes as segregated PEDOT- and Alg-rich domains, explaining its behavior as an electroresponsive drug delivery system. When loaded with CUR, the hydrogel demonstrates a controlled drug release upon application of a negative electrical voltage. Comparison with the release profiles obtained applying a positive voltage and in the absence of electrical stimuli indicates that the release mechanism dominating this system is complex because of not only the intermolecular interactions between the drug and the polymeric network but also the loading of a hydrophobic drug in a water-containing delivery system.
Collapse
Affiliation(s)
- Anna Puiggalí-Jou
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Barcelona 08019, Spain.,Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya, Barcelona 08930, Spain
| | - Eric Cazorla
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Barcelona 08019, Spain
| | - Guillem Ruano
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Barcelona 08019, Spain
| | - Ismael Babeli
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Barcelona 08019, Spain
| | - Maria-Pau Ginebra
- Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya, Barcelona 08930, Spain.,Biomaterials, Biomechanics and Tissue Engineering Group, Departament de Ciència i Enginyeria de Materials, Universitat Politècnica de Catalunya (UPC), Barcelona 08930, Spain
| | - Jose García-Torres
- Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya, Barcelona 08930, Spain.,Biomaterials, Biomechanics and Tissue Engineering Group, Departament de Ciència i Enginyeria de Materials, Universitat Politècnica de Catalunya (UPC), Barcelona 08930, Spain
| | - Carlos Alemán
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/ Eduard Maristany, 10-14, Barcelona 08019, Spain.,Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya, Barcelona 08930, Spain
| |
Collapse
|
29
|
Xiao X, McGourty KD, Magner E. Enzymatic Biofuel Cells for Self-Powered, Controlled Drug Release. J Am Chem Soc 2020; 142:11602-11609. [PMID: 32510936 DOI: 10.1021/jacs.0c05749] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Self-powered drug-delivery systems based on conductive polymers (CPs) that eliminate the need for external power sources are of significant interest for use in clinical applications. Osmium redox polymer-mediated glucose/O2 enzymatic biofuel cells (EBFCs) were prepared with an additional CP-drug layer on the cathode. On discharging the EBFCs in the presence of glucose and dioxygen, model drug compounds incorporated in the CP layer were rapidly released with negligible amounts released when the EBFCs were held at open circuit. Controlled and ex situ release of three model compounds, ibuprofen (IBU), fluorescein (FLU), and 4',6-diamidino-2-phenylindole (DAPI), was achieved with this self-powered drug-release system. DAPI released in situ in cell culture media was incorporated into retinal pigment epithelium (RPE) cells. This work demonstrates a proof-of-concept responsive drug-release system that may be used in implantable devices.
Collapse
Affiliation(s)
- Xinxin Xiao
- Department of Chemical Sciences and Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland.,Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark
| | - Kieran Denis McGourty
- Department of Chemical Sciences and Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland.,Department of Chemical Sciences and Health Research Institute, University of Limerick, Limerick V94 T9PX, Ireland
| | - Edmond Magner
- Department of Chemical Sciences and Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland
| |
Collapse
|
30
|
Carli S, Di Lauro M, Bianchi M, Murgia M, De Salvo A, Prato M, Fadiga L, Biscarini F. Water-Based PEDOT:Nafion Dispersion for Organic Bioelectronics. ACS APPLIED MATERIALS & INTERFACES 2020; 12:29807-29817. [PMID: 32512998 DOI: 10.1021/acsami.0c06538] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The water dispersion of the conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrenesulfonic acid) (PEDOT:PSS) is one of the most used material precursors in organic electronics also thanks to its industrial production. There is a growing interest for conductive polymers that could be alternative surrogates or replace PEDOT:PSS in some applications. A recent study by our group compared electrodeposited PEDOT:Nafion vs PEDOT:PSS in the use for neural recordings. Here, we introduce an easy and reproducible synthetic protocol to prepare a water dispersion of PEDOT:Nafion. The conductivity of the pristine material is on the order of 2 S cm-1 and was improved up to ≈6 S cm-1 upon treatment with ethylene glycol. Faster ion transfer was assessed by electrochemical impedance spectroscopy (EIS), and, interestingly, an improved adhesion was observed for coatings of the new PEDOT:Nafion dispersion on glass substrates, even without the addition of the silane cross-linker needed for PEDOT:PSS. As proof of concept, we demonstrate the use of this novel water dispersion of PEDOT:Nafion in three different organic electronic device architectures, namely, an organic electrochemical transistor (OECT), a memristor, and an artificial synapse.
Collapse
Affiliation(s)
- Stefano Carli
- Center for Translational Neurophysiology, Istituto Italiano di Tecnologia, 44121 Ferrara, Italy
| | - Michele Di Lauro
- Center for Translational Neurophysiology, Istituto Italiano di Tecnologia, 44121 Ferrara, Italy
| | - Michele Bianchi
- Center for Translational Neurophysiology, Istituto Italiano di Tecnologia, 44121 Ferrara, Italy
| | - Mauro Murgia
- Center for Translational Neurophysiology, Istituto Italiano di Tecnologia, 44121 Ferrara, Italy
- Istituto per lo Studio dei Materiali Nanostrutturati (ISMN) CNR, 40129 Bologna, Italy
| | - Anna De Salvo
- Center for Translational Neurophysiology, Istituto Italiano di Tecnologia, 44121 Ferrara, Italy
- Section of Physiology, University of Ferrara, 44121 Ferrara, Italy
| | - Mirko Prato
- Materials Characterization Facility, Istituto Italiano di Tecnologia, 16163 Genova, Italy
| | - Luciano Fadiga
- Center for Translational Neurophysiology, Istituto Italiano di Tecnologia, 44121 Ferrara, Italy
- Section of Physiology, University of Ferrara, 44121 Ferrara, Italy
| | - Fabio Biscarini
- Center for Translational Neurophysiology, Istituto Italiano di Tecnologia, 44121 Ferrara, Italy
| |
Collapse
|
31
|
|
32
|
Tang H, Liu Z, Hu Z, Liang Y, Huang F, Cao Y. Oxoammonium enabled secondary doping of hole transporting material PEDOT:PSS for high-performance organic solar cells. Sci China Chem 2020. [DOI: 10.1007/s11426-020-9729-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
33
|
Kahoush M, Behary N, Cayla A, Mutel B, Guan J, Nierstrasz V. Influence of remote plasma on PEDOT:PSS‐coated carbon felt for improved activity of glucose oxidase. J Appl Polym Sci 2020. [DOI: 10.1002/app.48521] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- May Kahoush
- Textile Materials Technology, Department of Textile TechnologyThe Swedish School of Textiles, Faculty of Textiles, Engineering and Business, University of Borås SE‐501 90 Borås Sweden
- ENSAIT, GEMTEX – Laboratoire de Génie et Matériaux Textiles F‐59000 Lille France
- Université de Lille F‐59000 Lille Nord de France France
- College of Textile and Clothing Engineering, Soochow University Suzhou Jiangsu 215006 China
| | - Nemeshwaree Behary
- ENSAIT, GEMTEX – Laboratoire de Génie et Matériaux Textiles F‐59000 Lille France
- Université de Lille F‐59000 Lille Nord de France France
| | - Aurélie Cayla
- ENSAIT, GEMTEX – Laboratoire de Génie et Matériaux Textiles F‐59000 Lille France
- Université de Lille F‐59000 Lille Nord de France France
| | - Brigitte Mutel
- Université de Lille F‐59000 Lille Nord de France France
- IEMN, Equipe P2M, UMR 8520, Université de Lille F‐59655 Villeneuve d'Ascq France
| | - Jinping Guan
- College of Textile and Clothing Engineering, Soochow University Suzhou Jiangsu 215006 China
| | - Vincent Nierstrasz
- Textile Materials Technology, Department of Textile TechnologyThe Swedish School of Textiles, Faculty of Textiles, Engineering and Business, University of Borås SE‐501 90 Borås Sweden
| |
Collapse
|
34
|
Electrochemical quartz crystal microbalance with dissipation investigation of fibronectin adsorption dynamics driven by electrical stimulation onto a conducting and partially biodegradable copolymer. Biointerphases 2020; 15:021003. [PMID: 32197572 DOI: 10.1116/1.5144983] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Functional surface coatings are a key option for biomedical applications, from polymeric supports for tissue engineering to smart matrices for controlled drug delivery. Therefore, the synthesis of new materials for biological applications and developments is promising. Hence, biocompatible and stimuli-responsive polymers are interesting materials, especially when they present conductive properties. PEDOT-co-PDLLA graft copolymer exhibits physicochemical and mechanical characteristics required for biomedical purposes, associated with electroactive, biocompatible, and partially biodegradable properties. Herein, the study of fibronectin (FN) adsorption onto PEDOT-co-PDLLA carried out by an electrochemical quartz crystal microbalance with dissipation is reported. The amount of FN adsorbed onto PEDOT-co-PDLLA was higher than that adsorbed onto the Au surface, with a significant increase when electrical stimulation was applied (either at +0.5 or -0.125 V). Additionally, FN binds to the copolymer interface in an unfolded conformation, which can promote better NIH-3T3 fibroblast cell adhesion and later cell development.
Collapse
|
35
|
Getachew T, Mehretie S, Yip HL, Xia R, Admassie S. Roll-to-roll printed high voltage supercapattery in lead-contaminated aqueous electrolyte. Phys Chem Chem Phys 2020; 22:5597-5603. [PMID: 32100761 DOI: 10.1039/c9cp06730b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
This work investigated the potential application of roll-to-roll printed PEDOT:PSS on an ITO/PET substrate using Pb2+ containing 0.1 M NaCl aqueous solution for a supercapattery. The PEDOT:PSS/ITO/PET electrode achieved 2.2 μAh cm-2 (46.5 mAh g-1) in 0.1 M NaCl and 10 μAh cm-2 (216.8 mAh g-1) in 2 mM Pb2+/0.1 M NaCl at a current density of 0.2 mA cm-2 (4.34 A g-1). The electrode also shows good cyclic performance that retains 63% of its initial capacitance after 1000 charge-discharge cycles. A device operating at a high voltage of 1.8 V was built using PEDOT:PSS/ITO/PET in aqueous electrolyte. The energy density of the symmetric PEDOT:PSS/ITO/PET device is 6.2 Wh kg-1 in 0.1 M NaCl and is improved to 11 Wh kg-1 in 3 mM Pb2+/0.1 M NaCl.
Collapse
Affiliation(s)
- Teklewold Getachew
- Department of Chemistry, Addis Ababa University, PBox 1176, Addis Ababa, Ethiopia and State Key Laboratory of Luminescent Materials and Devices, Institute of Polymer Optoelectronic Materials and Devices, School of Materials Science and Engineering, South China University of Technology, 381 Wushan Road, Guangzhou, 510640, P. R. China.
| | - Solomon Mehretie
- Department of Chemistry, Addis Ababa University, PBox 1176, Addis Ababa, Ethiopia
| | - Hin-Lap Yip
- State Key Laboratory of Luminescent Materials and Devices, Institute of Polymer Optoelectronic Materials and Devices, School of Materials Science and Engineering, South China University of Technology, 381 Wushan Road, Guangzhou, 510640, P. R. China.
| | - Ruidong Xia
- State Key Laboratory of Luminescent Materials and Devices, Institute of Polymer Optoelectronic Materials and Devices, School of Materials Science and Engineering, South China University of Technology, 381 Wushan Road, Guangzhou, 510640, P. R. China.
| | - Shimelis Admassie
- Department of Chemistry, Addis Ababa University, PBox 1176, Addis Ababa, Ethiopia and State Key Laboratory of Luminescent Materials and Devices, Institute of Polymer Optoelectronic Materials and Devices, School of Materials Science and Engineering, South China University of Technology, 381 Wushan Road, Guangzhou, 510640, P. R. China.
| |
Collapse
|
36
|
Jewłoszewicz B, Bogdanowicz KA, Przybył W, Iwan A, Plebankiewicz I. PEDOT:PSS in Water and Toluene for Organic Devices-Technical Approach. Polymers (Basel) 2020; 12:polym12030565. [PMID: 32143387 PMCID: PMC7182892 DOI: 10.3390/polym12030565] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2020] [Accepted: 02/24/2020] [Indexed: 11/18/2022] Open
Abstract
Poly(3,4-ethylenedioxythiophene:poly(styrenesulfonate) (PEDOT:PSS) water and toluene solutions were investigated in detail, taking into consideration their stability, wettability, transparency, and electrochemical properties, along with change polarity caused by dopant. As dopant, methanol, ethanol, and isopropanol were used with different dipole moments (1.70, 1.69, and 1.66 D) and dielectric constants (33.0, 24.5, and 18.0). Three techniques, i.e., spin coating, doctor blade coating, and spray coating, were employed to created PEDOT:PSS layers on glass, glass/indium tin oxide (ITO), and glass/fluorine-doped tin oxide (FTO) substrates with optimized technical parameters for each used equipment. All used PEDOT:PSS water and toluene solutions demonstrated good wetting properties with angles below 30° for all used surfaces. Values of the energy bandgap (Eg) of PEDOT:PSS investigated by cyclic voltammetry (CV) in solution showed increase energy Eg along with addition of alcohol to the mixture, and they were found in the range of 1.20 eV to 2.85 eV. The opposite tendency was found for the Eg value of the PEDOT:PSS layer created from water solution. The storage effect on PEDOT:PSS layers detected by CV affected only the lowest unoccupied molecular orbital (LUMO) level, thereby causing changes in the energy bandgap. Finally, simple devices were constructed and investigated by infrared (IR) thermographic camera to investigate the surface defects on the created PEDOT:PSS layers. Our study showed that a more stable PEDOT:PSS layer without pin-holes and defects can be obtained from water and toluene solutions with isopropanol via the spin coating technique with an optimal speed of 3000 rpm and time of 90 s.
Collapse
|
37
|
Fu X, Wang JK, Ramírez-Pérez AC, Choong C, Lisak G. Flexible conducting polymer-based cellulose substrates for on-skin applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 108:110392. [DOI: 10.1016/j.msec.2019.110392] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 10/30/2019] [Accepted: 11/01/2019] [Indexed: 11/26/2022]
|
38
|
Inoue A, Yuk H, Lu B, Zhao X. Strong adhesion of wet conducting polymers on diverse substrates. SCIENCE ADVANCES 2020; 6:eaay5394. [PMID: 32219162 PMCID: PMC7083609 DOI: 10.1126/sciadv.aay5394] [Citation(s) in RCA: 69] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Accepted: 12/30/2019] [Indexed: 05/18/2023]
Abstract
Conducting polymers such as poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS), polypyrrole (PPy), and polyaniline (PAni) have attracted great attention as promising electrodes that interface with biological organisms. However, weak and unstable adhesion of conducting polymers to substrates and devices in wet physiological environment has greatly limited their utility and reliability. Here, we report a general yet simple method to achieve strong adhesion of various conducting polymers on diverse insulating and conductive substrates in wet physiological environment. The method is based on introducing a hydrophilic polymer adhesive layer with a thickness of a few nanometers, which forms strong adhesion with the substrate and an interpenetrating polymer network with the conducting polymer. The method is compatible with various fabrication approaches for conducting polymers without compromising their electrical or mechanical properties. We further demonstrate adhesion of wet conducting polymers on representative bioelectronic devices with high adhesion strength, conductivity, and mechanical and electrochemical stability.
Collapse
Affiliation(s)
- Akihisa Inoue
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- JSR Corporation, Tokyo 1050021, Japan
| | - Hyunwoo Yuk
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Baoyang Lu
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Flexible Electronics Innovation Institute, Jiangxi Science and Technology Normal University, Nanchang 330013, China
- School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang 330013, China
| | - Xuanhe Zhao
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Corresponding author.
| |
Collapse
|
39
|
Solazzo M, O'Brien FJ, Nicolosi V, Monaghan MG. The rationale and emergence of electroconductive biomaterial scaffolds in cardiac tissue engineering. APL Bioeng 2019; 3:041501. [PMID: 31650097 PMCID: PMC6795503 DOI: 10.1063/1.5116579] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Accepted: 09/16/2019] [Indexed: 02/07/2023] Open
Abstract
The human heart possesses minimal regenerative potential, which can often lead to chronic heart failure following myocardial infarction. Despite the successes of assistive support devices and pharmacological therapies, only a whole heart transplantation can sufficiently address heart failure. Engineered scaffolds, implantable patches, and injectable hydrogels are among the most promising solutions to restore cardiac function and coax regeneration; however, current biomaterials have yet to achieve ideal tissue regeneration and adequate integration due a mismatch of material physicochemical properties. Conductive fillers such as graphene, carbon nanotubes, metallic nanoparticles, and MXenes and conjugated polymers such as polyaniline, polypyrrole, and poly(3,4-ethylendioxythiophene) can possibly achieve optimal electrical conductivities for cardiac applications with appropriate suitability for tissue engineering approaches. Many studies have focused on the use of these materials in multiple fields, with promising effects on the regeneration of electrically active biological tissues such as orthopedic, neural, and cardiac tissue. In this review, we critically discuss the role of heart electrophysiology and the rationale toward the use of electroconductive biomaterials for cardiac tissue engineering. We present the emerging applications of these smart materials to create supportive platforms and discuss the crucial role that electrical stimulation has been shown to exert in maturation of cardiac progenitor cells.
Collapse
|
40
|
Decataldo F, Barbalinardo M, Gentili D, Tessarolo M, Calienni M, Cavallini M, Fraboni B. Organic Electrochemical Transistors for Real‐Time Monitoring of In Vitro Silver Nanoparticle Toxicity. ACTA ACUST UNITED AC 2019; 4:e1900204. [DOI: 10.1002/adbi.201900204] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 10/11/2019] [Indexed: 12/30/2022]
Affiliation(s)
- Francesco Decataldo
- Department of Physics and AstronomyAlma Mater Studiorum – University of Bologna Viale Berti Pichat 6/2 40127 Bologna Italy
| | - Marianna Barbalinardo
- Consiglio Nazionale delle RicercheIstituto per lo Studio dei Materiali Nanostrutturati (CNR‐ISMN) via P. Gobetti 101 40129 Bologna Italy
| | - Denis Gentili
- Consiglio Nazionale delle RicercheIstituto per lo Studio dei Materiali Nanostrutturati (CNR‐ISMN) via P. Gobetti 101 40129 Bologna Italy
| | - Marta Tessarolo
- Department of Physics and AstronomyAlma Mater Studiorum – University of Bologna Viale Berti Pichat 6/2 40127 Bologna Italy
| | - Maria Calienni
- Department of Physics and AstronomyAlma Mater Studiorum – University of Bologna Viale Berti Pichat 6/2 40127 Bologna Italy
| | - Massimiliano Cavallini
- Consiglio Nazionale delle RicercheIstituto per lo Studio dei Materiali Nanostrutturati (CNR‐ISMN) via P. Gobetti 101 40129 Bologna Italy
| | - Beatrice Fraboni
- Department of Physics and AstronomyAlma Mater Studiorum – University of Bologna Viale Berti Pichat 6/2 40127 Bologna Italy
| |
Collapse
|
41
|
Soares AL, Zamora ML, Marchesi LF, Vidotti M. Adsorption of catechol onto PEDOT films doped with gold nanoparticles: Electrochemical and spectroscopic studies. Electrochim Acta 2019. [DOI: 10.1016/j.electacta.2019.134773] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
42
|
Hespel L, Dupré de Baubigny J, Lalanne P, de Beco S, Coppey M, Villard C, Humblot V, Marie E, Tribet C. Redox-Triggered Control of Cell Adhesion and Deadhesion on Poly(lysine)- g-poly(ethylene oxide) Adlayers. ACS APPLIED BIO MATERIALS 2019; 2:4367-4376. [DOI: 10.1021/acsabm.9b00601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Louise Hespel
- PASTEUR, Département de Chimie, École Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005 Paris, France
| | - Julien Dupré de Baubigny
- PASTEUR, Département de Chimie, École Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005 Paris, France
| | - Pierre Lalanne
- PASTEUR, Département de Chimie, École Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005 Paris, France
| | - Simon de Beco
- Laboratoire Physico Chimie, Institut Curie, PSL Université, Sorbonne Université, CNRS UMR168, F-75005 Paris, France
| | - Mathieu Coppey
- Laboratoire Physico Chimie, Institut Curie, PSL Université, Sorbonne Université, CNRS UMR168, F-75005 Paris, France
| | - Catherine Villard
- Laboratoire Physico Chimie, Institut Curie, PSL Université, Sorbonne Université, CNRS UMR168, F-75005 Paris, France
| | - Vincent Humblot
- Laboratoire Réactivité de Surface, Sorbonne Université, CNRS UMR 7197, 4 Place Jussieu, F-75005 Paris, France
| | - Emmanuelle Marie
- PASTEUR, Département de Chimie, École Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005 Paris, France
| | - Christophe Tribet
- PASTEUR, Département de Chimie, École Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005 Paris, France
| |
Collapse
|
43
|
Sánchez-Jiménez M, Estrany F, Borràs N, Maiti B, Díaz Díaz D, Del Valle LJ, Alemán C. Antimicrobial activity of poly(3,4-ethylenedioxythiophene) n-doped with a pyridinium-containing polyelectrolyte. SOFT MATTER 2019; 15:7695-7703. [PMID: 31502620 DOI: 10.1039/c9sm01491h] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
In spite of p-doped conducting polymers having been widely studied in the last decades and many applications having been developed, studies based on n-doped conducting polymers are extremely scarce. This fact is even more evident when it comes to conducting polymers n-doped with polycations, even though polyanions, such as poly(styrenesulfonate), are often used to obtain p-doped conducting polymers. In this work poly(pyridinium-1,4-diyliminocarbonyl-1,4-phenylene-methylene chloride), abbreviated as P(Py-1,4-P), has been used to prepare n-doped poly(3,4-ethylenedioxythiophene) (PEDOT) electrodes by applying a reduction potential to a de-doped PEDOT film in a P(Py-1,4-P) water solution. The utilization of this cationic polyelectrolyte as an n-dopant agent results in drastic superficial changes, as is observed by comparing the morphology, topography and wettability of p-doped, de-doped and n-doped PEDOT. Cytotoxicity, cell adhesion and cell proliferation assays, which have been conducted using epithelial and fibroblast cell lines, show that the amount of P(Py-1,4-P) in the re-doped PEDOT films is below that required to observe a cytotoxic harmful response and that n-doped PEDOT:P(Py-1,4-P) films are biocompatible. The non-specific bacteriostatic properties of n-doped PEDOT:P(Py-1,4-P) films have been demonstrated against E. coli and S. aureus bacteria (Gram-negative and Gram-positive, respectively) using bacterial growth curves and adhesion assays. Although the bacteriostatic effect is in part due to the conducting polymer, as is proved by results for p-doped and de-doped PEDOT, the incorporation of P(Py-1,4-P) through the re-doping process greatly enhances this antimicrobial behaviour. Thus, only a small concentration of this cationic polyelectrolyte (∼0.1 mM) is needed to inhibit bacterial growth.
Collapse
Affiliation(s)
- Margarita Sánchez-Jiménez
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, Ed. I2, 08019, Barcelona, Spain.
| | - Francesc Estrany
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, Ed. I2, 08019, Barcelona, Spain. and Barcelona Research Center for Multiscale Science and Engineering, Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, Ed. C, 08019, Barcelona, Spain
| | - Núria Borràs
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, Ed. I2, 08019, Barcelona, Spain.
| | - Binoy Maiti
- Institut für Organische Chemie, Universität Regensburg, Universitätsstr. 31, 93053 Regensburg, Germany
| | - David Díaz Díaz
- Institut für Organische Chemie, Universität Regensburg, Universitätsstr. 31, 93053 Regensburg, Germany and Instituto de Productos Naturales y Agrobiología del CSIC, Avda. Astrofísico Francisco Sánchez 3, 38206 La Laguna, Tenerife, Spain
| | - Luis J Del Valle
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, Ed. I2, 08019, Barcelona, Spain. and Barcelona Research Center for Multiscale Science and Engineering, Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, Ed. C, 08019, Barcelona, Spain
| | - Carlos Alemán
- Departament d'Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, Ed. I2, 08019, Barcelona, Spain. and Barcelona Research Center for Multiscale Science and Engineering, Universitat Politècnica de Catalunya, C/Eduard Maristany, 10-14, Ed. C, 08019, Barcelona, Spain and Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, Spain
| |
Collapse
|
44
|
Zips S, Grob L, Rinklin P, Terkan K, Adly NY, Weiß LJK, Mayer D, Wolfrum B. Fully Printed μ-Needle Electrode Array from Conductive Polymer Ink for Bioelectronic Applications. ACS APPLIED MATERIALS & INTERFACES 2019; 11:32778-32786. [PMID: 31424902 DOI: 10.1021/acsami.9b11774] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Microelectrode arrays (MEAs) are widely used platforms in bioelectronics to study electrogenic cells. In recent years, the processing of conductive polymers for the fabrication of three-dimensional electrode arrays has gained increasing interest for the development of novel sensor designs. Here, additive manufacturing techniques are promising tools for the production of MEAs with three-dimensional electrodes. In this work, a facile additive manufacturing process for the fabrication of MEAs that feature needle-like electrode tips, so-called μ-needles, is presented. To this end, an aerosol-jet compatible PEDOT:PSS and multiwalled carbon nanotube composite ink with a conductivity of 323 ± 75 S m-1 is developed and used in a combined inkjet and aerosol-jet printing process to produce the μ-needle electrode features. The μ-needles are fabricated with a diameter of 10 ± 2 μm and a height of 33 ± 4 μm. They penetrate an inkjet-printed dielectric layer to a height of 12 ± 3 μm. After successful printing, the electrochemical properties of the devices are assessed via cyclic voltammetry and impedance spectroscopy. The μ-needles show a capacitance of 242 ± 70 nF at a scan rate of 5 mV s-1 and an impedance of 128 ± 22 kΩ at 1 kHz frequency. The stability of the μ-needle MEAs in aqueous electrolyte is demonstrated and the devices are used to record extracellular signals from cardiomyocyte-like HL-1 cells. This proof-of-principle experiment shows the μ-needle MEAs' cell-culture compatibility and functional integrity to investigate electrophysiological signals from living cells.
Collapse
Affiliation(s)
- Sabine Zips
- Neuroelectronics - Munich School of Bioengineering, Department of Electrical and Computer Engineering , Technical University of Munich , Boltzmannstrasse 11 , 85748 Garching , Germany
| | - Leroy Grob
- Neuroelectronics - Munich School of Bioengineering, Department of Electrical and Computer Engineering , Technical University of Munich , Boltzmannstrasse 11 , 85748 Garching , Germany
| | - Philipp Rinklin
- Neuroelectronics - Munich School of Bioengineering, Department of Electrical and Computer Engineering , Technical University of Munich , Boltzmannstrasse 11 , 85748 Garching , Germany
| | - Korkut Terkan
- Neuroelectronics - Munich School of Bioengineering, Department of Electrical and Computer Engineering , Technical University of Munich , Boltzmannstrasse 11 , 85748 Garching , Germany
| | - Nouran Yehia Adly
- Neuroelectronics - Munich School of Bioengineering, Department of Electrical and Computer Engineering , Technical University of Munich , Boltzmannstrasse 11 , 85748 Garching , Germany
| | - Lennart Jakob Konstantin Weiß
- Neuroelectronics - Munich School of Bioengineering, Department of Electrical and Computer Engineering , Technical University of Munich , Boltzmannstrasse 11 , 85748 Garching , Germany
| | - Dirk Mayer
- Institute of Complex Systems, Bioelectronics (ICS-8) , Forschungszentrum Jülich , 52425 Jülich , Germany
| | - Bernhard Wolfrum
- Neuroelectronics - Munich School of Bioengineering, Department of Electrical and Computer Engineering , Technical University of Munich , Boltzmannstrasse 11 , 85748 Garching , Germany
- Institute of Complex Systems, Bioelectronics (ICS-8) , Forschungszentrum Jülich , 52425 Jülich , Germany
| |
Collapse
|
45
|
Molina BG, Cuesta S, Besharatloo H, Roa JJ, Armelin E, Alemán C. Free-Standing Faradaic Motors Based on Biocompatible Nanoperforated Poly(lactic Acid) Layers and Electropolymerized Poly(3,4-ethylenedioxythiophene). ACS APPLIED MATERIALS & INTERFACES 2019; 11:29427-29435. [PMID: 31313896 DOI: 10.1021/acsami.9b08678] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The electro-chemo-mechanical response of robust and flexible free-standing films made of three nanoperforated poly(lactic acid) (pPLA) layers separated by two anodically polymerized poly(3,4-ethylenedioxythiophene) (PEDOT) layers has been demonstrated. The mechanical and electrochemical properties of these films, which are provided by pPLA and PEDOT, respectively, have been studied by nanoindentation, cyclic voltammetry, and galvanostatic charge-discharge assays. The unprecedented combination of properties obtained for this system is appropriated for its utilization as a Faradaic motor, also named artificial muscle. Application of square potential waves has shown important bending movements in the films, which can be repeated for more than 500 cycles without damaging its mechanical integrity. Furthermore, the actuator is able to push a huge amount of mass, as it has been proved by increasing the mass of the passive pPLA up to 328% while keeping the mass of electroactive PEDOT unaltered.
Collapse
Affiliation(s)
- Brenda G Molina
- Departament d'Enginyeria Química, EEBE , Universitat Politécnica de Catalunya , C/Eduard Maristany 10-14, Ed. I2 , 08019 Barcelona , Spain
- Barcelona Research Center for Multiscale Science and Engineering , Universitat Politècnica de Catalunya , Eduard Maristany 10-14 , 08019 Barcelona , Spain
| | - Sergi Cuesta
- Departament d'Enginyeria Química, EEBE , Universitat Politécnica de Catalunya , C/Eduard Maristany 10-14, Ed. I2 , 08019 Barcelona , Spain
- Barcelona Research Center for Multiscale Science and Engineering , Universitat Politècnica de Catalunya , Eduard Maristany 10-14 , 08019 Barcelona , Spain
| | - Hossein Besharatloo
- Barcelona Research Center for Multiscale Science and Engineering , Universitat Politècnica de Catalunya , Eduard Maristany 10-14 , 08019 Barcelona , Spain
- CIEFMA-Departament de Ciència dels Materials i Eng. Metal·lúrgica , Universitat Politècnica de Catalunya , Eduard Maristany 10-14, Ed. I , 08019 Barcelona , Spain
| | - Joan Josep Roa
- Barcelona Research Center for Multiscale Science and Engineering , Universitat Politècnica de Catalunya , Eduard Maristany 10-14 , 08019 Barcelona , Spain
- CIEFMA-Departament de Ciència dels Materials i Eng. Metal·lúrgica , Universitat Politècnica de Catalunya , Eduard Maristany 10-14, Ed. I , 08019 Barcelona , Spain
| | - Elaine Armelin
- Departament d'Enginyeria Química, EEBE , Universitat Politécnica de Catalunya , C/Eduard Maristany 10-14, Ed. I2 , 08019 Barcelona , Spain
- Barcelona Research Center for Multiscale Science and Engineering , Universitat Politècnica de Catalunya , Eduard Maristany 10-14 , 08019 Barcelona , Spain
| | - Carlos Alemán
- Departament d'Enginyeria Química, EEBE , Universitat Politécnica de Catalunya , C/Eduard Maristany 10-14, Ed. I2 , 08019 Barcelona , Spain
- Barcelona Research Center for Multiscale Science and Engineering , Universitat Politècnica de Catalunya , Eduard Maristany 10-14 , 08019 Barcelona , Spain
- Institute for Bioengineering of Catalonia (IBEC) , The Barcelona Institute of Science and Technology , Baldiri Reixac 10-12 , 08028 Barcelona , Spain
| |
Collapse
|
46
|
Wu JG, Chen JH, Liu KT, Luo SC. Engineering Antifouling Conducting Polymers for Modern Biomedical Applications. ACS APPLIED MATERIALS & INTERFACES 2019; 11:21294-21307. [PMID: 31120722 DOI: 10.1021/acsami.9b04924] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Conducting polymers are considered to be favorable electrode materials for implanted biosensors and bioelectronics, because their mechanical properties are similar to those of biological tissues such as nerve and brain tissues. However, one of the primary challenges for implanted devices is to prevent the unwanted protein adhesion or cell binding within biological fluids. The nonspecific adsorption generally causes the malfunction of implanted devices, which is problematic for long-term applications. When responding to the requirements of solving the problems caused by nonspecific adsorption, an increasing number of studies on antifouling conducting polymers has been recently published. In this review, synthetic strategies for preparing antifouling conducting polymers, including direct synthesis of functional monomers and post-functionalization, are introduced. The applications of antifouling conducting polymers in modern biomedical applications are particularly highlighted. This paper presents focuses on the features of antifouling conducting polymers and the challenges of modern biomedical applications.
Collapse
Affiliation(s)
- Jhih-Guang Wu
- Department of Materials Science and Engineering , National Taiwan University , No. 1, Sec. 4, Roosevelt Road , Taipei 10617 , Taiwan
| | - Jie-Hao Chen
- Department of Materials Science and Engineering , National Taiwan University , No. 1, Sec. 4, Roosevelt Road , Taipei 10617 , Taiwan
| | - Kuan-Ting Liu
- Department of Materials Science and Engineering , National Taiwan University , No. 1, Sec. 4, Roosevelt Road , Taipei 10617 , Taiwan
| | - Shyh-Chyang Luo
- Department of Materials Science and Engineering , National Taiwan University , No. 1, Sec. 4, Roosevelt Road , Taipei 10617 , Taiwan
- Advanced Research Center for Green Materials Science and Technology , National Taiwan University , Taipei 10617 , Taiwan
| |
Collapse
|
47
|
Application of conducting polymers to wound care and skin tissue engineering: A review. Biosens Bioelectron 2019; 135:50-63. [DOI: 10.1016/j.bios.2019.04.001] [Citation(s) in RCA: 116] [Impact Index Per Article: 23.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 03/22/2019] [Accepted: 04/01/2019] [Indexed: 01/20/2023]
|
48
|
Liu L, Choi S. A self-charging cyanobacterial supercapacitor. Biosens Bioelectron 2019; 140:111354. [PMID: 31154252 DOI: 10.1016/j.bios.2019.111354] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 05/10/2019] [Accepted: 05/24/2019] [Indexed: 12/17/2022]
Abstract
Microliter-scale photosynthetic microbial fuel cells (micro-PMFC) can be the most suitable power source for unattended environmental sensors because the technique can continuously generate electricity from microbial photosynthesis and respiration through day-night cycles, offering a clean and renewable power source with self-sustaining potential. However, the promise of this technology has not been translated into practical applications because of its relatively low performance. By creating an innovative supercapacitive micro-PMFC device with maximized bacterial photoelectrochemical activities in a well-controlled, tightly enclosed micro-chamber, this work established innovative strategies to revolutionize micro-PMFC performance to attain stable high power and current density (38 μW/cm2 and 120 μA/cm2) that then potentially provides a practical and sustainable power supply for the environmental sensing applications. The proposed technique is based on a 3-D double-functional bio-anode concurrently exhibiting bio-electrocatalytic energy harvesting and charge storing. It offers the high-energy harvesting functionality of micro-PMFCs with the high-power operation of an internal supercapacitor for charging and discharging. The performance of the supercapacitive micro-PMFC improved significantly through miniaturizing innovative device architectures and connecting multiple miniature devices in series.
Collapse
Affiliation(s)
- Lin Liu
- Bioelectronics & Microsystems Laboratory, Department of Electrical & Computer Engineering, State University of New York-Binghamton, Binghamton, NY 13902, USA
| | - Seokheun Choi
- Bioelectronics & Microsystems Laboratory, Department of Electrical & Computer Engineering, State University of New York-Binghamton, Binghamton, NY 13902, USA.
| |
Collapse
|
49
|
Zeglio E, Rutz AL, Winkler TE, Malliaras GG, Herland A. Conjugated Polymers for Assessing and Controlling Biological Functions. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1806712. [PMID: 30861237 DOI: 10.1002/adma.201806712] [Citation(s) in RCA: 88] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Revised: 01/15/2019] [Indexed: 05/20/2023]
Abstract
The field of organic bioelectronics is advancing rapidly in the development of materials and devices to precisely monitor and control biological signals. Electronics and biology can interact on multiple levels: organs, complex tissues, cells, cell membranes, proteins, and even small molecules. Compared to traditional electronic materials such as metals and inorganic semiconductors, conjugated polymers (CPs) have several key advantages for biological interactions: tunable physiochemical properties, adjustable form factors, and mixed conductivity (ionic and electronic). Herein, the use of CPs in five biologically oriented research topics, electrophysiology, tissue engineering, drug release, biosensing, and molecular bioelectronics, is discussed. In electrophysiology, implantable devices with CP coating or CP-only electrodes are showing improvements in signal performance and tissue interfaces. CP-based scaffolds supply highly favorable static or even dynamic interfaces for tissue engineering. CPs also enable delivery of drugs through a variety of mechanisms and form factors. For biosensing, CPs offer new possibilities to incorporate biological sensing elements in a conducting matrix. Molecular bioelectronics is today used to incorporate (opto)electronic functions in living tissue. Under each topic, the limits of the utility of CPs are discussed and, overall, the major challenges toward implementation of CPs and their devices to real-world applications are highlighted.
Collapse
Affiliation(s)
- Erica Zeglio
- School of Materials Science and Engineering, UNSW Sydney, Sydney, NSW, 2052, Australia
- Department of Micro and Nanosystems, KTH Royal Institute of Technology, 10044, Stockholm, Sweden
| | - Alexandra L Rutz
- Electrical Engineering Division, Department of Engineering, University of Cambridge, 9 JJ Thomson Ave., Cambridge, CB3 0FA, UK
| | - Thomas E Winkler
- Department of Micro and Nanosystems, KTH Royal Institute of Technology, 10044, Stockholm, Sweden
| | - George G Malliaras
- Electrical Engineering Division, Department of Engineering, University of Cambridge, 9 JJ Thomson Ave., Cambridge, CB3 0FA, UK
| | - Anna Herland
- Department of Micro and Nanosystems, KTH Royal Institute of Technology, 10044, Stockholm, Sweden
- Swedish Medical Nanoscience Center, Department of Neuroscience, Karolinska Institute, 17177, Stockholm, Sweden
| |
Collapse
|
50
|
Effect of monophasic pulsed stimulation on live single cell de-adhesion on conducting polymers with adsorbed fibronectin as revealed by single cell force spectroscopy. Biointerphases 2019; 14:021003. [PMID: 30925841 DOI: 10.1116/1.5082204] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The force required to detach a single fibroblast cell in contact with the conducting polymer, polypyrrole doped with dodecylbenzene, was quantified using the Atomic Force Microscope-based technique, Single Cell Force Spectroscopy. The de-adhesion force for a single cell was 0.64 ± 0.03 nN and predominately due to unbinding of α5β1 integrin complexes with surface adsorbed fibronectin, as confirmed by blocking experiments using antibodies. Monophasic pulsed stimulation (50 μs pulse duration) superimposed on either an applied oxidation (+500) or reduction (-500 mV) constant voltage caused a significant decrease in the de-adhesion force by 30%-45% to values ranging from 0.34 to 0.43 nN (±0.02 nN). The electrical stimulation caused a reduction in the molecular-level jump and plateau interactions, while an opposing increase in nonspecific interactions was observed during the cell de-adhesion process. Due to the monophasic pulsed stimulation, there is an apparent change or weakening of the cell membrane properties, which is suggested to play a role in reducing the cell de-adhesion. Based on this study, pulsed stimulation with optimized threshold parameters represents a possible approach to tune cell interactions and adhesion on conducting polymers.
Collapse
|