1
|
Cook A, Kaydanov N, Ugarte-Uribe B, Boffi JC, Kamm GB, Prevedel R, Deo C. Chemigenetic Far-Red Labels and Ca 2+ Indicators Optimized for Photoacoustic Imaging. J Am Chem Soc 2024; 146:23963-23971. [PMID: 39158696 PMCID: PMC11363013 DOI: 10.1021/jacs.4c07080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Revised: 07/31/2024] [Accepted: 08/01/2024] [Indexed: 08/20/2024]
Abstract
Photoacoustic imaging is an emerging modality with significant promise for biomedical applications such as neuroimaging, owing to its capability to capture large fields of view deep inside complex scattering tissue. However, widespread adoption of this technique has been hindered by a lack of suitable molecular reporters for this modality. In this work, we introduce chemigenetic labels and calcium sensors specifically tailored for photoacoustic imaging, using a combination of synthetic dyes and HaloTag-based self-labeling proteins. We rationally design and engineer far-red "acoustogenic" dyes, showing high photoacoustic turn-ons upon binding to HaloTag, and develop a suite of tunable calcium indicators based on these scaffolds. These first-generation photoacoustic reporters show excellent performance in tissue-mimicking phantoms, with the best variants outperforming existing sensors in terms of signal intensity, sensitivity, and photostability. We demonstrate the application of these ligands for labeling HaloTag-expressing neurons in mouse brain tissue, producing strong, specifically targeted photoacoustic signal, and provide a first example of in vivo labeling with these chemigenetic photoacoustic probes. Together, this work establishes a new approach for the design of photoacoustic reporters, paving the way toward deep tissue functional imaging.
Collapse
Affiliation(s)
- Alexander Cook
- European Molecular Biology
Laboratory, Meyerhofstraße 1, 69117 Heidelberg, Germany
| | - Nikita Kaydanov
- European Molecular Biology
Laboratory, Meyerhofstraße 1, 69117 Heidelberg, Germany
| | - Begoña Ugarte-Uribe
- European Molecular Biology
Laboratory, Meyerhofstraße 1, 69117 Heidelberg, Germany
| | - Juan Carlos Boffi
- European Molecular Biology
Laboratory, Meyerhofstraße 1, 69117 Heidelberg, Germany
| | - Gretel B. Kamm
- European Molecular Biology
Laboratory, Meyerhofstraße 1, 69117 Heidelberg, Germany
| | - Robert Prevedel
- European Molecular Biology
Laboratory, Meyerhofstraße 1, 69117 Heidelberg, Germany
| | - Claire Deo
- European Molecular Biology
Laboratory, Meyerhofstraße 1, 69117 Heidelberg, Germany
| |
Collapse
|
2
|
Hwang J, Kim B, Jin C, Lee G, Jeong H, Lee H, Noh J, Lim SJ, Kim JY, Choi H. Shortwave Infrared Imaging of a Quantum Dot-Based Magnetic Guidewire Toward Non-Fluoroscopic Peripheral Vascular Interventions. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024:e2404251. [PMID: 39175372 DOI: 10.1002/smll.202404251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 08/14/2024] [Indexed: 08/24/2024]
Abstract
Peripheral vascular interventions (PVIs) offer several benefits to patients with lower extremity arterial diseases, including reduced pain, simpler anesthesia, and shorter recovery time, compared to open surgery. However, to monitor the endovascular tools inside the body, PVIs are conducted under X-ray fluoroscopy, which poses serious long-term health risks to physicians and patients. Shortwave infrared (SWIR) imaging of quantum dots (QDs) has shown great potential in bioimaging due to the non-ionizing penetration of SWIR light through tissues. In this paper, a QD-based magnetic guidewire and its system is introduced that allows X-ray-free detection under SWIR imaging and precise steering via magnetic manipulation. The QD magnetic guidewire contains a flexible silicone tube encapsulating a QD polydimethylsiloxane (PDMS) composite, where HgCdSe/HgS/CdS/CdZnS/ZnS/SiO2 core/multi-shell QDs are dispersed in the PDMS matrix for SWIR imaging upon near-infrared excitation, as well as a permanent magnet for magnetic steering. The SWIR penetration of the QD magnetic guidewire is investigated within an artificial tissue model (1% Intralipid) and explore the potential for non-fluoroscopic PVIs within a vascular phantom model. The QD magnetic guidewire is biocompatible in its entirety, with excellent resistance to photobleaching and chemical alteration, which is a promising sign for its future clinical implementation.
Collapse
Affiliation(s)
- Junsun Hwang
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, 42988, Republic of Korea
- DGIST-ETH Microrobotics Research Center, DGIST, Daegu, 42988, Republic of Korea
- Robotics and Mechatronics Engineering Research Center, DGIST, Daegu, 42988, Republic of Korea
- Institute of Mechanical Engineering, École polytechnique fédérale de Lausanne (EPFL), Lausanne, 1015, Switzerland
| | - Beomjoo Kim
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, 42988, Republic of Korea
- DGIST-ETH Microrobotics Research Center, DGIST, Daegu, 42988, Republic of Korea
| | - Chaewon Jin
- Division of Biotechnology, DGIST, Daegu, 42988, Republic of Korea
| | - Gyudong Lee
- DGIST-ETH Microrobotics Research Center, DGIST, Daegu, 42988, Republic of Korea
- Division of Nanotechnology, DGIST, Daegu, 42988, Republic of Korea
| | - Hwajun Jeong
- DGIST-ETH Microrobotics Research Center, DGIST, Daegu, 42988, Republic of Korea
- Division of Nanotechnology, DGIST, Daegu, 42988, Republic of Korea
| | - Hyunki Lee
- DGIST-ETH Microrobotics Research Center, DGIST, Daegu, 42988, Republic of Korea
- Division of Intelligent Robotics, DGIST, Daegu, 42988, Republic of Korea
| | - Jonggu Noh
- Division of Intelligent Robotics, DGIST, Daegu, 42988, Republic of Korea
| | - Sung Jun Lim
- DGIST-ETH Microrobotics Research Center, DGIST, Daegu, 42988, Republic of Korea
- Division of Nanotechnology, DGIST, Daegu, 42988, Republic of Korea
| | - Jin-Young Kim
- DGIST-ETH Microrobotics Research Center, DGIST, Daegu, 42988, Republic of Korea
- Division of Biotechnology, DGIST, Daegu, 42988, Republic of Korea
- Department of Interdisciplinary Engineering, DGIST, Daegu, 42988, Republic of Korea
| | - Hongsoo Choi
- Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, 42988, Republic of Korea
- DGIST-ETH Microrobotics Research Center, DGIST, Daegu, 42988, Republic of Korea
- Robotics and Mechatronics Engineering Research Center, DGIST, Daegu, 42988, Republic of Korea
| |
Collapse
|
3
|
Vikas, Kumar R, Soni S. Measurement of anisotropy factor of nanoparticle embedded tumor phantoms for plasmonic photothermal therapeutics. JOURNAL OF BIOPHOTONICS 2024; 17:e202400007. [PMID: 38894568 DOI: 10.1002/jbio.202400007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 05/07/2024] [Accepted: 05/11/2024] [Indexed: 06/21/2024]
Abstract
Measurement of anisotropy factor (g) in the presence of nanoparticles (NPs) is important for understanding light distribution for plasmonic photothermal cancer therapeutics. Here, anisotropy factor is investigated through bilayer phantoms (epidermal and dermal) of various thicknesses incorporated with gold nanorods (GNRs) concentrations of 10-40 μg/mL by using in-house developed goniometric setup. Results show that 10 μg/mL GNRs in the phantom increase g by ~50% (g = 0.9471) w.r.t. phantom without NPs. Higher concentrations (40 μg/mL) of GNRs decrease g by ~43% (g = 0.5341) w.r.t. phantom with 10 μg/mL GNRs. For 40 μg/mL GNRs phantom, the anisotropy factor reduces by 47% for phantom thickness from 600 to 1800 μm. Anisotropy factor of GNR embedded phantom increased by 44% by using glycerol (10%-40%). Incorporation of NPs in a tumor significantly affects g, a major parameter for light distribution. These measurements provide insights for light scattering based on nanoparticle doses for plasmonic photothermal therapeutics.
Collapse
Affiliation(s)
- Vikas
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
- Biomedical Applications Group, CSIR-Central Scientific Instruments Organisation, Chandigarh, India
| | - Raj Kumar
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
- Micro and Nano Optics Centre, CSIR-Central Scientific Instruments Organisation, Chandigarh, India
| | - Sanjeev Soni
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
- Biomedical Applications Group, CSIR-Central Scientific Instruments Organisation, Chandigarh, India
| |
Collapse
|
4
|
Möckel C, Beck T, Kaliman S, Abuhattum S, Kim K, Kolb J, Wehner D, Zaburdaev V, Guck J. Estimation of the mass density of biological matter from refractive index measurements. BIOPHYSICAL REPORTS 2024; 4:100156. [PMID: 38718671 PMCID: PMC11090064 DOI: 10.1016/j.bpr.2024.100156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 04/04/2024] [Accepted: 04/19/2024] [Indexed: 05/16/2024]
Abstract
The quantification of physical properties of biological matter gives rise to novel ways of understanding functional mechanisms. One of the basic biophysical properties is the mass density (MD). It affects the dynamics in sub-cellular compartments and plays a major role in defining the opto-acoustical properties of cells and tissues. As such, the MD can be connected to the refractive index (RI) via the well known Lorentz-Lorenz relation, which takes into account the polarizability of matter. However, computing the MD based on RI measurements poses a challenge, as it requires detailed knowledge of the biochemical composition of the sample. Here we propose a methodology on how to account for assumptions about the biochemical composition of the sample and respective RI measurements. To this aim, we employ the Biot mixing rule of RIs alongside the assumption of volume additivity to find an approximate relation of MD and RI. We use Monte-Carlo simulations and Gaussian propagation of uncertainty to obtain approximate analytical solutions for the respective uncertainties of MD and RI. We validate this approach by applying it to a set of well-characterized complex mixtures given by bovine milk and intralipid emulsion and employ it to estimate the MD of living zebrafish (Danio rerio) larvae trunk tissue. Our results illustrate the importance of implementing this methodology not only for MD estimations but for many other related biophysical problems, such as mechanical measurements using Brillouin microscopy and transient optical coherence elastography.
Collapse
Affiliation(s)
- Conrad Möckel
- Max Planck Institute for the Science of Light, Erlangen, Germany; Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany; Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Timon Beck
- Max Planck Institute for the Science of Light, Erlangen, Germany; Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
| | - Sara Kaliman
- Max Planck Institute for the Science of Light, Erlangen, Germany; Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
| | - Shada Abuhattum
- Max Planck Institute for the Science of Light, Erlangen, Germany; Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
| | - Kyoohyun Kim
- Max Planck Institute for the Science of Light, Erlangen, Germany; Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
| | - Julia Kolb
- Max Planck Institute for the Science of Light, Erlangen, Germany; Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany; Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Daniel Wehner
- Max Planck Institute for the Science of Light, Erlangen, Germany; Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
| | - Vasily Zaburdaev
- Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany; Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Jochen Guck
- Max Planck Institute for the Science of Light, Erlangen, Germany; Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany; Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
| |
Collapse
|
5
|
Zotov AK, Pushkarev AV, Alekseeva AI, Zaytsev KI, Ryabikin SS, Tsiganov DI, Zhidkov DA, Burkov IA, Kurlov VN, Dolganova IN. Optical Sensing of Tissue Freezing Depth by Sapphire Cryo-Applicator and Steady-State Diffuse Reflectance Analysis. SENSORS (BASEL, SWITZERLAND) 2024; 24:3655. [PMID: 38894444 PMCID: PMC11175356 DOI: 10.3390/s24113655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Revised: 05/31/2024] [Accepted: 06/02/2024] [Indexed: 06/21/2024]
Abstract
This work describes a sapphire cryo-applicator with the ability to sense tissue freezing depth during cryosurgery by illumination of tissue and analyzing diffuse optical signals in a steady-state regime. The applicator was manufactured by the crystal growth technique and has several spatially resolved internal channels for accommodating optical fibers. The method of reconstructing freezing depth proposed in this work requires one illumination and two detection channels. The analysis of the detected intensities yields the estimation of the time evolution of the effective attenuation coefficient, which is compared with the theoretically calculated values obtained for a number of combinations of tissue parameters. The experimental test of the proposed applicator and approach for freezing depth reconstruction was performed using gelatin-based tissue phantom and rat liver tissue in vivo. It revealed the ability to estimate depth up to 8 mm. The in vivo study confirmed the feasibility of the applicator to sense the freezing depth of living tissues despite the possible diversity of their optical parameters. The results justify the potential of the described design of a sapphire instrument for cryosurgery.
Collapse
Affiliation(s)
- Arsen K. Zotov
- Osipyan Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka 142432, Russia; (A.K.Z.)
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow 119991, Russia
| | - Aleksandr V. Pushkarev
- Bauman Moscow State Technical University, Moscow 105005, Russia
- Federal State Budgetary Educational Institution of Further Professional Education “Russian Medical Academy of Continuous Professional Education”, Ministry of Healthcare of the Russian Federation, Moscow 125993, Russia
| | - Anna I. Alekseeva
- Avtsyn Research Institute of Human Morphology, FSBSI “Petrovsky National Research Centre of Surgery”, Moscow 117418, Russia
| | - Kirill I. Zaytsev
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow 119991, Russia
| | - Sergey S. Ryabikin
- Bauman Moscow State Technical University, Moscow 105005, Russia
- Federal State Budgetary Educational Institution of Further Professional Education “Russian Medical Academy of Continuous Professional Education”, Ministry of Healthcare of the Russian Federation, Moscow 125993, Russia
| | - Dmitry I. Tsiganov
- Bauman Moscow State Technical University, Moscow 105005, Russia
- Federal State Budgetary Educational Institution of Further Professional Education “Russian Medical Academy of Continuous Professional Education”, Ministry of Healthcare of the Russian Federation, Moscow 125993, Russia
| | - Dmitriy A. Zhidkov
- Bauman Moscow State Technical University, Moscow 105005, Russia
- Federal State Budgetary Educational Institution of Further Professional Education “Russian Medical Academy of Continuous Professional Education”, Ministry of Healthcare of the Russian Federation, Moscow 125993, Russia
| | - Ivan A. Burkov
- Bauman Moscow State Technical University, Moscow 105005, Russia
| | - Vladimir N. Kurlov
- Osipyan Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka 142432, Russia; (A.K.Z.)
| | - Irina N. Dolganova
- Osipyan Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka 142432, Russia; (A.K.Z.)
| |
Collapse
|
6
|
Aumiller M, Arazar A, Sroka R, Dietrich O, Rühm A. Investigations on correlations between changes of optical tissue properties and NMR relaxation times. Photodiagnosis Photodyn Ther 2024; 45:103968. [PMID: 38215958 DOI: 10.1016/j.pdpdt.2024.103968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 01/03/2024] [Accepted: 01/09/2024] [Indexed: 01/14/2024]
Abstract
BACKGROUND Accurate light dosimetry is a complex remaining challenge in interstitial photodynamic therapy (iPDT) for malignant gliomas. The light dosimetry should ideally be based on the tissue morphology and the individual optical tissue properties of each tissue type in the target region. First investigations are reported on using NMR information to estimate changes of individual optical tissue properties. METHODS Porcine brain tissue and optical tissue phantoms were investigated. To the porcine brain, supplements were added to simulate an edema or high blood content. The tissue phantoms were based on agar, Lipoveneous, ink, blood and gadobutrol (Gd-based MRI contrast agent). The concentrations of phantom ingredients and tissue additives are varied to compare concentration-dependent effects on optical and NMR properties. A 3-tesla whole-body MRI system was used to determine T1 and T2 relaxation times. Optical tissue properties, i.e., the spectrally resolved absorption and reduced scattering coefficient, were obtained using a single integrating sphere setup. The observed changes of NMR and optical properties were compared to each other. RESULTS By adjusting the NMR relaxation times and optical tissue properties of the tissue phantoms to literature values, recipes for human brain tumor, white matter and grey matter tissue phantoms were obtained that mimic these brain tissues simultaneously in both properties. For porcine brain tissue, it was observed that with increasing water concentration in the tissue, both NMR-relaxation times increased, while µa decreased and µs' increased at 635 nm. The addition of blood to porcine brain samples showed a constant T1, while T2 shortened and the absorption coefficient at 635 nm increased. CONCLUSIONS In this investigation, by changing sample contents, notable changes of both NMR relaxation times and optical tissue properties have been observed and their relations examined. The developed dual NMR/optical tissue phantoms can be used in iPDT research, clinical training and demonstrations.
Collapse
Affiliation(s)
- Maximilian Aumiller
- Laser-Forschungslabor, LIFE Center, LMU University Hospital, LMU Munich, Planegg 82152, Germany; Department of Urology, LMU University Hospital, LMU Munich, Munich 81377, Germany.
| | - Asmerom Arazar
- Laser-Forschungslabor, LIFE Center, LMU University Hospital, LMU Munich, Planegg 82152, Germany
| | - Ronald Sroka
- Laser-Forschungslabor, LIFE Center, LMU University Hospital, LMU Munich, Planegg 82152, Germany; Department of Urology, LMU University Hospital, LMU Munich, Munich 81377, Germany
| | - Olaf Dietrich
- Department of Radiology, LMU University Hospital, LMU Munich, Munich 81377, Germany
| | - Adrian Rühm
- Laser-Forschungslabor, LIFE Center, LMU University Hospital, LMU Munich, Planegg 82152, Germany; Department of Urology, LMU University Hospital, LMU Munich, Munich 81377, Germany
| |
Collapse
|
7
|
Gautam R, Mac Mahon D, Eager G, Ma H, Guadagno CN, Andersson-Engels S, Konugolu Venkata Sekar S. Fabrication and characterization of multi-biomarker optimized tissue-mimicking phantoms for multi-modal optical spectroscopy. Analyst 2023; 148:4768-4776. [PMID: 37665320 DOI: 10.1039/d3an00680h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/05/2023]
Abstract
Rapid advancement of novel optical spectroscopy and imaging systems relies on the availability of well-characterised and reproducible protocols for phantoms as a standard for the validation of the technique. The tissue-mimicking phantoms are also used to investigate photon transport in biological samples before clinical trials that require well-characterized phantoms with known optical properties (reduced scattering (μ's) and absorption (μa) coefficients). However, at present, there is limited literature available providing well-characterized phantom recipes considering various biomarkers and tested over a wide range of optical properties covering most of the human organs and applicable to multimodal optical spectroscopy. In this study, gelatin-based phantoms were designed to simulate tissue optical properties where India ink and Intralipid were used as absorbing and scattering agents, respectively. Multiple biomarkers were simulated by varying the gelatin concentration to mimic the change in tissue hydration and hydroxyapatite concentration to mimic bone signature. The recipe along with biomarkers were optimized and characterised over a wide range of optical properties (μa from 0.1 to 0.5 cm-1; μ's from 5 to 15 cm-1) relevant to human tissue using a broadband time-domain diffuse optical spectrometer. The data collected showed a linear relationship between the concentration of ink/lipids and μa/μ's values with negligible coupling between μa and μ's values. While being stored in a refrigerator post-fabrication, the μa and μ's did not change significantly (<4% coefficient of variation, 'CV') over three weeks. The reproducibility in three different sets was validated experimentally and found to be strong with a variation of ≤6% CV in μa and ≤9% CV in μ's. From the 3 × 3 data of μa and μ's matrices, one can deduce the recipe for any target absorption or reduced scattering coefficient. The applicability of the phantoms was tested using diffuse reflectance and Raman spectrometers. A use case application was demonstrated for Raman spectroscopy where hydration and hydroxyapatite phantoms were designed to characterize the Raman instrument. The Raman instrument could detect the change in 1% of HA and 5% of hydration. This study presents a first-of-its-kind robust, well-characterized, multi-biomarker phantom recipe for calibration and benchmarking of multimodal spectroscopy devices assisting in their clinical translation.
Collapse
Affiliation(s)
- Rekha Gautam
- Biophotonics@Tyndall, IPIC, Tyndall National Institute, T12 R5CP Cork, Ireland.
| | | | - Gráinne Eager
- School of Physics, Trinity College Dublin, Dublin 2, Ireland
| | - Hui Ma
- Biophotonics@Tyndall, IPIC, Tyndall National Institute, T12 R5CP Cork, Ireland.
| | | | - Stefan Andersson-Engels
- Biophotonics@Tyndall, IPIC, Tyndall National Institute, T12 R5CP Cork, Ireland.
- Department of Physics, University College Cork, T12 K8AF Cork, Ireland
| | | |
Collapse
|
8
|
Wu Z, Deng B, Zhou Y, Xie H, Zhang Y, Lin L, Ye J. Non-Invasive Detection, Precise Localization, and Perioperative Navigation of In Vivo Deep Lesions Using Transmission Raman Spectroscopy. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2301721. [PMID: 37340601 PMCID: PMC10460859 DOI: 10.1002/advs.202301721] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 05/20/2023] [Indexed: 06/22/2023]
Abstract
Non-invasive detection and precise localization of deep lesions have attracted significant attention for both fundamental and clinical studies. Optical modality techniques are promising with high sensitivity and molecular specificity, but are limited by shallow tissue penetration and the failure to accurately determine lesion depth. Here the authors report in vivo ratiometric surface-enhanced transmission Raman spectroscopy (SETRS) for non-invasive localization and perioperative surgery navigation of deep sentinel lymph nodes in live rats. The SETRS system uses ultrabright surface-enhanced Raman spectroscopy (SERS) nanoparticles with a low detection limit of 10 pM and a home-built photosafe transmission Raman spectroscopy setup. The ratiometric SETRS strategy is proposed based on the ratio of multiple Raman spectral peaks for obtaining lesion depth. Via this strategy, the depth of the phantom lesions in ex vivo rat tissues is precisely determined with a mean-absolute-percentage-error of 11.8%, and the accurate localization of a 6-mm-deep rat popliteal lymph node is achieved. The feasibility of ratiometric SETRS allows the successful perioperative navigation of in vivo lymph node biopsy surgery in live rats under clinically safe laser irradiance. This study represents a significant step toward the clinical translation of TRS techniques, providing new insights for the design and implementation of in vivo SERS applications.
Collapse
Affiliation(s)
- Zongyu Wu
- State Key Laboratory of Systems Medicine for Cancer, School of biomedical engineeringShanghai Jiao Tong UniversityShanghai200030P. R. China
| | - Binge Deng
- State Key Laboratory of Systems Medicine for Cancer, School of biomedical engineeringShanghai Jiao Tong UniversityShanghai200030P. R. China
| | - Yutong Zhou
- State Key Laboratory of Systems Medicine for Cancer, School of biomedical engineeringShanghai Jiao Tong UniversityShanghai200030P. R. China
| | - Haoqiang Xie
- State Key Laboratory of Systems Medicine for Cancer, School of biomedical engineeringShanghai Jiao Tong UniversityShanghai200030P. R. China
| | - Yumin Zhang
- State Key Laboratory of Systems Medicine for Cancer, School of biomedical engineeringShanghai Jiao Tong UniversityShanghai200030P. R. China
| | - Li Lin
- State Key Laboratory of Systems Medicine for Cancer, School of biomedical engineeringShanghai Jiao Tong UniversityShanghai200030P. R. China
| | - Jian Ye
- State Key Laboratory of Systems Medicine for Cancer, School of biomedical engineeringShanghai Jiao Tong UniversityShanghai200030P. R. China
- Institute of Medical RoboticsShanghai Jiao Tong UniversityShanghai200240P. R. China
- Shanghai Key Laboratory of Gynecologic Oncology, Ren Ji Hospital, School of MedicineShanghai Jiao Tong UniversityShanghai200127P. R. China
| |
Collapse
|
9
|
Luo J, Wu D, Liu Y, Li Z, Shen Y. Single-exposure ultrasound-modulated optical tomography with a quaternary phase encoded mask. OPTICS LETTERS 2023; 48:2857-2860. [PMID: 37262228 DOI: 10.1364/ol.483921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 04/18/2023] [Indexed: 06/03/2023]
Abstract
Ultrasound-modulated optical tomography (UOT) is a deep-tissue imaging modality that provides optical contrast with acoustic resolution. Among existing implementations, camera-based UOT improves modulation depth through parallel detection but suffers from a low camera frame rate. The condition prohibits this technique from being applied to in vivo applications where speckles decorrelate on a time scale of 1 ms or less. To overcome this challenge, we developed single-exposure camera-based UOT by employing a quaternary phase encoded mask (QPEM). As a proof of concept, we demonstrated imaging of an absorptive target buried inside a dynamic scattering medium with a speckle correlation time as short as 0.49 ms, typical of living biological tissues. Benefiting from the QPEM-enabled single-exposure wavefront measurement (5.5 ms) and GPU-assisted wavefront reconstruction (0.97 ms), the point scanning and result update speed can reach up to 150 Hz. We envision that the QPEM-enabled single-exposure scheme paves the way for in vivo UOT imaging, which holds promise for a variety of medical and biological applications.
Collapse
|
10
|
Dolganova IN, Zotov AK, Safonova LP, Aleksandrova PV, Reshetov IV, Zaytsev KI, Tuchin VV, Kurlov VN. Feasibility test of a sapphire cryoprobe with optical monitoring of tissue freezing. JOURNAL OF BIOPHOTONICS 2023; 16:e202200288. [PMID: 36510652 DOI: 10.1002/jbio.202200288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 11/22/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
This article describes a sapphire cryoprobe as a promising solution to the significant problem of modern cryosurgery that is the monitoring of tissue freezing. This probe consists of a sapphire rod manufactured by the edge-defined film-fed growth technique from Al2 O3 melt and optical fibers accommodated inside the rod and connected to the source and the detector. The probe's design enables detection of spatially resolved diffuse reflected intensities of tissue optical response, which are used for the estimation of tissue freezing depth. The current type of the 12.5-mm diameter sapphire probe cooled down by the liquid nitrogen assumes a superficial cryoablation. The experimental test made by using a gelatin-intralipid tissue phantom shows the feasibility of such concept, revealing the capabilities of monitoring the freezing depth up to 10 mm by the particular instrumentation realization of the probe. This justifies a potential of sapphire-based instruments aided by optical diagnosis in modern cryosurgery.
Collapse
Affiliation(s)
- Irina N Dolganova
- Osipyan Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia
| | - Arsen K Zotov
- Osipyan Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia
| | | | - Polina V Aleksandrova
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | - Igor V Reshetov
- Institute for Cluster Oncology, Sechenov University, Moscow, Russia
| | - Kirill I Zaytsev
- Prokhorov General Physics Institute of the Russian Academy of Sciences, Moscow, Russia
| | - Valery V Tuchin
- Science Medical Center, Saratov State University, Saratov, Russia
- Institute of Precision Mechanics and Control, FRC "Saratov Scientific Centre of the Russian Academy of Sciences", Saratov, Russia
- Tomsk State University, Tomsk, Russia
| | - Vladimir N Kurlov
- Osipyan Institute of Solid State Physics of the Russian Academy of Sciences, Chernogolovka, Russia
| |
Collapse
|
11
|
Kumar R, Soni S. Dynamic change in optical properties of a nanoparticle embedded tumor phantom for plasmonic photothermal cancer therapeutics. JOURNAL OF BIOPHOTONICS 2023; 16:e202200179. [PMID: 36151893 DOI: 10.1002/jbio.202200179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 08/27/2022] [Accepted: 09/15/2022] [Indexed: 06/16/2023]
Abstract
In this study, the temporal dynamic changes in optical properties of gold nanorods (GNR) embedded tumor phantom, during photothermal interaction, are reported for plasmonic photothermal therapeutics. Tumor mimicking bilayer phantoms were prepared by using 1% agarose incorporated with 0.1% coffee powder, 0.3% intralipid solution as epidermis layer; 3% intralipid solution and 0.3% human hemoglobin (Hb) powder as dermis layer. On incorporating GNRs of concentrations 10, 20, and 40 μg/ml within the phantom, the absorption coefficients increases 4-8 times, while there is minimal change in the reduced scattering coefficients. Further the absorption coefficient increased by ~8% with the incorporation of GNRs of concentration 40 μg/ml, while no considerable dynamic change in the optical properties is observed for the phantom embedded with GNRs of concentrations 10, and 20 μg/ml. The discussed results are useful for the selection of GNRs dose for pre-treatment planning of plasmonic photothermal cancer therapeutics.
Collapse
Affiliation(s)
- Raj Kumar
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India
- Micro and Nano Optics Centre, CSIR-Central Scientific Instruments Organisation, Sector-30C, Chandigarh, India
| | - Sanjeev Soni
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India
- Biomedical Applications Group, CSIR-Central Scientific Instruments Organisation, Sector-30C, Chandigarh, India
| |
Collapse
|
12
|
Walter AB, Jansen ED. Development of a platform for broadband, spectra-fitted, tissue optical phantoms. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:025001. [PMID: 36814953 PMCID: PMC9940728 DOI: 10.1117/1.jbo.28.2.025001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
SIGNIFICANCE Current methods of producing optical phantoms are incapable of accurately capturing the wavelength-dependent properties of tissue critical for many optical modalities. AIM We aim to introduce a method of producing solid, inorganic phantoms whose wavelength-dependent optical properties can be matched to those of tissue over the wavelength range of 370 to 950 nm. APPROACH The concentration-dependent optical properties of 20 pigments were characterized and used to determine combinations that result in optimal fits compared to the target properties over the full spectrum. Phantoms matching the optical properties of muscle and nerve, the diffuse reflectance of pale and melanistic skin, and the chromophore concentrations of a computational skin model with varying oxygen saturation ( StO 2 ) were made with this method. RESULTS Both optical property phantoms were found to accurately mimic their respective tissues' absorption and scattering properties across the entire spectrum. The diffuse reflectance phantoms were able to closely approximate skin reflectance regardless of skin type. All three computational skin phantoms were found to have emulated chromophore concentrations close to the model, with an average percent error for the StO 2 of 4.31%. CONCLUSIONS This multipigment phantom platform represents a powerful tool for creating spectrally accurate tissue phantoms, which should increase the availability of standards for many optical techniques.
Collapse
Affiliation(s)
- Alec B. Walter
- Vanderbilt University, Department of Biomedical Engineering, Nashville, Tennessee, United States
- Vanderbilt University, Biophotonics Center, Nashville, Tennessee, United States
| | - E. Duco Jansen
- Vanderbilt University, Department of Biomedical Engineering, Nashville, Tennessee, United States
- Vanderbilt University, Biophotonics Center, Nashville, Tennessee, United States
- Vanderbilt University Medical Center, Department of Neurosurgery, Nashville, Tennessee, United States
| |
Collapse
|
13
|
Lin G, Wu D, Luo J, Liang H, Wei Z, Xu Y, Liu S, Shao L, Shen Y. Coaxial interferometry for camera-based ultrasound-modulated optical tomography with paired illumination. OPTICS EXPRESS 2022; 30:46227-46235. [PMID: 36558581 DOI: 10.1364/oe.470956] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 11/15/2022] [Indexed: 06/17/2023]
Abstract
Ultrasound-modulated optical tomography (UOT), which combines the advantages of both light and ultrasound, is a promising imaging modality for deep-tissue high-resolution imaging. Among existing implementations, camera-based UOT gains huge advances in modulation depth through parallel detection. However, limited by the long exposure time and the slow framerate of modern cameras, the measurement of UOT signals always requires holographic methods with additional reference beams. This requirement increases system complexity and is susceptible to environmental disturbances. To overcome this challenge, we develop coaxial interferometry for camera-based UOT in this work. Such a coaxial scheme is enabled by employing paired illumination with slightly different optical frequencies. To measure the UOT signal, the conventional phase-stepping method in holography can be directly transplanted into coaxial interferometry. Specifically, we performed both numerical investigations and experimental validations for camera-based UOT under the proposed coaxial scheme. One-dimensional imaging for an absorptive target buried inside a scattering medium was demonstrated. With coaxial interferometry, this work presents an effective way to reduce system complexity and cope with environmental disturbances for camera-based UOT.
Collapse
|
14
|
Zhou Q, Nozdriukhin D, Chen Z, Glandorf L, Hofmann UAT, Reiss M, Tang L, Deán‐Ben XL, Razansky D. Depth-Resolved Localization Microangiography in the NIR-II Window. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 10:e2204782. [PMID: 36403231 PMCID: PMC9811471 DOI: 10.1002/advs.202204782] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 10/17/2022] [Indexed: 06/16/2023]
Abstract
Detailed characterization of microvascular alterations requires high-resolution 3D imaging methods capable of providing both morphological and functional information. Existing optical microscopy tools are routinely used for microangiography, yet offer suboptimal trade-offs between the achievable field of view and spatial resolution with the intense light scattering in biological tissues further limiting the achievable penetration depth. Herein, a new approach for volumetric deep-tissue microangiography based on stereovision combined with super-resolution localization imaging is introduced that overcomes the spatial resolution limits imposed by light diffusion and optical diffraction in wide-field imaging configurations. The method capitalizes on localization and tracking of flowing fluorescent particles in the second near-infrared window (NIR-II, ≈1000-1700 nm), with the third (depth) dimension added by triangulation and stereo-matching of images acquired with two short-wave infrared cameras operating in a dual-view mode. The 3D imaging capability enabled with the proposed method facilitates a detailed visualization of microvascular networks and an accurate blood flow quantification. Experiments performed in tissue-mimicking phantoms demonstrate that high resolution is preserved up to a depth of 4 mm in a turbid medium. Transcranial microangiography of the entire murine cortex and penetrating vessels is further demonstrated at capillary level resolution.
Collapse
Affiliation(s)
- Quanyu Zhou
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Daniil Nozdriukhin
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Zhenyue Chen
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Lukas Glandorf
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Urs A. T. Hofmann
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Michael Reiss
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Lin Tang
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Xosé Luís Deán‐Ben
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| | - Daniel Razansky
- Institute of Pharmacology and Toxicology and Institute for Biomedical EngineeringFaculty of MedicineUniversity of ZurichZurich8057Switzerland
- Institute for Biomedical EngineeringDepartment of Information Technology and Electrical EngineeringETH ZurichZurich8093Switzerland
| |
Collapse
|
15
|
Feng L, Cai S, Zhang J, Lou K, Yang Z, Qu J, Wen W. NIR-II multifocal structured illumination microscopy. OPTICS LETTERS 2022; 47:4656-4659. [PMID: 36107056 DOI: 10.1364/ol.469259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 08/23/2022] [Indexed: 06/15/2023]
Abstract
Optical microscopy has been widely used as a versatile tool in biological research. However, its penetration depth and spatial resolution are desperately limited by light scattering during deep propagation in turbid medium. Here, we implement near-infrared second window (1000-1700 nm) multifocal structured illumination microscopy (NIR-II MSIM) capable of deep penetration, high contrast, and enhanced spatial resolution. Raster-scanning multifocal illumination patterns ensure homogeneous illumination of the sample. By integrating NIR-II photoemission into multifocal photoexcitation, NIR-II MSIM affords deep imaging with improved lateral resolution (∼1.49 µm) at a depth of 2.5 mm in an Intralipid/agar phantom and outstanding contrast. Additionally, imaging at longer wavelength in the NIR-II region shows superior performance. This NIR-II MSIM system will afford a promising platform for studying physiological phenomena in turbid specimens in the future.
Collapse
|
16
|
Feng X, Li GY, Ramier A, Eltony AM, Yun SH. In vivo stiffness measurement of epidermis, dermis, and hypodermis using broadband Rayleigh-wave optical coherence elastography. Acta Biomater 2022; 146:295-305. [PMID: 35470076 DOI: 10.1016/j.actbio.2022.04.030] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 04/14/2022] [Accepted: 04/19/2022] [Indexed: 11/01/2022]
Abstract
Traveling-wave optical coherence elastography (OCE) is a promising technique to measure the stiffness of biological tissues. While OCE has been applied to relatively homogeneous samples, tissues with significantly varying elasticity through depth pose a challenge, requiring depth-resolved measurement with sufficient resolution and accuracy. Here, we develop a broadband Rayleigh-wave OCE technique capable of measuring the elastic moduli of the 3 major skin layers (epidermis, dermis, and hypodermis) reliably by analyzing the dispersion of leaky Rayleigh surface waves over a wide frequency range of 0.1-10 kHz. We show that a previously unexplored, high frequency range of 4-10 kHz is critical to resolve the thin epidermis, while a low frequency range of 0.2-1 kHz is adequate to probe the dermis and deeper hypodermis. We develop a dual bilayer-based inverse model to determine the elastic moduli in all 3 layers and verify its high accuracy with finite element analysis and skin-mimicking phantoms. Finally, the technique is applied to measure the forearm skin of healthy volunteers. The Young's modulus of the epidermis (including the stratum corneum) is measured to be ∼ 4 MPa at 4-10 kHz, whereas Young's moduli of the dermis and hypodermis are about 40 and 15 kPa, respectively, at 0.2-1 kHz. Besides dermatologic applications, this method may be useful for the mechanical analysis of various other layered tissues with sub-mm depth resolution. STATEMENT OF SIGNIFICANCE: To our knowledge, this is the first study that resolves the stiffness of the thin epidermis from the dermis and hypodermis, made possible by using high-frequency (4 - 10 kHz) elastic waves and optical coherence elastography. Beyond the skin, this technique may be useful for mechanical characterizations of various layered biomaterials and tissues.
Collapse
|
17
|
Hao Y, Ji A, Xing R, Zhu W, Jiang B, Jian Y, Chen H. Capillaries segmentation of NIR-II images and its application in ischemic stroke. Comput Biol Med 2022; 147:105742. [PMID: 35759993 DOI: 10.1016/j.compbiomed.2022.105742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 06/05/2022] [Accepted: 06/11/2022] [Indexed: 11/03/2022]
Abstract
Fluorescence imaging in the second near-infrared window (NIR-II) offers μm resolution blood vessel information noninvasively, which is crucial for the diagnosis and surgery treatment of some blood vessel-related diseases. However, only a few blood vessel segmentation algorithms have been done for the NIR-II images so far. Here, we proposed a vessel segmentation algorithm that used multi-scale enhancement and fractional differential to enhance capillaries, and then segmented vessels based on the blood vessels' tubular characteristics. Experimental results showed that this method could effectively suppress the point and lump tissue noise influence during vascular segmentation. The accuracy of vessel identification by other algorithms dropped below 30%, while our algorithm still achieved an accuracy of around 50% in deep vessel segmentation experiments with the 6.5 mm Intralipid. So it had the advantage of accurately detecting deep and dim blood capillaries. Meanwhile, the vascular density quantization algorithm had been successfully applied to the mice's ischemic stroke evaluations for the first time. In addition, this algorithm can provide the quantified vessel features under physiological or pathological conditions, which could be used to accurately evaluate the stroke drugs' therapeutic effect in the future.
Collapse
Affiliation(s)
- Yifan Hao
- Shanghai Institute of Technical Physics of the Chinese Academy of Sciences, Shanghai, 200083, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Aiyan Ji
- Molecular Imaging Center, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai, 201203, China.
| | - Rongrong Xing
- Shanghai Research Center for Modernization of Traditional Chinese Medicine, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai, 201203, China.
| | - Wenqing Zhu
- Shanghai Institute of Technical Physics of the Chinese Academy of Sciences, Shanghai, 200083, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Baohong Jiang
- Shanghai Research Center for Modernization of Traditional Chinese Medicine, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai, 201203, China.
| | - Yi Jian
- Shanghai Institute of Technical Physics of the Chinese Academy of Sciences, Shanghai, 200083, China.
| | - Hao Chen
- Molecular Imaging Center, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai, 201203, China.
| |
Collapse
|
18
|
Muhammad M, Prakash J, Liapis E, Ntziachristos V, Jüstel D. Weighted model-based optoacoustic reconstruction for partial-view geometries. JOURNAL OF BIOPHOTONICS 2022; 15:e202100334. [PMID: 35133073 DOI: 10.1002/jbio.202100334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/22/2022] [Accepted: 02/07/2022] [Indexed: 06/14/2023]
Abstract
Acoustic heterogeneities in biological samples are known to cause artifacts in tomographic optoacoustic (photoacoustic) image reconstruction. A statistical weighted model-based reconstruction approach was previously introduced to mitigate such artifacts. However, this approach does not reliably provide high-quality reconstructions for partial-view imaging systems, which are common in preclinical and clinical optoacoustics. In this article, the capability of the weighted model-based algorithm is extended to generate optoacoustic reconstructions with less distortions for partial-view geometry data. This is achieved by manipulating the weighting scheme based on the detector geometry. Using partial-view optoacoustic tomography data from a tissue-mimicking phantom containing a strong acoustic reflector, tumors grafted onto mice, and a mouse brain with intact skull, the proposed partial-view-corrected weighted model-based algorithm is shown to mitigate reflection artifacts in reconstructed images without distorting structures or boundaries, compared with both conventional model-based and the weighted model-based algorithms. It is also demonstrated that the partial-view-corrected weighted model-based algorithm has the additional advantage of suppressing streaking artifacts due to the partial-view geometry itself in the presence of a very strong optoacoustic chromophore. Due to its enhanced performance, the partial-view-corrected weighted model-based algorithm may prove useful for improving the quality of partial-view multispectral optoacoustic tomography, leading to enhanced visualization of functional parameters such as tissue oxygenation.
Collapse
Affiliation(s)
- Marwan Muhammad
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Center for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Jaya Prakash
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Center for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Evangelos Liapis
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Center for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
| | - Vasilis Ntziachristos
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Center for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
- Munich Institute of Robotics and Machine Intelligence (MIRMI), Technical University of Munich, Munich, Germany
| | - Dominik Jüstel
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging at the Center for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, Germany
- Institute of Computational Biology, Helmholtz Zentrum München, Neuherberg, Germany
| |
Collapse
|
19
|
Shen Y, Lifante J, Zabala-Gutierrez I, de la Fuente-Fernández M, Granado M, Fernández N, Rubio-Retama J, Jaque D, Marin R, Ximendes E, Benayas A. Reliable and Remote Monitoring of Absolute Temperature during Liver Inflammation via Luminescence-Lifetime-Based Nanothermometry. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2107764. [PMID: 34826883 DOI: 10.1002/adma.202107764] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 11/25/2021] [Indexed: 05/03/2023]
Abstract
Temperature of tissues and organs is one of the first parameters affected by physiological and pathological processes, such as metabolic activity, acute trauma, or infection-induced inflammation. Therefore, the onset and development of these processes can be detected by monitoring deviations from basal temperature. To accomplish this, minimally invasive, reliable, and accurate measurement of the absolute temperature of internal organs is required. Luminescence nanothermometry is the ideal technology for meeting these requirements. Although this technique has lately undergone remarkable developments, its reliability is being questioned due to spectral distortions caused by biological tissues. In this work, how the use of bright Ag2 S nanoparticles featuring temperature-dependent fluorescence lifetime enables reliable and accurate measurement of the absolute temperature of the liver in mice subjected to lipopolysaccharide-induced inflammation is demonstrated. Beyond the remarkable thermal sensitivity (≈ 3% °C-1 around 37 °C) and thermal resolution obtained (smaller than 0.3 °C), the results included in this work set a blueprint for the development of new diagnostic procedures based on the use of intracorporeal temperature as a physiological indicator.
Collapse
Affiliation(s)
- Yingli Shen
- Nanomaterials for Bioimaging Group (NanoBIG), Universidad Autónoma de Madrid, Madrid, 28049, Spain
| | - José Lifante
- Nanomaterials for Bioimaging Group (NanoBIG), Universidad Autónoma de Madrid, Madrid, 28049, Spain
- Nanomaterials for Bioimaging Group (NanoBIG), Instituto Ramón y Cajal de Investigación Sanitaria, Ctra de Colmenar Viejo Km 9,100, Madrid, 28034, Spain
| | - Irene Zabala-Gutierrez
- Departamento de Química en Ciencias Farmacéuticas, Facultad de Farmacia, Universidad Complutense de Madrid, Plaza Ramón y Cajal S/N, Madrid, 28040, Spain
| | | | - Miriam Granado
- Nanomaterials for Bioimaging Group (NanoBIG), Universidad Autónoma de Madrid, Madrid, 28049, Spain
| | - Nuria Fernández
- Nanomaterials for Bioimaging Group (NanoBIG), Universidad Autónoma de Madrid, Madrid, 28049, Spain
- Nanomaterials for Bioimaging Group (NanoBIG), Instituto Ramón y Cajal de Investigación Sanitaria, Ctra de Colmenar Viejo Km 9,100, Madrid, 28034, Spain
| | - Jorge Rubio-Retama
- Departamento de Química en Ciencias Farmacéuticas, Facultad de Farmacia, Universidad Complutense de Madrid, Plaza Ramón y Cajal S/N, Madrid, 28040, Spain
| | - Daniel Jaque
- Nanomaterials for Bioimaging Group (NanoBIG), Universidad Autónoma de Madrid, Madrid, 28049, Spain
- Nanomaterials for Bioimaging Group (NanoBIG), Instituto Ramón y Cajal de Investigación Sanitaria, Ctra de Colmenar Viejo Km 9,100, Madrid, 28034, Spain
| | - Riccardo Marin
- Nanomaterials for Bioimaging Group (NanoBIG), Universidad Autónoma de Madrid, Madrid, 28049, Spain
| | - Erving Ximendes
- Nanomaterials for Bioimaging Group (NanoBIG), Universidad Autónoma de Madrid, Madrid, 28049, Spain
- Nanomaterials for Bioimaging Group (NanoBIG), Instituto Ramón y Cajal de Investigación Sanitaria, Ctra de Colmenar Viejo Km 9,100, Madrid, 28034, Spain
| | - Antonio Benayas
- Nanomaterials for Bioimaging Group (NanoBIG), Universidad Autónoma de Madrid, Madrid, 28049, Spain
- Nanomaterials for Bioimaging Group (NanoBIG), Instituto Ramón y Cajal de Investigación Sanitaria, Ctra de Colmenar Viejo Km 9,100, Madrid, 28034, Spain
| |
Collapse
|
20
|
Jonasson H, Anderson CD, Saager RB. Water and hemoglobin modulated gelatin-based phantoms to spectrally mimic inflamed tissue in the validation of biomedical techniques and the modeling of microdialysis data. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:074712. [PMID: 35106979 PMCID: PMC8804337 DOI: 10.1117/1.jbo.27.7.074712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 01/10/2022] [Indexed: 06/14/2023]
Abstract
SIGNIFICANCE Tissue simulating phantoms are an important part of validating biomedical optical techniques. Tissue pathology in inflammation and oedema involves changes in both water and hemoglobin fractions. AIM We present a method to create solid gelatin-based phantoms mimicking inflammation and oedema with adjustable water and hemoglobin fractions. APPROACH One store-bought gelatin and one research grade gelatin were evaluated. Different water fractions were obtained by varying the water-to-gelatin ratio. Ferrous stabilized human hemoglobin or whole human blood was added as absorbers, and the stability and characteristics of each were compared. Intralipid® was used as the scatterer. All phantoms were characterized using spatial frequency domain spectroscopy. RESULTS The estimated water fraction varied linearly with expected values (R2 = 0.96 for the store-bought gelatin and R2 = 0.99 for the research grade gelatin). Phantoms including ferrous stabilized hemoglobin stayed stable up to one day but had methemoglobin present at day 0. The phantoms with whole blood remained stable up to 3 days using the store-bought gelatin. CONCLUSIONS A range of physiological relevant water fractions was obtained for both gelatin types, with the stability of the phantoms including hemoglobin differing between the gelatin type and hemoglobin preparation. These low-cost phantoms can incorporate other water-based chromophores and be fabricated as thin sheets to form multilayered structures.
Collapse
Affiliation(s)
- Hanna Jonasson
- Linköping University, Department of Biomedical Engineering, Linköping, Sweden
| | - Chris D. Anderson
- Linköping University, Department of Biomedical and Clinical Sciences, Linköping, Sweden
| | - Rolf B. Saager
- Linköping University, Department of Biomedical Engineering, Linköping, Sweden
| |
Collapse
|
21
|
Non-Invasive Blood Flow Speed Measurement Using Optics. SENSORS 2022; 22:s22030897. [PMID: 35161643 PMCID: PMC8838687 DOI: 10.3390/s22030897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/25/2021] [Revised: 01/19/2022] [Accepted: 01/20/2022] [Indexed: 11/17/2022]
Abstract
Non-invasive measurement of the arterial blood speed gives important health information such as cardio output and blood supplies to vital organs. The magnitude and change in arterial blood speed are key indicators of the health conditions and development and progression of diseases. We demonstrated a simple technique to directly measure the blood flow speed in main arteries based on the diffused light model. The concept is demonstrated with a phantom that uses intralipid hydrogel to model the biological tissue and an embedded glass tube with flowing human blood to model the blood vessel. The correlation function of the measured photocurrent was used to find the electrical field correlation function via the Siegert relation. We have shown that the characteristic decorrelation rate (i.e., the inverse of the decoherent time) is linearly proportional to the blood speed and independent of the tube diameter. This striking property can be explained by an approximate analytic solution for the diffused light equation in the regime where the convective flow is the dominating factor for decorrelation. As a result, we have demonstrated a non-invasive method of measuring arterial blood speed without any prior knowledge or assumption about the geometric or mechanic properties of the blood vessels.
Collapse
|
22
|
Jelly ET, Zhao Y, Chu KK, Price H, Crose M, Steelman ZA, Wax A. Deep imaging with 1.3 µm dual-axis optical coherence tomography and an enhanced depth of focus. BIOMEDICAL OPTICS EXPRESS 2021; 12:7689-7702. [PMID: 35003860 PMCID: PMC8713684 DOI: 10.1364/boe.438621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 10/01/2021] [Accepted: 11/03/2021] [Indexed: 06/14/2023]
Abstract
For many clinical applications, such as dermatology, optical coherence tomography (OCT) suffers from limited penetration depth due primarily to the highly scattering nature of biological tissues. Here, we present a novel implementation of dual-axis optical coherence tomography (DA-OCT) that offers improved depth penetration in skin imaging at 1.3 µm compared to conventional OCT. Several unique aspects of DA-OCT are examined here, including the requirements for scattering properties to realize the improvement and the limited depth of focus (DOF) inherent to the technique. To overcome this limitation, our approach uses a tunable lens to coordinate focal plane selection with image acquisition to create an enhanced DOF for DA-OCT. This improvement in penetration depth is quantified experimentally against conventional on-axis OCT using tissue phantoms and mouse skin. The results presented here suggest the potential use of DA-OCT in situations where a high degree of scattering limits depth penetration in OCT imaging.
Collapse
Affiliation(s)
- Evan T. Jelly
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Yang Zhao
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Kengyeh K. Chu
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Hillel Price
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | | | - Zachary A. Steelman
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Adam Wax
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| |
Collapse
|
23
|
Assessment of Skin Deep Layer Biochemical Profile Using Spatially Offset Raman Spectroscopy. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11209498] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Skin cancer is currently the most common type of cancer with millions of cases diagnosed worldwide yearly. The current gold standard for clinical diagnosis of skin cancer is an invasive and relatively time-consuming procedure, consisting of visual examination followed by biopsy collection and histopathological analysis. Raman spectroscopy has been shown to efficiently aid the non-invasive diagnosis of skin cancer when probing the surface of the skin. In this study, we employ a recent development of Raman spectroscopy (Spatially Offset Raman Spectroscopy, SORS) which is able to look deeper in tissue and create a deep layer biochemical profile of the skin in areas where cancer lesions subtly evolve. After optimizing the measurement parameters on skin tissue phantoms, we then adopted SORS on human skin tissue from different anatomical areas to investigate the contribution of the different skin layers to the recorded Raman signal. Our results show that using a diffuse beam with zero offset to probe a sampling volume where the lesion is typically included (surface to epidermis-dermis junction), provides the optimum signal-to-noise ratio (SNR) and may be employed in future skin cancer screening applications.
Collapse
|
24
|
Khurana D, Shaw AK, Soni S. Polydopamine coated gold nano blackbodies for tumor-selective spatial thermal damage during plasmonic photothermal cancer therapy. IEEE Trans Nanobioscience 2021; 21:482-489. [PMID: 34623274 DOI: 10.1109/tnb.2021.3118895] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Plasmonic photothermal therapy (PPTT), which involves nanoparticles and near-infrared radiation (NIR) to generate confined heat, is a potential technique for selective thermal damage of cancerous tissue. Herein, tumor-selective spatial damage characteristics during polydopamine (PDA) coated gold nano blackbodies (AuNBs) mediated PPTT is investigated through a tumortissue mimicking phantom. The spatial temperatures during PPTT were measured within the phantom mimicking the optical scattering of superficial invasive ductal carcinoma (injected with AuNBs) surrounded by a region without AuNBs. The phantom was irradiated using broadband NIR radiation (754-816 nm), and spatial temperatures were measured using thermocouples and an infrared thermal camera. The obtained results demonstrate that the tumor region's temperature was elevated to >50°C in about 2.5 minutes and was maintained thereafter for about 6 minutes, which is well sufficient for the thermal ablation of the tumor. While for the region surrounding the tumor, a temperature of about 40-44°C was attained, which is within safe limits for the said exposure duration. Overall, this study demonstrates that for the considered experimental parameters and tumor dimensions, heat-based thermal damage could be confined to the nanoparticle embedded tumor region while maintaining the safe temperature levels for the surrounding region, i.e., 2 mm beyond the tumor boundary.
Collapse
|
25
|
Zhang R, Du J, He Y, Yuan D, Luo J, Wu D, Ye B, Luo ZC, Shen Y. Characterization of the spectral memory effect of scattering media. OPTICS EXPRESS 2021; 29:26944-26954. [PMID: 34615118 DOI: 10.1364/oe.434331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Accepted: 07/27/2021] [Indexed: 06/13/2023]
Abstract
The optical memory effect is an interesting phenomenon exploited for deep-tissue optical imaging. Besides the widely studied memory effects in the spatial domain to accelerate point scanning speed, the spectral memory effect is also important in multispectral wavefront shaping. Although being theoretically analyzed for decades, quantitative studies of spectral memory effect on a variety of scattering media including biological tissue were rarely reported. In practice, quantifying the range of the spectral memory effect is essential in efficiently shaping broadband light, as it determines the optimum spectral resolution in realizing spatiotemporal focus through scattering media. In this work, we analyze the spectral memory effect based on a diffusion model. An explicit analytical expression involves the illumination wavelength, the diffusion constant, and the sample thickness is derived, which is consistent with the one in the literature. We experimentally quantified the range of spectral correlation for two types of biological tissue, tissue-mimicking phantoms with different concentrations, and diffusers. Specifically, for tissue-mimicking phantoms with calibrated scattering parameters, we show that a correction factor of more than 20 should be inserted, indicating that the range of spectral correlation is much larger than one would expect. This finding is particularly beneficial to multispectral wavefront shaping, as stringent requirements on the spectral resolution could be alleviated by at least one order of magnitude.
Collapse
|
26
|
Ni L, Siddiqui J, Udager AM, Jo J, Wei JT, Davenport MS, Carson PL, Fowlkes JB, Wang X, Xu G. Characterizing the aggressiveness of prostate cancer using an all-optical needle photoacoustic sensing probe: feasibility study. BIOMEDICAL OPTICS EXPRESS 2021; 12:4873-4888. [PMID: 34513230 PMCID: PMC8407826 DOI: 10.1364/boe.430085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 06/18/2021] [Accepted: 06/22/2021] [Indexed: 06/13/2023]
Abstract
In our previous studies, we have developed a prototype interstitial needle sensing probe that can acquire broadband A-line photoacoustic (PA) signals encoding both tissue microarchitecture and histochemical information comparable to that accessible by histology. Paving the road toward clinical translation of this technology, we replaced the piezoelectric hydrophone in the needle PA probe with a fiber optic hydrophone that enabled both broader bandwidth and sufficient signal-to-noise ratio (SNR) for PA signal detection. Such an all-optical design also facilitated disposability and significantly reduced the footprint of the needle PA sensing probe. Experiments were performed on well-controlled phantoms and human prostate tissues. The microarchitectures in each sample were quantitatively evaluated by both the nonlinear spectral slope of the PA signal power spectrum and the generalized gamma (GG) parameter a by implementing envelope statistics to the PA signal. In the studies on phantoms containing optically absorbing microspheres with various sizes and concentrations, the nonlinear spectral slope showed a strong correlation of r=-0.80 with the microsphere dimensions, and a relatively weak correlation of r=-0.54 with the microsphere concentrations, while the GG parameter a showed a strong correlation with the microsphere dimensions (r=0.72) and a moderate correlation with the microsphere concentrations (r=0.63). In the studies on human prostate tissues containing progressive cancer stages, both the nonlinear spectral slope and the GG parameter a demonstrated a statistically significant difference between benign and nonaggressive cancer tissues (p<0.01), and between nonaggressive and aggressive cancer tissues (p<0.01). In addition, a multivariate analysis combining the two quantitative measurements demonstrated the boundaries among the different progressive stages of prostate cancer.
Collapse
Affiliation(s)
- Linyu Ni
- Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - Javed Siddiqui
- Department of Pathology, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - Aaron M Udager
- Michigan Center for Translational Pathology, Rogel Cancer Center, Department of Pathology, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - Janggun Jo
- Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - John T Wei
- Department of Urology, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - Matthew S Davenport
- Department of Radiology, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - Paul L Carson
- Department of Radiology, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - J Brian Fowlkes
- Department of Radiology, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - Xueding Wang
- Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
- Department of Radiology, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| | - Guan Xu
- Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
- Department of Ophthalmology and Visual Sciences, Department of Biomedical Engineering, University of Michigan, 500 S. State St., Ann Arbor, MI 48109, USA
| |
Collapse
|
27
|
Yuan D, Luo J, Wu D, Zhang R, Lai P, Li Z, Shen Y. Single-shot ultrasound-modulated optical tomography with enhanced speckle contrast. OPTICS LETTERS 2021; 46:3095-3098. [PMID: 34197389 DOI: 10.1364/ol.425535] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Accepted: 05/28/2021] [Indexed: 06/13/2023]
Abstract
Ultrasound-modulated optical tomography (UOT) images optical contrast deep inside biological tissue. Among existing approaches, camera-based parallel detection is beneficial in modulation depth but is limited to the relatively slow framerate of cameras. This condition prevents such a scheme from achieving maturity to image live animals with sub-millisecond speckle correlation time. In this work, we developed on-axis single-shot UOT by investigating the statistics of speckles, breaking the restriction imposed by the slow camera framerate. As a proof of concept, we experimentally imaged a one-dimensional absorptive object buried inside a moving scattering medium with speckle correlation time down to 0.48 ms. We envision that this single-shot UOT is promising to cope with live animals with fast speckle decorrelation.
Collapse
|
28
|
Sahlstrom T, Pulkkinen A, Leskinen J, Tarvainen T. Computationally Efficient Forward Operator for Photoacoustic Tomography Based on Coordinate Transformations. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2172-2182. [PMID: 33600313 DOI: 10.1109/tuffc.2021.3060175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Photoacoustic tomography (PAT) is an imaging modality that utilizes the photoacoustic effect. In PAT, a photoacoustic image is computed from measured data by modeling ultrasound propagation in the imaged domain and solving an inverse problem utilizing a discrete forward operator. However, in realistic measurement geometries with several ultrasound transducers and relatively large imaging volume, an explicit formation and use of the forward operator can be computationally prohibitively expensive. In this work, we propose a transformation-based approach for efficient modeling of photoacoustic signals and reconstruction of photoacoustic images. In the approach, the forward operator is constructed for a reference ultrasound transducer and expanded into a general measurement geometry using transformations that map the formulated forward operator in local coordinates to the global coordinates of the measurement geometry. The inverse problem is solved using a Bayesian framework. The approach is evaluated with numerical simulations and experimental data. The results show that the proposed approach produces accurate 3-D photoacoustic images with a significantly reduced computational cost both in memory requirements and time. In the studied cases, depending on the computational factors, such as discretization, over the 30-fold reduction in memory consumption was achieved without a reduction in image quality compared to a conventional approach.
Collapse
|
29
|
Fernandes DA, Fernandes DD, Malik A, Gomes GNW, Appak-Baskoy S, Berndl E, Gradinaru CC, Kolios MC. Multifunctional nanoparticles as theranostic agents for therapy and imaging of breast cancer. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY. B, BIOLOGY 2021; 218:112110. [PMID: 33865007 DOI: 10.1016/j.jphotobiol.2020.112110] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 11/13/2020] [Accepted: 12/18/2020] [Indexed: 11/26/2022]
Abstract
Over the last decade, there has been significant developments in nanotechnology, in particular for combined imaging and therapeutic applications (theranostics). The core or shell of nanoemulsions (NEs) can be loaded with various therapeutic agents, including drugs with low solubility for effective treatment, or various imaging agents for specific imaging modalities (e.g., MRI, fluorescence). In this work, perfluorohexane (PFH) NEs were synthesized for theranostic applications and were coupled to silica coated gold nanoparticles (scAuNPs) to increase the generation of PFH bubbles upon laser induced vaporization (i.e., optical droplet vaporization). The localized heat generated from the absorption properties of these nanoparticles (used to provide photoacoustic signals) can also be used to treat cancer without significantly damaging nearby healthy tissues. The theranostic potential of these PFH-NEs for contrast imaging of tumors and as a drug-delivery vehicle for therapeutic purposes were demonstrated for both in vitro and in vivo systems using a combination of photoacoustic, ultrasound and fluorescence imaging modalities. The ability of PFH-NEs to couple with scAuNPs, attach to the membranes of cancer cells and internalize within cancer cells, are encouraging for targeted chemotherapeutic applications for directly inducing cancer cell death via vaporization in clinical settings.
Collapse
Affiliation(s)
- Donald A Fernandes
- Department of Chemistry & Biology, Ryerson University, Toronto, ON M5B 2K3, Canada; Institute for Biomedical Engineering, Science and Technology (iBEST), a partnership between Ryerson University and St. Michael's Hospital, Toronto, ON M5B 1T8, Canada; Keenan Research Centre for Biomedical Science of St. Michael's Hospital, Toronto, ON, M5B 1T8, Canada.
| | - Dennis D Fernandes
- Department of Physics, University of Toronto, Toronto, ON M5S 1A7, Canada; Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, ON L5L 1C6, Canada
| | - Aimen Malik
- Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, ON L5L 1C6, Canada
| | - Gregory-Neal W Gomes
- Department of Physics, University of Toronto, Toronto, ON M5S 1A7, Canada; Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, ON L5L 1C6, Canada
| | - Sila Appak-Baskoy
- Department of Chemistry & Biology, Ryerson University, Toronto, ON M5B 2K3, Canada; Institute for Biomedical Engineering, Science and Technology (iBEST), a partnership between Ryerson University and St. Michael's Hospital, Toronto, ON M5B 1T8, Canada; Keenan Research Centre for Biomedical Science of St. Michael's Hospital, Toronto, ON, M5B 1T8, Canada
| | - Elizabeth Berndl
- Institute for Biomedical Engineering, Science and Technology (iBEST), a partnership between Ryerson University and St. Michael's Hospital, Toronto, ON M5B 1T8, Canada; Keenan Research Centre for Biomedical Science of St. Michael's Hospital, Toronto, ON, M5B 1T8, Canada; Department of Physics, Ryerson University, Toronto, ON M5B 2K3, Canada
| | - Claudiu C Gradinaru
- Department of Physics, University of Toronto, Toronto, ON M5S 1A7, Canada; Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, ON L5L 1C6, Canada.
| | - Michael C Kolios
- Institute for Biomedical Engineering, Science and Technology (iBEST), a partnership between Ryerson University and St. Michael's Hospital, Toronto, ON M5B 1T8, Canada; Keenan Research Centre for Biomedical Science of St. Michael's Hospital, Toronto, ON, M5B 1T8, Canada; Department of Physics, Ryerson University, Toronto, ON M5B 2K3, Canada.
| |
Collapse
|
30
|
Wang D, Zhang H, Vu T, Zhan Y, Malhotra A, Wang P, Chitgupi U, Rai A, Zhang S, Wang L, Huizinga JD, Lovell JF, Xia J. Trans-illumination intestine projection imaging of intestinal motility in mice. Nat Commun 2021; 12:1682. [PMID: 33727562 PMCID: PMC7966380 DOI: 10.1038/s41467-021-21930-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Accepted: 02/18/2021] [Indexed: 02/07/2023] Open
Abstract
Functional intestinal imaging holds importance for the diagnosis and evaluation of treatment of gastrointestinal diseases. Currently, preclinical imaging of intestinal motility in animal models is performed either invasively with excised intestines or noninvasively under anesthesia, and cannot reveal intestinal dynamics in the awake condition. Capitalizing on near-infrared optics and a high-absorbing contrast agent, we report the Trans-illumination Intestine Projection (TIP) imaging system for free-moving mice. After a complete system evaluation, we performed in vivo studies, and obtained peristalsis and segmentation motor patterns of free-moving mice. We show the in vivo typical segmentation motor pattern, that was previously shown in ex vivo studies to be controlled by intestinal pacemaker cells. We also show the effects of anesthesia on motor patterns, highlighting the possibility to study the role of the extrinsic nervous system in controlling motor patterns, which requires unanesthetized live animals. Combining with light-field technologies, we further demonstrated 3D imaging of intestine in vivo (3D-TIP). Importantly, the added depth information allows us to extract intestines located away from the abdominal wall, and to quantify intestinal motor patterns along different directions. The TIP system should open up avenues for functional imaging of the GI tract in conscious animals in natural physiological states.
Collapse
Affiliation(s)
- Depeng Wang
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - Huijuan Zhang
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
| | - Tri Vu
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
| | - Ye Zhan
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
| | - Akash Malhotra
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Pei Wang
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Upendra Chitgupi
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
| | - Aliza Rai
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Sizhe Zhang
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
| | - Lidai Wang
- Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Jan D Huizinga
- Farncombe Family Digestive Health Research Institute, Department of Medicine, McMaster University, Ontario, Canada
| | - Jonathan F Lovell
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA
| | - Jun Xia
- Department of Biomedical Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA.
| |
Collapse
|
31
|
Multi-Lens Arrays (MLA)-Assisted Photothermal Effects for Enhanced Fractional Cancer Treatment: Computational and Experimental Validations. Cancers (Basel) 2021; 13:cancers13051146. [PMID: 33800182 PMCID: PMC7962441 DOI: 10.3390/cancers13051146] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 03/03/2021] [Accepted: 03/04/2021] [Indexed: 01/05/2023] Open
Abstract
Simple Summary Colorectal cancer is one of the most common cancers and the third leading cause of cancer-related deaths in the United States. As a non- or minimally invasive cancer treatment, photothermal therapy (PTT) has been widely used to generate irreversible thermal injuries in tumors. However, conventional PTT employs an end-firing flat fiber to deliver laser energy, leading to the incomplete removal of tumor tissues due to an uneven beam distribution over the tumor surface. Multi-lens arrays (MLA) generate multiple micro-beams to uniformly distribute laser energy on the tissue surface. Therefore, the application of MLA for PTT in cancer affords a spatially enhanced distribution of micro-beams and laser-induced temperature in the tumor. The purpose of the current study is to computationally and experimentally demonstrate the therapeutic benefits of MLA-assisted fractional PTT on colorectal cancer, in comparison to flat fiber-based PTT. Abstract Conventional photothermal therapy (PTT) for cancer typically employs an end-firing flat fiber (Flat) to deliver laser energy, leading to the incomplete treatment of target cells due to a Gaussian-shaped non-uniform beam profile. The purpose of the current study is to evaluate the feasibility of multi-lens arrays (MLA) for enhanced PTT by delivering laser light in a fractional micro-beam pattern. Computational and experimental evaluations compare the photothermal responses of gelatin phantoms and aqueous dye solutions to irradiations with Flat and MLA. In vivo colon cancer models have been developed to validate the therapeutic capacity of MLA-assisted irradiation. MLA yields 1.6-fold wider and 1.9-fold deeper temperature development in the gelatin phantom than Flat, and temperature monitoring identified the optimal treatment condition at an irradiance of 2 W/cm2 for 180 s. In vivo tests showed that the MLA group was accompanied by complete tumor eradication, whereas the Flat group yielded incomplete removal and significant tumor regrowth 14 days after PTT. The proposed MLA-assisted PTT spatially augments photothermal effects with the fractional micro-beams on the tumor and helps achieve complete tumor removal without recurrence. Further investigations are expected to optimize treatment conditions with various wavelengths and photosensitizers to warrant treatment efficacy and safety for clinical translation.
Collapse
|
32
|
Fernandes DA, Appak-Baskoy S, Berndl E, Kolios MC. Laser activatable perfluorocarbon bubbles for imaging and therapy through enhanced absorption from coupled silica coated gold nanoparticles. RSC Adv 2021; 11:4906-4920. [PMID: 35424456 PMCID: PMC8694477 DOI: 10.1039/d0ra08009h] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 11/20/2020] [Indexed: 12/29/2022] Open
Abstract
Nanoparticles have extensively been used for cancer therapy and imaging (i.e., theranostics) using various imaging modalities. Due to their physical and chemical properties (e.g., absorption, fluorescence, and magnetic properties) they have been used for image guided therapy for cancer treatment monitoring. There are various limitations that make many theranostic agents unable to be used for the extended periods of time required for enhancing theranostic capabilities. Some of these are due to inherent characteristics (e.g., change and/or breakdown of structure) present upon continuous irradiation and others are due to environmental (i.e., physiological) conditions that can lead to physical instability (i.e., in terms of size) affecting the amount of particles that can accumulate at the target site and the overall contrast that can be achieved. In this study, perfluorohexane (PFH) nanoemulsions (NEs) were synthesized with silica coated gold nanoparticles (PFH-NEs-scAuNPs) in order to give both stable and enhanced signals for cancer imaging by increasing vaporization of the emulsions into bubbles through the process of optical droplet vaporization (ODV). The resulting perfluorohexane bubbles could be imaged using nonlinear ultrasound (NL US) which significantly increases the signal to noise ratio due to the nonlinear scattering properties of oscillating bubbles. The NL US signals from PFH bubbles were found to be more stable compared to conventional bubbles used for contrast imaging. In addition, the vaporization of PFH NEs into bubbles was shown to cause significant cancer cell death reflecting the theranostic capabilities of the formed PFH bubbles. Since cell death is initiated with laser excitation of PFH-NEs-scAuNPs, these nanoparticles can specifically target cancer cells once they have accumulated at the tumor region. Due to the type of theranostic agent and imaging modality used, the PFH-NEs-scAuNPs can be used to provide higher specificity compared to other agents for locating the tumor region by minimizing tissue specific signals while at the same time being used to treat cancer. PFH-NEs from PFH-NEs-scAuNPs can vaporize upon laser excitation leading to formation of PFH bubbles that can be used for contrast enhanced US imaging and therapy.![]()
Collapse
Affiliation(s)
- Donald A. Fernandes
- Department of Chemistry & Biology
- Ryerson University
- Toronto
- Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), A Partnership Between Ryerson University and St. Michael's Hospital
| | - Sila Appak-Baskoy
- Department of Chemistry & Biology
- Ryerson University
- Toronto
- Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), A Partnership Between Ryerson University and St. Michael's Hospital
| | - Elizabeth Berndl
- Institute for Biomedical Engineering, Science and Technology (iBEST), A Partnership Between Ryerson University and St. Michael's Hospital
- Toronto
- Canada
- Keenan Research Centre for Biomedical Science of St. Michael's Hospital
- Toronto
| | - Michael C. Kolios
- Institute for Biomedical Engineering, Science and Technology (iBEST), A Partnership Between Ryerson University and St. Michael's Hospital
- Toronto
- Canada
- Keenan Research Centre for Biomedical Science of St. Michael's Hospital
- Toronto
| |
Collapse
|
33
|
Chuang YC, Chu CH, Cheng SH, Liao LD, Chu TS, Chen NT, Paldino A, Hsia Y, Chen CT, Lo LW. Annealing-modulated nanoscintillators for nonconventional X-ray activation of comprehensive photodynamic effects in deep cancer theranostics. Theranostics 2020; 10:6758-6773. [PMID: 32550902 PMCID: PMC7295068 DOI: 10.7150/thno.41752] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Accepted: 05/04/2020] [Indexed: 01/10/2023] Open
Abstract
Photodynamic therapy (PDT), which involves the generation of reactive oxygen species (ROS) through interactions of a photosensitizer (PS) with light and oxygen, has been applied in oncology. Over the years, PDT techniques have been developed for the treatment of deep-seated cancers. However, (1) the tissue penetration limitation of excitation photon, (2) suppressed efficiency of PS due to multiple energy transfers, and (3) insufficient oxygen source in hypoxic tumor microenvironment still constitute major challenges facing the clinical application of PDT for achieving effective treatment. We present herein a PS-independent, ionizing radiation-induced PDT agent composed of yttrium oxide nanoscintillators core and silica shell (Y2O3:Eu@SiO2) with an annealing process. Our results revealed that annealed Y2O3:Eu@SiO2 could directly induce comprehensive photodynamic effects under X-ray irradiation without the presence of PS molecules. The crystallinity of Y2O3:Eu@SiO2 was demonstrated to enable the generation of electron-hole (e--h+) pairs in Y2O3 under ionizing irradiation, giving rise to the formation of ROS including superoxide, hydroxyl radical and singlet oxygen. In particular, combining Y2O3:Eu@SiO2 with fractionated radiation therapy increased radio-resistant tumor cell damage. Furthermore, photoacoustic imaging of tumors showed re-distribution of oxygen saturation (SO2) and reoxygenation of the hypoxia region. The results of this study support applicability of the integration of fractionated radiation therapy with Y2O3:Eu@SiO2, achieving synchronously in-depth and oxygen-insensitive X-ray PDT. Furthermore, we demonstrate Y2O3:Eu@SiO2 exhibited radioluminescence (RL) under X-ray irradiation and observed the virtually linear correlation between X-ray-induced radioluminescence (X-RL) and the Y2O3:Eu@SiO2 concentration in vivo. With the pronounced X-RL for in-vivo imaging and dosimetry, it possesses significant potential for utilization as a precision theranostics producing highly efficient X-ray PDT for deep-seated tumors.
Collapse
|
34
|
Yang J, Li L, Li J, Cheng Z, Liu Y, Wang LV. Fighting against fast speckle decorrelation for light focusing inside live tissue by photon frequency shifting. ACS PHOTONICS 2020; 7:837-844. [PMID: 34113691 PMCID: PMC8188831 DOI: 10.1021/acsphotonics.0c00027] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Focusing light inside live tissue by digital optical phase conjugation (DOPC) has been intensively investigated due to its potential biomedical applications in deep-tissue imaging, optogenetics, microsurgery, and phototherapy. However, fast physiological motions in a live animal, such as blood flow and respiratory motions, produce undesired photon perturbation and thus inevitably deteriorate the performance of light focusing. Here, we develop a photon-frequency-shifting DOPC method to fight against fast physiological motions by switching the states of a guide star at a distinctive frequency. Therefore, the photons tagged by the guide star are well detected at the specific frequency, separating them from the photons perturbed by fast motions. Light focusing was demonstrated in both phantoms in vitro and mice in vivo with substantially improved focusing contrast. This work puts a new perspective on light focusing inside live tissue and promises wide biomedical applications.
Collapse
Affiliation(s)
- Jiamiao Yang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California 91125, USA
| | - Lei Li
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California 91125, USA
| | - Jingwei Li
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California 91125, USA
- Present address: Centre for Optical and Electromagnetic Research, Chinese National Engineering Research Center for Optical Instruments, Zhejiang University, Hangzhou 310058, China
| | - Zhongtao Cheng
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California 91125, USA
| | - Yan Liu
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California 91125, USA
| | - Lihong V. Wang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California 91125, USA
| |
Collapse
|
35
|
Yang J, Li L, Shemetov AA, Lee S, Zhao Y, Liu Y, Shen Y, Li J, Oka Y, Verkhusha VV, Wang LV. Focusing light inside live tissue using reversibly switchable bacterial phytochrome as a genetically encoded photochromic guide star. SCIENCE ADVANCES 2019; 5:eaay1211. [PMID: 31844671 PMCID: PMC6905864 DOI: 10.1126/sciadv.aay1211] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Accepted: 10/09/2019] [Indexed: 05/14/2023]
Abstract
Focusing light deep by engineering wavefronts toward guide stars inside scattering media has potential biomedical applications in imaging, manipulation, stimulation, and therapy. However, the lack of endogenous guide stars in biological tissue hinders its translations to in vivo applications. Here, we use a reversibly switchable bacterial phytochrome protein as a genetically encoded photochromic guide star (GePGS) in living tissue to tag photons at targeted locations, achieving light focusing inside the tissue by wavefront shaping. As bacterial phytochrome-based GePGS absorbs light differently upon far-red and near-infrared illumination, a large dynamic absorption contrast can be created to tag photons inside tissue. By modulating the GePGS at a distinctive frequency, we suppressed the competition between GePGS and tissue motions and formed tight foci inside mouse tumors in vivo and acute mouse brain tissue, thus improving light delivery efficiency and specificity. Spectral multiplexing of GePGS proteins with different colors is an attractive possibility.
Collapse
Affiliation(s)
- Jiamiao Yang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Lei Li
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Anton A. Shemetov
- Department of Anatomy and Structural Biology, and Gruss Lipper Biophotonics Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Sangjun Lee
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Yuan Zhao
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Yan Liu
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Yuecheng Shen
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Jingwei Li
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Yuki Oka
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Vladislav V. Verkhusha
- Department of Anatomy and Structural Biology, and Gruss Lipper Biophotonics Center, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | - Lihong V. Wang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| |
Collapse
|
36
|
Zhu K, Zhou B, Lu Y, Lai P, Zhang S, Tan Y. Ultrasound-modulated laser feedback tomography in the reflective mode. OPTICS LETTERS 2019; 44:5414-5417. [PMID: 31730071 DOI: 10.1364/ol.44.005414] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Accepted: 10/10/2019] [Indexed: 06/10/2023]
Abstract
A novel method of ultrasound-modulated optical tomography (UOT) detection based on the laser feedback technology is proposed in this Letter. The system has advantages such as a simple structure, high sensitivity, and reflective configuration. Effective penetration depths of up to 9 cm and 5 cm in phantom and biological tissues, respectively, have been demonstrated experimentally. The detection capability is comparable with the state of the art in the transmission mode but with a much lower photon consumption. Although a lot remains to be improved, the proposed method is promising for further development toward practical applications.
Collapse
|
37
|
Johansson JD, Portaluppi D, Buttafava M, Villa F. A multipixel diffuse correlation spectroscopy system based on a single photon avalanche diode array. JOURNAL OF BIOPHOTONICS 2019; 12:e201900091. [PMID: 31339649 DOI: 10.1002/jbio.201900091] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 07/19/2019] [Accepted: 07/21/2019] [Indexed: 05/21/2023]
Abstract
The autocorrelation of laser speckles from coherent near infrared light is used for noninvasive estimates of relative changes in blood perfusion in techniques such as laser Doppler flowmetry (LDF) and diffuse correlation spectroscopy (DCS). In this study, a 2D array of single photon avalanche diodes (SPADs) was used to combine the strengths of multiple detectors in LDF with high light sensitivity in DCS. The system was tested on milk phantoms with varying detector fiber diameter (200 and 600 μm), source-detector fiber separation (4.6-10.2 mm), fiber-SPAD distance (2.5-36.5 mm), contiguous measurement time per repetition for the autocorrelation (1-33 ms) and temperature (15.6-46.7°C). An in vivo blood occlusion test was also performed. The multipixel approach improved signal-to-noise ratio (SNR) and, in our setup, the use of a multimode detector fiber was beneficial for SNR. In conclusion, the multipixel system works, but improvements and further studies regarding, for example, the data acquisition and optimal settings are still needed.
Collapse
Affiliation(s)
| | - Davide Portaluppi
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Mauro Buttafava
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| | - Federica Villa
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
| |
Collapse
|
38
|
Kho E, de Boer LL, Post AL, Van de Vijver KK, Jóźwiak K, Sterenborg HJCM, Ruers TJM. Imaging depth variations in hyperspectral imaging: Development of a method to detect tumor up to the required tumor-free margin width. JOURNAL OF BIOPHOTONICS 2019; 12:e201900086. [PMID: 31290280 DOI: 10.1002/jbio.201900086] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Revised: 05/20/2019] [Accepted: 07/09/2019] [Indexed: 06/09/2023]
Abstract
Hyperspectral imaging is a promising technique for resection margin assessment during cancer surgery. Thereby, only a specific amount of the tissue below the resection surface, the clinically defined margin width, should be assessed. Since the imaging depth of hyperspectral imaging varies with wavelength and tissue composition, this can have consequences for the clinical use of hyperspectral imaging as margin assessment technique. In this study, a method was developed that allows for hyperspectral analysis of resection margins in breast cancer. This method uses the spectral slope of the diffuse reflectance spectrum at wavelength regions where the imaging depth in tumor and healthy tissue is equal. Thereby, tumor can be discriminated from healthy breast tissue while imaging up to a similar depth as the required tumor-free margin width of 2 mm. Applying this method to hyperspectral images acquired during surgery would allow for robust margin assessment of resected specimens. In this paper, we focused on breast cancer, but the same approach can be applied to develop a method for other types of cancer.
Collapse
Affiliation(s)
- Esther Kho
- Department of Surgery, Netherlands Cancer Institute, Amsterdam, the Netherlands
| | - Lisanne L de Boer
- Department of Surgery, Netherlands Cancer Institute, Amsterdam, the Netherlands
| | - Anouk L Post
- Department of Surgery, Netherlands Cancer Institute, Amsterdam, the Netherlands
- Department of Biomedical Engineering and Physics, Amsterdam University Medical Center, Amsterdam, Netherlands
| | - Koen K Van de Vijver
- Department of Pathology, the Netherlands Cancer Institute, Amsterdam, Netherlands
- Department of Pathology, Ghent University Hospital, Ghent, Belgium
| | - Katarzyna Jóźwiak
- Department of Epidemiology and Biostatistics, the Netherlands Cancer Institute, Amsterdam, Netherlands
| | - Henricus J C M Sterenborg
- Department of Surgery, Netherlands Cancer Institute, Amsterdam, the Netherlands
- Department of Biomedical Engineering and Physics, Amsterdam University Medical Center, Amsterdam, Netherlands
| | - Theo J M Ruers
- Department of Surgery, Netherlands Cancer Institute, Amsterdam, the Netherlands
- Faculty of Science and Technology, University of Twente, Enschede, Netherlands
| |
Collapse
|
39
|
Near-infrared absorbing nanoemulsions as nonlinear ultrasound contrast agents for cancer theranostics. J Mol Liq 2019. [DOI: 10.1016/j.molliq.2019.04.125] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
40
|
Wu Z, Li L, Yang Y, Hu P, Li Y, Yang SY, Wang LV, Gao W. A microrobotic system guided by photoacoustic computed tomography for targeted navigation in intestines in vivo. Sci Robot 2019; 4:eaax0613. [PMID: 32632399 PMCID: PMC7337196 DOI: 10.1126/scirobotics.aax0613] [Citation(s) in RCA: 231] [Impact Index Per Article: 46.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Recently, tremendous progress in synthetic micro/nanomotors in diverse environment has been made for potential biomedical applications. However, existing micro/nanomotor platforms are inefficient for deep tissue imaging and motion control in vivo. Here, we present a photoacoustic computed tomography (PACT) guided investigation of micromotors in intestines in vivo. The micromotors enveloped in microcapsules are stable in the stomach and exhibit efficient propulsion in various biofluids once released. The migration of micromotor capsules toward the targeted regions in intestines has been visualized by PACT in real time in vivo. Near-infrared light irradiation induces disintegration of the capsules to release the cargo-loaded micromotors. The intensive propulsion of the micromotors effectively prolongs the retention in intestines. The integration of the newly developed microrobotic system and PACT enables deep imaging and precise control of the micromotors in vivo and promises practical biomedical applications, such as drug delivery.
Collapse
Affiliation(s)
- Zhiguang Wu
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Lei Li
- Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Yiran Yang
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Peng Hu
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Yang Li
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - So-Yoon Yang
- Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Lihong V. Wang
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
- Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Wei Gao
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
| |
Collapse
|
41
|
Ishijima A, Yagyu U, Kitamura K, Tsukamoto A, Sakuma I, Nakagawa K. Nonlinear photoacoustic waves for light guiding to deep tissue sites. OPTICS LETTERS 2019; 44:3006-3009. [PMID: 31199367 DOI: 10.1364/ol.44.003006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Accepted: 05/17/2019] [Indexed: 06/09/2023]
Abstract
Light scattering by tissues limits performance in biological sensing or stimulation. Here we present a photoacoustic technique that increases light transmittance by one order of magnitude and enables light localization in deep tissue. Laser-induced nonlinear acoustic waves are utilized to produce a high refractive index contrast in scattering medium without high-intensity pressure. The size of guiding area is around 60 μm, which is equivalent or smaller than the diameter of multimode fibers. To show potential use in biomedical fields, we performed light guiding and imaging of fluorescence, through swine tissues with thickness more than 1 mm.
Collapse
|
42
|
Mc Larney B, Rebling J, Chen Z, Deán-Ben XL, Gottschalk S, Razansky D. Uniform light delivery in volumetric optoacoustic tomography. JOURNAL OF BIOPHOTONICS 2019; 12:e201800387. [PMID: 30701679 DOI: 10.1002/jbio.201800387] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Revised: 01/28/2019] [Accepted: 01/29/2019] [Indexed: 05/03/2023]
Abstract
Accurate image reconstruction in volumetric optoacoustic tomography implies the efficient generation and collection of ultrasound signals around the imaged object. Non-uniform delivery of the excitation light is a common problem in optoacoustic imaging often leading to a diminished field of view, limited dynamic range and penetration, as well as impaired quantification abilities. Presented here is an optimized illumination concept for volumetric tomography that utilizes additive manufacturing via 3D printing in combination with custom-made optical fiber illumination. The custom-designed sample chamber ensures convenient access to the imaged object along with accurate positioning of the sample and a matrix array ultrasound transducer used for collection of the volumetric image data. Ray tracing is employed to optimize the positioning of the individual fibers in the chamber. Homogeneity of the generated light excitation field was confirmed in tissue-mimicking agar spheres. Applicability of the system to image entire mouse organs ex vivo has been showcased. The new approach showed a clear advantage over conventional, single-sided illumination strategies by eliminating the need to correct for illumination variances and resulting in enhancement of the effective field of view, greater penetration depth and significant improvements in the overall image quality.
Collapse
Affiliation(s)
- Benedict Mc Larney
- Institute for Biological and Medical Imaging, Helmholtz Center Munich, Neuherberg, Germany
- Faculty of Medicine, Technical University of Munich, Munich, Germany
| | - Johannes Rebling
- Institute for Biological and Medical Imaging, Helmholtz Center Munich, Neuherberg, Germany
- Faculty of Medicine, Technical University of Munich, Munich, Germany
- Faculty of Medicine and Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland
- Institute for Biomedical Engineering and Department of Information Technology and Electrical Engineering, ETH Zurich, Zurich, Switzerland
| | - Zhenyue Chen
- Institute for Biological and Medical Imaging, Helmholtz Center Munich, Neuherberg, Germany
| | - Xosé Luís Deán-Ben
- Institute for Biological and Medical Imaging, Helmholtz Center Munich, Neuherberg, Germany
- Faculty of Medicine and Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland
- Institute for Biomedical Engineering and Department of Information Technology and Electrical Engineering, ETH Zurich, Zurich, Switzerland
| | - Sven Gottschalk
- Institute for Biological and Medical Imaging, Helmholtz Center Munich, Neuherberg, Germany
| | - Daniel Razansky
- Institute for Biological and Medical Imaging, Helmholtz Center Munich, Neuherberg, Germany
- Faculty of Medicine, Technical University of Munich, Munich, Germany
- Faculty of Medicine and Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland
- Institute for Biomedical Engineering and Department of Information Technology and Electrical Engineering, ETH Zurich, Zurich, Switzerland
| |
Collapse
|
43
|
Chandramoorthi S, Thittai AK. Enhancing Image Quality of Photoacoustic Tomography Using Sub-Pitch Array Translation Approach: Simulation and Experimental Validation. IEEE Trans Biomed Eng 2019; 66:3543-3552. [PMID: 30932824 DOI: 10.1109/tbme.2019.2907559] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE The purpose of this paper is to present a more convenient and practical alternate way of increasing the lateral discrete array sampling while using a typical λ pitch linear array transducer at receive for photoacoustic tomography (PAT) application. METHODS We have employed a linear translation-based approach, in which the array transducer is translated by sub-pitch amount to create an augmented RF frame data having denser lateral spatial sampling. The denser λ/2 and λ/4 pitch data were reconstructed and compared against conventional λ pitch reconstructed PAT image using simulation and tissue mimicking phantom experiments in terms of improvements in resolution and contrast. RESULTS The results from experiments demonstrate a 34.48% improvement in lateral resolution (LR), measured in terms of full-width at half-maximum of the lateral profile of point spread function, and a maximum of 7-dB improvement in contrast is achieved while using a λ/2-pitch configuration when compared to the conventional λ-pitch configuration. CONCLUSION It was demonstrated that λ/2- and λ/4-pitch configurations result in better LR and contrast than λ-pitch configuration. SIGNIFICANCE Based on the results obtained, the proposed method has the potential to serve as an easy-to-integrate and simple way of achieving better image quality without requiring to increase the system complexity with existing transducer array probe technology in regular clinical scanners.
Collapse
|
44
|
Yang J, Li J, He S, Wang LV. Angular-spectrum modeling of focusing light inside scattering media by optical phase conjugation. OPTICA 2019; 6:250-256. [PMID: 32025534 PMCID: PMC7002031 DOI: 10.1364/optica.6.000250] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Accepted: 01/29/2019] [Indexed: 05/24/2023]
Abstract
Focusing light inside scattering media by optical phase conjugation has been intensively investigated due to its potential applications, such as in deep tissue imaging. However, no existing physical models explain the impact of the various factors on the focusing performance inside a dynamic scattering medium. Here, we establish an angular- spectrum model to trace the field propagation during the entire optical phase conjugation process in the presence of scattering media. By incorporating fast decorrelation components, the model enables us to investigate the com- petition between the guide star and fast tissue motions for photon tagging. Other factors affecting the focusing performance are also analyzed via the model. As a proof of concept, we experimentally verify our model in the case of focusing light through dynamic scattering media. This angular-spectrum model allows analysis of a series of scattering events in highly scattering media and benefits related applications.
Collapse
Affiliation(s)
- Jiamiao Yang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California 91125, USA
| | - Jingwei Li
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California 91125, USA
- Centre for Optical and Electromagnetic Research, Chinese National Engineering Research Center for Optical Instruments, Zhejiang University, Hangzhou 310058, China
| | - Sailing He
- Centre for Optical and Electromagnetic Research, Chinese National Engineering Research Center for Optical Instruments, Zhejiang University, Hangzhou 310058, China
| | - Lihong V. Wang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California 91125, USA
| |
Collapse
|
45
|
Hernandez-Quintanar L, Rodriguez-Salvador M. Discovering new 3D bioprinting applications: Analyzing the case of optical tissue phantoms. Int J Bioprint 2018; 5:178. [PMID: 32596533 PMCID: PMC7294689 DOI: 10.18063/ijb.v5i1.178] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Accepted: 12/18/2018] [Indexed: 11/25/2022] Open
Abstract
Optical tissue phantoms enable to mimic the optical properties of biological tissues for biomedical device calibration, new equipment validation, and clinical training for the detection, and treatment of diseases. Unfortunately, current methods for their development present some problems, such as a lack of repeatability in their optical properties. Where the use of three-dimensional (3D) printing or 3D bioprinting could address these issues. This paper aims to evaluate the use of this technology in the development of optical tissue phantoms. A competitive technology intelligence methodology was applied by analyzing Scopus, Web of Science, and patents from January 1, 2000, to July 31, 2018. The main trends regarding methods, materials, and uses, as well as predominant countries, institutions, and journals, were determined. The results revealed that, while 3D printing is already employed (in total, 108 scientific papers and 18 patent families were identified), 3D bioprinting is not yet applied for optical tissue phantoms. Nevertheless, it is expected to have significant growth. This research gives biomedical scientists a new window of opportunity for exploring the use of 3D bioprinting in a new area that may support testing of new equipment and development of techniques for the diagnosis and treatment of diseases.
Collapse
|
46
|
Urban BE, Xiao L, Chen S, Yang H, Dong B, Kozorovitskiy Y, Zhang HF. In Vivo Superresolution Imaging of Neuronal Structure in the Mouse Brain. IEEE Trans Biomed Eng 2018; 65:232-238. [PMID: 29267161 DOI: 10.1109/tbme.2017.2773540] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE this study proposes and evaluates a technique for in vivo deep-tissue superresolution imaging in the light-scattering mouse brain at up to a 3.5 Hz 2-D imaging rate with a 21×21 μm2 field of view. METHODS we combine the deep-tissue penetration and high imaging speed of resonant laser scanning two-photon (2P) microscopy with the superresolution ability of patterned excitation microscopy. Using high-frequency intensity modulation of the scanned two-photon excitation beam, we generate patterned illumination at the imaging plane. Using the principles of structured illumination, the high-frequency components in the collected images are then used to reconstruct images with an approximate twofold increase in optical resolution. RESULTS using our technique, resonant 2P superresolution patterned excitation reconstruction microscopy, we demonstrate our ability to investigate nanoscopic neuronal architecture in the cerebral cortex of the mouse brain at a depth of 120 μm in vivo and 210 μm ex vivo with a resolution of 119 nm. This technique optimizes the combination of speed and depth for improved in vivo imaging in the rodent neocortex. CONCLUSION this study demonstrates a potentially useful technique for superresolution in vivo investigations in the rodent brain in deep tissue, creating a platform for investigating nanoscopic neuronal dynamics. SIGNIFICANCE this technique optimizes the combination of speed and depth for improved superresolution in vivo imaging in the rodent neocortex.
Collapse
|
47
|
Li L, Shemetov AA, Baloban M, Hu P, Zhu L, Shcherbakova DM, Zhang R, Shi J, Yao J, Wang LV, Verkhusha VV. Small near-infrared photochromic protein for photoacoustic multi-contrast imaging and detection of protein interactions in vivo. Nat Commun 2018; 9:2734. [PMID: 30013153 PMCID: PMC6048155 DOI: 10.1038/s41467-018-05231-3] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Accepted: 06/15/2018] [Indexed: 12/11/2022] Open
Abstract
Photoacoustic (PA) computed tomography (PACT) benefits from genetically encoded probes with photochromic behavior, which dramatically increase detection sensitivity and specificity through photoswitching and differential imaging. Starting with a DrBphP bacterial phytochrome, we have engineered a near-infrared photochromic probe, DrBphP-PCM, which is superior to the full-length RpBphP1 phytochrome previously used in differential PACT. DrBphP-PCM has a smaller size, better folding, and higher photoswitching contrast. We have imaged both DrBphP-PCM and RpBphP1 simultaneously on the basis of their unique signal decay characteristics, using a reversibly switchable single-impulse panoramic PACT (RS-SIP-PACT) with a single wavelength excitation. The simple structural organization of DrBphP-PCM allows engineering a bimolecular PA complementation reporter, a split version of DrBphP-PCM, termed DrSplit. DrSplit enables PA detection of protein-protein interactions in deep-seated mouse tumors and livers, achieving 125-µm spatial resolution and 530-cell sensitivity in vivo. The combination of RS-SIP-PACT with DrBphP-PCM and DrSplit holds great potential for noninvasive multi-contrast deep-tissue functional imaging.
Collapse
Affiliation(s)
- Lei Li
- Caltech Optical Imaging Laboratory, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
| | - Anton A Shemetov
- Department of Anatomy and Structural Biology, and Gruss-Lipper Biophotonics Center, Albert Einstein College of Medicine, Bronx, NY, 10461, USA
| | - Mikhail Baloban
- Department of Anatomy and Structural Biology, and Gruss-Lipper Biophotonics Center, Albert Einstein College of Medicine, Bronx, NY, 10461, USA
| | - Peng Hu
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
| | - Liren Zhu
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
| | - Daria M Shcherbakova
- Department of Anatomy and Structural Biology, and Gruss-Lipper Biophotonics Center, Albert Einstein College of Medicine, Bronx, NY, 10461, USA
| | - Ruiying Zhang
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
| | - Junhui Shi
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
| | - Junjie Yao
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Lihong V Wang
- Caltech Optical Imaging Laboratory, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA.
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, 91125, USA.
| | - Vladislav V Verkhusha
- Department of Anatomy and Structural Biology, and Gruss-Lipper Biophotonics Center, Albert Einstein College of Medicine, Bronx, NY, 10461, USA.
- Medicum, Faculty of Medicine, University of Helsinki, 00290, Helsinki, Finland.
| |
Collapse
|
48
|
Ghita A, Matousek P, Stone N. Sensitivity of Transmission Raman Spectroscopy Signals to Temperature of Biological Tissues. Sci Rep 2018; 8:8379. [PMID: 29849076 PMCID: PMC5976642 DOI: 10.1038/s41598-018-25465-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Accepted: 04/03/2018] [Indexed: 01/26/2023] Open
Abstract
Optical properties of biological tissues can be influenced by their temperature, thus affecting light transport inside the sample. This could potentially be exploited to deliver more photons inside large biological samples, when compared with experiments at room temperature, overcoming some of difficulties due to highly scattering nature of the tissue. Here we report a change in light transmitted inside biological tissue with temperature elevation from 20 to 40 °C, indicating a considerable enhancement of photons collected by the detector in transmission geometry. The measurement of Raman signals in porcine tissue samples, as large as 40 mm in thickness, indicates a considerable increase in signal ranging from 1.3 to 2 fold, subject to biological variability. The enhancements observed are ascribed to phase transitions of lipids in biological samples. This indicates that: 1) experiments performed on tissue at room temperature can lead to an underestimation of signals that would be obtained at depth in the body in vivo and 2) that experiments at room temperature could be modified to increase detection limits by elevating the temperature of the material of interest.
Collapse
Affiliation(s)
- Adrian Ghita
- School of Physics and Astronomy, University of Exeter, Streatham Campus, EX4 4QL, Exeter, UK
| | - Pavel Matousek
- Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, Harwell Oxford, OX11 0QX, UK
| | - Nick Stone
- School of Physics and Astronomy, University of Exeter, Streatham Campus, EX4 4QL, Exeter, UK.
| |
Collapse
|
49
|
Rodell CB, Arlauckas SP, Cuccarese MF, Garris CS, Li R, Ahmed MS, Kohler RH, Pittet MJ, Weissleder R. TLR7/8-agonist-loaded nanoparticles promote the polarization of tumour-associated macrophages to enhance cancer immunotherapy. Nat Biomed Eng 2018; 2:578-588. [PMID: 31015631 PMCID: PMC6192054 DOI: 10.1038/s41551-018-0236-8] [Citation(s) in RCA: 644] [Impact Index Per Article: 107.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Accepted: 04/13/2018] [Indexed: 12/21/2022]
Abstract
Tumour-associated macrophages (TAMs) are abundant in many cancers, and often display an immune-suppressive M2-like phenotype that fosters tumour growth and promotes resistance to therapy. Yet macrophages are highly plastic and can also acquire an anti-tumourigenic M1-like phenotype. Here, we show that R848, an agonist of the toll-like receptors (TLRs) TLR7 and TLR8 identified in a morphometric-based screen, is a potent driver of the M1 phenotype in vitro and that R848-loaded β-cyclodextrin nanoparticles (CDNPs) lead to efficient drug delivery to TAMs in vivo. As a monotherapy, the administration of CDNP-R848 in multiple tumour models in mice altered the functional orientation of the tumour immune microenvironment towards an M1 phenotype, leading to controlled tumour growth and protecting the animals against tumour rechallenge. When used in combination with the immune checkpoint inhibitor anti-PD-1, we observed improved immunotherapy response rates, also in a tumour model resistant to anti-PD-1 therapy. Our findings demonstrate the ability of rationally engineered drug–nanoparticle combinations to efficiently modulate TAMs for cancer immunotherapy.
Collapse
|
50
|
Arabul MU, Heres HM, Rutten MCM, van Sambeek MRHM, van de Vosse FN, Lopata RGP. Investigation on the Effect of Spatial Compounding on Photoacoustic Images of Carotid Plaques in the In Vivo Available Rotational Range. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2018; 65:440-447. [PMID: 29505410 DOI: 10.1109/tuffc.2018.2792903] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Photoacoustic imaging (PAI) is a promising imaging modality due to its high optical specificity. However, the low signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of in vivo PA images are major challenges that prevent PAI from finding its place in clinics. This paper investigates the merit of spatial compounding of PA images in arterial phantoms and the achievable improvements of SNR, when in vivo conditions are mimicked. The analysis of the compounding technique was performed on a polyvinyl alcohol vessel phantom with black threads embedded in its wall. The in vivo conditions were mimicked by limiting the rotation range in ±30°, adding turbid surrounding medium, and filling the lumen with porcine blood. Finally, the performance of the technique was evaluated in ex vivo human carotid plaque samples. Results showed that spatial compounding elevates the SNR by 5-10 dB and CNR by 1-5 dB, depending on the location of the absorbers. This paper elucidates prospective in vivo PA characterization of carotid plaques by proposing a method to enhance PA image quality.
Collapse
|