1
|
Wang R, Zhang H, Li S, Yan P, Shao S, Liu B, Li N. Current progress of in vitrovascular models on microfluidic chips. Biofabrication 2025; 17:022004. [PMID: 39899982 DOI: 10.1088/1758-5090/adb182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2024] [Accepted: 02/03/2025] [Indexed: 02/05/2025]
Abstract
The vascular tissue, as an integral component of the human circulatory system, plays a crucial role in retaining normal physiological functions within the body. Pathologies associated with the vasculature, whether direct or indirect, also constitute significant public health concerns that afflict humanity, leading to the wide studies on vascular physiology and pathophysiology. Given the precious nature of human derived vascular tissue, substantial efforts have been dedicated to the construction of vascular models. Due to the high cost associated with animal experimentation and the inability to directly translate results to human, there is an increasing emphasis on the use of primary human cells for the development ofin vitrovascular models. For instance, obtaining an ApoE-/-mouse model for atherosclerosis research typically requires feeding a high-fat diet for over 10 weeks, whereasin vitrovascular models can usually be formed within 2 weeks. With advancements in microfluidic technology,in vitrovascular models capable of precisely emulating the hemodynamic environment within human vessels are becoming increasingly sophisticated. Microfluidic vascular models are primarily constructed through two approaches: (1) directly constructing the vascular models based on the three-layer structure of the vascular wall; (2) co-culture of endothelial cells and supporting cells within hydrogels. The former is effective to replicate vascular tissue structure mimicking vascular wall, while the latter has the capacity to establish microvascular networks. This review predominantly presents and discusses recent advancements in template design, construction methods, and potential applications of microfluidic vascular models based on polydimethylsiloxane (PDMS) soft lithography. Additionally, some refined methodologies addressing the limitations of conventional PDMS-based soft lithography techniques are also elaborated, which might hold profound importance in the field of vascular tissue engineering on microfluidic chips.
Collapse
Affiliation(s)
- Ran Wang
- Cancer Hospital of Dalian University of Technology, Shenyang 110042, People's Republic of China
- Faculty of Medicine, Dalian University of Technology, Dalian 116024, People's Republic of China
| | - Hangyu Zhang
- Cancer Hospital of Dalian University of Technology, Shenyang 110042, People's Republic of China
- Faculty of Medicine, Dalian University of Technology, Dalian 116024, People's Republic of China
- Liaoning Key Lab of Integrated Circuit and Biomedical Electronic System, Dalian University of Technology, Dalian 116024, People's Republic of China
| | - Shijun Li
- Department of Cardiology, Central Hospital of Dalian University of Technology, Dalian 116033, People's Republic of China
| | - Peishi Yan
- Department of Cardiology, Central Hospital of Dalian University of Technology, Dalian 116033, People's Republic of China
| | - Shuai Shao
- Cancer Hospital of Dalian University of Technology, Shenyang 110042, People's Republic of China
- Faculty of Medicine, Dalian University of Technology, Dalian 116024, People's Republic of China
- Liaoning Key Lab of Integrated Circuit and Biomedical Electronic System, Dalian University of Technology, Dalian 116024, People's Republic of China
| | - Bo Liu
- Cancer Hospital of Dalian University of Technology, Shenyang 110042, People's Republic of China
- Faculty of Medicine, Dalian University of Technology, Dalian 116024, People's Republic of China
- Liaoning Key Lab of Integrated Circuit and Biomedical Electronic System, Dalian University of Technology, Dalian 116024, People's Republic of China
| | - Na Li
- Cancer Hospital of Dalian University of Technology, Shenyang 110042, People's Republic of China
- Faculty of Medicine, Dalian University of Technology, Dalian 116024, People's Republic of China
- Liaoning Key Lab of Integrated Circuit and Biomedical Electronic System, Dalian University of Technology, Dalian 116024, People's Republic of China
| |
Collapse
|
2
|
Santillán-Cortez D, Castell-Rodríguez AE, González-Arenas A, Suárez-Cuenca JA, Pérez-Koldenkova V, Añorve-Bailón D, Toledo-Lozano CG, García S, Escamilla-Tilch M, Mondragón-Terán P. A Versatile Microfluidic Device System that Lacks a Synthetic Extracellular Matrix Recapitulates the Blood-Brain Barrier and Dynamic Tumor Cell Interaction. Bioengineering (Basel) 2024; 11:1008. [PMID: 39451383 PMCID: PMC11505467 DOI: 10.3390/bioengineering11101008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2024] [Revised: 09/26/2024] [Accepted: 09/26/2024] [Indexed: 10/26/2024] Open
Abstract
Microfluidic systems offer controlled microenvironments for cell-to-cell and cell-to-stroma interactions, which have precise physiological, biochemical, and mechanical features. The optimization of their conditions to best resemble tumor microenvironments constitutes an experimental modeling challenge, particularly regarding carcinogenesis in the central nervous system (CNS), given the specific features of the blood-brain barrier (BBB). Gel-free 3D microfluidic cell culture systems (gel-free 3D-mFCCSs), including features such as self-production of extracellular matrices, provide significant benefits, including promoting cell-cell communication, interaction, and cell polarity. The proposed microfluidic system consisted of a gel-free culture device inoculated with human brain microvascular endothelial cells (HBEC5i), glioblastoma multiforme cells (U87MG), and astrocytes (ScienCell 1800). The gel-free 3D-mFCCS showed a diffusion coefficient of 4.06 × 10-9 m2·s-1, and it reconstructed several features and functional properties that occur at the BBB, such as the vasculogenic ability of HBEC5i and the high duplication rate of U87MG. The optimized conditions of the gel-free 3D-mFCCS allowed for the determination of cellular proliferation, invasion, and migration, with evidence of both physical and biochemical cellular interactions, as well as the production of pro-inflammatory cytokines. In conclusion, the proposed gel-free 3D-mFCCSs represent a versatile and suitable alternative to microfluidic systems, replicating several features that occur within tumor microenvironments in the CNS. This research contributes to the characterization of microfluidic approaches and could lead to a better understanding of tumor biology and the eventual development of personalized therapies.
Collapse
Affiliation(s)
- Daniel Santillán-Cortez
- Laboratorio de Medicina Regenerativa e Ingeniería de Tejidos, Centro Médico Nacional ‘20 de Noviembre’, Instituto de Seguridad y Servicios So Ciales para los Trabajadores del Estado, San Lorenzo 502, 3er Piso. Col. Del Valle, Del. Benito Juárez, Mexico City 03100, Mexico
| | - Andrés Eliú Castell-Rodríguez
- Laboratorio de Medicina Regenerativa e Inmunoterapia Experimental, Departamento de Biología Celular y Tisular, Facultad de Medicina-Universidad Nacional Autónoma de México, Ciudad Universitaria, Mexico City 04510, Mexico;
| | - Aliesha González-Arenas
- Departamento Medicina Genómica y Toxicología Ambiental, Instituto de Investigaciónes Biomédicas-Universidad Nacional Autónoma de México, Circuito de la Investigación Científica, Ciudad Universitaria, Coyoacán, Mexico City 04510, Mexico;
| | - Juan Antonio Suárez-Cuenca
- Experimental Metabolism and Clinical Research Laboratory, Clinical Research Department, Division of Biomedical Research, Centro Médico Nacional ‘20 de Noviembre’, Instituto de Seguridad y Servicios Sociales para los Trabajadores del Estado, Mexico City 03229, Mexico;
| | - Vadim Pérez-Koldenkova
- Laboratorio Nacional de Microscopía Avanzada, Centro Médico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Mexico City 06720, Mexico
| | - Denisse Añorve-Bailón
- Subdireccion de Investigacion, Centro Médico Nacional ‘20 de Noviembre’—ISSSTE, San Lorenzo 502, 2do Piso. Col. Del Valle, Del. Benito Juárez, Mexico City 03100, Mexico
| | - Christian Gabriel Toledo-Lozano
- Coordinación de Investigación, Centro Médico Nacional ‘20 de Noviembre’, Instituto de Seguridad y Servicios Sociales para los Trabajadores del Estado, Mexico City 03229, Mexico
| | - Silvia García
- Coordinación de Investigación, Centro Médico Nacional ‘20 de Noviembre’, Instituto de Seguridad y Servicios Sociales para los Trabajadores del Estado, Mexico City 03229, Mexico
| | - Mónica Escamilla-Tilch
- Laboratorio de Inmunogenética, Centro Médico Nacional ‘20 de Noviembre’, Instituto de Seguridad y Servicios Sociales para los Trabajadores del Estado, Mexico City 03229, Mexico;
| | - Paul Mondragón-Terán
- Laboratorio de Medicina Regenerativa e Ingeniería de Tejidos, Centro Médico Nacional ‘20 de Noviembre’, Instituto de Seguridad y Servicios So Ciales para los Trabajadores del Estado, San Lorenzo 502, 3er Piso. Col. Del Valle, Del. Benito Juárez, Mexico City 03100, Mexico
- Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada Unidad Morelos, Instituto Polítecnico Nacional, Boulevard de la Tecnología, 1036 Z-1, P 2/2, Atlacholoaya 62790, Mexico
| |
Collapse
|
3
|
Bathrinarayanan PV, Hallam SM, Grover LM, Vigolo D, Simmons MJH. Microfluidics as a Powerful Tool to Investigate Microvascular Dysfunction in Trauma Conditions: A Review of the State-of-the-Art. Adv Biol (Weinh) 2024; 8:e2400037. [PMID: 39031943 DOI: 10.1002/adbi.202400037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 04/18/2024] [Indexed: 07/22/2024]
Abstract
Skeletal muscle trauma such as fracture or crush injury can result in a life-threatening condition called acute compartment syndrome (ACS), which involves elevated compartmental pressure within a closed osteo-fascial compartment, leading to collapse of the microvasculature and resulting in necrosis of the tissue due to ischemia. Diagnosis of ACS is complex and controversial due to the lack of standardized objective methods, which results in high rates of misdiagnosis/late diagnosis, leading to permanent neuro-muscular damage. ACS pathophysiology is poorly understood at a cellular level due to the lack of physiologically relevant models. In this context, microfluidics organ-on-chip systems (OOCs) provide an exciting opportunity to investigate the cellular mechanisms of microvascular dysfunction that leads to ACS. In this article, the state-of-the-art OOCs designs and strategies used to investigate microvasculature dysfunction mechanisms is reviewed. The differential effects of hemodynamic shear stress on endothelial cell characteristics such as morphology, permeability, and inflammation, all of which are altered during microvascular dysfunction is highlighted. The article then critically reviews the importance of microfluidics to investigate closely related microvascular pathologies that cause ACS. The article concludes by discussing potential biomarkers of ACS with a special emphasis on glycocalyx and providing a future perspective.
Collapse
Affiliation(s)
- P Vasanthi Bathrinarayanan
- School of Chemical Engineering, University of Birmingham, Edgbaston, Birmingham, B152TT, UK
- Healthcare Technologies Institute, School of Chemical Engineering, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
| | - S M Hallam
- School of Chemical Engineering, University of Birmingham, Edgbaston, Birmingham, B152TT, UK
| | - L M Grover
- School of Chemical Engineering, University of Birmingham, Edgbaston, Birmingham, B152TT, UK
- Healthcare Technologies Institute, School of Chemical Engineering, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
| | - D Vigolo
- School of Chemical Engineering, University of Birmingham, Edgbaston, Birmingham, B152TT, UK
- The University of Sydney, School of Biomedical Engineering, Sydney, NSW, 2006, Australia
- The University of Sydney Nano Institute, The University of Sydney, Sydney, NSW, 2006, Australia
| | - M J H Simmons
- School of Chemical Engineering, University of Birmingham, Edgbaston, Birmingham, B152TT, UK
| |
Collapse
|
4
|
Du X, Jia H, Chang Y, Zhao Y, Song J. Progress of organoid platform in cardiovascular research. Bioact Mater 2024; 40:88-103. [PMID: 38962658 PMCID: PMC11220467 DOI: 10.1016/j.bioactmat.2024.05.043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 05/28/2024] [Accepted: 05/28/2024] [Indexed: 07/05/2024] Open
Abstract
Cardiovascular disease is a significant cause of death in humans. Various models are necessary for the study of cardiovascular diseases, but once cellular and animal models have some defects, such as insufficient fidelity. As a new technology, organoid has certain advantages and has been used in many applications in the study of cardiovascular diseases. This article aims to summarize the application of organoid platforms in cardiovascular diseases, including organoid construction schemes, modeling, and application of cardiovascular organoids. Advances in cardiovascular organoid research have provided many models for different cardiovascular diseases in a variety of areas, including myocardium, blood vessels, and valves. Physiological and pathological models of different diseases, drug research models, and methods for evaluating and promoting the maturation of different kinds of organ tissues are provided for various cardiovascular diseases, including cardiomyopathy, myocardial infarction, and atherosclerosis. This article provides a comprehensive overview of the latest research progress in cardiovascular organ tissues, including construction protocols for cardiovascular organoid tissues and their evaluation system, different types of disease models, and applications of cardiovascular organoid models in various studies. The problems and possible solutions in organoid development are summarized.
Collapse
Affiliation(s)
- Xingchao Du
- Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Centre, National Centre for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, Chinese Academy of Medical Science, PUMC, 167 Beilishi Road, Xicheng District, Beijing, 100037, China
| | - Hao Jia
- Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Centre, National Centre for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, Chinese Academy of Medical Science, PUMC, 167 Beilishi Road, Xicheng District, Beijing, 100037, China
| | - Yuan Chang
- Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Centre, National Centre for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, Chinese Academy of Medical Science, PUMC, 167 Beilishi Road, Xicheng District, Beijing, 100037, China
| | - Yiqi Zhao
- Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Centre, National Centre for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, Chinese Academy of Medical Science, PUMC, 167 Beilishi Road, Xicheng District, Beijing, 100037, China
| | - Jiangping Song
- Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Centre, National Centre for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, Chinese Academy of Medical Science, PUMC, 167 Beilishi Road, Xicheng District, Beijing, 100037, China
| |
Collapse
|
5
|
Özsoylu D, Aliazizi F, Wagner P, Schöning MJ. Template bacteria-free fabrication of surface imprinted polymer-based biosensor for E. coli detection using photolithographic mimics: Hacking bacterial adhesion. Biosens Bioelectron 2024; 261:116491. [PMID: 38879900 DOI: 10.1016/j.bios.2024.116491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 06/05/2024] [Accepted: 06/07/2024] [Indexed: 06/18/2024]
Abstract
As one class of molecular imprinted polymers (MIPs), surface imprinted polymer (SIP)-based biosensors show great potential in direct whole-bacteria detection. Micro-contact imprinting, that involves stamping the template bacteria immobilized on a substrate into a pre-polymerized polymer matrix, is the most straightforward and prominent method to obtain SIP-based biosensors. However, the major drawbacks of the method arise from the requirement for fresh template bacteria and often non-reproducible bacteria distribution on the stamp substrate. Herein, we developed a positive master stamp containing photolithographic mimics of the template bacteria (E. coli) enabling reproducible fabrication of biomimetic SIP-based biosensors without the need for the "real" bacteria cells. By using atomic force and scanning electron microscopy imaging techniques, respectively, the E. coli-capturing ability of the SIP samples was tested, and compared with non-imprinted polymer (NIP)-based samples and control SIP samples, in which the cavity geometry does not match with E. coli cells. It was revealed that the presence of the biomimetic E. coli imprints with a specifically designed geometry increases the sensor E. coli-capturing ability by an "imprinting factor" of about 3. These findings show the importance of geometry-guided physical recognition in bacterial detection using SIP-based biosensors. In addition, this imprinting strategy was employed to interdigitated electrodes and QCM (quartz crystal microbalance) chips. E. coli detection performance of the sensors was demonstrated with electrochemical impedance spectroscopy (EIS) and QCM measurements with dissipation monitoring technique (QCM-D).
Collapse
Affiliation(s)
- Dua Özsoylu
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428, Jülich, Germany
| | - Fereshteh Aliazizi
- Department of Physics and Astronomy, Laboratory for Soft Matter and Biophysics, KU Leuven, B-3001, Leuven, Belgium
| | - Patrick Wagner
- Department of Physics and Astronomy, Laboratory for Soft Matter and Biophysics, KU Leuven, B-3001, Leuven, Belgium
| | - Michael J Schöning
- Institute of Nano- and Biotechnologies (INB), Aachen University of Applied Sciences, Campus Jülich, 52428, Jülich, Germany; Institute of Biological Information Processing (IBI-3), Research Centre Jülich GmbH, 52425, Jülich, Germany.
| |
Collapse
|
6
|
Hu SY, Xue CD, Li YJ, Li S, Gao ZN, Qin KR. Microfluidic investigation for shear-stress-mediated repair of dysglycemia-induced endothelial cell damage. MECHANOBIOLOGY IN MEDICINE 2024; 2:100069. [DOI: 10.1016/j.mbm.2024.100069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
|
7
|
Thurgood P, Hawke A, Low LS, Borg A, Peter K, Baratchi S, Khoshmanesh K. Tube Oscillation Drives Transitory Vortices Across Microfluidic Barriers. SMALL METHODS 2024; 8:e2301427. [PMID: 38161266 DOI: 10.1002/smtd.202301427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 12/18/2023] [Indexed: 01/03/2024]
Abstract
Here, the generation of dynamic vortices across microscale barriers using the tube oscillation mechanism is demonstrated. Using a combination of high-speed imaging and computational flow dynamics, the cyclic formation, expansion, and collapse of vortices are studied. The dynamics of vortices across circular , triangular, and blade-shape barriers are investigated at different tube oscillation frequencies. The formation of an array of synchronous vortices across parallel blade-shaped barriers is demonstrated. The transient flows caused by these dynamic vortex arrays are harnessed for the rapid and efficient mixing of blood samples . A circular barrier scribed with a narrow orifice on its shoulder is used to facilitate the injection of liquid into the microfluidic channel, and its rapid mixing with the main flow through the dynamic vortices generated across the barrier. This approach facilitates the generation of vortices with desirable configurations, sizes, and dynamics in a highly controllable, programmable, and predictable manner while operating at low static flow rates.
Collapse
Affiliation(s)
- Peter Thurgood
- School of Engineering, RMIT University, Melbourne, VIC, 3000, Australia
| | - Adam Hawke
- School of Engineering, RMIT University, Melbourne, VIC, 3000, Australia
| | - Lee Sheer Low
- School of Engineering, RMIT University, Melbourne, VIC, 3000, Australia
| | - Aimee Borg
- School of Engineering, RMIT University, Melbourne, VIC, 3000, Australia
| | - Karlheinz Peter
- Baker Heart and Diabetes Institute, Melbourne, VIC, 3004, Australia
- Department of Cardiometabolic Health, The University of Melbourne, Parkville, VIC, 3010, Australia
| | - Sara Baratchi
- Baker Heart and Diabetes Institute, Melbourne, VIC, 3004, Australia
- Department of Cardiometabolic Health, The University of Melbourne, Parkville, VIC, 3010, Australia
| | | |
Collapse
|
8
|
Pandian K, Huang L, Junaid A, Harms A, van Zonneveld AJ, Hankemeier T. Tracer-based metabolomics for profiling nitric oxide metabolites in a 3D microvessels-on-chip model. FASEB J 2024; 38:e70005. [PMID: 39171967 DOI: 10.1096/fj.202400553r] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 06/19/2024] [Accepted: 08/07/2024] [Indexed: 08/23/2024]
Abstract
Endothelial dysfunction, prevalent in cardiovascular diseases (CVDs) and linked to conditions like diabetes, hypertension, obesity, renal failure, or hypercholesterolemia, is characterized by diminished nitric oxide (NO) bioavailability-a key signaling molecule for vascular homeostasis. Current two-dimensional (2D) in vitro studies on NO synthesis by endothelial cells (ECs) lack the crucial laminar shear stress, a vital factor in modulating the NO-generating enzyme, endothelial nitric oxide synthase (eNOS), under physiological conditions. Here we developed a tracer-based metabolomics approach to measure NO-specific metabolites with mass spectrometry (MS) and show the impact of fluid flow on metabolic parameters associated with NO synthesis using 2D and 3D platforms. Specifically, we tracked the conversion of stable-isotope labeled NO substrate L-Arginine to L-Citrulline and L-Ornithine to determine eNOS activity. We demonstrated clear responses in human coronary artery endothelial cells (HCAECs) cultured with 13C6, 15N4-L-Arginine, and treated with eNOS stimulator, eNOS inhibitor, and arginase inhibitor. Analysis of downstream metabolites, 13C6, 15N3 L-Citrulline and 13C5, 15N2 L-Ornithine, revealed distinct outcomes. Additionally, we evaluated the NO metabolic status in static 2D culture and 3D microvessel models with bidirectional and unidirectional fluid flow. Our 3D model exhibited significant effects, particularly in microvessels exposed to the eNOS stimulator, as indicated by the 13C6, 15N3 L-Citrulline/13C5, 15N2 L-Ornithine ratio, compared to the 2D culture. The obtained results indicate that the 2D static culture mimics an endothelial dysfunction status, while the 3D model with a unidirectional fluid flow provides a more representative physiological environment that provides a better model to study endothelial dysfunction.
Collapse
Affiliation(s)
- Kanchana Pandian
- Division of Systems Biomedicine and Pharmacology, LACDR, Leiden University, Leiden, the Netherlands
| | - Luojiao Huang
- Division of Systems Biomedicine and Pharmacology, LACDR, Leiden University, Leiden, the Netherlands
| | - Abidemi Junaid
- Division of Systems Biomedicine and Pharmacology, LACDR, Leiden University, Leiden, the Netherlands
| | - Amy Harms
- Division of Systems Biomedicine and Pharmacology, LACDR, Leiden University, Leiden, the Netherlands
| | - Anton Jan van Zonneveld
- Department of Internal Medicine (Nephrology) and the Einthoven Laboratory for Vascular and Regenerative Medicine, Leiden University Medical Center (LUMC), Leiden, the Netherlands
| | - Thomas Hankemeier
- Division of Systems Biomedicine and Pharmacology, LACDR, Leiden University, Leiden, the Netherlands
| |
Collapse
|
9
|
Gómez-Varela AI, Viña A, Bao-Varela C, Flores-Arias MT, Carnero B, González-Peteiro M, González-Juanatey JR, Álvarez E. Biocompatibility Testing of UV-Curable Polydimethylsiloxane for Human Umbilical Vein Endothelial Cell Culture on-a-Chip. ACS OMEGA 2024; 9:30281-30293. [PMID: 39035966 PMCID: PMC11256083 DOI: 10.1021/acsomega.4c01148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 06/07/2024] [Accepted: 06/12/2024] [Indexed: 07/23/2024]
Abstract
Polydimethylsiloxane (PDMS) is extensively used to fabricate biocompatible microfluidic systems due to its favorable properties for cell culture. Recently, ultraviolet-curable PDMS (UV-PDMS) has shown potential for enhancing manufacturing processes and final optical quality while retaining the benefits of traditional thermally cured PDMS. This study investigates the biocompatibility of UV-PDMS under static and flow conditions using human umbilical vein endothelial cells (HUVECs). UV-PDMS samples were treated with oxygen plasma and boiling deionized water to assess potential improvements in cell behavior compared with untreated samples. We evaluated HUVECs adhesion, growth, morphology, and viability in static cultures and microchannels fabricated with UV-PDMS to test their resistance to flow conditions. Our results confirmed the biocompatibility of UV-PDMS for HUVECs culture. Moreover, plasma-oxygen-treated UV-PDMS substrates exhibited superior cell growth and adhesion compared to untreated UV-PDMS. This enhancement enabled HUVECs to maintain their morphology and viability under flow conditions in UV-PDMS microchannels. Additionally, UV-PDMS demonstrated improved optical quality and more efficient handling and processing, characterized by shorter curing times and simplified procedures utilizing UV light compared to traditional PDMS.
Collapse
Affiliation(s)
- Ana I. Gómez-Varela
- Photonics4Life
Research Group, Departamento de Física Aplicada, Facultade
de Física and Facultade de Óptica e Optometría,
Instituto de Materiais (iMATUS), Universidade
de Santiago de Compostela, Campus Vida, Santiago de
Compostela E15782, Spain
| | - Antonio Viña
- Departamento
de Farmacología, Farmacia y Tecnología Farmacéutica, Universidade de Santiago de Compostela, Santiago de Compostela 15782, A Coruña, Spain
| | - Carmen Bao-Varela
- Photonics4Life
Research Group, Departamento de Física Aplicada, Facultade
de Física and Facultade de Óptica e Optometría,
Instituto de Materiais (iMATUS), Universidade
de Santiago de Compostela, Campus Vida, Santiago de
Compostela E15782, Spain
| | - María Teresa Flores-Arias
- Photonics4Life
Research Group, Departamento de Física Aplicada, Facultade
de Física and Facultade de Óptica e Optometría,
Instituto de Materiais (iMATUS), Universidade
de Santiago de Compostela, Campus Vida, Santiago de
Compostela E15782, Spain
| | - Bastián Carnero
- Photonics4Life
Research Group, Departamento de Física Aplicada, Facultade
de Física and Facultade de Óptica e Optometría,
Instituto de Materiais (iMATUS), Universidade
de Santiago de Compostela, Campus Vida, Santiago de
Compostela E15782, Spain
- BFlow
S.L., Edificio Emprendia, Santiago
de Compostela 15782, Spain
| | - Mercedes González-Peteiro
- Departamento
de Enfermería, Universidade de Santiago de Compostela, Santiago
de Compostela, A Coruña 15782, Spain
| | - José Ramón González-Juanatey
- Instituto
de Investigación Sanitaria de Santiago de Compostela (IDIS), Complexo Hospitalario Universitario de Santiago de
Compostela (CHUS), SERGAS.
Travesía da Choupana s/n, Santiago de
Compostela, A Coruña 15706, Spain
- Departamento
de Medicina, Universidad de Santiago de
Compostela, Santiago de Compostela 15706, A Coruña, Spain
- Servicio
de Cardiología y Unidad de Hemodinámica, Complexo Hospitalario Universitario de Santiago de
Compostela (CHUS), SERGAS, Travesía da Choupana s/n, Santiago
de Compostela 15706, A Coruña, Spain
| | - Ezequiel Álvarez
- Departamento
de Farmacología, Farmacia y Tecnología Farmacéutica, Universidade de Santiago de Compostela, Santiago de Compostela 15782, A Coruña, Spain
- Departamento
de Medicina, Universidad de Santiago de
Compostela, Santiago de Compostela 15706, A Coruña, Spain
- Servicio
de Cardiología y Unidad de Hemodinámica, Complexo Hospitalario Universitario de Santiago de
Compostela (CHUS), SERGAS, Travesía da Choupana s/n, Santiago
de Compostela 15706, A Coruña, Spain
- CIBERCV, 28029 Madrid, Spain
| |
Collapse
|
10
|
Wen K, Gorbushina AA, Schwibbert K, Bell J. Microfluidic Platform with Precisely Controlled Hydrodynamic Parameters and Integrated Features for Generation of Microvortices to Accurately Form and Monitor Biofilms in Flow. ACS Biomater Sci Eng 2024; 10:4626-4634. [PMID: 38904279 PMCID: PMC11234330 DOI: 10.1021/acsbiomaterials.4c00101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/22/2024]
Abstract
Microorganisms often live in habitats characterized by fluid flow, and their adhesion to surfaces in industrial systems or clinical settings may lead to pipe clogging, microbially influenced corrosion, material deterioration, food spoilage, infections, and human illness. Here, a novel microfluidic platform was developed to investigate biofilm formation under precisely controlled (i) cell concentration, (ii) temperature, and (iii) flow conditions. The developed platform central unit is a single-channel microfluidic flow cell designed to ensure ultrahomogeneous flow and condition in its central area, where features, e.g., with trapping properties, can be incorporated. In comparison to static and macroflow chamber assays for biofilm studies, microfluidic chips allow in situ monitoring of biofilm formation under various flow regimes and have better environment control and smaller sample requirements. Flow simulations and experiments with fluorescent particles were used to simulate bacteria flow in the platform cell for calculating flow velocity and direction at the microscale level. The combination of flow analysis and fluorescent strain injection in the cell showed that microtraps placed at the center of the channel were efficient in capturing bacteria at determined positions and to study how flow conditions, especially microvortices, can affect biofilm formation. The microfluidic platform exhibited improved performances in terms of homogeneity and robustness for in vitro biofilm formation. We anticipate the presented platform to be suitable for broad, versatile, and high-throughput biofilm studies at the microscale level.
Collapse
Affiliation(s)
- Keqing Wen
- Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, Berlin 12205, Germany
- Freie Universität Berlin, Kaiserswerther Str. 16-18, Berlin 14195, Germany
| | - Anna A Gorbushina
- Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, Berlin 12205, Germany
- Freie Universität Berlin, Kaiserswerther Str. 16-18, Berlin 14195, Germany
| | - Karin Schwibbert
- Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, Berlin 12205, Germany
| | - Jérémy Bell
- Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, Berlin 12205, Germany
| |
Collapse
|
11
|
Choi JW, Kim K, Mukhambetiyar K, Lee NK, Sabaté Del Río J, Joo J, Park CG, Kwon T, Park TE. Organ-on-a-Chip Approach for Accelerating Blood-Brain Barrier Nanoshuttle Discovery. ACS NANO 2024; 18:14388-14402. [PMID: 38775287 DOI: 10.1021/acsnano.4c00994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2024]
Abstract
Organ-on-a-chip, which recapitulates the dynamics of in vivo vasculature, has emerged as a promising platform for studying organ-specific vascular beds. However, its practical advantages in identifying vascular-targeted drug delivery systems (DDS) over traditional in vitro models remain underexplored. This study demonstrates the reliability and efficacy of the organ-on-a-chip in screening efficient DDS by comparing its performance with that of a conventional transwell, both designed to simulate the blood-brain barrier (BBB). The BBB nanoshuttles discovered through BBB Chip-based screening demonstrated superior functionality in vivo compared to those identified using transwell methods. This enhanced effectiveness is attributed to the BBB Chip's accurate replication of the structure and dynamics of the endothelial glycocalyx, a crucial protective layer within blood vessels, especially under shear stress. This capability of the BBB Chip has enabled the identification of molecular shuttles that efficiently exploit the endothelial glycocalyx, thereby enhancing transendothelial transport efficacy. Our findings suggest that organ-on-a-chip technology holds considerable promise for advancing research in vascular-targeted DDS due to its accurate simulation of molecular transport within endothelial systems.
Collapse
Affiliation(s)
- Jeong-Won Choi
- Department of Biomedical Engineering, College of Information and Biotechnology, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
- Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Allston, Massachusetts 02134, United States
| | - Kyungha Kim
- Department of Biomedical Engineering, College of Information and Biotechnology, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Karakoz Mukhambetiyar
- Department of Biomedical Engineering, College of Information and Biotechnology, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Na Kyeong Lee
- Department of Biomedical Engineering, Institute for Cross-disciplinary Studies (ICS), Sungkyunkwan University, Suwon, Gyeonggi 16419, Republic of Korea
| | - Jonathan Sabaté Del Río
- Center for Algorithmic and Robotized Synthesis (CARS), Institute for Basic Science (IBS), Ulsan 44919, Republic of Korea
| | - Jinmyoung Joo
- Department of Biomedical Engineering, College of Information and Biotechnology, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
- Center for Genomic Integrity, Institute for Basic Science, Ulsan 44919, Republic of Korea
- Graduate School of Health Science and Technology, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Chun Gwon Park
- Department of Biomedical Engineering, Institute for Cross-disciplinary Studies (ICS), Sungkyunkwan University, Suwon, Gyeonggi 16419, Republic of Korea
| | - Taejoon Kwon
- Department of Biomedical Engineering, College of Information and Biotechnology, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
- Center for Genomic Integrity, Institute for Basic Science, Ulsan 44919, Republic of Korea
| | - Tae-Eun Park
- Department of Biomedical Engineering, College of Information and Biotechnology, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| |
Collapse
|
12
|
Chandra Sekar N, Khoshmanesh K, Baratchi S. Bioengineered models of cardiovascular diseases. Atherosclerosis 2024; 393:117565. [PMID: 38714426 DOI: 10.1016/j.atherosclerosis.2024.117565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2023] [Revised: 04/15/2024] [Accepted: 04/25/2024] [Indexed: 05/09/2024]
Abstract
Age-associated cardiovascular diseases (CVDs), predominantly resulting from artery-related disorders such as atherosclerosis, stand as a leading cause of morbidity and mortality among the elderly population. Consequently, there is a growing interest in the development of clinically relevant bioengineered models of CVDs. Recent developments in bioengineering and material sciences have paved the way for the creation of intricate models that closely mimic the structure and surroundings of native cardiac tissues and blood vessels. These models can be utilized for basic research purposes and for identifying pharmaceutical interventions and facilitating drug discovery. The advancement of vessel-on-a-chip technologies and the development of bioengineered and humanized in vitro models of the cardiovascular system have the potential to revolutionize CVD disease modelling. These technologies offer pathophysiologically relevant models at a fraction of the cost and time required for traditional experimentation required in vivo. This progress signifies a significant advancement in the field, transitioning from conventional 2D cell culture models to advanced 3D organoid and vessel-on-a-chip models. These innovative models are specifically designed to explore the complexities of vascular aging and stiffening, crucial factors in the development of cardiovascular diseases. This review summarizes the recent progress of various bioengineered in vitro platforms developed for investigating the pathophysiology of human cardiovascular system with more focus on advanced 3D vascular platforms.
Collapse
Affiliation(s)
- Nadia Chandra Sekar
- School of Health & Biomedical Sciences, RMIT University, Bundoora, Victoria, 3082, Australia; Baker Heart and Diabetes Institute, Melbourne, Victoria, 3004, Australia
| | - Khashayar Khoshmanesh
- Baker Heart and Diabetes Institute, Melbourne, Victoria, 3004, Australia; School of Engineering, RMIT University, Melbourne, Victoria, 3000, Australia
| | - Sara Baratchi
- School of Health & Biomedical Sciences, RMIT University, Bundoora, Victoria, 3082, Australia; Baker Heart and Diabetes Institute, Melbourne, Victoria, 3004, Australia; Department of Cardiometabolic Health, The University of Melbourne, Parkville, Victoria, 3010, Australia.
| |
Collapse
|
13
|
Prochilo G, Pfeffer A, Du S, Kaneko N, Liebeskind DS, Hinman JD. Recent Translational Research Models of Intracranial Atherosclerotic Disease. Stroke 2024; 55:1707-1719. [PMID: 38738375 DOI: 10.1161/strokeaha.124.044520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2024]
Abstract
Intracranial atherosclerotic disease (ICAD) is a leading cause of ischemic stroke worldwide. However, research on the pathophysiology of ICAD is scarce due to the relative inaccessibility of histology samples and the lack of comprehensive experimental models. As a result, much of the current understanding of ICAD relies on research on extracranial atherosclerosis. This approach is problematic as intracranial and extracranial arteries are anatomically, structurally, physiologically, and metabolically distinct, indicating that intracranial and extracranial atherosclerosis likely develop through different biologic pathways. The current standard of care for ICAD treatment relies predominantly on therapeutics developed to treat extracranial atherosclerosis and is insufficient given the alarmingly high risk of stroke. To provide a definitive treatment for the disease, a deeper understanding of the pathophysiology underlying ICAD is specifically required. True mechanistic understanding of disease pathogenesis is only possible using robust experimental models. In this review, we aim to identify the advantages and limitations of the existing in vivo and in vitro models of ICAD and basic atherosclerotic processes, which may be used to inform better models of ICAD in the future and drive new therapeutic strategies to reduce stroke risk.
Collapse
Affiliation(s)
- Grace Prochilo
- Departments of Neurology (G.P., A.P., S.D., D.S.L., J.D.H.), David Geffen School of Medicine, University of California, Los Angeles
| | - Alissa Pfeffer
- Departments of Neurology (G.P., A.P., S.D., D.S.L., J.D.H.), David Geffen School of Medicine, University of California, Los Angeles
| | - Stephanie Du
- Departments of Neurology (G.P., A.P., S.D., D.S.L., J.D.H.), David Geffen School of Medicine, University of California, Los Angeles
| | - Naoki Kaneko
- Radiology (N.K.), David Geffen School of Medicine, University of California, Los Angeles
| | - David S Liebeskind
- Departments of Neurology (G.P., A.P., S.D., D.S.L., J.D.H.), David Geffen School of Medicine, University of California, Los Angeles
| | - Jason D Hinman
- Departments of Neurology (G.P., A.P., S.D., D.S.L., J.D.H.), David Geffen School of Medicine, University of California, Los Angeles
- Department of Neurology, Department of Veterans Affairs Medical Center, Los Angeles, CA (J.D.H.)
| |
Collapse
|
14
|
Hall E, Mendiola K, Lightsey NK, Hanjaya-Putra D. Mimicking blood and lymphatic vasculatures using microfluidic systems. BIOMICROFLUIDICS 2024; 18:031502. [PMID: 38726373 PMCID: PMC11081709 DOI: 10.1063/5.0175154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 04/04/2024] [Indexed: 05/12/2024]
Abstract
The role of the circulatory system, containing the blood and lymphatic vasculatures, within the body, has become increasingly focused on by researchers as dysfunction of either of the systems has been linked to serious complications and disease. Currently, in vivo models are unable to provide the sufficient monitoring and level of manipulation needed to characterize the fluidic dynamics of the microcirculation in blood and lymphatic vessels; thus in vitro models have been pursued as an alternative model. Microfluidic devices have the required properties to provide a physiologically relevant circulatory system model for research as well as the experimental tools to conduct more advanced research analyses of microcirculation flow. In this review paper, the physiological behavior of fluid flow and electrical communication within the endothelial cells of the systems are detailed and discussed to highlight their complexities. Cell co-culturing methods and other relevant organ-on-a-chip devices will be evaluated to demonstrate the feasibility and relevance of the in vitro microfluidic model. Microfluidic systems will be determined as a noteworthy model that can display physiologically relevant flow of the cardiovascular and lymphatic systems, which will enable researchers to investigate the systems' prevalence in diseases and identify potential therapeutics.
Collapse
Affiliation(s)
- Eva Hall
- Aerospace and Mechanical Engineering, Bioengineering Graduate Program, University of Notre Dame, Notre Dame, Indiana 46556, USA
| | | | - N. Keilany Lightsey
- Aerospace and Mechanical Engineering, Bioengineering Graduate Program, University of Notre Dame, Notre Dame, Indiana 46556, USA
| | | |
Collapse
|
15
|
Chandurkar MK, Mittal N, Royer-Weeden SP, Lehmann SD, Michels EB, Haarman SE, Severance SA, Rho Y, Han SJ. Transient low shear-stress preconditioning influences long-term endothelial traction and alignment under high shear flow. Am J Physiol Heart Circ Physiol 2024; 326:H1180-H1192. [PMID: 38457352 PMCID: PMC11649189 DOI: 10.1152/ajpheart.00067.2024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Revised: 03/01/2024] [Accepted: 03/03/2024] [Indexed: 03/10/2024]
Abstract
Endothelial cells (ECs) within the vascular system encounter fluid shear stress (FSS). High, laminar FSS promotes vasodilation and anti-inflammatory responses, whereas low or disturbed FSS induces dysfunction and inflammation. However, the adaptation of endothelial cells (ECs) to dynamically changing FSS patterns remains underexplored. Here, by combining traction force microscopy with a custom flow chamber, we examined human umbilical vein endothelial cells adapting their traction during transitions from short-term low shear to long-term high shear stress. We discovered that the initial low FSS elevates the traction by only half of the amount in response to direct high FSS even after flow changes to high FSS. However, in the long term under high FSS, the flow started with low FSS triggers a substantial second rise in traction for over 10 h. In contrast, the flow started directly with high FSS results in a quick traction surge followed by a huge reduction below the baseline traction in <30 min. Importantly, we find that the orientation of traction vectors is steered by initial shear exposure. Using Granger causality analysis, we show that the traction that aligns in the flow direction under direct high FSS functionally causes cell alignment toward the flow direction. However, EC traction that orients perpendicular to the flow that starts with temporary low FSS functionally causes cell orientation perpendicular to the flow. Taken together, our findings elucidate the significant influence of initial short-term low FSS on lasting changes in endothelial traction that induces EC alignment.NEW & NOTEWORTHY In our study, we uncover that preconditioning with low shear stress yields enduring impacts on endothelial cell traction and orientation, persisting even after transitioning to high-shear conditions. Using Granger causality analysis, we demonstrate a functional link between the direction of cell traction and subsequent cellular alignment across varying shear environments.
Collapse
Affiliation(s)
- Mohanish K Chandurkar
- Department of Biomedical Engineering, Michigan Technological University, Houghton, Michigan, United States
- Health Research Institute, Michigan Technological University, Houghton, Michigan, United States
| | - Nikhil Mittal
- Department of Biomedical Engineering, Michigan Technological University, Houghton, Michigan, United States
- Health Research Institute, Michigan Technological University, Houghton, Michigan, United States
| | - Shaina P Royer-Weeden
- Department of Biomedical Engineering, Michigan Technological University, Houghton, Michigan, United States
- Health Research Institute, Michigan Technological University, Houghton, Michigan, United States
| | - Steven D Lehmann
- Department of Biomedical Engineering, Michigan Technological University, Houghton, Michigan, United States
| | - Etienne B Michels
- Department of Biomedical Engineering, Michigan Technological University, Houghton, Michigan, United States
| | - Samuel E Haarman
- Department of Biomedical Engineering, Michigan Technological University, Houghton, Michigan, United States
- Health Research Institute, Michigan Technological University, Houghton, Michigan, United States
| | - Scott A Severance
- Department of Biomedical Engineering, Michigan Technological University, Houghton, Michigan, United States
| | - Yeonwoo Rho
- Department of Mathematical Sciences, Michigan Technological University, Houghton, Michigan, United States
| | - Sangyoon J Han
- Department of Biomedical Engineering, Michigan Technological University, Houghton, Michigan, United States
- Health Research Institute, Michigan Technological University, Houghton, Michigan, United States
- Department of Mechanical Engineering and Engineering Mechanics, Michigan Technological University, Houghton, Michigan, United States
| |
Collapse
|
16
|
Yu Z, Chen Y, Li J, Chen C, Lu H, Chen S, Zhang T, Guo T, Zhu Y, Jin J, Yan S, Chen H. A tempo-spatial controllable microfluidic shear-stress generator for in-vitro mimicking of the thrombus. J Nanobiotechnology 2024; 22:187. [PMID: 38632623 PMCID: PMC11022418 DOI: 10.1186/s12951-024-02334-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 02/09/2024] [Indexed: 04/19/2024] Open
Abstract
Pathological conditions linked to shear stress have been identified in hematological diseases, cardiovascular diseases, and cancer. These conditions often exhibit significantly elevated shear stress levels, surpassing 1000 dyn/cm2 in severely stenotic arteries. Heightened shear stress can induce mechanical harm to endothelial cells, potentially leading to bleeding and fatal consequences. However, current technology still grapples with limitations, including inadequate flexibility in simulating bodily shear stress environments, limited range of shear stress generation, and spatial and temporal adaptability. Consequently, a comprehensive understanding of the mechanisms underlying the impact of shear stress on physiological and pathological conditions, like thrombosis, remains inadequate. To address these limitations, this study presents a microfluidic-based shear stress generation chip as a proposed solution. The chip achieves a substantial 929-fold variation in shear stress solely by adjusting the degree of constriction in branch channels after PDMS fabrication. Experiments demonstrated that a rapid increase in shear stress up to 1000 dyn/cm2 significantly detached 88.2% cells from the substrate. Long-term exposure (24 h) to shear stress levels below 8.3 dyn/cm2 did not significantly impact cell growth. Furthermore, cells exposed to shear stress levels equal to or greater than 8.3 dyn/cm2 exhibited significant alterations in aspect ratio and orientation, following a normal distribution. This microfluidic chip provides a reliable tool for investigating cellular responses to the wide-ranging shear stress existing in both physiological and pathological flow conditions.
Collapse
Affiliation(s)
- Zhihang Yu
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Yiqun Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Jingjing Li
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW, 2052, Australia
| | - Chang Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Huaxiu Lu
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Siyuan Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Tingting Zhang
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Tianruo Guo
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney, NSW, 2052, Australia
| | - Yonggang Zhu
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China
| | - Jing Jin
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China.
| | - Sheng Yan
- Institute for Advanced Study, Shenzhen University, Shenzhen, 518060, China.
| | - Huaying Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen, 518055, China.
| |
Collapse
|
17
|
Lai A, Hawke A, Mohammed M, Thurgood P, Concilia G, Peter K, Khoshmanesh K, Baratchi S. A microfluidic model to study the effects of arrhythmic flows on endothelial cells. LAB ON A CHIP 2024; 24:2347-2357. [PMID: 38576401 DOI: 10.1039/d3lc00834g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/06/2024]
Abstract
Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and an important contributor to morbidity and mortality. Endothelial dysfunction has been postulated to be an important contributing factor in cardiovascular events in patients with AF. However, how vascular endothelial cells respond to arrhythmic flow is not fully understood, mainly due to the limitation of current in vitro systems to mimic arrhythmic flow conditions. To address this limitation, we developed a microfluidic system to study the effect of arrhythmic flow on the mechanobiology of human aortic endothelial cells (HAECs). The system utilises a computer-controlled piezoelectric pump for generating arrhythmic flow with a unique ability to control the variability in both the frequency and amplitude of pulse waves. The flow rate is modulated to reflect physiological or pathophysiological shear stress levels on endothelial cells. This enabled us to systematically dissect the importance of variability in the frequency and amplitude of pulses and shear stress level on endothelial cell mechanobiology. Our results indicated that arrhythmic flow at physiological shear stress level promotes endothelial cell spreading and reduces the plasma membrane-to-cytoplasmic distribution of β-catenin. In contrast, arrhythmic flow at low and atherogenic shear stress levels does not promote endothelial cell spreading or redistribution of β-catenin. Interestingly, under both shear stress levels, arrhythmic flow induces inflammation by promoting monocyte adhesion via an increase in ICAM-1 expression. Collectively, our microfluidic system provides opportunities to study the effect of arrhythmic flows on vascular endothelial mechanobiology in a systematic and reproducible manner.
Collapse
Affiliation(s)
- Austin Lai
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria, Australia
- Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia.
| | - Adam Hawke
- School of Engineering, RMIT University, Melbourne, Victoria, Australia.
| | - Mokhaled Mohammed
- School of Engineering, RMIT University, Melbourne, Victoria, Australia.
| | - Peter Thurgood
- Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia.
- School of Engineering, RMIT University, Melbourne, Victoria, Australia.
| | | | - Karlheinz Peter
- Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia.
- Baker Department of Cardiometabolic Health, University of Melbourne, Melbourne, Victoria, Australia
| | - Khashayar Khoshmanesh
- Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia.
- School of Engineering, RMIT University, Melbourne, Victoria, Australia.
| | - Sara Baratchi
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria, Australia
- Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia.
- Baker Department of Cardiometabolic Health, University of Melbourne, Melbourne, Victoria, Australia
| |
Collapse
|
18
|
Kwak D, Im Y, Nam H, Nam U, Kim S, Kim W, Kim HJ, Park J, Jeon JS. Analyzing the effects of helical flow in blood vessels using acoustofluidic-based dynamic flow generator. Acta Biomater 2024; 177:216-227. [PMID: 38253303 DOI: 10.1016/j.actbio.2024.01.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 12/26/2023] [Accepted: 01/16/2024] [Indexed: 01/24/2024]
Abstract
The effects of helical flow in a blood vessel are investigated in a dynamic flow generator using surface acoustic wave (SAW) in the microfluidic device. The SAW, generated by an interdigital transducer (IDT), induces acoustic streaming, resulting in a stable and consistent helical flow pattern in microscale channels. This approach allows rapid development of helical flow within the channel without directly contacting the medium. The precise design of the window enables the creation of distinct unidirectional vortices, which can be controlled by adjusting the amplitude of the SAW. Within this device, optimal operational parameters of the dynamic flow generator to preserve the integrity of endothelial cells are found, and in such settings, the actin filaments within the cells are aligned to the desired state. Our findings reveal that intracellular Ca2+ concentrations vary in response to flow conditions. Specifically, comparable maximum intensity and graphical patterns were observed between low-flow rate helical flow and high-flow rate Hagen-Poiseuille flow. These suggest that the cells respond to the helical flow through mechanosensitive ion channels. Finally, adherence of monocytes is effectively reduced under helical flow conditions in an inflammatory environment, highlighting the atheroprotective role of helical flow. STATEMENT OF SIGNIFICANCE: Helical flow in blood vessels is well known to prevent atherosclerosis. However, despite efforts to replicate helical flow in microscale channels, there is still a lack of in vitro models which can generate helical flow for analyzing its effects on the vascular system. In this study, we developed a method for generating steady and constant helical flow in microfluidic channel using acoustofluidic techniques. By utilizing this dynamic flow generator, we were able to observe the atheroprotective aspects of helical flow in vitro, including the enhancement of calcium ion flux and reduction of monocyte adhesion. This study paves the way for an in vitro model of dynamic cell culture and offers advanced investigation into helical flow in our circulatory system.
Collapse
Affiliation(s)
- Daesik Kwak
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Yongtaek Im
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Hyeono Nam
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Ungsig Nam
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Seunggyu Kim
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Woohyuk Kim
- School of Mechanical Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Hyun Jin Kim
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Jinsoo Park
- School of Mechanical Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Jessie S Jeon
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea.
| |
Collapse
|
19
|
Chandurkar MK, Mittal N, Royer-Weeden SP, Lehmann SD, Rho Y, Han SJ. Low Shear in Short-Term Impacts Endothelial Cell Traction and Alignment in Long-Term. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2023.09.20.558732. [PMID: 37790318 PMCID: PMC10542130 DOI: 10.1101/2023.09.20.558732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/05/2023]
Abstract
Within the vascular system, endothelial cells (ECs) are exposed to fluid shear stress (FSS), a mechanical force exerted by blood flow that is critical for regulating cellular tension and maintaining vascular homeostasis. The way ECs react to FSS varies significantly; while high, laminar FSS supports vasodilation and suppresses inflammation, low or disturbed FSS can lead to endothelial dysfunction and increase the risk of cardiovascular diseases. Yet, the adaptation of ECs to dynamically varying FSS remains poorly understood. This study focuses on the dynamic responses of ECs to brief periods of low FSS, examining its impact on endothelial traction-a measure of cellular tension that plays a crucial role in how endothelial cells respond to mechanical stimuli. By integrating traction force microscopy (TFM) with a custom-built flow chamber, we analyzed how human umbilical vein endothelial cells (HUVECs) adjust their traction in response to shifts from low to high shear stress. We discovered that initial exposure to low FSS prompts a marked increase in traction force, which continues to rise over 10 hours before slowly decreasing. In contrast, immediate exposure to high FSS causes a quick spike in traction followed by a swift reduction, revealing distinct patterns of traction behavior under different shear conditions. Importantly, the direction of traction forces and the resulting cellular alignment under these conditions indicate that the initial shear experience dictates long-term endothelial behavior. Our findings shed light on the critical influence of short-lived low-shear stress experiences in shaping endothelial function, indicating that early exposure to low FSS results in enduring changes in endothelial contractility and alignment, with significant consequences for vascular health and the development of cardiovascular diseases.
Collapse
Affiliation(s)
- Mohanish K. Chandurkar
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931
- Health Research Institute, Michigan Technological University, Houghton, MI 49931
| | - Nikhil Mittal
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931
- Health Research Institute, Michigan Technological University, Houghton, MI 49931
| | - Shaina P. Royer-Weeden
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931
- Health Research Institute, Michigan Technological University, Houghton, MI 49931
| | - Steven D. Lehmann
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931
| | - Yeonwoo Rho
- Department of Mathematical Sciences, Michigan Technological University, Houghton, MI 49931
| | - Sangyoon J. Han
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931
- Health Research Institute, Michigan Technological University, Houghton, MI 49931
- Department of Mechanical Engineering and Engineering Mechanics, Michigan Technological University, Houghton, MI 49931
| |
Collapse
|
20
|
Lai A, Zhou Y, Thurgood P, Chheang C, Chandra Sekar N, Nguyen N, Peter K, Khoshmanesh K, Baratchi S. Endothelial Response to the Combined Biomechanics of Vessel Stiffness and Shear Stress Is Regulated via Piezo1. ACS APPLIED MATERIALS & INTERFACES 2023; 15:59103-59116. [PMID: 38073418 DOI: 10.1021/acsami.3c07756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2023]
Abstract
How endothelial cells sense and respond to dynamic changes in their biophysical surroundings as we age is not fully understood. Vascular stiffness is clearly a contributing factor not only in several cardiovascular diseases but also in physiological processes such as aging and vascular dementia. To address this gap, we utilized a microfluidic model to explore how substrate stiffness in the presence of shear stress affects endothelial morphology, senescence, proliferation, and inflammation. We also studied the role of mechanosensitive ion channel Piezo1 in endothelial responses under the combined effect of shear stress and substrate stiffness. To do so, we cultured endothelial cells inside microfluidic channels covered with fibronectin-coated elastomer with elastic moduli of 40 and 200 kPa, respectively, mimicking the stiffness of the vessel walls in young and aged arteries. The endothelial cells were exposed to atheroprotective and atherogenic shear stress levels of 10 and 2 dyn/cm2, respectively. Our findings show that substrate stiffness affects senescence under atheroprotective flow conditions and cytoskeleton remodeling, senescence, and inflammation under atherogenic flow conditions. Additionally, we found that the expression of Piezo1 plays a crucial role in endothelial adaptation to flow and regulation of inflammation under both atheroprotective and atherogenic shear stress levels. However, Piezo1 contribution to endothelial senescence was limited to the soft substrate and atheroprotective shear stress level. Overall, our study characterizes the response of endothelial cells to the combined effect of shear stress and substrate stiffness and reveals a previously unidentified role of Piezo1 in endothelial response to vessel stiffening, which potentially can be therapeutically targeted to alleviate endothelial dysfunction in aging adults.
Collapse
Affiliation(s)
- Austin Lai
- School of Health & Biomedical Sciences, RMIT University, Bundoora, Victoria 3082, Australia
- Baker Heart and Diabetes Institute, Melbourne, Victoria 3004, Australia
| | - Ying Zhou
- Baker Heart and Diabetes Institute, Melbourne, Victoria 3004, Australia
| | - Peter Thurgood
- Baker Heart and Diabetes Institute, Melbourne, Victoria 3004, Australia
- School of Engineering, RMIT University, Melbourne, Victoria 3000, Australia
| | - Chanly Chheang
- Baker Heart and Diabetes Institute, Melbourne, Victoria 3004, Australia
| | - Nadia Chandra Sekar
- School of Health & Biomedical Sciences, RMIT University, Bundoora, Victoria 3082, Australia
- Baker Heart and Diabetes Institute, Melbourne, Victoria 3004, Australia
| | - Ngan Nguyen
- School of Engineering, RMIT University, Melbourne, Victoria 3000, Australia
- Medical Technology Victoria, Swinburne University of Technology, Hawthorn, Victoria 3122, Australia
| | - Karlheinz Peter
- Baker Heart and Diabetes Institute, Melbourne, Victoria 3004, Australia
- Department of Cardiometabolic Health, The University of Melbourne, Parkville, Victoria 3010, Australia
| | - Khashayar Khoshmanesh
- Baker Heart and Diabetes Institute, Melbourne, Victoria 3004, Australia
- School of Engineering, RMIT University, Melbourne, Victoria 3000, Australia
| | - Sara Baratchi
- School of Health & Biomedical Sciences, RMIT University, Bundoora, Victoria 3082, Australia
- Baker Heart and Diabetes Institute, Melbourne, Victoria 3004, Australia
- Department of Cardiometabolic Health, The University of Melbourne, Parkville, Victoria 3010, Australia
| |
Collapse
|
21
|
Zhou HL, Jiang XZ, Ventikos Y. Role of blood flow in endothelial functionality: a review. Front Cell Dev Biol 2023; 11:1259280. [PMID: 37905167 PMCID: PMC10613523 DOI: 10.3389/fcell.2023.1259280] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2023] [Accepted: 10/04/2023] [Indexed: 11/02/2023] Open
Abstract
Endothelial cells, located on the surface of blood vessel walls, are constantly stimulated by mechanical forces from the blood flow. The mechanical forces, i.e., fluid shear stress, induced by the blood flow play a pivotal role in controlling multiple physiological processes at the endothelium and in regulating various pathways that maintain homeostasis and vascular function. In this review, research looking at different blood fluid patterns and fluid shear stress in the circulation system is summarized, together with the interactions between the blood flow and the endothelial cells. This review also highlights the flow profile as a response to the configurational changes of the endothelial glycocalyx, which is less revisited in previous reviews. The role of endothelial glycocalyx in maintaining endothelium health and the strategies for the restoration of damaged endothelial glycocalyx are discussed from the perspective of the fluid shear stress. This review provides a new perspective regarding our understanding of the role that blood flow plays in regulating endothelial functionality.
Collapse
Affiliation(s)
- Hui Lin Zhou
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| | - Xi Zhuo Jiang
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| | - Yiannis Ventikos
- Department of Mechanical Engineering, Monash University, Melbourne, VIC, Australia
| |
Collapse
|
22
|
Tong CY, Li HZ, Derek CJC. A microscale system for in situ investigation of immobilized microalgal cell resistance against liquid flow in the early inoculation stage. LAB ON A CHIP 2023; 23:4052-4066. [PMID: 37609763 DOI: 10.1039/d3lc00415e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
In attached microalgae cultivation systems, cell detachment due to fluid hydrodynamic flow is not a subject matter that is commonly looked into. However, this phenomenon is of great relevance to optimizing the operating parameters of algae cultivation and feasible reactor design. Hence, this current work miniaturizes traditional benchtop assays into a microfluidic platform to study the cell detachment of green microalgae, Chlorella vulgaris, from porous substrates during its early cultivation stage under precisely controlled conditions. As revealed by time lapse microscopy, an increase in bulk flow velocity facilitated nutrient transport but also triggered cell detachment events. At a flow rate of 1000 μL min-1 of growth medium for 120 min, the algal cell coverage was up to 5% lower than those at 5 μL min-1 and 50 μL min-1. In static seeding, the evolution of attached cell resistance toward liquid flows was dependent on hydrodynamic zones. The center zone of the microchannel was shown to be a "comfortable zone" of the attached cells to sequester nutrients effectively at lower medium flow rates but there was a profile transition where outlet zones favored cell attachment the most at higher flow rates (1.13 times higher than the center zone for 1000 μL min-1). Besides, computational fluid dynamics (CFD) simulations illustrated that the focusing band varied between cross-sections and depths, while the streamline was the least concentrated along the side walls and bottom plane of the microfluidic devices. It was intriguing to learn that cell detachment was not primarily happening along the symmetry streamline. Insight gained from this study could be further applied in the optimization of operating conditions of attached cultivation systems whilst preserving laminar flow conditions.
Collapse
Affiliation(s)
- C Y Tong
- School of Chemical Engineering, Universiti Sains Malaysia, Engineering Campus, 14300 Nibong Tebal, Penang, Malaysia.
- Laboratory of Reactions and Process Engineering, University of Lorraine, CNRS, 1, rue Grandville, BP 20451, 54001 Nancy Cedex, France.
| | - Huai Z Li
- Laboratory of Reactions and Process Engineering, University of Lorraine, CNRS, 1, rue Grandville, BP 20451, 54001 Nancy Cedex, France.
| | - C J C Derek
- School of Chemical Engineering, Universiti Sains Malaysia, Engineering Campus, 14300 Nibong Tebal, Penang, Malaysia.
| |
Collapse
|
23
|
Rojas-González DM, Babendreyer A, Ludwig A, Mela P. Analysis of flow-induced transcriptional response and cell alignment of different sources of endothelial cells used in vascular tissue engineering. Sci Rep 2023; 13:14384. [PMID: 37658092 PMCID: PMC10474151 DOI: 10.1038/s41598-023-41247-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Accepted: 08/23/2023] [Indexed: 09/03/2023] Open
Abstract
Endothelialization of tissue-engineered vascular grafts has proven crucial for implant functionality and thus clinical outcome, however, the choice of endothelial cells (ECs) is often driven by availability rather than by the type of vessel to be replaced. In this work we studied the response to flow of different human ECs with the aim of examining whether their response in vitro is dictated by their original in vivo conditions. Arterial, venous, and microvascular ECs were cultured under shear stress (SS) of 0, 0.3, 3, 1, 10, and 30 dyne/cm2 for 24 h. Regulation of flow-induced marker KLF2 was similar across the different ECs. Upregulation of anti-thrombotic markers, TM and TPA, was mainly seen at higher SS. Cell elongation and alignment was observed for the different ECs at 10 and 30 dyne/cm2 while at lower SS cells maintained a random orientation. Downregulation of pro-inflammatory factors SELE, IL8, and VCAM1 and up-regulation of anti-oxidant markers NQO1 and HO1 was present even at SS for which cell alignment was not observed. Our results evidenced similarities in the response to flow among the different ECs, suggesting that the maintenance of the resting state in vitro is not dictated by the SS typical of the tissue of origin and that absence of flow-induced cell orientation does not necessarily correlate with a pro-inflammatory state of the ECs. These results support the use of ECs from easily accessible sources for in vitro vascular tissue engineering independently from the target vessel.
Collapse
Affiliation(s)
- Diana M Rojas-González
- Department of Biohybrid & Medical Textiles (BioTex) at Center of Biohybrid Medical Systems (CBMS), AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany
- Chair of Medical Materials and Implants, Department of Mechanical Engineering, School of Engineering and Design and Munich Institute of Biomedical Engineering, Technical University of Munich, Boltzmannstr 15, 85748, Garching, Germany
| | - Aaron Babendreyer
- Institute of Molecular Pharmacology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, 52074, Aachen, Germany.
| | - Andreas Ludwig
- Institute of Molecular Pharmacology, Medical Faculty, RWTH Aachen University, Pauwelsstr. 30, 52074, Aachen, Germany
| | - Petra Mela
- Department of Biohybrid & Medical Textiles (BioTex) at Center of Biohybrid Medical Systems (CBMS), AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Forckenbeckstr. 55, 52074, Aachen, Germany.
- Chair of Medical Materials and Implants, Department of Mechanical Engineering, School of Engineering and Design and Munich Institute of Biomedical Engineering, Technical University of Munich, Boltzmannstr 15, 85748, Garching, Germany.
| |
Collapse
|
24
|
Raj M K, Priyadarshani J, Karan P, Bandyopadhyay S, Bhattacharya S, Chakraborty S. Bio-inspired microfluidics: A review. BIOMICROFLUIDICS 2023; 17:051503. [PMID: 37781135 PMCID: PMC10539033 DOI: 10.1063/5.0161809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 09/01/2023] [Indexed: 10/03/2023]
Abstract
Biomicrofluidics, a subdomain of microfluidics, has been inspired by several ideas from nature. However, while the basic inspiration for the same may be drawn from the living world, the translation of all relevant essential functionalities to an artificially engineered framework does not remain trivial. Here, we review the recent progress in bio-inspired microfluidic systems via harnessing the integration of experimental and simulation tools delving into the interface of engineering and biology. Development of "on-chip" technologies as well as their multifarious applications is subsequently discussed, accompanying the relevant advancements in materials and fabrication technology. Pointers toward new directions in research, including an amalgamated fusion of data-driven modeling (such as artificial intelligence and machine learning) and physics-based paradigm, to come up with a human physiological replica on a synthetic bio-chip with due accounting of personalized features, are suggested. These are likely to facilitate physiologically replicating disease modeling on an artificially engineered biochip as well as advance drug development and screening in an expedited route with the minimization of animal and human trials.
Collapse
Affiliation(s)
- Kiran Raj M
- Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu 600036, India
| | - Jyotsana Priyadarshani
- Department of Mechanical Engineering, Biomechanics Section (BMe), KU Leuven, Celestijnenlaan 300, 3001 Louvain, Belgium
| | - Pratyaksh Karan
- Géosciences Rennes Univ Rennes, CNRS, Géosciences Rennes, UMR 6118, 35000 Rennes, France
| | - Saumyadwip Bandyopadhyay
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302, India
| | - Soumya Bhattacharya
- Achira Labs Private Limited, 66b, 13th Cross Rd., Dollar Layout, 3–Phase, JP Nagar, Bangalore, Karnataka 560078, India
| | - Suman Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302, India
| |
Collapse
|
25
|
Cauli E, Polidoro MA, Marzorati S, Bernardi C, Rasponi M, Lleo A. Cancer-on-chip: a 3D model for the study of the tumor microenvironment. J Biol Eng 2023; 17:53. [PMID: 37592292 PMCID: PMC10436436 DOI: 10.1186/s13036-023-00372-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 08/03/2023] [Indexed: 08/19/2023] Open
Abstract
The approval of anticancer therapeutic strategies is still slowed down by the lack of models able to faithfully reproduce in vivo cancer physiology. On one hand, the conventional in vitro models fail to recapitulate the organ and tissue structures, the fluid flows, and the mechanical stimuli characterizing the human body compartments. On the other hand, in vivo animal models cannot reproduce the typical human tumor microenvironment, essential to study cancer behavior and progression. This study reviews the cancer-on-chips as one of the most promising tools to model and investigate the tumor microenvironment and metastasis. We also described how cancer-on-chip devices have been developed and implemented to study the most common primary cancers and their metastatic sites. Pros and cons of this technology are then discussed highlighting the future challenges to close the gap between the pre-clinical and clinical studies and accelerate the approval of new anticancer therapies in humans.
Collapse
Affiliation(s)
- Elisa Cauli
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy.
- Accelera Srl, Nerviano, Milan, Italy.
| | - Michela Anna Polidoro
- Hepatobiliary Immunopathology Laboratory, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Simona Marzorati
- Hepatobiliary Immunopathology Laboratory, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| | | | - Marco Rasponi
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy
| | - Ana Lleo
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
- Division of Internal Medicine and Hepatology, Department of Gastroenterology, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| |
Collapse
|
26
|
Cui J, Jiang W, Su J, Zhang J, Yu Y, Ding Y. Microfluidic-to-macrofluidic: A simple in vitro model of atherosclerosis induced by fluidic stimulation. BIOMICROFLUIDICS 2023; 17:044106. [PMID: 37662690 PMCID: PMC10468215 DOI: 10.1063/5.0155267] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Accepted: 08/08/2023] [Indexed: 09/05/2023]
Abstract
Atherosclerosis is the narrowing of the arteries due to the formation of fatty plaques, which is the main cause of myocardial infarction and stroke. It is important to develop an in vitro model that can combine multiple-type cell co-culture, vessel wall-like structure, and fluid condition to simulate the processes of atherosclerosis. Herein, we used a simple microfluidic chip made of three polydimethylsiloxane layers to co-culture endothelial and smooth muscle cells in a flat rectangular microchannel. After being connected with a circulating culture medium driven by a peristaltic pump, the flat microchannel was deformed to a tunnel-like macrochannel. The fluid pressure and shear stress applied on the cells in the deformed macrochannel can be varied by adjusting the circulating flow rate and the thickness of the middle layer. Under three levels of the pressure (65, 131, and 196 mm Hg) or shear stress (0.99, 4.78, and 24 dyne/cm2) conditions, a series of atherosclerosis-related events, including endothelial cell junction, pro-inflammatory cytokine secretion, monocyte adhesion, and lipid accumulation, were investigated. The atherosclerosis-related results showed that the medium pressure or shear stress exhibited a relatively weak pro-atherosclerotic effect in a V-shaped trend. To demonstrate the potential in drug screen, the effects of three well-known anti-atherosclerotic drugs (atorvastatin, tetramethylpyrazine, and high-density lipoprotein) on the lipid accumulation and pro-inflammatory cytokine secretion were evaluated under a strong pro-atherosclerotic fluid condition (65 mm Hg, 0.99 dyne/cm2). This in vitro model of atherosclerosis has shown great potential in drug screen application.
Collapse
Affiliation(s)
- Jingang Cui
- College of Life Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wei Jiang
- College of Life Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jilei Su
- College of Life Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jiazhen Zhang
- College of Life Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yongliang Yu
- School of Engineering Science, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yongsheng Ding
- College of Life Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
27
|
Banerjee P, Rosales JE, Chau K, Nguyen MTH, Kotla S, Lin SH, Deswal A, Dantzer R, Olmsted-Davis EA, Nguyen H, Wang G, Cooke JP, Abe JI, Le NT. Possible molecular mechanisms underlying the development of atherosclerosis in cancer survivors. Front Cardiovasc Med 2023; 10:1186679. [PMID: 37332576 PMCID: PMC10272458 DOI: 10.3389/fcvm.2023.1186679] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 05/17/2023] [Indexed: 06/20/2023] Open
Abstract
Cancer survivors undergone treatment face an increased risk of developing atherosclerotic cardiovascular disease (CVD), yet the underlying mechanisms remain elusive. Recent studies have revealed that chemotherapy can drive senescent cancer cells to acquire a proliferative phenotype known as senescence-associated stemness (SAS). These SAS cells exhibit enhanced growth and resistance to cancer treatment, thereby contributing to disease progression. Endothelial cell (EC) senescence has been implicated in atherosclerosis and cancer, including among cancer survivors. Treatment modalities for cancer can induce EC senescence, leading to the development of SAS phenotype and subsequent atherosclerosis in cancer survivors. Consequently, targeting senescent ECs displaying the SAS phenotype hold promise as a therapeutic approach for managing atherosclerotic CVD in this population. This review aims to provide a mechanistic understanding of SAS induction in ECs and its contribution to atherosclerosis among cancer survivors. We delve into the mechanisms underlying EC senescence in response to disturbed flow and ionizing radiation, which play pivotal role in atherosclerosis and cancer. Key pathways, including p90RSK/TERF2IP, TGFβR1/SMAD, and BH4 signaling are explored as potential targets for cancer treatment. By comprehending the similarities and distinctions between different types of senescence and the associated pathways, we can pave the way for targeted interventions aim at enhancing the cardiovascular health of this vulnerable population. The insights gained from this review may facilitate the development of novel therapeutic strategies for managing atherosclerotic CVD in cancer survivors.
Collapse
Affiliation(s)
- Priyanka Banerjee
- Center for Cardiovascular Regeneration, Department of Cardiovascular Sciences, Houston Methodist Research Institute, Houston, TX, United States
| | - Julia Enterría Rosales
- Department of Cardiology, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
- School of Medicine, Instituto Tecnológico de Monterrey, Guadalajara, Mexico
| | - Khanh Chau
- Center for Cardiovascular Regeneration, Department of Cardiovascular Sciences, Houston Methodist Research Institute, Houston, TX, United States
| | - Minh T. H. Nguyen
- Center for Cardiovascular Regeneration, Department of Cardiovascular Sciences, Houston Methodist Research Institute, Houston, TX, United States
- Department of Life Science, University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology, Hanoi, Vietnam
| | - Sivareddy Kotla
- Department of Cardiology, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Steven H. Lin
- Department of Cardiology, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Anita Deswal
- Department of Cardiology, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Robert Dantzer
- Department of Symptom Research, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Elizabeth A. Olmsted-Davis
- Center for Cardiovascular Regeneration, Department of Cardiovascular Sciences, Houston Methodist Research Institute, Houston, TX, United States
| | - Hung Nguyen
- Cancer Division, Burnett School of Biomedical Science, College of Medicine, University of Central Florida, Orlando, FL, United States
| | - Guangyu Wang
- Center for Cardiovascular Regeneration, Department of Cardiovascular Sciences, Houston Methodist Research Institute, Houston, TX, United States
| | - John P. Cooke
- Center for Cardiovascular Regeneration, Department of Cardiovascular Sciences, Houston Methodist Research Institute, Houston, TX, United States
| | - Jun-ichi Abe
- Department of Cardiology, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Nhat-Tu Le
- Center for Cardiovascular Regeneration, Department of Cardiovascular Sciences, Houston Methodist Research Institute, Houston, TX, United States
| |
Collapse
|
28
|
Kang JH, Jang M, Seo SJ, Choi A, Shin D, Seo S, Lee SH, Kim HN. Mechanobiological Adaptation to Hyperosmolarity Enhances Barrier Function in Human Vascular Microphysiological System. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2206384. [PMID: 36808839 PMCID: PMC10161024 DOI: 10.1002/advs.202206384] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 01/27/2023] [Indexed: 05/06/2023]
Abstract
In infectious disease such as sepsis and COVID-19, blood vessel leakage treatment is critical to prevent fatal progression into multi-organ failure and ultimately death, but the existing effective therapeutic modalities that improve vascular barrier function are limited. Here, this study reports that osmolarity modulation can significantly improve vascular barrier function, even in an inflammatory condition. 3D human vascular microphysiological systems and automated permeability quantification processes for high-throughput analysis of vascular barrier function are utilized. Vascular barrier function is enhanced by >7-folds with 24-48 h hyperosmotic exposure (time window of emergency care; >500 mOsm L-1 ) but is disrupted after hypo-osmotic exposure (<200 mOsm L-1 ). By integrating genetic and protein level analysis, it is shown that hyperosmolarity upregulates vascular endothelial-cadherin, cortical F-actin, and cell-cell junction tension, indicating that hyperosmotic adaptation mechanically stabilizes the vascular barrier. Importantly, improved vascular barrier function following hyperosmotic exposure is maintained even after chronic exposure to proinflammatory cytokines and iso-osmotic recovery via Yes-associated protein signaling pathways. This study suggests that osmolarity modulation may be a unique therapeutic strategy to proactively prevent infectious disease progression into severe stages via vascular barrier function protection.
Collapse
Affiliation(s)
- Joon Ho Kang
- Brain Science InstituteKorea Institute of Science and TechnologySeoul02792Republic of Korea
| | - Minjeong Jang
- Brain Science InstituteKorea Institute of Science and TechnologySeoul02792Republic of Korea
| | - Su Jin Seo
- Brain Science InstituteKorea Institute of Science and TechnologySeoul02792Republic of Korea
- Department of Chemical EngineeringKwangwoon UniversitySeoul01897Republic of Korea
| | - Andrew Choi
- Brain Science InstituteKorea Institute of Science and TechnologySeoul02792Republic of Korea
| | - Daeeun Shin
- Brain Science InstituteKorea Institute of Science and TechnologySeoul02792Republic of Korea
- School of Mechanical EngineeringSungkyunkwan UniversitySuwon16419Republic of Korea
| | - Suyoung Seo
- Brain Science InstituteKorea Institute of Science and TechnologySeoul02792Republic of Korea
- Program in Nano Science and TechnologyGraduate School of Convergence Science and TechnologySeoul National UniversitySeoul08826Republic of Korea
| | - Soo Hyun Lee
- Brain Science InstituteKorea Institute of Science and TechnologySeoul02792Republic of Korea
- Division of Bio‐Medical Science & TechnologyKIST SchoolUniversity of Science and Technology (UST)Seoul02792Republic of Korea
| | - Hong Nam Kim
- Brain Science InstituteKorea Institute of Science and TechnologySeoul02792Republic of Korea
- Division of Bio‐Medical Science & TechnologyKIST SchoolUniversity of Science and Technology (UST)Seoul02792Republic of Korea
- School of Mechanical EngineeringYonsei UniversitySeoul03722Republic of Korea
- Yonsei‐KIST Convergence Research InstituteYonsei UniversitySeoul03722Republic of Korea
| |
Collapse
|
29
|
Sunildutt N, Parihar P, Chethikkattuveli Salih AR, Lee SH, Choi KH. Revolutionizing drug development: harnessing the potential of organ-on-chip technology for disease modeling and drug discovery. Front Pharmacol 2023; 14:1139229. [PMID: 37180709 PMCID: PMC10166826 DOI: 10.3389/fphar.2023.1139229] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Accepted: 04/05/2023] [Indexed: 05/16/2023] Open
Abstract
The inefficiency of existing animal models to precisely predict human pharmacological effects is the root reason for drug development failure. Microphysiological system/organ-on-a-chip technology (organ-on-a-chip platform) is a microfluidic device cultured with human living cells under specific organ shear stress which can faithfully replicate human organ-body level pathophysiology. This emerging organ-on-chip platform can be a remarkable alternative for animal models with a broad range of purposes in drug testing and precision medicine. Here, we review the parameters employed in using organ on chip platform as a plot mimic diseases, genetic disorders, drug toxicity effects in different organs, biomarker identification, and drug discoveries. Additionally, we address the current challenges of the organ-on-chip platform that should be overcome to be accepted by drug regulatory agencies and pharmaceutical industries. Moreover, we highlight the future direction of the organ-on-chip platform parameters for enhancing and accelerating drug discoveries and personalized medicine.
Collapse
Affiliation(s)
- Naina Sunildutt
- Department of Mechatronics Engineering, Jeju National University, Jeju, Republic of Korea
| | - Pratibha Parihar
- Department of Mechatronics Engineering, Jeju National University, Jeju, Republic of Korea
| | | | - Sang Ho Lee
- College of Pharmacy, Jeju National University, Jeju, Republic of Korea
| | - Kyung Hyun Choi
- Department of Mechatronics Engineering, Jeju National University, Jeju, Republic of Korea
| |
Collapse
|
30
|
Abstract
Cardiovascular diseases are a group of heart and blood vessel disorders which remain a leading cause of morbidity and mortality worldwide. Currently, cardiovascular disease research commonly depends on in vivo rodent models and in vitro human cell culture models. Despite their widespread use in cardiovascular disease research, there are some long-standing limitations: animal models often fail to faithfully mimic human response, while traditional cell models ignore the in vivo microenvironment, intercellular communications, and tissue-tissue interactions. The convergence of microfabrication and tissue engineering has given rise to organ-on-a-chip technologies. The organ-on-a-chip is a microdevice containing microfluidic chips, cells, and extracellular matrix to reproduce the physiological processes of a certain part of the human body, and is nowadays considered a promising bridge between in vivo models and in vitro 2D or 3D cell culture models. Considering the difficulty in obtaining human vessel and heart samples, the development of vessel-on-a-chip and heart-on-a-chip systems can guide cardiovascular disease research in the future. In this review, we elaborate methods and materials to fabricate organ-on-a-chip systems and summarize the construction of vessel and heart chips. The construction of vessels-on-a-chip must consider the cyclic mechanical stretch and fluid shear stress, while hemodynamic forces and cardiomyocyte maturation are key factors in building hearts-on-a-chip. We also introduce the application of organs-on-a-chip in cardiovascular disease study.
Collapse
|
31
|
Thurgood P, Needham S, Pirogova E, Peter K, Baratchi S, Khoshmanesh K. Dynamic Vortex Generation, Pulsed Injection, and Rapid Mixing of Blood Samples in Microfluidics Using the Tube Oscillation Mechanism. Anal Chem 2023; 95:3089-3097. [PMID: 36692453 DOI: 10.1021/acs.analchem.2c05456] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Here, we describe the generation of dynamic vortices in micro-scale cavities at low flow rates. The system utilizes a computer-controlled audio speaker to axially oscillate the inlet tube of the microfluidic system at desired frequencies and amplitudes. The oscillation of the tube induces transiently high flow rates in the system, which facilitates the generation of dynamic vortices inside the cavity. The size of the vortices can be modulated by varying the tube oscillation frequency or amplitude. The vortices can be generated in single or serial cavities and in a wide range of cavity sizes. We demonstrate the suitability of the tube oscillation mechanism for the pulsed injection of water-based solutions or whole blood into the cavity. The injection rate can be controlled by the oscillation characteristics of the tube, enabling the injection of liquids at ultralow flow rates. The dynamic vortices facilitate the rapid mixing of the injected liquid with the main flow. The controllability and versatility of this technology allow for the development of programmable inertial microfluidic systems for performing multistep biological assays.
Collapse
Affiliation(s)
- Peter Thurgood
- School of Engineering, RMIT University, Melbourne, Victoria3001, Australia
| | - Scott Needham
- Leading Technology Group, Camberwell, Victoria3124, Australia
| | - Elena Pirogova
- School of Engineering, RMIT University, Melbourne, Victoria3001, Australia
| | - Karlheinz Peter
- Baker Heart and Diabetes Institute, Melbourne, Victoria3004, Australia.,Department of Cardiometabolic Health, University of Melbourne, Parkville, Victoria3052, Australia
| | - Sara Baratchi
- School of Health & Biomedical Sciences, RMIT University, Bundoora, Victoria3082, Australia
| | | |
Collapse
|
32
|
Chandra Sekar N, Aguilera Suarez S, Nguyen N, Lai A, Thurgood P, Zhou Y, Chheang C, Needham S, Pirogova E, Peter K, Khoshmanesh K, Baratchi S. Studying the Synergistic Effect of Substrate Stiffness and Cyclic Stretch Level on Endothelial Cells Using an Elastomeric Cell Culture Chamber. ACS APPLIED MATERIALS & INTERFACES 2023; 15:4863-4872. [PMID: 36652631 DOI: 10.1021/acsami.2c15818] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Endothelial cells lining blood vessels are continuously exposed to biophysical cues that regulate their function in health and disease. As we age, blood vessels lose their elasticity and become stiffer. Vessel stiffness alters the mechanical forces that endothelial cells experience. Despite ample evidence on the contribution of endothelial cells to vessel stiffness, less is known about how vessel stiffness affects endothelial cells. In this study, we developed a versatile model to study the cooperative effect of substrate stiffness and cyclic stretch on human aortic endothelial cells. We cultured endothelial cells on elastomeric wells covered with fibronectin-coated polyacrylamide gel. Varying the concentrations of acrylamide and bis-acrylamide enabled us to produce soft and stiff substrates with elastic modules of 40 and 200 kPa, respectively. Using a customized three-dimensional (3D) printed cam-driven system, the cells were exposed to 5 and 10% cyclic stretch levels. This enabled us to mimic the stiffness and stretch levels that endothelial cells experience in young and aged arteries. Using this model, we found that endothelial cells cultured on a soft substrate had minimal cytoskeletal alignment to the direction of the stretch compared to the ones cultured on the stiff substrate. We also observed an increase in the cellular area and aspect ratio in cells cultured on the stiff substrate, both of which are positively regulated by cyclic stretch. However, neither cyclic stretch nor substrate stiffness significantly affected the nuclear circularity. Additionally, we found that the accumulation of NF-κB in the nucleus, endothelial proliferation, tube formation, and expression of IL1β depends on the stretch level and substrate stiffness. Our model can be further used to investigate the complex signaling pathways associated with vessel stiffening that govern the endothelial responses to mechanical forces.
Collapse
Affiliation(s)
- Nadia Chandra Sekar
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria3082, Australia
| | | | - Ngan Nguyen
- School of Engineering, RMIT University, Melbourne, Victoria3000, Australia
| | - Austin Lai
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria3082, Australia
| | - Peter Thurgood
- School of Engineering, RMIT University, Melbourne, Victoria3000, Australia
| | - Ying Zhou
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria3082, Australia
| | - Chanly Chheang
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria3082, Australia
| | - Scott Needham
- Leading Technology Group, Kew, Victoria3101, Australia
| | - Elena Pirogova
- School of Engineering, RMIT University, Melbourne, Victoria3000, Australia
| | - Karlheinz Peter
- Baker Heart and Diabetes Institute, Melbourne, Victoria3004, Australia
- Department of Cardiometabolic Health, The University of Melbourne, Parkville, Victoria3010, Australia
| | | | - Sara Baratchi
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Victoria3082, Australia
- Baker Heart and Diabetes Institute, Melbourne, Victoria3004, Australia
- Department of Cardiometabolic Health, The University of Melbourne, Parkville, Victoria3010, Australia
| |
Collapse
|
33
|
Abdelkarim M, Perez-Davalos L, Abdelkader Y, Abostait A, Labouta HI. Critical design parameters to develop biomimetic organ-on-a-chip models for the evaluation of the safety and efficacy of nanoparticles. Expert Opin Drug Deliv 2023; 20:13-30. [PMID: 36440475 DOI: 10.1080/17425247.2023.2152000] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Organ-on-a-chip (OOC) models are based on microfluidics and can recapitulate the healthy and diseased microstructure of organs1 and tissues and the dynamic microenvironment inside the human body. However, the use of OOC models to evaluate the safety and efficacy of nanoparticles (NPs) is still in the early stages. AREAS COVERED The different design parameters of the microfluidic chip and the mechanical forces generated by fluid flow play a pivotal role in simulating the human environment. This review discusses the role of different key parameters on the performance of OOC models. These include the flow pattern, flow rate, shear stress (magnitude, rate, and distribution), viscosity of the media, and the microchannel dimensions and shape. We also discuss how the shear stress and other mechanical forces affect the transport of NPs across biological barriers, cell uptake, and their biocompatibility. EXPERT OPINION We describe several good practices and design parameters to consider for future OOC research. We submit that following these recommendations will help realize the full potential of the OOC models in the preclinical evaluation of novel therapies, including NPs.
Collapse
Affiliation(s)
- Mahmoud Abdelkarim
- Biomedical Engineering, University of Manitoba, R3T 5V6, Winnipeg, Manitoba, Canada.,College of Pharmacy, University of Manitoba, R3E 0T5, Winnipeg, Manitoba, Canada
| | - Luis Perez-Davalos
- College of Pharmacy, University of Manitoba, R3E 0T5, Winnipeg, Manitoba, Canada
| | - Yasmin Abdelkader
- College of Pharmacy, University of Manitoba, R3E 0T5, Winnipeg, Manitoba, Canada.,Department of Cell Biology, Biotechnology Research Institute, National Research Centre, 12622, Cairo, Egypt
| | - Amr Abostait
- College of Pharmacy, University of Manitoba, R3E 0T5, Winnipeg, Manitoba, Canada
| | - Hagar I Labouta
- Biomedical Engineering, University of Manitoba, R3T 5V6, Winnipeg, Manitoba, Canada.,College of Pharmacy, University of Manitoba, R3E 0T5, Winnipeg, Manitoba, Canada.,Children's Hospital Research Institute of Manitoba, R3E 3P4, Winnipeg, Manitoba, Canada.,Faculty of Pharmacy, Alexandria University, 21521, Alexandria, Egypt
| |
Collapse
|
34
|
Wu Y, Zhou Y, Paul R, Qin X, Islam K, Liu Y. Adaptable Microfluidic Vessel-on-a-Chip Platform for Investigating Tumor Metastatic Transport in Bloodstream. Anal Chem 2022; 94:12159-12166. [PMID: 35998619 DOI: 10.1021/acs.analchem.2c02556] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Cancer metastasis counts for 90% of cancer fatalities, and its development process is still a mystery. The dynamic process of tumor metastatic transport in the blood vessel is not well understood, in which some biomechanical factors, such as shear stress and various flow patterns, may have significant impacts. Here, we report a microfluidic vessel-on-a-chip platform for recapitulating several key metastatic steps of tumor cells in blood vessels on the same chip, including intravasation, circulating tumor cell (CTC) vascular adhesion, and extravasation. Due to its excellent adaptability, our system can reproduce various microenvironments to investigate the specific interactions between CTCs and blood vessels. On the basis of this platform, effects of important biomechanical factors on CTC adhesion such as vascular surface properties and vessel geometry-dependent hemodynamics were specifically inspected. We demonstrated that CTC adhesion is more likely to occur under certain mechano-physiological situations, such as vessels with vascular glycocalyx (VGCX) shedding and hemodynamic disturbances. Finally, computational models of both the fluidic dynamics in vessels and CTC adhesion were established based on the confocal scanned 3D images. The modeling results are believed to provide insights into exploring tumor metastasis progression and inspire new ideas for anticancer therapy development.
Collapse
Affiliation(s)
- Yue Wu
- Department of Bioengineering, Lehigh University, Bethlehem, Pennsylvania 18015, United States
| | - Yuyuan Zhou
- Department of Bioengineering, Lehigh University, Bethlehem, Pennsylvania 18015, United States
| | - Ratul Paul
- Department of Mechanical Engineering and Mechanics, Lehigh University, Bethlehem, Pennsylvania 18015, United States
| | - Xiaochen Qin
- Department of Bioengineering, Lehigh University, Bethlehem, Pennsylvania 18015, United States
| | - Khayrul Islam
- Department of Mechanical Engineering and Mechanics, Lehigh University, Bethlehem, Pennsylvania 18015, United States
| | - Yaling Liu
- Department of Bioengineering, Lehigh University, Bethlehem, Pennsylvania 18015, United States.,Department of Mechanical Engineering and Mechanics, Lehigh University, Bethlehem, Pennsylvania 18015, United States
| |
Collapse
|
35
|
Abello J, Raghavan S, Yien YY, Stratman AN. Peristaltic pumps adapted for laminar flow experiments enhance in vitro modeling of vascular cell behavior. J Biol Chem 2022; 298:102404. [PMID: 35988646 PMCID: PMC9508572 DOI: 10.1016/j.jbc.2022.102404] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 08/11/2022] [Accepted: 08/12/2022] [Indexed: 11/06/2022] Open
Abstract
Endothelial cells (ECs) are the primary cellular constituent of blood vessels that are in direct contact with hemodynamic forces over their lifetime. Throughout the body, vessels experience different blood flow patterns and rates that alter vascular architecture and cellular behavior. Because of the complexities of studying blood flow in an intact organism, particularly during development, the field has increasingly relied on in vitro modeling of blood flow as a powerful technique for studying hemodynamic-dependent signaling mechanisms in ECs. While commercial flow systems that recirculate fluids exist, many commercially available pumps are peristaltic and best model pulsatile flow conditions. However, there are many important situations in which ECs experience laminar flow conditions in vivo, such as along long straight stretches of the vasculature. To understand EC function under these contexts, it is important to be able to reproducibly model laminar flow conditions in vitro. Here, we outline a method to reliably adapt commercially available peristaltic pumps to study laminar flow conditions. Our proof-of-concept study focuses on 2D models but could be further adapted to 3D environments to better model in vivo scenarios, such as organ development. Our studies make significant inroads into solving technical challenges associated with flow modeling and allow us to conduct functional studies toward understanding the mechanistic role of shear forces on vascular architecture, cellular behavior, and remodeling in diverse physiological contexts.
Collapse
Affiliation(s)
- Javier Abello
- Department of Cell Biology and Physiology, Washington University in St. Louis School of Medicine, St. Louis, MO 63110
| | - Shreya Raghavan
- Department of Biomedical Engineering, Texas A&M University, College Station TX 77843
| | - Yvette Y Yien
- Pittsburgh Heart, Lung and Blood Vascular Medicine Institute and Department of Medicine, University of Pittsburgh, Pittsburgh, PA 15261
| | - Amber N Stratman
- Department of Cell Biology and Physiology, Washington University in St. Louis School of Medicine, St. Louis, MO 63110.
| |
Collapse
|
36
|
Jiang H, Li L, Zhang L, Zang G, Sun Z, Wang Z. Role of endothelial cells in vascular calcification. Front Cardiovasc Med 2022; 9:895005. [PMID: 35928939 PMCID: PMC9343736 DOI: 10.3389/fcvm.2022.895005] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Accepted: 06/28/2022] [Indexed: 11/13/2022] Open
Abstract
Vascular calcification (VC) is active and regulates extraosseous ossification progress, which is an independent predictor of cardiovascular disease (CVD) morbidity and mortality. Endothelial cells (ECs) line the innermost layer of blood vessels and directly respond to changes in flow shear stress and blood composition. Together with vascular smooth muscle cells, ECs maintain vascular homeostasis. Increased evidence shows that ECs have irreplaceable roles in VC due to their high plasticity. Endothelial progenitor cells, oxidative stress, inflammation, autocrine and paracrine functions, mechanotransduction, endothelial-to-mesenchymal transition (EndMT), and other factors prompt ECs to participate in VC. EndMT is a dedifferentiation process by which ECs lose their cell lineage and acquire other cell lineages; this progress coexists in both embryonic development and CVD. EndMT is regulated by several signaling molecules and transcription factors and ultimately mediates VC via osteogenic differentiation. The specific molecular mechanism of EndMT remains unclear. Can EndMT be reversed to treat VC? To address this and other questions, this study reviews the pathogenesis and research progress of VC, expounds the role of ECs in VC, and focuses on the regulatory factors underlying EndMT, with a view to providing new concepts for VC prevention and treatment.
Collapse
Affiliation(s)
- Han Jiang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Lihua Li
- Department of Pathology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Lili Zhang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Guangyao Zang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Zhen Sun
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Zhongqun Wang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
- *Correspondence: Zhongqun Wang,
| |
Collapse
|
37
|
Chen J, Zhang X, Millican R, Lynd T, Gangasani M, Malhotra S, Sherwood J, Hwang PT, Cho Y, Brott BC, Qin G, Jo H, Yoon YS, Jun HW. Recent Progress in in vitro Models for Atherosclerosis Studies. Front Cardiovasc Med 2022; 8:790529. [PMID: 35155603 PMCID: PMC8829969 DOI: 10.3389/fcvm.2021.790529] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 12/21/2021] [Indexed: 12/13/2022] Open
Abstract
Atherosclerosis is the primary cause of hardening and narrowing arteries, leading to cardiovascular disease accounting for the high mortality in the United States. For developing effective treatments for atherosclerosis, considerable efforts have been devoted to developing in vitro models. Compared to animal models, in vitro models can provide great opportunities to obtain data more efficiently, economically. Therefore, this review discusses the recent progress in in vitro models for atherosclerosis studies, including traditional two-dimensional (2D) systems cultured on the tissue culture plate, 2D cell sheets, and recently emerged microfluidic chip models with 2D culture. In addition, advanced in vitro three-dimensional models such as spheroids, cell-laden hydrogel constructs, tissue-engineered blood vessels, and vessel-on-a-chip will also be covered. Moreover, the functions of these models are also summarized along with model discussion. Lastly, the future perspectives of this field are discussed.
Collapse
Affiliation(s)
- Jun Chen
- Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, AL, United States
| | - Xixi Zhang
- Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, AL, United States
| | | | - Tyler Lynd
- Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, AL, United States
| | - Manas Gangasani
- Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, AL, United States
| | - Shubh Malhotra
- Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, AL, United States
| | | | | | - Younghye Cho
- Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, AL, United States
- Family Medicine Clinic, Obesity, Metabolism, and Nutrition Center and Research Institute of Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
| | - Brigitta C. Brott
- Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, AL, United States
- Endomimetics, LLC., Birmingham, AL, United States
- Division of Cardiovascular Disease, School of Medicine, The University of Alabama at Birmingham, Birmingham, AL, United States
| | - Gangjian Qin
- Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, AL, United States
| | - Hanjoong Jo
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States
| | - Young-sup Yoon
- Division of Cardiology, Department of Medicine, Emory University, Atlanta, GA, United States
- Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul, South Korea
| | - Ho-Wook Jun
- Department of Biomedical Engineering, The University of Alabama at Birmingham, Birmingham, AL, United States
- Endomimetics, LLC., Birmingham, AL, United States
| |
Collapse
|
38
|
Concilia G, Lai A, Thurgood P, Pirogova E, Baratchi S, Khoshmanesh K. Investigating the mechanotransduction of transient shear stress mediated by Piezo1 ion channel using a 3D printed dynamic gravity pump. LAB ON A CHIP 2022; 22:262-271. [PMID: 34931212 DOI: 10.1039/d1lc00927c] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Microfluidic systems are widely used for studying the mechanotransduction of flow-induced shear stress in mechanosensitive cells. However, these studies are generally performed under constant flow rates, mainly, due to the deficiency of existing pumps for generating transient flows. To address this limitation, we have developed a unique dynamic gravity pump to generate transient flows in microfluidics. The pump utilises a motorised 3D-printed cam-lever mechanism to change the inlet pressure of the system in repeated cycles. 3D printing technology facilitates the rapid and low-cost prototyping of the pump. Customised transient flow patterns can be generated by modulating the profile, size, and rotational speed of the cam, location of the hinge along the lever, and the height of the syringe. Using this unique dynamic gravity pump, we investigated the mechanotransduction of shear stress in HEK293 cells stably expressing Piezo1 mechanosensitive ion channel under transient flows. The controllable, simple, low-cost, compact, and modular design of the pump makes it suitable for studying the mechanobiology of shear sensitive cells under transient flows.
Collapse
Affiliation(s)
| | - Austin Lai
- School of Health & Biomedical Sciences, RMIT University, Bundoora, Victoria, Australia.
| | - Peter Thurgood
- School of Engineering, RMIT University, Melbourne, Victoria, Australia.
| | - Elena Pirogova
- School of Engineering, RMIT University, Melbourne, Victoria, Australia.
| | - Sara Baratchi
- School of Health & Biomedical Sciences, RMIT University, Bundoora, Victoria, Australia.
| | | |
Collapse
|
39
|
Sunderland K, Jiang J, Zhao F. Disturbed flow's impact on cellular changes indicative of vascular aneurysm initiation, expansion, and rupture: A pathological and methodological review. J Cell Physiol 2022; 237:278-300. [PMID: 34486114 PMCID: PMC8810685 DOI: 10.1002/jcp.30569] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 08/06/2021] [Accepted: 08/16/2021] [Indexed: 01/03/2023]
Abstract
Aneurysms are malformations within the arterial vasculature brought on by the structural breakdown of the microarchitecture of the vessel wall, with aneurysms posing serious health risks in the event of their rupture. Blood flow within vessels is generally laminar with high, unidirectional wall shear stressors that modulate vascular endothelial cell functionality and regulate vascular smooth muscle cells. However, altered vascular geometry induced by bifurcations, significant curvature, stenosis, or clinical interventions can alter the flow, generating low stressor disturbed flow patterns. Disturbed flow is associated with altered cellular morphology, upregulated expression of proteins modulating inflammation, decreased regulation of vascular permeability, degraded extracellular matrix, and heightened cellular apoptosis. The understanding of the effects disturbed flow has on the cellular cascades which initiate aneurysms and promote their subsequent growth can further elucidate the nature of this complex pathology. This review summarizes the current knowledge about the disturbed flow and its relation to aneurysm pathology, the methods used to investigate these relations, as well as how such knowledge has impacted clinical treatment methodologies. This information can contribute to the understanding of the development, growth, and rupture of aneurysms and help develop novel research and aneurysmal treatment techniques.
Collapse
Affiliation(s)
- Kevin Sunderland
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931
| | - Jingfeng Jiang
- Department of Biomedical Engineering, Michigan Technological University, Houghton, MI 49931,Corresponding Authors: Feng Zhao, 101 Bizzell Street, College Station, TX 77843-312, Tel : 979-458-1239, , Jingfeng Jiang, 1400 Townsend Dr., Houghton, MI 49931, Tel: 906-487-1943
| | - Feng Zhao
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843,Corresponding Authors: Feng Zhao, 101 Bizzell Street, College Station, TX 77843-312, Tel : 979-458-1239, , Jingfeng Jiang, 1400 Townsend Dr., Houghton, MI 49931, Tel: 906-487-1943
| |
Collapse
|
40
|
Aguilera Suarez S, Sekar NC, Nguyen N, Lai A, Thurgood P, Zhou Y, Needham S, Pirogova E, Khoshmanesh K, Baratchi S. Studying the Mechanobiology of Aortic Endothelial Cells Under Cyclic Stretch Using a Modular 3D Printed System. Front Bioeng Biotechnol 2021; 9:791116. [PMID: 34957080 PMCID: PMC8698250 DOI: 10.3389/fbioe.2021.791116] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Accepted: 11/15/2021] [Indexed: 02/05/2023] Open
Abstract
Here, we describe a motorized cam-driven system for the cyclic stretch of aortic endothelial cells. Our modular design allows for generating customized spatiotemporal stretch profiles by varying the profile and size of 3D printed cam and follower elements. The system is controllable, compact, inexpensive, and amenable for parallelization and long-term experiments. Experiments using human aortic endothelial cells show significant changes in the cytoskeletal structure and morphology of cells following exposure to 5 and 10% cyclic stretch over 9 and 16 h. The system provides upportunities for exploring the complex molecular and cellular processes governing the response of mechanosensitive cells under cyclic stretch.
Collapse
Affiliation(s)
| | - Nadia Chandra Sekar
- School of Health and Biomedical Sciences, RMIT University, Melbourne, VIC, Australia
| | - Ngan Nguyen
- School of Engineering, RMIT University, Melbourne, VIC, Australia
| | - Austin Lai
- School of Health and Biomedical Sciences, RMIT University, Melbourne, VIC, Australia
| | - Peter Thurgood
- School of Engineering, RMIT University, Melbourne, VIC, Australia
| | - Ying Zhou
- School of Health and Biomedical Sciences, RMIT University, Melbourne, VIC, Australia
| | | | - Elena Pirogova
- School of Engineering, RMIT University, Melbourne, VIC, Australia
| | | | - Sara Baratchi
- School of Health and Biomedical Sciences, RMIT University, Melbourne, VIC, Australia
| |
Collapse
|
41
|
Thurgood P, Concilia G, Tran N, Nguyen N, Hawke AJ, Pirogova E, Jex AR, Peter K, Baratchi S, Khoshmanesh K. Generation of programmable dynamic flow patterns in microfluidics using audio signals. LAB ON A CHIP 2021; 21:4672-4684. [PMID: 34739024 DOI: 10.1039/d1lc00568e] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Customised audio signals, such as musical notes, can be readily generated by audio software on smartphones and played over audio speakers. Audio speakers translate electrical signals into the mechanical motion of the speaker cone. Coupling the inlet tube to the speaker cone causes the harmonic oscillation of the tube, which in turn changes the velocity profile and flow rate. We employ this strategy for generating programmable dynamic flow patterns in microfluidics. We show the generation of customised rib and vortex patterns through the application of multi-tone audio signals in water-based and whole blood samples. We demonstrate the precise capability to control the number and extent of the ribs and vortices by simply setting the frequency ratio of two- and three-tone audio signals. We exemplify potential applications of tube oscillation for studying the functional responses of circulating immune cells under pathophysiological shear rates. The system is programmable, compact, low-cost, biocompatible, and durable. These features make it suitable for a variety of applications across chemistry, biology, and physics.
Collapse
Affiliation(s)
- Peter Thurgood
- School of Engineering, RMIT University, Melbourne, Victoria, Australia.
| | | | - Nhiem Tran
- School of Science, RMIT University, Melbourne, Victoria, Australia
| | - Ngan Nguyen
- School of Engineering, RMIT University, Melbourne, Victoria, Australia.
| | - Adam J Hawke
- School of Engineering, RMIT University, Melbourne, Victoria, Australia.
| | - Elena Pirogova
- School of Engineering, RMIT University, Melbourne, Victoria, Australia.
| | - Aaron R Jex
- Population Health and Immunity Division, The Walter and Eliza Hall Institute of Medical Research, Parkville, Victoria, Australia
- Faculty of Veterinary and Agricultural Sciences, The University of Melbourne, Parkville, Victoria, Australia
| | - Karlheinz Peter
- Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia
- Department of Cardiometabolic Health, The University of Melbourne, Parkville, Victoria, Australia
| | - Sara Baratchi
- School of Health & Biomedical Sciences, RMIT University, Bundoora, Victoria, Australia.
| | | |
Collapse
|
42
|
Nguyen N, Thurgood P, Sekar NC, Chen S, Pirogova E, Peter K, Baratchi S, Khoshmanesh K. Microfluidic models of the human circulatory system: versatile platforms for exploring mechanobiology and disease modeling. Biophys Rev 2021; 13:769-786. [PMID: 34777617 DOI: 10.1007/s12551-021-00815-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Accepted: 06/22/2021] [Indexed: 02/07/2023] Open
Abstract
The human circulatory system is a marvelous fluidic system, which is very sensitive to biophysical and biochemical cues. The current animal and cell culture models do not recapitulate the functional properties of the human circulatory system, limiting our ability to fully understand the complex biological processes underlying the dysfunction of this multifaceted system. In this review, we discuss the unique ability of microfluidic systems to recapitulate the biophysical, biochemical, and functional properties of the human circulatory system. We also describe the remarkable capacity of microfluidic technologies for exploring the complex mechanobiology of the cardiovascular system, mechanistic studying of cardiovascular diseases, and screening cardiovascular drugs with the additional benefit of reducing the need for animal models. We also discuss opportunities for further advancement in this exciting field.
Collapse
Affiliation(s)
- Ngan Nguyen
- School of Engineering, RMIT University, Melbourne, Australia
| | - Peter Thurgood
- School of Engineering, RMIT University, Melbourne, Australia
| | - Nadia Chandra Sekar
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Australia
| | - Sheng Chen
- School of Engineering, RMIT University, Melbourne, Australia
| | - Elena Pirogova
- School of Engineering, RMIT University, Melbourne, Australia
| | - Karlheinz Peter
- Baker Heart and Diabetes Institute, Melbourne, Australia.,Department of Cardiometabolic Health, The University of Melbourne, Parkville, Australia
| | - Sara Baratchi
- School of Health and Biomedical Sciences, RMIT University, Bundoora, Australia
| | | |
Collapse
|
43
|
Haase K, Piatti F, Marcano M, Shin Y, Visone R, Redaelli A, Rasponi M, Kamm RD. Physiologic flow-conditioning limits vascular dysfunction in engineered human capillaries. Biomaterials 2021; 280:121248. [PMID: 34794827 DOI: 10.1016/j.biomaterials.2021.121248] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 11/05/2021] [Accepted: 11/08/2021] [Indexed: 02/02/2023]
Abstract
Hemodynamics play a central role in the health and disease of the coronary and peripheral vascular systems. Vessel-lining endothelial cells are known mechanosensors, responding to disturbances in flow - with mechanosensitivity hypothesized to change in response to metabolic demands. The health of our smallest microvessels have been lauded as a prognostic marker for cardiovascular health. Yet, despite numerous animal models, studying these small vessels has proved difficult. Microfluidic technologies have allowed a number of 3D vascular models to be developed and used to investigate human vessels. Here, two such systems are employed for examining 1) interstitial flow effects on neo-vessel formation, and 2) the effects of flow-conditioning on vascular remodeling following sustained static culture. Interstitial flow is shown to enhance early vessel formation via significant remodeling of vessels and interconnected tight junctions of the endothelium. In formed vessels, continuous flow maintains a stable vascular diameter and causes significant remodeling, contrasting the continued anti-angiogenic decline of statically cultured vessels. This study is the first to couple complex 3D computational flow distributions and microvessel remodeling from microvessels grown on-chip (exposed to flow or no-flow conditions). Flow-conditioned vessels (WSS < 1Pa for 30 μm vessels) increase endothelial barrier function, result in significant changes in gene expression and reduce reactive oxygen species and anti-angiogenic cytokines. Taken together, these results demonstrate microvessel mechanosensitivity to flow-conditioning, which limits deleterious vessel regression in vitro, and could have implications for future modeling of reperfusion/no-flow conditions.
Collapse
Affiliation(s)
- Kristina Haase
- Dept. of Mechanical Engineering, MIT, Cambridge, MA, USA
| | - Filippo Piatti
- Dept. of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | | | - Yoojin Shin
- Dept. of Mechanical Engineering, MIT, Cambridge, MA, USA
| | - Roberta Visone
- Dept. of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Alberto Redaelli
- Dept. of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Marco Rasponi
- Dept. of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Roger D Kamm
- Dept. of Mechanical Engineering, MIT, Cambridge, MA, USA; Dept. of Biological Engineering, MIT, Cambridge, MA, USA.
| |
Collapse
|
44
|
Vasculature-on-chip for Assessment of Bioresorbable Scaffolds and Endothelial Barrier Integrity. J Cardiovasc Pharmacol 2021; 78:515-522. [PMID: 34651600 DOI: 10.1097/fjc.0000000000001086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 05/29/2021] [Indexed: 11/26/2022]
Abstract
ABSTRACT Endothelial cells adhere to one another through junctional structures formed by intercellular adhesion molecules. These intercellular proteins regulate barrier function in response to the hemodynamic shear rate and enable the selective passage of solutes and fluids across the endothelium. After endovascular device implantation, the endothelial barrier is compromised and becomes discontinuous, which increases permeability, allowing transmigration of leukocytes and lipoproteins and leading to the accumulation of lipid-laden foamy macrophages in the subendothelial space. Drug-coated bioresorbable vascular scaffold implants have been associated with unexpected thrombotic complications, which were not predicted in animals because of dissimilarities in endothelial regeneration and realignment between animals and humans. The development of a microengineered, microfluidics-based system of patterned channels lined with human endothelial and smooth muscle cells perfused with blood allows for the evaluation of endothelial function and barrier integrity. This review highlights the translational potential of vasculature-on-chip, which recreates the microphysiological milieu to evaluate the impact of drug-eluting bioresorbable vascular scaffolds on endothelial barrier integrity and to characterize polymer biodegradation behavior and drug release kinetic profiles over time.
Collapse
|
45
|
Lu RXZ, Radisic M. Organ-on-a-chip platforms for evaluation of environmental nanoparticle toxicity. Bioact Mater 2021; 6:2801-2819. [PMID: 33665510 PMCID: PMC7900603 DOI: 10.1016/j.bioactmat.2021.01.021] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 01/20/2021] [Accepted: 01/20/2021] [Indexed: 02/07/2023] Open
Abstract
Despite showing a great promise in the field of nanomedicine, nanoparticles have gained a significant attention from regulatory agencies regarding their possible adverse health effects upon environmental exposure. Whether those nanoparticles are generated through intentional or unintentional means, the constant exposure to nanomaterials can inevitably lead to unintended consequences based on epidemiological data, yet the current understanding of nanotoxicity is insufficient relative to the rate of their emission in the environment and the lack of predictive platforms that mimic the human physiology. This calls for a development of more physiologically relevant models, which permit the comprehensive and systematic examination of toxic properties of nanoparticles. With the advancement in microfabrication techniques, scientists have shifted their focus on the development of an engineered system that acts as an intermediate between a well-plate system and animal models, known as organ-on-a-chips. The ability of organ-on-a-chip models to recapitulate in vivo like microenvironment and responses offers a new avenue for nanotoxicological research. In this review, we aim to provide overview of assessing potential risks of nanoparticle exposure using organ-on-a-chip systems and their potential to delineate biological mechanisms of epidemiological findings.
Collapse
Affiliation(s)
- Rick Xing Ze Lu
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | - Milica Radisic
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada
- Department of Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, ON, Canada
- Toronto General Research Institute, University Health Network, Toronto, ON, Canada
- The Heart and Stroke/Richard Lewar Centre of Excellence, Toronto, ON, Canada
| |
Collapse
|
46
|
Shinge SAU, Zhang D, Achu Muluh T, Nie Y, Yu F. Mechanosensitive Piezo1 Channel Evoked-Mechanical Signals in Atherosclerosis. J Inflamm Res 2021; 14:3621-3636. [PMID: 34349540 PMCID: PMC8328000 DOI: 10.2147/jir.s319789] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 07/03/2021] [Indexed: 12/18/2022] Open
Abstract
Recently, more and more works have focused and used extensive resources on atherosclerosis research, which is one of the major causes of death globally. Alongside traditional risk factors, such as hyperlipidemia, smoking, hypertension, obesity, and diabetes, mechanical forces, including shear stress, pressure and stretches exerted on endothelial cells by flow, is proved to be crucial in atherosclerosis development. Studies have recognized the mechanosensitive Piezo1 channel as a special sensor and transducer of various mechanical forces into biochemical signals, and recent studies report its role in atherosclerosis through different mechanical forces in pressure, stretching and turbulent shear stress. Based on our expertise in this field and considering the recent advancement of atherosclerosis research, we will be focusing on the function of Piezo1 and its involvement in various cellular mechanisms and consequent involvement in the development of atherosclerosis in this review. Also, we will discuss various functions of Piezo1 involvement in atherosclerosis and come up with new mechanistic insight for future research. Based on the recent findings, we suggest Piezo1 as a valid candidate for novel therapeutic innovations, in which deep exploration and translating its findings into the clinic will be a new therapeutic strategy for cardiovascular diseases, particularly atherosclerosis.
Collapse
Affiliation(s)
- Shafiu A Umar Shinge
- Cardiovascular Surgery Department, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, People’s Republic of China
| | - Daifang Zhang
- Cardiovascular Surgery Department, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, People’s Republic of China
- Clinical Research Center, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, People’s Republic of China
| | - Tobias Achu Muluh
- Oncology Department, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, People’s Republic of China
| | - Yongmei Nie
- Cardiovascular Surgery Department, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, People’s Republic of China
- Collaborative Innovation Center for Prevention and Treatment of Cardiovascular Disease of Sichuan Province, Southwest Medical University, Luzhou, Sichuan, People’s Republic of China
| | - Fengxu Yu
- Cardiovascular Surgery Department, Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, People’s Republic of China
- Collaborative Innovation Center for Prevention and Treatment of Cardiovascular Disease of Sichuan Province, Southwest Medical University, Luzhou, Sichuan, People’s Republic of China
| |
Collapse
|
47
|
Dessalles CA, Leclech C, Castagnino A, Barakat AI. Integration of substrate- and flow-derived stresses in endothelial cell mechanobiology. Commun Biol 2021; 4:764. [PMID: 34155305 PMCID: PMC8217569 DOI: 10.1038/s42003-021-02285-w] [Citation(s) in RCA: 104] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Accepted: 06/02/2021] [Indexed: 02/05/2023] Open
Abstract
Endothelial cells (ECs) lining all blood vessels are subjected to large mechanical stresses that regulate their structure and function in health and disease. Here, we review EC responses to substrate-derived biophysical cues, namely topography, curvature, and stiffness, as well as to flow-derived stresses, notably shear stress, pressure, and tensile stresses. Because these mechanical cues in vivo are coupled and are exerted simultaneously on ECs, we also review the effects of multiple cues and describe burgeoning in vitro approaches for elucidating how ECs integrate and interpret various mechanical stimuli. We conclude by highlighting key open questions and upcoming challenges in the field of EC mechanobiology.
Collapse
Affiliation(s)
- Claire A Dessalles
- LadHyX, CNRS, Ecole polytechnique, Institut polytechnique de Paris, Palaiseau, France
| | - Claire Leclech
- LadHyX, CNRS, Ecole polytechnique, Institut polytechnique de Paris, Palaiseau, France
| | - Alessia Castagnino
- LadHyX, CNRS, Ecole polytechnique, Institut polytechnique de Paris, Palaiseau, France
| | - Abdul I Barakat
- LadHyX, CNRS, Ecole polytechnique, Institut polytechnique de Paris, Palaiseau, France.
| |
Collapse
|
48
|
Wasson EM, Dubbin K, Moya ML. Go with the flow: modeling unique biological flows in engineered in vitro platforms. LAB ON A CHIP 2021; 21:2095-2120. [PMID: 34008661 DOI: 10.1039/d1lc00014d] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Interest in recapitulating in vivo phenomena in vitro using organ-on-a-chip technology has grown rapidly and with it, attention to the types of fluid flow experienced in the body has followed suit. These platforms offer distinct advantages over in vivo models with regards to human relevance, cost, and control of inputs (e.g., controlled manipulation of biomechanical cues from fluid perfusion). Given the critical role biophysical forces play in several tissues and organs, it is therefore imperative that engineered in vitro platforms capture the complex, unique flow profiles experienced in the body that are intimately tied with organ function. In this review, we outline the complex and unique flow regimes experienced by three different organ systems: blood vasculature, lymphatic vasculature, and the intestinal system. We highlight current state-of-the-art platforms that strive to replicate physiological flows within engineered tissues while introducing potential limitations in current approaches.
Collapse
Affiliation(s)
- Elisa M Wasson
- Material Engineering Division, Lawrence Livermore National Laboratory, 7000 East Ave L-222, Livermore, CA 94551, USA.
| | - Karen Dubbin
- Material Engineering Division, Lawrence Livermore National Laboratory, 7000 East Ave L-222, Livermore, CA 94551, USA.
| | - Monica L Moya
- Material Engineering Division, Lawrence Livermore National Laboratory, 7000 East Ave L-222, Livermore, CA 94551, USA.
| |
Collapse
|
49
|
Walther BK, Rajeeva Pandian NK, Gold KA, Kiliç ES, Sama V, Gu J, Gaharwar AK, Guiseppi-Elie A, Cooke JP, Jain A. Mechanotransduction-on-chip: vessel-chip model of endothelial YAP mechanobiology reveals matrix stiffness impedes shear response. LAB ON A CHIP 2021; 21:1738-1751. [PMID: 33949409 PMCID: PMC9761985 DOI: 10.1039/d0lc01283a] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Endothelial mechanobiology is a key consideration in the progression of vascular dysfunction, including atherosclerosis. However mechanistic connections between the clinically associated physical stimuli, vessel stiffness and shear stress, and how they interact to modulate plaque progression remain incompletely characterized. Vessel-chip systems are excellent candidates for modeling vascular mechanobiology as they may be engineered from the ground up, guided by the mechanical parameters present in human arteries and veins, to recapitulate key features of the vasculature. Here, we report extensive validation of a vessel-chip model of endothelial yes-associated protein (YAP) mechanobiology, a protein sensitive to both matrix stiffness and shearing forces and, importantly, implicated in atherosclerotic progression. Our model captures the established endothelial mechanoresponse, with endothelial alignment, elongation, reduction of adhesion molecules, and YAP cytoplasmic retention under high laminar shear. Conversely, we observed disturbed morphology, inflammation, and nuclear partitioning under low, high, and high oscillatory shear. Examining targets of YAP transcriptional co-activation, connective tissue growth factor (CTGF) is strongly downregulated by high laminar shear, whereas it is strongly upregulated by low shear or oscillatory flow. Ankyrin repeat domain 1 (ANKRD1) is only upregulated by high oscillatory shear. Verteporfin inhibition of YAP reduced the expression of CTGF but did not affect ANKRD1. Lastly, substrate stiffness modulated the endothelial shear mechanoresponse. Under high shear, softer substrates showed the lowest nuclear localization of YAP whereas stiffer substrates increased nuclear localization. Low shear strongly increased nuclear localization of YAP across stiffnesses. Together, we have validated a model of endothelial mechanobiology and describe a clinically relevant biological connection between matrix stiffness, shear stress, and endothelial activation via YAP mechanobiology.
Collapse
Affiliation(s)
- Brandon K Walther
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA. and Department of Cardiovascular Sciences, Houston Methodist Institute for Academic Medicine, Houston Methodist Research Institute, 6670 Bertner Ave., Houston, Texas 77030, USA.
| | | | - Karli A Gold
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA.
| | - Ecem S Kiliç
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA.
| | - Vineeth Sama
- Department of Biomedical Engineering, Clemson University, Clemson, South Carolina 29634, USA.
| | - Jianhua Gu
- Department of Cardiovascular Sciences, Houston Methodist Institute for Academic Medicine, Houston Methodist Research Institute, 6670 Bertner Ave., Houston, Texas 77030, USA.
| | - Akhilesh K Gaharwar
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA. and Department of Materials Science, Texas A&M University, College Station, Texas 77843, USA
| | - Anthony Guiseppi-Elie
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA. and Department of Cardiovascular Sciences, Houston Methodist Institute for Academic Medicine, Houston Methodist Research Institute, 6670 Bertner Ave., Houston, Texas 77030, USA. and ABTECH Scientific, Inc., Biotechnology Research Park, 800 East Leigh Street, Richmond, Virginia 23219, USA and Department of Biomedical Engineering, Anderson University, Anderson, South Carolina 29621, USA.
| | - John P Cooke
- Department of Cardiovascular Sciences, Houston Methodist Institute for Academic Medicine, Houston Methodist Research Institute, 6670 Bertner Ave., Houston, Texas 77030, USA.
| | - Abhishek Jain
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA. and Department of Cardiovascular Sciences, Houston Methodist Institute for Academic Medicine, Houston Methodist Research Institute, 6670 Bertner Ave., Houston, Texas 77030, USA. and Department of Medical Physiology, College of Medicine, Texas A&M Health Science Center, Bryan, TX 77807, USA
| |
Collapse
|
50
|
Shen N, Zhang Y, Raza A, Chang L, Wang JY. Effects of the micro/nanostructure of electrospun zein fibres on cells in simulated blood flow environment. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 122:111900. [PMID: 33641903 DOI: 10.1016/j.msec.2021.111900] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 11/21/2020] [Accepted: 01/17/2021] [Indexed: 12/14/2022]
Abstract
In order to prevent thrombosis, reduce intima hyperplasia, and to maintain long-term patency after implantation of an artificial blood vessel, the formation of intact endothelial cells layer on an inner surface of graft is desirable. The present study aimed to improve endothelial cell adhesion by regulating the morphology of the inner surface of artificial blood vessels. Zein fibre membranes with three fibre diameters (small, ~100 nm; medium, ~500 nm; and large, ~1000 nm) were constructed by electrospinning. A flow chamber device was designed to simulate the blood flow environment. The morphology and adhesion of human umbilical vein fusion cells (EA.hy926) on the surface of the fibre membranes were studied under a shear stress of approximately 15 dynes/cm2. The results showed that oriented electrospun zein fibre surfaces with both medium- and large-diameter fibres can regulate the morphology of endothelial cells (EA.hy926), which are aligned by the fibre direction. The three fibre membranes improved the adhesion of endothelial cells significantly compared to that on the flat membrane. When the fibre direction was fixed parallel to the fluid direction, the medium-diameter oriented-fibre membrane could significantly improve the ability endothelial cells to resist shear stress, and there was a significant difference at 1, 2 and 4 h time points compared with the shear stress resistance on the small-diameter and large-diameter oriented-fibre membranes. When the fibre direction was perpendicular to the fluid direction, again the medium-diameter oriented-fibre membrane improved the ability of endothelial cells to resist shear stress significantly at 1 and 2 h time points. It was concluded that by changing the diameter and arrangement of electrospun fibres, cell morphology control and shear stress resistance can be achieved.
Collapse
Affiliation(s)
- Naian Shen
- School of Biomedical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China
| | - Yue Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China
| | - Ali Raza
- School of Biomedical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China
| | - Liu Chang
- School of Biomedical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China
| | - Jin-Ye Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China.
| |
Collapse
|