1
|
Agarwal S, Hamidizadeh M, Bier FF. Detection of Reverse Transcriptase LAMP-Amplified Nucleic Acid from Oropharyngeal Viral Swab Samples Using Biotinylated DNA Probes through a Lateral Flow Assay. Biosensors (Basel) 2023; 13:988. [PMID: 37998163 PMCID: PMC10669123 DOI: 10.3390/bios13110988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 11/06/2023] [Accepted: 11/10/2023] [Indexed: 11/25/2023]
Abstract
This study focuses on three key aspects: (a) crude throat swab samples in a viral transport medium (VTM) as templates for RT-LAMP reactions; (b) a biotinylated DNA probe with enhanced specificity for LFA readouts; and (c) a digital semi-quantification of LFA readouts. Throat swab samples from SARS-CoV-2 positive and negative patients were used in their crude (no cleaning or pre-treatment) forms for the RT-LAMP reaction. The samples were heat-inactivated but not treated for any kind of nucleic acid extraction or purification. The RT-LAMP (20 min processing time) product was read out by an LFA approach using two labels: FITC and biotin. FITC was enzymatically incorporated into the RT-LAMP amplicon with the LF-LAMP primer, and biotin was introduced using biotinylated DNA probes, specifically for the amplicon region after RT-LAMP amplification. This assay setup with biotinylated DNA probe-based LFA readouts of the RT-LAMP amplicon was 98.11% sensitive and 96.15% specific. The LFA result was further analysed by a smartphone-based IVD device, wherein the T-line intensity was recorded. The LFA T-line intensity was then correlated with the qRT-PCR Ct value of the positive swab samples. A digital semi-quantification of RT-LAMP-LFA was reported with a correlation coefficient of R2 = 0.702. The overall RT-LAMP-LFA assay time was recorded to be 35 min with a LoD of three RNA copies/µL (Ct-33). With these three advancements, the nucleic acid testing-point of care technique (NAT-POCT) is exemplified as a versatile biosensor platform with great potential and applicability for the detection of pathogens without the need for sample storage, transportation, or pre-processing.
Collapse
Affiliation(s)
- Saloni Agarwal
- Institute for Biochemistry and Biology, Chair of Molecular Bioanalysis and Bioelectronics, University of Potsdam, Karl-Liebknecht-Strasse 24/25, 14476 Potsdam, Germany; (S.A.); (M.H.)
| | - Mojdeh Hamidizadeh
- Institute for Biochemistry and Biology, Chair of Molecular Bioanalysis and Bioelectronics, University of Potsdam, Karl-Liebknecht-Strasse 24/25, 14476 Potsdam, Germany; (S.A.); (M.H.)
| | - Frank F. Bier
- Institute for Biochemistry and Biology, Chair of Molecular Bioanalysis and Bioelectronics, University of Potsdam, Karl-Liebknecht-Strasse 24/25, 14476 Potsdam, Germany; (S.A.); (M.H.)
- Institute for Molecular Diagnostics and Bioanalysis-IMDB gGmbH, Am Mühlenberg 10, 14476 Potsdam, Germany
| |
Collapse
|
2
|
Egerer R, Edel B, Hornung F, Deinhardt-Emmer S, Baier M, Lewejohann JC, Pfister W, Löffler B, Rödel J. SARS-CoV-2 Testing of Emergency Department Patients Using cobas ® Liat ® and eazyplex ® Rapid Molecular Assays. Diagnostics (Basel) 2023; 13:2245. [PMID: 37443639 DOI: 10.3390/diagnostics13132245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 06/29/2023] [Accepted: 06/30/2023] [Indexed: 07/15/2023] Open
Abstract
Rapid testing for Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) of patients presenting to emergency departments (EDs) facilitates the decision for isolation on admission to hospital wards. Differences in the sensitivity of molecular assays have implications for diagnostic workflows. This study evaluated the performance of the cobas® Liat® RT-PCR, which is routinely used as the initial test for ED patients in our hospitals, compared with the eazyplex® RT-LAMP. A total of 378 oropharyngeal and nasal swabs with positive Liat® results were analysed. Residual sample aliquots were tested using NeuMoDx™, cobas® RT-PCR, and the eazyplex® assay. Patients were divided into asymptomatic (n = 157) and symptomatic (n = 221) groups according to the WHO case definition. Overall, 14% of positive Liat® results were not confirmed by RT-PCR. These samples were mainly attributed to 26.8% of asymptomatic patients, compared to 3.8% of the symptomatic group. Therefore, positive Liat® results were used to provisionally isolate patients in the ED until RT-PCR results were available. The eazyplex® assay identified 62% and 90.6% of RT-PCR-confirmed cases in asymptomatic and symptomatic patients, respectively. False-negative eazyplex® results were associated with RT-PCR Ct values > 30, and were more frequent in the asymptomatic group than in the symptomatic group (38.1% vs. 5.1%, respectively). Both the Liat® and eazyplex® assays are suitable for testing symptomatic patients. Their use in screening asymptomatic patients depends on the need to exclude any infection or identify those at high risk of transmission.
Collapse
Affiliation(s)
- Renate Egerer
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, 07747 Jena, Germany
| | - Birgit Edel
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, 07747 Jena, Germany
| | - Franziska Hornung
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, 07747 Jena, Germany
| | - Stefanie Deinhardt-Emmer
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, 07747 Jena, Germany
| | - Michael Baier
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, 07747 Jena, Germany
| | - Jan-Christoph Lewejohann
- Department of Emergency Medicine, Jena University Hospital, Friedrich Schiller University, 07747 Jena, Germany
| | - Wolfgang Pfister
- Department of Hospital Hygiene, Sophien- und Hufeland-Klinikum, 99425 Weimar, Germany
| | - Bettina Löffler
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, 07747 Jena, Germany
| | - Jürgen Rödel
- Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, 07747 Jena, Germany
| |
Collapse
|
3
|
García-Sorribes S, Lara-Hernández F, Manzano-Blasco I, Abadía-Otero J, Albert E, Mulet A, Briongos-Figuero LS, Gabella-Martín M, Torres I, Signes-Costa J, Navarro D, Martín-Escudero JC, García-García AB, Chaves FJ. Sample Treatment with Trypsin for RT-LAMP COVID-19 Diagnosis. Biology (Basel) 2023; 12:900. [PMID: 37508333 PMCID: PMC10376771 DOI: 10.3390/biology12070900] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 06/16/2023] [Accepted: 06/21/2023] [Indexed: 07/30/2023]
Abstract
The SARS-CoV-2 coronavirus is responsible for the COVID-19 pandemic resulting in a global health emergency. Given its rapid spread and high number of infected individuals, a diagnostic tool for a rapid, simple, and cost-effective detection was essential. In this work, we developed a COVID-19 diagnostic test, that incorporates a human internal control, based on the Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP). When working with synthetic SARS-CoV-2 RNA, the optimized RT-LAMP assay has a sensitivity of 10 viral copies and can be detected by fluorescence in less than 15 min or by the naked eye in 25 min using colorimetric RT-LAMP. To avoid the RNA extraction step, a pre-treatment of the sample was optimized. Subsequently, a validation was performed on 268 trypsin treated samples (including nasopharyngeal, buccal, and nasal exudates) and amplified with colorimetric RT-LAMP to evaluate its sensitivity and specificity in comparison with RT-qPCR of extracted samples. The validation results showed a sensitivity and specificity of 100% for samples with Ct ≤ 30. The rapid, simple, and inexpensive RT-LAMP SARS-CoV-2 extraction-free procedure developed may be an alternative test that could be applied for the detection of SARS-CoV-2 or adapted to detect other viruses present in saliva or nasopharyngeal samples with higher sensitivity and specificity of the antibody test.
Collapse
Affiliation(s)
| | | | - Iris Manzano-Blasco
- Genomic and Diabetes Unit, INCLIVA Biomedical Research Institute, 46010 Valencia, Spain
| | - Jessica Abadía-Otero
- Internal Medicine Service, Rio Hortega University Hospital, 47012 Valladolid, Spain
| | - Eliseo Albert
- Microbiology Service, University Clinic Hospital, INCLIVA, 46010 Valencia, Spain
| | - Alba Mulet
- Pulmonary Department, University Clinic Hospital, INCLIVA, 46010 Valencia, Spain
| | | | | | - Ignacio Torres
- Microbiology Service, University Clinic Hospital, INCLIVA, 46010 Valencia, Spain
| | - Jaime Signes-Costa
- Pulmonary Department, University Clinic Hospital, INCLIVA, 46010 Valencia, Spain
| | - David Navarro
- Microbiology Service, University Clinic Hospital, INCLIVA, 46010 Valencia, Spain
| | - Juan-Carlos Martín-Escudero
- Internal Medicine Service, Rio Hortega University Hospital, 47012 Valladolid, Spain
- Medicine Department, Valladolid University, 47002 Valladolid, Spain
| | - Ana-Bárbara García-García
- Genomic and Diabetes Unit, INCLIVA Biomedical Research Institute, 46010 Valencia, Spain
- CIBERDEM, ISCIII, 28029 Madrid, Spain
| | - Felipe Javier Chaves
- Genomic and Diabetes Unit, INCLIVA Biomedical Research Institute, 46010 Valencia, Spain
- CIBERDEM, ISCIII, 28029 Madrid, Spain
| |
Collapse
|
4
|
Bumbrah GS, Jain S, Singh S, Fatima Z, Hameed S. Diagnostic Efficacy of LAMP Assay for Human Fungal Pathogens: a Systematic Review and Meta-analysis. Curr Fungal Infect Rep 2023; 17:1-11. [PMID: 37360855 PMCID: PMC10150145 DOI: 10.1007/s12281-023-00466-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/24/2023] [Indexed: 06/28/2023]
Abstract
Purpose Human fungal infections particularly caused by Candida and Aspergillus have emerged as major public health burden. Long turnaround time and poor sensitivity of the conventional diagnostics are the major impediments for faster diagnosis of human fungal pathogens. Recent Findings To overcome these issues, molecular-based diagnostics have been developed. They offer enhanced sensitivity but require sophisticated infrastructure, skilled manpower, and remained expensive. In that context, loop-mediated isothermal amplification (LAMP) assay represents a promising alternative that facilitates visual read outs. However, to eradicate fungal infections, all forms of fungi must be accurately detected. Thus, a need for alternative testing methodologies is imperative that should be rapid, accurate and facilitate widespread adoption. Therefore, the aim of the present study is to conduct a meta-analysis to assess the diagnostic efficiency of LAMP in the detection of a panel of human fungal pathogens following PRISMA guidelines using scientific databases viz. PubMed, Google Scholar, Science Direct, Scopus, BioRxiv, and MedRxiv. Summary From various studies reported on the diagnosis of fungi, only 9 articles were identified as eligible to meet the criteria of LAMP based diagnosis. Through this meta-analysis, it was found that most of the studies were conducted in China and Japan with sputum and blood as the most common specimens to be used for LAMP assay. The collected data underlined that ITS gene and fluorescence-based detections ranked as the most used target and method. The pooled sensitivity values of meta-analysis ranged between 0.71 and 1.0 and forest plot and SROC (summary receiver operating characteristic) curve revealed a pooled specificity values between 0.13 and 1.0 with the confidence interval of 95%, respectively. The accuracy and precision rates of eligible studies mostly varied between 70 to 100% and 68 to 100%, respectively. A quality assessment based on QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) of bias and applicability was conducted which depicted low risk of bias and applicability concerns. Together, LAMP technology could be considered as a feasible alternative to current diagnostics considering high fungal burden for rapid testing in low resource regions.
Collapse
Affiliation(s)
- Gurvinder Singh Bumbrah
- Department of Forensic Sciences, Amity School of Applied Sciences, Amity University Haryana, Gurugram, 122413 Manesar India
| | - Sarika Jain
- Department of Mathematics, Amity School of Applied Sciences, Amity University Haryana, Gurugram, 122413 Manesar India
| | - Shweta Singh
- Amity Institute of Biotechnology, Amity University Haryana, Gurugram, 122413 Manesar India
| | - Zeeshan Fatima
- Amity Institute of Biotechnology, Amity University Haryana, Gurugram, 122413 Manesar India
- Department of Medical Laboratory Sciences, College of Applied Medical Sciences, University of Bisha, Bisha, 61922 Saudi Arabia
| | - Saif Hameed
- Amity Institute of Biotechnology, Amity University Haryana, Gurugram, 122413 Manesar India
| |
Collapse
|
5
|
Polatoğlu I, Oncu‐Oner T, Dalman I, Ozdogan S. COVID-19 in early 2023: Structure, replication mechanism, variants of SARS-CoV-2, diagnostic tests, and vaccine & drug development studies. MedComm (Beijing) 2023; 4:e228. [PMID: 37041762 PMCID: PMC10082934 DOI: 10.1002/mco2.228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 01/21/2023] [Accepted: 01/30/2023] [Indexed: 04/13/2023] Open
Abstract
Coronavirus Disease-19 (COVID-19) is an infectious disease caused by severe acute respiratory syndrome-coronaviruses-2 (SARS-CoV-2), a highly pathogenic and transmissible coronavirus. Most cases of COVID-19 have mild to moderate symptoms, including cough, fever, myalgias, and headache. On the other hand, this coronavirus can lead to severe complications and death in some cases. Therefore, vaccination is the most effective tool to prevent and eradicate COVID-19 disease. Also, rapid and effective diagnostic tests are critical in identifying cases of COVID-19. The COVID-19 pandemic has a dynamic structure on the agenda and contains up-to-date developments. This article has comprehensively discussed the most up-to-date pandemic situation since it first appeared. For the first time, not only the structure, replication mechanism, and variants of SARS-CoV-2 (Alpha, Beta, Gamma, Omicron, Delta, Epsilon, Kappa, Mu, Eta, Zeta, Theta, lota, Lambda) but also all the details of the pandemic, such as how it came out, how it spread, current cases, what precautions should be taken, prevention strategies, the vaccines produced, the tests developed, and the drugs used are reviewed in every aspect. Herein, the comparison of diagnostic tests for SARS-CoV-2 in terms of procedure, accuracy, cost, and time has been presented. The mechanism, safety, efficacy, and effectiveness of COVID-19 vaccines against SARS-CoV-2 variants have been evaluated. Drug studies, therapeutic targets, various immunomodulators, and antiviral molecules applied to patients with COVID-19 have been reviewed.
Collapse
Affiliation(s)
- Ilker Polatoğlu
- Department of BioengineeringManisa Celal Bayar UniversityYunusemreManisaTurkey
| | - Tulay Oncu‐Oner
- Department of BioengineeringManisa Celal Bayar UniversityYunusemreManisaTurkey
| | - Irem Dalman
- Department of BioengineeringEge UniversityBornovaIzmirTurkey
| | - Senanur Ozdogan
- Department of BioengineeringManisa Celal Bayar UniversityYunusemreManisaTurkey
| |
Collapse
|
6
|
Szobi A, Buranovská K, Vojtaššáková N, Lovíšek D, Özbaşak HÖ, Szeibeczederová S, Kapustian L, Hudáčová Z, Kováčová V, Drobná D, Putaj P, Bírová S, Čirková I, Čarnecký M, Kilián P, Jurkáček P, Čabanová V, Boršová K, Sláviková M, Vaňová V, Klempa B, Čekan P, Paul ED. Vivid COVID-19 LAMP is an ultrasensitive, quadruplexed test using LNA-modified primers and a zinc ion and 5-Br-PAPS colorimetric detection system. Commun Biol 2023; 6:233. [PMID: 36864129 PMCID: PMC9979146 DOI: 10.1038/s42003-023-04612-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 02/20/2023] [Indexed: 03/04/2023] Open
Abstract
Sensitive and rapid point-of-care assays have been crucial in the global response to SARS-CoV-2. Loop-mediated isothermal amplification (LAMP) has emerged as an important diagnostic tool given its simplicity and minimal equipment requirements, although limitations exist regarding sensitivity and the methods used to detect reaction products. We describe the development of Vivid COVID-19 LAMP, which leverages a metallochromic detection system utilizing zinc ions and a zinc sensor, 5-Br-PAPS, to circumvent the limitations of classic detection systems dependent on pH indicators or magnesium chelators. We make important strides in improving RT-LAMP sensitivity by establishing principles for using LNA-modified LAMP primers, multiplexing, and conducting extensive optimizations of reaction parameters. To enable point-of-care testing, we introduce a rapid sample inactivation procedure without RNA extraction that is compatible with self-collected, non-invasive gargle samples. Our quadruplexed assay (targeting E, N, ORF1a, and RdRP) reliably detects 1 RNA copy/µl of sample (=8 copies/reaction) from extracted RNA and 2 RNA copies/µl of sample (=16 copies/reaction) directly from gargle samples, making it one of the most sensitive RT-LAMP tests and even comparable to RT-qPCR. Additionally, we demonstrate a self-contained, mobile version of our assay in a variety of high-throughput field testing scenarios on nearly 9,000 crude gargle samples. Vivid COVID-19 LAMP can be an important asset for the endemic phase of COVID-19 as well as preparing for future pandemics.
Collapse
Affiliation(s)
- Adrián Szobi
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Katarína Buranovská
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Nina Vojtaššáková
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Daniel Lovíšek
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Halil Önder Özbaşak
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Sandra Szeibeczederová
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Liudmyla Kapustian
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Zuzana Hudáčová
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
- Stanford University, 730 Escondido Rd., Stanford, CA, 94305, USA
| | - Viera Kováčová
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
- University of Cologne, Institute for Biological Physics, Zülpicher Str. 77, 50937, Köln, Germany
| | - Diana Drobná
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Piotr Putaj
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Stanislava Bírová
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Ivana Čirková
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Martin Čarnecký
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Peter Kilián
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA
| | - Peter Jurkáček
- AstonITM s.r.o., Račianska 153, 831 54, Bratislava, Slovakia
| | - Viktória Čabanová
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská cesta 9, 845 05, Bratislava, Slovakia
| | - Kristína Boršová
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská cesta 9, 845 05, Bratislava, Slovakia
| | - Monika Sláviková
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská cesta 9, 845 05, Bratislava, Slovakia
| | - Veronika Vaňová
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská cesta 9, 845 05, Bratislava, Slovakia
- Department of Microbiology and Virology, Faculty of Natural Sciences, Comenius University, Ilkovičova 6, 842 15, Bratislava, Slovakia
| | - Boris Klempa
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská cesta 9, 845 05, Bratislava, Slovakia
- Department of Microbiology and Virology, Faculty of Natural Sciences, Comenius University, Ilkovičova 6, 842 15, Bratislava, Slovakia
| | - Pavol Čekan
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia.
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA.
| | - Evan D Paul
- MultiplexDX, s.r.o., Comenius University Science Park, Ilkovičova 8, 841 04, Bratislava, Slovakia.
- MultiplexDX, Inc., One Research Court, Suite 450, Rockville, MD, 20850, USA.
| |
Collapse
|
7
|
Moon SH, Kim SC, Kim BW, Park GJ, Chai HS, Kim YM, Kim HS, Park HS. SARS-CoV-2 molecular diagnostic point-of-care testing based on loop-mediated isothermal amplification: A prospective, single-center validation study. Heliyon 2023; 9:e14564. [PMID: 36942218 PMCID: PMC10014123 DOI: 10.1016/j.heliyon.2023.e14564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 03/04/2023] [Accepted: 03/09/2023] [Indexed: 03/17/2023] Open
Abstract
Objectives Rapid and accurate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnostic tests are crucial for controlling the spread of infections in emergency settings. This study evaluated the diagnostic accuracy of a point-of-care (POC) test based on loop-mediated isothermal amplification (LAMP) that produces rapid results within 30 min. Methods We prospectively included adult patients (age >19 years) who were diagnosed with SARS-CoV-2 infection within the last 3 days and symptomatic patients who had visited the emergency room. Posterior nasopharyngeal (PNP) swabs and throat swabs collected by physicians were used to test the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and Cohen's Kappa coefficient (k) of the POC index and reference reverse transcription quantitative polymerase chain reaction (RT-qPCR) test devices. Results Of the 352 participants, 102 (29.0%) tested positive via the RT-PCR-based reference test device; the RT-LAMP-based POC test had a sensitivity of 70.6% and specificity of 98.0%, with 93.5% PPV, 89.1% NPV, 35.5% PLR, and 3.4% NLR. Cohen's k correlation of results from the two devices was 0.74. The cycle threshold value between the positive and negative POC test results differed (17.6 vs. 24.6, p < 0.001). Conclusions The RT-LAMP POC test in the emergency medical setting has a fair predictive value in high viral load cases in terms of infectivity.
Collapse
Affiliation(s)
- Sung Hun Moon
- Department of Emergency Medicine, Chungbuk National University Hospital, 776, 1st Sunhwan-ro, Seowon-gu, Cheongju-si, Chungcheongbuk-do 28646, Republic of Korea
| | - Sang-Chul Kim
- Department of Emergency Medicine, Chungbuk National University Hospital, 776, 1st Sunhwan-ro, Seowon-gu, Cheongju-si, Chungcheongbuk-do 28646, Republic of Korea
- Department of Emergency Medicine, College of Medicine, Chungbuk National University, 1 Chungdae-ro, Seowongu, Cheongju-si, Chungcheongbuk-do 28646, Republic of Korea
| | - Byung Woo Kim
- Department of Paramedic Science, Korea National University of Transportation, 61, Daehak-ro, Jeungpyeong-gun, Chungcheongbuk-do, 27909, Republic of Korea
| | - Gwan-Jin Park
- Department of Emergency Medicine, Chungbuk National University Hospital, 776, 1st Sunhwan-ro, Seowon-gu, Cheongju-si, Chungcheongbuk-do 28646, Republic of Korea
| | - Hyun-Seok Chai
- Department of Emergency Medicine, Chungbuk National University Hospital, 776, 1st Sunhwan-ro, Seowon-gu, Cheongju-si, Chungcheongbuk-do 28646, Republic of Korea
| | - Young Min Kim
- Department of Emergency Medicine, Chungbuk National University Hospital, 776, 1st Sunhwan-ro, Seowon-gu, Cheongju-si, Chungcheongbuk-do 28646, Republic of Korea
| | - Hee Sung Kim
- Department of Internal Medicine, Chungbuk National University Hospital, 776, 1st Sunhwan-ro, Seowon-gu, Cheongju-si, Chungcheongbuk-do 28646, Republic of Korea
- College of Medicine and Medical Research Institute, Chungbuk National University, 1 Chungdae-ro, Seowongu, Cheongju-si, Chungcheongbuk-do 28646, Republic of Korea
| | - Hee Sue Park
- Department of Laboratory Medicine, Chungbuk National University Hospital, 776, 1st Sunhwan-ro, Seowon-gu, Cheongju-si, Chungcheongbuk-do 28646, Republic of Korea
- Department of Laboratory Medicine, College of Medicine, Chungbuk National University, 1 Chungdae-ro, Seowongu, Cheongju-si, Chungcheongbuk-do 28646, Republic of Korea
| |
Collapse
|
8
|
Armesto M, Charconnet M, Marimón JM, Fernández Regueiro CL, Jia J, Yan T, Sorarrain A, Grzelczak M, Sanromán M, Vicente M, Klempa B, Zubiria J, Peng Y, Zhang L, Zhang J, Lawrie CH. Validation of Rapid and Economic Colorimetric Nanoparticle Assay for SARS-CoV-2 RNA Detection in Saliva and Nasopharyngeal Swabs. Biosensors (Basel) 2023; 13:275. [PMID: 36832041 PMCID: PMC9954569 DOI: 10.3390/bios13020275] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 02/08/2023] [Accepted: 02/13/2023] [Indexed: 06/16/2023]
Abstract
Even with the widespread uptake of vaccines, the SARS-CoV-2-induced COVID-19 pandemic continues to overwhelm many healthcare systems worldwide. Consequently, massive scale molecular diagnostic testing remains a key strategy to control the ongoing pandemic, and the need for instrument-free, economic and easy-to-use molecular diagnostic alternatives to PCR remains a goal of many healthcare providers, including WHO. We developed a test (Repvit) based on gold nanoparticles that can detect SARS-CoV-2 RNA directly from nasopharyngeal swab or saliva samples with a limit of detection (LOD) of 2.1 × 105 copies mL-1 by the naked eye (or 8 × 104 copies mL-1 by spectrophotometer) in less than 20 min, without the need for any instrumentation, and with a manufacturing price of <$1. We tested this technology on 1143 clinical samples from RNA extracted from nasopharyngeal swabs (n = 188), directly from saliva samples (n = 635; assayed by spectrophotometer) and nasopharyngeal swabs (n = 320) from multiple centers and obtained sensitivity values of 92.86%, 93.75% and 94.57% and specificities of 93.22%, 97.96% and 94.76%, respectively. To our knowledge, this is the first description of a colloidal nanoparticle assay that allows for rapid nucleic acid detection at clinically relevant sensitivity without the need for external instrumentation that could be used in resource-limited settings or for self-testing.
Collapse
Affiliation(s)
- María Armesto
- Molecular Oncology Group, Biodonostia Research Institute, 20014 San Sebastián, Spain
| | - Mathias Charconnet
- Sino-Swiss Institute of Advanced Technology (SSIAT), Shanghai University, Shanghai 201907, China
| | - José M. Marimón
- Respiratory Infection and Antimicrobial Resistance Group, Biodonostia Research Institute, 20014 San Sebastián, Spain
| | | | - Jia Jia
- Sino-Swiss Institute of Advanced Technology (SSIAT), Shanghai University, Shanghai 201907, China
- School of Life Sciences, Shanghai University, Shanghai 201907, China
| | - Tingdong Yan
- School of Life Sciences, Shanghai University, Shanghai 201907, China
| | - Ane Sorarrain
- Respiratory Infection and Antimicrobial Resistance Group, Biodonostia Research Institute, 20014 San Sebastián, Spain
| | - Marek Grzelczak
- Colloidal Systems Chemistry, Centro de Física de Materiales (CSIC-UPV/EHU), 20018 San Sebastián, Spain
- Donostia Institute of Physics Centre (DIPC), 20018 San Sebastián, Spain
| | - María Sanromán
- Colloidal Systems Chemistry, Centro de Física de Materiales (CSIC-UPV/EHU), 20018 San Sebastián, Spain
- Donostia Institute of Physics Centre (DIPC), 20018 San Sebastián, Spain
| | - Mónica Vicente
- Molecular Oncology Group, Biodonostia Research Institute, 20014 San Sebastián, Spain
| | - Boris Klempa
- Biomedical Research Center, Institute of Virology, Slovak Academy of Sciences, Dúbravská Cesta 9, Bratislava 845 05, Slovakia
| | - Javier Zubiria
- Sino-Swiss Institute of Advanced Technology (SSIAT), Shanghai University, Shanghai 201907, China
| | - Yuan Peng
- Sino-Swiss Institute of Advanced Technology (SSIAT), Shanghai University, Shanghai 201907, China
| | - Lei Zhang
- Sino-Swiss Institute of Advanced Technology (SSIAT), Shanghai University, Shanghai 201907, China
| | - Jianhua Zhang
- Sino-Swiss Institute of Advanced Technology (SSIAT), Shanghai University, Shanghai 201907, China
- School of Microelectronics, Shanghai University, Shanghai 201907, China
| | - Charles H. Lawrie
- Molecular Oncology Group, Biodonostia Research Institute, 20014 San Sebastián, Spain
- Sino-Swiss Institute of Advanced Technology (SSIAT), Shanghai University, Shanghai 201907, China
- IKERBASQUE, Basque Foundation for Science, 48009 Bilbao, Spain
- Radcliffe Department of Medicine, University of Oxford, Oxford OX3 9DU, UK
| |
Collapse
|
9
|
Pollak NM, Olsson M, Marsh GA, Macdonald J, McMillan D. Evaluation of three rapid low-resource molecular tests for Nipah virus. Front Microbiol 2023; 13:1101914. [PMID: 36845977 PMCID: PMC9949527 DOI: 10.3389/fmicb.2022.1101914] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 12/13/2022] [Indexed: 02/11/2023] Open
Abstract
Accurate and timely diagnosis of Nipah virus (NiV) requires rapid, inexpensive, and robust diagnostic tests to control spread of disease. Current state of the art technologies are slow and require laboratory infrastructure that may not be available in all endemic settings. Here we report the development and comparison of three rapid NiV molecular diagnostic tests based on reverse transcription recombinase-based isothermal amplification coupled with lateral flow detection. These tests include a simple and fast one-step sample processing step that inactivates the BSL-4 pathogen, enabling safe testing without the need for multi-step RNA purification. The rapid NiV tests targeted the Nucleocapsid protein (N) gene with analytical sensitivity down to 1,000 copies/μL for synthetic NiV RNA and did not cross-react with RNA of other flaviviruses or Chikungunya virus, which can clinically present with similar febrile symptoms. Two tests detected 50,000-100,000 TCID50/mL (100-200 RNA copies/reaction) of the two distinct strains of NiV, Bangladesh (NiVB) and Malaysia (NiVM), and took 30 min from sample to result, suggesting these tests are well suited for rapid diagnosis under resource-limited conditions due to rapidity, simplicity, and low equipment requirements. These Nipah tests represent a first step toward development of near-patient NiV diagnostics that are appropriately sensitive for first-line screening, sufficiently robust for a range of peripheral settings, with potential to be safely performed outside of biohazard containment facilities.
Collapse
Affiliation(s)
- Nina M. Pollak
- Centre for Bioinnovation, University of the Sunshine Coast, Sippy Downs, QLD, Australia,DMTC Limited, Kew, VIC, Australia,School of Science, Technology and Engineering, University of the Sunshine Coast, Sippy Downs, QLD, Australia,*Correspondence: Nina M. Pollak,
| | - Malin Olsson
- Centre for Bioinnovation, University of the Sunshine Coast, Sippy Downs, QLD, Australia,DMTC Limited, Kew, VIC, Australia,School of Science, Technology and Engineering, University of the Sunshine Coast, Sippy Downs, QLD, Australia
| | - Glenn A. Marsh
- Commonwealth Scientific and Industrial Research Organisation Health and Biosecurity, Australian Centre for Disease Preparedness, Geelong, VIC, Australia
| | - Joanne Macdonald
- Centre for Bioinnovation, University of the Sunshine Coast, Sippy Downs, QLD, Australia,DMTC Limited, Kew, VIC, Australia,School of Science, Technology and Engineering, University of the Sunshine Coast, Sippy Downs, QLD, Australia,BioCifer Pty Ltd., Brisbane, QLD, Australia,Joanne Macdonald,
| | - David McMillan
- Centre for Bioinnovation, University of the Sunshine Coast, Sippy Downs, QLD, Australia,DMTC Limited, Kew, VIC, Australia,School of Science, Technology and Engineering, University of the Sunshine Coast, Sippy Downs, QLD, Australia,David McMillan,
| |
Collapse
|
10
|
Matsumura Y, Yamazaki W, Noguchi T, Yamamoto M, Nagao M. Analytical and clinical performances of seven direct detection assays for SARS-CoV-2. J Clin Virol Plus 2023; 3:100138. [PMID: 36683610 PMCID: PMC9837381 DOI: 10.1016/j.jcvp.2023.100138] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 12/28/2022] [Accepted: 01/12/2023] [Indexed: 01/14/2023] Open
Abstract
Background Direct detection tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that bypass complicated nucleic acid/antigen purification steps are promising tools for the rapid diagnosis of coronavirus disease 2019 (COVID-19). Methods To determine the analytical and clinical diagnostic performances of the direct detection assays, we compared 6 direct molecular detection assays, including two loop-mediated isothermal amplification (LAMP) assays and one lateral flow antigen assay, against the reference extraction-based RT-PCR assay using 183 respiratory samples (87 nasopharyngeal swabs, 51 saliva samples, and 45 sputum samples). Results Analytical sensitivity analysis showed that the direct RT-PCR assay of Toyobo exhibited the lowest LOD of 1,000 copies/mL. Compared with the 80 positive and 103 negative samples based on the reference assay, the Toyobo assay had the highest positive percent agreement (PPA) of 96.3%, followed by the two direct RT-PCR assays of Takara and Shimadzu and one LAMP assay of Eiken (86.3-87.5%). The Fujirebio antigen assay had the lowest PPA of 44.7% among the assays tested. The negative percent agreement of these direct detection assays was 100%, except for the Eiken assay (96.3%). Conclusions Large differences in PPA existed among the direct detection tests. Laboratories need to take these characteristics into consideration before implementing these assays.
Collapse
Affiliation(s)
- Yasufumi Matsumura
- Department of Clinical Laboratory Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto, 6068507, Japan,Corresponding author at: Department of Clinical Laboratory Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto 6068507, Japan
| | - Wataru Yamazaki
- Center for Southeast Asian Studies, Kyoto University, 46 Yoshida Shimoadachi-cho, Sakyo-ku, Kyoto, 6068501, Japan
| | - Taro Noguchi
- Department of Clinical Laboratory Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto, 6068507, Japan
| | - Masaki Yamamoto
- Department of Clinical Laboratory Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto, 6068507, Japan
| | - Miki Nagao
- Department of Clinical Laboratory Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto, 6068507, Japan
| |
Collapse
|
11
|
Bumbrah GS, Jain S, Fatima Z, Hameed S. Efficacy of LAMP assay for Mycobacterial spp. detection to prevent treatment delays and onset of drug resistance: a systematic review and meta-analysis. Drug Target Insights 2023; 17:78-89. [PMID: 37304408 PMCID: PMC10249090 DOI: 10.33393/dti.2023.2596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Accepted: 05/12/2023] [Indexed: 06/13/2023] Open
Abstract
Background Tuberculosis (TB) remains a deadly disease affecting one-third population globally. Long turnaround time and poor sensitivity of the conventional diagnostics are the major impediments for faster diagnosis of Mycobacterial spp to prevent drug resistance. To overcome these issues, molecular diagnostics have been developed. They offer enhanced sensitivity but require sophisticated infrastructure, skilled manpower and remain expensive. Methods In that context, loop-mediated isothermal amplification (LAMP) assay, recommended by the WHO in 2016 for TB diagnosis, sounds as a promising alternative that facilitates visual read outs. Therefore, the aim of the present study is to conduct a meta-analysis to assess the diagnostic efficiency of LAMP for the detection of a panel of Mycobacterium spp. following PRISMA guidelines using scientific databases. From 1600 studies reported on the diagnosis of Mycobacterium spp., a selection of 30 articles were identified as eligible to meet the criteria of LAMP based diagnosis. Results It was found that most of the studies were conducted in high disease burden nations such as India, Thailand, and Japan with sputum as the most common specimen to be used for LAMP assay. Furthermore, IS6110 gene and fluorescence-based detections ranked as the most used target and method respectively. The accuracy and precision rates mostly varied between 79.2% to 99.3% and 73.9% to 100%, respectively. Lastly, a quality assessment based on QUADAS-2 of bias and applicability was conducted. Conclusion LAMP technology could be considered as a feasible alternative to current diagnostics considering high burden for rapid testing in low resource regions.
Collapse
Affiliation(s)
- Gurvinder Singh Bumbrah
- Department of Forensic Sciences, Amity School of Applied Sciences, Amity University Haryana, Gurugram, Manesar - India
| | - Sarika Jain
- Department of Mathematics, Amity School of Applied Sciences, Amity University Haryana, Gurugram, Manesar - India
| | - Zeeshan Fatima
- Amity Institute of Biotechnology, Amity University Haryana, Gurugram, Manesar - India
- Department of Medical Laboratory Sciences, College of Applied Medical Sciences, University of Bisha, Bisha - Saudi Arabia
| | - Saif Hameed
- Amity Institute of Biotechnology, Amity University Haryana, Gurugram, Manesar - India
| |
Collapse
|
12
|
Li Y, Kim H, Ju Y, Park Y, Kang T, Yong D, Park HG. Ultrasensitive Isothermal Detection of SARS-CoV-2 Based on Self-Priming Hairpin-Utilized Amplification of the G-Rich Sequence. Anal Chem 2022; 94:17448-17455. [PMID: 36480911 PMCID: PMC9743493 DOI: 10.1021/acs.analchem.2c03442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 11/28/2022] [Indexed: 12/13/2022]
Abstract
The outbreak of the novel coronavirus disease 2019 (COVID-19) pandemic induced by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused millions of fatalities all over the world. Unquestionably, the effective and timely testing for infected individuals is the most imperative for the prevention of the ongoing pandemic. Herein, a new method was established for detecting SARS-CoV-2 based on the self-priming hairpin-utilized isothermal amplification of the G-rich sequence (SHIAG). In this strategy, the target RNA binding to the hairpin probe (HP) was uniquely devised to lead to the self-priming-mediated extension followed by the continuously repeated nicking and extension reactions, consequently generating abundant G-rich sequences from the intended reaction capable of producing fluorescence signals upon specifically interacting with thioflavin T (ThT). Based on the unique isothermal design concept, we successfully identified SARS-CoV-2 genomic RNA (gRNA) as low as 0.19 fM with excellent selectivity by applying only a single HP and further verified its practical diagnostic capability by reliably testing a total of 100 clinical specimens for COVID-19 with 100% clinical sensitivity and specificity. This study would provide notable insights into the design and evolution of new isothermal strategies for the sensitive and facile detection of SARS-CoV-2 under resource constraints.
Collapse
Affiliation(s)
- Yan Li
- Department of Chemical and Biomolecular Engineering
(BK21 Four), Korea Advanced Institute of Science and Technology
(KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon34141, Republic of
Korea
| | - Hansol Kim
- Department of Chemical and Biomolecular Engineering
(BK21 Four), Korea Advanced Institute of Science and Technology
(KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon34141, Republic of
Korea
| | - Yong Ju
- Department of Chemical and Biomolecular Engineering
(BK21 Four), Korea Advanced Institute of Science and Technology
(KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon34141, Republic of
Korea
| | - Yeonkyung Park
- Department of Chemical and Biomolecular Engineering
(BK21 Four), Korea Advanced Institute of Science and Technology
(KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon34141, Republic of
Korea
| | - Taejoon Kang
- Bionanotechnology Research Center, Korea
Research Institute of Bioscience and Biotechnology (KRIBB), Yuseong-gu,
Daejeon34141, Republic of Korea
- School of Pharmacy, Sungkyunkwan
University, 2066 Seobu-ro, Jangan-gu, Suwon, Gyeonggi-do16419,
Republic of Korea
| | - Dongeun Yong
- Department of Laboratory Medicine and
Research Institute of Bacterial Resistance, Yonsei University College of
Medicine, Seoul03722, Republic of Korea
| | - Hyun Gyu Park
- Department of Chemical and Biomolecular Engineering
(BK21 Four), Korea Advanced Institute of Science and Technology
(KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon34141, Republic of
Korea
| |
Collapse
|
13
|
Garner C, Stephen C, Pant SD, Ghorashi SA. Comparison of PCR-HRM, colorimetric LAMP and culture based diagnostic assays in the detection of endometritis caused by Streptococcus equi subsp. zooepidemicus in mares. Vet Res Commun 2022; 47:495-509. [PMID: 36538151 PMCID: PMC9765344 DOI: 10.1007/s11259-022-10047-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 11/24/2022] [Indexed: 12/24/2022]
Abstract
Streptococcus equi subsp. zooepidemicus (S. zooepidemicus) is one of the causative agents of equine endometritis. In this study, a panel of different bacterial species, and colonies derived from bacteriological cultures of 38 clinical samples, were subjected to Loop-Mediated Isothermal Amplification (LAMP) assay and PCR, followed by high-resolution melt (HRM) curve analysis. All clinical samples were genotyped into three distinct groups based on HRM curve analysis. Differences in melting curve profiles were a reflection of DNA variation in sorD gene which was confirmed by DNA sequencing. A mathematical model based on Genetic Confidence Percentage (GCP) was used in HRM curve analysis and a cut-off point value was established which differentiated S. zooepidemicus isolates without requiring visual interpretation of curve profiles. The accuracy of PCR-HRM and bacterial culture in detection of S. zooepidemicus were identical with 100% sensitivity and specificity, while LAMP assay had similar specificity but a lower sensitivity (89.5%). PCR-HRM and LAMP assay provided an effective detection method with a turn-around time of six hours for PCR-HRM and 120 min for LAMP assay, compared to a minimum three days that was required when routine bacteriological culture method was used. In summary, results indicate that LAMP had the quickest turnaround, and HRM curve analysis could potentially be used for genotyping without DNA sequencing. Any mare suspected of endometritis will benefit from developed rapid diagnostic tests for detection of S. zooepidemicus and proper treatment prior to being bred and will mitigate unnecessary treatment and antibiotic resistance.
Collapse
Affiliation(s)
- Charlotte Garner
- School of Agricultural, Environmental and Veterinary Sciences, Charles Sturt University, Wagga Wagga, NSW 2678 Australia
| | - Cyril Stephen
- School of Agricultural, Environmental and Veterinary Sciences, Charles Sturt University, Wagga Wagga, NSW 2678 Australia ,Graham Centre for Agricultural Innovation, Wagga Wagga, Australia
| | - Sameer Dinkar Pant
- School of Agricultural, Environmental and Veterinary Sciences, Charles Sturt University, Wagga Wagga, NSW 2678 Australia ,Graham Centre for Agricultural Innovation, Wagga Wagga, Australia
| | - Seyed Ali Ghorashi
- School of Agricultural, Environmental and Veterinary Sciences, Charles Sturt University, Wagga Wagga, NSW 2678 Australia ,Graham Centre for Agricultural Innovation, Wagga Wagga, Australia
| |
Collapse
|
14
|
Wang Z, Liu S. Internet of things (IoT) imbedded point-of-care SARS-CoV-2 testing in the pandemic and post-pandemic era. Biosaf Health 2022; 4:365-368. [PMID: 36168401 PMCID: PMC9502434 DOI: 10.1016/j.bsheal.2022.09.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 09/06/2022] [Accepted: 09/19/2022] [Indexed: 12/25/2022] Open
Abstract
The outbreaks of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Omicron variant in China have revealed a high rate of asymptomatic cases, making isolation and quarantine measures exceedingly difficult. Public health surveillance and intervention measures will require rapid and accurate testing preferably on-site using point-of-care tests (POCTs) technology for SARS-CoV-2 variants. However, delayed and/or inaccurate surveillance data is a major obstacle blocking the large-scale implementation of POCTs in curbing spread of infectious pathogens and reducing mortality during an outbreak. To determine levels of community transmission and timely strategies accordingly, highly sensitive and specific POCT embedded with the internet of things (IoT) technology could enable on-site screening and real-time data collection. A new Rapid Amplification with Sensitivity And Portability point-of-care test (RASAP-POCT) system based on thermal convection PCR is the first IoT-based isothermal nucleic acid amplification POCT, which can provide test results within 20-30 min using saliva and/or nasopharyngeal swab samples without nucleic acid extraction. With the IoT-imbedded feature, the RASAP-POCT system can be integrated easily and smoothly with China's existing mobile-phone-based contact tracing system, which has previously proved to be highly effective in maintaining the dynamic zero-COVID policy. Current regulatory guidelines and rules should be modified to accelerate the adoption of new technologies under an emergency use authorization (EUA).
Collapse
Affiliation(s)
- Zhaoxi Wang
- Beth Israel Deaconess Medical Center/Harvard Medical School, Boston, MA 02215, United States,Corresponding author: Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Kirstein 3, Boston, MA 02215, United States
| | - Simin Liu
- Department of Epidemiology, Brown University, Providence, RI 02912, United States
| |
Collapse
|
15
|
Patchsung M, Homchan A, Aphicho K, Suraritdechachai S, Wanitchanon T, Pattama A, Sappakhaw K, Meesawat P, Wongsatit T, Athipanyasilp A, Jantarug K, Athipanyasilp N, Buahom J, Visanpattanasin S, Niljianskul N, Chaiyen P, Tinikul R, Wichukchinda N, Mahasirimongkol S, Sirijatuphat R, Angkasekwinai N, Crone MA, Freemont PS, Joung J, Ladha A, Abudayyeh O, Gootenberg J, Zhang F, Chewapreecha C, Chanarat S, Horthongkham N, Pakotiprapha D, Uttamapinant C. A Multiplexed Cas13-Based Assay with Point-of-Care Attributes for Simultaneous COVID-19 Diagnosis and Variant Surveillance. CRISPR J 2022; 6:99-115. [PMID: 36367987 PMCID: PMC7614457 DOI: 10.1089/crispr.2022.0048] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Point-of-care (POC) nucleic acid detection technologies are poised to aid gold-standard technologies in controlling the COVID-19 pandemic, yet shortcomings in the capability to perform critically needed complex detection-such as multiplexed detection for viral variant surveillance-may limit their widespread adoption. Herein, we developed a robust multiplexed clustered regularly interspaced short palindromic repeats (CRISPR)-based detection using LwaCas13a and PsmCas13b to simultaneously diagnose severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and pinpoint the causative SARS-CoV-2 variant of concern (VOC)-including globally dominant VOCs Delta (B.1.617.2) and Omicron (B.1.1.529)-all the while maintaining high levels of accuracy upon the detection of multiple SARS-CoV-2 gene targets. The platform has several attributes suitable for POC use: premixed, freeze-dried reagents for easy use and storage; convenient direct-to-eye or smartphone-based readouts; and a one-pot variant of the multiplexed detection. To reduce reliance on proprietary reagents and enable sustainable use of such a technology in low- and middle-income countries, we locally produced and formulated our own recombinase polymerase amplification reaction and demonstrated its equivalent efficiency to commercial counterparts. Our tool-CRISPR-based detection for simultaneous COVID-19 diagnosis and variant surveillance that can be locally manufactured-may enable sustainable use of CRISPR diagnostics technologies for COVID-19 and other diseases in POC settings.
Collapse
Affiliation(s)
- Maturada Patchsung
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom
| | - Aimorn Homchan
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom.,Department of Biochemistry and Center for Excellence in Protein and Enzyme Technology, Faculty of Science, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | - Kanokpol Aphicho
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom
| | - Surased Suraritdechachai
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom
| | - Thanyapat Wanitchanon
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom.,Division of Genomic Medicine and Innovation Support, Department of Medical Sciences, Ministry of Public Health, Nonthaburi, Thailand; Hinxton, United Kingdom
| | - Archiraya Pattama
- Department of Microbiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | - Khomkrit Sappakhaw
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom
| | - Piyachat Meesawat
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom
| | - Thanakrit Wongsatit
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom
| | - Artittaya Athipanyasilp
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom.,Department of Microbiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | - Krittapas Jantarug
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom
| | - Niracha Athipanyasilp
- Department of Microbiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | - Juthamas Buahom
- Department of Microbiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | - Supapat Visanpattanasin
- Department of Biochemistry and Center for Excellence in Protein and Enzyme Technology, Faculty of Science, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | | | - Pimchai Chaiyen
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom
| | - Ruchanok Tinikul
- Department of Biochemistry and Center for Excellence in Protein and Enzyme Technology, Faculty of Science, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | - Nuanjun Wichukchinda
- Division of Genomic Medicine and Innovation Support, Department of Medical Sciences, Ministry of Public Health, Nonthaburi, Thailand; Hinxton, United Kingdom
| | - Surakameth Mahasirimongkol
- Division of Genomic Medicine and Innovation Support, Department of Medical Sciences, Ministry of Public Health, Nonthaburi, Thailand; Hinxton, United Kingdom
| | - Rujipas Sirijatuphat
- Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | - Nasikarn Angkasekwinai
- Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | - Michael A Crone
- London Biofoundry, Imperial College Translation and Innovation Hub, London, United Kingdom; Hinxton, United Kingdom.,Section of Structural and Synthetic Biology, Department of Infectious Disease, Imperial College London, London, United Kingdom; Hinxton, United Kingdom.,UK Dementia Research Institute Centre for Care Research and Technology, Imperial College London, London, United Kingdom; Hinxton, United Kingdom
| | - Paul S Freemont
- London Biofoundry, Imperial College Translation and Innovation Hub, London, United Kingdom; Hinxton, United Kingdom.,Section of Structural and Synthetic Biology, Department of Infectious Disease, Imperial College London, London, United Kingdom; Hinxton, United Kingdom.,UK Dementia Research Institute Centre for Care Research and Technology, Imperial College London, London, United Kingdom; Hinxton, United Kingdom
| | - Julia Joung
- Howard Hughes Medical Institute, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,Broad Institute of MIT and Harvard, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,McGovern Institute for Brain Research at MIT, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,Department of Biological Engineering, MIT, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,Department of Brain and Cognitive Sciences, MIT, Cambridge, Massachusetts, USA; Hinxton, United Kingdom
| | - Alim Ladha
- Howard Hughes Medical Institute, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,Broad Institute of MIT and Harvard, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,McGovern Institute for Brain Research at MIT, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,Department of Biological Engineering, MIT, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,Department of Brain and Cognitive Sciences, MIT, Cambridge, Massachusetts, USA; Hinxton, United Kingdom
| | - Omar Abudayyeh
- McGovern Institute for Brain Research at MIT, Cambridge, Massachusetts, USA; Hinxton, United Kingdom
| | - Jonathan Gootenberg
- McGovern Institute for Brain Research at MIT, Cambridge, Massachusetts, USA; Hinxton, United Kingdom
| | - Feng Zhang
- Howard Hughes Medical Institute, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,Broad Institute of MIT and Harvard, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,McGovern Institute for Brain Research at MIT, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,Department of Biological Engineering, MIT, Cambridge, Massachusetts, USA; Hinxton, United Kingdom.,Department of Brain and Cognitive Sciences, MIT, Cambridge, Massachusetts, USA; Hinxton, United Kingdom
| | - Claire Chewapreecha
- Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailand; and Hinxton, United Kingdom.,Wellcome Sanger Institute, Hinxton, United Kingdom
| | - Sittinan Chanarat
- Department of Biochemistry and Center for Excellence in Protein and Enzyme Technology, Faculty of Science, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | - Navin Horthongkham
- Department of Microbiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | - Danaya Pakotiprapha
- Department of Biochemistry and Center for Excellence in Protein and Enzyme Technology, Faculty of Science, Mahidol University, Bangkok, Thailand; Hinxton, United Kingdom
| | - Chayasith Uttamapinant
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong, Thailand; Hinxton, United Kingdom
| |
Collapse
|
16
|
Zhang X. Development of CRISPR-Mediated Nucleic Acid Detection Technologies and Their Applications in the Livestock Industry. Genes (Basel) 2022; 13. [PMID: 36360244 DOI: 10.3390/genes13112007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 10/26/2022] [Accepted: 10/31/2022] [Indexed: 11/06/2022] Open
Abstract
The rapid rate of virus transmission and pathogen mutation and evolution highlight the necessity for innovative approaches to the diagnosis and prevention of infectious diseases. Traditional technologies for pathogen detection, mostly PCR-based, involve costly/advanced equipment and skilled personnel and are therefore not feasible in resource-limited areas. Over the years, many promising methods based on clustered regularly interspaced short palindromic repeats and the associated protein systems (CRISPR/Cas), i.e., orthologues of Cas9, Cas12, Cas13 and Cas14, have been reported for nucleic acid detection. CRISPR/Cas effectors can provide one-tube reaction systems, amplification-free strategies, simultaneous multiplex pathogen detection, visual colorimetric detection, and quantitative identification as alternatives to quantitative PCR (qPCR). This review summarizes the current development of CRISPR/Cas-mediated molecular diagnostics, as well as their design software and readout methods, highlighting technical improvements for integrating CRISPR/Cas technologies into on-site applications. It further highlights recent applications of CRISPR/Cas-based nucleic acid detection in livestock industry, including emerging infectious diseases, authenticity and composition of meat/milk products, as well as sex determination of early embryos.
Collapse
|
17
|
Qu C, Luo W, Zeng Z, Lin X, Gong X, Wang X, Zhang Y, Li Y. The predictive effect of different machine learning algorithms for pressure injuries in hospitalized patients: A network meta-analyses. Heliyon 2022; 8:e11361. [DOI: 10.1016/j.heliyon.2022.e11361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 09/21/2022] [Accepted: 10/27/2022] [Indexed: 11/09/2022] Open
|
18
|
Lin Z, Lu J, Wu S, Lin X, Zheng L, Lou Y, Xiao X. A novel detection method for the pathogenic Aeromonas hydrophila expressing aerA gene and/or hlyA gene based on dualplex RAA and CRISPR/Cas12a. Front Microbiol 2022; 13:973996. [PMID: 36274718 PMCID: PMC9585296 DOI: 10.3389/fmicb.2022.973996] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 09/13/2022] [Indexed: 11/20/2022] Open
Abstract
Aeromonas hydrophila is an emerging waterborne and foodborne pathogen with pathogenicity to humans and warm water fishes, which severely threatens human health, food safety and aquaculture. A novel method for the rapid, accurate, and sensitive detection of pathogenic A. hydrophila is still needed to reduce the impact on human health and aquaculture. In this work, we developed a rapid, accurate, sensitive, and visual detection method (dRAA-CRISPR/Cas12a), without elaborate instruments, integrating the dualplex recombinase-assisted amplification (dRAA) assay and CRISPR/Cas12a system to detect pathogenic A. hydrophila expressing aerA and/or hlyA virulence genes. The dRAA-CRISPR/Cas12a method has high sensitivity, which can rapidly detect (about 45 min) A. hydrophila with the limit of detection in 2 copies of genomic DNA per reaction, and has high specificity for three pathogenic A. hydrophila strains (aerA+hlyA−, aerA−hlyA+, and aerA+hlyA+). Moreover, dRAA-CRISPR/Cas12a method shows satisfactory practicability in the analysis of the spiked human blood and stool and fish samples. These results demonstrate that our developed pathogenic A. hydrophila detection method, dRAA-CRISPR/Cas12a, is a promising potential method for the early diagnosis of human A. hydrophila infection and on-site detection of A. hydrophila in food and aquaculture.
Collapse
|
19
|
Abstract
Coronavirus disease 2019 (COVID-19) is a transmitted respiratory disease caused by the infection of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Although humankind has experienced several outbreaks of infectious diseases, the COVID-19 pandemic has the highest rate of infection and has had high levels of social and economic repercussions. The current COVID-19 pandemic has highlighted the limitations of existing virological tests, which have failed to be adopted at a rate to properly slow the rapid spread of SARS-CoV-2. Pandemic preparedness has developed as a focus of many governments around the world in the event of a future outbreak. Despite the largely widespread availability of vaccines, the importance of testing has not diminished to monitor the evolution of the virus and the resulting stages of the pandemic. Therefore, developing diagnostic technology that serves as a line of defense has become imperative. In particular, that test should satisfy three criteria to be widely adopted: simplicity, economic feasibility, and accessibility. At the heart of it all, it must enable early diagnosis in the course of infection to reduce spread. However, diagnostic manufacturers need guidance on the optimal characteristics of a virological test to ensure pandemic preparedness and to aid in the effective treatment of viral infections. Nanomaterials are a decisive element in developing COVID-19 diagnostic kits as well as a key contributor to enhance the performance of existing tests. Our objective is to develop a profile of the criteria that should be available in a platform as the target product. In this work, virus detection tests were evaluated from the perspective of the COVID-19 pandemic, and then we generalized the requirements to develop a target product profile for a platform for virus detection.
Collapse
Affiliation(s)
- Maha Alafeef
- Department of Chemical, Biochemical and Environmental
Engineering, University of Maryland Baltimore County, Interdisciplinary
Health Sciences Facility, 1000 Hilltop Circle, Baltimore, Maryland 21250,
United States
- Departments of Diagnostic Radiology and Nuclear
Medicine and Pediatrics, Center for Blood Oxygen Transport and Hemostasis,
University of Maryland Baltimore School of Medicine, Health Sciences
Research Facility III, 670 W Baltimore Street, Baltimore, Maryland 21201,
United States
- Department of Bioengineering, the
University of Illinois at Urbana−Champaign, Urbana, Illinois 61801,
United States
- Biomedical Engineering Department, Jordan
University of Science and Technology, Irbid 22110,
Jordan
| | - Dipanjan Pan
- Department of Chemical, Biochemical and Environmental
Engineering, University of Maryland Baltimore County, Interdisciplinary
Health Sciences Facility, 1000 Hilltop Circle, Baltimore, Maryland 21250,
United States
- Departments of Diagnostic Radiology and Nuclear
Medicine and Pediatrics, Center for Blood Oxygen Transport and Hemostasis,
University of Maryland Baltimore School of Medicine, Health Sciences
Research Facility III, 670 W Baltimore Street, Baltimore, Maryland 21201,
United States
- Department of Bioengineering, the
University of Illinois at Urbana−Champaign, Urbana, Illinois 61801,
United States
| |
Collapse
|
20
|
Gajbhiye A, Nalbant A, Heunis T, Sidgwick F, Porter A, Taha Y, Trost M. A fast and sensitive absolute quantification assay for the detection of SARS-CoV-2 peptides using parallel reaction monitoring mass spectrometry. J Proteomics 2022; 265:104664. [PMID: 35732269 PMCID: PMC9212948 DOI: 10.1016/j.jprot.2022.104664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 05/12/2022] [Accepted: 06/12/2022] [Indexed: 12/25/2022]
Abstract
The on-going SARS-CoV-2 (COVID-19) pandemic has called for an urgent need for rapid and high-throughput methods for mass testing and early detection, prevention as well as surveillance of the disease. We investigated whether targeted parallel reaction monitoring (PRM) quantification using high resolution Orbitrap instruments can provide the sensitivity and speed required for a high-throughput method that could be used for clinical diagnosis. We developed a high-throughput and sensitive PRM-MS assay that enables absolute quantification of SARS-CoV-2 nucleocapsid peptides with short turn-around times by using isotopically labelled synthetic SARS-CoV-2 concatenated peptides. We established a fast and high-throughput S-trap-based sample preparation method and utilized it for testing 25 positive and 25 negative heat-inactivated clinical nasopharyngeal swab samples for SARS-CoV-2 detection. The method was able to differentiate between negative and some of the positive patients with high viral load. Moreover, based on the absolute quantification calculations, our data show that patients with Ct values as low as 17.8 correspond to NCAP protein amounts of around 7.5 pmol in swab samples. The present high-throughput method could potentially be utilized in specialized clinics as an alternative tool for detection of SARS-CoV-2 but will require enrichment of viral proteins in order to compete with RT-qPCR.
Collapse
Affiliation(s)
- Akshada Gajbhiye
- Laboratory for Biomedical Mass Spectrometry, Newcastle University, Newcastle upon Tyne, UK
| | - Atakan Nalbant
- Laboratory for Biomedical Mass Spectrometry, Newcastle University, Newcastle upon Tyne, UK
| | - Tiaan Heunis
- Laboratory for Biomedical Mass Spectrometry, Newcastle University, Newcastle upon Tyne, UK
| | - Frances Sidgwick
- Laboratory for Biomedical Mass Spectrometry, Newcastle University, Newcastle upon Tyne, UK
| | - Andrew Porter
- Laboratory for Biomedical Mass Spectrometry, Newcastle University, Newcastle upon Tyne, UK
| | - Yusri Taha
- The Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, Newcastle upon Tyne NE1 4LP, UK
| | - Matthias Trost
- Laboratory for Biomedical Mass Spectrometry, Newcastle University, Newcastle upon Tyne, UK.
| |
Collapse
|
21
|
Nguyen PQM, Wang M, Ann Maria N, Li AY, Tan HY, Xiong GM, Tan MKM, Bhagat AAS, Ong CWM, Lim CT. Modular micro-PCR system for the onsite rapid diagnosis of COVID-19. Microsyst Nanoeng 2022; 8:82. [PMID: 35860034 PMCID: PMC9294789 DOI: 10.1038/s41378-022-00400-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Revised: 04/17/2022] [Accepted: 05/05/2022] [Indexed: 06/15/2023]
Abstract
Effective containment of the COVID-19 pandemic requires rapid and accurate detection of the pathogen. Polymerase chain reaction (PCR) remains the gold standard for COVID-19 confirmation. In this article, we report the performance of a cost-effective modular microfluidic reverse transcription (RT)-PCR and RT-loop mediated isothermal amplification (RT-LAMP) platform, Epidax®, for the point-of-care testing and confirmation of SARS-CoV-2. This platform is versatile and can be reconfigured either for screening using endpoint RT-PCR or RT-LAMP tests or for confirmatory tests using real-time RT-PCR. Epidax® is highly sensitive and detects as little as 1 RNA copy per µL for real-time and endpoint RT-PCR, while using only half of the reagents. We achieved comparable results with those of a commercial platform when detecting SARS-CoV-2 viruses from 81 clinical RNA extracts. Epidax® can also detect SARS-CoV-2 from 44 nasopharyngeal samples without RNA extraction by using a direct RT-PCR assay, which shortens the sample-to-answer time to an hour with minimal user steps. Furthermore, we validated the technology using an RT-LAMP assay on 54 clinical RNA extracts. Overall, our platform provides a sensitive, cost-effective, and accurate diagnostic solution for low-resource settings.
Collapse
Affiliation(s)
- Phuong Quoc Mai Nguyen
- Institute for Health Innovation and Technology (iHealthtech), National University of Singapore, MD6, 14 Medical Drive #14-01, Singapore, 117599 Singapore
- Department of Biomedical Engineering, National University of Singapore, 4 Engineering Drive 3, Block 4, #04-08, Singapore, 117583 Singapore
| | - Ming Wang
- Institute for Health Innovation and Technology (iHealthtech), National University of Singapore, MD6, 14 Medical Drive #14-01, Singapore, 117599 Singapore
| | - Nelisha Ann Maria
- Institute for Health Innovation and Technology (iHealthtech), National University of Singapore, MD6, 14 Medical Drive #14-01, Singapore, 117599 Singapore
| | - Adelicia Yongling Li
- Institute for Health Innovation and Technology (iHealthtech), National University of Singapore, MD6, 14 Medical Drive #14-01, Singapore, 117599 Singapore
| | - Hsih Yin Tan
- Institute for Health Innovation and Technology (iHealthtech), National University of Singapore, MD6, 14 Medical Drive #14-01, Singapore, 117599 Singapore
| | - Gordon Minru Xiong
- Institute for Health Innovation and Technology (iHealthtech), National University of Singapore, MD6, 14 Medical Drive #14-01, Singapore, 117599 Singapore
| | - Meng-Kwang Marcus Tan
- Advanced MedTech, 2 Venture Drive, #23-18 Vision Exchange, Singapore, 608526 Singapore
| | - Ali Asgar S. Bhagat
- Institute for Health Innovation and Technology (iHealthtech), National University of Singapore, MD6, 14 Medical Drive #14-01, Singapore, 117599 Singapore
- Department of Biomedical Engineering, National University of Singapore, 4 Engineering Drive 3, Block 4, #04-08, Singapore, 117583 Singapore
| | - Catherine W. M. Ong
- Institute for Health Innovation and Technology (iHealthtech), National University of Singapore, MD6, 14 Medical Drive #14-01, Singapore, 117599 Singapore
- Infectious Diseases Translational Research Programme, Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, NUHS Tower Block, 1E Kent Ridge Road Level 11, Singapore, 119228 Singapore
| | - Chwee Teck Lim
- Institute for Health Innovation and Technology (iHealthtech), National University of Singapore, MD6, 14 Medical Drive #14-01, Singapore, 117599 Singapore
- Department of Biomedical Engineering, National University of Singapore, 4 Engineering Drive 3, Block 4, #04-08, Singapore, 117583 Singapore
| |
Collapse
|
22
|
Ghorashi MS, Pant SD, Ghorashi SA. Comparison of colourimetric loop-mediated isothermal amplification (LAMP), PCR and high-resolution melt curve analysis and culture based diagnostic assays in the detection of three salmonella serotypes in poultry. Avian Pathol 2022; 51:476-487. [PMID: 35833568 DOI: 10.1080/03079457.2022.2101916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
The accuracy of two molecular tests, PCR and loop-mediated isothermal amplification (LAMP) assay were compared with bacterial culture in detection of salmonella in poultry clinical samples. The icIR family transcriptional regulator gene was targeted and out of 56 clinical specimens, 20 poultry field isolates were found positive for salmonella. Along with human isolates, reference strains of three different serovars, Salmonella Enteritidis (S. Enteritidis), S. Typhimurium and S. Infantis, were also tested. Eight different but genetically closely related bacterial genera (Klebsiella, Pseudomonas, Enterobacter, Campylobacter, Staphylococcus, Streptococcus, Escherichia and Pasteurella) were also used to evaluate the specificity of assay. The LAMP assay showed 80.8% sensitivity (95% CI, 0.66-0.95) and 100% specificity (95% CI, 0.71-1.00) when compared with microbiological culture and PCR, both with 100% sensitivity (95% CI, 0.87-1.00) and 100% specificity (95% CI, 0.71-1.00). High-resolution melt (HRM) curve analysis following PCR was able to differentiate between salmonella isolates based on their melting points, and all specimens were genotyped in three distinct HRM curve profiles. Each normalised melt curve profile represented one salmonella serotype and differences between the three melt profiles were correlated with nucleotide variations in the target gene sequences which demonstrated high discriminatory power of this technique. The colourimetric LAMP assay provided an alternative detection method capable of being used in the field and showed analytical sensitivity for detection of 1 pg of salmonella DNA per reaction. The advantages and disadvantages of each test in detection of salmonella are discussed.
Collapse
Affiliation(s)
- Mojdeh Sadat Ghorashi
- School of Biomedical Sciences, Charles Sturt University, Wagga Wagga, NSW 2678, Australia,
| | - Sameer Dinkar Pant
- School of Agricultural, Environmental and Veterinary Sciences, Charles Sturt University, Wagga Wagga, NSW 2678, Australia: .,Graham Centre for Agricultural Innovation, Wagga Wagga, Australia:
| | - Seyed Ali Ghorashi
- School of Agricultural, Environmental and Veterinary Sciences, Charles Sturt University, Wagga Wagga, NSW 2678, Australia: .,Graham Centre for Agricultural Innovation, Wagga Wagga, Australia:
| |
Collapse
|
23
|
Hong KH, Kim GJ, Roh KH, Sung H, Lee J, Kim SY, Kim TS, Park JS, Huh HJ, Park Y, Kim JS, Kim HS, Seong MW, Ryoo NH, Song SH, Lee H, Kwon GC, Yoo CK. Update of Guidelines for Laboratory Diagnosis of COVID-19 in Korea. Ann Lab Med 2022; 42:391-397. [PMID: 35177559 PMCID: PMC8859556 DOI: 10.3343/alm.2022.42.4.391] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 01/25/2022] [Accepted: 02/07/2022] [Indexed: 11/19/2022] Open
Abstract
Korean Society for Laboratory Medicine and the Korea Disease Prevention and Control Agency have announced guidelines for diagnosing coronavirus disease (COVID-19) in clinical laboratories in Korea. With the ongoing pandemic, we propose an update of the previous guidelines based on new scientific data. This update includes recommendations for tests that were not included in the previous guidelines, including the rapid molecular test, antigen test, antibody test, and self-collected specimens, and a revision of the previous recommendations. This update will aid clinical laboratories in performing laboratory tests for diagnosing COVID-19.
Collapse
Affiliation(s)
- Ki Ho Hong
- Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Gab Jung Kim
- Bureau of Infectious Disease Diagnosis Control, the Korea Disease Control and Prevention Agency, Osong, Korea
| | - Kyoung Ho Roh
- Department of Laboratory Medicine, National Health Insurance Service Ilsan Hospital, Goyang, Korea
| | - Heungsup Sung
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jaehyeon Lee
- Department of Laboratory Medicine, Jeonbuk National University Medical School and Hospital, Jeonju, Korea
| | - So Yeon Kim
- Department of Laboratory Medicine, National Medical Center, Seoul, Korea
| | - Taek Soo Kim
- Department of Laboratory Medicine, Seoul National University Hospital, Seoul, Korea
| | - Jae-Sun Park
- Bureau of Infectious Disease Diagnosis Control, the Korea Disease Control and Prevention Agency, Osong, Korea
| | - Hee Jae Huh
- Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Younhee Park
- Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Jae-Seok Kim
- Department of Laboratory Medicine, Hallym University College of Medicine, Chuncheon, Korea
| | - Hyun Soo Kim
- Department of Laboratory Medicine, Hallym University College of Medicine, Chuncheon, Korea
| | - Moon-Woo Seong
- Department of Laboratory Medicine, Seoul National University Hospital, Seoul, Korea
| | - Nam Hee Ryoo
- Department of Laboratory Medicine, Keimyung University School of Medicine, Daegu, Korea
| | - Sang Hoon Song
- Department of Laboratory Medicine, Seoul National University Hospital, Seoul, Korea
| | - Hyukmin Lee
- Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea
| | - Gye Cheol Kwon
- Department of Laboratory Medicine, College of Medicine, Chungnam National University, Daejeon, Korea
| | - Cheon Kwon Yoo
- Bureau of Infectious Disease Diagnosis Control, the Korea Disease Control and Prevention Agency, Osong, Korea
| | | |
Collapse
|
24
|
Kim HY, Bershteyn A, McGillen JB, Shaff J, Sisti J, Ko C, Wikramanayake R, Newton-Dame R, Braithwaite RS. Social distancing and mask-wearing could avoid recurrent stay-at-home restrictions during COVID-19 respiratory pandemic in New York City. Sci Rep 2022; 12:10312. [PMID: 35725991 DOI: 10.1038/s41598-022-13310-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 05/23/2022] [Indexed: 11/16/2022] Open
Abstract
Stay-at-home restrictions such as closure of non-essential businesses were effective at reducing SARS-CoV-2 transmission in New York City (NYC) in the spring of 2020. Relaxation of these restrictions was desirable for resuming economic and social activities, but could only occur in conjunction with measures to mitigate the expected resurgence of new infections, in particular social distancing and mask-wearing. We projected the impact of individuals’ adherence to social distancing and mask-wearing on the duration, frequency, and recurrence of stay-at-home restrictions in NYC. We applied a stochastic discrete time-series model to simulate community transmission and household secondary transmission in NYC. The model was calibrated to hospitalizations, ICU admissions, and COVID-attributable deaths over March–July 2020 after accounting for the distribution of age and chronic health conditions in NYC. We projected daily new infections and hospitalizations up to May 31, 2021 under the different levels of adherence to social distancing and mask-wearing after relaxation of stay-at-home restrictions. We assumed that the relaxation of stay-at-home policies would occur in the context of adaptive reopening, where a new hospitalization rate of ≥ 2 per 100,000 residents would trigger reinstatement of stay-at-home restrictions while a new hospitalization rate of ≤ 0.8 per 100,000 residents would trigger relaxation of stay-at-home restrictions. Without social distancing and mask-wearing, simulated relaxation of stay-at-home restrictions led to epidemic resurgence and necessary reinstatement of stay-at-home restrictions within 42 days. NYC would have stayed fully open for 26% of the time until May 31, 2021, alternating reinstatement and relaxation of stay-at-home restrictions in four cycles. At a low (50%) level of adherence to mask-wearing, NYC would have needed to implement stay-at-home restrictions between 8% and 32% of the time depending on individual adherence to social distancing. At moderate to high levels of adherence to mask-wearing without social distancing, NYC would have needed to implement stay-at-home restrictions. In threshold analyses, avoiding reinstatement of stay-at-home restrictions required a minimum of 60% adherence to mask-wearing at 50% adherence to social distancing. With low adherence to mask-wearing and social distancing, reinstatement of stay-at-home restrictions in NYC was inevitable. High levels of adherence to social distancing and mask-wearing could have attributed to avoiding recurrent surges without reinstatement of stay-at-home restrictions.
Collapse
|
25
|
Rotondo JC, Martini F, Maritati M, Caselli E, Gallenga CE, Guarino M, De Giorgio R, Mazziotta C, Tramarin ML, Badiale G, Tognon M, Contini C. Advanced Molecular and Immunological Diagnostic Methods to Detect SARS-CoV-2 Infection. Microorganisms 2022; 10:1193. [PMID: 35744711 PMCID: PMC9231257 DOI: 10.3390/microorganisms10061193] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/06/2022] [Accepted: 06/06/2022] [Indexed: 02/06/2023] Open
Abstract
COVID-19 emerged in late 2019 in China and quickly spread across the globe, causing over 521 million cases of infection and 6.26 million deaths to date. After 2 years, numerous advances have been made. First of all, the preventive vaccine, which has been implemented in record time, is effective in more than 95% of cases. Additionally, in the diagnostic field, there are numerous molecular and antigenic diagnostic kits that are equipped with high sensitivity and specificity. Real Time-PCR-based assays for the detection of viral RNA are currently considered the gold-standard method for SARS-CoV-2 diagnosis and can be used efficiently on pooled nasopharyngeal, or oropharyngeal samples for widespread screening. Moreover, additional, and more advanced molecular methods such as droplet-digital PCR (ddPCR), clustered regularly interspaced short palindromic repeats (CRISPR) and next-generation sequencing (NGS), are currently under development to detect the SARS-CoV-2 RNA. However, as the number of subjects infected with SARS-CoV-2 continuously increases globally, health care systems are being placed under increased stress. Thus, the clinical laboratory plays an important role, helping to select especially asymptomatic individuals who are actively carrying the live replicating virus, with fast and non-invasive molecular technologies. Recent diagnostic strategies, other than molecular methods, have been adopted to either detect viral antigens, i.e., antigen-based immunoassays, or human anti-SARS-CoV-2 antibodies, i.e., antibody-based immunoassays, in nasal or oropharyngeal swabs, as well as in blood or saliva samples. However, the role of mucosal sIgAs, which are essential in the control of viruses entering the body through mucosal surfaces, remains to be elucidated, and in particular the role of the immune response in counteracting SARS-CoV-2 infection, primarily at the site(s) of virus entry that appears to be promising.
Collapse
Affiliation(s)
- John Charles Rotondo
- Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy; (F.M.); (M.M.); (C.E.G.); (C.M.); (M.L.T.); (G.B.); (M.T.)
- Center for Studies on Gender Medicine, Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy
| | - Fernanda Martini
- Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy; (F.M.); (M.M.); (C.E.G.); (C.M.); (M.L.T.); (G.B.); (M.T.)
- Center for Studies on Gender Medicine, Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy
- Laboratory for Technologies of Advanced Therapies (LTTA), University of Ferrara, 44121 Ferrara, Italy
| | - Martina Maritati
- Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy; (F.M.); (M.M.); (C.E.G.); (C.M.); (M.L.T.); (G.B.); (M.T.)
- Orthopaedic Ward, Casa di Cura Santa Maria Maddalena, 45030 Occhiobello, Italy
| | - Elisabetta Caselli
- Section of Microbiology, CIAS Research Center and LTTA, Department of Chemical, Pharmaceutical and Agricultural Sciences, University of Ferrara, 44121 Ferrara, Italy;
| | - Carla Enrica Gallenga
- Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy; (F.M.); (M.M.); (C.E.G.); (C.M.); (M.L.T.); (G.B.); (M.T.)
| | - Matteo Guarino
- Department of Translational Medicine, St. Anna University Hospital of Ferrara, University of Ferrara, 44124 Ferrara, Italy; (M.G.); (R.D.G.)
| | - Roberto De Giorgio
- Department of Translational Medicine, St. Anna University Hospital of Ferrara, University of Ferrara, 44124 Ferrara, Italy; (M.G.); (R.D.G.)
| | - Chiara Mazziotta
- Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy; (F.M.); (M.M.); (C.E.G.); (C.M.); (M.L.T.); (G.B.); (M.T.)
- Center for Studies on Gender Medicine, Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy
| | - Maria Letizia Tramarin
- Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy; (F.M.); (M.M.); (C.E.G.); (C.M.); (M.L.T.); (G.B.); (M.T.)
| | - Giada Badiale
- Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy; (F.M.); (M.M.); (C.E.G.); (C.M.); (M.L.T.); (G.B.); (M.T.)
| | - Mauro Tognon
- Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy; (F.M.); (M.M.); (C.E.G.); (C.M.); (M.L.T.); (G.B.); (M.T.)
| | - Carlo Contini
- Department of Medical Sciences, University of Ferrara, 44121 Ferrara, Italy; (F.M.); (M.M.); (C.E.G.); (C.M.); (M.L.T.); (G.B.); (M.T.)
| |
Collapse
|
26
|
Dewhurst RE, Heinrich T, Watt P, Ostergaard P, Marimon JM, Moreira M, Houldsworth PE, Rudrum JD, Wood D, Kõks S. Validation of a rapid, saliva-based, and ultra-sensitive SARS-CoV-2 screening system for pandemic-scale infection surveillance. Sci Rep 2022; 12:5936. [PMID: 35395856 PMCID: PMC8990279 DOI: 10.1038/s41598-022-08263-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Accepted: 03/02/2022] [Indexed: 12/23/2022] Open
Abstract
Without any realistic prospect of comprehensive global vaccine coverage and lasting immunity, control of pandemics such as COVID-19 will require implementation of large-scale, rapid identification and isolation of infectious individuals to limit further transmission. Here, we describe an automated, high-throughput integrated screening platform, incorporating saliva-based loop-mediated isothermal amplification (LAMP) technology, that is designed for population-scale sensitive detection of infectious carriers of SARS-CoV-2 RNA. Central to this surveillance system is the "Sentinel" testing instrument, which is capable of reporting results within 25 min of saliva sample collection with a throughput of up to 3840 results per hour. It incorporates continuous flow loading of samples at random intervals to cost-effectively adjust for fluctuations in testing demand. Independent validation of our saliva-based RT-LAMP technology on an automated LAMP instrument coined the "Sentinel", found 98.7% sensitivity, 97.6% specificity, and 98% accuracy against a RT-PCR comparator assay, confirming its suitability for surveillance screening. This Sentinel surveillance system offers a feasible and scalable approach to complement vaccination, to curb the spread of COVID-19 variants, and control future pandemics to save lives.
Collapse
Affiliation(s)
- Robert E Dewhurst
- Perron Institute for Neurological and Translational Science, Perth, WA, 6009, Australia
- Avicena Systems Ltd, West Perth, WA, 6005, Australia
| | - Tatjana Heinrich
- Perron Institute for Neurological and Translational Science, Perth, WA, 6009, Australia
- Avicena Systems Ltd, West Perth, WA, 6005, Australia
| | - Paul Watt
- Avicena Systems Ltd, West Perth, WA, 6005, Australia
- Telethon Kids Institute, University of Western Australia, Perth, WA, 6009, Australia
| | | | - Jose M Marimon
- Biodonostia Health Research Institute, Infectious Diseases Area, Osakidetza Basque Health Service, Donostialdea Integrated Health Organization, San Sebastián, Spain
| | - Mariana Moreira
- Lancs Lamp Laboratory, Heatley House, Bowran Street, Preston, PR1 2UX, UK
| | | | - Jack D Rudrum
- Perron Institute for Neurological and Translational Science, Perth, WA, 6009, Australia
- Avicena Systems Ltd, West Perth, WA, 6005, Australia
| | - David Wood
- University of Western Australia, Perth, WA, 6009, Australia
| | - Sulev Kõks
- Perron Institute for Neurological and Translational Science, Perth, WA, 6009, Australia.
- Centre for Molecular Medicine and Innovative Therapeutics, Murdoch University, Perth, WA, 6150, Australia.
- Prion Ltd, 50410, Tartu, Estonia.
| |
Collapse
|
27
|
Papadakis G, Pantazis AK, Fikas N, Chatziioannidou S, Tsiakalou V, Michaelidou K, Pogka V, Megariti M, Vardaki M, Giarentis K, Heaney J, Nastouli E, Karamitros T, Mentis A, Zafiropoulos A, Sourvinos G, Agelaki S, Gizeli E. Portable real-time colorimetric LAMP-device for rapid quantitative detection of nucleic acids in crude samples. Sci Rep 2022; 12:3775. [PMID: 35260588 PMCID: PMC8904468 DOI: 10.1038/s41598-022-06632-7] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 01/27/2022] [Indexed: 02/08/2023] Open
Abstract
Loop-mediated isothermal amplification is known for its high sensitivity, specificity and tolerance to inhibiting-substances. In this work, we developed a device for performing real-time colorimetric LAMP combining the accuracy of lab-based quantitative analysis with the simplicity of point-of-care testing. The device innovation lies on the use of a plastic tube anchored vertically on a hot surface while the side walls are exposed to a mini camera able to take snapshots of the colour change in real time during LAMP amplification. Competitive features are the rapid analysis (< 30 min), quantification over 9 log-units, crude sample-compatibility (saliva, tissue, swabs), low detection limit (< 5 copies/reaction), smartphone-operation, fast prototyping (3D-printing) and ability to select the dye of interest (Phenol red, HNB). The device’s clinical utility is demonstrated in cancer mutations-analysis during the detection of 0.01% of BRAF-V600E-to-wild-type molecules from tissue samples and COVID-19 testing with 97% (Ct < 36.8) and 98% (Ct < 30) sensitivity when using extracted RNA and nasopharyngeal-swabs, respectively. The device high technology-readiness-level makes it a suitable platform for performing any colorimetric LAMP assay; moreover, its simple and inexpensive fabrication holds promise for fast deployment and application in global diagnostics.
Collapse
Affiliation(s)
- G Papadakis
- Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, 100 N. Plastira Str., 70013, Heraklion, Greece. .,BIOPIX DNA TECHNOLOGY PC, Science and Technology Park of Crete, 100 N. Plastira Str., 70013, Heraklion, Greece.
| | - A K Pantazis
- Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, 100 N. Plastira Str., 70013, Heraklion, Greece.,BIOPIX DNA TECHNOLOGY PC, Science and Technology Park of Crete, 100 N. Plastira Str., 70013, Heraklion, Greece
| | - N Fikas
- Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, 100 N. Plastira Str., 70013, Heraklion, Greece.,BIOPIX DNA TECHNOLOGY PC, Science and Technology Park of Crete, 100 N. Plastira Str., 70013, Heraklion, Greece
| | - S Chatziioannidou
- Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, 100 N. Plastira Str., 70013, Heraklion, Greece.,BIOPIX DNA TECHNOLOGY PC, Science and Technology Park of Crete, 100 N. Plastira Str., 70013, Heraklion, Greece.,Department of Biology, University of Crete, 70013, Voutes, Heraklion, Greece
| | - V Tsiakalou
- Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, 100 N. Plastira Str., 70013, Heraklion, Greece
| | - K Michaelidou
- Laboratory of Translational Oncology, School of Medicine, University of Crete, 71500, Heraklion, Greece
| | - V Pogka
- National SARS-CoV-2 Reference Laboratory, Hellenic Pasteur Institute, 127 Vas. Sofias Ave., 11521, Athens, Greece
| | - M Megariti
- Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, 100 N. Plastira Str., 70013, Heraklion, Greece
| | - M Vardaki
- Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, 100 N. Plastira Str., 70013, Heraklion, Greece.,Department of Biology, University of Crete, 70013, Voutes, Heraklion, Greece
| | - K Giarentis
- Department of Biology, University of Crete, 70013, Voutes, Heraklion, Greece
| | - J Heaney
- Advanced Pathogens Diagnostics Unit, University College London Hospitals NHS Trust, London, WC1H 9AX, UK.,UCL Great Ormond Street Institute of Child Health, London, UK
| | - E Nastouli
- Advanced Pathogens Diagnostics Unit, University College London Hospitals NHS Trust, London, WC1H 9AX, UK.,UCL Great Ormond Street Institute of Child Health, London, UK
| | - T Karamitros
- National SARS-CoV-2 Reference Laboratory, Hellenic Pasteur Institute, 127 Vas. Sofias Ave., 11521, Athens, Greece
| | - A Mentis
- National SARS-CoV-2 Reference Laboratory, Hellenic Pasteur Institute, 127 Vas. Sofias Ave., 11521, Athens, Greece
| | - A Zafiropoulos
- Laboratory of Clinical Virology, School of Medicine, University of Crete, 71500, Heraklion, Greece
| | - G Sourvinos
- Laboratory of Clinical Virology, School of Medicine, University of Crete, 71500, Heraklion, Greece
| | - S Agelaki
- Department of Biology, University of Crete, 70013, Voutes, Heraklion, Greece.,Department of Medical Oncology, University General Hospital, 71110, Heraklion, Greece
| | - E Gizeli
- Institute of Molecular Biology and Biotechnology, Foundation for Research and Technology-Hellas, 100 N. Plastira Str., 70013, Heraklion, Greece. .,Department of Biology, University of Crete, 70013, Voutes, Heraklion, Greece.
| |
Collapse
|
28
|
Bhatt A, Bumbrah GS, Ruwali M, Hameed S, Fatima Z. Diagnostic efficiency of RT-LAMP integrated CRISPR-Cas technique for COVID-19: A systematic review and meta-analysis. Pathog Glob Health 2022; 116:410-420. [PMID: 35142264 PMCID: PMC8862172 DOI: 10.1080/20477724.2022.2035625] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
To address the challenges associated with COVID-19 diagnosis, we need a faster, direct, and more versatile detection method for efficient epidemiological management of the COVID-19 pandemic. RT-qPCR (reverse transcription quantitative real-time Polymerase Chain Reaction) although the most popular diagnostic method suffers from a major drawback of equipment dependency and trained molecular biologists that limits rapid and large-scale screening, particularly in low resource regions. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a feasible alternative for RT-qPCR; however, it also suffers from the drawback of false-positive issues. Recently, RT-LAMP has been integrated with the CRISPR-Cas technique to take care of the problems associated with RT-LAMP for COVID-19 diagnosis. In this study, a meta-analysis was conducted using three scientific databases considering the PRISMA guidelines to assess the diagnostic efficiency of RT-LAMP integrated CRISPR-Cas technology. Out of a total of 1286 studies on COVID-19, we identified 15 articles that met our eligibility criteria of using simultaneous RT-LAMP and CRISPR-Cas technique. Our meta-analysis of the included studies revealed that most of the studies were conducted in the USA with the N gene as the most common target and fluorescence-based detection method. The meta-analysis results of all included studies have further revealed a pooled sensitivity value of higher than 85% and a pooled specificity value of 80% with the confidence interval of 95%, respectively, as revealed from the forest plot and SROC curve. The accuracy rate of included studies was also calculated which varied from 77.4% to 100%. Furthermore, the precision of included studies varied from 75% to 100%. Lastly, a quality assessment of bias and applicability was performed based on QUADAS-2. Taken together, combined RT-LAMP and CRISPR-Cas technique could be a potential alternative to RT-qPCR particularly in low resource regions having a high demand for rapid testing.
Collapse
Affiliation(s)
- Akansha Bhatt
- Amity Institute of Biotechnology, Amity University Haryana, Gurugram, India
| | - Gurvinder Singh Bumbrah
- Department of Forensic Sciences, Amity School of Applied Sciences, Amity University Haryana, Gurugram, India
| | - Munindra Ruwali
- Amity Institute of Biotechnology, Amity University Haryana, Gurugram, India
| | - Saif Hameed
- Amity Institute of Biotechnology, Amity University Haryana, Gurugram, India
| | - Zeeshan Fatima
- Amity Institute of Biotechnology, Amity University Haryana, Gurugram, India
| |
Collapse
|
29
|
Pu R, Liu S, Ren X, Shi D, Ba Y, Huo Y, Zhang W, Ma L, Liu Y, Yang Y, Cheng N. The screening value of RT-LAMP and RT-PCR in the diagnosis of COVID-19: systematic review and meta-analysis. J Virol Methods 2022; 300:114392. [PMID: 34856308 PMCID: PMC8629515 DOI: 10.1016/j.jviromet.2021.114392] [Citation(s) in RCA: 48] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 11/28/2021] [Accepted: 11/28/2021] [Indexed: 02/08/2023]
Abstract
The purpose of this systematic review is to evaluate the test accuracy of reverse-transcription loop-mediated isothermal amplification (RT-LAMP) and reverse transcription-PCR (RT-PCR) for the diagnosis of coronavirus disease 2019 (COVID-19). We comprehensively searched PUBMED, Web of Science, the Cochrane Library, the Chinese National Knowledge Infrastructure, and the Chinese Biomedical Literature Service System until September 1, 2021. We included clinical studies assessing the sensitivity and specificity of RT-PCR and RT-LAMP using respiratory samples. Thirty-three studies were included with 9360 suspected cases of SARS-CoV-2 infection. The RT-PCR or other comprehensive diagnostic method was defined as the reference method. The results showed that the overall pooled sensitivity of RT-PCR and RT-LAMP was 0.96 (95 % CI, 0.93-0.98) and 0.92 (95 % CI, 0.85-0.96), respectively. RT-PCR and RT-LAMP had a 0.06 (95 % CI, 0.04-0.08) and 0.12 (95 % CI, 0.06-0.16) false-negative rates (FNR), respectively. Moreover, subgroup analysis showed mixed sampling and multiple target gene diagnosis methods had better diagnostic value than single-site sampling and a single target gene. The sensitivity and FNR were also significantly affected by the reference method. Comparing RT-LAMP with established suboptimal RT-PCR may exaggerate the performance of RT-LAMP. RT-PCR and RT-LAMP showed high values in the diagnosis of COVID-19, but there was still a FNR of about 6%-12%.
Collapse
Affiliation(s)
- Ruiyang Pu
- School of Basic Medical Sciences, Lanzhou University, Lanzhou, Gansu, PR China
| | - Sha Liu
- School of Basic Medical Sciences, Lanzhou University, Lanzhou, Gansu, PR China
| | - Xiaoyu Ren
- School of Basic Medical Sciences, Lanzhou University, Lanzhou, Gansu, PR China
| | - Dian Shi
- School of Basic Medical Sciences, Lanzhou University, Lanzhou, Gansu, PR China
| | - Yupei Ba
- Institute of Epidemiology and Statistics, School of Public Health, Lanzhou University, Lanzhou, Gansu, PR China
| | - Yanbei Huo
- Institute of Epidemiology and Statistics, School of Public Health, Lanzhou University, Lanzhou, Gansu, PR China
| | - Wenling Zhang
- Institute of Epidemiology and Statistics, School of Public Health, Lanzhou University, Lanzhou, Gansu, PR China
| | - Lingling Ma
- School of Basic Medical Sciences, Lanzhou University, Lanzhou, Gansu, PR China
| | - Yanyan Liu
- Institute of Epidemiology and Statistics, School of Public Health, Lanzhou University, Lanzhou, Gansu, PR China
| | - Yan Yang
- School of Basic Medical Sciences, Lanzhou University, Lanzhou, Gansu, PR China
| | - Ning Cheng
- School of Basic Medical Sciences, Lanzhou University, Lanzhou, Gansu, PR China.
| |
Collapse
|
30
|
Farrera-Soler L, Gonse A, Kim KT, Barluenga S, Winssinger N. Combining recombinase polymerase amplification and DNA-templated reaction for SARS-CoV-2 sensing with dual fluorescence and lateral flow assay output. Biopolymers 2022; 113:e23485. [PMID: 35023571 PMCID: PMC9011641 DOI: 10.1002/bip.23485] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 12/17/2021] [Accepted: 12/20/2021] [Indexed: 12/17/2022]
Abstract
The early phase of the severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) pandemic was exacerbated by a diagnostic challenge of unprecedented magnitude. In the absence of effective therapeutics or vaccines, breaking the chain of transmission through early disease detection and patient isolation was the only means to control the growing pandemic. While polymerase chain reaction (PCR)‐based methods and rapid‐antigen tests rose to the occasion, the analytical challenge of rapid and sequence‐specific nucleic acid‐sensing at a point‐of‐care or home setting stimulated intense developments. Herein we report a method that combines recombinase polymerase amplification and a DNA‐templated reaction to achieve a dual readout with either fluorescence (microtiter plate) or naked eye (lateral flow assay: LFA) detection. The nucleic acid templated reaction is based on an SNAr that simultaneously transfers biotin from one Peptide Nucleic Acid (PNA) strand to another PNA strand, enabling LFA detection while uncaging a coumarin for fluorescence readout. This methodology has been applied to the detection of a DNA or RNA sequence uniquely attributed to the SARS‐CoV‐2.
Collapse
Affiliation(s)
- Lluc Farrera-Soler
- Department of Organic Chemistry, NCCR Chemical Biology, Faculty of Science, University of Geneva, Geneva, Switzerland
| | - Arthur Gonse
- Department of Organic Chemistry, NCCR Chemical Biology, Faculty of Science, University of Geneva, Geneva, Switzerland
| | - Ki Tae Kim
- Department of Organic Chemistry, NCCR Chemical Biology, Faculty of Science, University of Geneva, Geneva, Switzerland
| | - Sofia Barluenga
- Department of Organic Chemistry, NCCR Chemical Biology, Faculty of Science, University of Geneva, Geneva, Switzerland
| | - Nicolas Winssinger
- Department of Organic Chemistry, NCCR Chemical Biology, Faculty of Science, University of Geneva, Geneva, Switzerland
| |
Collapse
|
31
|
García-Bernalt Diego J, Fernández-Soto P, Muñoz-Bellido JL, Febrer-Sendra B, Crego-Vicente B, Carbonell C, López-Bernús A, Marcos M, Belhassen-García M, Muro A. Detection of SARS-CoV-2 RNA in Urine by RT-LAMP: A Very Rare Finding. J Clin Med 2021; 11:158. [PMID: 35011899 PMCID: PMC8745354 DOI: 10.3390/jcm11010158] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Accepted: 12/27/2021] [Indexed: 01/08/2023] Open
Abstract
Detection of SARS-CoV-2 is routinely performed in naso/oropharyngeal swabs samples from patients via RT-qPCR. The RT-LAMP technology has also been used for viral RNA detection in respiratory specimens with both high sensitivity and specificity. Recently, we developed a novel RT-LAMP test for SARS-CoV-2 RNA detection in nasopharyngeal swab specimens (named, N15-RT-LAMP) that can be performed as a single-tube colorimetric method, in a real-time platform, and as dry-LAMP. To date, there has been very little success in detecting SARS-CoV-2 RNA in urine by RT-qPCR, and the information regarding urine viral excretion is still scarce and not comprehensive. Here, we tested our N15-RT-LAMP on the urine of 300 patients admitted to the Hospital of Salamanca, Spain with clinical suspicion of COVID-19, who had a nasopharyngeal swab RT-qPCR-positive (n = 100), negative (n = 100), and positive with disease recovery (n = 100) result. The positive group was also tested by RT-qPCR for comparison to N15-RT-LAMP. Only a 4% positivity rate was found in the positive group via colorimetric N15-RT-LAMP and 2% via RT-qPCR. Our results are consistent with those obtained in other studies that the presence of SARS-CoV-2 RNA in urine is a very rare finding. The absence of SARS-CoV-2 RNA in urine in the recovered patients might suggest that the urinary route is very rarely used for viral particle clearance.
Collapse
Affiliation(s)
- Juan García-Bernalt Diego
- Infectious and Tropical Diseases Research Group (e-INTRO), Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Biomedical Research Institute of Salamanca, Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (J.G.-B.D.); (B.F.-S.); (B.C.-V.); (C.C.); (A.L.-B.); (M.B.-G.)
| | - Pedro Fernández-Soto
- Infectious and Tropical Diseases Research Group (e-INTRO), Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Biomedical Research Institute of Salamanca, Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (J.G.-B.D.); (B.F.-S.); (B.C.-V.); (C.C.); (A.L.-B.); (M.B.-G.)
| | - Juan Luis Muñoz-Bellido
- Microbiology and Parasitology Service, Complejo Asistencial Universitario de Salamanca (CAUSA), University of Salamanca, 37007 Salamanca, Spain;
| | - Begoña Febrer-Sendra
- Infectious and Tropical Diseases Research Group (e-INTRO), Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Biomedical Research Institute of Salamanca, Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (J.G.-B.D.); (B.F.-S.); (B.C.-V.); (C.C.); (A.L.-B.); (M.B.-G.)
| | - Beatriz Crego-Vicente
- Infectious and Tropical Diseases Research Group (e-INTRO), Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Biomedical Research Institute of Salamanca, Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (J.G.-B.D.); (B.F.-S.); (B.C.-V.); (C.C.); (A.L.-B.); (M.B.-G.)
| | - Cristina Carbonell
- Infectious and Tropical Diseases Research Group (e-INTRO), Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Biomedical Research Institute of Salamanca, Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (J.G.-B.D.); (B.F.-S.); (B.C.-V.); (C.C.); (A.L.-B.); (M.B.-G.)
- Internal Medicine Service, Unidad de Enfermedades Infecciosas, Complejo Asistencial Universitario de Salamanca (CAUSA), University of Salamanca, 37007 Salamanca, Spain;
| | - Amparo López-Bernús
- Infectious and Tropical Diseases Research Group (e-INTRO), Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Biomedical Research Institute of Salamanca, Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (J.G.-B.D.); (B.F.-S.); (B.C.-V.); (C.C.); (A.L.-B.); (M.B.-G.)
- Internal Medicine Service, Unidad de Enfermedades Infecciosas, Complejo Asistencial Universitario de Salamanca (CAUSA), University of Salamanca, 37007 Salamanca, Spain;
| | - Miguel Marcos
- Internal Medicine Service, Unidad de Enfermedades Infecciosas, Complejo Asistencial Universitario de Salamanca (CAUSA), University of Salamanca, 37007 Salamanca, Spain;
| | - Moncef Belhassen-García
- Infectious and Tropical Diseases Research Group (e-INTRO), Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Biomedical Research Institute of Salamanca, Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (J.G.-B.D.); (B.F.-S.); (B.C.-V.); (C.C.); (A.L.-B.); (M.B.-G.)
- Internal Medicine Service, Unidad de Enfermedades Infecciosas, Complejo Asistencial Universitario de Salamanca (CAUSA), University of Salamanca, 37007 Salamanca, Spain;
| | - Antonio Muro
- Infectious and Tropical Diseases Research Group (e-INTRO), Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Biomedical Research Institute of Salamanca, Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (J.G.-B.D.); (B.F.-S.); (B.C.-V.); (C.C.); (A.L.-B.); (M.B.-G.)
| |
Collapse
|
32
|
Domnich A, Orsi A, Panatto D, De Pace V, Ricucci V, Caligiuri P, Guarona G, Chessa V, Ferone D, Boccotti S, Bruzzone B, Icardi G. Comparative Diagnostic Performance of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Kit for the Rapid Detection of SARS-CoV-2. Pathogens 2021; 10:1629. [PMID: 34959584 PMCID: PMC8706056 DOI: 10.3390/pathogens10121629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 12/09/2021] [Accepted: 12/14/2021] [Indexed: 11/30/2022] Open
Abstract
Although the reverse transcription-polymerase chain reaction (RT-PCR) is considered a standard-of-care assay for the laboratory diagnosis of SARS-CoV-2, several limitations of this method have been described. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is an alternative molecular assay and is potentially able to overcome some intrinsic shortcomings of RT-PCR. In this study, we evaluated the diagnostic performance of the novel HG COVID-19 RT-LAMP assay. In this retrospective analysis, a total of 400 routinely collected leftover nasopharyngeal samples with a known RT-PCR result were tested by means of the HG COVID-19 RT-LAMP assay. The overall sensitivity and specificity values of HG COVID-19 RT-LAMP versus RT-PCR were 97.0% (95% CI: 93.6-98.9%) and 98.5% (95% CI: 95.7-99.7%), respectively. Inter-assay agreement was almost perfect (κ = 0.96). Concordance was perfect in samples with high viral loads (cycle threshold < 30). The average time to a positive result on RT-LAMP was 17 min. HG COVID-19 RT-LAMP is a reliable molecular diagnostic kit for detecting SARS-CoV-2, and its performance is comparable to that of RT-PCR. Shorter turnaround times and the possibility of performing molecular diagnostics in the point-of-care setting make it a valuable option for facilities without sophisticated laboratory equipment.
Collapse
Affiliation(s)
- Alexander Domnich
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (A.O.); (V.D.P.); (V.R.); (P.C.); (G.G.); (V.C.); (S.B.); (B.B.); (G.I.)
| | - Andrea Orsi
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (A.O.); (V.D.P.); (V.R.); (P.C.); (G.G.); (V.C.); (S.B.); (B.B.); (G.I.)
- Department of Health Sciences, University of Genoa, 16132 Genoa, Italy;
| | - Donatella Panatto
- Department of Health Sciences, University of Genoa, 16132 Genoa, Italy;
| | - Vanessa De Pace
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (A.O.); (V.D.P.); (V.R.); (P.C.); (G.G.); (V.C.); (S.B.); (B.B.); (G.I.)
| | - Valentina Ricucci
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (A.O.); (V.D.P.); (V.R.); (P.C.); (G.G.); (V.C.); (S.B.); (B.B.); (G.I.)
| | - Patrizia Caligiuri
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (A.O.); (V.D.P.); (V.R.); (P.C.); (G.G.); (V.C.); (S.B.); (B.B.); (G.I.)
| | - Giulia Guarona
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (A.O.); (V.D.P.); (V.R.); (P.C.); (G.G.); (V.C.); (S.B.); (B.B.); (G.I.)
| | - Valerio Chessa
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (A.O.); (V.D.P.); (V.R.); (P.C.); (G.G.); (V.C.); (S.B.); (B.B.); (G.I.)
| | - Diego Ferone
- Department of Internal Medicine and Medical Specialties, University of Genoa, 16132 Genoa, Italy;
- Endocrinology Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy
| | - Simona Boccotti
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (A.O.); (V.D.P.); (V.R.); (P.C.); (G.G.); (V.C.); (S.B.); (B.B.); (G.I.)
- Department of Health Sciences, University of Genoa, 16132 Genoa, Italy;
| | - Bianca Bruzzone
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (A.O.); (V.D.P.); (V.R.); (P.C.); (G.G.); (V.C.); (S.B.); (B.B.); (G.I.)
| | - Giancarlo Icardi
- Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy; (A.O.); (V.D.P.); (V.R.); (P.C.); (G.G.); (V.C.); (S.B.); (B.B.); (G.I.)
- Department of Health Sciences, University of Genoa, 16132 Genoa, Italy;
| |
Collapse
|
33
|
Goupil-Sormany I, Longtin J, Dumaresq J, Jacob-Wagner M, Bouchard F, Romero L, Harvey J, Bestman-Smith J, Provençal M, Beauchemin S, Richard V, Labbé AC. The PRONTO study: Clinical performance of ID NOW in individuals with compatible SARS-CoV-2 symptoms in walk-in centres-accelerated turnaround time for contact tracing. Can Commun Dis Rep 2021; 47:534-42. [PMID: 35018141 DOI: 10.14745/ccdr.v47i12a04] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Background This PRONTO study investigated the clinical performance of the Abbott ID NOWTM (IDN) COVID-19 diagnostic assay used at point of care and its impact on turnaround time for divulgation of test results. Methods Prospective study conducted from December 2020 to February 2021 in acute symptomatic participants presenting in three walk-in centres in the province of Québec. Results Valid paired samples were obtained from 2,372 participants. A positive result on either the IDN or the standard-of-care nucleic acid amplification test (SOC-NAAT) was obtained in 423 participants (prevalence of 17.8%). Overall sensitivity of IDN and SOC-NAAT were 96.4% (95% CI: 94.2-98.0%) and 99.1% (95% CI: 97.6-99.8), respectively; negative predictive values were 99.2% (95% CI: 98.7-99.6%) and 99.8% (95% CI: 99.5-100%), respectively. Turnaround time for positive results was significantly faster on IDN. Conclusion In our experience, IDN use in symptomatic individuals in walk-in centres is a reliable sensitive alternative to SOC-NAAT without the need for subsequent confirmation of negative results. Such deployment can accelerate contact tracing, reduce the burden on laboratories and increase access to testing.
Collapse
|
34
|
Promlek T, Thanunchai M, Phumisantiphong U, Hansirisathit T, Phuttanu C, Dongphooyao S, Thongsopa W, Nuchnoi P. Performance of colorimetric RT-LAMP as a diagnostic tool for SARS-CoV-2 infection during the fourth wave of COVID-19 in Thailand. Int J Infect Dis 2021; 116:133-137. [PMID: 34958929 PMCID: PMC8709723 DOI: 10.1016/j.ijid.2021.12.351] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 12/20/2021] [Accepted: 12/20/2021] [Indexed: 11/27/2022] Open
Abstract
Background COVID-19, which is caused by SARS-CoV-2 and its variants, poses an ongoing global threat, particularly in low-immunization coverage regions. Thus, rapid, accurate, and easy-to-perform diagnostic methods are in urgent demand to halt the spread of the virus. Objectives We aimed to validate the clinical performance of the FastProof 30 min-TTR SARS-CoV-2 reverse transcription loop-mediated isothermal amplification (RT-LAMP) method using leftover RNA samples extracted from 315 nasopharyngeal swabs. The sensitivity and specificity of RT-LAMP were determined in comparison with reverse transcriptase–polymerase chain reaction (RT-PCR). Results Of 315 nasopharyngeal swabs, viral RNA was detected in 154 samples (48.9%) by RT-PCR assay. Compared with RT-PCR, overall sensitivity and specificity of RT-LAMP were 81.82% (95% CI: 74.81–87.57) and 100% (95% CI: 97.73–100), respectively. A 100% positivity rate was achieved in samples with cycle threshold (Ct) <31 for RT-PCR targeting the ORF1ab gene. However, samples with Ct >31 accounted for false-negative results by RT-LAMP in 28 samples. Conclusions RT-LAMP reliably detected viral RNA with high sensitivity and specificity and has potential application for mass screening of patients with acute COVID-19 infection when viral load is high.
Collapse
Affiliation(s)
- Thanyarat Promlek
- Department of Clinical Pathology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand.
| | - Maytawan Thanunchai
- Department of Clinical Pathology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Uraporn Phumisantiphong
- Department of Clinical Pathology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Tonsan Hansirisathit
- Department of Central Laboratory, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Chayanit Phuttanu
- Department of Central Laboratory, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Sunisa Dongphooyao
- Department of Central Laboratory, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Wipawee Thongsopa
- Department of Central Laboratory, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Pornlada Nuchnoi
- Center for Research and Innovation, Faculty of Medical Technology, Mahidol University, Bangkok, Thailand
| |
Collapse
|
35
|
Au WY, Cheung PPH. Diagnostic performances of common nucleic acid tests for SARS-CoV-2 in hospitals and clinics: a systematic review and meta-analysis. Lancet Microbe 2021; 2:e704-e714. [PMID: 34661181 PMCID: PMC8510644 DOI: 10.1016/s2666-5247(21)00214-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND An optimised standard experimental setup across different hospitals is urgently needed to ensure consistency in nucleic acid test results for SARS-CoV-2 detection. A standard comparison across different nucleic acid tests and their optimal experimental setups is not present. We assessed the performance of three common nucleic acid tests, namely digital PCR (dPCR), quantitative PCR (qPCR), and loop-mediated isothermal amplification (LAMP), to detect SARS-CoV-2 in clinical settings. METHODS In this systematic review and meta-analysis we compared sensitivity and specificity of qPCR, dPCR, and LAMP and their performances when different experimental setups (namely specimen type used, use of RNA extraction, primer-probe sets, and RNA extraction methods) are applied. We searched PubMed, BioRxiv, MedRxiv, SciFinder, and ScienceDirect for studies and preprints published between Feb 29 and Dec 15, 2020. Included dPCR, qPCR, and LAMP studies using any type of human specimens should report the number of true-positive, true-negative, false-positive, and false-negative cases with Emergency Use Authorization (EUA)-approved PCR assays as the comparator. Studies with a sample size of less than ten, descriptive studies, case studies, reviews, and duplicated studies were excluded. Pooled sensitivity and specificity were computed from the true and false positive and negative cases using Reitsma's bivariate random-effects and bivariate latent class models. Test performance reported in area under the curve (AUC) of the three nucleic acid tests was further compared by pooling studies with similar experimental setups (eg, tests that used RNA extracted pharyngeal swabs but with either the open reading frame 1ab or the N primer). Heterogeneity was assessed and reported in I 2 and τ2. FINDINGS Our search identified 1277 studies of which we included 66 studies (11 dPCR, 32 qPCR, and 23 LAMP) with 15 017 clinical samples in total in our systematic review and 52 studies in our meta-analysis. dPCR had the highest pooled diagnostic sensitivity (94·1%, 95% CI 88·9-96·6, by Reitsma's model and 95·8%, 54·9-100·0, by latent class model), followed by qPCR (92·7%, 88·3-95·6, and 93·4%, 60·9-99·9) and LAMP (83·3%, 76·9-88·2, and 86·2%, 20·7-99·9), using EUA-approved PCR kits as the reference standard. LAMP was the most specific with a pooled estimate of 96·3% (93·8-97·8) by Reitsma's model and 94·3% (49·1-100·0) by latent class model, followed by qPCR (92·9%, 87·2-96·2, and 93·1%, 47·1-100·0) and dPCR (78·5%, 57·4-90·8, and 73·8%, 0·9-100·0). The overall heterogeneity was I 2 0·5% (τ2 2·79) for dPCR studies, 0% (4·60) for qPCR studies, and 0% (3·96) for LAMP studies. AUCs of the three nucleic acid tests were the highest and differed the least between tests (ie, AUC>0·98 for all tests) when performed with RNA extracted pharyngeal swabs using SARS-CoV-2 open reading frame 1ab primer. INTERPRETATION All three nucleic acid tests consistently perform better with pharyngeal swabs using SARS-CoV-2 open reading frame 1ab primer with RNA extraction. dPCR was shown to be the most sensitive, followed by qPCR and LAMP. However, their accuracy does not differ significantly. Instead, accuracy depends on specific experimental conditions, implying that more efforts should be directed to optimising the experimental setups for the nucleic acid tests. Hence, our results could be a reference for optimising and establishing a standard nucleic acid test protocol that is applicable in laboratories worldwide. FUNDING University Grants Committee and The Chinese University of Hong Kong.
Collapse
Affiliation(s)
- Wing Ying Au
- Department of Chemical Pathology, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong Special Administrative Region, China
- Li Ka Shing Institute of Health Sciences, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong Special Administrative Region, China
- Department of Chemistry, Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong Special Administrative Region, China
| | - Peter Pak Hang Cheung
- Department of Chemical Pathology, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong Special Administrative Region, China
- Li Ka Shing Institute of Health Sciences, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong Special Administrative Region, China
- Department of Chemistry, Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong Special Administrative Region, China
| |
Collapse
|
36
|
Davidson JL, Wang J, Maruthamuthu MK, Dextre A, Pascual-Garrigos A, Mohan S, Putikam SVS, Osman FOI, McChesney D, Seville J, Verma MS. A paper-based colorimetric molecular test for SARS-CoV-2 in saliva. Biosens Bioelectron X 2021; 9:100076. [PMID: 34423284 PMCID: PMC8364207 DOI: 10.1016/j.biosx.2021.100076] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 08/09/2021] [Accepted: 08/10/2021] [Indexed: 04/16/2023]
Abstract
Herein, we describe the development of a paper-based device to detect nucleic acids of pathogens of interest in complex samples using loop-mediated isothermal amplification (LAMP) by producing a colorimetric response visible to the human eye. To demonstrate the utility of this device in emerging public health emergencies, we developed and optimized our device to detect SARS-CoV-2 in human saliva without preprocessing. The resulting device was capable of detecting the virus within 60 min and had an analytical sensitivity of 97% and a specificity of 100% with a limit of detection of 200 genomic copies/μL of patient saliva using image analysis. The device consists of a configurable number of reaction zones constructed of Grade 222 chromatography paper separated by 20 mil polystyrene spacers attached to a Melinex® backing via an ARclean® double-sided adhesive. The resulting device is easily configurable to detect multiple targets and has the potential to detect a variety of pathogens simply by changing the LAMP primer sets.
Collapse
Affiliation(s)
- Josiah Levi Davidson
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Jiangshan Wang
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Murali Kannan Maruthamuthu
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Andres Dextre
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Ana Pascual-Garrigos
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Suraj Mohan
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Sai Venkata Sravan Putikam
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | - Fujr Osman Ibrahim Osman
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
| | | | | | - Mohit S Verma
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN, 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN, 47907, USA
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, 47907, USA
| |
Collapse
|
37
|
Ghosh P, Chowdhury R, Hossain ME, Hossain F, Miah M, Rashid MU, Baker J, Rahman MZ, Rahman M, Ma X, Duthie MS, Wahed AAE, Mondal D. Evaluation of recombinase-based isothermal amplification assays for point-of-need detection of SARS-CoV-2 in resource-limited settings. Int J Infect Dis 2021; 114:105-111. [PMID: 34758392 PMCID: PMC8572376 DOI: 10.1016/j.ijid.2021.11.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Revised: 10/31/2021] [Accepted: 11/02/2021] [Indexed: 12/17/2022] Open
Abstract
Objectives The democratization of diagnostics is one of the key challenges towards containing the transmission of coronavirus disease 2019 (COVID-19) around the globe. The operational complexities of existing PCR-based methods, including sample transfer to advanced central laboratories with expensive equipment, limit their use in resource-limited settings. However, with the advent of isothermal technologies, the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is possible at decentralized facilities. Methods In this study, two recombinase-based isothermal techniques, reverse transcription recombinase polymerase amplification (RT-RPA) and reverse transcription recombinase-aided amplification (RT-RAA), were evaluated for the detection of SARS-CoV-2 in clinical samples. A total of 76 real-time reverse transcription PCR (real-time RT-PCR) confirmed COVID-19 cases and 100 negative controls were evaluated to determine the diagnostic performance of the isothermal methods. Results This investigation revealed equally promising diagnostic accuracy of the two methods, with a sensitivity of 76.32% (95% confidence interval 65.18–85.32%) when the target genes were RdRP and ORF1ab for RT-RPA and RT-RAA, respectively; the combination of N and RdRP in RT-RPA augmented the accuracy of the assay at a sensitivity of 85.53% (95% confidence interval 75.58–92.55%). Furthermore, high specificity was observed for each of the methods, ranging from 94.00% to 98.00% (95% confidence interval 87.40–9.76%). Conclusions Considering the diagnostic accuracies, both RT-RPA and RT-RAA appear to be suitable assays for point-of-need deployment for the detection of the pathogen, understanding its epidemiology, case management, and curbing transmission.
Collapse
Affiliation(s)
- Prakash Ghosh
- Emerging Infections and Parasitology Laboratory, NCSD, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, 1212, Bangladesh
| | - Rajashree Chowdhury
- Emerging Infections and Parasitology Laboratory, NCSD, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, 1212, Bangladesh
| | - Mohammad Enayet Hossain
- Virology Laboratory, IDD, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, 1212, Bangladesh
| | - Faria Hossain
- Emerging Infections and Parasitology Laboratory, NCSD, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, 1212, Bangladesh
| | - Mojnu Miah
- Virology Laboratory, IDD, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, 1212, Bangladesh
| | - Md Utba Rashid
- Emerging Infections and Parasitology Laboratory, NCSD, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, 1212, Bangladesh
| | - James Baker
- Laboratory Science and Services Division, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, 1212, Bangladesh
| | - Mohammed Ziaur Rahman
- Virology Laboratory, IDD, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, 1212, Bangladesh
| | - Mustafizur Rahman
- Virology Laboratory, IDD, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, 1212, Bangladesh
| | - Xuejun Ma
- Chinese Center for Disease Control and Prevention, National Institute for Viral Disease Control and Prevention, Beijing, 102206, China
| | - Malcolm S Duthie
- HDT Bio Corp, Suite 280, 1616 Eastlake Ave E, Seattle, WA, 98102, USA
| | - Ahmed Abd El Wahed
- Institute of Animal Hygiene and Veterinary Public Health, University of Leipzig, An den Tierkliniken 43, D-04103, Leipzig, Germany.
| | - Dinesh Mondal
- Emerging Infections and Parasitology Laboratory, NCSD, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, 1212, Bangladesh; Laboratory Science and Services Division, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, 1212, Bangladesh.
| |
Collapse
|
38
|
Saki EF, Setiawan SA, Wicaksono DHB. Portable Tools for COVID-19 Point-of-Care Detection: A Review. IEEE Sens J 2021; 21:23737-23750. [PMID: 35582343 PMCID: PMC8864949 DOI: 10.1109/jsen.2021.3110857] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 08/22/2021] [Accepted: 08/26/2021] [Indexed: 06/12/2023]
Abstract
Recently, several methods for SARS-CoV-2 detection have been developed to obtain rapid, portable, cheap, and easy-to-use diagnostic tools. This review paper summarizes and discusses studies on the development of point-of-care devices for SARS-CoV-2 diagnosis with comparisons between them from several aspects. Various detection methods of the recently developed portable COVID-19 biosensor will be presented in this review. The discussion is divided into four major classifications based on the target biomarkers of SARS-CoV-2, such as antibodies, nucleic acids, antigens, and metabolic products. An overview of the potential development for future study is also provided. Moreover, basic knowledge of biosensors is also explained for tutoring the implementation of theory into the research of COVID-19 biosensors. This review paper is aimed to provide a tutorial by collecting the information on the development of a point-of-care device for SARS-CoV-2 detection to provide information for further research and propose the new COVID-19 portable diagnostic tool.
Collapse
Affiliation(s)
- Elga F. Saki
- Department of Biomedical EngineeringFaculty of Life Sciences and TechnologySwiss German University (SGU)Tangerang15143Indonesia
| | | | - Dedy H. B. Wicaksono
- Department of Biomedical EngineeringFaculty of Life Sciences and TechnologySwiss German University (SGU)Tangerang15143Indonesia
| |
Collapse
|
39
|
LeGoff J, Kernéis S, Elie C, Mercier-Delarue S, Gastli N, Choupeaux L, Fourgeaud J, Alby ML, Quentin P, Pavie J, Brazille P, Néré ML, Minier M, Gabassi A, Leroy C, Parfait B, Tréluyer JM, Delaugerre C. Evaluation of a saliva molecular point of care for the detection of SARS-CoV-2 in ambulatory care. Sci Rep 2021; 11:21126. [PMID: 34702867 PMCID: PMC8548486 DOI: 10.1038/s41598-021-00560-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 10/11/2021] [Indexed: 11/09/2022] Open
Abstract
Rapid identification of SARS-CoV-2-infected individuals is a cornerstone for the control of virus spread. The sensitivity of SARS-CoV-2 RNA detection by RT-PCR is similar in saliva and nasopharyngeal swabs. Rapid molecular point-of-care tests in saliva could facilitate, broaden and speed up the diagnosis. We conducted a prospective study in two community COVID-19 screening centers to evaluate the performances of a CE-marked RT-LAMP assay (EasyCoV) designed for the detection of SARS-CoV2 RNA from fresh saliva samples, compared to nasopharyngeal RT-PCR, to saliva RT-PCR and to nasopharyngeal antigen testing. Overall, 117 of the 1718 participants (7%) tested positive with nasopharyngeal RT-PCR. Compared to nasopharyngeal RT-PCR, the sensitivity and specificity of the RT-LAMP assay in saliva were 34% and 97%, respectively. The Ct values of nasopharyngeal RT-PCR were significantly lower in the 40 true positive subjects with saliva RT-LAMP (Ct 25.9) than in the 48 false negative subjects with saliva RT-LAMP (Ct 28.4) (p = 0.028). Considering six alternate criteria for reference tests, including saliva RT-PCR and nasopharyngeal antigen, the sensitivity of saliva RT-LAMP ranged between 27 and 44%. The detection of SARS-CoV-2 in crude saliva samples with an RT-LAMP assay had a lower sensitivity than nasopharyngeal RT-PCR, saliva RT-PCR and nasopharyngeal antigen testing. Registration number: NCT04578509.
Collapse
Affiliation(s)
- Jérôme LeGoff
- Virologie, AP-HP, Hôpital Saint Louis, 1 Avenue Claude Vellefaux, 75010, Paris, France. .,INSERM, Equipe INSIGHT, U976, 75010, Université de Paris, Paris, France.
| | - Solen Kernéis
- INSERM, IAME, Université de Paris, 75018, Paris, France.,Equipe de Prévention du Risque Infectieux, AP-HP, Hôpital Bichat, 75018, Paris, France.,Institut Pasteur, Epidemiology and Modelling of Antibiotic Evasion, 75015, Paris, France
| | - Caroline Elie
- Clinical Research Unit / Clinical Investigation Center, APHP, Necker-Enfants Malades Hospital, 75015, Paris, France.,EA 7323 Pharmacologie et Thérapeutique de l'enfant et de la Femme Enceinte, Université de Paris, 75015, Paris, France
| | | | - Nabil Gastli
- Plateforme Covid IDF, AP-HP Centre, 75014, Paris, France
| | - Laure Choupeaux
- Clinical Research Unit / Clinical Investigation Center, APHP, Necker-Enfants Malades Hospital, 75015, Paris, France
| | - Jacques Fourgeaud
- Virologie, AP-HP, Hôpital Necker-Enfants Malades, 75015, Paris, France
| | - Marie-Laure Alby
- Centre de Dépistage COVISAN 13 14 15, Communauté Professionnelle de Territoire de Santé, 75014, Paris, France
| | - Pierre Quentin
- Centre de Dépistage COVISAN 13 14 15, Communauté Professionnelle de Territoire de Santé, 75014, Paris, France
| | - Juliette Pavie
- Immuno-Infectiologie, AP-HP, Hôtel Dieu, 75004, Paris, France.,Centre de Dépistage COVISAN, AP-HP, Hôtel-Dieu, 75004, Paris, France
| | - Patricia Brazille
- Immuno-Infectiologie, AP-HP, Hôtel Dieu, 75004, Paris, France.,Centre de Dépistage COVISAN, AP-HP, Hôtel-Dieu, 75004, Paris, France
| | - Marie Laure Néré
- Virologie, AP-HP, Hôpital Saint Louis, 1 Avenue Claude Vellefaux, 75010, Paris, France
| | - Marine Minier
- Virologie, AP-HP, Hôpital Saint Louis, 1 Avenue Claude Vellefaux, 75010, Paris, France
| | - Audrey Gabassi
- Virologie, AP-HP, Hôpital Saint Louis, 1 Avenue Claude Vellefaux, 75010, Paris, France
| | - Chrystel Leroy
- Plateforme Covid IDF, AP-HP Centre, 75014, Paris, France.,Plateforme SeqOIA, AP-HP, 75014, Paris, France
| | - Béatrice Parfait
- Centre de Ressources Biologiques, Hôpital Cochin, 75014, Paris, France
| | - Jean-Marc Tréluyer
- Clinical Research Unit / Clinical Investigation Center, APHP, Necker-Enfants Malades Hospital, 75015, Paris, France.,EA 7323 Pharmacologie et Thérapeutique de l'enfant et de la Femme Enceinte, Université de Paris, 75015, Paris, France
| | - Constance Delaugerre
- Virologie, AP-HP, Hôpital Saint Louis, 1 Avenue Claude Vellefaux, 75010, Paris, France.,INSERM, U944, 75010, Université de Paris, Paris, France
| |
Collapse
|
40
|
Kaur A, Chopra M, Bhushan M, Gupta S, Kumari P H, Sivagurunathan N, Shukla N, Rajagopal S, Bhalothia P, Sharma P, Naravula J, Suravajhala R, Gupta A, Abbasi BA, Goswami P, Singh H, Narang R, Polavarapu R, Medicherla KM, Valadi J, Kumar S A, Chaubey G, Singh KK, Bandapalli OR, Kavi Kishor PB, Suravajhala P. The Omic Insights on Unfolding Saga of COVID-19. Front Immunol 2021; 12:724914. [PMID: 34745097 PMCID: PMC8564481 DOI: 10.3389/fimmu.2021.724914] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Accepted: 09/27/2021] [Indexed: 12/15/2022] Open
Abstract
The year 2019 has seen an emergence of the novel coronavirus named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causing coronavirus disease of 2019 (COVID-19). Since the onset of the pandemic, biological and interdisciplinary research is being carried out across the world at a rapid pace to beat the pandemic. There is an increased need to comprehensively understand various aspects of the virus from detection to treatment options including drugs and vaccines for effective global management of the disease. In this review, we summarize the salient findings pertaining to SARS-CoV-2 biology, including symptoms, hosts, epidemiology, SARS-CoV-2 genome, and its emerging variants, viral diagnostics, host-pathogen interactions, alternative antiviral strategies and application of machine learning heuristics and artificial intelligence for effective management of COVID-19 and future pandemics.
Collapse
Affiliation(s)
- Arvinpreet Kaur
- Department of Bioinformatics, Hans Raj Mahila Maha Vidyalaya, Punjab, India
- Bioclues.org, Hyderabad, India
| | - Mehak Chopra
- Centre for Bioinformatics, School of Life Sciences, Pondicherry University, Puducherry, India
| | - Mahak Bhushan
- Department of Biological Sciences, Indian Institute of Science Education and Research, Kolkata, India
| | - Sonal Gupta
- Bioclues.org, Hyderabad, India
- Department of Biotechnology and Bioinformatics, Birla Institute of Scientific Research, Jaipur, India
| | | | - Narmadhaa Sivagurunathan
- Department of Biotechnology and Bioinformatics, Birla Institute of Scientific Research, Jaipur, India
| | - Nidhi Shukla
- Bioclues.org, Hyderabad, India
- Department of Biotechnology and Bioinformatics, Birla Institute of Scientific Research, Jaipur, India
| | - Shalini Rajagopal
- Vignan’s Foundation for Science, Technology & Research (Deemed to be University), Guntur, India
| | - Purva Bhalothia
- Department of Biotechnology and Bioinformatics, Birla Institute of Scientific Research, Jaipur, India
| | - Purnima Sharma
- Department of Bioinformatics, Hans Raj Mahila Maha Vidyalaya, Punjab, India
| | - Jalaja Naravula
- Vignan’s Foundation for Science, Technology & Research (Deemed to be University), Guntur, India
| | - Renuka Suravajhala
- Bioclues.org, Hyderabad, India
- Department of Chemistry, School of Basic Sciences, Manipal University Jaipur, Jaipur, India
| | - Ayam Gupta
- Vignan’s Foundation for Science, Technology & Research (Deemed to be University), Guntur, India
| | - Bilal Ahmed Abbasi
- Functional Genomics Unit, Council of Scientific and Industrial Research- Institute of Genomics & Integrative Biology (CSIR-IGIB), Delhi, India
| | - Prittam Goswami
- Department of Biotechnology, Haldia Institute of Technology, West Bengal, India
| | - Harpreet Singh
- Department of Bioinformatics, Hans Raj Mahila Maha Vidyalaya, Punjab, India
- Bioclues.org, Hyderabad, India
| | - Rahul Narang
- Department of Microbiology, All India Institute of Medical Sciences, Bibinagar, Hyderabad, India
| | | | - Krishna Mohan Medicherla
- Department of Biotechnology and Bioinformatics, Birla Institute of Scientific Research, Jaipur, India
| | - Jayaraman Valadi
- Bioclues.org, Hyderabad, India
- Department of Computer Science, Flame University, Pune, India
| | - Anil Kumar S
- Vignan’s Foundation for Science, Technology & Research (Deemed to be University), Guntur, India
| | - Gyaneshwer Chaubey
- Cytogenetics Laboratory, Department of Zoology, Benaras Hindu University, Varanasi, India
| | - Keshav K. Singh
- Department of Genetics, University of Alabama, Birmingham, AL, United States
| | - Obul Reddy Bandapalli
- Bioclues.org, Hyderabad, India
- German Cancer Research Centre (DKFZ), Heidelberg, Germany
- Department of Applied Biology, Council of Scientific and Industrial Research-Indian Institute of Chemical Technology (CSIR-IICT), Hyderabad, India
| | - Polavarapu Bilhan Kavi Kishor
- Bioclues.org, Hyderabad, India
- Vignan’s Foundation for Science, Technology & Research (Deemed to be University), Guntur, India
| | - Prashanth Suravajhala
- Bioclues.org, Hyderabad, India
- Department of Biotechnology and Bioinformatics, Birla Institute of Scientific Research, Jaipur, India
- Amrita School of Biotechnology, Amrita Vishwa Vidyapeetham, Kerala, India
| |
Collapse
|
41
|
Mohammadniaei M, Zhang M, Ashley J, Christensen UB, Friis-Hansen LJ, Gregersen R, Lisby JG, Benfield TL, Nielsen FE, Henning Rasmussen J, Pedersen EB, Olinger ACR, Kolding LT, Naseri M, Zheng T, Wang W, Gorodkin J, Sun Y. A non-enzymatic, isothermal strand displacement and amplification assay for rapid detection of SARS-CoV-2 RNA. Nat Commun 2021; 12:5089. [PMID: 34429424 DOI: 10.1038/s41467-021-25387-9] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 08/09/2021] [Indexed: 12/24/2022] Open
Abstract
The current nucleic acid signal amplification methods for SARS-CoV-2 RNA detection heavily rely on the functions of biological enzymes which imposes stringent transportation and storage conditions, high cost and global supply shortages. Here, a non-enzymatic whole genome detection method based on a simple isothermal signal amplification approach is developed for rapid detection of SARS-CoV-2 RNA and potentially any types of nucleic acids regardless of their size. The assay, termed non-enzymatic isothermal strand displacement and amplification (NISDA), is able to quantify 10 RNA copies.µL−1. In 164 clinical oropharyngeal RNA samples, NISDA assay is 100 % specific, and it is 96.77% and 100% sensitive when setting up in the laboratory and hospital, respectively. The NISDA assay does not require RNA reverse-transcription step and is fast (<30 min), affordable, highly robust at room temperature (>1 month), isothermal (42 °C) and user-friendly, making it an excellent assay for broad-based testing. The reliance on enzymes in SARS-CoV-2 RNA detection imposes limits on transport and storage conditions. Here the authors use non-enzymatic isothermal amplification to detect RNA with no need for reverse transcription.
Collapse
|
42
|
Alafeef M, Moitra P, Dighe K, Pan D. Hyperspectral Mapping for the Detection of SARS-CoV-2 Using Nanomolecular Probes with Yoctomole Sensitivity. ACS Nano 2021; 15:13742-13758. [PMID: 34279093 PMCID: PMC8315249 DOI: 10.1021/acsnano.1c05226] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 07/14/2021] [Indexed: 05/02/2023]
Abstract
Efficient monitoring of SARS-CoV-2 outbreak requires the use of a sensitive and rapid diagnostic test. Although SARS-CoV-2 RNA can be detected by RT-qPCR, the molecular-level quantification of the viral load is still challenging, time-consuming, and labor-intensive. Here, we report an ultrasensitive hyperspectral sensor (HyperSENSE) based on hafnium nanoparticles (HfNPs) for specific detection of COVID-19 causative virus, SARS-CoV-2. Density functional theoretical calculations reveal that HfNPs exhibit higher changes in their absorption wavelength and light scattering when bound to their target SARS-CoV-2 RNA sequence relative to the gold nanoparticles. The assay has a turnaround time of a few seconds and has a limit of detection in the yoctomolar range, which is 1 000 000-fold times higher than the currently available COVID-19 tests. We demonstrated in ∼100 COVID-19 clinical samples that the assay is highly sensitive and has a specificity of 100%. We also show that HyperSENSE can rapidly detect other viruses such as influenza A H1N1. The outstanding sensitivity indicates the potential of the current biosensor in detecting the prevailing presymptomatic and asymptomatic COVID-19 cases. Thus, integrating hyperspectral imaging with nanomaterials establishes a diagnostic platform for ultrasensitive detection of COVID-19 that can potentially be applied to any emerging infectious pathogen.
Collapse
Affiliation(s)
- Maha Alafeef
- Bioengineering Department, The University
of Illinois at Urbana−Champaign, Urbana, Illinois 61801,
United States
- Departments of Diagnostic Radiology and Nuclear
Medicine and Pediatrics, Center for Blood Oxygen Transport and Hemostasis,
University of Maryland Baltimore School of Medicine, Health
Sciences Research Facility III, 670 W. Baltimore Street, Baltimore, Maryland 21201,
United States
- Biomedical Engineering Department, Jordan
University of Science and Technology, Irbid 22110,
Jordan
- Department of Chemical, Biochemical and Environmental
Engineering, University of Maryland Baltimore County,
Interdisciplinary Health Sciences Facility, 1000 Hilltop Circle, Baltimore, Maryland
21250, United States
| | - Parikshit Moitra
- Departments of Diagnostic Radiology and Nuclear
Medicine and Pediatrics, Center for Blood Oxygen Transport and Hemostasis,
University of Maryland Baltimore School of Medicine, Health
Sciences Research Facility III, 670 W. Baltimore Street, Baltimore, Maryland 21201,
United States
| | - Ketan Dighe
- Departments of Diagnostic Radiology and Nuclear
Medicine and Pediatrics, Center for Blood Oxygen Transport and Hemostasis,
University of Maryland Baltimore School of Medicine, Health
Sciences Research Facility III, 670 W. Baltimore Street, Baltimore, Maryland 21201,
United States
- Department of Chemical, Biochemical and Environmental
Engineering, University of Maryland Baltimore County,
Interdisciplinary Health Sciences Facility, 1000 Hilltop Circle, Baltimore, Maryland
21250, United States
| | - Dipanjan Pan
- Bioengineering Department, The University
of Illinois at Urbana−Champaign, Urbana, Illinois 61801,
United States
- Departments of Diagnostic Radiology and Nuclear
Medicine and Pediatrics, Center for Blood Oxygen Transport and Hemostasis,
University of Maryland Baltimore School of Medicine, Health
Sciences Research Facility III, 670 W. Baltimore Street, Baltimore, Maryland 21201,
United States
- Department of Chemical, Biochemical and Environmental
Engineering, University of Maryland Baltimore County,
Interdisciplinary Health Sciences Facility, 1000 Hilltop Circle, Baltimore, Maryland
21250, United States
| |
Collapse
|
43
|
Biyani R, Sharma K, Kojima K, Biyani M, Sharma V, Kumawat T, Juma KM, Yanagihara I, Fujiwara S, Kodama E, Takamura Y, Takagi M, Yasukawa K, Biyani M. Development of robust isothermal RNA amplification assay for lab-free testing of RNA viruses. Sci Rep 2021; 11:15997. [PMID: 34362977 PMCID: PMC8346491 DOI: 10.1038/s41598-021-95411-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Accepted: 07/26/2021] [Indexed: 11/30/2022] Open
Abstract
Simple tests of infectiousness that return results in minutes and directly from samples even with low viral loads could be a potential game-changer in the fight against COVID-19. Here, we describe an improved isothermal nucleic acid amplification assay, termed the RICCA (RNA Isothermal Co-assisted and Coupled Amplification) reaction, that consists of a simple one-pot format of ‘sample-in and result-out’ with a primary focus on the detection of low copy numbers of RNA virus directly from saliva without the need for laboratory processing. We demonstrate our assay by detecting 16S rRNA directly from E. coli cells with a sensitivity as low as 8 CFU/μL and RNA fragments from a synthetic template of SARS-CoV-2 with a sensitivity as low as 1740 copies/μL. We further demonstrate the applicability of our assay for real-time testing at the point of care by designing a closed format for paper-based lateral flow assay and detecting heat-inactivated SARS-COV-2 virus in human saliva at concentrations ranging from 28,000 to 2.8 copies/μL with a total assay time of 15–30 min.
Collapse
Affiliation(s)
- Radhika Biyani
- Department of Bioscience and Biotechnology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi City, Ishikawa, 923-1292, Japan
| | - Kirti Sharma
- BioSeeds Corporation, JAIST Venture Business Laboratory, Ishikawa Create Labo, Asahidai 2-13, Nomi City, Ishikawa, 923-1211, Japan
| | - Kenji Kojima
- Division of Food Science and Biotechnology, Graduate School of Agriculture, Kyoto University, Sakyo-ku, Kyoto, 606-8502, Japan
| | - Madhu Biyani
- BioSeeds Corporation, JAIST Venture Business Laboratory, Ishikawa Create Labo, Asahidai 2-13, Nomi City, Ishikawa, 923-1211, Japan.,Biyani BioSolutions Pvt. Ltd., Biyani Group of Colleges Venture Business Laboratory, R-4, Sector 3, Vidhyadhar Nagar, Jaipur, 302039, India
| | - Vishnu Sharma
- Biyani BioSolutions Pvt. Ltd., Biyani Group of Colleges Venture Business Laboratory, R-4, Sector 3, Vidhyadhar Nagar, Jaipur, 302039, India
| | - Tarun Kumawat
- Biyani BioSolutions Pvt. Ltd., Biyani Group of Colleges Venture Business Laboratory, R-4, Sector 3, Vidhyadhar Nagar, Jaipur, 302039, India
| | - Kevin Maafu Juma
- Division of Food Science and Biotechnology, Graduate School of Agriculture, Kyoto University, Sakyo-ku, Kyoto, 606-8502, Japan
| | - Itaru Yanagihara
- Department of Developmental Medicine, Research Institute, Osaka Women's and Children's Hospital, 840 Murodocho, Izumi, Osaka, 594-1101, Japan
| | - Shinsuke Fujiwara
- Department of Biosciences, School of Biological and Environmental Sciences, Kwansei-Gakuin University, 2-1 Gakuen, Sanda, Hyogo, 669-1337, Japan
| | - Eiichi Kodama
- Division of Infectious Diseases, International Research Institute of Disaster Science, Tohoku University, 2-1 Seiryocho Aoba-ku, Sendai, Miyagi, 980-8575, Japan
| | - Yuzuru Takamura
- Department of Bioscience and Biotechnology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi City, Ishikawa, 923-1292, Japan
| | - Masahiro Takagi
- Department of Bioscience and Biotechnology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi City, Ishikawa, 923-1292, Japan
| | - Kiyoshi Yasukawa
- Division of Food Science and Biotechnology, Graduate School of Agriculture, Kyoto University, Sakyo-ku, Kyoto, 606-8502, Japan
| | - Manish Biyani
- Department of Bioscience and Biotechnology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi City, Ishikawa, 923-1292, Japan. .,BioSeeds Corporation, JAIST Venture Business Laboratory, Ishikawa Create Labo, Asahidai 2-13, Nomi City, Ishikawa, 923-1211, Japan. .,Biyani BioSolutions Pvt. Ltd., Biyani Group of Colleges Venture Business Laboratory, R-4, Sector 3, Vidhyadhar Nagar, Jaipur, 302039, India.
| |
Collapse
|
44
|
Abstract
CoVID-19 is a multi-symptomatic disease which has made a global impact due to its ability to spread rapidly, and its relatively high mortality rate. Beyond the heroic efforts to develop vaccines, which we do not discuss herein, the response of scientists and clinicians to this complex problem has reflected the need to detect CoVID-19 rapidly, to diagnose patients likely to show adverse symptoms, and to treat severe and critical CoVID-19. Here we aim to encapsulate these varied and sometimes conflicting approaches and the resulting data in terms of chemistry and biology. In the process we highlight emerging concepts, and potential future applications that may arise out of this immense effort.
Collapse
Affiliation(s)
| | - Yimon Aye
- Swiss Federal Institute of Technology in Lausanne (EPFL)1015LausanneSwitzerland
| |
Collapse
|
45
|
Abstract
The introduction of nucleic acid amplification techniques has revolutionized the field of medical diagnostics in the last decade. The advent of PCR catalyzed the increasing application of DNA, not just for molecular cloning but also for molecular based diagnostics. Since the introduction of PCR, a deeper understanding of molecular mechanisms and enzymes involved in DNA/RNA replication has spurred the development of novel methods devoid of temperature cycling. Isothermal amplification methods have since been introduced utilizing different mechanisms, enzymes, and conditions. The ease with which isothermal amplification methods have allowed nucleic acid amplification to be carried out has had a profound impact on the way molecular diagnostics are being designed after the turn of the millennium. With all the advantages isothermal amplification brings, the issues or complications surrounding each method are heterogeneous making it difficult to identify the best approach for an end-user. This review pays special attention to the various isothermal amplification methods by classifying them based on the mechanistic characteristics which include reaction formats, amplification information, promoter, strand break, and refolding mechanisms. We would also compare the efficiencies and usefulness of each method while highlighting the potential applications and detection methods involved. This review will serve as an overall outlook on the journey and development of isothermal amplification methods as a whole.
Collapse
Affiliation(s)
- Jörn Glökler
- Department of Molecular Biotechnology and Functional Genomics, Technical University of Applied Sciences Wildau, Wildau, Germany
| | - Theam Soon Lim
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Penang, Malaysia
| | - Jeunice Ida
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, Penang, Malaysia
| | - Marcus Frohme
- Department of Molecular Biotechnology and Functional Genomics, Technical University of Applied Sciences Wildau, Wildau, Germany
| |
Collapse
|
46
|
Abstract
Nucleic acids, including deoxyribonucleic acid (DNA) and ribonucleic acid (RNA), are natural biopolymers composed of nucleotides that store, transmit, and express genetic information. Overexpressed or underexpressed as well as mutated nucleic acids have been implicated in many diseases. Therefore, nucleic acid tests (NATs) are extremely important. Inspired by intracellular DNA replication and RNA transcription, in vitro NATs have been extensively developed to improve the detection specificity, sensitivity, and simplicity. The principles of NATs can be in general classified into three categories: nucleic acid hybridization, thermal-cycle or isothermal amplification, and signal amplification. Driven by pressing needs in clinical diagnosis and prevention of infectious diseases, NATs have evolved to be a rapidly advancing field. During the past ten years, an explosive increase of research interest in both basic research and clinical translation has been witnessed. In this review, we aim to provide comprehensive coverage of the progress to analyze nucleic acids, use nucleic acids as recognition probes, construct detection devices based on nucleic acids, and utilize nucleic acids in clinical diagnosis and other important fields. We also discuss the new frontiers in the field and the challenges to be addressed.
Collapse
Affiliation(s)
- Min Li
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Fangfei Yin
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Lu Song
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.,Division of Physical Biology, CAS Key Laboratory of Interfacial Physics and Technology, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
| | - Xiuhai Mao
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Fan Li
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Chunhai Fan
- School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules and National Center for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Xiaolei Zuo
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.,School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules and National Center for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Qiang Xia
- Institute of Molecular Medicine, Department of Liver Surgery, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| |
Collapse
|
47
|
Abstract
COVID-19 pandemic has become a global public health priority. The rapid increase in infection numbers, along with a significant number of deaths, has made the virus a serious threat to human health. Rapid, reliable, and simple diagnostic methods are critical to controlling the disease. While Reverse Transcriptase Polymerase Chain Reaction (RT-PCR) is the current diagnostic gold standard, Reverse Transcriptase Loop-Mediated Isothermal Amplification (RT-LAMP) appears to be a compelling alternative diagnostic test due to its greater simplicity, shorter time to obtain a result, and lower cost. This study examined RT-LAMP application for rapid identification of SARS-CoV-2 infection compared to the RT-PCR assay. A systematic review and meta-analysis was conducted over six scientific databases in accordance with PRISMA guidelines. Original studies published in English conducted on human clinical samples were included. Articles evaluating the sensitivity and specificity of RT-LAMP relative to RT-PCR were considered eligible. Quality assessment of bias and applicability was examined based on QUADAS-2. A total of 351 studies were found based on the keywords and search queries. Fourteen eligible case-control studies fit the mentioned criteria. Quality assessment using QUADAS-2 indicated alow risk of bias for all included studies. All case studies, containing 2,112 samples, had acumulative sensitivity of 95.5% (CI 97.5% = 90.8-97.9%) and cumulative specificity of 99.5% (CI 97.5% = 97.7-99.9%). The RT-LAMP assay could be areliable alternative COVID-19 diagnostic method due to its reduced cost and processing time compared to RT-PCR. RT-LAMP could potentially be utilized during critical high-throughput and high-demand situations.
Collapse
Affiliation(s)
- Anita Dominique Subali
- Faculty of Medicine, Universitas Brawijaya, Malang, East Java, Indonesia
- Faculty of Medicine, Universitas Indonesia - Cipto Mangunkusumo Hospital, Jakarta, Indonesia
| | - Lowilius Wiyono
- Faculty of Medicine, Universitas Brawijaya, Malang, East Java, Indonesia
- Faculty of Medicine, Universitas Indonesia - Cipto Mangunkusumo Hospital, Jakarta, Indonesia
| |
Collapse
|
48
|
Peto J. Weekly population testing could stop this pandemic and prevent the next. R Soc Open Sci 2021; 8:210468. [PMID: 34295528 PMCID: PMC8278036 DOI: 10.1098/rsos.210468] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 07/01/2021] [Indexed: 06/13/2023]
Abstract
The rapid spread of the SARS-COV-2 delta variant in the UK despite high vaccination coverage will inevitably accelerate when social restrictions end unless testing and contact tracing become much more effective. To minimize further social and economic damage, the effect on R of introducing weekly population testing as social restrictions are relaxed should be evaluated. The large increase in testing capacity required can be achieved with self-taken saliva samples analysed by RT-LAMP in local testing facilities. The costs and effectiveness can be evaluated in whole-city demonstration studies. A local population register in each city or district is essential to issue weekly invitations, manage sample collection, monitor results and achieve rapid notification of households and other contacts when a test is positive. In the UK, weekly test invitations should be managed, like vaccination invitations, by the NHS, with social and financial support for quarantined households to make self-isolation acceptable. A framework for effective population testing that had been established and evaluated during this pandemic could be rapidly reinstated to suppress the next pandemic while vaccines for a new and perhaps more deadly virus are developed and rolled out.
Collapse
Affiliation(s)
- Julian Peto
- London School of Hygiene and Tropical Medicine, London, UK
| |
Collapse
|
49
|
Burnes LE, Clark ST, Sheldrake E, Faheem A, Poon BP, Christie-Holmes N, Finlay L, Kandel C, Phan M, Frankland C, Lau T, Gubbay JB, Corbeil A, Katz K, Kozak RA. One swab, two tests: Validation of dual SARS-CoV-2 testing on the Abbott ID NOW™. J Clin Virol 2021; 141:104896. [PMID: 34174710 PMCID: PMC8196482 DOI: 10.1016/j.jcv.2021.104896] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 05/31/2021] [Accepted: 06/03/2021] [Indexed: 11/25/2022]
Abstract
Background Point-of-care tests (POCT) are promising tools to detect SARS-CoV-2 in specific settings. Initial reports suggest the ID NOW™ COVID-19 assay (Abbott Diagnostics Inc, USA) is less sensitive than standard real-time reverse transcription polymerase chain reaction (rRT-PCR) assays. This has raised concern over false negatives in SARS-CoV-2 POCT. Objectives We compared the performance of the ID NOW™ COVID-19 assay to our in-house rRT-PCR assay to assess whether dry swabs used in ID NOW™ testing could be stored in transport media and be re-tested by rRT-PCR for redundancy and to provide material for further investigation. Methods Paired respiratory swabs collected from patients at three acute care hospitals were used. One swab in transport media (McMaster Molecular Media (MMM)) was tested for SARS-CoV-2 by a laboratory-developed two-target rRT-PCR assay. The second was stored dry in a sterile container and tested by the ID NOW™ COVID-19 assay. Following ID NOW™ testing, dry swabs were stored in MMM for up to 48 h and re-tested by rRT-PCR. Serially diluted SARS-CoV-2 particles were used to assess the impact of heat inactivation and storage time. Results Respiratory swabs (n = 343) from 179 individuals were included. Using rRT-PCR results as the comparator, the ID NOW™ COVID-19 assay had positive (PPA) and negative (NPA) percent agreements of 87.0% (95% CI:0.74–0.94) and 99.7% (95% CI:0.98–0.99). Re-tested swabs placed in MMM following ID NOW testing had PPA and NPA of 88.8% (95% CI:0.76–0.95) and 99.7% (95% CI:0.98–0.99), respectively. Conclusions Storing spent dry swabs in transport media for redundancy rRT-PCR testing is a potential approach to address possible false negatives with the ID NOW™ COVID-19 assay.
Collapse
Affiliation(s)
- Laura E Burnes
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, AB, Canada
| | - Shawn T Clark
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada
| | | | - Amna Faheem
- North York General Hospital, Toronto, ON, Canada
| | - Betty P Poon
- Combined Containment Level 3 Unit, University of Toronto,Toronto, ON, Canada
| | | | | | | | | | | | - Trevor Lau
- Shared Hospital Laboratory, Toronto, ON, Canada
| | - Jonathan B Gubbay
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada; Public Health Ontario Laboratory, Toronto, ON, Canada
| | - Antoine Corbeil
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada; Public Health Ontario Laboratory, Toronto, ON, Canada
| | - Kevin Katz
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada; Shared Hospital Laboratory, Toronto, ON, Canada; North York General Hospital, Toronto, ON, Canada; Sunnybrook Health Sciences Centre, Toronto, ON, Canada
| | - Robert A Kozak
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada; Shared Hospital Laboratory, Toronto, ON, Canada; Sunnybrook Health Sciences Centre, Toronto, ON, Canada.
| |
Collapse
|
50
|
Fellner MD, Bonaventura R, Basiletti J, Avaro M, Benedetti E, Campos A, Dattero ME, Russo M, Vladmirsky S, Molina V, Irazu L, Rodriguez MA, Pontoriero A, Cisterna DM, Baumeister EG. Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina. Genes (Basel) 2021; 12:659. [PMID: 33924826 DOI: 10.3390/genes12050659] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 04/14/2021] [Accepted: 04/23/2021] [Indexed: 12/19/2022] Open
Abstract
Our aim was to evaluate the analytical and clinical performance of the SARS-CoV-2 molecular detection kits used in Argentina. Nine real-time reverse-transcription polymerase chain reaction (RT-qPCR) and three reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assays were evaluated using the World Health Organization (WHO) recommended test as reference method. A secondary standard calibrated for the E, N and RdRp genes against the Pan American Health Organization—World Health Organization—International Standard was used to calculate the limit of detection (LoD). A panel of artificial clinical samples, 32 positive and 30 negative for SARS-CoV-2, were analyzed to estimate the kappa concordance (κ) and the diagnostic performance. Differences among the LoD values for the target genes amplified by each kit were >1 log copies/reaction. The κ for the RT-qPCR kits was greater than 0.9, whereas that for the RT-LAMP assays ranged from 0.75 to 0.93. The clinical performance of RT-qPCR kits showed 100% specificity and high sensitivity, although with variations according to the gene analyzed. The E and N genes provided greater clinical sensitivity, whereas the RdRp gene increased the clinical specificity. The RT-LAMP assays revealed a variable diagnostic performance. The information provided can be useful to choose the most appropriate diagnostic test and may contribute to the establishment of a consensus in the diagnosis of SARS-CoV-2 in Argentina and the region.
Collapse
|