1
|
Cockreham CB, Zhang X, Eakin JA, Dewa M, Li H, Li N, Sun J, Ha S, Ivory CF, Wang Y, Xu H, Wu D. Unveiling the Interfacial and Structural Heterogeneity of Ti 3C 2T x MXene Etched with CoF 2/HCl by Integrated in Situ Thermal Analysis. ACS Appl Mater Interfaces 2021; 13:52125-52133. [PMID: 34387989 DOI: 10.1021/acsami.1c10021] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
Ti3C2Tx MXene is a member of the recently discovered two-dimensional early transition metal carbide and nitride family of MXenes with potential applications in energy storage and heterogeneous catalysis at elevated temperatures. Here, we apply a suite of in situ techniques to probe Ti3C2Tx MXene's thermal evolutions, including in situ X-ray diffraction (XRD), in situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), and integrated thermogravimetry-differential scanning calorimetry-mass spectrometry (TG-DSC-MS). In light of this set of in situ investigations, we find heterogeneity in the layering of Ti3C2Tx MXene revealed only at higher temperatures. Our findings present behavior up to 600 °C, particularly interlayer water and -OH surface end-capping groups. In one group of layers, their interlayer spacing shrinks as water deintercalates, but the other group of layers unexpectedly shows no change in the interlayer spacing. This is strong evidence that intercalants act as guest pillaring agents in the latter layering group, which stabilize these layers at higher temperatures while keeping the interlayer space accessible.
Collapse
Affiliation(s)
- Cody B Cockreham
- Alexandra Navrotsky Institute for Experimental Thermodynamics, Washington State University, Pullman, Washington 99164, United States
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
- Earth and Environmental Sciences Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545, United States
| | - Xianghui Zhang
- Alexandra Navrotsky Institute for Experimental Thermodynamics, Washington State University, Pullman, Washington 99164, United States
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
| | - Jeffrey A Eakin
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
| | - Martinus Dewa
- School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Houqian Li
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
| | - Nan Li
- Center for Integrated Nanotechnologies, Los Alamos National Laboratory, Los Alamos, New Mexico 87545, United States
| | - Junming Sun
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
| | - Su Ha
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
| | - Cornelius F Ivory
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
| | - Yong Wang
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
- Institute for Integrated Catalysis, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Hongwu Xu
- Earth and Environmental Sciences Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545, United States
| | - Di Wu
- Alexandra Navrotsky Institute for Experimental Thermodynamics, Washington State University, Pullman, Washington 99164, United States
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington 99164, United States
- Department of Chemistry, Washington State University, Pullman, Washington 99164, United States
- Materials Science and Engineering, Washington State University, Pullman, Washington 99164, United States
| |
Collapse
|
2
|
Krzysko AJ, Nakouzi E, Zhang X, Graham TR, Rosso KM, Schenter GK, Ilavsky J, Kuzmenko I, Frith MG, Ivory CF, Clark SB, Weston JS, Weigandt KM, De Yoreo JJ, Chun J, Anovitz LM. Correlating inter-particle forces and particle shape to shear-induced aggregation/fragmentation and rheology for dilute anisotropic particle suspensions: A complementary study via capillary rheometry and in-situ small and ultra-small angle X-ray scattering. J Colloid Interface Sci 2020; 576:47-58. [DOI: 10.1016/j.jcis.2020.04.016] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Revised: 04/03/2020] [Accepted: 04/03/2020] [Indexed: 11/28/2022]
|
3
|
Medina AS, Tibbits G, Wall NA, Ivory CF, Clark SB, Beyenal H. Electrochemical precipitation of neptunium with a micro electrochemical quartz crystal microbalance. J Radioanal Nucl Chem 2020; 324:1021-1030. [PMID: 32601515 PMCID: PMC7323927 DOI: 10.1007/s10967-020-07138-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Indexed: 11/29/2022]
Abstract
Microliter volumes are used in electrochemical detection and preconcentration of radionuclides to reduce the dose received by researchers and equipment. Unfortunately, there is a lack of analysis of radionuclides with coupled electrochemical techniques and microliter volume reactors. The goals of this work are 1) to develop a miniaturized micro-electrochemical quartz crystal microbalance (µeQCM) reactor for use in small volume (50-200 µL) electrogravimetric experiments and 2) to use this reactor to characterize the preconcentration of neptunium on carbon electrodes via electroprecipitation. We successfully deposited neptunium in the new µeQCM reactor and verified its operation. We found that preconcentration of neptunium on carbon coated electrodes was possible by chronoamperometry at -1.6 VAg/AgCl. The mass shift of the resulting precipitate was indicative of the amount of neptunium on the electrode, although the correlation between the mass increase and activity of the preconcentrated material was not linear. Neptunium precipitate reduced electron transfer to the solution as evidenced by the increase in charge transfer resistance compared to bare electrodes.
Collapse
Affiliation(s)
- Adan Schafer Medina
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | - Gretchen Tibbits
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | - Nathalie A. Wall
- Department of Materials Science & Engineering, University of Florida, Gainesville, FL
| | - Cornelius F. Ivory
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | - Sue B. Clark
- Department of Chemistry, Washington State University, Pullman, WA, USA
- Pacific Northwest National Laboratory, Energy & Environment Directorate, Richland, WA, USA
| | - Haluk Beyenal
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| |
Collapse
|
4
|
Medina AS, Wall NA, Ivory CF, Clark SB, Beyenal H. Preconcentration mechanism of trivalent lanthanum on eQCM electrodes in the presence of α-hydroxy isobutyric acid. J Electroanal Chem (Lausanne) 2020; 857. [PMID: 34305495 DOI: 10.1016/j.jelechem.2019.113731] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Electroprecipitation can be used to preconcentrate lanthanum on carbon electrode surfaces. The use of complexing ligands is expected to improve the electroprecipitation of lanthanum by protecting La ions in solution from the alkaline region near the electrode surface. However, the electroprecipitation mechanism of La in the presence of a complexing ligand is not known. The goal of this work is to 1) determine the effect of the complexing ligand, α-hydroxy isobutyric acid (HIBA), on the electroprecipitation of La onto the gold electrodes, and 2) identify the changes in the mechanism of accumulation when preconcentrating in the presence of HIBA. We used an electrochemical quartz crystal microbalance (eQCM) and needle type pH microelectrodes to determine pH near the electrode surface in combination with cyclic voltammetry to understand the electroprecipitation mechanism. We used the bi-dentate ligand HIBA as a ligand and found that lanthanum electroprecipitation is hindered in the presence of HIBA. The presence of HIBA also delayed the onset of film formation during a cyclic voltammetric experiment by ~100 mV compared to experiments performed without HIBA. The shift in onset potential is attributed to the buffering action of HIBA (pKa = 3.7) since the shift is not present in subsequent scans. The precipitated film was characterized by scanning electron microscopy, X-ray photoelectron spectrometry, and Auger nanoprobe spectrometry. While we found that La(OH)3 was the predominant chemical state of the film on electrodes in the absence of HIBA, La2O3 was found for films created in the presence of HIBA. Our finding demonstrates that La(OH)3 can be electrodeposited at room temperature.
Collapse
Affiliation(s)
- Adan Schafer Medina
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | - Nathalie A Wall
- Department of Chemistry, Washington State University, Pullman, WA, USA
| | - Cornelius F Ivory
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | - Sue B Clark
- Department of Chemistry, Washington State University, Pullman, WA, USA
- Pacific Northwest National Laboratory, Energy & Environment Directorate, Richland, WA, USA
| | - Haluk Beyenal
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| |
Collapse
|
5
|
Guo S, Jacroux T, Ivory CF, Li L, Dong WJ. Immunobinding-induced alteration in the electrophoretic mobility of proteins: An approach to studying the preconcentration of an acidic protein under cationic isotachophoresis. Electrophoresis 2019; 40:1314-1321. [PMID: 30656700 DOI: 10.1002/elps.201800441] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Revised: 01/05/2019] [Accepted: 01/06/2019] [Indexed: 01/28/2023]
Abstract
The objective of this study is to explore an approach for analyzing negatively charged proteins using paper-based cationic ITP. The rationale of electrophoretic focusing the target protein with negative charges under unfavorable cationic ITP condition is to modify the electrophoretic mobility of the target protein through antigen-antibody immunobinding. Cationic ITP was performed on a paper-based analytical device that was fabricated using fiberglass paper. The paper matrix was modified with (3-aminopropyl)trimethoxysilane to minimize sample attraction to the surface for cationic ITP. Negatively charged BSA was used as the model target protein for the cationic ITP experiments. No electrophoretic mobility was observed for BSA-only samples during cationic ITP experimental condition. However, the presence of a primary antibody to BSA significantly improved the electrokinetic behavior of the target protein. Adding a secondary antibody conjugated with amine-rich quantum dots to the sample further facilitated the concentrating effect of ITP, reduced experiment time, and elevated the stacking ratio. Under our optimized experimental conditions, the cationic ITP-based paper device electrophoretically stacked 94% of loaded BSA in less than 7 min. Our results demonstrate that the technique has a broad potential for rapid and cost-effective isotachphoretic analysis of multiplex protein biomarkers in serum samples at the point of care.
Collapse
Affiliation(s)
- Shuang Guo
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | - Thomas Jacroux
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | - Cornelius F Ivory
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | - Lei Li
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, USA
| | - Wen-Ji Dong
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA.,Department of Integrative Physiology and Neuroscience, Washington State University, Pullman, WA, USA
| |
Collapse
|
6
|
Molina DE, Medina AS, Beyenal H, Ivory CF. Design and Finite Element Model of a Microfluidic Platform with Removable Electrodes for Electrochemical Analysis. J Electrochem Soc 2019; 166:B125-B132. [PMID: 31341328 PMCID: PMC6656400 DOI: 10.1149/2.0891902jes] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
A microfluidic platform for hydrodynamic electrochemical analysis was developed, consisting of a poly(methyl methacrylate) chip and three removable electrodes, each housed in 1/16" OD polyether ether ketone tube which can be removed independently for polishing or replacement. The working electrode was a 100-μm diameter Pt microdisk, located flush with the upper face of a 150 μm × 20 μm × 3 cm microchannel, smaller than previously reported for these types of removable electrodes. A commercial leak-less reference electrode was utilized, and a coiled platinum wire was the counter electrode. The platform was evaluated electrochemically by oxidizing a potassium ferrocyanide solution at the working electrode, and a typical limiting current behavior was observed after running linear sweep voltammetry and chronoamperometry, with flow rates 1-6 μL/min. While microdisk channel electrodes have been simulated before using a finite difference method in an ideal 3D geometry, here we predict the limiting current using finite elements in COMSOL Multiphysics 5.3a, which allowed us to easily explore variations in the microchannel geometry that have not previously been considered in the literature. Experimental and simulated currents showed the same trend but differed by 41% in simulations of the ideal geometry, which improved when channel and electrode imperfections were included.
Collapse
|
7
|
Friedrich SM, Burke JM, Liu KJ, Ivory CF, Wang TH. Molecular rheotaxis directs DNA migration and concentration against a pressure-driven flow. Nat Commun 2017; 8:1213. [PMID: 29089494 PMCID: PMC5663963 DOI: 10.1038/s41467-017-01214-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2017] [Accepted: 08/30/2017] [Indexed: 12/23/2022] Open
Abstract
In-line preconcentration techniques are used to improve the sensitivity of microfluidic DNA analysis platforms. The most common methods are electrokinetic and require an externally applied electric field. Here we describe a microfluidic DNA preconcentration technique that does not require an external field. Instead, pressure-driven flow from a fluid-filled microcapillary into a lower ionic strength DNA sample reservoir induces spontaneous DNA migration against the direction of flow. This migratory phenomenon that we call Molecular Rheotaxis initiates in seconds and results in a concentrated DNA bolus at the capillary orifice. We demonstrate the ease with which this concentration method can be integrated into a microfluidic total analysis system composed of in-line DNA preconcentration, size separation, and single-molecule detection. Paired experimental and numerical simulation results are used to delineate the parameters required to induce Molecular Rheotaxis, elucidate the underlying mechanism, and optimize conditions to achieve DNA concentration factors exceeding 10,000 fold. Implementing a nucleic acid preconcentration method can improve the sensitivity of microfluidic analysis systems. Here Friedrich et al. concentrate DNA by many orders of magnitude using pressure-driven flow, which could lead to a simple and practical microanalysis platform.
Collapse
Affiliation(s)
- Sarah M Friedrich
- Biomedical Engineering Department, Johns Hopkins University, Baltimore, MD, 21218, USA
| | | | | | - Cornelius F Ivory
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, 99164, USA.
| | - Tza-Huei Wang
- Biomedical Engineering Department, Johns Hopkins University, Baltimore, MD, 21218, USA. .,Mechanical Engineering Department, Johns Hopkins University, Baltimore, MD, 21218, USA.
| |
Collapse
|
8
|
|
9
|
Bhattarai S, Bottenus D, Ivory CF, Gao AH, Bule M, Garcia-Perez M, Chen S. Simulation of the ozone pretreatment of wheat straw. Bioresour Technol 2015; 196:78-87. [PMID: 26231127 DOI: 10.1016/j.biortech.2015.07.022] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2015] [Revised: 07/02/2015] [Accepted: 07/03/2015] [Indexed: 06/04/2023]
Abstract
Wheat straw is a potential feedstock in biorefinery for sugar production. However, the cellulose, which is the major source of sugar, is protected by lignin. Ozonolysis deconstructs the lignin and makes cellulose accessible to enzymatic digestion. In this study, the change in lignin concentration with different ozonolysis times (0, 1, 2, 3, 5, 7, 10, 15, 20, 30, 60min) was fit to two different kinetic models: one using the model developed by Garcia-Cubero et al. (2012) and another including an outer mass transfer barrier or "cuticle" region where ozone mass transport is reduced in proportion to the mass of unreacted insoluble lignin in the cuticle. The kinetic parameters of two mathematical models for predicting the soluble and insoluble lignin at different pretreatment time were determined. The results showed that parameters derived from the cuticle-based model provided a better fit to experimental results compared to a model without a cuticle layer.
Collapse
Affiliation(s)
- Sujala Bhattarai
- Department of Biological Systems Engineering, Washington State University, Pullman 99164-6120, United States
| | - Danny Bottenus
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, P.O. Box 646515, Pullman, WA 99164-6515, United States
| | - Cornelius F Ivory
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, P.O. Box 646515, Pullman, WA 99164-6515, United States.
| | - Allan Haiming Gao
- Department of Biological Systems Engineering, Washington State University, Pullman 99164-6120, United States
| | - Mahesh Bule
- Department of Biological Systems Engineering, Washington State University, Pullman 99164-6120, United States
| | - Manuel Garcia-Perez
- Department of Biological Systems Engineering, Washington State University, Pullman 99164-6120, United States
| | - Shulin Chen
- Department of Biological Systems Engineering, Washington State University, Pullman 99164-6120, United States
| |
Collapse
|
10
|
Gstoettenmayr D, Quirino J, Ivory CF, Breadmore M. Stacking in a continuous sample flow interface in capillary electrophoresis. J Chromatogr A 2015; 1408:236-42. [DOI: 10.1016/j.chroma.2015.06.040] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2015] [Revised: 06/05/2015] [Accepted: 06/16/2015] [Indexed: 10/23/2022]
|
11
|
Ivory CF. Taylor dispersion in equilibrium gradient focusing at steady state. Electrophoresis 2014; 36:662-7. [PMID: 25521436 DOI: 10.1002/elps.201400409] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2014] [Revised: 11/26/2014] [Accepted: 12/05/2014] [Indexed: 11/11/2022]
Abstract
An analytic expression is presented for the effective dispersion coefficient in the case where a solute is focused in a parabolic flow against a linear gradient in a restoring force. This expression was derived by employing a minor variation on the method of moments used by Aris in his development of the dispersion coefficients for a time-dependent, isocratic system. In the present case, dispersion is controlled by two dimensionless groups, a Peclet number which is proportional to the parabolic component of the flow, and a gradient number which is proportional to the slope of the restoring force. These results confirm that the Aris-Taylor expression for the dispersion coefficient should not be applied in cases where a solute is focused to a stationary steady state.
Collapse
Affiliation(s)
- Cornelius F Ivory
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| |
Collapse
|
12
|
Liu B, Cong Y, Ivory CF. Counterflow isotachophoresis in a monolithic column. J Sep Sci 2014; 37:2395-402. [DOI: 10.1002/jssc.201400392] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2014] [Revised: 06/06/2014] [Accepted: 06/06/2014] [Indexed: 12/29/2022]
Affiliation(s)
- Bingwen Liu
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman WA USA
| | - Yongzheng Cong
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman WA USA
| | - Cornelius F. Ivory
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman WA USA
| |
Collapse
|
13
|
Jacroux T, Bottenus D, Rieck B, Ivory CF, Dong WJ. Cationic isotachophoresis separation of the biomarker cardiac troponin I from a high-abundance contaminant, serum albumin. Electrophoresis 2014; 35:2029-38. [PMID: 24723384 DOI: 10.1002/elps.201400009] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2013] [Revised: 02/27/2014] [Accepted: 03/16/2014] [Indexed: 11/11/2022]
Abstract
Cationic ITP was used to separate and concentrate fluorescently tagged cardiac troponin I (cTnI) from two proteins with similar isoelectric properties in a PMMA straight-channel microfluidic chip. In an initial set of experiments, cTnI was effectively separated from R-Phycoerythrin using cationic ITP in a pH 8 buffer system. Then, a second set of experiments was conducted in which cTnI was separated from a serum contaminant, albumin. Each experiment took ∼10 min or less at low electric field strengths (34 V/cm) and demonstrated that cationic ITP could be used as an on-chip removal technique to isolate cTnI from albumin. In addition to the experimental work, a 1D numerical simulation of our cationic ITP experiments has been included to qualitatively validate experimental observations.
Collapse
Affiliation(s)
- Thomas Jacroux
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | | | | | | | | |
Collapse
|
14
|
Cong Y, Bottenus D, Liu B, Clark SB, Ivory CF. ITP of lanthanides in microfluidic PMMA chip. Electrophoresis 2013; 35:646-53. [DOI: 10.1002/elps.201300382] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2013] [Revised: 10/29/2013] [Accepted: 11/07/2013] [Indexed: 11/06/2022]
Affiliation(s)
- Yongzheng Cong
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman WA USA
| | - Danny Bottenus
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman WA USA
| | - Bingwen Liu
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman WA USA
| | - Sue B. Clark
- Department of Chemistry; Washington State University; Pullman WA USA
| | - Cornelius F. Ivory
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman WA USA
| |
Collapse
|
15
|
Ivory CF, Srivastava SK. Direct current dielectrophoretic simulation of proteins using an array of circular insulating posts. Electrophoresis 2013; 32:2323-30. [PMID: 23361922 DOI: 10.1002/elps.201100115] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2011] [Revised: 06/02/2011] [Accepted: 06/06/2011] [Indexed: 11/07/2022]
Abstract
This paper presents a mathematical model for the manipulation of proteins using insulator-based dielectrophoresis (iDEP) and direct current (DC) electric fields. Simulations via COMSOL v4.1 Multiphysics software are implemented to study the response of moderately sized proteins on a lab-on-a-chip platform. The geometry of the device is incorporated in a model that solves current and mass conservation equations within an array of circular insulating silicon posts embedded in a channel. Both micro- and nano-scale geometries are utilized to investigate the protein concentration distributions in the iDEP device. Our results indicate that the trapping of proteins is independent of the scale with respect to the geometry of a device as long as the applied electric field remains constant. DC voltage dependency on concentration distributions has also been explored in both micro- and nano-scale device geometries. To achieve DEP trapping of the proteins, nano-scale geometry is a better selection, as the voltage necessary to generate the required electric field (2.5 MV/cm) is 10(5) × lower compared with the voltage required to generate the same field in the micro-scale device.
Collapse
Affiliation(s)
- Cornelius F Ivory
- Voiland School of Chemical Engineering and Bioengineering, Washington State University, WA 99l64-27l0, USA
| | | |
Collapse
|
16
|
Smejkal P, Bottenus D, Breadmore MC, Guijt RM, Ivory CF, Foret F, Macka M. Microfluidic isotachophoresis: A review. Electrophoresis 2013; 34:1493-509. [DOI: 10.1002/elps.201300021] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2013] [Revised: 03/06/2013] [Accepted: 03/07/2013] [Indexed: 12/22/2022]
Affiliation(s)
- Petr Smejkal
- ACROSS and School of Chemistry; University of Tasmania; Hobart; Australia
| | - Danny Bottenus
- Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman; WA; USA
| | | | - Rosanne M. Guijt
- ACROSS and School of Pharmacy; University of Tasmania; Hobart; Australia
| | - Cornelius F. Ivory
- Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman; WA; USA
| | - František Foret
- Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic; v.v.i., Brno; Czech Republic
| | - Mirek Macka
- ACROSS and School of Chemistry; University of Tasmania; Hobart; Australia
| |
Collapse
|
17
|
Liu B, Ivory CF. Isotachophoresis with counterflow in an open capillary: Computer simulation and experimental validation. J Sep Sci 2013; 36:1986-95. [DOI: 10.1002/jssc.201300066] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2013] [Revised: 03/20/2013] [Accepted: 03/21/2013] [Indexed: 11/11/2022]
Affiliation(s)
- Bingwen Liu
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman; WA; USA
| | - Cornelius F. Ivory
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman; WA; USA
| |
Collapse
|
18
|
Affiliation(s)
- Derek R. Dixon
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman; USA
| | - Sue B. Clark
- Department of Chemistry; Washington State University; Pullman; USA
| | - Cornelius F. Ivory
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering; Washington State University; Pullman; USA
| |
Collapse
|
19
|
Jubery TZ, Hossan MR, Bottenus DR, Ivory CF, Dong W, Dutta P. A new fabrication technique to form complex polymethylmethacrylate microchannel for bioseparation. Biomicrofluidics 2012; 6:16503-1650313. [PMID: 22396722 PMCID: PMC3293388 DOI: 10.1063/1.3683163] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2011] [Accepted: 01/15/2012] [Indexed: 05/25/2023]
Abstract
Recent studies show that reduction in cross-sectional area can be used to improve the concentration factor in microscale bioseparations. Due to simplicity in fabrication process, a step reduction in cross-sectional area is generally implemented in microchip to increase the concentration factor. But the sudden change in cross-sectional area can introduce significant band dispersion and distortion. This paper reports a new fabrication technique to form a gradual reduction in cross-sectional area in polymethylmethacrylate (PMMA) microchannel for both anionic and cationic isotachophoresis (ITP). The fabrication technique is based on hot embossing and surface modification assisted bonding method. Both one-dimensional and two-dimensional gradual reduction in cross-sectional area microchannels were formed on PMMA with high fidelity using proposed techniques. ITP experiments were conducted to separate and preconcentrate fluorescent proteins in these microchips. Thousand fold and ten thousand fold increase in concentrations were obtained when 10 × and 100 × gradual reduction in cross-sectional area microchannels were used for ITP.
Collapse
|
20
|
Bottenus D, Hossan MR, Ouyang Y, Dong WJ, Dutta P, Ivory CF. Preconcentration and detection of the phosphorylated forms of cardiac troponin I in a cascade microchip by cationic isotachophoresis. Lab Chip 2011; 11:3793-801. [PMID: 21935555 PMCID: PMC3233477 DOI: 10.1039/c1lc20469f] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
This paper describes the detection of a cardiac biomarker, cardiac troponin I (cTnI), spiked into depleted human serum using cationic isotachophoresis (ITP) in a 3.9 cm long poly(methyl methacrylate) (PMMA) microfluidic channel. The microfluidic chip incorporates a 100× cross-sectional area reduction, including a 10× depth reduction and a 10× width reduction, to increase sensitivity during ITP. The cross-sectional area reductions in combination with ITP allowed visualization of lower concentrations of fluorescently labeled cTnI. ITP was performed in both "peak mode" and "plateau mode" and the final concentrations obtained were linear with initial cTnI concentration. We were able to detect and quantify cTnI at initial concentrations as low as 46 ng mL(-1) in the presence of human serum proteins and obtain cTnI concentrations factors as high as ~ 9000. In addition, preliminary ITP experiments including both labeled cTnI and labeled protein kinase A (PKA) phosphorylated cTnI were performed to visualize ITP migration of different phosphorylated forms of cTnI. The different phosphorylated states of cTnI formed distinct ITP zones between the leading and terminating electrolytes. To our knowledge, this is the first attempt at using ITP in a cascade microchip to quantify cTnI in human serum and detect different phosphorylated forms.
Collapse
Affiliation(s)
- Danny Bottenus
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, P.O. Box 642710, Pullman, WA, 99164-2710, U.S.A
| | - Mohammad Robiul Hossan
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99163, U.S.A
| | - Yexin Ouyang
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, P.O. Box 642710, Pullman, WA, 99164-2710, U.S.A
| | - Wen-Ji Dong
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99163, U.S.A
| | - Prashanta Dutta
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99163, U.S.A
| | - Cornelius F. Ivory
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, P.O. Box 642710, Pullman, WA, 99164-2710, U.S.A
| |
Collapse
|
21
|
Bottenus D, Jubery TZ, Ouyang Y, Dong WJ, Dutta P, Ivory CF. 10,000-fold concentration increase of the biomarker cardiac troponin I in a reducing union microfluidic chip using cationic isotachophoresis. Lab Chip 2011; 11:890-8. [PMID: 21416810 PMCID: PMC3289062 DOI: 10.1039/c0lc00490a] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
This paper describes the preconcentration of the biomarker cardiac troponin I (cTnI) and a fluorescent protein (R-phycoerythrin) using cationic isotachophoresis (ITP) in a 3.9 cm long poly(methyl methacrylate) (PMMA) microfluidic chip. The microfluidic chip includes a channel with a 5× reduction in depth and a 10× reduction in width. Thus, the overall cross-sectional area decreases by 50× from inlet (anode) to outlet (cathode). The concentration is inversely proportional to the cross-sectional area so that as proteins migrate through the reductions, the concentrations increase proportionally. In addition, the proteins gain additional concentration by ITP. We observe that by performing ITP in a cross-sectional area reducing microfluidic chip we can attain concentration factors greater than 10,000. The starting concentration of cTnI was 2.3 μg mL⁻¹ and the final concentration after ITP concentration in the microfluidic chip was 25.52 ± 1.25 mg mL⁻¹. To the author's knowledge this is the first attempt at concentrating the cardiac biomarker cTnI by ITP. This experimental approach could be coupled to an immunoassay based technique and has the potential to lower limits of detection, increase sensitivity, and quantify different isolated cTnI phosphorylation states.
Collapse
Affiliation(s)
- Danny Bottenus
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, P.O. Box 642710, Pullman, WA, 99164-2710, USA; Fax: +1 (509) 335-4806
| | - Talukder Zaki Jubery
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, P.O. Box 642710, Pullman, WA, 99164-2710, USA; Fax: +1 (509) 335-4806
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, 99163, USA
| | - Yexin Ouyang
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, P.O. Box 642710, Pullman, WA, 99164-2710, USA; Fax: +1 (509) 335-4806
| | - Wen-Ji Dong
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, P.O. Box 642710, Pullman, WA, 99164-2710, USA; Fax: +1 (509) 335-4806
| | - Prashanta Dutta
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, P.O. Box 642710, Pullman, WA, 99164-2710, USA; Fax: +1 (509) 335-4806
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, 99163, USA
| | - Cornelius F. Ivory
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, P.O. Box 642710, Pullman, WA, 99164-2710, USA; Fax: +1 (509) 335-4806
| |
Collapse
|
22
|
Bottenus D, Jubery TZ, Dutta P, Ivory CF. 10,000-fold concentration increase in proteins in a cascade microchip using anionic ITP by a 3-D numerical simulation with experimental results. Electrophoresis 2011; 32:550-62. [PMID: 21308695 PMCID: PMC3229181 DOI: 10.1002/elps.201000510] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2010] [Revised: 12/02/2010] [Accepted: 12/05/2010] [Indexed: 11/07/2022]
Abstract
This paper describes both the experimental application and 3-D numerical simulation of isotachophoresis (ITP) in a 3.2 cm long "cascade" poly(methyl methacrylate) (PMMA) microfluidic chip. The microchip includes 10 × reductions in both the width and depth of the microchannel, which decreases the overall cross-sectional area by a factor of 100 between the inlet (cathode) and outlet (anode). A 3-D numerical simulation of ITP is outlined and is a first example of an ITP simulation in three dimensions. The 3-D numerical simulation uses COMSOL Multiphysics v4.0a to concentrate two generic proteins and monitor protein migration through the microchannel. In performing an ITP simulation on this microchip platform, we observe an increase in concentration by over a factor of more than 10,000 due to the combination of ITP stacking and the reduction in cross-sectional area. Two fluorescent proteins, green fluorescent protein and R-phycoerythrin, were used to experimentally visualize ITP through the fabricated microfluidic chip. The initial concentration of each protein in the sample was 1.995 μg/mL and, after preconcentration by ITP, the final concentrations of the two fluorescent proteins were 32.57 ± 3.63 and 22.81 ± 4.61 mg/mL, respectively. Thus, experimentally the two fluorescent proteins were concentrated by over a factor of 10,000 and show good qualitative agreement with our simulation results.
Collapse
Affiliation(s)
- Danny Bottenus
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | | | | | | |
Collapse
|
23
|
Abstract
An increasing demand for products such as tissues, proteins, and antibodies from mammalian cell suspension cultures is driving interest in increasing production through high-cell density bioreactors. The centrifugal bioreactor (CCBR) retains cells by balancing settling forces with surface drag forces due to medium throughput and is capable of maintaining cell densities above 10(8) cells/mL. This article builds on a previous study where the fluid mechanics of an empty CCBR were investigated showing fluid flow is nonuniform and dominated by Coriolis forces, raising concerns about nutrient and cell distribution. In this article, we demonstrate that the previously reported Coriolis forces are still present in the CCBR, but masked by the presence of cells. Experimental dye injection observations during culture of 15 microm hybridoma cells show a continual uniform darkening of the cell bed, indicating the region of the reactor containing cells is well mixed. Simulation results also indicate the cell bed is well mixed during culture of mammalian cells ranging in size from 10 to 20 microm. However, simulations also allow for a slight concentration gradient to be identified and attributed to Coriolis forces. Experimental results show cell density increases from 0.16 to 0.26 when centrifugal force is doubled by increasing RPM from 650 to 920 at a constant inlet velocity of 6.5 cm/s; an effect also observed in the simulation. Results presented in this article indicate cells maintained in the CCBR behave as a high-density fluidized bed of cells providing a homogeneous environment to ensure optimal growth conditions.
Collapse
Affiliation(s)
- Christopher J Detzel
- Gene & Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164, USA
| | | | | |
Collapse
|
24
|
Abstract
This paper is part of our continued effort to understand the underlying principles of dynamic field gradient focusing. In this investigation, we examined three problems associated with the use of a semi-permeable membrane. First, the influence of steric and ionic exclusion of current carrying ions through the membrane was examined. It was found that resistance to the transport of ions across the membrane resulted in a shallowing of the electric field profile and an increase in the size of the defocusing zone, which is where the slope of the electric field is reversed so that it disperses rather than concentrates solutes. These problems could be reduced by using a membrane with large pores relative to the size of the buffering ions and completely void of fixed charges. Next, a numerical simulation was used to investigate concentration polarization of protein onto the surface of the membrane. Due to the presence of a transverse electric field, species were pulled toward the membrane. If the membrane is restrictive to those species, a concentrated, polarized layer will form on the surface. The simulation showed that by decreasing the channel to a depth of 20 microm, the concentrated region next to the membrane could be reduced. Finally, it was found that changes in column volume due to loss of membrane structural integrity could be mitigated by including a porous ceramic support. The variation in peak elution times was decreased from greater than 20% to less than 3%.
Collapse
Affiliation(s)
- Jeffrey M Burke
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164-2710, USA
| | | |
Collapse
|
25
|
Burke JM, Smith CD, Ivory CF. Development of a membrane-less dynamic field gradient focusing device for the separation of low-molecular-weight molecules. Electrophoresis 2010; 31:902-9. [PMID: 20191553 DOI: 10.1002/elps.200900589] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Dynamic field gradient focusing uses an electric field gradient generated by controlling the voltage profile of an electrode array to separate and concentrate charged analytes according to their individual electrophoretic mobilities. This study describes a new instrument in which the electrodes have been placed within the separation channel. The major challenge faced with this device is that when applied voltages to the electrodes are larger than the redox potential of water, electrolysis will occur, producing hydrogen ions (H+) plus oxygen gas on the anodes and hydroxide (OH(-)) plus hydrogen gas on the cathodes. The resulting gas bubbles and pH excursions can cause problems with system performance and reproducibility. An on-column, degassing system that can remove gas bubbles "on-the-fly" is described. In addition, the use of a high capacity, low-conductivity buffer to address the problem of the pH shift that occurs due to the production of H+ on the anodes is illustrated. Finally, the successful separation of three, low-molecular-weight dyes (amaranth, bromophenol blue and methyl red) is described.
Collapse
Affiliation(s)
- Jeffrey M Burke
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164-2710, USA
| | | | | |
Collapse
|
26
|
Burke JM, Huang Z, Ivory CF. Simultaneous separation of negatively and positively charged species in dynamic field gradient focusing using a dual polarity electric field. Anal Chem 2009; 81:8236-43. [PMID: 19722517 DOI: 10.1021/ac901634y] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Dynamic field gradient focusing (DFGF) utilizes an electric field gradient established by a computer-controlled electrode array to separate and concentrate charged analytes at unique axial positions. Traditionally, DFGF has been restricted to the analysis of negatively charged species due to limitations in the software of our voltage controller. This paper introduces a new voltage controller capable of operating under normal polarity (positive potentials applied to the electrode array) and reversed polarity (negative potentials applied to the electrode array) for the separation of negatively and positively charged analytes, respectively. The experiments conducted under normal polarity and reversed polarity illustrate the utility of the new controller to perform reproducible DFGF separations (elution times showing less than 1% run-to-run variation) over a wide pH range (3.08 to 8.5) regardless of the protein charge. A dual polarity experiment is then shown in which the separation channel has been divided into normal polarity and reversed polarity regions. This simultaneous separation of negatively charged R-phycoerythrin (R-PE) and positively charged cytochrome c (CYTC) within the same DFGF apparatus is shown.
Collapse
Affiliation(s)
- Jeffrey M Burke
- Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | | | | |
Collapse
|
27
|
Detzel CJ, Thorson MR, Van Wie BJ, Ivory CF. A study of the Coriolis effect on the fluid flow profile in a centrifugal bioreactor. Biotechnol Prog 2009; 25:1025-34. [PMID: 19455639 DOI: 10.1002/btpr.183] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Increasing demand for tissues, proteins, and antibodies derived from cell culture is necessitating the development and implementation of high cell density bioreactors. A system for studying high density culture is the centrifugal bioreactor (CCBR), which retains cells by increasing settling velocities through system rotation, thereby eliminating diffusional limitations associated with mechanical cell retention devices. This article focuses on the fluid mechanics of the CCBR system by considering Coriolis effects. Such considerations for centrifugal bioprocessing have heretofore been ignored; therefore, a simpler analysis of an empty chamber will be performed. Comparisons are made between numerical simulations and bromophenol blue dye injection experiments. For the non-rotating bioreactor with an inlet velocity of 4.3 cm/s, both the numerical and experimental results show the formation of a teardrop shaped plume of dye following streamlines through the reactor. However, as the reactor is rotated, the simulation predicts the development of vortices and a flow profile dominated by Coriolis forces resulting in the majority of flow up the leading wall of the reactor as dye initially enters the chamber, results are confirmed by experimental observations. As the reactor continues to fill with dye, the simulation predicts dye movement up both walls while experimental observations show the reactor fills with dye from the exit to the inlet. Differences between the simulation and experimental observations can be explained by excessive diffusion required for simulation convergence, and a slight density difference between dyed and un-dyed solutions. Implications of the results on practical bioreactor use are also discussed.
Collapse
Affiliation(s)
- Christopher J Detzel
- Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164-2710, USA
| | | | | | | |
Collapse
|
28
|
Oh YJ, Bottenus D, Ivory CF, Han SM. Impact of leakage current and electrolysis on FET flow control and pH changes in nanofluidic channels. Lab Chip 2009; 9:1609-17. [PMID: 19458870 PMCID: PMC2910628 DOI: 10.1039/b816384g] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
We have fabricated multiple-internal-reflection Si infrared waveguides integrated with an array of nanochannels sealed with an optically transparent top cover. The channel walls consist of a thin layer of SiO2 for electrical insulation, and gate electrodes surround the channel sidewalls and bottom to manipulate their surface charge and zeta-potential in a fluidic field effect transistor (FET) configuration. This nanofluidic device is used to probe the transport of charged molecules (Alexa 488) and to measure the pH shift in nanochannels in response to an electrical potential applied to the gate. During gate biasing for FET operation, laser-scanning confocal fluorescence microscopy (LS-CFM) is used to visualize the flow of fluorescent dye molecules (Alexa 488), and multiple internal reflection-Fourier transform infrared spectroscopy (MIR-FTIRS) is used to probe the characteristic vibrational modes of fluorescein pH indicator and measure the pH shift. The electroosmotic flow of Alexa 488 is accelerated in response to a negative gate bias, whereas its flow direction is reversed in response to a positive gate bias. We also measure that the pH of buffered electrolyte solutions shifts by as much as a pH unit upon applying the gate bias. With prolonged application of gate bias, however, we observe that the initial response in flow speed and direction as well as pH shift becomes reversed. We attribute these anomalous flow and pH shift characteristics to a leakage current that flows from the Si gate through the thermally grown SiO2 to the electrolyte solution.
Collapse
Affiliation(s)
- Youn-Jin Oh
- Department of Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, New Mexico, 87131, USA. Fax: +1 (505) 277 5443; Tel: +1 (505) 277 3118
| | - Danny Bottenus
- Department of Chemical Engineering, Washington State University, Pullman, WA, 99164, USA
| | - Cornelius F. Ivory
- Department of Chemical Engineering, Washington State University, Pullman, WA, 99164, USA
| | - Sang M. Han
- Department of Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, New Mexico, 87131, USA. Fax: +1 (505) 277 5443; Tel: +1 (505) 277 3118
| |
Collapse
|
29
|
Oh YJ, Garcia AL, Petsev DN, Lopez GP, Brueck SRJ, Ivory CF, Han SM. Effect of wall-molecule interactions on electrokinetic transport of charged molecules in nanofluidic channels during FET flow control. Lab Chip 2009; 9:1601-8. [PMID: 19458869 DOI: 10.1039/b901382m] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The interactions between charged molecules and channel surfaces are expected to significantly influence the electrokinetic transport of molecules and their separations in nanochannels. This study reports the effect of wall-molecule interactions on flow control of negatively charged Alexa 488 and positively charged Rhodamine B dye molecules in an array of nanochannels (100 nm wx 500 nm dx 14 mm l) embedded in fluidic field effect transistors (FETs). For FET flow control, a third electrical potential, known as a gate bias, is applied to the channel walls to manipulate their zeta-potential. Electroosmotic flow of charged dye molecules is accelerated or reversed according to the polarity and magnitude of the gate bias. During FET flow control, we monitor how the electrostatic interaction between charged dye molecules and channel walls affects the apparent velocity of molecules, using laser-scanning confocal fluorescence microscopy. We observe that the changes in flow speed and direction of negatively charged Alexa 488 is much more pronounced than that of positively charged Rhodamine B in response to the gate bias that causes either repulsive or attractive electrostatic interactions. This observation is supported by calculations of concentration-weighted velocity profiles of the two dye molecules during FET flow control. The velocity profile of negatively charged Alexa 488 is much more pronounced at the center of each nanochannel than near its walls since Alexa 488 molecules are repelled from negatively charged channel walls. This pronounced center velocity further responds to the gate bias, increasing the average velocity by as much as 23% when -30 V is applied to the gate (zeta-potential = -80.6 mV). In contrast, the velocity profile of positively charged Rhodamine B is dispersed over the entire channel width due to dye-wall attraction and adsorption. Our experimental observations and calculations support the hypothesis that valence-charge-dependent electrostatic interaction and its manipulation by the gate bias would enhance molecular separations of differentially charged molecules in nanofluidic FETs.
Collapse
Affiliation(s)
- Youn-Jin Oh
- Department of Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, New Mexico 87131, USA
| | | | | | | | | | | | | |
Collapse
|
30
|
Abstract
Lab-on-a-chip (LOC) technology provides a powerful platform for simultaneous separation, purification, and identification of low concentration multicomponent mixtures. As the characteristic dimension of LOC devices decreases down to the nanoscale, the possibility of containing an entire lab on a single chip is becoming a reality. This research examines one of the unique physical characteristics of nanochannels, in which native pH shifts occur. As a result of the electrical double layer taking up a significant portion of a 100 nm wide nanochannel, electroneutrality no longer exists in the channel causing a radial pH gradient. This work describes experimentally observed pH shifts as a function of ionic strength using the fluorescent pH indicator 5-(and-6)-carboxy SNARF-1 and compares it to a model developed using Comsol Multiphysics. At low ionic strengths (approximately 3 mM) the mean pH shift is approximately 1 pH unit whereas at high ionic strengths (approximately 150 mM) the mean pH shift is reduced to 0.1 pH units. An independent analysis using fluorescein pH indicator is also presented supporting these findings. Two independent non-linear simulations coupling the Nernst-Planck equation describing transport in ionic solutions subjected to an electric field and Poisson's equation to describe the electric field as it relates to the charge distribution are solved using a finite element solver. In addition, the effects of chemical activities are considered in the simulations. The first numerical simulation is based on a surface zeta-potential which significantly underestimates the experimental results for most ionic strengths. A modified model assuming that SNARF and fluorescein molecules are able to diffuse into the hydrolyzed SiO2 phase, and in the case of the SNARF molecule, able to bind to neutral regions of the SiO2 phase agrees quantitatively with experimental results.
Collapse
Affiliation(s)
- Danny Bottenus
- Department of Chemical Engineering, Washington State University, P.O. Box 642710, Pullman, WA, 99164-2710, USA
| | - Youn-Jin Oh
- Department of Chemical and Nuclear Engineering, Center for High Technology Materials, University of New Mexico, Albuquerque, New Mexico, 87131, USA
| | - Sang M. Han
- Department of Chemical and Nuclear Engineering, Center for High Technology Materials, University of New Mexico, Albuquerque, New Mexico, 87131, USA
| | - Cornelius F. Ivory
- Department of Chemical Engineering, Washington State University, P.O. Box 642710, Pullman, WA, 99164-2710, USA
- ; Fax: +1 509 335-4806
| |
Collapse
|
31
|
|
32
|
Ansell RJ, Tuñón PG, Wang Y, Myers P, Ivory CF, Keen JN, Findlay JBC. Electrophoretic field gradient focusing with on-column detection by fluorescence quenching. Analyst 2009; 134:226-9. [DOI: 10.1039/b815446e] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
33
|
|
34
|
Abstract
Dynamic field gradient focusing uses an electric field gradient to separate and concentrate proteins in native buffers. A prototype preparative-scale dynamic field gradient focusing apparatus reproducibly separated hemoglobin and bovine serum albumin with a mean resolution of 2.64+/-0.503. Run-to-run variations in the hemoglobin's focal point and peak width appeared to be related to fluctuations in the shape of the electric field, rather than the 5% accuracy of the pump that provided the counter-flow in the separation annulus. The variation in the electric field gradient was probably due to the formation and expansion of an ion-depleted region at the top of the separation annulus.
Collapse
Affiliation(s)
- Noah I Tracy
- School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164-2710, USA
| | | |
Collapse
|
35
|
Shim J, Dutta P, Ivory CF. Effects of ampholyte dissociation constants on protein separation in on-chip isoelectric focusing. J Nanosci Nanotechnol 2008; 8:3719-3728. [PMID: 19051929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Numerical simulations are presented for ampholyte-based isoelectric focusing in 2D microgeometries. In this study, model proteins are focused in the presence of 25 biprotic ampholytes under an applied electric field. Each protein is considered as a simple polypeptide having ten charge states, while the biprotic ampholytes are selected to generate a shallow pH range of 6 to 9. Straight and contraction-expansion microchannels are considered here, and a nominal electric field of 300 V/cm is maintained for separation of proteins. Six distinct values of deltapKs between 1 and 3.5 are investigated for ampholytes to form pH profiles in a 1 cm long microchannel. Simulation results show that relatively larger values of deltapK(deltapK > 3) are required to form stepless pH profiles in the system. The peak heights and differential resolutions of focused proteins are much higher for lower values of deltapK for which a stepped pH profile is evident. For each protein, the time it takes for the two edges of a peak to merge increases linearly with deltapK, while the focusing time goes up exponentially with increasing deltapK. Both merging and focusing times of protein are higher for contraction-expansion microchannel than those of straight microchannel. For a particular value of deltapK, the contracted "Zoom" region of contraction-expansion channel is able to form more tightly focused bands than the expanded region.
Collapse
Affiliation(s)
- Jaesool Shim
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920, USA
| | | | | |
Collapse
|
36
|
|
37
|
Abstract
Dynamic field gradient focusing (DFGF) separates and concentrates proteins in native buffers, where proteins are most soluble, using a computer-controlled electric field gradient which lets the operator adjust the pace and resolution of the separation in real-time. The work in this paper assessed whether DFGF could be scaled up from microgram analytical-scale protein loads to milligram preparative-scale loads. Linear modeling of the electric potential, protein transport, and heat transfer simulated the performance of a preparative-scale DFGF instrument. The electric potential model showed where the electrodes should be placed to optimize the shape and strength of the electric field gradient. Results from the protein transport model suggested that in 10 min the device should separate 10 mg each of two proteins whose electrophoretic mobilities differ by 5 x. Proteins with electrophoretic mobilities differing by only 5% should separate in 3 h. The heat transfer model showed that the preparative DFGF design could dissipate 1 kW of Joule heat while keeping the separation chamber at 25 degrees C. Model results pointed to DFGF successfully scaling up by 1000 x using the proposed instrument design.
Collapse
Affiliation(s)
- Noah I Tracy
- School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164-2710, USA
| | | |
Collapse
|
38
|
Abstract
Dynamic field gradient focusing (DFGF) is an equilibrium gradient method that utilizes an electric field gradient to simultaneously separate and concentrate charged analytes based on their individual electrophoretic mobilities. This work describes the use of a 2-D nonlinear, numerical simulation to examine the impact of voltage loss from the electrodes to the separation channel, termed voltage degradation, and distortions in the electric field on the performance of DFGF. One of the design parameters that has a large impact on the degree of voltage degradation is the placement of the electrodes in relation to the separation channel. The simulation shows that a distance of about 3 mm from the electrodes to the separation channel gives the electric field profile with least amount of voltage degradation. The simulation was also used to describe the elution of focused protein peaks. The simulation shows that elution under constant electric field gradient gives better performance than elution through shallowing of the electric field. Qualitative agreement between the numerical simulation and experimental results is shown. The simulation also illustrates that the presence of a defocusing region at the cathodic end of the separation channel causes peak dispersion during elution. The numerical model is then used to design a system that does not suffer from a defocusing region. Peaks eluted under this design experienced no band broadening in our simulations. Preliminary experimental results using the redesigned chamber are shown.
Collapse
Affiliation(s)
- Jeffrey M Burke
- School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | | |
Collapse
|
39
|
|
40
|
Oh YJ, Gamble TC, Leonhardt D, Chung CH, Brueck SRJ, Ivory CF, Lopez GP, Petsev DN, Han SM. Monitoring FET flow control and wall adsorption of charged fluorescent dye molecules in nanochannels integrated into a multiple internal reflection infrared waveguide. Lab Chip 2008; 8:251-8. [PMID: 18231663 DOI: 10.1039/b711682a] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Using Si as the substrate, we have fabricated multiple internal reflection infrared waveguides embedded with a parallel array of nanofluidic channels. The channel width is maintained substantially below the mid-infrared wavelength to minimize infrared scattering from the channel structure and to ensure total internal reflection at the channel bottom. A Pyrex slide is anodically bonded to the top of the waveguide to seal the nanochannels, while simultaneously enabling optical access in the visible range from the top. The Si channel bottom and sidewalls are thermally oxidized to provide an electrically insulating barrier, and the Si substrate surrounding the insulating SiO(2) layer is selectively doped to function as a gate. For fluidic field effect transistor (FET) control, a DC potential is applied to the gate to manipulate the surface charge on SiO(2) channel bottom and sidewalls and therefore their zeta-potential. Depending on the polarity and magnitude, the gate potential can accelerate, decelerate, or reverse the flow. Here, we demonstrate that this nanofluidic infrared waveguide can be used to monitor the FET flow control of charged, fluorescent dye molecules during electroosmosis by multiple internal reflection Fourier transform infrared spectroscopy. Laser scanning confocal fluorescence microscopy is simultaneously used to provide a comparison and verification of the IR analysis. Using the infrared technique, we probe the vibrational modes of dye molecules, as well as those of the solvent. The observed infrared absorbance accounts for the amount of dye molecules advancing or retracting in the nanochannels, as well as adsorbing to and desorbing from the channel bottom and sidewalls.
Collapse
Affiliation(s)
- Youn-Jin Oh
- Department of Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, New Mexico 87131, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Abstract
A linear model is used to show that dynamic field gradient focusing (DFGF) can be scaled to preparative capacity, approximately O (10 mgs). This paper explains how the preparative-scale DFGF apparatus was designed and fabricated. Scaled-down experiments and mathematical modeling guided material selection and design changes during construction to increase the probability that the prototype preparative-scale DFGF apparatus would perform as intended. The finished prototype successfully focused bovine hemoglobin from an initial concentration of 6.82 to 15 mg/mL and allowed for 86% recovery of injected protein.
Collapse
Affiliation(s)
- Noah I Tracy
- School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164, USA
| | | | | |
Collapse
|
42
|
Tuñón PG, Wang Y, Myers P, Bartle KD, Bowhill L, Ivory CF, Ansell RJ. Electrophoretic field gradient focusing: An investigation of the experimental parameters. Electrophoresis 2008; 29:457-65. [DOI: 10.1002/elps.200700443] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
43
|
Harrison SLM, Ivory CF. Prediction of the location of stationary steady-state zone positions in counterflow isotachophoresis performed under constant voltage in a vortex-stabilized annular column. J Sep Sci 2007; 30:3255-61. [PMID: 18008279 PMCID: PMC2921190 DOI: 10.1002/jssc.200700243] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A theoretical model is presented and an analytical expression derived to predict the locations of stationary steady-state zone positions in ITP as a function of current for a straight channel under a constant applied voltage. Stationary zones may form in the presence of a countercurrent flow whose average velocity falls between that of a pure leader zone and of a pure trailer zone. A comparison of model predictions with experimental data from an anionic system shows that the model is able to predict the location of protein zones with reasonable accuracy once the ITP stack has formed. This result implies that an ITP stack can be precisely directed by the operator to specific positions in a channel whence portions of the stack can be removed or redirected for further processing or analysis.
Collapse
Affiliation(s)
- Schurie L M Harrison
- School of Chemical Engineering and Bioengineering, Washington State University, Pullman 99164-2710, USA
| | | |
Collapse
|
44
|
Abstract
This paper reports a protocol that improves the resolving power of isoelectric focusing (IEF) in a polymeric microfluidic chip. This method couples several stages of IEF in series by first focusing proteins in a straight channel using broad-range ampholytes and then refocusing segments of the first channel into secondary channels that branch from the first one at T-junctions. Experiments demonstrate that several fluorescent proteins that had focused within a segment of the straight channel in the first stage were refocused at significantly higher resolution due to the shallower pH gradient and higher electrical field gradient. Two variants of green fluorescent protein from the second-stage IEF fractionation were further separated in a third stage. Three stages of IEF were completed in less than 25 min at electric field strengths ranging from 50 to 214 V/cm.
Collapse
Affiliation(s)
- Huanchun Cui
- Department of Chemical Engineering and School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, USA
| | | | | | | |
Collapse
|
45
|
Abstract
True moving bed electrophoresis has been shown to be an effective technique for the bench-scale separation of enantiomers, and it is desired to increase the maximum possible throughput attainable with the process by using electric field gradients. Homatropine enantiomer separations were performed and results using a stepped electric field gradient were compared to those using a traditional non-gradient separation. In order to accomplish this, a newly designed stator was constructed for use with the Vortex-Stabilized Electrophoresis Apparatus that has three sets of electrode housings, one set at both ends and one in the middle of the chamber. There were several problems related to the membranes used at the middle electrode. The dialysis membranes were permeable to the homatropine enantiomers, and while a switch to anion exchange membranes prevented the permeation of the homatropine, this caused a pH shift that interrupted binding to the hydroxypropyl-ss-cyclodextrin chiral selector. These problems prevented any meaningful data from being collected using homatropine enantiomers, and due to this, a proof of concept study was conducted using two bovine proteins. The separations using fluorescein-labeled BSA and bovine hemoglobin showed that a 63% increase in the maximum processing rate was attainable. The maximum throughput using the non-gradient process was 30.6 mg/h and the maximum was 50.0 mg/h using an electric field gradient that was 10% lower than the non-gradient field in section II and 10% higher in section III.
Collapse
Affiliation(s)
- Brian M Thome
- Department of Chemical Engineering, Washington State University, WA 99164-2710, USA
| | | |
Collapse
|
46
|
Abstract
This paper reports both the experimental application and 2-D simulation of ITP of proteins in a networked microfluidic chip. Experiments demonstrate that a mixture of three fluorescent proteins can be concentrated and stacked into adjacent zones of pure protein under a constant voltage of 100 V over a 2 cm long microchannel. Measurements of the isotachophoretic velocity of the moving zones demonstrates that, during ITP under a constant voltage, the zone velocity decreases as more of the channel is occupied by the terminating electrolyte. A 2-D ITP model based on the Nernst-Planck equations illustrates the stacking and separation features of ITP using simulations of three virtual proteins. The self-sharpening behavior of ITP zones dispersed by a T-junction is clearly demonstrated both by experiment and by simulation. Comparison of 2-D simulations of ITP and zone electrophoresis (ZE) confirms that ZE lacks the ability to resharpen protein zones after they pass through a T-junction.
Collapse
Affiliation(s)
- Huanchun Cui
- School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164-2710, USA
| | | | | |
Collapse
|
47
|
Abstract
A 2-D finite-volume model is developed to simulate nonlinear IEF in complex microgeometries. This mathematical model is formulated based on the mass conservation and ionic dissociation relations of amphoteric macromolecules, charge conservation, and the electroneutrality condition. Based on the 2-D model, three different separation cases are studied: an IPG in a planar channel, an ampholyte-based pH gradient in a planar channel, and an ampholyte-based pH gradient in a contraction-expansion channel. In the IPG case, cacodylic acid (pK(1) = 6.21) and Tris (pK(1) = 8.3) are used as the acid and base, respectively, to validate the 2-D IEF model. In the ampholyte-based pH gradient cases, IEF is performed in the pH range, 6.21-8.3 using 10 ampholytes in the planar channel and 20 ampholytes in the contraction-expansion channel. The numerical results reveal different focusing efficiencies and resolution in the narrow and wide sections of the contraction-expansion channel. To explain this, the expressions for separation resolution and peak concentrations of separands in the contraction-expansion channel are presented in terms of the channel shape factor. In a 2-D planar channel, a focused band remains straight all the time. However, in a contraction-expansion channel, initially straight bands take on a crescent profile as they pass through the trapezoidal sections joining the contraction and expansion sections.
Collapse
Affiliation(s)
- Jaesool Shim
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920, USA
| | | | | |
Collapse
|
48
|
Abstract
This paper describes an automated electric valve system designed to reduce dispersion and sample loss into a side channel when an electrokinetically mobilized concentration zone passes a T-junction in a networked microfluidic chip. One way to reduce dispersion is to control current streamlines since charged species are driven along them in the absence of electroosmotic flow. Computer simulations demonstrate that dispersion and sample loss can be reduced by applying a constant additional electric field in the side channel to straighten current streamlines in linear electrokinetic flow (zone electrophoresis). This additional electric field was provided by a pair of platinum microelectrodes integrated into the chip in the vicinity of the T-junction. Both simulations and experiments of this electric valve with constant valve voltages were shown to provide unsatisfactory valve performance during nonlinear electrophoresis (isotachophoresis). On the basis of these results, however, an automated electric valve system was developed with improved valve performance. Experiments conducted with this system showed decreased dispersion and increased reproducibility as protein zones isotachophoretically passed the T-junction. Simulations of the automated electric valve offer further support that the desired shape of current streamlines was maintained at the T-junction during isotachophoresis. Valve performance was evaluated at different valve currents based on statistical variance due to dispersion. With the automated control system, two integrated microelectrodes provide an effective way to manipulate current streamlines, thus acting as an electric valve for charged species in electrokinetic separations.
Collapse
Affiliation(s)
- Huanchun Cui
- School of Chemical Engineering and Bioengineering and School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, USA
| | | | | | | |
Collapse
|
49
|
|
50
|
Thome BM, Ivory CF. Increasing the scale of true moving bed electrophoretic separations using filtration to reduce solvent volumetric flows between sections II and III. J Chromatogr A 2007; 1138:291-300. [PMID: 17097668 DOI: 10.1016/j.chroma.2006.10.080] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2006] [Revised: 10/26/2006] [Accepted: 10/30/2006] [Indexed: 11/21/2022]
Abstract
Over the past decade the moving bed process has become a commonly used tool for the continuous separation of chiral compounds, and its recent application to electrophoretic separations allows the technique to be used as a model system for moving bed method improvements. Much of the recent research on moving bed separations has focused on improving the technique's efficiency and increasing the maximum attainable throughput. This paper presents a novel method for reducing or reversing the increases in tailing that stem from the addition of the feed stream in a moving bed process by adding a filtration unit which retains the products while removing fluid from the boundary between the sections above and below the feed stream. This filtration-enhanced moving bed process was applied to a true moving bed (TMB) electrophoresis separation in the Vortex Stabilized Electrophoresis Apparatus, and its effect on a homatropine enantiomer separation was studied. Experiments showed that there is a 2.4-fold increase in the homatropine processing rate when 0.5 ml/h of water is removed through a reverse osmosis filter at the boundary between the sections above and below the feed stream. In order to further understand the process, filtration-enhanced TMB (FE-TMB) was also analyzed using a linear model of the system which shows that the 99% purity operating region of the separation is greatly increased even with moderate permeate flowrates.
Collapse
Affiliation(s)
- Brian M Thome
- Department of Chemical Engineering, Washington State University, 118 Dana Hall, Pullman, WA 99164-2710, USA
| | | |
Collapse
|