1
|
Oh SJ, Jeong MH, Kang YR, Lee CG, Kim H, Kye YU, Park MT, Baek JH, Kim JK, Kim JS, Jeong SK, Jo WS. Automated system for establishing standard radiation dose-response curves and dose estimation for the Korean population. Sci Rep 2025; 15:10639. [PMID: 40148494 PMCID: PMC11950513 DOI: 10.1038/s41598-025-94678-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Accepted: 03/17/2025] [Indexed: 03/29/2025] Open
Abstract
Biological dosimetry is crucial for estimating the doses from biological samples and guiding medical interventions for accidental radiation exposure. This study aimed to derive rapid and precise dose estimates using a dicentric chromosome assay. To address the challenges of manual scoring of dicentric chromosomes, we upgraded an automatic system aimed at enhancing the precision of dicentric chromosome detection while reducing the need for human intervention. We collected blood from 30 individuals aged 20-67 years to create 30 dose-response curves aiming to investigate the differences in responses among individuals. To validate dose-estimate accuracy within a 95% confidence interval, blinded samples were categorized into three groups according to the radiation dose as follows: ≥2, ≤ 1, and 0.1 Gy. When scoring dicentric chromosomes without human review and constructing a dose-response curve, individual differences were observed. For doses ≤ 1 Gy, the standard root formula was effective; conversely, for doses ≥ 2 Gy, the regression deep neural network proved to be more ac-curate. Our developed program allowed for the rapid analysis of a large volume of dicentric chromosome images.
Collapse
Affiliation(s)
- Su Jung Oh
- Dongnam Institute of Radiological and Medical Sciences (DIRAMS), 40 Jwadong-gil, Jangan-eup, Gijang-gun, Busan, 46033, Republic of Korea
| | - Min Ho Jeong
- Department of Microbiology, Dong-A University College of Medicine, Daeshingongwon-gil 32, Seo-gu, Busan, 49236, Republic of Korea
| | - Yeong-Rok Kang
- Dongnam Institute of Radiological and Medical Sciences (DIRAMS), 40 Jwadong-gil, Jangan-eup, Gijang-gun, Busan, 46033, Republic of Korea
| | - Chang Geun Lee
- Dongnam Institute of Radiological and Medical Sciences (DIRAMS), 40 Jwadong-gil, Jangan-eup, Gijang-gun, Busan, 46033, Republic of Korea
| | - HyoJin Kim
- Dongnam Institute of Radiological and Medical Sciences (DIRAMS), 40 Jwadong-gil, Jangan-eup, Gijang-gun, Busan, 46033, Republic of Korea
| | - Yong Uk Kye
- Department of Microbiology, Dong-A University College of Medicine, Daeshingongwon-gil 32, Seo-gu, Busan, 49236, Republic of Korea
| | - Moon-Taek Park
- Dongnam Institute of Radiological and Medical Sciences (DIRAMS), 40 Jwadong-gil, Jangan-eup, Gijang-gun, Busan, 46033, Republic of Korea
| | - Jeong-Hwa Baek
- Dongnam Institute of Radiological and Medical Sciences (DIRAMS), 40 Jwadong-gil, Jangan-eup, Gijang-gun, Busan, 46033, Republic of Korea
| | - Jung-Ki Kim
- Dongnam Institute of Radiological and Medical Sciences (DIRAMS), 40 Jwadong-gil, Jangan-eup, Gijang-gun, Busan, 46033, Republic of Korea
| | - Joong Sun Kim
- College of Veterinary Medicine and BK21 Plus Project Team, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju, 61186, Republic of Korea
| | - Soo Kyung Jeong
- Dongnam Institute of Radiological and Medical Sciences (DIRAMS), 40 Jwadong-gil, Jangan-eup, Gijang-gun, Busan, 46033, Republic of Korea.
| | - Wol Soon Jo
- Dongnam Institute of Radiological and Medical Sciences (DIRAMS), 40 Jwadong-gil, Jangan-eup, Gijang-gun, Busan, 46033, Republic of Korea.
| |
Collapse
|
2
|
Vinnikov V, Kochanova D, Vigašová K, Gulati S, Durdík M, Košík P, Marková E, Jakl L, Zastko L, Kontrišová K, Belyaev I. Dose-response curve for induction of unstable chromosome aberrations by 6 MV linear accelerator photons: Analysis of intra-experimental variations. MUTATION RESEARCH. GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS 2025; 902:503849. [PMID: 40044372 DOI: 10.1016/j.mrgentox.2025.503849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2024] [Revised: 01/16/2025] [Accepted: 01/17/2025] [Indexed: 05/13/2025]
Abstract
Cytogenetic biodosimetry relies on dose-response curves (DRCs) for each type of radiation that can cause a radiation emergency. We have constructed a DRC based on the dicentric assay. Blood samples from four healthy volunteers were irradiated with acute 6 MV linac photons, 0.46-4.55 Gy; 0.68 and 1.37 Gy doses were used in the 'blind' validation study. Lymphocytes were cultured with variations in time delay in mitogenic stimulation after irradiation (2 vs. 16 h) and mitotic arrest by colchicine (3.5 vs. 16 h). Aberrations were scored in the first division metaphases, ensured by fluorescence-plus-Giemsa staining. DRCs for dicentrics and dicentrics plus centric rings were efficiently fitted using the linear-quadratic model. We show, for the first time, that neither prolonged mitotic arrest nor delayed mitogenic stimulation has any effect on DRC. However, the latter factor caused a significant increase in the yield of the second division metaphase in culture. Inter-donor differences in the DRC for aberrations were not large, but individual changes in the frequencies of second-division cells were highly variable. In the validation study, the DRC combined from all experimental series provided dose estimates that were as accurate as those, obtained using the donors' individual or culture-type specific DRCs. The DRC coefficients in present study were slightly higher than those reported previously for linac beams and close to values for orthovoltage X-rays. Further cytogenetic studies of megavoltage radiation beams require stringent standardization of experimental conditions.
Collapse
Affiliation(s)
- Volodymyr Vinnikov
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Centre of Slovak Academy of Science, Bratislava, Slovak Republic, BMC SAV, Dúbravská Cesta 9, Bratislava 84505, Slovak Republic.
| | - Dominika Kochanova
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Centre of Slovak Academy of Science, Bratislava, Slovak Republic, BMC SAV, Dúbravská Cesta 9, Bratislava 84505, Slovak Republic.
| | - Katarína Vigašová
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Centre of Slovak Academy of Science, Bratislava, Slovak Republic, BMC SAV, Dúbravská Cesta 9, Bratislava 84505, Slovak Republic.
| | - Sachin Gulati
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Centre of Slovak Academy of Science, Bratislava, Slovak Republic, BMC SAV, Dúbravská Cesta 9, Bratislava 84505, Slovak Republic.
| | - Matúš Durdík
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Centre of Slovak Academy of Science, Bratislava, Slovak Republic, BMC SAV, Dúbravská Cesta 9, Bratislava 84505, Slovak Republic.
| | - Pavol Košík
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Centre of Slovak Academy of Science, Bratislava, Slovak Republic, BMC SAV, Dúbravská Cesta 9, Bratislava 84505, Slovak Republic.
| | - Eva Marková
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Centre of Slovak Academy of Science, Bratislava, Slovak Republic, BMC SAV, Dúbravská Cesta 9, Bratislava 84505, Slovak Republic.
| | - Lukáš Jakl
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Centre of Slovak Academy of Science, Bratislava, Slovak Republic, BMC SAV, Dúbravská Cesta 9, Bratislava 84505, Slovak Republic.
| | - Lucián Zastko
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Centre of Slovak Academy of Science, Bratislava, Slovak Republic, BMC SAV, Dúbravská Cesta 9, Bratislava 84505, Slovak Republic; Department of Laboratory Medicine, Faculty of Health Sciences, Catholic University in Ruzomberok, Ružomberok, Slovak Republic, KUR, Nám. A. Hlinku 48, Ružomberok 03401, Slovak Republic.
| | - Kristína Kontrišová
- Department of Radiation Oncology, St. Elisabeth Cancer Institute, Bratislava, Slovak Republic, OUSA, Heydukova 48, Bratislava 81250, Slovak Republic.
| | - Igor Belyaev
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Centre of Slovak Academy of Science, Bratislava, Slovak Republic, BMC SAV, Dúbravská Cesta 9, Bratislava 84505, Slovak Republic.
| |
Collapse
|
3
|
Endesfelder D, Bucher M, Ainsbury EA, Oestreicher U. Influence of statistical methods on lower limits of dose estimation in biological dosimetry. Int J Radiat Biol 2024; 101:107-117. [PMID: 39680794 DOI: 10.1080/09553002.2024.2440870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Revised: 11/25/2024] [Accepted: 11/27/2024] [Indexed: 12/18/2024]
Abstract
PURPOSE In cases of radiological or nuclear events, biological dosimetry enables decisions whether an individual was exposed to ionizing radiation and the estimation of the dose. Several statistical methods are used to assess uncertainties. The stringency of the applied method has an impact on the lowest dose that can be detected. To obtain reliable and comparable results, it is crucial to harmonize the applied statistical methods. MATERIALS AND METHODS The decision threshold and detection limit of the statistical methods were derived for variable cell numbers. The coverage of the 95% confidence intervals as well as the false-positive and false-negative rates of the methods were compared based on simulations. The evaluated methods included a graphical method, the propagation of errors and a Bayesian method. RESULTS The minimum resolvable doses, the doses at the detection limit and the coverage were relatively variable between the compared methods. The Bayesian method showed the best coverage, lowest resolvable doses and had false-positive rates close to 5%. The graphical method with the combination of two 83% confidence intervals also showed promising results. The other methods were either too conservative or underestimated the uncertainties for some doses or cell numbers. CONCLUSIONS The assessment of the lower dose limits is a central part of biological dosimetry and the applied statistical methods have a strong influence on the interpretation of the results. Simulations enable comparisons between methods and provide important information for the harmonization and standardization of the uncertainty assessment.
Collapse
Affiliation(s)
- David Endesfelder
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection, Neuherberg, Germany
| | - Martin Bucher
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection, Neuherberg, Germany
| | - Elizabeth A Ainsbury
- Radiation Effects Department, UK Health Security Agency, Radiation, Chemicals and Environmental Hazards Directorate, Chilton, Oxfordshire, UK
| | - Ursula Oestreicher
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection, Neuherberg, Germany
| |
Collapse
|
4
|
Jang S, Lee J, Kim SH, Han S, Shin SG, Lee S, Kang I, Jo WS, Jeong S, Oh SJ, Lee CG. Radiation dose estimation with multiple artificial neural networks in dicentric chromosome assay. Int J Radiat Biol 2024; 100:865-874. [PMID: 38687685 DOI: 10.1080/09553002.2024.2338531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Accepted: 03/26/2024] [Indexed: 05/02/2024]
Abstract
PURPOSE The dicentric chromosome assay (DCA), often referred to as the 'gold standard' in radiation dose estimation, exhibits significant challenges as a consequence of its labor-intensive nature and dependency on expert knowledge. Existing automated technologies face limitations in accurately identifying dicentric chromosomes (DCs), resulting in decreased precision for radiation dose estimation. Furthermore, in the process of identifying DCs through automatic or semi-automatic methods, the resulting distribution could demonstrate under-dispersion or over-dispersion, which results in significant deviations from the Poisson distribution. In response to these issues, we developed an algorithm that employs deep learning to automatically identify chromosomes and perform fully automatic and accurate estimation of diverse radiation doses, adhering to a Poisson distribution. MATERIALS AND METHODS The dataset utilized for the dose estimation algorithm was generated from 30 healthy donors, with samples created across seven doses, ranging from 0 to 4 Gy. The procedure encompasses several steps: extracting images for dose estimation, counting chromosomes, and detecting DC and fragments. To accomplish these tasks, we utilize a diverse array of artificial neural networks (ANNs). The identification of DCs was accomplished using a detection mechanism that integrates both deep learning-based object detection and classification methods. Based on these detection results, dose-response curves were constructed. A dose estimation was carried out by combining a regression-based ANN with the Monte-Carlo method. RESULTS In the process of extracting images for dose analysis and identifying DCs, an under-dispersion tendency was observed. To rectify the discrepancy, classification ANN was employed to identify the results of DC detection. This approach led to satisfaction of Poisson distribution criteria by 32 out of the initial pool of 35 data points. In the subsequent stage, dose-response curves were constructed using data from 25 donors. Data provided by the remaining five donors served in performing dose estimations, which were subsequently calibrated by incorporating a regression-based ANN. Of the 23 points, 22 fell within their respective confidence intervals at p < .05 (95%), except for those associated with doses at levels below 0.5 Gy, where accurate calculation was obstructed by numerical issues. The accuracy of dose estimation has been improved for all radiation levels, with the exception of 1 Gy. CONCLUSIONS This study successfully demonstrates a high-precision dose estimation method across a general range up to 4 Gy through fully automated detection of DCs, adhering strictly to Poisson distribution. Incorporating multiple ANNs confirms the ability to perform fully automated radiation dose estimation. This approach is particularly advantageous in scenarios such as large-scale radiological incidents, improving operational efficiency and speeding up procedures while maintaining consistency in assessments. Moreover, it reduces potential human error and enhances the reliability of results.
Collapse
Affiliation(s)
- Seungsoo Jang
- Department of Advanced Nuclear Engineering, POSTECH, Pohang, Korea
| | - Janghee Lee
- Department of Advanced Nuclear Engineering, POSTECH, Pohang, Korea
| | | | | | | | | | | | - Wol Soon Jo
- Research Center, Dongnam Institute of Radiological and Medical Science, Busan, Korea
| | - Sookyung Jeong
- Research Center, Dongnam Institute of Radiological and Medical Science, Busan, Korea
| | - Su Jung Oh
- Research Center, Dongnam Institute of Radiological and Medical Science, Busan, Korea
| | - Chang Geun Lee
- Research Center, Dongnam Institute of Radiological and Medical Science, Busan, Korea
| |
Collapse
|
5
|
Lee YH, Yoon HJ, Yang SS, Lee IK, Jo WS, Jeong SK, Oh SJ, Kim J, Lee Y, Seong KM. Lessons on harmonization of scoring criteria for dicentric chromosome assay in South Korea. Int J Radiat Biol 2024; 100:709-714. [PMID: 38394348 DOI: 10.1080/09553002.2024.2316603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Accepted: 01/23/2024] [Indexed: 02/25/2024]
Abstract
PURPOSE Networking with other biodosimetry laboratories is necessary to assess the radiation exposure of many individuals in large-scale radiological accidents. The Korea biodosimetry network, K-BioDos, prepared harmonized scoring guidelines for dicentric chromosome assay to obtain homogeneous results within the network and investigated the efficiency of the guidelines. MATERIALS AND METHODS Three laboratories in K-BioDos harmonized the scoring guidelines for dicentric chromosome assay. The results of scoring dicentric chromosomes using the harmonized scoring guidelines were compared with the laboratories' results using their own methods. Feedback was collected from the scorers following the three intercomparison exercises in 3 consecutive years. RESULTS K-BioDos members showed comparable capacity to score dicentrics in the three exercises. However, the results of the K-BioDos guidelines showed no significant improvement over those of the scorers' own methods. According to the scorers, our harmonized guidelines led to more rejected metaphases and ultimately decreased the number of scorable metaphases compared with their own methods. Moreover, the scoring time was sometimes longer with the K-BioDos protocol because some scorers were not yet familiar with the guidelines, though most scorers reported that the time decreased or was unchanged. These challenges may cause low adherence to the guidelines. Most scorers expressed willingness to use the guidelines to select scorable metaphases or identify dicentrics for other biodosimetry works, whereas one did not want to use it due to the difference from their calibration curves. CONCLUSIONS We identified potential resistance to following the harmonized guidelines and received requests for more detailed methods. Our findings suggest that the harmonized criteria should be continually updated, and education and training should be provided for all scorers. These changes could allow members within the biodosimetry network to successfully collaborate and support each other in large-scale radiological accidents.
Collapse
Affiliation(s)
- Yang Hee Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center (NREMC), Korea Institute of Radiological & Medical Sciences (KIRAMS), Seoul, Republic of Korea
| | - Hyo Jin Yoon
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center (NREMC), Korea Institute of Radiological & Medical Sciences (KIRAMS), Seoul, Republic of Korea
| | - Su San Yang
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center (NREMC), Korea Institute of Radiological & Medical Sciences (KIRAMS), Seoul, Republic of Korea
| | - In Kyung Lee
- Korea Hydro & Nuclear Power Co, Radiation Health Institute, Seoul, Republic of Korea
| | - Wol Soon Jo
- Research Center, Dong Nam Institute of Radiological and Medical Sciences (DIRAMS), Busan, Republic of Korea
| | - Soo Kyung Jeong
- Research Center, Dong Nam Institute of Radiological and Medical Sciences (DIRAMS), Busan, Republic of Korea
| | - Su Jung Oh
- Research Center, Dong Nam Institute of Radiological and Medical Sciences (DIRAMS), Busan, Republic of Korea
| | - Jiin Kim
- Department of Medical Sciences, Graduate School, Soonchunhyang University, Asan, Republic of Korea
| | - Younghyun Lee
- Department of Medical Sciences, Graduate School, Soonchunhyang University, Asan, Republic of Korea
- Department of Biomedical Laboratory Science, College of Medical Sciences, Soonchunhyang University, Asan, Republic of Korea
| | - Ki Moon Seong
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center (NREMC), Korea Institute of Radiological & Medical Sciences (KIRAMS), Seoul, Republic of Korea
| |
Collapse
|
6
|
Wilkins RC, Beaton-Green LA. Development of high-throughput systems for biodosimetry. RADIATION PROTECTION DOSIMETRY 2023; 199:1477-1484. [PMID: 37721060 PMCID: PMC10720693 DOI: 10.1093/rpd/ncad060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 01/24/2023] [Accepted: 02/08/2023] [Indexed: 09/19/2023]
Abstract
Biomarkers for ionising radiation exposure have great utility in scenarios where there has been a potential exposure and physical dosimetry is missing or in dispute, such as for occupational and accidental exposures. Biomarkers that respond as a function of dose are particularly useful as biodosemeters to determine the dose of radiation to which an individual has been exposed. These dose measurements can also be used in medical scenarios to track doses from medical exposures and even have the potential to identify an individual's response to radiation exposure that could help tailor treatments. The measurement of biomarkers of exposure in medicine and for accidents, where a larger number of samples would be required, is limited by the throughput of analysis (i.e. the number of samples that could be processed and analysed), particularly for microscope-based methods, which tend to be labour-intensive. Rapid analysis in an emergency scenario, such as a large-scale accident, would provide dose estimates to medical practitioners, allowing timely administration of the appropriate medical countermeasures to help mitigate the effects of radiation exposure. In order to improve sample throughput for biomarker analysis, much effort has been devoted to automating the process from sample preparation through automated image analysis. This paper will focus mainly on biological endpoints traditionally analysed by microscopy, specifically dicentric chromosomes, micronuclei and gamma-H2AX. These endpoints provide examples where sample throughput has been improved through automated image acquisition, analysis of images acquired by microscopy, as well as methods that have been developed for analysis using imaging flow cytometry.
Collapse
Affiliation(s)
- Ruth C Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa K1A 1C1, Canada
| | - Lindsay A Beaton-Green
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa K1A 1C1, Canada
| |
Collapse
|
7
|
Meher PK, Lundholm L, Wojcik A. Fluorescence in situ hybridisation for interphase chromosomal aberration-based biological dosimetry. RADIATION PROTECTION DOSIMETRY 2023; 199:1501-1507. [PMID: 37721087 PMCID: PMC10505941 DOI: 10.1093/rpd/ncac264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 09/30/2022] [Accepted: 11/16/2022] [Indexed: 09/19/2023]
Abstract
Metaphase spreads stained with Giemsa or painted with chromosome-specific probes by fluorescence in situ hybridisation (FISH) have been in use since long for retrospective dose assessment (biological dosimetry). However, in cases of accidental exposure to ionising radiation, the culturing of lymphocytes to obtain metaphase chromosomes and analysis of chromosomal aberrations is time-consuming and problematic after high radiation doses. Similarly, analysing chromosomal damage in G0/G1 cells or nondividing cells by premature chromosome condensation is laborious. Following large-scale radiological emergencies, the time required for analysis is more important than precision of dose estimate. Painting of whole chromosomes using chromosome-specific probes in interphase nuclei by the FISH technique will eliminate the time required for cell culture and allow a fast dose estimate, provided that a meaningful dose-response can be obtained by scoring the number of chromosomal domains visible in interphase nuclei. In order to test the applicability of interphase FISH for quick biological dosimetry, whole blood from a healthy donor was irradiated with 8 Gy of gamma radiation. Irradiated whole blood was kept for 2 h at 37°C to allow DNA repair and thereafter processed for FISH with probes specific for Chromosomes-1 and 2. Damaged chromosomal fragments, distinguished by extra color domains, were observed in interphase nuclei of lymphocytes irradiated with 8 Gy. These fragments were efficiently detected and quantified by the FISH technique utilising both confocal and single plane fluorescence microscopy. Furthermore, a clear dose-response curve for interphase fragments was achieved following exposure to 0, 1, 2, 4 and 8 Gy of gamma radiation. These results demonstrate interphase FISH as a promising test for biodosimetry and for studying cytogenetic effects of radiation in nondividing cells.
Collapse
Affiliation(s)
- Prabodha Kumar Meher
- Centre for Radiation Protection Research, Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden
| | - Lovisa Lundholm
- Centre for Radiation Protection Research, Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden
| | - Andrzej Wojcik
- Centre for Radiation Protection Research, Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden
- Institute of Biology, Jan Kochanowski University, Kielce, Poland
| |
Collapse
|
8
|
Port M, Barquinero JF, Endesfelder D, Moquet J, Oestreicher U, Terzoudi G, Trompier F, Vral A, Abe Y, Ainsbury L, Alkebsi L, Amundson S, Badie C, Baeyens A, Balajee A, Balázs K, Barnard S, Bassinet C, Beaton-Green L, Beinke C, Bobyk L, Brochard P, Brzoska K, Bucher M, Ciesielski B, Cuceu C, Discher M, D,Oca M, Domínguez I, Doucha-Senf S, Dumitrescu A, Duy P, Finot F, Garty G, Ghandhi S, Gregoire E, Goh V, Güçlü I, Hadjiiska L, Hargitai R, Hristova R, Ishii K, Kis E, Juniewicz M, Kriehuber R, Lacombe J, Lee Y, Lopez Riego M, Lumniczky K, Mai T, Maltar-Strmečki N, Marrale M, Martinez J, Marciniak A, Maznyk N, McKeever S, Meher P, Milanova M, Miura T, Gil OM, Montoro A, Domene MM, Mrozik A, Nakayama R, O’Brien G, Oskamp D, Ostheim P, Pajic J, Pastor N, Patrono C, Pujol-Canadell M, Rodriguez MP, Repin M, Romanyukha A, Rößler U, Sabatier L, Sakai A, Scherthan H, Schüle S, Seong K, Sevriukova O, Sholom S, Sommer S, Suto Y, Sypko T, Szatmári T, Takahashi-Sugai M, Takebayashi K, Testa A, Testard I, Tichy A, Triantopoulou S, Tsuyama N, Unverricht-Yeboah M, Valente M, Van Hoey O, Wilkins R, Wojcik A, Wojewodzka M, Younghyun L, et alPort M, Barquinero JF, Endesfelder D, Moquet J, Oestreicher U, Terzoudi G, Trompier F, Vral A, Abe Y, Ainsbury L, Alkebsi L, Amundson S, Badie C, Baeyens A, Balajee A, Balázs K, Barnard S, Bassinet C, Beaton-Green L, Beinke C, Bobyk L, Brochard P, Brzoska K, Bucher M, Ciesielski B, Cuceu C, Discher M, D,Oca M, Domínguez I, Doucha-Senf S, Dumitrescu A, Duy P, Finot F, Garty G, Ghandhi S, Gregoire E, Goh V, Güçlü I, Hadjiiska L, Hargitai R, Hristova R, Ishii K, Kis E, Juniewicz M, Kriehuber R, Lacombe J, Lee Y, Lopez Riego M, Lumniczky K, Mai T, Maltar-Strmečki N, Marrale M, Martinez J, Marciniak A, Maznyk N, McKeever S, Meher P, Milanova M, Miura T, Gil OM, Montoro A, Domene MM, Mrozik A, Nakayama R, O’Brien G, Oskamp D, Ostheim P, Pajic J, Pastor N, Patrono C, Pujol-Canadell M, Rodriguez MP, Repin M, Romanyukha A, Rößler U, Sabatier L, Sakai A, Scherthan H, Schüle S, Seong K, Sevriukova O, Sholom S, Sommer S, Suto Y, Sypko T, Szatmári T, Takahashi-Sugai M, Takebayashi K, Testa A, Testard I, Tichy A, Triantopoulou S, Tsuyama N, Unverricht-Yeboah M, Valente M, Van Hoey O, Wilkins R, Wojcik A, Wojewodzka M, Younghyun L, Zafiropoulos D, Abend M. RENEB Inter-Laboratory Comparison 2021: Inter-Assay Comparison of Eight Dosimetry Assays. Radiat Res 2023; 199:535-555. [PMID: 37310880 PMCID: PMC10508307 DOI: 10.1667/rade-22-00207.1] [Show More Authors] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 01/10/2023] [Indexed: 06/15/2023]
Abstract
Tools for radiation exposure reconstruction are required to support the medical management of radiation victims in radiological or nuclear incidents. Different biological and physical dosimetry assays can be used for various exposure scenarios to estimate the dose of ionizing radiation a person has absorbed. Regular validation of the techniques through inter-laboratory comparisons (ILC) is essential to guarantee high quality results. In the current RENEB inter-laboratory comparison, the performance quality of established cytogenetic assays [dicentric chromosome assay (DCA), cytokinesis-block micronucleus assay (CBMN), stable chromosomal translocation assay (FISH) and premature chromosome condensation assay (PCC)] was tested in comparison to molecular biological assays [gamma-H2AX foci (gH2AX), gene expression (GE)] and physical dosimetry-based assays [electron paramagnetic resonance (EPR), optically or thermally stimulated luminescence (LUM)]. Three blinded coded samples (e.g., blood, enamel or mobiles) were exposed to 0, 1.2 or 3.5 Gy X-ray reference doses (240 kVp, 1 Gy/min). These doses roughly correspond to clinically relevant groups of unexposed to low exposed (0-1 Gy), moderately exposed (1-2 Gy, no severe acute health effects expected) and highly exposed individuals (>2 Gy, requiring early intensive medical care). In the frame of the current RENEB inter-laboratory comparison, samples were sent to 86 specialized teams in 46 organizations from 27 nations for dose estimation and identification of three clinically relevant groups. The time for sending early crude reports and more precise reports was documented for each laboratory and assay where possible. The quality of dose estimates was analyzed with three different levels of granularity, 1. by calculating the frequency of correctly reported clinically relevant dose categories, 2. by determining the number of dose estimates within the uncertainty intervals recommended for triage dosimetry (±0.5 Gy or ±1.0 Gy for doses <2.5 Gy or >2.5 Gy), and 3. by calculating the absolute difference (AD) of estimated doses relative to the reference doses. In total, 554 dose estimates were submitted within the 6-week period given before the exercise was closed. For samples processed with the highest priority, earliest dose estimates/categories were reported within 5-10 h of receipt for GE, gH2AX, LUM, EPR, 2-3 days for DCA, CBMN and within 6-7 days for the FISH assay. For the unirradiated control sample, the categorization in the correct clinically relevant group (0-1 Gy) as well as the allocation to the triage uncertainty interval was, with the exception of a few outliers, successfully performed for all assays. For the 3.5 Gy sample the percentage of correct classifications to the clinically relevant group (≥2 Gy) was between 89-100% for all assays, with the exception of gH2AX. For the 1.2 Gy sample, an exact allocation to the clinically relevant group was more difficult and 0-50% or 0-48% of the estimates were wrongly classified into the lowest or highest dose categories, respectively. For the irradiated samples, the correct allocation to the triage uncertainty intervals varied considerably between assays for the 1.2 Gy (29-76%) and 3.5 Gy (17-100%) samples. While a systematic shift towards higher doses was observed for the cytogenetic-based assays, extreme outliers exceeding the reference doses 2-6 fold were observed for EPR, FISH and GE assays. These outliers were related to a particular material examined (tooth enamel for EPR assay, reported as kerma in enamel, but when converted into the proper quantity, i.e. to kerma in air, expected dose estimates could be recalculated in most cases), the level of experience of the teams (FISH) and methodological uncertainties (GE). This was the first RENEB ILC where everything, from blood sampling to irradiation and shipment of the samples, was organized and realized at the same institution, for several biological and physical retrospective dosimetry assays. Almost all assays appeared comparably applicable for the identification of unexposed and highly exposed individuals and the allocation of medical relevant groups, with the latter requiring medical support for the acute radiation scenario simulated in this exercise. However, extreme outliers or a systematic shift of dose estimates have been observed for some assays. Possible reasons will be discussed in the assay specific papers of this special issue. In summary, this ILC clearly demonstrates the need to conduct regular exercises to identify research needs, but also to identify technical problems and to optimize the design of future ILCs.
Collapse
Affiliation(s)
- M. Port
- Bundeswehr Institute of Radiobiology, Munich, Germany
| | | | | | - J. Moquet
- UK Health Security Agency, Radiation, Chemical and Environmental Hazards Division, Oxfordshire, United Kingdom
| | | | - G. Terzoudi
- National Centre for Scientific Research “Demokritos”, Health Physics, Radiobiology & Cytogenetics Laboratory, Agia Paraskevi, Greece
| | - F. Trompier
- Institut de Radioprotection et de Surete Nucleaire, Fontenay aux Roses, France
| | - A. Vral
- Ghent University, Radiobiology Research Unit, Gent, Belgium
| | - Y. Abe
- Department of Radiation Biology and Protection, Nagasaki University, Japan
| | - L. Ainsbury
- UK Health Security Agency and Office for Health Improvement and Disparities, Cytogenetics and Pathology Group, Oxfordshire, England
| | - L Alkebsi
- Department of Radiation Measurement and Dose Assessment, National Institute of Radiological Sciences, National Institutes for Quantum Science and Technology, Chiba, Japan
| | - S.A. Amundson
- Columbia University, Irving Medical Center, Center for Radiological Research, New York, New York
| | - C. Badie
- UK Health Security Agency, Radiation, Chemical and Environmental Hazards Division, Oxfordshire, United Kingdom
| | - A. Baeyens
- Ghent University, Radiobiology Research Unit, Gent, Belgium
| | - A.S. Balajee
- Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge, Tennessee
| | - K. Balázs
- Radiation Medicine Unit, Department of Radiobiology and Radiohygiene, National Public Health Centre, Budapest, Hungary
| | - S. Barnard
- UK Health Security Agency, Radiation, Chemical and Environmental Hazards Division, Oxfordshire, United Kingdom
| | - C. Bassinet
- Institut de Radioprotection et de Surete Nucleaire, Fontenay aux Roses, France
| | | | - C. Beinke
- Bundeswehr Institute of Radiobiology, Munich, Germany
| | - L. Bobyk
- Institut de Recherche Biomédicale des Armées (IRBA), Bretigny Sur Orge, France
| | | | - K. Brzoska
- Institute of Nuclear Chemistry and Technology, Warsaw, Poland
| | - M. Bucher
- Bundesamt für Strahlenschutz, Oberschleißheim, Germany
| | - B. Ciesielski
- Medical University of Gdansk, Department of Physics and Biophysics, Gdansk, Poland
| | - C. Cuceu
- Genevolution, Porcheville, France
| | - M. Discher
- Paris-Lodron-University of Salzburg, Department of Environment and Biodiversity, 5020 Salzburg, Austria
| | - M.C. D,Oca
- Università Degli Studi di Palermo, Dipartimento di Fisica e Chimica “Emilio Segrè,” Palermo, Italy
| | - I. Domínguez
- Universidad de Sevilla, Departamento de Biología Celular, Sevilla, Spain
| | | | - A. Dumitrescu
- National Institute of Public Health, Radiation Hygiene Laboratory, Bucharest, Romania
| | - P.N. Duy
- Dalat Nuclear Research Institute, Radiation Technlogy & Biotechnology Center, Dalat City, Vietnam
| | - F. Finot
- Genevolution, Porcheville, France
| | - G. Garty
- Columbia University, Irving Medical Center, Center for Radiological Research, New York, New York
| | - S.A. Ghandhi
- Columbia University, Irving Medical Center, Center for Radiological Research, New York, New York
| | - E. Gregoire
- Institut de Radioprotection et de Surete Nucleaire, Fontenay aux Roses, France
| | - V.S.T. Goh
- Department of Radiobiology, Singapore Nuclear Research and Safety Initiative (SNRSI), National University of Singapore, Singapore
| | - I. Güçlü
- TENMAK, Nuclear Energy Research Institute, Technology Development and Nuclear Research Department, Türkey
| | - L. Hadjiiska
- National Centre of Radiobiology and Radiation Protection, Sofia, Bulgaria
| | - R. Hargitai
- Radiation Medicine Unit, Department of Radiobiology and Radiohygiene, National Public Health Centre, Budapest, Hungary
| | - R. Hristova
- National Centre of Radiobiology and Radiation Protection, Sofia, Bulgaria
| | - K. Ishii
- Department of Radiation Measurement and Dose Assessment, National Institute of Radiological Sciences, National Institutes for Quantum Science and Technology, Chiba, Japan
| | - E. Kis
- Radiation Medicine Unit, Department of Radiobiology and Radiohygiene, National Public Health Centre, Budapest, Hungary
| | - M. Juniewicz
- Medical University of Gdansk, Department of Physics and Biophysics, Gdansk, Poland
| | - R. Kriehuber
- Department of Safety and Radiation Protection, Forschungszentrum Jülich, Jülich, Germany
| | - J. Lacombe
- University of Arizona, Center for Applied Nanobioscience & Medicine, Phoenix, Arizona
| | - Y. Lee
- Laboratory of Biological Dosimetry, Korea Institute of Radiological & Medical Sciences, Seoul, Republic of Korea
| | | | - K. Lumniczky
- Radiation Medicine Unit, Department of Radiobiology and Radiohygiene, National Public Health Centre, Budapest, Hungary
| | - T.T. Mai
- Dalat Nuclear Research Institute, Radiation Technlogy & Biotechnology Center, Dalat City, Vietnam
| | - N. Maltar-Strmečki
- Ruðer Boškovic Institute, Division of Physical Chemistry, Zagreb, Croatia
| | - M. Marrale
- Università Degli Studi di Palermo, Dipartimento di Fisica e Chimica “Emilio Segrè,” Palermo, Italy
| | - J.S. Martinez
- Institut de Radioprotection et de Surete Nucleaire, Fontenay aux Roses, France
| | - A. Marciniak
- Medical University of Gdansk, Department of Physics and Biophysics, Gdansk, Poland
| | - N. Maznyk
- Radiation Cytogenetics Laboratory, S.P. Grigoriev Institute for Medical Radiology and Oncology of Ukrainian National Academy of Medical Science, Kharkiv, Ukraine
| | - S.W.S. McKeever
- Radiation Dosimetry Laboratory, Oklahoma State University, Stillwater, Oklahoma
| | | | - M. Milanova
- University of Defense, Faculty of Military Health Sciences, Hradec Králové, Czech Republic
| | - T. Miura
- Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Japan
| | - O. Monteiro Gil
- Instituto Superior Técnico/ Campus Tecnológico e Nuclear, Lisbon, Portugal
| | - A. Montoro
- Servicio de Protección Radiológica. Laboratorio de Dosimetría Biológica, Valencia, Spain
| | - M. Moreno Domene
- Hospital General Universitario Gregorio Marañón, Laboratorio de dosimetría biológica, Madrid, Spain
| | - A. Mrozik
- Institute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland
| | - R. Nakayama
- Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Japan
| | - G. O’Brien
- UK Health Security Agency, Radiation, Chemical and Environmental Hazards Division, Oxfordshire, United Kingdom
| | - D. Oskamp
- Department of Safety and Radiation Protection, Forschungszentrum Jülich, Jülich, Germany
| | - P. Ostheim
- Bundeswehr Institute of Radiobiology, Munich, Germany
| | - J. Pajic
- Serbian Institute of Occupational Health, Belgrade, Serbia
| | - N. Pastor
- Universidad de Sevilla, Departamento de Biología Celular, Sevilla, Spain
| | - C. Patrono
- Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Rome, Italy
| | | | - M.J. Prieto Rodriguez
- Hospital General Universitario Gregorio Marañón, Laboratorio de dosimetría biológica, Madrid, Spain
| | - M. Repin
- Columbia University, Irving Medical Center, Center for Radiological Research, New York, New York
| | | | - U. Rößler
- Bundesamt für Strahlenschutz, Oberschleißheim, Germany
| | | | - A. Sakai
- Department of Radiation Life Sciences, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - H. Scherthan
- Bundeswehr Institute of Radiobiology, Munich, Germany
| | - S. Schüle
- Bundeswehr Institute of Radiobiology, Munich, Germany
| | - K.M. Seong
- Laboratory of Biological Dosimetry, Korea Institute of Radiological & Medical Sciences, Seoul, Republic of Korea
| | | | - S. Sholom
- Radiation Dosimetry Laboratory, Oklahoma State University, Stillwater, Oklahoma
| | - S. Sommer
- Institute of Nuclear Chemistry and Technology, Warsaw, Poland
| | - Y. Suto
- Department of Radiation Measurement and Dose Assessment, National Institute of Radiological Sciences, National Institutes for Quantum Science and Technology, Chiba, Japan
| | - T. Sypko
- Radiation Cytogenetics Laboratory, S.P. Grigoriev Institute for Medical Radiology and Oncology of Ukrainian National Academy of Medical Science, Kharkiv, Ukraine
| | - T. Szatmári
- Radiation Medicine Unit, Department of Radiobiology and Radiohygiene, National Public Health Centre, Budapest, Hungary
| | - M. Takahashi-Sugai
- Department of Radiation Life Sciences, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - K. Takebayashi
- Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Japan
| | - A. Testa
- Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Rome, Italy
| | - I. Testard
- CEA-Saclay, Gif-sur-Yvette Cedex, France
| | - A. Tichy
- University of Defense, Faculty of Military Health Sciences, Hradec Králové, Czech Republic
| | - S. Triantopoulou
- National Centre for Scientific Research “Demokritos”, Health Physics, Radiobiology & Cytogenetics Laboratory, Agia Paraskevi, Greece
| | - N. Tsuyama
- Department of Radiation Life Sciences, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - M. Unverricht-Yeboah
- Department of Safety and Radiation Protection, Forschungszentrum Jülich, Jülich, Germany
| | - M. Valente
- CEA-Saclay, Gif-sur-Yvette Cedex, France
| | - O. Van Hoey
- Belgian Nuclear Research Center SCK CEN, Mol, Belgium
| | | | - A. Wojcik
- Stockholm University, Stockholm, Sweden
| | - M. Wojewodzka
- Institute of Nuclear Chemistry and Technology, Warsaw, Poland
| | - Lee Younghyun
- Laboratory of Biological Dosimetry, Korea Institute of Radiological & Medical Sciences, Seoul, Republic of Korea
| | - D. Zafiropoulos
- Laboratori Nazionali di Legnaro - Istituto Nazionale di Fisica Nucleare, Legnaro, Italy
| | - M. Abend
- Bundeswehr Institute of Radiobiology, Munich, Germany
| |
Collapse
|
9
|
Kao EF, Hsieh YJ, Ke CC, Lin WC, Ou Yang FY. Automated identification of single and clustered chromosomes for metaphase image analysis. Heliyon 2023; 9:e16408. [PMID: 37251870 PMCID: PMC10220244 DOI: 10.1016/j.heliyon.2023.e16408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 05/12/2023] [Accepted: 05/16/2023] [Indexed: 05/31/2023] Open
Abstract
Background Chromosome analysis is laborious and time-consuming. Automated methods can significantly increase the efficiency of chromosome analysis. For the automated analysis of chromosome images, single and clustered chromosomes must be identified. Herein, we propose a feature-based method for distinguishing between single chromosomes and clustered chromosome. Method The proposed method comprises three main steps. In the first step, chromosome objects are segmented from metaphase chromosome images in advance. In the second step, seven features are extracted from each segmented object, i.e., the normalized area, area/boundary ratio, side branch index, exhaustive thresholding index, normalized minimum width, minimum concave angle, and maximum boundary shift. Finally, the segmented objects are classified as a single chromosome or chromosome cluster using a combination of the seven features. Results In total, 43,391 segmented objects, including 39,892 single chromosomes and 3,499 chromosome clusters, are used to evaluate the proposed method. The results show that the proposed method achieves an accuracy of 98.92% by combining the seven features using support vector machine. Conclusions The proposed method is highly effective in distinguishing between single and clustered chromosomes and can be used as a preprocessing procedure for automated chromosome image analysis.
Collapse
Affiliation(s)
- E-Fong Kao
- Department of Medical Imaging and Radiological Sciences, College of Health Sciences, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Ya-Ju Hsieh
- Department of Medical Imaging and Radiological Sciences, College of Health Sciences, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chien-Chih Ke
- Department of Medical Imaging and Radiological Sciences, College of Health Sciences, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Wan-Chi Lin
- Isotope Application Division, Institute of Nuclear Energy Research, Taoyuan, Taiwan
| | - Fang-Yu Ou Yang
- Isotope Application Division, Institute of Nuclear Energy Research, Taoyuan, Taiwan
| |
Collapse
|
10
|
Choi YY, Kim A, Lee Y, Lee YH, Park M, Shin E, Park S, Youn B, Seong KM. The miR-126-5p and miR-212-3p in the extracellular vesicles activate monocytes in the early stage of radiation-induced vascular inflammation implicated in atherosclerosis. J Extracell Vesicles 2023; 12:e12325. [PMID: 37140946 PMCID: PMC10158827 DOI: 10.1002/jev2.12325] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 04/04/2023] [Accepted: 04/12/2023] [Indexed: 05/05/2023] Open
Abstract
People exposed to radiation in cancer therapy and nuclear accidents are at increased risk of cardiovascular outcomes in long-term survivors. Extracellular vesicles (EVs) are involved in radiation-induced endothelial dysfunction, but their role in the early stage of vascular inflammation after radiation exposure remains to be fully understood. Herein, we demonstrate that endothelial cell-derived EVs containing miRNAs initiate monocyte activation in radiation-induced vascular inflammation. In vitro co-culture and in vivo experimental data showed that endothelial EVs can be sensitively increased by radiation exposure in a dose-dependent manner, and stimulate monocytes releasing monocytic EVs and adhesion to endothelial cells together with an increase in the expression of genes encoding specific ligands for cell-cell interaction. Small RNA sequencing and transfection using mimics and inhibitors explained that miR-126-5p and miR-212-3p enriched in endothelial EVs initiate vascular inflammation by monocyte activation after radiation exposure. Moreover, miR-126-5p could be detected in the circulating endothelial EVs of radiation-induced atherosclerosis model mice, which was found to be tightly correlated with the atherogenic index of plasma. In summary, our study showed that miR-126-5p and miR-212-3p present in the endothelial EVs mediate the inflammatory signals to activate monocytes in radiation-induced vascular injury. A better understanding of the circulating endothelial EVs content can promote their use as diagnostic and prognostic biomarkers for atherosclerosis after radiation exposure.
Collapse
Affiliation(s)
- You Yeon Choi
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - Areumnuri Kim
- Laboratory of Radiation Exposure and Therapeutics, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - Younghyun Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - Yang Hee Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - Mineon Park
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - Eunguk Shin
- Department of Biological Sciences, Pusan National University, Busan, Republic of Korea
| | - Sunhoo Park
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| | - BuHyun Youn
- Department of Biological Sciences, Pusan National University, Busan, Republic of Korea
| | - Ki Moon Seong
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, KIRAMS, Seoul, Republic of Korea
| |
Collapse
|
11
|
Endesfelder D, Kulka U, Bucher M, Giesen U, Garty G, Beinke C, Port M, Gruel G, Gregoire E, Terzoudi G, Triantopoulou S, Ainsbury EA, Moquet J, Sun M, Prieto MJ, Moreno Domene M, Barquinero JF, Pujol-Canadell M, Vral A, Baeyens A, Wojcik A, Oestreicher U. International Comparison Exercise for Biological Dosimetry after Exposures with Neutrons Performed at Two Irradiation Facilities as Part of the BALANCE Project. Cytogenet Genome Res 2023; 163:163-177. [PMID: 37071978 PMCID: PMC10641373 DOI: 10.1159/000530728] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Accepted: 04/10/2023] [Indexed: 04/20/2023] Open
Abstract
In the case of a radiological or nuclear event, biological dosimetry can be an important tool to support clinical decision-making. During a nuclear event, individuals might be exposed to a mixed field of neutrons and photons. The composition of the field and the neutron energy spectrum influence the degree of damage to the chromosomes. During the transatlantic BALANCE project, an exposure similar to a Hiroshima-like device at a distance of 1.5 km from the epicenter was simulated, and biological dosimetry based on dicentric chromosomes was performed to evaluate the participants ability to discover unknown doses and to test the influence of differences in neutron spectra. In a first step, calibration curves were established by irradiating blood samples with 5 doses in the range of 0-4 Gy at two different facilities in Germany (Physikalisch-Technische Bundesanstalt [PTB]) and the USA (the Columbia IND Neutron Facility [CINF]). The samples were sent to eight participating laboratories from the RENEB network and dicentric chromosomes were scored by each participant. Next, blood samples were irradiated with 4 blind doses in each of the two facilities and sent to the participants to provide dose estimates based on the established calibration curves. Manual and semiautomatic scoring of dicentric chromosomes were evaluated for their applicability to neutron exposures. Moreover, the biological effectiveness of the neutrons from the two irradiation facilities was compared. The calibration curves from samples irradiated at CINF showed a 1.4 times higher biological effectiveness compared to samples irradiated at PTB. For manual scoring of dicentric chromosomes, the doses of the test samples were mostly successfully resolved based on the calibration curves established during the project. For semiautomatic scoring, the dose estimation for the test samples was less successful. Doses >2 Gy in the calibration curves revealed nonlinear associations between dose and dispersion index of the dicentric counts, especially for manual scoring. The differences in the biological effectiveness between the irradiation facilities suggested that the neutron energy spectrum can have a strong impact on the dicentric counts.
Collapse
Affiliation(s)
- David Endesfelder
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany,
| | - Ulrike Kulka
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Martin Bucher
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Ulrich Giesen
- Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Germany
| | - Guy Garty
- Radiological Research Accelerator Facility (RARAF), Columbia University, Irvington, New York, USA
| | | | - Matthias Port
- Bundeswehr Institute of Radiobiology, Munich, Germany
| | - Gaetan Gruel
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSE-Santé, SERAMED, LRAcc, Fontenay-aux-Roses, France
| | - Eric Gregoire
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PSE-Santé, SERAMED, LRAcc, Fontenay-aux-Roses, France
| | - Georgia Terzoudi
- Health Physics, Radiobiology & Cytogenetics Laboratory, National Centre for Scientific Research "Demokritos,", Athens, Greece
| | - Sotiria Triantopoulou
- Health Physics, Radiobiology & Cytogenetics Laboratory, National Centre for Scientific Research "Demokritos,", Athens, Greece
| | - Elizabeth A Ainsbury
- Radiation, Chemicals and Environmental Hazards Directorate, UK Health Security Agency, Chilton, Oxfordshire, UK
| | - Jayne Moquet
- Radiation, Chemicals and Environmental Hazards Directorate, UK Health Security Agency, Chilton, Oxfordshire, UK
| | - Mingzhu Sun
- Radiation, Chemicals and Environmental Hazards Directorate, UK Health Security Agency, Chilton, Oxfordshire, UK
| | - María Jesús Prieto
- Centro de Oncología Radioterápica, Laboratorio de Dosimetría Biológica, Hospital General Universitario Gregorio Marañón, Madrid, Spain
| | - Mercedes Moreno Domene
- Centro de Oncología Radioterápica, Laboratorio de Dosimetría Biológica, Hospital General Universitario Gregorio Marañón, Madrid, Spain
| | - Joan-Francesc Barquinero
- Departament de Biologia Animal, Unitat d'Antropologia Biològica, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Monica Pujol-Canadell
- Departament de Biologia Animal, Unitat d'Antropologia Biològica, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Anne Vral
- Faculty of Medicine and Health Sciences, Department of Human Structure and Repair, Radiobiology Research Unit, Ghent University, Gent, Belgium
| | - Ans Baeyens
- Faculty of Medicine and Health Sciences, Department of Human Structure and Repair, Radiobiology Research Unit, Ghent University, Gent, Belgium
| | - Andrzej Wojcik
- Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden
- Institute of Biology, Jan Kochanowski University, Kielce, Poland
| | - Ursula Oestreicher
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| |
Collapse
|
12
|
M’Kacher R, Colicchio B, Junker S, El Maalouf E, Heidingsfelder L, Plesch A, Dieterlen A, Jeandidier E, Carde P, Voisin P. High Resolution and Automatable Cytogenetic Biodosimetry Using In Situ Telomere and Centromere Hybridization for the Accurate Detection of DNA Damage: An Overview. Int J Mol Sci 2023; 24:ijms24065699. [PMID: 36982772 PMCID: PMC10054499 DOI: 10.3390/ijms24065699] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 03/07/2023] [Accepted: 03/10/2023] [Indexed: 03/19/2023] Open
Abstract
In the event of a radiological or nuclear accident, or when physical dosimetry is not available, the scoring of radiation-induced chromosomal aberrations in lymphocytes constitutes an essential tool for the estimation of the absorbed dose of the exposed individual and for effective triage. Cytogenetic biodosimetry employs different cytogenetic assays including the scoring of dicentrics, micronuclei, and translocations as well as analyses of induced premature chromosome condensation to define the frequency of chromosome aberrations. However, inherent challenges using these techniques include the considerable time span from sampling to result, the sensitivity and specificity of the various techniques, and the requirement of highly skilled personnel. Thus, techniques that obviate these challenges are needed. The introduction of telomere and centromere (TC) staining have successfully met these challenges and, in addition, greatly improved the efficiency of cytogenetic biodosimetry through the development of automated approaches, thus reducing the need for specialized personnel. Here, we review the role of the various cytogenetic dosimeters and their recent improvements in the management of populations exposed to genotoxic agents such as ionizing radiation. Finally, we discuss the emerging potentials to exploit these techniques in a wider spectrum of medical and biological applications, e.g., in cancer biology to identify prognostic biomarkers for the optimal triage and treatment of patients.
Collapse
Affiliation(s)
- Radhia M’Kacher
- Cell Environment DNA Damage R&D, Genopole, 91000 Evry-Courcouronnes, France
- Correspondence: ; Tel.: +33-160878918
| | - Bruno Colicchio
- IRIMAS, Institut de Recherche en Informatique, Mathématiques, Automatique et Signal, Université de Haute-Alsace, 69093 Mulhouse, France
| | - Steffen Junker
- Institute of Biomedicine, University of Aarhus, DK-8000 Aarhus, Denmark
| | - Elie El Maalouf
- Cell Environment DNA Damage R&D, Genopole, 91000 Evry-Courcouronnes, France
| | | | - Andreas Plesch
- MetaSystems GmbH, Robert-Bosch-Str. 6, D-68804 Altlussheim, Germany
| | - Alain Dieterlen
- IRIMAS, Institut de Recherche en Informatique, Mathématiques, Automatique et Signal, Université de Haute-Alsace, 69093 Mulhouse, France
| | - Eric Jeandidier
- Laboratoire de Génétique, Groupe Hospitalier de la Région de Mulhouse Sud-Alsace, 69093 Mulhouse, France
| | - Patrice Carde
- Department of Hematology, Institut Gustave Roussy, 94804 Villejuif, France
| | - Philippe Voisin
- Cell Environment DNA Damage R&D, Genopole, 91000 Evry-Courcouronnes, France
| |
Collapse
|
13
|
Dicentric chromosome assay using a deep learning-based automated system. Sci Rep 2022; 12:22097. [PMID: 36543843 PMCID: PMC9772420 DOI: 10.1038/s41598-022-25856-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Accepted: 12/06/2022] [Indexed: 12/24/2022] Open
Abstract
The dicentric chromosome assay is the "gold standard" in biodosimetry for estimating radiation exposure. However, its large-scale deployment is limited owing to its time-consuming nature and requirement for expert reviewers. Therefore, a recently developed automated system was evaluated for the dicentric chromosome assay. A previously constructed deep learning-based automatic dose-estimation system (DLADES) was used to construct dose curves and calculate estimated doses. Blood samples from two donors were exposed to cobalt-60 gamma rays (0-4 Gy, 0.8 Gy/min). The DLADES efficiently identified monocentric and dicentric chromosomes but showed impaired recognition of complete cells with 46 chromosomes. We estimated the chromosome number of each "Accepted" sample in the DLADES and sorted similar-quality images by removing outliers using the 1.5IQR method. Eleven of the 12 data points followed Poisson distribution. Blind samples were prepared for each dose to verify the accuracy of the estimated dose generated by the curve. The estimated dose was calculated using Merkle's method. The actual dose for each sample was within the 95% confidence limits of the estimated dose. Sorting similar-quality images using chromosome numbers is crucial for the automated dicentric chromosome assay. We successfully constructed a dose-response curve and determined the estimated dose using the DLADES.
Collapse
|
14
|
Lee Y, Kim SH, Lee YH, Yang SS, Yoon HJ, Wilkins RC, Jang S. Application of a semi-automated dicentric scoring system in triage and monitoring occupational radiation exposure. Front Public Health 2022; 10:1002501. [PMID: 36339161 PMCID: PMC9631783 DOI: 10.3389/fpubh.2022.1002501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 10/06/2022] [Indexed: 01/27/2023] Open
Abstract
The dicentric chromosome assay (DCA) is considered the gold standard for radiation biodosimetry, but it is limited by its long dicentric scoring time and need for skilled scorers. The automation of scoring dicentrics has been considered a strategy to overcome the constraints of DCA. However, the studies on automated scoring methods are limited compared to those on conventional manual DCA. Our study aims to assess the performance of a semi-automated scoring method for DCA using ex vivo and in vivo irradiated samples. Dose estimations of 39 blind samples irradiated ex vivo and 35 industrial radiographers occupationally exposed in vivo were estimated using the manual and semi-automated scoring methods and subsequently compared. The semi-automated scoring method, which removed the false positives of automated scoring using the dicentric chromosome (DC) scoring algorithm, had an accuracy of 94.9% in the ex vivo irradiated samples. It also had more than 90% accuracy, sensitivity, and specificity to distinguish binary dose categories reflecting clinical, diagnostic, and epidemiological significance. These data were comparable to those of manual DCA. Moreover, Cohen's kappa statistic and McNemar's test showed a substantial agreement between the two methods for categorizing in vivo samples into never and ever radiation exposure. There was also a significant correlation between the two methods. Despite of comparable results with two methods, lower sensitivity of semi-automated scoring method could be limited to assess various radiation exposures. Taken together, our findings show the semi-automated scoring method can provide accurate dose estimation rapidly, and can be useful as an alternative to manual DCA for biodosimetry in large-scale accidents or cases to monitor radiation exposure of radiation workers.
Collapse
Affiliation(s)
- Younghyun Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea,Department of Biomedical Laboratory Science, College of Medical Sciences, Soonchunhyang University, Asan, South Korea
| | - Seung Hyun Kim
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Yang Hee Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Su San Yang
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Hyo Jin Yoon
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Ruth C. Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, ON, Canada
| | - Seongjae Jang
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea,*Correspondence: Seongjae Jang
| |
Collapse
|
15
|
Abdelhalim MA, Patel A, Moquet J, Saha P, Smith A, Badie C, Anderson R, Ainsbury E, Modarai B. Higher Incidence of Chromosomal Aberrations in Operators Performing a Large Volume of Endovascular Procedures. Circulation 2022; 145:1808-1810. [PMID: 35696458 DOI: 10.1161/circulationaha.121.058139] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Mohamed A Abdelhalim
- Academic Department of Vascular Surgery, School of Cardiovascular and Metabolic Medicine and Sciences, King's College London, British Heart Foundation Centre of Research Excellence and Guy's and St. Thomas' National Health Service Foundation Trust Biomedical Research Centre, United Kingdom (M.A.A., A.P., P.S., A.S., B.M.)
| | - Ashish Patel
- Academic Department of Vascular Surgery, School of Cardiovascular and Metabolic Medicine and Sciences, King's College London, British Heart Foundation Centre of Research Excellence and Guy's and St. Thomas' National Health Service Foundation Trust Biomedical Research Centre, United Kingdom (M.A.A., A.P., P.S., A.S., B.M.)
| | - Jayne Moquet
- United Kingdom Health Security Agency Centre for Radiation, Chemical and Environmental Threats and Hazards, Chilton, United Kingdom (J.M., C.B., E.A.)
| | - Prakash Saha
- Academic Department of Vascular Surgery, School of Cardiovascular and Metabolic Medicine and Sciences, King's College London, British Heart Foundation Centre of Research Excellence and Guy's and St. Thomas' National Health Service Foundation Trust Biomedical Research Centre, United Kingdom (M.A.A., A.P., P.S., A.S., B.M.)
| | - Alberto Smith
- Academic Department of Vascular Surgery, School of Cardiovascular and Metabolic Medicine and Sciences, King's College London, British Heart Foundation Centre of Research Excellence and Guy's and St. Thomas' National Health Service Foundation Trust Biomedical Research Centre, United Kingdom (M.A.A., A.P., P.S., A.S., B.M.)
| | - Christophe Badie
- United Kingdom Health Security Agency Centre for Radiation, Chemical and Environmental Threats and Hazards, Chilton, United Kingdom (J.M., C.B., E.A.)
| | - Rhona Anderson
- Centre for Health Effects of Radiological and Chemical Agents, College of Health, Medicine and Life Sciences, Brunel University London, United Kingdom (R.A.)
| | - Elizabeth Ainsbury
- United Kingdom Health Security Agency Centre for Radiation, Chemical and Environmental Threats and Hazards, Chilton, United Kingdom (J.M., C.B., E.A.)
| | - Bijan Modarai
- Academic Department of Vascular Surgery, School of Cardiovascular and Metabolic Medicine and Sciences, King's College London, British Heart Foundation Centre of Research Excellence and Guy's and St. Thomas' National Health Service Foundation Trust Biomedical Research Centre, United Kingdom (M.A.A., A.P., P.S., A.S., B.M.)
| |
Collapse
|
16
|
Bucher M, Weiss T, Endesfelder D, Trompier F, Ristic Y, Kunert P, Schlattl H, Giussani A, Oestreicher U. Dose Variations Using an X-Ray Cabinet to Establish in vitro Dose-Response Curves for Biological Dosimetry Assays. Front Public Health 2022; 10:903509. [PMID: 35655448 PMCID: PMC9152255 DOI: 10.3389/fpubh.2022.903509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 04/25/2022] [Indexed: 11/13/2022] Open
Abstract
In biological dosimetry, dose-response curves are essential for reliable retrospective dose estimation of individual exposure in case of a radiation accident. Therefore, blood samples are irradiated in vitro and evaluated based on the applied assay. Accurate physical dosimetry of the irradiation performance is a critical part of the experimental procedure and is influenced by the experimental setup, especially when X-ray cabinets are used. The aim of this study was to investigate variations and pitfalls associated with the experimental setups used to establish calibration curves in biological dosimetry with X-ray cabinets. In this study, irradiation was performed with an X-ray source (195 kV, 10 mA, 0.5 mm Cu filter, dose rate 0.52 Gy/min, 1st and 2nd half-value layer = 1.01 and 1.76 mm Cu, respectively, average energy 86.9 keV). Blood collection tubes were irradiated with a dose of 1 Gy in vertical or horizontal orientation in the center of the beam area with or without usage of an additional fan heater. To evaluate the influence of the setups, physical dose measurements using thermoluminescence dosimeters, electron paramagnetic resonance dosimetry and ionization chamber as well as biological effects, quantified by dicentric chromosomes and micronuclei, were compared. This study revealed that the orientation of the sample tubes (vertical vs. horizontal) had a significant effect on the radiation dose with a variation of -41% up to +49% and contributed to a dose gradient of up to 870 mGy inside the vertical tubes due to the size of the sample tubes and the associated differences in the distance to the focal point of the tube. The number of dicentric chromosomes and micronuclei differed by ~30% between both orientations. An additional fan heater had no consistent impact. Therefore, dosimetric monitoring of experimental irradiation setups is mandatory prior to the establishment of calibration curves in biological dosimetry. Careful consideration of the experimental setup in collaboration with physicists is required to ensure traceability and reproducibility of irradiation conditions, to correlate the radiation dose and the number of aberrations correctly and to avoid systematical bias influencing the dose estimation in the frame of biological dosimetry.
Collapse
Affiliation(s)
- Martin Bucher
- Department of Effects and Risks of Ionizing and Non-Ionizing Radiation, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Tina Weiss
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - David Endesfelder
- Department of Effects and Risks of Ionizing and Non-Ionizing Radiation, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Francois Trompier
- Department of External Dosimetry, Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
| | - Yoann Ristic
- Department of External Dosimetry, Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France
| | - Patrizia Kunert
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Helmut Schlattl
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Augusto Giussani
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| | - Ursula Oestreicher
- Department of Effects and Risks of Ionizing and Non-Ionizing Radiation, Federal Office for Radiation Protection (BfS), Oberschleißheim, Germany
| |
Collapse
|
17
|
Abstract
Biological dosimetry is an internationally recognized method for quantifying and estimating radiation dose following suspected or verified excessive exposure to ionising radiation. In severe radiation accidents where a large number of people are potentially affected, it is possible to distinguish irradiated from non-irradiated people in order to initiate appropriate medical care if necessary. In addition to severe incidents caused by technical failure, environmental disasters, military actions, or criminal abuse, there are also radiation accidents in which only one or a few individuals are affected in the frame of occupational or medical exposure. The requirements for biological dosimetry are fundamentally different for these two scenarios. In particular, for large-scale radiation accidents, pre-screening methods are necessary to increase the throughput of samples for a rough first-dose categorization. The rapid development and increasing use of omics methods in research as well as in individual applications provides new opportunities for biological dosimetry. In addition to the discovery and search for new biomarkers, dosimetry assays based on omics technologies are becoming increasingly interesting and hold great potential, especially for large-scale dosimetry. In the following review, the different areas of biological dosimetry, the problems in finding suitable biomarkers, the current status of biomarker research based on omics, the potential applications of assays using omics technologies, and also the limitations for the different areas of biological dosimetry are discussed.
Collapse
|
18
|
Vinnikov V, Belyakov O. Clinical Applications of Biological Dosimetry in Patients Exposed to Low Dose Radiation Due to Radiological, Imaging or Nuclear Medicine Procedures. Semin Nucl Med 2021; 52:114-139. [PMID: 34879905 DOI: 10.1053/j.semnuclmed.2021.11.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Radiation dosimetric biomarkers have found applications beyond radiation protection area and now are actively introduced into clinical practice. Cytogenetic assays appeared to be a valuable tool for individualized quantifying radiation effects in patients, with high capability for assessing genotoxicity of various medical exposure modalities and providing meaningful radiation dose estimates for prognoses of radiation-related cancer risk. This review summarized current data on the use of biological dosimetry methods in patients undergoing various medical irradiations to low doses. The highlighted topics include basic aspects of biological dosimetry and its limitations in the range of low radiation doses, and main patterns of in vivo induction of radiation biomarkers in clinical exposure scenarios, occurring in X-ray diagnostics, computed tomography, interventional radiology, low dose radiotherapy, and nuclear medicine (internally administered 131I and other radiopharmaceuticals). Additionally, several specific issues, examined by biodosimetry techniques, are analysed, such as contrast media effect, radiation response in pediatric patients, impact of magnetic resonance imaging, evaluation of radioprotectors, detection of patients' abnormal intrinsic radiosensitivity and dose estimation in persons involved in medical radiation incidents. A prognosis of possible directions for further improvements in this area includes the automation of cytogenetic analysis, introduction of molecular biodosimeters and development of multiparametric biodosimetry platforms. A potential approach to the advanced biodosimetry of internal exposure and/or low dose external irradiation is suggested; this can be a multiparametric platform based on the combination of the γ-H2AX foci, dicentric, and translocation assays, each applied in the optimum postexposure time range, with the amalgamation of the dose estimates. The study revealed the necessity of further research, which might clarify medical radiation safety concerns for patients via using stringent biodosimetry methodology.
Collapse
Affiliation(s)
- Volodymyr Vinnikov
- International Atomic Energy Agency (IAEA), Vienna, Austria; Grigoriev Institute for Medical Radiology and Oncology (GIMRO), Kharkiv, Ukraine.
| | - Oleg Belyakov
- International Atomic Energy Agency (IAEA), Vienna, Austria
| |
Collapse
|
19
|
López JS, Pujol-Canadell M, Puig P, Ribas M, Carrasco P, Armengol G, Barquinero JF. Establishment and validation of surface model for biodosimetry based on γ-H2AX foci detection. Int J Radiat Biol 2021; 98:1-10. [PMID: 34705602 DOI: 10.1080/09553002.2022.1998706] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
INTRODUCTION In the event of a radiation accident detecting γ-H2AX foci is being accepted as fast method for triage and dose assessment. However, due to their disappearance kinetics, published calibrations have been constructed at specific post-irradiation times. OBJECTIVES To develop a surface, or tridimensional, model to estimate doses at times not included in the calibration analysis, and to validate it. MATERIALS AND METHODS Calibration data was obtained irradiating peripheral mononucleated cells from one donor with radiation doses ranging from 0 to 3 Gy, and γ -H2AX foci were detected microscopically using a semi-automatic method, at different post-irradiation times from 0.5 to 24 h. For validation, in addition to the above-mentioned donor, blood samples from another donor were also used. Validation was done within the range of doses and post-irradiation times used in the calibration. RESULTS The calibration data clearly shows that at each analyzed time, the γ-H2AX foci frequency increases as dose increases, and for each dose this frequency decreases with post-irradiation time. The γ-H2AX foci nucleus distribution was clearly overdispersed, for this reason to obtain bidimensional and tridimensional dose-effect relationships no probability distribution was assumed, and linear and non-linear least squares weighted regression was used. In the two validation exercises for most evaluated samples, the 95% confidence limits of the estimated dose were between ±0.5 Gy of the real dose. No major differences were observed between donors. CONCLUSION In case of a suspected overexposure to radiation, the surface model here presented allows a correct dose estimation using γ-H2AX foci as biomarker. The advantage of this surface model is that it can be used at any post-irradiation time, in our model between 0.5 and 24 h.
Collapse
Affiliation(s)
- Juan S López
- Unitat d'Antropologia Biològica, Departament de Biologia Animal, Biologia Vegetal i Ecologia, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Mònica Pujol-Canadell
- Unitat d'Antropologia Biològica, Departament de Biologia Animal, Biologia Vegetal i Ecologia, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Pedro Puig
- Departament de Matemàtiques, Universitat Autònoma de Barcelona, Bellaterra, Spain.,Centre de Recerca Matemàtica, Bellaterra, Spain
| | - Montserrat Ribas
- Servei de Radiofísica i Radioprotecció, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Pablo Carrasco
- Servei de Radiofísica i Radioprotecció, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Gemma Armengol
- Unitat d'Antropologia Biològica, Departament de Biologia Animal, Biologia Vegetal i Ecologia, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Joan F Barquinero
- Unitat d'Antropologia Biològica, Departament de Biologia Animal, Biologia Vegetal i Ecologia, Universitat Autònoma de Barcelona, Bellaterra, Spain
| |
Collapse
|
20
|
Endesfelder D, Oestreicher U, Kulka U, Ainsbury EA, Moquet J, Barnard S, Gregoire E, Martinez JS, Trompier F, Ristic Y, Woda C, Waldner L, Beinke C, Vral A, Barquinero JF, Hernandez A, Sommer S, Lumniczky K, Hargitai R, Montoro A, Milic M, Monteiro Gil O, Valente M, Bobyk L, Sevriukova O, Sabatier L, Prieto MJ, Moreno Domene M, Testa A, Patrono C, Terzoudi G, Triantopoulou S, Histova R, Wojcik A. RENEB/EURADOS field exercise 2019: robust dose estimation under outdoor conditions based on the dicentric chromosome assay. Int J Radiat Biol 2021; 97:1181-1198. [PMID: 34138666 DOI: 10.1080/09553002.2021.1941380] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 05/19/2021] [Accepted: 06/02/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE Biological and/or physical assays for retrospective dosimetry are valuable tools to recover the exposure situation and to aid medical decision making. To further validate and improve such biological and physical assays, in 2019, EURADOS Working Group 10 and RENEB performed a field exercise in Lund, Sweden, to simulate various real-life exposure scenarios. MATERIALS AND METHODS For the dicentric chromosome assay (DCA), blood tubes were located at anthropomorphic phantoms positioned in different geometries and were irradiated with a 1.36 TBq 192Ir-source. For each exposure condition, dose estimates were provided by at least one laboratory and for four conditions by 17 participating RENEB laboratories. Three radio-photoluminescence glass dosimeters were placed at each tube to assess reference doses. RESULTS The DCA results were homogeneous between participants and matched well with the reference doses (≥95% of estimates within ±0.5 Gy of the reference). For samples close to the source systematic underestimation could be corrected by accounting for exposure time. Heterogeneity within and between tubes was detected for reference doses as well as for DCA doses estimates. CONCLUSIONS The participants were able to successfully estimate the doses and to provide important information on the exposure scenarios under conditions closely resembling a real-life situation.
Collapse
Affiliation(s)
| | | | - Ulrike Kulka
- Bundesamt für Strahlenschutz, BfS, Oberschleissheim, Germany
| | | | | | | | - Eric Gregoire
- Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France
| | - Juan S Martinez
- Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France
| | - François Trompier
- Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France
| | - Yoann Ristic
- Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France
| | - Clemens Woda
- Helmholtz Zentrum München, Institute of Radiation Medicine, Neuherberg, Germany
| | - Lovisa Waldner
- Department of Translational Medicine, Medical Radiation Physics, Lund University, Malmö, Sweden
| | | | - Anne Vral
- Faculty of Medicine and Health Sciences, Universiteit Gent, Gent, Belgium
| | - Joan-Francesc Barquinero
- Department of Animal Biology, Plant Biology and Ecology, Universitat Autònoma de Barcelona, Bellaterra, Spain
| | - Alfredo Hernandez
- Department of Animal Biology, Plant Biology and Ecology, Universitat Autònoma de Barcelona, Bellaterra, Spain
- Independent Researcher, London, UK
| | | | - Katalin Lumniczky
- Department of Radiobiology and Radiohygiene, Unit of Radiation Medicine, National Public Health Centre, Budapest, Hungary
| | - Rita Hargitai
- Department of Radiobiology and Radiohygiene, Unit of Radiation Medicine, National Public Health Centre, Budapest, Hungary
| | - Alegría Montoro
- Laboratorio de Dosimetría Biológica, Servicio de Protección Radiológica Hospital, Universitario Politécnico la Fe, Valencia, Spain
| | - Mirta Milic
- Institute for Medical Research and Occupational Health Mutagenesis Unit, Zagreb, Croatia
| | - Octávia Monteiro Gil
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
| | - Marco Valente
- Department of Radiation Biological, Armed Forces Biomedical Research Institute, Brétigny-sur-Orge, France
| | - Laure Bobyk
- Department of Radiation Biological, Armed Forces Biomedical Research Institute, Brétigny-sur-Orge, France
| | - Olga Sevriukova
- Department of Expertise and Exposure Monitoring, Radiation Protection Centre, Vilnius, Lithuania
| | - Laure Sabatier
- PROCyTOX, Commissariat à l'Energie Atomique et aux Energies Alternatives, Fontenay-aux-Roses, France
- Graduate School Life Science and Health, Université Paris, Saclay, France
| | - María Jesús Prieto
- Laboratorio de Dosimetría Biológica, Hospital General Universitario Gregorio Marañón, Madrid, Spain
| | - Mercedes Moreno Domene
- Laboratorio de Dosimetría Biológica, Hospital General Universitario Gregorio Marañón, Madrid, Spain
| | - Antonella Testa
- Agenzia Nazionale per le Nuove Tecnologie, L'energia e lo Sviluppo Economico Sostenibile, Rome, Italy
| | - Clarice Patrono
- Agenzia Nazionale per le Nuove Tecnologie, L'energia e lo Sviluppo Economico Sostenibile, Rome, Italy
| | - Georgia Terzoudi
- Health Physics, Radiobiology and Cytogenetics Laboratory, National Centre for Scientific Research 'Demokritos', Athens, Greece
| | - Sotiria Triantopoulou
- Health Physics, Radiobiology and Cytogenetics Laboratory, National Centre for Scientific Research 'Demokritos', Athens, Greece
| | - Rositsa Histova
- Department of Radiobiology, National Centre of Radiobiology and Radiation Protection, Sofia, Bulgaria
| | - Andrzej Wojcik
- Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Sweden
- Institute of Biology, Jan Kochanowski University, Kielce, Poland
| |
Collapse
|
21
|
Lee Y, Lee WJ, Jin YW, Jang S. Interventional radiologists have a higher rate of chromosomal damage due to occupational radiation exposure: a dicentric chromosome assay. Eur Radiol 2021; 31:8256-8263. [PMID: 33876297 DOI: 10.1007/s00330-021-07883-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 02/14/2021] [Accepted: 03/15/2021] [Indexed: 01/01/2023]
Abstract
OBJECTIVES There are growing concerns regarding radiation exposure in medical workers who perform interventional fluoroscopy procedures. Owing to the nature of certain interventional procedures, workers may be subjected to partial-body radiation exposure that is high enough to cause local damage. We aimed to investigate the level of radiation exposure in interventional radiologists in South Korea by performing cytogenetic biodosimetry, particularly focusing on partial-body exposure. METHODS Interventional radiologists (n = 52) completed a questionnaire, providing information about their work history and practices. Blood samples were collected and processed for a dicentric chromosome assay. We determined Papworth's U-value to assess the conformity of dicentrics with the Poisson distribution to estimate the partial-body exposures of the radiologists. RESULTS Radiologists had a higher number of dicentrics than the normal population and industrial radiographers. Indeed, subjects with a U-value of > 1.96, an indicator of heterogeneous exposure, were observed more frequently; 4.67 ± 0.81% of their body was irradiated at an average dose of 4.64 ± 0.67 Gy. Logistic regression analysis revealed that the total duration of all interventional procedures per week was associated with partial-body exposure levels. CONCLUSIONS Our findings suggest that interventional radiologists had greater chromosomal damages than those in other occupational groups, and their partial-body exposure levels might be high enough to cause local damage. Use of special dosimeters to monitor partial-body exposure, as well as restricting the time and frequency of interventional procedures, could help reduce occupational radiation exposure. KEY POINTS • Interventional radiologists had a higher number of dicentrics than the normal population and industrial radiographers. • The level of partial-body exposure of interventional radiologists might be high enough to cause occupational local damage such as a skin cancer in fingers. • Restricting the duration and frequency of interventional procedures might be helpful in reducing occupational radiation exposure.
Collapse
Affiliation(s)
- Younghyun Lee
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea
| | - Won Jin Lee
- Department of Preventive Medicine, Korea University College of Medicine, Seoul, Republic of Korea
| | - Young Woo Jin
- National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea
| | - Seongjae Jang
- Laboratory of Biological Dosimetry, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea.
| |
Collapse
|
22
|
Bensimon Etzol J, Rizzi Y, Gateau T, Guersen J, Pereira B, Gouzou E, Lanaret M, Grand O, Bettencourt C, Bouvet S, Ugolin N, Chevillard S, Boyer L. Biodosimetry in interventional radiology: cutaneous-based immunoassay for anticipating risks of dermatitis. Eur Radiol 2021; 31:7476-7483. [PMID: 33791818 DOI: 10.1007/s00330-021-07885-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 02/01/2021] [Accepted: 03/15/2021] [Indexed: 11/24/2022]
Abstract
OBJECTIVES Interventional radiology procedures expose individuals to ionizing radiation. However, existing dosimetry methods do not provide the dose effectively absorbed to the skin, and do not consider the patient's individual response to irradiation. To resolve this lack of dosimetry data, we developed a new external irradiation biodosimetry device, DosiKit, based on the dose-dependent relationship between irradiation dose and radiation-induced H2AX protein phosphorylation in hair follicles. This new biological method was tested in Clermont-Ferrand University Hospital to evaluate the assay performances in the medical field and to estimate DosiKit sensitivity threshold. METHODS DosiKit was tested over 95 patients treated with neuroradiological interventions. For each intervention, lithium fluoride thermoluminescent dosimeters (TLD) were used to measure total dose received at each hair collection point (lateral and occipital skull areas), and conventional indirect dosimetry parameters were collected with a Dosimetry Archiving and Communication System (DACS). RESULTS Quantitative measurement of radiation-induced H2AX protein phosphorylation was performed on 174 hair samples before and after the radiation exposure and 105 samples showed a notable induction of gammaH2AX protein after the radiological procedure. According to a statistical analysis, the threshold sensitivity of the DosiKit immunoassay was estimated around 700 mGy. CONCLUSIONS With this study, we showed that DosiKit provides a useful way for mapping the actually absorbed doses, allowing to identify patients overexposed in interventional radiology procedures, and thus for anticipating risk of developing dermatitis. KEY POINTS • DosiKit is a new external irradiation biodosimetry device, based on the dose-dependent relationship between irradiation dose and radiation-induced H2AX protein phosphorylation in hair follicles. • DosiKit was tested over 95 patients treated with neuroradiological interventions. • The threshold sensitivity of the DosiKit immunoassay was estimated around 700 mGy and DosiKit provides a useful way for mapping the actually absorbed doses.
Collapse
Affiliation(s)
| | - Yassine Rizzi
- Service de Radiologie CHU Gabriel-Montpied, Clermont-Ferrand, France
| | - Theo Gateau
- Service de Radiologie CHU Gabriel-Montpied, Clermont-Ferrand, France
| | - Joel Guersen
- Service de Radiologie CHU Gabriel-Montpied, Clermont-Ferrand, France
| | - Bruno Pereira
- Unité de Biostatistiques (DRCI), CHU Gabriel-Montpied, Clermont-Ferrand, France
| | - Emmanuel Gouzou
- Service de Radiologie CHU Gabriel-Montpied, Clermont-Ferrand, France
| | - Mathieu Lanaret
- Service de Radiologie CHU Gabriel-Montpied, Clermont-Ferrand, France
| | - Oceane Grand
- Service de Radiologie CHU Gabriel-Montpied, Clermont-Ferrand, France
| | | | | | - Nicolas Ugolin
- Commissariat à l'Energie Atomique (CEA), Fontenay-aux-Roses, France
| | | | - Louis Boyer
- Service de Radiologie CHU Gabriel-Montpied, Clermont-Ferrand, France.,TGI Institut Pascal UMR 6602 CNRS UCA SIGMA, Clermont-Ferrand, France
| |
Collapse
|
23
|
Abstract
The dicentric chromosome (DC) assay accurately quantifies exposure to radiation; however, manual and semi-automated assignment of DCs has limited its use for a potential large-scale radiation incident. The Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) software automates unattended DC detection and determines radiation exposures, fulfilling IAEA criteria for triage biodosimetry. This study evaluates the throughput of high-performance ADCI (ADCI-HT) to stratify exposures of populations in 15 simulated population scale radiation exposures. ADCI-HT streamlines dose estimation using a supercomputer by optimal hierarchical scheduling of DC detection for varying numbers of samples and metaphase cell images in parallel on multiple processors. We evaluated processing times and accuracy of estimated exposures across census-defined populations. Image processing of 1744 samples on 16,384 CPUs required 1 h 11 min 23 s and radiation dose estimation based on DC frequencies required 32 sec. Processing of 40,000 samples at 10 exposures from five laboratories required 25 h and met IAEA criteria (dose estimates were within 0.5 Gy; median = 0.07). Geostatistically interpolated radiation exposure contours of simulated nuclear incidents were defined by samples exposed to clinically relevant exposure levels (1 and 2 Gy). Analysis of all exposed individuals with ADCI-HT required 0.6–7.4 days, depending on the population density of the simulation.
Collapse
|
24
|
Alsbeih GA, Al-Hadyan KS, Al-Harbi NM, Bin Judia SS, Moftah BA. Establishing a Reference Dose-Response Calibration Curve for Dicentric Chromosome Aberrations to Assess Accidental Radiation Exposure in Saudi Arabia. Front Public Health 2021; 8:599194. [PMID: 33425838 PMCID: PMC7793750 DOI: 10.3389/fpubh.2020.599194] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Accepted: 10/30/2020] [Indexed: 01/17/2023] Open
Abstract
In cases of nuclear and radiological accidents, public health and emergency response need to assess the magnitude of radiation exposure regardless of whether they arise from disaster, negligence, or deliberate act. Here we report the establishment of a national reference dose–response calibration curve (DRCC) for dicentric chromosome (DC), prerequisite to assess radiation doses received in accidental exposures. Peripheral blood samples were collected from 10 volunteers (aged 20–40 years, median = 29 years) of both sexes (three females and seven males). Blood samples, cytogenetic preparation, and analysis followed the International Atomic Energy Agency EPR-Biodosimetry 2011 report. Irradiations were performed using 320 kVp X-rays. Metafer system was used for automated and assisted (elimination of false-positives and inclusion of true-positives) metaphases findings and DC scoring. DC yields were fit to a linear–quadratic model. Results of the assisted DRCC showed some variations among individuals that were not statistically significant (homogeneity test, P = 0.66). There was no effect of age or sex (P > 0.05). To obtain representative national DRCC, data of all volunteers were pooled together and analyzed. The fitted parameters of the radiation-induced DC curve were as follows: Y = 0.0020 (±0.0002) + 0.0369 (±0.0019) *D + 0.0689 (±0.0009) *D2. The high significance of the fitted coefficients (z-test, P < 0.0001), along with the close to 1.0 p-value of the Poisson-based goodness of fit (χ2 = 3.51, degrees of freedom = 7, P = 0.83), indicated excellent fitting with no trend toward lack of fit. The curve was in the middle range of DRCCs published in other populations. The automated DRCC over and under estimated DCs at low (<1 Gy) and high (>2 Gy) doses, respectively, with a significant lack of goodness of fit (P < 0.0001). In conclusion, we have established the reference DRCC for DCs induced by 320 kVp X-rays. There was no effect of age or sex in this cohort of 10 young adults. Although the calibration curve obtained by the automated (unsupervised) scoring misrepresented dicentric yields at low and high doses, it can potentially be useful for triage mode to segregate between false-positive and near 2-Gy exposures from seriously irradiated individuals who require hospitalization.
Collapse
Affiliation(s)
- Ghazi A Alsbeih
- Radiation Biology Section, Biomedical Physics Department, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.,College of Medicine, Alfaisal University, Riyadh, Saudi Arabia
| | - Khaled S Al-Hadyan
- Radiation Biology Section, Biomedical Physics Department, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia
| | - Najla M Al-Harbi
- Radiation Biology Section, Biomedical Physics Department, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia
| | - Sara S Bin Judia
- Radiation Biology Section, Biomedical Physics Department, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia
| | - Belal A Moftah
- Radiation Biology Section, Biomedical Physics Department, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.,Medical Physics Unit, Department of Oncology, McGill University, Montreal, QC, Canada
| |
Collapse
|
25
|
Endesfelder D, Kulka U, Einbeck J, Oestreicher U. Improving the accuracy of dose estimates from automatically scored dicentric chromosomes by accounting for chromosome number. Int J Radiat Biol 2020; 96:1571-1584. [PMID: 33001765 DOI: 10.1080/09553002.2020.1829152] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
PURPOSE The traditional workflow for biological dosimetry based on manual scoring of dicentric chromosomes is very time consuming. Especially for large-scale scenarios or for low-dose exposures, high cell numbers have to be analyzed, requiring alternative scoring strategies. Semi-automatic scoring of dicentric chromosomes provides an opportunity to speed up the standard workflow of biological dosimetry. Due to automatic metaphase and chromosome detection, the number of counted chromosomes per metaphase is variable. This can potentially introduce overdispersion and statistical methods for conventional, manual scoring might not be applicable to data obtained by automatic scoring of dicentric chromosomes, potentially resulting in biased dose estimates and underestimated uncertainties. The identification of sources for overdispersion enables the development of methods appropriately accounting for increased dispersion levels. MATERIALS AND METHODS Calibration curves based on in vitro irradiated (137-Cs; 0.44 Gy/min) blood from three healthy donors were analyzed for systematic overdispersion, especially at higher doses (>2 Gy) of low LET radiation. For each donor, 12 doses in the range of 0-6 Gy were scored semi-automatically. The effect of chromosome number as a potential cause for the observed overdispersion was assessed. Statistical methods based on interaction models accounting for the number of detected chromosomes were developed for the estimation of calibration curves, dose and corresponding uncertainties. The dose estimation was performed based on a Bayesian Markov-Chain-Monte-Carlo method, providing high flexibility regarding the implementation of priors, likelihood and the functional form of the association between predictors and dicentric counts. The proposed methods were validated by simulations based on cross-validation. RESULTS Increasing dose dependent overdispersion was observed for all three donors as well as considerable differences in dicentric counts between donors. Variations in the number of detected chromosomes between metaphases were identified as a major source for the observed overdispersion and the differences between donors. Persisting overdispersion beyond the contribution of chromosome number was modeled by a Negative Binomial distribution. Results from cross-validation suggested that the proposed statistical methods for dose estimation reduced bias in dose estimates, variability between dose estimates and improved the coverage of the estimated confidence intervals. However, the 95% confidence intervals were still slightly too permissive, suggesting additional unknown sources of apparent overdispersion. CONCLUSIONS A major source for the observed overdispersion could be identified, and statistical methods accounting for overdispersion introduced by variations in the number of detected chromosomes were developed, enabling more robust dose estimation and quantification of uncertainties for semi-automatic counting of dicentric chromosomes.
Collapse
Affiliation(s)
- David Endesfelder
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection, Neuherberg, Germany
| | - Ulrike Kulka
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection, Neuherberg, Germany.,Department of National and International Cooperation, Federal Office for Radiation Protection, Neuherberg, Germany
| | - Jochen Einbeck
- Department of Mathematical Sciences, Durham University, Durham, UK
| | - Ursula Oestreicher
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection, Neuherberg, Germany
| |
Collapse
|
26
|
Bucher M, Duchrow L, Endesfelder D, Roessler U, Gomolka M. Comparison of inexperienced operators and experts in γH2A.X and 53BP1 foci assay for high-throughput biodosimetry approaches in a mass casualty incident. Int J Radiat Biol 2020; 96:1263-1273. [PMID: 32673132 DOI: 10.1080/09553002.2020.1793024] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
PURPOSE In case of population exposure by ionizing radiation, a fast and reliable dose assessment of exposed and non-exposed individuals is crucial important. In initial triage, physicians have to take fast decisions whom to treat with adequate medical care. In addition, worries about significant exposure can be taken away from hundreds to thousands non- or low exposed individuals. Studies have shown that the γH2A.X radiation-induced foci assay is a promising test for fast triage decisions. However, in a large-scale scenario most biodosimetry laboratories will quickly reach their capacity limit. The aim of this study was to evaluate the benefit of inexperienced experimenters to speed up the foci assay and manual foci scoring. MATERIALS AND METHODS The participants of two training courses performed the radiation-induced foci assay (γH2A.X) under the guidance of experts and scored foci (γH2A.X and 53BP1) on sham-irradiated and irradiated blood samples (0.05-1.5 Gy). The outcome of laboratory experiments and manual foci scoring by 26 operators with basic experience in laboratory work was statistically analyzed in comparison to the results from experts. RESULTS Inexperienced operators prepared slides with significant dose-effects (0, 0.1 and 1.0 Gy) for semi-automatic microscopic analyses. Manual foci scoring by inexperienced scorer resulted in a dose-effect curve for γH2A.X, 53BP1 and co-localized foci. In addition, inexperienced scorers were able to distinguish low irradiation doses from unirradiated cells. While 53BP1 foci scoring was in accordance to the expert counting, differences between beginners and expert increased for γH2A.X or co-localized foci. CONCLUSIONS In case of a large-scale radiation event, inexperienced staff is useful to support laboratories in slide preparation for semi-automatic foci counting as well as γH2A.X and 53BP1 manual foci scoring for triage-mode biodosimetry. Slides can be clearly classified in the non-, low- or high-exposed category.
Collapse
Affiliation(s)
- Martin Bucher
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection, Neuherberg, Germany
| | - Lukas Duchrow
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection, Neuherberg, Germany
| | - David Endesfelder
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection, Neuherberg, Germany
| | - Ute Roessler
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection, Neuherberg, Germany
| | - Maria Gomolka
- Department of Effects and Risks of Ionising and Non-Ionising Radiation, Federal Office for Radiation Protection, Neuherberg, Germany
| |
Collapse
|
27
|
Subramanian U, O'Brien B, McNamara M, Romanyukha L, Bolduc DL, Olsen C, Blakely WF. Automated Dicentric Aberration Scoring for Triage Dose Assessment: 60Co Gamma Ray Dose-response at Different Dose Rates. HEALTH PHYSICS 2020; 119:52-58. [PMID: 32483043 DOI: 10.1097/hp.0000000000001285] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The objective of this study was to establish radiation dose-response calibration curves using automated dicentric scoring to support rapid and accurate cytogenetic triage dose-assessment. Blood was drawn from healthy human volunteers and exposed to Co gamma rays at several dose rates (i.e., 1.0, 0.6, and 0.1 Gy min). After radiation, the blood was placed for 2 h in a 37 °C incubator for repair. Blood was then cultured in complete media to which a mitogen (i.e., phytoghemagglutinin, concentration 4%) was added for 48 h. Colcemid was added to the culture at a final concentration of 0.2 μg mL after 24 h for the purpose of arresting first-division metaphase mitotics. Cells were harvested at the end of 48 h. Samples were processed using an automated metaphase harvester and automated microscope metaphase finder equipped with a suite of software including a specialized automated dicentric scoring application. The data obtained were used to create dose-response tables of dicentric yields. The null hypothesis that the data is Poisson-distributed could not be rejected at the significance level of α = 0.05 using results from a Shiny R Studio application (goodness-of-fit Poisson). Calibration curves based on linear-quadratic fits for Co gamma rays at the three different dose rates were generated using these data. The calibration curves were used to detect blind test cases. In conclusion, using the automated harvester and automated microscope metaphase finder with associated automated dicentric scoring software demonstrates high-throughput with suitable accuracy for triage radiation dose assessment.
Collapse
Affiliation(s)
- Uma Subramanian
- Scientific Research Department, Armed Forces Radiobiology Research Institute (AFRRI), Uniformed Services University of the Health Sciences (USUHS), Bethesda, MD 20889-5648
| | - Brett O'Brien
- Scientific Research Department, Armed Forces Radiobiology Research Institute (AFRRI), Uniformed Services University of the Health Sciences (USUHS), Bethesda, MD 20889-5648
| | - Maureen McNamara
- Scientific Research Department, Armed Forces Radiobiology Research Institute (AFRRI), Uniformed Services University of the Health Sciences (USUHS), Bethesda, MD 20889-5648
| | - Lyudmila Romanyukha
- Scientific Research Department, Armed Forces Radiobiology Research Institute (AFRRI), Uniformed Services University of the Health Sciences (USUHS), Bethesda, MD 20889-5648
| | - David L Bolduc
- Scientific Research Department, Armed Forces Radiobiology Research Institute (AFRRI), Uniformed Services University of the Health Sciences (USUHS), Bethesda, MD 20889-5648
| | - Cara Olsen
- Preventive Medicine and Biostatistics Department (PMB), Uniformed Services University of the Health Sciences (USUHS), Bethesda, MD 20814-4799
| | - William F Blakely
- Scientific Research Department, Armed Forces Radiobiology Research Institute (AFRRI), Uniformed Services University of the Health Sciences (USUHS), Bethesda, MD 20889-5648
| |
Collapse
|
28
|
Ryan TL, Escalona MB, Smith TL, Albanese J, Iddins CJ, Balajee AS. Optimization and validation of automated dicentric chromosome analysis for radiological/nuclear triage applications. MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS 2019; 847:503087. [PMID: 31699339 DOI: 10.1016/j.mrgentox.2019.503087] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Revised: 07/26/2019] [Accepted: 09/02/2019] [Indexed: 10/25/2022]
Abstract
Dicentric Chromosome Assay (DCA) is the most preferred cytogenetic technique for absorbed radiation dose assessment in exposed humans. However, DCA is somewhat impractical for triage application owing to its labor intensive and time consuming nature. Although lymphocyte culture for 48 h in vitro is inevitable for DCA, manual scoring of dicentric chromosomes (DCs) requires an additional time of 24-48 h, making the overall turnaround time of 72-96 h for dose estimation. To accelerate the speed of DC analysis for dose estimation, an automated tool was optimized and validated for triage mode of scoring. Several image training files were created to improve the specificity of automated DC analysis algorithm. Accuracy and efficiency of the automated (unsupervised) DC scoring was compared with the semi-automated scoring that involved human verification and correction of DCs (elimination of false positives and inclusion of true positives). DC scoring was performed by both automated and semi-automated modes for different doses of X-rays and γ-rays (0 Gy-5 Gy). Biodoses estimated from the frequencies of DCs detected by both automated (unsupervised) and semi-automated (supervised) scoring modes were grossly similar to the actual delivered doses in the range of 0.5 to 3 Gy of low LET radiation. We suggest that the automated DC tool can be effectively used for large scale radiological/nuclear incidents where a rapid segregation is essential for prioritizing moderately or severely exposed humans to receive appropriate medical countermeasures.
Collapse
Affiliation(s)
- Terri L Ryan
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Maria B Escalona
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Tammy L Smith
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Joseph Albanese
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, CT, USA
| | - Carol J Iddins
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA
| | - Adayabalam S Balajee
- Radiation Emergency Assistance Center/Training Site, Cytogenetic Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, TN 37830, USA.
| |
Collapse
|
29
|
Ryan TL, Pantelias AG, Terzoudi GI, Pantelias GE, Balajee AS. Use of human lymphocyte G0 PCCs to detect intra- and inter-chromosomal aberrations for early radiation biodosimetry and retrospective assessment of radiation-induced effects. PLoS One 2019; 14:e0216081. [PMID: 31059552 PMCID: PMC6502328 DOI: 10.1371/journal.pone.0216081] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Accepted: 04/12/2019] [Indexed: 12/13/2022] Open
Abstract
A sensitive biodosimetry tool is required for rapid individualized dose estimation and risk assessment in the case of radiological or nuclear mass casualty scenarios to prioritize exposed humans for immediate medical countermeasures to reduce radiation related injuries or morbidity risks. Unlike the conventional Dicentric Chromosome Assay (DCA), which takes about 3–4 days for radiation dose estimation, cell fusion mediated Premature Chromosome Condensation (PCC) technique in G0 lymphocytes can be rapidly performed for radiation dose assessment within 6–8 hrs of sample receipt by alleviating the need for ex vivo lymphocyte proliferation for 48 hrs. Despite this advantage, the PCC technique has not yet been fully exploited for radiation biodosimetry. Realizing the advantage of G0 PCC technique that can be instantaneously applied to unstimulated lymphocytes, we evaluated the utility of G0 PCC technique in detecting ionizing radiation (IR) induced stable and unstable chromosomal aberrations for biodosimetry purposes. Our study demonstrates that PCC coupled with mFISH and mBAND techniques can efficiently detect both numerical and structural chromosome aberrations at the intra- and inter-chromosomal levels in unstimulated T- and B-lymphocytes. Collectively, we demonstrate that the G0 PCC technique has the potential for development as a biodosimetry tool for detecting unstable chromosome aberrations (chromosome fragments and dicentric chromosomes) for early radiation dose estimation and stable chromosome exchange events (translocations) for retrospective monitoring of individualized health risks in unstimulated lymphocytes.
Collapse
Affiliation(s)
- Terri L. Ryan
- Cytogenetic Biodosimetry Laboratory, Radiation Emergency Assistance Center/Training site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, Tennessee, United States of America
| | - Antonio G. Pantelias
- Health Physics, Radiobiology & Cytogenetics Laboratory, Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Centre for Scientific Research “Demokritos”, Ag. Paraskevi, Athens, Greece
| | - Georgia I. Terzoudi
- Health Physics, Radiobiology & Cytogenetics Laboratory, Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Centre for Scientific Research “Demokritos”, Ag. Paraskevi, Athens, Greece
| | - Gabriel E. Pantelias
- Health Physics, Radiobiology & Cytogenetics Laboratory, Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Centre for Scientific Research “Demokritos”, Ag. Paraskevi, Athens, Greece
| | - Adayabalam S. Balajee
- Cytogenetic Biodosimetry Laboratory, Radiation Emergency Assistance Center/Training site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, Oak Ridge, Tennessee, United States of America
- * E-mail:
| |
Collapse
|
30
|
Balajee AS, Escalona M, Iddins CJ, Shuryak I, Livingston GK, Hanlon D, Dainiak N. Development of electronic training and telescoring tools to increase the surge capacity of dicentric chromosome scorers for radiological/nuclear mass casualty incidents. Appl Radiat Isot 2018; 144:111-117. [PMID: 30572199 DOI: 10.1016/j.apradiso.2018.12.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 11/02/2018] [Accepted: 12/04/2018] [Indexed: 11/16/2022]
Abstract
Dicentric chromosome assay (DCA) is most frequently used for estimating the absorbed radiation dose in the peripheral blood lymphocytes of humans after occupational or incidental radiation exposure. DCA is considered to be the "gold standard" for estimating the absorbed radiation dose because the dicentric chromosome formation is fairly specific to ionizing radiation exposure and its baseline frequency is extremely low in non-exposed humans. However, performance of DCA for biodosimetry is labor intensive and time-consuming making its application impractical for radiological/nuclear mass casualty incidents. Realizing the critical need for rapid dose estimation particularly after radiological/nuclear disaster events, several laboratories have initiated efforts to automate some of the procedural steps involved in DCA. Although metaphase image capture and dicentric chromosome analysis have been automated using commercially available platforms, lack or an insufficient number of these platforms may pose a serious bottleneck when hundreds and thousands of samples need to be analyzed for rapid dose estimation. To circumvent this problem, a web-based approach for telescoring was initiated by our laboratory, which enabled the cytogeneticists around the globe to analyze and score digital images. To further increase the surge capacity of dicentric scorers, we recently initiated a dicentric training and scoring exercise involving a total of 50 volunteers at all academic levels without any prerequisite for experience in radiation cytogenetics. Out of the 50 volunteers enrolled thus far, only one outlier was found who overestimated the absorbed radiation dose. Our approach of training the civilians in dicentric chromosome analysis holds great promise for increasing the surge capacity of dicentric chromosome scorers for a rapid biodosimetry in the case of mass casualty scenarios.
Collapse
Affiliation(s)
- Adayabalam S Balajee
- Radiation Emergency Assistance Center and Training Site, Cytogenetics Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA.
| | - Maria Escalona
- Radiation Emergency Assistance Center and Training Site, Cytogenetics Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Carol J Iddins
- Radiation Emergency Assistance Center and Training Site, Cytogenetics Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Igor Shuryak
- Center for Radiological Research, Department of Radiation Oncology, Columbia University Medical Center, New York City, NY, USA
| | - Gordon K Livingston
- Radiation Emergency Assistance Center and Training Site, Cytogenetics Biodosimetry Laboratory, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Don Hanlon
- Department of Health, Energy and Environment-Health, Oak Ridge Associated Universities, Oak Ridge, TN, USA
| | - Nicholas Dainiak
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, CT, USA
| |
Collapse
|
31
|
Balajee AS, Smith T, Ryan T, Escalona M, Dainiak N. DEVELOPMENT OF A MINIATURIZED VERSION OF DICENTRIC CHROMOSOME ASSAY TOOL FOR RADIOLOGICAL TRIAGE. RADIATION PROTECTION DOSIMETRY 2018; 182:139-145. [PMID: 30247729 DOI: 10.1093/rpd/ncy127] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Indexed: 06/08/2023]
Abstract
Use of ionizing radiation (IR) in various industrial, medical and other applications can potentially increase the risk of medical, occupational or accidental human exposure. Additionally, in the event of a radiological or nuclear (R/N) incident, several tens of hundreds and thousands of people are likely to be exposed to IR. IR causes serious health effects including mortality from acute radiation syndrome and therefore it is imperative to determine the absorbed radiation dose, which will enable physicians in making an appropriate clinical 'life-saving' decision. The 'Dicentric Chromosome Assay (DCA)' is the gold standard for estimating the absorbed radiation dose but its performance is time consuming and laborious. Further, timely evaluation of dicentric chromosomes (DCs) for dose estimation in a large number of samples provides a bottleneck because of a limited number of trained personnel and a prolonged time for manual analysis. To circumvent some of these technical issues, we developed and optimized a miniaturized high throughput version of DCA (mini-DCA) in a 96-microtube matrix with bar-coded 1.4 ml tubes to enable the processing of a large number of samples. To increase the speed of DC analysis for radiation dose estimation, a semi-automated scoring was optimized using the Metafer DCScore algorithm. The accuracy of mini-DCA in dose estimation was verified and validated though comparison with conventional DCA performed in 15 ml conical tubes. The mini-DCA considerably reduced the sample processing time by a factor of 4 when compared to the conventional DCA. Further, the radiation doses estimated by mini-DCA using the triage mode of scoring (50 cells or 30 DCs) were similar to that of conventional DCA using 300-500 cells. The mini-DCA coupled with semi-automated DC scoring not only reduced the sample processing and analysis times by a factor of 4 but also enabled the processing of a large number of samples at once. Our mini-DCA method, once automated for high throughput robotic platforms, will be an effective radiological triage tool for mass casualty incidents.
Collapse
Affiliation(s)
- Adayabalam S Balajee
- Cytogenetics Biodosimetry Laboratory, Radiation Emergency Assistance Center and Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Tammy Smith
- Cytogenetics Biodosimetry Laboratory, Radiation Emergency Assistance Center and Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Terri Ryan
- Cytogenetics Biodosimetry Laboratory, Radiation Emergency Assistance Center and Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Maria Escalona
- Cytogenetics Biodosimetry Laboratory, Radiation Emergency Assistance Center and Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| | - Nicholas Dainiak
- Cytogenetics Biodosimetry Laboratory, Radiation Emergency Assistance Center and Training Site, Oak Ridge Institute for Science and Education, Oak Ridge Associated Universities, 1299, Bethel Valley Road, Oak Ridge, TN, USA
| |
Collapse
|
32
|
Einbeck J, Ainsbury EA, Sales R, Barnard S, Kaestle F, Higueras M. A statistical framework for radiation dose estimation with uncertainty quantification from the γ-H2AX assay. PLoS One 2018; 13:e0207464. [PMID: 30485322 PMCID: PMC6261578 DOI: 10.1371/journal.pone.0207464] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Accepted: 10/31/2018] [Indexed: 11/18/2022] Open
Abstract
Over the last decade, the γ–H2AX focus assay, which exploits the phosphorylation of the H2AX histone following DNA double–strand–breaks, has made considerable progress towards acceptance as a reliable biomarker for exposure to ionizing radiation. While the existing literature has convincingly demonstrated a dose–response effect, and also presented approaches to dose estimation based on appropriately defined calibration curves, a more widespread practical use is still hampered by a certain lack of discussion and agreement on the specific dose–response modelling and uncertainty quantification strategies, as well as by the unavailability of implementations. This manuscript intends to fill these gaps, by stating explicitly the statistical models and techniques required for calibration curve estimation and subsequent dose estimation. Accompanying this article, a web applet has been produced which implements the discussed methods.
Collapse
Affiliation(s)
- Jochen Einbeck
- Department of Mathematical Sciences, Durham University, Durham, United Kingdom
- * E-mail:
| | - Elizabeth A. Ainsbury
- Public Health England, Chemical and Environmental Hazards, Chilton, Didcot, United Kingdom
| | - Rachel Sales
- Department of Mathematical Sciences, Durham University, Durham, United Kingdom
| | - Stephen Barnard
- Public Health England, Chemical and Environmental Hazards, Chilton, Didcot, United Kingdom
| | - Felix Kaestle
- Bundesamt für Strahlenschutz, Fachbereich Strahlenschutz und Gesundheit, Oberschleissheim, Germany
| | - Manuel Higueras
- Departamento de Matemáticas y Computación, Universidad de La Rioja, Logroño, La Rioja, Spain
- Basque Center for Applied Mathematics, Bilbao, Basque Country, Spain
| |
Collapse
|
33
|
Oestreicher U, Endesfelder D, Gomolka M, Kesminiene A, Lang P, Lindholm C, Rößler U, Samaga D, Kulka U. Automated scoring of dicentric chromosomes differentiates increased radiation sensitivity of young children after low dose CT exposure in vitro. Int J Radiat Biol 2018; 94:1017-1026. [PMID: 30028637 DOI: 10.1080/09553002.2018.1503429] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 05/28/2018] [Accepted: 06/29/2018] [Indexed: 12/12/2022]
Abstract
PURPOSE Automated detection of dicentric chromosomes from a large number of cells was applied to study age-dependent radiosensitivity after in vitro CT exposure of blood from healthy donors. MATERIALS AND METHODS Blood samples from newborns, children (2-5 years) and adults (20-50 years) were exposed in vitro to 0 mGy, 41 mGy and 978 mGy using a CT equipment. In this study, automated scoring based on 13,000-31,000 cells/dose point/age group was performed. Results for control and low dose points were validated by manually counting about 26,000 cells/dose point/age group. RESULTS For all age groups, the high number of analyzed cells enabled the detection of a significant increase in the frequency of radiation induced dicentric chromosomes in cells exposed to 41 mGy as compared to control cells. Moreover, differences between the age groups could be resolved for the low dose: young donors showed significantly increased risk for induced dicentrics at 41 mGy compared to adults. CONCLUSIONS The results very clearly demonstrate that the automated dicentric scoring method is capable of discerning radiation induced biomarkers in the low dose range (<100 mGy) and thus may open possibilities for large-scale molecular epidemiology studies in radiation protection.
Collapse
Affiliation(s)
- Ursula Oestreicher
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
| | - David Endesfelder
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
| | - Maria Gomolka
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
| | | | - Peter Lang
- c Department of Radiation Oncology , University Hospital, LMU , Munich , Germany
| | - Carita Lindholm
- d Radiation and Nuclear Safety Authority, STUK , Helsinki , Finland
| | - Ute Rößler
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
| | - Daniel Samaga
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
- e Research Unit Radiation Cytogenetics , Helmholtz Zentrum Muenchen , Oberschleissheim , Germany
| | - Ulrike Kulka
- a Federal Office for Radiation Protection (BfS) , Oberschleissheim , Germany
| |
Collapse
|
34
|
Dai H, Feng J, Bian H, Chen W, Wang Y, Liu Y, Hu W. Complete Technical Scheme for Automatic Biological Dose Estimation Platform. Dose Response 2018; 16:1559325818799951. [PMID: 30302068 PMCID: PMC6170965 DOI: 10.1177/1559325818799951] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2018] [Revised: 08/02/2018] [Accepted: 08/07/2018] [Indexed: 11/29/2022] Open
Abstract
To establish a complete technical solution for the automatic radiation biological dose estimation platform for biological dose estimation and classification of the wounded in large-scale radiation accidents, the “dose–effect curve by dicentric chromosome (DIC) automatic analysis” was established and its accuracy was verified. The effects of analyzed cell number and the special treatment of the culture on dose estimation by DIC automatic analysis were studied. Besides, sample processing capabilities of the special equipments were tested. The fitted “dose–effect curve by DIC automatic analysis” was presented as follows: Y = (0.01806 ± 0.00032) D2 + (0.01279 ± 0.00084) D + (0.0004891 ± 0.0001358) (R2 = 0.961). Three-gradient scanning method, culture refrigeration method, and interprofessional collaboration under extreme conditions were proposed to improve the detection speed, prolong the sample processing time window, and reduce the equipment investment. In addition, the optimized device allocation ratio for the automatic biological dose estimation laboratory was proposed to eliminate the efficiency bottleneck. The complete set of technical solutions for the high-throughput automatic biological dose estimation laboratory proposed in this study can meet the requirements of early classification and rapid biological dose assessment of the wounded during the large-scale nuclear radiation events, and it is worthy of further promotion.
Collapse
Affiliation(s)
- Hong Dai
- Department of Nuclear Accident Medical Emergency, The Second Affiliated Hospital of Soochow University, Suzhou, China
| | - Junchao Feng
- Department of Nuclear Accident Medical Emergency, The Second Affiliated Hospital of Soochow University, Suzhou, China
| | - Huahui Bian
- Department of Nuclear Accident Medical Emergency, The Second Affiliated Hospital of Soochow University, Suzhou, China
| | - Weibo Chen
- Department of Nuclear Accident Medical Emergency, The Second Affiliated Hospital of Soochow University, Suzhou, China
| | - Youyou Wang
- Department of Nuclear Accident Medical Emergency, The Second Affiliated Hospital of Soochow University, Suzhou, China
| | - Yulong Liu
- Department of Nuclear Accident Medical Emergency, The Second Affiliated Hospital of Soochow University, Suzhou, China.,Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou, China
| | - Wentao Hu
- School of Radiation Medicine and Protection, Medical College of Soochow University, Suzhou, China.,Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou, China
| |
Collapse
|
35
|
Bensimon Etzol J, Bouvet S, Bettencourt C, Altmeyer S, Paget V, Ugolin N, Chevillard S. DosiKit, a New Immunoassay for Fast Radiation Biodosimetry of Hair and Blood Samples. Radiat Res 2018; 190:473-482. [DOI: 10.1667/rr15136.1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
| | | | | | | | - Vincent Paget
- Commissariat à l'Energie Atomique (CEA), Fontenay-aux-Roses France
| | - Nicolas Ugolin
- Commissariat à l'Energie Atomique (CEA), Fontenay-aux-Roses France
| | | |
Collapse
|
36
|
Bensimon Etzol J, Valente M, Altmeyer S, Bettencourt C, Bouvet S, Cosler G, Desangles F, Drouet M, Entine F, Hérodin F, Jourquin F, Lecompte Y, Martigne P, Michel X, Pateux J, Ugolin N, Chevillard S. DosiKit, a New Portable Immunoassay for Fast External Irradiation Biodosimetry. Radiat Res 2017; 190:176-185. [DOI: 10.1667/rr14760.1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
| | - Marco Valente
- Institut de Recherche Biomedicale des Armées (IRBA), Bretigny, France
| | | | | | | | - Guillaume Cosler
- Institut de Recherche Biomedicale des Armées (IRBA), Bretigny, France
| | | | - Michel Drouet
- Institut de Recherche Biomedicale des Armées (IRBA), Bretigny, France
| | - Fabrice Entine
- Service de Protection Radiologique des Armées (SPRA), Clamart, France
| | - Francis Hérodin
- Institut de Recherche Biomedicale des Armées (IRBA), Bretigny, France
| | - Flora Jourquin
- Service de Protection Radiologique des Armées (SPRA), Clamart, France
| | - Yannick Lecompte
- Service de Protection Radiologique des Armées (SPRA), Clamart, France
| | - Patrick Martigne
- Institut de Recherche Biomedicale des Armées (IRBA), Bretigny, France
| | - Xavier Michel
- Service de Protection Radiologique des Armées (SPRA), Clamart, France
| | - Jérôme Pateux
- Institut de Recherche Biomedicale des Armées (IRBA), Bretigny, France
| | - Nicolas Ugolin
- Commissariat à l'Energie Atomique (CEA), Fontenay-aux-Roses, France
| | | |
Collapse
|
37
|
Manivannan B, Kuppusamy T, Venkatesan S, Perumal V. A comparison of estimates of doses to radiotherapy patients obtained with the dicentric chromosome analysis and the γ-H2AX assay: Relevance to radiation triage. Appl Radiat Isot 2017; 131:1-7. [PMID: 29080427 DOI: 10.1016/j.apradiso.2017.10.031] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 10/14/2017] [Accepted: 10/14/2017] [Indexed: 11/18/2022]
Abstract
The γ-H2AX assay was investigated as an alternative to the time-consuming dicentric chromosome assay (DCA). Radiation doses to 25 radiotherapy patients were estimated in parallel by DCA and the γ-H2AX assay. The γ-H2AX assay yielded doses in line with the calculated equivalent whole body doses in 92% of the patients, whereas the success rate of DCA was only 76%. The result shows that the γ-H2AX assay can be effectively used as a rapid and more precise alternative to DCA.
Collapse
Affiliation(s)
- Bhavani Manivannan
- Department of Human Genetics, College of Biomedical Sciences, Technology and Research, Sri Ramachandra University, Porur, Chennai 600116, Tamil Nadu, India.
| | - Thayalan Kuppusamy
- Dr. Kamakshi Memorial Hospital Pvt. Ltd., Pallikaranai, Chennai 600100, Tamil Nadu, India.
| | - Srinivasan Venkatesan
- Dr. Kamakshi Memorial Hospital Pvt. Ltd., Pallikaranai, Chennai 600100, Tamil Nadu, India.
| | - Venkatachalam Perumal
- Department of Human Genetics, College of Biomedical Sciences, Technology and Research, Sri Ramachandra University, Porur, Chennai 600116, Tamil Nadu, India.
| |
Collapse
|
38
|
Wilkins RC, Rodrigues MA, Beaton-Green LA. The Application of Imaging Flow Cytometry to High-Throughput Biodosimetry. Genome Integr 2017; 8:7. [PMID: 28250914 PMCID: PMC5320785 DOI: 10.4103/2041-9414.198912] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Biodosimetry methods, including the dicentric chromosome assay, the cytokinesis-block micronucleus assay and the γH2AX marker of DNA damage are used to determine the dose of ionizing radiation. These techniques are particularly useful when physical dosimetry is absent or questioned. While these assays can be very sensitive and specific, the standard methods need to be adapted to increase sample throughput in the case of a large-scale radiological/nuclear event. Recent modifications to the microscope-based assays have resulted in some increased throughput, and a number of biodosimetry networks have been, and continue to be, established and strengthened. As the imaging flow cytometer (IFC) is a technology that can automatically image and analyze processed blood samples for markers of radiation damage, the microscope-based biodosimetry techniques can be modified for the IFC for high-throughput biological dosimetry. Furthermore, the analysis templates can be easily shared between networked biodosimetry laboratories for increased capacity and improved standardization. This review describes recent advances in IFC methodology and their application to biodosimetry.
Collapse
Affiliation(s)
- Ruth C. Wilkins
- Environmental and Radiation and Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | | | - Lindsay A. Beaton-Green
- Environmental and Radiation and Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| |
Collapse
|
39
|
Vinnikov VA. Optimizing the Microscopy Time Schedule for Chromosomal Dosimetry of High-dose and Partial-body Irradiations. Genome Integr 2017; 8:3. [PMID: 28250910 PMCID: PMC5320789 DOI: 10.4103/2041-9414.198908] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The methodology of cytogenetic triage can be improved by optimizing a schedule of microscopy for different exposure scenarios. Chromosome aberrations were quantified by microscopy in human blood lymphocytes irradiated in vitro to ~2, 4, and 12 Gy acute 60Co γ-rays mixed with the unirradiated blood simulating 10%, 50%, 90%, and 100% exposure and in along with a sample from a homogeneous exposure to ~20 Gy. Biodosimetry workload was statistically modeled assuming that 0.5, 1, 5, or 25 h was available for scoring one case or for analysis of up to 1000 cells or 100 dicentrics plus centric rings by one operator. A strong negative correlation was established between the rates of aberration acquisition and cell recording. Calculations showed that the workload of 1 case per operator per·day (5 h of scoring by microscopy) allows dose estimates with high accuracy for either 90%–100% irradiations of 2 Gy or 50%–90% irradiations of 4–12 Gy; lethal homogeneous (100%) exposures of 12 and 20 Gy can be evaluated with just 1 h of microscopy. Triage analysis of 0.5 h scoring per case results in the minimum tolerable accuracy only for partial- and total-body exposure of 4–20 Gy. Time-related efficacy of conventional biodosimetry depends primarily on the aberration yield in the sample, which is dependent on the radiation dose and its distribution in the patient's body. An optimized schedule of microscopy scoring should be developed for different exposure scenarios in each laboratory to increase their preparedness to radiological emergencies.
Collapse
Affiliation(s)
- Volodymyr A Vinnikov
- Individual Radiosensitivity Group, Grigoriev Institute for Medical Radiology of the National Academy of Medical Science of Ukraine, Kharkiv, Ukraine
| |
Collapse
|
40
|
Romm H, Beinke C, Garcia O, Di Giorgio M, Gregoire E, Livingston G, Lloyd DC, Martìnez-Lopez W, Moquet JE, Sugarman SL, Wilkins RC, Ainsbury EA. A New Cytogenetic Biodosimetry Image Repository for the Dicentric Assay. RADIATION PROTECTION DOSIMETRY 2016; 172:192-200. [PMID: 27412509 DOI: 10.1093/rpd/ncw158] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The BioDoseNet was founded by the World Health Organization as a global network of biodosimetry laboratories for building biodosimetry laboratory capacities in countries. The newly established BioDoseNet image repository is a databank of ~25 000 electronically captured images of metaphases from the dicentric assay, which have been previously analysed by international experts. The detailed scoring results and dose estimations have, in most cases, already been published. The compilation of these images into one image repository provides a valuable tool for training and research purposes in biological dosimetry. No special software is needed to view and score the image galleries. For those new to the dicentric assay, the BioDoseNet Image Repository provides an introduction to and training for the dicentric assay. It is an excellent instrument for intra-laboratory training purposes or inter-comparisons between laboratories, as recommended by the International Organization for Standardisation standards. In the event of a radiation accident, the repository can also increase the surge capacity and reduce the turnaround time for dose estimations. Finally, it provides a mechanism for the discussion of scoring discrepancies in difficult cases.
Collapse
Affiliation(s)
- Horst Romm
- Bundesamt fuer Strahlenschutz, Neuherberg, Salzgitter, Germany
| | | | - Omar Garcia
- Centro de Protección e Higiene de las Radiaciones, Havana, Cuba
| | | | - Eric Gregoire
- Institut de Radioprotection et de Sureté Nucléaire, Fontenay-aux-Roses, France
| | | | | | | | | | | | | | | |
Collapse
|
41
|
Sproull M, Camphausen K. State-of-the-Art Advances in Radiation Biodosimetry for Mass Casualty Events Involving Radiation Exposure. Radiat Res 2016; 186:423-435. [PMID: 27710702 DOI: 10.1667/rr14452.1] [Citation(s) in RCA: 56] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
With the possibility of large-scale terrorist attacks around the world, the need for modeling and development of new medical countermeasures for potential future chemical, biological, radiological and nuclear (CBRN) has been well established. Project Bioshield, initiated in 2004, provided a framework to develop and expedite research in the field of CBRN exposures. To respond to large-scale population exposures from a nuclear event or radiation dispersal device (RDD), new methods for determining received dose using biological modeling became necessary. The field of biodosimetry has advanced significantly beyond this original initiative, with expansion into the fields of genomics, proteomics, metabolomics and transcriptomics. Studies are ongoing to evaluate the use of lymphocyte kinetics for dose assessment, as well as the development of field-deployable EPR technology. In addition, expansion of traditional cytogenetic assessment methods through the use of automated platforms and the development of laboratory surge capacity networks have helped to advance our biodefense preparedness. In this review of the latest advances in the field of biodosimetry we evaluate our progress and identify areas that still need to be addressed to achieve true field-deployment readiness.
Collapse
Affiliation(s)
- Mary Sproull
- Radiation Oncology Branch, National Cancer Institute, Bethesda, Maryland
| | - Kevin Camphausen
- Radiation Oncology Branch, National Cancer Institute, Bethesda, Maryland
| |
Collapse
|
42
|
Badie C, Hess J, Zitzelsberger H, Kulka U. Established and Emerging Biomarkers of Radiation Exposure. Clin Oncol (R Coll Radiol) 2016; 28:619-21. [DOI: 10.1016/j.clon.2016.06.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Accepted: 06/02/2016] [Indexed: 10/21/2022]
|
43
|
Ainsbury EA, Higueras M, Puig P, Einbeck J, Samaga D, Barquinero JF, Barrios L, Brzozowska B, Fattibene P, Gregoire E, Jaworska A, Lloyd D, Oestreicher U, Romm H, Rothkamm K, Roy L, Sommer S, Terzoudi G, Thierens H, Trompier F, Vral A, Woda C. Uncertainty of fast biological radiation dose assessment for emergency response scenarios. Int J Radiat Biol 2016; 93:127-135. [PMID: 27572921 DOI: 10.1080/09553002.2016.1227106] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
PURPOSE Reliable dose estimation is an important factor in appropriate dosimetric triage categorization of exposed individuals to support radiation emergency response. MATERIALS AND METHODS Following work done under the EU FP7 MULTIBIODOSE and RENEB projects, formal methods for defining uncertainties on biological dose estimates are compared using simulated and real data from recent exercises. RESULTS The results demonstrate that a Bayesian method of uncertainty assessment is the most appropriate, even in the absence of detailed prior information. The relative accuracy and relevance of techniques for calculating uncertainty and combining assay results to produce single dose and uncertainty estimates is further discussed. CONCLUSIONS Finally, it is demonstrated that whatever uncertainty estimation method is employed, ignoring the uncertainty on fast dose assessments can have an important impact on rapid biodosimetric categorization.
Collapse
Affiliation(s)
- Elizabeth A Ainsbury
- a Public Health England Centre for Radiation , Chemical and Environmental Hazards (PHE) , Chilton , UK
| | - Manuel Higueras
- a Public Health England Centre for Radiation , Chemical and Environmental Hazards (PHE) , Chilton , UK.,b Universitat Autonoma de Barcelona , Barcelona , Spain
| | - Pedro Puig
- b Universitat Autonoma de Barcelona , Barcelona , Spain
| | - Jochen Einbeck
- c Department of Mathematical Sciences , Durham University , Durham , UK
| | - Daniel Samaga
- d Bundesamt für Strahlenschutz (BfS) , Munich , Germany
| | | | | | - Beata Brzozowska
- e Stockholm University , Centre for Radiation Protection Research, Department of Molecular Bioscience, The Wenner-Gren Institute , Stockholm , Sweden.,f University of Warsaw , Faculty of Physics, Department of Biomedical Physics , Warsaw , Poland
| | | | - Eric Gregoire
- h Institut de radioprotection et de sûreté nucléaire (IRSN) , Paris , France
| | - Alicja Jaworska
- i Norwegian Radiation Protection Authority (NRPA) , Østerås , Norway
| | - David Lloyd
- a Public Health England Centre for Radiation , Chemical and Environmental Hazards (PHE) , Chilton , UK
| | | | - Horst Romm
- d Bundesamt für Strahlenschutz (BfS) , Munich , Germany
| | - Kai Rothkamm
- a Public Health England Centre for Radiation , Chemical and Environmental Hazards (PHE) , Chilton , UK.,j University Medical Center Hamburg-Eppendorf , Hamburg , Germany
| | - Laurence Roy
- h Institut de radioprotection et de sûreté nucléaire (IRSN) , Paris , France
| | - Sylwester Sommer
- k Institute of Nuclear Chemistry and Technology (ICHTJ) , Warsaw , Poland
| | - Georgia Terzoudi
- l National Centre for Scientific Research Demokritos , Athens , Greece
| | | | - Francois Trompier
- h Institut de radioprotection et de sûreté nucléaire (IRSN) , Paris , France
| | - Anne Vral
- m Ghent University , Ghent , Belgium
| | - Clemens Woda
- n Helmholtz Zentrum München (HMGU) , Neuherberg , Germany
| |
Collapse
|
44
|
Trompier F, Burbidge C, Bassinet C, Baumann M, Bortolin E, De Angelis C, Eakins J, Della Monaca S, Fattibene P, Quattrini MC, Tanner R, Wieser A, Woda C. Overview of physical dosimetry methods for triage application integrated in the new European network RENEB. Int J Radiat Biol 2016; 93:65-74. [DOI: 10.1080/09553002.2016.1221545] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
| | - Christopher Burbidge
- C2TN, Instituto Superior Técnico, Universidade de Lisboa, Portugal, now at SUERC, University of Glasgow, UK
| | - Céline Bassinet
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), France
| | - Marion Baumann
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), France
| | | | | | - Jonathan Eakins
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), UK
| | | | | | | | - Rick Tanner
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), UK
| | | | | |
Collapse
|
45
|
Foundations of identifying individual chromosomes by imaging flow cytometry with applications in radiation biodosimetry. Methods 2016; 112:18-24. [PMID: 27524557 DOI: 10.1016/j.ymeth.2016.08.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2016] [Revised: 07/24/2016] [Accepted: 08/08/2016] [Indexed: 11/23/2022] Open
Abstract
Biodosimetry is an important tool for triage in the case of large-scale radiological or nuclear emergencies, but traditional microscope-based methods can be tedious and prone to scorer fatigue. While the dicentric chromosome assay (DCA) has been adapted for use in triage situations, it is still time-consuming to create and score slides. Recent adaptations of traditional biodosimetry assays to imaging flow cytometry (IFC) methods have dramatically increased throughput. Additionally, recent improvements in image analysis algorithms in the IFC software have resulted in improved specificity for spot counting of small events. In the IFC method for the dicentric chromosome analysis (FDCA), lymphocytes isolated from whole blood samples are cultured with PHA and Colcemid. After incubation, lymphocytes are treated with a hypotonic solution and chromosomes are isolated in suspension, labelled with a centromere marker and stained for DNA content with DRAQ5. Stained individual chromosomes are analyzed on the ImageStream®X (EMD-Millipore, Billerica, MA) and mono- and dicentric chromosome populations are identified and enumerated using advanced image processing techniques. Both the preparation of the isolated chromosome suspensions as well as the image analysis methods were fine-tuned in order to optimize the FDCA. In this paper we describe the method to identify and score centromeres in individual chromosomes by IFC and show that the FDCA method may further improve throughput for triage biodosimetry in the case of large-scale radiological or nuclear emergencies.
Collapse
|
46
|
Ainsbury E, Badie C, Barnard S, Manning G, Moquet J, Abend M, Antunes AC, Barrios L, Bassinet C, Beinke C, Bortolin E, Bossin L, Bricknell C, Brzoska K, Buraczewska I, Castaño CH, Čemusová Z, Christiansson M, Cordero SM, Cosler G, Monaca SD, Desangles F, Discher M, Dominguez I, Doucha-Senf S, Eakins J, Fattibene P, Filippi S, Frenzel M, Georgieva D, Gregoire E, Guogyte K, Hadjidekova V, Hadjiiska L, Hristova R, Karakosta M, Kis E, Kriehuber R, Lee J, Lloyd D, Lumniczky K, Lyng F, Macaeva E, Majewski M, Vanda Martins S, McKeever SW, Meade A, Medipally D, Meschini R, M’kacher R, Gil OM, Montero A, Moreno M, Noditi M, Oestreicher U, Oskamp D, Palitti F, Palma V, Pantelias G, Pateux J, Patrono C, Pepe G, Port M, Prieto MJ, Quattrini MC, Quintens R, Ricoul M, Roy L, Sabatier L, Sebastià N, Sholom S, Sommer S, Staynova A, Strunz S, Terzoudi G, Testa A, Trompier F, Valente M, Hoey OV, Veronese I, Wojcik A, Woda C. Integration of new biological and physical retrospective dosimetry methods into EU emergency response plans – joint RENEB and EURADOS inter-laboratory comparisons. Int J Radiat Biol 2016; 93:99-109. [DOI: 10.1080/09553002.2016.1206233] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
- Elizabeth Ainsbury
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Christophe Badie
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Stephen Barnard
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Grainne Manning
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Jayne Moquet
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Michael Abend
- Bundeswehr Institute of Radiobiology (BIR), Munich, Germany
| | - Ana Catarina Antunes
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico (IST/ITN), Universidade de Lisboa, Bobadela-LRS, Portugal
| | | | - Celine Bassinet
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Paris, France
| | - Christina Beinke
- Bundeswehr Institute of Radiobiology affiliated to the University of Ulm (UULM), Munich, Germany
| | | | - Lily Bossin
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
- Durham University (DUR), Durham, UK
| | - Clare Bricknell
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Kamil Brzoska
- Institute of Nuclear Chemistry and Technology (INCT), Warsaw, Poland
| | - Iwona Buraczewska
- Institute of Nuclear Chemistry and Technology (INCT), Warsaw, Poland
| | | | - Zina Čemusová
- Státní ústav radiační ochrany (SÚRO), Prague, Czech Republic
| | | | | | - Guillaume Cosler
- Institut de Recherche Biomédicale des Armées (IRBA), Paris, France
| | | | | | - Michael Discher
- Salzburg University Department of Geography and Geology, Salzburg, Austria
| | | | | | - Jon Eakins
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | | | | | - Monika Frenzel
- PROCyTOX, Commissariat à l’Energie Atomique et aux Energies Alternatives, Université Paris-Saclay (CEA), Fontenay-aux-Roses, France
| | - Dimka Georgieva
- National Center of Radiobiology and Radiation Protection (NCRRP), Bulgaria
| | - Eric Gregoire
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Paris, France
| | | | | | | | - Rositsa Hristova
- National Center of Radiobiology and Radiation Protection (NCRRP), Bulgaria
| | - Maria Karakosta
- Laboratory of Health Physics, Radiobiology & Cytogenetics Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety National Center for Scientific Research “Demokritos” (NCSRD), Greece
| | - Enikő Kis
- National Public Health Centre – National Research Institute for Radiobiology and Radiohygiene (NRIRR), Hungary
| | - Ralf Kriehuber
- Radiation Biology Unit Forschungszentrum Jülich GmbH (FzJ), Jülich, Germany
| | - Jungil Lee
- Korea Atomic Energy Research Institute (KAERI), Daejeon, South Korea
| | - David Lloyd
- Public Health England Centre for Radiation, Chemical and Environmental Hazards (PHE), Chilton, UK
| | - Katalin Lumniczky
- National Public Health Centre – National Research Institute for Radiobiology and Radiohygiene (NRIRR), Hungary
| | - Fiona Lyng
- Dublin Institute of Technology (DIT), Dublin, Ireland
| | - Ellina Macaeva
- Belgian Nuclear Research Centre (SCK-CEN), Mol, Belgium
- Ghent University (GU), Ghent, Belgium
| | | | - S. Vanda Martins
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico (IST/ITN), Universidade de Lisboa, Bobadela-LRS, Portugal
| | | | - Aidan Meade
- Dublin Institute of Technology (DIT), Dublin, Ireland
| | | | | | - Radhia M’kacher
- PROCyTOX, Commissariat à l’Energie Atomique et aux Energies Alternatives, Université Paris-Saclay (CEA), Fontenay-aux-Roses, France
| | - Octávia Monteiro Gil
- Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico (IST/ITN), Universidade de Lisboa, Bobadela-LRS, Portugal
| | - Alegria Montero
- Radiation Protection Service, IIS La Fe, Health Research Institute (LAFE), Spain
| | - Mercedes Moreno
- Laboratorio de Dosimetría Biológica, Servicio de Oncología Radioterápica, Hospital General Universitario Gregorio Marañón (SERMAS), Spain
| | | | - Ursula Oestreicher
- Bundesamt fuer Strahlenschutz (BfS), Department Radiation Protection and Health, Neuherberg, Germany
| | - Dominik Oskamp
- Radiation Biology Unit Forschungszentrum Jülich GmbH (FzJ), Jülich, Germany
| | | | - Valentina Palma
- Laboratory of Biosafety and Risk Assessment Division of Health Protection Technologies (ENEA) Casaccia Research Center, Italy
| | - Gabriel Pantelias
- Laboratory of Health Physics, Radiobiology & Cytogenetics Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety National Center for Scientific Research “Demokritos” (NCSRD), Greece
| | - Jerome Pateux
- Institut de Recherche Biomédicale des Armées (IRBA), Paris, France
| | - Clarice Patrono
- Laboratory of Biosafety and Risk Assessment Division of Health Protection Technologies (ENEA) Casaccia Research Center, Italy
| | - Gaetano Pepe
- Università degli Studi della Tuscia (UNITUS), Italy
| | - Matthias Port
- Bundeswehr Institute of Radiobiology (BIR), Munich, Germany
| | - María Jesús Prieto
- Laboratorio de Dosimetría Biológica, Servicio de Oncología Radioterápica, Hospital General Universitario Gregorio Marañón (SERMAS), Spain
| | | | - Roel Quintens
- Belgian Nuclear Research Centre (SCK-CEN), Mol, Belgium
| | - Michelle Ricoul
- PROCyTOX, Commissariat à l’Energie Atomique et aux Energies Alternatives, Université Paris-Saclay (CEA), Fontenay-aux-Roses, France
| | - Laurence Roy
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Paris, France
| | - Laure Sabatier
- PROCyTOX, Commissariat à l’Energie Atomique et aux Energies Alternatives, Université Paris-Saclay (CEA), Fontenay-aux-Roses, France
| | - Natividad Sebastià
- Radiation Protection Service, IIS La Fe, Health Research Institute (LAFE), Spain
| | | | - Sylwester Sommer
- Institute of Nuclear Chemistry and Technology (INCT), Warsaw, Poland
| | - Albena Staynova
- National Center of Radiobiology and Radiation Protection (NCRRP), Bulgaria
| | - Sonja Strunz
- Leibniz Institute for Farm Animal Biology (FBN), Dummerstorf, Germany
| | - Georgia Terzoudi
- Laboratory of Health Physics, Radiobiology & Cytogenetics Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety National Center for Scientific Research “Demokritos” (NCSRD), Greece
| | - Antonella Testa
- Laboratory of Biosafety and Risk Assessment Division of Health Protection Technologies (ENEA) Casaccia Research Center, Italy
| | - Francois Trompier
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Paris, France
| | - Marco Valente
- Institut de Recherche Biomédicale des Armées (IRBA), Paris, France
| | | | - Ivan Veronese
- Università degli Studi di Milano (UNIMI), Milano, Italy
| | | | - Clemens Woda
- Helmholtz Zentrum München (HMGU), Neuherberg, Germany
| |
Collapse
|
47
|
VRAL ANNE, DECORTE VEERLE, DEPUYDT JULIE, WAMBERSIE ANDRÉ, THIERENS HUBERT. A semi‑automated FISH‑based micronucleus‑centromere assay for biomonitoring of hospital workers exposed to low doses of ionizing radiation. Mol Med Rep 2016; 14:103-10. [PMID: 27176451 PMCID: PMC4918626 DOI: 10.3892/mmr.2016.5265] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2015] [Accepted: 03/10/2016] [Indexed: 12/02/2022] Open
Abstract
The aim of the present study was to perform cytogenetic analysis by means of a semi‑automated micronucleus‑centromere assay in lymphocytes from medical radiation workers. Two groups of workers receiving the highest occupational doses were selected: 10 nuclear medicine technicians and 10 interventional radiologists/cardiologists. Centromere‑negative micronucleus (MNCM‑) data, obtained from these two groups of medical radiation workers were compared with those obtained in matched controls. The blood samples of the matched controls were additionally used to construct a 'low‑dose' (0‑100 mGy) MNCM‑ dose‑response curve to evaluate the sensitivity and suitability of the micronucleus‑centromere assay as an 'effect' biomarker in medical surveillance programs. The physical dosimetry data of the 3 years preceding the blood sampling, based on single or double dosimetry practices, were collected for the interpretation of the micronucleus data. The in vitro radiation results showed that for small sized groups, semi‑automated scoring of MNCM‑ enables the detection of a dose of 50 mGy. The comparison of MNCM‑ yields in medical radiation workers and control individuals showed enhanced MNCM‑ scores in the medical radiation workers group (P=0.15). The highest MNCM‑ scores were obtained in the interventional radiologists/cardiologists group, and these scores were significantly higher compared with those obtained from the matched control group (P=0.05). The higher MNCM‑ scores observed in interventional radiologists/cardiologists compared with nuclear medicine technicians were not in agreement with the personal dosimetry records in both groups, which may point to the limitation of 'double dosimetry' procedures used in interventional radiology/cardiology. In conclusion, the data obtained in the present study supports the importance of cytogenetic analysis, in addition to physical dosimetry, as a routine biomonitoring method in medical radiation workers receiving the highest occupational radiation burdens.
Collapse
Affiliation(s)
- ANNE VRAL
- Department of Basic Medical Sciences, Ghent University, B-9000 Ghent, Belgium
| | - VEERLE DECORTE
- Scientific Committee Centre de Services Interentreprises, External Service For Prevention and Protection at Work, Catholic University of Louvain, St-Luc Clinical University, B-1200 Brussels, Belgium
| | - JULIE DEPUYDT
- Department of Basic Medical Sciences, Ghent University, B-9000 Ghent, Belgium
| | - ANDRÉ WAMBERSIE
- Institute of Experimental and Clinical Research, Molecular Imaging, Radiotherapy and Oncology Unit, Catholic University of Louvain, St-Luc Clinical University, B-1200 Brussels, Belgium
| | - HUBERT THIERENS
- Department of Basic Medical Sciences, Ghent University, B-9000 Ghent, Belgium
| |
Collapse
|
48
|
Rühm W, Fantuzzi E, Harrison R, Schuhmacher H, Vanhavere F, Alves J, Bottollier Depois JF, Fattibene P, Knežević Ž, Lopez MA, Mayer S, Miljanić S, Neumaier S, Olko P, Stadtmann H, Tanner R, Woda C. EURADOS strategic research agenda: vision for dosimetry of ionising radiation. RADIATION PROTECTION DOSIMETRY 2016; 168:223-34. [PMID: 25752758 PMCID: PMC4884873 DOI: 10.1093/rpd/ncv018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Revised: 02/05/2015] [Accepted: 02/06/2015] [Indexed: 05/04/2023]
Abstract
Since autumn 2012, the European Radiation Dosimetry Group (EURADOS) has been developing its Strategic Research Agenda (SRA), which is intended to contribute to the identification of future research needs in radiation dosimetry in Europe. The present article summarises-based on input from EURADOS Working Groups (WGs) and Voting Members-five visions in dosimetry and defines key issues in dosimetry research that are considered important for the next decades. The five visions include scientific developments required towards (a) updated fundamental dose concepts and quantities, (b) improved radiation risk estimates deduced from epidemiological cohorts, (c) efficient dose assessment for radiological emergencies, (d) integrated personalised dosimetry in medical applications and (e) improved radiation protection of workers and the public. The SRA of EURADOS will be used as a guideline for future activities of the EURADOS WGs. A detailed version of the SRA can be downloaded as a EURADOS report from the EURADOS website (www.eurados.org).
Collapse
Affiliation(s)
- W Rühm
- Helmholtz Center Munich, Institute of Radiation Protection, Neuherberg, Germany
| | - E Fantuzzi
- Radiation Protection Institute, ENEA, Bologna, Italy
| | | | - H Schuhmacher
- Physikalisch Technische Bundesanstalt (PTB), Braunschweig, Germany
| | - F Vanhavere
- Belgian Nuclear Research Centre (SCK-CEN), Mol, Belgium
| | - J Alves
- Instituto Superior Técnico (IST), CTN, Lisboa, Portugal
| | - J F Bottollier Depois
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Fontenay-aux-Roses Cedex, France
| | - P Fattibene
- Istituto Superiore di Sanità (ISS), Rome, Italy
| | - Ž Knežević
- Ruđer Bošković Institute (RBI), Zagreb, Croatia
| | - M A Lopez
- Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Madrid, Spain
| | - S Mayer
- Paul Scherer Institut (PSI), Villigen, Switzerland
| | - S Miljanić
- Ruđer Bošković Institute (RBI), Zagreb, Croatia
| | - S Neumaier
- Physikalisch Technische Bundesanstalt (PTB), Braunschweig, Germany
| | - P Olko
- Instytut Fizyki Jądrowej (IFJ), Krakow, Poland
| | - H Stadtmann
- Seibersdorf Labor GmbH, Seibersdorf, Austria
| | - R Tanner
- Public Health England, Chilton, Didcot, UK
| | - C Woda
- Helmholtz Center Munich, Institute of Radiation Protection, Neuherberg, Germany
| |
Collapse
|
49
|
Oliveira M, Einbeck J, Higueras M, Ainsbury E, Puig P, Rothkamm K. Zero-inflated regression models for radiation-induced chromosome aberration data: A comparative study. Biom J 2015; 58:259-79. [PMID: 26461836 DOI: 10.1002/bimj.201400233] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2014] [Revised: 07/29/2015] [Accepted: 08/03/2015] [Indexed: 11/11/2022]
Abstract
Within the field of cytogenetic biodosimetry, Poisson regression is the classical approach for modeling the number of chromosome aberrations as a function of radiation dose. However, it is common to find data that exhibit overdispersion. In practice, the assumption of equidispersion may be violated due to unobserved heterogeneity in the cell population, which will render the variance of observed aberration counts larger than their mean, and/or the frequency of zero counts greater than expected for the Poisson distribution. This phenomenon is observable for both full- and partial-body exposure, but more pronounced for the latter. In this work, different methodologies for analyzing cytogenetic chromosomal aberrations datasets are compared, with special focus on zero-inflated Poisson and zero-inflated negative binomial models. A score test for testing for zero inflation in Poisson regression models under the identity link is also developed.
Collapse
Affiliation(s)
- María Oliveira
- Department of Mathematical Sciences, Durham University, Durham DH1 3LE, UK
| | - Jochen Einbeck
- Department of Mathematical Sciences, Durham University, Durham DH1 3LE, UK
| | - Manuel Higueras
- Centre for Radiation, Chemical and Environmental Hazards (CRCE), Public Health England, Chilton, Didcot, Oxon OX11 0RQ, UK.,Departament de Matematiques, Universitat Autonoma de Barcelona, Bellaterra (Barcelona) 08193, Spain
| | - Elizabeth Ainsbury
- Centre for Radiation, Chemical and Environmental Hazards (CRCE), Public Health England, Chilton, Didcot, Oxon OX11 0RQ, UK
| | - Pedro Puig
- Departament de Matematiques, Universitat Autonoma de Barcelona, Bellaterra (Barcelona) 08193, Spain
| | - Kai Rothkamm
- Centre for Radiation, Chemical and Environmental Hazards (CRCE), Public Health England, Chilton, Didcot, Oxon OX11 0RQ, UK.,Department of Radiotherapy & Radio-Oncology, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany
| |
Collapse
|
50
|
Lue SW, Repin M, Mahnke R, Brenner DJ. Development of a High-Throughput and Miniaturized Cytokinesis-Block Micronucleus Assay for Use as a Biological Dosimetry Population Triage Tool. Radiat Res 2015; 184:134-42. [PMID: 26230078 DOI: 10.1667/rr13991.1] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Biodosimetry is an essential tool for providing timely assessments of radiation exposure. For a large mass-casualty event involving exposure to ionizing radiation, it is of utmost importance to rapidly provide dose information for medical treatment. The well-established cytokinesis-block micronucleus (CBMN) assay is a validated method for biodosimetry. However, the need for an accelerated sample processing is required for the CBMN assay to be a suitable population triage tool. We report here on the development of a high-throughput and miniaturized version of the CMBN assay for accelerated sample processing.
Collapse
Affiliation(s)
- Stanley W Lue
- a Center for Radiological Research, Department of Radiation Oncology, Columbia University Medical Center, New York, New York 10032; and
| | - Mikhail Repin
- a Center for Radiological Research, Department of Radiation Oncology, Columbia University Medical Center, New York, New York 10032; and
| | - Ryan Mahnke
- b Northrop Grumman, Elkridge, Maryland 21075
| | - David J Brenner
- a Center for Radiological Research, Department of Radiation Oncology, Columbia University Medical Center, New York, New York 10032; and
| |
Collapse
|