57201
|
Childs WR, Nuzzo RG. Decal transfer microlithography: a new soft-lithographic patterning method. J Am Chem Soc 2002; 124:13583-96. [PMID: 12418914 DOI: 10.1021/ja020942z] [Citation(s) in RCA: 74] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A new soft-lithographic method for micropatterning polymeric resists, Decal Transfer Microlithography (DTM), is described. This technique is based on the transfer of elastomeric decal patterns via the engineered adhesion and release properties of a compliant poly(dimethylsiloxane) (PDMS) patterning tool. An important feature of the DTM method is the exceptionally broad spectrum of design rules that it embraces. This procedure is capable of transferring micron to submicron-sized features with high fidelity over large substrate areas and potentially simplifies to a significant degree the requirements for effecting multiple levels of registration. The DTM method offers some potential advantages over other soft-lithographic patterning methods in that it is amenable to transferring resist patterns with both open and closed forms, negative and positive image contrasts, and does so for a wide variety of aspect ratios and a significant range of pattern pitches that can be accommodated without degradation due to mechanical distortions of the pattern transfer tool. The most significant advance embodied in the DTM method, however, is that it offers useful new capabilities for the design and fabrication of advanced planar and 3D microfluidic assemblies and microreactors.
Collapse
Affiliation(s)
- William R Childs
- School of Chemical Sciences, Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, 61801, USA
| | | |
Collapse
|
57202
|
Dinsmore AD, Hsu MF, Nikolaides MG, Marquez M, Bausch AR, Weitz DA. Colloidosomes: selectively permeable capsules composed of colloidal particles. Science 2002; 298:1006-9. [PMID: 12411700 DOI: 10.1126/science.1074868] [Citation(s) in RCA: 1342] [Impact Index Per Article: 58.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
We present an approach to fabricate solid capsules with precise control of size, permeability, mechanical strength, and compatibility. The capsules are fabricated by the self-assembly of colloidal particles onto the interface of emulsion droplets. After the particles are locked together to form elastic shells, the emulsion droplets are transferred to a fresh continuous-phase fluid that is the same as that inside the droplets. The resultant structures, which we call "colloidosomes," are hollow, elastic shells whose permeability and elasticity can be precisely controlled. The generality and robustness of these structures and their potential for cellular immunoisolation are demonstrated by the use of a variety of solvents, particles, and contents.
Collapse
Affiliation(s)
- A D Dinsmore
- Department of Physics and DEAS, Harvard University, Cambridge, MA 02138, USA.
| | | | | | | | | | | |
Collapse
|
57203
|
Abstract
Light damage to the retina occurs through three general mechanisms involving thermal, mechanical, or photochemical effects. The particular mechanism activated depends on the wavelength and exposure duration of the injuring light. The transitions between the various light damage mechanism may overlap to some extent. Energy confinement is a key concept in understanding or predicting the type of damage mechanism produced by a given light exposure. As light energy (either from a laser or an incoherent source) is deposited in the retina, its penetration through, and its absorption in, various tissue compartments is determined by its wavelength. Strongly absorbing tissue components will tend to "concentrate" the light energy. The effect of absorbed light energy largely depends on the rate of energy deposition, which is correlated with the exposure duration. If the rate of energy deposition is too low to produce an appreciable temperature increase in the tissue, then any resulting tissue damage necessarily occurs because of chemical (oxidative) reactions induced by absorption of energetic photons (photochemical damage). If the rate of energy deposition is faster than the rate of thermal diffusion (thermal confinement), then the temperature of the exposed tissue rises. If a critical temperature is reached (typically about 10 degrees C above basal), then thermal damage occurs. If the light energy is deposited faster than mechanical relaxation can occur (stress confinement), then a thermoelastic pressure wave is produced, and tissue is disrupted by shear forces or by cavitation-nonlinear effects. Very recent evidence suggests that ultrashort laser pulses can produce tissue damage through nonlinear and photochemical mechanisms; the latter because of two-photon excitation of cellular chromophores. In addition to tissue damage caused directly by light absorption, light toxicity can be produced by the presence of photosensitizing agents. Drugs excited to reactive states by ultraviolet (UV) or visible light produce damage by type I (free radical) and type II (oxygen dependent) mechanisms. Some commonly used drugs, such as certain antibiotics, nonsteroidal anti-inflammatory drugs (NSAIDs), and psychotherapeutic agents, as well as some popular herbal medicines, can produce ocular phototoxicity. Specific cellular effects and damage end points characteristic of light damage mechanisms are described.
Collapse
Affiliation(s)
- Randolph D Glickman
- Department of Ophthalmology, University of Texas Health Science Center, San Antonio, Texas 78229-3900, USA.
| |
Collapse
|
57204
|
Affiliation(s)
- Elena Rabkin
- Department of Pathology, Brigham and Women's Hospital, Boston, MA 02115, USA
| | | |
Collapse
|
57205
|
Borsi L, Balza E, Bestagno M, Castellani P, Carnemolla B, Biro A, Leprini A, Sepulveda J, Burrone O, Neri D, Zardi L. Selective targeting of tumoral vasculature: comparison of different formats of an antibody (L19) to the ED-B domain of fibronectin. Int J Cancer 2002; 102:75-85. [PMID: 12353237 DOI: 10.1002/ijc.10662] [Citation(s) in RCA: 270] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
We recently demonstrated that a human recombinant scFv, L19, reacting with the ED-B domain of fibronectin, a marker of angiogenesis, selectively targets tumoral vasculature in vivo. Using the variable regions of L19, we constructed and expressed a human "small immunoprotein" (SIP) and a complete human IgG1 and performed biodistribution studies in tumor-bearing mice to compare the blood clearance rate, in vivo stability and performance in tumor targeting of the 3 L19 formats [dimeric scFv (scFv)(2), SIP and IgG1]. The accumulation of the different antibody formats in the tumors studied was a consequence of the clearance rate and in vivo stability of the molecules. Using the SIP, the %ID/g in tumors was 2-5 times higher than that of the (scFv)(2), reaching a maximum 4-6 hr after injection. By contrast, the accumulation of IgG1 in tumors constantly rose during the experiments. However, due to its slow clearance, the tumor-blood ratio of the %ID/g after 144 hr was only about 3 compared to a ratio of 10 for the (scFv)(2) and 70 for the SIP after the same period of time. The different in vivo behavior of these 3 completely human L19 formats could be exploited for different diagnostic and/or therapeutic purposes, depending on clinical needs and disease. Furthermore, the fact that ED-B is 100% homologous in human and mouse, which ensures that L19 reacts equally well with the human and the murine antigen, should expedite the transfer of these reagents to clinical trials.
Collapse
Affiliation(s)
- Laura Borsi
- Laboratory of Cell Biology, Istituto Nazionale per la Ricerca sul Cancro, Genoa, Italy
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
57206
|
Tamura A, Omori K, Miki K, Lee JB, Yang KH, King AI. Mechanical characterization of porcine abdominal organs. STAPP CAR CRASH JOURNAL 2002; 46:55-69. [PMID: 17096218 DOI: 10.4271/2002-22-0003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Typical automotive related abdominal injuries occur due to contact with the rim of the steering wheel, seatbelt and armrest, however, the rate is less than in other body regions. When solid abdominal organs, such as the liver, kidneys and spleen are involved, the injury severity tends to be higher. Although sled and pendulum impact tests have been conducted using cadavers and animals, the mechanical properties and the tissue level injury tolerance of abdominal solid organs are not well characterized. These data are needed in the development of computer models, the improvement of current anthropometric test devices and the enhancement of our understanding of abdominal injury mechanisms. In this study, a series of experimental tests on solid abdominal organs was conducted using porcine liver, kidney and spleen specimens. Additionally, the injury tolerance of the solid organs was deduced from the experimental data.
Collapse
|
57207
|
Klymchenko AS, Duportail G, Ozturk T, Pivovarenko VG, Mély Y, Demchenko AP. Novel two-band ratiometric fluorescence probes with different location and orientation in phospholipid membranes. CHEMISTRY & BIOLOGY 2002; 9:1199-208. [PMID: 12445770 DOI: 10.1016/s1074-5521(02)00244-2] [Citation(s) in RCA: 127] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
3-hydroxyflavone (3-HF) derivatives are very attractive fluorescence sensors due to their ability to respond to small changes in their microenvironment via a dramatic alteration of the relative intensities of their two well-separated emission bands. We developed fluorescence probes with locations at different depths and orientations of 3-HF moiety in the phospholipid bilayer, which determine their fluorescence behavior. While the spectral shifts of the probes correlate with their binding site polarity, the intensity ratio is a complex parameter that is also sensitive to the local hydration. We demonstrate that even the deeply located probes sense this hydration effect, which can be modulated by the charge of the lipid heads and is anisotropic with respect to the bilayer plane. Thus the two-band ratiometric fluorescence probes can provide multiparametric information on the properties of lipid membranes at different depths.
Collapse
Affiliation(s)
- Andrey S Klymchenko
- TUBITAK Research Institute for Genetic Engineering and Biotechnology, Gebze-Kocaeli 41470, Turkey
| | | | | | | | | | | |
Collapse
|
57208
|
Donoghue JP. Connecting cortex to machines: recent advances in brain interfaces. Nat Neurosci 2002; 5 Suppl:1085-8. [PMID: 12403992 DOI: 10.1038/nn947] [Citation(s) in RCA: 341] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2002] [Accepted: 09/16/2002] [Indexed: 11/08/2022]
Abstract
Recent technological and scientific advances have generated wide interest in the possibility of creating a brain-machine interface (BMI), particularly as a means to aid paralyzed humans in communication. Advances have been made in detecting neural signals and translating them into command signals that can control devices. We now have systems that use externally derived neural signals as a command source, and faster and potentially more flexible systems that directly use intracortical recording are being tested. Studies in behaving monkeys show that neural output from the motor cortex can be used to control computer cursors almost as effectively as a natural hand would carry out the task. Additional research findings explore the possibility of using computers to return behaviorally useful feedback information to the cortex. Although significant scientific and technological challenges remain, progress in creating useful human BMIs is accelerating.
Collapse
Affiliation(s)
- John P Donoghue
- Department of Neuroscience, Box 1953, Brown University, Providence, Rhode Island 02912, USA.
| |
Collapse
|
57209
|
Chan AH, Fujimoto VY, Moore DE, Martin RW, Vaezy S. An image-guided high intensity focused ultrasound device for uterine fibroids treatment. Med Phys 2002; 29:2611-20. [PMID: 12462728 DOI: 10.1118/1.1513990] [Citation(s) in RCA: 78] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
A high intensity focused ultrasound (HIFU) device was developed for treating uterine fibroid tumors. This prototype device enables image-guided therapy by aligning a commercially available abdominal ultrasound image probe to a vaginal HIFU transducer so the HIFU focus is in the image plane. The device was designed based on anatomical constraints of the female pelvic structures. HIFU was generated using a 3.5 MHz PZT-8 crystal, 25.4 mm in diameter, bonded to an aluminum lens. Computer simulations were performed to ensure that effective focusing was achievable at a fixed focal depth of 40 mm. Transducer efficiency was empirically determined to be 58%, and the half pressure maximum focal dimensions were 11 mm in length and 1.2 mm in width. A water-filled latex condom surrounding the transducer provided acoustic coupling, a stand-off, and allowed water circulation for transducer cooling. In vitro experiments in a tissue-mimicking gel phantom and in turkey breast demonstrated ultrasound image-guided lesion formation, or tissue necrosis, at the focus due to HIFU induced thermal and cavitation effects. The HIFU treatment site appeared as a hyperechoic spot on the ultrasound image at intensities above 1250 W/cm2. The results of in vitro experiments and in vivo ergonomic testing in six human volunteers indicated that the device has the potential of providing a nonsurgical approach for uterine fibroid treatment. Future in vivo studies in large animal models and fibroids patients are planned.
Collapse
Affiliation(s)
- Arthur H Chan
- Department of Bioengineering, University of Washington, Seattle, Washington 98105, USA.
| | | | | | | | | |
Collapse
|
57210
|
Kovacevic N, Lobaugh NJ, Bronskill MJ, Levine B, Feinstein A, Black SE. A robust method for extraction and automatic segmentation of brain images. Neuroimage 2002; 17:1087-100. [PMID: 12414252 DOI: 10.1006/nimg.2002.1221] [Citation(s) in RCA: 96] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
A new protocol is introduced for brain extraction and automatic tissue segmentation of MR images. For the brain extraction algorithm, proton density and T2-weighted images are used to generate a brain mask encompassing the full intracranial cavity. Segmentation of brain tissues into gray matter (GM), white matter (WM), and cerebral spinal fluid (CSF) is accomplished on a T1-weighted image after applying the brain mask. The fully automatic segmentation algorithm is histogram-based and uses the Expectation Maximization algorithm to model a four-Gaussian mixture for both global and local histograms. The means of the local Gaussians for GM, WM, and CSF are used to set local thresholds for tissue classification. Reproducibility of the extraction procedure was excellent, with average variation in intracranial capacity (TIC) of 0.13 and 0.66% TIC in 12 healthy normal and 33 Alzheimer brains, respectively. Repeatability of the segmentation algorithm, tested on healthy normal images, indicated scan-rescan differences in global tissue volumes of less than 0.30% TIC. Reproducibility at the regional level was established by comparing segmentation results within the 12 major Talairach subdivisions. Accuracy of the algorithm was tested on a digital brain phantom, and errors were less than 1% of the phantom volume. Maximal Type I and Type II classification errors were low, ranging between 2.2 and 4.3% of phantom volume. The algorithm was also insensitive to variation in parameter initialization values. The protocol is robust, fast, and its success in segmenting normal as well as diseased brains makes it an attractive clinical application.
Collapse
Affiliation(s)
- N Kovacevic
- Sunnybrook and Women's College Health Sciences Centre, Toronto, Ontario, Canada
| | | | | | | | | | | |
Collapse
|
57211
|
Kowalski ME, Behnia B, Webb AG, Jin JM. Optimization of electromagnetic phased-arrays for hyperthermia via magnetic resonance temperature estimation. IEEE Trans Biomed Eng 2002; 49:1229-41. [PMID: 12450353 DOI: 10.1109/tbme.2002.804602] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A technique for the optimization of electromagnetic annular phased arrays (APAs) for therapeutic hyperthermia has been developed and implemented. The controllable inputs are the amplitudes and phases of the driving signals of each element of the array. Magnetic resonance imaging (MRI) is used to estimate noninvasively the temperature distribution based on the temperature dependence of the proton resonance frequency (PRF). A parametric model of the dynamics that couple the control inputs to the resultant temperature elevations is developed based on physical considerations. The unknown parameters of this model are estimated during a pretreatment identification phase and can be continuously updated as new measurement data become available. Based on the parametric model, a controller automatically chooses optimal phases and amplitudes of the driving signals of the APA. An advantage of this approach to optimizing the APA is that no a priori information is required, eliminating the need for patient-specific computational modeling and optimization. Additionally, this approach represents a first step toward employing temperature feedback to make the optimization of the APA robust with respect to modeling errors and physiological changes. The ability of the controller to choose therapeutically beneficial driving amplitudes and phases is demonstrated via simulation. Experimental results are presented which demonstrate the ability of the controller to choose optimal phases for the APA using only information from magnetic resonance thermometry (MRT).
Collapse
Affiliation(s)
- Marc E Kowalski
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801-2991, USA.
| | | | | | | |
Collapse
|
57212
|
Lewis JS, Achilefu S, Garbow JR, Laforest R, Welch MJ. Small animal imaging. current technology and perspectives for oncological imaging. Eur J Cancer 2002; 38:2173-88. [PMID: 12387842 DOI: 10.1016/s0959-8049(02)00394-5] [Citation(s) in RCA: 100] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Advances in the biomedical sciences have been accelerated by the introduction of many new imaging technologies in recent years. With animal models widely used in the basic and pre-clinical sciences, finding ways to conduct animal experiments more accurately and efficiently becomes a key factor in the success and timeliness of research. Non-invasive imaging technologies prove to be extremely valuable tools in performing such studies and have created the recent surge in small animal imaging. This review is focused on three modalities, PET, MR and optical imaging which are available to the scientist for oncological investigations in animals.
Collapse
Affiliation(s)
- Jason S Lewis
- Radiation Sciences, Washington University School of Medicine, Saint Louis, MO, USA
| | | | | | | | | |
Collapse
|
57213
|
Natt O, Watanabe T, Boretius S, Radulovic J, Frahm J, Michaelis T. High-resolution 3D MRI of mouse brain reveals small cerebral structures in vivo. J Neurosci Methods 2002; 120:203-9. [PMID: 12385770 DOI: 10.1016/s0165-0270(02)00211-x] [Citation(s) in RCA: 101] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
This work demonstrates technical approaches to high-quality magnetic resonance imaging (MRI) of small structures of the mouse brain in vivo. It turns out that excellent soft-tissue contrast requires the reduction of partial volume effects by using 3D MRI at high (isotropic) resolution with linear voxel dimensions of about 100-150 microm. The long T(2)* relaxation times at relatively low magnetic fields (2.35 T) offer the benefit of a small receiver bandwidth (increased signal-to-noise) at a moderate echo time which together with the small voxel size avoids visual susceptibility artifacts. For measuring times of 1-1.5 h both T(1)-weighted (FLASH) and T(2)-weighted (Fast Spin-Echo) 3D MRI acquisitions exhibit detailed anatomical insights in accordance with histological sections from a mouse brain atlas. Preliminary applications address the identification of neuroanatomical variations in different mouse strains and the use of Mn(2+) as a T(1) contrast agent for neuroaxonal tracing of fiber tracts within the mouse visual pathway.
Collapse
Affiliation(s)
- O Natt
- Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für biophysikalische Chemie, 37070 Göttingen, Germany
| | | | | | | | | | | |
Collapse
|
57214
|
Abstract
To advance our understanding of biological processes as they occur in living animals, imaging strategies have been developed and refined that reveal cellular and molecular features of biology and disease in real time. One rapid and accessible technology for in vivo analysis employs internal biological sources of light emitted from luminescent enzymes, luciferases, to label genes and cells. Combining this reporter system with the new generation of charge coupled device (CCD) cameras that detect the light transmitted through the animal's tissues has opened the door to sensitive in vivo measurements of mammalian gene expression in living animals. Here, we review the development and application of this imaging strategy, in vivo bioluminescence imaging (BLI), together with in vivo fluorescence imaging methods, which has enabled the real-time study of immune cell trafficking, of various genetic regulatory elements in transgenic mice, and of in vivo gene transfer. BLI has been combined with fluorescence methods that together offer access to in vivo measurements that were not previously available. Such studies will greatly facilitate the functional analysis of a wide range of genes for their roles in health and disease.
Collapse
Affiliation(s)
- Christopher H Contag
- Department of Pediatrics, Stanford University School of Medicine, California 94305-5208, USA.
| | | |
Collapse
|
57215
|
Abstract
Proteomics is a rapidly emerging set of key technologies that are being used to identify proteins and map their interactions in a cellular context. With the sequencing of the human genome, the scope of proteomics has shifted from protein identification and characterization to include protein structure, function and protein-protein interactions. Technologies used in proteomic research include two-dimensional gel electrophoresis, mass spectrometry, yeast two-hybrids screens, and computational prediction programs. While some of these technologies have been in use for a long time, they are currently being applied to study physiology and cellular processes in high-throughput formats. It is the high-throughput approach that defines and characterizes modern proteomics. In this review, we discuss the current status of these experimental and computational technologies relevant to the three major aspects of proteomics-characterization of proteomes, identification of proteins, and determination of protein function. We also briefly discuss the development of new proteomic technologies that are based on recent advances in analytical and biochemical techniques, engineering, microfabrication, and computational prowess. The integration of these advances with established technologies is invaluable for the drive toward a comprehensive understanding of protein structure and function in the cellular milieu.
Collapse
MESH Headings
- Electrophoresis, Gel, Two-Dimensional/instrumentation
- Electrophoresis, Gel, Two-Dimensional/methods
- Electrophoresis, Gel, Two-Dimensional/trends
- Gene Expression Profiling/instrumentation
- Gene Expression Profiling/methods
- Gene Expression Profiling/trends
- Protein Interaction Mapping/instrumentation
- Protein Interaction Mapping/methods
- Proteome/chemistry
- Proteome/genetics
- Proteome/physiology
- Sensitivity and Specificity
- Sequence Analysis, Protein/instrumentation
- Sequence Analysis, Protein/methods
- Sequence Analysis, Protein/trends
- Spectrometry, Mass, Electrospray Ionization/instrumentation
- Spectrometry, Mass, Electrospray Ionization/methods
- Spectrometry, Mass, Electrospray Ionization/trends
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/trends
Collapse
Affiliation(s)
- Martin L Yarmush
- Center for Engineering in Medicine/Surgical Services, Massachusetts General Hospital, Harvard Medical School, Boston 02114, USA.
| | | |
Collapse
|
57216
|
Abstract
This paper reviews literature, current concepts and approaches in computational anatomy (CA). The model of CA is a Grenander deformable template, an orbit generated from a template under groups of diffeomorphisms. The metric space of all anatomical images is constructed from the geodesic connecting one anatomical structure to another in the orbit. The variational problems specifying these metrics are reviewed along with their associated Euler-Lagrange equations. The Euler equations of motion derived by Arnold for the geodesics in the group of divergence-free volume-preserving diffeomorphisms of incompressible fluids are generalized for the larger group of diffeomorphisms used in CA with nonconstant Jacobians. Metrics that accommodate photometric variation are described extending the anatomical model to incorporate the construction of neoplasm. Metrics on landmarked shapes are reviewed as well as Joshi's diffeomorphism metrics, Bookstein's thin-plate spline approximate-metrics, and Kendall's affine invariant metrics. We conclude by showing recent experimental results from the Toga & Thompson group in growth, the Van Essen group in macaque and human cortex mapping, and the Csernansky group in hippocampus mapping for neuropsychiatric studies in aging and schizophrenia.
Collapse
Affiliation(s)
- Michael I Miller
- Center for Imaging Science, The Johns Hopkins University, Baltimore, Maryland 21218, USA.
| | | | | |
Collapse
|
57217
|
Abstract
Fluid flow at the microscale exhibits unique phenomena that can be leveraged to fabricate devices and components capable of performing functions useful for biological studies. The physics of importance to microfluidics are reviewed. Common methods of fabricating microfluidic devices and systems are described. Components, including valves, mixers, and pumps, capable of controlling fluid flow by utilizing the physics of the microscale are presented. Techniques for sensing flow characteristics are described and examples of devices and systems that perform bioanalysis are presented. The focus of this review is microscale phenomena and the use of the physics of the scale to create devices and systems that provide functionality useful to the life sciences.
Collapse
Affiliation(s)
- David J Beebe
- Department of Biomedical Engineering, University of Wisconsin, Madison 53706, USA.
| | | | | |
Collapse
|
57218
|
Abstract
Magnetic resonance imaging (MRI) provides a noninvasive way to evaluate the biomechanical dynamics of the heart. MRI can provide spatially registered tomographic images of the heart in different phases of the cardiac cycle, which can be used to assess global cardiac function and regional endocardial surface motion. In addition, MRI can provide detailed information on the patterns of motion within the heart wall, permitting calculation of the evolution of regional strain and related motion variables within the wall. These show consistent patterns of spatial and temporal variation in normal subjects, which are affected by alterations of function due to disease. Although still an evolving technique, MRI shows promise as a new method for research and clinical evaluation of cardiac dynamics.
Collapse
Affiliation(s)
- Leon Axel
- Department of Radiology, University of Pennsylvania, Philadelphia 19104, USA.
| |
Collapse
|
57219
|
Abstract
The field of clinical rehabilitation is rooted in the premise that carefully planned and delivered therapeutic intervention enhances patient outcomes. Underlying this statement is a deeper scientific reality: The field exists because biosystems (e.g., tissues, cells, organs, persons) are inherently adaptive and can dynamically change as a function of a sequence of inputs (e.g., exercise, pharmaceuticals). The tools of telerehabilitation help minimize the barrier of distance, both of patients to rehabilitative services and of researchers to subject populations. This enhanced access opens up new possibilities for discovering and implementing optimized intervention strategies across the continuum of care. Telecommunications technologies are reviewed from the perspective of systems models of the telerehabilitation process, with a focus on human-technology interface design and a special emphasis on emerging home and mobile technologies. Approaches for providing clinical rehabilitation services through telerehabilitation are addressed, including innovative consumer-centered approaches. Finally, telerehabilitation is proposed as a tool for reinvigorating the rehabilitative bioengineering research enterprise.
Collapse
Affiliation(s)
- Jack M Winters
- Department of Biomedical Engineering, Marquette University, Milwaukee, Wisconsin 53201-1881, USA.
| |
Collapse
|
57220
|
Chilkoti A, Dreher MR, Meyer DE. Design of thermally responsive, recombinant polypeptide carriers for targeted drug delivery. Adv Drug Deliv Rev 2002; 54:1093-111. [PMID: 12384309 DOI: 10.1016/s0169-409x(02)00060-1] [Citation(s) in RCA: 198] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
In this article, we review recombinant DNA methods for the design and synthesis of amino acid-based biopolymers, and briefly summarize an approach, recursive directional ligation (RDL), that we have employed to synthesize oligomeric genes for such biopolymers. We then describe our ongoing research in the use of RDL to synthesize recombinant polypeptide carriers for the targeted delivery of radionuclides, chemotherapeutics and biomolecular therapeutics to tumors. The targeted delivery system uses a thermally responsive, elastin-like polypeptide (ELP) as the drug carrier to enhance the localization of ELP-drug conjugates within a solid tumor that is heated by regional hyperthermia. In the context of this drug delivery application, we discuss the design of ELPs and their recombinant synthesis, which enables the molecular weight and the thermal properties of the polypeptide to be precisely controlled. Finally, our results pertaining to the in vivo targeting of tumors with ELPs are briefly summarized.
Collapse
Affiliation(s)
- Ashutosh Chilkoti
- Department of Biomedical Engineering, Duke University, Durham, NC 27708-0281, USA.
| | | | | |
Collapse
|
57221
|
Zhang C, Shapiro AD. Two pathways act in an additive rather than obligatorily synergistic fashion to induce systemic acquired resistance and PR gene expression. BMC PLANT BIOLOGY 2002; 2:9. [PMID: 12381270 PMCID: PMC130961 DOI: 10.1186/1471-2229-2-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2002] [Accepted: 10/15/2002] [Indexed: 05/20/2023]
Abstract
BACKGROUND Local infection with necrotizing pathogens induces whole plant immunity to secondary challenge. Pathogenesis-related genes are induced in parallel with this systemic acquired resistance response and thought to be co-regulated. The hypothesis of co-regulation has been challenged by induction of Arabidopsis PR-1 but not systemic acquired resistance in npr1 mutant plants responding to Pseudomonas syringae carrying the avirulence gene avrRpt2. However, experiments with ndr1 mutant plants have revealed major differences between avirulence genes. The ndr1-1 mutation prevents hypersensitive cell death, systemic acquired resistance and PR-1 induction elicited by bacteria carrying avrRpt2. This mutation does not prevent these responses to bacteria carrying avrB. RESULTS Systemic acquired resistance, PR-1 induction and PR-5 induction were assessed in comparisons of npr1-2 and ndr1-1 mutant plants, double mutant plants, and wild-type plants. Systemic acquired resistance was displayed by all four plant lines in response to Pseudomonas syringae bacteria carrying avrB. PR-1 induction was partially impaired by either single mutation in response to either bacterial strain, but only fully impaired in the double mutant in response to avrRpt2. PR-5 induction was not fully impaired in any of the mutants in response to either avirulence gene. CONCLUSION Two pathways act additively, rather than in an obligatorily synergistic fashion, to induce systemic acquired resistance, PR-1 and PR-5. One of these pathways is NPR1-independent and depends on signals associated with hypersensitive cell death. The other pathway is dependent on salicylic acid accumulation and acts through NPR1. At least two other pathways also contribute additively to PR-5 induction.
Collapse
Affiliation(s)
- Chu Zhang
- Department of Plant and Soil Sciences, Delaware Agricultural Experiment Station, College of Agriculture and Natural Resources, University of Delaware, Newark, DE, USA
| | - Allan D Shapiro
- Department of Plant and Soil Sciences, Delaware Agricultural Experiment Station, College of Agriculture and Natural Resources, University of Delaware, Newark, DE, USA
| |
Collapse
|
57222
|
Balog RP, de Souza YEP, Tang HM, DeMasellis GM, Gao B, Avila A, Gaban DJ, Mittelman D, Minna JD, Luebke KJ, Garner HR. Parallel assessment of CpG methylation by two-color hybridization with oligonucleotide arrays. Anal Biochem 2002; 309:301-10. [PMID: 12413464 PMCID: PMC3484840 DOI: 10.1016/s0003-2697(02)00294-4] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
We have developed a method for the parallel analysis of multiple CpG sites in genomic DNA for their state of methylation. Hypermethylation of CpG islands within the promoters and 5' exons of genes has been found to be a mechanism of transcriptional inactivation associated with a variety of tumors. The method that we developed relies on the differential reactivity of methylated and unmethylated cytosines with sodium bisulfite, which exclusively converts unmethylated cytosines to deoxyuracils. The resulting sequence changes are determined with single-nucleotide resolution by hybridization to an oligonucleotide array. Cohybridization with a reference sample containing a different label provides an internal standard for assessment of methylation state. This method provides advantages in parallelism over existing methods of methylation analysis. We have demonstrated this technique with a region from the promoter of the tumor suppressor gene p16, which is hypermethylated in many cancers.
Collapse
Affiliation(s)
- Robert P. Balog
- Center for Biomedical Inventions, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8573, USA
- McDermott Center for Human Growth and Development, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8591, USA
| | - Y. Emi Ponce de Souza
- McDermott Center for Human Growth and Development, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8591, USA
| | - Hue M. Tang
- McDermott Center for Human Growth and Development, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8591, USA
| | - Gina M. DeMasellis
- McDermott Center for Human Growth and Development, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8591, USA
| | - Boning Gao
- The Hamon Center for Therapeutic Oncology Research, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8593, USA
| | - Adrian Avila
- The Hamon Center for Therapeutic Oncology Research, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8593, USA
| | - Desmond J. Gaban
- McDermott Center for Human Growth and Development, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8591, USA
| | - David Mittelman
- McDermott Center for Human Growth and Development, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8591, USA
| | - John D. Minna
- The Hamon Center for Therapeutic Oncology Research, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8593, USA
| | - Kevin J. Luebke
- Center for Biomedical Inventions, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8573, USA
- Corresponding author. Fax: +1-214-648-4156. (K.J. Luebke)
| | - Harold R. Garner
- Center for Biomedical Inventions, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8573, USA
- McDermott Center for Human Growth and Development, University of Texas Southwestern Medical Center at Dallas, Dallas, TX 75390-8591, USA
| |
Collapse
|
57223
|
Mao H, Holden MA, You M, Cremer PS. Reusable platforms for high-throughput on-chip temperature gradient assays. Anal Chem 2002; 74:5071-5. [PMID: 12380832 DOI: 10.1021/ac025851z] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
This paper describes a reusable platform that can apply a linear temperature gradient to a lab-on-a-chip device. When a planar microfluidic device with a series of microchannels is placed on top of the platform with the channels perpendicular to the gradient, each channel is held at a discrete temperature. This allows temperature-dependent data for chemical or biochemical species flowed into the device to be obtained in a concurrent fashion. As a demonstration, a melting curve for dsDNA is performed by collecting all the data simultaneously. The gradient is stable enough to easily distinguish between 30-mers where the complement strand contains a single C-A mismatch or a single T-G mismatch or is a perfect match. On the other hand, a temperature gradient can be formed parallel to the direction of flow of the microchannels. This allows the temperature in each channel to vary continuously as the liquid flows downstream. If each microchannel in the array contains a distinct pH value, ionic strength, species concentration, or chemical composition, then a high-throughput two-variable experiment can be performed. We demonstrate this mode of data collection by measuring the fluorescence yield of fluorescein dye molecules in aqueous solution simultaneously as a function of concentration and temperature.
Collapse
Affiliation(s)
- Hanbin Mao
- Department of Chemistry, Texas A&M University, College Station 77843, USA
| | | | | | | |
Collapse
|
57224
|
Emrich CA, Tian H, Medintz IL, Mathies RA. Microfabricated 384-lane capillary array electrophoresis bioanalyzer for ultrahigh-throughput genetic analysis. Anal Chem 2002; 74:5076-83. [PMID: 12380833 DOI: 10.1021/ac020236g] [Citation(s) in RCA: 231] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A microfabricated 384-lane capillary array electrophoresis device is developed and utilized for massively parallel genetic analysis. The 384 capillary lanes, arrayed radially about the center of a 200-mm-diameter glass substrate sandwich, are constructed using scalable microfabrication techniques derived from the semiconductor industry. Samples are loaded into reservoirs on the perimeter of the wafer, separated on the 8-cm-long poly(dimethylacrylamide) gel-filled channels, and detected with a four-color rotary confocal fluorescence scanner. The performance and throughput of this bioanalyzer are demonstrated by simultaneous genotyping 384 individuals for the common hemochromatosis-linked H63D mutation in the human HFE gene in only 325 s. This lab-on-a-chip device thoroughly exploits the power of microfabrication to produce high-density capillary electrophoresis arrays and to use them for high-throughput bioanalysis.
Collapse
Affiliation(s)
- Charles A Emrich
- Department of Chemistry, University of California, Berkeley 94720, USA
| | | | | | | |
Collapse
|
57225
|
Leigh R, Ostuni J, Pham D, Goldszal A, Lewis BK, Howard T, Richert N, McFarland H, Frank JA. Estimating cerebral atrophy in multiple sclerosis patients from various MR pulse sequences. Mult Scler 2002; 8:420-9. [PMID: 12356210 DOI: 10.1191/1352458502ms801oa] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
PURPOSE The purpose of this study was to determine how measures reflecting cerebral atrophy (CA) are influenced by pulse sequence (PS) and segmentation algorithm (SA) used in multiple sclerosis (MS) patients and healthy control (HC)s. METHODS Magnetic resonance imaging (MRI) scans from 10 relapsing-remitting MS (RRMS) patients and five HCs were used to determine the change in brain fractional volume (BFV) over a two-year period. T1-weighted, fluid-attenuated inversion recovery (FLAIR), and proton density (PD)/T2-weighted sequences were analysed Image segmentation to determine brain volume was performed using the following a histogram SA, an adaptive fuzzy c-means algorithm (AFCM), and an adaptive Bayesian segmentation with a K-means clustering. RESULTS Combinations of the SA and PS in MS patents demonstrated significant differences in the per cent change in BFV from baseline. For the combination of PS and SA the per cent change in BFV for year one and year two varied from +2.05% to - 1.6% and +0.79% to -3.11%, respectively. Analysis of the HCs data revealed fluctuations in BFV varying from +0.26% to -0.29%. CONCLUSIONS MRI estimates of CA are dependent on both the type of PS and SA; therefore, the choice of SA technique and PS should be consistent during an MS treatment trial. The progression of CA in MS should only be used as a secondary or tertiary outcome measure in treatment trials until a better understanding of how this measurement is affected by the disease, the image acquisition and analysis techniques.
Collapse
Affiliation(s)
- R Leigh
- Neuroimmunology Branch, National Institutes of Neurological Diseases and Stroke, National Institutes of Health, Clinical Center, Bethesda, Maryland 20892, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
57226
|
Abstract
Brain atlases and associated databases have great potential as gateways for navigating, accessing, and visualizing a wide range of neuroscientific data. Recent progress towards realizing this potential includes the establishment of probabilistic atlases, surface-based atlases and associated databases, combined with improvements in visualization capabilities and internet access.
Collapse
Affiliation(s)
- David C Van Essen
- Department of Anatomy & Neurobiology, Washington University School of Medicine, 660 South Euclid Avenue, St. Louis, Missouri 63110, USA
| |
Collapse
|
57227
|
Abstract
Cytotoxic chemotherapy or radiotherapy of cancer is limited by serious, sometimes life-threatening, side effects that arise from toxicities to sensitive normal cells because the therapies are not selective for malignant cells. So how can selectivity be improved? One strategy is to couple the therapeutics to antibodies or other ligands that recognize tumour-associated antigens. This increases the exposure of the malignant cells, and reduces the exposure of normal cells, to the ligand-targeted therapeutics.
Collapse
Affiliation(s)
- Theresa M Allen
- Department of Pharmacology, University of Alberta, Edmonton, Alberta, Canada T6G 2H7.
| |
Collapse
|
57228
|
Wang X, Mao JJ. Chondrocyte proliferation of the cranial base cartilage upon in vivo mechanical stresses. J Dent Res 2002; 81:701-5. [PMID: 12351669 DOI: 10.1177/154405910208101009] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Whereas the growth of the cranial base cartilage is thought to be regulated solely by genes, epiphyseal growth plates are known to respond to mechanical stresses. This disparity has led to our hypothesis that chondrocyte proliferation is accelerated by mechanical stimuli above natural growth. Two-Newton tensile forces with static and cyclic waveforms were delivered in vivo to the premaxillae of actively growing rabbits for 20 min/day over 12 consecutive days. The average number of BrdU-labeled chondrocytes in the proliferating zone treated with cyclic forces was significantly higher than both static forces of matching peak magnitude and sham controls representing natural chondral growth. Cyclic forces also evoked greater area of the proliferating zone than both static forces and sham controls. Thus, chondrocyte proliferation is enhanced by mechanical stresses in vivo, especially those with oscillatory waveform. Analysis of these data suggests that genetically coded chondral growth is up-regulated by mechanical signals.
Collapse
Affiliation(s)
- X Wang
- Skeletal Tissue Engineering Laboratory, Rm 237, Department of Orthodontics and Bioengineering, Univ. of Illinois at Chicago MC 841, 801 South Paulina Street, Chicago, IL 60612-7211, USA
| | | |
Collapse
|
57229
|
McIntyre CC, Grill WM. Extracellular stimulation of central neurons: influence of stimulus waveform and frequency on neuronal output. J Neurophysiol 2002; 88:1592-604. [PMID: 12364490 DOI: 10.1152/jn.2002.88.4.1592] [Citation(s) in RCA: 252] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The objective of this project was to examine the influence of stimulus waveform and frequency on extracellular stimulation of neurons with their cell bodies near the electrode (local cells) and fibers of passage in the CNS. Detailed computer-based models of CNS cells and axons were developed that accurately reproduced the dynamic firing properties of mammalian motoneurons including afterpotential shape, spike-frequency adaptation, and firing frequency as a function of stimulus amplitude. The neuron models were coupled to a three-dimensional finite element model of the spinal cord that solved for the potentials generated in the tissue medium by an extracellular electrode. Extracellular stimulation of the CNS with symmetrical charge balanced biphasic stimuli resulted in activation of fibers of passage, axon terminals, and local cells around the electrode at similar thresholds. While high stimulus frequencies enhanced activation of fibers of passage, a much more robust technique to achieve selective activation of targeted neuronal populations was via alterations in the stimulus waveform. Asymmetrical charge-balanced biphasic stimuli, consisting of a long-duration low-amplitude cathodic prepulse phase followed by a short-duration high-amplitude anodic stimulus phase, enabled selective activation of local cells. Conversely, an anodic prepulse phase followed by a cathodic stimulus phase enabled selective activation of fibers of passage. The threshold for activation of axon terminals in the vicinity of the electrode was lower than the threshold for direct activation of local cells, independent of the stimulus waveform. As a result, stimulation induced trans-synaptic influences (indirect depolarization/hyperpolarization) on local cells altered their neural output, and this indirect effect was dependent on stimulus frequency. If the indirect activation of local cells was inhibitory, there was little effect on the stimulation induced neural output of the local cells. However, if the indirect activation of the local cells was excitatory, attempts to activate selectively fibers of passage over local cells was limited. These outcomes provide a biophysical basis for understanding frequency-dependent outputs during CNS stimulation and provide useful tools for selective stimulation of the CNS.
Collapse
Affiliation(s)
- Cameron C McIntyre
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106-4912, USA
| | | |
Collapse
|
57230
|
Hasselbrink EF, Shepodd TJ, Rehm JE. High-pressure microfluidic control in lab-on-a-chip devices using mobile polymer monoliths. Anal Chem 2002; 74:4913-8. [PMID: 12380812 DOI: 10.1021/ac025761u] [Citation(s) in RCA: 85] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We have developed a nonstick polymer formulation for creating moving parts inside of microfluidic channels and have applied the technique to create piston-based devices that overcome several microfluidic flow control challenges. The parts were created bycompletely filling the channels of a glass microfluidic chip with the monomer/ solvent/initiator components of a nonstick photopolymer and then selectively exposing the chip to UV light in order to define mobile pistons (or other quasi-two-dimensional shapes) inside the channels. Stops defined in the substrate prevent the part from flushing out of the device but also provide sealing surfaces so that valves and other flow control devices are possible. Sealing against pressures greater than 30 MPa (4,500 psi) and actuation times less than 33 ms are observed. An on-chip check valve, a diverter valve, and a 10-nL pipet are demonstrated. This valving technology, coupled with high-pressure electrokinetic pumps, should make it possible to create a completely integrated HPLC system on a chip.
Collapse
|
57231
|
MacDonald IC, Groom AC, Chambers AF. Cancer spread and micrometastasis development: quantitative approaches for in vivo models. Bioessays 2002; 24:885-93. [PMID: 12325121 DOI: 10.1002/bies.10156] [Citation(s) in RCA: 114] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Death from cancer is usually due to metastasis. Fortunately, most cells that escape from a primary tumor fail to form metastases. Identifying reasons for this failure will help development of anti-metastatic therapies. Intravital videomicroscopy (IVVM) can be used to observe cancer cells injected into live animals. Co-injected microspheres can be used to assess cell survival. These techniques have been used to show that circulating tumor cells generally arrest in the microcirculation and may extravasate with high efficiency. While many tumor cells may survive in a secondary site, only a small subset form micrometastases and only a subset of these micrometastases persist to form vascularized macrometastases. Furthermore, solitary tumor cells may remain dormant for long periods of time in secondary sites. These findings suggest that metastatic growth and angiogenesis are prime targets for anti-metastatic therapy.
Collapse
Affiliation(s)
- Ian C MacDonald
- Department of Medical Biophysics, University of Western Ontario, London, Canada
| | | | | |
Collapse
|
57232
|
Turning quantity into quality: novel quality assurance strategies for data produced by high-throughput genomics technologies. ACTA ACUST UNITED AC 2002. [DOI: 10.1016/s1477-3627(02)02207-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
57233
|
Wang X, Mao JJ. Accelerated chondrogenesis of the rabbit cranial base growth plate by oscillatory mechanical stimuli. J Bone Miner Res 2002; 17:1843-50. [PMID: 12369788 DOI: 10.1359/jbmr.2002.17.10.1843] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
How mechanical stimuli modulate chondral growth is not well understood. To test a hypothesis that chondral growth is accelerated by oscillatory mechanical stimuli rather than the peak magnitude of mechanical force, we delivered 2-N tensile forces with static (frequency = 0 Hz) and cyclic (f = 1 Hz) profiles noninvasively to the maxillae of growing New Zealand white rabbits for 20 minutes/day over 12 days. Computerized histomorphometry revealed significantly greater maximum height of the cranial base growth plate (GP) treated with cyclic forces (870 +/- 130 microm) than static forces (654 +/- 29 microm) and sham controls (566 +/- 47 microm). In addition, the average total GP area treated with cyclic forces (2.63 +/- 0.17 mm2) was significantly greater than static forces (2.12 +/- 0.99 mm2) and sham controls (1.65 +/- 0.13 mm2). The proliferating zone of GPs treated with cyclic forces (158 +/- 38.5 microm) was significantly longer than the corresponding zones of static forces (117 +/- 8.6 microm) and sham controls (54 +/- 14.9 microm). The average number of chondrocytes in the proliferating zone treated with cyclic forces (1045 +/- 127) was significantly greater than static forces (632 +/- 85) and sham controls (632 +/- 60) in standardized grids. Like natural GPs, the cartilage matrix treated with cyclic and static tensile forces consisted of abundant aggrecan-like proteoglycans. These findings indicate that oscillatory components of mechanical force rather than its peak magnitude are potent anabolic stimulus for chondral growth. A cascade of oscillatory mechanical stimuli is likely capable of engineering chondral growth beyond naturally occurring chondrogenesis.
Collapse
Affiliation(s)
- Xin Wang
- Department of Orthodontics, University of Illinois at Chicago, 60612-7211, USA
| | | |
Collapse
|
57234
|
Alsberg E, Anderson KW, Albeiruti A, Rowley JA, Mooney DJ. Engineering growing tissues. Proc Natl Acad Sci U S A 2002; 99:12025-30. [PMID: 12218178 PMCID: PMC129392 DOI: 10.1073/pnas.192291499] [Citation(s) in RCA: 329] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2002] [Indexed: 01/18/2023] Open
Abstract
Regenerating or engineering new tissues and organs may one day allow routine replacement of lost or failing tissues and organs. However, these engineered tissues must not only grow to fill a defect and integrate with the host tissue, but often they must also grow in concert with the changing needs of the body over time. We hypothesized that tissues capable of growing with time could be engineered by supplying growth stimulus signals to cells from the biomaterial used for cell transplantation. In this study, chondrocytes and osteoblasts were cotransplanted on hydrogels modified with an RGD-containing peptide sequence to promote cell multiplication. New bone tissue was formed that grew in mass and cellularity by endochondral ossification in a manner similar to normal long-bone growth. Transplanted cells organized into structures that morphologically and functionally resembled growth plates. These engineered tissues could find utility in treating diseases and injuries of the growth plate, testing the effect of experimental drugs on growth-plate function and development, and investigating the biology of long-bone growth. Furthermore, this concept of promoting the growth of engineered tissues could find great utility in engineering numerous tissue types by way of the transplantation of a small number of precursor cells.
Collapse
Affiliation(s)
- Eben Alsberg
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | | | | | | | | |
Collapse
|
57235
|
Tsapis N, Bennett D, Jackson B, Weitz DA, Edwards DA. Trojan particles: large porous carriers of nanoparticles for drug delivery. Proc Natl Acad Sci U S A 2002; 99:12001-5. [PMID: 12200546 PMCID: PMC129387 DOI: 10.1073/pnas.182233999] [Citation(s) in RCA: 353] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
We have combined the drug release and delivery potential of nanoparticle (NP) systems with the ease of flow, processing, and aerosolization potential of large porous particle (LPP) systems by spray drying solutions of polymeric and nonpolymeric NPs into extremely thin-walled macroscale structures. These hybrid LPPs exhibit much better flow and aerosolization properties than the NPs; yet, unlike the LPPs, which dissolve in physiological conditions to produce molecular constituents, the hybrid LPPs dissolve to produce NPs, with the drug release and delivery advantages associated with NP delivery systems. Formation of the large porous NP (LPNP) aggregates occurs via a spray-drying process that ensures the drying time of the sprayed droplet is sufficiently shorter than the characteristic time for redistribution of NPs by diffusion within the drying droplet, implying a local Peclet number much greater than unity. Additional control over LPNPs physical characteristics is achieved by adding other components to the spray-dried solutions, including sugars, lipids, polymers, and proteins. The ability to produce LPNPs appears to be largely independent of molecular component type as well as the size or chemical nature of the NPs.
Collapse
Affiliation(s)
- N Tsapis
- Department of Physics, and Division of Engineering and Applied Sciences, Harvard University, 9 Oxford Street, Cambridge, MA 02138, USA
| | | | | | | | | |
Collapse
|
57236
|
Takano H, Sul JY, Mazzanti ML, Doyle RT, Haydon PG, Porter MD. Micropatterned substrates: approach to probing intercellular communication pathways. Anal Chem 2002; 74:4640-6. [PMID: 12349965 DOI: 10.1021/ac0257400] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Intercellular signaling is critical for the normal development and physiology of the central nervous system (CNS). To study such signaling, it is vital to control where and when the cells make contact with one another. It is also important to determine whether the process used for cell localization has an impact on signaling. This paper describes a technique that controls the location for cell growth in vitro and demonstrates that the technique has minimal (if any) impact on intercellular signaling. By using photolithographic methods, poly(dimethylsiloxane) molds were fabricated to function as templates for micrometer-level patterning of a nonadhesive agar (agarose) onto glass coverslips coated with a cell adhesive film (poly(L-lysine)). This process yields a surface composed of well-defined adhesive and nonadhesive microdomains. When endothelia or astrocytes are plated onto these substrates, confluent domains of endothelia or astrocytes grow on the poly(L-lysine) domains. Cocultures of astrocytes and neurons can also successfully be used to form interwoven networks on the adhesive domains. Moreover, studies of calcium signaling revealed that astrocytes grown on such patterns retain their native physiological activity. This conclusion is based on the observed propagation rate for calcium waves within individual astrocyte domains and across neighboring, but spatially disconnected, astrocyte domains. The potential to apply these micropatterned substrates as platforms for interrogating communication pathways in key components of the CNS is discussed.
Collapse
Affiliation(s)
- Hajime Takano
- Department of Chemistry, Iowa State University, Ames 50011, USA
| | | | | | | | | | | |
Collapse
|
57237
|
Mickiewicz RA, Mayes AM, Knaack D. Polymer--calcium phosphate cement composites for bone substitutes. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 2002; 61:581-92. [PMID: 12115448 DOI: 10.1002/jbm.10222] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The use of self-setting calcium phosphate cements (CPCs) as bioresorbable bone-replacement implant materials presently is limited to non-load-bearing applications because of their low compressive strength relative to natural bone. The present study investigated the possibility of strengthening a commercially available CPC, alpha-BSM, by incorporating various water-soluble polymers into the cement paste during setting. Several polyelectrolytes, poly(ethylene oxide), and the protein bovine serum albumin (BSA) were added in solution to the cement paste to create calcium phosphate-polymer composites. Composites formulated with the polycations poly(ethylenimine) and poly(allylamine hydrochloride) exhibited compressive strengths up to six times greater than that of pure alpha-BSM material, with a maximum value reached at intermediate polymer content and for the highest molecular weight studied. Composites containing BSA developed compressive strengths twice that of the original cement at protein concentrations of 13-25% by weight. In each case, XRD studies correlate the improvement in compressive strength with reduced crystallite dimensions, as evidenced by a broadening of the (0,0,2) reflection. This suggests that polycation or BSA adsorption inhibits crystal growth and possibly leads to a larger crystal aspect ratio. SEM results indicate a denser, more interdigitated microstructure. The increased strength was attributed to the polymer's capacity to bridge between multiple crystallites (thus forming a more cohesive composite) and to absorb energy through plastic flow.
Collapse
Affiliation(s)
- Rafal A Mickiewicz
- Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139-4307, USA
| | | | | |
Collapse
|
57238
|
Lev A, Novak H, Segal D, Reiter Y. Recruitment of CTL activity by tumor-specific antibody-mediated targeting of single-chain class I MHC-peptide complexes. JOURNAL OF IMMUNOLOGY (BALTIMORE, MD. : 1950) 2002; 169:2988-96. [PMID: 12218113 DOI: 10.4049/jimmunol.169.6.2988] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The MHC class I-restricted CD8 CTL effector arm of the adaptive immune response is uniquely equipped to recognize tumor cells as foreign and consequently initiates the cascade of events resulting in their destruction. However, tumors have developed sophisticated strategies to escape immune effector mechanisms; their most well-known strategy is down-regulation of MHC class I molecules. To overcome this and develop new approaches for immunotherapy, we have constructed a recombinant molecule in which a single-chain MHC is specifically targeted to tumor cells through its fusion to cancer-specific recombinant Ab fragments. As a model we used a single-chain HLA-A2 molecule genetically fused to the variable domains of an anti-IL-2Ralpha subunit-specific humanized Ab, anti-Tac. The construct, termed B2M-aTac(dsFv), was expressed in Escherichia coli, and functional molecules were produced by in vitro refolding in the presence of HLA-A2-restricted antigenic peptides. Flow cytometry studies revealed the ability to decorate Ag-positive, HLA-A2-negative human tumor cells with HLA-A2-peptide complexes in a manner that was entirely dependent upon the specificity of the targeting Ab fragment. Most importantly, the B2M-aTac(dsFv)-mediated coating of the target tumor cells made them susceptible for efficient and specific HLA-A2-restricted, melanoma gp100 peptide-specific CTL-mediated lysis. These results demonstrate the concept that Ab-guided, Ag-specific targeting of MHC-peptide complexes on tumor cells can render them susceptible and more receptive and thus potentiate CTL killing. This type of approach may open the way for the development of new immunotherapeutic strategies based on Ab targeting of natural cognate MHC ligands and CTL-based cytotoxic mechanisms.
Collapse
MESH Headings
- Animals
- Antibodies, Monoclonal/genetics
- Antibodies, Monoclonal/metabolism
- Antibody-Dependent Cell Cytotoxicity/genetics
- Antigens, Neoplasm/genetics
- Antineoplastic Agents/administration & dosage
- Antineoplastic Agents/chemical synthesis
- Antineoplastic Agents/isolation & purification
- Antineoplastic Agents/metabolism
- Binding Sites, Antibody/genetics
- Binding Sites, Antibody/immunology
- Carcinoma, Squamous Cell/immunology
- Carcinoma, Squamous Cell/metabolism
- Cytotoxicity Tests, Immunologic/methods
- Genetic Vectors/chemical synthesis
- Genetic Vectors/isolation & purification
- Genetic Vectors/metabolism
- Genetic Vectors/pharmacology
- HLA-A2 Antigen/genetics
- HLA-A2 Antigen/immunology
- HLA-A2 Antigen/metabolism
- Humans
- Immunoglobulin Fragments/genetics
- Injections, Subcutaneous
- Membrane Glycoproteins/genetics
- Mice
- Mice, Nude
- Peptide Fragments/genetics
- Receptors, Interleukin-2/genetics
- Receptors, Interleukin-2/immunology
- Recombinant Fusion Proteins/chemical synthesis
- Recombinant Fusion Proteins/isolation & purification
- Recombinant Fusion Proteins/metabolism
- Recombinant Fusion Proteins/pharmacology
- T-Lymphocytes, Cytotoxic/immunology
- T-Lymphocytes, Cytotoxic/metabolism
- Tumor Cells, Cultured
- beta 2-Microglobulin/genetics
- beta 2-Microglobulin/immunology
- beta 2-Microglobulin/metabolism
- gp100 Melanoma Antigen
Collapse
Affiliation(s)
- Avital Lev
- Faculty of Biology, Technion-Israel Institute of Technology, Haifa, Israel
| | | | | | | |
Collapse
|
57239
|
Tian P, Warren WS. Ultrafast measurement of two-photon absorption by loss modulation. OPTICS LETTERS 2002; 27:1634-6. [PMID: 18026525 DOI: 10.1364/ol.27.001634] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We demonstrate a direct and sensitive technique for measuring two-photon absorption (TPA). An intensity-modulated femtosecond laser beam passes through a sample exhibiting TPA. A TPA signal at twice the modulation frequency is then generated and subsequently measured by a lock-in amplifier. The absolute TPA cross section of Rhodamine 6G at 800nm is found to be (15.3+/-2.0)x10(-50) cm(4) s/photon and agrees well with previously published results obtained with much higher intensity [J.Chem.Phys.112, 9201 (2000)]. Our method may be especially useful in measuring nonlinear absorptions of nonfluorescent materials.
Collapse
|
57240
|
Haes AJ, Van Duyne RP. A nanoscale optical biosensor: sensitivity and selectivity of an approach based on the localized surface plasmon resonance spectroscopy of triangular silver nanoparticles. J Am Chem Soc 2002; 124:10596-604. [PMID: 12197762 DOI: 10.1021/ja020393x] [Citation(s) in RCA: 953] [Impact Index Per Article: 41.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Triangular silver nanoparticles ( approximately 100 nm wide and 50 nm high) have remarkable optical properties. In particular, the peak extinction wavelength, lambda(max) of their localized surface plasmon resonance (LSPR) spectrum is unexpectedly sensitive to nanoparticle size, shape, and local ( approximately 10-30 nm) external dielectric environment. This sensitivity of the LSPR lambda(max) to the nanoenvironment has allowed us to develop a new class of nanoscale affinity biosensors. The essential characteristics and operational principles of these LSPR nanobiosensors will be illustrated using the well-studied biotin-streptavidin system. Exposure of biotin-functionalized Ag nanotriangles to 100 nM streptavidin (SA) caused a 27.0 nm red-shift in the LSPR lambda(max). The LSPR lambda(max) shift, DeltaR/DeltaR(max), versus [SA] response curve was measured over the concentration range 10(-)(15) M < [SA] < 10(-)(6) M. Comparison of the data with the theoretical normalized response expected for 1:1 binding of a ligand to a multivalent receptor with different sites but invariant affinities yielded approximate values for the saturation response, DeltaR(max) = 26.5 nm, and the surface-confined thermodynamic binding constant K(a,surf) = 10(11) M(-)(1). At present, the limit of detection (LOD) for the LSPR nanobiosensor is found to be in the low-picomolar to high-femtomolar region. A strategy to amplify the response of the LSPR nanobiosensor using biotinylated Au colloids and thereby further improve the LOD is demonstrated. Several control experiments were performed to define the LSPR nanobiosensor's response to nonspecific binding as well as to demonstrate its response to the specific binding of another protein. These include the following: (1) electrostatic binding of SA to a nonbiotinylated surface, (2) nonspecific interactions of prebiotinylated SA to a biotinylated surface, (3) nonspecific interactions of bovine serum albumin to a biotinylated surface, and (4) specific binding of anti-biotin to a biotinylated surface. The LSPR nanobiosensor provides a pathway to ultrasensitive biodetection experiments with extremely simple, small, light, robust, low-cost instrumentation that will greatly facilitate field-portable environmental or point-of-service medical diagnostic applications.
Collapse
Affiliation(s)
- Amanda J Haes
- Department of Chemistry, Northwestern University, Evanston, Illinois 60208-3113, USA
| | | |
Collapse
|
57241
|
Sachs K, Gifford D, Jaakkola T, Sorger P, Lauffenburger DA. Bayesian network approach to cell signaling pathway modeling. SCIENCE'S STKE : SIGNAL TRANSDUCTION KNOWLEDGE ENVIRONMENT 2002; 2002:pe38. [PMID: 12209052 DOI: 10.1126/stke.2002.148.pe38] [Citation(s) in RCA: 65] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
The modeling of cellular signaling pathways is an emerging field. Sachs et al. illustrate the application of Bayesian networks to an example cellular pathway involving the activation of focal adhesion kinase (FAK) and extracellular signal-regulated kinase (ERK) in response to fibronectin binding to an integrin. They describe how to use the analysis to select from among proposed models, formulate hypotheses regarding component interactions, and uncover potential dynamic changes in the interactions between these components. Although the data sets currently available for this example problem are too small to definitively point to a particular model, the approach and results provide a glimpse into the power that these methods will achieve once the technology for obtaining the necessary data becomes readily available.
Collapse
Affiliation(s)
- Karen Sachs
- Biological Engineering Division, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | | | | | | | | |
Collapse
|
57242
|
Horská A, Calhoun VD, Bradshaw DH, Barker PB. Rapid method for correction of CSF partial volume in quantitative proton MR spectroscopic imaging. Magn Reson Med 2002; 48:555-8. [PMID: 12210925 DOI: 10.1002/mrm.10242] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Partial volume effects with cerebrospinal fluid (CSF), if uncorrected, can lead to underestimation of metabolite concentrations in quantitative proton magnetic resonance spectroscopic imaging (MRSI) of the brain. A rapid method for the correction of CSF partial volume effects is described based on selective CSF imaging using long echo time (TE) fast spin echo (FSE) magnetic resonance imaging (MRI). In order to achieve maximum suppression of signal from brain parenchyma, the FSE sequence is coupled with an inversion recovery (IR) pulse. Scan time is minimized using single shot (SS) IR-FSE. The method is validated against a current "gold standard" for the determination of CSF volumes, namely, segmented 3D spoiled gradient-echo (SPGR) scans. Excellent agreement in CSF percentage determined by the two methods was found (linear regression analysis: slope = 0.99 +/- 0.02, intercept = 2.08 +/- 0.45; mean +/- standard errors, R = 0.93) in pooled data from four healthy subjects. An example of the use of SS-IR-FSE for partial volume correction in a leukodystrophy patient with T(2) hyperintense lesions is demonstrated. SS-IR-FSE is a simple and rapid method for applying partial volume corrections in quantitative proton MRSI, which may be of particular value in the clinical environment when time constraints do not allow longer, perhaps more accurate segmentation methods to be used.
Collapse
Affiliation(s)
- A Horská
- Division of Neuroradiology, Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, Maryland, USA
| | | | | | | |
Collapse
|
57243
|
Buerk DG, Riva CE. Adenosine enhances functional activation of blood flow in cat optic nerve head during photic stimulation independently from nitric oxide. Microvasc Res 2002; 64:254-64. [PMID: 12204650 DOI: 10.1006/mvre.2002.2432] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Blood flow studies in the brain, heart, and other organs suggest that there could be interaction between nitric oxide (NO) and adenosine. This possibility was investigated in the optic nerve head (ONH) during photic stimulation of the dark-adapted cat eye. Functional activation of ONH blood flow was measured by laser Doppler flowmetry, simultaneously with NO and PO(2) using double-barrel recessed electrochemical sensors. Photic stimulation (diffuse luminance flickering light at 30 Hz) increased ONH blood flow to 127.4 +/- 4.7% (mean +/- SEM) of baseline with a transient increase in NO by 79.8 +/- 12.8 nM, while PO(2) decreased from 24.5 +/- 2.7 to 22.7 +/- 2.4 Torr (control responses, 15 trials, 10 cats). Adenosine (3 mg/kg iv) increased baseline ONH blood flow to 113.8 +/- 8.4% of control within 5 min. Functional activation of ONH blood flow was enhanced during photic stimulation, reaching a maximum of 155.8 +/- 8.1% within 5 min, and remained enhanced for 30 to 45 min. NO responses during photic stimulation were not different from control responses. Treatment with a nonspecific NO synthase inhibitor (N(G)-nitro-L-arginine methyl ester, 40 mg/kg iv, 5 cats) did not alter the increase in resting ONH blood flow or the enhanced functional activation after adenosine. We conclude that there is no interaction between NO and adenosine during functional activation of cat ONH blood flow by photic stimulation.
Collapse
Affiliation(s)
- Donald G Buerk
- Department of Physiology, Department of Bioengineering, and the Institute for Environmental Medicine, University of Pennsylvania School of Medicine, Philadelphia, 19104-6085, USA.
| | | |
Collapse
|
57244
|
Dalton PD, Flynn L, Shoichet MS. Manufacture of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) hydrogel tubes for use as nerve guidance channels. Biomaterials 2002; 23:3843-51. [PMID: 12164188 DOI: 10.1016/s0142-9612(02)00120-5] [Citation(s) in RCA: 186] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Hydrogel tubes of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (p(HEMA-co-MMA)) made by liquid-liquid centrifugal casting are being investigated as potential nerve guidance channels in the central nervous system. An important criterion for the nerve guidance channel is that its mechanical properties are similar to those of the spinal cord, where it will be implanted. The formulated p(HEMA-co-MMA) tubes are soft and flexible, consisting of a gel-like outer layer, and an interconnected macroporous, inner layer. The relative thickness of the gel phase to macroporous phase is controlled by the formulation chemistry, and specifically by the ratio of co-monomers, HEMA and MMA. By varying the surface chemistry of the mold within which the tubes are synthesized, tubes were prepared with either a "cracked" or a smooth outer morphology. Tubes with the cracked outer morphology had periodic channels that traversed the wall of the tube, which resulted in a lower modulus than smooth outer morphology tubes, yet likely greater diffusive permeability. For tubes (and not rods) to be formed, phase separation must precede gelation as is detailed in a formulation phase diagram for HEMA, MMA and water. The tensile elastic modulus of p(HEMA-co-MMA) tubes reflected the formulation chemistry, with greater moduli (up to 400 kPa) recorded for tubes having 10 wt% MMA. The p(HEMA-co-MMA) tubes therefore had similar mechanical properties to those of the spinal cord, which has a reported elastic modulus range between 200 and 600 kPa.
Collapse
|
57245
|
Ramanujan S, Pluen A, McKee TD, Brown EB, Boucher Y, Jain RK. Diffusion and convection in collagen gels: implications for transport in the tumor interstitium. Biophys J 2002; 83:1650-60. [PMID: 12202388 PMCID: PMC1302261 DOI: 10.1016/s0006-3495(02)73933-7] [Citation(s) in RCA: 371] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Diffusion coefficients of tracer molecules in collagen type I gels prepared from 0-4.5% w/v solutions were measured by fluorescence recovery after photobleaching. When adjusted to account for in vivo tortuosity, diffusion coefficients in gels matched previous measurements in four human tumor xenografts with equivalent collagen concentrations. In contrast, hyaluronan solutions hindered diffusion to a lesser extent when prepared at concentrations equivalent to those reported in these tumors. Collagen permeability, determined from flow through gels under hydrostatic pressure, was compared with predictions obtained from application of the Brinkman effective medium model to diffusion data. Permeability predictions matched experimental results at low concentrations, but underestimated measured values at high concentrations. Permeability measurements in gels did not match previous measurements in tumors. Visualization of gels by transmission electron microscopy and light microscopy revealed networks of long collagen fibers at lower concentrations along with shorter fibers at high concentrations. Negligible assembly was detected in collagen solutions pregelation. However, diffusion was similarly hindered in pre and postgelation samples. Comparison of diffusion and convection data in these gels and tumors suggests that collagen may obstruct diffusion more than convection in tumors. These findings have significant implications for drug delivery in tumors and for tissue engineering applications.
Collapse
Affiliation(s)
- Saroja Ramanujan
- E. L. Steele Laboratory for Tumor Biology, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114, USA
| | | | | | | | | | | |
Collapse
|
57246
|
Kida I, Xu F, Shulman RG, Hyder F. Mapping at glomerular resolution: fMRI of rat olfactory bulb. Magn Reson Med 2002; 48:570-6. [PMID: 12210928 DOI: 10.1002/mrm.10248] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
The rat olfactory bulb contains approximately 2000 functional units called glomeruli which are used to recognize specific characteristics of odorants. Activity localization of individual glomerulae ( approximately 0.002 microL) has important consequences for understanding mechanisms in olfactory information encoding. High-resolution functional MRI (fMRI) data from the rat olfactory bulb are presented using the blood oxygenation level dependent (BOLD) method at 7 T. Either individual or clusters of fMRI voxels suggestive of activity in the olfactory nerve and glomerular layers were reproducibly detected with repeated 2-min exposures of iso-amyl acetate at spatial resolution of 0.001-0.003 microL. The importance of glomerular clustering for olfaction and the implications of BOLD mapping with even higher spatial resolution (i.e., <<0.001 microL voxels) are discussed. High-resolution in vivo mapping of the rat olfactory bulb with fMRI at high magnetic field promises to provide novel data for understanding olfaction.
Collapse
Affiliation(s)
- Ikuhiro Kida
- Department of Diagnostic Radiology, Magnetic Resonance Research Center, Yale University, New Haven, Connecticut 06510, USA
| | | | | | | |
Collapse
|
57247
|
Gerstner RB, Carter P, Lowman HB. Sequence plasticity in the antigen-binding site of a therapeutic anti-HER2 antibody. J Mol Biol 2002; 321:851-62. [PMID: 12206766 DOI: 10.1016/s0022-2836(02)00677-0] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
We have examined the plasticity of the antigen-combining site of a high-affinity antibody. In phage-displayed Fab libraries, selected CDR positions and one FR position of the humanized anti-Her2 antibody hu4D5 were substituted with all 20 amino acids. Antigen-binding selections were used to enrich for high-affinity variants, and a large number of sequences were obtained prior to convergence of the selected pool to a small set of clones. As expected, sequence variability of the antigen-binding site is overall diminished compared to known IgG sequences; however, certain positions retain much higher variability than others. The sequence variability map of the hu4D5 binding site is compared with a map derived from previous alanine-scanning of the antibody. Affinities of soluble Fab fragments for antigen confirm that multiple variants were selected with high affinity for antigen, including one variant with a single point mutation that was about threefold improved in affinity compared to the parental hu4D5. Interestingly, this mutation is one of the most radical in terms of changing side-chain chemistry (Trp for Asp) and occurs at the most plastic site as calculated by the Wu-Kabat variability coefficient. Thus variability mapping yields information about the antibody-antigen interaction that is useful and complementary to that obtained by alanine scanning mutagenesis.
Collapse
MESH Headings
- Alanine/genetics
- Amino Acid Substitution
- Antibodies, Monoclonal/chemistry
- Antibodies, Monoclonal/genetics
- Antibodies, Monoclonal/immunology
- Antibodies, Monoclonal/therapeutic use
- Antibodies, Monoclonal, Humanized
- Antibody Affinity
- Antigens, Neoplasm/immunology
- Antineoplastic Agents/chemistry
- Antineoplastic Agents/immunology
- Antineoplastic Agents/therapeutic use
- Binding Sites, Antibody
- Immunoglobulin Fab Fragments/chemistry
- Immunoglobulin Fab Fragments/immunology
- Models, Molecular
- Mutation
- Neoplasms/therapy
- Peptide Library
- Protein Binding
- Receptor, ErbB-2/immunology
- Trastuzumab
Collapse
Affiliation(s)
- Resi B Gerstner
- Department of Protein Engineering, Genentech, Inc., 1 DNA Way, South San Francisco, CA 94080, USA
| | | | | |
Collapse
|
57248
|
Ravasz E, Somera AL, Mongru DA, Oltvai ZN, Barabási AL. Hierarchical organization of modularity in metabolic networks. Science 2002; 297:1551-5. [PMID: 12202830 DOI: 10.1126/science.1073374] [Citation(s) in RCA: 2005] [Impact Index Per Article: 87.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Spatially or chemically isolated functional modules composed of several cellular components and carrying discrete functions are considered fundamental building blocks of cellular organization, but their presence in highly integrated biochemical networks lacks quantitative support. Here, we show that the metabolic networks of 43 distinct organisms are organized into many small, highly connected topologic modules that combine in a hierarchical manner into larger, less cohesive units, with their number and degree of clustering following a power law. Within Escherichia coli, the uncovered hierarchical modularity closely overlaps with known metabolic functions. The identified network architecture may be generic to system-level cellular organization.
Collapse
Affiliation(s)
- E Ravasz
- Department of Physics, University of Notre Dame, Notre Dame, IN 46556, USA
| | | | | | | | | |
Collapse
|
57249
|
Rackaitis M, Strawhecker K, Manias E. Water-soluble polymers with tunable temperature sensitivity: Solution behavior. ACTA ACUST UNITED AC 2002. [DOI: 10.1002/polb.10284] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
57250
|
Lefesvre P, Attema J, van Bekkum D. A comparison of efficacy and toxicity between electroporation and adenoviral gene transfer. BMC Mol Biol 2002; 3:12. [PMID: 12175426 PMCID: PMC122059 DOI: 10.1186/1471-2199-3-12] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2002] [Accepted: 08/13/2002] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Electroporation of skeletal muscle after injection of naked DNA was shown by others to increase transgene expression. Information regarding tissue damage caused by electroporation is conflicting. It is also not well known how plasmid electroporation compares with transfection by adenoviral vectors. To investigate these questions the most used protocol for muscle electroporation was used, i.e. 8 pulses of 200 V/cm and 20 ms at a frequency of 1 Hz. RESULTS Intra-muscular DNA transfer of pLuciferase was increased by 2 logs after electroporation, confirming data described by others. However, the blood levels of the encoded protein were still lower than those obtained after injection of first generation adenoviral vectors. Also, the electroporation procedure, on its own, caused severe muscle damage consisting of rhabdomyolysis and infiltration, whereas the adenoviral vectors caused only a slight infiltration. As damage of targeted tissue may be an advantage in the case of tumour transfection, we also compared the two transfection methods in tumour tissue. In case of poorly permissive tumours, adenoviral vectors cannot transfect more than 2% of the tumour tissue without inducing significant liver damage. In contrast, the electroporation seems to offer a wider therapeutic window since it does not cause any systemic toxicity and still induce's significant transfection. CONCLUSIONS Plasmid electroporation of the muscle induce severe local damage and is of no advantage over adenoviral vectors for obtaining high blood levels of a vector encoded protein. In contrast, electroporation of tumours might be safer than adenoviral gene transfer.
Collapse
Affiliation(s)
| | - Joline Attema
- Crucell BV, PO BOX 2048, 2301CA, Leiden, The Netherlands
| | | |
Collapse
|