151
|
Strohmaier C, Schmithausen AJ, Krommweh MS, Diekmann B, Büscher W. Evaluation of a dry filter for dust removal under laboratory conditions in comparison to practical use at a laying hen barn. Environ Sci Pollut Res Int 2018; 25:29511-29517. [PMID: 30136184 DOI: 10.1007/s11356-018-2981-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Accepted: 08/15/2018] [Indexed: 06/08/2023]
Abstract
The high amount of particulate matter from poultry houses in the exhaust air, especially at different types of laying hen barns, is the main challenge farmers are faced with concerning emissions. As a possibility for the mitigation of particulate matter in the outgoing air, a dry filter based on the principle of centrifugal force was investigated under laboratory and field conditions. Aerosol spectrometers were used for continuous measurements in raw and clean gas. Field experiments took place under summer and winter conditions, so that filter efficiency under different climate conditions could be compared and measurement values at the barn were continuously collected over 24-h periods. Data collected under laboratory conditions showed a high efficiency of the dry filter, whereas results of the field experiments differed in each size fraction of the particulate matter. These differences may be explained by the fact that under laboratory conditions, better circumstances for correct measuring were created, e.g., laminar flow of the air.
Collapse
Affiliation(s)
- Carolina Strohmaier
- Institute of Agricultural Engineering, University of Bonn, Nußallee 5, 53115, Bonn, Germany.
| | | | - Manuel S Krommweh
- Institute of Agricultural Engineering, University of Bonn, Nußallee 5, 53115, Bonn, Germany
| | - Bernd Diekmann
- Institute of Physics, University of Bonn, Nußallee 12, 53115, Bonn, Germany
| | - Wolfgang Büscher
- Institute of Agricultural Engineering, University of Bonn, Nußallee 5, 53115, Bonn, Germany
| |
Collapse
|
152
|
Abstract
UNLABELLED Excessive accumulation of biomass within gas-phase biofilters often results in the deterioration of removal performance. Compared with chemical and biological technologies, physical technologies are more effective in removing biomass and inducing less inhibition of the biofilter performance. This study applied different physical technologies, namely, air sparging, mechanical mixing, and washing with water at various temperatures, to remove excess biomass in biofilters treating toluene. Filter pressure drop, removed dry biomass, biofilter performance, and microbial metabolic characteristics were analyzed to evaluate the effectiveness of the methods. Results showed that air sparging was inefficient for biomass removal (1 kg dry biomass/m3 filter), whereas mechanical mixing significantly inhibited removal efficiencies (<30%). Washing of the packing with fluids was feasible, and hot fluids can remove a large amount of biomass. However, hot fluids reduce microbial activity and inhibit removal performance. Washing of the packing with either 20°C or 50°C water showed efficiency as >3 kg dry biomass/m3 filter can be removed at both temperatures with removal efficiencies at approximately 40% after treatment. Finally, different technologies were compared and summarized to propose an optimized strategy of biomass control for industrial biofilters. IMPLICATIONS This study is to apply different physical technologies, namely, air sparging, mechanical mixing, and washing with water of different temperatures, to remove the excess biomass in biofilters treating toluene. The filter pressure drop, removed dry biomass, biofilter performance, and microbial metabolic characteristics were all analyzed to evaluate the effectiveness of the methods. The results of this study provide useful information regarding biomass control of industrial biofilters.
Collapse
Affiliation(s)
- Meng-Fei Han
- a Key Lab of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering , Tianjin University , Tianjin , China
| | - Can Wang
- a Key Lab of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering , Tianjin University , Tianjin , China
| | - Hang Liu
- a Key Lab of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering , Tianjin University , Tianjin , China
| |
Collapse
|
153
|
Qiu X, Lombardo JA, Westerhof TM, Pennell M, Ng A, Alshetaiwi H, Luna BM, Nelson EL, Kessenbrock K, Hui EE, Haun JB. Microfluidic filter device with nylon mesh membranes efficiently dissociates cell aggregates and digested tissue into single cells. Lab Chip 2018; 18:2776-2786. [PMID: 30090895 PMCID: PMC6171522 DOI: 10.1039/c8lc00507a] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Tissues are increasingly being analyzed at the single cell level in order to characterize cellular diversity and identify rare cell types. Single cell analysis efforts are greatly limited, however, by the need to first break down tissues into single cell suspensions. Current dissociation methods are inefficient, leaving a significant portion of the tissue as aggregates that are filtered away or left to confound results. Here, we present a simple and inexpensive microfluidic device that simultaneously filters large tissue fragments and dissociates smaller aggregates into single cells, thereby improving single cell yield and purity. The device incorporates two nylon mesh membranes with well-defined, micron-sized pores that operate on aggregates of different size scales. We also designed the device so that the first filtration could be performed under tangential flow to minimize clogging. Using cancer cell lines, we demonstrated that aggregates were effectively dissociated using high flow rates and pore sizes that were smaller than a single cell. However, pore sizes that were less than half the cell size caused significant damage. We then improved results by passing the sample through two filter devices in series, with single cell yield and purity predominantly determined by the pore size of the second membrane. Next, we optimized performance using minced and digested murine kidney tissue samples, and determined that the combination of 50 and 15 μm membranes was optimal. Finally, we integrated these two membranes into a single filter device and performed validation experiments using minced and digested murine kidney, liver, and mammary tumor tissue samples. The dual membrane microfluidic filter device increased single cell numbers by at least 3-fold for each tissue type, and in some cases by more than 10-fold. These results were obtained in minutes without affecting cell viability, and additional filtering would not be required prior to downstream applications. In future work, we will create complete tissue analysis platforms by integrating the dual membrane microfluidic filter device with additional upstream tissue processing technologies, as well as downstream operations such as cell sorting and detection.
Collapse
Affiliation(s)
- Xiaolong Qiu
- Department of Biomedical Engineering, University of California Irvine, 3107 Natural Sciences II, Irvine, CA 92697, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
154
|
San-Valero P, Gabaldón C, Álvarez-Hornos FJ, Izquierdo M, Martínez-Soria V. Removal of acetone from air emissions by biotrickling filters: providing solutions from laboratory to full-scale. J Environ Sci Health A Tox Hazard Subst Environ Eng 2018; 54:1-8. [PMID: 30193082 DOI: 10.1080/10934529.2018.1496552] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Revised: 06/18/2018] [Accepted: 06/25/2018] [Indexed: 06/08/2023]
Abstract
A full-scale biotrickling filter (BTF) treating acetone air emissions of wood-coating activities showed difficulties to achieve outlet concentrations lower than 125 mg C m-3, especially for high inlet concentrations and oscillating emissions. To solve this problem, a laboratory investigation on acetone removal was carried out simulating typical industrial conditions: discontinuous and variable inlet concentrations and intermittent spraying. The results were evaluated in terms of removal efficiency and outlet gas emission pattern. Industrial emissions and operational protocols were simulated: inlet load up to 70 g C m-3 h-1 during 2 cycles of 4 h per day and intermittent trickling of 15 min per hour. The outlet gas stream of the pollutant was affected by intermittent spraying, causing a fugitive emission of pollutant. Complete removal efficiency was obtained during non-spraying. Average removal efficiencies higher than 85% were obtained, showing the feasibility of BTF to treat acetone. The outlet gas stream showed a clear dependence on the pH of the trickling liquid, decreasing the removal at pH < 5.5. Thus, a proper control of alkalinity, with regular NaHCO3 addition, was required for successful operation. The laboratory findings were fruitfully transferred to the industry, and the removal of acetone by full-scale BTF was improved.
Collapse
Affiliation(s)
- Pau San-Valero
- a Research Group GI2AM, Department of Chemical Engineering , Universitat de València , Burjassot , Spain
| | - Carmen Gabaldón
- a Research Group GI2AM, Department of Chemical Engineering , Universitat de València , Burjassot , Spain
| | | | - Marta Izquierdo
- a Research Group GI2AM, Department of Chemical Engineering , Universitat de València , Burjassot , Spain
| | - Vicente Martínez-Soria
- a Research Group GI2AM, Department of Chemical Engineering , Universitat de València , Burjassot , Spain
| |
Collapse
|
155
|
Kerdi S, Qamar A, Vrouwenvelder JS, Ghaffour N. Fouling resilient perforated feed spacers for membrane filtration. Water Res 2018; 140:211-219. [PMID: 29715645 DOI: 10.1016/j.watres.2018.04.049] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2017] [Revised: 04/19/2018] [Accepted: 04/23/2018] [Indexed: 05/27/2023]
Abstract
The improvement of feed spacers with optimal geometry remains a key challenge for spiral-wound membrane systems in water treatment due to their impact on the hydrodynamic performance and fouling development. In this work, novel spacer designs are proposed by intrinsically modifying cylindrical filaments through perforations. Three symmetric perforated spacers (1-Hole, 2-Hole, and 3-Hole) were in-house 3D-printed and experimentally evaluated in terms of permeate flux, feed channel pressure drop and membrane fouling. Spacer performance is characterized and compared with standard no perforated (0-Hole) design under constant feed pressure and constant feed flow rate. Perforations in the spacer filaments resulted in significantly lowering the net pressure drop across the spacer filled channel. The 3-Hole spacer was found to have the lowest pressure drop (50%-61%) compared to 0-Hole spacer for various average flow velocities. Regarding permeate flux production, the 0-Hole spacer produced 5.7 L m-2.h-1 and 6.6 L m-2.h-1 steady state flux for constant pressure and constant feed flow rate, respectively. The 1-Hole spacer was found to be the most efficient among the perforated spacers with 75% and 23% increase in permeate production at constant pressure and constant feed flow, respectively. Furthermore, membrane surface of 1-Hole spacer was found to be cleanest in terms of fouling, contributing to maintain higher permeate flux production. Hydrodynamic understanding of these perforated spacers is also quantified by performing Direct Numerical Simulation (DNS). The performance enhancement of these perforated spacers is attributed to the formation of micro-jets in the spacer cell that aided in producing enough unsteadiness/turbulence to clean the membrane surface and mitigate fouling phenomena. In the case of 1-Hole spacer, the unsteadiness intensity at the outlet of micro-jets and the shear stress fluctuations created inside the cells are higher than those observed with other perforated spacers, resulting in the cleanest membrane surface.
Collapse
Affiliation(s)
- Sarah Kerdi
- King Abdullah University of Science and Technology (KAUST), Water Desalination and Reuse Center (WDRC), Biological and Environmental Science and Engineering (BESE), Thuwal 23955-6900, Saudi Arabia
| | - Adnan Qamar
- King Abdullah University of Science and Technology (KAUST), Water Desalination and Reuse Center (WDRC), Biological and Environmental Science and Engineering (BESE), Thuwal 23955-6900, Saudi Arabia
| | - Johannes S Vrouwenvelder
- King Abdullah University of Science and Technology (KAUST), Water Desalination and Reuse Center (WDRC), Biological and Environmental Science and Engineering (BESE), Thuwal 23955-6900, Saudi Arabia
| | - Noreddine Ghaffour
- King Abdullah University of Science and Technology (KAUST), Water Desalination and Reuse Center (WDRC), Biological and Environmental Science and Engineering (BESE), Thuwal 23955-6900, Saudi Arabia.
| |
Collapse
|
156
|
Divi RV, Strother JA, Paig-Tran EWM. Manta rays feed using ricochet separation, a novel nonclogging filtration mechanism. Sci Adv 2018; 4:eaat9533. [PMID: 30263959 PMCID: PMC6157963 DOI: 10.1126/sciadv.aat9533] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2018] [Accepted: 08/15/2018] [Indexed: 05/12/2023]
Abstract
Solid-liquid filtration is a ubiquitous process found in industrial and biological systems. Although implementations vary widely, almost all filtration systems are based on a small set of fundamental separation mechanisms, including sieve, cross-flow, hydrosol, and cyclonic separation. Anatomical studies showed that manta rays have a highly specialized filter-feeding apparatus that does not resemble previously described filtration systems. We examined the fluid flow around the manta filter-feeding apparatus using a combination of physical modeling and computational fluid dynamics. Our results indicate that manta rays use a unique solid-fluid separation mechanism in which direct interception of particles with wing-like structures causes particles to "ricochet" away from the filter pores. This filtration mechanism separates particles smaller than the pore size, allows high flow rates, and resists clogging.
Collapse
Affiliation(s)
- Raj V. Divi
- California State University, Fullerton, 800 North State College Boulevard, Fullerton, CA 92867, USA
| | - James A. Strother
- Oregon State University, 3029 Cordley Hall, Corvallis, OR 97330, USA
- Corresponding author. (E.W.M.P.-T.); (J.A.S.)
| | - E. W. Misty Paig-Tran
- California State University, Fullerton, 800 North State College Boulevard, Fullerton, CA 92867, USA
- Corresponding author. (E.W.M.P.-T.); (J.A.S.)
| |
Collapse
|
157
|
Bornemann G, Waßer K, Hauslage J. The influence of nitrogen concentration and precipitation on fertilizer production from urine using a trickling filter. Life Sci Space Res (Amst) 2018; 18:12-20. [PMID: 30100143 DOI: 10.1016/j.lssr.2018.04.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Revised: 02/27/2018] [Accepted: 04/30/2018] [Indexed: 06/08/2023]
Abstract
Planetary habitation requires technology to maintain natural microbial processes, which make nutrients from biowaste available for plant cultivation. This study describes a 646 day experiment, in which trickling filters were monitored for their ability to mineralize nitrogen when loaded with artificial urine solutions of different concentrations (40, 60, 80 and 100% v/v). Former studies have indicated that increasing urine concentrations slow nitrogen conversion rates and induce growing instability. In the current experiment, nitrogen conversion rates, measured as nitrate production/day, did not differ between concentration levels and increasing instability was not observed. Instead, the buffering capacity of the mussel shells added as buffer system (∼75% calcium carbonate) increased with increasing concentrations of synthetic urine possibly due to the higher phosphate content. The intensified precipitation of calcium phosphates seems to promote carbonate dissolution leading to improved buffering. For space applications, the precipitation of calcium phosphates is not desirable as for the phosphate to be available to the plants the precipitate must be treated with hazardous substances. With regard to terrestrial agriculture the process-integrated phosphate precipitation is a possibility to separate the macronutrients nitrogen and phosphate without addition of other chemicals. Thus, the described process offers a simple and cost-effective approach to fertilizer production from biogenic residues like slurry.
Collapse
Affiliation(s)
- Gerhild Bornemann
- German Aerospace Center, Institute of Aerospace Medicine, Gravitational Biology, Linder Hoehe, Cologne 51147, Germany.
| | - Kai Waßer
- German Aerospace Center, Institute of Aerospace Medicine, Gravitational Biology, Linder Hoehe, Cologne 51147, Germany
| | - Jens Hauslage
- German Aerospace Center, Institute of Aerospace Medicine, Gravitational Biology, Linder Hoehe, Cologne 51147, Germany
| |
Collapse
|
158
|
Rengasamy S, Zhuang Z, Niezgoda G, Walbert G, Lawrence R, Boutin B, Hudnall J, Monaghan WP, Bergman M, Miller C, Harris J, Coffey C. A comparison of total inward leakage measured using sodium chloride (NaCl) and corn oil aerosol methods for air-purifying respirators. J Occup Environ Hyg 2018; 15:616-627. [PMID: 29781773 PMCID: PMC6198249 DOI: 10.1080/15459624.2018.1479064] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Revised: 05/16/2018] [Accepted: 05/16/2018] [Indexed: 05/24/2023]
Abstract
The International Organization for Standardization (ISO) standard 16900-1:2014 specifies the use of sodium chloride (NaCl) and corn oil aerosols, and sulfur hexafluoride gas for measuring total inward leakage (TIL). However, a comparison of TIL between different agents is lacking. The objective of this study was to measure and compare TIL for respirators using corn oil and NaCl aerosols. TIL was measured with 10 subjects donning two models of filtering facepiece respirators (FFRs) including FFP1, N95, P100, and elastomeric half-mask respirators (ERs) in NaCl and corn oil aerosol test chambers, using continuous sampling methods. After fit testing with a PortaCount (TSI, Inc., St. Paul, MN) using the Occupational Safety and Health Administration (OSHA) protocol, five subjects were tested in the NaCl chamber first and then in the corn oil chamber, while other subjects tested in the reverse order. TIL was measured as a ratio of mass-based aerosol concentrations in-mask to the test chamber, while the subjects performed ISO 16900-1-defined exercises. The concentration of NaCl aerosol was measured using two flame photometers, and corn oil aerosol was measured with one light scattering photometer. The same instruments were used to measure filter penetration in both chambers using a Plexiglas setup. The size distribution of aerosols was determined using a scanning mobility particle sizer and charge was measured with an electrometer. Filter efficiency was measured using an 8130 Automated Filter Tester (TSI). Results showed the geometric mean TIL for corn oil aerosol for one model each of all respirator categories, except P100, were significantly (p < 0.05) greater than for NaCl aerosol. Filter penetration in the two test chambers showed a trend similar to TIL. The count median diameter was ∼82 nm for NaCl and ∼200 nm for corn oil aerosols. The net positive charge for NaCl aerosol was relatively larger. Both fit factor and filter efficiency influence TIL measurement. Overall, TIL determination with aerosols of different size distributions and charges using different methodologies may produce dissimilar results.
Collapse
Affiliation(s)
- Samy Rengasamy
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| | - Ziqing Zhuang
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| | - George Niezgoda
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| | - Gary Walbert
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| | - Robert Lawrence
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| | - Brenda Boutin
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| | - Judith Hudnall
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| | - William P Monaghan
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| | - Michael Bergman
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| | - Colleen Miller
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| | - James Harris
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| | - Christopher Coffey
- a National Institute for Occupational Safety and Health , National Personal Protective Technology Laboratory , Pittsburgh , Pennsylvania
| |
Collapse
|
159
|
Zhou NA, Fagnant-Sperati CS, Shirai JH, Sharif S, Zaidi SZ, Rehman L, Hussain J, Agha R, Shaukat S, Alam M, Khurshid A, Mujtaba G, Salman M, Safdar RM, Mahamud A, Ahmed J, Khan S, Kossik AL, Beck NK, Matrajt G, Asghar H, Bandyopadhyay AS, Boyle DS, Meschke JS. Evaluation of the bag-mediated filtration system as a novel tool for poliovirus environmental surveillance: Results from a comparative field study in Pakistan. PLoS One 2018; 13:e0200551. [PMID: 30011304 PMCID: PMC6047795 DOI: 10.1371/journal.pone.0200551] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Accepted: 06/28/2018] [Indexed: 01/06/2023] Open
Abstract
Poliovirus (PV) environmental surveillance (ES) plays an important role in the global eradication program and is crucial for monitoring silent PV circulation especially as clinical cases decrease. This study compared ES results using the novel bag-mediated filtration system (BMFS) with the current two-phase separation method. From February to November 2016, BMFS and two-phase samples were collected concurrently from twelve sites in Pakistan (n = 117). Detection was higher in BMFS than two-phase samples for each Sabin-like (SL) PV serotype (p<0.001) and wild PV type 1 (WPV1) (p = 0.065). Seventeen sampling events were positive for WPV1, with eight discordant in favor of BMFS and two in favor of two-phase. A vaccine-derived PV type 2 was detected in one BMFS sample but not the matched two-phase. After the removal of SL PV type 2 (SL2) from the oral polio vaccine in April 2016, BMFS samples detected SL2 more frequently than two-phase (p = 0.016), with the last detection by either method occurring June 12, 2016. More frequent PV detection in BMFS compared to two-phase samples is likely due to the greater effective volume assayed (1620 mL vs. 150 mL). This study demonstrated that the BMFS achieves enhanced ES for all PV serotypes in an endemic country.
Collapse
Affiliation(s)
- Nicolette Angela Zhou
- Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, WA, United States of America
| | - Christine Susan Fagnant-Sperati
- Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, WA, United States of America
| | - Jeffry Hiroshi Shirai
- Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, WA, United States of America
| | | | | | - Lubna Rehman
- National Institute of Health, Islamabad, Pakistan
| | | | - Rahim Agha
- World Health Organization, Islamabad, Pakistan
- National Emergency Operations Center, Islamabad, Pakistan
| | | | - Masroor Alam
- National Institute of Health, Islamabad, Pakistan
| | | | | | | | - Rana Muhammed Safdar
- National Institute of Health, Islamabad, Pakistan
- National Emergency Operations Center, Islamabad, Pakistan
| | - Abdirahman Mahamud
- World Health Organization, Islamabad, Pakistan
- National Emergency Operations Center, Islamabad, Pakistan
| | - Jamal Ahmed
- World Health Organization, Islamabad, Pakistan
- National Emergency Operations Center, Islamabad, Pakistan
| | - Sadaf Khan
- PATH, Seattle, WA, United States of America
| | - Alexandra Lynn Kossik
- Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, WA, United States of America
| | - Nicola Koren Beck
- Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, WA, United States of America
| | - Graciela Matrajt
- Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, WA, United States of America
| | | | | | | | - John Scott Meschke
- Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, WA, United States of America
| |
Collapse
|
160
|
Yue Y, Moe WM, Chen J, Wang J, Han J. Biofilter treatment of gas phase β-caryophyllene at an elevated temperature. J Environ Sci Health A Tox Hazard Subst Environ Eng 2018; 53:752-765. [PMID: 29553919 DOI: 10.1080/10934529.2018.1444969] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Experiments were carried out to test the capacity for a laboratory-scale biofilter operated at an elevated temperature level (∼50°C) to remove an air stream containing β-caryophyllene, a naturally occurring sesquiterpene of environmental concern emitted from wood-related industrial facilities. A water jacket was used to maintain high temperatures in a laboratory-scale biofilter. Inocula, pollutant loading and nutrient supply rate effects were evaluated over 84 days of biofilter operation. The start-up process took over two months when citrus peels were used as inocula while a relatively short start-up period was achieved after introducing forest compost products. While using a sparged-gas bioreactor to cultivate an enrichment culture for 97 days, removal efficiencies in excess of 80% were observed after 18 days. At empty bed contact times of 50 s and at a pollutant loading rate of 3.05 mg C/L/hr, removal efficiency levels reached 90% and the elimination capacity level reached 2.29 mg C/L/hr, corresponding to an elimination capacity of 2.60 mg β-caryophyllene/L/hr. Collectively, these results demonstrate that β-caryophyllene can be successfully removed from contaminated air using a biofilter operated at a high temperature (∼50°C), expanding the temperature range within which biofilters are known to biodegrade sesquiterpenes.
Collapse
Affiliation(s)
- Yiying Yue
- a College of Biology and the Environment , Nanjing Forestry University , Nanjing , Jiangsu , China
- b Department of Civil and Environmental Engineering , Louisiana State University , Baton Rouge , Louisiana , USA
| | - William M Moe
- b Department of Civil and Environmental Engineering , Louisiana State University , Baton Rouge , Louisiana , USA
| | - Jianqiang Chen
- a College of Biology and the Environment , Nanjing Forestry University , Nanjing , Jiangsu , China
| | - Jiao Wang
- c National Institute of Environmental Health , Chinese Center of Disease Prevention and Control , Beijing , China
| | - Jingquan Han
- d College of Material Science and Engineering , Nanjing Forestry University , Nanjing , Jiangsu , China
| |
Collapse
|
161
|
Pan X, Zhuo S, Zhong Q, Chen Y, Du W, Cheng H, Wang X, Zeng EY, Xing B, Tao S. A novel enhanced diffusion sampler for collecting gaseous pollutants without air agitation. J Environ Sci Health A Tox Hazard Subst Environ Eng 2018; 53:766-770. [PMID: 29509086 DOI: 10.1080/10934529.2018.1444973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
A novel enhanced diffusion sampler for collecting gaseous phase polycyclic aromatic hydrocarbons (PAHs) without air agitation is proposed. The diffusion of target compounds into a sampling chamber is facilitated by continuously purging through a closed-loop flow to create a large concentration difference between the ambient air and the air in the sampling chamber. A glass-fiber filter-based prototype was developed. It was demonstrated that the device could collect gaseous PAHs at a much higher rate (1.6 ± 1.4 L/min) than regular passive samplers, while the ambient air is not agitated. The prototype was also tested in both the laboratory and field for characterizing the concentration gradients over a short distance from the soil surface. The sampler has potential to be applied in other similar situations to characterize the concentration profiles of other chemicals.
Collapse
Affiliation(s)
- Xuelian Pan
- a College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes , Peking University , Beijing , China
| | - Shaojie Zhuo
- a College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes , Peking University , Beijing , China
| | - Qirui Zhong
- a College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes , Peking University , Beijing , China
| | - Yuanchen Chen
- a College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes , Peking University , Beijing , China
| | - Wei Du
- a College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes , Peking University , Beijing , China
| | - Hefa Cheng
- a College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes , Peking University , Beijing , China
| | - Xilong Wang
- a College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes , Peking University , Beijing , China
| | - Eddy Y Zeng
- b School of Environment, Guangzhou Key Laboratory of Environmental Exposure and Health and Guangdong Key Laboratory of Environmental Pollution and Health , Jinan University , Guangzhou , China
| | - Baoshan Xing
- c Stockbridge School of Agriculture , University of Massachusetts , Amherst , Massachusetts , USA
| | - Shu Tao
- a College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes , Peking University , Beijing , China
| |
Collapse
|
162
|
Su L, Du Q, Wang Y, Dong H, Gao J, Wang M, Dong P. Purification characteristics of fine particulate matter treated by a self-flushing wet electrostatic precipitator equipped with a flexible electrode. J Air Waste Manag Assoc 2018; 68:725-736. [PMID: 29652226 DOI: 10.1080/10962247.2018.1460635] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Revised: 03/20/2018] [Accepted: 03/26/2018] [Indexed: 06/08/2023]
Abstract
UNLABELLED A self-flushing wet electrostatic precipitator was developed to investigate the removal performance for fine particles. Flexible material (polypropylene, 840A) and carbon steel in the form of a spiked band were adopted as the collection plate and discharge electrode, respectively. The particle concentration, morphology, and trace-element content were measured by electric low-pressure impactor, scanning electron microscope, and energy-dispersive x-ray spectroscopy, respectively, before and after the electrostatic precipitator. With increasing gas velocity, the collection efficiency of fine particles (up to 0.8 μm in diameter) increased, while it decreased for particles with diameters larger than 0.8 μm. Increasing the dust inlet concentration increased the collection efficiency up to a point, from which it then declined gradually with further increases in the inlet concentration. The particulate matter after the wet electrostatic precipitator showed different degrees of agglomeration. The collection efficiency of trace elements within PM10 was less than that of the PM10 itself. Notably, the water consumption in the current setup was significantly lower than for other treatment processes of comparable collection efficiencies. IMPLICATIONS Wet electrostatic precipitators, as fine filtration equipment, were generally applicable to coal-fired plants to reduce PM2.5 emissions in China. However, high energy consumption and unstable operation, such as water usage and spray washing directly in the electric field, seriously restricted the further development. The utilization of self-flushing wet electrostatic precipitator can solve these problems to some extent.
Collapse
Affiliation(s)
- Lipeng Su
- a School of Energy Science and Engineering , Harbin Institute of Technology , Harbin , People's Republic of China
| | - Qian Du
- a School of Energy Science and Engineering , Harbin Institute of Technology , Harbin , People's Republic of China
| | - Yide Wang
- a School of Energy Science and Engineering , Harbin Institute of Technology , Harbin , People's Republic of China
- b College of Vehicles and Energy , Yanshan University , Qinhuangdao , People's Republic of China
| | - Heming Dong
- a School of Energy Science and Engineering , Harbin Institute of Technology , Harbin , People's Republic of China
| | - Jianmin Gao
- a School of Energy Science and Engineering , Harbin Institute of Technology , Harbin , People's Republic of China
| | - Min Wang
- a School of Energy Science and Engineering , Harbin Institute of Technology , Harbin , People's Republic of China
| | - Peng Dong
- a School of Energy Science and Engineering , Harbin Institute of Technology , Harbin , People's Republic of China
| |
Collapse
|
163
|
Chan S, Pullerits K, Riechelmann J, Persson KM, Rådström P, Paul CJ. Monitoring biofilm function in new and matured full-scale slow sand filters using flow cytometric histogram image comparison (CHIC). Water Res 2018; 138:27-36. [PMID: 29571086 DOI: 10.1016/j.watres.2018.03.032] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Revised: 03/09/2018] [Accepted: 03/12/2018] [Indexed: 06/08/2023]
Abstract
While slow sand filters (SSFs) have produced drinking water for more than a hundred years, understanding of their associated microbial communities is limited. In this study, bacteria in influent and effluent water from full-scale SSFs were explored using flow cytometry (FCM) with cytometric histogram image comparison (CHIC) analysis; and routine microbial counts for heterotrophs, total coliforms and Escherichia coli. To assess if FCM can monitor biofilm function, SSFs differing in age and sand composition were compared. FCM profiles from two established filters were indistinguishable. To examine biofilm in the deep sand bed, SSFs were monitored during a scraping event, when the top layer of sand and the schmutzdecke are removed to restore flow through the filter. The performance of an established SSF was stable: total organic carbon (TOC), pH, numbers of heterotrophs, coliforms, E. coli, and FCM bacterial profile were unaffected by scraping. However, the performance of two newly-built SSFs containing new and mixed sand was compromised: breakthrough of both microbial indicators and TOC occurred following scraping. The compromised performance of the new SSFs was reflected in distinct effluent bacterial communities; and, the presence of microbial indicators correlated to influent bacterial communities. This demonstrated that FCM can monitor SSF performance. Removal of the top layer of sand did not alter the effluent water from the established SSF, but did affect that of the SSFs containing new sand. This suggests that the impact of the surface biofilm on effluent water is greater when the deep sand bed biofilm is not established.
Collapse
Affiliation(s)
- Sandy Chan
- Applied Microbiology, Department of Chemistry, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden; Sweden Water Research AB, Ideon Science Park, Scheelevägen 15, SE-223 70 Lund, Sweden; Sydvatten AB, Hyllie Stationstorg 21, SE-215 32 Malmö, Sweden.
| | - Kristjan Pullerits
- Applied Microbiology, Department of Chemistry, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden; Sweden Water Research AB, Ideon Science Park, Scheelevägen 15, SE-223 70 Lund, Sweden; Sydvatten AB, Hyllie Stationstorg 21, SE-215 32 Malmö, Sweden.
| | - Janine Riechelmann
- Applied Microbiology, Department of Chemistry, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden.
| | - Kenneth M Persson
- Sweden Water Research AB, Ideon Science Park, Scheelevägen 15, SE-223 70 Lund, Sweden; Sydvatten AB, Hyllie Stationstorg 21, SE-215 32 Malmö, Sweden; Water Resources Engineering, Department of Building and Environmental Technology, Lund University, P.O. Box 118, SE-221 00 Lund, Sweden.
| | - Peter Rådström
- Applied Microbiology, Department of Chemistry, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden.
| | - Catherine J Paul
- Applied Microbiology, Department of Chemistry, Lund University, P.O. Box 124, SE-221 00 Lund, Sweden; Water Resources Engineering, Department of Building and Environmental Technology, Lund University, P.O. Box 118, SE-221 00 Lund, Sweden.
| |
Collapse
|
164
|
Sempere F, Winter P, Waalkens A, Hühnert N, Cranshaw I, Beigi B, Thorpe RB. Treatment of discontinuous emission of sewage sludge odours by a full scale biotrickling filter with an activated carbon polishing unit. Water Sci Technol 2018; 77:2482-2490. [PMID: 29893737 DOI: 10.2166/wst.2018.203] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
A SULPHUSTM biotrickling filter (BTF) and an ACTUSTM polishing activated carbon filter (ACF) were used at a wastewater treatment plant to treat 2,432 m3·h-1 of air extracted from sewage sludge processes. The project is part of Thames Water's strategy to reduce customer odour impact and, in this case, is designed to achieve a maximum discharge concentration of 1,000 ouE·m-3. The odour and hydrogen sulphide concentration in the input air was more influenced by the operation of the sludge holding tank mixers than by ambient temperature. Phosphorus was found to be limiting the performance of the BTF during peak conditions, hence requiring additional nutrient supply. Olfactometry and pollutant measurements demonstrated that during the high rate of change of intermittent odour concentrations the ACF was required to reach compliant stack values. The two stage unit outperformed design criteria, with 139 ouE·m-3 measured after 11 months of operation. At peak conditions and even at very low temperatures, the nutrient addition considerably increased the performance of the BTF, extending the time before activated carbon replacement over the one year design time. During baseline operation, the BTF achieved values between 266-1,647 ouE·m-3 even during a 6 day irrigation failure of the biofilm.
Collapse
Affiliation(s)
- F Sempere
- Pure Air Solutions, P.O. Box 135, Heerenveen 8440 AC, The Netherlands
| | - P Winter
- Thames Water, Innovation Centre, Reading STW, Island Rd, Reading RG6 0RP, UK
| | - A Waalkens
- Pure Air Solutions, P.O. Box 135, Heerenveen 8440 AC, The Netherlands
| | - N Hühnert
- Thames Water, Innovation Centre, Reading STW, Island Rd, Reading RG6 0RP, UK
| | - I Cranshaw
- MWH UK Ltd (Part of Stantec), Buckingham Court, Kingsmead Business Park, London Road, High Wycombe HP11 1JU, UK
| | - B Beigi
- Department of Chemical and Process Engineering, University of Surrey, Guildford GU2 7XH, UK
| | - R B Thorpe
- Department of Chemical and Process Engineering, University of Surrey, Guildford GU2 7XH, UK
| |
Collapse
|
165
|
Déon S, Lam B, Fievet P. Application of a new dynamic transport model to predict the evolution of performances throughout the nanofiltration of single salt solutions in concentration and diafiltration modes. Water Res 2018; 136:22-33. [PMID: 29494894 DOI: 10.1016/j.watres.2018.02.038] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Revised: 02/13/2018] [Accepted: 02/16/2018] [Indexed: 06/08/2023]
Abstract
Although many knowledge models describing the rejection of ionic compounds by nanofiltration membranes are available in literature, they are all used in full recycling mode. Indeed, both permeate and retentate streams are recycled in order to maintain constant concentrations in the feed solution. However, nanofiltration of real effluents is implemented either in concentration or diafiltration modes, for which the permeate stream is collected. In these conditions, concentrations progressively evolve during filtration and classical models fail to predict performances. In this paper, an improvement of the so called "Donnan Steric Pore Model", which includes both volume and concentration variations over time is proposed. This dynamic model is used here to predict the evolution of volumes and concentrations in both permeate and retentate streams during the filtration of salt solutions. This model was found to predict accurately the filtration performances with various salts whether the filtration is performed in concentration or diafiltration modes. The parameters of the usual model can be easily assessed from full batch experiments before being used in the dynamic version. Nevertheless, it is also highlighted that the variation of the membrane charge due to the evolution of feed concentration over time has to be taken into account in the model through the use of adsorption isotherms.
Collapse
Affiliation(s)
- Sébastien Déon
- Institut UTINAM (UMR CNRS 6213), Université de Bourgogne Franche-Comté, 16 route de Gray, 25030, Besançon cedex, France.
| | - Boukary Lam
- Institut UTINAM (UMR CNRS 6213), Université de Bourgogne Franche-Comté, 16 route de Gray, 25030, Besançon cedex, France
| | - Patrick Fievet
- Institut UTINAM (UMR CNRS 6213), Université de Bourgogne Franche-Comté, 16 route de Gray, 25030, Besançon cedex, France
| |
Collapse
|
166
|
Shammay A, Evanson I, Stuetz RM. A comparison of removal performance of volatile organic and sulfurous compounds between odour abatement systems. Water Sci Technol 2018; 77:2657-2667. [PMID: 29944130 DOI: 10.2166/wst.2018.223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Three types of odour abatement systems in sewer networks in Australia were studied for 18 months to determine the removals of different compounds. Six volatile sulfurous compounds and seven volatile organic compounds (VOCs) were further investigated. All types of odour abatement systems exhibited good removal of hydrogen sulfide with the biotrickling filters (BTFs) showing the highest consistent removal. Biofilters outperformed BTFs and activated carbon (AC) filters in the removal of dimethyl mono-, di- and tri-sulfide species at the low inlet concentrations typically found. AC filters exhibited little VOC removal with no compound consistently identified as having a removal greater than 0%. Biofilters outperformed BTFs in VOC removal, yet both had high removal variability.
Collapse
Affiliation(s)
- A Shammay
- School of Civil and Environmental Engineering, UNSW, Sydney, NSW, Australia E-mail: ; Stantec Australia, North Sydney, NSW, Australia
| | - I Evanson
- Stantec Australia, North Sydney, NSW, Australia
| | - R M Stuetz
- School of Civil and Environmental Engineering, UNSW, Sydney, NSW, Australia E-mail:
| |
Collapse
|
167
|
Sawadogo B, Konaté Y, Lesage G, Zaviska F, Monnot M, Heran M, Karambiri H. Brewery wastewater treatment using MBR coupled with nanofiltration or electrodialysis: biomass acclimation and treatment efficiency. Water Sci Technol 2018; 77:2624-2634. [PMID: 29944127 DOI: 10.2166/wst.2018.232] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Breweries release significant amounts of wastewater loaded with various organic and mineral materials. Prior studies of membrane bioreactor (MBR) wastewater treatment have been conducted with very little interest granted to the conditions of biomass acclimation. This study displays biomass behavior during brewery wastewater treatment by an aerobic MBR. In addition, nanofiltration and electrodialysis have been studied as potential post-treatment to decrease mineral concentrations and permit further water reuse for agriculture. An anoxic/aerobic laboratory MBR, associated with a flat sulfonated polyether membrane was used for synthetic brewery wastewater treatment. Biomass acclimation was performed using a feeding substrate. Organic concentrations in the MBR influent varied from 700 mg COD/L to 10,600 mg COD/L (COD: chemical oxygen demand) for 110 days. The results indicate a good acclimation to effluent with high salts and organic matter loads. Steady evolution of biomass concentration and activities was achieved after 90 days of operation. A reduction of COD of around 95% was obtained with MBR and up to 99% with nanofiltration post-treatment for the reconstructed brewery effluent with an organic loading rate of 7 g COD/L·d and a solid and hydraulic retention time of 30 days and 36 hours. A good reduction of the salt content was also recorded primarily with the nanofiltration and electrodialysis processes.
Collapse
Affiliation(s)
- B Sawadogo
- Water Depollution Ecosystems and Health Laboratory (LEDES), International Institute for Water and Environmental Engineering (2iE), 1 Rue de la science, 01 BP 594, Ouagadougou, Burkina Faso E-mail:
| | - Y Konaté
- Water Depollution Ecosystems and Health Laboratory (LEDES), International Institute for Water and Environmental Engineering (2iE), 1 Rue de la science, 01 BP 594, Ouagadougou, Burkina Faso E-mail:
| | - G Lesage
- Institut Européen des Membranes, IEM - UMR 5635, ENSCM, CNRS, Université de Montpellier, Montpellier, France
| | - F Zaviska
- Institut Européen des Membranes, IEM - UMR 5635, ENSCM, CNRS, Université de Montpellier, Montpellier, France
| | - M Monnot
- Institut Européen des Membranes, IEM - UMR 5635, ENSCM, CNRS, Université de Montpellier, Montpellier, France
| | - M Heran
- Institut Européen des Membranes, IEM - UMR 5635, ENSCM, CNRS, Université de Montpellier, Montpellier, France
| | - H Karambiri
- Water Depollution Ecosystems and Health Laboratory (LEDES), International Institute for Water and Environmental Engineering (2iE), 1 Rue de la science, 01 BP 594, Ouagadougou, Burkina Faso E-mail:
| |
Collapse
|
168
|
Man K, Zhu Q, Guo Z, Xing Z. Fe-Ti/Fe (II)-loading on ceramic filter materials for residual chlorine removal from drinking water. Chemosphere 2018; 200:405-411. [PMID: 29499521 DOI: 10.1016/j.chemosphere.2018.02.156] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2017] [Revised: 02/18/2018] [Accepted: 02/25/2018] [Indexed: 06/08/2023]
Abstract
Ceramic filter material was prepared with silicon dioxide (SiO2), which was recovered from red mud and then modified with Fe (II) and Fe-Ti bimetal oxide. Ceramic filter material can be used to reduce the content of residual chlorine from drinking water. The results showed that after a two-step leaching process with 3 M hydrochloric acid (HCl) and 90% sulfuric acid (H2SO4), the recovery of SiO2 exceeded 80%. Fe (II)/Fe-Ti bimetal oxide, with a high adsorption capacity of residual chlorine, was prepared using a 3:1 M ratio of Fe/Ti and a concentration of 0.4 mol/L Fe2+. According to the zeta-potential, scanning electron microscopy (SEM) and Brunauer-Emmett-Teller (BET) analysis, Fe (II) and Fe-Ti bimetal oxide altered the zeta potential and structural properties of the ceramic filter material. There was a synergistic interaction between Fe and Ti in which FeOTi bonds on the material surface and hydroxyl groups provided the active sites for adsorption. Through a redox reaction, Fe (II) transfers hypochlorite to chloride, and FeOTiCl bonds were formed after adsorption.
Collapse
Affiliation(s)
- Kexin Man
- School of Chemistry and Materials Science, Heilongjiang University, Key Laboratory of Chemical Engineering Process & Technology for High-efficiency Conversion, Harbin 150080, China
| | - Qi Zhu
- School of Chemistry and Materials Science, Heilongjiang University, Key Laboratory of Chemical Engineering Process & Technology for High-efficiency Conversion, Harbin 150080, China.
| | - Zheng Guo
- School of Chemistry and Materials Science, Heilongjiang University, Key Laboratory of Chemical Engineering Process & Technology for High-efficiency Conversion, Harbin 150080, China
| | - Zipeng Xing
- School of Chemistry and Materials Science, Heilongjiang University, Key Laboratory of Chemical Engineering Process & Technology for High-efficiency Conversion, Harbin 150080, China.
| |
Collapse
|
169
|
Zheng X, Zhang S, Zhang J, Huang D, Zheng Z. Advanced nitrogen removal from municipal wastewater treatment plant secondary effluent using a deep bed denitrification filter. Water Sci Technol 2018; 77:2723-2732. [PMID: 29944137 DOI: 10.2166/wst.2018.231] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
With the improvement of wastewater discharge standards, wastewater treatment plants (WWTPs) are continually undergoing technological improvements to meet the evolving standards. In this study, a quartz sand deep bed denitrification filter (DBDF) was used to purify WWTP secondary effluent, utilizing high nitrate nitrogen concentrations and a low C/N ratio. Results show that more than 90% of nitrate nitrogen (NO3-N) and 75% of chemical oxygen demand (COD) could be removed by the 20th day of filtration. When the filter layer depth was set to 1,600 mm and the additional carbon source CH3OH was maintained at 30 mg L-1 COD (20 mg L-1 methanol), the total nitrogen (TN) and COD concentrations of DBDF effluent were stabilized below 5 and 30 mg L-1, respectively. Analysis of fluorescence revealed that DBDF had a stronger effect on the removal of dissolved organic matter (DOM), especially of aromatic protein-like substances. High throughput sequencing and qPCR results indicate a distinctly stratified microbial distribution for the main functional species in DBDF, with quartz sand providing a good environment for microbes. The phyla Proteobacteria, Bacteroidetes, and Chloroflexi were found to be the dominant species in DBDF.
Collapse
Affiliation(s)
- Xiaowei Zheng
- Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China E-mail:
| | - Shenyao Zhang
- Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China E-mail:
| | - Jibiao Zhang
- Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China E-mail:
| | - Deying Huang
- Department of Chemistry, Fudan University, Shanghai 200433, China
| | - Zheng Zheng
- Department of Environmental Science and Engineering, Fudan University, Shanghai 200433, China E-mail:
| |
Collapse
|
170
|
Nriagu J, Xi C, Siddique A, Vincent A, Shomar B. Influence of Household Water Filters on Bacteria Growth and Trace Metals in Tap Water of Doha, Qatar. Sci Rep 2018; 8:8268. [PMID: 29844504 PMCID: PMC5974232 DOI: 10.1038/s41598-018-26529-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Accepted: 04/30/2018] [Indexed: 12/17/2022] Open
Abstract
Deteriorating water quality from aging infrastructure, growing threat of pollution from industrialization and urbanization, and increasing awareness about waterborne diseases are among the factors driving the surge in worldwide use of point-of-entry (POE) and point-of-use (POU) filters. Any adverse influence of such consumer point-of-use systems on quality of water at the tap remains poorly understood, however. We determined the chemical and microbiological changes in municipal water from the point of entry into the household plumbing system until it leaves from the tap in houses equipped with filters. We show that POE/POU devices can induce significant deterioration of the quality of tap water by functioning as traps and reservoirs for sludge, scale, rust, algae or slime deposits which promote microbial growth and biofilm formation in the household water distribution system. With changes in water pressure and physical or chemical disturbance of the plumbing system, the microorganisms and contaminants may be flushed into the tap water. Such changes in quality of household water carry a potential health risk which calls for some introspection in widespread deployment of POE/POU filters in water distribution systems.
Collapse
Affiliation(s)
- Jerome Nriagu
- Department of Environmental Health Sciences, School of Public Health, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Chuanwu Xi
- Department of Environmental Health Sciences, School of Public Health, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Azhar Siddique
- Unit for Ain-Zibaida and Groundwater Rehabilitation, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Annette Vincent
- Biological Sciences Program, Carnegie Mellon University in Qatar, Qatar, Saudi Arabia
| | - Basem Shomar
- Qatar Environmental & Energy Research Institute, Hamad bin Khalifa University, Doha, Qatar, Saudi Arabia.
| |
Collapse
|
171
|
Abstract
BACKGROUND An intraocular lens (IOL) is a synthetic lens that is surgically implanted within the eye following removal of the crystalline lens, during cataract surgery. While all modern IOLs attenuate the transmission of ultra-violet (UV) light, some IOLs, called blue-blocking or blue-light filtering IOLs, also reduce short-wavelength visible light transmission. The rationale for blue-light filtering IOLs derives primarily from cell culture and animal studies, which suggest that short-wavelength visible light can induce retinal photoxicity. Blue-light filtering IOLs have been suggested to impart retinal protection and potentially prevent the development and progression of age-related macular degeneration (AMD). We sought to investigate the evidence relating to these suggested benefits of blue-light filtering IOLs, and to consider any potential adverse effects. OBJECTIVES To assess the effects of blue-light filtering IOLs compared with non-blue-light filtering IOLs, with respect to providing protection to macular health and function. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2017, Issue 9); Ovid MEDLINE; Ovid Embase; LILACS; the ISRCTN registry; ClinicalTrials.gov and the ICTRP. The date of the search was 25 October 2017. SELECTION CRITERIA We included randomised controlled trials (RCTs), involving adult participants undergoing cataract extraction, where a blue-light filtering IOL was compared with an equivalent non-blue-light filtering IOL. DATA COLLECTION AND ANALYSIS The prespecified primary outcome was the change in distance best-corrected visual acuity (BCVA), as a continuous outcome, between baseline and 12 months of follow-up. Prespecified secondary outcomes included postoperative contrast sensitivity, colour discrimination, macular pigment optical density (MPOD), proportion of eyes with a pathological finding at the macula (including, but not limited to the development or progression of AMD, or both), daytime alertness, reaction time and patient satisfaction. We evaluated findings related to ocular and systemic adverse effects.Two review authors independently screened abstracts and full-text articles, extracted data from eligible RCTs and judged the risk of bias using the Cochrane tool. We reached a consensus on any disagreements by discussion. Where appropriate, we pooled data relating to outcomes and used random-effects or fixed-effect models for the meta-analyses. We summarised the overall certainty of the evidence using GRADE. MAIN RESULTS We included 51 RCTs from 17 different countries, although most studies either did not report relevant outcomes, or provided data in a format that could not be extracted. Together, the included studies considered the outcomes of IOL implantation in over 5000 eyes. The number of participants ranged from 13 to 300, and the follow-up period ranged from one month to five years. Only two of the studies had a trial registry record and no studies referred to a published protocol. We did not judge any of the studies to have a low risk of bias in all seven domains. We judged approximately two-thirds of the studies to have a high risk of bias in domains relating to 'blinding of participants and personnel' (performance bias) and 'blinding of outcome assessment' (detection bias).We found with moderate certainty, that distance BCVA with a blue-light filtering IOL, at six to 18 months postoperatively, and measured in logMAR, was not clearly different to distance BCVA with a non-blue-light filtering IOL (mean difference (MD) -0.01 logMAR, 95% confidence interval (CI) -0.03 to 0.02, P = 0.48; 2 studies, 131 eyes).There was very low-certainty evidence relating to any potential inter-intervention difference for the proportion of eyes that developed late-stage AMD at three years of follow-up, or any stage of AMD at one year of follow-up, as data derived from one trial and two trials respectively, and there were no events in either IOL intervention group, for either outcome. There was very low-certainty evidence for the outcome for the proportion of participants who lost 15 or more letters of distance BCVA at six months of follow-up; two trials that considered a total of 63 eyes reported no events, in either IOL intervention group.There were no relevant, combinable data available for outcomes relating to the effect on contrast sensitivity at six months, the proportion of eyes with a measurable loss of colour discrimination from baseline at six months, or the proportion of participants with adverse events with a probable causal link with the study interventions after six months.We were unable to draw reliable conclusions on the relative equivalence or superiority of blue-light filtering IOLs versus non-blue-light filtering IOLs in relation to longer-term effects on macular health. We were also not able to determine with any certainty whether blue-light filtering IOLs have any significant effects on MPOD, contrast sensitivity, colour discrimination, daytime alertness, reaction time or patient satisfaction, relative to non-blue-light filtering IOLs. AUTHORS' CONCLUSIONS This systematic review shows with moderate certainty that there is no clinically meaningful difference in short-term BCVA with the two types of IOLs. Further, based upon available data, these findings suggest that there is no clinically meaningful difference in short-term contrast sensitivity with the two interventions, although there was a low level of certainty for this outcome due to a small number of included studies and their inherent risk of bias. Based upon current, best-available research evidence, it is unclear whether blue-light filtering IOLs preserve macular health or alter risks associated with the development and progression of AMD, or both. Further research is required to fully understand the effects of blue-light filtering IOLs for providing protection to macular health and function.
Collapse
Affiliation(s)
- Laura E Downie
- The University of MelbourneDepartment of Optometry and Vision SciencesLevel 4, Alice Hoy BuildingParkvilleVictoriaAustralia3010
| | - Ljoudmila Busija
- Australian Catholic UniversityInstitute for Health and Ageing215 Spring StreetMelbourneVictoriaAustralia3000
| | - Peter R Keller
- The University of MelbourneDepartment of Optometry and Vision SciencesLevel 4, Alice Hoy BuildingParkvilleVictoriaAustralia3010
| | | |
Collapse
|
172
|
Thornhill SG, Kumar M. Biological filters and their use in potable water filtration systems in spaceflight conditions. Life Sci Space Res (Amst) 2018; 17:40-43. [PMID: 29753412 DOI: 10.1016/j.lssr.2018.03.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2017] [Revised: 02/16/2018] [Accepted: 03/04/2018] [Indexed: 06/08/2023]
Abstract
Providing drinking water to space missions such as the International Space Station (ISS) is a costly requirement for human habitation. To limit the costs of water transport, wastewater is collected and purified using a variety of physical and chemical means. To date, sand-based biofilters have been designed to function against gravity, and biofilms have been shown to form in microgravity conditions. Development of a universal silver-recycling biological filter system that is able to function in both microgravity and full gravity conditions would reduce the costs incurred in removing organic contaminants from wastewater by limiting the energy and chemical inputs required. This paper aims to propose the use of a sand-substrate biofilter to replace chemical means of water purification on manned spaceflights.
Collapse
Affiliation(s)
- Starla G Thornhill
- Department of Biology, Texas State University, San Marcos, TX 78666, USA.
| | - Manish Kumar
- Department of Biology, Texas State University, San Marcos, TX 78666, USA.
| |
Collapse
|
173
|
Loukas CM, Mowlem MC, Tsaloglou MN, Green NG. A novel portable filtration system for sampling and concentration of microorganisms: Demonstration on marine microalgae with subsequent quantification using IC-NASBA. Harmful Algae 2018; 75:94-104. [PMID: 29778229 DOI: 10.1016/j.hal.2018.03.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Revised: 03/19/2018] [Accepted: 03/24/2018] [Indexed: 06/08/2023]
Abstract
This paper presents a novel portable sample filtration/concentration system, designed for use on samples of microorganisms with very low cell concentrations and large volumes, such as water-borne parasites, pathogens associated with faecal matter, or toxic phytoplankton. The example application used for demonstration was the in-field collection and concentration of microalgae from seawater samples. This type of organism is responsible for Harmful Algal Blooms (HABs), an example of which is commonly referred to as "red tides", which are typically the result of rapid proliferation and high biomass accumulation of harmful microalgal species in the water column or at the sea surface. For instance, Karenia brevis red tides are the cause of aquatic organism mortality and persistent blooms may cause widespread die-offs of populations of other organisms including vertebrates. In order to respond to, and adequately manage HABs, monitoring of toxic microalgae is required and large-volume sample concentrators would be a useful tool for in situ monitoring of HABs. The filtering system presented in this work enables consistent sample collection and concentration from 1 L to 1 mL in five minutes, allowing for subsequent benchtop sample extraction and analysis using molecular methods such as NASBA and IC-NASBA. The microalga Tetraselmis suecica was successfully detected at concentrations ranging from 2 × 105 cells/L to 20 cells/L. Karenia brevis was also detected and quantified at concentrations between 10 cells/L and 106 cells/L. Further analysis showed that the filter system, which concentrates cells from very large volumes with consequently more reliable sampling, produced samples that were more consistent than the independent non-filtered samples (benchtop controls), with a logarithmic dependency on increasing cell numbers. This filtering system provides simple, rapid, and consistent sample collection and concentration for further analysis, and could be applied to a wide range of different samples and target organisms in situations lacking laboratories.
Collapse
Affiliation(s)
- Christos-Moritz Loukas
- National Oceanography Centre (NOC), University of Southampton Waterfront Campus, European Way, Southampton, SO14 3ZH, United Kingdom; Department of Ocean and Earth Science, University of Southampton Waterfront Campus, European Way, Southampton, SO14 3ZH, United Kingdom.
| | - Matthew C Mowlem
- National Oceanography Centre (NOC), University of Southampton Waterfront Campus, European Way, Southampton, SO14 3ZH, United Kingdom.
| | - Maria-Nefeli Tsaloglou
- National Oceanography Centre (NOC), University of Southampton Waterfront Campus, European Way, Southampton, SO14 3ZH, United Kingdom; Department of Ocean and Earth Science, University of Southampton Waterfront Campus, European Way, Southampton, SO14 3ZH, United Kingdom; Institute for Life Sciences, University of Southampton Highfield Campus, Highfield, Southampton, SO17 1BJ, United Kingdom.
| | - Nicolas G Green
- Institute for Life Sciences, University of Southampton Highfield Campus, Highfield, Southampton, SO17 1BJ, United Kingdom; School of Electronics and Computer Science (ECS), University of Southampton Highfield Campus, Highfield, Southampton, SO17 1BJ, United Kingdom.
| |
Collapse
|
174
|
Hott RC, Maia LFO, Santos MS, Faria MC, Oliveira LCA, Pereira MC, Bomfeti CA, Rodrigues JL. Purification of arsenic-contaminated water with K-jarosite filters. Environ Sci Pollut Res Int 2018; 25:13857-13867. [PMID: 29512010 DOI: 10.1007/s11356-018-1344-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Accepted: 01/22/2018] [Indexed: 06/08/2023]
Abstract
The high toxicity and potential arsenic accumulation in several environments have encouraged the development of technologies for its removal from contaminated waters. However, the arsenic released into aquatic environment comes mainly from extremely acidic mining effluents, making harder to find stable adsorbents to be used in these conditions. In this work, K-jarosite particles were synthesized as a stable adsorbent in acidic medium for eliminating arsenic from contaminated water. The adsorption capacities of K-jarosite for As3+, As5+, and monomethylarsonic acid were 9.45, 12.36, and 8.21 mg g-1, respectively. Most arsenic in water was adsorbed within the first 10 min, suggesting the fast arsenic adsorption kinetics of K-jarosite particles. Because of that, a K-jarosite filter was constructed for purifying water at a constant flow. The K-jarosite filter was highly efficient to treat arsenic-contaminated water from a Brazilian river, reducing the concentration of arsenic in water to near zero. These data suggest the K-jarosite filter can be used as a low-cost technology for purifying arsenic-contaminated water in acidic medium.
Collapse
Affiliation(s)
- Rodrigo C Hott
- Instituto de Ciência, Engenharia e Tecnologia (ICET), Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Teófilo Otoni, Minas Gerais, 39803-371, Brazil
| | - Luiz F O Maia
- Instituto de Ciência, Engenharia e Tecnologia (ICET), Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Teófilo Otoni, Minas Gerais, 39803-371, Brazil
| | - Mayra S Santos
- Instituto de Ciência, Engenharia e Tecnologia (ICET), Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Teófilo Otoni, Minas Gerais, 39803-371, Brazil
| | - Márcia C Faria
- Instituto de Ciência, Engenharia e Tecnologia (ICET), Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Teófilo Otoni, Minas Gerais, 39803-371, Brazil
| | - Luiz C A Oliveira
- Departamento de Química, ICEx, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, 31270-901, Brazil
| | - Márcio C Pereira
- Instituto de Ciência, Engenharia e Tecnologia (ICET), Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Teófilo Otoni, Minas Gerais, 39803-371, Brazil
| | - Cleide A Bomfeti
- Instituto de Ciência, Engenharia e Tecnologia (ICET), Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Teófilo Otoni, Minas Gerais, 39803-371, Brazil
| | - Jairo L Rodrigues
- Instituto de Ciência, Engenharia e Tecnologia (ICET), Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Teófilo Otoni, Minas Gerais, 39803-371, Brazil.
| |
Collapse
|
175
|
Morris JF, Murphy J, Fagerli K, Schneeberger C, Jaron P, Moke F, Juma J, Ochieng JB, Omore R, Roellig D, Xiao L, Priest JW, Narayanan J, Montgomery JM, Hill V, Mintz E, Ayers TL, O’Reilly CE. A Randomized Controlled Trial to Assess the Impact of Ceramic Water Filters on Prevention of Diarrhea and Cryptosporidiosis in Infants and Young Children-Western Kenya, 2013. Am J Trop Med Hyg 2018; 98:1260-1268. [PMID: 29611500 PMCID: PMC5953370 DOI: 10.4269/ajtmh.17-0731] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Accepted: 02/07/2018] [Indexed: 11/07/2022] Open
Abstract
Cryptosporidium is a leading cause of diarrhea among Kenyan infants. Ceramic water filters (CWFs) are used for household water treatment. We assessed the impact of CWFs on diarrhea, cryptosporidiosis prevention, and water quality in rural western Kenya. A randomized, controlled intervention trial was conducted in 240 households with infants 4-10 months old. Twenty-six weekly household surveys assessed infant diarrhea and health facility visits. Stool specimens from infants with diarrhea were examined for Cryptosporidium. Source water, filtered water, and filter retentate were tested for Cryptosporidium and/or microbial indicators. To estimate the effect of CWFs on health outcomes, logistic regression models using generalized estimating equations were performed; odds ratios (ORs) and 95% confidence intervals (CIs) are reported. Households reported using surface water (36%), public taps (29%), or rainwater (17%) as their primary drinking water sources, with no differences in treatment groups. Intervention households reported less diarrhea (7.6% versus 8.9%; OR: 0.86 [0.64-1.16]) and significantly fewer health facility visits for diarrhea (1.0% versus 1.9%; OR: 0.50 [0.30-0.83]). In total, 15% of intervention and 12% of control stools yielded Cryptosporidium (P = 0.26). Escherichia coli was detected in 93% of source water samples; 71% of filtered water samples met World Health Organization recommendations of < 1 E. coli/100 mL. Cryptosporidium was not detected in source water and was detected in just 2% of filter rinses following passage of large volumes of source water. Water quality was improved among CWF users; however, the short study duration and small sample size limited our ability to observe reductions in cryptosporidiosis.
Collapse
Affiliation(s)
- Jamae Fontain Morris
- Epidemic Intelligence Service, Centers for Disease Control and Prevention, Atlanta, Georgia
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
- Department of African-American Studies, Georgia State University, Atlanta, Georgia
| | - Jennifer Murphy
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Kirsten Fagerli
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Chandra Schneeberger
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Peter Jaron
- Kenya Medical Research Institute, Center for Global Health Research, Kisumu, Kenya
| | - Fenny Moke
- Kenya Medical Research Institute, Center for Global Health Research, Kisumu, Kenya
| | - Jane Juma
- Kenya Medical Research Institute, Center for Global Health Research, Kisumu, Kenya
| | - John B. Ochieng
- Kenya Medical Research Institute, Center for Global Health Research, Kisumu, Kenya
| | - Richard Omore
- Kenya Medical Research Institute, Center for Global Health Research, Kisumu, Kenya
| | - Dawn Roellig
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Lihua Xiao
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Jeffrey W. Priest
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Jothikumar Narayanan
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
| | | | - Vince Hill
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Eric Mintz
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Tracy L. Ayers
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Ciara E. O’Reilly
- Division of Foodborne, Waterborne and Environmental Diseases, National Center for Emerging and Zoonotic Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia
| |
Collapse
|
176
|
Hogue MG, Gause-Lott SM, Owensby BN, Slack TM, Smiley JJ, Burkett JL. Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set. Health Phys 2018; 114:479-485. [PMID: 29505432 DOI: 10.1097/hp.0000000000000800] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dust loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. A linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm to 1,000 mg cm.
Collapse
Affiliation(s)
- M G Hogue
- *Savannah River Nuclear Solutions, LLC, Bldg. 730-1B Rm. 108, Aiken, SC 29808
| | | | | | | | | | | |
Collapse
|
177
|
Helling A, König H, Seiler F, Berkholz R, Thom V, Polakovic M. Retention of Acholeplasma laidlawii by Sterile Filtration Membranes: Effect of Cultivation Medium and Filtration Temperature. PDA J Pharm Sci Technol 2018; 72:264-277. [PMID: 29343618 DOI: 10.5731/pdajpst.2017.008102] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
UNLABELLED This experimental study compares cell size, zeta potential, and the ability to penetrate tailor-made size exclusion membrane filters of mycoplasma Acholeplasma laidlawii cultivated in five different cultivation media. The influence of relevant filtration process parameters, in particular transmembrane pressure and filtration temperature, on their respective retention was tested. The impact of the filtration temperature was further evaluated for the Gram-negative bacteria species Brevundimonas diminuta, the Gram-positive bacteria species Staphylococcus epidermidis, the Pseudomonas phage PP7, and the mycoplasma species Mycoplasma orale The findings were correlated to the different mechanical properties of the particles, especially also with respect to the different bacterial cell envelopes found in those species. This study suggests that mycoplasma, surrounded by a flexible lipid bilayer, are significantly susceptible to changes in temperature, altering the stiffness of the cell envelope. Mycoplasma retention could thus be increased significantly by a decreased filtration temperature. In contrast, Gram-negative and Gram-positive bacteria species, with a cell wall containing a cross-linked peptidoglycan layer, as well as bacteriophages PP7 exhibiting a rigid protein capsid, did not show a temperature-dependent retention within the applied filtration temperatures between 2 and 35 °C. The trends of the retention of A. laidlawii with increasing temperature and transmembrane pressure were independent of cultivation media. Data obtained with mycoplasma M. orale suggest that the trend of mycoplasma retention at different filtration temperatures is also independent of the membrane pore size and thus retention level.LAY ABSTRACT: Media in biopharmaceutical processes are sterile-filtered to prevent them from bacterial contamination. Mycoplasma represent a relevant class of bacteria. In this publication it is shown that mycoplasma cell size depends on the media they are cultivated in. Membranes used for sterile filtration retain bacteria predominantly by size exclusion. Thus, an altered cell size can result in different retention values. Another characteristic of mycoplasma is the flexible lipid bilayer and the absence of a rigid cell wall. The lipid bilayer can undergo a phase transition from a gel to a liquid-crystal phase at a certain temperature, which makes it stiffer at lower temperatures. A higher stiffness can result in higher retention values during filtration, as the deformability of the mycoplasma cell is lower and the cell does not squeeze through the membrane pores. ABBREVIATIONS ALCM: A. laidlawii culture medium; ASTM: American Society for Testing and Materials; ATCC: American Type Culture Collection; CFU/mL: colony-forming units per milliliter; DLS: Dynamic light scattering; LRV: Log reduction value; PES: Polyethersulfone; PFU/mL: Plaque-forming units per milliliter; PSD: Particle size distribution; PVP: Polyvinylpyrrolidone; SDS: Sodium dodecyl sulfate; SEM: Scanning electron microscopy; SLB: Saline lactose broth; TMP: Transmembrane pressure; TSB: Tryptic soy broth.
Collapse
Affiliation(s)
- Alexander Helling
- Sartorius Stedim Biotech GmbH, Göttingen, Germany;
- Department of Chemical and Biochemical Engineering, Institute of Chemical and Environmental Engineering, Faculty of Chemical and Food Technology, Slovak University of Technology, Bratislava, Slovakia
| | - Hannes König
- Department of Medical Engineering and Biotechnology, University of Applied Science Jena, Jena, Germany; and
| | - Felix Seiler
- Faculty of Natural Sciences, University of Applied Sciences Esslingen, Esslingen, Germany
| | - Ralph Berkholz
- Department of Medical Engineering and Biotechnology, University of Applied Science Jena, Jena, Germany; and
| | - Volkmar Thom
- Sartorius Stedim Biotech GmbH, Göttingen, Germany
| | - Milan Polakovic
- Department of Chemical and Biochemical Engineering, Institute of Chemical and Environmental Engineering, Faculty of Chemical and Food Technology, Slovak University of Technology, Bratislava, Slovakia
| |
Collapse
|
178
|
Menzel R, Pahl I, Loewe T, Hauk A. Comparative Extractables Study of Autoclavable Polyethersulfone Filter Cartridges for Sterile Filtration. PDA J Pharm Sci Technol 2018; 72:298-316. [PMID: 29343620 DOI: 10.5731/pdajpst.2017.008367] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Sterile filters are ubiquitous in biopharmaceutical manufacturing processes. Because such filters are in direct contact with the process fluid, profiling of the extractables is of utmost importance. The work presented here reveals the extractables profile from filter cartridges for sterilizing-grade filtration, which were obtained from six different vendors. All filters contain a 0.2 μm polyethersulfone membrane for sterile filtration combined with a polyethersulfone pre-filter with retention rates spanning from 0.4 to 0.6 μm. These filter cartridges are designed for use in stainless steel housings which allow for in-line steam sterilization. A combination of different analytical techniques such as (headspace) gas chromatography-mass spectrometry, ultra-performance liquid chromatography-high-resolution mass spectrometry (electrospray ionization), inductively coupled plasma mass spectrometry, total organic carbon, non-volatile residue, conductivity, and pH value were applied to develop a comprehensive extractables profile on a qualitative and semi-quantitative basis. Pure ethanol and purified water were used as extraction media. The extractables profile consisted of various polyolefin-related extractables, additives such as antioxidants and degradation products thereof, hydrocarbons, and processing aids in addition to membrane-related extractables.LAY ABSTRACT: Filter cartridges or other filter products for sterile filtration are currently most commonly made of polymeric materials such as polypropylene, and a filter membrane material such as polyethersulfone. These materials will usually release chemical substances upon extraction in the laboratory (extractables), or upon application in biopharmaceutical processing (leachables). Potential extractables and leachables are additives used to tailor the physicochemical properties and to protect the polymeric materials, or degradants of these substances, or they arise from substances used during the manufacturing of the filter cartridges. Multiple analytical techniques were applied here to investigate the concentration and chemical nature of extractables obtained upon application of two distinct extraction solvents. Typical extractables found were antioxidants or releasing agents in addition to compounds originating from the polyethersulfone membrane.
Collapse
|
179
|
Xie R, Wu M, Qu G, Ning P, Cai Y, Lv P. Treatment of coking wastewater by a novel electric assisted micro-electrolysis filter. J Environ Sci (China) 2018; 66:165-172. [PMID: 29628083 DOI: 10.1016/j.jes.2017.05.034] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2016] [Revised: 05/22/2017] [Accepted: 05/23/2017] [Indexed: 06/08/2023]
Abstract
A newly designed electric assisted micro-electrolysis filter (E-ME) was developed to investigate its degradation efficiency for coking wastewater and correlated characteristics. The performance of the E-ME system was compared with separate electrolysis (SE) and micro-electrolysis (ME) systems. The results showed a prominent synergistic effect on COD removal in E-ME systems. Gas chromatography/mass spectrometry (GC-MS) analysis confirmed that the applied electric field enhanced the degradation of phenolic compounds. Meanwhile, more biodegradable oxygen-bearing compounds were detected. SEM images of granular activated carbon (GAC) showed that inactivation and blocking were inhibited during the E-ME process. The effects of applied voltage and initial pH in E-ME systems were also studied. The best voltage value was 1V, but synergistic effects existed even with lower applied voltage. E-ME systems exhibited some pH buffering capacity and attained the best efficiency in neutral media, which means that there is no need to adjust pH prior to or during the treatment process. Therefore, E-ME systems were confirmed as a promising technology for treatment of coking wastewater and other refractory wastewater.
Collapse
Affiliation(s)
- Ruosong Xie
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming 650500, China.
| | - Miaomiao Wu
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming 650500, China
| | - Guangfei Qu
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming 650500, China.
| | - Ping Ning
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming 650500, China
| | - Yingying Cai
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming 650500, China
| | - Pei Lv
- Faculty of Environmental Science and Engineering, Kunming University of Science & Technology, Kunming 650500, China
| |
Collapse
|
180
|
Newcomer DA, LaPuma P, Brandys R, Northcross A. Capture efficiency of portable high-efficiency air filtration devices used during building construction activities. J Occup Environ Hyg 2018; 15:285-292. [PMID: 29286879 DOI: 10.1080/15459624.2017.1422869] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The portable high-efficiency air filtration (PHEAF) device is used to control particulate matter (PM) generated from construction-type activities occurring within the built environment. Examples of activities where PHEAF devices are mobilized include building renovation, asbestos abatement, remediation of microbial contamination, and lead-based paint projects. Designed for use on short-term, temporary projects the PHEAF device captures airborne PM using a high-efficiency particulate air (HEPA) filter. This study sought to evaluate the capture efficiency of the PHEAF device in a field setting. An aerosol generator and photometer were used to measure particle penetration through 85 PHEAF devices. Average overall capture efficiency ranged from 41.78% to ≥99.97% with more than 88% of the tests failing to achieve 99.97% capture efficiency. Approximately 73% of the PHEAF device sample population failed to demonstrate HEPA performance criteria during any test round. A higher occurrence of PM concentrations measured around the perimeter of the filter suggested the presence of bypass leakage. While PHEAF devices were effective in capturing a significant quantity of aerosol test agent, these findings suggest that routine testing of the PHEAF device should be conducted to validate performance.
Collapse
Affiliation(s)
| | - Peter LaPuma
- b Milken Institute School of Public Health , George Washington University , Washington, DC
| | - Robert Brandys
- c Occupational & Environmental Health Consulting Services, Inc
| | - Amanda Northcross
- b Milken Institute School of Public Health , George Washington University , Washington, DC
| |
Collapse
|
181
|
Kim KJ, Jang A. Presence of Fe-Al binary oxide adsorbent cake layer in ceramic membrane filtration and their impact for removal of HA and BSA. Chemosphere 2018; 196:440-452. [PMID: 29329081 DOI: 10.1016/j.chemosphere.2018.01.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2017] [Revised: 01/03/2018] [Accepted: 01/04/2018] [Indexed: 06/07/2023]
Abstract
To enhance the removal of natural organic matter (NOM) in ceramic (Ce) membrane filtration, an iron-aluminum binary oxide (FAO) was applied to the ceramic membrane surface as the adsorbent cake layer, and it was compared with heated aluminum oxide (HAO) for the evaluation of the control of NOM. Both the HAO and FAO adsorbent cake layers efficiently removed the NOM regardless of NOM's hydrophobic/hydrophilic characteristics, and the dissolved organic carbon (DOC) removal in NOM for FAO was 1-1.12 times greater than that for HAO, which means FAO was more efficient in the removal of DOC in NOM. FAO (0.03 μm), which is smaller in size than HAO (0.4 μm), had greater flux reduction than HAO. The flux reduction increased as the filtration proceeded because most of the organic foulants (colloid/particles and soluble NOM) were captured by the adsorbent cake layer, which caused fouling between the membrane surface and the adsorbent cake layer. However, no chemically irreversible fouling was observed on the Ce membrane at the end of the FAO adsorbent cake layer filtration. This means that a stable adsorbent cake layer by FAO formed on the Ce membrane, and that the reduced pure water flux of the Ce membrane, resulting from the NOM fouling, can easily be recovered through physicochemical cleaning.
Collapse
Affiliation(s)
- Kyung-Jo Kim
- Graduate School of Water Resources, Sungkyunkwan University, Jangan-gu, Suwon, Gyeonggi-do, 16419, Republic of Korea
| | - Am Jang
- Graduate School of Water Resources, Sungkyunkwan University, Jangan-gu, Suwon, Gyeonggi-do, 16419, Republic of Korea.
| |
Collapse
|
182
|
Chuang FJ, Chou MS, Chang HY. Biotrickling filtration of airborne styrene: A comparison of filtration media. J Air Waste Manag Assoc 2018; 68:369-376. [PMID: 29309259 DOI: 10.1080/10962247.2017.1416002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Accepted: 10/27/2017] [Indexed: 06/07/2023]
Abstract
UNLABELLED This study compares the performances of fern and plastic chips as packing media for the biofiltration of a styrene-laden waste gas stream emitted in a plant for the manufacture of plastic door plates. Fern chips (with a specific surface area of 1090 m2 m-3) and plastic chips (with a specific surface area of 610 m2 m-3) were packed into a pilot-scale biotrickling filter with a total medium volume of 50 L for the performance test. Field waste gas with styrene concentrations in the range of 161-2390 mg Am-3 at 28-30 °C) was introduced to the bed and a fixed empty-bed retention time (EBRT) of 21 sec, a volumetric gas flow rate of 8.57 m3 hr-1, and superficial gas velocity of 53.6 m hr-1 were maintained throughout the experimental period. Nutrients containing metal salts, nitrogen, phosphorus, and milk were supplemented to the filters for maintaining the microbial activities. Results reveal that the biotrickling filter developed in this study had the highest styrene monomer (SM) elimination capacities (170 g m-3 hr-1 for fern-chip packing and 300 g m-3 hr-1 for plastic-chip packing) among those cited in the literature. The plastic medium is a favorable substitute for endangered fern chips. The thermal-setting nature of plastic chips limits their recycle and reuse as raw materials, and the study provides an opportunity for the utilization of the materials. IMPLICATIONS Biotreatment of contaminants in air streams offers an inexpensive and efficient alternative to conventional technologies. Biofiltration has a great potential for the degradation of gas-borne styrene and total hydrocarbon (THC) removal efficiency of around 80%. The objective of this research was to compare the performances of fern chips and a kind of plastic chips as packing media for biofiltration of the styrene-laden waste gas stream emitted from cutting operations of stripes of premixed unsaturated polyester (UP) and styrene paste before hot-pressing operations for making plastic door plates. From a practical point of view, the plastic medium can be a good substitute medium for fern chips, which has been declared as a protected plant. This study provides an experimentally verified model for the design and operation of such biotreatment systems.
Collapse
Affiliation(s)
- Fu-Jen Chuang
- a Institute of Environmental Engineering , National Sun Yat-Sen University , Kaohsiung , Taiwan , Republic of China
| | - Ming-Shean Chou
- a Institute of Environmental Engineering , National Sun Yat-Sen University , Kaohsiung , Taiwan , Republic of China
| | - Hsiao-Yu Chang
- a Institute of Environmental Engineering , National Sun Yat-Sen University , Kaohsiung , Taiwan , Republic of China
| |
Collapse
|
183
|
Insel G, Karagunduz A, Aksel M, Cokgor E, Kor-Bicakci G, Ozyildiz G, Toroz I, Keskinler B. Membrane integrated process for advanced treatment of high strength Opium Alkaloid wastewaters. Water Sci Technol 2018; 77:1899-1908. [PMID: 29676747 DOI: 10.2166/wst.2018.065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In this study, an integrated aerobic membrane bioreactor (MBR)-nanofiltration (NF) system has been applied for advanced treatment of Opium processing wastewaters to comply with strict discharge limits. Aerobic MBR treatment was successfully applied to high strength industrial wastewater. In aerobic MBR treatment, a non-fouling unique slot aeration system was designed using computational fluid dynamics techniques. The MBR was used to separate treated effluent from dispersed and non-settleable biomass. Respirometric modeling using MBR sludge indicated that the biomass exhibited similar kinetic parameters to that of municipal activated sludge systems. Aerobic MBR/NF treatment reduced chemical oxygen demand (COD) from 32,000 down to 2,500 and 130 mg/L, respectively. The MBR system provided complete removal of total inorganic nitrogen; however, nearly 50 mgN/L organic nitrogen remained in the permeate. Post NF treatment after MBR permeate reduced nitrogen below 20 mgN/L, providing nearly total color removal. In addition, a 90% removal in the conductivity parameter was reached with an integrated MBR/NF system. Finally, post NF application to MBR permeate was found not to be practical at higher pH due to low flux (3-4 L/m2/hour) with low recovery rates (30-40%). As the permeate pH lowered to 5.5, 75% of NF recovery was achieved at a flux of 15 L/m2/hour.
Collapse
Affiliation(s)
- Güçlü Insel
- Environmental Engineering Department, Istanbul Technical University, Maslak, Istanbul, Turkey E-mail:
| | - Ahmet Karagunduz
- Environmental Engineering Department, Gebze Technical University, Gebze, Izmit, Turkey
| | - Murat Aksel
- Civil Engineering Department, Kültür University, Yenibosna, Istanbul, Turkey
| | - Emine Cokgor
- Environmental Engineering Department, Istanbul Technical University, Maslak, Istanbul, Turkey E-mail:
| | - Gokce Kor-Bicakci
- Environmental Engineering Department, Istanbul Technical University, Maslak, Istanbul, Turkey E-mail:
| | - Goksin Ozyildiz
- Environmental Engineering Department, Istanbul Technical University, Maslak, Istanbul, Turkey E-mail:
| | - Ismail Toroz
- Environmental Engineering Department, Istanbul Technical University, Maslak, Istanbul, Turkey E-mail:
| | - Bulent Keskinler
- Environmental Engineering Department, Gebze Technical University, Gebze, Izmit, Turkey
| |
Collapse
|
184
|
Christensen GA, Moon J, Veach AM, Mosher JJ, Wymore AM, van Nostrand JD, Zhou J, Hazen TC, Arkin AP, Elias DA. Use of in-field bioreactors demonstrate groundwater filtration influences planktonic bacterial community assembly, but not biofilm composition. PLoS One 2018; 13:e0194663. [PMID: 29558522 PMCID: PMC5860781 DOI: 10.1371/journal.pone.0194663] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Accepted: 03/07/2018] [Indexed: 02/01/2023] Open
Abstract
Using in-field bioreactors, we investigated the influence of exogenous microorganisms in groundwater planktonic and biofilm microbial communities as part of the Integrated Field Research Challenge (IFRC). After an acclimation period with source groundwater, bioreactors received either filtered (0.22 μM filter) or unfiltered well groundwater in triplicate and communities were tracked routinely for 23 days after filtration was initiated. To address geochemical influences, the planktonic phase was assayed periodically for protein, organic acids, physico-/geochemical measurements and bacterial community (via 16S rRNA gene sequencing), while biofilms (i.e. microbial growth on sediment coupons) were targeted for bacterial community composition at the completion of the experiment (23 d). Based on Bray-Curtis distance, planktonic bacterial community composition varied temporally and between treatments (filtered, unfiltered bioreactors). Notably, filtration led to an increase in the dominant genus, Zoogloea relative abundance over time within the planktonic community, while remaining relatively constant when unfiltered. At day 23, biofilm communities were more taxonomically and phylogenetically diverse and substantially different from planktonic bacterial communities; however, the biofilm bacterial communities were similar regardless of filtration. These results suggest that although planktonic communities were sensitive to groundwater filtration, bacterial biofilm communities were stable and resistant to filtration. Bioreactors are useful tools in addressing questions pertaining to microbial community assembly and succession. These data provide a first step in understanding how an extrinsic factor, such as a groundwater inoculation and flux of microbial colonizers, impact how microbial communities assemble in environmental systems.
Collapse
Affiliation(s)
- Geoff A. Christensen
- Biosciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, United States of America
| | - JiWon Moon
- Biosciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, United States of America
| | - Allison M. Veach
- Biosciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, United States of America
| | - Jennifer J. Mosher
- Marshall University, Biological Sciences, Huntington, West Virginia, United States of America
| | - Ann M. Wymore
- Biosciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, United States of America
| | | | - Jizhong Zhou
- University of Oklahoma, Norman, Oklahoma, United States of America
| | - Terry C. Hazen
- Biosciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, United States of America
- University of Tennessee, Knoxville, Tennessee, United States of America
| | - Adam P. Arkin
- Lawrence Berkeley National Laboratory, Berkeley, California, United States of America
- University of California at Berkeley, Berkeley, California, United States of America
| | - Dwayne A. Elias
- Biosciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, United States of America
- * E-mail:
| |
Collapse
|
185
|
Trellu C, Coetsier C, Rouch JC, Esmilaire R, Rivallin M, Cretin M, Causserand C. Mineralization of organic pollutants by anodic oxidation using reactive electrochemical membrane synthesized from carbothermal reduction of TiO 2. Water Res 2018; 131:310-319. [PMID: 29306202 DOI: 10.1016/j.watres.2017.12.070] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Revised: 12/22/2017] [Accepted: 12/24/2017] [Indexed: 06/07/2023]
Abstract
Reactive Electrochemical Membrane (REM) prepared from carbothermal reduction of TiO2 is used for the mineralization of biorefractory pollutants during filtration operation. The mixture of Ti4O7 and Ti5O9 Magnéli phases ensures the high reactivity of the membrane for organic compound oxidation through •OH mediated oxidation and direct electron transfer. In cross-flow filtration mode, convection-enhanced mass transport of pollutants can be achieved from the high membrane permeability (3300 LMH bar-1). Mineralization efficiency of oxalic acid, paracetamol and phenol was assessed as regards to current density, transmembrane pressure and feed concentration. Unprecedented high removal rates of total organic carbon and mineralization current efficiency were achieved after a single passage through the REM, e.g. 47 g m-2 h-1 - 72% and 6.7 g m-2 h-1 - 47% for oxalic acid and paracetamol, respectively, at 15 mA cm-2. However, two mechanisms have to be considered for optimization of the process. When the TOC flux is too high with respect to the current density, aromatic compounds polymerize in the REM layer where only direct electron transfer occurs. This phenomenon decreases the oxidation efficiency and/or increases REM fouling. Besides, O2 bubbles sweeping at high permeate flux promotes O2 gas generation, with adverse effect on oxidation efficiency.
Collapse
Affiliation(s)
- Clément Trellu
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France.
| | - Clémence Coetsier
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France
| | - Jean-Christophe Rouch
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France
| | - Roseline Esmilaire
- Institut Européen des Membranes, UMR 5635 (CNRS-ENSCM-UM), Montpellier, France
| | - Matthieu Rivallin
- Institut Européen des Membranes, UMR 5635 (CNRS-ENSCM-UM), Montpellier, France
| | - Marc Cretin
- Institut Européen des Membranes, UMR 5635 (CNRS-ENSCM-UM), Montpellier, France
| | - Christel Causserand
- Laboratoire de Génie Chimique, Université de Toulouse, CNRS, INPT, UPS, Toulouse, France
| |
Collapse
|
186
|
Thiruraman JP, Fujisawa K, Danda G, Das PM, Zhang T, Bolotsky A, Perea-López N, Nicolaï A, Senet P, Terrones M, Drndić M. Angstrom-Size Defect Creation and Ionic Transport through Pores in Single-Layer MoS 2. Nano Lett 2018; 18:1651-1659. [PMID: 29464959 DOI: 10.1021/acs.nanolett.7b04526] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Atomic-defect engineering in thin membranes provides opportunities for ionic and molecular filtration and analysis. While molecular-dynamics (MD) calculations have been used to model conductance through atomic vacancies, corresponding experiments are lacking. We create sub-nanometer vacancies in suspended single-layer molybdenum disulfide (MoS2) via Ga+ ion irradiation, producing membranes containing ∼300 to 1200 pores with average and maximum diameters of ∼0.5 and ∼1 nm, respectively. Vacancies exhibit missing Mo and S atoms, as shown by aberration-corrected scanning transmission electron microscopy (AC-STEM). The longitudinal acoustic band and defect-related photoluminescence were observed in Raman and photoluminescence spectroscopy, respectively. As the irradiation dose is increased, the median vacancy area remains roughly constant, while the number of vacancies (pores) increases. Ionic current versus voltage is nonlinear and conductance is comparable to that of ∼1 nm diameter single MoS2 pores, proving that the smaller pores in the distribution display negligible conductance. Consistently, MD simulations show that pores with diameters <0.6 nm are almost impermeable to ionic flow. Atomic pore structure and geometry, studied by AC-STEM, are critical in the sub-nanometer regime in which the pores are not circular and the diameter is not well-defined. This study lays the foundation for future experiments to probe transport in large distributions of angstrom-size pores.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Adrien Nicolaï
- Laboratoire Interdisciplinaire Carnot de Bourgogne UMR 6303 CNRS-Université de Bourgogne Franche Comté , 9 Avenue Alain Savary , BP 47870, F-21078 Dijon Cedex , France
| | - Patrick Senet
- Laboratoire Interdisciplinaire Carnot de Bourgogne UMR 6303 CNRS-Université de Bourgogne Franche Comté , 9 Avenue Alain Savary , BP 47870, F-21078 Dijon Cedex , France
| | | | | |
Collapse
|
187
|
Parker JK, Lignou S, Shankland K, Kurwie P, Griffiths HD, Baines DA. Development of a Zeolite Filter for Removing Polycyclic Aromatic Hydrocarbons (PAHs) from Smoke and Smoked Ingredients while Retaining the Smoky Flavor. J Agric Food Chem 2018; 66:2449-2458. [PMID: 28215083 DOI: 10.1021/acs.jafc.6b05399] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The popularity of smoked foodstuffs such as sauces, marinades, and rubs is on the rise. However, during the traditional smoking process, in addition to the desirable smoky aroma compounds, harmful polycyclic aromatic hydrocarbons (PAHs) are also generated. In this work, a selective filter was developed that reduces PAH concentrations in a smoke by up to 90% while maintaining a desirable smoky flavor. Preliminary studies using a cocktail of 12 PAHs stirred with a zeolite showed the potential for this zeolite to selectively remove PAHs from a simple solution. However, pretreatment of the smoke prior to application removed the PAHs more efficiently and is more widely applicable to a range of food ingredients. Although volatile analysis showed that there was a concomitant reduction in the concentration of the smoky compounds such as 2-methoxyphenol (guaiacol), 2-methylphenol ( o-cresol), and the isoeugenols, sensory profiling showed that the difference in perception of flavor was minimal.
Collapse
Affiliation(s)
- Jane K Parker
- School of Chemistry, Food and Pharmacy , University of Reading , Whiteknights, Reading RG6 6AP , United Kingdom
| | - Stella Lignou
- School of Chemistry, Food and Pharmacy , University of Reading , Whiteknights, Reading RG6 6AP , United Kingdom
| | - Kenneth Shankland
- School of Chemistry, Food and Pharmacy , University of Reading , Whiteknights, Reading RG6 6AP , United Kingdom
| | - Phillipa Kurwie
- School of Chemistry, Food and Pharmacy , University of Reading , Whiteknights, Reading RG6 6AP , United Kingdom
| | - Huw D Griffiths
- Unit B1, Ford Airfield Industrial Estate , Besmoke Ltd. , Arundel BN18 0HY , United Kingdom
| | - David A Baines
- Baines Food Consultancy Ltd. , 22 Elisabeth Close , Thornbury , Bristol BS35 2YN , United Kingdom
| |
Collapse
|
188
|
Chan N, Young-Rojanschi C, Li S. Effect of water-to-cement ratio and curing method on the strength, shrinkage and slump of the biosand filter concrete body. Water Sci Technol 2018; 77:1744-1750. [PMID: 29595177 DOI: 10.2166/wst.2018.063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The biosand filter is a household-level water treatment technology used globally in low-resource settings. As of December 2016, over 900,000 biosand filters had been implemented in 60 countries around the world. Local, decentralized production is one of the main advantages of this technology, but it also creates challenges, especially in regards to quality control. Using the current recommended proportions for the biosand filter concrete mix, slump was measured at water-to-cement ratios of 0.51, 0.64 and 0.76, with two replicates for each level. Twenty-eight-day strength was tested on four replicate cylinders, each at water-to-cement ratios of 0.51, 0.59, 0.67 and 0.76. Wet curing and dry curing were compared for 28-day strength and for their effect on shrinkage. Maximum strength occurred at water-to-cement ratios of 0.51-0.59, equivalent to 8-9.3 L water for a full-scale filter assuming saturated media, corresponding to a slump class of S1 (10-40 mm). Wet curing significantly improved strength of the concrete mix and reduced shrinkage. Quality control measures such as the slump test can significantly improve the quality within decentralized production of biosand filters, despite localized differences in production conditions.
Collapse
Affiliation(s)
- Nicole Chan
- University of Calgary, 2500 University Dr NW, Calgary, AB T2N 1N4, Canada
| | - Candice Young-Rojanschi
- Centre for Affordable Water and Sanitation Technology (CAWST), Upper 424 Aviation Road NE, Calgary, AB T2E 8H6, Canada
| | - Simon Li
- Department of Mechanical Engineering, University of Calgary, 2500 University Dr NW, Calgary, AB T2N 1N4, Canada E-mail:
| |
Collapse
|
189
|
Newton SR, McMahen RL, Sobus JR, Mansouri K, Williams AJ, McEachran AD, Strynar MJ. Suspect screening and non-targeted analysis of drinking water using point-of-use filters. Environ Pollut 2018; 234:297-306. [PMID: 29182974 PMCID: PMC6145080 DOI: 10.1016/j.envpol.2017.11.033] [Citation(s) in RCA: 80] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 11/07/2017] [Accepted: 11/08/2017] [Indexed: 05/18/2023]
Abstract
Monitored contaminants in drinking water represent a small portion of the total compounds present, many of which may be relevant to human health. To understand the totality of human exposure to compounds in drinking water, broader monitoring methods are imperative. In an effort to more fully characterize the drinking water exposome, point-of-use water filtration devices (Brita® filters) were employed to collect time-integrated drinking water samples in a pilot study of nine North Carolina homes. A suspect screening analysis was performed by matching high resolution mass spectra of unknown features to molecular formulas from EPA's DSSTox database. Candidate compounds with those formulas were retrieved from the EPA's CompTox Chemistry Dashboard, a recently developed data hub for approximately 720,000 compounds. To prioritize compounds into those most relevant for human health, toxicity data from the US federal collaborative Tox21 program and the EPA ToxCast program, as well as exposure estimates from EPA's ExpoCast program, were used in conjunction with sample detection frequency and abundance to calculate a "ToxPi" score for each candidate compound. From ∼15,000 molecular features in the raw data, 91 candidate compounds were ultimately grouped into the highest priority class for follow up study. Fifteen of these compounds were confirmed using analytical standards including the highest priority compound, 1,2-Benzisothiazolin-3-one, which appeared in 7 out of 9 samples. The majority of the other high priority compounds are not targets of routine monitoring, highlighting major gaps in our understanding of drinking water exposures. General product-use categories from EPA's CPCat database revealed that several of the high priority chemicals are used in industrial processes, indicating the drinking water in central North Carolina may be impacted by local industries.
Collapse
Affiliation(s)
- Seth R Newton
- United States Environmental Protection Agency, National Exposure Research Laboratory, Research Triangle Park, NC 27709, United States.
| | - Rebecca L McMahen
- United States Environmental Protection Agency, National Exposure Research Laboratory, Research Triangle Park, NC 27709, United States; Oak Ridge Institute for Science and Education Research Participant, 109 T.W. Alexander Drive, Research Triangle Park, NC 27709, United States
| | - Jon R Sobus
- United States Environmental Protection Agency, National Exposure Research Laboratory, Research Triangle Park, NC 27709, United States
| | - Kamel Mansouri
- Oak Ridge Institute for Science and Education Research Participant, 109 T.W. Alexander Drive, Research Triangle Park, NC 27709, United States; United States Environmental Protection Agency, National Center for Computational Toxicology, Research Triangle Park, NC 27709, United States
| | - Antony J Williams
- United States Environmental Protection Agency, National Center for Computational Toxicology, Research Triangle Park, NC 27709, United States
| | - Andrew D McEachran
- Oak Ridge Institute for Science and Education Research Participant, 109 T.W. Alexander Drive, Research Triangle Park, NC 27709, United States; United States Environmental Protection Agency, National Center for Computational Toxicology, Research Triangle Park, NC 27709, United States
| | - Mark J Strynar
- United States Environmental Protection Agency, National Exposure Research Laboratory, Research Triangle Park, NC 27709, United States
| |
Collapse
|
190
|
Xiao R, Mo J, Zhang Y, Gao D. An in-situ thermally regenerated air purifier for indoor formaldehyde removal. Indoor Air 2018; 28:266-275. [PMID: 29168902 DOI: 10.1111/ina.12441] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2017] [Accepted: 11/14/2017] [Indexed: 06/07/2023]
Abstract
Formaldehyde is a common indoor pollutant that is an irritant and has been classified as carcinogen to humans. Adsorption technology is safe and stable and removes formaldehyde efficiently, but its short life span and low adsorption capacity limit its indoor application. To overcome these limitations, we propose an in-situ thermally regenerated air purifier (TRAP) which self-regenerates as needed. This purifier has four working modes: cleaning mode, regeneration mode, exhaust mode, and outdoor air in-take mode, all of which are operated by valve switching. We developed a real-scale TRAP prototype with activated carbon as adsorbent. The experimental testing showed that the regeneration ratios for formaldehyde of TRAP were greater than 90% during 5 cycles of adsorption-regeneration and that through the 5 cycles, there was no damage to the adsorption material as confirmed by scanning electron microscope (SEM) and Brunauer-Emmett-Teller (BET) tests. The total energy consumption by the prototype for purifying 1000 m3 indoor air was 0.26 kWh. This in-situ thermal-regeneration method can recover the purifier's adsorption ability through at least five cycles.
Collapse
Affiliation(s)
- R Xiao
- Department of Building Science, Tsinghua University, Beijing, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - J Mo
- Department of Building Science, Tsinghua University, Beijing, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - Y Zhang
- Department of Building Science, Tsinghua University, Beijing, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - D Gao
- Department of Building Science, Tsinghua University, Beijing, China
| |
Collapse
|
191
|
Wang Y, Wang X, Li M, Dong J, Sun C, Chen G. Removal of Pharmaceutical and Personal Care Products (PPCPs) from Municipal Waste Water with Integrated Membrane Systems, MBR-RO/NF. Int J Environ Res Public Health 2018; 15:ijerph15020269. [PMID: 29401723 PMCID: PMC5858338 DOI: 10.3390/ijerph15020269] [Citation(s) in RCA: 70] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Revised: 01/15/2018] [Accepted: 01/22/2018] [Indexed: 11/16/2022]
Abstract
This study focuses on the application of combining membrane bioreactor (MBR) treatment with reverse osmosis (RO) or nanofiltration (NF) membrane treatment for removal of pharmaceuticals and personal care products (PPCPs) in municipal wastewater. Twenty-seven PPCPs were measured in real influent with lowest average concentration being trimethoprim (7.12 ng/L) and the highest being caffeine (18.4 ng/L). The results suggest that the MBR system effectively removes the PPCPs with an efficiency of between 41.08% and 95.41%, and that the integrated membrane systems, MBR-RO/NF, can achieve even higher removal rates of above 95% for most of them. The results also suggest that, due to the differences in removal mechanisms of NF/RO membrane, differences of removal rates exist. In this study, the combination of MBR-NF resulted in the removal of 13 compounds to below detection limits and MBR-RO achieved even better results with removal of 20 compounds to below detection limits.
Collapse
Affiliation(s)
- Yonggang Wang
- School of Environmental Science and Engineering, Tianjin University, No. 92, Weijin Road, Nankai District, Tianjin 300072, China.
- Beijing Municipal Research Academy of Environmental Protection, No. 59, Beiyingfang Middle Street, Xicheng District, Beijing 100037, China.
- National Engineering Research Center for Urban Environmental Pollution Control, No. 59, Beiyingfang Middle Street, Xicheng District, Beijing 100037, China.
| | - Xu Wang
- Beijing Municipal Research Academy of Environmental Protection, No. 59, Beiyingfang Middle Street, Xicheng District, Beijing 100037, China.
- National Engineering Research Center for Urban Environmental Pollution Control, No. 59, Beiyingfang Middle Street, Xicheng District, Beijing 100037, China.
| | - Mingwei Li
- Beijing Municipal Research Academy of Environmental Protection, No. 59, Beiyingfang Middle Street, Xicheng District, Beijing 100037, China.
- National Engineering Research Center for Urban Environmental Pollution Control, No. 59, Beiyingfang Middle Street, Xicheng District, Beijing 100037, China.
| | - Jing Dong
- Beijing Municipal Research Academy of Environmental Protection, No. 59, Beiyingfang Middle Street, Xicheng District, Beijing 100037, China.
- National Engineering Research Center for Urban Environmental Pollution Control, No. 59, Beiyingfang Middle Street, Xicheng District, Beijing 100037, China.
| | - Changhong Sun
- Beijing Municipal Research Academy of Environmental Protection, No. 59, Beiyingfang Middle Street, Xicheng District, Beijing 100037, China.
- National Engineering Research Center for Urban Environmental Pollution Control, No. 59, Beiyingfang Middle Street, Xicheng District, Beijing 100037, China.
| | - Guanyi Chen
- School of Environmental Science and Engineering, Tianjin University, No. 92, Weijin Road, Nankai District, Tianjin 300072, China.
| |
Collapse
|
192
|
Di Iorio BR, Di Micco L, Russo L, Nardone L, De Simone E, Sirico ML, Di Natale G, Russo D. A strategy to reduce inflammation and anemia treatment's related costs in dialysis patients. G Ital Nefrol 2018; 35:2018-vol1-10. [PMID: 29390245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This is a post-hoc analysis evaluating erythropoiesis stimulating agents' (ESA) related costs while using an additional ultrafilter (Estorclean PLUS) to produce ultrapure dialysis water located within the fluid pathway after the treatment with reverse osmosis and before the dialysis machine. Twenty-nine patients (19 treated with epoetin alfa and 10 with darboepoetin alfa) were included in the analysis. We showed to gain savings of 210 € per patient (35 € per patient each month) with epoetin alfa during the experimental period of 6 months, compared to the control period and of 545 € per patient (90 € per patient each month) with darboepoetin alfa. Estorclean PLUS had a cost of 600 € (25 € per month per each patient) and was used for 6 months. Intravenous iron therapy with sodium ferrigluconate had a cost of 0,545 €/62,5 mg. In conclusion, during the experimental period with the use of Estorclean, we obtained global savings of 11 € per patient per month with epoetin alfa and 30 € per patient per month with darboepoetin alfa to treat anemia in dialysis patients.
Collapse
Affiliation(s)
- Biagio R Di Iorio
- Department of Nephrology, A. Landolfi Hospital, Solofra, Avellino, Italy
| | | | - Luigi Russo
- Chair of Nephrology, University of Naples Federico II, Naples, Italy
| | - Luca Nardone
- Department of Nephrology, A. Landolfi Hospital, Solofra, Avellino, Italy
| | | | - M L Sirico
- Department of Nephrology, A. Landolfi Hospital, Solofra, Avellino, Italy
| | | | - Domenico Russo
- Chair of Nephrology, University of Naples Federico II, Naples, Italy
| |
Collapse
|
193
|
Vignola M, Werner D, Wade MJ, Meynet P, Davenport RJ. Medium shapes the microbial community of water filters with implications for effluent quality. Water Res 2018; 129:499-508. [PMID: 29195186 DOI: 10.1016/j.watres.2017.09.042] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2017] [Revised: 09/06/2017] [Accepted: 09/22/2017] [Indexed: 05/15/2023]
Abstract
Little is known about the forces that determine the assembly of diverse bacterial communities inhabiting drinking water treatment filters and how this affects drinking water quality. Two contrasting ecological theories can help to understand how natural microbial communities assemble; niche theory and neutral theory, where environmental deterministic factors or stochastic factors predominate respectively. This study investigates the development of the microbial community on two common contrasting filter materials (quartz sand and granular activated carbon-GAC), to elucidate the main factors governing their assembly, through the evaluation of environmental (i.e. filter medium type) and stochastic forces (random deaths, births and immigration). Laboratory-scale filter columns were used to mimic a rapid gravity filter; the microbiome of the filter materials, and of the filter influent and effluent, was characterised using next generation 16S rRNA gene amplicon sequencing and flow-cytometry. Chemical parameters (i.e. dissolved organic carbon, trihalomethanes formation) were also monitored to assess the final effluent quality. The filter communities seemed to be strongly assembled by selection rather than neutral processes, with only 28% of those OTUs shared with the source water detected on the filter medium following predictions using a neutral community model. GAC hosted a phylogenetically more diverse community than sand. The two filter media communities seeded the effluent water, triggering differences in both water quality and community composition of the effluents. Overall, GAC proved to be better than sand in controlling microbial growth, by promoting higher bacterial decay rates and hosting less bacterial cells, and showed better performance for putative pathogen control by leaking less Legionella cells into the effluent water.
Collapse
Affiliation(s)
- Marta Vignola
- School of Engineering, Newcastle University, Newcastle Upon Tyne, NE1 7RU, United Kingdom; College of Science and Engineering, Division of Infrastructure and Environment, School of Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom.
| | - David Werner
- School of Engineering, Newcastle University, Newcastle Upon Tyne, NE1 7RU, United Kingdom
| | - Matthew J Wade
- School of Engineering, Newcastle University, Newcastle Upon Tyne, NE1 7RU, United Kingdom
| | - Paola Meynet
- School of Engineering, Newcastle University, Newcastle Upon Tyne, NE1 7RU, United Kingdom; Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstr. 133, Dübendorf, CH-8600, Switzerland
| | - Russell J Davenport
- School of Engineering, Newcastle University, Newcastle Upon Tyne, NE1 7RU, United Kingdom
| |
Collapse
|
194
|
Song L, Zhu B, Jegatheesan V, Gray S, Duke M, Muthukumaran S. Treatment of secondary effluent by sequential combination of photocatalytic oxidation with ceramic membrane filtration. Environ Sci Pollut Res Int 2018; 25:5191-5202. [PMID: 28462432 DOI: 10.1007/s11356-017-9070-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Accepted: 04/20/2017] [Indexed: 06/07/2023]
Abstract
The aim of the present work was to experimentally evaluate an alternative advanced wastewater treatment system, which combines the action of photocatalytic oxidation with ceramic membrane filtration. Experiments were carried out using laboratory scale TiO2/UV photocatalytic reactor and tubular ceramic microfiltration (CMF) system to treat the secondary effluent (SE). A 100-nm pore size CMF membrane was investigated in cross flow mode under constant transmembrane pressure of 20 kPa. The results show that specific flux decline of CMF membrane with and without TiO2/UV photocatalytic treatment was 30 and 50%, respectively, after 60 min of filtration. Data evaluation revealed that the adsorption of organic compounds onto the TiO2 particles was dependent on the pH of the suspension and was considerably higher at low pH. The liquid chromatography-organic carbon detector (LC-OCD) technique was used to characterise the dissolved organic matter (DOM) present in the SE and was monitored following photocatalysis and CMF. The results showed that there was no removal of biopolymers and slight removal of humics, building blocks and the other oxidation by-products after TiO2/UV photocatalytic treatment. This result suggested that the various ions present in the SE act as scavengers, which considerably decrease the efficiency of the photocatalytic oxidation reactions. On the other hand, the CMF was effective for removing 50% of biopolymers with no further removal of other organic components after photocatalytic treatment. Thus, the quantity of biopolymers in SE has an apparent correlation with the filterability of water samples in CMF.
Collapse
Affiliation(s)
- Lili Song
- College of Biological and Environmental Engineering, Zhejiang University of Technology, Hangzhou, 310032, People's Republic of China
- Institute for Sustainability and Innovation, Victoria University, PO Box 14428, Melbourne, VIC, 8001, Australia
| | - Bo Zhu
- Institute for Sustainability and Innovation, Victoria University, PO Box 14428, Melbourne, VIC, 8001, Australia
- College of Engineering and Science, Victoria University, PO Box 14428, Melbourne, VIC, 8001, Australia
| | | | - Stephen Gray
- Institute for Sustainability and Innovation, Victoria University, PO Box 14428, Melbourne, VIC, 8001, Australia
- College of Engineering and Science, Victoria University, PO Box 14428, Melbourne, VIC, 8001, Australia
| | - Mikel Duke
- Institute for Sustainability and Innovation, Victoria University, PO Box 14428, Melbourne, VIC, 8001, Australia
- College of Engineering and Science, Victoria University, PO Box 14428, Melbourne, VIC, 8001, Australia
| | - Shobha Muthukumaran
- Institute for Sustainability and Innovation, Victoria University, PO Box 14428, Melbourne, VIC, 8001, Australia.
- College of Engineering and Science, Victoria University, PO Box 14428, Melbourne, VIC, 8001, Australia.
| |
Collapse
|
195
|
Singh SP, Li Y, Zhang J, Tour JM, Arnusch CJ. Sulfur-Doped Laser-Induced Porous Graphene Derived from Polysulfone-Class Polymers and Membranes. ACS Nano 2018; 12:289-297. [PMID: 29241007 DOI: 10.1021/acsnano.7b06263] [Citation(s) in RCA: 99] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Graphene based materials have profoundly impacted research in nanotechnology, and this has significantly advanced biomedical, electronics, energy, and environmental applications. Laser-induced graphene (LIG) is made photothermally and has enabled a rapid route for graphene layers on polyimide surfaces. However, polysulfone (PSU), poly(ether sulfone) (PES), and polyphenylsulfone (PPSU) are highly used in numerous applications including medical, energy, and water treatment and they are critical components of polymer membranes. Here we show LIG fabrication on PSU, PES, and PPSU resulting in conformal sulfur-doped porous graphene embedded in polymer dense films or porous substrates using reagent- and solvent-free methods in a single step. We demonstrate the applicability as flexible electrodes with enhanced electrocatalytic hydrogen peroxide generation, as antifouling surfaces and as antimicrobial hybrid membrane-LIG porous filters. The properties and surface morphology of the conductive PSU-, PES-, and PPSU-LIG could be modulated using variable laser duty cycles. The LIG electrodes showed enhanced hydrogen peroxide generation compared to LIG made on polyimide, and showed exceptional biofilm resistance and potent antimicrobial killing effects when treated with Pseudomonas aeruginosa and mixed bacterial culture. The hybrid PES-LIG membrane-electrode ensured complete elimination of bacterial viability in the permeate (6 log reduction), in a flow-through filtration mode at a water flux of ∼500 L m-2 h-1 (2.5 V) and at ∼22 000 L m-2 h-1 (20 V). Due to the widespread use of PSU, PES, and PPSU in modern society, these functional PSU-, PES-, and PPSU-LIG surfaces have great potential to be incorporated into biomedical, electronic, energy and environmental devices and technologies.
Collapse
Affiliation(s)
- Swatantra P Singh
- Department of Desalination and Water Treatment, Zuckerberg Institute for Water Research, The Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev , Sede-Boqer Campus 84990, Israel
| | - Yilun Li
- Department of Chemistry, Department of Materials Science and NanoEngineering, Smalley-Curl Institute and NanoCarbon Center, Nanosystems Engineering Research Center for Nanotechnology-Enabled Water Treatment, Rice University , 6100 Main Street, Houston, Texas 77005, United States
| | - Jibo Zhang
- Department of Chemistry, Department of Materials Science and NanoEngineering, Smalley-Curl Institute and NanoCarbon Center, Nanosystems Engineering Research Center for Nanotechnology-Enabled Water Treatment, Rice University , 6100 Main Street, Houston, Texas 77005, United States
| | - James M Tour
- Department of Chemistry, Department of Materials Science and NanoEngineering, Smalley-Curl Institute and NanoCarbon Center, Nanosystems Engineering Research Center for Nanotechnology-Enabled Water Treatment, Rice University , 6100 Main Street, Houston, Texas 77005, United States
| | - Christopher J Arnusch
- Department of Desalination and Water Treatment, Zuckerberg Institute for Water Research, The Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev , Sede-Boqer Campus 84990, Israel
| |
Collapse
|
196
|
Yang H, Yang L, Yuan Y, Pan S, Yang J, Yan J, Zhang H, Sun Q, Hu X. A portable synthesis of water-soluble carbon dots for highly sensitive and selective detection of chlorogenic acid based on inner filter effect. Spectrochim Acta A Mol Biomol Spectrosc 2018; 189:139-146. [PMID: 28806699 DOI: 10.1016/j.saa.2017.07.065] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2017] [Revised: 07/26/2017] [Accepted: 07/30/2017] [Indexed: 05/13/2023]
Abstract
In this work, a simple and facile hydrothermal method for synthesis of water-soluble carbon dots (CDs) with malic acid and urea, and were then employed as a high-performance fluorescent probe for selective and sensitive determination of chlorogenic acid (CGA) based on inner filter effect. The as-synthesized CDs was systematically characterized by Transmission electron microscopy (TEM), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), Energy disperse spectroscopy (EDS), UV-vis absorption spectroscopy, spectrofluorophotometry, and the results indicated that the sizes of CDs were mainly distributed in the range of 1.0nm-3.0nm with an average diameter of 2.1nm. More significantly, the as-prepared CDs possessed remarkable selectivity and sensitivity towards CGA with the linear range of 0.15μmolL-1-60μmolL-1 and the detection limit for CGA was 45nmolL-1 (3σ/k). The practical applications of CDs for detection of CGA have already been successfully demonstrated in Honeysuckle. This sensitive, selective method has a great application prospect in the pharmaceutical and biological analysis field owing to its simplicity and rapidity for the detection of CGA.
Collapse
Affiliation(s)
- Huan Yang
- Key Laboratory of Luminescent and Real-Time analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Liu Yang
- Key Laboratory of Luminescent and Real-Time analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Yusheng Yuan
- Key Laboratory of Luminescent and Real-Time analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Shuang Pan
- Key Laboratory of Luminescent and Real-Time analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Jidong Yang
- College of Chemical and Environmental Engineering, Chongqing Three Gorges University, Wanzhou, Chongqing 404100, China
| | - Jingjing Yan
- Key Laboratory of Luminescent and Real-Time analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Hui Zhang
- Key Laboratory of Luminescent and Real-Time analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Qianqian Sun
- Key Laboratory of Luminescent and Real-Time analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Xiaoli Hu
- Key Laboratory of Luminescent and Real-Time analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China.
| |
Collapse
|
197
|
Musumeci T, Leonardi A, Bonaccorso A, Pignatello R, Puglisi G. Tangential Flow Filtration Technique: An Overview on Nanomedicine Applications. Pharm Nanotechnol 2018; 6:48-60. [PMID: 29510657 DOI: 10.2174/2211738506666180306160921] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2017] [Revised: 12/04/2017] [Accepted: 01/04/2018] [Indexed: 06/08/2023]
Abstract
Purification is a key step for different types of approaches, ranging from food, biotechnology to pharmaceutical fields. In biotechnology, tangential flow filtration (TFF) allows obtaining the separation of different components of cells without instability phenomena. In the food industry, TFF ensures the removal of contaminants or other substances that negatively affect visual appearance, organoleptic attributes, nutritional value and/or safety of ailments. In the pharmaceutical area, purification is also an important and necessary step controlling the quality of final product. In the field of research and development of nanomedicines, several techniques are used to purify and/or to concentrate the batches for in vitro and in vivo applications. Despite many approaches that exist; current data reveal continued unsatisfactory results. Between them, TFF showed promising results, even if, currently, its use is uncommon if compared with other purification techniques usually reported in "materials and methods" sections. This review represents an overview of the different applications of TFF from protein purification to food application, with particular attention to the field of nanomedicine from polymeric to metallic nanoparticles, highlighting advantages and dis-advantages in the use of this technique. The theoretical aspect of the process has been examined.
Collapse
Affiliation(s)
- Teresa Musumeci
- Department of Drug Sciences, Research Centre on Ocular Nanotechnology (NANO-i), University of Catania, Catania, Italy
| | - Antonio Leonardi
- Department of Drug Sciences, Research Centre on Ocular Nanotechnology (NANO-i), University of Catania, Catania, Italy
| | - Angela Bonaccorso
- Department of Drug Sciences, Research Centre on Ocular Nanotechnology (NANO-i), University of Catania, Catania, Italy
| | - Rosario Pignatello
- Department of Drug Sciences, Research Centre on Ocular Nanotechnology (NANO-i), University of Catania, Catania, Italy
| | - Giovanni Puglisi
- Department of Drug Sciences, Research Centre on Ocular Nanotechnology (NANO-i), University of Catania, Catania, Italy
| |
Collapse
|
198
|
Sreeda P, Sathya AB, Sivasubramanian V. Novel application of high-density polyethylene mesh as self-forming dynamic membrane integrated into a bioreactor for wastewater treatment. Environ Technol 2018; 39:51-58. [PMID: 28278776 DOI: 10.1080/09593330.2017.1294623] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Accepted: 02/08/2017] [Indexed: 06/06/2023]
Abstract
In the present study, self-forming dynamic membrane (SFDM) on rigid high-density polyethylene (HDPE) mesh with a large pore size of 2 mm is reported for the first time. The system was investigated for utilisation in simulated wastewater treatment by integrating the mesh with an aerobic bioreactor. The SFDM was analysed using Fourier transform infra-red (FT-IR) spectroscopy and visualised by scanning electron microscopy (SEM). The effect of the operating parameter on the change in composition of SFDM was also investigated. The system was used as a single unit for treatment of wastewater and showed stability over long-term treatment. The system could achieve a chemical oxygen demand (COD) reduction of 82.16 ± 6.47% at an influent COD concentration of 613.93 ± 72.13 mg/l and ammonia removal efficiency of 97.21 ± 0.62% at an influent ammonia concentration of 55.54 ± 2.23 mg/l. The reactor generated high-quality effluent and the turbidity recorded was less than 2NTU. In addition, the operational parameters, namely hydraulic retention time and organic loading rate, were optimised.
Collapse
Affiliation(s)
- P Sreeda
- a Department of Chemical Engineering , National Institute of Technology Calicut, Kozhikode , Kerala , India
| | - A B Sathya
- a Department of Chemical Engineering , National Institute of Technology Calicut, Kozhikode , Kerala , India
| | - V Sivasubramanian
- a Department of Chemical Engineering , National Institute of Technology Calicut, Kozhikode , Kerala , India
| |
Collapse
|
199
|
Kim JE, Phuntsho S, Ali SM, Choi JY, Shon HK. Forward osmosis membrane modular configurations for osmotic dilution of seawater by forward osmosis and reverse osmosis hybrid system. Water Res 2018; 128:183-192. [PMID: 29102697 DOI: 10.1016/j.watres.2017.10.042] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2017] [Revised: 10/14/2017] [Accepted: 10/19/2017] [Indexed: 06/07/2023]
Abstract
This study evaluates various options for full-scale modular configuration of forward osmosis (FO) process for osmotic dilution of seawater using wastewater for simultaneous desalination and water reuse through FO-reverse osmosis (RO) hybrid system. Empirical relationship obtained from one FO membrane element operation was used to simulate the operational performances of different FO module configurations. The main limiting criteria for module operation is to always maintain the feed pressure higher than the draw pressure throughout the housing module for safe operation without affecting membrane integrity. Experimental studies under the conditions tested in this study show that a single membrane housing cannot accommodate more than four elements as the draw pressure exceeds the feed pressure. This then indicates that a single stage housing with eight elements is not likely to be practical for safe FO operation. Hence, six different FO modular configurations were proposed and simulated. A two-stage FO configuration with multiple housings (in parallel) in the second stage using same or larger spacer thickness reduces draw pressure build-up as the draw flow rates are reduced to half in the second stage thereby allowing more than four elements in the second stage housing. The loss of feed pressure (pressure drop) and osmotic driving force in the second stage are compensated by operating under the pressure assisted osmosis (PAO) mode, which helps enhance permeate flux and maintains positive pressure differences between the feed and draw chamber. The PAO energy penalty is compensated by enhanced permeate throughput, reduced membrane area, and plant footprint. The contribution of FO/PAO to total energy consumption was not significant compared to post RO desalination (90%) indicating that the proposed two-stage FO modular configuration is one way of making the FO full-scale operation practical for FO-RO hybrid system.
Collapse
Affiliation(s)
- Jung Eun Kim
- School of Civil and Environmental Engineering, University of Technology, Sydney, Post Box 129, Broadway, NSW, 2007, Australia
| | - Sherub Phuntsho
- School of Civil and Environmental Engineering, University of Technology, Sydney, Post Box 129, Broadway, NSW, 2007, Australia.
| | - Syed Muztuza Ali
- School of Civil and Environmental Engineering, University of Technology, Sydney, Post Box 129, Broadway, NSW, 2007, Australia
| | - Joon Young Choi
- Hyorim Industries Inc., Yatap-dong, Bundang-gu, Seongnam-city, 513-2, Gyeonggi-do, Republic of Korea
| | - Ho Kyong Shon
- School of Civil and Environmental Engineering, University of Technology, Sydney, Post Box 129, Broadway, NSW, 2007, Australia.
| |
Collapse
|
200
|
Alexander BM, Esswein EJ, Gressel MG, Kratzer JL, Feng HA, Miller AL, Cauda E, Heil G. Evaluation of an improved prototype mini-baghouse to control the release of respirable crystalline silica from sand movers. J Occup Environ Hyg 2018; 15:24-37. [PMID: 29053936 DOI: 10.1080/15459624.2017.1376068] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The OSHA final rule on respirable crystalline silica (RCS) will require hydraulic fracturing companies to implement engineering controls to limit workers' exposure to RCS. RCS is generated by pneumatic transfer of quartz-containing sand during hydraulic fracturing operations. Chronic inhalation of RCS can lead to serious disease, including silicosis and lung cancer. NIOSH research identified at least seven sources where RCS aerosols were generated at hydraulic fracturing sites. NIOSH researchers developed an engineering control to address one of the largest sources of RCS aerosol generation, RCS escaping from thief hatches on the top of sand movers. The control, the NIOSH Mini-Baghouse Retrofit Assembly (NMBRA), mounts on the thief hatches. Unlike most commercially available engineering controls, the NMBRA has no moving parts and requires no power source. This article details the results of an evaluation of generation 3 of the NMBRA at a sand mine in Arkansas from May 19-21, 2015. During the evaluation, 168 area air samples were collected at 12 locations on and around a sand mover with and without the NMBRA installed. Analytical results for respirable dust and RCS indicated the use of the NMBRA effectively reduced concentrations of both respirable dust and RCS downwind of the thief hatches. Reductions of airborne respirable dust were estimated at 99+%; reductions in airborne RCS ranged from 98-99%. Analysis of bulk samples of the dust showed the likely presence of freshly fractured quartz, a particularly hazardous form of RCS. Use of an improved filter fabric and a larger area of filter cloth led to substantial improvements in filtration and pressures during these trials, as compared to the generation 2 NMBRA. Planned future design enhancements, including a weather cover, will increase the performance and durability of the NMBRA. Future trials are planned to evaluate the long-term operability of the technology.
Collapse
Affiliation(s)
- Barbara M Alexander
- a National Institute for Occupational Safety and Health , Division of Applied Research and Technology , Cincinnati , Ohio
| | - Eric J Esswein
- b National Institute for Occupational Safety and Health , Western States Division , Denver , Colorado
- c University of the Witwatersrand, School of Public Health , Johannesburg , South Africa
| | - Michael G Gressel
- a National Institute for Occupational Safety and Health , Division of Applied Research and Technology , Cincinnati , Ohio
| | - Jerry L Kratzer
- a National Institute for Occupational Safety and Health , Division of Applied Research and Technology , Cincinnati , Ohio
| | - H Amy Feng
- a National Institute for Occupational Safety and Health , Division of Applied Research and Technology , Cincinnati , Ohio
| | - Arthur L Miller
- d National Institute for Occupational Safety and Health , Spokane Mining Research Division , Spokane , Washington
| | - Emanuele Cauda
- e National Institute for Occupational Safety and Health , Pittsburgh Mining Research Division , Pittsburgh , Pennsylvania
| | - Graeham Heil
- a National Institute for Occupational Safety and Health , Division of Applied Research and Technology , Cincinnati , Ohio
| |
Collapse
|