251
|
Cabrera L, Sadle C, Purcell E. Neuroethical considerations of high-density electrode arrays. Nat Biomed Eng 2019; 3:586-589. [DOI: 10.1038/s41551-019-0407-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
252
|
Wu X, Peng H. Polymer-based flexible bioelectronics. Sci Bull (Beijing) 2019; 64:634-640. [PMID: 36659632 DOI: 10.1016/j.scib.2019.04.011] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 03/17/2019] [Accepted: 03/18/2019] [Indexed: 01/21/2023]
Abstract
Due to the mechanical mismatch between conventional rigid electronic devices and soft tissues at nature, a lot of interests have been attracted to develop flexible bioelectronics that work well both in vitro and in vivo. To this end, polymers that can be used for both key components and substrates are indispensable to achieve high performances such as high sensitivity and long-term stability for sensing applications. Here we will summarize the recent advances on the synthesis of a variety of polymers, the design of typical architectures and the integration of different functions for the flexible bioelectronic devices. The remaining challenges and promising directions are highlighted to provide inspirations for the future study on the emerging flexible bioelectronics at end.
Collapse
Affiliation(s)
- Xiaoying Wu
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai 200438, China
| | - Huisheng Peng
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai 200438, China.
| |
Collapse
|
253
|
Lee M, Shim HJ, Choi C, Kim DH. Soft High-Resolution Neural Interfacing Probes: Materials and Design Approaches. NANO LETTERS 2019; 19:2741-2749. [PMID: 31002760 DOI: 10.1021/acs.nanolett.8b04895] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Neural interfacing probes are located between the nervous system and the implanted electronic device in order to acquire information on the complex neuronal activity and to reconstruct impaired neural connectivity. Despite remarkable advancement in recent years, conventional neural interfacing is still unable to completely accomplish these goals, especially in long-term brain interfacing. The major limitation arises from physical and mechanical differences between neural interfacing probes and neural tissues that cause local immune responses and production of scar cells near the interface. Therefore, neural interfaces should ideally be extremely soft and have the physical scale of cells to mitigate the boundary between biotic and abiotic systems. Soft materials for neural interfaces have been intensively investigated to improve both interfacing and long-term signal transmission. The design and fabrication of micro and nanoscale devices have drastically decreased the stiffness of probes and enabled single-neuron measurement. In this Mini Review, we discuss materials and design approaches for developing soft high-resolution neural probes intended for long-term brain interfacing and outline existent challenges for achieving next-generation neural interfacing probes.
Collapse
Affiliation(s)
- Mincheol Lee
- Center for Nanoparticle Research , Institute for Basic Science (IBS) , Seoul 08826 , Republic of Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes , Seoul National University , Seoul 08826 , Republic of Korea
| | - Hyung Joon Shim
- Center for Nanoparticle Research , Institute for Basic Science (IBS) , Seoul 08826 , Republic of Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes , Seoul National University , Seoul 08826 , Republic of Korea
| | - Changsoon Choi
- Center for Nanoparticle Research , Institute for Basic Science (IBS) , Seoul 08826 , Republic of Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes , Seoul National University , Seoul 08826 , Republic of Korea
| | - Dae-Hyeong Kim
- Center for Nanoparticle Research , Institute for Basic Science (IBS) , Seoul 08826 , Republic of Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes , Seoul National University , Seoul 08826 , Republic of Korea
| |
Collapse
|
254
|
Yang X, Zhou T, Zwang TJ, Hong G, Zhao Y, Viveros RD, Fu TM, Gao T, Lieber CM. Bioinspired neuron-like electronics. NATURE MATERIALS 2019; 18:510-517. [PMID: 30804509 PMCID: PMC6474791 DOI: 10.1038/s41563-019-0292-9] [Citation(s) in RCA: 208] [Impact Index Per Article: 34.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Accepted: 01/16/2019] [Indexed: 05/14/2023]
Abstract
As an important application of functional biomaterials, neural probes have contributed substantially to studying the brain. Bioinspired and biomimetic strategies have begun to be applied to the development of neural probes, although these and previous generations of probes have had structural and mechanical dissimilarities from their neuron targets that lead to neuronal loss, neuroinflammatory responses and measurement instabilities. Here, we present a bioinspired design for neural probes-neuron-like electronics (NeuE)-where the key building blocks mimic the subcellular structural features and mechanical properties of neurons. Full three-dimensional mapping of implanted NeuE-brain interfaces highlights the structural indistinguishability and intimate interpenetration of NeuE and neurons. Time-dependent histology and electrophysiology studies further reveal a structurally and functionally stable interface with the neuronal and glial networks shortly following implantation, thus opening opportunities for next-generation brain-machine interfaces. Finally, the NeuE subcellular structural features are shown to facilitate migration of endogenous neural progenitor cells, thus holding promise as an electrically active platform for transplantation-free regenerative medicine.
Collapse
Affiliation(s)
- Xiao Yang
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
| | - Tao Zhou
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
| | - Theodore J Zwang
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
| | - Guosong Hong
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
| | - Yunlong Zhao
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
| | - Robert D Viveros
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Tian-Ming Fu
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
| | - Teng Gao
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
| | - Charles M Lieber
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA.
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA.
- Center for Brain Science, Harvard University, Cambridge, MA, USA.
| |
Collapse
|
255
|
Kim T, Zhong Y, Giszter SF. Precise Tubular Braid Structures of Ultrafine Microwires as Neural Probes: Significantly Reduced Chronic Immune Response and Greater Local Neural Survival in Rat Cortex. IEEE Trans Neural Syst Rehabil Eng 2019; 27:846-856. [PMID: 30998475 DOI: 10.1109/tnsre.2019.2911912] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Braided multi-electrode probes (BMEPs) for neural interfaces comprise ultrafine microwire bundles interwoven into tubular braids. BMEPs provide highly flexible probes and tethers, and an open lattice structure with up to 24 recording/stimulating channels in precise geometries, currently all within a [Formula: see text] diameter footprint. This paper compares the long-term tissue effects of BMEPs ( [Formula: see text] wires) versus single conventional 50- [Formula: see text] wires, by testing nearby chronic immune response and neural survival in rat cortex. Four different types of electrodes were implanted in cortex in each of eight rats: 1) BMEP with tether; 2) tethered 50- [Formula: see text] wire; 3) BMEP without a tether; and 4) untethered 50- [Formula: see text] wire. Quantitative immunohistological statistical comparisons after eight weeks using GFAP, ED1, and NeuN staining clearly showed that both BMEP implants had significantly less tissue immune response and more neuronal survival than either of the 50- [Formula: see text] wires ( ) in each of the eight rats. Data strongly indicate that BMEP tissue responses are superior, and that BMEP designs partly alleviate chronic tissue inflammatory responses and neural losses. The flexible body, tether and open braid lattice, and finer wire diameters of BMEP designs may all contribute to reducing the biological long-term response.
Collapse
|
256
|
Wen X, Wang B, Huang S, Liu TL, Lee MS, Chung PS, Chow YT, Huang IW, Monbouquette HG, Maidment NT, Chiou PY. Flexible, multifunctional neural probe with liquid metal enabled, ultra-large tunable stiffness for deep-brain chemical sensing and agent delivery. Biosens Bioelectron 2019; 131:37-45. [PMID: 30818131 PMCID: PMC6602555 DOI: 10.1016/j.bios.2019.01.060] [Citation(s) in RCA: 67] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 01/21/2019] [Accepted: 01/24/2019] [Indexed: 10/27/2022]
Abstract
Flexible neural probes have been pursued previously to minimize the mechanical mismatch between soft neural tissues and implants and thereby improve long-term performance. However, difficulties with insertion of such probes deep into the brain severely restricts their utility. We describe a solution to this problem using gallium (Ga) in probe construction, taking advantage of the solid-to-liquid phase change of the metal at body temperature and probe shape deformation to provide temperature-dependent control of stiffness over 5 orders of magnitude. Probes in the stiff state were successfully inserted 2 cm-deep into agarose gel "brain phantoms" and into rat brains under cooled conditions where, upon Ga melting, they became ultra soft, flexible, and stretchable in all directions. The current 30 μm-thick probes incorporated multilayer, deformable microfluidic channels for chemical agent delivery, electrical interconnects through Ga wires, and high-performance electrochemical glutamate sensing. These PDMS-based microprobes of ultra-large tunable stiffness (ULTS) should serve as an attractive platform for multifunctional chronic neural implants.
Collapse
Affiliation(s)
- Ximiao Wen
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, Los Angeles, CA, USA
| | - Bo Wang
- Department of Psychiatry & Biobehavioral Sciences, Semel Institute for Neuroscience and Human Behavior, University of California at Los Angeles, CA, USA
| | - Shan Huang
- Department of Biological Chemistry, University of California at Los Angeles, CA, USA
| | - Tingyi Leo Liu
- Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, MA, USA
| | - Meng-Shiue Lee
- Department of Mechanical Engineering, National Chiao Tung University, Hsinchu, Taiwan
| | - Pei-Shan Chung
- Department of Bioengineering, University of California at Los Angeles, CA, USA
| | - Yu Ting Chow
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, Los Angeles, CA, USA
| | - I-Wen Huang
- Department of Chemical and Biomolecular Engineering, University of California at Los Angeles, CA, USA
| | - Harold G Monbouquette
- Department of Chemical and Biomolecular Engineering, University of California at Los Angeles, CA, USA
| | - Nigel T Maidment
- Department of Psychiatry & Biobehavioral Sciences, Semel Institute for Neuroscience and Human Behavior, University of California at Los Angeles, CA, USA.
| | - Pei-Yu Chiou
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, Los Angeles, CA, USA; Department of Bioengineering, University of California at Los Angeles, CA, USA.
| |
Collapse
|
257
|
Feiner R, Wertheim L, Gazit D, Kalish O, Mishal G, Shapira A, Dvir T. A Stretchable and Flexible Cardiac Tissue-Electronics Hybrid Enabling Multiple Drug Release, Sensing, and Stimulation. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1805526. [PMID: 30838769 PMCID: PMC7100044 DOI: 10.1002/smll.201805526] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2018] [Revised: 02/17/2019] [Indexed: 04/14/2023]
Abstract
Replacement of the damaged scar tissue created by a myocardial infarction is the goal of cardiac tissue engineering. However, once the implanted tissue is in place, monitoring its function is difficult and involves indirect methods, while intervention necessarily requires an invasive procedure and available medical attention. To overcome this, methods of integrating electronic components into engineered tissues have been recently presented. These allow for remote monitoring of tissue function as well as intervention through stimulation and controlled drug release. Here, an improved hybrid microelectronic tissue construct capable of withstanding the dynamic environment of the beating heart without compromising electronic or mechanical functionality is reported. While the reported system is enabled to sense the function of the engineered tissue and provide stimulation for pacing, an electroactive polymer on the electronics enables it to release multiple drugs in parallel. It is envisioned that the integration of microelectronic devices into engineered tissues will provide a better way to monitor patient health from afar, as well as provide facile, more exact methods to control the healing process.
Collapse
Affiliation(s)
- Ron Feiner
- School for Molecular Cell Biology and Biotechnology, Tel Aviv University, Tel Aviv 69978, Israel
- The Center for Nanoscience and Nanotechnology, Tel Aviv University, Tel Aviv 69978, Israel
| | - Lior Wertheim
- The Center for Nanoscience and Nanotechnology, Tel Aviv University, Tel Aviv 69978, Israel
- Department of Materials Science and Engineering, Tel Aviv University, Tel Aviv 69978, Israel
| | - Danielle Gazit
- School for Molecular Cell Biology and Biotechnology, Tel Aviv University, Tel Aviv 69978, Israel
| | - Or Kalish
- School for Molecular Cell Biology and Biotechnology, Tel Aviv University, Tel Aviv 69978, Israel
| | - Gal Mishal
- Department of Materials Science and Engineering, Tel Aviv University, Tel Aviv 69978, Israel
| | - Assaf Shapira
- School for Molecular Cell Biology and Biotechnology, Tel Aviv University, Tel Aviv 69978, Israel
| | - Tal Dvir
- School for Molecular Cell Biology and Biotechnology, Tel Aviv University, Tel Aviv 69978, Israel
- The Center for Nanoscience and Nanotechnology, Tel Aviv University, Tel Aviv 69978, Israel
- Department of Materials Science and Engineering, Tel Aviv University, Tel Aviv 69978, Israel
- Sagol Center for Regenerative Biotechnology, Tel Aviv University, Tel Aviv 69978, Israel
| |
Collapse
|
258
|
Martins NRB, Angelica A, Chakravarthy K, Svidinenko Y, Boehm FJ, Opris I, Lebedev MA, Swan M, Garan SA, Rosenfeld JV, Hogg T, Freitas RA. Human Brain/Cloud Interface. Front Neurosci 2019; 13:112. [PMID: 30983948 PMCID: PMC6450227 DOI: 10.3389/fnins.2019.00112] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Accepted: 01/30/2019] [Indexed: 12/25/2022] Open
Abstract
The Internet comprises a decentralized global system that serves humanity's collective effort to generate, process, and store data, most of which is handled by the rapidly expanding cloud. A stable, secure, real-time system may allow for interfacing the cloud with the human brain. One promising strategy for enabling such a system, denoted here as a "human brain/cloud interface" ("B/CI"), would be based on technologies referred to here as "neuralnanorobotics." Future neuralnanorobotics technologies are anticipated to facilitate accurate diagnoses and eventual cures for the ∼400 conditions that affect the human brain. Neuralnanorobotics may also enable a B/CI with controlled connectivity between neural activity and external data storage and processing, via the direct monitoring of the brain's ∼86 × 109 neurons and ∼2 × 1014 synapses. Subsequent to navigating the human vasculature, three species of neuralnanorobots (endoneurobots, gliabots, and synaptobots) could traverse the blood-brain barrier (BBB), enter the brain parenchyma, ingress into individual human brain cells, and autoposition themselves at the axon initial segments of neurons (endoneurobots), within glial cells (gliabots), and in intimate proximity to synapses (synaptobots). They would then wirelessly transmit up to ∼6 × 1016 bits per second of synaptically processed and encoded human-brain electrical information via auxiliary nanorobotic fiber optics (30 cm3) with the capacity to handle up to 1018 bits/sec and provide rapid data transfer to a cloud based supercomputer for real-time brain-state monitoring and data extraction. A neuralnanorobotically enabled human B/CI might serve as a personalized conduit, allowing persons to obtain direct, instantaneous access to virtually any facet of cumulative human knowledge. Other anticipated applications include myriad opportunities to improve education, intelligence, entertainment, traveling, and other interactive experiences. A specialized application might be the capacity to engage in fully immersive experiential/sensory experiences, including what is referred to here as "transparent shadowing" (TS). Through TS, individuals might experience episodic segments of the lives of other willing participants (locally or remote) to, hopefully, encourage and inspire improved understanding and tolerance among all members of the human family.
Collapse
Affiliation(s)
- Nuno R. B. Martins
- Lawrence Berkeley National Laboratory, Berkeley, CA, United States
- Center for Research and Education on Aging (CREA), University of California, Berkeley and LBNL, Berkeley, CA, United States
| | | | - Krishnan Chakravarthy
- UC San Diego Health Science, San Diego, CA, United States
- VA San Diego Healthcare System, San Diego, CA, United States
| | | | | | - Ioan Opris
- Miami Project to Cure Paralysis, University of Miami, Miami, FL, United States
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, United States
| | - Mikhail A. Lebedev
- Center for Neuroengineering, Duke University, Durham, NC, United States
- Center for Bioelectric Interfaces of the Institute for Cognitive Neuroscience of the National Research University Higher School of Economics, Moscow, Russia
- Department of Information and Internet Technologies of Digital Health Institute, I.M. Sechenov First Moscow State Medical University, Moscow, Russia
| | - Melanie Swan
- Department of Philosophy, Purdue University, West Lafayette, IN, United States
| | - Steven A. Garan
- Lawrence Berkeley National Laboratory, Berkeley, CA, United States
- Center for Research and Education on Aging (CREA), University of California, Berkeley and LBNL, Berkeley, CA, United States
| | - Jeffrey V. Rosenfeld
- Monash Institute of Medical Engineering, Monash University, Clayton, VIC, Australia
- Department of Neurosurgery, Alfred Hospital, Melbourne, VIC, Australia
- Department of Surgery, Monash University, Clayton, VIC, Australia
- Department of Surgery, F. Edward Hébert School of Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD, United States
| | - Tad Hogg
- Institute for Molecular Manufacturing, Palo Alto, CA, United States
| | | |
Collapse
|
259
|
Choi S, Han SI, Kim D, Hyeon T, Kim DH. High-performance stretchable conductive nanocomposites: materials, processes, and device applications. Chem Soc Rev 2019; 48:1566-1595. [PMID: 30519703 DOI: 10.1039/c8cs00706c] [Citation(s) in RCA: 236] [Impact Index Per Article: 39.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Highly conductive and intrinsically stretchable electrodes are vital components of soft electronics such as stretchable transistors and circuits, sensors and actuators, light-emitting diode arrays, and energy harvesting devices. Many kinds of conducting nanomaterials with outstanding electrical and mechanical properties have been integrated with elastomers to produce stretchable conductive nanocomposites. Understanding the characteristics of these nanocomposites and assessing the feasibility of their fabrication are therefore critical for the development of high-performance stretchable conductors and electronic devices. We herein summarise the recent advances in stretchable conductors based on the percolation networks of nanoscale conductive fillers in elastomeric media. After discussing the material-, dimension-, and size-dependent properties of conductive fillers and their implications, we highlight various techniques that are used to reduce the contact resistance between the conductive filler materials. Furthermore, we categorize elastomer matrices with different stretchabilities and mechanical properties based on their polymeric chain structures. Then, we discuss the fabrication techniques of stretchable conductive nanocomposites toward their use in soft electronics. Finally, we provide representative examples of stretchable device applications and conclude the review with a brief outlook for future research.
Collapse
Affiliation(s)
- Suji Choi
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea
| | | | | | | | | |
Collapse
|
260
|
Sanjuan-Alberte P, Saleh E, Shaw AJ, Lacalendola N, Willmott G, Vaithilingam J, Alexander MR, Hague RJM, Rawson FJ. Remotely Controlled in Situ Growth of Silver Microwires Forming Bioelectronic Interfaces. ACS APPLIED MATERIALS & INTERFACES 2019; 11:8928-8936. [PMID: 30735349 DOI: 10.1021/acsami.8b22075] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
There is a pressing need to advance our ability to construct three-dimensional (3D) functional bioelectronic interfaces. Additionally, to ease the transition to building cellular electronic systems, a remote approach to merge electrical components with biology is desirable. By combining 3D digital inkjet printing with bipolar electrochemistry, we remotely control and fabricate conductive wires, forming a first of its kind contactless bionic manufacturing procedure. It enables controlled fabrication of conductive wires in a three-dimensional configuration. Moreover, we demonstrate that this technology could be used to grow and interface conductive conduits in situ with mammalian cells, offering a new strategy to engineering bioelectronic interfaces. This represents a step change in the production of functional complex circuitry and considerably increases the manufacturing capabilities of merging cells with electronics. This approach provides a platform to construct bioelectronics in situ offering a potential paradigm shift in the methods for building bioelectronics with potential applications in biosensing and bioelectronic medicine.
Collapse
Affiliation(s)
| | | | | | - Nicola Lacalendola
- The MacDiarmid Institute for Advanced Materials and Technology, Department of Physics and Chemistry , The University of Auckland , Auckland 1010 , New Zealand
| | - Geoff Willmott
- The MacDiarmid Institute for Advanced Materials and Technology, Department of Physics and Chemistry , The University of Auckland , Auckland 1010 , New Zealand
| | | | | | | | | |
Collapse
|
261
|
Kim C, Jeong J, Kim SJ. Recent Progress on Non-Conventional Microfabricated Probes for the Chronic Recording of Cortical Neural Activity. SENSORS (BASEL, SWITZERLAND) 2019; 19:E1069. [PMID: 30832357 PMCID: PMC6427797 DOI: 10.3390/s19051069] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 02/25/2019] [Accepted: 02/26/2019] [Indexed: 02/06/2023]
Abstract
Microfabrication technology for cortical interfaces has advanced rapidly over the past few decades for electrophysiological studies and neuroprosthetic devices offering the precise recording and stimulation of neural activity in the cortex. While various cortical microelectrode arrays have been extensively and successfully demonstrated in animal and clinical studies, there remains room for further improvement of the probe structure, materials, and fabrication technology, particularly for high-fidelity recording in chronic implantation. A variety of non-conventional probes featuring unique characteristics in their designs, materials and fabrication methods have been proposed to address the limitations of the conventional standard shank-type ("Utah-" or "Michigan-" type) devices. Such non-conventional probes include multi-sided arrays to avoid shielding and increase recording volumes, mesh- or thread-like arrays for minimized glial scarring and immune response, tube-type or cylindrical probes for three-dimensional (3D) recording and multi-modality, folded arrays for high conformability and 3D recording, self-softening or self-deployable probes for minimized tissue damage and extensions of the recording sites beyond gliosis, nanostructured probes to reduce the immune response, and cone-shaped electrodes for promoting tissue ingrowth and long-term recording stability. Herein, the recent progress with reference to the many different types of non-conventional arrays is reviewed while highlighting the challenges to be addressed and the microfabrication techniques necessary to implement such features.
Collapse
Affiliation(s)
- Chaebin Kim
- Department of Electrical and Computer Engineering, Seoul National University, Seoul 08826, Korea.
| | - Joonsoo Jeong
- Department of Biomedical Engineering, School of Medicine, Pusan National University, Yangsan 50612, Korea.
| | - Sung June Kim
- Department of Electrical and Computer Engineering, Seoul National University, Seoul 08826, Korea.
- Institute on Aging, College of Medicine, Seoul National University, Seoul 08826, Korea.
| |
Collapse
|
262
|
Guan S, Wang J, Gu X, Zhao Y, Hou R, Fan H, Zou L, Gao L, Du M, Li C, Fang Y. Elastocapillary self-assembled neurotassels for stable neural activity recordings. SCIENCE ADVANCES 2019; 5:eaav2842. [PMID: 30944856 PMCID: PMC6436924 DOI: 10.1126/sciadv.aav2842] [Citation(s) in RCA: 110] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2018] [Accepted: 02/06/2019] [Indexed: 05/18/2023]
Abstract
Implantable neural probes that are mechanically compliant with brain tissue offer important opportunities for stable neural interfaces in both basic neuroscience and clinical applications. Here, we developed a Neurotassel consisting of an array of flexible and high-aspect ratio microelectrode filaments. A Neurotassel can spontaneously assemble into a thin and implantable fiber through elastocapillary interactions when withdrawn from a molten, tissue-dissolvable polymer. Chronically implanted Neurotassels elicited minimal neuronal cell loss in the brain and enabled stable activity recordings of the same population of neurons in mice learning to perform a task. Moreover, Neurotassels can be readily scaled up to 1024 microelectrode filaments, each with a neurite-scale cross-sectional footprint of 3 × 1.5 μm2, to form implantable fibers with a total diameter of ~100 μm. With their ultrasmall sizes, high flexibility, and scalability, Neurotassels offer a new approach for stable neural activity recording and neuroprosthetics.
Collapse
Affiliation(s)
- S. Guan
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China
- CAS Center for Excellence in Brain Science and Intelligence Technology, Institute of Neuroscience, Shanghai Institutes for Biological Sciences, Chinese Academy of Sciences, Shanghai 200031, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - J. Wang
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China
- CAS Center for Excellence in Brain Science and Intelligence Technology, Institute of Neuroscience, Shanghai Institutes for Biological Sciences, Chinese Academy of Sciences, Shanghai 200031, China
| | - X. Gu
- CAS Center for Excellence in Brain Science and Intelligence Technology, Institute of Neuroscience, Shanghai Institutes for Biological Sciences, Chinese Academy of Sciences, Shanghai 200031, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Y. Zhao
- College of Mechanical and Vehicle Engineering, Hunan University, Changsha 410082, China
| | - R. Hou
- CAS Center for Excellence in Brain Science and Intelligence Technology, Institute of Neuroscience, Shanghai Institutes for Biological Sciences, Chinese Academy of Sciences, Shanghai 200031, China
| | - H. Fan
- CAS Center for Excellence in Brain Science and Intelligence Technology, Institute of Neuroscience, Shanghai Institutes for Biological Sciences, Chinese Academy of Sciences, Shanghai 200031, China
| | - L. Zou
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - L. Gao
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - M. Du
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - C. Li
- CAS Center for Excellence in Brain Science and Intelligence Technology, Institute of Neuroscience, Shanghai Institutes for Biological Sciences, Chinese Academy of Sciences, Shanghai 200031, China
- Corresponding author. (C.L.); (Y.F.)
| | - Y. Fang
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China
- CAS Center for Excellence in Brain Science and Intelligence Technology, Institute of Neuroscience, Shanghai Institutes for Biological Sciences, Chinese Academy of Sciences, Shanghai 200031, China
- Corresponding author. (C.L.); (Y.F.)
| |
Collapse
|
263
|
Yasui T, Yanagida T, Shimada T, Otsuka K, Takeuchi M, Nagashima K, Rahong S, Naito T, Takeshita D, Yonese A, Magofuku R, Zhu Z, Kaji N, Kanai M, Kawai T, Baba Y. Engineering Nanowire-Mediated Cell Lysis for Microbial Cell Identification. ACS NANO 2019; 13:2262-2273. [PMID: 30758938 DOI: 10.1021/acsnano.8b08959] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Researchers have demonstrated great promise for inorganic nanowire use in analyzing cells or intracellular components. Although a stealth effect of nanowires toward cell surfaces allows preservation of the living intact cells when analyzing cells, as a completely opposite approach, the applicability to analyze intracellular components through disrupting cells is also central to understanding cellular information. However, the reported lysis strategy is insufficient for microbial cell lysis due to the cell robustness and wrong approach taken so far ( i. e., nanowire penetration into a cell membrane). Here we propose a nanowire-mediated lysis method for microbial cells by introducing the rupture approach initiated by cell membrane stretching; in other words, the nanowires do not penetrate the membrane, but rather they break the membrane between the nanowires. Entangling cells with the bacteria-compatible and flexible nanowires and membrane stretching of the entangled cells, induced by the shear force, play important roles for the nanowire-mediated lysis to Gram-positive and Gram-negative bacteria and yeast cells. Additionally, the nanowire-mediated lysis is readily compatible with the loop-mediated isothermal amplification (LAMP) method because the lysis is triggered by simply introducing the microbial cells. We show that an integration of the nanowire-mediated lysis with LAMP provides a means for a simple, rapid, one-step identification assay (just introducing a premixed solution into a device), resulting in visual chromatic identification of microbial cells. This approach allows researchers to develop a microfluidic analytical platform not only for microbial cell identification including drug- and heat-resistance cells but also for on-site detection without any contamination.
Collapse
Affiliation(s)
- Takao Yasui
- Japan Science and Technology Agency (JST), Precursory Research for Embryonic Science and Technology (PRESTO) , 4-1-8 Honcho , Kawaguchi , Saitama 332-0012 , Japan
| | - Takeshi Yanagida
- Institute of Materials Chemistry and Engineering , Kyushu University , 6-1 Kasuga-Koen , Kasuga, Fukuoka 816-8580 , Japan
- Institute of Scientific and Industrial Research , Osaka University , 8-1 Mihogaoka-cho , Ibaraki, Osaka 567-0047 , Japan
| | | | | | | | - Kazuki Nagashima
- Institute of Materials Chemistry and Engineering , Kyushu University , 6-1 Kasuga-Koen , Kasuga, Fukuoka 816-8580 , Japan
| | - Sakon Rahong
- College of Nanotechnology , King Mongkut's Institute of Technology Ladkrabang , Chalongkrung Rd. , Ladkrabang, Bangkok 10520 , Thailand
| | - Toyohiro Naito
- Department of Material Chemistry, Graduate School of Engineering , Kyoto University , Katsura, Nishikyo-ku, Kyoto 615-8510 , Japan
| | | | | | | | - Zetao Zhu
- Institute of Materials Chemistry and Engineering , Kyushu University , 6-1 Kasuga-Koen , Kasuga, Fukuoka 816-8580 , Japan
| | - Noritada Kaji
- Japan Science and Technology Agency (JST), Precursory Research for Embryonic Science and Technology (PRESTO) , 4-1-8 Honcho , Kawaguchi , Saitama 332-0012 , Japan
- Department of Chemistry and Biochemistry, Graduate School of Engineering , Kyushu University , Moto-oka 744 , Nishi-ku, Fukuoka 819-0395 , Japan
| | - Masaki Kanai
- Institute of Materials Chemistry and Engineering , Kyushu University , 6-1 Kasuga-Koen , Kasuga, Fukuoka 816-8580 , Japan
| | - Tomoji Kawai
- Institute of Scientific and Industrial Research , Osaka University , 8-1 Mihogaoka-cho , Ibaraki, Osaka 567-0047 , Japan
| | - Yoshinobu Baba
- Health Research Institute , National Institute of Advanced Industrial Science and Technology (AIST) , Takamatsu 761-0395 , Japan
- College of Pharmacy , Kaohsiung Medical University , Kaohsiung 807 , 80708 Kaohsiung City , Taiwan , R.O.C
| |
Collapse
|
264
|
Advances in materials for cellular applications (Review). Biointerphases 2019; 14:010801. [PMID: 30803241 DOI: 10.1116/1.5083803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The goal of this review is to highlight materials that show exciting promise for either entirely new cellular-level applications or new approaches to long-standing biological challenges. The authors start with two more established materials, graphene and carbon nanotubes, and then progress to conducting polymers, followed by an overview of the microresonators, nanowires, and spasers used as intracellular lasers. These materials provide new approaches to gene and drug delivery, cellular regeneration, mechanical sensing, imaging, and the modulation and recording of cellular activity. Of specific interest is the comparison of these materials with existing technologies, the method of cellular delivery, and the all-encompassing challenge of biocompatibility. Concluding remarks examine the extension of these materials from cellular-level experiments to in vivo applications, including the method of activation: light, electricity, and ultrasound. Overall, these materials and their associated applications illustrate the most recent advances in material-cell interactions.
Collapse
|
265
|
Kim J, Kim HR, Lee HC, Kim KH, Hwang MS, Lee JM, Jeong KY, Park HG. Photon-Triggered Current Generation in Chemically-Synthesized Silicon Nanowires. NANO LETTERS 2019; 19:1269-1274. [PMID: 30677304 DOI: 10.1021/acs.nanolett.8b04843] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
A porous Si segment in a Si nanowire (NW), when exposed to light, generates a current with a high on/off ratio. This unique feature has been recently used to demonstrate photon-triggered NW devices including transistors, logic gates, and photodetection systems. Here, we develop a reliable and simple procedure to fabricate porous Si segments in chemically synthesized Si NWs for photon-triggered current generation. To achieve this, we employ 100 nm-diameter chemical-vapor-deposition grown Si NWs that possess an n-type high doping level and extremely smooth surface. The NW regions uncovered by electron-beam resist become selectively porous through metal-assisted chemical etching, using Ag nanoparticles as a catalyst. The contact electrodes are then fabricated on both ends of such NWs, and the generated current is measured when the laser is focused on the porous Si segment. The current level is changed by controlling the power of the incident laser and bias voltage. The on/off ratio is measured up to 1.5 × 104 at a forward bias of 5 V. In addition, we investigate the porous-length-dependent responsivity of the NW device with the porous Si segment. The responsivity is observed to decrease for porous segment lengths beyond 360 nm. Furthermore, we fabricate nine porous Si segments in a single Si NW and measure the identical photon-triggered current from each porous segment; this single NW device can function as a high-resolution photodetection system. Therefore, our fabrication method to precisely control the position and length of the porous Si segments opens up new possibilities for the practical implementation of programmable logic gates and ultrasensitive photodetectors.
Collapse
Affiliation(s)
- Jungkil Kim
- Department of Physics , Korea University , Seoul 02841 , Korea
- Department of Chemistry , Johns Hopkins University , Baltimore , Maryland 21218 , United States
| | - Ha-Reem Kim
- Department of Physics , Korea University , Seoul 02841 , Korea
| | - Hoo-Cheol Lee
- Department of Physics , Korea University , Seoul 02841 , Korea
| | - Kyoung-Ho Kim
- Department of Physics , Chungbuk National University , Cheongju 28644 , Korea
| | - Min-Soo Hwang
- Department of Physics , Korea University , Seoul 02841 , Korea
| | - Jung Min Lee
- Department of Physics , Korea University , Seoul 02841 , Korea
| | | | - Hong-Gyu Park
- Department of Physics , Korea University , Seoul 02841 , Korea
- KU-KIST Graduate School of Converging Science and Technology , Korea University , Seoul 02841 , Korea
- Center for Molecular Spectroscopy and Dynamics , Institute for Basic Science , Seoul 02841 , Korea
| |
Collapse
|
266
|
Zhao Z, Li X, He F, Wei X, Lin S, Xie C. Parallel, minimally-invasive implantation of ultra-flexible neural electrode arrays. J Neural Eng 2019; 16:035001. [PMID: 30736013 DOI: 10.1088/1741-2552/ab05b6] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVE Implanted microelectrodes provide a unique means to directly interface with the nervous system but have been limited by the lack of stable functionality. There is growing evidence suggesting that substantially reducing the mechanical rigidity of neural electrodes promotes tissue compatibility and improves their recording stability in both the short- and long-term. However, the miniaturized dimensions and ultraflexibility desired for mitigating tissue responses preclude the probe's self-supported penetration into the brain tissue. APPROACH Here we demonstrate the high-throughput implantation of multi-shank ultraflexible neural electrode arrays with surgical footprints as small as 200 µm2 in a mouse model. This is achieved by using arrays of tungsten microwires as shuttle devices, and bio-dissolvable adhesive polyethylene glycol (PEG) to temporarily attach a shank onto each microwire. MAIN RESULTS We show the ability to simultaneously deliver electrode arrays in designed patterns, to adjust the implantation locations of the shanks by need, to target different brain structures, and to control the surgical injury by reducing the microwire diameters to cellular scale. SIGNIFICANCE These results provide a facile implantation method to apply ultraflexible neural probes in scalable neural recording.
Collapse
Affiliation(s)
- Zhengtuo Zhao
- Department of Biomedical Engineering, the University of Texas at Austin, Austin, TX 78712, United States of America
| | | | | | | | | | | |
Collapse
|
267
|
Ghanbari L, Rynes ML, Hu J, Schulman DS, Johnson GW, Laroque M, Shull GM, Kodandaramaiah SB. Craniobot: A computer numerical controlled robot for cranial microsurgeries. Sci Rep 2019; 9:1023. [PMID: 30705287 PMCID: PMC6355931 DOI: 10.1038/s41598-018-37073-w] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2018] [Accepted: 11/30/2018] [Indexed: 12/11/2022] Open
Abstract
Over the last few decades, a plethora of tools has been developed for neuroscientists to interface with the brain. Implementing these tools requires precisely removing sections of the skull to access the brain. These delicate cranial microsurgical procedures need to be performed on the sub-millimeter thick bone without damaging the underlying tissue and therefore, require significant training. Automating some of these procedures would not only enable more precise microsurgical operations, but also facilitate widespread use of advanced neurotechnologies. Here, we introduce the "Craniobot", a cranial microsurgery platform that combines automated skull surface profiling with a computer numerical controlled (CNC) milling machine to perform a variety of cranial microsurgical procedures on mice. The Craniobot utilizes a low-force contact sensor to profile the skull surface and uses this information to perform precise milling operations within minutes. We have used the Craniobot to perform intact skull thinning and open small to large craniotomies over the dorsal cortex.
Collapse
Affiliation(s)
- Leila Ghanbari
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minnesota, USA
| | - Mathew L Rynes
- Department of Biomedical Engineering, University of Minnesota, Twin Cities, Minnesota, USA
| | - Jia Hu
- Department of Biomedical Engineering, University of Minnesota, Twin Cities, Minnesota, USA
| | - Daniel S Schulman
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minnesota, USA
| | - Gregory W Johnson
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minnesota, USA
| | - Michael Laroque
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minnesota, USA
| | - Gabriella M Shull
- Department of Biomedical Engineering, University of Minnesota, Twin Cities, Minnesota, USA
| | - Suhasa B Kodandaramaiah
- Department of Mechanical Engineering, University of Minnesota, Twin Cities, Minnesota, USA.
- Department of Biomedical Engineering, University of Minnesota, Twin Cities, Minnesota, USA.
| |
Collapse
|
268
|
Evaluating analgesic efficacy and administration route following craniotomy in mice using the grimace scale. Sci Rep 2019; 9:359. [PMID: 30674967 PMCID: PMC6344523 DOI: 10.1038/s41598-018-36897-w] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Accepted: 11/28/2018] [Indexed: 12/13/2022] Open
Abstract
Most research laboratories abide by guidelines and mandates set by their research institution regarding the administration of analgesics to control pain during the postoperative period. Unfortunately, measuring pain originating from the head is difficult, making adequate decisions regarding pain control following stereotaxic surgery problematic. In addition, most postsurgical analgesia protocols require multiple injections over several days, which may cause stress and distress during a critical recovery period. Here we sought to (1) assess the degree of postoperative pain following craniotomy in mice, (2) compare the efficacy of three common rodent analgesics (carprofen, meloxicam and buprenorphine) for reducing this pain and (3) determine whether the route of administration (injected or self-administered through the drinking supply) influenced pain relief post-craniotomy. Using the mouse grimace scale (MGS), we found that injectable analgesics were significantly more effective at relieving post-craniotomy pain, however, both routes of administration decreased pain scores in the first 24 h postsurgery. Specifically, buprenorphine administered independently of administration route was the most effective at reducing MGS scores, however, female mice showed greater sensitivity to carprofen when administered through the water supply. Although it is necessary to provide laboratory animals with analgesics after an invasive procedure, there remains a gap in the literature regarding the degree of craniotomy-related pain in rodents and the efficacy of alternative routes of administration. Our study highlights the limitations of administering drugs through the drinking supply, even at doses that are considered to be higher than those currently recommended by most research institutions for treating pain of mild to moderate severity.
Collapse
|
269
|
Veronica A, Li Y, Hsing I. Minimally Invasive & Long‐lasting Neural Probes from a Materials Perspective. ELECTROANAL 2019. [DOI: 10.1002/elan.201800719] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Asmita Veronica
- Department of Chemical and Biological EngineeringThe Hong Kong University of Science and Technology Kowloon Hong Kong
| | - Yue Li
- Department of Chemical and Biological EngineeringThe Hong Kong University of Science and Technology Kowloon Hong Kong
| | - I‐ming Hsing
- Department of Chemical and Biological EngineeringThe Hong Kong University of Science and Technology Kowloon Hong Kong
| |
Collapse
|
270
|
Zhao L, Zhang L, Zhao J, Shi J, Dai Z, Wang G, Zhang C, Li B, Feng X, Zhang H, Zhang J, Zhang Z. Engineering Surface Patterns with Shape Memory Polymers: Multiple Design Dimensions for Diverse and Hierarchical Structures. ACS APPLIED MATERIALS & INTERFACES 2019; 11:1563-1570. [PMID: 30499288 DOI: 10.1021/acsami.8b15535] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Deterministic design of surface patterns has seen a surge of interests because of their wide applications in flexible and stretchable electronics, microfluidics, and optical devices. Recently, instability of bilayer systems has been extensively utilized by which micro-/nano-patterns of a film can be easily achieved through macroscopically deforming the underlying substrate. For a bilayer system with traditional thermostable substrates, the pattern morphology is only determined by initial strain mismatch of the two layers, and the realization of localized patterns appears to be particularly challenging because of the difficulties associated with manipulating inhomogeneous deformations. In this work, we exploit cross-linked polyethylene ( cPE), a shape memory polymer (SMP), as the flexible substrate for building micro-/nano-structures of sputtered gold films. We find that the shape memory effect can offer new dimensions for designing diverse and hierarchical surface structures by harnessing film thickness orheating time and by globally or locally controlling the thermal field. By combining those strategies, we further demonstrate versatile hierarchical, superimposed, and local surface patterns based on this cPE/gold (Au) system. Piezoresistive pressure sensors are assembled with the obtained patterned surface, which have high sensitivity, operational range, and cyclic stability. These results highlight the unique advantages of SMPs for building arbitrary surface patterns.
Collapse
Affiliation(s)
- Lingyu Zhao
- CAS Key Laboratory of Nanosystem and Hierarchical Fabrication and CAS Center for Excellence in Nanoscience , National Center for Nanoscience and Technology , Beijing 100190 , China
- Academy for Advanced Interdisciplinary Studies , Peking University , Beijing 100871 , China
- University of Chinese Academy of Sciences , Beijing 100049 , China
| | - Liangpei Zhang
- CAS Key Laboratory of Nanosystem and Hierarchical Fabrication and CAS Center for Excellence in Nanoscience , National Center for Nanoscience and Technology , Beijing 100190 , China
- School of Materials Science and Technology , China University of Geosciences (Beijing) , Beijing 100083 , China
| | - Jun Zhao
- CAS Key Laboratory of Nanosystem and Hierarchical Fabrication and CAS Center for Excellence in Nanoscience , National Center for Nanoscience and Technology , Beijing 100190 , China
- University of Chinese Academy of Sciences , Beijing 100049 , China
| | - Jidong Shi
- CAS Key Laboratory of Nanosystem and Hierarchical Fabrication and CAS Center for Excellence in Nanoscience , National Center for Nanoscience and Technology , Beijing 100190 , China
- University of Chinese Academy of Sciences , Beijing 100049 , China
| | - Zhaohe Dai
- Center for Mechanics of Solids, Structures and Materials, Department of Aerospace Engineering and Engineering Mechanics , The University of Texas at Austin , Austin , Texas 78712 , United States
| | - Guorui Wang
- CAS Key Laboratory of Nanosystem and Hierarchical Fabrication and CAS Center for Excellence in Nanoscience , National Center for Nanoscience and Technology , Beijing 100190 , China
| | - Cheng Zhang
- Institute of Biomechanics and Medical Engineering, AML, Department of Engineering Mechanics , Tsinghua University , Beijing , 100084 , China
| | - Bo Li
- Institute of Biomechanics and Medical Engineering, AML, Department of Engineering Mechanics , Tsinghua University , Beijing , 100084 , China
| | - Xiqiao Feng
- Institute of Biomechanics and Medical Engineering, AML, Department of Engineering Mechanics , Tsinghua University , Beijing , 100084 , China
| | - Hui Zhang
- CAS Key Laboratory of Nanosystem and Hierarchical Fabrication and CAS Center for Excellence in Nanoscience , National Center for Nanoscience and Technology , Beijing 100190 , China
| | - Jin Zhang
- Academy for Advanced Interdisciplinary Studies , Peking University , Beijing 100871 , China
| | - Zhong Zhang
- CAS Key Laboratory of Nanosystem and Hierarchical Fabrication and CAS Center for Excellence in Nanoscience , National Center for Nanoscience and Technology , Beijing 100190 , China
- University of Chinese Academy of Sciences , Beijing 100049 , China
| |
Collapse
|
271
|
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation. Nat Biomed Eng 2019; 3:58-68. [DOI: 10.1038/s41551-018-0335-6] [Citation(s) in RCA: 299] [Impact Index Per Article: 49.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Accepted: 11/27/2018] [Indexed: 12/11/2022]
|
272
|
Jayant K, Wenzel M, Bando Y, Hamm JP, Mandriota N, Rabinowitz JH, Plante IJL, Owen JS, Sahin O, Shepard KL, Yuste R. Flexible Nanopipettes for Minimally Invasive Intracellular Electrophysiology In Vivo. Cell Rep 2019; 26:266-278.e5. [PMID: 30605681 PMCID: PMC7263204 DOI: 10.1016/j.celrep.2018.12.019] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 10/23/2018] [Accepted: 12/04/2018] [Indexed: 12/01/2022] Open
Abstract
Intracellular recordings in vivo remains the best technique to link single-neuron electrical properties to network function. Yet existing methods are limited in accuracy, throughput, and duration, primarily via washout, membrane damage, and movement-induced failure. Here, we introduce flexible quartz nanopipettes (inner diameters of 10-25 nm and spring constant of ∼0.08 N/m) as nanoscale analogs of traditional glass microelectrodes. Nanopipettes enable stable intracellular recordings (seal resistances of 500 to ∼800 MΩ, 5 to ∼10 cells/nanopipette, and duration of ∼1 hr) in anaesthetized and awake head-restrained mice, exhibit minimal diffusional flux, and facilitate precise recording and stimulation. When combined with quantum-dot labels and microprisms, nanopipettes enable two-photon targeted electrophysiology from both somata and dendrites, and even paired recordings from neighboring neurons, while permitting simultaneous population imaging across cortical layers. We demonstrate the versatility of this method by recording from parvalbumin-positive (Pv) interneurons while imaging seizure propagation, and we find that Pv depolarization block coincides with epileptic spread. Flexible nanopipettes present a simple method to procure stable intracellular recordings in vivo.
Collapse
Affiliation(s)
- Krishna Jayant
- Department of Electrical Engineering, Columbia University, New York, NY 10027, USA; Department of Biological Sciences, Columbia University, New York, NY 10027, USA; NeuroTechnology Center, Columbia University, New York, NY 10027, USA; Kavli Institute for Brain Science, Columbia University, New York, NY 10027, USA.
| | - Michael Wenzel
- Department of Biological Sciences, Columbia University, New York, NY 10027, USA; NeuroTechnology Center, Columbia University, New York, NY 10027, USA; Kavli Institute for Brain Science, Columbia University, New York, NY 10027, USA
| | - Yuki Bando
- Department of Biological Sciences, Columbia University, New York, NY 10027, USA; NeuroTechnology Center, Columbia University, New York, NY 10027, USA; Kavli Institute for Brain Science, Columbia University, New York, NY 10027, USA
| | - Jordan P Hamm
- Department of Biological Sciences, Columbia University, New York, NY 10027, USA; NeuroTechnology Center, Columbia University, New York, NY 10027, USA; Kavli Institute for Brain Science, Columbia University, New York, NY 10027, USA
| | - Nicola Mandriota
- Department of Biological Sciences, Columbia University, New York, NY 10027, USA
| | - Jake H Rabinowitz
- Department of Electrical Engineering, Columbia University, New York, NY 10027, USA
| | - Ilan Jen-La Plante
- Department of Chemistry, Columbia University, New York, NY 10027, USA; NeuroTechnology Center, Columbia University, New York, NY 10027, USA
| | - Jonathan S Owen
- Department of Chemistry, Columbia University, New York, NY 10027, USA; NeuroTechnology Center, Columbia University, New York, NY 10027, USA
| | - Ozgur Sahin
- Department of Biological Sciences, Columbia University, New York, NY 10027, USA; Department of Physics, Columbia University, New York, NY 10027, USA; NeuroTechnology Center, Columbia University, New York, NY 10027, USA
| | - Kenneth L Shepard
- Department of Electrical Engineering, Columbia University, New York, NY 10027, USA; Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA; NeuroTechnology Center, Columbia University, New York, NY 10027, USA; Kavli Institute for Brain Science, Columbia University, New York, NY 10027, USA
| | - Rafael Yuste
- Department of Biological Sciences, Columbia University, New York, NY 10027, USA; NeuroTechnology Center, Columbia University, New York, NY 10027, USA; Kavli Institute for Brain Science, Columbia University, New York, NY 10027, USA
| |
Collapse
|
273
|
Robinson JT, Pohlmeyer E, Gather MC, Kemere C, Kitching JE, Malliaras GG, Marblestone A, Shepard KL, Stieglitz T, Xie C. Developing Next-generation Brain Sensing Technologies - A Review. IEEE SENSORS JOURNAL 2019; 19:10.1109/jsen.2019.2931159. [PMID: 32116472 PMCID: PMC7047830 DOI: 10.1109/jsen.2019.2931159] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Advances in sensing technology raise the possibility of creating neural interfaces that can more effectively restore or repair neural function and reveal fundamental properties of neural information processing. To realize the potential of these bioelectronic devices, it is necessary to understand the capabilities of emerging technologies and identify the best strategies to translate these technologies into products and therapies that will improve the lives of patients with neurological and other disorders. Here we discuss emerging technologies for sensing brain activity, anticipated challenges for translation, and perspectives for how to best transition these technologies from academic research labs to useful products for neuroscience researchers and human patients.
Collapse
Affiliation(s)
- Jacob T. Robinson
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, USA
- Department of Bioengineering, Rice University, Houston, TX 77005, USA
- Department of Neuroscience, Baylor College of Medicine, Houston, TX 77030, USA
| | - Eric Pohlmeyer
- John Hopkins University Applied Physics Laboratory, Laurel, MD 20723, USA
| | - Malte C. Gather
- SUPA, School of Physics & Astronomy, University of St Andrews, St Andrews KY16 9SS Scotland, UK
| | - Caleb Kemere
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, USA
- Department of Bioengineering, Rice University, Houston, TX 77005, USA
| | - John E. Kitching
- Time and Frequency Division, NIST, 325 Broadway, Boulder, Colorado 80305, USA
| | - George G. Malliaras
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, UK
| | - Adam Marblestone
- MIT Media Lab, Massachusetts Institute of Technology (MIT), Cambridge, MA 02139, USA
| | - Kenneth L. Shepard
- Department of Electrical Engineering, Columbia University, New York, NY 10027, USA
| | - Thomas Stieglitz
- Institute of Microsystem Technology, Laboratory for Biomedical Microtechnology, D-79110 Freiburg, Germany
- Cluster of Excellence BrainLinks-BrainTools, University of Freiburg, 79110 Freiburg, Germany
- Bernstein Center Freiburg, University of Freiburg, 79104 Freiburg, Germany
| | - Chong Xie
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
| |
Collapse
|
274
|
Choi JR, Kim SM, Ryu RH, Kim SP, Sohn JW. Implantable Neural Probes for Brain-Machine Interfaces - Current Developments and Future Prospects. Exp Neurobiol 2018; 27:453-471. [PMID: 30636899 PMCID: PMC6318554 DOI: 10.5607/en.2018.27.6.453] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Revised: 11/15/2018] [Accepted: 11/15/2018] [Indexed: 12/14/2022] Open
Abstract
A Brain-Machine interface (BMI) allows for direct communication between the brain and machines. Neural probes for recording neural signals are among the essential components of a BMI system. In this report, we review research regarding implantable neural probes and their applications to BMIs. We first discuss conventional neural probes such as the tetrode, Utah array, Michigan probe, and electroencephalography (ECoG), following which we cover advancements in next-generation neural probes. These next-generation probes are associated with improvements in electrical properties, mechanical durability, biocompatibility, and offer a high degree of freedom in practical settings. Specifically, we focus on three key topics: (1) novel implantable neural probes that decrease the level of invasiveness without sacrificing performance, (2) multi-modal neural probes that measure both electrical and optical signals, (3) and neural probes developed using advanced materials. Because safety and precision are critical for practical applications of BMI systems, future studies should aim to enhance these properties when developing next-generation neural probes.
Collapse
Affiliation(s)
- Jong-Ryul Choi
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation (DGMIF), Daegu 41061, Korea
| | - Seong-Min Kim
- Department of Medical Science, College of Medicine, Catholic Kwandong University, Gangneung 25601, Korea.,Biomedical Research Institute, Catholic Kwandong University International St. Mary's Hospital, Incheon 21711, Korea
| | - Rae-Hyung Ryu
- Laboratory Animal Center, Daegu-Gyeongbuk Medical Innovation Foundation (DGMIF), Daegu 41061, Korea
| | - Sung-Phil Kim
- Department of Human Factors Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea
| | - Jeong-Woo Sohn
- Department of Medical Science, College of Medicine, Catholic Kwandong University, Gangneung 25601, Korea.,Biomedical Research Institute, Catholic Kwandong University International St. Mary's Hospital, Incheon 21711, Korea
| |
Collapse
|
275
|
Ambhorkar P, Wang Z, Ko H, Lee S, Koo KI, Kim K, Cho DID. Nanowire-Based Biosensors: From Growth to Applications. MICROMACHINES 2018; 9:mi9120679. [PMID: 30572645 PMCID: PMC6316191 DOI: 10.3390/mi9120679] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 12/15/2018] [Accepted: 12/17/2018] [Indexed: 01/02/2023]
Abstract
Over the past decade, synthesized nanomaterials, such as carbon nanotube, nanoparticle, quantum dot, and nanowire, have already made breakthroughs in various fields, including biomedical sensors. Enormous surface area-to-volume ratio of the nanomaterials increases sensitivity dramatically compared with macro-sized material. Herein we present a comprehensive review about the working principle and fabrication process of nanowire sensor. Moreover, its applications for the detection of biomarker, virus, and DNA, as well as for drug discovery, are reviewed. Recent advances including self-powering, reusability, sensitivity in high ionic strength solvent, and long-term stability are surveyed and highlighted as well. Nanowire is expected to lead significant improvement of biomedical sensor in the near future.
Collapse
Affiliation(s)
- Pranav Ambhorkar
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada.
| | - Zongjie Wang
- Department of Electrical and Computer Engineering, Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M5S 3M2, Canada.
| | - Hyuongho Ko
- Department of Electronics, Chungnam National University, Daejeon 34134, Korea.
| | - Sangmin Lee
- Department of Biomedical Engineering, Kyung Hee University, Yongin 17104, Korea.
| | - Kyo-In Koo
- Department of Biomedical Engineering, University of Ulsan, Ulsan 44610, Korea.
| | - Keekyoung Kim
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada.
| | - Dong-Il Dan Cho
- ASRI/ISRC, Department of Electrical and Computer Engineering, Seoul National University, Seoul 08826, Korea.
| |
Collapse
|
276
|
Kokubo N, Arake M, Yamagishi K, Morimoto Y, Takeoka S, Ohta H, Fujie T. Inkjet-Printed Neural Electrodes with Mechanically Gradient Structure. ACS APPLIED BIO MATERIALS 2018; 2:20-26. [DOI: 10.1021/acsabm.8b00574] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
| | | | | | | | | | | | - Toshinori Fujie
- PRESTO, Japan Science and Technology Agency, 4-1-8, Honcho, Kawaguchi-shi, Saitama 332-0012, Japan
- School of Life Science and Technology, Tokyo Institute of Technology, B-50, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8501, Japan
| |
Collapse
|
277
|
Abstract
Biological systems respond to and communicate through biophysical cues, such as electrical, thermal, mechanical and topographical signals. However, precise tools for introducing localized physical stimuli and/or for sensing biological responses to biophysical signals with high spatiotemporal resolution are limited. Inorganic semiconductors display many relevant electrical and optical properties, and they can be fabricated into a broad spectrum of electronic and photonic devices. Inorganic semiconductor devices enable the formation of functional interfaces with biological material, ranging from proteins to whole organs. In this Review, we discuss fundamental semiconductor physics and operation principles, with a focus on their behaviour in physiological conditions, and highlight the advantages of inorganic semiconductors for the establishment of biointerfaces. We examine semiconductor device design and synthesis and discuss typical signal transduction mechanisms at bioelectronic and biophotonic interfaces for electronic and optoelectronic sensing, optoelectronic and photothermal stimulation and photoluminescent in vivo imaging of cells and tissues. Finally, we evaluate cytotoxicity and highlight possible new material components and biological targets of inorganic semiconductor devices.
Collapse
|
278
|
Luchkina NV, Bolshakov VY. Diminishing fear: Optogenetic approach toward understanding neural circuits of fear control. Pharmacol Biochem Behav 2018; 174:64-79. [PMID: 28502746 PMCID: PMC5681900 DOI: 10.1016/j.pbb.2017.05.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Revised: 04/13/2017] [Accepted: 05/10/2017] [Indexed: 02/05/2023]
Abstract
Understanding complex behavioral processes, both learned and innate, requires detailed characterization of the principles governing signal flow in corresponding neural circuits. Previous studies were hampered by the lack of appropriate tools needed to address the complexities of behavior-driving micro- and macrocircuits. The development and implementation of optogenetic methodologies revolutionized the field of behavioral neuroscience, allowing precise spatiotemporal control of specific, genetically defined neuronal populations and their functional connectivity both in vivo and ex vivo, thus providing unprecedented insights into the cellular and network-level mechanisms contributing to behavior. Here, we review recent pioneering advances in behavioral studies with optogenetic tools, focusing on mechanisms of fear-related behavioral processes with an emphasis on approaches which could be used to suppress fear when it is pathologically expressed. We also discuss limitations of these methodologies as well as review new technological developments which could be used in future mechanistic studies of fear behavior.
Collapse
Affiliation(s)
- Natalia V Luchkina
- Department of Psychiatry, McLean Hospital, Harvard Medical School, Belmont, MA 02478, USA.
| | - Vadim Y Bolshakov
- Department of Psychiatry, McLean Hospital, Harvard Medical School, Belmont, MA 02478, USA.
| |
Collapse
|
279
|
Liu Z, Zhou Z, Zhang S, Sun L, Shi Z, Mao Y, Liu K, Tao TH. "Print-to-pattern": Silk-Based Water Lithography. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2018; 14:e1802953. [PMID: 30277661 DOI: 10.1002/smll.201802953] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Revised: 08/02/2018] [Indexed: 06/08/2023]
Abstract
The requirement of nontoxic and versatile manufacturing frameworks for biologically relevant applications has imposed significant constraints on the choice of functional materials and the complementary fabrication tools. In this context, silk is actively studied, thanks to its mechanical robustness, biocompatibility, wide availability, aqueous processing conditions, and ease of functionalization. The inherent matching between the water solubility of silk and the aqueous inks of the inkjet printing (IJP) process has derived a biofriendly and versatile "print-to-pattern" scheme-termed silk-based water lithography-toward scalable functional biomanufacturing. The deposition mode of IJP and the etching effect of silk film by water features a dual tone fabrication where functional molecules are dispensed additively, while the silk film is patterned in a "subtractive" fashion. Such versatility and scalability pave the way to a wide range of opportunities in the biomedical field.
Collapse
Affiliation(s)
- Zhen Liu
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China
- The Key Laboratory of Resource Chemistry of Ministry of Education, Shanghai Normal University, Shanghai, 200234, China
| | - Zhitao Zhou
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China
- School of Graduate Study, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Shaoqing Zhang
- Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA
| | - Long Sun
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China
- School of Graduate Study, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Zhifeng Shi
- Department of Neurosurgery, Huashan Hospital of Fudan University, Wulumuqi Zhong Road 12, Shanghai, 200040, China
| | - Ying Mao
- Department of Neurosurgery, Huashan Hospital of Fudan University, Wulumuqi Zhong Road 12, Shanghai, 200040, China
| | - Keyin Liu
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Tiger H Tao
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China
- School of Graduate Study, University of Chinese Academy of Sciences, Beijing, 100049, China
- School of Physical Science and Technology, ShanghaiTech University, Shanghai, 200031, China
| |
Collapse
|
280
|
Soft conductive micropillar electrode arrays for biologically relevant electrophysiological recording. Proc Natl Acad Sci U S A 2018; 115:11718-11723. [PMID: 30377271 DOI: 10.1073/pnas.1810827115] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Multielectrode arrays (MEAs) are essential tools in neural and cardiac research as they provide a means for noninvasive, multiplexed recording of extracellular field potentials with high temporal resolution. To date, the mechanical properties of the electrode material, e.g., its Young's modulus, have not been taken into consideration in most MEA designs leaving hard materials as the default choice due to their established fabrication processes. However, the cell-electrode interface is known to significantly affect some aspects of the cell's behavior. In this paper, we describe the fabrication of a soft 3D micropillar electrode array. Using this array, we proceed to successfully record action potentials from monolayer cell cultures. Specifically, our conductive hydrogel micropillar electrode showed improved signal amplitude and signal-to-noise ratio, compared with conventional hard iridium oxide micropillar electrodes of the same diameter. Taken together, our fabricated soft micropillar electrode array will provide a tissue-like Young's modulus and thus a relevant mechanical microenvironment to fundamental cardiac and neural studies.
Collapse
|
281
|
Shimada T, Yasui T, Yokoyama A, Goda T, Hara M, Yanagida T, Kaji N, Kanai M, Nagashima K, Miyahara Y, Kawai T, Baba Y. Biomolecular recognition on nanowire surfaces modified by the self-assembled monolayer. LAB ON A CHIP 2018; 18:3225-3229. [PMID: 30264843 DOI: 10.1039/c8lc00438b] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Molecular recognition is one of the key factors in designing biosensors due to which nanowires functionalized with molecular recognition have attracted a lot of attention as promising candidates for nanostructures embedded in biosensors. However, the difficulty in real-world applications with analytical specificity is that molecular recognition on nanowires mainly depends on antibody modification with multistep modification procedures. Furthermore, the antibody modification suffers from nonspecific adsorption of undesired proteins in body fluid on the nanowires, which causes false responses and lowers sensitivity. Herein, we propose biomolecular recognition using surface-modified nanowires via thiolated 2-methacryloxyethyl phosphorylcholine (MPC-SH). MPC-SH enables self-assembled monolayer (SAM) modification, which contributes to the reduction of nonspecific adsorption of biomolecules onto the nanowires, and the specific capture of a target protein is attained in the presence of calcium ions. Our concept demonstrates the recognition of the biomarker protein on nanowire surfaces modified by MPC-SH SAM with a single step modification procedure.
Collapse
Affiliation(s)
- Taisuke Shimada
- Department of Biomolecular Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
282
|
Yang J, Du M, Wang L, Li S, Wang G, Yang X, Zhang L, Fang Y, Zheng W, Yang G, Jiang X. Bacterial Cellulose as a Supersoft Neural Interfacing Substrate. ACS APPLIED MATERIALS & INTERFACES 2018; 10:33049-33059. [PMID: 30208275 DOI: 10.1021/acsami.8b12083] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Biocompatible neural interfaces hold great promise for treating neurological disorders and enhancing the mental and physical ability of human beings. Most of the currently available neural interfaces are made from rigid, dense inorganic materials that cause tissue damage. We present supersoft multichannel electrodes by depositing gold layers on thin bacterial cellulose (BC) (Au-BC electrodes). The Young's modulus of BC ( EBC = 120 kPa) is between those of the brain tissue ( Ebrain = 2.7-3.1 kPa) and the peripheral neural tissues ( Eperipheral nerve = 580-840 kPa). The bending stiffness of the Au-BC electrodes corresponds to 1/5200 of Au-polyimide electrodes with the same layout. Furthermore, the Au-BC electrodes are highly durable (conductivity >95% after 100 cycles of 180° bending). In vivo recording of brain electric activity demonstrates the great potential of the Au-BC electrodes for neural interfacing applications.
Collapse
Affiliation(s)
- Junchuan Yang
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center of Excellence for Nanoscience , National Center for NanoScience and Technology , Beijing , 100190 , China
- National Engineering Research Center for Nano-Medicine, Department of Biomedical Engineering, College of Life Science and Technology , Huazhong University of Science and Technology , Wuhan , 430074 , China
| | - Mingde Du
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center of Excellence for Nanoscience , National Center for NanoScience and Technology , Beijing , 100190 , China
- University of Chinese Academy of Sciences , Beijing , 100049 , China
| | - Le Wang
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center of Excellence for Nanoscience , National Center for NanoScience and Technology , Beijing , 100190 , China
| | - Sixiang Li
- National Engineering Research Center for Nano-Medicine, Department of Biomedical Engineering, College of Life Science and Technology , Huazhong University of Science and Technology , Wuhan , 430074 , China
| | - Guorui Wang
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center of Excellence for Nanoscience , National Center for NanoScience and Technology , Beijing , 100190 , China
| | - Xinglong Yang
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center of Excellence for Nanoscience , National Center for NanoScience and Technology , Beijing , 100190 , China
- University of Chinese Academy of Sciences , Beijing , 100049 , China
| | - Lijuan Zhang
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center of Excellence for Nanoscience , National Center for NanoScience and Technology , Beijing , 100190 , China
| | - Ying Fang
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center of Excellence for Nanoscience , National Center for NanoScience and Technology , Beijing , 100190 , China
| | - Wenfu Zheng
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center of Excellence for Nanoscience , National Center for NanoScience and Technology , Beijing , 100190 , China
| | - Guang Yang
- National Engineering Research Center for Nano-Medicine, Department of Biomedical Engineering, College of Life Science and Technology , Huazhong University of Science and Technology , Wuhan , 430074 , China
| | - Xingyu Jiang
- Beijing Engineering Research Center for BioNanotechnology, CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center of Excellence for Nanoscience , National Center for NanoScience and Technology , Beijing , 100190 , China
- University of Chinese Academy of Sciences , Beijing , 100049 , China
| |
Collapse
|
283
|
Lee W, Kobayashi S, Nagase M, Jimbo Y, Saito I, Inoue Y, Yambe T, Sekino M, Malliaras GG, Yokota T, Tanaka M, Someya T. Nonthrombogenic, stretchable, active multielectrode array for electroanatomical mapping. SCIENCE ADVANCES 2018; 4:eaau2426. [PMID: 30345362 PMCID: PMC6195340 DOI: 10.1126/sciadv.aau2426] [Citation(s) in RCA: 109] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Accepted: 09/12/2018] [Indexed: 05/19/2023]
Abstract
High-precision monitoring of electrophysiological signals with high spatial and temporal resolutions is one of the most important subjects for elucidating physiology functions. Recently, ultraflexible multielectrode arrays (MEAs) have been fabricated to establish conformal contacts with the surface of organs and to measure propagation of electrophysiological signals with high spatial-temporal resolution; however, plastic substrates have high Young's modulus, causing difficulties in creating appropriate stretchability and blood compatibility for applying them on the dynamically moving and surgical bleeding surface of the heart. Here, we have successfully fabricated an active MEA that simultaneously achieves nonthrombogenicity, stretchability, and stability, which allows long-term electrocardiographic (ECG) monitoring of the dynamically moving hearts of rats even with capillary bleeding. Because of the active data readout, the measured ECG signals exhibit a high signal-to-noise ratio of 52 dB. The novel stretchable MEA is carefully designed using state-of-the-art engineering techniques by combining extraordinarily high gain organic electrochemical transistors processed on microgrid substrates and a coating of poly(3-methoxypropyl acrylate), which exhibits significant antithrombotic properties while maintaining excellent ionic conductivity.
Collapse
Affiliation(s)
- Wonryung Lee
- Department of Electrical Engineering and Information Systems, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Shingo Kobayashi
- Institute for Materials Chemistry and Engineering, Kyushu University, CE41 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Masase Nagase
- Department of Electrical Engineering and Information Systems, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
- iMed Japan Inc., 6-11-24, Higashi-Narashino, Narashino-shi, Chiba 275-0001, Japan
| | - Yasutoshi Jimbo
- Department of Electrical Engineering and Information Systems, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Itsuro Saito
- Department of Electrical Engineering and Information Systems, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
- iMed Japan Inc., 6-11-24, Higashi-Narashino, Narashino-shi, Chiba 275-0001, Japan
| | - Yusuke Inoue
- Department of Medical Engineering and Cardiology, Institute of Development Aging and Cancer, Tohoku University, Miyagi, Japan
| | - Tomoyuki Yambe
- Department of Medical Engineering and Cardiology, Institute of Development Aging and Cancer, Tohoku University, Miyagi, Japan
| | - Masaki Sekino
- Department of Electrical Engineering and Information Systems, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | | | - Tomoyuki Yokota
- Department of Electrical Engineering and Information Systems, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Masaru Tanaka
- Institute for Materials Chemistry and Engineering, Kyushu University, CE41 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Takao Someya
- Department of Electrical Engineering and Information Systems, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
- Thin-Film Device Laboratory & Center for Emergent Matter Science (CEMS), RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan
| |
Collapse
|
284
|
Mehrali M, Bagherifard S, Akbari M, Thakur A, Mirani B, Mehrali M, Hasany M, Orive G, Das P, Emneus J, Andresen TL, Dolatshahi‐Pirouz A. Blending Electronics with the Human Body: A Pathway toward a Cybernetic Future. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2018; 5:1700931. [PMID: 30356969 PMCID: PMC6193179 DOI: 10.1002/advs.201700931] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Revised: 05/24/2018] [Indexed: 05/22/2023]
Abstract
At the crossroads of chemistry, electronics, mechanical engineering, polymer science, biology, tissue engineering, computer science, and materials science, electrical devices are currently being engineered that blend directly within organs and tissues. These sophisticated devices are mediators, recorders, and stimulators of electricity with the capacity to monitor important electrophysiological events, replace disabled body parts, or even stimulate tissues to overcome their current limitations. They are therefore capable of leading humanity forward into the age of cyborgs, a time in which human biology can be hacked at will to yield beings with abilities beyond their natural capabilities. The resulting advances have been made possible by the emergence of conformal and soft electronic materials that can readily integrate with the curvilinear, dynamic, delicate, and flexible human body. This article discusses the recent rapid pace of development in the field of cybernetics with special emphasis on the important role that flexible and electrically active materials have played therein.
Collapse
Affiliation(s)
- Mehdi Mehrali
- Technical University of DenmarkDTU NanotechCenter for Nanomedicine and Theranostics2800KgsDenmark
| | - Sara Bagherifard
- Department of Mechanical EngineeringPolitecnico di Milano20156MilanItaly
| | - Mohsen Akbari
- Laboratory for Innovations in MicroEngineering (LiME)Department of Mechanical EngineeringUniversity of VictoriaVictoriaBCV8P 5C2Canada
- Center for Biomedical ResearchUniversity of VictoriaVictoriaV8P 5C2Canada
- Center for Advanced Materials and Related Technologies (CAMTEC)University of VictoriaVictoriaV8P 5C2Canada
| | - Ashish Thakur
- Technical University of DenmarkDTU NanotechCenter for Nanomedicine and Theranostics2800KgsDenmark
| | - Bahram Mirani
- Laboratory for Innovations in MicroEngineering (LiME)Department of Mechanical EngineeringUniversity of VictoriaVictoriaBCV8P 5C2Canada
- Center for Biomedical ResearchUniversity of VictoriaVictoriaV8P 5C2Canada
- Center for Advanced Materials and Related Technologies (CAMTEC)University of VictoriaVictoriaV8P 5C2Canada
| | - Mohammad Mehrali
- Process and Energy DepartmentDelft University of TechnologyLeeghwaterstraat 392628CBDelftThe Netherlands
| | - Masoud Hasany
- Technical University of DenmarkDTU NanotechCenter for Nanomedicine and Theranostics2800KgsDenmark
| | - Gorka Orive
- NanoBioCel GroupLaboratory of PharmaceuticsSchool of PharmacyUniversity of the Basque Country UPV/EHUPaseo de la Universidad 701006Vitoria‐GasteizSpain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials, and Nanomedicine (CIBER‐BBN)Vitoria‐Gasteiz28029Spain
- University Institute for Regenerative Medicine and Oral Implantology—UIRMI (UPV/EHU‐Fundación Eduardo Anitua)Vitoria01007Spain
| | - Paramita Das
- School of Chemical and Biomedical EngineeringNanyang Technological University62 Nanyang DriveSingapore637459Singapore
| | - Jenny Emneus
- Technical University of DenmarkDTU Nanotech2800KgsDenmark
| | - Thomas L. Andresen
- Technical University of DenmarkDTU NanotechCenter for Nanomedicine and Theranostics2800KgsDenmark
| | | |
Collapse
|
285
|
Shoffstall AJ, Ecker M, Danda V, Joshi-Imre A, Stiller A, Yu M, Paiz JE, Mancuso E, Bedell HW, Voit WE, Pancrazio JJ, Capadona JR. Characterization of the Neuroinflammatory Response to Thiol-ene Shape Memory Polymer Coated Intracortical Microelectrodes. MICROMACHINES 2018; 9:E486. [PMID: 30424419 PMCID: PMC6215215 DOI: 10.3390/mi9100486] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 09/11/2018] [Accepted: 09/18/2018] [Indexed: 01/10/2023]
Abstract
Thiol-ene based shape memory polymers (SMPs) have been developed for use as intracortical microelectrode substrates. The unique chemistry provides precise control over the mechanical and thermal glass-transition properties. As a result, SMP substrates are stiff at room temperature, allowing for insertion into the brain without buckling and subsequently soften in response to body temperatures, reducing the mechanical mismatch between device and tissue. Since the surface chemistry of the materials can contribute significantly to the ultimate biocompatibility, as a first step in the characterization of our SMPs, we sought to isolate the biological response to the implanted material surface without regards to the softening mechanics. To accomplish this, we tightly controlled for bulk stiffness by comparing bare silicon 'dummy' devices to thickness-matched silicon devices dip-coated with SMP. The neuroinflammatory response was evaluated after devices were implanted in the rat cortex for 2 or 16 weeks. We observed no differences in the markers tested at either time point, except that astrocytic scarring was significantly reduced for the dip-coated implants at 16 weeks. The surface properties of non-softening thiol-ene SMP substrates appeared to be equally-tolerated and just as suitable as silicon for neural implant substrates for applications such as intracortical microelectrodes, laying the groundwork for future softer devices to improve upon the prototype device performance presented here.
Collapse
Affiliation(s)
- Andrew J Shoffstall
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
- Advanced Platform Technology Center, Rehabilitation Research and Development, Louis Stokes Cleveland Department of Veteran Affairs Medical Center, Cleveland, OH, USA.
| | - Melanie Ecker
- Advanced Platform Technology Center, Rehabilitation Research and Development, Louis Stokes Cleveland Department of Veteran Affairs Medical Center, Cleveland, OH, USA.
- Department of Materials Science and Engineering, The University of Texas at Dallas, Richardson, TX, USA.
| | - Vindhya Danda
- Department of Materials Science and Engineering, The University of Texas at Dallas, Richardson, TX, USA.
- Center for Engineering Innovation, The University of Texas at Dallas, Richardson, TX, USA.
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, USA.
- Department of Mechanical Engineering, The University of Texas at Dallas, Richardson, TX, USA.
| | - Alexandra Joshi-Imre
- Center for Engineering Innovation, The University of Texas at Dallas, Richardson, TX, USA.
| | - Allison Stiller
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, USA.
| | - Marina Yu
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
- Advanced Platform Technology Center, Rehabilitation Research and Development, Louis Stokes Cleveland Department of Veteran Affairs Medical Center, Cleveland, OH, USA.
| | - Jennifer E Paiz
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
- Advanced Platform Technology Center, Rehabilitation Research and Development, Louis Stokes Cleveland Department of Veteran Affairs Medical Center, Cleveland, OH, USA.
| | - Elizabeth Mancuso
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
- Advanced Platform Technology Center, Rehabilitation Research and Development, Louis Stokes Cleveland Department of Veteran Affairs Medical Center, Cleveland, OH, USA.
| | - Hillary W Bedell
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
| | - Walter E Voit
- Department of Materials Science and Engineering, The University of Texas at Dallas, Richardson, TX, USA.
- Center for Engineering Innovation, The University of Texas at Dallas, Richardson, TX, USA.
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, USA.
- Department of Mechanical Engineering, The University of Texas at Dallas, Richardson, TX, USA.
| | - Joseph J Pancrazio
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, USA.
| | - Jeffrey R Capadona
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
- Advanced Platform Technology Center, Rehabilitation Research and Development, Louis Stokes Cleveland Department of Veteran Affairs Medical Center, Cleveland, OH, USA.
| |
Collapse
|
286
|
Schwerdt HN, Zhang E, Kim MJ, Yoshida T, Stanwicks L, Amemori S, Dagdeviren HE, Langer R, Cima MJ, Graybiel AM. Cellular-scale probes enable stable chronic subsecond monitoring of dopamine neurochemicals in a rodent model. Commun Biol 2018; 1:144. [PMID: 30272020 PMCID: PMC6135761 DOI: 10.1038/s42003-018-0147-y] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Accepted: 08/13/2018] [Indexed: 02/07/2023] Open
Abstract
Chemical signaling underlies both temporally phasic and extended activity in the brain. Phasic activity can be monitored by implanted sensors, but chronic recording of such chemical signals has been difficult because the capacity to measure them degrades over time. This degradation has been attributed to tissue damage progressively produced by the sensors and failure of the sensors themselves. We report methods that surmount these problems through the development of sensors having diameters as small as individual neuronal cell bodies (<10 µm). These micro-invasive probes (µIPs) markedly reduced expression of detectable markers of inflammation and tissue damage in a rodent test model. The chronically implanted µIPs provided stable operation in monitoring sub-second fluctuations in stimulation-evoked dopamine in anesthetized rats for over a year. These findings demonstrate that monitoring of chemical activity patterns in the brain over at least year-long periods, long a goal of both basic and clinical neuroscience, is achievable. Helen Schwerdt et al. report micro-invasive probes capable of monitoring chemical signaling in the rat brain for over a year. The probes have diameters as small as single neuronal cell bodies and can monitor sub-second fluctuations in chemical signaling without significant induction of inflammation or tissue damage.
Collapse
Affiliation(s)
- Helen N Schwerdt
- McGovern Institute for Brain Research and Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA. .,Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA.
| | - Elizabeth Zhang
- McGovern Institute for Brain Research and Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA.,Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Min Jung Kim
- McGovern Institute for Brain Research and Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Tomoko Yoshida
- McGovern Institute for Brain Research and Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Lauren Stanwicks
- McGovern Institute for Brain Research and Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Satoko Amemori
- McGovern Institute for Brain Research and Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Huseyin E Dagdeviren
- McGovern Institute for Brain Research and Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Robert Langer
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA.,Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Michael J Cima
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA. .,Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA.
| | - Ann M Graybiel
- McGovern Institute for Brain Research and Department of Brain and Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA.
| |
Collapse
|
287
|
Pas J, Rutz AL, Quilichini PP, Slézia A, Ghestem A, Kaszas A, Donahue MJ, Curto VF, O’Connor RP, Bernard C, Williamson A, Malliaras GG. A bilayered PVA/PLGA-bioresorbable shuttle to improve the implantation of flexible neural probes. J Neural Eng 2018; 15:065001. [DOI: 10.1088/1741-2552/aadc1d] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
288
|
Liu H, Li M, Ouyang C, Lu TJ, Li F, Xu F. Biofriendly, Stretchable, and Reusable Hydrogel Electronics as Wearable Force Sensors. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2018; 14:e1801711. [PMID: 30062710 DOI: 10.1002/smll.201801711] [Citation(s) in RCA: 75] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Revised: 06/12/2018] [Indexed: 06/08/2023]
Abstract
The ever-growing overlap between stretchable electronic devices and wearable healthcare applications is igniting the discovery of novel biocompatible and skin-like materials for human-friendly stretchable electronics fabrication. Amongst all potential candidates, hydrogels with excellent biocompatibility and mechanical features close to human tissues are constituting a promising troop for realizing healthcare-oriented electronic functionalities. In this work, based on biocompatible and stretchable hydrogels, a simple paradigm to prototype stretchable electronics with an embedded three-dimensional (3D) helical conductive layout is proposed. Thanks to the 3D helical structure, the hydrogel electronics present satisfactory mechanical and electrical robustness under stretch. In addition, reusability of stretchable electronics is realized with the proposed scenario benefiting from the swelling property of hydrogel. Although losing water would induce structure shrinkage of the hydrogel network and further undermine the function of hydrogel in various applications, the worn-out hydrogel electronics can be reused by simply casting it in water. Through such a rehydration procedure, the dehydrated hydrogel can absorb water from the surrounding and then the hydrogel electronics can achieve resilience in mechanical stretchability and electronic functionality. Also, the ability to reflect pressure and strain changes has revealed the hydrogel electronics to be promising for advanced wearable sensing applications.
Collapse
Affiliation(s)
- Hao Liu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Moxiao Li
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- State Key Laboratory for Strength and Vibration of Mechanical Structures, Aerospace School, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Cheng Ouyang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Tian Jian Lu
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- MOE Key Laboratory for Multifunctional Materials and Structures, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- College of Aerospace Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, 210016, P. R. China
| | - Fei Li
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Feng Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| |
Collapse
|
289
|
Hong G, Fu TM, Qiao M, Viveros RD, Yang X, Zhou T, Lee JM, Park HG, Sanes JR, Lieber CM. A method for single-neuron chronic recording from the retina in awake mice. Science 2018; 360:1447-1451. [PMID: 29954976 DOI: 10.1126/science.aas9160] [Citation(s) in RCA: 101] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Accepted: 04/26/2018] [Indexed: 12/16/2022]
Abstract
The retina, which processes visual information and sends it to the brain, is an excellent model for studying neural circuitry. It has been probed extensively ex vivo but has been refractory to chronic in vivo electrophysiology. We report a nonsurgical method to achieve chronically stable in vivo recordings from single retinal ganglion cells (RGCs) in awake mice. We developed a noncoaxial intravitreal injection scheme in which injected mesh electronics unrolls inside the eye and conformally coats the highly curved retina without compromising normal eye functions. The method allows 16-channel recordings from multiple types of RGCs with stable responses to visual stimuli for at least 2 weeks, and reveals circadian rhythms in RGC responses over multiple day/night cycles.
Collapse
Affiliation(s)
- Guosong Hong
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
| | - Tian-Ming Fu
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
| | - Mu Qiao
- Center for Brain Science and Department of Molecular and Cellular Biology, Harvard University, Cambridge, MA, USA
| | - Robert D Viveros
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Xiao Yang
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
| | - Tao Zhou
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA
| | - Jung Min Lee
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA.,Department of Physics, Korea University, Seoul, Republic of Korea
| | - Hong-Gyu Park
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA.,Department of Physics, Korea University, Seoul, Republic of Korea
| | - Joshua R Sanes
- Center for Brain Science and Department of Molecular and Cellular Biology, Harvard University, Cambridge, MA, USA
| | - Charles M Lieber
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA, USA. .,John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| |
Collapse
|
290
|
Song K, Kim J, Cho S, Kim N, Jung D, Choo H, Lee J. Flexible-Device Injector with a Microflap Array for Subcutaneously Implanting Flexible Medical Electronics. Adv Healthc Mater 2018; 7:e1800419. [PMID: 29938924 DOI: 10.1002/adhm.201800419] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2018] [Revised: 05/30/2018] [Indexed: 11/09/2022]
Abstract
Implantable electronics in soft and flexible forms can reduce undesired outcomes such as irritations and chronic damages to surrounding biological tissues due to the improved mechanical compatibility with soft tissues. However, the same mechanical flexibility also makes it difficult to insert such implants through the skin because of reduced stiffness. In this paper, a flexible-device injector that enables the subcutaneous implantation of flexible medical electronics is reported. The injector consists of a customized blade at the tip and a microflap array which holds the flexible implant while the injector penetrates through soft tissues. The microflap array eliminates the need of additional materials such as adhesives that require an extended period to release a flexible medical electronic implant from an injector inside the skin. The mechanical properties of the injection system during the insertion process are experimentally characterized, and the injection of a flexible optical pulse sensor and electrocardiogram sensor is successfully demonstrated in vivo in live pig animal models to establish the practical feasibility of the concept.
Collapse
Affiliation(s)
- Kwangsun Song
- School of Mechanical Engineering; Gwangju Institute of Science and Technology (GIST); 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
- Research Institute for Solar and Sustainable Energies; Gwangju Institute of Science and Technology (GIST); 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
| | - Juho Kim
- School of Mechanical Engineering; Gwangju Institute of Science and Technology (GIST); 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
- Research Institute for Solar and Sustainable Energies; Gwangju Institute of Science and Technology (GIST); 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
| | - Sungbum Cho
- School of Mechanical Engineering; Gwangju Institute of Science and Technology (GIST); 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
| | - Namyun Kim
- School of Mechanical Engineering; Gwangju Institute of Science and Technology (GIST); 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
| | - Dongwuk Jung
- School of Mechanical Engineering; Gwangju Institute of Science and Technology (GIST); 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
- Research Institute for Solar and Sustainable Energies; Gwangju Institute of Science and Technology (GIST); 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
| | - Hyuck Choo
- Department of Medical Engineering; California Institute of Technology; Pasadena CA 91125 USA
- Department of Electrical Engineering; California Institute of Technology; Pasadena CA 91125 USA
| | - Jongho Lee
- School of Mechanical Engineering; Gwangju Institute of Science and Technology (GIST); 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
- Research Institute for Solar and Sustainable Energies; Gwangju Institute of Science and Technology (GIST); 123 Cheomdangwagi-ro, Buk-gu Gwangju 61005 Republic of Korea
| |
Collapse
|
291
|
Schuhmann TG, Zhou T, Hong G, Lee JM, Fu TM, Park HG, Lieber CM. Syringe-injectable Mesh Electronics for Stable Chronic Rodent Electrophysiology. J Vis Exp 2018:58003. [PMID: 30080192 PMCID: PMC6126522 DOI: 10.3791/58003] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Implantable brain electrophysiology probes are valuable tools in neuroscience due to their ability to record neural activity with high spatiotemporal resolution from shallow and deep brain regions. Their use has been hindered, however, by mechanical and structural mismatches between the probes and brain tissue that commonly lead to micromotion and gliosis with resulting signal instability in chronic recording experiments. In contrast, following the implantation of ultraflexible mesh electronics via syringe injection, the mesh probes form a seamless, gliosis-free interface with the surrounding brain tissue that enables stable tracking of individual neurons on at least a year timescale. This protocol details the key steps in a typical mouse neural recording experiment using syringe-injectable mesh electronics, including the fabrication of mesh electronics in a standard photolithography-based process possible at many universities, loading mesh electronics into standard capillary needles, stereotaxic injection in vivo, connection of the mesh input/output to standard instrumentation interfaces, restrained or freely moving recording sessions, and histological sectioning of brain tissue containing mesh electronics. Representative neural recordings and histology data are presented. Investigators familiar with this protocol will have the knowledge necessary to incorporate mesh electronics into their own experiments and take advantage of the unique opportunities afforded by long-term stable neural interfacing, such as studies of aging processes, brain development, and the pathogenesis of brain disease.
Collapse
Affiliation(s)
- Thomas G Schuhmann
- John A. Paulson School of Engineering and Applied Sciences, Harvard University
| | - Tao Zhou
- Department of Chemistry and Chemical Biology, Harvard University
| | - Guosong Hong
- Department of Chemistry and Chemical Biology, Harvard University
| | - Jung Min Lee
- Department of Chemistry and Chemical Biology, Harvard University; Department of Physics, Korea University
| | - Tian-Ming Fu
- Department of Chemistry and Chemical Biology, Harvard University
| | | | - Charles M Lieber
- John A. Paulson School of Engineering and Applied Sciences, Harvard University; Department of Chemistry and Chemical Biology, Harvard University;
| |
Collapse
|
292
|
Hong G, Viveros RD, Zwang TJ, Yang X, Lieber CM. Tissue-like Neural Probes for Understanding and Modulating the Brain. Biochemistry 2018; 57:3995-4004. [PMID: 29529359 PMCID: PMC6039269 DOI: 10.1021/acs.biochem.8b00122] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Electrophysiology tools have contributed substantially to understanding brain function, yet the capabilities of conventional electrophysiology probes have remained limited in key ways because of large structural and mechanical mismatches with respect to neural tissue. In this Perspective, we discuss how the general goal of probe design in biochemistry, that the probe or label have a minimal impact on the properties and function of the system being studied, can be realized by minimizing structural, mechanical, and topological differences between neural probes and brain tissue, thus leading to a new paradigm of tissue-like mesh electronics. The unique properties and capabilities of the tissue-like mesh electronics as well as future opportunities are summarized. First, we discuss the design of an ultraflexible and open mesh structure of electronics that is tissue-like and can be delivered in the brain via minimally invasive syringe injection like molecular and macromolecular pharmaceuticals. Second, we describe the unprecedented tissue healing without chronic immune response that leads to seamless three-dimensional integration with a natural distribution of neurons and other key cells through these tissue-like probes. These unique characteristics lead to unmatched stable long-term, multiplexed mapping and modulation of neural circuits at the single-neuron level on a year time scale. Last, we offer insights on several exciting future directions for the tissue-like electronics paradigm that capitalize on their unique properties to explore biochemical interactions and signaling in a "natural" brain environment.
Collapse
Affiliation(s)
- Guosong Hong
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, Massachusetts 02138, USA
| | - Robert D. Viveros
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138, USA
| | - Theodore J. Zwang
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, Massachusetts 02138, USA
| | - Xiao Yang
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, Massachusetts 02138, USA
| | - Charles M. Lieber
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, Massachusetts 02138, USA
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138, USA
| |
Collapse
|
293
|
Won SM, Song E, Zhao J, Li J, Rivnay J, Rogers JA. Recent Advances in Materials, Devices, and Systems for Neural Interfaces. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2018; 30:e1800534. [PMID: 29855089 DOI: 10.1002/adma.201800534] [Citation(s) in RCA: 92] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 02/28/2018] [Indexed: 06/08/2023]
Abstract
Technologies capable of establishing intimate, long-lived optical/electrical interfaces to neural systems will play critical roles in neuroscience research and in the development of nonpharmacological treatments for neurological disorders. The development of high-density interfaces to 3D populations of neurons across entire tissue systems in living animals, including human subjects, represents a grand challenge for the field, where advanced biocompatible materials and engineered structures for electrodes and light emitters will be essential. This review summarizes recent progress in these directions, with an emphasis on the most promising demonstrated concepts, materials, devices, and systems. The article begins with an overview of electrode materials with enhanced electrical and/or mechanical performance, in forms ranging from planar films, to micro/nanostructured surfaces, to 3D porous frameworks and soft composites. Subsequent sections highlight integration with active materials and components for multiplexed addressing, local amplification, wireless data transmission, and power harvesting, with multimodal operation in soft, shape-conformal systems. These advances establish the foundations for scalable architectures in optical/electrical neural interfaces of the future, where a blurring of the lines between biotic and abiotic systems will catalyze profound progress in neuroscience research and in human health/well-being.
Collapse
Affiliation(s)
- Sang Min Won
- Department of Electrical and Computer Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Urbana, IL, 61801, USA
| | - Enming Song
- Department of Materials Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Northwestern University, Evanston, IL, 60208, USA
| | - Jianing Zhao
- Department of Mechanical Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Urbana, IL, 61801, USA
| | - Jinghua Li
- Department of Materials Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana Champaign, Northwestern University, Evanston, IL, 60208, USA
| | - Jonathan Rivnay
- Department of Biomedical Engineering, Simpson Querrey Institute for Nanobiotechnology, Northwestern University, Evanston, IL, 60208, USA
| | - John A Rogers
- Center for Bio-Integrated Electronics, Department of Materials Science and Engineering, Biomedical Engineering, Chemistry, Mechanical Engineering, Electrical Engineering and Computer Science, and Neurological Surgery, Simpson Querrey Institute for Nano/biotechnology, McCormick School of Engineering and Feinberg School of Medicine, Northwestern University, Evanston, IL, 60208, USA
| |
Collapse
|
294
|
Jiang Y, Li X, Liu B, Yi J, Fang Y, Shi F, Gao X, Sudzilovsky E, Parameswaran R, Koehler K, Nair V, Yue J, Guo K, Fang Y, Tsai HM, Freyermuth G, Wong RCS, Kao CM, Chen CT, Nicholls AW, Wu X, Shepherd GMG, Tian B. Rational design of silicon structures for optically controlled multiscale biointerfaces. Nat Biomed Eng 2018; 2:508-521. [PMID: 30906646 PMCID: PMC6430241 DOI: 10.1038/s41551-018-0230-1] [Citation(s) in RCA: 147] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Accepted: 03/20/2018] [Indexed: 01/28/2023]
Abstract
Silicon-based materials have been widely used. However, remotely controlled and interconnect-free silicon configurations have been rarely explored, because of limited fundamental understanding of the complex physicochemical processes that occur at interfaces between silicon and biological materials. Here, we describe rational design principles, guided by biology, for establishing intracellular, intercellular and extracellular silicon-based interfaces, where the silicon and the biological targets have matched properties. We focused on light-induced processes at these interfaces, and developed a set of matrices to quantify and differentiate the capacitive, Faradaic and thermal outputs from about 30 different silicon materials in saline. We show that these interfaces are useful for the light-controlled non-genetic modulation of intracellular calcium dynamics, of cytoskeletal structures and transport, of cellular excitability, of neurotransmitter release from brain slices, and of brain activity in vivo.
Collapse
Affiliation(s)
- Yuanwen Jiang
- Department of Chemistry, University of Chicago, Chicago, IL, USA
- The James Franck Institute, University of Chicago, Chicago, IL, USA
| | - Xiaojian Li
- Department of Physiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Bing Liu
- Department of Neurobiology, University of Chicago, Chicago, IL, USA
| | - Jaeseok Yi
- Department of Chemistry, University of Chicago, Chicago, IL, USA
- The James Franck Institute, University of Chicago, Chicago, IL, USA
| | - Yin Fang
- The James Franck Institute, University of Chicago, Chicago, IL, USA
| | - Fengyuan Shi
- The Research Resources Center, University of Illinois at Chicago, Chicago, IL, USA
| | - Xiang Gao
- The James Franck Institute, University of Chicago, Chicago, IL, USA
| | | | - Ramya Parameswaran
- The Graduate Program in Biophysical Sciences, University of Chicago, Chicago, IL, USA
| | - Kelliann Koehler
- Department of Chemistry, University of Chicago, Chicago, IL, USA
- The James Franck Institute, University of Chicago, Chicago, IL, USA
| | - Vishnu Nair
- Department of Chemistry, University of Chicago, Chicago, IL, USA
- The James Franck Institute, University of Chicago, Chicago, IL, USA
| | - Jiping Yue
- Ben May Department for Cancer Research, University of Chicago, Chicago, IL, USA
| | - KuangHua Guo
- Department of Physiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Yin Fang
- Department of Chemistry, University of Chicago, Chicago, IL, USA
| | - Hsiu-Ming Tsai
- Department of Radiology, University of Chicago, Chicago, IL, USA
| | | | - Raymond C S Wong
- University Research Facility in Behavioral and Systems Neuroscience (UBSN), Hong Kong Polytechnic University, Kowloon, Hong Kong
| | - Chien-Min Kao
- Department of Radiology, University of Chicago, Chicago, IL, USA
| | - Chin-Tu Chen
- Department of Radiology, University of Chicago, Chicago, IL, USA
| | - Alan W Nicholls
- The Research Resources Center, University of Illinois at Chicago, Chicago, IL, USA
| | - Xiaoyang Wu
- Ben May Department for Cancer Research, University of Chicago, Chicago, IL, USA
| | - Gordon M G Shepherd
- Department of Physiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Bozhi Tian
- Department of Chemistry, University of Chicago, Chicago, IL, USA.
- The James Franck Institute, University of Chicago, Chicago, IL, USA.
- The Institute for Biophysical Dynamics, Chicago, IL, USA.
| |
Collapse
|
295
|
Xu L, Zhao Y, Owusu KA, Zhuang Z, Liu Q, Wang Z, Li Z, Mai L. Recent Advances in Nanowire-Biosystem Interfaces: From Chemical Conversion, Energy Production to Electrophysiology. Chem 2018. [DOI: 10.1016/j.chempr.2018.04.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
296
|
Tang L, Cheng S, Zhang L, Mi H, Mou L, Yang S, Huang Z, Shi X, Jiang X. Printable Metal-Polymer Conductors for Highly Stretchable Bio-Devices. iScience 2018; 4:302-311. [PMID: 30240749 PMCID: PMC6146547 DOI: 10.1016/j.isci.2018.05.013] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 04/30/2018] [Accepted: 05/01/2018] [Indexed: 11/27/2022] Open
Abstract
Stretchable, biocompatible devices can bridge electronics and biology. However, most stretchable conductors for such devices are toxic, costly, and regularly break/degrade after several large deformations. Here we show printable, highly stretchable, and biocompatible metal-polymer conductors by casting and peeling off polymers from patterned liquid metal particles, forming surface-embedded metal in polymeric hosts. Our printable conductors present good stretchability (2,316 S/cm at a strain of 500%) and repeatability (ΔR/R <3% after 10,000 cycles), which can satisfy most electrical applications in extreme deformations. This strategy not only overcomes large surface tension of liquid metal but also avoids the undesirable sintering of its particles by stress in deformations, such that stretchable conductors can form on various substrates with high resolution (15 μm), high throughput (∼2,000 samples/hour), and low cost (one-quarter price of silver). We use these conductors for stretchable circuits, motion sensors, wearable glove keyboards, and electroporation of live cells. A straightforward method for sintering liquid metal particles with high efficiency Liquid metal can be patterned on different substrates with high resolution Low-cost, high-throughput, stretchable printed conductors can be fabricated Conductors are biocompatible and have potentials in implantable electronics
Collapse
Affiliation(s)
- Lixue Tang
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, P. R. China; University of Chinese Academy of Sciences, 19 A Yuquan Road, Shijingshan District, Beijing 100049, P. R. China
| | - Shiyu Cheng
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, P. R. China; University of Chinese Academy of Sciences, 19 A Yuquan Road, Shijingshan District, Beijing 100049, P. R. China
| | - Luyao Zhang
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, P. R. China; University of Chinese Academy of Sciences, 19 A Yuquan Road, Shijingshan District, Beijing 100049, P. R. China; State Key Laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, P. R. China
| | - Hanbing Mi
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, P. R. China; University of Chinese Academy of Sciences, 19 A Yuquan Road, Shijingshan District, Beijing 100049, P. R. China
| | - Lei Mou
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, P. R. China; University of Chinese Academy of Sciences, 19 A Yuquan Road, Shijingshan District, Beijing 100049, P. R. China
| | - Shuaijian Yang
- University of Chinese Academy of Sciences, 19 A Yuquan Road, Shijingshan District, Beijing 100049, P. R. China
| | - Zhiwei Huang
- University of Chinese Academy of Sciences, 19 A Yuquan Road, Shijingshan District, Beijing 100049, P. R. China
| | - Xinghua Shi
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, P. R. China; University of Chinese Academy of Sciences, 19 A Yuquan Road, Shijingshan District, Beijing 100049, P. R. China
| | - Xingyu Jiang
- Beijing Engineering Research Center for BioNanotechnology and CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for NanoScience and Technology, No. 11 Zhongguancun Beiyitiao, Beijing 100190, P. R. China; University of Chinese Academy of Sciences, 19 A Yuquan Road, Shijingshan District, Beijing 100049, P. R. China.
| |
Collapse
|
297
|
Soft transparent graphene contact lens electrodes for conformal full-cornea recording of electroretinogram. Nat Commun 2018; 9:2334. [PMID: 29899545 PMCID: PMC5998030 DOI: 10.1038/s41467-018-04781-w] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Accepted: 05/18/2018] [Indexed: 01/23/2023] Open
Abstract
Visual electrophysiology measurements are important for ophthalmic diagnostic testing. Electrodes with combined optical transparency and softness are highly desirable, and sometimes indispensable for many ocular electrophysiology measurements. Here we report the fabrication of soft graphene contact lens electrodes (GRACEs) with broad-spectrum optical transparency, and their application in conformal, full-cornea recording of electroretinography (ERG) from cynomolgus monkeys. The GRACEs give higher signal amplitude than conventional ERG electrodes in recordings of various full-field ERG responses. High-quality topographic mapping of multifocal ERG under simultaneous fundus monitoring is realized. A conformal and tight interface between the GRACEs and cornea is revealed. Neither corneal irritation nor abnormal behavior of the animals is observed after ERG measurements with GRACEs. Furthermore, spatially resolved ERG recordings on rabbits with graphene multi-electrode array reveal a stronger signal at the central cornea than the periphery. These results demonstrate the unique capabilities of the graphene-based electrodes for in vivo visual electrophysiology studies.
Collapse
|
298
|
Luo Z, Weiss DE, Liu Q, Tian B. Biomimetic Approaches Toward Smart Bio-hybrid Systems. NANO RESEARCH 2018; 11:3009-3030. [PMID: 30906509 PMCID: PMC6430233 DOI: 10.1007/s12274-018-2004-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Revised: 01/21/2018] [Accepted: 01/23/2018] [Indexed: 05/30/2023]
Abstract
Bio-integrated materials and devices can blur the interfaces between living and artificial systems. Microfluidics, bioelectronics and engineered nanostructures, with close interactions with biology at the cellular or tissue levels, have already yielded a spectrum of new applications. Many new designs emerge, including those of organ-on-a-chip systems, biodegradable implants, electroceutical devices, minimally invasive neuro-prosthetic tools, and soft robotics. In this review, we highlight a few recent advances on the fabrication and application of the smart bio-hybrid systems, with a particular emphasis on the three-dimensional (3D) bio-integrated devices that mimick the 3D feature of tissue scaffolds. Moreover, neurons integrated with engineered nanostructures for wireless neuromodulation and dynamic neural output will be briefly discussed. We will also go over the progress in the construction of cell-enabled soft robotics, where a tight coupling of the synthetic and biological parts is crucial for efficient functions. Finally, we summarize the approaches for enhancing bio-integration with biomimetic micro- and nanostructures.
Collapse
Affiliation(s)
- Zhiqiang Luo
- College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074, PR China
| | - Dara E. Weiss
- Department of Chemistry, The University of Chicago, Chicago, IL 60637, USA
| | - Qingyun Liu
- College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074, PR China
| | - Bozhi Tian
- Department of Chemistry, The University of Chicago, Chicago, IL 60637, USA
- The James Franck Institute, The University of Chicago, Chicago, IL 60637, USA
- The Institute for Biophysical Dynamics, The University of Chicago, Chicago, IL 60637, USA
| |
Collapse
|
299
|
Hong G, Yang X, Zhou T, Lieber CM. Mesh electronics: a new paradigm for tissue-like brain probes. Curr Opin Neurobiol 2018; 50:33-41. [PMID: 29202327 PMCID: PMC5984112 DOI: 10.1016/j.conb.2017.11.007] [Citation(s) in RCA: 82] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2017] [Revised: 10/21/2017] [Accepted: 11/18/2017] [Indexed: 01/10/2023]
Abstract
Existing implantable neurotechnologies for understanding the brain and treating neurological diseases have intrinsic properties that have limited their capability to achieve chronically-stable brain interfaces with single-neuron spatiotemporal resolution. These limitations reflect what has been dichotomy between the structure and mechanical properties of living brain tissue and non-living neural probes. To bridge the gap between neural and electronic networks, we have introduced the new concept of mesh electronics probes designed with structural and mechanical properties such that the implant begins to 'look and behave' like neural tissue. Syringe-implanted mesh electronics have led to the realization of probes that are neuro-attractive and free of the chronic immune response, as well as capable of stable long-term mapping and modulation of brain activity at the single-neuron level. This review provides a historical overview of a 10-year development of mesh electronics by highlighting the tissue-like design, syringe-assisted delivery, seamless neural tissue integration, and single-neuron level chronic recording stability of mesh electronics. We also offer insights on unique near-term opportunities and future directions for neuroscience and neurology that now are available or expected for mesh electronics neurotechnologies.
Collapse
Affiliation(s)
- Guosong Hong
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA 02138, USA
| | - Xiao Yang
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA 02138, USA
| | - Tao Zhou
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA 02138, USA
| | - Charles M Lieber
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA 02138, USA; John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA.
| |
Collapse
|
300
|
Shoffstall AJ, Capadona JR. Bioinspired materials and systems for neural interfacing. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2018. [DOI: 10.1016/j.cobme.2018.05.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|